Loading...
HomeMy WebLinkAboutPermit EL08-0694 - FIDELITY INVESTOR CENTERFIDELITY INVESTOR CENTER 304 STRANDER BL ELO8-694 City1111f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 304 STRANDER BL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -694 Issue Date: 08/07/2008 Permit Expires On: 02/03/2009 Tenant: Name: FIDELITY INVESTOR CENTER Address: 304 STRANDER BL , TUKWUILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Phone: 206 - 802 -6071 Address: 633 SOUTHCENTER MALL TRAILER #3 , TUKWILA WA Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Phone: Expiration Date: 12/16/2009 DESCRIPTION OF WORK: NEW ELECTRICAL CONDUIT, WIRING, PANELS, TRANSFORMER AND ALL MATERIALS AND SUPPLIES FOR SHELL CONSTRUCTION OF STAND ALONE BUILDING. Value of Electrical: $76,603.00 Fees Collected: $1,532.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: 7`-0 b I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: e 7 �� t�'7 5/Le-lA>e./ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -694 Printed: 08 -07 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 304 STRANDER BL TUKW FIDELITY INVESTOR CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -694 ISSUED 06/06/2008 08/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: iday-eri Date: /-7 0cK doc: Cond -Elec EL08 -694 Printed: 08-07 -2008 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: b84(-12.:0-04/.6 Site Address:._0/1 ,��rlvr,,�a -�� 11 %k zi (G/ � Suite Number: Floor: Tenant Name: P lrP /i rh ✓ P6/ P� >� r� New Tenant: Yes Property Owners Name: Gt) LA 7' 4, e /e/ Carr d>-q ;,., Mailing Address: H44)/ 41 i P 8/ / 7''t ❑..No City /t, II State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: -5-- 717-777,77-e.-! Mailing Address: / la E -Mail Address: we ELECTRICAL CONTRACTOR INFORMATION Day Teleph City - , ,; la State L4, As Zip ,Fax Company Name: 7TH � e Se err, , r> Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 70, 6 63 -C v Scope of Work (please provide detailed information): NP.uJ e f LC); Y';s-7 e /s, - s re-r- // 014_}4-,-i' / Grp lr'es Orr She 1) / A s -, G / h << /' /d ' Will service be altered? ❑ Yes ❑' No Adding more than 50 amps? 0 Yes la-No Type of Use: Type of work: [c�New El Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: El/Puget Sound Energy ❑ Seattle City Light H:1Applicahons Forms- Applicanona On Late 4 -2107 - Flectrical Pcrmit Applicanon.dne bh Page 1 of 2 RESIDENTIAL. NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) S55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no added/altered circuits) ❑ Service change with added/altered circuits S75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) 57.00 ea ❑ Meter /mast repair S65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service 580.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fec schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: "WC / 4- P D / ca X20 Mailing Address: 633 /e-/ .3 -- �Day Telephone: kLL); t/4_ City Date: C - 2-- 4,67( State Zip Date Application Accepted: (` D Date Application Expires: (.. Staff Initials: W HAApplications'•Fonns -Applications (M Line 4 -2477 - Electrical Permit Applicatton.dne bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -694 Address: 304 STRANDER BL TURIN Status: APPROVED Suite No: Applied Date: 06/06/2008 Applicant: FIDELITY INVESTOR CENTER Issue Date: Receipt No.: R08 -02870 Initials: WER User ID: 1655 Payment Amount: $1,226.00 Payment Date: 08/07/2008 11:06 AM Balance: $0.00 Payee: SEA -TAC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8847 1,226.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,226.00 Total: $1,226.00 �r,.-.2 :;?/07 71C TC:Ti'i:_ 122.0C doc: Receipt -06 Printed: 08-07 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -694 Address: 304 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 06/06/2008 Applicant: FIDELITY INVESTOR CENTER Issue Date: Receipt No.: R08 -01976 Initials: WER User ID: 1655 Payment Amount: $306.50 Payment Date: 06/06/2008 10:53 AM Balance: $1,226.00 Payee: GENSLER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10136159 306.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 306.50 Total: $306.50 3348 06/05 9711 TOTAL 423900 doc: Receipt -06 Printed: 06 -06 -2008 INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 AC Project: 1 -1T`I Type of Inspection: 100 Address: 3o _ ! 5Tk /p • _ 7 pal /��(�\ Date Called: .--- Special Instructions: Date Wanted: 0 2102- a:m Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ero taid 0�� Inspector: 664AJK Date: 01/02 107 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit (a- 671 NO. � CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 • Project: t , -rt>t Vt Type of Inspection: 70°3/Z)00/ Address: Sat/ S-„ Jr� Date Called: 111 Special Instructi ns: Date Wanted: / Z /lr- a.m P. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS." IWQ V I fat Va &Ic ti,00C JP 2.100 - 7 a5Pt CoV645 k r) Pi4A) Lfs GS o,J x.00 TbP e0J1 P'1 E wp (/4 At -10 scoPE oc _ etaxnat art 4aJkt..-- or 5 y 4 10.1{. - Koutt4 ti.1 1 5620c,E -1003— 1005 Inspector: irti Date: 510k El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit )9L twig-0 PERMIT NO.I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 0 7005 Soy s �iottDate Called: d- Address: Special Instructions: Date Wanted: . m. /0/31 Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: YA O. Vk . ' t . .,564)1 C Coarx Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: YA O. Vk . ' t . .,564)1 C Coarx t>$( 3 3 , LAST chtt ikni P Inspector: � 664‘) JJ Date: /O�31/0y El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: I INSPECTION RECORD // q t Retain a copy with permit 60T- a + INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION "- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ( ��� I, Type of Inspection: � pl � Address: �D� 5 Date Called: r—. Special Instruc ons: Date Wanted: O 41. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Si _ $60.00 REINSPECTION FEE REQ Date: or \_, to inspect on fee mus ri t Prior p t be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2008 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Project Info Project Address Fidelity Investments Date 6/2/2008 304 strander Blvd. For Building Department Use p�.� FP r ,..i+T+,.,_�PY gA p� i 6 u Oe v` Takwila, WA Applicant Name: Rag Engineers Applicant Address: 70 Fargo Street, Suite 800 Boston, EA ff t Applicant '� ant Phone: 617- 345 -9885 f "t Project Description L'% New Building ❑ Addition ❑ Alteration ❑ Plans Induded requirements. - Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lightmg Wattage Location (floor /room no.) • Occupancy Description Allowed Watts per ft2 ** Area in ft Allowed x Area let floor Retail Banking 1.50 7200.0 10800.0 1 65.0 65.0 -LA i `4 20a1 " From Table 15-1 (over) - document all exceptions on form Provosed Lighting Wattage REVIEWED FOR otal AlloweC watts 10800.0 Location — (floor /room no.) — — Fixture De toUL)L. LUMFLIAN criptioNFPA 70 — NEC Fixtu of s Watts/ Fixture Watts Proposed Elea. Closet Surface mtd. Wraparound 1 65.0 65.0 -LA i `4 20a1 IV City & Tukwila DIVISION ,._BUILDING Total Proposed Watts may not exceed Total Allowed Watts for Interior otal Proposed Watts 65.