ELECTRICAL PERMIT
Parcel No.: 6364200010
Address: 2800 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: EL08 -693
Issue Date: 07/17/2008
Permit Expires On: 01/13/2009
Tenant:
Name: CINNABON
Address: 2800 SOUTHCENTER MALL, K -2628 , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: GREG KOMAN Phone: 425 455 -4200
Address: 9 103 AV NE , BELLEVUE WA
Contractor:
Name: KIRBY ELECTRIC INC Phone: 253 859 -2000
Address: 4826 B ST NW, STE 101 , AUBURN WA
Contractor License No: KIRBYEI077BN Expiration Date: 01/13/2009
DESCRIPTION OF WORK:
ALL ELECTRICAL MATERIAL AND SUPPLIES FOR NEW KIOSK
Value of Electrical: $7,000.00
Fees Collected:
$246.00
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
ex•
•wi
Date: U'l l n
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this electrical permit.
Signature:
Print Name: %% -
Date:
/a'
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -693 Printed: 07 -17 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 6364200010
Address: 2800 SOUTHCENTER MALL TUKW
Suite No:
Tenant: CINNABON
Permit Number: E]L08 -693
Status: ISSUED
Applied Date: 06/05/2008
Issue Date: 07/17/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature:
Print Name: �r . ci.'—' -- ed4
Date: ? /97
doc: Cond -Elec
EL08 -693 Printed: 07 -17 -2008
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
•
Electrical Permit No. 61/1?
Project No.
f'00 - 117o
(For office icse only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
/� C King Co Assessor's Tax No.: 634 q2/ -,a do 11,
Site Address: ' `'Z . /f Se j IC e_, �c.' f ir' J/ Suite Number: Floor: c
Tenant Name: C�Irh !7 R 4.211e1 New Tenant: ga"---Yes ❑ .. No
Property Owners Name: /24'0 T' 4' e (4 4 ,
Mailing Address: Nei/ &,t/6Jiil,e 73414.. / /1t'2/ LE254 e..3 — 9.60.2S
City State Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: G r
eprn.tu,
Mailing Address:" /034 , L
E -Mail Address: 1/Gfl7 e 1 16)i77 , toart
ELECTRICAL CONTRACTOR INFORMATION
Day Telephone: 7"ca.5- <ASS- 424D
?Se /lel) ue_
City //`
Fax Number: 425 • ASS - 457)
A- 98'aa1Z
State Zip
Company Name: 7 S D
Mailing Address:
city State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $ 7i�
Scope of Work (please provide detailed information): 14 /1 e / A.71el`-��i 7
SZtp i PS Ar"V h
Will service be altered? ❑ Yes 111---No Adding more than 50 amps? ❑ Yes Q-i
Type of Use:
Type of work:
[j 4(ew ❑ Addition ❑ Service Change ❑ Remodel -T nant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served bv:
E/(fuget Sound Energy
❑ Seattle City Light
H.. \ppltcahons,Forms- Apphcanens t)n Lme4 -2l10' - F.lecmcal Permu Apphcation.doe
ah
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings 5140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings 575.00 ea
❑ Low voltage systems
(alarm. furnace thermostat) S55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration 575.00
(no added/altered circuits)
❑ Service change with added /altered circuits 575.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change 550.00
(up to 5 circuits)
❑ Circuits added/altered without service change 550.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm. furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) 558.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service 580.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: m /We/ IG49 Zc,
Mailing Address: l ' 3 Se,LIMt
IDate Application Accepted: ae ,( m Date Application Expires:
H: Wpplicannns.Fnnns -Apnli anon On LkneJ -21117 - Glennwl Per ApnlIcanon tine
bh
Date:
Day Telephone: iG — g4 2-- ‘en?
-77i kip: /4
City State Zip
9s)-/ 2-V
Staff Initials:
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -693
Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 06/05/2008
Applicant: CINNABON Issue Date:
Receipt No.: R08 -02610
Initials: JEM
User ID: 1165
Payment Amount: $.30
Payment Date: 07/16/2008 12:38 PM
Balance: $0.00
Payee: CINNABON - MF SOUTHCENTER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash .30
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 .30
Total: $.30
4903 07/16 9710 TOTAL 0.30
doe.: RAC.e.int -OR
Printprl. 07- 16-2nnR
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -693
Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 06/05/2008
Applicant: CINNABON Issue Date:
Receipt No.: R08 -02609
Initials: JEM
User ID: 1165
Payment Amount: $196.50
Payment Date: 07/16/2008 12:36 PM
Balance: $0.30
Payee: CINNABON - MF SOUTHCENTER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 10 196.50
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 196.50
Total: $196.50
4910 07/16 9710 TOTAL 196.50
(Inn. Rac int -(1R Printpri- (17- 16-2Of1R
INSPECTION RECORD _6q,3
Retain a copy with permit f
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION �'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7
Project: ei I1441c 13
Type of Inspection:
?A0°
Address: n ■ M
Date Called:
Special Instructions:
1
Date Wanted:
17 f
y{
a.m
m.
Requester:
Phone No:
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
Inspector: A."�
(Date: a1 J2 q&r
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
X473
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3470
INSPECTION NO.
Project: if
Type of Inspection: Too
Address: 4. 2(412'
11/40 _ ,
Date Called:
Special Instructions:
Date Wanted:
7/2 '5
a.m
P.m .
Requester:
Phone No:
Approved per applicable codes. DI Corrections required prior to approval.
C • MENTS:
Inspector: _ foil exAwcr,,N
'Date: D1 14,18,
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http.• //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R08 -01967
Initials: JEM
User ID: 1165
Payee: M.F.S. MANAGEMENT CO.
