Loading...
HomeMy WebLinkAboutPermit D10-009 - HIGH FIVE SPORTSWEAR - STORAGE RACKSHIGH FIVE SPORTSWEAR 18200 SEGALE PK DR B D10 -009 Citylif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 3523049119 Address: 18200 SEGALE PARK DR B TUKW Suite No: Permit Number: D10 -009 Issue Date: 02/18/2010 Permit Expires On: 08/17/2010 Tenant: Name: HIGH FIVE SPORTSWARE Address: 18200 SEGALE PK DR B , TUKWILA WA Owner: Name: LA PIANTA LLC Address: PO BOX 88028 , TUKWILA WA 98138 Phone: Contact Person: Name: DAVID LITTLE Address: 9883 40 AV S , SEATTLE WA 98118 Phone: 206 394 -3306 Contractor: Name: ENGINEERED PRODUCTS Address: 18271 ANDOVER PK W , TUKWILA WA 98188 Phone: 206- 394 -3300 Contractor License No: ENGINPC931CO Expiration Date: 02/20/2011 DESCRIPTION OF WORK: INSTALLATION OF 84 BAYS OF PALLET RACK WITH ANCHORING PER ENGINEER. Value of Construction: $0.00 Fees Collected: $622.10 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0025 * *continued on next page ** doc: IBC -10/06 D10 -009 Printed: 02 -18 -2010 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D1O -009 Issue Date: 02/18/2010 Permit Expires On: 08/17/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: ulIir—)r‘L Date: V V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe construction or the perform Signature: Print Name: ( s not pres fw v� o give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development pe . 't. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -009 Printed: 02 -18 -2010 Parcel No.: 3523049119 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18200 SEGALE PARK DR B TUKW HIGH FIVE SPORTSWARE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10-009 ISSUED 01/15/2010 02/18/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Cond -10/06 D10 -009 Printed: 02 -18 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Fire extinguishers shall not be obstructed or obscured from view. hi rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. ff the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point m an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established m section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 22: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes m case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 23: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 24: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) doc: Cond -10/06 D10 -009 Printed: 02 -18 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 26: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 27: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 28: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose stations and curtain boards may be required by Table 2306.2 of the International Fire Code. Contact the Tukwila Fire Prevention Bureau for further information. (IF THERE IS EXISTING HIGH -PILED RACK STORAGE WHICH EXCEEDS 12,000 SQUARE FEET OR THE INSTALLATION OF NEW RACK STORAGE CAUSES THE ENTIRE HIGH -PILED STORAGE AREA TO EXCEED 12,000 SQUARE FEET THEN SMOKE AND HEAT REMOVAL IS REQUIRED PER INTERNATIONAL FIRE CODE TABLE 2306.2.) 29: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 30: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 33: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -009 Printed: 02 -18 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the p ormance of work. Signature: Print Name: r,( /(d @i Date: ( ) doc: Cond -10/06 D10 -009 Printed: 02 -18 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup: ip\rtr.ci. !Owl la. Iva. us Building, Permit No. • Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: ,072.2:191–( —1, (i-1 Site Address: %gGCXS Se 4 /(_ 2-4 sOnC, Suite Number: Floor: 1 Tenant Name: / / • i / - l , G . S d /IIII.�. t / • • New Tenant: ❑ Yes ( ..No t . Property Owners Name Mailing Address: /y ) Sec. (C 177 0/1'4_ '4 � ALL % City State 7 rie7 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: (c.u.� /» Mailing Address: E -Mail Address: C141/ ep6 Pi/Oct . LOng GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4)� for Plumbing and Gas Piping (pg 5)) 1 �n CJ I L L Greet roA„. f. Day Telephone: 73067 / St� ilk 9'6"/ City State Zip Fax Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: (/U inn ef co 9 613 'id 5 , Pile, v-91 City `T L''I caw u i rd Z. eicJ - State Zip Day Telephone: , - 794 " 33D4, Fax Number: '20(6 Expiration Date: ARCHITECT OF RECORD - All plans-must be wet stamped by Architect of Record Company Name: dv lt'S Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: 5 f rtt.I -utiG I LovtLe p k 2oo ,VV scA,> 6,,. sr. E -Mail Address: l\L !I e/$LG(i S / it r A nc. kt: „„ C I- 92.w7 State Zip H:\Appltcations \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh City Day Telephone: 7/41– 4032 –7 3 i) Fax Number: 7/"/ – (32. - -77 63 Page 1 of 6 ow' • • BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ ��' Existing Buildin Valuation: $ rbS Scope] _Lock Work (please provide detailed information): ^ck 1 / ( tL )t�,� `S 4, £ L - �1v� e �e vrt+ sii Lam, `tr[ c., /-,vim . Q (/ Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IN Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Apphcation.doc Revised: I -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IN Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Apphcation.doc Revised: I -2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O Signature: Print Name: W -R AUTHORIZED AGENT: e o 1: 141(_. Mailing Address: S 3 40% ALA. ? Date: Day Telephone: v SS /ity City State Zip Date Application Accepted: O ���� Date Application Expires: I ��� J Staff Initials: it „6..."