HomeMy WebLinkAboutPermit EL08-0540 - WESTFIELD SOUTHCENTER MALL - BEN & JERRY'SBEN & JERRY'S 2800 SC MALL K 2688 07 -23-08 ELO8-5 40 Parcel No.: Address: Suite No: CitAlbf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT 6364200010 2800 SOUTHCENTER MALL TUKW Permit Number: EL08 -540 Issue Date: 07/01/2008 Permit Expires On: 12/28/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: BEN & JERRY'S 2800 SOUTHCENTER MALL K2688 , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA RHETT RUSSELL 5508 OYSTER BAY RD , OLYMPIA WA HOLMES ELECTRIC CO Address: PO BOX 179 , RENTON WA Contractor License No: HOLMEEC549BH Phone: Phone: 360 - 970 -6849 Phone: (425)255 -8666 Expiration Date: 10/31/2008 DESCRIPTION OF WORK: ALL ELECTRICAL WORK FOR NEW KIOSK Value of Electrical: $4,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: J91'11 $238.00 2005 Date: - 1 Q O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does no,r,tpresume to give authority to violate or cancel the provisions of any other state or local laws regulating construction performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: 11,1&e7 7 C 7-k -Z Date: T 1"9g--- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -540 Printed: 07 -01 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Permit Number: EL08 -540 Address: 2800 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 05/09/2008 Tenant: BEN & JERRY'S Issue Date: 07/01/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p - ormance of work. Signature: ALIA n-ho-7,9075K' Print Name: Date: doc: Cond -Elec EL08 -540 Printed: 07 -01 -2008 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. PLO g- 81-(0 Project No. ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 6 3 442it, UU /Q Site Address: 26 & Jbe1 It e-,,-,)k- 4_KZZai Suite Number: Tenant Name: , fir, 1 .1e-rr y '.5 New Tenant: Property Owners Name: 1 t)e, ' A' Y' /' d ,)y^ap n-.4 A /--,—► Mailing Address://(O/ k1, /5/7,/'e & 04 1 //''' -41 LeS Ai? ietPS City LI CONTACT PERSON - Who do we contact when your permit is ready to be issued Floor: Ycs ❑..No State 1b ,62S Zip -(4.c) 576 -- (06g Nance: Rh e A2/4 6.5 1 Day Telephone. Mailing Address: Address: S56c9 riai 3eLly Fax Number: 6 a7. (/1 7;A— 9 c52 Cit State %rp E -Mail Address: t h e rk55e 4 e- 0, -,14`S- • /7 el- ELECTRICAL CONTRACTOR INFORMATION Company Natne: .. ~r Mailing Address:__ Contact Person: E -Mail Address: Contractor Registration Number: City State Zip Day Telephone: Fax Number: Expiration Date: Valuation of Project (contractor's hid price): S 06O • o U Scope of Work (please provide detailed information): Ali e/e ,-,_,(1 /)n -�k A• - ,V j Will service be altered? Type of L'se: Type of work: 2/New ❑ Low Voltage Property Served by: Euget Sound Energy ❑ Seattle City Light ❑ Ycs Addition Generator VN0 ❑ Service Change ❑ Fire Alarm II :Appl aunn. \I nrm,•AppIrkario i. 1111 I n1c :4 :nn7 l.kc:rr al ' ,ui �pphcaunn 2.11. hh Adding more than 50 amps? ❑ Yes IF/No ❑ Remodel ❑ Tenant Improvement El Telecommunication ❑ Temporary Service Page I of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single fancily dwellings S140.00 (including an attachcd garage) ❑ Garages, pools. spas and outbuildings $75.00 ca ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ca RESIDENTIAL REMODEL, AND SERVICE CHANGES ❑ Service change or alteration S75.00 (no addedaltcrcd circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits - -- - -- - -- $10.00 ea ❑ Circuits added /altered without service change S50.00 (up to 5 circuits) ❑ Circuits added /altered without scrvlce change $50.00 (6 or more circuits) $7.00 ea ❑ Mctcr %mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI - FAMILY AND COMMERCIAL Fees are based on the valliat.lon of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ Temporary service (generator) S75.00 ❑ Manufactured/mobile home service S80.00 (excluding garage or outbuilding) ❑ Carnivals - - 575.00 Number of concessions $10.00 ea Value of Construction In all cases, a value of construction amount should he entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TIIIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PFNAI.TY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. ANi) I AM AUTHORIZED TO APPLY FOR THiS PERMIT. BUILDING OWNER OR ELECTRICAL. CONTRACTOR: Signature: jr1/4"C 4 Print Name: �J'R4 A • /2 ,,SSt l Mailing Address: cs'Oe op. Day Telephone: a(,2,b City Date: 570) (31'°) 1‘70 Code /t 4- ceico2_ State Zip Date Application Accepted: 5_q.,0 P/ Date Application Expires: `l-4 -- g Staff Initials: tmk. 11 ApplwanonF•.1'nmu- Appli,anon> On 1 in: 4 :Ills' 1 :;, n-,1 1'cmn \pplicmnon .io, hh Page 2of2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -540 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/09/2008 Applicant: BEN & JERRY'S Issue Date: Receipt No.: R08 -02343 Payment Amount: $58.00 Initials: WER Payment Date: 07/01/2008 09:08 AM User ID: 1655 Balance: $0.00 Payee: HOLMES ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 046546 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 4298 07/01 9711 TOTAL 58.00 dot: Receipt -06 Printed: 07 -01 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -02304 Initials: WER User ID: 1655 Payee: RHETT RUSSELL Payment Date: 06/25/2008 Total Payment: 948.10 SET ID: 0625 SET NAME: BEN & JERRYS SET TRANSACTIONS: Set Member Amount D08 -269 636.50 ET�O'8 =540 144.00 G08 -147 167.60 TOTAL: 948.10 TRANSACTION LIST: Type Method Description Amount Payment Check 5139 948.10 TOTAL: 948.10 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR PLUMBING - NONRES STATE BUILDING SURCHARGE 000/322.100 632.00 000.322.101.00.0 144.00 000.322.103.00.0 167.60 000/386.904 4.50 TOTAL: 948.10 4122 06/25 9711 TOTAL 948.10 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -540 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/09/2008 Applicant: BEN & JERRY'S Issue Date: Receipt No.: R08 -01540 Initials: WER User ID: 1655 Payment Amount: $36.00 Payment Date: 05/09/2008 11:24 AM Balance: $144.00 Payee: RHETT RUSSELL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5127 36.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 36.00 Total: $36.00 2208 05/09 9711 TOTAL 475.80 t'") doc: Receiot -06 Printed: 05-09 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit aog -Cra p PERMIT NO. (206)431- Project: 664 �� +� Type of Inspection: Z( Address: Tgo Q titeivt„ Date Called: Special Instructions: Date Wanted: 7/Z3 <..: p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. CO MENTS: Inspector: 51.A 66.44;c Date: 01 12, 5/IA El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: . �•- y.�. INSPECTION RECORD Retain a copy with permit aa- 9/o PERMIT NO CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 INSPECTION NO. Project: �J �� • , Jam`' d' ae. Type of Inspection: D� Address: /4 Date Called: Special Instructions: Date Wanted: /�� // a.m. p.m. Requester: S-, alb Phone No: Approved per applicable codes. , Corrections required prior to approval. COMMENTS: D-g_ - 9-0c, S-, alb Noit - &4P „°T' TD Col. -p �ELir'Gti rn(Av Inspector: � 6446)c, Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. c�J +� CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4-""1 f S _. ."° Type of Inspection: O —]o l c Address: � Date Called: Special Instructions: Date Wanted: j 'V/ p Requester: Phone No: . fJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: D-K AU/ Cog-f\ /\) . Q04.1+ I 'Inspector: 6c-rvAkir, 'Date: 111(10 ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit Pip PERMIT PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: if-ff i 1,i I� Type of Inspection: 7002..--- Address: 2.4, Date Called: Special Instructions: Date Wanted: , S a:m m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 5t icE IInsPector:,fID 6641/16(1N $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: a7 /1s f bf Receipt No.: !Date: S- RivI1T COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -540 DATE: 06 -25 -08 PROJECT NAME: BEN & JERRY'S SITE ADDRESS: 2600 SOUTHCENTER MALL, K -2688 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Bui ding Division Public Works .l1 Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 06-26-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS R CORRECTIONS: Approved Notation: DUE DATE: 07-24-08 Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 *PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL08 -540 DATE: 05 -09 -08 PROJECT NAME: BEN & JERRY'S SITE ADDRESS: 2800 SOUTHCENTER MALL - K2688 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 6-08 Bul °Idlfig 'vision Public Works n Fire Prevention n Structural Planning Division n Permit Coordinator C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-1 3 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06 -1 0-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing sltp.doc 2 -28 -02 • PROJECT NAME: MA 'III So�, ` SITE ADDRESS: (� , M t witiSS • PERMIT NO: arOi `9- 0 ORIGINAL ISSUE DATE: t4 IA" REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 0(/.2 ' OTi 1-6v■ -1- I -l18' UqQ, Summary of Revision: CAUIMig}..1"C1iL GN% pylwir C`v Foy Cof l a-m - Received by(lAtto c EC/\x5 A REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (.10.5\0c. Plan Check/Permit Number: 1A) 4 -silo ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # NRevision # , after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner yry VILA JUN 2 5 2008 PERMIT CENTEF, Project Name: Project Address: 2.12,00 SLan\C L1(l AAZEO9- Contact Person )V1 CO C ( ,` Phone Number: On�€-Q- 07! 