Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0551 - WESTFIELD SOUTHCENTER MALL - VITAMIN WORLD
VITAMIN WORLD 1119 SC MALL 07-21-08 ELO8-55 1 City,f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1119 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -551 Issue Date: 06/05/2008 Permit Expires On: 12/02/2008 Tenant: Name: VITAMIN WORLD Address: 1119 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KENT FAHEY Phone: 800 - 556 -8641 Address: 3019 HOLLINWELL DR , KATY TX Contractor: Name: ALLIED ELECTRIC SERVICE INC Phone: 360 459 -0575 Address: PO BOX 3855 , LACEY WA Contractor License No: ALLIEES145BC Expiration Date: 01/31/2010 DESCRIPTION OF WORK: ELECTRICAL INTERIOR TENANT IMPROVEMENT OF NEW MALL SPACE Value of Electrical: $10,000.00 Fees Collected: $307.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: L9 v oQ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or u performance of work. I am authorized to sign and obtain this electrical permit. Signature: .4 P • Name: E124( FIZE0C1 -1 Date: % 5 1DS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -551 Printed: 06 -05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 1119 SOUTHCENTER MALL TUKW Suite No: Tenant: VITAMIN WORLD Permit Number: EL08 -551 Status: ISSUED Applied Date: 05/12/2008 Issue Date: 06/05/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be m accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signaturcei„, Print Name: ML�1-1 Date: jQ 1 c /OS doc: Cond -Elec EL08 -551 Printed: 06-05 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. ci.1ukwila. wa. us Electrical Permit No. EL-O 5s1 Project No. 11°° 11(11 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION n King Co Assessor's Tax No.: LP3(QL -1, Z 0 -`00 k 0 Site Address: l 1 '{ � Suite Number: Tenant Name: Vtl- Nl( NCA2--1/4,4=> New Tenant: n Yes n.. No Property Owners Name: Mailing Address: Floor: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Mailing Address: E -Mail Address: Day Telephone: 9100-S0 - l . °o City (ate Zip Fax Nwnber:28i ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Lip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: Slate Valuation of Project (contractor's bid price): S (D 1 OCX-7 Scope of Work (please provide detailed information): (r-10112 Wr�t6' c — LIKCSrlh)cc t�-- Will service be altered? t Yes No Type of Use: Type of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ Yes No ❑ Service Change ❑ Fire Alarm 11: Apphtanun 1 omn- Appincunnns On 1 me 4. OO' F Intntdl Pcmm11 Application dot hit ❑ Remodel ❑ Telecommunication Tenant Improvement Temporary Service Pagc 1(ttz • 1 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5140.00 (including an attached garage) ❑ Garages, pools. spas and outbuildings $75.00 ca ❑ Low voltage systems (alarm, furnace thermostat) 555.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change 550.00 (up to 5 circuits) ❑ Circuits added/altered without service change S50.00 (6 or more circuits) 57.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI-FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ Temporary service (generator) 575.00 ❑ Manufactured/mobile home service S80.00 (excluding garage or outbuilding) ❑ Carnivals S75.00 Number of concessions S 10.00 ea PERMIT APPLICATION NOTES - Value of Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY TIIAT 1 IIAVE READ AND EXAMINED TIIIS APPLICATION AND KNOW TI IE SAME TO BE TRUE TINDER PENALTY OF PERJURY BY TIIE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPI.Y FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: dyr1 rc, ps Mailing Address: L3.8 z/1 ea. v- 77 /ay 163 Date Application Accepted: • * 0,4 II'.Appllealloni Form- Apphcaron.N Cht I.me'4I(5)? PItelncal P.rmn Appbca■on.ihn: hh Date Application Expires: Date: Day Telephone: cL 4.6?7 Se- till /e .A-- W) s1 State Zip City Staff Initials: Pagc 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -02410 Initials: WER User ID: 1655 Payee: JOSEPH M. MCINTYRE Payment Date: 07/03/2008 Total Payment: 118.00 SET ID: 0703 SET NAME: VITAMIN WORLD REVISIONS SET TRANSACTIONS: Set Member Amount C 8EL'0"551 58.00 M08 -139 60.00 TOTAL: 118.00 TRANSACTION LIST: Type Method Description Amount Payment Check 644 118.00 TOTAL: 118.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES 000.322.101.00.0 58.00 000.322.102.00.0 60.00 TOTAL: 118.00 4420 07/03 4711 TOTAL 118.00 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -551 Address: 1119 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/12/2008 Applicant: VITAMIN WORLD Issue Date: Receipt No.: R08 -01941 Initials: WER User ID: 1655 Payment Amount: $246.00 Payment Date: 06/04/2008 01:08 PM Balance: $0.00 Payee: ALLIED ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 27637 246.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 246.00 Total: $246.00 3239 06/04 9711 TOTAL 246.00 rinn• RpcAint -06 PrintArl- OR-04 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -551 Address: 1119 SOUTHCENTER MALL TUICW Status: PENDING Suite No: Applied Date: 05/12/2008 Applicant: VITAMIN WORLD Issue Date: Receipt No.: R08 -01563 Initials: WER User ID: 1655 Payment Amount: $61.50 Payment Date: 05/12/2008 12:01 PM Balance: $246.00 Payee: RETAIL PERMIT SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8876 61.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 61.50 Total: $61.50 2284 05/12 9711 TOTAL 734.78 doc: Receiot -06 Printed: 05-12 -2008 INSPECTION NO. INSPECTION RECORD r, „ 7 5(4 I 'U�' 8 Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: t j ,.l,J t40427 Type of Inspection: ..2.100 Address: ` ` ial .i . a, Date Called: Special Instruct ons: 1 Date Wanted: i �� a.m. P.m Requester: Phone No: TX Approved per applicable codes. Corrections required prior to approval. COMMENTS: Dri/JAI, Inspector: (f Date: b, fri Isc)q, ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit ttq-s-ci PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ''- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: i ITA(At 1A L 2 Type of Inspection: Address: ill tiff.R✓ Date Called: Special Instructi ns: Date Wanted: 1 6? m. Requester: Phone No: ElApproved per applicable codes. XCorrections required prior to approval. COMMENTS: 6040 To c..a 4 SEsstic.. , c,aveerfa ' — 5PAteg, V b5 Ca/.d 'f( 1Pre4 PPL 8 � c JIM DtSGoJ' &i ;C. o . x,4141 &rr 1 - 'Te.A.+JS,File_KEfk GitoosJDI4ci Inspector: ,1111 ocdtrb, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: / /0� g( Receipt No.: 'Date: ti INSPECTION NO. INSPECTION RECORD Retain a copy with permit ad3 - 5SI CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. iR (206)431 -3670 Project: , j (T� (� �Q � V L Type of Inspection: 005 Address: � I II 1 Date Called: Special Instructions: Date Wanted: 7 o1' Sn., Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: PA 4-0 Lip5 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: rate: - - . 4.71.,*.ta air• .c• ,y,.stb, ' 0446/ idifilAWAGSMetaingsAalbeckeissmi INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: f � ,uJ I �—A.A "�� �� Type of Inspection: ^� c/ D Address: � f ( � 7 4/l./ Date Called: Special Instructs ns: Date Wanted: alt/ /a.m. (2...3: Requester: Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: D, Inspector: L.ti 444M\ Date: 66/2..1 /A? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: 4...... . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 6100 —55[ PERMIT NO. (206)431 -3670 Project: V. ' r Type of Inspection: Address: ill OW/ Date Called: Special Instructi s: Date Wanted: % 6/ ly 'aL.m. m. Requester: Phone No: nApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: AMA\ IDate: OGI(gIA $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _ • . __3336 •• -=•..i ♦t ..r .�- •.arses._._ .+x•..we.i :v •4aamr :i...Q_ LUUzi VVdSLIIIIytull otatu 'MU' II CSIUCI Mal LAIC] yy vi n Li'giiting Summary tate Nonresidential Energy Code Compliance Forms LTG -SUM. Revised May 2005 Project Info Project Address \ 1i i� \VOY� t t-, 1}• '1 /'C H ` lul�T/ A.. Date 6.. 