HomeMy WebLinkAboutPermit EL08-0606 - WESTFIELD SOUTHCENTER MALL - PARFUMERIEPARFUMIERE
446 SOUTHCENTER MALL
ELO8-606
Cityllbf Tukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 6364200010
Address: 446 SOUTHCENTER MALL TUKW
Suite No:
ELECTRICAL PERMIT
Permit Number: EL08 -606
Issue Date: 05/23/2008
Permit Expires On: 11/19/2008
Tenant:
Name: PARFUMERIE
Address: 446 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: STEVE MARVICH Phone: 206 - 391 -6857
Address: 828 POPLAR PL S , SEATTLE WA
Contractor:
Name: 5 M E INC OF SEATTLE
Address: 828 POPLAR PL S , SEATTLE WA
Contractor License No: SMEINS *066DB
Phone: 206 329 -2040
Expiration Date: 03/02/2010
DESCRIPTION OF WORK:
WIRE RETAIL TENANT SPACE INCLUDING FEEDER 480V PANEL, TRANSFORMER AND 120/208V
PANEL
Value of Electrical: $22,400.00
Type of Fire Protection:
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature: flJ J &'
I hereby certify that I have read and
governing this work will be complie
Fees Collected:
National Electrical Code Edition:
$574.00
2005
Date: 612-13
ed this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
The granting of this ? ' 't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th- . - ormance of work. I am authorized to sign and obtain this electrical permit.
Signature: ` ` ' _ Q Date: 5— /2- —3}
Print Name: C C/ `% u i C
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -606 Printed: 05-23 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 6364200010
Address: 446 SOUTHCENTER MALL TUKW
Suite No:
Tenant: PARFUMERIE
PERMIT CONDITIONS
Permit Number: EL08 -606
Status: ISSUED
Applied Date: 05/19/2008
Issue Date: 05/23/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating constru lion or the performance of work.
Signature:
�f
Print Name: i'e V auptie
Date:
doc: Cond -Elec
EL08 -606 Printed: 05-23 -2008
CITY OF TUKWII
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
httn: /iW ww. ci. tukwila. wa. us
Electrical Permit No. 6 -0 1 d (,
Project No rob 'O8
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: `I' /�,(P r"�? 0i3 ( 0
Site Address: ! 7 �t�u��'Suite Number: 3T 7 Floor:
Tenant Name: F' ARFt)�kttilc��P�c
Property Owners Name: W -6T--p I A -C 14441,1,-
Mailing Address:
New Tenant: ® Yes ❑..No
City
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: S"1-eVe Mew I/ (G�
Mailing Address: /" 8'p
E -Mail Address:
Day Telephone:
:saw
City
Fax Number:
State Zip
ELECTRICAL CONTRACTOR INFORMATION
Company Name: C5-0,t !/l/ c 777 .
- �L- S s
Mailing Address:
Contact Persona
City State Zip
L t , .4 v t Day Telephone:
E -Mail Address $ -1. Q k tS'liLte l 4 ea+ I e , Cply� Fax Number:
�ZeY� - 39 �- 6 t/� 7
2-e. ` 7 z - �46'
Contractor Registration Number: Expiration Date:
Valuation of of Project (contractor's bid price): $
e27 Ora
Scope of Work (please provide detailed information):
Will service be altered ?j IS, Yes
Type of Use: TCX►L/ l
Type of work:
❑ No Adding more than 50 amps? ❑ Yes
No
121-New ❑ Addition ❑ Service Change
❑ Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
Puget Sound Energy
❑ Seattle City Light
HA ApplicationetForms- Appl ¢ atwns On Lme \4-2007 - Electrical Permit Appbcadon.doc
hh
❑ Remodel
❑ Telecommunication
❑ Tenant Improvement
❑ Temporary Service
Page 1 of 2
1
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings
(including an attached garage)
❑ Garages, pools, spas and outbuildings
❑ Low voltage systems
(alarm, fiance thermostat)
$140.00
$75.00 ea
$55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES,
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN R OR ELECTRICAL CONTRACTOR:
Signature % Date:
Print Name:
Mailing Address:
Day Telephone:
a
City
IDate Application Accepted:
Date Application Expires: I
Staff Initials:
H: Applicenoas \Fame- Applications On Line\4 -2007 - Electrical Pamir Apptiutim.doc
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -606