1 4362 (.069/ Summary of Revision: S c_1\oiNu'1..C►N3 r -x t3 So�'Mix -w iD elf ckit.uk - \->ekk C LUs Co E Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 61(2G0 ■applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electrician or Plumber License Detail 1 • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the fu-m or a full -time supervisory employee. License Information License HOLMEEC549BH Licensee Name HOLMES ELECTRIC CO Licensee Type ELECTRICAL CONTRACTOR UB1 177003752 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 179 Address 2 City RENTON County KING State WA Zip 98057 Phone 4252558666 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/8/1946 Expiration Date 10/31/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License RICHAM *178LZ Electrical Administrator Information License RICHAM* 178LZ Name RICHARDS, MICHAEL Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date RICHARDS, MICHAEL W 01/01/1980 RICHARDS, EUGENE M 01/01/1980 HOLMES, MICHAEL J 01/01/1980 HOLMES, JERAY A AGENT 01/01/1980 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= HOLMEEC549BH 07/01/2008 D�D j SSE 2600 SOUTHCENTER SEATTLE, WA 98188 PERMIT SET 108-043 FRANCHISEE ICE CREAM AND DESSERTS, LLC 5508 OYSTER BAY ROAD NW OLYMPIA, WA CONTACT: RHETT RU55ELL Pi IQNE: (877) 333 - 4791 FAX • (360) 252 -8829 ARCHITECT HELIX DESIGN GROUP 6021 12th STREET EAST SUITE 201 TACOMA, WASHINGTON 98424 CONTACT: BRUCE MCKEAN PHONE: (253) 922 -9037 FAX: (253) 922_,499 INTERIORS HELIX DESIGN GROUP 6021 12th STREET EAST SUITE 201 TACOMA, WASHINGTON 98424 CONTACT: EMILY WOLD DIANE BARRINGER PHONE: (253) 922 -1037 FAX: (253) 922 -6499 BEN JERRY'S CONSTRUCTION MANAGER RETAIL CONSTRUCTION MANAGER 2916 IRIS MEADOW DRIVE RIVERTON, UT 84065 CONTACT: MIKE ANDRUS PHONE: (801) 253 -4443 MECHANICAL ENGINEER HULTZ /BHU /CROSS INC. 2407 NORTH 31st STREET STE200 TACOMA, WASHINGTON 95407 CONTACT: RICK I- ULT7 PHONE: (253) 353 -3257 FAX: (253) 3833283 SITE PLAN FUTURE RETAIL BEARS THREE LEVELS 174,630e iffe\ NORTH OJECT LOCATION SITE #9250 LEVEL 2 OF 3 N.T.S. ELECTRICAL ENGINEER HULTZ/B1-1U /CR055 INC. 2407 NORTH 31st STREET STE.200 TACOMA, WASHINGTON 98407 CONTACT: BRAD HALL Pa -IONE: (253) 383 -32557 FAX: (253) 383 -3283 VICINITY MAP NORTH N.T.S. GENERAL NOTES 1. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES: WHERE MORE THAN ONE CODE OR ORDINANCE CONFLICT WITH EACH OTHER, THE MORE RESTRICTIVE CODE SHALL GOVERN. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE 51TE AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY UNCERTAINTIES OR DISCREPANCIES WITH DRAWINGS. 3. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AT THE SITE, PROTECT THEM FROM DAMAGE AND REPORT ANY DISCREPANCIES WITH DRAWINGS. 4. THE CONTRACTOR SHALL INSURE THE HEALTH AND SAFETY OF THE PUBLIC AND ALL 141-12 ENTER THE BUILDING DURING CONSTRUCTION. 5. THE CONTRACTOR 51-IALL VERIFY AND COORDINATE THE WORK OF SUBCONTRACTORS AND ALL DRAWINGS PRIOR TO PROCEEDING WJTL -I ANY WORK OR FABRICATION. 6, DRAWINGS SHALL NOT BE SCALED, NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS, 7. NOT USED 13. DIMENSIONS 014 PLANS ARE TO FACE OF STUD, CENTER OF COLUMN, CENTER OF MULLION OR FACE OF CONCRETE. UNLESS OTI- IERWISE NOTED. 9. NOT USED 10. REPAIR/REPLACE EXISTING WALL, • FLOOR, AND CEILING FINISHES TO MATCH EXISTING ADJACENT FINISHES WHEN DAMAGED DURING COURSE OF CONSTRUCTION. II, DEMOLISH ALL EXISTING BUILDING COMPONENTS NECESSART TO CONSTRUCT WORK. CAP ALL EXISTING UTILITIES (PLUMBING, ELECTRICAL, AND MECHANICAL) BEHIND WALES, FLOORS, ETC. 12. NOT USED SHEET INDEX GENERAL DRAWINGS G001 COVER SHEET ARCHITECTURAL DRAWINGS A100 FLOOR PLAN, EQUIPMENT PLAN # SCHEDULES A6O0 ELEVATIONS A6OI ELEVATIONS, SECTIONS DETAILS A602 DETAILS MECHANICAL DRAWINGS MI.0 MECHANICAL LEGEND, NOTES 4 SCHEDULES M2.0 PLUMBING PLANS 4 DETAILS ELECTRICAL DRAWINGS E100 ELECTRICAL PLANS # SCHEDULES E200 ELECTRICAL SPECIFICATIONS FILE COPY Permit No. . Mar review approval is subject to errors and moons. Approval of construction documents does not atthorize the violation of any adopted cue or ordinance. Rei ipt of approved Field and coedit:ins is acknowledged: City of Tukwila BUILDING DIVISION PROJECT INFORMATION GOVERNING CODE OCCUPANCY GROUPS IBC CHAPTER 3 CONSTRUCTION TYPE IBC TABLE 503 ALLOWABLE FLOOR AREA IBC TABLE 503 TOTAL FIRE SPRINKLERS IBC CHAPTER 9 FIRE ALARM AND SMOKE DETECTION 1BC CHAPTER q 20% INTERNATIONAL BUILDING CODE A -2 - RESTAURANT 1113 FULLY SPRINKLERED 180 5Q. FT. ALL INTERIOR SPACES SHALL SE PROTECTED BY AN AUTOMATIC FIRE SPRINKLER SYSTEM ALL INTERIOR SPACES SHALL BE PROTECTED BY AN AUTOMATIC SMOKE DETECTION AND FIRE ALARM SYSTEM 141TH A MUNICIPAL TRIP CIRCUIT 'SEPARATE PERMIT REQUIRED FOR: l Mechanical RElectrical Plumbing ®(Gas Piping City of Tukwila BUILDING DIVISION SYMBOLS BUILDING SECTION SECTION LETTER SHEET NUMBER WALL SECTION SECTION NUMBER SHEET NUMBER GRID LINE DESIGNATION c.o.s.. center of structure F.0,5. = face of structure (E) : existing DETAIL DETAIL NUMBER 51-IF_ET NUMBER REVISION REVISION MATCI -1LINE NORTH ARROW A MATCHLINE ®I Mil I®lIMI NORTH RECEIVED CITY OF TUKWILA JUN 2 5 2008 PERMIT CENTER REVISION N0. i fo°trg4o REVISIONS y No changes shall be made to the scope of work without prior approval of Tukwila Building Division. BATE: Revisions will require a new plan submittal and may include additional plan review fens. Helix sign g rou p AMERICAN INSTITUTE OF ARCHITECTS REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC JUN 3 0 2008 / Of ! kwila B ILDIN 1 ION BEN & JERRY'S KIOSK SOUTHCENTER MALL SEATTLE , WA REVISION DATE DATE 05.01.08 JOB N0. i08 -043 PERMIT SET G001 DRAINING NO, 1 of 9 © HELIX DESIGN GROUP: ALL RIGHTS RESERVED. No port of this dooumert rnoy be repredred 'n mry ions or by uny meDrrs uthoul perrnissien fn w1ifo from Hefa Deign Group 1 3 4 5 6 7 8 9 z eri .m A FLOOR PLAN LEGEND .......,_ DESCRIPTION 1 SQL AND TEXT GATE INTERIOR ELEVATION elevation number sheet number BUILDING SECTION section number sheet number NALL SE�.TION section number .. / /,/ Ott / /// t /// t jr . it 1 k1 / tits` 10A L _ . r � /t 1 3A BA 7A :. SIM IOA ._. 1TP 1f SIM i 10 1. sheet number FIRE EXTINGUISHER semi- recess cabinet, rated cabinet at rated walls CORIAN TIP • 0, F.E. WALL TYPES .......,_ DESCRIPTION SYMBOL AND TEXT WALL TYPE I 3 5/6" METAL. STUDS 41 16" O.C. 6" METAL STUDS Ili° 0.C. GATE, SEE ELEVATIONS 4 DETAIL IO1-1/A6O2 1 3/4"4 GROMMETS TO BE FIELD LOCATED, BASED ON EQUIPMENT LOCATIONS. COORD W/ ARCH. 4 ELEC. DIGS. FXISITING FLOORING COLOR 1 PATTERN / TYPE NOTES . @ CORIAN SHEET NOTES GC SYMBOL NOTE FOI F02 F03 GATE, SEE ELEVATIONS 4 DETAIL IO1-1/A6O2 1 3/4"4 GROMMETS TO BE FIELD LOCATED, BASED ON EQUIPMENT LOCATIONS. COORD W/ ARCH. 4 ELEC. DIGS. FXISITING FLOORING A B c D E STA DARD ABBR±V ATON5 ACT ADJ ALUM AWE BB BD BLKG BOT CAB GB c_ CLR CER CI-IRL CLG CMU CONC COORD C.O.S. CPT CT (a) DBL D.F. DN ACOUSTICAL CEILING TILE ADJUSTABLE ALUMINUM ACOUSTICAL WALL FABRIC BACKERBOARD BOARD BLOCKING BOTTOM COMPACT CABINET CHALKBOARD CENTER LINE CLEAR CERAMIC CHAIR RAIL CEILING CRETE MASONRY UNIT CONCRETE COORDINATE CENTER OF STRUCTURE CARPET CERAMIC TILE DEPTH DEMOLtSH DOUBLE DRINKING FOUNTAIN DOWN D.S. DOWNSPOUT DW DISHWASHER EA EACH EL. ELEVATION E.P. ELECTRICAL PANEL EQ EQUAL EQUIP EQUIPMENT (E) EXISTING EXT EXTERIOR FF FACTORY FINISH FIN FINIS1-1 H.C. FURNISHED AND INSTALLED BY CONTRACTOR FJ.O. FURNISHED AND INSTALLED BY OWNER FLR FLOOR F.O.I.C. FURNISHED BY OWNER INSTALLED BY CONTRACTOR F.0.5. FACE OF STRUCTURE FP FIREPROOFING F.P. FLAG POLE F.D. FLOOR DRAIN F.E. FIRE EXTINGUISHER F.H. FIRE HYDRANT FT FEET / FOOT (F) FUTURE GALV GALVANIZED GB GRAB BAR GFRG GLASS FIBER REINFORCED Gypsum GL GLASS GLB GLUE LAMINATED BEAM GWB GYPSUM WALLBOARD GYP GYPSUM 14 WEIGHT 1-IB HORIZONTAL BLIND H.B. NOSE BIB I-1C HOLLOW CORE 1I.G, HANDICAPPED I-IM HOLLOW METAL HOR HORIZONTAL I-IR HOUR 111 HEIGHT T INT INTERIOR JAN JANITOR JT JOINT LBS POUNDS (WEIGHT) LG LAMINATED GLASS LIN LINOLEUM MAS MASONRY MAX MAXIMUM MB MARKERBOARD MDF MEDIUM DENSITY FIBERBOARD MIN MINIMUM MIN. MINUTE MTL. N.I.C. NO. N.T.5, D.C. O.1-L OPNG DPP PFT PLAM PLY P5 PT QT (R) RB REF READ RF 5 (S) 5C SCI-4D SDT 5G 511.1 METAL NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OVERHEAD OPENING OPPOSITE PORCELAIN FLOOR TILE PLASTIC LAMINATE PLYWOOD PROJECTION SCREEN PAINT QUARRY TILE RADIUS RELOCATED RUBBER BASE RErRIGERATOR REQUIRED RUBBER FLOORING SOUND SALVAGED SOLID CORE SCHEDULE STATIC DISSIPATED TILE SAFETY GLASS SIMILAR SLR 55 5TL 5V TB TBB TNK T.O.B. T.O.F.. TRTD T.5. TNF TYP U.N.Q. UNFIN VCT VP WI WAIN WB WD WG WH N/O NON WP SEALER STAINLESS STEEL STEEL SHEET VINYL TACKBOARD TILE BACKERBDARD TI -TICK TOP OF BEARING TOP OF FLOOR TREATED TUBE STEEL TACKABLE NALL FABRIC TYPICAL UNLESS NOTED OTHERWISE UNFINISHED VINYL COMPOSITION TILE VENEER PLASTER WIDTH WITfd WAINSCOT WHITEBOARD WOOD WIRE GLASS WATER HEATER WITHOUT WALK OFF MAT WORK POINT COLORS AND MATERIALS SCHEDULE . GC SC1DULE SYMBOL MATERIAL MANUFACTURER COLOR 1 PATTERN / TYPE NOTES . C -I CORIAN DUPONT NOCTURNE <2J G -2 CQRIAN DUPONT GLACIER ICE <2> 'MIL METAL - MATCH FORMICA COLOR - SPRINGTIME / SMOOTH