Loading...
HomeMy WebLinkAboutPermit EL08-0584 - SABEY DATA CENTERSABEY DATA CENTER 3355 S 120 PL ELO8-584 Parcel No.: Address: Suite No: Cit,bf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1023049069 3355 S 120 PL TUICW ELECTRICAL PERMIT Permit Number: EL08 -584 Issue Date: 07/01/2008 Permit Expires On: 12/28/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SABEY DATA CENTER 3355 S 120 PL , TUKWILA WA SABEY CORPORATION 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA LAURA RANNOW 56147AVS, SEATTLE WA VECA ELECTRIC CO INC 56147AVS, SEATTLE WA Contractor License No: VECAECI542MU Phone: Phone: 206 239 -8121 Phone: 206 860 -0231 Expiration Date: 10/31/2009 DESCRIPTION OF WORK: CONNECT OWNER FURNISHED GENERATORS AND ELECTRICAL DISTRIBUTION SWITCHBOARDS. GENERAL LIGHTING IN UPS AND GENERATOR ROOM. MECHANICAL DISTRIBUTION POWER. Value of Electrical: Type of Fire Protection: 125,000.00 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied Fees Collected: National Electrical Code Edition: $0.00 2005 Date: U'ti Ifl1 /3 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru e performan e • ork. I am authorized to sign and obtain this electrical permit. Signatu Print Name: tAUtfeVi- NIU00U- Date: !(((O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -584 Printed: 07 -01 -2008 Parcel No.: 1023049069 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3355 S 120 PL TUKW SABEY DATA CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -584 ISSUED 05/15/2008 07/01/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating . •nstruction or the performance of work. (.._Signatu IL.. . • — � Date: 7 7( /0 Print Name: doc: Cond -Elec EL08 -584 Printed: 07 -01 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://wwwci.tukwila.wa.us Electrical Permit No. evA -`7;4-1 Von -1I1 (For office use only) Project No. ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3355 South 120th PL Tenant Name: Sabey Data Center Property Owners Name: Sabey Data Center Mailing Address: 3355 South 120th P1 King Co Assessor's Tax No.: Suite Number: New Tenant: loraol -10/1 Floor: ❑ Yes E3 ..No Tukwila WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Laura Rannow Mailing Address: 5614 7th Ave S Day Telephone: 206 - 239 -8121 Seattle WA 98108 E -Mail Address: laura.rannow@veca.com City State Fax Number: 425-696-0128 Zip ELECTRICAL CONTRACTOR INFORMA &INth 120th P1 Company Name: VECA ELECTRIC Mailing Address: 5614 7TH AVE S, SEATTLE, WA 98108 Contact Person: LAURA RANNOW E -Mail Address: laura . rannow®veca . com Contractor Registration Number: VECAECI542MU City State Day Telephone: 206- 436 -5245 Fax Number: 425 - 696 -0128 Zip Expiration Date: 10/31/08 Valuation of Project (contractor's bid price): $ 1, 125, 000.00 Scope of Work (please provide detailed information): Connect owner furnished generators and electrical distribution switchboards. General lighting in UPS and Generator room. Mechanical distribution power. Will service be altered? Type of Use: Data Center Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy Seattle City Light ❑ Service Change ❑ Fire Alarm H \Apphcanons \Forms - Applications On Line \4-2007 - Electrical Permit Apphcanon doc bh ❑ Remodel ❑ Telecommunication ta Tenant improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ca ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW .ER OR ELECTRICAL CONTRACTOl. Signature`r Date: S-I( /68 Print Name: LAURA RANNOw Day Telephone: 206- 436 -5245 Mailing Address: 5614 7TH AVE S, SEATTLE, WA 98108 City State Zip IDate Application Accepted: Cci ts -09 Date Application Expires: 11 \Apphcanons \Forms- Apphcanons On Line A-2007 - Electncal Permit Appbcanon doc bh Staff Initials: j jj/ _ Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUI{W Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: EL08 -584 Status: PENDING Applied Date: 05/15/2008 Issue Date: Receipt No.: R08 -01649 Initials: User ID: Payee: JEM 1165 Payment Amount: $12,877.55 Payment Date: 05/15/2008 09:46 AM Balance: $0.00 VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 042925 12,877.55 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 10,302.05 2,575.50 Total: $12,877.55 2486 05/16 9710 TOTAL 12877.55 doc: Receipt -06 Printed: 05-15 -2008 INSPECTION RECORD Retain a copy with permit ELOgw INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: 2ioo eli ry 464 CAriSA AIWA &tyd-ze Pswio t. tics Disi Address: 335C.5•izoR• Date Called: Special Instructions: Date Wanted: '� /fsi erdn. Requester: Phone No: MApproved per applicable codes. Corrections required prior to approval. COMMENTS: eli ry 464 CAriSA AIWA &tyd-ze Pswio t. tics Disi ClAtw.5 - 5uUGork 14- 0.5 4\iieti, 0-K . / Inspector: 66Utic y El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: IZ aq o' Receipt No.: !Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit ktoFs' - e PERMIT NO. Project: 44 'c$,a +ets 1 7 Type of Inspection: —A !