Address: 446 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 05/19/2008
Applicant: PARFUMERIE Issue Date:
Receipt No.: R08 -01797
Payment Amount: $459.20
Initials: JEM Payment Date: 05/23/2008 11:28 AM
User ID: 1165 Balance: $0.00
Payee: SME, INC. OF SEATTLE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 21114 459.20
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 459.20
Total: $459.20
2803 05/23 9711 TOTAL 45920
doc: Receiot -06 Printed: 05-23 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -606
Address: 446 SOUTHCENTER MALL TUICW Status: PENDING
Suite No: Applied Date: 05/19/2008
Applicant: PARFUMIERE Issue Date:
Receipt No.: R08 -01708
Payment Amount: $114.80
Initials: WER Payment Date: 05/19/2008 01:35 PM
User ID: 1655 Balance: $459.20
Payee: S M E INC OF SEATTLE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash 114.80
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.0 114.80
Total: $114.80
r1nr. Rarpint -OR
PrintArI• n5- 154-2nnR
INSPECTION RECORD
Retain a copy with permit
Ec o'- (off
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 114
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 t36 0
INSPECTION NO.
Project: rA I6
Type of Inspection:
,./00
V
Address:
qt, 'ski
Date Called:
Special Intructions:
Date Wanted:
%
-7 21
' a.m.
e„.., /...s
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval
COMMENTS:
. rik)4/t.
Inspector:
Date:
ink-1 ai
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
EL(18-Gob
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: fhltEkkirjkif
Type of Inspection:
/Q 0
Address: /pit, i Pl k'
Date Called:
Special Instructions:
Date Wanted:
.....
m.
Requester:
Phone No:
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
- • i •
Can/pi r r F I LL-
Dtkdn 4()
(Inspector:
-Tiavi 6644
Date: 01 /i`iCk
ri $60.00 REINSPECTION FEE REQUI ED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
owr�nd— _ .a.Sar
•
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
ti
Project: PA•KrIPI6K I t
Type of Inspection: 7o 3
O
Address: q 14 (0
iltft.
Date Called:
Special Instructions:
- 5
Date Wanted:
?fel
Pan.;
Requester:
CflLIA)
Phone No:
p.-
, A)
Approved per applicable codes. LJ Corrections required
prior to approval.
COMMENTS:
- 5
... (.,Lftoo
CflLIA)
p.-
, A)
Inspector:
Date: 07/01 J08
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION it
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: _ FAcorktek
Type of Inspection:
7003
Address: ii. q (ft 1411141 '
W
Date Called:
Special Instructions: '
Date Wanted:
/03
p.m.
Requester:
Phone No:
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
Pq
D. �• - M,fi 44100 ctPr
5 To eF(o sir
Inspector: ik-Wec
Date: D7/03 l ag
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT
CITY OF TUKWILA BUILDING DIVISION g
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
NO.
Project: � ice f
f/Kfitiii /t-
Type of Inspection:
µ W
y,
Date Called:
Special Instructions:
Date Wanted: / �f %Z7
p.m.
Phone No:
ved per applicable codes. Corrections required prior to approval.
Inspe
./1- o1 !/.JI/7 /C
Dateth 7/06'
n$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
PLAN REVIEVel %ROUTING SLIP
ACTIVITY NUMBER: EL08 -606 DATE: 05 -19 -08
PROJECT NAME: PARFUMIERE
SITE ADDRESS: 446 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEP��ARTMMEENTS:
Bu``wdng Divis of
Public Works
Lam'
1
-of
Fire Prevention
Planning Division
Structural n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-20-08
Complete
Comments:
Fy
Incomplete
n
Not Applicable
❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS RO TING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
nNo further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
DUE DATE: 06 -17 -08
Approved n Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
■ 120 VOLT CIRCUIT
REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD
SPECIFICATIONS
•
TIME CLOCK
BEIElfgEni
OVERRIDE
SWITCHES
'c.'