--„,/ H:\Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1.2009 bh Page 6 of 6 Parcel No.: Address: Suite No: Applicant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3523049119 18200 SEGALE PARK DR B TUKW HIGH FIVE SPORTSWARE RECEIPT Permit Number: Status: Applied Date: Issue Date: D 10 -009 ISSUED 01/15/2010 02/18/2010 Receipt No.: R10 -01045 Initials: User ID: Payee: WER 1655 Payment Amount: $63.00 Payment Date: 06/11/2010 01:29 PM Balance: $0.00 DAVID LITTLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 02586C ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts BUILDING INVESTIGATION 000.322.800 Total: $63.00 63.00 doc: Receiot -06 Printed: 06 -11 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049119 Permit Number: D10-009 Address: 18200 SEGALE PARK DR B TUKW Status: APPROVED Suite No: Applied Date: 01/15/2010 Applicant: HIGH FIVE SPORTSWARE Issue Date: Receipt No.: R10 -00280 Payment Amount: $378.80 Initials: WER Payment Date: 02/18/2010 01:47 PM User ID: 1655 Balance: $0.00 Payee: DAVID LITTLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 04562C ACCOUNT ITEM LIST: Description 378.80 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 374.30 640.237.114 4.50 Total: $378.80 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -18 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http.: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049119 Permit Number: D10-009 Address: 18200 SEGALE PARK DR B TUKW Status: PENDING Suite No: Applied Date: 01/15/2010 Applicant: HIGH FIVE SPORTSWARE Issue Date: Receipt No.: R10 -00064 Payment Amount: $243.30 Initials: JEM Payment Date: 01/15/2010 12:30 PM User ID: 1165 Balance: $378.80 Payee: DAVID LITTLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 01572A ACCOUNT ITEM LIST: Description 243.30 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 243.30 Total: $243.30 PAYMENT RECEIVED doc: Receiot -06 Printed: 01 -15 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0,0-d�t Proj � f; � � spa , � s Type of Inspection: t A... e.r c. • ; ut14 G Address: (L 1.66 5 G R Date Ile_df`\ r &-J E1'4 Special Instructions: e, ..- \N Date Wanted: / lD - rimy 2c — ( p.m. Requester: Phone No: A4 2S— 21g -31o& Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: P p5 M C C 6-Dm lot/ re e.9 Insperctor: Date:to -24-(3 ❑ $60.00 REINSPECTION FEE REQl1IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit dv. 0.--0J9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project:, tt• (�tf^ F, .,f Sp�iTJ Type of Inspection: 6dt,aPry.C'ke c< L, Address: 1 1 k2vo .CC eAQ Date Called: Special Instructions: 'r,." Date Wanted: a.m. 9 23-id Requester: Phone No: zi 2S- 2 (�1 �y -3IvE' ❑ Approved per applicable codes. • orrections required prior to approval. ". COMMENTS: (J7NZF..-.2 i�<<�Sue -P f.7 1.j i�C�! F< /S /JJ%2 (�1./ PJfJ..J) j .11-6 1,_A,A er V tit C 6 ( \' L7 / . y i A i Inspe( tor: Date: co El $60.00 REINSPECTION FEE REOUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: a �..� —• - ,a +�rr� . ,.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 11' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project /‘ /6/ r .S,avi 'S Type of Inspection: ��r'/-GP " 1 y 47 /A/, Addr ss: /BZ 'c CE �./! &ve Date Called: v,? — r3 . Special Instructions: 44147 _ Date Wanted: — 4o - /d p.m. Requester: d c /o►v 14e Cf Phone No: / r5Ci0— 5'75 -/605 ;,, y - 0 Approved per applicable codes. 4/1Corrections required prior to approval. COMMENTS: M'r ?e /'y ;,, y - I - Amf f Dat / 0 REINSPECTION FEE - QUIR . Prior to inspection, fee must by at 6300 Southcenter Blv'.., Sui, - 100. Call to schedule reinspection. Date: ._.,._ .ft.ae _ _ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Old -001 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prbj ect: IM+ Je Sper1 €.JAfe Type o Inspec 'on: t bu. duet Add'essia d s / e i D Date Called: Special Instructions: �,i Q �i� 0 ! < <P.T- l Date Wanted: , a.m. Requester: Phone 4? -C -21 ?'31 OE‘ l � k) Approved per applicable codes. Corrections required prior to approval. COMMENTS: F----Aprvikt4Q ED ere i-irtkr-,g<7 ,„..1.) (o•rc, Sg€ r eN JA L L� I"� .- Strom c.5-1 Ai gbZI7q ID Eirt&OXV 4- 46-4 -1 1.-- i 511., k Nki 5 feg a S I sp ctor: 1 0.00 REINSPECTI41 FEE REQUIRED. P for to inspection, fee must be Call to schedule reinspection. Date: 3 -�t 10 id at 6300 Southcenter Blvd., Suite 1 Receipt No.: Date: • rr+c • x Aux- •r, =�.� a. TJ r INSPECTION RECORD Retain a copy-with permit .. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 - 206575 -4407 INSPECTION NUMBER Project: /./,3/A f,;)e lip ",/s „eP,, M1 Type of Inspection: ic",2 A” "' Address: 4 q Z ao Suite #: S°, el I P4 k. h Contact Person: eloby O 7ftl Special Instructions: Phone No.: 2 ez, - f //- 61123 ® Approved per applicable codes. l l Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: ,f �1 i,,ry At. O — A / 3/-/ v Q__,t,1k Pi!e. e__ - - 1T I n l M 4- , e .., 1 5-, m1 C c424,15 j 71 t%60 1` . c......:// 1voteeeo $1,vo44 L 4P A / -",-4,10v0.4 Needs Shift Inspection: �/� Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: , Occupancy Type: • • Inspector(/4. _ki v./ • Date: 4/4-1 t d Hrs.: Y. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Calf to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form.F.P. 113 FILE COPY Permit No. St ctural ncepts ngineering 1200 N. Jefferson St, Suite F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 e -mail: mail @sceinc.net REVIEWED FOR CODE COMPLIANCE PP. fova) FEB 16 2010 Project Name : HIGH FIVE SPORTSWEAR Project Number : K- 011210 -1 Date : 01/12/10 Street Address : 18200 SEGALE PARK DRIVE #B City /State : TUKWILA, WA 98188 Scope of Work : STORAGE RACKS crrONSLA JAN '1" 5 2010 PERNIRCEIdTER City of Tukwila BUILDING DIVISION EXPIRES 10/25/ 1\ 2 2010 piooO1 . Structural Concepts tjEngineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Project #: K -011210 -1 TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads 5 to 6 Column 7 Beam and Connector B to g Bracing 10 Anchors 11 Base Plate 12 Slab on Grade 13 TYPE I SELECTIVE RACK-HIGH FIVE SPORTSWEAR Page of k 1/12/2010 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.6 3x.7763 By: BOB Project: HIGH FIVE SPORTWEAR Project it K -011210 -1 Design Data 1) The analyses conforms to the requirements of the 2006 IBC and the 2002 Rack Manufacturers Institute Sepecifications for Steel Storage Racks (RMI) and the ASCE 7 -05, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy =55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy =55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The reinforced slab is 6" thick with minimum 2500 psi compressive strength. Soil bearing capacity is 1000 psf. Definition of Components Frame Height Beam A Product 1 Beam Spacing �li' Beam Length IFF Front View; Down Aisle !Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors gii—I Panel Height H Frame Depth Section A: Cross Aisle (Transverse) Frame Horizontal Brace Diagonal Brace The components herein are designed within the guidelines of the 2006 IBC and the 2002 Rack Manufacturers Institute Specifications for Storage Racks. The final design of the system is valid only with proper approval from the jurisdictional building official. TYPE I SELECTIVE RACK-HIGH FIVE SPORTSWEAR Page of l 3 1/12/2010 Structural Concepts - 4 Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tet: 714.632.7330 Fax: 714.632.7763 By: BOB Project HIGH FIVE SPORTWEAR Project #: K -011210 -1 Configuration & Summary: TYPE 1 SELECTIVE RACK 80" 240" 80" 70" 108" 240" 18" 42" 42' 47' 42" 44 -4 44" IBC 2006 Seismic Criteria * Bm LvIs Frame Depth Frame Height # Diagonals Beam Length Ss= 1.429, Fa =1 3 44 in 240 in 6 108 in Component Description STRESS Column Fy =55Ksi Hannibal IF3013- 3x3x1.3ga P =4650 ib, M =15502 in-Ib 0.77 -OK Column Backer None None None N/A Beam Fy =55Ksi Lvl 1: HMH 41140/4.125" Face x 0.075" thk Lu =108 in Capacity: 5202 Ib /pr 0.58 -0K Beam Connector Fy =55Ksi Lvl 1: 3 PIN OK I Mconn =16314 in-Ib Mcap =20306 in-Ib 0.8-OK Brace - Horizontal Fy =55Ksi Hannibal 1-1/2x1-1/2x16ga 0.15 -0K Brace - Diagonal Fy =55Ksi Hannibal 1 -1 /2x1- 1/2x16ga 0.24-0K Base Plate Fy =36Ksi 7x5x3/8 I Fotity= 5000 in-lb 0.63-0K Anchor 2 per Base 0.5" x 3.25" Embed HILTI KWIKBOLT iZ ICC ESR 1917, SPECIAL INSPEC. REQD, (T=1376 Ib) 0.36-0K Slab 6" thk x 2500 psi slab. 1000 psf Soil Bearing Pressure 0.43 -OK Level Load Per Level (P1) 1 3,000 Ib 2 3,000 Ib 3 3,000 Ib Beam Spcg 70.0 in 80.0 in 80.0 in Story Force Story Force Column Column Conn. Beam Brace Transv Longit Axial Moment Moment Connector 42.0 in 158 Ib 94 Ib 4,650 Ib 15,502 "# 16,314 "# 3 PIN OK I 42.0 in 338 Ib 201 Ib 3,100 Ib 10,184 "# 11,645 "# 3 PIN OK 42.0 in 518 Ib 308 Ib 1,550 Ib 6,164 "# 6,553 "# 3 PIN OK 42.0 in 42.0 in 18.0 in Total: 1,013 Ib 603 Ib TYPE 1 SELECTIVE RACK-HIGH FIVE SPORTSWEAR Page L of k 1/12/2010 •Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Project g: K -011210 -1 Seismic Forces Configuration: TYPE 1 SELECTIVE RACK Lateral analysis is performed with regard to the IBC 2006 Sec. 2208.1 and the 2002 RMI Sec 2.7.3. & ASCE 7 -05 sec 15.5.3 Transverse (Cross Aisle) Seismic Load DL per Lvl= 100 Ib V= Cs *Ip *(LL*0.67 +1.0 *DL) Cs * Ip= 0.1600 Ws= (0.67 * PLRF * PL) + DL V,ro,= 0.0i5 = 6,330 lb Eff Base Shear= 0.1600 Cs= 0.67 *2.5 *Ca /R >= 0.14 * 2/3 * Ss * Fa /1.4 = 0.1600 Vtransv= 0.16 * (300 Ib + 6030 Ib) = 1,013 Ib ASD Loading (RMI Sec 2.5.1.2) Level PL (Product Load) PL*0.67*PLrf 1 3,000 Ib 2,010 Ib 2 3,000 lb 2,010 Ib 3 3,000 Ib 2,010 Ib DL 100 Ib 100 Ib 100 Ib hi 70 in 150 in 230 in wi *hi 