HomeMy WebLinkAboutPermit D10-049 - MOY RESIDENCE - DECK COVERMOY RESIDENCE
14906 MACADAM RD S
D10-049
Citylk Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http://www.c i. to kwil a. wa. us
Parcel No.: 7661600207
Address: 14906 MACADAM RD S TUKW
Suite No:
DEVELOPMENT PERMIT
Permit Number: D10 -049
Issue Date: 03/04/2010
Permit Expires On: 08/31/2010
Tenant:
Name: MOY RESIDENCE
Address: 14906 MACADAM RD S , TUKWILA WA
Owner:
Name: MOY BOBBY +SAVOEUN P CHHOEUN
Address: 14906 MACADAM RD S , TUKWILA WA 98168
Phone:
Contact Person:
Name: BOBBY MOY
Address: 14906 MADACAM RD S , TUKWILA WA 98168
Phone: 206 795 -9486
Contractor:
Name: OWNER AFFIDAVIT - SAVOEN CHHOEUN
Address: 14906 MACADAM RD S , TUKWILA WA 98168
Phone: 206 -795 -9486
Contractor License No:
Expiration Date:
DESCRIPTION OF WORK:
CONSTRUCTION OF 280 SF DECK COVER (DECK PREVIOUSLY EXISTING)
Value of Construction: $1,200.00 Fees Collected: $156.96
Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2006
Type of Construction: VB Occupancy per IBC: 0022
* *continued on next page **
doc: IBC -10/06
010 -049 Printed: 03 -04 -2010
City *Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /wwwci.tukwila.wa.us
Permit Number: D10-049
Issue Date: 03/04/2010
Permit Expires On: 08/31/2010
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter:
Permit Center Authorized Signature:
N
Ata Date: 0
IV
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting f this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction the performance of work. I am authorized to sign and obtain this development permit.
Signature:
Date: 05/6 /lo0/6
1
Print Name:
3QX)LUn
cHHOeon
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC -10/06
D10 -049 Printed: 03 -04 -2010
Parcel No.: 7661600207
Address:
Suite No:
Tenant:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
14906 MACADAM RD S TUKW
MOY RESIDENCE
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
D10-049
ISSUED
02/22/2010
03/04/2010
1: ** *BUILDING DEPARTMENT CONDPI'IONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any
requirements for special inspection.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
D10 -049 Printed: 03 -04 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: W g/..Q ") Cittl
E
Print Name: sOV V a l' Ch hoeun
Date:
ordinances governing
or local laws regulating
doc: Cond -10/06 D10 -049
Printed: 03 -04 -2010
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No.
Mechanical Perinit.No.
Plumbing /Gas Permit No.'
Public Works Permit No:.
Project No.
(For 'office use only) •
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: liite He o
Site Address: \:-1 -c1 110__(0 11 a CICI Wn VD S Suite Number: Floor:
Tenant Name:)Obb N ( J New Tenant: ❑ Yes El „No
Property Owners Name: -3.b M 0
Mailing Address:
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name:
Mod
Day Telephone( o () 7 G35 £y 8 (
Mailing Address:
Zip
E -Mail Address:
City
State
Fax Number:
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: W fe r
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
Zip
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
HA\Applications\rorms- Applications On Line\2009 Applications \I -2009 - Permit Application.dnc
Revised- 1 -2009
bh
State
Zip
Page 1 of 6
•
BUILDING PERMIT INFORMATION - 206- 431 -3670
Valuation of Project (contractor's bid price): $1200
Existing Building Valuation: $
Scope of Work (please provide detailed information):
a `d CO S F Roof ccxi o'
DecK E)63 1r-
Will there be new rack storage? ❑ Yes
D.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If `yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS: `,
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Other (specify) da,V, t,
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ' J No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpphcations \Forms - Applications On Line\2009 Applications \I -2009 - Permit Apphcatfon.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1St Floor
rd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
o �/ /$ 0
A U
1/
,O
�J
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If `yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS: `,
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Other (specify) da,V, t,