• SIGN LIGHTS
pie y- 'LIGHTS
Th.PCKLIGHTS
I^2.
0\B1 r LT5
L-10
•pq(K LIGHTS
1w1.4
TOcK Lr('
L-6
(LIGHT SWITCHING DETAIL
NOT TO SCALE
LIGHTS
LS
LOAD TYPE
Lighting
Receptacles
Water heater
Sign
HVAC
HVAC
Totals
Amps @ 480V 30
2001 Washington State Nonresidential Energy Code Compliance Form
2001 Wa51Ungten State Nonresidential Energy Code Compliance Forms
June 2001 - KJM
Project Info
PANEL: "h"
Number of
Fbdures
Date
5/19 /2008
344 southcenter gill
i I
ForBuilding
Department Use
IC
I
i
Tukril_La, SA 98188
Applicant Name: are Ina. of Seattle
Applicant Address: 822 Poplar Pl. So.,
Seattle, MA 98144
Applicant Phone: (208) 789 -3809
VOLTS: 120/208
VOLTS: 120/208
PHASE:
3
3
i
i_ J..
...
MAIN BKR
X
GROUND
GROUND
AMPS: 125
WIRE:
4
WIRE:
..........
LOAD
4
CB
MAIN LUGS
BUS
SURFACE
I
SURFACE
�
DESCRIPTION
A
B
C
A/P
A/P
A
B
C
1
DESCRIPTION
LOAD
1
CB
450
CB
•
LOAD
20/1
400
_
DESCRIPTION
A
_ B
C
A/P
_
Lighting
675
A/P
A
B
C
DESCRIPTION
20/1
1
VAV 1
2,500
Track Lighting
20/3
•
Pendant lighting
100/3
2,480
_
75 KVA Trans
2
3
VAV 1
2,500
20/3
6
•
Lighting
100/3
2,855
20/1
75 KVA Trans
4
5
_ VAV 1
400
2,500
20/3
Track Lighting
Case Lighting
8
10
•
_
100/3
-
2,690
75 KVA Trans
6
7
VAV 2
2,500
1,000
20/3
•
GFCI Receptacle
180
20/1
8
9
VAV 2
, 2,500
20/3
12
•
Show window recut.
360
20/1
+
10
11
VAV 2
750
,
2,500
20/3
14
•
Storage receptacle
180
20/1
12
13
_ ,
0
•
16
17
Retail recepts
720
14
15
•
0
•
18
19
0
0
600
16
17
•
0
•
20
21
0
18
,19
20/1
_
•
-
•
,
0
22
23
20
21
0
•
•
0
_
0
24
25
22
23
•
•
0
26
_
24
25
0
•
,
0
26
27
0
•
•
0
0
28
29
31
0
•
•
0
0
30
32
33
0
•
•
0
34
35
•
•
0
36
37
•
•
0
38
39
•
-
•
�.
40
41
•
•
42
930
1,455
1,540
5,000
5,000
5,000
1,150
2,480
2,855
2,690
TOTAL PH. A
2,480
120
VOLTS
TOTAL PH. A
7,480
277
VOLTS
AMPS
27.00
AMPS
TOTAL PH. B
2,855
r
VOLTS
TOTAL PH. B
7,855
277
VOLTS
23.79
AMPS
28.36
AMPS
TOTAL PH. C
2,690
120
TOTAL PH. C
7,690
_ 277
VOLTS
22.42
AMPS
27.76
AMPS
_
■ 120 VOLT CIRCUIT
REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD
SPECIFICATIONS
•
TIME CLOCK
BEIElfgEni
OVERRIDE
SWITCHES
'c.'
• SIGN LIGHTS
pie y- 'LIGHTS
Th.PCKLIGHTS
I^2.