- l v� Address. s7 s / d'' /^! Date Called: Special Instructions: Date Wanted: // ^� 0 ( ,10 / p.m. Requester: Phone No: .proved per applicable codes. LJ Corrections required prior to approval. COMMENTS: (/1 l"., -- c A /L- /! V 01/64 Moll / IYA (.. , cff i c/_ - 5 Inspryr .lG 061". 744 69 (Date: /to 7% ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: •a ..nr w +iA+•w _ -. ,,,r, . Al, - - INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION AZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: _ S / ^ v . /2 ,, v Date Called: Special Instructions: Date Wanted: /lib of rgs rr� Requester: Phone No: 014 -- iii // d. fc f74 "5 proved per applicable codes. Corrections required prior to approval. Ilnsp, U!! L COMMENTS: pic) d/- C _.E./1.-f , ; t )f/ • IM GUAM y — 2:i.-bltadi .c-gvm f�[- // - i /l] Aic F 014 -- iii // d. fc f74 "5 f'G 2 --..7 i 6 /i JG/l Arr,54.4/./e4 N [Date:,,,,i,, /U r ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPEfCTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit ittoq-s9y PERMIT NO. • 1- (206)431 -3670 Project s L y M cis Type of Inspection- -20 j .-c' to/P, ci s 4 / /f/ / /f // ,fVN' A r t. /U /_l/ Date Called: 3/ dk f!- or /U/A) 47. GLtivex's /U!) 7D FAY /oe & e C)oliJki / T ii9,4,A f'j Special Instructions: 7) 110) ; Ait 1 f2/ii(fj 67%i.S //v f liV:S Date Wanted: 9, in �. a r p.m. Requester: Phone No: Approved per applicable codes. orrections required prior to approval. COMMENTS: - R/` %,c ,Ci)s- �. P7/ 6� 7 f,si _ l .-c' to/P, ci s 4 / /f/ / /f // ,fVN' pi/: _off /4J 6. -) Ci eartT //)( 7m/ t s 4"41 of %s ■%7 r-o44/i`-4 c `` i a/:- joT TU /441- 64)1 -/4/ 3/ dk f!- or /U/A) 47. GLtivex's /U!) 7D FAY /oe & e C)oliJki / T ii9,4,A f'j ltt)l P/ • /k 1' dF C WAi 7) 110) ; Ait 1 f2/ii(fj 67%i.S //v f liV:S OR -; ' /ivX 4iP. — CC Inspe p;L L 1/1/171/ p Date//1 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: WILY 4/47X Type of Inspectiori. 2.0 Address X' Date Called: Special Instructions: Date Wanted: .' e Requester: Phone No: 'loved per applicable codes. Corrections required prior to approval. MMENTS: 0/4 - / #t c i,JA y Inspe�„ � / �.4d ,q/4 c/7 I e ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lid 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: -We / )v? Cfiv 4 Type of Inspection: 76V 2 Ad ress: �+ Date Called: Special Instructions: Date Wanted: / 7/ 22. a.m .m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: (91k- g -K-0c2 02741/ 777 swi7H cf,� Insp -;/r14 i ..)!./ 1444/,11101 ^ ", n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Gll�..s�se al.,f sRak4l0�. 1rtr ---- �im"s- .sd;.sx.. '6s INSPECTION NO. INSPECTION RECORD Retain a copy with permit kiC` _ 4- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro jest;, 67f eN V lt? � i 'Type of Inspection: �J 70637 Address:. Date Called: /11)A Z/- cl Special Instructions: Date Wanted: "1 /`1 . .. p.m. Requester: Phone No: proved per applicable codes. ElCorrections required prior to approval. EOMMENTS: % /11)A Z/- cl 17 — 6,/1 /4 -'12 ,%?s /"c.,•v/1-/.r Inspe 67-/-x4m6ll Date: 7/..?4, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: FILE COPY PERMIT CENTER _ _ _ VECA Electric Sweo H DP52A ROOM: SDC 52 MAIN ELEC ROOM I i LOAD DISTRIBUTION FROM: UNIT SUBSTATION TA =52 RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0.0 0.0 369.0 0.0 UPS 52-Al PRIMARY 1200 3 369 444 - UPS 52-Al STATIC BYPASS 1200 3 - - AMP: 4000 MBP -52 -A1 MAINT BYPASS 1200 3 - - VOLTS: 277 0.0 0.0 369.0 0.0 UPS 52 -C1 PRIMARY 1200 3 369 - 444 480 UPS 52 -C1 STATIC BYPASS 1200 3 = PHASE: 3 MBP -52 -C1 MAINT BYPASS 1200 3 - WIRE: 3 369.0 UPS 52 -B1 PRIMARY (FUTURE) 1200 3 369 444 BUS: CU UPS 52 -B1 STATIC BYPASS (FUTURE) -_ 1200 3 - - A.I.C.: 65K MBP -52 -B1 MAINT BYPASS (FUTURE) 1200 3 - - M.L.Q.: 276.0 UPS 52 -D1 PRIMARY (FUTURE) 800_ 3 276 332 MAIN CB: YES UPS 52 -D1 STATIC BYPASS (FUTURE) 800 3 - - FUSE: MBP -52 -D1 MAINT BYPASS (FUTURE)- 800 3 - - FLUSH: 0.0 0.0 608.2 0.0 DP -52 -A MECH 1600 3 608 732 SURF: YES 0.0 8.0 0.0 0.0 52 -H4A LIGHTING VIA 30 KVA 50 3 8 10 16.5 0.0 5.7 0.0 52 -L4A RECPT VIA 30 KVA 50 3 22 27 TVSS 100 3 IG GND: 74.0 89.0 293.0 COMMON AREA LOADS (FUTURE) 1200 3 456 548 200% N: = FD THRU: - DBL LUG: = TOP: REVIEWED REVIEWED FOR - = BTM: YES CODE COMPLIANCE ` 1- = PANEL T.C.L. NFPA 70 �L NEC X11 LOAD (kVA) - RCPT 91 JUN 3 U 1UU8 - - LTG 97 - EQP 2,290 69 ,�' 1 HEAT - F CRY 0 kwila - - BUI (fit IVISION - - - TOTAL 2,477 D +L+�++ lti� 1 �V - - FEEDER T.C.L. - - LOAD (kVA) . _ - - RCPT 91 - - LTG 97 - EQP 2,290 = HEAT - - - _- - TOTAL 2,477 - = FEEDER DEMAND - - kVA 2,461 TOTAL 2,477 _ 2,980 AMPS 2,961 91 97 2,290 - MFG: 1 S Q D _ t - NOTE: — SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL Feeder T.C.L. is printed here horizontally TO GENERATOR POWER: I - _ - -- -- RECEIVED toallowablock'paste- link'to the - QTY OF 'momI � 'Load Distribution' columns of a sub- !1 p� feed panel or switchboard. Project: SDC = 525/13/08 MAY- j -j- M Y 1 5 ZOO& - -- , 05/14/08 FILE COPY PERMIT CENTER VECA Electric SWBD MBP -52 -A1 ROOM: SDC 52 MAIN ELEC ROOM _ -- - 1_ _ _ LOAD DISTRIBUTION FROM: HDP -52A _ RCPT LTG EQP HEAT DESCRIPTION _ _ AMP P 'kVA AMPS ' 123.0 STS -A1 -1 _ 400 3 123 148 123.0 STS -A1 -2 (FUTURE) __ 400 3 123 148 AMP: 1200 123.0 STS -A1 -3 400 3 123 148 VOLTS: 277 STS -B 400 3 - - 480 STS -C 400 3 - - PHASE: 3 STS -D 400 __ 3 - _ WIRE: 3 - BUS: CU ,- - A.I.C.: 65K - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES = IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. _ LOAD (kVA) - RCPT - - - LTG - EQP 369 _ = HEAT = _ = TOTAL 369 - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 369 - - HEAT - - - TOTAL 369 - = FEEDER DEMAND _ - kVA 369 TOTAL 369 444 AMPS 444 - - 369 - MFG: SQ D here horizontally to CB: SQ D NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH KIRK KEY TRANSFER FROM NORMAL _ Feeder T.C.L. is printed the TO BYPASS MODE. to allow a block 'paste-link' i 'Load Distribution' columns of a sub- feed panel or switchboard. 1 1 Project 1 SDC -52 5/13/08 j 05/14/08 VECA Electric Viet) MBP -52 -C1 } I ROOM: SDC 52 MAIN ELEC ROOM - LOAD DISTRIBUTION FROM: HDP -52A - -- „ i RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 123.0 STS -C1 -1 (FUTURE) _ 400 3 _ 123 148 123.0 STS -C1 -2 (FUTURE) - 400 3 123 148 AMP: 1200 123.0 STS -C1 -3 400 3 123 148 VOLTS: 277 STS -A 400 3 = 480 STS -B 400 3 = PHASE: 3 STS =D 400 3 = - WIRE: 3 - - BUS: CU A.I.C.: 65K - M.L.O.: - - MAIN CB: YES _ - FUSE: - - FLUSH: - SURF: YES - IG GND: - - 200% N: _ - FD THRU: - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. = LOAD - (kVA) - RCPT - - LTG - - EQP 369 _ - HEAT - - - TOTAL 369 - - FEEDER T.C.L. = LOAD (kVA) - RCPT - = - LTG - - - EQP 369 _ - HEAT - - - TOTAL 369 - - FEEDER DEMAND _ - kVA 369 TOTAL 369 444 AMPS 444 - 369 - MFG: SQ D CB: SQ D _ NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH KIRK KEY TRANSFER FROM NORMAL Feeder T.C.L. is printed here horizontally TO BYPASS MODE. - ' to allow a block 'paste -link' to the 'Load Distribution' columns of a sub- —f— ` feed panel or switchboard. I Project: SDC -52 5/13/08 _ 05/14/08 VECA Electric SWBD DP -52 -A I ROOM: 3RD FLOOR NW FROM: HDP -52A LOAD DISTRIBUTION RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 64.0 _ AHU -52 -A1 125 3 64 77 64.0 AHU-52-A2 125 3 64 77 AMP: 1600 8.0 RF -52A 20 - 3 8 10 VOLTS: 277 218.0 CH -52A1 350 3 218 262 480 218.0 CH -52A1 350 3 218 ` 262 PHASE: _ 3 CH -52A2 (FUTURE) 350 3 - - WIRE: 3 CH -52A2 (FUTURE) 350 3 - - BUS: CU 24.0 CHP -52 -A 70 3 24 29 A.I.C.: 65K 12.2 AHU-52 -A3_ _ 40 3 12 15 M.L.O.: YES 3 = - MAIN CB: 3 = - FUSE: 3 - - FLUSH: 3 - - SURF: YES 3 = - 3 - 3 - - IG GND: 3 - - 200% N: FD THRU: = DBL LUG: - TOP: - - BTM: YES PANEL T.C.L. _- LOAD (kVA) - - RCPT - - - - - - -- - - - LTG - - = EQP 608 = HEAT - - - TOTAL 608 - - FEEDER T.C.L. LOAD (kVA) = = RCPT - - - LTG - = EQP 608 - - HEAT - - - TOTAL 608 - - FEEDER DEMAND - - kVA 608 TOTAL 608 732 AMPS 732 - 608 = MFG: SQ D CB: NOTE: _ Feeds T.C.L. is printed here horizontally t- to allow a block 'paste-link' to the 'Load Distribution' columns of a sub - feed panel or switchboard. Project: SDC -52 5/13/08 05/14/08 I I I . VECA Electric SWBD H DP52B ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION TB -52 RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 369.0 UPS 52 -A2 PRIMARY 1200 3 369 444 UPS 52 -A2 STATIC BYPASS 1200 3 - AMP: 4000 MBP -52 -A2 MAINT BYPASS 1200 3 - - VOLTS: 277 369.0 UPS 52 -C2 PRIMARY 1200 3 369 444 480 UPS 52 -C2 STATIC BYPASS 1200 3 - - PHASE: 3 MBP -52 -C2 MAINT BYPASS 1200 3 - - WIRE: 3 369.0 UPS 52 -B2 PRIMARY (FUTURE) 1200 3 369 444 BUS: CU UPS 52 -B2 STATIC BYPASS (FUTURE) _ 1200 3 - = A.I.C.: _65K _ MBP -52 -B2 MAINT BYPASS (FUTURE) 1200 3 - - M.L.O.: 276.0 UPS 52 -D2 PRIMARY (FUTURE) 800 3 276 332 MAIN CB: YES UPS 52 -D2 STATIC BYPASS (FUTURE) 800 3 - - FUSE: MBP -52 -D2 MAINT BYPASS (FUTURE) _ 800 3 - - FLUSH: 0.0 0.0 608.2 0.0 DP -52 -B MECH 1600 3 608 732 SURF: YES 52 -H4B LIGHTING VIA 30 KVA (FUTURE) 50 3 - 52 -L4B RECPT VIA 30 KVA (FUTURE) 50 3 - - - TVSS 100 3 - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - TOP: - BTM: YES = PANEL T.C•L. - LOAD (kVA) - - RCPT - - - LTG - - = EQP 1,991 _ - HEAT - _ - TOTAL 1,991 _ = FEEDER T.C.L. _ - _ LOAD _ _ (kVA) - RCPT - - - LTG - - - EQP 1,991 - - HEAT - - - TOTAL 1,991 _ - FEEDER DEMAND - - kVA 1,991 TOTAL 1,991 2,395 AMPS 2,395 1,991 - MFG: iSQ D CB _ ` t NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC T RANS FER FROM NORMAL, Feeder T.C.L. is printed here horizontally TO GENERATOR POWER_ to allow a block 'paste -link' to the 'Load Distribution' columns Of a sub - t feed panel or switchboard. Project:1SDC — -52 5/13/08 - 1 05/14/08 VECA Electric _ SWSD MBP - 52 -B2 I • ROOM: SDC 52 MAIN ELEC ROOM _ LOAD DISTRIBUTION FROM: HDP -52B - -- RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS , 123.0 STS -A1 -1 400 3 123 148 123.0 - STS -A1 -2 (FUTURE) 400 3 123 _148 AMP: 1200 123.0 _ STS- A1 -3 400 3 123 148 VOLTS: 277 STS -B 400 3 - 480 STS -C _ _ 400 3 - - PHASE: 3 STS -D 400 3 - WIRE: 