HomeMy WebLinkAboutPermit EL08-0654 - WESTFIELD SOUTHCENTER MALL - TUTTI FRUTTI FROZEN YOGURTTUTTI FRUTTI
FROZEN YOGURT
2800 SOUTHCENTER MALL
K -0305
ELO8-654
Cit3111bf Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
Parcel No.: 6364200010
Address: 2800 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: EL08 -654
Issue Date: 07/18/2008
Permit Expires On: 01/14/2009
Tenant:
Name: TUTTI FRUTTI FROZEN YOGURT
Address: 2800 SOUTHCENTER MALL, K0305 , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: MARCIA PEDDICORD Phone: 818 402 -8923
Address: 633 SOUTHCENTER MALL, TRAILER 3 , TUKWILA WA
Contractor:
Name: J R ELECTRIC INC
Address: PO BOX 7900 , KENT WA
Contractor License No: JRELEI *022QB
Phone: 253 630 -8553
Expiration Date: 11/02/2008
DESCRIPTION OF WORK:
ALL ELECTRICAL WORK FOR NEW RETAIL KIOSK
Value of Electrical: $1,500.00
Type of Fire Protection:
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
'th,
Fees Collected:
National Electrical Code Edition:
$130.00
2005
Date: �� (�)
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or = •e o ce of work. I . authoriiz- to sign and obtain this electrical permit.
Signature:
Print Name:
A/13/",
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date:
/7 -fr
doc: EL -4/07
EL08 -654 Printed: 07 -18 -2008
Parcel No.: 6364200010
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
2800 SOUTHCENTER MALL TUKW
TUTTI FRUTTI FROZEN YOGURT
Permit Number:
Status:
Applied Date:
Issue Date:
EL08 -654
ISSUED
05/29/2008
07/18/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating o truction or the performance of work.
Signature:
Print Name: 1457
Date:
doc: Cond -Elec
EL08 -654 Printed: 07 -18 -2008
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.cltukwila.wa.us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
TE• LQOATI'
a
Site Address: K -0305 - South Center Mall
Tenant Name: Tutti Frutti Frozen Yogurt
Property Owners Name: Westfield Corporation
11601 Wilshire Blvd.
Mailing Address:
King Co Assessor's Tax No.: 636420 -0010
Suite Number: Floor: 13
New Tenant: ® Yes ❑..No
Los Angles
City
CA
state
90025
zip
y •;or �+ct^'S x i � yr k'w,' r
try • aLl a
o do the contact iy eu Tar; rmit.'
rW%.'{a,�
Name: Marcia Peddicord
Mailing Address: 633 South Center - Trailer #3
E -Mail Address: mpeddicord @us.westfield.com
Day Telephone: cell: 818- 402 -8923
Tukwila WA 98188
City
Fax Number:
State Zip
Company Name: C&J Technical Solutions and Services, Inc.
Mailing Address: 4000 Valley Blvd.
Walnut,
CA
91789
City - state Zip
Contact Person: John Jolly, PE Day Telephone: 909 - 598 -6067
E -Mail Address: Fax Number: 909 - 598 -6089 •
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $ 1 540
i" (Scope of Work (please provide detailed information): I Lr,- �c�.,,`r ��� � �-,r,: — � t
e 1 ► csy hW` -,rk ''-r ne re { I kia
Will service be altered? - ❑ Yes ® No
Type of Use:
Type of work;
2 New ❑ Addition ❑ Service Change 0 Remodel t9 Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Adding more than 50 amps? ❑ Yes 'Sv No
Property Served by:
Puget Sound Energy
❑ Seattle City Light
H :IApplicationeiporms-Applientims On Line b1-2007 - Ekcnical Permit Applicadms4oe
bh
Page 1 of 2
•
RESIDENTIAL
NEW RESIpENTIAL SERVICE
❑ New single family dwellings 5140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration S75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) S7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
PEntrf VrticATio,N ;
MULTI- FAMILY AND COMMERCIAL
Fees are based on the vahiation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
a�266 /
Signature. Date: , `
Print Name: — �f-,�' C/ - C Day Telephone:
('
Mailing Address: ' `V ��' j C7 � �,�.�Q�l
City
Date Application Accepted /, I M I Date Application Expires:
111AppliafuwslFotms- Apptiatines On LineW -7007 - aketrid Permit Appliention.dac
Lh
State Zip
(2i (2
Staff Initials:
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http://www.d.tukwilama.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -654
Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 05/29/2008