1 3 , 0 V lrfF1 664 , t 5cil r, Allowed x Area For Building Department Use - el Z 5 MA * Tu MA L ,u/ • Cb G%f�N Applicant Name: tot ZPP./ I r Applicant Address: S . G , 6 DN - -� vA. 7 %� Applicant Phone: �33 3. G . LEK 4t3 310 402 Project Description ❑ New Building ❑ Addition Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive Lighting Power Allowance 0 Systems Analysis (See Qualification hecklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. n Wattage (Interior Location (floor /room no.) Occupancy Description Allowed Watts per ft2*" Area in ft2 Allowed x Area 1 ETA I,I-- /-� obi att. t o A , I,, G) I.5 9 00 135 o 7 - (....re Si i --o1,- w all � s l Al z. - I . S 10 7 160,5 F -`te,c.1c - Ne -r'M� 1 AL -ire 70 SP ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1 Si 0 `S Proposed Lighting Wattage (Interior) Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed G -fir �� r c6Nrt 3 32 F Lo 7 1,t' / 4 U ftT - H H 9 Yi 'j51 VD , F -`te,c.1c - Ne -r'M� 1 AL -ire 70 SP TZ K- - MET2, L � jits*ED F So A l :' ®DE C ®Mt PENCE 0,2 W /ft2 C Outdoor Areas AD 0.2 W /ft2 RECEIV 01 2008 r_. JUL Bldg. (by perim)1 _ r-.,- irx.Q r "*"1 a II 11 a r?. e 7.5 W /If JUN 2 4 i r City of Tukwila DIVIS1oN .. BU DING Total Proposed Watts may not exceed T\PPROVE owe atts for Interior Total Proposed Watts 1 507 Maximum Allowed Lighting Wattage (Exterior NU.! Location ., v _ Description Allowed Watts per ft2 or per If Area in ft2 (or If for perimeter) Allowed Watts x ft2 (or x If) Covered Parking (standard paint) 0.2 W/ft2 Covered Parking (reflective paint) 0.3 W/ft 2 Open Parking 0,2 W /ft2 Outdoor Areas 0.2 W /ft2 RECEIV Bldg. (by facade)' 0.25 W /ft2 Bldg. (by perim)1 _ r-.,- irx.Q r "*"1 a II 11 a r?. e 7.5 W /If JUN 2 4 i ELO8 551 ED IJo8 PERMIT CENTER 2004 Washington state IVonresiaenuat cnGtyy uuue ;Jim Lighting Summary (back) 2004 Washington State Nonresidential Energy Code Compliance Forms LTG -SUM Revised May 2005 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified. do LPA Calculations. Lighting Fixtures: ( Section 1521) Check if all fixtures are ballasted and at least 95 %• of fixtures are either: 1. Fluorescent fixtures which a) are non - lensed. b) have 1 or 2 two lamps c) have 5 60 watt T -1, T -2, T-4, T -5, T -6, T -8 lamps. d) have hard wired electronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts ' - Exit and LED lights can be excluded from count if < 5 watts /fixture. I /.113L I - 1 Urrrl 1-Iy1Iatiou . vv.,. .- ...v.......... Use' v-..., LPA` (W /sf)YUse' LPA` (W /sf) Painting, welding, carpentry, machine shops 2.3 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Barber shops, beauty shops 2.0 Police and fire stations' 1.0 2.0 Atria (atriums) 1.0 banquet/conference /exhibition hall3'4 _Hotel Laboratories 1.8 Assembly spaces', auditoriums, gymnasia', heaters 1.0 Aircraft repair hangars 1.5 Group R -1 common areas 1.0 Cafeterias, fast food establishments 1.5 Process plants 1.0 Factories, workshops, handling areas 1.5 Restaurants /bars5 1.0 Gas stations, auto repair shops' 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses ', storage areas 0.5 Libraries' 1_5 Aircraft storage hangars 0.4 Nursing homes and hotel/motel guest rooms 1.5 Retail10, retail banking 1.5 Wholesale stores (pallet rack shelving) Parking garages (see exterior lighting) Section 1532 Mall concourses 1.4 Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Plans Submitted for Common Areas Only' Laundries 1.2 Main floor building lobbies' (except mall concourses) 1.2 Medical Offices, Clinics" 1.2 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.20 w /ft2 may be used. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) isplay window illumination installed within 2 feet of the window, provided that the display window is separated from the etail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the • lowing: located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. s additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 12) Medical and clinical offices include those facilities which, although not providing overnight patient care, do provide medical, dental, or psychological examination and treatment. These spaces include, but are not limited to , laboratories and treatment centers. LVVq VVdSnlnymni °taww i' ut a uueIIUdu Cticl yy L'UUC 1+U(IIFAlallt.c rUllll Lighting Permit Plans Checklist LTG -CHK Nonresidential Energy Code Forms Revised May 2005 2004 Washington State Project Address ‘4_t /Compliance eF j G,/y �� j �^ t �{ y(+ 1 f/4 Vora-) y .„ ii 1 i /�/l.I i f ! (.G+TV f t+r� Y1. Date / , 13 , t/` ,f ? C The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 2004 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control /access Schedule with type, indicate locations GL 2 � yes 1513.2 Area controls Maximum limit per switch E2` 3 OA1513.3 Daylight zone control Schedule with type and features, indicate locations NIA 1[ vertical glazing Indicate vertical glazing on plans NAoverhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls NA 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w /backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1.1A 1513.6.1 (a) occup. sensors Schedule with type and locations NAIndicate 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); size of zone on plans islA 1513.7 Commissioning Indicate requirements for lighting controls commissioning 1G G 6 Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture 1437 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency If "no" is circled for any question, provide explanation: JEROME M. ROTHENBERG I STATE OF WASHINGTON CITY OF TUKWILA - BUILDING DIVISION 2008 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2005 Washington Stem Nonmstdatl aI Energy Cade Carorar a farm. Revised My 2007 Project Info • ProledAddress AvititIN if/0R47 Date Si2040 Si 20404a 1119 Sodrah C tEIZ 414Lt ForBuild' FILE C�P� Pr° "re! 4 �o W h��e TOKWitA, W4 Applicant Name: ,i_ Remit_ EN G / 44o Q iNc, _rb c 1 Applicant Address: 7s0 R4,a0 ws =q6E BLvf, wesiteuk.6 oNlc Applicant Phone: 61 y _ SI 0_.2 3.23 Project Description ErNew Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning si'af trG E • plans Included requirements. Compliance Option I O Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Cheddlst (over). Indicate Prescriptive & LPA spaces dearly on plans.) Alteration Exceptions (check approprfate box -sea 11323) ❑ No changes are being made to thelighting ❑ Less than 80% of the fixtures new, Installed wattage not Increased, & space use not.changed. Maximum Allowed Lighting Wattage Location (floorfroom no.) Occupancy Descrption Allowed Wattsjer ft2 .. Area In ft Allowed x Area / Relit& SA-C1=S 4 (gA 1.5' 75'0,0 1 115-4 ? si'af trG E o.So isopc, 7S e / QTh(L SkccS A-(Z A. Ifr 7S'0ro . Jl2,s. o rem Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Walls 2,34S— .O Location (floor/room no.) - Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed / (441.1 ivauvc L 2XZ /0 6e2 . 6 20 / wti,4ec,aUvee ZX? __ a h2 . /2y I fiQfick L r6 , �.._..Pi VIFWFD. FOR /3 go S z 0 T A-c k NE41) O!E COMPI TANCE /8 / 2 6 Z STckfrrki 3 9 ( rRhc k N CA-.6 b 1 1 g lo S r Tuck if E40 1 F 200. i 6 0 Lap MAY @1 ______NO)-•-- City Of Tukwila 1 RI III um; DIVISION Total Proposed Watts ma Mbwed'011atts for Interior Total Proposed Watts) 2.&q Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the tbcture, and ballast type (if included). For tracc lighting, list the length of the track (In feet) in addition to the fbdure, lamp, and ballast Information. 2. For proposed WattssFbfiue, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other calieda as spedfled In Section 1530. For hand -wired ballad only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exernpt lighting, note section and exception number, and leave Watts/Fbcture blank. _ L. 0 8 5 1 new. pessouRainipmanalmenw RECEIVEr MAY .14 2008 PERMIT C€NTE= -r 1 CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary. (back) LTG -INT 2008 WaiRngtat Slate Nonresidential Energy code Compuarue Forma Revtted .cry 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other I Qualification Checklist Note: U occupancy type is some and mire answer Is checked, the number of IWures in the space Is not limited by Code. Clearly Indicate these spaces on Plans. If not qua5fled, do LPA Calculations. jghktrng Fbctures: (Section 1521) 0.9 ■ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or lowers, c) 5-60 watt T-1, T -2, T.4, T-5, T=8 lamps. and d) hard -wired oleo- tronlc dimming ballasts. Screw -in compact fluorescent fixtures do not quarry. 2. Metal Halide with a) reflector b) ceramic MH lamps <a 150w c) electronic ballasts 3. LED lights. - -1 Unit Lighting Power Allowance use LPA' (W /sfiLlser LPA'(Wief) Automotive facility 0.9 -Office bulldings, office/administrative areas It facilities of other use types (including but not limited to schools hospitals, Institutions, museums, banks, churches) W1 1.0 Convention center 1.2 Penitentiary and other Group f-3-Occupancies 1.0 Courthouse t2 Police anditre stations 1.0 Cafeterias, fast food establishments', restaurants/barss L3 Post office 1.1 Dormitory 1.0 Retail", retaWbanking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 Schooi buildings (Group E Occupancy only). school classrooms, day care centers 12 Gymnasia', asyembly spaces' 10 Theater, moon picture 12 Health care clbdc 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1-1 and 1 -2 Occupancies 12 Transportation 1.0 Ptotel/motel 1:0 Warehouses ". storage areas 0.5 Hotel banquet/conference/exlu-brtton hall; - 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory' shall meet office and other appropriate categories) 1.8 Farwng garages 0.2 Laundries 1.2 Libranes' 1.3 ubmitted for Common Areas only' Plane submitted/a- Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 12 Museum 1.1 Common areas, corridors, tollet tacrlrbes and washrooms, elevator lobbies 0.6 ootnotes for Table i5 -1 1) In cases In which a general use and a specific use are listed, the specific use shall apply. In cases In which a use Is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shag be based upon the most =parable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be Increased, by two percent per foot of calling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit lighting Power Allowance of 1.10 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area Is 2.60 W/ft2. 