Loading...
HomeMy WebLinkAboutPermit EL08-0654 - WESTFIELD SOUTHCENTER MALL - TUTTI FRUTTI FROZEN YOGURTTUTTI FRUTTI FROZEN YOGURT 2800 SOUTHCENTER MALL K -0305 ELO8-654 Cit3111bf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -654 Issue Date: 07/18/2008 Permit Expires On: 01/14/2009 Tenant: Name: TUTTI FRUTTI FROZEN YOGURT Address: 2800 SOUTHCENTER MALL, K0305 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Phone: 818 402 -8923 Address: 633 SOUTHCENTER MALL, TRAILER 3 , TUKWILA WA Contractor: Name: J R ELECTRIC INC Address: PO BOX 7900 , KENT WA Contractor License No: JRELEI *022QB Phone: 253 630 -8553 Expiration Date: 11/02/2008 DESCRIPTION OF WORK: ALL ELECTRICAL WORK FOR NEW RETAIL KIOSK Value of Electrical: $1,500.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied 'th, Fees Collected: National Electrical Code Edition: $130.00 2005 Date: �� (�) ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or = •e o ce of work. I . authoriiz- to sign and obtain this electrical permit. Signature: Print Name: A/13/", This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: /7 -fr doc: EL -4/07 EL08 -654 Printed: 07 -18 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW TUTTI FRUTTI FROZEN YOGURT Permit Number: Status: Applied Date: Issue Date: EL08 -654 ISSUED 05/29/2008 07/18/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating o truction or the performance of work. Signature: Print Name: 1457 Date: doc: Cond -Elec EL08 -654 Printed: 07 -18 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** TE• LQOATI' a Site Address: K -0305 - South Center Mall Tenant Name: Tutti Frutti Frozen Yogurt Property Owners Name: Westfield Corporation 11601 Wilshire Blvd. Mailing Address: King Co Assessor's Tax No.: 636420 -0010 Suite Number: Floor: 13 New Tenant: ® Yes ❑..No Los Angles City CA state 90025 zip y •;or �+ct^'S x i � yr k'w,' r try • aLl a o do the contact iy eu Tar; rmit.' rW%.'{a,� Name: Marcia Peddicord Mailing Address: 633 South Center - Trailer #3 E -Mail Address: mpeddicord @us.westfield.com Day Telephone: cell: 818- 402 -8923 Tukwila WA 98188 City Fax Number: State Zip Company Name: C&J Technical Solutions and Services, Inc. Mailing Address: 4000 Valley Blvd. Walnut, CA 91789 City - state Zip Contact Person: John Jolly, PE Day Telephone: 909 - 598 -6067 E -Mail Address: Fax Number: 909 - 598 -6089 • Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 1 540 i" (Scope of Work (please provide detailed information): I Lr,- �c�.,,`r ��� � �-,r,: — � t e 1 ► csy hW` -,rk ''-r ne re { I kia Will service be altered? - ❑ Yes ® No Type of Use: Type of work; 2 New ❑ Addition ❑ Service Change 0 Remodel t9 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Adding more than 50 amps? ❑ Yes 'Sv No Property Served by: Puget Sound Energy ❑ Seattle City Light H :IApplicationeiporms-Applientims On Line b1-2007 - Ekcnical Permit Applicadms4oe bh Page 1 of 2 • RESIDENTIAL NEW RESIpENTIAL SERVICE ❑ New single family dwellings 5140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration S75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) S7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PEntrf VrticATio,N ; MULTI- FAMILY AND COMMERCIAL Fees are based on the vahiation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: a�266 / Signature. Date: , ` Print Name: — �f-,�' C/ - C Day Telephone: (' Mailing Address: ' `V ��' j C7 � �,�.