147,700 316,500 485,300 Ss= 1.429 S1= 0.489 Fa= 1.000 Fv= 1.511 Ca= 0.4 *2/3 *Ss *Fa= 0.3811 (Transverse) R= .. Ip= 1.0 PLRF= 1.0 R 157.6 Ib 337.7 Ib 517.8 Ib R *hi 11,0324 50,6554 119,094# Longitudinal (Downaisle) Seismic Load Ws= (0.67 * PLRF * PL) + = 6,330 Ib Cs * Ip= 0.67*1.2*CV /(R*TA0 = 0.0953 V„„„1= 0.015 Level PL (Product Load) 1 3,000 Ib 2 3,000 Ib 3 3,000 Ib 6,030 Ib 300 Ib W330 lb 949,500 1,013 Ib 2= 180,781 DL Eff Base Shear= .66) >= Vmin2 Vlong= Vmin7= 0.14'743 56 fe/1.4= PL*0.67*Pt.rf DL 2,010 Ib 1001b 2,010 lb 100lb 2,010 lb 100 lb 0.0953 0.0953 * (300 Ib + 6030 Ib) 603 lb ASD Loading 0.0953 hi 70 in 150 in 230 in wi *hi 147,700 316,500 485,300 T= 1.00 sec PLRF= LO (Longitudinal ) R= Cdr= 2/3 *S1 *Fv= 0.4926 A 93.8 Ib 201.0 Ib 308.2 Ib 6,030 Ib 300 lb TYPE I SELECTIVE RACK -HIGH FIVE SPORTSWEAR W=6330 Ib 949,500 Page S of l 3 603 Ib k/12/2010 �+r Vt ctural oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel_ 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORT NEAR Project #: K -011210 -1 Downaisle Seismic Loads Determine the story moments by applying Seismic Story Forces Vlong= 603 Ib Vco1= Vlong/2= 302 Ib F1= 941b F2= 201 Ib F3= 308 Ib Seismic Story Moments Configuration: TYPE 1 SELECTIVE RACK portal analysis. The base plate is assumed to provide partial fixity. Typical {tame made Tributary area ofiwo column, of rack 4ame 4 �7r ice—• {;t ;: f--1 Fir 4 ') r Mbase -max= 5,000 in-Ib < = == Default capacity Mbase -v= (Vcol *hleff) /2 = 10,251 in-lb < = == Moment going to base Mbase -eff= Minimum of Mbase -max and Mbase-v = 5,000 in-lb M 1 -1= [Vcol * hleff]- Mbase -eff = (302 Ib * 68 in) -5000 in -Ib = 15,502 in-Ib Mseis= (Mupper +Mlower) /2 Mseis(1 -1)= (15502 in -Ib + 10184 in-lb)/2 = 12,843 in-Ib Front View • Conceptual System Typical Frame made of two columns M 2 -2= [Vcol- (F1) /2] * h2 = [302 Ib - 100.5 Ib] *80 in /2 = 10,184 in-Ib Mseis(2 -2)= (10184 in -Ib + 6164 in -Ib) /2 = 8,174 in-lb aide YeLw Top View Beam to Column Elevation LEVEL 1 2 3 Summary of Forces hi 70 in 80 in 80 in Axial Load 4,650 Ib 3,100 Ib 1,550 Ib Column Moment 15,502 in-Ib 10,184 in-Ib 6,164 in-lb Mseismic Mend -fudty Mconn 12,843 in-lb 3,471 in-lb 16,314 in-Ib 8,174 in-lb 3,471 in -lb 11,645 in-lb 3,082 in-lb 3,471 in-Ib 6,553 in -Ib Beam Connector 3 PIN OK 3 PIN OK 3 PIN OK Mconn- allow(3 Pin)= 20,306 in-lb TYPE I SELECTIVE RACK -HIGH FIVE SPORTSWEAR Page (, of 1/12/2010 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Project #: K -011210 -1 Column Configuration: TYPE 1 SELECTIVE RACK Conforms to the requirements of Chapter C5 of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads. Section Properties Section: Hannibal IF3013-3x3x13ga Aeff = 0.757 in ^2 Ix = 1.320 in ^4 Sx = 0.879 in ^3 nc = 1.320 in Of= 1.67 E= 29,500 ksi Loads Iy = 0.871 in ^4 Sy = 0.574 in ^3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 70.0 in Ky = 1.0 Ly = 42.0 in Cb= 1.0 0.75 in Jcl.- Axial =P= 4,650 Ib Moment =Mhr= 15,502 in-lb (Column stresses @ Level 1)) Axial Analysis KxLx/rx = 1.7 *70 °/1.3196" KyLy /ry = 1 *4271.08" =90.2 =38.9 Fe= n^2E/(KL/r)max ^2 = 35.8ksi Pn= Aeff*Fn = 25,645 Ib P /Pa= 0.35 > 0.15 Bending Analysis Fy /2= 27.5 ksi Slc= 1.92 Fe > Fy /2 Fn= FY(1-Fy /4Fe) = 55 ksi *[1 -55 I si /(4 *35.8 ksi)] = 33.9 ksi Pa= Pn /Qc = 25645 lb/1.92 = 13,357Ib Check: P /Pa + (Cmx *Mx) /(Max *Inc) _< 1.33 P /Pao + Mx/Max 5 1.33 Pno= Ae *Fy = 0.757 in ^2 *55000 psi = 41,635 Ib Max = My /Of = 48345 in-lb /1.67 = 28,949 in-Ib lnc= {1 /[1- (0k *P /Pcr)] }^ -1 = {1 /[1- (1.92 *4650 Ib /27139 Ib)] }^ -1 = 0.67 Combined Stresses Pao= Pno /Dc = 416351b/1.92 = 21,685 Ib Myield=My= Sx *Fy = 0.879 in ^3 * 55000 psi = 48,345 in-lb Pcr= n^2EI /(KL)rnax ^2 = nA2*29500 ksi /(1.7 *70 in) ^2 = 27,1391b (4650 lb/13357 Ib) + (0.85 *15502 in- Ib)/(28949 in-Ib *0.67) = 1.03 < 1.33, OK (4650 Ib/21685 Ib) + (15502 in- lb/28949 in-Ib) = 0.75 < 1.33, OK (EQ C5 -1) (EQ C5 -2) TYPE I SELECTIVE RACK -1-1IGI1 FIVE SPORTSWEAR Page 1 of , .5 I / 1 2/20 I o 28.96 in -k 1 r tural once is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: A.A. Project: HIGH FIVE SPORTWEAR BEAM Configuration: TYPE 1 SELECTIVE RACK Dt !ERMINE ALLOWABLE MOMhN i 1APA(.i l Y Determine allowable bending moment (FMn) per section 8 of the 1996 AISI. A) Check compression flange for local budding (82.1) w= c - 2 *t -2 *r = 1.75 in - 2*0.075 in - 2*0.075 in = 1.450 in w /t= 19.33 I= lambda= [1.052/(k) ^0.5] * (w /t) * (Fy /E) ^0.5 = [1.052/(4) ^0.5] * 19.33 * (55/29500)^0.5 = 0.439 < 0.673, Flange is fully effective B) check web for local budding per section b2.3 fl(comp)= Fy *(y3/y2)= 49.12 ksi f2(tension)= Fy*(y1 /y2)= 100.881 sf Y= f2/f1 Eq. B2.3 -5 = -2.054 k= 4 + 2 *(1 -Y) ^3 + 2 *(1 -Y) Eq. B2.3 -4 = 67.08 flat depth =w= yl +y3 = 3.825 in w /t= 51 OK I= lambda= [1.052/(k) ^0.5] * (w /t) * (fl /E)^0.5 = [1.052/(67.08) ^0.5] * 3.825 * (49.12/29500) ^0.5 = 0.267 < 0.673 be =w= 3.825 in b2= be/2 bl= be(3 -Y) = 1.91 in = 0.757 bl +b2= 2.667 in > 1.2525 in, Web is fully effective Determine effect of cold worldng on steel yield point (Fya) per section A7.2 Fya= C *Fyc + (1 -C) *Fy (EQ A7.2 -1) Lcomer =Lc= (p /2) * (r + t/2) 0.177 in C= 2 *Lc/(Lf +2 *Lc) Lflange- top =Lf= 1.450 in = 0.196 in m= 0.192 *(Fu /Fy) - 0.068 (EQ A7.2 -4) = 0.1590 Bc= 3.69 *(Fu /Fy) - 0.819 *(Fu /Fy) ^2 - 1.79 = 1.427 since fu /W= 1.18 < 1.2 and r /t= 1 < 7 OK then Fyc= Bc * Fy /(R/t) ^m (EQ A7.2 -2) = 78.485 ksi Thus, Fya-top= 59.61 ksi (tension stress at top) Fya- bottom= Fya *Ycg/( -Ycg) = 115.71 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange -bot =lib= Lbottom - 2 *r * -2 *t = 2.450 in Cbottom =Cb= 2 *Lc/(Lfb +2 *Lc) = 0.126 Fy- bottom =Fyb= Cb *Fyc + (1- Cb) *Fyf = 57.97 ksi Fya= ( Fya-top)*(Fyb/Fya- bottom) = 29.86 ksi if F= 0.95 Then F*Mn= F*Fya *Sx= Project #: K -011210 -1 Eq. B2.1 -4 4.125 in Eq. B2.1 -1 Eq B2.3 -2 (EQ A7.2 -3) 2.75 in 1.75 In Beam= JiMH 41140/4.125" Face x 0.075" thk Ix= Sx= Ycg= t= Bend Radius =r= Fy =Fyv= Fu =Fuv= E_ top flange =b= bottom flange= Web depth= 2.196 in ^4 1.021 in ^3 2.723 in 0.075 in 0.075 in 55.00 ksi 65.00 ksi 29500 ksi 1.750 in 2.750 in 4.125 in Fy yl= Ycg-t r= 2.573 in y2= depth -Ycg= 1.403 in y3= y2-t r= 1.253 in 4.1 St tural once is Mngineerin 9 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: A.A. BEAM Project: HIGH FIVE SPORTWEAR RMI Section 51, P i 11 Section Bending Configuration: TYPE 1 SELECTIVE RACK Project #: K -011210 -1 Beam= HMH 41140/4.125 Face x 0.075 thk Ix =Ib= 2.196 inA4 Sx= 1.021 in ^3 t= 0.075 in E= 29500 ksi Fy =Fyv= 55 ksi F= 150.0 Fu =Fuv= 65 ksi L= 108 in Fya= 59.6 ksi Mcenter =F*Mn= W*L*W*Rm/8 W =LRFD Load Factor= 1.2 *DL + 1.4 *PL +1.4 *(0.125) *PL FOR DL =2% of PL, W= 1.599 Rm= 1 - [(2 *F*L) /(6 *E *Ib + 3 *F*L)] 1- (2 *150 *108 in) /[(6 *29500 ksi *2.196 in ^3) +(3 *150 *108 in)] = 0.926 if F= 0.95 Then F*Mn= F*Fya *Sx= 57.82 in-k Thus, allowable load per beam pair =W= F*Mn *8 *(# of beams) /(L *Rm *W) = 57.82 in-k * 8 * 2/(1081n * 0.926 * 1.599) = 5,786 Ib/pair Mend = W*L *(1 -Rm) /8 = (5786 lb/2) * 108 in * (1 -0.926)/8 = 2,890 in-lb Deflection 4.125 In Dmax= Dss *Rd Rd= 1 - (4 *F*L) /(5 *F*L + 10 *E*Ib) = 1 - (4 *150 *108 in) /[(5 *150 *108 in) +(10 *29500 ksi *2.196 in ^4)] = 0.911 in if Dmax= 1/180 and Dss= 5*W*L ^3/(384 *E *Ib) L/180= 5 *W*LA3 *Rd /(384 *E*Ib *# of beams) solving for W yields, W= 384 *E *I *2/(180 *5 *LA2 *Rd) = 384 *2.196 in^4 *2/[180 *5 *(108 in)A2 *0.911) = 5,2021b /pair Allowable load= 5,202 lb /pair Based on deflection criteria �tru tural e• s ngineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92607 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: hIGh FIVE SPORTWEAR Project #: K -O 112 10- I 3 Pin Beam to Column Connection TYPE 1 SELECTIVE RACK Mconn max= 16,314 in-Ib Load at level 1 Shear Capacity of Pin P1 1- 2- P2 0 P3 1/2 C 12" Connector Type= 3 Pin PIN DIAM= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)A2 * Pi /4 = 0.1507 inA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507inA2 = 3,315 Ib Bearing Capacity of Pin Per the199b AIS! Cold Formed Steel Manual, Sec t3.3: tcol= 0.09 in Fu= 65,000 psi Omega= 2.22 alpha= 2.22 Pbearing= alpha * Fu * diam * tcol /Omega = 2.22 * 65000 PSI * 0.438 IN * 0.09 IN/2.22 = 2,562 lb < 3315 lb Moment Capacity of Bracket Edge Distance =E= 1.00 in Pin Spacing= 2.0 in Fy= 55,000 psi C= P1 +P2+P3 tdip= 0.18 in = P1 +P1 *(2.574.51+P1 *(0.574.5") = 1.667 * P1 Mcap= Sdip * Fbending = 0.127 INA3 * 0.66 * Fy = 4,610 in-Ib Pclip= Mcap /(1.667 * d) = 4610.1 in-lb/(1.667 * 0.5 in) = 5,531 Ib Sclip= 0.127 inA3 SINCE C *d= Mcap = 1.667 AND d= E/2 = 0.50 in Thus, P1= 2,562 Ib Mconn - allow= [ P1* 4. 5"+ P1*( 2. 574.5 ") *2.5 " +P1 *(0.5 74.570.5 "] *1.33 = 2562 LB *(4.5" +(2.574.5 ") *2.5 "+ (0.5 74.5 ") *0.571.33 = 20,306 in -Ib > Mconn max, OK TYPE 1 SELECTIVE RACK -h1Gh FIVE SPORTSWEAR Page q of > 1/12/2010 Structural Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Project #: K -011210 -1 Transverse Brace Configuration: TYPE 1 SELECTIVE RACK Section Properties Diagonal Member = Hannibal 1 -1 /2x1- 1/2x16ga Area= 0.273 inA2 r min= 0.496 in Fy= 55,000 psi K= 1.0 Qc= 1.92 Frame Dimensions Horizontal Member= Hannibal 1 -1 /2x1- 1/2x16ga Area= 0.273 inA2 r min= 0.496 in Fy= 55,000 psi 1.500 in K= 1.0 0.25 in 1.500 in 1c 0.25 in T 1.500 in 1 Bottom Panel Height =H= 42.0 in Frame Depth =D= 44.0 in Column Width= B ='3.0 in Diagonal Member Clear Depth= D-B *2= 38.0 in X Brace= NO V= Vtransv= 1,013 Ib Ldiag= [(D- B *2) ^2 + (H- 6 °) ^2] ^1/2 = 52.3 in Pmax= V*(Ldiag/D) = 1,2041b Pn= AREA *Fn = 0.273 inA2 * 26208 psi = 7,155 Ib Pallow= Pn /52 = 7155 Ib /1.92 = 3,726 Ib fa /Fa= Horizontal brace 0.32 <= 1.33 OK (Id /r)= (k * Ldiag)/r min = (1x 52.3 in /0.496 in ) = 105.4 in Fe= pi ^2 *E/(kI /r) ^2 = 26,208 psi SINCE Fe<Fy /2, Fn= Fe = 26,208 psi Check End Weld Lweld= 2.0 in Fu= 65 ksi tmin= 0.060 in Weld Capacity= 0.75 * tmin * L * Fu * 1.33/2.5 = 3,1201b OK Pmax =V= 1,013 Ib (kl /r)= (k * Lhoriz) /r min = (1 x 44 in) /0.496 in = 88.7 in SINCE Fe>Fy /2, Fn= Fy *(1-fy /4fe) = 34,564 psi fa /Fa= 0.21 <= 1.33 OK Fe= pi^2 *E/(kl /r) ^2 = 37,006 psi Pn= AREA *Fn = 