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. LO8- qLp !EDE @VED JUN 0 6 2008 ?ERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior 'Lighting Summary (back) 2008 Washington State Nonresidential Energy Code Compliance Fumes LTG -INT Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers OOther Qualification Checklist Note: If occupancy type Is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' - LPA (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /barss 1.3 Post office 1.1 Dormitory 1.0 Retail1e, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ", assembly space? 1.0 Theater, motion picture 1.2 Health care clinic. 1.0 Theater, performing arts 1.6 , Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'•° 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies° (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG-EXT1 2005 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info ProjAddres:Fieelity investments Date 6/2/2008 304 Strander Blvd. For Building Department Use 1711 Fi L E C PY rrIt No. Takvila, WA Name: RDE Engineers Appl. Name 70 Fargo Street, Suite 800 Boston, MA Appl.Phone617- 345 -9885 Pr Project Description J New ❑ Addition ❑ Alteration ❑ Plans Included requirements. r -- Refer to WSEC Section 1513 for controls and commissioning Compliance Option ® Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Li tin Wattage Tradable Locations Description Allowed Watts per ft2 or per if Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Canopies and Overhangs Front Entrance 1.25 W/ft2 350.0 437.5 Canopies and Overhangs • Rear Entrance 1.25 W/ft2 18.0 22.5 1i X1w V TuKWd7 Tradable Proposed Lighting Wattage Total Allowed Watts 460.0 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Front 6^ Dovnlight 4 65.0 260.0 Rear 6^ Dovnlight 1 65.0 65.0 1i X1w V TuKWd7 Total Proposed Watts may not exceed Tot Non - Tradable Maximum Allowed Li ���OEar FOR MPLIANCE CODE C h aO -NEC Total Proposed Watts 325.0 Non - Tradable Locations Des iption U iI 1 Allowed Was r ft2 or pe If Area (ft2), perimeter (10 or # of items Allowed Watts x ft2 (or x If) L- 1i X1w V TuKWd7 Non - Tradable Proposed Lighting Watt Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Proposed Watts may not exceed Allowed Watts for Category LO8 (�qv ,1,79=M442a 4.11.113,11,71. RECEIVED JUN 0 6 2008 ?ERMIT CENTEh • 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Fidelity Investments Date 6/2/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E02.01 n.a. 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations a. a. vertical glazing Indicate vertical glazing on plans a. a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location E02.01 n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n. a. 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans z02. 01 a. a. 1513.7 Commissioning • Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yea 1514 Max. watts Indicate watts for each exit sign E01.01 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture [- n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n . a. 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -694 DATE: 06 -06 -08 PROJECT NAME: FIDELITY INVESTOR CENTER SITE ADDRESS: 304 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Buil g Div'iion n Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06 -10 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 07 -08 -08 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by L&tI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. SEA TAC ELECTRIC INC Business and Licensing Information Name SEA TAC ELECTRIC INC UBI No. 601510212 Phone 2538725553 Status ACTIVE Address 7056 S 220TH ST License No. SEATAEI077RW Suite /Apt. License Type ELECTRICAL CONTRACTOR City KENT Effective Date 12/16/1993 State WA Expiration Date 12/16/2009 Zip 98032 Suspend Date County KING Separation Date Business Type CORPORATION Previous License SEATAEC131 QC Parent Company Next License Associated License HARGRT *974CD Specialty 1 GENERAL Specialty 2 UNUSED MASTER ELECTRICIAN INFORMATION License HARGRT *974CD Name HARGREAVES, TOM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 Bond Amount HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, KATHERINE SECRETARY 12/17/1993 JORDAN, TOM VICE PRESIDENT 01/01/2002 BURKS, ROY VICE PRESIDENT 12/17/1993 12/15/1995 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date http s : / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= SEATAEI077RW 08/07/2008 M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 E01.01 ELEC LEGEND, NOTES & ABBREVIATIONS.dwg [30x42] May 30, 2008 — 10:05am slunn POWER DISTRIBUTION tss m 208Y/120 VOLT PANELBOARD, SURFACE MOUNTED REFER TO SCHEDULE OF PANELBOARDS 480Y/277 VOLT PANELBOARD, SURFACE MOUNTED REFER TO SCHEDULE OF PANELBOARDS DRY TYPE TRANSFORMER K —RATED "KT3" — INDICATES KVA RATING OF TRANSFORMER REFER TO DRY TYPE K —RATED TRANSFORMER SCHEDULE CURRENT TRANSFORMER CABINET MQv UTILITY METER AND SOCKET GROUND BAR �G3 FIRE ALARM LEGEND FACP FM FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL KEY BOX �7110cd FIRE ALARM AUDIBLE AND VISUAL DEVICE, NUMERAL INDICATES F WP CANDELA VALUE, 'WG' DENOTES WEATHERPROOF FIRE ALARM MANUAL PULL STATION O FIRE ALARM SMOKE DETECTOR, PHOTO ELECTRIC UNLESS NOTED OTHERWISE RAI RTS TS REMOTE ALARM INDICATOR DUCT MOUNTED SMOKE DETECTOR REMOTE TEST STATION SPRINKLER TAMPER FLOW SWITCH FS SPRINKLER WATER FLOW SWITCH ZONE MONITORING MODULE FIRE ALARM RED ROTATING BEACON, EXTERIOR MOUNTED, WEATHER PROOF SPRINKLER BELL MOTOR & CONTROLS LEGEND 60AS 50AF FUSED DISCONNECT SWITCH, 3 —POLE, IN NEMA TYPE 1 ENCLOSURE, UNLESS OTHERWISE NOTED. "3R" — INDICATES NEMA TYPE 3R ENCLOSURE "60AS" — INDICATES 60AMP SWITCH "50Ar — INDICATES 50AMP FUSES "WP" — WEATHERPROOF BRANCH CIRCUIT & FEEDER LEGEND —• 7 R22A -1,3,5 BRANCH CIRCUIT OR FEEDER CONCEALED IN FINISHED AREAS BRANCH CIRCUIT OR FEEDER, CONCEALED IN OR UNDER FLOOR SLAB BRANCH CIRCUIT OR FEEDER TURNING UP TOWARDS OBSERVER BRANCH CIRCUIT OR FEEDER TURNING DOWN AWAY FROM OBSERVER CONDUIT STUBBED ABOVE CEILING BRANCH CIRCUIT HOME RUN TICKS INDICATE QUANTITY OF CONDUCTORS, GROUND CONDUCTORS ARE NOT INDICATED. NO TICKS INDICATES 2 #12 & 1 #12G IN 3/4"C MINIMUM. R22A -1,3,5 INDICATES PANEL AND CIRCUIT DESIGNATION FROM WHICH HOMERUN SHALL ORIGINATE. EACH CIRCUIT SHALL BE 20A-1P (20AMP SINGLE POLE) UNLESS NOTED OTHERWISE. FLEXIBLE CONNECTION TO EQUIPMENT. RACEWAY AND CONDUCTOR RATING TO MATCH ASSOCIATED BRANCH CIRCUIT OR FEEDER SITE LEGEND --UE— UT— UNDERGROUND ELECTRIC UNDERGROUND TELEPHONE REVISIONS No changes shall be made fothe of scope of work without prior approval Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. LIGHTING FIXTURE LEGEND FR AR1 0 2,a AR1• EW1 LIGHTING FIXTURE LIGHTING FIXTURE SHADING INDICATES FIXTURE EMERGENCY (LIFE SAFETY) WITH BATTERY BALLAST EXIT SIGN LIGHTING FIXTURE, WALL MOUNTED, ARROWS AND EXIT FACE AS (SHADED) AS INDICATED. ABBREVIATIONS A /AMP AMPERE AC ADA AF AFF AFG AIC AL AT ATS AWG B C CA CAN CB CKT CPU CU dB DC DWG EC EMT FDR FLMT FREQ GEC GFI GND HH HP HVAC HZ IG JB KVA KW KWH ALTERNATING CURRENT AMERICANS WITH DISABILITIES ACT AMPERE FRAME ABOVE FINISHED FLOOR ABOVE FINISH GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMPERE TRIP AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BURIED