�Q�l City Date Application Accepted /, I M I Date Application Expires: 111AppliafuwslFotms- Apptiatines On LineW -7007 - aketrid Permit Appliention.dac Lh State Zip (2i (2 Staff Initials: Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.d.tukwilama.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -654 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/29/2008 Applicant: TUTTI FRUTTI FROZEN YOGURT Issue Date: Receipt No.: R08 -02604 Payment Amount: $104.00 Initials: WER Payment Date: 07/16/2008 10:49 AM User ID: 1655 Balance: $0.00 Payee: KEVIN LEE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1539 104.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 104.00 Total: $104.00 4918 07/16 9710 TOTAL 104.00 doc: Receipt-06 Printed: 07 -16 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //wx w. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -01843 Initials: JEM Payment Date: 05/29/2008 User ID: 1165 Total Payment: 627.80 Payee: KEVIN C. Y. LEE SET ID: S000001036 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -304 566.80 4ci=i 26.00 �' r:x PG08 -163 35.00 TOTAL: 627.80 TRANSACTION LIST: Type Method Description Amount Payment Check 1522 627.80 TOTAL: 627.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 26.00 000/345.830 601.80 TOTAL: 627.80 2975 05/29 9711 TOTAL (327.80 INSPECTION NO. INSPECTION RECORD Retain a copy with permit aeg -(95-1-1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1t. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Project: 1 rQ Vlri pec e Ty eof Instio �' o Address: Zroa - d u, Date Called: Special Instructions: Date Wanted: /2-3 p.m. Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. COMMENTS: - /Am' ( Inspector: .;ti o Date: /2. 3 ios ❑ $60.00 REINSPECTION FEE,REQUIRED. Prior to inspection, fee must be paid at 6300 Southcd'nter Blvd., Sine 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V2 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: lu7j—1 Fi U/TI Type of Ins ection: 7( J Addt s: 6G- /KAG 1,- Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTrA C.* bu,4tt „ Inspect i- /74-/ , „G/UP Date / j1-/ w., ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: Ili3ERMIT COORD COPY 111 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 (0,5L1 DATE: 05 -29 -08 PROJECT NAME: TUTTI FRUTTI FROZEN YOGURT SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0305 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTME�NT�S � ��'VD Bu in Di it ion Public Works Fire Prevention Structural El Planning Division ❑ Permit Coordinator Ei DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-03-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07-01-08 Approved ❑ Approved with