10) Display window Illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by wags or at least three- quarter - height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt An additional 1.5 wift2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) boated on ceing- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fbctures with two points of track attachment). c) lifted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This addi0onal lighting power Is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the Interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined In footnote 2 applies only to the floor area not covered by racks. • CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments. LTG -LPA 2008 Washington stale Shwas Mengel Energy Code Companies ferns Revlead July 2007 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for Interior lighting. he Occupancy Description should agree with the Use listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA Is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding °Allowed Watts per ft2' location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor/room no.) Occupancy Description Allowed Watts per ft2 " Ceiling Height for this room Celting Height limit for this exception" Adjusted LPA Watts per ft2 " From Table 15-1 based on exceptions listed In footnotes PERMIT COORD COPY a PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -551 DATE: 06 -24 -08 PROJECT NAME: VITAMIN WORLD SITE ADDRESS: 1119 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Building bci- Public Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n ta DETERMINATION OF/COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06 -26 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS ROUTING: Please Route ❑ Structural Review Required rn No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS R CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -24 -08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 *PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -551 DATE: 05 -12 -08 PROJECT NAME: VITAMIN WORLD SITE ADDRESS: 1119 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: _ 4f? Buih9 ni g Dion IF Public Works 111 Fire Prevention — Planning Division Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05 -15-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -1 2-08 Approved ❑ Approved with Conditions II Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: 55( ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: \% I. /z(,--nYt., Way- ( L Project Address: /11 �t css, � •, - r /774 /,' /2 Contact Person: & r k deled ,' ,c••Y,t Phone Number: 26G - (F-e 2 — e52 Summary of Revision: /,' /7 jJ p /eS RECE'vFi; PERM' I \d6..,. Sheet Number(s): 2-/ E 3 2 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on la -0k tapplicationstforms- applications on linelrevision submittal Created: 8 -13 -2004 v..a�a,r• Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License ALLIEES145BC Licensee Name ALLIED ELECTRIC SERVICE INC Licensee Type ELECTRICAL CONTRACTOR UB1 600599707 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 3855 Address 2 City LACEY County THURSTON State WA Zip 98509 Phone 3604590575 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/3/1986 Expiration Date 1/31/2010 Suspend Date Separation Date Parent Company Previous License ALLIEES156BZ Next License Associated License ELWINHJ974L4 Master Electrician Information License ELWINHJ974L4 Name ELWIN, H JOHN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date ELWIN, DIANE 01/01 /1980 • Bond Information Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ALLIEES 145BC 06/05/2008 RICHARD R. JENCEN ASSOCIATES POWER PLAN 1/4",i'-o" ELECTRICAL SYN BOLS ALL SYMBOLS DO NOT NECESSARILY APPLY SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED -e SF VIP D) GFI WIRED JUNCTION BOX RECESSED(FLOOR) DUPLEX RECEPTACLE, 20A SINGLE RECEPTACLE, 3 WIRE GRD. TYPE, 15A DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF, 20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A ISOLATED GROUND DUPLEX RECEPTACLE, 20A QUADRAPLEX WALL RECEPTACLE, 20A LIGHTING CONTACTOR TIME CLOCK (TIME SWITCH) PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH — SINGLE, 3 —WAY & 4—WAY MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET DATA OUTLET — CATEGORY 5 COMBINATION DATA /PHONE OUTLET SAFETY SWITCH COMBINATION STARTER /SAFETY SWITCH MOTOR OUTLET -- 1 PHASE MOTOR OUTLET -w 3 PHASE FIRE ALARM PULL STATION FIRE ALARM VISUAL SIGNAL DEVICE FIRE ALARM STROBE/HORN SIGNAL DEVICE DUCT MTD. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS SYSTEM HEAT DETECTOR (FIXED TEMP.) FIRE ALARM WATER FLOW SWITCH FIRE ALARM TAMPER SWITCH SYSTEM SMOKE DETECTOR RECESSED CEILING SPEAKER (PAGING /MUSIC /SECURITY) SEE DRAWINGS FLOOR AS REQUIRED CEILING MTD. 18" U.N.O. 18" 18" 18" 18" AS REQUIRED AS REQUIRED 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 48" 80" 80" AS REQUIRED CEILING MTD. AS REQUIRED AS REQUIRED CEILING MTD. CEILING MTD. NOTE: ELECTRICAL CONTRACTOR MUST VERIFY LOCAL CODES. "E" BY FIXTURE DENOTES FIXTURE IS EXISTING. Bulletin 3 Southcenter Mall - Tenant Design Criteria To: Southcenter Tenants Date: 5/16/2007 This Bulletin serves as the most up to date information regarding Electrical Design for all Tenant Improvement at the Southcenter Mall. The information below supersedes the information in the Tenant Design Criteria Manual dated March 2007. it is the responsibility of the Tenant to forward this information to the Tenant's Architect and Electrical Engineers. Electrical Design Criteria Landlord Work: 1. Change RMU's to 30A,120V,1 Phase, 3/4" Conduit [or Walker duct] 2. Change Retail Merchants, smaller than 3,000SF: 200A MC Cabling 3. Change ALL Retail, Dining Terrace and Restaurants to MC cabling, in lieu of conduit REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2008 !la DIVISION Fri t7 COPY Permit No. f(, b- i Plar review approval Is subject to errors and omissions. Appravn' of constructor documents does rmit aultiosze the violation of any adopted code or ordinance. Racelpt 01 approved Field Copy an ' conditions isie e°: By ..:_ . -' L! eif Date:, 7 `_ ? -- f City of Tukwila BUILDING DIVISION ! REviSiONS _ No changes shall be r�nTr e to'fhA seapP of work without prior approval of Tukwila Building Division. ' NOTE: Revisions will require a new plan submittal and may include additional plan re, &1.." fees. POWER PLAN CODED NOTES: 0 ELECTRICAL SER/ICE EQUIPMENT. SEE RISER DIAGRAM ON SHEET E -3 FOR MORE INFORMATION. ® PROVIDE TELEPHONE BACKBOARD WITH DEDICATED DUPLEX RECEPTACLE AS SPECIFIED ON SHEET E -4. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. ® PROVIDE TELEPHONE OUTLET, CONDUIT AND (2) CAT. 3 CABLE TO TELEPHONE BACKBOARD. SIZE AS REQUIRED BY TELEPHONE EQUIPMENT SUPPLIER, 1" MINIMUM, BUSH CONDUITS ENDS. • PROVIDE DATA OUTLET, 1" CONDUIT AND (2) CAT. 5 CABLE BACK TO OUTLET AT MANAGER'S DESK IN STOCKROOM. ONE CABLE SHOULD TERMINATE IN AN RJ45 JACK ON EACH END. ONE IN STOCK ROOM AND ONE IN CASHWRAP. SECOND CABLE IS A BACKUP. COORDINATE WITH CPU EQUIPMENT. ® PROVIDE DEVICES AS INDICATED AND MOUNT IN MILLWORK. VERIFY LOCATIONS AND COORDINATE WITH OWNER AND MILLWORK PRIOR TO INSTALLATION. ® RECEPTACLES AND COVERPLATES WITH AN "SF" DESIGNATION SHALL BE FLUSH MOUNTED IN CEILING AT STOREFRONT, PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. (NEC ART. 210 -62) ® 1" CONDUITS RUN UNDER FLOOR. CHANNEL AND PATCH FLOOR AS REQUIRED. COORDINATE CHANNELING WITH LANDLORD PRIOR TO STARTING WORK. v=i ELECTRONIC CASH REGISTER POWER SYSTEM. THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSES. THE CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CONDUIT FOR GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES. THE CIRCUITS FOR THE ELECTRONIC CASH REGISTERS SHALL BE RUN IN SEPARATE CONDUIT. ELECTRONIC CASH REGISTER OUTLETS SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL. THIS SYSTEM IS REQUIRED BY THE TENANT. ® COORDINATE EXACT STUB —UP LOCATIONS FOR CASHWRAP WITH MILLWORK. 