CONDUIT CABLE CABLE TELEVISION CIRCUIT BREAKER CIRCUIT CENTRAL PROCESSING UNIT COPPER CENTERLINE DECIBEL DIRECT CURRENT DRAWING ELECTRICAL CONTRACTOR ELECTRIC METALLIC TUBING FEEDER FLEXIBLE LIQUID TIGHT METALLIC TUBING FREQUENCY GROUNDING ELECTRODE CONDUCTOR GROUND FAULT INTERRUPTING GROUND HANDHOLE HORSEPOWER HEATING, VENTILATING AND AIR CONDITIONING HERTZ ISOLATED GROUND JUNCTION BOX KILOVOLT— AMPERE KILOWATT KILOWATT —HOURS LTG MCB MEC M/G MH MLO MTD MTG NC NEC NO NTS OPD POS PVC PWR RGS RMS RPM SN STP SWBD TB TEL TERM TVSS TYP UG U.O.N. UPS UTP VA W WP LIGHTING MAIN CIRCUIT BREAKER MASSACHUSSETTS ELECTRIC CODE MOTOR /GENERATOR SET MANHOLE MAIN LUGS ONLY MOUNTED MOUNTING NORMALLY CLOSED CONTACT NATIONAL ELECTRIC CODE NORMALLY OPEN CONTACT NOT TO SCALE NUMBER OVER CURRENT PROTECTION DEVICE PROVIDED UNDER OTHER SECTIONS POLYVINYL CHLORIDE POWER RIGID GALVANIZED STEEL ROOT MEAN SQUARE VALUE REVOLUTIONS PER MINUTE SOLID NEUTRAL SHIELDED TWISTED —PAIR SWITCHBOARD TERMINAL BLOCK TELEPHONE TERMINAL TRANSIENT VOLTAGE SURGE SUPPRESSER TYPICAL UNDERGROUND UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY UNSHIELDED TWISTED —PAIR VOLTS VOLT— AMPERE WATTS WEATHERPROOF WIRING DEVICE LEGEND 5 GFI m DUPLEX RECEPTACLE, GROUNDING TYPE, RATED 20A, 125V "5 "— INDICATES CIRCUIT NUMBER "GFI"— INDICATES INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER "WP" — INDICATES WEATHERPROOF JUNCTION BOX SWITCH LEGEND Sa S T SINGLE POLE SWITCH, RATED 20A, 120/277V, "a" LOWER CASE LETTER INDICATES FIXTURE SWITCH CONTROL TIMER SWITCH, WATTSTOPER #TS -400 OR APPROVED EQUAL TIME CLOCK, REFER TO DETAIL EL003 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION. LEGEND NOTES: 1. REFER TO SPECIFICATIONS, ARCHITECTURAL DRAWINGS, APPLICABLE SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION ASSOCIATED WITH EACH DEVICE ILLUSTRATED ON THIS LEGEND. 2. SUBSCRIPTS ILLUSTRATED ON THE LEGEND WITH ONE SYMBOL ONLY TO MINIMIZE SPACE. ANY SUBSCRIPT INDICATED WITHIN A LEGEND FAMILY MAY BE APPLIED TO A CORRESPONDING SYMBOL. 3. ABBREVIATIONS SUCH AS "WP" MAY BE APPLIED TO ANY SYMBOL. REVIEWED FON F CODE C� QP NEB NFPA JUN 13208 F0LE COPY Permit NolSJ Pi; review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. cipt is of approved Field Copy and By Date: a 7-a3 City of Tukwila BUILDING DIVISION ELO8 �9y OFidellity- INVESTIINENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGIN'EER'S IA Issue 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 -345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name 20080076_01.01 IDescription ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS IScale NTS E01.01 02006 Gensler RECEIVFP 1N 0 6 AIM PERMIT LENTEH LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURERS CATALOG NUMBER DESCRIPTION LAMPS INPUT REMARKS NO. TYPE VOLTS WATTS R 8" DIAMETER DOWNLIGHT WITH WHITE REGRESSED DOOR AND FRESNEL LENS, SUITABLE FOR WET LOCATION 2 32W TT 277 64 GOTHAM #AF- 2- 32TRT -8AR- 277 —GEB10 R1 8" DIAMETER DOWNLIGHT WITH WHITE REGRESSED DOOR AND FRESNEL LENS, SUITABLE FOR WET LOCATION 2 32W TT 277 64 PROVIDE WITH EMERGENCY BALLAST, SEE NOTE 8 GOTHAM #AF -2- 32TRT -8AR- 277— GEB10 —ELR F 4' SURFACE MOUNTED WRAPAROUND WITH ACRYLIC REFRACTOR /LENS AND EMERGENCY BALLAST 2 32W T8 3500K 277 65 PROVIDE WITH EMERGENCY BALLAST, SEE NOTE 8 METALUX #WS232A- 277— EB8 —EL4 EW1 DUAL LITE LEWSG — ARROWS —NA GREEN LED SINGLE FACE, SELF — CONTAINED EXIT SIGN — MIRROR BACKGROUND W/ BATTERY ARROWS AND MOUNTING AS INDICATED — LED 277 3.6 SEE NOTE 7 NOTES: 1. NOTES 2 -9 APPLY TO ALL APPLICABLE LIGHTING FIXTURES. THE REMARKS COLUMN SHALL NOTE ADDITIONAL REQUIREMENTS. 2. FIXTURES SPECIFIED WITH CATALOG NUMBERS ESTABLISH QUALITY LEVEL FOR EQUAL FIXTURES FROM MANUFACTURERS LISTED WITHOUT CATALOG NUMBERS. WHERE ONLY ONE MANUFACTURER LISTED, THERE SHALL BE NO SUBSTITUTION. 3. VERIFY EXACT MOUNTING CONDITIONS AND PROVIDE APPROPRIATE ACCESSORIES AND HARDWARE TO ACCOMMODATE REQUIREMENTS. 4. PROVIDE ALL FLUORESCENT FIXTURES WITH ELECTRONIC BALLASTS WITH MAXIMUM THD OF 20 %, PF GREATER THAN 97% AND BF GREATER THAN 0.88. BALLASTS SHALL BE PROGRAMMED RAPID START WITH END —OF— LAMP —LIFE PROTECTION. ACCEPTABLE MANUFACTURERS SHALL BE ADVANCE, GENERAL ELECTRIC, OSRAM SYLVANIA OR UNIVERSAL. 5. BALLAST EFFICIENCY SHALL BE GREATER THAN THAT REQUIRED TO ENSURE THAT THE VALUE LISTED FOR INPUT WATTS IS NOT EXCEEDED. 6. FLUORESCENT LAMPS SHALL HAVE A MINIMUM CRI OF 82. LAMP COLOR SHALL BE AS LISTED IN THE SCHEDULE. 7. PROVIDE EXIT SIGNS WITH ARROWS AND MOUNTING ACCESSORIES AS INDICATED ON THE PLANS. 8. BATTERY BACKED FLUORESCENT BALLASTS SHALL PROVIDE A MINIMUM OF 3000 LUMENS OF ILLUMINATION FROM LAMP AS INDICATED FOR 90 MINUTES. BALLAST SHALL BE EQUAL TO TYPE B30 BY BODINE. M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 E01.01 ELEC LEGEND, NOTES & ABBREVIATIONS.dwg [30x42] May 30, 2008 — 10:05am slunn POWER DISTRIBUTION tss m 208Y/120 VOLT PANELBOARD, SURFACE MOUNTED REFER TO SCHEDULE OF PANELBOARDS 480Y/277 VOLT PANELBOARD, SURFACE MOUNTED REFER TO SCHEDULE OF PANELBOARDS DRY TYPE TRANSFORMER K —RATED "KT3" — INDICATES KVA RATING OF TRANSFORMER REFER TO DRY TYPE K —RATED TRANSFORMER SCHEDULE CURRENT TRANSFORMER CABINET MQv UTILITY METER AND SOCKET GROUND BAR �G3 FIRE ALARM LEGEND FACP FM FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL KEY BOX �7110cd FIRE ALARM AUDIBLE AND VISUAL DEVICE, NUMERAL INDICATES F WP CANDELA VALUE, 'WG' DENOTES WEATHERPROOF FIRE ALARM MANUAL PULL STATION O FIRE ALARM SMOKE DETECTOR, PHOTO ELECTRIC UNLESS NOTED OTHERWISE RAI RTS TS REMOTE ALARM INDICATOR DUCT MOUNTED SMOKE DETECTOR REMOTE TEST STATION SPRINKLER TAMPER FLOW SWITCH FS SPRINKLER WATER FLOW SWITCH ZONE MONITORING MODULE FIRE ALARM RED ROTATING BEACON, EXTERIOR MOUNTED, WEATHER PROOF SPRINKLER BELL MOTOR & CONTROLS LEGEND 60AS 50AF FUSED DISCONNECT SWITCH, 3 —POLE, IN NEMA TYPE 1 ENCLOSURE, UNLESS OTHERWISE NOTED. "3R" — INDICATES NEMA TYPE 3R ENCLOSURE "60AS" — INDICATES 60AMP SWITCH "50Ar — INDICATES 50AMP FUSES "WP" — WEATHERPROOF BRANCH CIRCUIT & FEEDER LEGEND —• 7 R22A -1,3,5 BRANCH CIRCUIT OR FEEDER CONCEALED IN FINISHED AREAS BRANCH CIRCUIT OR FEEDER, CONCEALED IN OR UNDER FLOOR SLAB BRANCH CIRCUIT OR FEEDER TURNING UP TOWARDS OBSERVER BRANCH CIRCUIT OR FEEDER TURNING DOWN AWAY FROM OBSERVER CONDUIT STUBBED ABOVE CEILING BRANCH CIRCUIT HOME RUN TICKS INDICATE QUANTITY OF CONDUCTORS, GROUND CONDUCTORS ARE NOT INDICATED. NO TICKS INDICATES 2 #12 & 1 #12G IN 3/4"C MINIMUM. R22A -1,3,5 INDICATES PANEL AND CIRCUIT DESIGNATION FROM WHICH HOMERUN SHALL ORIGINATE. EACH CIRCUIT SHALL BE 20A-1P (20AMP SINGLE POLE) UNLESS NOTED OTHERWISE. FLEXIBLE CONNECTION TO EQUIPMENT. RACEWAY AND CONDUCTOR RATING TO MATCH ASSOCIATED BRANCH CIRCUIT OR FEEDER SITE LEGEND --UE— UT— UNDERGROUND ELECTRIC UNDERGROUND TELEPHONE REVISIONS No changes shall be made fothe of scope of work without prior approval Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. LIGHTING FIXTURE LEGEND FR AR1 0 2,a AR1• EW1 LIGHTING FIXTURE LIGHTING FIXTURE SHADING INDICATES FIXTURE EMERGENCY (LIFE SAFETY) WITH BATTERY BALLAST EXIT SIGN LIGHTING FIXTURE, WALL MOUNTED, ARROWS AND EXIT FACE AS (SHADED) AS INDICATED. ABBREVIATIONS A /AMP AMPERE AC ADA AF AFF AFG AIC AL AT ATS AWG B C CA CAN CB CKT CPU CU