Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0601 - WESTFIELD SOUTHCENER MALL - TENANT IMPROVEMENT
WESTFIELD TENANT IMPROVEMENT 2800 SOUTHCENTER MALL ELO8-60 1 CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -601 Issue Date: 06/16/2008 Permit Expires On: 12/13/2008 Tenant: Name: WESTFIELD TENANT IMPROVEMENT Address: 2800 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: LITO PANIDA Phone: 206 - 461 -6000 Address: 900 4TH AVE SUITE 700 , SEATTLE WA Contractor: Name: SEA TAC ELECTRIC INC Phone: Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Expiration Date: 12/16/2009 DESCRIPTION OF WORK: NEW ELECTRICAL CONDUIT STUBOUTS FOR FUTURE KIOSK TENANTS & NEW COMMON LIGHTING CONTROL TO NEW LIGHTS Value of Electrical: $10,000.00 Fees Collected: $307.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature:1 ' ft.. \ ? I hereby certify that I have read and governing this work will be complie Date: Ucl' ltul a ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. //LO/4 Date: Print Name: ' etA Z Pt This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -601 Printed: 06 -16 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW WESTFIELD TENANT IMPROVEMENT Permit Number: Status: Applied Date: Issue Date: EL08 -601 ISSUED 05/16/2008 06/16/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature G lI Print Name: Date: (p //co /0- «-( doc: Cond -Elec EL08 -601 Printed: 06-16 -2008 • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. G L0 $- (Q 1 Fos- Ii-1 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION [[�� King Co Assessor's Tax No.: Site Address:` &2J'J 1 , Suite Number: Tenant Name\ h 'D TAT" N1 'T (M Pt P6 -11"1 I New Tenant: ❑ Yes ❑ ..No Property Owners Name: ► H Mailing Address: /l &e/ ( . i /w(17/LL gaz z 2 6 ' ) ) L % N f c 49f L a 5 A . " 6 6 2 - 6 - 9�a2 City State / Zip (p � O'Xo —oar 0 Floor: CONTACT PERSON - Who do we contact when your permit is ready to. be issued Name: U 11) T. &I'J I Oft Day Telephone: • 4(0,' -000Z Mailing Address: t t)t) fbitiPTP PtV1✓ 5 (1-1-7 706 -j -r us WA-. gp,i(o<f yy�� City State Zip � E -Mail Address: t 72/117 0 € �i'[/g..6//tiW:-) • CDC Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State Valuation of Project (contractor's bid price): $ b WI O Scope of Work (please provide detailed information): NLtk' t LAZT (P0i ext 1 r GI (7?` PLA t• i rt • V-4 os (L: 1v NL eoviel imel , LiCo 1k1'G0 PTO lei Will service be altered? ❑ Yes rA, No Adding more than 50 amps? ❑ Yes 4 No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H:tApphcations\Fonns- Applications On Line4-2007 - Electrical Permit Application doc bh ysb.or Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems . .$55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator).. .... $75.00 ❑ Manufactured/mobile home service.. ... . ..... $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature;, R OR ELECTRICAL CONTRACTOR: Print Name: //Z 7 zi,sL iJ!" Mailing Address: Ind Date: Day Telephone: City State Zip Date Application Accepted: r _ 0 } r( Date Application Expires: Staff Initials: H %ApplicaponslForrns-Applications On Lne■4•2007 • Electrical PermLI Appircaton, doe bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -601 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/16/2008 Applicant: WESTFIELD TENANT IMPROVEMENT Issue Date: Receipt No.: R08 -02136 Initials: JEM User ID: 1165 Payment Amount: $246.00 Payment Date: 06/16/2008 01:50 PM Balance: $0.00 Payee: SEA -TAC ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8821 246.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 246.00 Total: $246.00 3662 06/16 9711 TOTAL 246.00 doc: Receiot -06 Printed: 06 -16 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -601 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/16/2008 Applicant: WESTFIELD TENANT IMPROVEMENT Issue Date: Receipt No.: R08 -01690 Initials: WER User ID: 1655 Payment Amount: $61.50 Payment Date: 05/16/2008 12:23 PM Balance: $246.00 Payee: BNBUILDERS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 33911 61.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 61.50 Total: $61.50 doc: Receiot -06 Printed: 05-16 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ,.p/^1 CITY OF TUKWILA BUILDING DIVISION P. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 (Log Project: Flat) �t ` Type of Inspection: Zcoo U Address: Z 0D Pi Date Called: Special Instructions: Date Wanted: /Z3 am(/ p. Requester: Phone No: roved per applicable codes. EJ Corrections required prior to approval. COMMENTS: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -601 DATE: 05 -16 -08 PROJECT NAME: WESTFIELD TENANT IMPROVEMENT SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Ivislo n Fire Prevention Public Works ❑ Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-20-08 Complete Comments: Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06 -17 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electri or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SEATAEI077RW Licensee Name SEA TAC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601510212 Ind. lns. Account Id PRESIDENT Business Type CORPORATION Address 1 7056 S 220TH ST Address 2 City KENT County KING State WA Zip 98032 Phone 2538725553 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/16/1993 Expiration Date 12/16/2009 Suspend Date Separation Date Parent Company Previous License SEATAEC131QC Next License Associated License HARGRT *974CD Master Electrician Information License HARGRT *974CD Name HARGREAVES, TOM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SEATAEI077RW 06/16/2008 ELECTRICAL SITE PLAN SCALE: in = 50' —O" ELECTRICAL SPECIFICATIONS: GENERAL Visit site and make allowances in bid for field conditions. CODES AND PERMITS: All work shall be in strict accordance with applicable codes including the National Electrical Code and International Building Code. Execute work in accordance with local, state, federal, and other attending rules and regulations. The work shall be subject to the inspections of their