Conditions 11 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by LsI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. J R ELECTRIC INC Business and Licensing Information Name J R ELECTRIC INC UBI No. 601896767 Phone 2536308553 Status ACTIVE Address PO BOX 7900 License No. JRELEI *022QB Suite /Apt. License Type ELECTRICAL CONTRACTOR City KENT Effective Date 11 /2/1998 State WA Expiration Date 11/2/2008 Zip 98042 Suspend Date County KING Separation Date Business Type CORPORATION Previous License JRELE * *126CJ Parent Company Next License Associated License HAGENBE169BZ Specialty 1 GENERAL Specialty 2 UNUSED ADMINISTRATOR INFORMATION License HAGENBE169BZ Name HAGEN, BERTHA E Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HAGEN, JAMES R 01/01/1980 HAGEN, CANDICE L 01/01/1980 MCCULLOCK, JIM 01/01/1980 MICHAEL CHAPMAN INS AGENCY 01/01/1980 Bond Information I I I https: / /fortress.wa. gov /lni/bbip/Detai 1. aspx ?License= JRELEI* 022QB 07/18/2008 633 SOUTHCENTER, SEATTLE, WA 98188 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC %���IJ - 4 2008 " City Of Tukwila 1 BUILDING DIVISION F�L E COPY Permit N0. Pier review approval Is subject to errors and omissions. Approve! of construction documents does not authorize t le violation of any adopted code or • • 1. = r -. Receipt o' approv _ d FI -Id Copy and =editions acknowledged: en USER: ,...ii, 3 0 0 0 0 0 c mw - 0 • 0 m�. CD1 �a LL O ~ 8 O 0 0 OI. 0 0 ma U 0 • - o aEL' CX 5 o E run U m .c 0 0 U cD F-N UC'4 H L-1,3,5 04 L -15 L -7 L -17 L -18 L! WASHING AREA COUNTER- CASHIER AREA L -10,12 li��lali �I�IIIy% t = =C=:CiCiH I.1l� 0 C TOMER AREA ELECTRICAL POWER PLAN =J I 1 j 4j SCALE: 1/4" _ 1' -0" L -11 n CONSTRUCTION NOTES 0 COORDINATE LOCATION OF THE NEW PANEL L WITH MALL FACIUTIES STAFF. 208/120V 30 4W PANELBOARD TO HAVE A MINIMUM INTERRUPTING CAPACITY OF 14,000 AMPS. O COORDINATE POINT OF CONNECTION TO THE 125 -AMP 208/120V 30 4 -WIRE FEED PROVIDED BY THE MALL CALCULATIONS SHOW THE NEED FOR (3) #1/0 WITH A #6 GROUND IN A 2" CONDUIT. 0 1/2" CONDUIT TO EXISTING TELEPHONE CABINET, WIRING BY OTHERS. 01/2° CONDUIT (2) #12 WITH (1) #12 GROUND. 01" CONDUIT (3) #4 WITH (1) #B GROUND. 0 JUNCTION BOX MOUNTED INSIDE CASEWORK. 0 220V GFCI RECEPTACLE INSTALLED INSIDE CASEWORK. NEMA RATING: Fe- 1 r- 3R SERVICE RATED: r 200% NEUTRAL BUS: i ISOLATED GND BUS: T PANEL NAME: L LOCATION: COORDINATE WITH MALL MOUNTING: SURFACE VOLTAGE: 120 /208V 31),4W A.I.C. RATING: 14,000A MAIN C.B. SIZE: 125A BUS SIZE: 125A 1 OUTLETS 1 REC MIS DESCRIPTION LOAD (VA) WATER HEATER WH-1 PHA PH B PH C 8000 C.B. P A 3 70 3 1 8000 C.B. A P 20 20 LOAD (VA) PH A PH B PH C DESCRIPTION OUTLETS 2 1250 :+ FROZEN YOGURT MACHINE C.L C.O. REC MIS 1 2 1250 4 1 8000 20 1250 FROZEN YOGURT MACHINE 1 7 2 RECEPTACLE 360 1 20 20 1250 8 9 2 RECEPTACLE 360 '. 