10 r'rCU v1U� "r A4 J -6UA VVI I M rtAIJLU MIIU r INC7 ANU I,Ui luui 1 I U CA WRAP FOR DATA. MOUNT AT 54" A.F.F. SEE CODED NOTE #rrFOR ADDITIONAL INFORMATION. 11 1 /2" EMPTY CONDUIT WITH PULL STRING FROM THERMOSTAT TO UNIT IT SERVICES. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION. 12 PROVIDE TiME SWITCH: PARAGON MODEL 7000 —SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULING FORMAT, MIN. (4) N.O. 20 AMP 120/277 VOLT CONTACTS 120 VOLT COIL AND SPRING WOUND RIDE THROUGH. SWITCH SHALL CONTROL STORE FRONT SIGN LIGHTING AS INDICATED. RE —USE EXISTING WHERE APPLICABLE. VERIFY WORKING CONDITION. 13 REFER TO HVAC CONNECTION SCHEDULE FOR WIRING, CONDUIT, AND CIRCUIT REQUIREMENTS. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. 14 2 #12 AND 1 #12 GND FOR 1.5 KW TANK —TYPE WATER HEATER TO BE CIRCUITED TO PANEL A. 15 DUCT MOUNTED,SMOKE DETECTOR. FURNISHED AND WIRED BY TENANT E.C. INSTALLED BY MECHANICAL CONTRACTOR. E.C. SHALL FURNISH WITH REMOTE TEST /RESET SWITCH MOUNTED ON CEILING OR WALL BELOW UNIT. FIELD VERIFY EXACT LOCATION. VERIFY EXACT MODEL AND TYPE WITH LANDLORD TO ENSURE COMPATIBILITY WITH LANDLORD'S SYSTEM. E.C. SHALL VERIFY EXACT REQUIREMENTS WITH LANDLORD FOR CONNECTION TO THE LANDLORD'S SYSTEM AND INCLUDE ALL COSTS IN HIS BID. 1 SEPARATE PERMIT REQUIRED FOIE dMechanical 0/Electrical I ' Plumbing ud Gas Piping City of Tukwila f eii•.DINci DIVISION POWER GENERAL NOTES 1. REFER TO PLUMBING PLAN FOR LOCATION OF PLUMBING EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. 2. ELECTRICAL CONTRACTOR TO PROVIDE TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL CONDUITS SHALL BE CONCEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES. 5. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF RECEPTACLES, DATA /TELEPHONE OUTLETS AND OTHER DEVICES. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. REVISION NOLL EGOS- 5S1 RECEIVED JUN 2 4 2008 PERMIT CENTEF Emphasis On pence M• Retail Engineering, Inc. 750 Brooksedge Blvd_ Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com Project Design 1 Drawings Q 2PJ0i Jancen kcHtectire Original Pratotg7a Design ® 2006 Jancan Architectirs ARC HDTI ©TU. C R T L DEEM 2850 IMMO AVON ©LEMAD9 OR WIZ MOM 210.781.0131 GFANs 210.781000134 07 09 JUN 1 9 2003 in 1_, r ..n" gimi c■I co fly L CC _J Q o Q o Z O 1— a) c 5 ;: - IREVOSUOREIS E1 rivwrrrr■r�■■ POWER C R PLAKI DATE: 5/20/0S E i 0 JENCEN ASSOCIATES L IGW --WT INCA LEEN:D MANI,PACTURER PART No. DESCRIPTION LAMP QUANTITY F qCOOPER HALO STASIS POWER TRAC: L�1mP TRAGIC CERAMIC METAL HALIDE FLOOD 10 WATTS 1m WAIT t6 CMH 1� AA ERLU SD6- 39- T4- E- SDW -WP RECESSED DOU NLIGHT: METAL HALIDE fl.00D 39 WATTS 39 WATT T4 114 9 SP COOPER INALO STASIS POWER TRAG: L5m51620P- Llmmh'1B Ti7AGIC: CERAMIC METAL HALIDE WATTS WITH GI.IBE CELL LOUVERS 20 WAtt MR16 Ch1H 4 G METALUXX SN- 132- UNY- EI581 -U SURPACE MOUNTED STRIPLIGHT 32 WATT TS (48') 3 EX I-® HALLP)C1 W 4 LED EXIT W/ BATTERY BM 2 EN F I- IALCC3WH 2 -14EAD EMERGENCY 1 FAN FA51100L SYL100A9055XL130V COMM FAN/L IGHT 90 WATT 1 NOTE: ALL LIGHTS IN SALES AREA AND STOCK ROOM DESIGNATED WITH A LETTER 1=OLLOUJED SY '/NL' ARE TO BE WIRED A5 NIGHT LIGHTS (TYP. Of 3) LIGHTING PLAN KEY NOTED 0 EMERGENCY, EXIT AND NIGHT LIGHTS TO BE CIRCUITED TO A -1. O HOMERUN THROUGH TIME CLOCK. SEE POWER PLAN CODED NOTE #12. 0 HOMERUN THROUGH SWITCH 'a' LOCATED IN STOCK ROOM NEAR DOOR FOR GENERAL SALES LIGHTING, ® HOMERUN THROUGH SWITCH 'I' LOCATED IN STOCK ROOM NEAR DOOR FOR SALES TRACK LIGHTING, (-5-) HOMERUN THROUGH SWITCH "c' LOCATED IN STOCK ROOM NEAR DOOR FOR STOCKROOM LIGHTING, OB JUNCTION BOX AND DISCONNECT SWITCH FOR STOREFRONT SIGN PER NEC 600. E.C. SHALL PROVIDE ANY NECESSARY COMPONENTS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION. LIGHTING GENERAL NOTES 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. 4. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) WITH BATTERY BACKUP. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 6. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE USE OF THERMALLY PROTECTED LIGHTING WITH LOCAL CODES AND ORDINANCES. RECESSED LIGHT FIXTURES SHALL COMPLY WITH ARTICLES #410 -64; #410 -68 AND #410 -73 OF THE NATIONAL ELECTRICAL CODE REGARDING TEMPERATURE, CLEARANCE, CONSTRUCTION AND INSTALLATION. REVIEWED FOR— CODE COMPLIANCE APPROVED JUL 0 2008 City Of Tukwila BUILDIN DIVI ION (,0 55 ( FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING F1ELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. RECEIVEr JUN 2 4 2008 PERMIT CENTE - Emphasis On pence M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com Project Design 4 Drawings 2 Jen 2001 cen ArcHtect�re Original Prototccpe Design 2006 Jencan Ard9tectse d [n111 C YJI Ll E CT O E RETLaDL DIESMK 2850 CM©LO© adCM CLEVELAND, LAND, 0 1H0 405 PHONE 216.M.0131 FAL 218181204 JUN 1 9 20e3 L C CO 8 CiNg L 43 co o 09 Q C1) U c as 17)P a) 0) r r _ IRIEVOZOOKIS E2 FlolonTilimagomiss ILOGHTORIG PdAKI DATE: 5/20/0S 0' u RICHARD R. JENCEN ASSOCIATES ELECTRICAL CONNECTION SCHEDULE UNIT VOLTAGE FLA MCA VAV -1 208V, 3 PHASE 4.4 5.5 MOCP A/POLE 20/3 GROUNDED AND UNGROUNDED CONDUCTORS (3) #12 THWN & (1) #12 GND CONDUIT 3/4" SWITCH DISCONNECT AT UNIT CIRCUIT CONNECTION NOTES 30A, 3 -POLE, NONFUSED A-19/21/23 NOTE: VERIFY EXACT OVER CURRENT PROTECTION/DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. Bulletin 13 Southcenter Mall - Tenant Design Criteria To: Southcenter Tenants Date: 11/19/2007 This Bulletin serves as the most up to date information regarding the Temporary Power for Construction for all Tenant Improvement at the Southcenter Mall. The information attached supplements the information in the Tenant Design Criteria Manual dated March 2007, It is the responsibility of the Tenant to forward this information to the Tenant's Architects, Engineers, and Contractors. Temporary Power for Construction Each Tenant Contractor will complete their electrical installation to provide for a "Temporary to Permanent" Electrical Meter and service. The Landlord shall provide a main circuit breaker in a Landlord Electrical room and conduit and conductors (feeders) from the circuit breaker to a Landlord provided fused disconnect switch located within the Tenant space. The voltage supplied to the Tenant space will be 277/480v, unless otherwise indicated. Upon possession of the space, the Tenant shall install all electrical work necessary for a complete electrical distribution system within the premises, including, but not limited to, transformers, electrical panels, etc. to complete the service. This should be done first thing upon possession of space. No temporary power will be provided to Tenant spaces. Tenant Contractors are advised to bring step down transformers and panels or an appropriate generator upon the start of construction as the Landlord is not providing construction power. Tenant contractors will not have power for construction unless these arrangements have been made. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN IN TENT. EXISTING 200A WIRE AND GRD. IN 2" CONDUIT STUBBED INTO SPACE BY LL. EXISTING CONDUIT STUBBED INTO SPACE FOR TELECOMMUNICATIONS BY LL. EXISTING 200A /3P DISCONNECT WITH 200A FUSES TO REMAIN.- EXISTING METER IN EXISTING METER SOCKET TO REMAIN.-- LEASE LINE LL'S ELECTRIC RM TENANT SPACE - "H2 0' 1 -'200 r-I �M� Panel Wiring Schedule (3- Phase) Panelboard Panel Type NEMA Type "A" NQOD 1 Voltage OCPD Mounting 208Y/120 50A M.C.B. SURFACE Phase 3 Wire 4 Buss 100A Options/Notes AIC Rating 10,000 Ckt. No. Zone Load Description Brkr. Size Brkr. Opts. N.E.C. kVA Phase N.E.C. kVA Brkr. Opts. Brkr. Size Load Description Zone Ckt. No. 1 - / L SHOW WINDOW DEMAND ALLOWANCE o .45-0 A 0.360 KIT APPLIANCE 0.000 CASH WRAP 1.00 2 3 3 STOCK LTG - 3.980 0.164 B 0.180 - 0.000 SF RECEPTACLE 0.000 4 5 0.000 TRACK LTG 1.584 [6],[71 0.960 C 0.360 1.500 [8] TELEPHONE 1.875 6 7 - SF TRACK 0.000 N.E.C. DEM. KVA X 1000 0.344 A 0.000 = MINIMUM = 36.5 SPARE 208 X 1.732 8 9 SPARE 0.000 B 0.540 RECEPTACLES 10 11 SIGN LO 1.200 C 0.540 RECEPTACLES 12 13 SPARE 0.000 A 1.500 WATER HEATER 14 15 ALES LT 1.30: B 0.400 Lo CASH REGISTER 16 17 SPARE 0.100 C 0.000 SPARE 18 19 VAV -1 20/3 0.528 A 0.000 SPARE 20 21 0.528 B 0.400 Lo CASH REGISTER 22 23 0.528 C 0.000 SPACE 24 25 SPARE 0.000 A 0.000 SPARE 26 27 SPARE 0.000 B 0.000 SPARE 28 29 SPARE 0.000 C 0.000 SPARE 30 Notes ** All circuit breakers to be 20-Amp, 1-Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total E Existing Circuit to remain IG Isolated Ground Circuit 3.132 2.520 3.588 9.240 Connected Load: 25.6 NEC 2005 Demand Feeder Load: 28.2 kVA kVA kVA kVA amps amps Breaker Options: AS LO ST AUX PA GFCI HACR SF AFC! Powerlink AS Breaker Handle lock -on device Shunt Trip Type Auxiliary Contacts Handle Padlock Attachment Ground Fault Circuit Interrupter Heating, NC & Refrigeration Subfeed Arc Fault Circuit Interrupter E.C. TO VERIFY ALL EXISTING ELECTRICAL SERVICE CONDITIONS PRIOR TO BID. E.C. TO REUSE EXISTING PANELS, CKT BREAKERS AND DISC. SW. (IF IN GOOD CONDITION AND SIZED APPROPRIATELY) OR FURNISH AND INSTALL NEW. REUSE OF ANY EXISTING ELECTRICAL EQUIPMENT SHALL BE REFLECTED IN BID. LANDLORD PROVIDED 200A /3P FUSED DISCONNECT SWITCH, WITH LANDLORD PROVIDED 200A FUSES. TENANT TO RELOCATE IF REQUIRED, AND EXTEND WIRE AND CONDUIT AS NEEDED. 