3 - - BUS: CU - A -I.C.: 65K - - M.L.O.: - MAIN CB: YES FUSE: - - FLUSH: = - SURF: YES - - - - - - - - - - IG GND: - - 200% N: - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - PANEL T.C.L. -- LOAD (kVA) - RCPT - - - LTG - - - EQP 369 - HEAT - - - TOTAL 369 FEEDER T.C.L. _ - _ - LOAD (kVA) _ - RCPT - - _ - LTG - - - EQP 369 - - HEAT - - - TOTAL 369 - FEEDER DEMAND - - kVA 369 TOTAL 369 444 AMPS 444 - - 369 - MFG: SQ D CB: _ SQ D TRANSFER NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH KIRK KEY FROM NORMAL Feeds T.C.L. is printed here horizontally TO BYPASS MODE. - - - 1 to allow a block 'paste -link' to the - I 'Load Distribution' columns of a sub- feed panel or switchboard. r 1 Project: - - - -- i 1 SDC-52 5/13/08 - � 05/14/08 VECA Electric SWBD MBP -52 -D2 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52B RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 123.0 STS -D1 -1 400 3 123 148 - 123.0 - - -- - -- -- - STS -D1 -2 (FUTURE) - -- 400 3 123 -__ 148 AMP: 1200 123.0 STS -D1 -3 400 3 123 148_ VOLTS: 277 STS -B 400 3 = - 480 STS -C 400 3 - - PHASE: 3 STS -A 400 3 - - WIRE: 3 - - BUS: CU - A.I.C.: 65K M.L.O.: = MAIN C8; YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: 200% N: - FD THRU: - - DBL LUG: - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - RCPT - - - LTG - - - EQP _369 - - HEAT - = TOTAL 369 = FEEDER T.C.L. = LOAD (kVA) - - RCPT - - - LTG - - - EQP 369 _ - - HEAT - - TOTAL 369 _ = FEEDER DEMAND - kVA 369 TOTAL 369 444 AMPS 444 - 369 MFG: SQ D CB: SQ D here horizontally NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS 'WITH KIRK KEY TRANSFER FROM NORMAL Feeder T.C.L. is printed TO BYPASS MODE: to allow a block 'paste -link' to the columns of a sub - switchboard. _ 'Load Distribution' feed panel or SDC 52 5/13/08 - - 7 T F T Project - 05/14/08 VECA Electric swBD DP -52 -B - — ROOM: 3RD FLOOR NW L FROM: HDP -52A LOAD DISTRIBUTION RCPT LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 128.0 AHU -52 -B1 225 3 128 154 _ - AMP: 1600 8.0 _ RF -52B 20 3 - -_ 8 10 VOLTS: 277 218.0 CH-52B1 350 3 218 262 480 218.0 _ CH -5281 - 350 3 218 262 PHASE: 3 CH-52B2 (FUTURE) -_ 350 3 - - WIRE: 3 CH -52B2 (FUTURE) 350 3 - - BUS: CU 24.0 CHP -52 -B _ _ _ 70 3 24 29 A.I.C.: 65K 12.2 AHU -52 -82 40 3 12 15 M.L.O.: YES _ 3 - MAIN CB: 3 = = FUSE: 3 = = FLUSH: 3 - - SURF: YES 3 - - 3 - - 3 - - IG GND: 3 - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES _ - PANEL T.C.L. LOAD (kVA) - - RCPT - = LTG - _ = EQP 608 - - HEAT - TOTAL 608 - FEEDER T.C.L. - LOAD (kVA) - - RCPT - LTG - - EQP 608 _ - HEAT - - - TOTAL 608 - FEEDER DEMAND _ - kVA 608 TOTAL 608 732 AMPS 732 - - 608 - MFG: SO D — CB: r == NOTE: Feede T.C.L. is printed here horizontally to allow a block 'paste-link' to the 'Load Distribution' columns of a sub - feed panel or switchboard. Project: SDC-52 5/13/08 - — t 05/14/08 I VECA Electric PANEL 52 -H4AI ROOM: PROVIDENCE OFFICE FEED -THRU: LOADS FROM: HDP -52A RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.0 1 PROVIDENCE DATA CENTER LIGHTS A 20 1 2.0 7.2 2.0 3 PROVIDENCE DATA CENTER LIGHTS B 20 1 2.0 - - 7.2 AMP: 100 2.0 5 PROVIDENCE OFFICE LIGHTS _ C _20 1 _ 2.0 7.2 VOLTS: 277 2.0 7 PROVIDENCE OFFICE LIGHTS A 20 1 2.0 7.2 480 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 __ 0.0 A.I.C.: 18K 17 C 20 1 _ 0.0 0.0 MLO: 19 A 20 1 0.0 0.0 MCB' YES 21 B 20 1 _ _ 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: - _YES_ 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND: 33 _ B 20 1 - 0.0 0.0 200% N: 1 35 C 20 1 0.0 0.0 FD THRU: 37 A 20 1 0.0 0.0 DBL LUG: 39 B 20 1 0.0 _ 0.0 TOP: 41 C 20 1 0.0 0.0 BTM: _YES 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 _ _ - 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 8.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 - - _ 0.0 - _0.0 HEAT 0.0 14 A 30 3 0.0 0:0 ______ 16 B 0.0 0.0 TOTAL _ 8.0 18 C " 0.0 0.0 . 20 A 30 3 0.0 0.0 FEEDER T.C.L. r. 22 B " 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 8.0 28 B ° 0.0 0.0 EQP 0.0 30 C " II 0.0 _ 0.0 HEAT 0.0 32 A 0.0 0.0r 34 B 0.0 0.0 TOTAL 8.0 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B " 0.0 0.0 kVA 10.0 42 C 20 1 0.0 0.0 AMPS _12.0 - A 0.0 0.0 - B ° - 0.0 0.0 - C " 0.0 0.0 0.0 8.0 0.0 0.0 KVA/AMPS: 4.0 14.4 2.0 7.2 2.0 7.2 - Mfg/Type: - 0.0 4.0 0.0 0.0 A CB Type: - _ 0.0 2.0 0.0 0.0 B Remarks: _ LL 0.0 2.0 0.0 0.0 C ! VECA Electric PANEL: 52-L4A ROOM: PROVIDENCE FEED -THRU: I LOADS FROM: 52 -TLA RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.1 1 DATA CENTER RECEPTACLES A 20 1 1.1 9.2 1.1 3 DATA CENTER RECEPTACLES B 20 1 1.1 9.2 AMP: 100 1.1 5 DATA CENTER RECEPTACLES C 20 1 1.1 9.2 VOLTS: 120 1.1 _ 7 PROVIDENCE BREAK RECEPTACLES A 20_ 1 1.1 9.2 208 1.1 9 PROVIDENCE BREAK RECEPTACLES B 20 1 1.1 9.2 PH: 3 1.1 11 PROVIDENCE BREAK RECEPTACLES C 20 1 1.1 9.2 WIRE: 4 1.0 13 COPIER A 20 1 1.0 8.3 BUS: AL 1.1 15 CUBES WEST RECEPTACLES B 20 1 1.1 9.2 A.I.C.: 18K 1.1 17 CUBES WEST RECEPTACLES C 20 1 1.1 92 MLO: YES 1.1 19 