1 20 20 2 FROZEN YOGURT MACHINE 1 10 11 1 REFRIGERATOR 1058 1 20 20 1250 12 13 1 COLD TABLE 862.5 1 20 20 1250 FROZEN YOGURT MACHINE 1 14 15 1 FREEZER 1184.5 1 20 20 1250 `:i: °t' =:_: 16 17 1 MENU SIGN 1200 1 20 20 1 1200 PYLON SIGN I 1 18 19 SPARE 1 20 20 1 SPARE 20 21 23 SPARE 1 20 20 1 SPARE 22 SPARE 1 20 20 1 SPARE 24 25 27 29 SPARE SPARE SPARE 1 1 1 20 20 20 20 20 20 1 1 1 SPARE SPARE SPARE 26 28 30 31 SPARE 20 20 1 SPARE 32 33 SPARE 1 20 20 1 SPARE 34 35 SPARE 37 39 SPARE SPARE 1 1 20 20 20 20 1 1 SPARE SPARE 36 38 1 20 20 1 SPARE 40 41 SPARE 20 20 1 SPARE REFERENCE NOTES (SEE DESCRIPTION)_ (1) Controlled via lighting control system /panel. (2) Provide separate neutral for each of these circuits. (3) (4) SUBTOTAL CONNECTED LOAD (VA) CONTINUOUS LOAD ADDITION (VA) 25% LARGEST MOTOR ADDER (VA) TOTAL CONNECTED LOAD (VA) MAXIMUM LINE CURRENT (A) 12,973 13,295 13,958 2,216 296.13 865 15,188 13,591 14,823 126.6 113.3 123.5 TOTAL CONNECTED LOAD: C.O. DEMAND REDUCTION: 43.6 KVA 0.0 KVA 42 TOTAL DEMAND LOAD: 43.6 KVA AVERAGE CURRENT: 121.2 A 4 POWER SYMBOLS SINGLE RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED. DUPLEX RECEPTACLE, WALL MOUNTED AT +18' A.F.F. OR AS NOTED. DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED AT +18' A.E.F. OR AS NOTED. DUPLEX, GFO RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED. DOUBLE DUPLEX, GFCI RECEPTACLE, WALL MOUNTED AT +18' A.F.F. OR AS NOTED. DUPLEX RECEPTACLE, BOTTOM HALF SWITCHED, WALL MOUNTED AT +18' A.F.F. OR AS NOTED. DEDICATED 20 AMP DUPLEX RECEPTACLE WALL MOUNTED AT +18' A.F.F. OR AS NOTED. SPECIAL RECEPTACLE, WALL MOUNTED AT +18" A.F.F. OR AS NOTED. REFER TO PLAN NOTES. SINGLE RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. DUPLEX RECEPTACLE, WAIL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. DUPLEX, GFCI RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. DOUBLE DUPLEX, GFa RECEPTACLE, WALL MOUNTED AT 6' ABOVE COUNTER OR SPLASH. DUPLEX RECEPTACLE, BOTTOM HALF SWITCHED, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. DEDICATED 20 AMP DUPLEX RECEPTACLE MOUNTED AT 6' ABOVE COUNTER OR SPLASH. DUPLEX, ISOLATED GROUND RECEPTACLE, WALL MOUNTED AT 6" ABOVE COUNTER OR SPLASH. SPECIAL RECEPTACLE, WALL MOUNTED AT 6' ABOVE COUNTER OR SPLASH. REFER TO PLAN NOTES. JUNCTION BOX, WALL MOUNTED AT +18* A.F.F. OR AS NOTED. 4S/DP MINIMUM OR AS REQUIRED BY N.E.C.. DICTION BOX, MOUNTED IN ACCESSIBLE CEILING FOR APPLICATION DENOTED ON PLAN. 4S/DP MINIMUM OR AS REQUIRED BY N.EC.. FLUSH MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER. REFER TO PANEL SCHEDULE SURFACE MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER. REFER TO PANEL SCHEDULE. HID $a,b GROUND CONNECTION, SIZE AS INDICATED OR AS REQUIRED. SINGLE POLE SWITCHES, WALL INDICATE THE FOLLOWING: 2 - DOUBLE POLE 3 - THREE WAY 4 - FOUR WAY K - KEY OPERATED LV - LOW VOLTAGE MOUNTED AT +48' A.F.F. (MAX). SUBSCRIPTS AT SYMBOL P - PILOT UGHT R - REMOTE CONTROL M - MOTOR STARTING RL - ROTARY LOCK KEY TYPE PB - PUSHBUTTON a, b, c, ETC. - DESIGNATES QUANTITY OF SWITCHES AT EACH LOCATION. NOTE ALL WALL SWITCHES CONTROLLING EMERGENCY CIRCUITS SHALL BE ENGRAVED WITH "EMERGENCY" TELEPHONE /DATA SYMBOLS TELEPHONE OUTLET BOX, WALL MOUNTED 6" ABOVE COUNTER OR SPLASH. STUB A 3/4' C.O. UP 6" ABOVE THE ACCESSIBLE CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. DATA OUTLET BOX, WALL MOUNTED 6" ABOVE COUNTER OR SPLASH. STUB A 3/4'C.O. UP 6' ABOVE THE ACCESSIBLE CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. COMBINATION TELEPHONE AND DATA OUTLET BOX, WALL MOUNTED 6* ABOVE COUNTER OR SPLASH. STUB A 1" C.O. UP 6' ABOVE THE ACCESSIBLE CEIUNG AND PROVIDE A BUSHING. 