Applicant: TUTTI FRUTTI FROZEN YOGURT Issue Date:
Receipt No.: R08 -02604 Payment Amount: $104.00
Initials: WER Payment Date: 07/16/2008 10:49 AM
User ID: 1655 Balance: $0.00
Payee: KEVIN LEE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1539 104.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 104.00
Total: $104.00
4918 07/16 9710 TOTAL 104.00
doc: Receipt-06 Printed: 07 -16 -2008
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //wx w. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R08 -01843
Initials: JEM Payment Date: 05/29/2008
User ID: 1165 Total Payment: 627.80
Payee: KEVIN C. Y. LEE
SET ID: S000001036 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -304 566.80
4ci=i 26.00
�' r:x
PG08 -163 35.00
TOTAL: 627.80
TRANSACTION LIST:
Type Method Description Amount
Payment Check 1522 627.80
TOTAL: 627.80
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 26.00
000/345.830 601.80
TOTAL: 627.80
2975 05/29 9711 TOTAL (327.80
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
aeg -(95-1-1
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1t.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360
Project:
1 rQ Vlri
pec
e Ty eof Instio
�' o
Address: Zroa - d u,
Date Called:
Special Instructions:
Date Wanted:
/2-3
p.m.
Requester:
Phone No:
roved per applicable codes. El Corrections required prior to approval.
COMMENTS:
- /Am' (
Inspector: .;ti o
Date: /2. 3 ios
❑ $60.00 REINSPECTION FEE,REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcd'nter Blvd., Sine 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION V2
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
lu7j—1 Fi U/TI
Type of Ins ection:
7( J
Addt s:
6G- /KAG 1,-
Date Called:
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
0 Approved per applicable codes. Corrections required prior to approval.
COMMENTrA
C.* bu,4tt „
Inspect i- /74-/ , „G/UP
Date / j1-/ w.,
❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
Ili3ERMIT COORD COPY 111
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 (0,5L1 DATE: 05 -29 -08
PROJECT NAME: TUTTI FRUTTI FROZEN YOGURT
SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0305
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTME�NT�S � ��'VD
Bu in Di it ion
Public Works
Fire Prevention
Structural
El
Planning Division
❑ Permit Coordinator
Ei
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 06-03-08
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUT NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
DUE DATE: 07-01-08
Approved ❑ Approved with Conditions 11 Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Untitled Page
•
•
Page 1 of 2
Electrical Contractor
A business licensed by LsI to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
J R ELECTRIC INC
Business and Licensing Information
Name J R ELECTRIC INC UBI No. 601896767
Phone 2536308553 Status ACTIVE
Address PO BOX 7900 License No. JRELEI *022QB
Suite /Apt. License Type ELECTRICAL CONTRACTOR
City KENT Effective Date 11 /2/1998
State WA Expiration Date 11/2/2008
Zip 98042 Suspend Date
County KING Separation Date
Business Type CORPORATION Previous License JRELE * *126CJ
Parent Company Next License
Associated License HAGENBE169BZ
Specialty 1 GENERAL
Specialty 2 UNUSED
ADMINISTRATOR INFORMATION
License HAGENBE169BZ
Name HAGEN, BERTHA E
Status ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
HAGEN, JAMES R
01/01/1980
HAGEN, CANDICE L
01/01/1980
MCCULLOCK, JIM
01/01/1980
MICHAEL CHAPMAN INS AGENCY
01/01/1980
Bond Information
I
I
I
https: / /fortress.wa. gov /lni/bbip/Detai 1. aspx ?License= JRELEI* 022QB
07/18/2008
633 SOUTHCENTER, SEATTLE,
WA 98188
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
%���IJ - 4 2008
" City Of Tukwila
1 BUILDING DIVISION
F�L E COPY
Permit N0.
Pier review approval Is subject to errors and omissions.
Approve! of construction documents does not authorize
t le violation of any adopted code or • • 1. = r -. Receipt
o' approv _ d FI -Id Copy and =editions acknowledged:
en
USER: ,...ii,
3
0
0
0
0
0
c
mw
-
0
• 0
m�.
CD1
�a
LL O
~ 8 O
0
0
OI.