0\B1 r LT5
L-10
•pq(K LIGHTS
1w1.4
TOcK Lr('
L-6
(LIGHT SWITCHING DETAIL
NOT TO SCALE
LIGHTS
LS
LOAD TYPE
Lighting
Receptacles
Water heater
Sign
HVAC
HVAC
Totals
Amps @ 480V 30
2001 Washington State Nonresidential Energy Code Compliance Form
2001 Wa51Ungten State Nonresidential Energy Code Compliance Forms
June 2001 - KJM
Project Info
PANEL: "L"
Number of
Fbdures
Date
5/19 /2008
344 southcenter gill
i I
ForBuilding
Department Use
IC
I
i
Tukril_La, SA 98188
Applicant Name: are Ina. of Seattle
Applicant Address: 822 Poplar Pl. So.,
Seattle, MA 98144
Applicant Phone: (208) 789 -3809
VOLTS: 120/208
It I i
i
PHASE:
3
i
i_ J..
...
MAIN BKR
X
GROUND
AMPS: 200
WIRE:
..........
LOAD
4
CB
MAIN LUGS
CB
BUS
LOAD
I
SURFACE
�
DESCRIPTION
A
B
C
A/P
A/P
A
B
C
1
DESCRIPTION
1
Sign Circuit
450
20/1
•
20/1
400
_
Track Lighting
2
3
_
Lighting
675
20/1
,
•
20/1
400
Track Lighting
4
Pendant lighting
640
20/1
•
20/1
400
Track Lighting
6
.5
7
Lighting
120
20/1
•
20/1
400
_
Track Lighting
Case Lighting
8
10
9
Spare
-
20/1
•
2011
1,000
11
GFCI Receptacle
180
20/1
•
20/2
750
Water Heater
12
13
Show window recut.
360
20/1
+
20/2
750
14
15
Storage receptacle
180
20/1
•
_ ,
0
_
16
17
Retail recepts
720
20/1
•
0
18
19
POS recept
0
600
20/1
•
0
20
21
0
20/1
•
0
22
23
0
•
0
24
25
0
•
0
26
27
0
•
0
28
29
0
•
0
30
31
0
•
0
32
33
0
•
0
34
35
0
•
0
36
37
•
0
38
39
-
•
�.
40
41
•
42
930
1,455
1,540
1,550
1,400
1,150
TOTAL PH. A
2,480
120
VOLTS
20.67
AMPS
TOTAL PH. B
2,855
120
VOLTS
23.79
AMPS
TOTAL PH. C
2,690
120
VOLTS
22.42
AMPS
_
■ 120 VOLT CIRCUIT
REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD
SPECIFICATIONS
•
TIME CLOCK
BEIElfgEni
OVERRIDE
SWITCHES
'c.'
• SIGN LIGHTS
pie y- 'LIGHTS
Th.PCKLIGHTS
I^2.
0\B1 r LT5
L-10
•pq(K LIGHTS
1w1.4
TOcK Lr('
L-6
(LIGHT SWITCHING DETAIL
NOT TO SCALE
LIGHTS
LS
LOAD TYPE
Lighting
Receptacles
Water heater
Sign
HVAC
HVAC
Totals
Amps @ 480V 30
2001 Washington State Nonresidential Energy Code Compliance Form
2001 Wa51Ungten State Nonresidential Energy Code Compliance Forms
June 2001 - KJM
Project Info
Project Address Parf,i,ie
Number of
Fbdures
Date
5/19 /2008
344 southcenter gill
i I
ForBuilding
Department Use
IC
I
i
Tukril_La, SA 98188
Applicant Name: are Ina. of Seattle
Applicant Address: 822 Poplar Pl. So.,
Seattle, MA 98144
Applicant Phone: (208) 789 -3809
Project Description
El
New Building ❑ Addition ❑ Alteration El Plans Included
Indicate controls (Sections 1513) including commissioning requirements on plans.
Compliance Option
Prescriptive Q Lighting Power Allowance 0 Systems Analy 4Is
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces dearly on pans.)