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ' J No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpphcations \Forms - Applications On Line\2009 Applications \I -2009 - Permit Apphcatfon.doc
Revised: 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING -OWNER OR AUTHORIZE AGENT:
Signature: cl) Ov-Q ,0/`"- C
Print Name: 6ct\.) LJ C J € U>r1
Mailing Address: 11--1C10(0 MG Eci(n11') S
- - Date: -ID
Day Telephone: ( l () b) S5 - LI 13 -A
TU4((Ailq WA 88165
City State Zip
Date Application Accepted:
021
1
\10
Date Application Expires:
01
I n / vo
Staff Initials:
li�
H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
•
City of Tukwila
1005301 -1 0003 02/22/2010 '010 001 101
DOD Fern Plus - General Fund $152.46
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 7661600207
Address: 14906 MACADAM RD S TUKW
Suite No:
Applicant: MOY RESIDENCE
RECEIPT
Permit Number: D10-049
Status: PENDING
Applied Date: 02/22/2010
Issue Date:
Receipt No.: R10 -00295
Initials: JEM
User ID: 1165
Payment Amount: $156.96
Payment Date: 02/22/2010 08:50 AM
Balance: $0.00
Payee: SAVOEUN CHHOEUN
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash
Authorization No.
ACCOUNT ITEM LIST:
Description
156.96
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
•
000.322.100
000.345.830
640.237.114
Total: $156.96
92.40
60.06
4.50
PAYMENT
RFCEVED
doc: Receiot -06 Printed: 02 -22 -2010
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION RECORD
Retain a copy with permit
Di o o17
PERMIT
ProjeGt:n
MO Re- le\ [�
Type of Ins ection: I 1
1-4 A-4. i . t -°' '`>/i�
Address:
Date Call
Special Instructions:
/
Date Wanted '�a.
2_ u , 3
-- r p.m.
Requester:
Phone No
/,o( -ASS --di 03Z_
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Ins
Date:
• El $60.00 REINSPECTION FEE REQUIRkD. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Catt.to.schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
D10 -o41
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IZ
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project
Type of nspecti • n
Addre "s9 6
M�
�k�'i
Date Called:
,I ,r -.
Special Instructions:
1 `PhoJOC"
Date Wanted:, ,a.m`�
.,Qr -- -i0 P.m.
Requester:
riSS -4Q32,--
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
i) )16 /- Pz.0.01
A.• 1 610.01frfr, oS /-&4,7 )1-el A-
a
J4 -4
q
iM
Inspector:
t►Q
LI $60.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
Receipt No.:
Date:
INSPECTIO NO.
INSPECTION RECORD
Retain a copy with permit
Oio ,��Q
W�
PERMIT N0.
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: ,
i�C} J eS • d�lzn
Type of Inspection:
R 6 u Sip wa /{
Address:
Ili. i. 04 MA 4 A-Ai
Date Called:
Special Instructions:
Date Wanted: / -�`a„
3_ #' /d P.m.
Requester:
Phone °� 6/ — f c-S —4/03 2-
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Date_���
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: 'Date:
• PEaMrPCOORDCOPVa
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D10 -049 DATE: 02/22/10
PROJECT NAME: MOY RESIDENCE
SITE ADDRESS: 14906 MACADAM RD S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
dirf'Division
Pu is Works LLJJ
AtA ►ilk 02-
e Prevention
Structural
AIM MOh— O2-i J
Planning Division
nPermit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete r$
Comments:
Incomplete
DUE DATE: 02/23/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Building
Please Route, Structural Review Required n No further Review Required n
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03/23/10
Approved Approved with Conditions gl Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing sl ip.doc
2 -28 -02
•
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670 FAX (206) 431 -3665
E -mail: tukplanOci.tukwila.wa.us
Permit Center /Building Division
206 431 -3670
Public Works Department
206 433-0179
Planning Division
206 431 -3670
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
PERMIT NO: D I 0 l 9
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
U► `j Ue un C v l Y 1�'w Yi , states as follows:
[please print name]
1. I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number 12., and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
Owner /Owner's Agent*
Signed and sworn to before me this
day of , 20 (0 .