Payment Date: 06/05/2008
Total Payment: 648.00
SET ID: S000001044 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -315 566.80
.171171E76731° 49.20
PG08 -169 32.00
TOTAL: 648.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3077 648.00
TOTAL: 648.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 49.20
000/345.830 598.80
TOTAL: 648.00
3342 06/06 0711 TOTAL 648.00
» PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -693 DATE: 06 -05 -08
PROJECT NAME: CI N NABON
SITE ADDRESS: 2800 SOUTHCENTER MALL, K -2628
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS: (k it
Bui ng ivision
n
Public Works
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
n
0
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 06-10-08
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 07-08-08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Untitled Page
•
Page 1 of 2
Electrical Contractor
A business licensed by L£tI to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
KIRBY ELECTRIC INC
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
KIRBY ELECTRIC INC
2538592000
4826 B ST NW STE 101
AUBURN
WA
98001
KING
CORPORATION
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Separation Date
Previous License KIRBYE *101QE
Next License
Associated License KIRBYDE962LZ
Specialty 1 GENERAL
Specialty 2 UNUSED
601433048
ACTIVE
KIRBYEI077BN
ELECTRICAL CONTRACTOR
1/15/1993
1/13/2009
MASTER ELECTRICIAN INFORMATION
License KIRBYDE962LZ
Name KIRBY, DOUGLAS E
Status ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
KIRBY, DOUGLAS E
Cancel
Date
01/01/1980
Bond
Amount
KIRBY, SHANNON
4
01/01/1980
WA 12415
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
4
MERCHANTS
BONDING CO
(MUTUAL)
WA 12415
01/14/2005
Until
Cancelled
$4,000.0011
/04/2004
https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= KIRBYEI077BN
07/17/2008
J:1IBT Camel- Cinnabon108064 Tukwillal060e1.0.dwg, 5/8/2008 4:54:35 PM, vaughn, 1:24
MALL SWITCHBOARD
(FIELD VERIFY) -
MALL ELECTRIC ROOM
TENANT REMOTE STORAGE AREA
MALL SWITCHBOARD
(FIELD VERIFY) -\
MALL ELECTRIC ROOM
TENANT KIOSK
METER BY
UTILITY
COMPANY
METER BY
UTILITY
COMPANY
NOTE: CONDUIT & WIRING IS FURNISHED
AND INSTALLED BY LANDLORD. 4#6,
#10 GRD, 11/4 "C (MINIMUM)
V.D. NOT TO EXCEED 2%
NOTE CONDUIT & WIRING IS FURNISHED
AND INSTALLED BY LANDLORD. 4#3/0,
#6 GRD, 21/2 "C (MINIMUM)
V.D. NOT TO EXCEED 2%,
EXIST.
40A /3P
CKT
BREAKER
NEW
PANEL
"B"
40A M.B.
120/208V 30
r -i
1 1 I 1 1 1, 11
EXIST.
200A/3P
CKT
BREAKER
LANDLORD CONTACT
JOSH KIMMEL
11601 WILSHIRE BLVD, 9TH FLOOR
LOS ANGELES, CA 90025
JKIMMEL @WESTFIELD.COM
PHONE: 310 - 893 -4761
POWER PLAN KEYED NOTES o
01 NEW PANEL "A ". SEE PANELBOARD SCHEDULE, THIS SHEET, FOR MORE
INFORMATION.
0 WALL RECEPTACLE IS PROVIDED w /EQUIPMENT.
V J -BOX FOR CONNECTION TO WATER HEATER. COORDINATE LOCATION
w /PLUMBING CONTRACTOR.
@ PROVIDE NEMA 6 -50R RECEPTACLE.
®5 E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUIT AS REQUIRED
BY N.EC. 600. CONTROLLED BY TIME CLOCK.
06 TELEPHONE WORK SHALL BE ARRANGED WITH THE TELEPHONE COMPANY BY
TENANT AT TENANTS EXPENSE. PROVIDE 3/4" PLYWOOD BACKBOARD FOR
MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUPMENT. SIZE AND
SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR
POWER TO TELEPHONE EQUIPMENT. COORDINATE EXACT LOCATION PRIOR TO
INSTALLATION.
NO SCALE
NO SCALE
A- 18,20,22
COORDINATE LOCATION PE PANEL WITH
PLUMBING VENT AND WASTE= LINES,
PANEL FACES TOWARDS: MALL `\\
11
III A -7 A -' - '•
III piii r:mp a irmi:: 0..
rmr-Afi
!U _ill_
42 POSITION, CABINET MOUNTED
VOLTAGE 120/208V 3 04W
NEW PANEL
200 AMP MAIN BREAKER
COORDINATE AIC REQUIREMENTS W/ POWER COMPANY
& LANDLORD
0
r -i
1 1 I 1 1 1, 11
EXIST.
200A/3P
CKT
BREAKER
LANDLORD CONTACT
JOSH KIMMEL
11601 WILSHIRE BLVD, 9TH FLOOR
LOS ANGELES, CA 90025
JKIMMEL @WESTFIELD.COM
PHONE: 310 - 893 -4761
POWER PLAN KEYED NOTES o
01 NEW PANEL "A ". SEE PANELBOARD SCHEDULE, THIS SHEET, FOR MORE
INFORMATION.
0 WALL RECEPTACLE IS PROVIDED w /EQUIPMENT.
V J -BOX FOR CONNECTION TO WATER HEATER. COORDINATE LOCATION
w /PLUMBING CONTRACTOR.
@ PROVIDE NEMA 6 -50R RECEPTACLE.
®5 E.C. SHALL INSTALL DISCONNECT SWITCH FOR SIGNAGE CIRCUIT AS REQUIRED
BY N.EC. 600. CONTROLLED BY TIME CLOCK.
06 TELEPHONE WORK SHALL BE ARRANGED WITH THE TELEPHONE COMPANY BY
TENANT AT TENANTS EXPENSE. PROVIDE 3/4" PLYWOOD BACKBOARD FOR
MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUPMENT. SIZE AND
SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR
POWER TO TELEPHONE EQUIPMENT. COORDINATE EXACT LOCATION PRIOR TO
INSTALLATION.
NO SCALE
NO SCALE
A- 18,20,22
COORDINATE LOCATION PE PANEL WITH
PLUMBING VENT AND WASTE= LINES,
PANEL FACES TOWARDS: MALL `\\
11
III A -7 A -' - '•
III piii r:mp a irmi:: 0..
rmr-Afi
!U _ill_
42 POSITION, CABINET MOUNTED
VOLTAGE 120/208V 3 04W
NEW PANEL
200 AMP MAIN BREAKER
COORDINATE AIC REQUIREMENTS W/ POWER COMPANY
& LANDLORD
WIRE z LOAD WATTS z WIRE CB
CB & LOAD SERVED c o o c, LOAD SERVED COND.