departments. Contractor shall obtain all required permits. The work shall be performed in the best of trade practices. RACEWAYS: Raceways shall be approved for use and location. Dry locations — EMT COUPLINGS AND CONNECTORS: EMT — Compression type JUNCTION AND PULL BOXES: Steel NEMA 1, with covers. Size per NEC. RE: Copper only with THHN /THWN type insulation. No aluminum conductors allowed. UL listed lugs and connectors. NEC approved color coding. GROUNDING: In strict accordance with the NEC. Provide equipment grounding conductor in all raceways. SUPPORTS AND HANGERS: Supports and hangers must be UL listed and approved by local inspec- tors. Surface mounted conduit shall be supported with 2 —hole straps. ANCHORS: Hollow Masonry Solid Masonry — Metal — Wood — — toggle bolt expansion bolt. machine screws, bolts, welding. wood screws. LIGHT FIXTURES; Provide new light fixtures as noted complete with lamps, ballast, etc. DRAWINGS AND MEASUREMENTS: Contract drawings for electrical work are in part diagrammatic, intended to convey the scope of work and indicate general arrangement of equipment, conduits, and approximate sizes and locations of equipment and outlets. Electrical trades shall follow these drawings in laying out their work, consult general construction drawings to familiarize themselves with all conditions affecting their work, and shall verify spaces in which their work will be installed. Coordinate work with other trades as job conditions reasonably require. SUBSTITUTIONS: All substitutions shall be submitted for review by the Architect /Engineer ten (10) days prior to bid. GENERAL NOTES 1. DRAWINGS INDICATE GENERAL DESIGN INTENT AND PLACEMENT OF EQUIPMENT. INFORMATION SHOWN IS DIAGRAMMATIC AND DOES NOT NECESSARILY SHOW EVERY REQUIRED ACCESSORY, EXTENSION OR MOUNTING OPTION. PROVIDE EQUIPMENT COMPLETE WITH ALL NECESSARY ACCESSORIES AND HARDWARE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. PROVIDE COMPLETE AND OPERATING SYSTEMS MEETING THE DESIGN INTENT. 2. DO NOT SCALE DRAWINGS. COORDINATE ELECTRICAL WORK WITH THE WORK OF OTHER TRADES. LOCATIONS OF DEVICES AND EQUIPMENT SHALL SUIT SITE CONDITIONS. 4. VERIFY THE EXACT HEIGHT AND LOCATIONS OF DEVICES MOUNTED IN CASEWORK WITH CASEWORK DRAWINGS, AS WELL AS LOCATIONS AND ALL ELECTRICAL REQUIREMENTS OF DEVICES MOUNTED ABOVE COUNTERS PRIOR TO ROUGH -IN. 5. PROVIDE A CONTINUOUS GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS, RACEWAYS, FEEDERS AND BRANCH CIRCUITS WHETHER INDICATED OR NOT SIZED IN ACCORDANCE WITH THE NEC, PROVIDE A SEPARATE CONTINUOUS GREEN WITH YELLOW TRACER ISOLATED GROUND CONDUCTOR, WHERE INDICATED, SIZED IN ACCORDANCE WITH THE NEC. 6. CONDUCTOR HASH MARKS, FOR BRANCH CIRCUITS, ARE PROVIDED FOR EASE OF ESTIMATION AND ARE DIAGRAMMATIC ONLY. THE CONTRACTOR I5 RESPONSIBLE FOR VERIFYING AND PROVIDING REQUIRED WIRECOUNT AND SIZING CONDUIT ACCORDINGLY. THE OWNER SHALL NOT BE LIABLE FOR ANY COST INCREASES DUE TO WIRECOUNT CHANGES. 7. ALL SYSTEMS CABLES ROUTED EXPOSED ABOVE SUSPENDED CEILINGS AND BELOW RAISED ACCESS FLOORS SHALL BE PLENUM RATED. 