NOTARY PUBLIC in and for the State of Washington
Residing at C
Name as commissioned: s'I�tSG� r� ��C�!
My commission expires: IV —) l^ c;-e) � I
, County
18.27.090 Exemptions. The regisu tion provisions of this chapter do not apply tip
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
io. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
ii. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity who holds, a' valid:electrical contractor's
license under chapter. 19 28,RCW.tha't'employs a certified
journeyman electrician; a.cartified regidential specialty
electrician, or an electrical trainee meeting the
requirements of chapter 19.28 RCW to perform plumbing
work that is incidentally, directly, and immediately
appropriate to the like -in -kind replacement of a household
appliance or other sm_ a'il jiqusehold utilization equipment
that requires limited electric power and limited waste
and /or water connections. An electrical trainee must be
supervised by a certified electrician while performing
plumbing work.
• Per Washington State Department of Labor and Industries, lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.
2143 llWa3d
z
a, z
a
c=.
0
A
v';
coo zx'fri
CD g3'
p, _ coo tv
oc • a-ocD
o CD (0 0
'a Q a
ts'm <'ocD
�•ai < ?
CD W CD
CD
5• �8
N CD
w
33
2
0
co
•
PROJECT DATA
PROJECT:
BOBBY MOY RESIDENCE
OWNER: PROJECT ADDRESS:
MR. BOBBY MOY
1490G MACADAM RD. 5.
TUKWILA, WA 98188
LEGAL DESCRIPTION:
MR. BOBBY MOY
1 4906 MACADAM RD. 5.
TUKWILA, WA 98188
SEATTLE LAND COMPANY'S 5 ACRE TRACTS LOT 2 CITY OF TUKWILA
SHORT PLAT NO L02 -051 RECORDING NO 20050601900007
(BEING A PORTION OF SW QTR NW QTR STR 23- 23 -04)
PARCEL NUMBER:
7661600207
ZONING CLASSIFICATION:
LDR
PROJECT DESCRIPTION:
PERMITTING COVER OVER EXISTING DECK
BUILDING DEVELOPMENT SQUARE FOOTAGE:
RESIDENCE STRUCTURE:
ENTIRE RESIDENCE:
BASEMENT:
MAIN FLOOR:
SECOND FLOOR:
THIRD FLOOR:
TOTAL:
PRIMARY RESIDENCE:
BASEMENT:
MAIN FLOOR:
SECOND FLOOR:
THIRD FLOOR:
TOTAL:
ACCESSORY UNIT:
BASEMENT:
FIRST FLOOR:
SECOND FLOOR:
THIRD FLOOR:
TOTAL:
ABBR.:
0 S.F.
1,300 5.F.
1,190 S.F.
0 S.F.
2,490 S.F.
0 S.F.
I ,300 S.F.
1,190 S.F.
0 S.F.
2,490 S.F.
ALUM.
APP.
BD.
BLDG.
CLG.
CONC.
CONST.
CONT.
ALUMINUM
APPROVED
BOARD
BUILDING
CEILING
CONCRETE
CONSTRUCTION
CONTRACTOR
DEMO.
DET.
DR.
DRS.
ELECT.
ELEV.
EQ.
EX'G.
DEMOLITION
DETAIL
DOOR
DOORS
ELECTRICAL
ELEVATION
EQUAL
EXISTING
CONSTRUCTION SYMBOLS
0 S.F.
0 S.F.
0 S.F.
0 S.F.
0 S.F.
FLR.
GYP.
HDWR.
H.M.
MAT.