0 COND. w 0- s A OB s C w
1 20/1 12, 3/4 REACH -IN FREEZER J20 1 240 r 2 860-07 SODA DISPENSER 12, 3/4 20/1 2
3 20/1 12, 3/4 MICROWAVE OVEN 815 3 / 840' 4 B60-05 CARBONATOR 12, 3/4 20/1 4
5 20/1 12, 3/4 HEATED HOLDING SHELF B40-36 5 1560 720 6 866 -01 MOCHALATTA DISPENSER 12, 3/4 20/1 6
7 20/1 12, 3/4 BLENDER B68 7 500 1560 8 SPARE 20/1 8
9 20/1 12, 3/4 BLENDER B68 9 3016 10 314 UNDERCOUNTER REFRIG. 12, 3/4 20/1 10
11 40 8, 3/4 COFFEE BREWER C21 -01 11 3016 840 1632 12 J60 -01 ICE MAKER 12, 3/4 20/1 12
13 � 13 �0 14 LTG CONTACTOR / TIME CLOCK 12, 3/4 20/1 14
15 20/1 12, 3/4 CASH REGISTERS (10) I70 -01 15 240 16 CONVENIENCE RECEPTACLE 12 3/4 20/1 16
17 20/1 12, 3/4 CONVENIENCE RECEPTACLES 17 6000 180 3872 18 610 CONVECTION OVEN 8, 1 40 18
19 70 4, 1 1 /4 WATER HEATER c1 19 3872 6000 20 20
21 21 3872 6000 22 3 22
23 3 23 1200 1000 24 SPARE 20/1 24
25 20/1 12, 3/4 CINNABON SIGN L11 -01 25 200 f' 1200 26 TELEPHONE RECEPTACLE 12, 3/4 20/1 26
27 20/1 12, 3/4 • CINNABON SIGN L11 -01 27 1000 1000 28 SPARE 20/1 28
29 20/1 SPARE 29 1000 30 SPARE 20/1 30
31 SPACE 31 0 32 SPACE 32
33 SPACE 33 0 00 34 34
35 SPACE 35 36 36
37 37 0 0 0 38 38
39 39 0 + 0 40 40
41 41 0 42 42
NOTES:
Qt VERIFY W/ P.C.
IG ISOLATED CIRCUIT & ISOLATED GROUND WIRE
TOTAL: I 17908 17292 19020
PANEL LOAD ANALYSIS "A"
SYMBOL LEGEND
cb SINGLE RECEPTACLE
db DUPLEX RECEPTACLE
QUADPLEX RECEPTACLE
® SPECIAL VOLTAGE OR AMPERAGE
• TELEPHONE OUTLET
JQ JUNCTION BOX
ELECTRICAL PANEL
7 DAY 24 HOUR TIME CLOCK AND ELECTRICALLY HELD LIGHTING CONTACTOR
FOR CONTROL OF SIGNAGE.
NEW PANEL BOARD. PROVIDE WORKING CLEARANCES PER N.E.C.
CONDENSING UNIT MOUNTED ON TOP OF WALK -IN BOX, PROVIDE DISCONNECT
AS REQUIRED TO TERMINATE POWER.
10 CIRCUITS USED TO POWER THE ELECTRONIC REGISTERS AND COMPUTERS
SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE
NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL
AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO
THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO
THE GROUND TERMINAL ISOLATED FROM NEUTRAL DO NOT USE CONDUIT FOR
GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES. CASH
REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES
SHALL BE HUBBELL #IG -5362.
11 120V, 10, 20A CIRCUIT, 660 WATTS FOR REACH -IN REFRIGERATOR.
12 120V, 10, 20A CIRCUIT, FOR FREEZER DOOR HEATER & LTS.
13 208V, 30, 4 WIRE, 100A DISCONNECT FOR WATER HEATER. VERIFY
REQUIREMENTS W/ MANUFACTURER & INSPECTOR.
O. ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT WITH PULLWIRE FROM
CASH /WRAP TO TELEPHONE BACKBOARD.
O. 208V, 10, 20A CIRCUIT, 3.8 KW FOR FREEZER REFRIGERATION.
16 LIGHTING IS FURNISHED BY LANDLORD AS COMMON TO THIS AREA.
TOTAL CONNECTED LOAD: 54,220 WATTS
LIGHTS
KITCHEN
MISC. /SPARES
FANS
WTR HTR
TOTAL
2.4
30.1
3.7
10 0 100%
REMAIN ER x 5@%
3.0
19.6
3.7
18.00
54.2
18.00
44.3
123.0A
ELECTRICAL POWER PLAN
SCALE: 1/2' = 1' -0 "'
REVISIONS
No changes shall be made to thP scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FIE COPY
Permit No. kweddi
Dl�.r review approval is subject to errors omissions.
I,ppra�ra" of construction d� �. authorize
the violation of any adopted Receipt
approved Field Copy and �s Is ��:
By
Date:
City of Tukwila
BULL DING DIVISION
REMOTE STORAGE POWER PLAN
SCALE 1/2" = 1' -r
12 POSITION, SURFACE MOUNTED
NEW PANEL
VOLTAGE 120/208V 3 04W
40 AMP MAIN BREAKER
COORDINATE AIC REQUIREMENTS W/ POWER COMPANY
& LANDLORD
o o
CB &RE LOAD SERVED c LOAD WATTS 1-L11 c LOAD SERVED WIRE CB
ca COND. w a � A OB OC w COND. ca
1 30 10, 3/4 FREEZER CONDENSING UNIT A40.03 1 0 1882 2 SPACE - 2
1882
3 2 3 0 192 4 SPACE - 4
5 20/1 12, 3/4 FREEZER LIGHTS/ DOOR A40.05 5 0 6 SPACE - 6
7 20/1 12, 3/4 REACH -IN REFRIG. J10 7 660 8 SPACE - 8
9 20/1 12, 3/4 CONY. OUTLETS 9 i 060 1000 10 SPACE - 10
11 20/1 SPARE 11 0 12 SPACE - 12
NOTES:
QVERIFY W/ P.C.