dB DC DWG EC EMT FDR FLMT FREQ GEC GFI GND HH HP HVAC HZ IG JB KVA KW KWH ALTERNATING CURRENT AMERICANS WITH DISABILITIES ACT AMPERE FRAME ABOVE FINISHED FLOOR ABOVE FINISH GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMPERE TRIP AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BURIED CONDUIT CABLE CABLE TELEVISION CIRCUIT BREAKER CIRCUIT CENTRAL PROCESSING UNIT COPPER CENTERLINE DECIBEL DIRECT CURRENT DRAWING ELECTRICAL CONTRACTOR ELECTRIC METALLIC TUBING FEEDER FLEXIBLE LIQUID TIGHT METALLIC TUBING FREQUENCY GROUNDING ELECTRODE CONDUCTOR GROUND FAULT INTERRUPTING GROUND HANDHOLE HORSEPOWER HEATING, VENTILATING AND AIR CONDITIONING HERTZ ISOLATED GROUND JUNCTION BOX KILOVOLT— AMPERE KILOWATT KILOWATT —HOURS LTG MCB MEC M/G MH MLO MTD MTG NC NEC NO NTS OPD POS PVC PWR RGS RMS RPM SN STP SWBD TB TEL TERM TVSS TYP UG U.O.N. UPS UTP VA W WP LIGHTING MAIN CIRCUIT BREAKER MASSACHUSSETTS ELECTRIC CODE MOTOR /GENERATOR SET MANHOLE MAIN LUGS ONLY MOUNTED MOUNTING NORMALLY CLOSED CONTACT NATIONAL ELECTRIC CODE NORMALLY OPEN CONTACT NOT TO SCALE NUMBER OVER CURRENT PROTECTION DEVICE PROVIDED UNDER OTHER SECTIONS POLYVINYL CHLORIDE POWER RIGID GALVANIZED STEEL ROOT MEAN SQUARE VALUE REVOLUTIONS PER MINUTE SOLID NEUTRAL SHIELDED TWISTED —PAIR SWITCHBOARD TERMINAL BLOCK TELEPHONE TERMINAL TRANSIENT VOLTAGE SURGE SUPPRESSER TYPICAL UNDERGROUND UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY UNSHIELDED TWISTED —PAIR VOLTS VOLT— AMPERE WATTS WEATHERPROOF WIRING DEVICE LEGEND 5 GFI m DUPLEX RECEPTACLE, GROUNDING TYPE, RATED 20A, 125V "5 "— INDICATES CIRCUIT NUMBER "GFI"— INDICATES INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER "WP" — INDICATES WEATHERPROOF JUNCTION BOX SWITCH LEGEND Sa S T SINGLE POLE SWITCH, RATED 20A, 120/277V, "a" LOWER CASE LETTER INDICATES FIXTURE SWITCH CONTROL TIMER SWITCH, WATTSTOPER #TS -400 OR APPROVED EQUAL TIME CLOCK, REFER TO DETAIL EL003 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION. LEGEND NOTES: 1. REFER TO SPECIFICATIONS, ARCHITECTURAL DRAWINGS, APPLICABLE SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION ASSOCIATED WITH EACH DEVICE ILLUSTRATED ON THIS LEGEND. 2. SUBSCRIPTS ILLUSTRATED ON THE LEGEND WITH ONE SYMBOL ONLY TO MINIMIZE SPACE. ANY SUBSCRIPT INDICATED WITHIN A LEGEND FAMILY MAY BE APPLIED TO A CORRESPONDING SYMBOL. 3. ABBREVIATIONS SUCH AS "WP" MAY BE APPLIED TO ANY SYMBOL. REVIEWED FON F CODE C� QP NEB NFPA JUN 13208 F0LE COPY Permit NolSJ Pi; review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. cipt is of approved Field Copy and By Date: a 7-a3 City of Tukwila BUILDING DIVISION ELO8 �9y OFidellity- INVESTIINENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGIN'EER'S IA Issue 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 -345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name 20080076_01.01 IDescription ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS IScale NTS E01.01 02006 Gensler RECEIVFP 1N 0 6 AIM PERMIT LENTEH r i r-r ...— I__. -1.. 1 11 1 li„ ` 1 11 \ 11 NEW TIMECLOCK 'Tcye REFER TO DETAIk ON 1 E08.01 FOR ADDITIONAL 1 1 INFORMATION '(TYPICt_) 1 1 / it 11 J— T ! 1 \ -NEWI I'MbPP\ 1' -..`\ NEW TIMECLOCK 'TC2' H 11 111_./ 1I \ 1II \ r I l � != =. — =1.r1211 — — I 1 :E==='1 1P-I R1 11 \ / 11 �3 11 F [1 Mt 1 3 REFElr TO PART1 PLAN ADDITIONAL INFORMATION O.Q1 FON ON DRAWING E • 1 / TiI • if .1 Ir 111 \ L..41 1 -1 F Im Ti III ___11 it - - -, II `n 1 11 I_ 111 111 II 111 1 I— ato fi - - - -�: __ 11 wP r WP.. R 1A-6 VIAL• 'TC2' 11 11 -rt t 11 11 11 11 EW1T MDP -1 MDP -3 VIA 'TC1' I rJ 8 TC2' R11 3 1 IR R 1 KEY NOTES KELECTICAL CONTRACTOR SHALL UTILIZE #1 OAWG. THROUGHOUT TO ACCOMODATE FOR VOLTAGE DROP. REVIEWED CODE CO MP N :Pik 70 - NEC JUN 13 NOB City Of Tukwila ON BUILDING DIVI ELO9 j9LJ SHEET NOTES LIGHTING NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS, INCLUDING BUT NOT LIMITED TO, REFLECTED CEILING PLANS AND ELEVATIONS FOR ASSOCIATED NOTES, MOUNTING DETAILS AND EXACT LOCATIONS OF ALL LIGHTING FIXTURES. 3. PROVIDE COMMON FACE PLATE AND REQUIRED METAL INTERIOR BOX BARRIERS FOR ALL MULTIPLE GANG SWITCH LOCATIONS. 4. CIRCUIT NUMBERS ARE DIAGRAMMATIC. EXACT NUMBERS SHALL BE DETERMINED IN THE FIELD AND REFLECTED ON AS —BUILT DOCUMENTATION BY THE ELECTRICAL CONTRACTOR. THE ASSOCIATED CIRCUIT NUMBER AND SWITCH LEG NOMENCLATURE THAT ARE APPLIED TO EACH LIGHTING FIXTURE AND CONTROLLING DEVICE INFER INTERCONNECTING BRANCH CIRCUITRY. 5. VOLTAGE DROP HAS BEEN CONSIDERED IN THE DESIGN OF ALL BRANCH CIRCUIT AND FEEDER SIZES BASED UPON THE ILLUSTRATED EQUIPMENT LAYOUTS AND SHORTEST CONDUCTOR /RACEWAY ROUTING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEVIATIONS TAKEN THAT WILL INCREASE CONDUCTOR /RACEWAY ROUTING LENGTHS. BRANCH CIRCUITS LONGER THAN 75' FOR 120V AND 175' FOR 277V FROM PANEL TO LAST OUTLET SHALL BE INCREASED A MINIMUM OF ONE SIZE ABOVE THAT SPECIFIED TO LIMIT VOLTAGE DROP TO LESS THAN 3 %. 6. SURFACE MOUNTED FIXTURES (INCLUDING EXIT SIGNS) THAT CREATE OBSTRUCTIONS EXCEEDING 4 1/2 INCHES FROM THE CEILING SURFACE TO THE BOTTOM OF THE FIXTURE SHALL BE SPACED A MINIMUM OF 2'6" FROM ANY SPRINKLER HEAD. COORDINATE THE EXACT PLACEMENT OF ALL FIXTURES WITH THE REFLECTED CEILING PLAN AND THE FIRE PROTECTION CONTRACTOR. 7. PROVIDE CONSTANTLY ENERGIZED (UNSWITCHED) BRANCH CIRCUIT TO ALL EXIT SIGNS AND EGRESS LIGHTS FROM THE DESIGNATED BRANCH CIRCUIT AS INDICATED ON PLAN. 8. LIGHTING BRANCH CIRCUITRY SHALL BE INSTALLED IN CONDUIT FROM THE PANELBOARD TO THE FIRST OUTLET AND /OR WHERE EXPOSED. LIGHTING BRANCH CIRCUITRY MAY BE TYPE MC CABLE WHERE CONCEALED ABOVE SUSPENDED CEILINGS OR IN METAL STUD WALLS. M: \2008 \20080076 — Fidelity Seattle Base Building \ Electrical \20080076 E02.01 ELEC LTG PLAN 1ST FLOOR.dwg [30x42] May 30, 2008 — 10:05am slunn Fidelity 1 ISIVESTMEIVTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com 0 Issue Date & Issue Description By Check -- 01 06/02/08 SJ SL ISSUE FOR CONSTRUCTION Seal /Signature 1 Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name 20080076J02.01 Description ELECTRICAL LIGHTING PLAN FIRST FLOOR Scale 1 /8 "= 1' —O" 0 2s' 16' E02.01 02006 Gensler RECEIVE JUN 06 2000 PERMIT CENTER (2)4" C. TO TELEPHONE POLE IN STREET. COORDINATE WITH SITE /CIVIL DRAWINGS PRIOR TO BID PAD MOUNTED UTILITY TRANSFORMER PROVIDED BY PSE L BOLLARDS, REFER TO DETAIL ON E08.01 FOR ADDITIONAL INFORMATION NEVI 'MDP' 1 "— -f1. CI T ft 7 R21A -5 G _ i 5 m 5 AF J REFER TO POWER RISER ON 1E09.01 FOR ADDITIONAL INFORMATION 11 11 11 11 11 11 11 11 11 u fE — EE - EE: -a o-. MDP- 20,22,24 (15A -3P) 3 #12 & 1 #12G. — 3/4 "C_ 1� 1 1 1 IL_ _j _ 1I 1 1444 ] iii it r- 1 L it- I1 REFER TO PART PLAN I1ITHIS SHEET FOR ADDITIq IAL INFORMATION 111 111 111 11 4777 777 LL. 444 LIGHTING CONTROL CABINET 'LC1A' (FUTURE) NEW PANEL 'H41A'— -NEW FLOOR MOUNTED 45kVA TRANSFORMER I I KT4 0 FACP NEW PANELS 'R21A' ELECTRIC CLOSET PART PLAN SCALE: 1 /4 " =1' -0" KEY NOTES OTHE ELECTRICAL CONTRACTOR SHALL PROVIDE ONE (1) 3/4" CONDUIT FOR CONNECTION TO POWER, ONE (1) 1" CONDUIT FOR CONNECTION FOR TELE /DATA AND ONE (1) 2" CONDUIT FOR A/V UNDER SLAB, STUB UP WITH BUSHING ON END OF CONDUIT AND PULLSTRING IN CONDUIT. COORDINATE STUB UP LOCATION WITH ARCHITECT PRIOR TO WORK. 2 THE ELECTRICAL CONTRACTOR PROVIDE ONE (1) 3/4" CONDUIT FOR CONNECTION TO POWER, (1) 3/4" CONDUIT FOR SECURITY, AND ONE (1) 2" CONDUIT FOR CONNECTION TO TELECOMM UNDER SLAB, STUB UP WITH BUSHING ON END OF CONDUIT AND PULLSTRING IN CONDUIT. COORDINATE STUB UP LOCATION WITH ARCHITECT PRIOR TO WORK. 3 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ONE (1) 3/4" 3 CONDUIT FOR CONNECTION TO POWER AND ONE (1) 1" CONDUIT FOR CONNECTION FOR TELE /DATA UNDER SLAB, STUB UP WITH BUSHING ON END OF CONDUIT AND PULLSTRING IN CONDUIT. COORDINATE STUB UP LOCATION WITH ARCHITECT PRIOR TO WORK. OLEAK DETECTION AND CONDENSATE PUMP LOCATED IN DRIP PAN UNDER CRAC -1 COOLING UNIT. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO WORK. REVIEWED FOR CODE COMP LIANCE NFPA 70 - NEC JUN 13 2008 City Of Tukwila BUILDING_DIUI:. ION E L68 (1,9j ALL UNDERGROUND STUB —UP LOCATIONS AND DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO BID. SHEET NOTES POWER NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR ASSOCIATED NOTES, MOUNTING DETAILS, HEIGHTS AND EXACT LOCATIONS OF ALL DEVICES. 3. CIRCUIT NUMBERS ARE DIAGRAMMATIC. EXACT NUMBERS SHALL BE DETERMINED IN THE FIELD AND REFLECTED ON AS —BUILT DOCUMENTATION BY THE ELECTRICAL CONTRACTOR. THE ASSOCIATED CIRCUIT NUMBERS THAT ARE APPLIED TO EACH DEVICE AND PIECE OF EQUIPMENT INFERS INTERCONNECTING BRANCH CIRCUITRY. INTERCONNECTING BRANCH WIRING SHALL BE SIZED EQUAL TO THE HOMERUN UNLESS NOTED OTHERWISE. 4. VOLTAGE DROP HAS BEEN CONSIDERED IN THE DESIGN OF ALL BRANCH CIRCUITRY AND FEEDER SIZES BASED UPON THE ILLUSTRATED EQUIPMENT LAYOUTS AND SHORTEST CONDUCTOR /RACEWAY ROUTING. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEVIATIONS TAKEN THAT WILL INCREASE CONDUCTOR /RACEWAY ROUTING LENGTHS. BRANCH CIRCUITS LONGER THAN 75' FOR 120V FROM PANEL TO LAST OUTLET SHALL BE INCREASED A MINIMUM OF ONE SIZE ABOVE THAT SPECIFIED TO LIMIT VOLTAGE DROP TO LESS THAN 3 %. FEEDERS SHALL FOLLOW SIMILAR GUIDELINES AND BE LIMITED TO 2% DROP. 5. POWER BRANCH CIRCUITRY SHALL BE INSTALLED IN CONDUIT FROM THE PANEL TO THE FIRST DEVICE AND /OR WHERE EXPOSED. POWER BRANCH CIRCUITRY MAY BE TYPE MC CABLE WHERE CONCEALED ABOVE SUSPENDED CEILINGS AND IN METAL STUD WALLS. M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 EO3.O1 ELEC PWR PLAN 1ST FLOOR.dwg [30x42] May 30, 2008 — 1O:O6am slunn Fidelity 1 RIVE STMEIVTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 1 L1Issue -- 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature Project Name 1)a 5 r� o Fidelity Investor Center — SEATTLE BRANCH Project Number 20080076 CAD File Name 20080076.103.01 Description ELECTRICAL POWER PLAN FIRST FLOOR Scale or= 1' -0" 0 2' 4' 8' 16' E03.01 02006 Gensler JIM 0 b Luue3 MIT CENTEh - - -- LINE I E 01: BUILDING OPENING IN MECHANICAL SCPE.::11EN EF -1 1/8HP • EF -3 1 /8HP /7 gEcu- 7.4FLA 7 =30AS Mj 1' MIN SLOPE OF ROOF BELOW R21 A -4 EF- 1/8HP MDP - 14;6,18 (15A -3P) NN, 3 #12 & 1 #12G., —3/4"C. SLOPE OF ROOF BELOW R21A -3 -I- MDP �- 2 4,6 (60A 3P) 3 #6.L:& 1 #1OG —3/4" C. i r 1/4":1' MIN SLOPE OF ROOF BELOW 1%49P-8,I100 2 '/ (60A 3P7 16— 1 #10G, al /4" C. SLOPE OF ROOF BELOW { KEY NOTES \-- RE1IrEW'ED�NCE CODE COMPLIANCE 70 - NEC JUN 13 2008 C� i Of Tukwila BUILDING DIVISION , ELDB- SHEET NOTES POWER NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR ASSOCIATED NOTES, MOUNTING DETAILS, HEIGHTS AND EXACT LOCATIONS OF ALL DEVICES. 3. CIRCUIT NUMBERS ARE DIAGRAMMATIC. EXACT NUMBERS SHALL BE DETERMINED IN THE FIELD AND REFLECTED ON AS —BUILT DOCUMENTATION BY THE ELECTRICAL CONTRACTOR. THE ASSOCIATED CIRCUIT NUMBERS THAT ARE APPLIED TO EACH DEVICE AND PIECE OF EQUIPMENT INFERS INTERCONNECTING BRANCH CIRCUITRY. INTERCONNECTING BRANCH WIRING SHALL BE SIZED EQUAL TO THE HOMERUN UNLESS NOTED OTHERWISE. 4. VOLTAGE DROP HAS BEEN CONSIDERED IN THE DESIGN OF ALL BRANCH CIRCUITRY AND FEEDER SIZES BASED UPON THE ILLUSTRATED EQUIPMENT LAYOUTS AND SHORTEST CONDUCTOR /RACEWAY ROUTING. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEVIATIONS TAKEN THAT WILL INCREASE CONDUCTOR /RACEWAY ROUTING LENGTHS. BRANCH CIRCUITS LONGER THAN 75' FOR 120V FROM PANEL TO LAST OUTLET SHALL BE INCREASED A MINIMUM OF ONE SIZE ABOVE THAT SPECIFIED TO LIMIT VOLTAGE DROP TO LESS THAN 3 %. FEEDERS SHALL FOLLOW SIMILAR GUIDELINES AND BE LIMITED TO 2% DROP. 5. POWER BRANCH CIRCUITRY SHALL BE INSTALLED IN CONDUIT FROM THE PANEL TO THE FIRST DEVICE AND /OR WHERE EXPOSED. POWER BRANCH CIRCUITRY MAY BE TYPE MC CABLE WHERE CONCEALED ABOVE SUSPENDED CEILINGS AND IN METAL STUD WALLS. M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 E03.02 ELEC PWR PLAN ROOF.dwg [30x42] May 30, 2008 — 10:06am slunn 0 Fidelity INVESTMENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 0 Issue -- 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 CAD File Name 20080076103.02 Description ELECTRICAL POWER PLAN ROOF I Scale 1/8"= 1' -0" 11—r"7 i 0 2' 4' 8' 16' E03.02 02006 Gensler RECEIVED JUN 06 2008 PERMIT CENTER COORDINATE EXACT LOCATION AND QUANTITIES WITH FIRE PROTECTION CONTRACTOR PRIOR TO BID COORDINATE LOCATION WOTH FIRE PROTECTION CONTRACTOR PRIOR TO BID /\ r (1I 110cd I �n +— — —r... FOR RTU -1 J \ H U FOR RTU -2 1r IL / II 1 III 11 11 II� / J j 7 11; COORDINATE EXACT LOCATION WITH FIRE MARSHALL PRIOR TO INSTALLATION 11 it 11 11 11 1 .1L.1 J fl 110cd KEY NOTES REVIEWED FOR CODE COMPLIANCE NFPA 70 W NEC 1 (6 2uf'3 City Of Tukwila ILD.NG DIVI ION SHEET NOTES FIRE ALARM NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES. 2. REFER TO ARCHITECTURAL DRAWINGS FOR ASSOCIATED NOTES, MOUNTING DETAILS, HEIGHTS AND EXACT LOCATIONS OF ALL DEVICES. 3. FIRE ALARM BRANCH CIRCUITRY SHALL BE INSTALLED IN CONDUIT FROM THE PANEL TO THE FIRST DEVICE AND /OR WHERE EXPOSED. FIRE ALARM BRANCH CIRCUITRY MAY BE TYPE MC CABLE WHERE CONCEALED ABOVE SUSPENDED CEILINGS AND IN METAL STUD WALLS. 4. MC CABLE FOR FIRE ALARM SERVICE SHALL HAVE A RED IDENTIFIER ALONG ITS ENTIRE LENGTH. JUNCTION BOX COVERS AND CONDUIT COUPLINGS FOR ALL FIRE ALARM WIRING RACEWAYS SHALL BE PAINTED RED PRIOR TO INSTALLATION. 5. MAINTAIN CONTINUITY OF BRANCH CIRCUITRY ASSOCIATED WITH ALL EXISTING FIRE ALARM DEVICES TO REMAIN. M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 E04.01 ELEC FA PLAN 1ST FLOOR.dwg [30x42] May 30, 2008 — 10:06am slunn Fidelily INVESTMENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 1 A Issue -- 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature 1 Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 CAD File Name 20080076J04.01 IDescription ELECTRICAL FIRE ALARM PLAN FIRST FLOOR I Scale 1/8"= 1' —O" ri"" " 'l 0 2 4 8' 16 E04.O1 02006 Gensler R CE VFP JUN 0 6 'N PERMIT CEN I b 3" 41/2" IDENTIFICATION OF PHASE AND SYSTEM 480Y/277V BROWN A ORANGE B YELLOW C GRAY N 208Y/120V BLACK RED BLUE WHITE NOTES: 1. REFER TO SPECIFICATIONS FOR ADDITIONAL NAMEPLATE AND /OR COLOR CODING REQUIREMENTS. 1/4" LETTERS (MINIMUM) 2. NAMEPLATE TO BE 1/16" THICK PLASTIC WITH WHITE CENTER LAMINATION. FACE SHALL BE BLACK, ENGRAVED LETTERS SHALL BE WHITE. 3. SECURE NAMEPLATE TO SURFACES WITH ADHESIVE CEMENT. 