Loading...
HomeMy WebLinkAboutPermit EL08-0725 - INTEGRAThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL08 -725 Integra 12783 Gateway Drive RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit 9 Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. INTEGRA 12783 GATEWAY DR CANCELLED ELO8-725 CityOf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -725 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Tenant: Name: INTEGRA Address: 12783 GATEWAY DR #6 , TUKWILA WA Owner: Name: RREEF AMERICA REIT II CORP/ Phone: Address: PO BOX 4900 #207 , SCOTTSDALE AZ Contact Person: Name: MARC SCHMOLL Phone: 206 - 300 -7544 Address: 12500 AURORA AVE N , SEATTLE WA Contractor: Name: COCHRAN INC Address: PO BOX 33524 , SEATTLE WA Contractor License No: COCHRI *088JS Phone: 206 367 -1900 Expiration Date: 04/11/2010 DESCRIPTION OF WORK: 36 NEW LIGHT FIXTURES, 6 DOWN LIGHTS, CODE REQUIRED LIGHTING CONTROL, 29 RECEPTACLES, 4 CIRCUITS FOR CUBICALS, WIREMOLD FOR WAREHOUSE AND 4 CIRCUITS FOR 4 NEW OFFICES Value of Electrical: $59,778.00 Fees Collected: $1,022.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: At Date: (I —Cr 06 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc o work. I am authorized to sign and obtain this electrical permit. Signature: Date: 044. Print Name: G1 V. L.'. /� i �/V L1) l I 6 - ? -U7 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -725 Printed: 06-09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Tenant: INTEGRA PERMIT CONDITIONS Permit Number: EL08 -725 Status: ISSUED Applied Date: 06/09/2008 Issue Date: 06/09/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: ot v (._ 51h14,‘_011 Date: r r doc: Cond -Elec EL08 -725 Printed: 06-09 -2008 "SA X606 (76C CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. El.-0 5-1 as-- Project No. ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION // King Co Assessor's Tax No.: )--7 f (000 - 00 GO O Site Address: dN 7 d 3 A �e V� y7 Tenant Name: -h ¥rex TP GDwf Property Owners Name: Mailing Address: Suite Number: Floor: New Tenant: eeS Yes El ..No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: I V l G rC g G vl W1.0 t Day Telephone: ° 75-4/ y Mailing Address: / a6 06° gitltt ('t Ave. T f /� V wq" 93j I ?? ity State Zip O E -Mail Address: /'AAM`'!�[. ! 4✓me L L COc; �RA�1� N/� • �• �`l Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: GO A tr.,. £ L ec -t r2 - /534v 4-atom Ave P. 5,zaii --le- vvA- 2kG3 1,� City State Zip el Contact Person: A i S� v I Wt.a 1 ( , 11 Day Telephone: �6 – 300— 7 q E -Mail Address: 1/Y156 4" LJL @ 64061 (AA) Ti1UC, CL7 ax Number: 2t 6. 3 ? 3/ 7 7 Contractor Registration Number: 0.7C (4 12-i sl- DB 83 S Expiration Date: Valuation of Project (contractor's bid price): S / 778' 1 Scope of Work (please provide detailed information): �� IAA iv ;dims-, 6 AAA". l 5 1 _ e e r3ti ctrl k- 1 z 9 Pee- ep4-4s, 1is. Y Cr�� &,tr ,CLcr e s W k t - e - v h - 0 I 0 - war -e (tv J Se - c f 4 [ , Cl ',Lt. to Will service be altered? ❑ Yes ,4 No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel X51 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ,r Seattle City Light 1-1 Wpplications\Ponns- Applications On Line\4 -2007 - Electrical Permit Application doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions 510.