IG ISOLATED CIRCUIT & ISOLATED GROUND WIRE
TOTAL CONNECTED LOAD: 5,976 WATTS
ITEM
LIGHTS
KITCHEN
MISC. /SPARES
FANS
TOTAL
LOAD (Kw)
DIVERSITY
125%
100%
10 0 106X
100%
DEMAND (Kw)
16.7A
J1 0
F EQUIPMENT SCHEDULE - ELECTRICAL
2 ELECTRICAL
DESCRIPTION MANUFACTURER MODEL - - REMARKS
o FURNISH INSTALL AMP KW HP VOLT PH CONN HGT.
B10 -208 CONVECTION OVEN (SINGLE DECK) LANG ECCO- LMDR480 /60101 -68KIT EQ. SUPP. GC 32.24 208 3 PLUG 18" NOTE #3
B15 MICROWAVE OVEN AMANA LD1OMP EQ. SUPP. GC 13 120 1 PLUG 24"
B40 -36 HEATED HOLDING SHELF HATCO GRS-36 EQ. SUPP. GC 4.6 120 1 PLUG 18"
COCA COLA OWNER OWNER 7 1/3 , 120 1 PLUG 72"
860 -07 SODA pTPENSER LANCER COLA
866 -01 MOCHA
LATTA DISPENSER CRATHCO D25-4CB (3 GAL BOWL) EQ OWNER SUPP. OWNER GC B 1 /5 115....1 PLUG. 24 "... #
15 1 PLUG 24 NOTE 1.........
B68 BLENDER BLENDTEC ICB -3 SMOOTHER 13 EQ. SUPP. GC 13 120. 1 PLUG 24"
C21 -01 COFFEE BREWER . .. ... BUNN-O-MATIC . CWTF35-APS EQ. SUPP. GC 29 208 1 PLUG 42" NOTE #4
J14 REACH-IN REFRIGERATOR R RE RAT VICTORY RA- 1D--S7 EQ. SUPP. GC 5.5 1/3 120 1 PLUG , 18" NOTE #1
OR VICTORY UR -4 -SST EQ. SUPP. GC 7 1/5 115 1 PLUG 18" NOTE #1
J20........ REACH -IN FREEZER VICTORY FA -ID -S7 EQ. SUPP. GC 8.5 1/3 115 1 PLUG 18" NOTE #1...._.._.. ........
J70 --01 CASH REGISTER SEE OWNER SEE OWNER OWNER GC 2.0 115 , 1 PLUG 24" NOTE #2
J60 -01 ICE MAKER MANITOWAC SY-0424A EQ. SUPP. GC 13.6 115 1 30"
L11 -01 CINNABON SIGN CINNABQN SIGN VENDOR CINNABON SIGN VENDOR CINN. S.V. GC VERIFY 120 1 DIRECT AS REQ'D
A40.03 FREEZER MASTER BILT CL- 156 -200 EQ SUPP. GC 1.6/1 8.1 2.0
115/208 1 DIRECT NOTE #5
NOTE #1: PROVIDE HACK TYPE CIRCUIT BREAKER.
NOTE #2: E.C. TO INSTALL (1) I.G. DUPLEX, (1) GENERAL DUPLEX, AND (1) TELEPHONE OUTLET FOR EACH REGISTER LOCATION.
NOTE #3: WALL RECEPTACLE PROVIDED W/ EQUIPMENT.
NOTE #4: 3 WIRES PLUS GROUND REQUIRED.
NOTE #5: HARD WIRED W/ SEPERATE JUNCTION BOXES FOR 115V & 208 -230V, VERIFY W/ MFG.
GENERAL ELECTRICAL NOTES
1. THE G.C. IS RESPONSIBLE FOR ALL TEMPORARY POWER AS NECESSARY.
2. COORDINATE ALL ELECTRICAL INSTALLATION RESPONSIBILITIES w /OWNER IN FIELD PRIOR TO BID.
3. THE G.C. IS RESPONSIBLE FOR ALL FLOOR AND WALL PENETRATIONS FOR ELECTRICAL AND MECHANICAL
WORK. ALL SUCH OPENINGS SHALL BE FRAMED AND REINFORCED. NO PENETRATIONS SHALL BE CUT
WITHOUT PRIOR AUTHORIZATION BY THE LANDLORD.
4. G.C. TO VERIFY AND RECEIVE APPROVAL FROM MALL MANAGEMENT PRIOR TO TRENCHING.
5. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL EQUIPMENT NEUTRAL AND GROUND WIRING AS
REQUIRED.
6. THE EQUIPMENT ROUGH -INS AS SHOWN ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. HOWEVER,
IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT MAY VARY FROM
WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE
OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL
PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
7. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.C. AND STATE AND
LOCAL CODES AS THEY APPLY.
8. ALL MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE J -BOX.
9. ANY FEES ASSOCIATED WITH CONSTRUCTION AND INSPECTION SHALL BE BORNE BY THE CONTRACTOR IN
ORDER TO DELIVER TO THE OWNER A FINISHED BUILDING, READY FOR OCCUPANCY AND 100%
OPERATION.
10. ALL PANEL BOARDS SHALL BE LABELED WITH RESPECT TO THEIR TITLE, VOLTAGE, AND PHASE; I.E.
PANEL "A" 208Y /120 /30. LABEL SHALL BE PHENOLIC PLASTIC WITH WHITE LETTERS AND BLACK
BACKGROUND. LABELS SHALL BE PERMANENTLY FIXED TO THE EQUIPMENT.
11. PANEL BOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE
INSIDE DOOR.
12. ANY COSTS INCURRED DUE TO LACK OF COMMUNICATION AMONG THE TRADES SHALL BE BORNE BY
THE CONTRACTOR.
13. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS
FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE
PROPOSAL FOR MATERIALS AND LABOR, BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE
RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.
14. TRADE NAMES ARE GIVEN TO CLARIFY TYPE OF PRODUCT AND QUALITY DESIRED.
15. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUIT'S INSTALLATION,
TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS
ADEQUATE IN SIZE AND MAKE -UP FOR THE MECHANICAL AND /OR KITCHEN EQUIPMENT TO BE
INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE, OR LOAD IS ENCOUNTERED WHICH WOULD ALTER
THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE
TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON
THE CONTRACTOR.