0 0
ma
U 0
• -
o
aEL'
CX
5
o E
run
U m
.c
0 0
U
cD
F-N
UC'4
H
L-1,3,5 04
L -15
L -7
L -17
L -18
L!
WASHING
AREA
COUNTER- CASHIER
AREA
L -10,12
li��lali �I�IIIy%
t = =C=:CiCiH
I.1l�
0
C TOMER AREA
ELECTRICAL POWER PLAN
=J I
1
j
4j
SCALE: 1/4" _ 1' -0"
L -11
n
CONSTRUCTION NOTES
0 COORDINATE LOCATION OF THE NEW PANEL L WITH MALL FACIUTIES STAFF. 208/120V 30 4W
PANELBOARD TO HAVE A MINIMUM INTERRUPTING CAPACITY OF 14,000 AMPS.
O COORDINATE POINT OF CONNECTION TO THE 125 -AMP 208/120V 30 4 -WIRE FEED PROVIDED
BY THE MALL CALCULATIONS SHOW THE NEED FOR (3) #1/0 WITH A #6 GROUND IN A 2"
CONDUIT.
0 1/2" CONDUIT TO EXISTING TELEPHONE CABINET, WIRING BY OTHERS.
01/2° CONDUIT (2) #12 WITH (1) #12 GROUND.
01" CONDUIT (3) #4 WITH (1) #B GROUND.
0 JUNCTION BOX MOUNTED INSIDE CASEWORK.
0 220V GFCI RECEPTACLE INSTALLED INSIDE CASEWORK.
NEMA RATING: Fe- 1 r- 3R
SERVICE RATED: r
200% NEUTRAL BUS: i
ISOLATED GND BUS: T
PANEL NAME: L
LOCATION: COORDINATE WITH MALL
MOUNTING: SURFACE
VOLTAGE: 120 /208V 31),4W
A.I.C. RATING: 14,000A
MAIN C.B. SIZE: 125A
BUS SIZE: 125A
1
OUTLETS
1
REC MIS
DESCRIPTION
LOAD (VA)
WATER HEATER WH-1
PHA PH B PH C
8000
C.B.
P A
3
70
3
1
8000
C.B.
A P
20
20
LOAD (VA)
PH A PH B PH C
DESCRIPTION
OUTLETS
2
1250 :+
FROZEN YOGURT MACHINE
C.L C.O. REC MIS
1
2
1250
4
1
8000
20
1250
FROZEN YOGURT MACHINE
1
7
2
RECEPTACLE
360
1
20
20
1250
8
9
2
RECEPTACLE
360 '.
1
20
20
2
FROZEN YOGURT MACHINE
1
10
11
1
REFRIGERATOR
1058
1
20
20
1250
12
13
1
COLD TABLE
862.5
1
20
20
1250
FROZEN YOGURT MACHINE
1
14
15
1
FREEZER
1184.5
1
20
20
1250 `:i: °t' =:_:
16
17
1
MENU SIGN
1200
1
20
20
1
1200
PYLON SIGN I 1
18
19
SPARE
1
20
20
1
SPARE
20
21
23
SPARE
1
20
20
1
SPARE
22
SPARE
1
20
20
1
SPARE
24
25
27
29
SPARE
SPARE
SPARE
1
1
1
20
20
20
20
20
20
1
1
1
SPARE
SPARE
SPARE
26
28
30
31
SPARE
20
20
1
SPARE
32
33
SPARE
1
20
20
1
SPARE
34
35
SPARE
37
39
SPARE
SPARE
1
1
20
20
20
20
1
1
SPARE
SPARE
36
38
1
20
20
1
SPARE
40
41
SPARE
20
20
1
SPARE
REFERENCE NOTES (SEE DESCRIPTION)_
(1) Controlled via lighting control system /panel.
(2) Provide separate neutral for each of these circuits.
(3)
(4)
SUBTOTAL CONNECTED LOAD (VA)
CONTINUOUS LOAD ADDITION (VA)
25% LARGEST MOTOR ADDER (VA)
TOTAL CONNECTED LOAD (VA)
MAXIMUM LINE CURRENT (A)
12,973
13,295
13,958
2,216
296.13
865
15,188
13,591
14,823
126.6
113.3
123.5
TOTAL CONNECTED LOAD:
C.O. DEMAND REDUCTION:
43.6 KVA
0.0 KVA
42
TOTAL DEMAND LOAD: 43.6 KVA
AVERAGE CURRENT: 121.2 A
4
POWER SYMBOLS
SINGLE RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED.