LARGE CONFERENCE RM RECEPTACLE A 20 1 1.1 9.2 MCB: 1.1 21 CUBES EAST RECEPTACLES B 20 1 1.1 9.2 3R: 1.1 23 STORAGE RECEPTACLES C 20 1 1.1 9.2 FLUSH: 1.1 25 BUILD ROOM RECEPTACLES A 20 1 1.1 9.2 SURF: YES 1.1 27 BUILD ROOM RECEPTACLES B 20 1 1.1 9.2 1.1 29 BUILD ROOM RECEPTACLES C 20 1 1.1 9.2 1.1 31 BUILD ROOM RECEPTACLES A 20 1 1.1 9.2 IG GRND 33 HVAC CONVENIENCE OUTLET B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG: 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 0.5 2 N.O.C. POWER A 20 1 0.5 4.2 PANEL T.C.L. 0.5 4 N.O.C. POWER B 20 1 0.5 4.2 LOAD (kVA) 0.5 6 N.O.C. POWER C 20 1 0.5 4.2 RCPT 16.5 0.5 8 N.O.C. POWER A 20 1 0.5 4.2 LTG 0.0 0.5 10 N.O.C. POWER B 20 1 _ 0.5 4.2 EQP 5.7 0.5 12 N.O.C. POWER C 20 1 0.5 4.2 HEAT 0.0 0.5 14 N.O.C. POWER - A__20 1 0.5 4.2 0.6 16 HEAT TRACE B 0.6 5.0 TOTAL 22.2 0.6 18 HEAT TRACE C 0.6 5.0 . 20 A 0.0 0.0 FEEDER T.C.L. f 22 - - B 0.0 0.0 LOAD (kVA) 24 - _ C 0.0 0.0 RCPT 16.5 26 A 0.0 0.0 LTG 0.0 28 B -- 0.0 0.0 EQP- 5.7 30 C 0.0 0.0 HEAT 0.0 32 _ - A 0.0 0.0 34 B 0.0 0.0 TOTAL 22.2 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 - kVA 19.0 42 C 0.0 0.0 AMPS 52.6 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 16.5 0.0 5.7 0.0 KVA/AMPS: 8.0 66.7 7.1 59.2 7.1 59.2 Mfg/Type: 5.5 0.0 2.5 0.0 A CB Type: 5.5 0.0 1.6 0.0 B Remarks: - 5.5 0.0 1.6 0.0 C IT VECA Electric PANEL: 52 -H4B (FUTURE) t ROOM: FUTURE FEED -THRU: LOADS FROM: HDP -52B A B C RCPT LTG EOP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 277 7 A _ 20 1 0.0 0.0 - _ 480 9 B 20 1 0.0 0.0 P11: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 - A 20 1 - 0.0 0.0 - - IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 - 1 0.0 0.0 FD THRL NO 37 - A 20 1 0.0 0.0 - - _ DBL LUG. 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 - A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 - 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 _ - - A 20 1 0.0 0.0 - LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B - ' 0.0 0:0 TOTAL 0.0 18 C 0.0 0.0 c 20 -- A 30 3 0.0 0.0 _ FEEDER T.C.L. r, 22 B 0.0 0.0 LOAD (kVA) 24 C • • 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 - -- LTG 0.0 28 B • " 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 _ - - A 0.0 0.0 _ 34 B 0.0 0.0 TOTAL 0.0 36 C _ 0.0 _0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B " ' 0.0 0.0 kVA 0.0 42 _- C 20 1 -_ 0.0 _ 0.0 AMPS 0.0 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 0.0 0.0 0.0 KVA/AMPS: 0.0 0.0 0.0 0.0 0.0 0.0 Mfg/Type: - - 0.0 0.0 0.0 0.0 A CB Type: - 0.0 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 0.0 C • VECA Electric PANEL 52 -L4B (FUTURE) i ROOM: FUTURE FEED =THRU: ____ LOADS FROM: _ 52 -TLB A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA [AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I:C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 _ B 20 1 _ 0.0 _ 0.0 29 _ _ C _ 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: FD THRU NO 35 C 20 1 _ 0.0 0.0 37 _ A 20 1 0.0 0.0 OBL LUG. 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A _20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 16 B 0.0 0.0 TOTAL 0.0 18 C • 0.0 0.0 c 20 _ A 30 3 0.0 _0.0 FEEDER T.C.L. fE 22 B _ " 0.0 0.0 LOAD (kVA) 24 C • " 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C " 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 0.0 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 0.0 42 C 20 1 0.0 0.0 AMPS 0.0 - A 0.0 0.0 - B ° 0.0 0.0 - C 0.0 0.0 0.0 0.0 0.0 0.0 KVA/AMPS: 0:0 0.0 0.0 0.0 0.0 0.0 Mfg/Type: 0.0 0.0 0.0 0.0 A CB Type: 0.0 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 0.0 C _ 1 HERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: E1_08 -584 DATE: 05 -15 -08 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: f1f Ut iq if3 tilling Division Public Works n Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-20-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Depart moms determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Plecise Route REVIEWER'S INITIALS: Structural Review Required nNo further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-1 7-08 Approved 1 Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Dig umentshciuting slip duc 2 17::I! Look Up a Contractor, Electlan or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License VECAECI542MU Licensee Name VECA ELECTRIC CO INC Licensee Type ELECTRICAL CONTRACTOR UBI 601190731 Ind. Ins. Account Id AGENT Business Type CORPORATION Address 1 5614 7TH AVE S Address 2 PO BOX 80467 City SEATTLE County KING State WA Zip 98108 Phone 2064365200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 7/31/1946 Expiration Date 10/31/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License CONTIK *965D6 Master Electrician Information License CONTIK *965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS 01/01/1980 ALLEN, RON AGENT 01/01/1980 • Bond Information 1 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= VECAECI542MU 07/01/2008 52B2 DP-52B 52A3 DP52A HPH12-12 HPL4-22 HPH12-12 HPH12-12 (f) 0 0 HPH12.