16. ALL ITEMS IN THE NOTES, SCHEDULES AND LEGEND MAY NOT NECESSARILY APPEAR ON THESE
DRAWINGS.
17. MINIMUM WIRE SIZE SHALL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL BE 3/4 ". ALL WIRING
SHALL BE RUN IN CONDUIT AND ALL CIRCUITS SHALL CONTAIN GREEN GROUND WIRE.
18. ALL 15 & 20 AMP, 125 VOLT ELECTRICAL OUTLETS SHALL COMPLY w/2005 NEC 210.8 (B)(2) WHICH
WILL REQUIRE RESTROOMS, ROOFS, MECH. ROOMS, KITCHENS AND BARS TO BE GFCI PROTECTED.
PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON
cvey OfETUI "1"1`
19.
JUN 0 5 2N8
PERMIT CENTER
21. ALL CONDUIT SHALL BE RUN CONCEALED, INSIDE WALLS OR IN OR UNDER FLOOR SLAB. ALL CONDUIT
SHALL BE RUN PERPENDICULAR OR PARALLEL & FOLLOW SURFACE CONTOURS AS MUCH AS PRACTICAL.
THE DRAWINGS OR SCHEDULES.
Al 1 EMPTY 1 P'1r . /rr SHALL 1 BE INSTALLED rr% WITI 1 PULL 1 STRINGr
20. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
22. ALL WORK SHALL COMPLY W/ THE RULES & REGULATIONS OF THE MALL. essoff 3
eu
c DRAWN BY:
TRG
REVISIONS:
n
A
POWER PLANS,
LEGEND, NOTES
AND SCHEDULES
SHEET NO.
it
E1.O
LI
WIRE z LOAD WATTS z WIRE CB
CB & LOAD SERVED c o o c, LOAD SERVED COND.
0 COND. w 0- s A OB s C w
1 20/1 12, 3/4 REACH -IN FREEZER J20 1 240 r 2 860-07 SODA DISPENSER 12, 3/4 20/1 2
3 20/1 12, 3/4 MICROWAVE OVEN 815 3 / 840' 4 B60-05 CARBONATOR 12, 3/4 20/1 4
5 20/1 12, 3/4 HEATED HOLDING SHELF B40-36 5 1560 720 6 866 -01 MOCHALATTA DISPENSER 12, 3/4 20/1 6
7 20/1 12, 3/4 BLENDER B68 7 500 1560 8 SPARE 20/1 8
9 20/1 12, 3/4 BLENDER B68 9 3016 10 314 UNDERCOUNTER REFRIG. 12, 3/4 20/1 10
11 40 8, 3/4 COFFEE BREWER C21 -01 11 3016 840 1632 12 J60 -01 ICE MAKER 12, 3/4 20/1 12
13 � 13 �0 14 LTG CONTACTOR / TIME CLOCK 12, 3/4 20/1 14
15 20/1 12, 3/4 CASH REGISTERS (10) I70 -01 15 240 16 CONVENIENCE RECEPTACLE 12 3/4 20/1 16
17 20/1 12, 3/4 CONVENIENCE RECEPTACLES 17 6000 180 3872 18 610 CONVECTION OVEN 8, 1 40 18
19 70 4, 1 1 /4 WATER HEATER c1 19 3872 6000 20 20
21 21 3872 6000 22 3 22
23 3 23 1200 1000 24 SPARE 20/1 24
25 20/1 12, 3/4 CINNABON SIGN L11 -01 25 200 f' 1200 26 TELEPHONE RECEPTACLE 12, 3/4 20/1 26
27 20/1 12, 3/4 • CINNABON SIGN L11 -01 27 1000 1000 28 SPARE 20/1 28
29 20/1 SPARE 29 1000 30 SPARE 20/1 30
31 SPACE 31 0 32 SPACE 32
33 SPACE 33 0 00 34 34
35 SPACE 35 36 36
37 37 0 0 0 38 38
39 39 0 + 0 40 40
41 41 0 42 42
NOTES:
Qt VERIFY W/ P.C.
IG ISOLATED CIRCUIT & ISOLATED GROUND WIRE
TOTAL: I 17908 17292 19020
PANEL LOAD ANALYSIS "A"
SYMBOL LEGEND
cb SINGLE RECEPTACLE
db DUPLEX RECEPTACLE
QUADPLEX RECEPTACLE
® SPECIAL VOLTAGE OR AMPERAGE
• TELEPHONE OUTLET
JQ JUNCTION BOX
ELECTRICAL PANEL
7 DAY 24 HOUR TIME CLOCK AND ELECTRICALLY HELD LIGHTING CONTACTOR
FOR CONTROL OF SIGNAGE.
NEW PANEL BOARD. PROVIDE WORKING CLEARANCES PER N.E.C.
CONDENSING UNIT MOUNTED ON TOP OF WALK -IN BOX, PROVIDE DISCONNECT
AS REQUIRED TO TERMINATE POWER.
10 CIRCUITS USED TO POWER THE ELECTRONIC REGISTERS AND COMPUTERS
SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE
NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL
AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO
THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO
THE GROUND TERMINAL ISOLATED FROM NEUTRAL DO NOT USE CONDUIT FOR
GROUNDING AS THIS IS NOT ADEQUATE AT HIGH FREQUENCIES. CASH
REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES
SHALL BE HUBBELL #IG -5362.
11 120V, 10, 20A CIRCUIT, 660 WATTS FOR REACH -IN REFRIGERATOR.
12 120V, 10, 20A CIRCUIT, FOR FREEZER DOOR HEATER & LTS.
13 208V, 30, 4 WIRE, 100A DISCONNECT FOR WATER HEATER. VERIFY
REQUIREMENTS W/ MANUFACTURER & INSPECTOR.
O. ELECTRICAL CONTRACTOR SHALL PROVIDE 1" CONDUIT WITH PULLWIRE FROM
CASH /WRAP TO TELEPHONE BACKBOARD.