4S /DP MINIMUM WITH SINGLE GANG RING. BRANCH CIRCUIT SYMBOLS HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE CIRCUITS. HASH MARKS INDICATE NUMBER OF CONDUCTORS IN CONDUIT RUN, #12 AVID MINIMUM UNLESS OTHERWISE NOTED. HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE CIRCUITS WITH SEPARATE NEUTRALS. " &" INDICATES SEPARATE NEUTRALS. A-1+3+5 HOME RUN TO PANEL LETTER DESIGNATES PANEL, NUMBERS INDICATE CIRCUITS, " +" INDICATES SEPARATE #10 NEUTRAL THROUGHOUT BRANCH CIRCUIT. HASH MARK " ''INDICATES AN ISOLATED GROUND CONDUCTOR. CONCEALED BRANCH CIRCUIT UNLESS OTHERWISE NOTED. CONDUIT RUN CONCEALED BELOW GRADE, 3/(C MINIMUM WITH CODE SIZED EQUIPMENT GROUND. TANDEM WIRING CONNECTION. REFER TO TANDEM WIRING DETAIL CONDUIT STUB OUT, CAP, MARK AND RECORD. CONDUIT CONTINUATION. INDICATES FLEXIBLE CONNECTION TO EQUIPMENT. NUMBER OF CONDUCTORS AS REQUIRED. 2 ELECTRICAL GENERAL NOTES 1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH 2005 (OR LATEST ADOPTED) NATIONAL ELECTRICAL CODES AND ALL APPLICABLE LOCAL CODES AND ORDINANCES AS ADOPTED BY THE STATE OF WASHINGTON AND THE CITY OF TUKWILA, WASHINGTON. 2 BOND AND GROUND ALL EQUIPMENT IN ACCORDANCE WITH 2005 (OR LATEST ADOPTED) NATIONAL ELECTRICAL CODE 3. ALL WIRING SHALL BE COPPER, 600V WITH THWN /THHN INSULATION, MINIMUM SIZE SHALL BE #12 UNLESS OTHERWISE NOTED. 4. FIRE PENETRATIONS, PENETRATIONS IN ALL 1 HR. AND 2 HR. WALLS REQUIRE PROTECTED PENETRATIONS. ALL PENETRATIONS TO BE FIRE CAULKED WITH AN I.C.B.O. TESTED AND APPROVED ASSEMBLY. PENETRATIONS AT 1 HR. WALLS SHALL BE APPROVED FOR 1 HR. RATING; PENETRATIONS AT 2 HR. WALLS SHALL BE APPROVED FOR 2 HR. RATING. STOPPING SHALL BE AN APPROVED MATERIAL SECURELY INSTALLED AND CAPABLE OF MAINTAINING ITS INTEGRITY WHEN SUBJECTED TO TEST TEMPERATURES PRESCRIBED IN U.B.C. STANDARD NO. 43 -1 FOR THE SPECIFIC WALL OR PARTITION. OPENINGS IN WALLS AND PARTITIONS SHALL BE PROTECTED. WHEN ARE --RATED WALL AND PARTITIONS REQUIRE PROTECTED OPENINGS, THE FOLLOWING PENETRATIONS INTO OR THROUGH SUCH CONSTRUCTION ARE PERMITTED. A. COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE THE WALLS OR PARTITIONS, PROVIDED FIRE STOPPING IS PROVIDED IN ACCORDANCE WITH THE FIRST OF THIS SECTION. B. OPENINGS FOR STEEL ELECTRICAL OUTLET BOXES NOT EXCEEDING 16 SQUARE INCHES OR WALL OR PARTITION AREA. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES. C. WHEN WALLS ARE PENETRATED BY OTHER MATERIALS OR WHERE LARGER OPENINGS ARE REQUIRED THAN PERMITTED IN (B) ABOVE, THEY SHALL BE QUALIFIED BY TESTS CONDUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 4302 (B). 5. PROVIDE A BOND WIRE IN ALL CONDUITS SIZED IN ACCORDANCE WITH N.E.C. 250. 