Alteration Exceptions
(check appropriate box)
• No changes are being made to the lighting
Number of
Fbdures
❑ Less than B0% of the fixtures are new, and installed lighting wattage is not being Increased
Maximum Allowed Lighting Wattage (Interior)
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ftz "
Area in ftz
Allowed x Area
Ground Floor
Retail
1.50
970.0
1455.0
Ground Floor
Storage
0.50
65.0
32.5
Fround Floor
Restrocm
8.00
30.0
240.0
From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts
Notes:
1. Use manufacturers listed maximum input wattage. For hard -wired ballasts only, the
default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fixture.
Proposed Lighting Wattage (Interitityst all fixtures. For exempt lighting, not exception and leave Watts/Fbcture blank.
1727.5
Location
(floor /room no.)
Retail
Fixture Description
"A" pendant fluorescent
Number of
Fixtures
5
Watts/
Fixture
18.0
Watts
Proposed
90.0
Retail
Retail
Retail
Storage
Restroam
"5" pendant incandescent
"c" recessed incandescent
"D" recessed +++,a*Aeeaent
"E" grid fluorescent
"p" wall fluorescent
11
3
5
1
1
50.0
100.0
75.0
90.0
30.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
Maximum .Allowed Lighting Wattage (Exterior)
Location
Covered Parking
(standard paint)
Description
bon
Allowed Watts
per ftz or per If
Area in ftz
(or If for perimeter)
550.0
300.0
375.0
90.0
30.0
1435.0
Allowed Watts
xftz
(or x ft)
Covered Parking
(reflective paint)
Open Parking
Outdoor Areas
0.2 W
0.3 W/ft2
0.2 W/ftz
Bldg. (by facade)
Bldg. (by perim)
0.2 W/ftz
0.25 W/ft2
7.5 Wnf
Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts
Use mtgr fisted maximum input wattage. For tuaures with hard -Kirea oauatts only,
Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used.
Location
Fixture description
Number of
Fbdures
Watts/
Fixture
Watts
Proposed
i I
1 1
PILE COPY
Permit No.
PIar+ review approval is erect to errors and
Appr4val of ins.
the violation of �� does � lie
of approved R -:d Copy and ��. Receipt
,� ' �d8ed:
Track Lighting Exempt
t5 Watts /sq' maximum
Cabinet lighting exempt
Date:
City of Tuba
PLI!LOINO DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees. (
Connected KW
4
2.01
1.5
0.45
7.5
7.5
22.96
27.63
Factor Demand KW Voltage Phase
1.25 5 120 1
1 2.01 120 1
1 1.5 208 1
1.25 0.5625 120 1
1.25 9.375 480 3
1 7.5 480 3
25.9475
31.22
480 3
181 -10"
GWB CEILING
AT 7' -6"
WALL LIGHT
TOILET
ROOM
` p F u..c.re L
1 Yl C'a4j`1(1+ --
PROVIDE TELECOM
CONN. TO TWO
P.O.S. LOCATIONS
2
At
PROVIDE POWER
TO GLASS
DISPLAY CASE
INTERNAL LIGHTING
ALL LIGHTING
FORWARD OF
THIS LINE TO SHARE
7 DAY TIMER WITH
SIGN CIRCUIT
SEPARATE PERMIT
REQUIRED FOR
Imechenlosi
� Electrical
P1
Veas RAO
City of Tukwila
BUILDING DIVISION
PA\
-r- r
Ago °��
loca,"°
EL RISER DIAGRAM
277/480V 3 PH,
4 WIRE ELECTRICAL
SERVICE
FLOOR
VERIFY EXISTING CONDITIONS AND
REQUIREMENTS PRIOR TO BIDDING AND
INSTALLATION.
EXISTING ELECTRICAL
DISTRIBUTION SYSTEM(S)
FOR OTHER TENANTS
EXISTING LANDLORD WIREWAY
LANDLORD 1TENANT
NEW
PANEL
H'
NEW
PANEL
PROVIDE AND INSTALL
GROUND TO BUILDING
STEEL PER N.E.C.
3`
LANDLORD'S ELEC. ROOM
EXIST. CMU WALL-
/ MAINTAIN 1 HOUR RATING
TOILET
ROOM
STOCK ROOM
X BRACE
A
4'
P.Q.S.
c7
111
I .