0.273inA2*34564 psi = 9,436 Ib Fy /2= 27,500 psi Pallow= Pn /S2c = 9436 Ib /1.92 = 4,915 Ib TYPE 1 SELECTIVE RACK -HIGH FIVE SPORTSWEAR Page r o of 3, 1/12/2010 S t tural Iconcepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 Anchors By: BOB Project: HIGH FIVE SPORTWEAR Project #: K -011210 -1 Configuration: TYPE 1 SELECTIVE RACK Loads Vtrans =V= 1,013 Ib DL/Frame= 300 Ib Pt/Frame= 9,000 Ib Wst= (0.9 *DL +PL)total= 9,270 Ib LL @ TOP= 3,0001b DL/LvI= 100 Ib DL *0.90 = 90 Ib Lateral Ovt Forces= E(A *hi)= 180,781 in-Ib Total Dead Load per Bay =DL= 300 Ib Fully Loaded rack Frame Depth =D= 44.0 in Htop -M =H= 230.0 in # Levels= 3 # Anchors /Base= 2 T • V -D� SIDF Fl FVATION Vtrans= 1,013 Ib Movt= l(Fi *hi) *1.15 = 1807811n -Ib * 1.15 = 207,898 in-Ib Top Level Loaded Only Mst= Wst * D/2 = 9270 Ib * 44 in /2 = 203,940 in-Ib T= (Movt- Mst) /D = (2078981n -Ib - 203940 in- Ib)/44 in = 90 Ib Critical Level= 3 V1 =Vtop= Cs * Ip * Ws >= 350 Ib = 0.16 * (30001b) = 480 Ib V2=VDL= Cs *Ip *DL =481b Mst= (PL @ top + 0.9 *DL- total) *D /2 = (3000 Ib + 300 Ib *0.9) * 44 in/2 = 71,940 in-Ib Anchor Hgt @ Lvl 3= 230.0 in HtoDratio= 5.2 Movt= V1 *Htop*1.15 + V2 * H/2 = 4801b *230 in *1.15 +481b *230 in /2 = 132,480 in-Ib T= (Movt- Mst) /D = (132480 in -Ib - 71940 in- Ib) /44 in = 1,376 Ib Check (2) 0.5" x 3.25" Embed HILTI KWIKSOLT TZ anchor(s) per base plate. Special inspection is provided per ICC ESR 1917. Fully Loaded: Top Level Loaded: Pullout Capacity=Trap= 2,178 Ib Shear Capacity=Vcap= 2,839 Ib Tcap *Phi= 2,178 Ib Vcap *Phi= 2,839 Ib LA. City Jurisdiction? NO Phi= 1 (45 Ib/2178 Ib) ^1 + (253 Ib/2839 Ib) ^1 = (688 Ib/2178 Ib) ^1 + (120 Ib/2839 Ib) ^1 = 0.11 <= 1.0 OK 0.36 <= 1.0 OK TYPE I SELECTIVE RACK-MG-1 FIVE SPORTSWEAR Page `t of k. 3 1/12/2010 Sjructurai Concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Base Plate Configuration: TYPE 1 SELECTIVE RACK Project #: K -011210 -1 Section Baseplate= 7x5x3/8 Eff Width =W = 7.00 in Eff Depth =D = 5.00 in Column Width =b = 3.00 in Column Depth =d= 3.00 in L = 2.00 in Plate Thickness =t = 0.375 in Down Aisle Loads a = 2.50 in Anchor c.c. =2 *a =d = 5.00 in N =# Andes /Base= 2 Fy = 36,000 psi P = 4,650 Ib Mbase =Mb = 5,000 in -Ib Axial Bearing stress =fa = P/A = P /(D*W) M1= wL ^2/2= fa *L ^2/2 = 133 psi = 266 in -Ib Moment Stress =fb = M/S = 6 *Mb /[(D*B ^2) Moment Stress=fb2 = 2 * fb * LAN = 122.4 psi = 70.0 psi Moment Stress =fbl = fb-fb2 = 52.5 psi M2= fb1 *L ^2)/2 = 105 in-Ib M3 = (1 /2) *fb2 *L *(2/3) *L = (1 /3) *fb2 *L ^2 Mtotal = M1 +M2 +M3 = 93 in-Ib S -plate = (1)(t ^2)/6 = 0.023 in ^3 /in = 464 in -Ib /in Fb = 0.75 *Fy *1.33 = 35,910 psi fb /Fb = Mtotal /[(S- plate)(Fb)] 0.55 OK Tanchor = (Mb- (P *0.9)(a)) /[(d) *N /2] Tallow= 2,178 Ib OK = -1,093 Ib No Tension Cross Aisle Loads Pstatic= 4,650 Ib Movt= 207,898 in-Ib Frame Depth = 44.0 in = 4,725 Ib Pseismic= Movt/Frame Depth P= Pstatic +Pseismic= 9,375 Ib b = Column Depth= 3.00 in L =Base Plate Depth-Col Depth= 2.00 in fa = P/A = P /(D*W) M= wL ^2/2= fa*LA2/2 = 268 psi = 536 in -Ib /in Sbase /in = (1)(t ^2)/6 Fbase = 0.75 *Fy *1.33 = 0.023 in ^3 /in = 36,000 psi fb /Fb = M/[(S-plate)(Fb)] 0.63 OK TYPE I SELECTIVE RACK- 111G11 FIVE SPORTSWEAR Page 1 2_ of 1 3 1/f2/2010 Structural Concepts Engineering 1200 N. Jefferson Ste. Stef Anaheim-CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: HIGH FIVE SPORTWEAR Slab on Grade Configuration: TYPE 1 SELECTIVE RACK Project #: K -011210 -1 IIullEilliiilliilll IIIiiIII'IIIidlli1ill'ill1 llliiiliillliillliilliillliilliilliilli 'illiill y 1 SLAB ELEVATION Base Plate B= 7.00 in D= 5.00 in Load Case 1: Product + Seismic Product DL =DL= 150 lb PL= Product Load= 4,500 Ib Puncture DL DL LL width =a= 3.00 in depth =b= 3.00 in I RMI Section 2.2, eqcn S Pu= 1.2 *DL + 0.85 *PL + 1.4 *Pe = 10,620 Ib Apunct= [(c +t) +(e +t)] *2 *t = 288.0 inA2 Slab Bending Baseofate Plan View eff. Plate width=c= 7.00 in eff. Plate depth =e= 5.00 in Concrete f c= 2,500 psi tslab=t= 6.0 in phi =0= 0.65 P- seismic =Pe= (Movt/Frame depth) = 4,725 Ib Pse= DL +PL +Pe= 9,375 Ib I D Transverse Elev Soil fsoil= 1,000 psf Movt= 207,898 in-Ib Frame depth = 44.0 in (Strength Design Loads) Asoil= (Pse *144) /(fsoil) = 1,350 inA2 x= (L -y) /2 = 9.4 in Fb= 5 *(phi) *(fc)A0.5 /1.4 = 116.07 psi L= (Asoil)A0.5 = 36.74 in M= w*xA2/2 = (fsoil *xA2)/(144 *2) = 307.7 in-Ib Fpunct= 2.66 *phi*sgrt(fc) = 86.5 psi fv /W= Pu /(Apunct *Fpunct) = 0.427 <= 1.0 OK Load Case 2: Static Loads y= (c *e)A0.5 + t *2 = 17.9 in S -slab= 1*tA2/6 = 6.0 inA3 fb /Fb= MKS- slab *Fb) = 0.442 <= 1.33, OK Puncture DL= 150 Ib PL= 4,500 Ib DL +LL=Ps= 4,650 Ib Pu= 1.2 *DL + 1.4 *PL = 6,480 Ib Apunct= [(c +t) +(e +t)] *2*t = 288 inA2 RMI Section . ? eqtn 2 Slab Bending soil area based on unfactored loads Asoil= (Ps *144) /( fsoil) = 670 ftA2 x= (L -y) /2 = 4.0 in Fb= 5 *(phi) *(fc)A0.5 /1.4 = 116.07 psi L= M= (Asoll)A0.5 25.88 in w*xA2/2 (fsoil *x^2)/(144 *2) 55.0 in-Ib Fpunct= 2.66 *phi *sgrt(Pc) = 86.5 psi fv /Fv= Pu/(Apunct *Fpunct) = 0.260 < =1.0 OK y= (c *e)A0.5 + t*2 = 17.9 in S -slab= 1 *tA2 /6 = 6.0 inA3 