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Y' `C■ r (_ 5 c Vl Vt^ 0 t Mailing Address: %tea B 4‘APD is Day Telephone: City Date: CJ - O ^e.f" 2_06- 10d -- >5--yy v/A- 98-33 State Zip Date Application Accepted: Date Application Expires: Staff Initials: H :WpplicationsWorns•Applications On lin64 -2007 - Electrical Permit Application doc bh Page 2 of 2 PROJECT: Integra Panel 6A Center - B6 & B9 - Tukwilla, WA REV. NO. LOCATION: Bldg. 6 DATE: 6/6/08 REV. DATE: FED FROM: Source via xfmr. roc ran' ADDRESS: Gateway Corporate JOB NO: 260608 Ckt No. LOAD DESCRIPTION Note BUS kVA OCPD LOAD kVA DESCRIPTION A B C Amp / P Rec ! Heat . Motor Ltg Equip Kit 225 AMPS 1 208Y/120v, 3ph-4w !, 10,000 A.I.C. 1 ❑ MLO 1 Rec -Open Office 2, Office 9 1.1 20 /1 1.1 t 3 Rec -Open Office 2, Office 8, Ware House 5, RR Corr. 1.1 20 /1 1.1 5 Rec -RR 1 ■ r 0.2 20 /1 20 /1 0.2 0.2 7 Red RR 6 J Main OCPD g Rec -Office 5 0.7 20 /1 0.7 ❑ Subfeed Lugs or OCP[ ❑Through Feed Lugs ❑ Top Feed ❑ Bottom Feed ❑ Surface ❑ Flush ❑ Door -in -Door 11 Rec -Offices 10, 11, 12 1.6 20 /1 1.6 J 13 Rec -Conf. 13, Office 14, Open Office 2 20 /1 1.1 15 Rec -Open Office 2, Recep 1, Office 3 1.3 20 /1 1.3 17 Rec -Lunch Rm 4, House Keeping r ®- 1.5 0.4 20 /1 20 /1 0.4 MI- 1.5 19 Rec -Lunch Rm 4, Appliance 1 21 Rec Lunch Rm 4, Appliance 20 11 1.5 ■ 1 23 a 25 i27 29 Rec -Lunch Rm 4, Appliance 1.5 20 /1 20 /1 1.5 Spare -- Spare - -- _, 20 /1 20 11f 2011 20 /1 Spare ■ Ground Bus ❑ Isolated Ground Bus ❑ 200% Neutral ❑ Copper Bus ❑ NEMA 3R Enclosure 31 p 33 . 3 5 Spare Spare i Spare 20 /1 ^ 37 39 J 41P 2 4 6 Spare 20 /1 Tl_ i l Spare_ I 20 /1 20 /1 �... - Spare _ - Rec- Cubicles Open Office 2 _ T 1.1 ! 3 1.1 1.1 20 /1 20 /1 20 /1 _ 20/1_ 20 _ 11 20 /1 20 /1 14 1.1 1.1 1_.1 1 1 1.1 171 _ ,L _ i_ 1 �_ 1 : _ _ ' _-I : I KVA KVA ^i CONN DEM Rec 24.8 17.4 ' Heat . Motor Ltg Equip 4.5 4.5 " Kit Total 29.3 21.9 Total Rec - Cubicles Open Office 2 1.1 _ 1.1 Rec - Cubicles Open Office 2 8 Rec- Cubicles Open Office 2 1 1.1 ! JI 1 I ' _ 10 Rec - Cubicles Open Office 2 1.1 12 Rec- Cubicles Open Office 2 14 Rec- Cubicles Open Office 2 16 Rec - Cubicles Open Office 2 1.1 20 /1 1.1 I MI II II 18 Rec- Cubicles Open Office 2 1.1 20 /1 1.1 1 20 Rec - Cubicles Open Office 2 1.1 1 1.1- 20 /1 1.1 -, 22 Rec - Cubicles Open Office 2 20 /1 1.1 24 Rec- Cubicles Open Office 2 1.1 20 /1 20 /1 1.1 1.1 26 Rec- Cubicles Open Office 2 1 -1 28 Rec - Cubicles Open Office 2 1.1 20 /1 1.1 Amps CONN DEM PHA 86 64 PHB 83 62 PHC 75 56 Rec - Cubicles Open Office 2 1.1 20 /1 1.1 III 32 Rec Cubicles Open O30 Office 2 1.1 20 1t 1.1 34 Spare 20 /1 -- 36 Spare 20 /1 38 Spare 20 /1 40 Spare 20 /1 42 Spare 20 /1 NOTES . Cochran. h.,. 1. Existing Panel. 2. Served from an existing 75kVA transformer. L _- . City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director July 28, 2008 Marc Schmoll Cochran Electric 12500 Aurora Avenue N PO Box 33524 Seattle, WA 98133 RE: Permit Fee Refund Dear Mr. Schmoll: Enclosed is a check in the amount of $817.60 for the permit fee paid at the time of permit issuance for the project located at 12783 Gateway Drive, #6, Tukwila, Washington. The scope of work under this permit was cancelled. If you have any questions, please feel free to contact our office at 206 -431 -3670. Sincerely, Brenda Holt, Permit Coordinator encl xc: Permit No. EL08 -725 H:\Documents\Letters \EL08 -725 - refund Ietter.doc bh 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 CITY OF TUKWILA, WA 98188 -2544 ACCOUNTS PAYABLE CHECK NO. INVOICENUMBER _. '' - t)A15?'; - _- P.Q. NUMBER ' ' DESCRIPTION : `' - - AMOUNT 072108302 07/16/2008 80% REFUND EL08 -725 817.60 PLEASE DETACH BEFORE DEPOSITING R...a.Y ,I ... TjH H I SI DOGUME411-eHA- AaCOLOREDrB,AC,KG,ROU; I I�TE BA'CKGRQUN01;3;jtfir. ill PAY TO THE