-1 F8 Es. 1 [-I , . , , L1 ' HPH12-12 _yr ;'t . ••_. . . , - - • • - • __• 7 1.5HP 480/3/3A 2.10 ! •I I 1 I ! •I ; • 1 'I I ! ; cr) (f) (r) (f) (./) 0 (1) 2 w vBP HPH12-12_ d 8 U-) 0 0 . ,.. HPH.1.2-12 1- z, ! ..._.; '. ,; , 0 ,..o. 1. - 2; - -- 0 0 0 " 01 0 0 0 t l_i_ _ tr) , in in il-) ,.. I i _ii < : , , ; o 1 1 0 o _ 1 I .. . DIST DI.ST DIST ,- , „ - --- ---4-•• • - i DIST IVBP d0 A m (F8B) HPH12-12 v BP 02 (f) CL. •... d8 .A HPH12-12 HPH12-12 DIST DIST DIST LC) 03 03 BP H P L4 - 22 HPH12-12 1 • • • 1 ; • (f) 0 03 VBP d0AI 02 HPH12'-12 -HPH12f2 HPL4-22 '3 BAIT CHGR 1; CHGR HPL4- 10 HPL4- 22 .• DIST 0 If) DIST - • •-•-•• HPH12-12 (7) 0 0 _LJ _ _ 0 (1:P HPL4- 22 1--0---1-0 1 (F8) HPH12-10 B ljql TR PL42 HPH12-10 DAY TANK PWP & CTRLS HPL4-12 2 \`‘E--- 2 ...-- (F8) HPH12-10 I HPH12-10 11' R F0_,....÷.._0 1 , , / , s , \ \ , , , , , V' '-',.- ...(' ..1,/ \ ,/ I--.A .. , /, /, , -2--1'14-ixF--- ---, Gy_../ . HPH12-10 HPH12-10 • J—H-40 PH"' 1.5HP 4 HVS- 4 H VS- 4A, FRONT HPH12-10 0■11—C.)--1 ( ' F8B HPH12-10 HPL24 1010 1 • FUTURE UNIT SUBSTATION ; I • 1 : i . FRONT I HPH12-10 9' 3000 KVA 3000 KVA HPH12-10 1111.'0-•■11-0 1 HPH12.7-10: ' 1—C)-1-0 FUTURE UNIT SUBSTATION B -t4' A P L4 52Bp . / DAY TANK PUMP & CTRLS HPL4-14 / HPH12- VI( EF-4 1.5HP 480/3/3A . . HPH12-10 (F8) HPH12-10 IL01—C) 1 10-10 tr „ 11; 11111j ; 11__ •„' HPH12-10 (F8) HPH12-10 HPL4-24 HPH12-10 (8B) HPH12-10 - 1 I /„X H VS --AC HVS-4 FIPH2'.10_, FRONT 3000 KVA 3000 KVA HPH12-10 1 FUTURE UNIT SUBSTATION HPH12-1-6 , • HPH12-10 RHI12-10: !H PH1 2 1 ,:+1 PH124;10X: ‘.-/I I _H_o_H____0 1 ,„, • • • „ • • • .". • 1--0—f°11-0-■1 - FRONT FUTURE UNIT SUBSTATION I I 1 1 I , . dr • C) HEAT" TRACE 16,18 • • / • • 1. 1! I; • 1 • 4. 111 ! 1 ti i L _ \ , r1! REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUN 30 2008 City Of T kwila BUILDING DIVISION FE Lt; COPY Permit No. Plar review approval is subject to errors and omfions. pro of-construction document-dos 11O-authorize the violation of any adopted code or ordinance. Receipt of approved Flold Copy nations is acknoutedged; 13 Date: City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER oi 4. 84 Da F SEATAC :61.4.'ARATE PERMIT REQUIRED FOR: IVIachanical D Electrical lumbing Gas Piping City of Tukwila , • r -tc,+t/ 1 H VS- 4 H VS- 4D 3000 KVA 3000 KVA )L1 FRONI T 37 L , \ HPH12-10 / 8) HPH12-10 HPH12-10 • 61, -0-1-0 1 .'ift0---4-0-1 1-0---1-0 L HPI-112-10 / HPH12-10 40' /16 "=1' (F8) HPH12-10 1010 1 HPH12-10 1-7-0'111"1"---0■4 REVISIONS No changes shall be made to thp scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan subinitIal and may include additional plan review fees. HPL4- 24 HPL4- 24 ___ Co SABEY ARCHITECTURE CONSULTANTS • • _ • , • • -. ' • - • , • '• ' ." .• . . ••••••',;., - ••••••;,, - • . . , • r- ' • . • • VECA ELEC TR IC CONSULTANT: Veca Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436-5200 Fx (206) 763-0505 www.veca.com PERMIT SET REVIEW ELECTRICAL DD SET REVISIONS 5/14/2008 3/20/2008 11/14/2007 ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. SABEY DATA CENTER CENTRAL PLANT 52-01 BUILD OUT # Hterg0 E east DRAWING TITLE: PROGRESS DATE: FILE: PLOT: RC.FIVFD CITY OF TUKWILA PROJECT NUMBER: MAY 1 5 2008 DRAWN BY: piPRPArr CENTER CHECKED BY: APPROVED BY: DRAWING NUMBER: 1ST FLOOR MECHANICAL E2.1 1 ;% I 1 'I — -- 1 i `. i I. it i \. ?.� �'7 r .. AJ.wp « � n - YNv h" - ." P 3 +vA3 �_l c .21 M � 4?i a1 X F � L iYv6 —L% ;. E a .' , �nms k w:WX CP% i gnamm.-milmslm mamma K FZSi Y :WA s. ry u�� 1 I I 1 1 • 1 - — j I /, ' I 1 1 / rlvv:..• .:' n. :. .' >s.'., fl:. °T .n'r+t a, •. .tvcmr 'aay ,cv„ ;um• 4't^K!H`l, a ::T! � !>1CC ?Y' _ £ . ,, ? .iIMlrr xcp , M'3Y ..',p„+o!' A1...4' ,": .. :lrx.,.yim ci ^iY!` ,'S' •'T•ar.' �` w,.' . �+" *'. ?4P.tix '.. C W 2"'4'1`.. v5y.. � .rrr+ ?y [.$f;. , � � t. ._e;k+f� ;r"3"a> , k.� ., r y,.,,, , � � � ,fix . R;r, .o . � � , A � mi, - � r,& fi'.:- x<;z,�,.i;�, ;�pv �ffi' ,a ,:aa!,,, y� t....r -s... rx t?Fx�s te,`* .�?X��, S£ . � e .�E^,�3 .>rrfu. y r eau.ax�!.r_aaa � u*..,_......0 1 r.a^a,�: e.a� �?.......r�,.�.. ro..,.a..�.# 'tom.,. �:.,�.,t vY lw�u5 �,,.�'� u..r..fu..�i X5.5'1 6lYau: "�iKfa lln.w.twtl., kiGid�y:4d1 rAuw: r_.h%: u,x..4�'Ir's�$ $ma..- >�.,wY). il. �LU: SY4Y ,rL 1tasc�aiaLx.C2 3.tuvw•u � SsYL�cSaw st+is3l.. I �! 1 1 '•.. 1 r R°&i vn WM X � _ LNE g ^ � � Y te } �- #"4 - � v �� � E " . �tT; � >. VN „Y2 t n m mgram r�O !SEMEN F or $ . T ?a�. t_ W r . ^ � �NV d :fi ax x � � RYYFM ��t<� HE °z maa m Ee m ` Eh 2 : . VZ Y- ZwF". SABEY ARCHITECTURE :` ''i'ws3"'�P' t �Ft:+r�1t�'z.`�vS'�'.w�1."�`�' =a r .715wr TM m 7A7m "w*t, ;i�t �m'"p r. � nar ' a . : ft `^ y y. ......•;`SS ,. i.;u ' �^, %ssF'u� t` .}`:. 