3 #10 THWN AND 1 #10 GRD. IN 3/4 "C. E.C. TO EXTEND EXISTING ELECTRICAL SERVICE TO NEW ELECTRICAL EQUIPMENT AS NECESSARY. ri 1 NEW WIREWAY FLOOR EXISTING 277/480V, 30, 4W, LANDLORD METERING SWITCHBOARD ELECTRIC ROOM. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. NEW PANEL "A" 120/208V. 3C, 4W 50A M.C.B. 4 #8 THWN AND 1 #10 GRD. IN 3/4" C. #8 GRD. TO BLDG. STEEL PER NEC. FLOOR NEW FLOOR MOUNTED 15 KVA TRANSFORMER 480V, 30 DELTA PRI. 120/208V, 30, 4W WYE SEC. BY TENANT E.C. POWER RISER DIAGRAM NTS ALL NEW TERMINATIONS SHALL BE 75" C RATED ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA LIGHTING (CONTINUOUS) 2.176 [1] 1.25 2.720 TRACK LIGHT DEMAND ALLOWANCE - [2] - 3.000 SHOW WINDOW DEMAND ALLOWANCE - [3] - 0.000 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 3.980 [51 - 3.980 MOTORS 0.000 [6] - 0.000 FIXED ELECTRIC SPACE HEATING 0.000 [6],[71 - 0.000 AIR CONDITIONING SYSTEM 1.584 [6],[71 - 1.584 ELECTRIC WATER HEATER 1.500 [8] 1.0 1.875 MISCELLANEOUS 0.000 - 1.0 0.000 N.E.C. DEM. KVA X 1000 9.240 FEEDER AMPERAGE AMPS 13.159 = MINIMUM = 36.5 SYS. VOLTAGE X 1.732 13.159 X 1000 208 X 1.732 ELECTRIC LOAD SUMMARY 480Y/277V SYSTEM DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.EC. DEMAND FACTOR N.EC. DEMAND kVA LIGHTING (CONTINUOUS) 2.176 [1] 1.25 2.720 TRACK LIGHT DEMAND ALLOWANCE - [2] - 3.000 SHOW WINDOW DEMAND ALLOWANCE - [31 - 0.000 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 3.980 [5] - 3.980 MOTORS 0.000 [6] - 0.000 FIXED ELECTRIC SPACE HEATING 0.000 [61.[71 - 0.000 AIR CONDITIONING SYSTEM 1.584 [6],[71 - 1.584 ELECTRIC WATER HEATER 1.500 [8] 1.0 1.875 MISCELLANEOUS 0.000 - 1.0 0.000 TOTAL N.E.C. DEM. KVA X 1000 SYS. VOLTAGE X 1.732 13.159 X 1000 9.240 TOTAL FEEDER AMPERAGE AMPS 13.159 = MINIMUM = 15.8 480 X 1.732 LOAD SUMMARY NOTES: [11 POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. [2] 150VA/2FT OF LINE VOLTAGE TRACK + SUM LOW VOLTAGE XFRMS CONNECTED LOAD [3] 200VA/LF - ACTUAL CONNECTED LOAD [4] KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 [5] 0.0 <1 OKW » 100 %, REMAINING - 50% [6] 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. [7] USE GREATER VALUE OF THESE TWO CATEGORIES [8] 125% DEMAND FACTOR FOR TANK TYPE, 100% FOR INSTANT HOT POWER RISER DIAGRAM GENERAL NOTES CODE COMPLIANCE APPROVED JUL 01 2008 City g Tukwila ' BUILDIN DMSION 1. HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO ±1O% BETWEEN PHASES: A/B B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. TENANT'S NAME AND SPACE NUMBER SHALL BE APPLIED TO DISCONNECT SWITCH AT SWITCHGEAR WITH BLACK PLASTIC LAMENT WITH WHITE LETTERS. RECEIVED JUN 2 4 2008 PERMIT CENTEFI Emphcah On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m- corporations.com Project Desert 4 Drawings ® 2001 Jarman Architecttre Orfgfnal Prototc s Desirert ® 2006 Armin Arch itecttre OPPAffil!Pb ERFJC °1 CI DT ©T JHE HEMEL DD ESOC K C M©LDD AVENUE CLEVELAND, 0 100 441115 PHONE 210.781.0121 1©07t©1 G'A M {a 2I6. 7 8100 54 JUN 1 9 2000 ILO i` T 0) W C M IS CO C L T J cD CO CC O Q cp Q CO v g 0 CO E5 1- a) a) � T EIS V0SO U E3 rttoionrimen muss POWER G 0`a C R DATE: 5/20/08 RICHARD R. JENCEN ASSOCIATES ELECTRICAL SPECIFICATIONS GENERAL CONDITIONS: A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLETE /FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENURE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND SPECIFICATIONS: A. THIS ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING DRAWINGS. SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE FLEX CONNECTIONS SHALL BE LIMITED TO 6' -0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY —IN CEILINGS ARE ACCEPTABLE.) 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT MAY BE USED AS SPECIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD & INSPECTION AGENCIES PRIOR TO INSTALLATION). ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO— GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF ROMEX OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8' -0" FOR 3/4" THRU 1 1/4" AND 1O' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. E. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CLIPS" OR EQUAL. G. FLASH AND COUNTERFLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK —TITE" FOR #6 AND LARGER. C. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM NEUTRAL — WHITE PHASE A OR L1 —BLACK PHASE B OR L2 —RED PHASE C OR L3 —BLUE GROUND —GREEN LIGHTING: 277/480 VOLT SYSTEM NEUTRAL — WHITE WITH TRACER OR GRAY PHASE A OR Li — BROWN PHASE B OR L2— ORANGE PHASE C OR L3— YELLOW GROUND—GREEN WITH TRACER A. LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE LIGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "INTERNATIONAL ENRGY CONSERVATION CODE 2001." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNI— STRUT, AND NOT SUPPORTED BY CEILING SYSTEM. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. C. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. ALL ENCLOSURES AND NON— CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON— CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN — UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL —TO —METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES: A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY ARCHITECT. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION). 1. RECEPTACLES SHALL BE 20 AMP, 3 —WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. FLOOR BOXES TO BE HUBBELL #B- 2527/29 WITH S -3925 BRASS COVER (OR EQUAL BY "STEEL CITY") AND HUBBELL 5362 RECEPTACLE (UNLESS OTHERWISE NOTED) 5. EQUAL BY ARROW —HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOUD COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230 -70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. LIGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER— HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NONFUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR UTTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON— FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL)_ C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES: A. B. C. OUTLET BOXES AND COVERS PRESSED STEEL KNOCKOUT. JUNCTION, PULL BOXES AND CODE GAUGE SIZE. SHALL BE GALVANIZED, ONE —PIECE COVERS SHALL BE GALVANIZED STEEL, INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. SERVICES: A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENURE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE LIMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACIUTIES PRIOR TO BIDDING PROJECT. C. D. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. STEP —DOWN TRANSFORMER: A. PROVIDE DRY —TYPE TRANSFORMER AS MANUFACTURED BY SQUARE "D" , HEAVY DUTY, ACME, GENERAL ELECTRIC, SIEMENS ITE OR OTHER EQUIVALENT MANUFACTURERS, OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS WITH COILS DESIGNED FOR 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS 220 DEGREE C INSULATION AND A MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TWO ABOVE AND FOUR BELOW NORMAL). SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE "KORFOUND" OR EQUAL VIBRATION— DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS. THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS. LIGHTING CONTACTOR AND TIMER SWITCHES: A. CONTACTORS FOR CONTROL OF LIGHTING AND SIGNS SHALL BE SQUARE "D", CLASS 8903, TYPE "L ", ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. B. TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IF REQUIRED /DESIRED OTHER LIGHTING. THE TIMER SHALL BE A PARAGON MODEL 7000—SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULING FORMAT. INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL UNE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBIUTY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL /TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HIL11 AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. REV1Ew i rut€ CODE COMPLIANCE APPROVED JUL 01 2008 City Of Tukwila BUILDING ILDING D SION ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE LANDLORD'S GURNEE MILLS TENANT HANDBOOK 11. ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR OR MALL OPERATIONS MANAGER AND BECOME FAMILIAR WITH THE REQUIREMENTS CONTAINED WITHIN PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REQUIREMENTS CONFLICT WITH CODES OR ORDINANCES THE STRICTEST INTERPRETATIONS SHALL APPLY. RECEIVED JUN 24 2008 PERMIT CENTER Empltash On pence M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com ProJect Design # Drawirgs ® 2001 amen Archttectire Original Prototype Design ® 2006 Jansen ,Arciltecturs a ARCH_DTIECTU 111 RETAILS oDESOC 2 350 EUCLID /WERE CLEVELAND, ©0 000 44 115 MCK o 216181.0131 IF \X0 216381.011S4 JUN 1 9 27,7; Lc) ✓ 0) — # w CO L r" J 4) 00 cc 45 t O 0 ci) 0< o O cif < to° im P NEVI'S OOHS E4 welennterom err ELEC t`�AL S �L MAYS DATE: 5/20108 COMM. X5496 _,_ JI VAV -1 A -10 VAV-1 T —STAT A -12 A-6 I L POWER PLAN 1/4 " =1' -0" ELECTRICAL SYMBOLS ALL SYMBOLS DO NOT NECESSARILY APPLY SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED 0 -e SF 2)wP 4)GF1 I 0 {{} 3 4 x ®s 0 0 El Q WIRED JUNCTION BOX RECESSED(FLOOR) DUPLEX RECEPTACLE, 20A SINGLE RECEPTACLE, 3 WIRE GRD. TYPE, 15A DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE, 20A DUPLEX RECEPTACLE, WEATHERPROOF, 20A GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 20A ISOLATED GROUND DUPLEX RECEPTACLE, 20A QUADRAPLEX WALL RECEPTACLE, 20A LIGHTING CONTACTOR TIME CLOCK (TIME SWITCH) PUSHBUTTON STATION LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER TOGGLE SWITCH -- SINGLE, 3 —WAY & 4—WAY MANUAL MOTOR STARTING SWITCH W/ PILOT LIGHT TELEPHONE OUTLET DATA OUTLET — CATEGORY 5 COMBINATION DATA /PHONE OUTLET SAFETY SWITCH COMBINATION STARTER /SAFETY SWITCH MOTOR OUTLET — 1 PHASE MOTOR OUTLET -- 3 PHASE FIRE ALARM PULL STATION FIRE ALARM VISUAL SIGNAL DEVICE FIRE ALARM STROBE/HORN SIGNAL DEVICE DUCT MTD. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS SYSTEM HEAT DETECTOR (FIXED TEMP.) ARE ALARM WATER FLOW SWITCH FIRE ALARM TAMPER SWITCH SYSTEM SMOKE DETECTOR RECESSED CEILING SPEAKER (PAGING /MUSIC /SECURITY) SEE DRAWINGS FLOOR AS REQUIRED CEILING MID. 18" U.N.O. 18" 18" 18" 18" AS REQUIRED AS REQUIRED 48" AS REQUIRED 54" 48" 48" 18" 18" 18" AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED 48" 80" 80" AS REQUIRED CEILING MID. AS REQUIRED AS REQUIRED CEILING MID. CEILING MID. NOTE: ELECTRICAL CONTRACTOR MUST VERIFY LOCAL CODES. °E" BY FIXTURE DENOTES FIXTURE I5 EXISTING. A -2 A -16 A -18 Bulletin 3 Southcenter Mali - Tenant Design Criteria To Southcenter Tenants Date: 5/16/2007 This Bulletin serves as the most up to date information regarding Electrical Design for all Tenant Improvement at the Southcenter Mali. The information below supersedes the information in the Tenant Design Criteria Manual dated March 2007. It is the responsibility of the Tenant to forward this information to the Tenant's Architect and Electrical Engineers. Electrical Design Criteria Landlord Work: 1. Change RMU's to 30A,120V,1 Phase, 3/4" Conduit [or Walker duct] 2. Change Retail Merchants, smaller than 3,000SF: 200A MC Cabling 3. Change ALL Retail, Dining Terrace and Restaurants to MC cabling, in lieu of conduit. SEPARATE PERMIT REQUIRED FOR: ErMechanical ❑ Electrical *tufting areas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. POWER PLAN CODED NOTES: ® ELECTRICAL SERVICE EQUIPMENT. SEE RISER DIAGRAM ON SHEET E -3 FOR MORE INFORMATION. ® PROVIDE TELEPHONE BACKBOARD WITH DEDICATED DUPLEX RECEPTACLE AS SPECIFIED ON SHEET E -4. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. 03 PROVIDE TELEPHONE OUTLET, CONDUIT AND (2) CAT. 3 CABLE TO TELEPHONE BACKBOARD. SIZE AS REQUIRED BY TELEPHONE EQUIPMENT SUPPLIER, 1" MINIMUM, BUSH CONDUITS ENDS. ® PROVIDE DATA OUTLET, 1" CONDUIT AND (2) CAT. 5 CABLE BACK TO OUTLET AT MANAGER'S DESK IN STOCKROOM. ONE CABLE SHOULD TERMINATE IN AN RJ45 JACK ON EACH END. ONE IN STOCK ROOM AND ONE IN CASHWRAP. SECOND CABLE I5 A BACKUP. COORDINATE WITH CPU EQUIPMENT. ® PROVIDE DEVICES AS INDICATED AND MOUNT IN MILLWORK. VERIFY LOCATIONS AND COORDINATE WITH OWNER AND MILLWORK PRIOR TO INSTALLATION. V RECEPTACLES AND COVERPLATES WITH AN "SF" DESIGNATION SHALL BE FLUSH MOUNTED IN CEILING AT STOREFRONT, PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. (NEC ART. 210 -62) K 1" CONDUITS RUN UNDER FLOOR. CHANNEL AND PATCH FLOOR AS REQUIRED. COORDINATE CHANNELING WITH LANDLORD PRIOR TO STARTING WORK. 8 ELECTRONIC CASH REGISTER POWER SYSTEM. THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSES. THE CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL DO NOT USE THE CONDUIT FOR GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES. THE CIRCUITS FOR THE ELECTRONIC CASH REGISTERS SHALL BE RUN IN SEPARATE CONDUIT. ELECTRONIC CASH REGISTER OUTLETS SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL. THIS SYSTEM IS REQUIRED BY THE TENANT. ® COORDINATE EXACT STUB —UP LOCATIONS FOR CASHWRAP WITH MILLWORK. PROVIDE 4"X4" J —BOX WITH 10 CASHWRAP FOR DATA MOU IS �4 A F F SEE CODED NOTE 5 11 1/2" EMPTY CONDUIT WITH PULL STRING FROM THERMOSTAT TO UNIT IT SERVICES. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION. 12 PROVIDE TIME SWITCH: PARAGON MODEL 7000—SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULING FORMAT, MIN. (4) N.D. 20 AMP 120/277 VOLT CONTACTS 120 VOLT COIL AND SPRING WOUND RIDE THROUGH. SWITCH SHALL CONTROL STORE FRONT SIGN LIGHTING AS INDICATED. RE —USE EXISTING WHERE APPLICABLE. VERIFY WORKING CONDITION. O. REFER TO HVAC CONNECTION SCHEDULE FOR WIRING, CONDUIT, AND CIRCUIT REQUIREMENTS. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. Oi 2 #12 AND 1 #12 GND FOR 1.5 KW TANK —TYPE WATER HEATER TO BE CIRCUITED TO PANEL A. 15 DUCT MOUNTED SMOKE DETECTOR. FURNISHED AND WIRED BY TENANT E.C. INSTALLED BY MECHANICAL CONTRACTOR. E.C. SHALL FURNISH WITH REMOTE TEST /RESET SWITCH MOUNTED ON CEILING OR WALL BELOW UNIT. FIELD VERIFY EXACT LOCATION. VERIFY EXACT MODEL AND TYPE WITH LANDLORD TO ENSURE COMPATIBILITY WITH LANDLORD'S SYSTEM. E.C. SHALL VERIFY EXACT REQUIREMENTS WITH LANDLORD FOR CONNECTION TO THE LANDLORD'S SYSTEM AND INCLUDE ALL COSTS IN HIS BID. POWER GENERAL NOTES FILE COPY Permit No. 661 Mar review approval is subject to errors and ominslons. Approval of condo:lion doh does not authorize the violation of any adopted code orb. Receipt 01 approved -r= d Copy and maims is acknowledged: City of Tukwila BUILDING DIVISION 1. REFER TO PLUMBING PLAN FOR LOCATION OF PLUMBING EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. 2. ELECTRICAL CONTRACTOR TO PROVIDE TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL CONDUITS SHALL BE CONCEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES. 5. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF RECEIVED RECEPTACLES, DATA /TELEPHONE OUTLETS AND OTHER DEVICES. MAY , 1 4 2008 PERMIT CENTER ELO8- 551 FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. Dennis T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 ARLINGTON, TX 76017 817 - 265.2415 FAX 817 -483 -7377 DTMArchitect @DTMArchitect.com Emphasis on Face M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com SEAL: DATE: MAY 0 9 2008 THE GE?ERAL CONTRACTOR AO /OR ALL 8118COf'tiR4CTORa WOG FROM THESE PLANS AND SPECIFICATIONS ARE NOT TO SCALE SUCH NFORIATION BUT TO CONTACT 11-E ARCHITECT OR 1-1I5 REPRESENTATIVE NTATIVE REGAR'I% hEASURRIENT5, iF SUCH MEASUREMNTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE PROJECT: Mks virAmin WORLD PROJECT LOCATION: VITAMIN WORLD 1119 SOUTHCENTER MALL TUKWILA, WA 98188 TOTAL AREA: 900 SP. SHEET TITLE: POWER PLAN PROJECT NO. 0813048 SCALE: AS NOTED DATE: 4/1/2008 DRAWN EY: YTS REVIEWED 13Y: LTS L S1 -IEET NO. 4 1:1;1101011;1]E. 0 NL /EM A -5 ■ ■r or r ;. • 111111111111 LIGHTING PLAN 1/4”-=v-o” LIGHT FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NO LAMPS MOUNTING VOLTS A METALUX RWWT1BX4OM1 --EB51 (2) F4OBX RECESSED 120 RECESSED WALL WASHER 4'X1', SUPPLIED BY TENANT. 6' -0' O.C. Al TBD BY OWNER TBD BY OWNER (1) F4OBX RECESSED 120 RECESSED WALL WASHER 2'X1', SUPPLIED BY TENANT. 38W BALLAST. B METALUX 2EP3GX2U6T8W33P -EB81 (2) FB032/835 RECESSED 120 9 CELL WHITE LOUVER 2'X2' FLUOR. W /ENERGY SAVING BALLAST. SUPPLIED BY TENANT. B1 METALUX 2EP3GX2U6T8W33P -EB81 (2) FB032/835 RECESSED 120 9 CELL WHITE LOUVER 21X2' FLUOR EMERG. LIGHT IN SALES AREA W /ENERGY SAVING BALLAST & BATTERY BACK -UP. SUPPLIED BY TENANT. C METALUX 2GPAS- 332 -EB81 (2) F032/835 RECESSED 120 Cl METALUX ... _. ' 2GPAS- 332 -EB81 (2) F032/835 ___._.__ _ ____ __..______W._ .__ _._..._._.__ —_ RECESSED 120 D COOPER LTG C7118 18W HEAD TRACK 120 TRACKHEAD, SUPPLIED BY TENANT. E ATLITE PNLRU - WALL /CEILING 120 EXIT SIGN LED TYPE WITH BATTERY BACK-UP, SUPPLIED BY TENANT. F NUT ❑NE QT100L (1) 100A19 RECESSED 120 EXHAUST FAN /LIGHT C ❑MB❑, SUPPLIED BY TENANT, -- ------ .- .-- .-_- .._.._... __...._...__ _____.... -- __...— ..__._ _.._...__. .___-- .