6. THE INTENT OF THESE DRAWINGS IS TO DESCRIBE A COMPLETE AND OPERABLE SYSTEM. BRING ANY QUESTIONS TO THE ENGINEER'S ATTENTION PRIOR TO BIDDING. 7. PROVIDE GROUNDING WHERE INDICATED OR REQUIRED BY CODE 8. ALL INSTALLATIONS SHALL MEET FULLY WITH ALL THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (N.EC.), MATERIAL SHALL BE U.L LABELED OR LISTED. 9. WHERE NON- METAWC CONDUIT ISSUED, PROVIDE GROUND WIRE. 10. ALL EQUIPMENT, SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS. PREMISES SHALL BE CLEANED OF DIRT AND DEBRIS. 11. SUBCONTRACT OR SHALL FURNISH FOR APPROVAL SHOP STARTERS, DRAWINGS OF ELECTRICAL EQUIPMENT, MOTOR UGHT1NG FIXTURES, AND DEVICES PRIOR TO PURCHASE. 12 FURNISH AND PAY FOR ALL PERMITS, INCLUDING ELECTRICAL UTILITY CHARGES AND BUILDING DEPARTMENT PERMIT CHARGES. 13. COORDINATE ELECTRICAL WORK WITH REQUIREMENTS OF OTHER TRADES. 14. THE LOCATIONS OF ANY ELECTRICAL DEVICES INDICATED ON THE ARCHITECTURAL ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER THOSE ON THE ELECTRICAL DRAWINGS. 15. ANY DEFICIENCY PERTAINING TO WORKMANSHIP FOUND BY THE INSPECTOR SHALL BE CORRECTED WITHOUT ADDITIONAL COST TO THE OWNER. 16. 17. THE ELECTRICAL SUBCONTRACTOR MUST BE LICENSED BY THE STATE AND MUST VISIT THE JOB SITE PRIOR TO BIDDING, EXAMINE EXISTING CONDITIONS, AND INCLUDE IN HIS BID ALL LABOR AND MATERIAL TO INTERFACE WITH OTHER SYSTEMS. 18. ALL WIRING SHALL BE IN RIGID METAL CONDUIT, OR ELECTRICAL METALLIC TUBING, 1/2" MINIMUM UNLESS OTHERWISE NOTED. 19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE SUPPORT FOR ALL ELECTRICAL EQUIPMENT TO COMPLY WITH THE SEISMIC REQUIREMENTS OF THE UNIFORM BUILDING CODE AND ALL LOCAL ORDINANCES. 20. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS, WIRES, BOXES, SWITCHES, LIGHTING FIXTURES COMPLETE WITH LAMPS, AND CONVENIENCE RECEPTACLES, AS INDICATED ON THE DRAWINGS AND SPECIFICATIONS FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. 21. THE ELECTRICAL CONTRACTOR SHALL NOT BORE, NOTCH OR IN ANY OTHER WAY CUT INTO STRUCTURAL MEMBERS WITHOUT THE WRITTEN APPROVAL FROM THE ARCHITECT OR STRUCTURAL ENGINEER. 22. THE ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC IN NATURE, THE DRAWINGS SHOWS THE APPROXIMATE LOCATIONS OF THE EQUIPMENT, HOWEVER, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL THE EQUIPMENT AND ASSOCIATED WIRING IN SUCH A MANNER AS TO CONFORM WITH THE EXISTING STRUCTURE OF THE BUILDING, AVOID ALL OBSTRUCTIONS AND MEET ALL APPUCABLE CODE REQUIREMENTS IN THE CITY OF TUKWILA. City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ROTE: Revisions will require a new plan submittal and ray include additional plan review fees SEPARATE PERMIT REQUIRED FOR: ?Mechanical 0 Electrical (Plumbing IVGas Piping City of Tukwila BUILDING DIVISION! TENANT: KEVIN LEE 14545 VALLEY VIEW AV, SUITE B, SANTA EE SPRINGS, CA 90670 TUTTI RUTTI FROZEN YOGURT RETAIL ELECTRICAL SYBMOLS, NOTES, ABBREVIATIONS, & FLOOR PLANS 5CALE: AS NOTED DATE: 05/20/08 RECEIVED CITY OF TUKWILA MAY 2 9 2008 PERMIT CENTER co 0 O O 0 U G33 SOUTHCENTER, SEATTLE, WA et,(*(094