's. �r t.s P)�: Y ktt.:u -^?:; /» Gv"r_d LY 'rF;r{ i I r�'• i& 2t�Y: 3��':. �: itw:' �' fYs+ s.', F` sr�z�d. Is `',''''al���uwey�:. dv-". ��n, �t�ut�• m' tr..;.: w1k` CONSULTANTS • : "a -Hnw I- 52, ti FK•,1b2 1•1H e, 112,2E554 VECA E L E C T R I C S ^o- h1Y1K••WA A.LH 2', HE72E2 CONSULTANT: Veca Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436 -5200 Fx (206) 763 - 0505. www.veca.com MWTMEIWAnx laadzflogalgaz PERMIT SET 5/14/2008 REVIEW • 3/20/2008 ELECTRICAL DD SET 11/14/2007 REVISIONS ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. SABEY DATA CENTER CENTRAL PLANT 52 -01 BUILD OUT 11 ntergymeast mwmwhmgmnr et ;, ; ; r. '., - 1 , I1 1 Ei Y I _ W .'„ ,.. <. ST, 1r sr e.0 n ., „ 'Y, .. 2 MELT r q�.n.Y'�, 1 ,v 'ar . 512.1 .. ,- .s ram: . ".. .f•!'^ -".. s„rn. 2F?t. t -!.. .r.;:S?. ...... .. .. re .. ... r, tn°"r :i, c°"t. .. .. _n9 A I 1 ! I i 1 1 I I 1 ' a I �a1 ■ I0 1 I 1 11 I {. ^"'F: '. r+f ��. ._!:�- t� .__r. r .o-.. x... �n ,_ rJa ..� �:.ny?w, :. ,x _ lia_�; -SS:r .! �', ,.. , , -, [�a;t� t .� , �'� €d�,�k� � L'��,d. �.._,�._,.1 �a:•.,�wSS �.v.:Ts'"r L`.v�T+,d I w is I. i I! I / ' I j i. i jf i j I. 1 I ,i 1 / . «. ,r. ' a.• rvnry s - "r:S. �. FI 7c.: n - .y -x,1 rfp.,r 1,2 t.. x: E _.,,,0 'Y-, -v , ....:al .. e...r 4 , .rt TV'. r,-,p .n Si Y'. :e :. '. �. M1m'!5 :gxr, .0 r ... n H%'C. •. uny{R: 35! N !4Y r.p 4K a W. e,op..a .. ..0 ., ... 1 ,.. li. M, . _. i' : . ,. me^.,.. J. 4.. _'�a. ^9"t- ,.. "wm•!v �. .., a. H n 7 5s.. ,r3 .. ,rm ',l s .ry * "1'A�° � ..w%, _. Ex.., . .. v .,. S.. .. .. J. r _ ..� .. , c„ - fi:.....,.. - :'erf,'. , , ."T� _.. . � : .... . £f"' .. � ... t''" .. ,' � :. � `i°` t"'S _ "S 1 :..i -Y' °! '�v 4 .. � , , _ ,N � 1 . i .,.^5. .1 "'S!. ( `rcfir �. _- .,- ?_ _ _ 9 ":n'r'{' Rrv°, , rte^«' !^ mamma! �?5..'$.. �".+•'�'... _, .?."S �i,r'^ ...*.,. �,. ,. ?ii ,.. r`BI.,.,. ... ,_r. l;?.. K� a., ,.. � .. .�.... .;s - .. .. 1". ;.-7 _'a',. _. +. � we+ A.,;''.. ."r�.ta« 'Y°i .,#,..ns 4z >"�^. _,�„ !~•%`. F_ .. fi', .,*+`'� :�.: a- �°i',` -'..a c,'t:.. ,a-� P`. ,s Y., �', S'„_ ,%t, . -".X .�i`"?",.. +�.. ,,_.�..a... .u, y �. i� n., � u. �. F..,t �..» �., rte... ... „n.,.�..a.,:a. a..,_.w.., �� -.G�. ,i... �. E„._. `_, i � ._ ., - e' ..a.... r� >r r ''� ..,.. , �, _r.,..,.__ >�. �.w,.��3.� �„ �. .�YZ.._r 1,,.,`.�,s�,� rw �� ..r.�,.,al;,.r..,., . �.:.�w�t �.....>,1 � . �..R., .,......�,:r. <' .,._u.. �s � �. P x•' - - ��" __._ .rW,u>s:�'.,� u:�al_.::w:: ��:��.�::.. ,._...tt.: .r,.::.s,�.:,..,.. �,�r.r, ks..� ��.,��z ..rr_,�,W.�.�,. ��.::�..� j v1 j 1 w ;I � I , , ., , „., .. . ,... ., I 1 11 5 8 , , , , ,. , , , • I .ter. „ • , . „ . , . , 1 DRAWING TITLE: PROGRESS DATE: FILE: PLOT: PROJECT NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: - -�- i I 1 i j i 1 '1 , I ! - / j - i _ DRAWING NUMBER: ROOF MECHANICAL E2.4 SILBEY ARCHITECTURE HPH12 -12 HPH12 -12 HPL4 -22 HPH12 -12 -A CONSULTANTS HPH12 -1 HPH12 -12 HPH12 -12 CHILLER ROOM HPH12 -12 WWI/ AVANIA1 HPL4 -22 HPH12 -1 HPH12 -1 T HPH12 -12 HPH12 -1 HPH12 -12 HPH12 -12 HPH12 -12 HPH12 -12 (F88) O TO EL \, HPH12 -12 HPH12 -12 HPH12 -12 HPL4 -22 369 11 O0 2 10 HPH12 -10 (F8) H•H12 -10 HPL4 -22 HPH12 -10 1 c CF88> HPH12 -10 HPL4 -24 1-0-1-0 1 0 to 10A HPH12- VECA TO ■ LEVATOR E L E C T R DAY TANK PUMP & CTRLS HPL4 -12 HVS -4A 3000 KVA [0 0 a, -1 0 0 0 HPH12 -1 1.3IIP EF -2 /3/3A HPH12 -10 HPH12 -10 HPH12 -10 FRONT HPH12 -10 HPH12 -10 HPH12 -10 CONSULTANT: Veca Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com FRONT DAY TANK PUMP & CTRLS HPL4 -14 HVS -4B 3000 KVA HPH12 -1 EF -4 1.5HP 4 0/3/3A HPH12 -10 4-24 HPH12 -10 HP 4 -24 HPH12 -10 FUTURE UNIT SUBSTATION HVS -4C FRONT 3000 KVA HPH12 -10 FS HPH12 -10 HPH12 -10 I- --0- -1 —O 1. 1 0 1 0 1 O --P"'"0o �� ,v ' ■ r;�r, , HPH12 -10 1-0 1 0 1 CF-8) HPH12 -10 FRONT • / FUTURE UNIT SUBSTATION HVS -4D 3000 KVA 369_ HPH12 -10 HPH12 -10 F88 HPH12 -10 HPH12 -10 O C1O7B) 1- 0 1 0 1 P-- 0--1 -0 1 HIPH12- 0 HPL4 -24 HPL4 -24 - REVIEWE.E i_. CODE CQMPLIAN NEPA70 -NEC JUN 3 0 2008 City Of Tukwila BUTI nYNr fTtIT T�,� PERMIT SET 5/14/2008 REVIEW 3/20/2008 ELECTRICAL DD SET 11/14/2007 REVISIONS ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. SABEY DATA CENTER CENTRAL PLANT 52 -01 BUILD OUT llntergGdmeast DRAWING TITLE: PROGRESS DATE: FILE: P LOT: PROJECT NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: RECEIVED CITY OF TUKWILA MAY 15 2008 PERMIT CENTER DRAWING NUMBER: 1ST FLOOR LIGHTING & POWER NORTH TO SITE POWER DISTRIBUTI ❑N (2) 6 "C, 3 #350KCM, 1 #2/0 GROUND 1 #2/0 NEUTRAL O 3 —LA O 1200. MRCT 1200A M1 52 -1 K • 27 ,<V SWITC AM NC £MAR G PF MICROPROCESSOR BASED RELAY AND METERING 27KV, 3PH, 4W, 1200A BUS -AR — v SG-2 600:5 MRCT E (TYP) n SPACE FOR 1200A FUTURE BREAKER TO SYSTEM 6 52 -4 C TO SYSTEM 5, SHEET NO. E5.5 PRI v AT 1200A 52 -5 50/51 3 /■. • K . 1. 600A, 27KV 110KV BIL HVS -4A IKI !4000A• 0 GFR TA -52 3000 KVA AA 80 °C 26.4/ 15.3KV- 480/277V 0-1r ARY BJS 52A DIST. SWBD °HDP -52A' 4000A BUS 480V- 30-3W -65 KAIC 1200AT 0 1600AT 6 50AT O 50AT o)3P .)3P •)3P •)3P C600-3) 0 4000AT (1000,D • K • K • • 500 AS N,❑, 52 -3 \ o 0 6 "C — 3 SINGLE CABLE #350KCMIL, 35KV & it 2/0 GROUND, 1 #2 /0 NEUTRAL IKI AM • TO SITE POWER DISTRIBUTI ❑N 0 3 ILA \ OT =S: (2) 6 "C, 3 #350KCM, 1 #2 /0 GROUND 1 #2/0 NEUTRAL • NC 27KV, 3PH, 4W, 12004 BUS 1200. MRCT K M2 1200A 52 -2 B S O O 111W •111, AS 0 600:5 MRCT (TYP). 