8. ALL PENETRATIONS OF FIRE RATED FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UNDERWRITER LABORATORIES LISTINGS FOR THROUGH PENETRATION FIRE STOP SYSTEMS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS TO THE ARCHITECT/ENGINEER WHICH SHOW COMPLETE CONFORMANCE TO THE U.L LISTING. THE DETAILS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES DEFINED. THESE SHOP DRAWING DETAILS SHALL BE AVAILABLE ON SITE, FOR REVIEW BY ENFORCING AUTHORITY INSPECTORS. 9. IN EXISTING PANEL HJA AND EXISTING 20A /1P CIRCUIT BREAKER PRESENTLY MARKED AS 'SPARE' IS BEING USED FOR THIS PROJECT. FIELD VERIFY THE AVAILABILITY OF THIS BREAKER AND PROVIDE A NEW 20A /1P BREAKER IN AND EXISTING SPACE IN THE PANEL AS REQUIRED. THE EXISTING PANEL IS A GE #AJ142995 SERIES, PROVIDE 'TEF' OF 'TFJ' TYPE BREAKERS. 10. ADJACENT TO EXISTING PANEL HJA I5 A LIGHTING CONTROL ENCLOSURE WITH AN AVAILABLE SPACE (SLOT #3) IN AND EXISTING 3 -POLE LIGHTING CONTACTOR. FIELD VERIFY THE FUNCTION AND OPERATION OF THIS SPACE PRIOR TO MAKING AND CONNECTIONS TO IS. IF CONTACTOR IS FAULTY IN ANY WAY, PROVIDE NEW 3 -POLE LIGHTING CONTACTOR (SQUARE D .G40 OR EQUAL) AND A NEW ASTRONOMICAL TIME CLOCK (TORX#DZS100A OR EQUAL). FIELD SYNCHRONIZE NEW TIME CLOCK WITH EXISTING LIGHTING TIMECLOCK /CONTROLS AS CLOSE AS PRACTICAL SUCH THAT NEW COVE UGHTS OPERATE SIMILARLY TO EXISTING TIME CLOCK CONTROLLED COVE LIGHTS. ELECTRICAL SYMBOLS POWER CIRCUIT HOME RUN ---0 CONDUIT TURNING UP 0 CONDUIT TURNING DOHA) CONDUIT WITH CAP —11- CONDUIT HAZARDOUS LOCATION SEAL —. CONDUIT CONCEALED IN CEILING OR WALLS, POWER �1 CONDUIT CONCEALED UNDER FLOOR OR UNDER GROUND WIRING IDENTIFICATION. SHORT HASH MARKS INDICATE QUANTITY OF PHASE CONDUCTORS, LONG HASH MARK INDICATES NEUTRAL, REVERSE SHORT HASH MARK INDICATES ISOLATED GROUND, AND " S " INDICATES CONTINUATION. A CONTINUOUS GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR TO BE PROVIDED IN ALL FEEDERS AND BRANCH CIRCUITS SIZED IN ACCORDANCE WITH THE NEC. 0 OR JUNCTION BOX SIZED PER 2005 NEC DUPLEX RECEPTACLE LIGHTING 1--o- -I FLUORESCENT STRIP LIGHT DEMOLITION j/%DEMOLITION HATCH - EQUIPMENT TO BE REMOVED CONNECTION DOT ONELINE UTILITY TRANSFORMER 0 METER MAIN SWITCHBOARD ELECTRICAL GROUND SWITCHBOARD MAIN OR FEEDER BREAKER --C"-- BRANCH CIRCUIT BREAKER +� ® FUSED SWITCH *- �I1 --®- FUSED SWITCH /STARTER PAN [T uL PANEL TRANSFORMER TRANSFORMER JUNCTION BOX MOTOR COMBINATION STARTER/DISCONECT J FUSED DISCONECT T INDEX OF DRAWINGS E0.1 ELECTRICAL LEGEND, NOTES & 511E E1.0 ELECTRICAL DEMOLITION PLAN & UGHT1NG PLAN ELEVATION E1.1 KIOSKS ELECTRICAL PLAN E2.0 ELECTRICAL ONE -LINE & PANEL SCHEDULE LEGEND NOTES SEPARATE PERMIT REQUIRED FOR: itrlifethanical Q Electrical Plumbing ►►►���jjj Gas Piping BUILD NG DIVISION REVIEWED FOR CODE COMPLIANCE NF A 70 " NEC MAY 2 0 no �y Of Tu la WONG DNi ON 8.. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE .OPY Permit No. plar review approval is subject to errors and omissions. Approval of construction demote does not authorize the violation of any adopted code or ordinance. Refit 0 approved Field Copy and cancans is admowled3d By ..