DUPLEX RECEPTACLE, WALL MOUNTED AT +18' A.F.F. OR AS NOTED.
DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED AT +18' A.E.F. OR AS NOTED.
DUPLEX, GFO RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED.
DOUBLE DUPLEX, GFCI RECEPTACLE, WALL MOUNTED AT +18' A.F.F. OR AS NOTED.
DUPLEX RECEPTACLE, BOTTOM HALF SWITCHED, WALL MOUNTED AT +18' A.F.F.
OR AS NOTED.
DEDICATED 20 AMP DUPLEX RECEPTACLE WALL MOUNTED AT +18' A.F.F. OR AS NOTED.
SPECIAL RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED. REFER TO
PLAN NOTES.
SINGLE RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH.
DUPLEX RECEPTACLE, WAIL MOUNTED AT 6" ABOVE COUNTER OR SPLASH.
DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH.
DUPLEX, GFCI RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH.
DOUBLE DUPLEX, GFa RECEPTACLE, WALL MOUNTED AT 6' ABOVE COUNTER OR SPLASH.
DUPLEX RECEPTACLE, BOTTOM HALF SWITCHED, WALL MOUNTED AT 6" ABOVE
COUNTER OR SPLASH.
DEDICATED 20 AMP DUPLEX RECEPTACLE MOUNTED AT 6' ABOVE COUNTER OR SPLASH.
DUPLEX, ISOLATED GROUND RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH.
SPECIAL RECEPTACLE, WALL MOUNTED AT 6' ABOVE COUNTER OR SPLASH.
REFER TO PLAN NOTES.
JUNCTION BOX, WALL MOUNTED AT +18* A.F.F. OR AS NOTED. 4S/DP MINIMUM OR
AS REQUIRED BY N.E.C..
DICTION BOX, MOUNTED IN ACCESSIBLE CEILING FOR APPLICATION DENOTED
ON PLAN. 4S/DP MINIMUM OR AS REQUIRED BY N.EC..
FLUSH MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER. REFER
TO PANEL SCHEDULE
SURFACE MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER. REFER
TO PANEL SCHEDULE.
HID
$a,b
GROUND CONNECTION, SIZE AS INDICATED OR AS REQUIRED.
SINGLE POLE SWITCHES, WALL
INDICATE THE FOLLOWING:
2 - DOUBLE POLE
3 - THREE WAY
4 - FOUR WAY
K - KEY OPERATED
LV - LOW VOLTAGE
MOUNTED AT +48' A.F.F. (MAX). SUBSCRIPTS AT SYMBOL
P - PILOT UGHT
R - REMOTE CONTROL
M - MOTOR STARTING
RL - ROTARY LOCK KEY TYPE
PB - PUSHBUTTON
a, b, c, ETC. - DESIGNATES QUANTITY OF SWITCHES AT EACH LOCATION.
NOTE ALL WALL SWITCHES CONTROLLING EMERGENCY CIRCUITS SHALL BE
ENGRAVED WITH "EMERGENCY"
TELEPHONE /DATA SYMBOLS
TELEPHONE OUTLET BOX, WALL MOUNTED 6" ABOVE COUNTER OR SPLASH. STUB A
3/4' C.O. UP 6" ABOVE THE ACCESSIBLE CEILING AND PROVIDE A BUSHING.
4S/DP MINIMUM WITH SINGLE GANG RING.
DATA OUTLET BOX, WALL MOUNTED 6" ABOVE COUNTER OR SPLASH. STUB A
3/4'C.O. UP 6' ABOVE THE ACCESSIBLE CEILING AND PROVIDE A BUSHING.
4S/DP MINIMUM WITH SINGLE GANG RING.
COMBINATION TELEPHONE AND DATA OUTLET BOX, WALL MOUNTED 6* ABOVE
COUNTER OR SPLASH. STUB A 1" C.O. UP 6' ABOVE THE ACCESSIBLE
CEIUNG AND PROVIDE A BUSHING. 4S /DP MINIMUM WITH SINGLE GANG RING.
BRANCH CIRCUIT SYMBOLS
HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE CIRCUITS.
HASH MARKS INDICATE NUMBER OF CONDUCTORS IN CONDUIT RUN, #12 AVID MINIMUM
UNLESS OTHERWISE NOTED.
HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE
CIRCUITS WITH SEPARATE NEUTRALS. " &" INDICATES SEPARATE NEUTRALS.
A-1+3+5 HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE CIRCUITS,
" +" INDICATES SEPARATE #10 NEUTRAL THROUGHOUT BRANCH CIRCUIT.
HASH MARK " ''INDICATES AN ISOLATED GROUND CONDUCTOR.
CONCEALED BRANCH CIRCUIT UNLESS OTHERWISE NOTED.
CONDUIT RUN CONCEALED BELOW GRADE, 3/(C MINIMUM WITH CODE SIZED
EQUIPMENT GROUND.
TANDEM WIRING CONNECTION. REFER TO TANDEM WIRING DETAIL
CONDUIT STUB OUT, CAP, MARK AND RECORD.
CONDUIT CONTINUATION.
INDICATES FLEXIBLE CONNECTION TO EQUIPMENT. NUMBER OF CONDUCTORS
AS REQUIRED.
2
ELECTRICAL GENERAL NOTES
1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH 2005 (OR LATEST
ADOPTED) NATIONAL ELECTRICAL CODES AND ALL APPLICABLE LOCAL
CODES AND ORDINANCES AS ADOPTED BY THE STATE OF WASHINGTON AND
THE CITY OF TUKWILA, WASHINGTON.
2 BOND AND GROUND ALL EQUIPMENT IN ACCORDANCE WITH 2005 (OR LATEST
ADOPTED) NATIONAL ELECTRICAL CODE
3. ALL WIRING SHALL BE COPPER, 600V WITH THWN /THHN INSULATION,
MINIMUM SIZE SHALL BE #12 UNLESS OTHERWISE NOTED.
4. FIRE PENETRATIONS, PENETRATIONS IN ALL 1 HR. AND 2 HR. WALLS
REQUIRE PROTECTED PENETRATIONS. ALL PENETRATIONS TO BE FIRE
CAULKED WITH AN I.C.B.O. TESTED AND APPROVED ASSEMBLY.
PENETRATIONS AT 1 HR. WALLS SHALL BE APPROVED FOR 1 HR. RATING;
PENETRATIONS AT 2 HR. WALLS SHALL BE APPROVED FOR 2 HR.
RATING. STOPPING SHALL BE AN APPROVED MATERIAL SECURELY
INSTALLED AND CAPABLE OF MAINTAINING ITS INTEGRITY WHEN
SUBJECTED TO TEST TEMPERATURES PRESCRIBED IN U.B.C. STANDARD
NO. 43 -1 FOR THE SPECIFIC WALL OR PARTITION.
OPENINGS IN WALLS AND PARTITIONS SHALL BE PROTECTED. WHEN
ARE --RATED WALL AND PARTITIONS REQUIRE PROTECTED
OPENINGS, THE FOLLOWING PENETRATIONS INTO OR THROUGH
SUCH CONSTRUCTION ARE PERMITTED.
A. COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE THE
WALLS OR PARTITIONS, PROVIDED FIRE STOPPING IS PROVIDED
IN ACCORDANCE WITH THE FIRST OF THIS SECTION.
B. OPENINGS FOR STEEL ELECTRICAL OUTLET BOXES NOT
EXCEEDING 16 SQUARE INCHES OR WALL OR PARTITION
AREA. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR
PARTITIONS SHALL BE SEPARATED BY A HORIZONTAL
DISTANCE OF 24 INCHES.
C. WHEN WALLS ARE PENETRATED BY OTHER MATERIALS OR
WHERE LARGER OPENINGS ARE REQUIRED THAN PERMITTED IN
(B) ABOVE, THEY SHALL BE QUALIFIED BY TESTS CONDUCTED IN
ACCORDANCE WITH THE PROVISIONS OF SECTION 4302 (B).
5. PROVIDE A BOND WIRE IN ALL CONDUITS SIZED IN ACCORDANCE
WITH N.E.C. 250.
6. THE INTENT OF THESE DRAWINGS IS TO DESCRIBE A COMPLETE AND
OPERABLE SYSTEM. BRING ANY QUESTIONS TO THE ENGINEER'S
ATTENTION PRIOR TO BIDDING.