FINISH C3> T -I GLASS TILE . UNITED TILE - INTERSTYLE COBBLETONES - HARVEST Inc Lia C0j 3 T -2 GLASS TILE UNITED TILE - INTERSTYLE - COBBLErONE5 - FOREST 55 STAINLESS STEEL _ - . - GV GRAPHIC VINLY KORO GRAPHICS - <I> - - 111010 0 GC GC 2 DIP CASE COLORS AND MATERIALS SCHEDULE NOTES <1> CONSULT WITH OWNER, SE COLORED RENDERINGS FOR INTENT . <2> SQUARE EDGE PROFILE <3> PROVIDE TENANT WITH SAMPLE BEFORE ORDERING $ INSTALLATION a qE IS' -0° Tri IOf E.. // /, r/ // ▪ / / m cn FLOOR PLAN 31 -0" /l % / /f/ / / //� '/ l /II /�! l�f / / /f! /% % l f / / /! /I / /lam // // / //� / ► i f i' i * i, i 0 —e 0 0 1 f 0 00 ✓ ▪ - 7A 3A 5' qd F�3 F.E. 4E SCALE: 'I /2 " -I' -0" B D E F G H J K IE0UP'T GC SC1DULE 0 30 0 0 0 0 0 0 PROVIDED BY INSTALLED BY 1 CONNECTED BY 1 ITEM NO. Q DESCRIPTION MANUFACTURER PART NUMBER EQUIP SIZE ELECTRICAL PLUMBING _ z o E CONNECT • az lY 1 LU A LU = IVOLTS 1 .z Q_ a_ = 4 : E < GC 1 COLD WATER Inc Lia C0j 3 WASTE 0 GC GC 0 30 0 0 0 0 0 0 2 WAFFLE CONE MAKER CABATCO INC. MD -1055E 10,25" 19" 11" 120 1 1/3 1200 - 60 - - - 24" SERVICE CORD WITH PLUG 0 ( I E ) 0 GC - 1 MENU BOARD PROVIDED BY OWNER - _ _ - .. - - - .. - - 111010 0 GC GC 2 DIP CASE MASTER BILT DD -69L 6cI" 27.5'150.25' 120 I 1/3 - 3.1 60 - - - I5A CORD W1T1 -1 NEMA 5 -15P - iiiED 0 MC MC 7- 1 DIPPER WELL DIPWELLL W, 15" HALF NOON 15" 5" 6" - - . _ r _ - ..5I - .1.5" - - 0 0 0 O I CASH REGISTER MICRO SYSTEM ECLIPSE - - - - _ - - - - - - - 0 - 0 41E111 0 MC MC I HQT WATER TAMK _ . - _ - - - - - _ 0 _ (9E) 0 MC MC 1 ICE MAKER WITH BIN MANITOWOC QM - 45 115 1 1/4 • - 5.3 60 3/8" - I" - 15A CORD WIT1 -I NEMA 55 -15P - -r fr GC MC MC I DROP -IN STAINLESS STEEL HAND SINK ADV. TABCO DI- I -IQ -2X 10" 14" 10" - - - - - - .5" 1.5" 1.5" - WITH FAUCET AND BASKET (12E) 0 0 0 2 BLENDER VITA -MIX 36010 - - - 115 I 3 - 15 60 - - - 0 SERVICE CORD WITH PLUG - 14E 0 EC EC 1 UNDEI2CQUNTER REFRIGERATOR TRUE MANUFACTURING TUC- 36 -- ADA 36- ,I 30- " 29- u 115 , I 1/5 - 4.0 60 - - - 24" I5A CORD WITH NEMA 5 -I5P 0 0 EC EC 16E I UNDERCOUNTER FREEZER TRUE MANUFACTURING TUC -- 36 - F - ADA 36- " i 3Q- ° 2 - 9 115 1 1/5 - 4.0 lip - - - 2A" I5A CORD WITH NEMA S--ISP 6 0 EC EC I FUDGE WARMER SERVER PRODUCTS 85810 - - - 120 1 - 415 - 60 - - - - SERVICE CORD WITH PLUG - alli 0 EC EC I WAFFLE DIP WARMER SERVER PRODUCTS 92000 - - -- 120 1 - 100 - 60 - - - - SERVICE CORD W1T1-1 PLUG - [18E) 0 0 0 I DIGITAL SCALE TOSHIBA TEC SL -2200 13.3" 13.4 5.4" 115 1 - - - 60 - - - - SERVICE CORD WITH PLUG - 19E GC MC MC 1 STAINLESS STEEL 3 -BAY SINK ADV. TABCO K7-C2-21 75 „ 21 21" 36.5 „ -- - - - - -- .75 " .75 " I,5 „ _ ` 1 FAUCET, 3 TWIST WASTE VALVES - 25E 0 GC GC 1 • WAFFLE CONE SHELF INST. EQUIP, INC. _ _ _ .. _ -. _ . _ _ _ _ _ - 0 GC GC 5 CUP DISPENSER DISPENSE -RITE . - - - - - - - - - - - - - S.S. 304 SERIES ( CO 0 J 0 - C42E) I CONE BOX INST. EQUIP. INC, 211'1 _ _ - _ _ . _ - - . - _ - _ - _ — 0 0 - 1 , SPLASH GUARD - _ - _ - - OWNER - - V -- - VENDER _ - _ - - _ J 20M 1 GC — GENERAL CONTRACTOR EC - ELECTRICAL CONTRACTOR MC - MECHANICAL CONTRACTOR 0 SCHEDULE 'NOTES NATIONAL EQUIPMENT/MILLWORK SUPPLIES 0 30 0 0 0 0 0 0 NITi4 CONE ROLLER STUB UP IA1IT --I INSTALLATION KIT WITH DSL PRINTER DRAWER AND RELATED 1- IARDWARE 5.5. 304 SERIES WITH CASTERS NOT USED . NOT USED HAND SINK FOR ICE CREAM I. EQUIPMENT/MILLWORK SHALL 5E SUPPLIED BY ONE OF THE FOLLOWING NATIONAL SUPPLIERS; 7370 LINCOLN AVE 7 NEST INDUSTRIES �� � True Food ice Ec�ipmert EAVER STREET LINCOLNWOOD, IL 60712 JACKSONVILLE, FL 8220 2001 East Terra Lane (847) 568 -7730 DIRECT (904) 633 -740c1 DIRECT O'Fallon, MO 63366 (547) 514 -8146 CELL (904) 360 -625 FAX 500- 325 -6152 DIRECT (847) 675 -0501 FAY CONTACT: HEATI4ER ARROWSMITH (636) 272 -2408 FAX CONTACT: ERIC CHAPLICK hcrrowsmitheloadkIna.com CONTACT:true rues F�.r echapiick@b elter.carn CE, (18E) 0 0 EMI O' fr ON HI• Q O .0 • 1 6E (19E O 000 O 0 0 0 3E F.E. EQUIPMENT PLAN 0 REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC JUN 3 0 2008 LT Of Tukwila D N DIVISION SCALE: 1/2".7,11-0" F 1 G H NORTH 6" 2' 0' 1' SCALE: 1/2" = I' -0' J 4' RECEIVED CITY of TUKWILA JUN 2 5 2008 PERMIT CENTER K Helix d sigma re=.0 pit AMERICAN INSTITUTE OF ARCHITECTS 4 5 HELIX DESIGN GROUP, INC FLOOR PLAN, EQUIPMENT 7 PLAN& SCHEDULES BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL SEATTLE , WA REVISION DATE 9 DATE 05.0 1.08 JOB NO. 108-043 PERMIT SET 10 A100 DRAWING NO. 2 of 9 0 HELIX DESIGN GROUP, INC.: All rights mod. Ito part aF this daaumank may lie repradurad in any form or by any imam without permission er dola g irnm Helix Design Group J tblm 1 2 3 4 5 6 7 9 A MOSAIC GLASS TILE, T -2 • -+- ELEVATION A B c EQ. EQ. r T�: i Q SIGN TO PE CENTERED ON PYLON SOLID SURFACE TOP CAP, C -2 MOSAIC GLASS TILE, T -2 SOLID SURFACE BASE, C —I SOLID SURFACE GATE, C —I GRAPHIC VINYL SCALE:1 %I'4n SOLID SURFACE TOP CAP C-2 SOLID SURFACE, C-2 SOLID SURFACE BASE, C--1 GRAPHIC BEHIND SAFETY GLAZING SOLID SURFACE TOP CAP C -2 E G H SOLID SURFACE COUNTERTOP, C -2 POWDER COAT METAL J K MOSAIC. GLASS TILE T -2 SOLID SURFACE BASE,C -1 MOSAIC GLASS TILE, T -1 ELEVATION C POIAIDER COAT METAL SCALE: I° =I' —On A B c Q EDGELYTE ECONO LIGHT BOXES FOR PROMO POSTERS ELEVATION B SOLID SURFACE C -2 SCALE : 1n =1' —O° 1 1 1 1 1 1 1 1 - f r N a � GLASS TILE 1 SCHLUTER — SCHIENE 1 1 1 1 1 1 ALUM. TRIM GRAPHIC VINYL 1 1 1 ELEVATION D E GRAPI -TIC VINYL G J SOLID SURFACE C -2 SOLID SURFACE BEYOND, C -2 SOLID SURFACE BASE; C —I GRAPHIC B£I -IIND SAFETY GLAZING SOLID SURFACE TOP CAP C -2 SOLID SURFACE BASE C-1 RECEIVED CITY OF TUKWILA JUN 2 5 2008 • PERMIT CENTER K 2 5 6 7 Helix. esi sign c�rca�.lp AMERICAN INSTITUTE OF ARCHITECTS ELEVATIONS BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL SEATTLE, WA REVISION DATE 9 DATE 05.01.08 JOE NO. 108 -043 PERMIT SET 10 A600 DRAWING NO. 3 of 9 Q HEEDS DESIGN GROUP: ALL RIGHTS RESERVED. No porl al this document moy he rrrcdiced in any form or by any means rlha pmnission el >griting frmr. Hek Design Group 1 4 5 6 7 8 A SOLID SURFACE B COUNTER TOP, C -2 E F G 1 1 1 11 I i I I Il 1 t f _-J SOLID SURFACE TOP CAP, C -2 SOLID SURFACE BASE, C -I 51_9: 5' -1" OPEN ADJUSTABLE SHELVING ELEVATION E DIP CASE DIP CASE STAINLESS STEEL CABINET FACE, TYPICAL. - SCALE:1 "=1' -0" STAINLESS STEEL BACKSPLASI-I, COUNTER TOP * CABINET FACE, TYPICAL. SOLID SURFACE TOP CAP F-- n t ll R4 R3,' 7 7 • N 7 l :'rte, C12- 14,4...4^,2 i_�.I...! "L_ i.. .;.��. �,.>._L _t, �I� 3 Imo' 1:.„-......„1„:„... : r r - -i--; 7 � _ ; Zr r- 1 l -^� ; t- -4:1.; - L w..7.�..... _- 1Y'�- �"- ''w•.;. '--� -wl ..r��7.�.:r "tit _..,,Ii.-1714:,. ::?::,tr-rIT4--i-4:FEH,+2,- -i-4---,-i-,.-i.-. �...L. iii. i!" .!--H :" u r I / / / / E1 MOSAIC GLASS TILE, T -I (3) COMP SINK ELEVATION F SCALF:1 " =1'-O" I' -ce HOT WATER HEATER I I _BIT ICE MAKER TRANSVERSE SECTION SCALE: I/2" .I'^" A B fa' -I" UNDERCOUNTER FREEZER &FRIDGE 1' -3" HAND SINK STORAGE C 1 LONGITUDINAL SECTION SCALE: I /2 " 4-On D E F SECTION VIEW SOLID SURFACE COUNTERTOP CABINET BOX 3/4" PLYWOOD PROVIDE ACCESS FOR MAINTENANCE SAFETY GLAZING N/ TRANSLUCENT GRAPHIC APPLIED LIGHT SOLID SURFACE BASE TREATED WOOD 2"X6" BLOCKING. LIGHT BOX DETAIL H J 61,0 Li [ii3CE NEC JUN 3 0 2008 10fTU,Ia N DIVI ION CABINET BOX SOLID SURFACE PROVIDE ACCESS LIGHT SELF - ADHESIVE TRANSLUCENT GRAPHIC BEHIND SAFETY GLAZING PLAN VIEW SOLID SURFACE SCALE 1-- I/2aI' -O'1 G H J 3/4" PLYWOOD RECEIVED CITY OF TUKWILA ,IUN 2 5 2008 PERMIT CENTER K 2 UFA Helix d si j r,=.0 AMERICAN INSTITUTE OF ARCHITECTS REGISTERED ARCHITECT -RUE McKEAN ATE OF WASHINGTON 4 5 6 ELEVATIONS, SECTIONS, 7 AND DETAILS BEN &. JERRY'S KIOSK 8 SOUTHCENTER MALL SEATTLE, WA REVISION DATE DATE 05.01.08 JOB NO. 108 -043 PERMIT SET 10 A601 DRANNNING NO. 4 of 9 0 HELIX DESIGN GROUP: ALL R1GI-ITS RESERVED. No part di this document may be rhproduced in ony form or by any means without permission in n(ding frern Heir Design Group 1 3 5 7 8 9 A I' -IO 1/2" 1 4" RAL?. @ POEED CORNERS. 11_11 I /2" L' LA NLSS EE T LDP 1/4/ STAINLESS ST STUDS 4 CAP NUTS (3) TGA�STAINLESS * LEFT SIDE SIN, RIGHT SIDE 15 OPPOSITE. SPLASH GUARD SCALE: 1 /4" =1' -0" SOLID SURFACE COUNTER I OP 1ETAL PANEL 'OWDER COAT FINISH aCN 31 2' -3 3/4 "± •Sr 50LII) SURFACE BASE ALL EXPOSED SURFACES EXCEPT THOSE WITHIN PUBLIC VIEW, TO BE METAL 1_IGNT @ EASE TO ILLUMINATE TOE KICK @ DIP CASES TREATED •WOOD 2"Xb" BLOCKING. VERT. MA111L2E P T. TEMEEGR17S SOLID SURFACE COUNTER TOP �COUNTERFTOP D 13/4" 4 R MMETS TO BE EP1�OCNQUI'EATIOS. � RD W/ ARCH. Ii: ELEC. DWGS, 2' -I 3/4" MAY VARY SEE OTHER DETAILS) STAINLESS STEEL COUNTER TOP BACKSPLA5H STAINLESS STEEL COUNTERTOP PROFILE. MENU NALL STAINLESS STEEL COUNTER TOP 4 BACKSPLASH 3/4" PLYWOOD 3/4" MELAMINE ati r.]-1,1VVYY iArS111})))1 71.3311 -1 ]» ] ?1111M e5 PLYWOOD ARID MELAMINE SACS EL STAINLESS COUNTT (SHOWN IN PLACE) REAR• CUJNfER MODULES RI I5 "1.1 NAND SINK UNIT R2 DOUBLE DOOR Wf INT, ADJUSTABLE SHELF UNIT COUNTER TOP @ BACKBAR E METAL PANEL PONDER COAT : FINISH METAL PANEL POWDER COAT FINISH • cr 'N SCALE: 1/4° = I'--O° 7 1/2" 5 3/4" 1' 4" 1 3/4" 5•: SOLID SURFACE BASE 3r 4 3/4" ,` SECTION DIP CASE SCALE: 1/4° A C LIGHT @ BASE TO ILLUMINATE TOE KICK @ DIP CASES TREATED WOOD 2 "X " BLOCKING. 