� Date:, l City of TUkwita BUILDING DIVISION ELOS (.001 RECEIVED MAY 16 2008 -ENMIT CENTER z 0 AiaJ Ea) > c7) w O 1.- Ooo, Z .co 0 rim CI) Z itau 121ECT3 C W .0 7; .1 43 C;:'S 0 (DC ctof E 0 .c: 0 Liu Sao LLI c5 w 73- 07129 -05 05 -09 -2008 KEY PLAN WORK IN THIS AREA NORDSTROM awe 0 1 Ir Ir fi r.. p !ii II D 0 o 0 o c I _.L tliI I n Tom* li r " ■ • IIIIIfI'1 . I�III I I:I'11 D � ■��w ''um a A� chitecture ©2008, DLR Group inc., a Washington corporate \LL RIGHTS R7 SERVED. EXISTING PRETZEL TIME EXISTING TENANT •Za ►a —I . •a.� - FIELD VERIFY EXACT LOCATION WB5300 i RETAIN EXISTING EMPTY 2"EMT RACEWAY (FIELD VERIFY EXACT LOCATION) FOR EXTENTION INTO TENANT SPACE - SEE KIOSKS ELECTRICAL PLAN, E1.1 SAO �►1 SIDE FIXTURES SHALL BE INSTALLED VERTICALLY FLAT IN COVE; FIXTURES SHOWN HORIZONTALLY OFFSET FOR CLARITY AND QU • ►-r RE COUNT ONLY - TYPICAL EXISTING 120/208V, 1PH, 3W LOAD CENTER AND ASSOCIATED RACEWAYS TO BE REMOVED. THE EXISTING PANEL HAS A FEED THAT IS ROUTE UP TO ABOVE/THROUGH CEIIJNG LEVEL. FIELD VERIFY IF THIS RACEWAY IS ROUTED TO PENTHOUSE 2AC AND RE -USE IF POSSIBLE FOR THE NEW COVE LIGHTING CIRCUIT. Ai OA A AL --- :rrrr' .I r , /l /I //% ! / :: *fir //z/.// // , / // / / / ///�!, .!a!i� %zrz / / i�/ 1 EXISTING POWER PULL-BOX - VERIFY DGACT LOCATION EXISTING COMMUNICATIONS PULL-BOX -- FIELD VERIFY EXACT LOCATION ELECTRICAL DEMOLITION PLAN Z0 SCALE 1/8" = 1' -0° TOP FIXTURES SHALL BE INSTALLED HORIZONTALLY FLAT IN COVE; FIXTURES SHOWN VERTICALLY OFFSET FOR CLARITY AND QUANTITY /FIXTURE COUNT ONLY. 17 FIXTURE TYPE SS1 - PROVIDE SINGLE -LAMP (F32T8, 3500K) STAGGERED STRIP LIGHT FIXTURE WITH ADJUSTABLE OVERLAP AND INTEGRAL HPF BALLAST -- BARTCO BFL255 SERIES 16 MOUNT J -BOX FLUSH IN NEW WALL AND FLEX TO FIXTURE AS SHOWN IN J -BOX DETAIL (THIS SHEET). - CIGFMNG- COl`TTROIS r•• • r 0 ) FLEX TO VERTICAL FIXTURES AS REQUIRED. PROVIDE ONE -HOLE STRAPS TO SNUG FLEX TIGHT TO WALL (TYPICAL) 13 PROVIDE FLEX CONNECTION TO FIXTURE AS REQUIRED. PROVIDE ONE -HOLE STRAPS (NOT SHOWN) AS REQUIRED TO PULL RACEWAY DOWN AS LOW (OUT OF VIEW FROM FLOOR BELOW) AS PRACTICAL J BOX FLUSH IN WALL WITH COVERPLATE PAINTED TO MATCH WALL MOUNT J -BOX AS LOW AS PRACTICAL IN COVE TO MINIMIZE VIEW FROM FLOOR BELOW. RACEWAY PER PLANS. LIGHT FIXTURE PER LIGHTING PLAN. J -BOX DETAIL SCALE: NONE q...r INS -- T�7 T —EL L L 142' -6" FIELD VERIFY REFER TO KIOSKS ELECTRICAL PLAN, E1.1 CONTINUATION T -7-11J .i El I FOR LIGHTING PLAN ELEVATION LE '2 SCALE: 1/8. 