7. PROVIDE GROUNDING WHERE INDICATED OR REQUIRED BY
CODE
8. ALL INSTALLATIONS SHALL MEET FULLY WITH ALL THE REQUIREMENTS
OF THE NATIONAL ELECTRICAL CODE (N.EC.), MATERIAL SHALL BE U.L
LABELED OR LISTED.
9. WHERE NON- METAWC CONDUIT ISSUED, PROVIDE GROUND WIRE.
10. ALL EQUIPMENT, SHALL BE INSTALLED PER MANUFACTURER'S
REQUIREMENTS. PREMISES SHALL BE CLEANED OF DIRT AND DEBRIS.
11. SUBCONTRACT OR SHALL FURNISH FOR APPROVAL SHOP
STARTERS, DRAWINGS OF ELECTRICAL EQUIPMENT, MOTOR
UGHT1NG FIXTURES, AND DEVICES PRIOR TO PURCHASE.
12 FURNISH AND PAY FOR ALL PERMITS, INCLUDING ELECTRICAL UTILITY
CHARGES AND BUILDING DEPARTMENT PERMIT CHARGES.
13. COORDINATE ELECTRICAL WORK WITH REQUIREMENTS OF
OTHER TRADES.
14. THE LOCATIONS OF ANY ELECTRICAL DEVICES INDICATED ON THE
ARCHITECTURAL ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER
THOSE ON THE ELECTRICAL DRAWINGS.
15. ANY DEFICIENCY PERTAINING TO WORKMANSHIP FOUND BY THE
INSPECTOR SHALL BE CORRECTED WITHOUT ADDITIONAL COST TO THE
OWNER.
16.
17. THE ELECTRICAL SUBCONTRACTOR MUST BE LICENSED BY THE STATE
AND MUST VISIT THE JOB SITE PRIOR TO BIDDING, EXAMINE
EXISTING CONDITIONS, AND INCLUDE IN HIS BID ALL LABOR AND
MATERIAL TO INTERFACE WITH OTHER SYSTEMS.
18.
ALL WIRING SHALL BE IN RIGID METAL CONDUIT, OR ELECTRICAL
METALLIC TUBING, 1/2" MINIMUM UNLESS OTHERWISE NOTED.
19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE SUPPORT FOR ALL
ELECTRICAL EQUIPMENT TO COMPLY WITH THE SEISMIC
REQUIREMENTS OF THE UNIFORM BUILDING CODE AND ALL LOCAL
ORDINANCES.
20. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
CONDUITS, WIRES, BOXES, SWITCHES, LIGHTING FIXTURES COMPLETE
WITH LAMPS, AND CONVENIENCE RECEPTACLES, AS INDICATED ON
THE DRAWINGS AND SPECIFICATIONS FOR A COMPLETE AND
OPERATIONAL ELECTRICAL SYSTEM.
21. THE ELECTRICAL CONTRACTOR SHALL NOT BORE, NOTCH OR IN ANY
OTHER WAY CUT INTO STRUCTURAL MEMBERS WITHOUT THE WRITTEN
APPROVAL FROM THE ARCHITECT OR STRUCTURAL ENGINEER.
22. THE ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC IN
NATURE, THE DRAWINGS SHOWS THE APPROXIMATE LOCATIONS OF
THE EQUIPMENT, HOWEVER, IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO INSTALL THE EQUIPMENT AND ASSOCIATED WIRING IN
SUCH A MANNER AS TO CONFORM WITH THE EXISTING STRUCTURE OF
THE BUILDING, AVOID ALL OBSTRUCTIONS AND MEET ALL APPUCABLE
CODE REQUIREMENTS IN THE CITY OF TUKWILA.
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
ROTE: Revisions will require a new plan submittal
and ray include additional plan review fees
SEPARATE PERMIT
REQUIRED FOR:
?Mechanical
0 Electrical
(Plumbing
IVGas Piping
City of Tukwila
BUILDING DIVISION!
TENANT: KEVIN LEE
14545 VALLEY VIEW AV, SUITE B,
SANTA EE SPRINGS, CA 90670
TUTTI RUTTI FROZEN YOGURT
RETAIL
ELECTRICAL
SYBMOLS, NOTES,
ABBREVIATIONS,
& FLOOR PLANS
5CALE: AS NOTED DATE: 05/20/08
RECEIVED
CITY OF TUKWILA
MAY 2 9 2008
PERMIT CENTER
co
0
O
O
0
U
G33 SOUTHCENTER, SEATTLE, WA
et,(*(094