O. 208V, 10, 20A CIRCUIT, 3.8 KW FOR FREEZER REFRIGERATION.
16 LIGHTING IS FURNISHED BY LANDLORD AS COMMON TO THIS AREA.
TOTAL CONNECTED LOAD: 54,220 WATTS
LIGHTS
KITCHEN
MISC. /SPARES
FANS
WTR HTR
TOTAL
2.4
30.1
3.7
10 0 100%
REMAIN ER x 5@%
3.0
19.6
3.7
18.00
54.2
18.00
44.3
123.0A
ELECTRICAL POWER PLAN
SCALE: 1/2' = 1' -0 "'
REVISIONS
No changes shall be made to thP scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FIE COPY
Permit No. kweddi
Dl�.r review approval is subject to errors omissions.
I,ppra�ra" of construction d� �. authorize
the violation of any adopted Receipt
approved Field Copy and �s Is ��:
By
Date:
City of Tukwila
BULL DING DIVISION
REMOTE STORAGE POWER PLAN
SCALE 1/2" = 1' -r
12 POSITION, SURFACE MOUNTED
NEW PANEL
VOLTAGE 120/208V 3 04W
40 AMP MAIN BREAKER
COORDINATE AIC REQUIREMENTS W/ POWER COMPANY
& LANDLORD
o o
CB &RE LOAD SERVED c LOAD WATTS 1-L11 c LOAD SERVED WIRE CB
ca COND. w a � A OB OC w COND. ca
1 30 10, 3/4 FREEZER CONDENSING UNIT A40.03 1 0 1882 2 SPACE - 2
1882
3 2 3 0 192 4 SPACE - 4
5 20/1 12, 3/4 FREEZER LIGHTS/ DOOR A40.05 5 0 6 SPACE - 6
7 20/1 12, 3/4 REACH -IN REFRIG. J10 7 660 8 SPACE - 8
9 20/1 12, 3/4 CONY. OUTLETS 9 i 060 1000 10 SPACE - 10
11 20/1 SPARE 11 0 12 SPACE - 12
NOTES:
QVERIFY W/ P.C.
IG ISOLATED CIRCUIT & ISOLATED GROUND WIRE
TOTAL CONNECTED LOAD: 5,976 WATTS
ITEM
LIGHTS
KITCHEN
MISC. /SPARES
FANS
TOTAL
LOAD (Kw)
DIVERSITY
125%
100%
10 0 106X
100%
DEMAND (Kw)
16.7A
J1 0
F EQUIPMENT SCHEDULE - ELECTRICAL
2 ELECTRICAL
DESCRIPTION MANUFACTURER MODEL - - REMARKS
o FURNISH INSTALL AMP KW HP VOLT PH CONN HGT.
B10 -208 CONVECTION OVEN (SINGLE DECK) LANG ECCO- LMDR480 /60101 -68KIT EQ. SUPP. GC 32.24 208 3 PLUG 18" NOTE #3
B15 MICROWAVE OVEN AMANA LD1OMP EQ. SUPP. GC 13 120 1 PLUG 24"
B40 -36 HEATED HOLDING SHELF HATCO GRS-36 EQ. SUPP. GC 4.6 120 1 PLUG 18"
COCA COLA OWNER OWNER 7 1/3 , 120 1 PLUG 72"
860 -07 SODA pTPENSER LANCER COLA
866 -01 MOCHA
LATTA DISPENSER CRATHCO D25-4CB (3 GAL BOWL) EQ OWNER SUPP. OWNER GC B 1 /5 115....1 PLUG. 24 "... #
15 1 PLUG 24 NOTE 1.........
B68 BLENDER BLENDTEC ICB -3 SMOOTHER 13 EQ. SUPP. GC 13 120. 1 PLUG 24"
C21 -01 COFFEE BREWER . .. ... BUNN-O-MATIC . CWTF35-APS EQ. SUPP. GC 29 208 1 PLUG 42" NOTE #4
J14 REACH-IN REFRIGERATOR R RE RAT VICTORY RA- 1D--S7 EQ. SUPP. GC 5.5 1/3 120 1 PLUG , 18" NOTE #1
OR VICTORY UR -4 -SST EQ. SUPP. GC 7 1/5 115 1 PLUG 18" NOTE #1
J20........ REACH -IN FREEZER VICTORY FA -ID -S7 EQ. SUPP. GC 8.5 1/3 115 1 PLUG 18" NOTE #1...._.._.. ........
J70 --01 CASH REGISTER SEE OWNER SEE OWNER OWNER GC 2.0 115 , 1 PLUG 24" NOTE #2
J60 -01 ICE MAKER MANITOWAC SY-0424A EQ. SUPP. GC 13.6 115 1 30"
L11 -01 CINNABON SIGN CINNABQN SIGN VENDOR CINNABON SIGN VENDOR CINN. S.V. GC VERIFY 120 1 DIRECT AS REQ'D
A40.03 FREEZER MASTER BILT CL- 156 -200 EQ SUPP. GC 1.6/1 8.1 2.0
115/208 1 DIRECT NOTE #5
NOTE #1: PROVIDE HACK TYPE CIRCUIT BREAKER.
NOTE #2: E.C. TO INSTALL (1) I.G. DUPLEX, (1) GENERAL DUPLEX, AND (1) TELEPHONE OUTLET FOR EACH REGISTER LOCATION.
NOTE #3: WALL RECEPTACLE PROVIDED W/ EQUIPMENT.
NOTE #4: 3 WIRES PLUS GROUND REQUIRED.
NOTE #5: HARD WIRED W/ SEPERATE JUNCTION BOXES FOR 115V & 208 -230V, VERIFY W/ MFG.
GENERAL ELECTRICAL NOTES
1. THE G.C. IS RESPONSIBLE FOR ALL TEMPORARY POWER AS NECESSARY.
2. COORDINATE ALL ELECTRICAL INSTALLATION RESPONSIBILITIES w /OWNER IN FIELD PRIOR TO BID.
3. THE G.C. IS RESPONSIBLE FOR ALL FLOOR AND WALL PENETRATIONS FOR ELECTRICAL AND MECHANICAL
WORK. ALL SUCH OPENINGS SHALL BE FRAMED AND REINFORCED. NO PENETRATIONS SHALL BE CUT
WITHOUT PRIOR AUTHORIZATION BY THE LANDLORD.