ORDER OF CITY OF TUKWILA 6200 Southcenter Boulevard Tukwila WA 98188 -2544 PAYABLE THROUGH U.B. BANK 151 Allover Pads East Tukwila, WA 98188 19-10 1250 :I=„nec a .. ' .? { k8 4{: 14.1,� 4 �.11 A�7_, -' �_1°kr, _ 1141 ;%"- 008377 07/21/2008 817.60 Eight Hundred Seventeen Dollars and Sixty Cents COCHRAN INC PO BOX 33524 SEATTLE, WA 98133 Q ;THE'BAC,K OF THIS:',DOCUMENT,HASAWAR TIEI, CIAi,WATERMAR,Kt'HOLDIAT';AN ANGLE ;T City of Tukwila Permit Center Memo July 10, 2008 To: Laurie Anderson From: Brenda Holt Re: EL08 -725 VlAk Please refund $817.60 which equals 80% of the permit fee paid for the above reference permit. The scope of work under this permit has been cancelled. Please make the check out to the following and I will forward it to them: Cochran Electric PO Box 33524 Seattle, WA 98133 Xc: File No. EL08 -725 H:\Documents\Letters\ELO 8-725 - refund memo.doc bh car ran July 7, 2008 RECEIVED `JUL 032008 cosawww 1umaton Bob Benedicdo City of Tukwila Chief Electrical Inspector Tukwila, Washington Re: Permit Number EL08 -725 Dear Bob: I would like to request a refund on permit EL08 -725 for the following reasons; on 6 -09 -08 we had a verbal commitment from Reef Property Management for two tenant improvements for Integra Telecom located at 12783 Gateway Dr #6, Tukwila WA. Since that time without out any notice Integra Telecom has backed out of their leased space and therefore will not be doing any tenant improvements to the above stated location, however, they have agreed to some tenant improvements at their current location, 13035 Gateway DR #9, Tukwila WA., which I have pulled another permit for (EL08 -722). Please do not hesitate to contact me with any questions or concerns. Your patience and cooperation in this matter is greatly appreciated. Thank you Marc Schmoll Cochran Electric 206 - 300 -7544 ELECTRICAL CONSTRUCTION ELECTRICAL ENGINEERING ELECTRICAL SERVICE vi ox V2 CANCEL Etog -'7z5 481, cs141? 6o7 OF MgVur rEe, 12500 Aurora Ave North PO Box 33524 Seattle. WA 98133 • ASTRA WOMEN'S BUSINESS A L L I A N C E Phone 206 -300 -7544 Fax 206 -368 -3197 E -mail mschmoll@cochraninc.com City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2716000060 Address: 12783 GATEWAY DR TUKW Suite No: Applicant: INTEGRA RECEIPT Permit Number: EL08 -725 Status: PENDING Applied Date: 06/09/2008 Issue Date: Receipt No.: R08 -02025 Payment Amount: $1,022.00 Initials: WER Payment Date: 06/09/2008 11:23 AM User ID: 1655 Balance: $0.00 Payee: COCHRAN TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13356 1,022.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,022.00 Total: $1,022.00 3436 06/09 9711 TOTAL 1022.00 doc: Receiot -06 Printed: 06 -09 -2008 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License COCHRI *088JS Licensee Name COCHRAN INC Licensee Type ELECTRICAL CONTRACTOR UBI 578042134 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 33524 Address 2 City SEATTLE County KING State WA Zip 981330524 Phone 2063671900 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/10/1992 Expiration Date 4/11/2010 Suspend Date Separation Date Parent Company Previous License COCHREC450BK Next License Associated License COCHRRL259R2 Electrical Administrator Information License COCHRRL259R2 Name COCHRAN, ROBERT L Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date COCHRAN, ROBERT L 01/01/1980 COCHRAN, GORDON W 01/01/1980 COCHRAN - OLSEN, LEEANN G 01/01/1980 COCHRAN, ROBERT L AGENT 01/01/1980 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= COCHRI *088JS 06/09/2008