3/4" 3" 2' -G 1/4" SECTION @ CONE STORAGE S. 5HE P TIRE RE 0/ AR RUBBER BASE SCALE: I/4" =I'-O" 1 D I E F SOLID SURFACE SUBSTRATE COUNTERTOP SURFACE MATERIAL VARIES, SEE ELEVATIONS FOR MATERIAL CALL OUT SOLID SURFACE BASE 6 3/4" sra KS`J a� r SSS SY:), - � 2 4--11 I I II I I 11 G ALL EXPOSED SURFACES EXCEPT NITNIN KIOSK TO BE STAINLESS STEEL SOLID SURFACE BASE TYPICAL WALL DETAIL SCALE: I- I /2" =1' -O" F G H TRIM SOMMER #7412 PIVOT HINGE 5 1 /2" GATE DETAIL SCALE: I4/2" =1' -O" 1 J fWS-cz-to TRIM 1/4 "� 3'41 PIVOT HING � K SOLID SURFACE SUBSTRATE ( FULL HEIGHT ) @ HINGE ATTACHMENT. B0111ER #7412 PIVOT • HINGE RECEIVED CITY OF TUKW1LA JUN 2 5 2008 PERMIT CENTER J K 1 2 Helix d si jr-, raup AMERICAN INSTITU'T'E OF ARCHITECTS 4 5 6 ELEVATIONS, SECTIONS, 7 AND DETAILS BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL SEATTLE .. WA REVISION DATE 9 DATE 05.0 1.08 JOB NO, 108-04.3 PERMIT SET 10 A602 DRAWING NO.- 5 of 9 D HELIX DESIGN GROUP; ALL RIGHTS RESERVED. Iin port of this document may be reproduced in any form or by ony moons without permission in writing from Hefu Design Group J A 1 3 4 5 6 8 9 10 B C 1 D E G H J K SPECIFICATIONS 15010 -- GENERAL 1. CODE COMPLIANCE: ALL WORK SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES. 2. DRAWINGS: DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF THE CONSTRUCTION, AND THEREFORE DO NOT SHOW ALL NECESSARY OFFSETS, FITTINGS, AND ALTERATIONS TO EXISTING ITEMS, AND ACCESSORIES WHICH ARE REQUIRED TO FORM COMPLETE AND OPERABLE SYSTEMS. 3. FIELD VERIFICATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING FIELD CONDITIONS, REVIEWING EXISTING RECORD DRAWINGS, AND VERIFYING ALL MEASUREMENTS AND RELATIONSHIPS INDICATED ON THE DRAWINGS BEFORE SUBMITTING BIDS AND AGAIN BEFORE PROCEEDING WITH THE WORK_ 4. PERMITS AND FEES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL .PERMITS, LICENSES, FEES AND INSPECTIONS AS REQUIRED BY THE GOVERNING CODES AND AS SPECIFIED HEREIN. (UNO). 5. SUBMITTALS: CONTRACTOR SHALL SUBMIT PRODUCT DATA INFORMATION FOR ALL PRODUCTS PROPOSED TO BE USED ON THIS PROJECT FOR OWNER REVIEW. PRODUCTS SHALL NOT BE USED UNTIL APPROVED BY THE OWNER OR HIS REPRESENTATIVE. SUBMIT 3 COPIES PLUS ANY ADDITIONAL QUANTITIES THE CONTRACTOR NEEDS (3 COPIES WILL BE RETAINED BY THE OWNER). 6. RECORD DRAWINGS: THE CONTRACTOR SHALL MAINTAIN A SET OF CONTRACT PLANS AT THE PROJECT SITE UPON WHICH ALL CHANGES FROM THE AS -BID PLANS ARE NOTED. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DELIVER TO THE OWNER ONE COMPLETE SET OF THESE RECORD DRAWINGS. 7, PROTECTION: CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL MATERIAL, EQUIPMENT AND APPARATUS PROVIDED UNDER THIS SECTION FROM DAMAGE, WATER, CORROSION, FREEZING AND DUST, BOTH IN STORAGE AND WHEN INSTALLED, UNTIL FINAL PROJECT ACCEPTANCE. 8. COORDINATION: THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACTIVITIES WITH THE OWNER AND COOPERATE FULLY SO AS TO MINIMIZE CONFLICTS AND TO ALLOW FULL OWNER USAGE '(UNLESS INDICATED OTHERWISE) OF ALL AREAS DURING CONSTRUCTION. 9. CUTTING AND PATCHING: SHALL BE DONE BY SKILLED LABOR EXPERIENCED IN PROVIDING OPENINGS AND PATCHING OF THE MATERIALS INVOLVED. AREAS SHALL BE PATCHED AND RESTORED TO A FINISHED CONDITION, EQUAL TO ADJACENT FINAL FINISHED AREAS THAT HAVE NOT BEEN CUT, 10. PAINTING: SHALL BE PROVIDED WHERE INDICATED, BY SKILLED PAINTERS IN CONFORMANCE WITH STANDARD PROFESSIONAL PRACTICE INCLUDING CLEANING AND PRIMING OF MATERIALS TO BE PAINTED. COLORS SHALL BE SELECTED BY THE OWNER 11. FINAL INSPECTION: PRIOR TO ACCEPTANCE OF THE WORK, THE CONTRACTOR SHALL PUT ALL SYSTEMS INTO OPERATION FOR A • PERIOD OF NOT LESS THAN 5 WORKING DAYS S0 THAT THEY MAY BE INSPECTED BY THE OWNER. 12. WARRANTY: ALL WORK AND EQUIPMENT SHALL BE WARRANTED TO BE FREE FROM DEFECTS AND CAPABLE OF PROVIDING SATISFACTORY OPERATION FOR A PERIOD OF ONE YEAR. SEE GENERAL CONDITION FOR MORE INFORMATION. 13. NEW MATERIALS: ALL ITEMS ARE NEW UNLESS SPECIFICALLY NOTED AS EXISTING. 14. COMPLETE SYSTEMS: NOT ALL NECESSARY MATERIALS TO PERFORM THE WORK REQUIRED ARE SPECIFIED OR SHOWN. CONTRACTOR SHALL PROVIDE ALL ITEMS NEEDED TO HAVE COMPLETED PROPERLY OPERATING SYSTEMS; ITEMS PROVIDED SHALL BE OF COMMERCIAL /INSTITUTIONAL QUALITY, CONSISTENT WITH THE QUALITY OF RELATED ITEMS PROVIDED ON THE PROJECT OR CURRENTLY BEING USED IN THE BUILDING. 15. IDENTIFICATION: A. PIPING: SHALL BE MARKED ON 20 FOOT CENTERS WITH SELF - STICKING COLORED MARKERS, LEI ILRED TO IDENTIFY THE PIPE CONTENTS, AND BANDED AT EACH END WITH ARROW TAPE INDICATING THE DIRECTION OF FLOW. MARKERS SHALL BE SIMILAR AND EQUAL TO BRADY "SYSTEM 1." LETTERING AND COLORS SHALL COMPLY WITH ANSI A13.1. EXCEPT THAT WHERE EXPOSED TO VIEW TO GENERAL MALL PATRONS, NO LABELING IS REQ'D_ B. VALVES: SHALL ALL BE MARKED WITH IDENTIFICATION TAGS MADE OF BRASS OR ALUMINUM, STAMPED WITH VALVE NUMBER AND ABBREVIATION OF SYSTEM SERVED. COORDINATE WITH OWNER FOR NUMBERING AND C.D. TO BE USED. LABEL AS- BUILTS W/ VALVE ID NUMBERS ASSIGNED. 16. TESTING: ALL PIPING AND SYSTEMS SHALL BE PRESSURE TESTED PER CODE REQUIREMENTS AND TO AT LEAST 1.5 TIMES THE SYSTEMS ALLOWED OPERATING PRESSURE AND IN ACCORDANCE WITH CODE AND THE OWNER'S STANDARDS. 17. CONTRACTOR LAY -OUT: THE CONTRACTOR IS REQUIRED TO DO FURTHER LAYOUT TO FINALIZE THE DESIGN SHOWN ON THE PROJECT DRAWINGS. SUCH WORK INCLUDES FIELD INVESTIGATION OF ALL EXISTING CONDITIONS, LAYOUT SKETCHES TO VERIFY RISES AND DROPS IN PIPING AND COORDINATION WITH EXISTING ITEMS. 18. INSTRUCTION/0 & M MANUALS: DURING THE FINAL INSPECTION PERIOD, THE CONTRACTOR SHALL PROVIDE INSTRUCTIONS AND DEMONSTRATIONS FOR THE OWNER'S REPRESENTATIVES ON THE OPERATION AND MAINTENANCE OF ALL EQUIPMENT, AND PROVIDE 3 SETS OF O &M MANUALS. 0 & M MANUALS SHALL INCLUDE CONTACT INFORMATION FOR ALL CONTRACTORS AND SOURCES FOR ALL PRODUCTS, AND FACTORY 0 & M MANUALS FOR ALL EQUIPMENT. 19. ALL ITEMS DAMAGED IN THE COURSE OF PERFORMING THE WORK OF THIS PROJECT SHALL BE REPAIRED TO PRE - CONSTRUCTION CONDITIONS OR BETTER. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING EQUIPMENT, WIRING, DUCTS AND OTHER ITEMS IN AREAS WHERE WORK IS BEING PERFORMED. THE CONTRACTOR SHALL TAKE NECESSARY STEPS TO PROTECT SUCH ITEMS FROM DUST, DEBRIS AND WATER DAMAGE. 20, PROVIDE BARRICADES & SIMILAR PROTECTIONS TO KEEP NON - CONSTRUCTION PERSONNEL CLEAR OF CONSTRUCTION AREAS. 21. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ADDENDAS AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. ELECTRICAL, ARCHITECTURAL, AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS ARE A PART OF THE CONTRACT DOCUMENTS. 22. UNSIZED PLUMBING PIPING SHALL MATCH THE SIZE OF THE LARGEST ADJACENT CONNECTING PIPE SIZE SHOWN, WHERE THE ADJACENT PIPE I5 NOT SHOWN (OR NOT CLEAR), THE PIPE SIZE SHALL BE BASED ON THE GPM FLOWING IN THE PIPE (USE TOTAL OF COILS SERVED FOR HYDRONIC SYSTEM, USE FIXTURE UNITS AND CORRESPONDING GPM PER THE UPC FOR DOMESTIC WATER SYSTEMS, USE WASTE FIXTURE UNITS & UPC TABLES FOR WASTE /VENT SYSTEM), AND A VELOCITY NO GREATER THAN 4 FEET PER SECOND. USE UPC CURVES FOR GPM /VELOCITY FOR APPROPRIATE PIPING MATERIAL INVOLVED. 15060 -- PIPE AND PIPE FITTINGS 1. DOMESTIC WATER PIPE AND FITTINGS: TYPE L COPPER, PER ASTM B88, SOLDER FITTINGS PER ANSI B16.22/B16.24. 2. WASTE & VENT PIPING: SERVICE WEIGHT NO-HUB CAST IRON PER CISPI 301 AND ASTM A 888, FOR USE W/ NO-HUB COUPLINGS. COUPLINGS SHALL COMPLY W/ CISPI 310 OR ASTM C 1277. OR, SCHEDULE 40 GALVANIZED' STEEL PIPE PER ASTM A 53, WITH CAST IRON DRAINAGE FITTINGS PER ASME B 16.12 & B 15.4. 3. TRAP PRIMER PIPING: TYPE K SOFT COPPER WITH NO JOINTS FROM TRAP PRIMER TO DRAIN. 4. INSTALLATION: A. INSTALL PIPING CONCEALED UNLESS SPECIFICALLY NOTED OTHERWISE. COORDINATE WITH OTHER TRADES AND ALL EXISTING CONDITIONS. INSTALL TO ALLOW MAXIMUM ACCESS TO COMPONENTS INSTALLED IN PIPING SYSTEM. B. FOLLOW ESTABLISHED PROFESSIONAL PRACTICES FOR JOINING OF PIPING AND SO AS TO SUIT THE SYSTEM PRESSURES AND TEMPERATURES INVOLVED. 15080 - PIPING SPECIALTIES, 1. THERMOMETERS: DIAL BIMETAL TYPE, 3 -INCH DIAL SIZE, BRASS OR STAINLESS STEEL CONSTRUCTION, WHITE FACE WITH BLACK NUMERALS, AND MARKINGS IN DEGREES F. PROVIDE SOCKETS WITH EXTENSION NECKS WHERE . INSTALLED ON INSULATED PIPING. THERMOMETER TEMPERATURE RANGE FOR DOMESTIC HOT WATER: 0 TO 200 DEGREES F. 2. WATER STRAINERS: "Y" TYPE, SAME SIZE AS THE PIPE IN WHICH THEY ARE INSTALLED, WITH BRONZE RATED FOR 125 PSI WORKING PRESSURE, AND WITH REMOVABLE PLUG AND SEDIMENT SCREEN. BASKET SCREEN SHALL BE STAINLESS STEEL OR MONEL, 20 MESH, WITH A NET FREE AREA OF AT LEAST 3 TIMES THAT OF THE ENTERING PIPE. PROVIDE WITH SLOWDOWN VALVE. 3. UNIONS: RATED AT MINIMUM 125 PSIG AT 200 DEGREES F; PROVIDE DIELECTRIC UNIONS WHERE DISSIMILAR METALS JOIN. PROVIDE UNIONS AT CONNECTIONS TO ALL EQUIPMENT. 4. ESCUTCHEONS: SHALL BE CHROME PLATED, PROVIDE FOR ALL EXPOSED PIPING AT WALL, FLOOR, CEILING AND SIMILAR PENETRATIONS. 5. CLEANOUTS: A. FLOOR TYPES: J.R. SMITH FIG_ 4025, SATIN BRONZE TOP. B. WALL TYPE: J:R. SMITH FIG. 4422, DUCO CAST IRON FERRULE, BRONZE PLUG, STAINLESS STEEL COVER. 6. TRAP PRIMER VALVE: PRECISION PLUMBING PRODUCTS MODEL P -1 AND P -2, WITH ADJUSTABLE OPERATION. 7. DOMESTIC WATER EXPANSION TANK: DIAPHRAM TYPE, WELDED STEEL WITH HEAVY DUTY BUTYL DIAPHRAM AND RIGID POLYPROPYLENE LINER, CHARGING VALVE AND TANK FITTINGS. 8. ACCESS DOORS: STAINLESS STEEL CONSTRUCTION, MINIMUM 16 GUAGE, W/ FULL PIANO TYPE HINGE, & KEYED LOCKING MECHANISM. 