4. G.C. TO VERIFY AND RECEIVE APPROVAL FROM MALL MANAGEMENT PRIOR TO TRENCHING.
5. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL EQUIPMENT NEUTRAL AND GROUND WIRING AS
REQUIRED.
6. THE EQUIPMENT ROUGH -INS AS SHOWN ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. HOWEVER,
IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT MAY VARY FROM
WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE
OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL
PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
7. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.C. AND STATE AND
LOCAL CODES AS THEY APPLY.
8. ALL MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE J -BOX.
9. ANY FEES ASSOCIATED WITH CONSTRUCTION AND INSPECTION SHALL BE BORNE BY THE CONTRACTOR IN
ORDER TO DELIVER TO THE OWNER A FINISHED BUILDING, READY FOR OCCUPANCY AND 100%
OPERATION.
10. ALL PANEL BOARDS SHALL BE LABELED WITH RESPECT TO THEIR TITLE, VOLTAGE, AND PHASE; I.E.
PANEL "A" 208Y /120 /30. LABEL SHALL BE PHENOLIC PLASTIC WITH WHITE LETTERS AND BLACK
BACKGROUND. LABELS SHALL BE PERMANENTLY FIXED TO THE EQUIPMENT.
11. PANEL BOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE
INSIDE DOOR.
12. ANY COSTS INCURRED DUE TO LACK OF COMMUNICATION AMONG THE TRADES SHALL BE BORNE BY
THE CONTRACTOR.
13. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS
FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE
PROPOSAL FOR MATERIALS AND LABOR, BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE
RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.
14. TRADE NAMES ARE GIVEN TO CLARIFY TYPE OF PRODUCT AND QUALITY DESIRED.
15. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUIT'S INSTALLATION,
TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS
ADEQUATE IN SIZE AND MAKE -UP FOR THE MECHANICAL AND /OR KITCHEN EQUIPMENT TO BE
INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE, OR LOAD IS ENCOUNTERED WHICH WOULD ALTER
THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE
TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON
THE CONTRACTOR.
16. ALL ITEMS IN THE NOTES, SCHEDULES AND LEGEND MAY NOT NECESSARILY APPEAR ON THESE
DRAWINGS.
17. MINIMUM WIRE SIZE SHALL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL BE 3/4 ". ALL WIRING
SHALL BE RUN IN CONDUIT AND ALL CIRCUITS SHALL CONTAIN GREEN GROUND WIRE.
18. ALL 15 & 20 AMP, 125 VOLT ELECTRICAL OUTLETS SHALL COMPLY w/2005 NEC 210.8 (B)(2) WHICH
WILL REQUIRE RESTROOMS, ROOFS, MECH. ROOMS, KITCHENS AND BARS TO BE GFCI PROTECTED.
PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON
cvey OfETUI "1"1`
19.
JUN 0 5 2N8
PERMIT CENTER
21. ALL CONDUIT SHALL BE RUN CONCEALED, INSIDE WALLS OR IN OR UNDER FLOOR SLAB. ALL CONDUIT
SHALL BE RUN PERPENDICULAR OR PARALLEL & FOLLOW SURFACE CONTOURS AS MUCH AS PRACTICAL.
THE DRAWINGS OR SCHEDULES.
Al 1 EMPTY 1 P'1r . /rr SHALL 1 BE INSTALLED rr% WITI 1 PULL 1 STRINGr
20. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
22. ALL WORK SHALL COMPLY W/ THE RULES & REGULATIONS OF THE MALL. essoff 3
eu
c DRAWN BY:
TRG
REVISIONS:
n
A
POWER PLANS,
LEGEND, NOTES
AND SCHEDULES
SHEET NO.
it
E1.O
F EQUIPMENT SCHEDULE - ELECTRICAL
2 ELECTRICAL
DESCRIPTION MANUFACTURER MODEL - - REMARKS
o FURNISH INSTALL AMP KW HP VOLT PH CONN HGT.
B10 -208 CONVECTION OVEN (SINGLE DECK) LANG ECCO- LMDR480 /60101 -68KIT EQ. SUPP. GC 32.24 208 3 PLUG 18" NOTE #3
B15 MICROWAVE OVEN AMANA LD1OMP EQ. SUPP. GC 13 120 1 PLUG 24"
B40 -36 HEATED HOLDING SHELF HATCO GRS-36 EQ. SUPP. GC 4.6 120 1 PLUG 18"
COCA COLA OWNER OWNER 7 1/3 , 120 1 PLUG 72"
860 -07 SODA pTPENSER LANCER COLA
866 -01 MOCHA
LATTA DISPENSER CRATHCO D25-4CB (3 GAL BOWL) EQ OWNER SUPP. OWNER GC B 1 /5 115....1 PLUG. 24 "... #
15 1 PLUG 24 NOTE 1.........
B68 BLENDER BLENDTEC ICB -3 SMOOTHER 13 EQ. SUPP. GC 13 120. 1 PLUG 24"
C21 -01 COFFEE BREWER . .. ... BUNN-O-MATIC . CWTF35-APS EQ. SUPP. GC 29 208 1 PLUG 42" NOTE #4
J14 REACH-IN REFRIGERATOR R RE RAT VICTORY RA- 1D--S7 EQ. SUPP. GC 5.5 1/3 120 1 PLUG , 18" NOTE #1
OR VICTORY UR -4 -SST EQ. SUPP. GC 7 1/5 115 1 PLUG 18" NOTE #1
J20........ REACH -IN FREEZER VICTORY FA -ID -S7 EQ. SUPP. GC 8.5 1/3 115 1 PLUG 18" NOTE #1...._.._.. ........
J70 --01 CASH REGISTER SEE OWNER SEE OWNER OWNER GC 2.0 115 , 1 PLUG 24" NOTE #2
J60 -01 ICE MAKER MANITOWAC SY-0424A EQ. SUPP. GC 13.6 115 1 30"
L11 -01 CINNABON SIGN CINNABQN SIGN VENDOR CINNABON SIGN VENDOR CINN. S.V. GC VERIFY 120 1 DIRECT AS REQ'D
A40.03 FREEZER MASTER BILT CL- 156 -200 EQ SUPP. GC 1.6/1 8.1 2.0
115/208 1 DIRECT NOTE #5
NOTE #1: PROVIDE HACK TYPE CIRCUIT BREAKER.