4. TYPICAL FOR MOUNTING TO ALL DISTRIBUTION EQUIPMENT (SWITCHGEAR, SWITCHBOARDS, PANELBOARDS, ETC.) D m PANELBOARD CONDUCTOR NAMEPLATE DETAIL EP010 z MECHANICAL EQUIPMENT 6' -6" r PROVIDE METAL CHANNEL WHERE REQUIRED. WEATHERPROOF LIGHTING FIXTURE WITH GUARD (HUBBELL #VWX- 152— VCG -15) CIRCUITRY IN RIGID METAL CONDUIT 120 VOLT DUPLEX, GROUND FAULT RECEPTACLE AND LIGHT SWITCH IN WEATHERPROOF BOX LB FITTING ROOF CURB ROOF ti PITCH POCKET FURNISHED - BY ELECTRICAL CONTRACTOR AND INSTALLED BY ROOFING CONTRACTOR REFER TO DRAWINGS FOR BRANCH CIRCUIT HOMERUN ROOF MEMBRANE AND INSULATION ROOF DECK D © TYPICAL ROOF TOP MECHANICAL EQUIPMENT LIGHTING & RECEPTACLE DETAIL EM012 CONCRETE CAP (PAINTED) PRIME & PAINT BOLLARD YELLOW (TYP.) 9" DIAMETER GALV. STEEL PIPE SCHEDULE 40 FILLED W /CONCRETE FINISH GRADE #2/0 BARE COPPER GROUND TO TRANSFORMER GROUNDING GRID *REFER TO UTILITY COMPANY FOR COMPLETE SPECIFICATION PRIOR TO BID. ' -9" DIAMETER CONCRETE FOOTING D ® PROTECTION BOLLARD DETAIL ES012 HOT NEUTRAL WALL SWITCH AC BALLAST EMERGENCY BALLAST SWITCHED HOT NEUTRAL AC BALLAST EMERGENCY BALLAST UNSWITCHED D EMERGENCY BALLAST WIRING DETAIL 8' -6" 6' -8" 4' -6" 4' -0" 1' -6" EXIT' FIRE MC m O O EMERGENCY LIGHTING EXIT SIGN CLOCK FIRE ALARM AUDIO /VISUAL DEVICES (MOUNTING HEIGHT MINIMUM TO BOTTOM OF STROBE, SEE NOTE 4) INTERCOM WALL TELEPHONES SWITCHES FIRE ALARM PULL STATION TELEPHONE /DATA OUTLETS RECEPTACLES FINISHED FLOOR NOTES: 1. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM FINISHED FLOOR TO CENTERLINE OF DEVICE EXCEPT EXIT SIGNS, CLOCKS, EMERGENCY LIGHTING AND FIRE ALARM A/V DEVICES. 2. DEVICES SHALL BE INSTALLED ON A COMMON VERTICAL CENTERLINE WHEREVER POSSIBLE. 3. ALL DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AS INDICATED ON THIS DETAIL UNLESS OTHERWISE NOTED. 4. STROBE HEIGHT ILLUSTRATED AT MAXIMUM HEIGHT. STROBE SHALL BE 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER. D ® TYPICAL DEVICE MOUNTING HEIGHTS DETAIL EM001 *PROVIDE MULTI —POLE CIRCUIT BREAKERS AS REQUIRED TO COMPLY WITH SECTION 210.4 OF THE NATIONAL ELECTRIC CODE SOURCE. REFER TO FLOOR PLANS FOR VOLTAGE OA OB N —• - 0A N • ELECTROMECHANICAL 7 DAY TIME CLOCK EQUAL TO TORK "W" SERIES WITH RESERVE POWER FEATURE IN NEMA 1 ENCLOSURE. PROVIDE WITH (4) SPST 40A CONTACTS UNLESS NOTED OTHERWISE. TIMING MOTOR VOLTAGE SHALL MATCH LIGHTING CIRCUIT VOLTAGE. • • TO LOAD. REFER TO FLOOR PLANS FOR ADDITIONAL DETAIL D TIME SWITCH DETAIL EL003 LABEL ALL RECEPTACLES WITH PANEL DESIGNATION AND CIRCUIT NUMBER. LABEL SHALL BE CLEAR MYLAR. P —TOUCH TYPE. RP10B2 -1 RP10B2 -3 COMPUTER RP10B2 -3 GENERAL D © TYPICAL RECEPTACLE LABEL REQUIREMENTS EP004 NOTES: ARC FLASH AND SHOCK HAZARD APPROPRIATE PPE REQUIRED 1. REFER TO SPECIFICATIONS FOR ADDITIONAL NAMEPLATE REQUIREMENTS. 2. PROVIDE ON ALL IN —LINE METER SOCKETS, SWITCHBOARDS, DISTRIBUTION PANELS, PANELBOARDS AND MOTOR CONTROL CENTERS IN ACCORDANCE WITH NEC 110.16. D © TYPICAL FLASH PROTECTION WARNING LABEL EP005 PIPE CLAMP ON STREET SIDE OF METER <5' -0" FROM POINT OF ENTRANCE SERVICE ENTRANCE EQUIPMENT CONDUCTOR SIZED PER NEC 250.66 G BONDING JUMPER NI • kJ STRUCTURAL STEEL NOTES: <10' -0" METAL UNDERGROUND WATER PIPE (DOMESTIC WATER AND FIRE PROTECTION WHERE BOTH AVAILABLE) 44 a. %"x10' -0" COPPER CLAD STEEL GROUND ROD #4/0 (TYP) 10 "0, 10" DEEP INSPECTION WELL EQUAL TO ERICO T416B (TYP.) FOOTING OUTSIDE WALL CONCRETE ENCASED ELECTRODE AT BOTTOM OF FIDDLING. SEE NOTE 3 #4/0 — '4'x10' -0" COPPER CLAD STEEL GROUND ROD (TYP. OF 3) 1. THIS DRAWING IS INTENDED TO ILLUSTRATE THE SERVICE GROUNDING REQUIREMENTS. REFER TO NEC ARTICLE 250 FOR ADDITIONAL DETAILS. 2. ALL CONNECTIONS SHALL BE EXOTHERMIC WELDS WITH THE EXCEPTION OF MECHANICAL LUGS IN THE SERVICE ENTRANCE EQUIPMENT. 3. PROVIDE 20' #4 AWG BARE COPPER IN LIEU OF BONDING TO REBAR WHERE 20' OF BARE REBAR IS NOT INSTALLED. D ELECTRIC SERVICE GROUNDING ELECTRODE DETAIL EG001 RE —SEED OR RESURFACE AS REQUIRED BY AREA EXCAVATED WARNING TAPE ENTIRE LENGTH OF TRENCH GRADE 24" (MIN) 3 " (MIN) + - ce 18" + + + + + + + + + F - + + + -I + + + + + + + + + + + + + + + + + W\ \,, \\4\ 0 + + r. + + + + i \\ . 12" (MIN) RACEWAY WITH ASSOCIATED CONDUCTORS. REFER TO DRAWINGS FOR SIZE AND TYPE COMPACTED CLEAN BACKFILL COMPACTED CLEAN BACKFILL NOTES: 1. THIS DETAIL IS INTENDED TO ILLUSTRATE REQUIREMENTS WHICH EXCEED THOSE REQUIRED BY NEC TABLE 300 -5. 2. WARNING TAPE SHALL BE DETECTABLE TYPE FOIL BACKED 4MIL POLYETHYLENE WITH FADE RESISTANT "BURIED ELECTRIC LINE BELOW' MINIMUM OF 18 INCHES ABOVE THE BURIED SERVICE. TAPE SHALL BE EQUAL TO T &B NAF -0708. 3. ALL ROADWAY CROSSING SHALL BE ENCASED WITH A MINIMUM OF 2 INCHES OF CONCRETE (TOP BOTTOM AND SIDES) EXTENDING A MINIMUM OF 2 FEET BEYOND EACH SIDE OF CROSSING. 4. ALL CONDUIT RISERS SHALL UTILIZE LONG RADIUS GALVANIZED RIGID STEEL SWEEPS. Eti D BURIED CONDUIT DETAIL ES013 LOS -IoR4 M: \2008 \20080076 — Fidelity Seattle Base Building \Electrical \20080076 E08.01 ELEC DETAILS.dwg [30x42] May 30, 2008 — 10:06am slunn CI Fidelily INVESTMENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS 0 Issue -- 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210 -1964 T 617 - 345 -9885 F 617 - 345 -4226 W www.rdkengineers.com Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL Seal /Signature 1 Project Name Fidelity Investor Center — SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name 2008007608.01 Description ELECTRICAL DETAILS Scale NTS E08.01 02006 Gensler RECEIVED JUN 0 6 1008 PERMIT CENTER PANEL MAI N CIR. 1 3 5 AMPS/ POLES 7 9 11 13 15 17 19 21 23 25 27 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 MDP - NEW 400A MCB *SERVICE ENTRANCE RATED PANELBOARD SCHEDULE VOLTS 480/277V AMPS 400A BUS PH /WIRE 3/4 MOUNT. AIC LOC. SURFACE 22 KAIC CLOSET GROUND BUS YES 100% FEED THRU LUGS NO 200% NEUTRAL NO DESCRIPTION OF LOAD L- EXTERIOR L- EXTERIOR (EM) SPARE SPARE SPARE SPARE LOAD kVA LOAD BY PHASE, kVA A B C LOAD kVA 0.20 0.12 0.00 12.40 12.32 12.20 12.20 12.20 12.20 DESCRIPTION OF LOAD RTU -1 AMPS/ POLES 60/3 CIR. 2 4 0.00 0.00 0.00 12.20 12.20 12.20 12.20 12.20 12.20 RTU -2 60/3 6 8 10 SPARE SPARE SPARE 0.00 0.00 0.00 2.05 2.05 2.05 SPARE SPARE SPARE 0.00 0.00 0.00 0.39 0.39 0.39 SPACE 0.00 0.00 SPACE 0.00 0.00 29 31 SPACE 0.00 0.00 33 35 37 SPACE 0.00 0.00 2.05 2.05 2.05 ACCU -1 15/3 12 14 16 18 0.39 0.39 0.39 CRAC -1 15/3 20 22 24 0.00 SPACE 26 0.00 SPACE 28 0.00 SPACE 30 SPACE SPACE 0.00 0.00 0.00 SPACE 32 0.00 SPACE 0.00 0.00 0.00 39 41 225/3 NEW PANEL 'H41A' TOTAL kVA BY PHASE - 0.00 0.00 0.00 2.75 1 .88 1.76 2.75 1.88 1.76 SPACE 45KVA TRANSFORMER 80/3 34 36 .38 40 29.79 28.84 28.60 TOTAL KVA- 87.23 TOTAL AMPERES- 104.97 42 PANEL MAIN CIR. 1 AMPS/ POLES H41A - NEW 225A MCB PANELBOARD SCHEDULE VOLTS AMPS PH /WIRE 480/277V 225A BUS 3/4 MOUNT. AIC LOC. SURFACE 22 KAIC ELEC. ROOM GROUND BUS YES 100% FEED THRU LUGS NO 200% NEUTRAL NO DESCRIPTION OF LOAD SPACE LOAD kVA LOAD BY PHASE, kVA A B C LOAD kVA 3 5 7 0.00 DESCRIPTION OF LOAD SPACE SPACE 0.00 0.00 SPACE 0.00 SPACE SPACE SPACE AMPS/ POLES CIR. 2 4 6 9 SPACE 0.00 SPACE 8 11 13 SPACE 0.00 SPACE 10 SPACE 0.00 SPACE 12 15 17 19 SPACE 0.00 SPACE 14 SPACE 0.00 SPACE 0.00 SPACE SPACE 16 18 21 SPACE 0.00 SPACE 20 23 SPACE 0.00 SPACE 22 25 27 29 31 SPACE 0.00 SPACE 24 SPACE 0.00 SPACE 0.00 33 35 37 39 41 SPACE 0.00 SPACE 0.00 SPACE SPACE SPACE SPACE 26 28 30 32 SPACE SPACE SPACE 0.00 0.00 SPACE SPACE SPACE 0.00 SPACE 0.00 TOTAL kVA BY PHASE - 0.00 0.00 0.00 SPACE SPACE 34 36 38 40 42 TOTAL KVA- 0.00 AMPERES- 0.00 PANEL