___ -- G HALO L3240 (1) F4OBX COMPACT FLU❑RSCENTS RECESSED 120 TRACK LIGHTING, SUPPLIED BY TENANT, L_ LIGHTING PLAN KEY NOTES+ 0 EMERGENCY, EXIT AND NIGHT LIGHTS TO BE CIRCUITED TO A -1. HOMERUN THROUGH TIME CLOCK. SEE POWER PLAN CODED NOTE #12. (3 HOMERUN THROUGH SWITCH 'a' LOCATED IN STOCK ROOM NEAR DOOR FOR GENERAL SALES LIGHTING. ® HOMERUN THROUGH SWITCH 'b' LOCATED IN STOCK ROOM NEAR DOOR FOR SALES TRACK LIGHTING. (-5.") HOMERUN THROUGH SWITCH 'c' LOCATED IN STOCK ROOM NEAR DOOR FOR STOCKROOM LIGHTING. ® JUNCTION BOX AND DISCONNECT SWITCH FOR STOREFRONT SIGN PER NEC 600. E.C. SHALL PROVIDE ANY NECESSARY COMPONENTS. SEE ARCHITECTURAL PLANS FOR EXACT LOCATION. LIGHTING GENERAL NOTES 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. 4. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE (120/277 VOLT INPUT) WITH BATTERY BACKUP. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 6. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE USE OF THERMALLY PROTECTED LIGHTING WITH LOCAL CODES AND ORDINANCES. RECESSED LIGHT FIXTURES SHALL COMPLY WITH ARTICLES #410 -64; #410 -68 AND #410 --73 OF THE NATIONAL ELECTRICAL CODE REGARDING TEMPERATURE, CLEARANCE, CONSTRUCTION AND INSTALLATION. c:c1 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY 1 6 2008 CityOf Tukwila BUILDING DM ION RECEIVED MAY ;14 2008 PERMIT CENTER FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. Dennis T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 ARLINGTON, Tx 76017 817.265 -2415 FAX 817- 483 -7377 DTMArchitect @DTMArchitect.com Ernphania an Banco M- Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m— corporations.com I ExPIRC.5 07 / 11 /7571 SEAL: DATE: MAY 0 9 2008 THE GENERAL CONTRACTOR AND /OR ALL 5UECONTRACTORS IIIOR'JNG FROM NE51= FLANS AND SFECIPICATIONS ARE NOT TO SCALE SUCH INFORMATION IMIT to CONTACT tHE ARCHITECT OR HI5 REPRESENTATIVE REGM:4M MEASUREMENTS, F SUCH MEASUREMENTS DO NOT APPEAR CORRECT, ADD UP PROPERLY OR SCALE CORRECTLY TO THE INDICATED SIZE. PROJECT: e virRmin WORD D PROJECT LOCATION: VITAMIN WORLD 1119 SOUTNCENTER MALL TUKWILA, WA 98188 TOTAL AREA: 900 S.E. 51-IEET TITLE: LIGf -ITING FLAN PROJECT NO. 081348 SCALE: AS NOTED DATE: 4/1/2008 DRAWN SY: REVIEWED BY: SKEET NO. ELECTRICAL CONNECTION SCHEDULE UNIT VOLTAGE FLA MCA MOCP A/POLE GROUNDED AND UNGROUNDED CONDUCTORS CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT CONNECTION NOTES VAV -1 208V, 3 PHASE 4.4 5.5 20/3 (3) #12 THWN & (1) #12 GND 3/4" 30A, 3 -POLE, NONFUSED A- 19/21/23 0.360 KIT APPLIANCE 0.000 CASH WRAP 1.00 2 3 3.960 STOCK LTG - 3.980 NOTE: VERIFY EXACT OVER CURRENT PROTECTION /DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL ELECTRICAL POWER CONNECTIONS. Bulletin 13 Southcenter Mall - Tenant Design Criteria To: Southcenter Tenants Date: 11 /19/2007 This Bulletin serves as the most up to date information regarding the Temporary Power for Construction for all Tenant Improvement at the Southcenter Mall. The information attached supplements the information in the Tenant Design Criteria Manual dated March 2007. It is the responsibility of the Tenant to forward this information to the Tenant's Architects, Engineers, and Contractors. Temporary Power for Construction Each Tenant Contractor will complete their electrical installation to provide for a "Temporary to Permanent" Electrical Meter and service. The Landlord shall provide a main circuit breaker in a Landlord Electrical room and conduit and conductors (feeders) from the circuit breaker to a Landlord provided fused disconnect switch located within the Tenant space. The voltage supplied to the Tenant space will be 277/480v, unless otherwise indicated. Upon possession of the space, the Tenant shall install all electrical work necessary for a complete electrical distribution system within the premises, including, but not limited to, transformers, electrical panels, etc. to complete the service. This should be done first thing upon possession of space. No temporary power will be provided to Tenant spaces. Tenant Contractors are advised to bring step down transformers and panels or an appropriate generator upon the start of construction as the Landlord is not providing construction power. Tenant contractors will not have power for construction unless these arrangements have been made. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. EXISTING 200A WIRE AND GRD. IN 2" CONDUIT STUBBED INTO SPACE BY LL. EXISTING CONDUIT STUBBED INTO SPACE FOR TELECOMMUNICATIONS BY LL. LEASE LINE LL'S ELECTRIC RM TENANT SPACE EXISTING 200A /3P DISCONNECT WITH 200A FUSES TO REMAIN EXISTING METER IN EXISTING METER SOCKET TO REMAIN.~ Hi _ 30 NEW WIREWAY s Panel Wiring Schedule (3- Phase) Panelboard Panel Type NEMA Type "A" NQOD 1 Voltage OCPD Mounting 208Y/120 50A M.C.B. SURFACE Phase 3 Wire 4 Buss 100A Options/Notes AIC Rating 10,000 Ckt. No. Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA ** Phase N.E.C. kVA ** Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 - EXIT/EM /NL SHOW WINDOW DEMAND ALLOWANCE Lo 0.400 A 0.360 KIT APPLIANCE 0.000 CASH WRAP 1.00 2 3 3.960 STOCK LTG - 3.980 0.064 B 0.180 - 0.000 SF RECEPTACLE 0.000 4 5 0.000 SPARE 1.584 [6],[7] 0.000 C 0,360 1.500 [8] TELEPHONE 1.875 6 7 - SF TRACK 0.000 N.E.C. DEM. KVA X 1000 0.108 A 0.000 = MINIMUM = 36.9 SPARE 208 X 1.732 8 9 SF LTG 0.126 B 0.540 RECEPTACLES 10 11 SIGN Lo 1.200 C 0.540 RECEPTACLES 12 13 SPARE 0.000 A 1.500 WATER HEATER 14 15 SALES LTG 0.620 B 0.400 Lo CASH REGISTER 16 17 SPARE 0.000 C 0.000 SPARE 18 19 VAV -1 20/3 0,528 A 0.000 SPARE 20 21 0.528 B 0.400 LO CASH REGISTER 22 23 0.528 C 0.000 SPACE 24 25 SPARE 0.000 A 0.000 SPARE 26 27 SPARE 0.000 B 0.000 SPARE 28 29 SPARE 0.000 C 0.000 SPARE 30 31 0.000 A 0.000 32 33 0.000 B 0.000 34 35 0.000 C 0.000 36 37 0.000 A 0.000 38 39 0.000 B 0.000 40 41 0.000 C 0.000 42 Notes ** All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total 2.896 2.858 2.628 8.382 E Existing Circuit to remain 10 Isolated Ground Circuit Connected Load: 23.3 NEC 2005 Demand Feeder Load: 25.2 Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device kVA ST Shunt Trip Type kVA AU)( Auxiliary Contacts kVA PA Handle Padlock Attachment kVA GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter amps amps E.C. TO VERIFY ALL EXISTING ELECTRICAL SERVICE CONDITIONS PRIOR TO BID. E.C. TO REUSE EXISTING PANELS, CKT BREAKERS AND DISC. SW. (IF IN GOOD CONDITION AND SIZED APPROPRIATELY) OR FURNISH AND INSTALL NEW. REUSE OF ANY EXISTING ELECTRICAL EQUIPMENT SHALL BE REFLECTED IN BID. LANDLORD PROVIDED 200A /3P FUSED DISCONNECT SWITCH, WITH LANDLORD PROVIDED 200A FUSES. TENANT TO RELOCATE IF REQUIRED, AND EXTEND WIRE AND CONDUIT AS NEEDED. 3 #10 THWN AND 1 #10 GRD. IN 3/4 "C. E.C. TO EXTEND EXISTING ELECTRICAL SERVICE TO NEW ELECTRICAL EQUIPMENT AS NECESSARY. NEW PANEL "A" 120/208V. 30, 4W 50A M.C.B. 4 #8 THWN AND 1 #10 GRD. IN 3/4" C. #8 GRD. TO BLDG. STEEL PER NEC. FLOOR EXISTING 277/480V, 30, 4W, LANDLORD METERING SWITCHBOARD ELECTRIC ROOM. FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. FLOOR NEW FLOOR MOUNTED 15 KVA TRANSFORMER 480V, 30 DELTA PRI. 120/208V, 30, 4W WYE SEC. BY TENANT E.C. POWER RISER DIAGRAM NTS ALL NEW TERMINATIONS SHALL BE 75" C RATED ELECTRIC LOAD SUMMARY (TRANSFORMER) 208Y/120V LOADS DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA LIGHTING (CONTINUOUS) 1.318 [1] 1.25 1.648 TRACK LIGHT DEMAND ALLOWANCE - [2] - 4.200 SHOW WINDOW DEMAND ALLOWANCE - [3] - 0.000 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 3.960 [5] - 3.980 MOTORS 0.000 [6] - 0.000 FIXED ELECTRIC SPACE HEATING 0.000 [61,[7] - 0.000 AIR CONDITIONING SYSTEM 1.584 [6],[7] - 1.584 ELECTRIC WATER HEATER 1.500 [8] 1.0 1.875 MISCELLANEOUS 0.000 - 1.0 0.000 N.E.C. DEM. KVA X 1000 8.382 FEEDER AMPERAGE AMPS 13.287 = MINIMUM = 36.9 SYS. VOLTAGE X 1.732 13.287 X 1000 208 X 1.732 ELECTRIC LOAD SUMMARY 480Y/277V SYSTEM DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.G. DEMAND FACTOR N.EC, DEMAND kVA LIGHTING (CONTINUOUS) 1.318 [1] 1.25 1.648 TRACK LIGHT DEMAND ALLOWANCE - [2] - 4.200 SHOW WINDOW DEMAND ALLOWANCE - [3] - 0.000 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 3.980 [51 - 3.980 MOTORS 0.000 [6] - 0.000 FIXED ELECTRIC SPACE HEATING 0.000 [6],[71 - 0.000 AIR CONDITIONING SYSTEM 1.584 [6],[7] - 1.584 ELECTRIC WATER HEATER 1.500 [8] 1.0 1.875 MISCELLANEOUS 0.000 - 1.0 0.000 TOTAL N.E.C. DEM. KVA X 1000 8.382 TOTAL FEEDER AMPERAGE AMPS 13.287 = MINIMUM = 16.0 SYS. VOLTAGE X 1.732 13.287 X 1000 480 X 1.732 LOAD SUMMARY NOTES: [1 ] POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. [2] 150VA 2FT OF LINE VOLTAGE TRACK+ SUM LOW VOLTAGE XFRMS - CONNECTED LOAD [3] 200VA/LF - ACTUAL CONNECTED LOAD [4] KIT APPLIANCE DEMAND FACTOR PER NEC 220-20 [5] 0.0 < 10KW = 100%, REMAINING - 50% [6] 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. 