15090 -- HANGERS, SUPPORTS. SLEEVES AND SEALS 1. PIPE HANGERS AND SUPPORTS: A. GENERAL: SHALL CONFORM TO MSS SP ---58 AND MSS SP-69 AND SHALL BE COPPER PLATED WHERE IN CONTACT WITH COPPER PIPE OR BE PROVIDED WITH FACTORY MADE SOLATORS TO PREVENT CONTACT OF DISSIMILAR MATERIALS. UNISTRUT SHALL NOT BE USED TO SUPPORT HORIZONTAL PIPING, EXCEPT WHERE RACKED AGAINST A WALL AND NO OTHER SUPPORT MEANS IS REASONABLE. ALL STEEL HANGERS SHALL BE CADMIUM PLATED, OR BE GALVANIZED STEEL, B. HANGERS: SHALL PERMIT ADEQUATE ADJUSTMENT AFTER ERECTION WHILE STILL SUPPORTING THE LOAD. PIPE GUIDES AND ANCHORS SHALL BE INSTALLED TO KEEP PIPES IN ACCURATE ALIGNMENT, TO DIRECT EXPANSION MOVEMENT, AND TO PREVENT BUCKLING, SWAYING, AND UNDUE STRAIN. C. SPACING: SHALL BE SPACED AS SPECIFIED IN MSS SP -69 AND BY CODE, AND A SUPPORT SHALL .BE INSTALLED NOT OVER 1' FROM THE PIPE FITTING JOINT AT EACH CHANGE IN DIRECTION OF THE PIPING (EOR PIPING 2" AND LARGER). . D. INSULATION: SHALL BE CONTINUOUS THROUGH ALL SUPPORTS, PROVIDE INSULATION SUPPORTS PER SECTION 15250. 2, PIPE SLEEVES AND SEALS: SLEEVES SHALL BE FABRICATED OF 20 GAUGE SHEETMETAL AND SHALL ALLOW 1/2" SPACE AROUND INNER PIPE AND SHALL EXTEND AT LEAST 1" BEYOND PENETRATED ELEMENT SURFACES. PROVIDE SLEEVES AT ALL WALL, FLOOR, AND CEILING PENETRATIONS (EXCEPT WHERE COMPLETELY SOLID INTERIOR ELEMENTS SUCH AS CONCRETE SLABS ARE PENETRATED). SEAL BETWEEN SLEEVE AND PIPE WITH UL APPROVED FIRE SEALANT; (EXCEPT WHERE FIRE /SMOKE SEPERATION IS NOT REQUIRED PROVIDE SILICON TYPE SEAL OR ROCK WOOL.). SEAL BETWEEN SLEEVE AND ELEMENT PENETRATED WITH SAME MATERIAL ELEMENT IS CONSTRUCTED OF (LE., CONCRETE, PLASTER, ETC.). ALL SEALING SHALL BE PROVIDED SO AS TO MAINTAIN THE FIRE & SMOKE RATING OF THE ELEMENT BEING PENETRATED. 15100 - VALVES 1. ACCEPTABLE MANUFACTURERS: NIBCO, RED - WHITE, MILWAUKEE, APOLLO, HAMMOND, WATTS. 2. COLD WATER AND HOT WATER SERVICE 125 PSI -SWP BRONZE BODY BALL VALVES, FULL PORT, NIBCO S580, T580, OR EQUAL. 3. CHECK VALVES: 125 PSI ---SWP BRONZE HORIZONTAL SWING TYPE. NIBCO S -413, T-413, OR EQUAL. 4. DRAIN VALVES: NIBCO S- 585- 70 -HC, T- 585- 70 -HC, OR EQUAL. 5. BACKFLOW PREVENTORS: WASHINGTON STATE APPROVED, TYPE AS INDICATED, INSTALL WITH UNION CONNECTIONS, UPSTREAM STRAINER AND TO BE ACCESSIBLE. 6. INSTALLATION: INSTALL VALVES WITH STEM VERTICAL AND HANDLE UP WHEREVER POSSIBLE; IN NO CASE BELOW HORIZONTAL. INSTALL IN LOCATION FOR EASE OF ACCESS. INSTALL ALL VALVES IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS; RELIEF VALVES SHALL HAVE FULL SIZE INLET ANT OUTLET CONNECTIONS. 15250 - INSULATION 1. PIPING INSULATION: RIGID FIBERGLASS INSULATION, THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.24 BTU -- INCH /HR- SQ.FT.- DEGREES F. AT 75 DEGREES F. WITH JACKET CONSISTING OF HIGH DENSITY WHITE KRAFT BONDED TO ALUMINUM FOIL, WITH PRESSURE SENSITIVE CLOSURE SYSTEM, INTEGRAL VAPOR BARRIER WITH 0.02 PERM RATING. INSULATE ALL DAMAGED (IN THE COURSE OF THIS PROJECT) EXISTING PIPING INSULATION. PROVIDE INSULATION ON ALL HW, CW, HWC PIPING AS REQUIRED BY THE ENERGY CODE, BUT NO LESS THAN 1/2" INCH THICK. 2. HANGER INSERTS: EXPANDED PERLITE OR CALCIUM SILICATE INSULATION; WITH NO MORE THAN 5% DEFORMATION AT 100 PSI; AND MAXIMUM CONDUCTIVITY OF 0.32 BTU- 1N /HR- SQ.FT.- DEGREE F: WITH MINIMUM 18 GAUGE GALVANIZED STEEL SHIELDS. MICHIGAN HANGAR CD. NOS. 124, 1031, 4031; OR EQUAL. PROVIDE 360' TYPE INSERT WHERE PIPE IS CLAMPED FOR SUPPORT. 3. PIPING INSULATION INSTALLATION: A. PROVIDE INSULATION ON THE SURFACES OF ALL ENERGY CONVEYING, ENERGY CONSUMING, OR ENERGY STORAGE DEVICES (I.E. PIPES, EQUIPMENT, VALVES, FITTINGS, ACCESSORIES, ETC.) INSTALLED AS PART OF THIS PROJECT EXCEPT WHERE SPECIFICALLY EXCLUDED. PROVIDE INSULATION ON ALL ITEMS WHERE EXISTING 'ASBESTOS INSULATION WAS REMOVED OR EXISTING INSULATION WAS DAMAGED. B. PROVIDE INSULATION CONTINUOUS THROUGH ALL SUPPORTS USING HANGER INSERTS. 15450 --- PLUMBING FIXTURES AND WATER HEATERS, 1. GENERAL: PROVIDE ALL STOPS, TRAPS, ESCUTCHEONS, CONNECTIONS, CARRIERS ETC., FOR ALL FIXTURES AS NECESSARY TO COMPLETE THE INSTALLATION OF EACH FIXTURE, WHETHER SUCH ITEMS ARE LISTED OR NOT. STOPS SHALL BE QUARTER TURN BALL TYPE, BRASSCRAFT. 2. THE WATER HEATER(S) SHALL. HAVE CAPACITY AS SCHEDULED, AND BE FOR USE WITH ELECTRICITY OF VOLT /PH INDICATED, AND BE LISTED BY UNDERWRITER'S LABORATORIES. HEATER(S) SHALL HAVE 150 PSI WORKING PRESSURE AND BE EQUIPPED WITH EXTRUDED HIGH DENSITY ANODE ROD. ALL INTERNAL SURFACES OF THE HEATER(S) EXPOSED TO WATER SHALL BE GLASS -LINED WITH AN ALKALINE BOROSILICATE COMPOSITION THAT HAS BEEN FUSED TO STEEL BY FIRING AT A' TEMPERATURE RANGE OF 1600 °F. ELECTRIC HEATING ELEMENTS SHALL BE MEDIUM WATT DENSITY WITH ZINC PLATED COPPER SHEATH. EACH ELEMENT SHALL BE CONTROLLED BY AN INDIVIDUALLY MOUNTED THERMOSTAT AND HIGH TEMPERATURE CUTOFF SWITCH. THE OUTER JACKET SHALL BE OF BAKED ENAMEL FINISH AND SHALL BE PROVIDED WITH FULL S1ZE CONTROL COMPARTMENT FOR PERFORMANCE OF SERVICE AND MAINTENANCE THROUGH HINGED FRONT PANELS AND SHALL ENCLOSE THE TANK WITH FOAM INSULATION. TANK SHALL HAVE DRAIN VALVE, LOCATED IN THE FRONT FOR EASE OF SERVICING. HEATER TANK SHALL HAVE A THREE YEAR WARRANTY. 3. FLOOR DRAINS: GALVANIZED CAST IRON BODY, NICKEL BRONZE ADJUSTABLE STRAINER HEAD, ROUND NICKEL BRONZE GRATE, REVERSIBLE FLASHING COLLAR, AND TRAP PRIMER CONNECTION. PROVIDE WITH 4" DIAMETER FUNNEL WHERE USED TO SERVE RELIEVE VALVES OR INDIRECT_ WASTES. 4. FLOOR RECEPTOR: CAST IRON FLANGED RECEPTOR WITH ACID RESISTANT COATED INTERIOR, NICKEL BRONZE RIM, DOME BOTTOM STRAINER, NICKEL BRONZE 1/2 GRATE, AND TRAP PRIMER CONNECTION. INSTALL FLUSH WITH FINISHED FLOOR, 5. FUNNEL DRAINS: CAST IRON FUNNEL DRAIN W/ P -TRAP, WITH, ACID RESISTANT COATING INSIDE & OUT. 6. GREASE INTERCEPTOR: MINIMUM CAPACITY AS SCHEDULED, AND DIMENSIONS TO SUIT SPACE AVAILABLE. STEEL CONSTRUCTION W/ ACID RESISTANT COATING 'INSIDE & OUT, FOR ABOVE FLOOR MOUNTING PROVIDE W/ SEMI - AUTOMATIC DRAW OFF VALVES, & FLOW CONTROL FITTING. PROVIDE EXTRA FLOW CONTROL FITTING TO SERVE INDIRECT DRAIN PIPING. PLUMBING FIXTURE SCHEDULE MECHANICAL LEGEND SYMBOL DESCRIPTION ABBR.. DESCRIPTION HW WASTE OR SOIL (W) AFF ARCH AUTO AAV BLDG. CAP • CO CONN CONT CFM • CW CWV DEG F, F. DIA, 0 D N DWG ELEC ENT EWT EXH (E) EXIST F FCO FD FLEX FL FR GA GAL GALV. HW IN KW LBS LVG LWT MFR MAX MECH MIN . NO NC NO. NTS OPER PD PH REF REQ'D RM TEMP TYP UG UNO V W/ W ABOVE FINISHED. FLOOR ARCHITECTURAL AUTOMATIC AUTOMATIC AIR VENT BUILDING CAPACITY CLEANOUT CONNECTION, CONNECT CONTINUE, CONTINUATION CUBIC. FEET PER MINUTE COLD WATER COMBINATION WASTE VENT DEGREE FAHRENHEIT DIAMETER DUCTILE IRON DOWN DRAWING ELECTRICAL, ELECTRIC ENTERING ENTERING WATER TEMPERATURE EXHAUST EXISTING EXISTING FIRE FLOOR CLEAN OUT FLOOR DRAIN FLEXIBLE FLOOR FLOOR RECEPTOR GAUGE GALLON GALVANIZED HOT WATER INCH KILOWATT POUNDS LEAVING LEAVING WATER TEMPERATURE MANUFACTURER MAXIMUM MECHANICAL MINIMUM NORMALLY OPEN NORMALLY CLOSED NUMBER NOT TO SCALE OPERATING PRESSURE DROP PHASE REFERENCE REQUIRED ROOM TEMPERATURE TYPICAL UNDERGROUND UNLESS NOTED OTHERWISE VENT WITH WASTE SIZE AS SHOWN ON PLAN - VENT () (V) FUNNEL DRAIN COLD WATER (CW) 2" - HOT WATER (HW) JR SMITH FIG, 3821T, WITH 6 "0 FUNNEL, ALUMINUM DOME STRAINER GI -1 HOT WATER CIRCULATING (HWC) 3" 3" PIPE UP O �--C PIPE DOWN ISOLATION VALVE (BALL TYPE) Q CHECK VALVE --T- -4--- --- UNION CONCENTRIC REDUCER ---P THERMOMETER RELIEF VALVE OR SAFETY VALVE 1• ----- 0 FLOOR CLEANOUT (FCO) POINT OF CONNECTION TO EXISTING PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION * w * v CW HW REMARKS FD-1, FLOOR DRAIN W/ FUNNEL SIZE AS SHOWN ON PLAN JR SMITH FIG. 3510, WITH 6" DIA TOP STRAINER, FUNNEL, & TRAP PRIMER CONN. FUN -1 FUNNEL DRAIN 3+° 2" - - JR SMITH FIG, 3821T, WITH 6 "0 FUNNEL, ALUMINUM DOME STRAINER GI -1 GREASE INTERCEPTOR 3" 3" - _ JR SMITH. FIG. 8015GT, 15 .GPM FLOW RATE, 30 LB GREASE CAPACITY, W/ OUTLET VALVE & GREASE DRAW OFF VALVE. MAX DIMENSIONS: 26 "L x 17 "W x. 15-1/2"H. W/ RELIEF VALVE, DRAIN VALVE • * COMBINATION WASTE VENT (CWV) SYSTEM USED, NOT ALL FIXTURES HAVE VENTS CONNECTED TO FIXTURE PIPING. WATER HEATER SCHEDULE . SYMBOL SPECIFIED MFR. AND SERIES NO. TYPE AREA . SERVED INPUT STORAGE (GAL) DOMESTIC HW ELECTRICAL REMARKS • • .GPH EWT LWT FLA VOLTS /PH (9E) SMITH DEL 10 ELECTRIC TANK KIOSK Hey 6 KW 10 31 40 120 28.8 208/1 W/ RELIEF VALVE, DRAIN VALVE CODE COMPLIANCE E NFPA 70 -NEC JUN 3 0 1008 BUILDIhG D ON RECEIVED c1TY OF TUKWILA JUN 2 5 ZOOS PERMIT CENTER � A B C D 1 E F G H J K 2 3 desigr1 group AMERICAN INSTITUTE OF ARCHITECTS 1 EXPIRES el-14-06 HELIX DESIGN GROUP, INC HULTZ C ROSS consulting engineers, Inc. 2407 North 31st West Phone: (253) 383,3257 4 general @hultzbhucross.com 5 Tacoma, WA 28407 Far (253) 383 -3283 Job Number. 08.091 MECHANICAL 7 LEGEND, NOTES & SCHEDULES BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL TUKWILLA, WA REVISION DATE 9 DATE JOB NO, 05,02.08 108 -043 PERMIT SET 10 M 1.0 DRAWING NO. 6of9 HELIX DESIGN GROUP, INC.: an riepts rwernd. J A 1 2 3 4 5 6 7 8 10 FUN -1 FLOW CONTROL FITTING #2 A B PIPE FULL SIZE TO FLOOR DRAIN R-10 RIGID INSULATION 2 "V 1" DRAIN PIPED TO FLOOR DRAIN CABINET, SEE ARCH DRAWINGS „ ` , W WATER HEATER rlrr9rrJJrrrrrrr rrrrrr irrrri. 