MAIN CIR. 1 AMPS/ POLES 3 5 20/1 20/1 20/1 R21A (SECTION 1) - NEW PANELBOARD SCHEDULE 150A MCB VOLTS AMPS PH /WIRE 3/4 208Y/120V 225A BUS MOUNT. AIC LOC. SURFACE 10 KAIC ELEC. ROOM DESCRIPTION OF LOAD LOAD kVA LOAD BY PHASE, kVA A B C R- ELECTRIC CLOSET 0.36 0.55 R -ROOF 0.18 0.68 CONDENSATE PUMP (CRAC) 0.36 7 20/1 FACP 1.00 2.20 0.56 9 20/1 SPARE 0.00 11 20/1 SPARE 0.00 0.00 LOAD kVA 0.25 0.50 1.20 1.20 13 15 20/1 20/1 SPARE 0.00 0.00 SPARE 17 20/1 SPARE 0.00 19 20/1 SPARE 0.00 0.00 21 23 25 27 29 31 33 35 37 39 41 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE 0.00 SPARE SPARE SPARE 0.00 0.00 0.00 SPARE TOTAL kVA BY PHASE - 2.75 1.88 0.00 1 .76 PANELBOARD SCHEDULE PANEL R21A (SECTION 2) - NEW MAIN CIR. 43 AMPS/ POLES 20/1 VOLTS AMPS PH /WIRE 208Y/120V 225A BUS 3/4 MOUNT. AIC LOC. SURFACE 10 KAIC ELEC. ROOM GROUND BUS YES 100% FEED THRU LUGS NO 200% NEUTRAL YES DESCRIPTION OF LOAD LOAD kVA LOAD BY PHASE, kVA A B C LOAD kVA SPARE 0.00 45 20/1 SPARE 47 49 51 53 55 57 20/1 20/1 20/1 20/1 20/1 20/1 SPARE SPARE SPARE SPARE 0.00 DESCRIPTION OF LOAD SPARE AMPS/ POLES CIR. 20/1 44 SPARE 20/1 46 SPARE 0.00 0.00 SPARE 0.00 SPARE SPARE SPARE 20/1 20/1 20/1 48 50 52 54 SPARE 59 61 20/1 20/1 SPARE 0.00 0.00 SPARE SPARE 20/1 20/1 56 58 SPARE 63 65 67 69 71 73 75 77 79 81 20/1 20/1 20/1 20/1 20/1 SPARE 0.00 SPARE SPARE 20/1 20/1 60 62 SPARE 0.00 SPARE SPARE 0.00 SPARE 0.00 SPACE 0.00 SPACE SPACE 0.00 83 SPACE SPACE 0.00 SPARE SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE 20/1 20/1 20/1 20/1 0.00 SPACE SPACE 64 66 68 70 72 74 76 78 80 82 TOTAL kVA BY PHASE - (BOTH SECTIONS) TOTAL kVA BY PHASE - 0.00 SPACE 2.75 1.76 TOTAL KVA- (BOTH SECTIONS) TOTAL KVA- TOTAL AMPS- 0.00 6.39 84 M: \2008 \20080076 - Fidelity Seattle Base Building \Electrical \20080076 E09.01 ELEC SCHEDULES.dwg [30x42] May 30, 2008 - 10:06am slunn PAD MOUNTED UTILITY XFMR PROVIDED BY PSE SEE NOTE 7 - REFER TO BOLLARD DETAIL ON E08.01 FOR ADDITIONAL INFORMATION NEW UTILITY METER SOCKET AND CT SEE NOTE 5 MEL GRADE WP SEE NOTE 6 INCOMING UTILITY SERVICE BY PSE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL EXCAVATION REQUIREMENTS FOR TRANSFORMER PAD WITH PSE PRIOR TO BID. SEE DETAIL EG001 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION 4#500KCMIL IN 4" C. TYPE USE. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT RUN IN FIELD PRIOR TO WORK. FIDELITY ELECTRIC CLOSET SEE DETAIL EG001 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION 4 NEW FLOOR MOUNTED 45KVA TRANSFORMER POWER RISER NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES THAT MAY PERTAIN TO THIS DRAWING. 2. THIS DRAWING IS INTENDED TO ILLUSTRATE MAJOR EQUIPMENT AND REQUIRED INTERCONNECTIONS. REFER TO THE FLOOR PLANS FOR EXACT LOCATIONS AND THE SPECIFICATIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. 3. REFER TO THE DRY TYPE TRANSFORMER SCHEDULE(S) FOR CONDUCTOR AND RACEWAY REQUIREMENTS NOT SPECIFICALLY NOTED ON TRANSFORMER PRIMARY AND SECONDARY CONNECTIONS. 4. THE SERVICE AND ALL SEPARATELY DERIVED SYSTEMS SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 250 OF THE NEC. BOND ALL ELECTRICALLY CONDUCTIVE MATERIALS SUCH AS METAL PIPING SYSTEMS AND STRUCTURAL STEEL TO THE GROUNDING SYSTEM. REFER TO DETAILS FOR ADDITIONAL INFORMATION. 5. NEW UTILITY METER SOCKET WITH PROVISION FOR TEST SWITCH AND 400A CT CABINET. PROVIDE 1" LETTERS ON A PERMANENT LABEL INDICATING ADDRESS ON METER SOCKET. EC SHALL PROVIDE THE SOCKET AND CT ENCLOSURE. COORDINATE WITH PSE (PUGET SOUND ENERGY) PRIOR TO WORK FOR EXACT METER SOCKET AND CT CABINET REQUIREMENTS. ALL EQUIPMENT SHALL BE APPROVED BY PSE PRIOR TO PURCHASE. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE RIGID GALVANIZED CONDUIT SWEEP AND SCHEDULED 80 PVC EXPANSION COUPLING. ROOF 1ST FLOOR PARTIAL ELECTRICAL RISER DIAGRAM N.T.S. KNOX BOX AND BEACON LOCATED OUTSIDE. COORDINATE LOCATION WITH FIRE LOCAL FIRE DEPARTMENT. SEE NOTE 12] ocs FACP REFER TO NOTE #2,11 1#6 IN 3/4"C. ELECTRIC ROOM R21A-7 REFER TO NOTE #5 REFER TO NOTE #4 (2) DEDICATED PHONE LINE, REFER TO NOTE #10 TENANT SPACE NOTES: 1. THIS DRAWING IS INTENDED TO ILLUSTRATE MAJOR EQUIPMENT AND THE INTENDED INTERCONNECTIONS. REFER TO THE FLOOR PLAN FOR EXACT LOCATIONS AND QUANTITIES OF DEVICES. REFER TO THE MANUFACTURER'S WIRING DIAGRAMS FOR INTERCONNECTION REQUIREMENTS. INTERCONNECTION DETAILS SHALL BE INCLUDED IN THE SHOP DRAWING ROOF WITH COMPONENT CUT SHEETS FOR REVIEW AND APPROVAL. 2. PROVIDE NEW ADDRESSABLE FIRE ALARM CONTROL PANEL, SIMPLEX 4010 SERIES OR EQUAL WITH ADDRESSABLE DEVICES AS INDICATED ON PLANS. SYSTEM SHALL INCLUDE LCD REMOTE ANNUNCIATOR, POWER BOOSTERS AND BATTERIES AS REQUIRED TO ACHIEVE 25% SPARE CAPACITY, AND PHONE DIALER AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. NEW AUDIO/VISUAL AND VISUAL ONLY DEVICES SHALL BE WHITE WITH RED LETTERS. 1ST FLOOR 3. FIRE ALARM SYSTEM SHALL BE IN CONFORMANCE WITH THE LATEST TUKWILA FIRE DEPARTMENT RULES AND REGULATIONS. 4. PROVIDE POWER BOOSTERS AND BATTERIES SIZED TO ACCOMMODATE NOTIFICATION APPLIANCE QUANTITIES ILLUSTRATED WITH 25% ADDITIONAL SPARE CAPACITY. 5. PROVIDE UL LISTED LOCKING DEVICE FOR POWER SOURCE CIRCUIT BREAKER AND LABEL AS " FIRE ALARM CONTROL CIRCUIT" IN THE PANELBOARD DIRECTORY. 6. VISUAL APPLIANCES WITHIN SAME ROOM OF FIELD OF VIEW SHALL BE SYNCHRONIZED. 7. STROBES INDICATED AS 15cd OR 30cd SHALL BE DUAL RATED 15/75cd OR 30/75cd 8. CONTRACTOR SHALL FURNISH FOR RECORD FINAL APPROVED SHOP DRAWING'S TO BUILDING MANAGEMENT COMPANY AND ENGINEER. 9. ALL FIRE ALARM SYSTEM RACEWAY SIZES AND CIRCUITRY REQUIREMENTS SHALL BE IN ACCORDANCE WITH FIRE ALARM MANUFACTURER'S RECOMMENDATIONS, NFPA 72, ALL CODES WHICH MAY APPLY, AND THE LOCAL FIRE DEPARTMENT. 10. COORDINATE CONNECTION TO BUILDING SECURITY COMPANY SYSTEM(A CITY OF TUKWILA-APPROVED UL CENTRAL STATION). ALARM ON FIRE ALARM SYSTEM SHALL CONTACT BUILDING SECURITY COMPANY AND FIDELITY SECURITY COMPANY VIA MODEM CONNECTION. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE A SIGN WITH 1" LETTERS THAT READS " FIRE ALARM" OR " FIRE ALARM CONTROC OUTSIDE ELECTRIC CLOSET DOOR, WHERE FIRE ALARM CONTROL PANEL SHALL BE LOCATED. 12. COORDINATE LOCATION AND REQUIREMENTS OF EXTERIOR BELL WITH FIRE PROTECTION ENGINEER PRIOR TO BID. FIRE ALARM RISER DIAGRAM \-\ CODE COMPLIANCE. NFPA 70 - NEC - City Of Tuiolia N.T.S. _ GROUND BUS YES 100% _ FEED THRU LUGS YES _ 200% NEUTRAL YES DESCRIPTION OF LOAD AMPS/ POLES CIR. PRIMARY AMPS EF 20/1 2 -3 EF -1 & EF 20/1 4 -2 EXTERIOR SIGNAGE 20/1 6 208/120V OVERCURRENT PROTECTION EXTERIOR SIGNAGE 20/1 8 5 #2/0 & 1 #4G. IN 2 1/2 "C. SPARE 20/1 10 SPARE 20/1 12 SPARE 20/1 14 SPARE 20/1 16 SPARE 20/1 18 20/1 20 SPARE SPARE 20/1 22 SPARE 20/1 24 SPARE 20/1 26 SPARE 20/1 28 SPARE 20/1 30 SPARE 20/1 32 SPARE 20/1 34 SPARE 20/1 36 SPARE 20/1 38 SPARE 20/1 40 SPARE 20/1 42 TOTAL KVA- 6.39 TOTAL AMPS- 17.75 PANELBOARD SCHEDULE PANEL R21A (SECTION 2) - NEW MAIN CIR. 43 AMPS/ POLES 20/1 VOLTS AMPS PH /WIRE 208Y/120V 225A BUS 3/4 MOUNT. AIC LOC. SURFACE 10 KAIC ELEC. ROOM GROUND BUS YES 100% FEED THRU LUGS NO 200% NEUTRAL YES DESCRIPTION OF LOAD LOAD kVA LOAD BY PHASE, kVA A B C LOAD kVA SPARE 0.00 45 20/1 SPARE 47 49 51 53 55 57 20/1 20/1 20/1 20/1 20/1 20/1 SPARE SPARE SPARE SPARE 0.00 DESCRIPTION OF LOAD SPARE AMPS/ POLES CIR. 20/1 44 SPARE 20/1 46 SPARE 0.00 0.00 SPARE 0.00 SPARE SPARE SPARE 20/1 20/1 20/1 48 50 52 54 SPARE 59 61 20/1 20/1 SPARE 0.00 0.00 SPARE SPARE 20/1 20/1 56 58 SPARE 63 65 67 69 71 73 75 77 79 81 20/1 20/1 20/1 20/1 20/1 SPARE 0.00 SPARE SPARE 20/1 20/1 60 62 SPARE 0.00 SPARE SPARE 0.00 SPARE 0.00 SPACE 0.00 SPACE SPACE 0.00 83 SPACE SPACE 0.00 SPARE SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE 20/1 20/1 20/1 20/1 0.00 SPACE SPACE 64 66 68 70 72 74 76 78 80 82 TOTAL kVA BY PHASE - (BOTH SECTIONS) TOTAL kVA BY PHASE - 0.00 SPACE 2.75 1.76 TOTAL KVA- (BOTH SECTIONS) TOTAL KVA- TOTAL AMPS- 0.00 6.39 84 M: \2008 \20080076 - Fidelity Seattle Base Building \Electrical \20080076 E09.01 ELEC SCHEDULES.dwg [30x42] May 30, 2008 - 10:06am slunn PAD MOUNTED UTILITY XFMR PROVIDED BY PSE SEE NOTE 7 - REFER TO BOLLARD DETAIL ON E08.01 FOR ADDITIONAL INFORMATION NEW UTILITY METER SOCKET AND CT SEE NOTE 5 MEL GRADE WP SEE NOTE 6 INCOMING UTILITY SERVICE BY PSE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL EXCAVATION REQUIREMENTS FOR TRANSFORMER PAD WITH PSE PRIOR TO BID. SEE DETAIL EG001 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION 4#500KCMIL IN 4" C. TYPE USE. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT RUN IN FIELD PRIOR TO WORK. FIDELITY ELECTRIC CLOSET SEE DETAIL EG001 ON DRAWING E08.01 FOR ADDITIONAL INFORMATION 4 NEW FLOOR MOUNTED 45KVA TRANSFORMER POWER RISER NOTES: 1. REFER TO DRAWING E01.01 FOR LEGEND, SYMBOLS AND GENERAL NOTES THAT MAY PERTAIN TO THIS DRAWING. 2. THIS DRAWING IS INTENDED TO ILLUSTRATE MAJOR EQUIPMENT AND REQUIRED INTERCONNECTIONS. REFER TO THE FLOOR PLANS FOR EXACT LOCATIONS AND THE SPECIFICATIONS FOR ADDITIONAL INSTALLATION REQUIREMENTS. 3. REFER TO THE DRY TYPE TRANSFORMER SCHEDULE(S) FOR CONDUCTOR AND RACEWAY REQUIREMENTS NOT SPECIFICALLY NOTED ON TRANSFORMER PRIMARY AND SECONDARY CONNECTIONS. 4. THE SERVICE AND ALL SEPARATELY DERIVED SYSTEMS SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 250 OF THE NEC. BOND ALL ELECTRICALLY CONDUCTIVE MATERIALS SUCH AS METAL PIPING SYSTEMS AND STRUCTURAL STEEL TO THE GROUNDING SYSTEM. REFER TO DETAILS FOR ADDITIONAL INFORMATION. 5. NEW UTILITY METER SOCKET WITH PROVISION FOR TEST SWITCH AND 400A CT CABINET. PROVIDE 1" LETTERS ON A PERMANENT LABEL INDICATING ADDRESS ON METER SOCKET. EC SHALL PROVIDE THE SOCKET AND CT ENCLOSURE. COORDINATE WITH PSE (PUGET SOUND ENERGY) PRIOR TO WORK FOR EXACT METER SOCKET AND CT CABINET REQUIREMENTS. ALL EQUIPMENT SHALL BE APPROVED BY PSE PRIOR TO PURCHASE. 6. ELECTRICAL CONTRACTOR SHALL PROVIDE RIGID GALVANIZED CONDUIT SWEEP AND SCHEDULED 80 PVC EXPANSION COUPLING. ROOF 1ST FLOOR PARTIAL ELECTRICAL RISER DIAGRAM N.T.S. KNOX BOX AND BEACON LOCATED OUTSIDE. COORDINATE LOCATION WITH FIRE LOCAL FIRE DEPARTMENT. SEE NOTE 12] ocs FACP REFER TO NOTE #2,11 1#6 IN 3/4"C. ELECTRIC ROOM R21A-7 REFER TO NOTE #5 REFER TO NOTE #4 (2) DEDICATED PHONE LINE, REFER TO NOTE #10 TENANT SPACE NOTES: 1. THIS DRAWING IS INTENDED TO ILLUSTRATE MAJOR EQUIPMENT AND THE INTENDED INTERCONNECTIONS. REFER TO THE FLOOR PLAN FOR EXACT LOCATIONS AND QUANTITIES OF DEVICES. REFER TO THE MANUFACTURER'S WIRING DIAGRAMS FOR INTERCONNECTION REQUIREMENTS. INTERCONNECTION DETAILS SHALL BE INCLUDED IN THE SHOP DRAWING ROOF WITH COMPONENT CUT SHEETS FOR REVIEW AND APPROVAL. 2. PROVIDE NEW ADDRESSABLE FIRE ALARM CONTROL PANEL, SIMPLEX 4010 SERIES OR EQUAL WITH ADDRESSABLE DEVICES AS INDICATED ON PLANS. SYSTEM SHALL INCLUDE LCD REMOTE ANNUNCIATOR, POWER BOOSTERS AND BATTERIES AS REQUIRED TO ACHIEVE 25% SPARE CAPACITY, AND PHONE DIALER AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. NEW AUDIO/VISUAL AND VISUAL ONLY DEVICES SHALL BE WHITE WITH RED LETTERS. 1ST FLOOR 3. FIRE ALARM SYSTEM SHALL BE IN CONFORMANCE WITH THE LATEST TUKWILA FIRE DEPARTMENT RULES AND REGULATIONS. 4. PROVIDE POWER BOOSTERS AND BATTERIES SIZED TO ACCOMMODATE NOTIFICATION APPLIANCE QUANTITIES ILLUSTRATED WITH 25% ADDITIONAL SPARE CAPACITY. 5. PROVIDE UL LISTED LOCKING DEVICE FOR POWER SOURCE CIRCUIT BREAKER AND LABEL AS " FIRE ALARM CONTROL CIRCUIT" IN THE PANELBOARD DIRECTORY. 6. VISUAL APPLIANCES WITHIN SAME ROOM OF FIELD OF VIEW SHALL BE SYNCHRONIZED. 7. STROBES INDICATED AS 15cd OR 30cd SHALL BE DUAL RATED 15/75cd OR 30/75cd 8. CONTRACTOR SHALL FURNISH FOR RECORD FINAL APPROVED SHOP DRAWING'S TO BUILDING MANAGEMENT COMPANY AND ENGINEER. 9. ALL FIRE ALARM SYSTEM RACEWAY SIZES AND CIRCUITRY REQUIREMENTS SHALL BE IN ACCORDANCE WITH FIRE ALARM MANUFACTURER'S RECOMMENDATIONS, NFPA 72, ALL CODES WHICH MAY APPLY, AND THE LOCAL FIRE DEPARTMENT. 10. COORDINATE CONNECTION TO BUILDING SECURITY COMPANY SYSTEM(A CITY OF TUKWILA-APPROVED UL CENTRAL STATION). ALARM ON FIRE ALARM SYSTEM SHALL CONTACT BUILDING SECURITY COMPANY AND FIDELITY SECURITY COMPANY VIA MODEM CONNECTION. 11. ELECTRICAL CONTRACTOR SHALL PROVIDE A SIGN WITH 1" LETTERS THAT READS " FIRE ALARM" OR " FIRE ALARM CONTROC OUTSIDE ELECTRIC CLOSET DOOR, WHERE FIRE ALARM CONTROL PANEL SHALL BE LOCATED. 12. COORDINATE LOCATION AND REQUIREMENTS OF EXTERIOR BELL WITH FIRE PROTECTION ENGINEER PRIOR TO BID. FIRE ALARM RISER DIAGRAM \-\ CODE COMPLIANCE. NFPA 70 - NEC - City Of Tuiolia N.T.S. ELLA- OH OFidelity INVESTMENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS Issue 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210-1964 T 617-345-9885 F 61 7-345-4226 Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL 1 Project Name Fidelity Investor Center - SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name IDescription ELECTRICAL SCHEDULES I Scale NTS E09.01 02006 Gensler RECEIVED JUN 06 2008 PERMITCENTE- K -RATED 3 PHASE DRY TYPE TRANSFORMERS TAG KT4 RATED KVA 45 PRIMARY AMPS 54 480V OVERCURRENT PROTECTION 80A -3P 480V FEEDER 3 #3 & 1 #8G. IN 1 1/4 "C. SECONDARY AMPS 125 208/120V OVERCURRENT PROTECTION 150A -3P 208/120V FEEDER 5 #2/0 & 1 #4G. IN 2 1/2 "C. NOTES: 1. CONDUCTOR SIZES ARE THE MINIMUM ALLOWED BASED UPON NEC TABLE 310.16 WITH THREE OR FOUR CURRENT CARRYING CONDUCTORS PER RACEWAY IN AN AMBIENT NOT TO EXCEED 30 DEGREES C. 2. RACEWAY SIZES ARE THE MINIMUM ALLOWED BASED UPON NEC TABLE 01 FOR THHN /THWN CONDUCTORS IN EMT, FLEXIBLE METAL CONDUIT OR LIQUIDTIGHT. 3. SECONDARY GROUNDING CONDUCTORS ARE SIZED IN ACCORDANCE WITH NEC TABLE 250.66 TO ACCOMMODATE REQUIREMENTS IN NEC 250.30 FOR SEPARATELY DERIVED SYSTEMS. BOND THE TRANSFORMER CASE AND THE GROUNDED CONDUCTOR (NEUTRAL) TO THE EQUIPMENT GROUNDING CONDUCTOR AND ALL REQUIRED GROUNDING ELECTRODES. 4. SECONDARY CONDUCTORS SHALL NOT EXCEED 25' FROM THE TRANSFORMER TERMINALS TO THE SECONDARY OVERCURRENT PROTECTION DEVICE IN ACCORDANCE WITH NEC 240.21(C)(6). ELLA- OH OFidelity INVESTMENTS Seattle Branch 304 Strander Blvd. Seattle, WA 98188 Gensler ENGINEERS Issue 01 133 Federal Street 5th Floor Boston MA 02110 Telephone 617.292.4400 Facsimile 617.292.4401 Richard D. Kimball Company, Inc Seaport Center 70 Fargo Street Suite 801 Boston, MA 02210-1964 T 617-345-9885 F 61 7-345-4226 Date & Issue Description By 06/02/08 SJ ISSUE FOR CONSTRUCTION Check SL 1 Project Name Fidelity Investor Center - SEATTLE BRANCH 1 Project Number 20080076 1 CAD File Name IDescription ELECTRICAL SCHEDULES I Scale NTS E09.01 02006 Gensler RECEIVED JUN 06 2008 PERMITCENTE-