1200A 52 -6 4 4 MEI 1 ■t 600A, 27KV 110KV BIL HVS -4B 3C KI i 40004•\ 0 GFR TB -52 3000 KVA AA 80 °C 26.4/ 15.3KV- 480/277V PROVIDE ALARM ONLY (000) 1200A. 52 -7 3 i SPACE FOR FUTURE BREAKER. TO SYSTEM 6 u 6 "C — 3 — 1/C #350KCMIL, 35KV, 6 1# 2/0 GROUND 1 #2 /0 NEUTRAL 2500 KW 3125 KVA GENERATOR 52 -A 14000A AT .._, PM F AUTOMATIC TRANSFER CONTROL MODULE 40003 4000AT _L TAP O PORTABLE BOX FLOR AD BANK 0 52 -THA 30KVA 480V TO r -v -,480/277 I� III PANEL 52 -H4A 480/3 100A MLO DP -52 -A 1600A 480V 30 -4W )1300AT P 12003 111-0-1- 52 -TLA 30KVA 480V TO 208/120V ALT UPS CE Al -1 200AT 1200AT )1200AT 625KVA /, 562KW PRIMARY UPS MODULE 52 -Al 1200AT • • STATIC SWITCH 12003 MBP -52 -A1 MAINT. BYPASS PANEL . 1200A, 480V° 30 -3W. NC 1200AT I© 1200AT ) NO ° I3 400 1400 1400 1400 1400 14001 0 o) 0) o) o) o) STS J: ;APC POD!,APC PDU' 125KW ALT UPS CE Al -3 STS i APC - PDU,.,APC PDU'• 125KW 125KW 1200AT) 12003 II�°_ 1200AT) 1200AT) 12003 (12003 625KVA/ 562KW PRIMARY UPS MODULE 52 -C1 )1200AT STATIC SWITCH MBP -52 -C1 MAINT. BYPASS • NC PANEL ) 1200AT 1200AT ) 1200A, 480V° NO ° 30 -3W I3 I3 400 1400 1400 1400 1400 0 00 ALT SOURCE UPS C1 -3 STS 2003 APC PEW' 'APC PDUV, !APC PDU' • 125KW 125KW 125KW 1200AT°) 1200AT°) 1200AT) TYP.12 800AT 0) 800AT 800AT 0) 350AT 0 350AT 350AT 350AT �)125AT 0)70AT °)20AT °)SPARE 3P 3P • 3P • 3P • 3P 292MCA 292MCA 292MCA 292MCA 1 -75HP 2.5HP 7.5HP • 40AT 3P 15HP • SPARE 3P • F R 125AT ()SPARE 3P •3P Aglib ege „Ps PR v ARY B S 52B DIST. SWBD "HDP -52B" 4000A BUS 480V- 30 -3W -65 KAIC 0)10000AT 1.50AT AT •)50 504 (504) 4000AT 11 ■ TO SYSTEM 5, SHEET NO. E5.5 (FUTURE) AT PM PROVIDE ALARM ONLY 3 O 4000A \1 GFR 2500 KW 3125 KVA GENERATOR 52 -B AUTOMATIC TRANSFER CONTROL MODULE 4000AT _L TAP BOX FOR PORTABLE LOAD BANK 1)300AT � � )1200AT )1200AT • cao 4c) .- TYP(6) o- IiI o o 52 -TLB 30KVA 480V TO 208/120V \ 11 PANEL 52 -L4B 208/3 100A MCB 52 -TH8 30KVA w .'480V TO m480/277 Iii PANEL 52 -H4B 480/3 100A MCB DP -52 —B 1600A 480V 30 -4W ALT UPS SOURCE 81 -1 12003 625KVA/ 562KW PRIMARY UPS MODULE 52 -81 • STATIC SWITCH 1200AT 12003 MBP -52 -B MAINT. BYPASS PANEL 1200A, 4801 30 -3W • NC 1200AT 1200AT) NO • 400 1400 ) STS /APC PDU'. .APC PDU1 125KW 125KW 1400 0) 1200AT 1400 1400 400; o) o) o) ALT UPS CE B1 -3 STS I I 1 APC PDU; +APC PDU• w T • TYP4 UPS. 11 b 1200A°T) 1200AT) 1200AT) 1111H°-J CID 625KVA/ 562KW PRIMARY UPS MODULE 52 -D1 MBP -52 -D MAINT. BYPASS PANEL 1200A, 480V 30 -3W STATIC SWITCH )1200AT 12003 • NC 1200AT 1200AT ) NO 13 I4 1400 1400 1400 1400 1400 400 I O) a) °) °) a) 0) .i ALT SOURCE UPS 01 -3 STS I APC POLL ,APC PDU: 'iAPC PDU1 125KW 1-25K 125KW 1200AT0) 1200AT0) .12004 T) 800AT O) 800AT O) 800AT O) 350AT 350AT 350AT 3P 3P 3P 292MCA 292MCA 292MCA 350AT °)125AT °)70AT 3P q 3P • 3P Ito 292MCA 1 -75HP 2.5HP • 20AT ) SPARE • 3P 3P 7.5HP • 40AT °)SPARE )SPARE )SPARE • 3P 3P 3P 3P • 15HP • F= =D -R SC-IDLE 3 -PHASE 4 WIRE + GROUND SYMBOL FEEDER SIZE - CONDUIT & WIRE SIZE + GROUND 504 1 "C — 4 #6 & 1 #10G 604 1 1/4"C - 4 #4 & 1 #10G 4 704 1 1/4"c - 4 #4 & 1#8G 3/4 "0 - 3 #6 & 1#10G 1004 1 1/2"C — 4 #1 & 1 #8G -504 2 "C - 4 #1/0 & 1 #6G 2504 3 "C - 4 #250KCMIL & 1 #4G 8004 (2 SETS) 3 "C 3 #500KCMIL & 1 #1/0 NEUT. & 1 #1/0 GROUND 30004 (8 SETS) 4 "C 4 #500KCMIL Sc 1#400KCMIL G PER SET -Y \OT -S: UPS ROTATION SHALL BE ABC CW STS TO HVE (3) 225A OUTPUT BREA<ERS S: \Project Managers \Group Eaton \Terry McCabe \ SABEY \TM89007 - SDC52 Central Plant \ Drawings \Electrical Drawings \Permit •Set 5.14.08 \05 14 08 Permit Set,dwg 5/14/2008 3.38 PM F - =D -R SC- =I,L- 3- PHASE 3 WIRE + GROUND SYMBOL FEEDER SIZE - CONDUIT & WIRE SIZE + GROUND 203 1/2"C — 3 #12 & 1#120 303 3/4 "C — 3 #10 & 1#10G 4 3/4 "C — 3 #8 & 1#10G 3/4 "0 - 3 #6 & 1#10G (503) 703 1"C — 3 #4 & 1#8G 0-00-3) 2 "C - 3 #1 & 1 #8G 1503 2 "C - 3 #1/0 & 1#6G 2003 2 "C - 3 #4/0 & 1#6G 2503 2 -1/2 "C - 3 #250KCMIL & 1 #4G �0000 (2 SETS) 2-1/2"C - 3 #250KCMIL & 1#2G 8003 (2 SETS) 3 "C - 3 #500KCMIL & 1#1/0 PER SET 12003 (3 SETS) 3-1/2"C - 3 #600KCMIL & 1#3/0 PER SET .600.- (4 SETS) 3 -1 /2 "C - 3 #600KCMIL & 1#4/0G PER SET ..-000---D (5 SETS) 3-1/2"C - 3 #600KCMIL & 1 #250KCMIL PER SET 25003 (7 SETS) 3 "C 3 #500KCMIL & 1#350 KCMIL G PER SET 30003 (8 SETS) 3 "C 3 #500KCMIL & 1 #40OKCMIL G PER SET 40003 (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET REVIEWED DFOR CODE COMPLIANCE NFPA 70 °- NEC JUN 3 2008 Ci ty Of Tukwila L_L$IQ N tLO& 569 NORTH RECEIVED CITY OF TUKWILA MAY 15 2008 PERMIT CENTER 8 12 1 /8 " =1' 20 SABEY ARCHITECTURE CONSULTANTS CONSULTANT: Veca Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com IELR1i1T -Rl t- PERMIT SET REVIEW ELECTRICAL DD SET REVISIONS 5//E4/ 3/20/2008 11/14/2007 fitUR ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. SABEY DATA CENTER CENTRAL PLANT 52 -01 BUILD OUT 11 nterg ate east DRAWING TITLE: PROGRESS DATE: FILE: PLOT: PROJECT NUMBER: DRAWN BY: CHECKED BY: APPROVED BY: DRAWING NUMBER: ONE LINE RISER PHASE 5 SDC- 52- 01 E5.4