NOTE #2: E.C. TO INSTALL (1) I.G. DUPLEX, (1) GENERAL DUPLEX, AND (1) TELEPHONE OUTLET FOR EACH REGISTER LOCATION.
NOTE #3: WALL RECEPTACLE PROVIDED W/ EQUIPMENT.
NOTE #4: 3 WIRES PLUS GROUND REQUIRED.
NOTE #5: HARD WIRED W/ SEPERATE JUNCTION BOXES FOR 115V & 208 -230V, VERIFY W/ MFG.
GENERAL ELECTRICAL NOTES
1. THE G.C. IS RESPONSIBLE FOR ALL TEMPORARY POWER AS NECESSARY.
2. COORDINATE ALL ELECTRICAL INSTALLATION RESPONSIBILITIES w /OWNER IN FIELD PRIOR TO BID.
3. THE G.C. IS RESPONSIBLE FOR ALL FLOOR AND WALL PENETRATIONS FOR ELECTRICAL AND MECHANICAL
WORK. ALL SUCH OPENINGS SHALL BE FRAMED AND REINFORCED. NO PENETRATIONS SHALL BE CUT
WITHOUT PRIOR AUTHORIZATION BY THE LANDLORD.
4. G.C. TO VERIFY AND RECEIVE APPROVAL FROM MALL MANAGEMENT PRIOR TO TRENCHING.
5. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL EQUIPMENT NEUTRAL AND GROUND WIRING AS
REQUIRED.
6. THE EQUIPMENT ROUGH -INS AS SHOWN ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. HOWEVER,
IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT MAY VARY FROM
WHAT IS SHOWN. THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE
OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL
PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR.
7. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.C. AND STATE AND
LOCAL CODES AS THEY APPLY.
8. ALL MOUNTING HEIGHTS ARE TO THE CENTERLINE OF THE J -BOX.
9. ANY FEES ASSOCIATED WITH CONSTRUCTION AND INSPECTION SHALL BE BORNE BY THE CONTRACTOR IN
ORDER TO DELIVER TO THE OWNER A FINISHED BUILDING, READY FOR OCCUPANCY AND 100%
OPERATION.
10. ALL PANEL BOARDS SHALL BE LABELED WITH RESPECT TO THEIR TITLE, VOLTAGE, AND PHASE; I.E.
PANEL "A" 208Y /120 /30. LABEL SHALL BE PHENOLIC PLASTIC WITH WHITE LETTERS AND BLACK
BACKGROUND. LABELS SHALL BE PERMANENTLY FIXED TO THE EQUIPMENT.
11. PANEL BOARDS SHALL CONTAIN A TYPEWRITTEN DIRECTORY WITH A PLASTIC COVER AFFIXED TO THE
INSIDE DOOR.
12. ANY COSTS INCURRED DUE TO LACK OF COMMUNICATION AMONG THE TRADES SHALL BE BORNE BY
THE CONTRACTOR.
13. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS
FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE
PROPOSAL FOR MATERIALS AND LABOR, BECAUSE OF DIFFICULTIES ENCOUNTERED, WILL NOT BE
RECOGNIZED IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE.
14. TRADE NAMES ARE GIVEN TO CLARIFY TYPE OF PRODUCT AND QUALITY DESIRED.
15. IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY, PRIOR TO ANY INDIVIDUAL CIRCUIT'S INSTALLATION,
TO VERIFY WITH ALL OTHER TRADES CONCERNED THAT THE CIRCUIT WITH DEVICES AS DRAWN IS
ADEQUATE IN SIZE AND MAKE -UP FOR THE MECHANICAL AND /OR KITCHEN EQUIPMENT TO BE
INSTALLED. IF ANY CONFLICT IN VOLTAGE, PHASE, OR LOAD IS ENCOUNTERED WHICH WOULD ALTER
THE CIRCUIT SIZE, THIS CONTRACTOR SHALL NOTIFY THE ENGINEER OR OWNER IMMEDIATELY. FAILURE
TO DO SO SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT CIRCUIT CHANGE DIRECTLY UPON
THE CONTRACTOR.
16. ALL ITEMS IN THE NOTES, SCHEDULES AND LEGEND MAY NOT NECESSARILY APPEAR ON THESE
DRAWINGS.
17. MINIMUM WIRE SIZE SHALL BE #12 AWG AND MINIMUM CONDUIT SIZE SHALL BE 3/4 ". ALL WIRING
SHALL BE RUN IN CONDUIT AND ALL CIRCUITS SHALL CONTAIN GREEN GROUND WIRE.
18. ALL 15 & 20 AMP, 125 VOLT ELECTRICAL OUTLETS SHALL COMPLY w/2005 NEC 210.8 (B)(2) WHICH
WILL REQUIRE RESTROOMS, ROOFS, MECH. ROOMS, KITCHENS AND BARS TO BE GFCI PROTECTED.
PROVIDE EITHER INDIVIDUAL GFI DEVICES OR GFI CIRCUIT BREAKERS, UNLESS SPECIFICALLY NOTED ON
cvey OfETUI "1"1`
19.
JUN 0 5 2N8
PERMIT CENTER
21. ALL CONDUIT SHALL BE RUN CONCEALED, INSIDE WALLS OR IN OR UNDER FLOOR SLAB. ALL CONDUIT
SHALL BE RUN PERPENDICULAR OR PARALLEL & FOLLOW SURFACE CONTOURS AS MUCH AS PRACTICAL.
THE DRAWINGS OR SCHEDULES.
Al 1 EMPTY 1 P'1r . /rr SHALL 1 BE INSTALLED rr% WITI 1 PULL 1 STRINGr
20. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
22. ALL WORK SHALL COMPLY W/ THE RULES & REGULATIONS OF THE MALL. essoff 3
eu
c DRAWN BY:
TRG
REVISIONS:
n
A
POWER PLANS,
LEGEND, NOTES
AND SCHEDULES
SHEET NO.
it
E1.O