1' -O" LEGEND NOTES REVIEWED MPi.IANCE CODE A 70 - NEC MAY o 2008 --r-OtWfulwaa E ILDING DNS ION E RECEIVED MAY 162008 PERMIT CENTER ELECTRICAL DEMO & LIGHTING PLAN ELEVATION a) U 0 foE O 0 a) 14E'' w 73-07129-05 05 -09 -2008 NORDSTROM KEY PLAN [] 0 TITLE NORTH SCALE: 1/8" = 1' -D" 0 co 0 0 Architecture Engineering 'up inc., a Washington corporation, ALL RIGHTS RESERVED. ROUTE RACEWAY DOWN TO SERVICE CORRIDOR LEVEL TIGHT TO CORNER -- FIELD VERIFY EXACT ROUTING AS NEEDED PULL -BOX MOUNTED INSIDE S 1ARWELL AT SAME LEVEL AS ROOF MOUNTED RACEWAY - FIELD VERIFY EXACT LOCATION AS NEEDED (TYPICAL) RACEWAY ROUTED ACRD$ ROOF ON TREATED 4"X4" SLEEP FIELD VERIFY EXACT ROUTING AS REQUIRED (TYPIC 4 ) 3/4 °C FOR C UG CONNECT TO EXISTING SPARE 20A /1P BREAKER (HJA -2) IN SECTION 2 OF PANEL HJA. ROUTE CIRCUIT THROUGH SPARE CONTACTOR #3 IN EXISTING LIGHTING CONTROL ENCLOSURE. EXISTING METERED SWITCHBOARD, TMBJ 4 3#10 VE EXISITNG TELEPHONE BACKBOARD, T.J33.1.H4.251. WB APPR. IMATE LOCATION OF EXISTI G PENTHPUSE AC -2 (ON RQ0F) - F1ELD VERIFY EXACT LOCATION EXISTING COVE LIGHTS CONTACTORS & ENCLOSURE EXISTING PANEL HJA SECT. 1 (BOTTOM) & SECT. 2 (TOP) EXISTING PANEL LJA SECT. 1 & SECT. 2 EXISTING CONTACTORS & ENCLOSURE RR9V E- -WJLL--- BOXE IN SERVICE COOK R AS REQUI D (TYPI) ROUTE RACEWAYS OVERHEAD ON UNI -STRUT TRAPEZE WITH THREADED ROD TO STRUCTURE ILA :T..r_ -aiM 11 31 ADJUST AS 3/4"C, 3 #10 FOR COVE LIGHTS (2) 2" WITH PULL CORD IN EACH FOR POWER TO KIOSKS (1) 1 -1/4 "C WITH PULL CORD FOR TELEPHONE TO KIOSKS FIELD LOCATE PULL BOXES DIRECTLY ABO' TRENCH TO MINIMIZE BENDS. ROUTE RACEWAYS TIGHT TO WALL AND PROVIDE RACEWAY 0 INTO TRENCH AS REQUIRED NEW TR TRENCH REQUIRED EXISTING EXISTING TRENCH SHOWN WITH LIGHT HATCH EXISTING PRETZEL TIME FRUIT TUTTI NEW TRENCH SHOWN EXISTING TRENCH AS RE GROUT TO MATCH EXIST! (TYPICAL) DARK HATCH - EXTEND UIRED. PATCH, FILL, RE -TILE & FINISH FLOOR AS REQUIRED - 3/4 "C, 3,'� UGHTING UGHTING PLAN CONTINUATION 'k]ALI CI OU FOR N E1.0 AS PLAN, E1.0 FOR EXISTING CONDUIT TO BE EXTENDED. PROVIDE FLUSH MOUNTED 4S (DEEP STYLE) DEVICE BOX SINGLE GANG M D RING FOR FUTURE TENANT TELEPHONE JA (TYPICAL) -7D VIDE FL M DJ (SIZE AS REQUIRED) FOR FUTURE TENANT POWER EXTENTION W'84900 It FIELD VERIFY EXACT Li ATION OF EXISTING POWER PULL -BOX AT PRETZEL -T1ME TENANT D EXTEND AS INDICATED. 2" WITH PULL CORD IN EACH FOR POWER TO KIOSKS 1 -1/4" WITH PULL CORD IN EACH FOR TELEPHONE PATHWAY TO KIOSKS — — 2' WITH PULL CORD IN EACH FOR POWER TO KIOSKS 3/4 "C WITH PULL CORD FOR TELEPHONE TO EACH TENANT ELECTRICAL KIOSKS PLAN SCALE: 1/8° = 1.--0" LEGEND NOTES RENEWED FOR CODE, COMPLIANCE NFPA 70 MAN 202008 City Yukon ION B ILDIN DM ELOS(t'O( RECEIVE) MAY 16 2008 PERMIT MIER ELECTRICAL KIOSKS PLAN c (li o up) L 176 (73 c 3 w> 0 c a) cr.- -= ‘.5 0 ap T® 21 w 73- 07129 -05 05 -09 -2008 KEY PLAN WORK IN THIS AREA x5.1; IM TITLE NORTH SCALE: 1/8" = 1' -0" 0 a) d) c w Architecture ©2008, DLL? Group inc., a Washington corporation, ALL RIGHTS RESERVED. PANEL SCHEDULE PANEL: HJA LOCATION: VOLTS: 480 Y/ 277 PH: 3 -Phase W: 4 -Wire AMP MAIN BRKR: AMP MLO: 400 SCCR: 14,000 MOUNT: FED FROM: MAIN SWBD CIRCUIT DESCRIPTION LOAD VA CKT BKR P CIR # P H CIR # P CKT BKR LOAD VA CIRCUIT DESCRIPTION SECTION I LTS - COVE 3300 20 1 1 A 2 1 20 1280 LIGHTS - ENTRY COVE LTS - COVE 3300 20 1 3 B 4 1_ 20 SPARE LTS - SERVICE CORRIDOR 400 20 1 5 C 6 1 20 SPARE SECTION II H -20 CIRC. PUMP (3 /4HP) 443 15 3 1 A B 2 3 20 4432 