171 USE GREATER VALUE OF THESE TWO CATEGORIES [8] 125% DEMAND FACTOR FOR TANK TYPE, 100% FOR INSTANT HOT 6i;Vb POWER RISER DIAGRAM GENERAL NOTES CODE NF�� COMPLIANCE NEC MAY 1 6 2008 ��YOf r�kuvila BUILDING DM ION 1. HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO ±1O% BETWEEN PHASES: A/B B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. TENANT'S NAME AND SPACE NUMBER SHALL BE APPLIED TO DISCONNECT SWITCH AT SWITCHGEAR WITH BLACK PLASTIC LAMENT WITH WHITE LETTERS. RECEIVE MAY 1 4 2008 PERMIT CENTS& Dennis T Mitchell NCARB, AIA Architect 6031 1 -20 WEST, SUITE 260 ARLINGTON, TX 76017 817. 265.2415 FAX 817483.7377 DTMArchitect@DTMArchitect.com Emphaele an Excellence M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m- corporations.com Eo'iPins 07 / 11 / 09 SEAL: DATE: MAY 0 9 2008 THE CORAL CONTRACTOR AND/OR ALL SUBCCTIiRACTOR5 tlbFd(ING PROM THESE FLANS AND 5FECIFICATION5 ARE NOT TO SCALE 5U04 INFORMATION 13U1 TO CONTACT THE ARCHITECT OR HIS REFRESMATIVE RECIAiRDMCs MEA&UREMI NT5, IF SUCH MEA5UREh'IETrr5 DO NOT APPEAR CORRECT, ADP UP PROPERLY OR SCALE CORRECTLY To 114E INDICATED SIRE PROJECT: virRmin WORLD PROJECT LOCATION: VITAMIN WORLD 1119 SOUTWCENTER MALL TUKWILA, WA 9818E3 TOTAL AREA: 900 S.E. SHEET TITLE: SCIAEIDULES 4 ROWER RISERS PROJECT NO. 0SI3048 SCALE: AS NOTED DATE: 4/1/2008 DRAWN BY: REVIEWED BY: SHEET NO. 1 =3 ELECTRICAL SPECIFICATIONS GENERAL CONDITIONS: A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLETE /FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES UST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPUCABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK I5 TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLETE AND FULLY OPERATIVE ELECTRICAL SYSTEMS. PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. DRAWINGS AND SPECIFICATIONS: A. THIS ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, STRUCTURAL, AND OTHER BUILDING DRAWINGS. SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION OR SET SCREW TYPE. B. FLEXIBLE CONDUIT SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL TYPE FLEX CONNECTIONS SHALL BE LIMITED TO 6' -0" IN LENGTH. (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY —IN CEILINGS ARE ACCEPTABLE.) 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4" FOR STANDARD CONDUIT, AND 1/2" FOR FLEX CONDUIT (1/2" STANDARD CONDUIT MAY BE USED AS SPECIFIED ABOVE, IF ACCEPTABLE WITH LANDLORD AND LOCAL CODES, ELECTRICAL CONTRACTOR SHALL FIELD COORDINATE WITH LANDLORD & INSPECTION AGENCIES PRIOR TO INSTALLATION). ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO— GALVANIZED. FITTINGS SHALL BE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY, RACO, T & B, EFCOR OR EQUAL EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEIUNGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF ROMEX OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8' -0" FOR 3/4" THRU 1 1/4" AND 10' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEIUNG SYSTEM. E. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CUPS" OR EQUAL G. FLASH AND COUNTERFLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. C. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK —TITE" FOR #6 AND LARGER. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: 120/208 VOLT SYSTEM NEUTRAL — WHITE PHASE A OR L1 —BLACK PHASE B OR L2 —RED PHASE C OR L3—BLUE GROUND —GREEN LIGHTING: 277/480 VOLT SYSTEM NEUTRAL — WHITE WITH TRACER OR GRAY PHASE A OR L1 — BROWN PHASE B OR L2— ORANGE PHASE C OR L3— YELLOW GROUND—GREEN WITH TRACER A. LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE LIGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "INTERNATIONAL ENRGY CONSERVATION CODE 2001." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNI— STRUT, AND NOT SUPPORTED BY CEIUNG SYSTEM. WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. C. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. ALL ENCLOSURES AND NON—CURRENT CARRYING METALS TO BE GROUNDED- CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON— CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN — UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL METAL —TO —METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. WIRE DEVICES: A. COLOR OF WIRING DEVICES AND COVERPLATES SHALL BE SELECTED BY ARCHITECT. (SEE PLAN NOTES FOR ADDITIONAL INFORMATION). 1. RECEPTACLES SHALL BE 20 AMP, 3 —WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. FLOOR BOXES TO BE HUBBELL 0- 2527/29 WITH S -3925 BRASS COVER (OR EQUAL BY "STEEL CITY") AND HUBBELL 5362 RECEPTACLE (UNLESS OTHERWISE NOTED) 5. EQUAL BY ARROW —HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPEWRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230 -70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE POLE BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. LIGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY SIEMENS ITE, CUTLER— HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NONFUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON— FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE 0, SIEMENS ITE, CUTLER HAMMER, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. BOXES: A. OUTLET BOXES AND COVERS PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND CODE GAUGE SIZE. SHALL BE GALVANIZED, ONE —PIECE COVERS SHALL BE GALVANIZED STEEL, C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH I5 GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. SERVICES: A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE UMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. STEP —DOWN TRANSFORMER: A. PROVIDE DRY —TYPE TRANSFORMER AS MANUFACTURED BY SQUARE "D" , HEAVY DUTY, ACME, GENERAL ELECTRIC, SIEMENS ITE OR OTHER EQUIVALENT MANUFACTURERS, OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS WITH COILS DESIGNED FOR 150 DEGREE C RISE ABOVE A 40 DEGREE C AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS 220 DEGREE C INSULATION AND A MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TWO ABOVE AND FOUR BELOW NORMAL). SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE "KORFOUND" OR EQUAL VIBRATION— DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS. THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTALLED VIBRATION ISOLATORS. LIGHTING CONTACTOR AND TIMER SWITCHES: A. CONTACTORS FOR CONTROL OF LIGHTING AND SIGNS SHALL BE SQUARE "D ", CLASS 8903, TYPE "L ", ELECTRICALLY HELD. EQUIVALENT PRODUCTS BY OTHER MANUFACTURERS ARE PERMITTED. B. TIME SWITCHES SHALL BE USED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IF REQUIRED /DESIRED OTHER UGHTING. THE TIMER SHALL BE A PARAGON MODEL 7000 — SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULING FORMAT. INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN ONES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER UNES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH UNES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL /TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SIUCATE, SIUCONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HILT! AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. E. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKEUTE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, UGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. F. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. G. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. H. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACIUTATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. RECEIVED MAY 14 2008 PERMIT CENTEF ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE LANDLORD'S GURNEE MILLS TENANT HANDBOOK 11. ALL CONTRACTORS SHALL OBTAIN A COPY FROM THE LANDLORD'S TENANT COORDINATOR OR MALL OPERATIONS MANAGER AND BECOME FAMIUAR WITH THE REQUIREMENTS CONTAINED WITHIN PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REQUIREMENTS CONFUCT WITH CODES OR ORDINANCES THE STRICTEST INTERPRETATIONS SHALL APPLY. Dennis T Mitchell NCARI3, AIA Architect 6031 1-20 WEST, SUITE 260 ARLINGTON, TX 76017 817. 265 -2415 FAX 817 -483 -7377 DTMArchitect@DTMArchitectcom Emphasis on Excellence M• Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 PHONE 614.818.2323 FAX 614.818.2337 WEB www.m — corporations.com tRnes '07 j I i / 09 SEAL: DATE: 11•ft1'1 ) e./ NOTI THE GENERAL CONTRACTOR AND /OR ALL °.AIBCANiR4CTORS WOWJ G FROM THESE PLANS AND SPECIFICATIONS ARE NOT to SCALE EiJG-I INFoRMATICN MT TO CONTACT THE ARCHITECT OR HIS REPRESENTATIVE REGARDINCx MEASLREMINtS, IF SUCH MEASUREMENTS ITS Do NOT APPEAR CORRECT, ADP UP FROFERLY OR SCALE CORRECTLY To THE INDICATED SIZE PROJECT: virAmin WORLD L PROJECT LOCATION: VITAMIN IUORLD 1119 SOUTHCENTER MALL TUKUJILA, IVA 98188 TOTAL AREA: 900 S.E. SHEET TITLE: ELECTRICAL SPECIFICATIONS PROJECT NO. 0813045 SCALE: AS NOTED DATE: 4/1/2008 DRAWN BY: REVIEWED BY: SHEET NO. 4