fb /Fb= M /(S- slab *Fb) = 0.079 <= 1.0, OK TYPE I SELECTIVE RACK -HIGH FIVE SPORTSWEAR Page l of tj 1/12/2010 • City of Tu ila Jim Haggerton, Mayor Department of Community Development January 28, 2010 David Little 9883 40 Ave S Seattle, WA 98118 RE: Correction Letter #1 Development Permit Application Number D10 -009 High Five Sportsware —18200 Segale Park Dr B Jack Pace, Director Dear Mr. Little, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached memo. Fire Department: Alan Metzler at 206 575 -4407 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fifer Marshall it Technician encl File No. D10 -009 W:\Permit Center\Correction Letters V010\1310-009 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: January 20, 2010 Project Name: High Five Sportswear Permit #: D10 -009 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide dimensions on the plan to identify the length of egress travel leading to the exit discharge doorways from the rack aisle ways. Show width of the aisle ways. (IBC 1014.3) 2. Identify path of egress illumination for the aisle ways. Provide documentation or details on the plan to show paths of egress shall show sufficient illumination of 1 foot - candle at the walking surface leading to the exit discharge doorways. (IBC Section 1006) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Tukwila Fire Prevention Bureau Al Metzler, Firc Project Coordinator Fire Prevention Bureau Review Memo Date: January 27, 2010 Project Name: High Five Sportswear Address: 18200 Segale Park Dr B Permit #: D10 -009 Plan Reviewer: Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. The scale on rack layout sheet no. 1 does not match the dimensions shown on elevation drawing sheet no. SCE 1. 2. Provide details on commodities to be stored in the racks. 3. Provide details on rack shelving. 4. Provide ceiling height and maximum storage height of product. 5. Provide existing fire sprinkler density of the proposed rack storage area. Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206- 575 -4407. No further comments at this time. PE 1G C Y • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -009 DATE: 02 -05 -10 PROJECT NAME: HIGH FIVE SPORTSWARE SITE ADDRESS: 18200 SEGALE PARK DR B Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bu li ding Division Public Works AtAgl Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02- 09-10 Complete K Incomplete ❑ Comments: Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Dr Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 03 -09-10 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVfiSIION SUBT!IITTAL: • Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Z 5 ( 20( u Plan Check/Permit Number: D 10-009 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: High Five Sportsware 18200 Segale Park Dr B Contact Person: Phone Number: Summary of Revision: pu u,1,P ). e Pr Ct �c , /S c• io (--' u .vi / Li CITY OF TUKW11A FEB 05 2010 c)ERMIT OENTER Sheet Number(s): 2 "Cloud" or highlight all areas of revision including d! s revis Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ;--S—( 0 n \applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: OPERNIi C40RD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -009 DATE: 01 -15 -10 PROJECT NAME: HIGH FIVE SPORTWEAR SITE ADDRESS: 18200 SEGALE PARK DR B X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued EPAR MENt TS• Q� ui ding vision � ; " Ir rev ntlon Public Works Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 01-19-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route IX Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02-16-10 Not Approved (attach comments) DATE: Permit Center Use Only �j CORRECTION LETTER MAILED: 0 V Departments issued corrections: Ping ❑ PW ❑ Staff Initials: J� Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page 1 Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Engineered Products, A Pape Co UBI No. 602684203 Phone 2063943300 Status Active Address 9883 40Th Ave So License No. ENGINPC931CO Suite /Apt. License Type Construction Contractor City Seattle Effective Date 2/20/2007 State Wa Expiration Date 2/20/2011 Zip 98118 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company her Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ENGINSP142RA Engineered Storage Products Co Construction Contractor General Unused 12/1/1986 1/1/2000 Archived GADCOMH991K4 Gadco Material Handling Llc Construction Contractor General Unused 5/24/2001 1/3/2009 Expired ENGINPI013JK Engineered Products Inc Construction Contractor General Unused 4/12/1999 1/6/2010 Out Of Business Business Owner Information Name Role Effective Date Expiration Date Ct Corp Systems Agent 02/20/2007 Bond Amount Salman, David E President 02/16/2007 08748464 Riecke, Robert J Secretary 02/16/2007 Saylor, Thomas H Treasurer 02/16/2007 Hollingshead, Danny W Vice President 02/16/2008 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 FIDELITY & DEPOSIT CO OF MD 08748464 02/13/2007 Until Cancelled $12,000.00 02/16/2007 Assignment of Savings Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 02/18/2010 REVISIONS No changes shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ echanical lSElectrlcat ❑ Plumbing ❑ Gas Piping City of Tukwila B . ii_DING DIVISION FILE COPY Permit No. Plan review approval is subject to a and omi Approval of construction • • does not authorize the violation of any a code or ordi : Receipt of approved • d Mons is acknowledged: 1 City of Tukwila BUILDING OIVIRION By Date: City Of Ttikwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE YE FEB 16 2010 ri °eu+ JAN 15 2010 ITC 00 9 Exit Exit 84 Rays Exit 5,_6 „t Ypt // 111 Thd IIl IIIIIIIIIIII 0 0 0 0 0 0 A.. III C 10 I� . 