R -2 AIR COND - 443 - --- 3 4 - - 4432 - - 443 - - 5 C 6 -- - 4432 - H-28 HEAT UNIT 4432 20 3 7 A B 8 3 30 SUB -FEED SECT10N I (LOADS ADDED IN SECTION I ABOVE) - 4432 - - 9 10 - -- - - 4432 - - 11 C A 12 - - - SPARE 15 3 13 14 3 15 3324 2A ENTRY HEAT - - - 15 B C A B 16 - - 3324 - - - - 17 18 -•• - 3324 - SPACE 3 19 20 3 SPACE -- - - 21 22 - - - - - - 23 C A B C A B C 24 - - - SUB FED LJA 27713 125 3 25 26 X X BLANK - 27713 -- - 27 28 X X BLANK - 27713 - - 29 30 X X BLANK 5 -2 AIR COND 19884 175 3 31 32 X X BLANK - 19884 - - 33 34 X X BLANK - 19884 - - 35 36 X X BLANK EXISTING CO ECTE 1 DEN A \3 PA EL JA LOAD SUMMARY; CONNECTED FEEDER 1 SERVICE CALCULATION LIGHTING LARGEST MOTOR MOTORS RECEPT KITCHEN EQUIPMENT ELECTRONIC LOADS ELECTRIC HEATING MISC. 7.00 KVA 0.00 KVA 32.08 KVA 0.00 KVA 0.00 KVA 0.00 KVA 65 -47 KVA 83.14 KVA 8.75 KVA (125 %) 0.00 KVA (125 %) 32.08 KVA (100 %) 0.00 KVA (10KVA 100 %, REMAIN ® 50 %) 0.00 KVA (65 %) 0.00 KVA (100 %) 65.47 KVA (100 %) 83.14 KVA (100 %) TOTALS 188 KVA 226 AMPS 189 KVA HI -PHASE 228 AMPS 232 A PSE, PAD MOUNTED TRANSFORMER 8B2927 (V13) 1000 KVA 480/277V, 30, 4W TO PSE VAULTS g-. V10 AND V12 (4)4 "C: 4 #60OKCMIL CU OR (5)4 "C: 4 #75OKCMIL AL X/R - 8 %Z = 5.3% 22,600A SYMM ASC! \EW CO\ \ECTE3/DEMAND PA \EL HJA LOAD SUMMARY: CONNECTED FEEDER / SERVICE CALCULATION LIGHTING LARGEST MOTOR MOTORS RECEPT KITCHEN EQUIPMENT ELECTRONIC LOADS ELECTRIC HEATING MISC. 8.28 0.00 32.08 0.00 0.00 0.00 65.47 83.14 KVA KVA KVA KVA KVA KVA KVA KVA 10.35 KVA (125 %) 0.00 KVA (125 %) 32.08 KVA (100 %) 0.00 KVA (10KVA © 100 %, REMAIN @ 50 %) 0.00 KVA (65 %) 0.00 KVA (100 %) 65.47 KVA (100 %) 83.14 KVA (100 %) TOTALS 189 KVA 227 AMPS 191 KVA HI -PHASE 230 AMPS 238 A TO A.C. PENTHOUSE #4 - -� TUNNEL f MAIN SWITCHBOARD, 480Y/277V, 30, 4W, 2000A, 1OOKAIC (4)6 "C: 4 #600KCMIL CU OR (5)6 "C: 4 #75OKCMIL AL LOADING DOCK VAULT V66 TO A.C. PENTHOUSE #3 TO A.C. PENTHOUSE #5 70 A.C. PENTHOUSE #6 TO A.C. PENTHOUSE. #7 PANEL P.4 480Y/277V 30, 4W 400A NEW LOAD ADDED -.._. -1 - ._- 75KVA 480V 208Y/120V 3%% C 4W L LJ f ('v l PANEL LHD 480`f /277V 30 4W 2:'5A SEC 110N1 PANEL LHD 480Y/277V 34, 4W 225A SEC110N2 1- 1 L- cr 0 0n 0 _ 0 V) C% F-' Ch LLJ V) l.- 0 0 0 L) 0 L. V) PANEL P8 480Y/277V 30, 4W 225A r A.C. PENTHOUSE #2 PANEL LJA 208Y/120V ..30, 4W 225A SECTION 1 PANEL HJA 480Y/277V 30, 4W 400A PANEL LJA 208Y/120V 30, 4W 225A SECTION 2 45KVA 480V 1 208Y/120V 3%% C 4W 3- 1/2 "C, d #350MCM VOI. TA GE REGULATOR Root I%VH. TO A.C. PENTHOUSE #1 V) 5 V) 5 0 Li R 0, CL a 0 Y S Tf Z d C Q 0) j 4 tY 0 w 0 d U " s G U MALL LEVEL LEGEND NOTES KEY NOTES: 01 EXISTING PANEL AFFECTED BY THIS PROJECT, REVIEWED FOR CODE COMPLIANCE C NFPA 70 A MAY 20 X008 • �y � Tukvuila 1LDYNG DM ION ELo 8 cpso RECEIVED MAY 1 6 2008 PERMIT CENTER ELECTRICAL ONE -LINE DIAGRAM & PANEL SCHEDULE a) t..°°' 2 0 a. co ee („) OD U ‘5'5( Interior Renovation at c1 w 73- 07129 -05 05 -09 -2008 KEY PLAN Q 0022 (73 Q) CL t Lem .N Q) rflb 1..1J N a) V a W ©2008, DLR Group Inc., a Washington corporation, ALL RIGHTS RL