1„ CW EXPANSION TANK THERM- X -TROL ST -5 CHARGE TO BLDG. STATIC PRESSURE LEVEL, LOCATE REMOTE FROM CABINET HOSE END THREADED DRAIN VALVE W/ CAP 6" HIGH SQUARE DRAIN PAN, MIN 20 GA. GALV., WELDED STEEL CONSTRUCTION, WATERTIGHT WATER HEATER DETAIL (1\ NTS M2.0_) t r ^ —� – AS SHOWN) CW LINE TO FREQUENTLY USED FIXTURE (OR LINE AS INDICATED ON PLAN) TO FIXTURE (OR _.___ _ - ACCESS DOOR (WHERE CONCEALED IN WALL) 1/2" (TYP), TYPE K SOFT COPPER, W/ NO JOINTS TRAP PRIMER VALVE ADJUSTABLE TYPE PRIMER MANIFOLDS) (WHERE SERVING MORE THAN ONE FLOOR DRAIN) i FINISHED FLOOR TO FLOOR DRAIN TRAP (TYP.) NOTE: LOCATE TO BE ACCESSIBLE. LOCATION ON PLANS IS PRELIMINARY ONLY, CONTRACTOR TO CONFIRM. TRAP PRIMER DETAIL (2: n NTS SIZE TO MATCH FLOW CONTROL FITTING CONN. FLOW CONTROL FITTING #1 3 "W WASTE FROM 3- COMPARTMENT SINK 2"V 1 CO-1 �� LINE SHUT -OFF VALVE, FURNISHED W/ GI -1 4" FC0 4" (cWV) 3 "V . . 3"V 2" FD -1 .,r REDUCER (TYP) 3 "(CWV) 2" FD -1 4 "(CWV) 4 "(CWV) 3"V, CONN TO (E) 3 "V & ON TO (E) VTR 2 „V S 3 "(CWV) CO (E) 4 "W WASTE VENT RISER DIAGRAM NTS B 2 "W D FLOOR PENETRATION, SEAL & PROVIDE ESCUTCHEON (TYP) D E (E) 3"V 02"V, 3 /4 "CW, 3 /4 "HW 3 "V, 1 "CW, 1 /2 "HW F 1/2"CW DN THRU FLOOR 011111Pli 2"V' 1 "CW, 1 /2'HW G 1 2 "V _r.......�. _. I r EXPANSION TANK FUN -1 SINK WASTE (TYP) 2" FD -1 1/2" TO 11E • 2" FD -1 OUTLINE OF KIOSK ABOVE Fp f 7 J 2 "W DN THRU FLOOR ;.A l- -• -- ,- ABOVE FLOOR PLUMBING PLAN SCALE: 1 /2°- 1' -OiI E 4 "W UP IL-- 4 "W Q L 3 "W (CWV) L - - - -- PROVIDE FULL SIZE TRAP (SAME SIZE AS BRANCH LINE) W/ REDUCER TO FIXTURE CONN SIZE (TYP) 3 "W (CWV) .s- 1 /2 "CW - 1 /2»CW UP 4 "W (CWV) J 2 "W UP (-E3 FP- OI,DIN M2,0 2 "W� NOTE: PIPING RUNS IN CEILING SPACE BELOW KIOSK (UNO). UNDER FLOOR PLUMBING PLAN CO 1 "CW UP THRU FLOOR PROVIDE W/ ISOLATION VALVE ABOVE FLOOR tt.„01: 1 "CWUP SCALE: I/2° =1' -0" FP -OLDN F 1 G M2.O H J GENERAL NOTES 1. SEE ARCHITECTURAL PLANS, KIOSK EQUIPMENT SCHEDULE, & SPECIFICATIONS FOR REQ'D PLUMBING CONNECTIONS TO ITEMS IN THE KIOSK. ALL ITEMS REQUIRING PLUMBING CONNECTIONS SHALL BE COMPLETELY CONNECTED BY THE PLUMBING CONTRACTOR. THIS INCLUDES PROVIDING ALL HW /CW /WASTE /VENT /MISC DRAIN PIPING, TRAPS, FITTINGS, STOPS (IN ALL WATER PIPING TO ITEMS), VALVES, SOLENOID VALVES, GASKETS, UNIONS, VACUUM BREAKERS, BACKFLOW PREVENTORS, ESCUTCHEONS, WATER HAMMER ARRESTERS, ACCESS DOORS, PIPE SHROUDS, & ALL ACCESSORIES. • 2. FOR PIPING SIZES TO INDIVIDUAL PLUMBING ITEMS SEE ARCHITECTURAL PLANS, KIOSK EQUIPMENT SCHEDULE, PLUMBING FIXTURE SCHEDULE & SPECIFICATIONS. 3. THE PLUMBING CONTRACTOR SHALL INSTALL ALL FITTINGS, VALVES & CONTROLS FURNISHED WITH THE FOOD SERVICE EQUIPMENT AS LOOSE ITEMS, AND SHALL PROVIDE ALL INTERCONNECTION PIPING REQUIRED TO COMPLETE EACH EQUIPMENT HOOK -UP FOR PROPER OPERATION & CONNECTIONS TO PLUMBING SERVICES. DESIGNATES KIOSK EQUIPMENT ITEMS. SEE ARCHITECTURAL DRAWINGS. 5. VERIFY LOCATIONS OF ALL ITEMS W/ OTHER TRADES BEFORE BEGINNING WORK. 6. SUBMIT SHOP DRAWINGS WITH DIMENSIONED LOCATION OF ALL FLOOR DRAINS & FLOOR RECEPTORS BEFORE INSTALLING. 7. VERIFY ADEQUATE SPACE FOR WATER HEATER BEFORE ORDERING. 8. VERIFY CONNECTION LOCATIONS & REQUIREMENTS OF ALL ITEMS PRIOR TO BIDDING. PLANS ARE SCHEMATIC ONLY & DO NOT SHOW ALL NECESSARY OFFSETS, PIPE LENGTHS, & ACCESSORIES FOR FtJLL CONNECTIONS. 9. LOCATION OF EXISTING ITEMS IS BASED ON INFORMATION PROVIDED BY OTHERS, AND HAS NOT BEEN. FIELD VERIFIED. KEYED NOTES CONNECT TO EXISTING. FIELD VERIFY SIZE & LOCATION. ASSUME LOCATION IS 20 FEET AWAY FROM LOCATION NOTED REQUIRING 2 ADDED FITTINGS. (UNLESS FIELD VERIFIED PRIOR TO BIDDING). 0 1/2" DOUBLE CHECK BACKFLOW PREVENTOR. • 1/2" TRAP PRIMER LINE. 4 PROVIDE TRAP PRIMER TO SERVE ADJACENT DRAINS. SEE DETAIL 2 /M2.0 0 RUN ALL PIPING IN WALL, SOME PIPING SHOWN OFFSET FOR CLARITY (TYP). 06 PROVIDE INDIRECT WASTE TO ADJACENT FR OR FD. REFERENCE ARCHITECTURAL DRAWINGS FOR SIZING INFORMATION. 0 PROVIDE CLEANOUT IN VENT PIPING. 0 CABINET HOUSING WATER HEATER; CUT OPENINGS IN CABINET TO ACCOMMODATE ALL PIPING AND ALLOW DRAINAGE TO FD -1. E INSTALL GREASE INTERCEPTOR ABOVE FLOOR & BELOW 3- COMPARTMENT SINK. VERIFY & COORDINATE SIZE & LOCATION WITH 3- COMPARTMENT SINK & SINK LEGS. CUSTOM FABRICATED SINK LEG LOCATIONS MAY BE REQUIRED, REVIEWED FOR CODE COMPLIANCE NFPA7D -NEC JUN 30 2008 City Of Tukwila BUILDIN DIVI ION J RECEIVED CITY OF TUKWILA JUN 2 5 2008 PERMIT CENTER K 3 design group AMERICAN INSTITUTE OF ARCHITECTS E PlRES 8 -14-00 HELIX DESIGN GROUP, INC HULTZ BHU- C ROSS consulting engineers, Inc. 5 6 2407 North 31st Street Phone: (253) 383 -3257 genaralathultzbhucross,00m Tacoma, WA 98407 Fax: (253) 383 -3283 Job Humber. 08-091 PLUMBING PLANS 7 AND DETAILS BEN & JERRY'S KIOSK 8 SOUTHCENTER. MALL TUKWILLA , WA 10 REVISION DATE DATE JOB NO. 05.02.08 i08-043 PERMIT SET DRAWING NO. 2.0 7 of 9 7! HELIX DESIGN GROUP, INC.: Au rights reserved. 1 A B C ELECTRICAL LEGEND (SOME SYMBOLS MAY NOT BE USED ON DRAWINGS) SYMBOL XXX S EN 4 DESCRIPTION FIXTURE SYMBOL SINGLE POLE TOGGLE. SUBSCRIPT a, b, c, etc. INDICATES QUANTITY OF SWITCHES FOR SEPARATE CONTROL DISCONNECT SWITCH DUPLEX RECEPTACLE (NEMA 5 --20R) GEC! DUPLEX RECEPTACLE (NEMA 5 -20R) ASTERISK INDICATES COUNTER HEIGHT OUTLET (DUPLEX RECEPTACLE SHOWN) JUNCTION BOX - WALL EQUIPMENT CONNECTION SCHEDULED EQUIPMENT CONNECTION OR SYMBOL (INCLUDES FEEDER, DISCONNECT, STARTER, AND OTHER REQUIREMENTS AS SCHEDULED) PANELBOARD - FLUSH DRY TYPE TRANSFORMER CROSS LINES INDICATE NUMBER OF CONDUCTORS IF MORE THAN TWO WIRE CIRCUIT. LONG DENOTES NEUTRAL. DOT DENOTES GROUND. CONDUIT IS 1/2" AND CONDUCTOR IS #12 AWC UNLESS OTHERWISE NOTED OR SCHEDULED. DOTTED HASH MARK INDICATES ISOLATED .GROUND WIRING CONCEALED IN CEILING OR WALL WIRING CONCEALED BELOW FLOOR HOMERUN DATA (COMPUTER) OUTLET WITH JACK VOICE (TELEPHONE) OUTLET WITH JACK INDICATES QUANTITY 'OF VOICE AND DATA JACKS IN A SINGLE OUTLET NOTE: STANDARD LINE WEIGHT INDICATES EXISTING CONDITIONS. HEAVY LINE WEIGHT INDICATES NEW WORK. GENERAL ELECTRICAL NOTES: D 1. MINIMUM CONDUIT SIZE FOR HOMERUNS SHALL BE 3/4 INCH. 2. REFER TO ARCHITECTURAL PLANS FOR LIGHT BOX / DISPLAY BOARDS LOCATIONS. REFER TO INTERIOR ELEVATIONS, ROOM SECTIONS, AND DETAILS SHOWN ON ARCHITECTURAL CONTRACT DOCUMENTS PRIOR TO ROUGH -IN. 3. REFER TO ARCHITECTURAL ELEVATIONS FOR LOCATION AND MOUNTING HEIGHT OF WIRING DEVICES. 4. VERIFY EXACT LOCATION OF OUTLETS LOCATED IN KNEE SPACES AND CASEWORK. OBTAIN ARCHITECT APPROVAL PRIOR TO ROUGH -IN. 5. VERIFY BACK BOX REQUIREMENTS OF EQUIPMENT FURNISHED UNDER OTHER THAN DIVISION 16 SECTIONS AND EQUIPMENT FURNISHED BY OWNER. 6. ALL CONDUITS SHALL BE CONCEALED, UNLESS OTHERWISE NOTED. PROVIDE CUTTING AND PATCHING AS REQUIRED. LIGHTING CONTROL NOTES: (THE FOLLOWING NOTES REFERENCE APPLICABLE SECTIONS OF THE WASHINGTON STATE ENERGY CODE) 1. THE MAXIMUM LIGHTING LOAD CONTROLLED BY A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED 16 AMPS. (SECTION 1513.2) 2. PROVIDE SEPARATE CONTROL OF INDICATED DISPLAY, EXHIBITION, AND SPECIALTY LIGHTING INDEPENDENT OF GENERAL AREA UGHTING (SECTION 1513.4). C D E F G LIGHTI\GF1XTURE SCHEDULE SYM DESCRIPTION MANUFACTURER LAMP TYPE VOLTS VA /W REMARKS LED LED ACCENT TUBE, RECTANGULAR SEMI -RIGID CLEAR TUBING PROFILE, SINGLE STATIC CIRCUIT, GREEN 12V LED'S SPACED 3-INCHES ON CENTER. PROVIDE CLASS II TRANSFORMER, END CAPS AND MOUNTING HARDWARE. LENGTH AS SCALED ON PLANS. TIVOLI HB SERIES LED 120 1W/LF ©10K H J 1 SK EL CT IC L FL r -: `fix PL A SCRIM 1 /C®® 1 O' PLAN NOTES: 0 PROVIDE CONNECTION TO LIGHT BOX WITH GRAPHICS. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 0 PROVIDE CONNECTION TO ILLUMINATED PROMO DISPLAY. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 0 PROVIDE CONNECTION TO ILLUMINATED MENU BOARD. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 04 MOUNT LED LIGHTING IN TOE KICK. PROVIDE FOURPLEX OUTLET AND DATA ROUGH -IN OUTLET BOX BELOW COUNTER FOR ALL -IN -ONE PRINTER. VERIFY REQUIREMENTS PRIOR TO ROUGH-IN. 0 POINT -OF-- SERVICE DATA ROUGH -IN OUTLET BOX. VERIFY REQUIREMENTS PRIOR TO ROUGH-IN. K KITCHEN EQUIPMENT CONNECTION SCHEDULE . SINGLE PHASE PANEL SCHEDULE DESCRIPTION LOCATION ID: P1 Section: 1 OF 1 Location; KIOSK Endosure: . Voltage: Olsafated Q1vSS 120/208, 3W Gnd 200% Neutral Rating: D 100 Amps Assembly AIC: Main Lugs Main Breaker Thru Lugs Lugs MCA Rated © Flush ©10K °Surface QNEMA 3R © 022K QFeed ['Double 1 42K 1 NEMA 12/31 • °Service BY CODE I DESCRIPTION WAFFLE CONE MAKER VA BKR CKT PHASE CKT BKR VA DESCRIPTION CODE K ITEM 1E 1200 20 1 A 2 20 1560 ITEM 14E DIP CASE • KIOSK K K ITEM 1E 120/1 1200 20 3 B 4 20 1550 ITEM 14E K K ITEM 3 375 20 5 A 6 20 480 ITEM 15E 120/1 K K ITEM SE 375 20 7 8 8 20 150 RECPT R K ITEM 5E 1 19E KIOSK 600 20 9 A 10 20 360 RECPT R WATER HEATER 3000 40/2 11 B 12 20 .. 280 , . PROMO, MENU BOAROS KIOSK 1 /4HP L 120/1 3000 CORD AND PLUG 13 A 14 20 635 ITEM 11E x K ITEM 16E 480 20 15 B 18 20 SPARE X CORD AND PLUG K ITEM 15E 100 20 17 A • 18 20 SPARE TYP OF 2 K ITEM 17E 1 /5HP 415 20 19 0 20 CORD AND PLUG SPACE A e 'PHASE REFRIGERATOR 8.3 7.5 KVA CONNECTED f LOAD SUMMARY TOTAL LOAD KVA AMPat Code Description KVA KVA CONNECTED 15.8 76.0 L Lighting 0.3 X 125% 0.4 CALCULATED 12.7 61.2 R Receptacles 0.5 X 100% 0.5 KIOSK 1 /5HP 4 R Receptacles over 1010VA 0.0 X 50% 0.0 X CORD AND PLUG C Computers 0.0 X 100% O.0 SPAN CAPACITY: 38.8% M Motors 0.0 X 100% 0.0 LM Largest Motor 0.0 X 125% 0.0 REMARKS: 40 FUDGE WARMER K Kitchen 9.0 X 55% 5.8 3.5 120/1 N Noncainck[ent 0.0 X 0% 0.0 CORD AND PLUG W Water Heater 0.0 X 125% 0.0 Remainder . 