20' 991_6" Exit W111111 0 0 Exit bio oO'1 REVIEWED FOR CODE COMPLIANCE APPROVE FEB 16 2010 City of Tukwila BUILDING DIVISION C45ii cu°HU► JAN "15'[010 PERMIT CENTER DL NTS 01/15/10 1 JS 1 Exit Ext 36' -5 PATH OF EGRESS PATH OF EGRESS PATH OF EGRESS TO BE ILUMINATED PER CODE TO 1 -FOOT CANDLE AT THE WALKING SU - . ' LEADING E'IT DIS A DOORWAYS. err+ ens% ) ctL; ;`►j u/91 req r 1663. S RED COMMODITIES: SS 3 : 4. NO : • APSULATED. PRIMARILY COTTON CLOTHING PRODUCT WIRE DECK SHELVING - Z'X4" GRID 28' CLEAR HEIGHT IN BUILDING WITH TOP OF PRODUCT AT 24' -10" SPRINKLER DENSITY - .3 5600 SQUARE FT. Storage and Material Handling Specialists 9883 40TH AVENUE SOUTH 7///77 0 yrrii PLA\ VI =W SCALE: 3/32" = 1' -0" Exit REVIEWED FOR CODE COMPLIANCE AMR Via FEB 16 2010 City of Tukwila BUILDING DRIISION CORRECTION ‚000c1 RECEIVED FEB 05 2010 PERMIT CENTER tft 206 - 575 -6688 0 LL 206 -394 -3300 D w � re I- w W D Z o • rt za w a) ■ LINEN Q 11-d CC CK °- a � a o c .... c) DRAWN BY: D. LITTLE SCALE: STATED DATE: 02/04/10 JOB NO: 052605 -0011 CHECKED BY DL SHEET NO. 1 OF 1 SHEET; Exit 84 ays 5 ypI // Exit rell4r 7Mir P rr / .ret bto oO"l REVIEWED FOR CODE COMPLIANCE APPROVED FEB 16 2010 City of Tukwila BUILDING DIVISION The P.E. certification provided herein by SCE, Inc. pertains to the storage rack components only. rill other components are outside the scope of this certification. JAN 12 19 c2�ANSRA JAN 15'2010 PERMIT CENTER REVISION DESCRIPTION DATE •� N M 'o* LO co THIS DRAWING AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSES, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT EXPRESS WRITTEN CONSENT OF ENGINEERED PRODUCTS. ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. Ave S Seattle, WA 98118 —394-3300 Fax: 206 - 575 -6688 a and Iklaterial Hand ling Specialists Z 0 g O "t N Z1 v 00 o Wrniicl) n.... III APPROVED DATE 1 DRAWINGS PREPARED FOR High Five Sportswear 18200 Segale Park Drive B Tukwila, WA 98188 DRAWN BY: DL SCALE: 1/16 " =1' -0' DATE: 09 9 JOB NO: 1 CHECKED BY JS SHEET NO. 1 OF SHEETS 3" COLUMN 5" 711 NOTES: USE @ ALL COLUMN /BASE LOCATIONS TYPICAL. -I" " 3 3/8" 12" MIN. 1 1/2" 11/16" 3/8 "0 X 7/8" SLOT 4 PLCS 3/4" DESCRIPTION BASE PLATE: 7" X 5" MATERIAL STEEL YIELD ASTM A36, Fy= 36,000 PSI 3/8" THICK PLATE DESCRIPTION MATERIAL STEEL YIELD COLUMN: IF 3013 13 GAGE ASTM A570, Fy= 55,000 PSI DESCRIPTION MATERIAL STEEL YIELD BRACING: HORIZ. & DIAG. 16 GAGE STEEL ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL BRACE LOCATIONS TYP. DESCRIPTION ROW SPACER MATERIAL 14 GAGE STEEL YIELD ASTM A36, Fy = 36,000 PSI NOTES: ATTACH WITH (4) 3/8 "0 GR.5 BOLTS, (2) @ EACH END FOR DOUBLE ROW UNITS. 1 11/16" I J 5/160 SAFETY PIN 6" 1" 2" 2" <TYP. n u 0 33/16" 7/160 GR. 55 RIVET TYP. >1 /8' BASE PLATE F.F. 3 1/4" MIN. EMBED. O 1/2" PERIODIC SPECIAL INSPECTION REQUIRED DURING INSTALLATION DESCRIPTION MATERIAL STEEL YIELD 3 -PIN CONNECTOR 7 GAGE ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL BEAM TO COLUMN CONNECTION LOCATIONS TYP. DESCRIPTION 4-1/8" BEAM ( #41140) MATERIAL 14 GAGE STEEL YIELD ASTM A570, Fy= 55,000 PSI NOTES: USE @ ALL BEAM LOCATIONS TYP. DESCRIPTION HILTI KWIK BOLT TZ ANCHOR SIZE 1/2"0 X 3 1/4" MIN. EMBED. ESR# 1917 NOTES: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. 80" 240" 80" TYPE 1 SELECTIVE RACK 108" 70" FRONT VIEW 2" \ ESCRIPTION 4 DEEP PUSHBACK UNIT ELEVATION GENERAL PROJECT NOTES 1. DESIGNED PER THE REQUIREMENTS OF THE 2006 IBC 2. SEISMIC CRITERIA Ss = 1.429, S1 = 0.489, Fa = 1.0, Fv = 1.511 Ip = 1.0 (NO PUBLIC ACCESS) Sds = 0.953, Sd1 = 0.492, OCC CATAG. II SITE CLASS D, SEISMIC DESIGN CATAG. D. 3. STORAGE CAPACITY: 3000# PER LEVEL TYP. 4. ANCHORS HILTI KWIK BOLT TZ WEDGE ANCHOR ESR #1917,1/2 "0 x 3 -1/4" MIN. EMBEDT. OR POWER STUD +SD2 ESR #2502, 1/2"0 x 3 -3/4" MIN. EMBEDMENT. (2) ANCHOR PER BASE PLATE @ OPP. CORNER. 5. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 6" x 2500 PSI 7. SOIL BEARING PRESSURE 1000 PSF @ GRADE OR BETTER 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER. INSTALL TO SNUG TIGHT FIT WITH ALL PLYS IN FLAT CONTACT 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BYAWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BEI IER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. Dt0-4;00ci REVIEWED FOR CODE COMPLIANCE RPM En FEB 16 2010 City of Tukwila BUILDING MGM CITYDFIUKVNLA JAN '15'2010 PERMIT CENTER 1 EXPIRES 10/25/ 11 JAN 1 2 2010 SCE 1 OF 1