1
EQUAL
_ASS STOREFRONT LINE ABOVE
101 -0" DATUM, ON LEASE LINE
,.a >temxe eiA7e xtmas ae sa >R- m mm 9ilR maimane >a mO7RA>RQ
GLASS STOREFRONT LINE AT FLOOR
NEUTRAL PIER BY L.L.
m m ba is Pi
RISER DIAGRAM NOTES BY SYMBOL
• 9.2 1-144/414) (4) ;11 /o THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE
2 1 t.At1D1:.ORD METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS.
® lay L-Ft 3 L.V W D AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE VERIFY
LOCATION IN flr_W.
• [3; Lic03 a0-D
® 8J L- ti 0 rib
0 V/W Ba 12. x
• VAV 13OX .tt 12.x3
® VAV
O VAV
10 NOT USED
11 PROVIDE AND INSTALL (3) 11/0 THWN CU, IN 1 -1/4' CONDUIT FOR TRANSFORMER.
g PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER.
13 PROVIDE AND INSTALL (3) ,i.3 /o THWN CU, (1) 16 GROUND IN 2' CONDUIT FOR PANEL
14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW VANDOW AND SIGNAGE. PROVIDE NEW AS
REQUIRED
EL08 o4, •
828 Poplar Place South
Seattle, Washington 98144
Phone: (206) -329 -2040
Web Site: www.smeincofseattle.com
co
co
T
co
on)
z
0
V
z
H
cf)
J
J
ISSUED DATE 05 -19-08
Project Manager. STEVE MA.RVICH
Design: STEVEMARVICH
Drufier: STEVEMARVICH
Job Number. 00-000
Recived Architects Plan 5 -19-08
SME REVISIONS
REV
DATE
DESCRIPTION
1
04-17-08
X
RECE1VEr
NAY 192006
PERMIT CENTI-t
E1 .0
issi__I--\-1-Si
1 1
i I
1 1
j i
i a
_ __r--
1 l I
I
'---r- just_
It I i
i
r
i
I
I
1
1
i
i_ J..
...
1
c7
111
I .
1
EQUAL
_ASS STOREFRONT LINE ABOVE
101 -0" DATUM, ON LEASE LINE
,.a >temxe eiA7e xtmas ae sa >R- m mm 9ilR maimane >a mO7RA>RQ
GLASS STOREFRONT LINE AT FLOOR
NEUTRAL PIER BY L.L.
m m ba is Pi
RISER DIAGRAM NOTES BY SYMBOL
• 9.2 1-144/414) (4) ;11 /o THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE
2 1 t.At1D1:.ORD METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS.
® lay L-Ft 3 L.V W D AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE VERIFY
LOCATION IN flr_W.
• [3; Lic03 a0-D
® 8J L- ti 0 rib
0 V/W Ba 12. x
• VAV 13OX .tt 12.x3
® VAV
O VAV
10 NOT USED
11 PROVIDE AND INSTALL (3) 11/0 THWN CU, IN 1 -1/4' CONDUIT FOR TRANSFORMER.
g PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER.
13 PROVIDE AND INSTALL (3) ,i.3 /o THWN CU, (1) 16 GROUND IN 2' CONDUIT FOR PANEL
14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW VANDOW AND SIGNAGE. PROVIDE NEW AS
REQUIRED
EL08 o4, •
828 Poplar Place South
Seattle, Washington 98144
Phone: (206) -329 -2040
Web Site: www.smeincofseattle.com
co
co
T
co
on)
z
0
V
z
H
cf)
J
J
ISSUED DATE 05 -19-08
Project Manager. STEVE MA.RVICH
Design: STEVEMARVICH
Drufier: STEVEMARVICH
Job Number. 00-000
Recived Architects Plan 5 -19-08
SME REVISIONS
REV
DATE
DESCRIPTION
1
04-17-08
X
RECE1VEr
NAY 192006
PERMIT CENTI-t
E1 .0