6.0 X 100% 6.0 H J 1 SK EL CT IC L FL r -: `fix PL A SCRIM 1 /C®® 1 O' PLAN NOTES: 0 PROVIDE CONNECTION TO LIGHT BOX WITH GRAPHICS. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 0 PROVIDE CONNECTION TO ILLUMINATED PROMO DISPLAY. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 0 PROVIDE CONNECTION TO ILLUMINATED MENU BOARD. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. 04 MOUNT LED LIGHTING IN TOE KICK. PROVIDE FOURPLEX OUTLET AND DATA ROUGH -IN OUTLET BOX BELOW COUNTER FOR ALL -IN -ONE PRINTER. VERIFY REQUIREMENTS PRIOR TO ROUGH-IN. 0 POINT -OF-- SERVICE DATA ROUGH -IN OUTLET BOX. VERIFY REQUIREMENTS PRIOR TO ROUGH-IN. K KITCHEN EQUIPMENT CONNECTION SCHEDULE . SYMBOL DESCRIPTION LOCATION MAXIMUM RATINGS FEEDER intit1213 EACH P HASE, , LUS GROU=ND UNLESS OTHERWISE INDICATED BELOW DISCONNECT CONTROL REMARKS • SIZE FLA MCA VOLT /PH BY DESCRIPTION STARTER r SPEED CONTROL, Q Cri w BY DESCRIPTION 0 WAFFLE CONE MAKER KIOSK 1200W 10 120/1 X CORD AND PLUG TYP OF 2 0 DIP CASE • KIOSK 1 /3HP 3.1 120/1 X CORD AND PLUG TYP OF 2 0 CASH REGIS iER KIOSK 500W 4.2 120/1 X CORD AND PLUG 9E WATER HEATER KIOSK 6KW 28.8 208/1 1 "C2 #8 + #10G 6 30A/2P NON FUSED 0 ICE MAKER KIOSK 1 /4HP 5.3 120/1 X CORD AND PLUG T j �UNDERCOUNTER BLENDER KIOSK 1560W 13 120/1 X CORD AND PLUG TYP OF 2 KIOSK 1 /5HP 4 120/1 X. CORD AND PLUG REFRIGERATOR . f • 16E UNDERCOUNTER REFRIGERATOR KIOSK 1 /5HP 4 120/1 X CORD AND PLUG 40 FUDGE WARMER KIOSK 415W 3.5 120/1 X CORD AND PLUG 18E WAFFLE DIP WARMER KIOSK 100W 0.8 120/1 X CORD AND PLUG 19E DIGITAL SCALE . KIOSK 100W 0.8 120/1 X CORD AND PLUG EQUIPMENT CONNECTION SCHEDULE NOTES: 1. VERIFY VOLTAGE, PHASE, FLA /MCA OF EACH CONNECTION WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. NOTIFY ARCHITECT /ENGINEER . WHEN SCHEDULED SUPPLY WILL NOT MEET NEC REQUIREMENTS. 2. LOCATION OF OUTLETS, DISCONNECTS, CONTROL DEVICES, AND EQUIPMENT CONNECTIONS ARE DIAGRAMMATIC AND TO BE LOCATED IN FIELD BY THE CONTRACTOR AS APPROVED BY THE ARCHITECT. UNLESS OTHERWISE INDICATED ON PLANS, INSTALL SCHEDULED DISCONNECTS AND CONTROL DEVICES INSIGHT OF EQUIPMENT. ARRANGE WIRING AND EQUIPMENT TO AVOID INTERFERENCE WITH OTHER WORK AND TO MAXIMIZE ACCESSIBILITY FOR MAINTENANCE AND REPAIRS. 3. WIRING BETWEEN EQUIPMENT DISCONNECT AND POINT OF CONNECTION SHALL COMPLY WITH NEC BASED ON EQUIPMENT NAMEPLATE RATING EXCEPT MINIMUM BRANCH CIRCUIT RATING Si -WALL BE 20 AMPERES. 4. WIRING SIZES ARE BASED ON 60 DEGREE C. FOR AMPACITIES 100 AMPERES AND LESS. FOR FEEDERS LESS THAN 100 FEET IN LENGTH, CONDUCTOR SIZES MAY BE SELECTED BASED ON 75 DEGREE .C. WHERE EQUIPMENT INSTALLED IS LABELED FOR 75 DEGREE C. WIRING. 5. SCHEDULE LEGEND: W FURNISH AND INSTALL NEW UNDER DIVISION 16 0 = INSTALL UNDER DIVISION 16; FURNISHED WITH EQUIPMENT OR BY OTHERS x = FURNISH AND INSTALL BY OTHERS (NOT DIVISION 16) * = EXISTING, RELOCATED EQUIPMENT. E F �Vv REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUN 3 0 2008 City Of Tukwila ILDING DIVI ION RECEIVED CITY OF TUKWILA JUN 2 5 Zoos PERMIT CENTER HULTZ fes C ROSS consulting engineers, inc. 2407 North 31st Street Phone: (253) 383 -3257 general @hultzbhucross.com Tacoma, WA 98407 Fax: (253) 383 -3283 Job Number: 08 -091 1 f 1 2 3 4 5 6 d s1gilin jircLJF AMERICAN INSTITUTE OF ARCHITECTS EXPIRES: 4/27/I0 HELIX DESIGN GROUP, INC ELECTRICAL PLANS AND 7 SCHEDULES BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL TUKWILLA , WA REVISION DAI 9 DATE 05.02.08 JOB N( iO8 -04; PERMIT SET '° E100 DRAWING NO. 8 of 9 G?r I.JKI IV nrcinhI rani in i r . .. . . 1 2 5 6 7 9 10 A A B B 0 D SECTION 16010 -- ELECTRICAL GENERAL PROVISIONS 1. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ADDENDA AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. ELECTRICAL, ARCHITECTURAL, PLUMBING AND ALL OTT -TER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS SHALL BE DEFINED AS THE CONTRACT DOCUMENTS. CONTRACTOR SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS PRIOR TO BIDDING. 2. VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH THE CONDITIONS AFFECTING THE INSTALLATION, SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. 3. "CONTRACTOR' AS USED WITHIN THE CONTEXT OF THE ELECTRICAL CONTRACT DOCUMENTS SHALL EXPLICITLY REFER TO THE "ELECTRICAL CONTRACTOR" AND THE ELECTRICAL CONTRACTOR'S "SUBCONTRACTOR ". THE TERM • "FURNISH" SHALL MEAN TO SUPPLY AND DELIVER TO NE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. THE TERM INSTALL" SHALL MEAN WORK WHICH INCLUDES THE ACTUAL UNLOADING, UNPACKING, ASSEMBLY, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS. THE TERM "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. THE TERM "EQUAL" SHALL MEAN TO MEET OR EXCEED THE STANDARDS OF THE SPECIFIED PRODUCTS OR LISTED MANUFACTURERS. 4. INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND PERMITS NECESSARY FOR THE PROPER COMPLETION OF ALL ELECTRICAL WORK SHOWN. ITEMS OMITTED, BUT NECESSARY, TO MAKE THE ELECTRICAL SYSTEMS COMPLETE AND WORKABLE SHALL BE UNDERSTOOD TO FORM PART OF THE WORK, SECURE AND PAY FOR PERMITS AND INSPECTIONS REQUIRED FOR ELECTRICAL WORK. 5. IT IS THE PURPOSE OF THE ELECTRICAL DRAWINGS TO INDICATE THE APPROXIMATE LOCATION OF ALL EQUIPMENT, DEVICES, ETC. ASCERTAIN EXACT LOCATIONS AND ARRANGE WORK ACCORDINGLY, THE RIGHT IS RESERVED TO EFFECT REASONABLE CHANGES IN THE LOCATION OF DEVICES UP TO THE TIME OF ROUGHING -IN, WITHOUT ADDITIONAL COST TO THE OWNER, CHANGES IN LOCATION OF DEVICES RESULTING FROM THE CONTRACTOR'S FAILURE TO COMPLY WITH THE CONTRACT DRAWING OR SPECIFICATION REQUIREMENTS SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 6. WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF LOCAL AND STATE CODES, AS WELL AS THE NATIONAL ELECTRICAL CODE (NEC), AS INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION. OBTAIN AND PAY FOR REQUIRED PERMITS AND INSPECTIONS. 7. CONSULT THE DRAWINGS, PRODUCT DATA AND SHOP DRAWINGS COVERING THE WORK FOR VARIOUS OTHER TRADES, THE FIELD LAYOUTS OF THE CONTRACTORS FOR THE TRADE AND MAKE ADJUSTMENTS ACCORDINGLY IN LAYING OUT THE ELECTRICAL WORK. 8. WARRANT NAT EQUIPMENT AND ALL WORK I5 INSTALLED IN ACCORDANCE WITH GOOD ENGINEERING PRACTICE AND THAT ALL EQUIPMENT WILL MEET . THE REQUIREMENTS SPECIFIED.' GUARANTEE AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS. REPAIR OR REPLACE ANY DEFECTIVE WORK, MATERIAL OR EQUIPMENT WITHIN ONE YEAR FROM DATE OF FORMAL WRITTEN ACCEPTANCE BY NE OWNER. 9. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. WHERE ONLY ONE MAKE IS NAMED, IT SHALL BE PROVIDED. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ARCHITECT, ENGINEER OR OWNER. 10. EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW AND U.L. LABELED FOR THE APPLICATION. 11. PREPARE SHOP DRAWINGS AND PRODUCT DATA FOR LIGHTING FIXTURES, LOADCENTER, AND ALL OTHER SPECIFIED SYSTEMS AND COMPONENTS. THE SUBMITTALS SHALL BE SENT DIRECTLY TO THE OWNER FOR REVIEW. THE SUBMITTALS THAT ARE RETURNED SHALL BE USED FOR PROCUREMENT. .WHERE ADDITIONAL INSTALLATION DRAWINGS, WIRING DIAGRAMS OR OTHER DRAWINGS ARE SPECIFIED AS PART OF NE SUBMITTAL, THEY SHALL BE SUBMITTED AT THE SAME TIME WITH SHOP DRAWINGS AND PRODUCT DATA. 12. THE CONTRACTOR SHALL KEEP ONE COMPLETE SET OF THE CONTRACT DRAWINGS ON NE PROJECT SITE ON WHICH SHALL BE RECORDED ANY DEVIATIONS. OR CHANGES FROM SUCH CONTRACT DRAWINGS MADE DURING CONSTRUCTION. THE UPDATED CONTRACT DRAWINGS SHALL BECOME `RECORD DRAWINGS" OF THE COMPLETED CONSTRUCTION. AFTER THE PROJECT IS COMPLETED, THE RECORD DRAWINGS SHALL BE DELIVERED TO THE ARCHITECT IN GOOD CONDITION, AS A PERMANENT RECORD OF NE INSTALLATION AS CONSTRUCTED. 13. PROVIDE NAMEPLATES ON LOADCENTER, SAFETY SWITCHES, AND SYSTEM DISTRIBUTION JUNCTION BOXES AND PULL BOXES, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. LETTERING SHALL INCLUDE THE NAME OR DESIGNATION OF EQUIPMENT, VOLTAGE RATING AND SERVICE DESIGNATION. NAMEPLATES FOR PANELBOARDS SHALL BE LAMINATED PHENOLIC WITH A BLACK SURFACE AND WHITE CORE. NAMEPLATES FOR BOXES, CONDUIT, ETC., SHALL BE HIGH QUALITY ADHESIVE TYPE OR PERMANENT MARKER. IDENTIFICATION IMN A 'DYMO TYPE INSTRUMENT IS NOT PERMISSIBLE. NE INSIDE COVER OF ALL RECEPTACLE COVERPLATES SHALL BE PERMANENTLY MARKED TO INDICATE THE PANEL AND CIRCUIT NUMBER OF THE RECEPTACLE. THE OUTSIDE OF THE COVERPLATES FOR ALL JUNCTION BOXES SHALL BE PERMANENTLY MARKED TO INDICATE THE SYSTEM. IDENTIFICATION SHALL BE ON THE INSIDE OF COVERPLATES FOR ALL JUNCTION BOXES IF THEY ARE LOCATED IN FINISHED AREAS. IDENTIFICATION OF BRANCH CIRCUITS SHALL BE TYPEWRITTEN ON 'DIRECTORY CARDS FURNISHED WITH NE LOADCENTER AND PLACED IN THE CARD HOLDER ON THE DOOR. 14. IDENTIFY SPARE CONDUITS AND CONDUIT STUBS AS FOLLOWS: IDENTIFY SYSTEM AND /OR PURPOSE AT SOURCE, IF POSSIBLE, AND AT TERMINATION END. ALSO, AT TERMINATION END, INDICATE LOCATION OF CONDUIT ORIGINATION. 15. AFTER INSTALLATION, TEST FOR GROUNDS, SHORT CIRCUITS AND PROPER FUNCTION OF EACH NEW SYSTEM AND RELATED WIRING. FAULTS IN THE INSTALLATION SHALL BE CORRECTED. 16. INSULATION RESISTANCE TEST SHALL BE MADE ON THE NEW ELECTRICAL SYSTEM WITH AN APPROVED MEG . OHMMETER. 17. A GROUND CONTINUITY TEST SHALL BE MADE ON THE ENTIRE GROUNDING SYSTEM FROM THE SERVICE TO EVERY NEW OUTLET. 18. AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN COMPLETED, CLEAN ALL EQUIPMENT LEAVING EVERYTHING IN WORKING ORDER AT THE COMPLETION OF THIS WORK. 19. ALL CUTTING AND PATCHING IN CONSTRUCTION AS NECESSARY FOR INSTALLATION OF THIS WORK SHALL BE THE RESPONSIBILITY OF THIS DIVISION. HAVE CUTTING DONE BY SKILLED MECHANICS AS CAREFULLY AS POSSIBLE AND WITH AS LITTLE DAMAGE AS POSSIBLE. 0 D E F G SECTION 16050 -- ELECTRICAL BASIC MATERIALS AND METHODS 1. CONTRACTOR SHALL PROVIDE JUNCTION BOXES AND COVERPLATES SUITABLE FOR THE APPLICATIONS, RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE INDEPENDENT OF THE CONDUIT SYSTEM. TO ACCOMMODATE BRANCH CIRCUITING SHOWN ON THE DRAWINGS AND TO COMPLY WITH THE NEC. ALL BOXES SHALL BE 4 INCH X 4 INCH X 2 INCH DEEP MINIMUM WITH COVERPLATES SUITABLE FOR THEIR INTENDED USE. BOX STABILIZERS SHALL BE UTILIZED TO PROPERLY SUPPORT BOXES IN METAL STUD CONSTRUCTION. 2. ALL INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT), UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS. CONDUITS SHALL BE 3/4 INCH TRADE SIZE, MINIMUM, UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS. ALL EMT CONDUITS SHALL HAVE COLD - ROLLED STEEL DOUBLE SET SCREW FITTINGS. 3. METAL CLAD (TYPE MC) CABLE MAY BE UTILIZED IN LIEU OF BRANCH CIRCUIT EMT CONDUIT IN CONCEALED SPACES. WIRING SHALL BE AS SPECIFIED ELSEWHERE IN THIS SECTION. A GREEN EQUIPMENT GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL MC CABLE. 4. LOCAL LIGHT SWITCHES SHALL BE 20 AMPERE, 120/277 VOLTS, AC SPECIFICATION GRADE, WITH GROUNDING TERMINAL -- HUBBELL #HBL -122. 5. DUPLEX RECEPTACLES SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING GENERAL PURPOSE 'SPECIFICATION GRADE ". 6. DUPLEX RECEPTACLES WHERE INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE, SHALL HAVE INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AND SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING: HUBBELL #GH5352. GFCI RECEPTACLES SHALL NOT BE THROUGH- WIRED. PROVIDE INDIVIDUAL DUPLEX GFCI RECEPTACLES AS SHOWN ON THE DRAWINGS. 7. ALL RECEPTACLES SHALL BE PROVIDED WITH A SELF - GROUNDING CLIP AT THE MOUNTING SCREW. 8. ALL SWITCHES, DIMMERS, AND RECEPTACLES SHALL BE WHITE UNLESS OTHERWISE INDICATED WITHIN THESE SPECIFICATIONS. VERIFY COLOR WITH THE ARCHITECT PRIOR TO PROCUREMENT OF THE DEVICES. ALL COVERPLATES SHALL BE SMOOTH HIGH IMPACT COMMERCIAL GRADE THERMOPLASTIC OR SMOOTH NYLON FINISH WITH COLOR TO MATCH THE. DEVICES. BOTH THE WIRING DEVICES AND THE COVERPLATES SHALL BE BY THE SAME MANUFACTURER. 9. EQUIVALENT "SPECIFICATION GRADE" RECEPTACLES: #5362 SERIES MANUFACTURED BY PASS AND SEYMOUR, COOPER OR LEVITON. FOR OTHER TYPES OF RECEPTACLES SPECIFIED THE EQUIVALENT SERIES BY PASS AND SEYMOUR, COOPER OR LEVITON SHALL BE ACCEPTABLE. 10. EQUIVALENT LIGHT SWITCHES: PASS AND SEYMOUR #20AC SERIES, COOPER #222 SERIES OR LEVITON #122 SERIES. 11. WIRE AND CABLE FOR BRANCH CIRCUITS SHALL BE 90 DEG C, 600 VOLT, TYPE THHN /THWN, COPPER ONLY, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. MINIMUM SIZE FOR POWER AND LIGHTING BRANCH CIRCUITS SHALL BE #12. ALL 600 VOLT WIRING SHALL BE IN CONDUIT, 12. SAFETY SWITCHES SHALL BE HEAVY DUTY FUSIBLE OR NONFUSIBLE TYPE AS INDICATED ON THE DRAWINGS, AND SHALL BE SUITABLE FOR THE VOLTAGE AND CURRENT RATINGS AS SHOWN ON THE DRAWINGS. 13. DISCONNECT SWITCHES SHALL BE MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS /ITE, OR CUTLER HAMMER /WESTINGHOUSE, 14. CONDUITS SHALL BE CONTINUOUS AND SECURED TO ALL BOXES IN SUCH A MANNER THAT EACH CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS FROM , THE POINT OF SERVICE TO ALL DEVICE BOXES. RUN CONDUITS CONCEALED UNLESS OTHERWISE INDICATED. THE ACTUAL ROUTING OF CONDUITS SHALL BE INSTALLED TO SUIT THE VARIOUS FIELD CONDITIONS. 15. INDIVIDUAL BRANCH CIRCUITS ARE SHOWN ON THE DRAWINGS FOR CLARITY. UGHTING AND RECEPTACLE CIRCUITS MAY BE GROUPED FOR HOMERUNS, WITH A MAXIMUM OF TWO (2) CIRCUITS PER HOMERUN. NEUTRAL CONDUCTORS IN RECEPTACLE CIRCUITS SERVING DATA EQUIPMENT LOADS SHALL NOT BE SHARED. 16. FOR 120 VOLT BRANCH CIRCUITS WHERE SIZE IS NOT SHOWN, CONDUCTOR SIZE #12 MINIMUM SHALL BE USED FOR ALL CIRCUITS. 17. IDENTIFY WIRE AND CABLE FOR BRANCH CIRCUITS AS CALLED FOR IN THE NATIONAL ELECTRICAL CODE. 18. ADJACENT DEVICES OF THE SAME VOLTAGE CLASS SHALL BE MOUNTED IN GANGED BOXES. 19. MOUNTING HEIGHTS TO THE CENTER OF OUTLET BOXES SHALL BE AS INDICATED ON THE DRAWINGS. 20. VERIFY MOUNTING HEIGHTS AND LOCATIONS WITH THE ARCHITECT AND KITCHEN EQUIPMENT SUPPLIER BEFORE ROUGH-IN. REFER TO DETAILS AND INTERIOR WALL ELEVATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. 21. ALL RECEPTACLES SHALL BE MOUNTED WITH THE GROUND OPENING ABOVE THE PHASE AND NEUTRAL OPENINGS. 22. ALL DEVICES SHALL BE SECURED WITH MORE THAN A SINGLE SCREW. 23. ALL HARDWARE, SUPPORTS, AND CLAMPS NECESSARY TO INSTALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED TO SUIT THE FIELD CONDITIONS AND NE APPLICATIONS INTENDED AS SHOWN ON THE DRAWINGS. THE USE OF PERFORATED STRAPS IS NOT PERMITTED, E F G H J SECTION 16400 - POWER DISTRIBUTION 1. THE ELECTRICAL SERVICE TO THE KIOSK SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. 2. GROUND ALL ELECTRICAL SYSTEM CONDUITS, RACEWAYS, LOADCENTER, CABINETS, FIXTURES, METAL BOXES, AND OTHER EXPOSED NON- CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NEC, STATE BUILDING CODE AND LOCAL OR REGIONAL CODES. 3. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH FEEDER AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS, SIZED IN ACCORDANCE WITH NEC ARTICLE 250.122. 4. WHERE GROUNDING CONDUCTORS ARE SUBJECT TO MECHANICAL DAMAGE PROTECT SUCH CONDUCTORS BY ENCASEMENT IN CONCRETE OR INSTALLATION IN A RIGID METALLIC RACEWAY. 5. ALL TERMINATIONS OF THE GROUNDING CONDUCTORS SHALL BE BY MEANS OF SOLDERLESS CONNECTIONS. 6. FURNISH AND INSTALL A BRANCH CIRCUIT BREAKER LOADCENTER EQUIPPED WITH CIRCUIT BREAKERS, WITH FRAME AND TRIP RATINGS LISTED ON THE DRAWINGS. CIRCUIT BREAKERS SHALL BE THERMAL - MAGNETIC, MOLDED CASE BOLT -ON TYPE. ALL CURRENT CARRYING PARTS OF THE BUS STRUCTURE SHALL BE TIN -- PLATED ALUMINUM. EACH LOADCENTER SHALL CONTAIN A 100% RATED NEUTRAL BUS AND A GROUNDING BUS. PANELS SHALL HAVE "DOOR- WITHIN -DOOR" TRIM, HINGED BOX TO FRONT TYPE. WITH LOCK ON INNER DOOR. ALL LOCKS SHALL BE KEYED ALIKE. 7. THE LOADCENTER, AS A COMPLETE UNIT, SHALL HAVE A MINIMUM SYMMETRICAL SHORT CIRCUIT CURRENT RATING OF 10,000 AMPERES. CIRCUIT BREAKERS SHALL. BE FULLY RATED. SERIES RATINGS ARE NOT PERMITTED. 8. THE LOADCENTER SHALL BE AS MANUFACTURED BY SQUARE D, SIEMENS /ITE, GENERAL ELECTRIC OR CUTLER HAMMER /WESTINGHOUSE. 9. THE LOADCENTER SHALL BE MOUNTED AS HIGH AS POSSIBLE ON THE HALF - HEIGHT WALL, AS SHOWN ON THE DRAWINGS. SEE THE ARCHITECTURAL ELEVATIONS FOR DETAILS. A GLAZED DIRECTORY FRAME SHALL BE PROVIDED INSIDE THE LOADCENTER DOOR AND SHALL BE OF SUFFICIENT SIZE TO GIVE A COMPLETE DESCRIPTION OF EACH CIRCUIT. TYPED DIRECTORY CARDS SHALL BE PROVIDED LISTING EACH CIRCUIT SERVED. 10. THE BRANCH CIRCUIT NUMBERS USED ON THE DRAWINGS SHALL BE APPLIED FOR THE CONSTRUCTION. HOWEVER, AT THE COMPLETION OF THE WORK, CIRCUIT NUMBER ADJUSTMENTS SHALL BE MADE AS REQUIRED TO PROVIDE BALANCED PHASE LOADING ON THE LOADCENTER. 11. SPARE CIRCUIT BREAKERS SHALL BE IDENTIFIED AS SUCH ON THE PANEL DIRECTORY CARDS AND SHALL BE LEFT IN THE "OFF" POSITION. SECTION 16500 - LIGHTING 1. LIGHTING FIXTURES SHALL BE PROVIDED AS SPECIFIED IN THE LIGHTING FIXTURE SCHEDULE, OR AS INDICATED ON THE DRAWINGS. CONTRACTOR 15 RESPONSIBLE FOR PROVIDING PROPER MOUNTING ACCESSORIES. CONTRACTOR SHALL REFER TO THIS SPECIFICATION FOR LAMP REQUIREMENTS. SUBMITTALS SHALL INCLUDE PRODUCT INFORMATION FOR FIXTURES AND LAMPS. 2. ALL LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, SYLVANIA OR PHILIPS. 3. SURFACE MOUNTED FIXTURES MOUNTED ON CEILINGS OTHER THAN ACCESSIBLE LAY -IN CEILING SYSTEMS, OR TO NE BUILDING STRUCTURE, SHALL BE SECURELY SUPPORTED IN A MANNER BY THE ARCHITECT. 4. SPARE LAMPS AMOUNTING TO 10% (MINIMUM OF 3) OF EACH TYPE AND SIZE OF EACH LAMP USES ON THE PROJECT SHALL BE SUPPLIED BY THE ELECTRICAL CONTRACTOR. 5. UGHTING FIXTURE SHALL BE INSTALLED ON ACCORDANCE WITH NEC ARTICLE 410. SECTION 16700 - COMMUNICATIONS 1. VOICE AND DATA OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH SINGLE GANG PLASTER RINGS. BLANK COVERPLATES SHALL BE PROVIDED FOR ALL UNUSED OUTLETS. VERIFY EXACT REQUIREMENTS WITH .THE OWNER'S TECHNOLOGY SYSTEM SUPPLIER PRIOR TO INSTALLATION. 2. ALL CONDUITS REQUIRED FOR COMBINATION VOICE AND DATA OUTLETS AS SHOWN ON THE DRAWINGS SHALL BE INSTALLED COMPLETE WITH PULLWIRES. CONDUITS SHALL BE 1" MINIMUM. 3. PROVIDE CONDUIT FROM EACH OUTLET TO THE NEAREST ACCESSIBLE SPACE AND PROVIDE AN INSULATED BUSHING AT EACH STUB. H C-1,0 J K RECEIVED CITY OF TUKIMLA JUN 2 5 /UM PERMIT CENTER HULTZ C ROSS consulting engineers, Inc. 2407 North 31st Street Phone: (253) 383 -3257 general©hultzbhucross.com Tacoma, WA 98407 Fax: (253) 383 -3283 Job Number: 08-091 K 1 2 3 4 5 I r rQU� AMERICAN INSTITUTE OFARCI-IITECfS EXP RI : 4 /27/iD HELIX DESIGN GROUP, INC ELECTRICAL SPECIFICATIONS 7 BEN & JERRY'S KIOSK 8 SOUTHCENTER MALL TUKWILLA , WA REVISION DA-1 9 DATE 05.02.08 JOB NC i0&O4: PERMIT SET 10 E200 DRAWING NO. 9of9 L© HEM DESIGN GROUP, INC.: Al rights reserve Ile part r f this dement may he reproduced in an form or any meats r+Bhottt permission In Mtfng from Helix tiesfgrt Ora