MAX.
MECH.
MIN.
X/X -X
SECTION/DETAIL
("--".r."-X/X -X
t ) SECTION/DETAIL
■
Vicinity Map
BUILDING DEVELOPMENT SQ. FOOTAGE (CONT.):
RESIDENCE STRUCTURE:
RESIDENCE DECKS:
BASEMENT:
FIRST FLOOR:
SECOND FLOOR:
THIRD FLOOR:
TOTAL:
GARAGE:
FIRST FLOOR:
TOTAL:
LOT SQUARE FOOTAGE:
8,754 S.F.
0 S.F.
543 S.F.
0 S.F.
0 S.F.
543 S.F.
440 S.F.
STRUCT. FTPRNTS. (INCLUDE EAVES OVER 24 ")
RESIDENCE:
SECOND FLOOR:
THIRD FLOOR:
GARAGE:
TOTAL:
LOT COVERAGE:
8,754 S.F. X 35% =3,064 S.F. MAX. COVERAGE
1,740 S.F. DIVIDED BY 8,754 S.F. = 20% COVE
PARKING SPACES:
2 PARKING SPACES ON PROPERTY.
ALLOWABLE BUILDING SETBACKS:
FRONT YARD: 20' -0"
SIDE YARDS: 5'40"
REAR YARD: 10-0"
FLOOR
GYPSUM
HARDWARE
HOLLOW METAL
MATERIAL
MAXIMUM
MECHANICAL
MINIMUM
MTD.
MTL.
N.I.C.
O.C.
PLUMB.
PLYWD.
P.V.C.
REQ'D.
MOUNTED
METAL
NOT IN CONTRACT
ON CENTER
PLYUMBING
PLYWOOD
POLY VINYL CLORIDE
REQUIRED
DRAWING INDEX
Q'
zo
E
440 S.F.
1,300 S.F.
0 S.F.
0 S.F.
440 5.F.
I ,740 5.F.
0 •
5.
a w 5.
CD 2.8 13
a
co Q. I-
%.0( oaEra
c1
CL R
8
§. 5 a
�D CD= O
a0CLa
cn
0
SIMILAR CR m =. O
STRUCTURAE ' 61 9)
TYPICAL
WOOD
WITH
AT
AND
SIM.
STRUCT.
TYP.
WD.
W/
• COVER SHEET: PROJECT DATA, FRAMING NOTES
• SITE PLAN: ARCHITECTURAL SITE PLAN
• A- I : DECK FLOOR COVER PLANS,
ELEVATION SECTIONS, AND DETAILS
FRAMING NOTES:
I .) ALL STRUCTURAL LUMBER TO BE NO. 2 DOUGLAS FIR
2.) ROOF SHEATHING TO BE NAILED @6" O.C. @EDGE SUPPORTS
AND @ 12" O.C. @INTERIOR SUPPORTS. NAILS TQ E_B_.� 8 &__
0
to ®m
U Om
Crn
C:460i
m
A
1
z
ensti
Er
0
Bobby Moy Residence
14906 Macadam Rd. S., Tukwila, WA 98188
Cover Sheet
1 of 3 Sheets
Revisons:
Date: 2/21/2010
Dh2 Drafting
2420 "K" St. SE
Auburn, WA 98002
4906 Macadam Rd. S.
;rlcal Meter I
3s Meter
Sidewalk
ND6?CPQN
70-0"
20' -0" Front Set Back
ti b1b i �N
Ex'g. Conc. Driveway
Ex'g. Rockery
7'-
Ex'g. Front Porch
T-0" Side Set Back
20-0"
(0-0")
8' -8"
1
1
1
—
1
North -->
2' 0" Typ.
Overhang
Existing Deck <30" above Ground
3G' -0'
28'-0"
0
0
10-0" Back Set Back
(o'-0')
Site Man
Scale: 3/32 " =1' -0"
4
s
0
ti 0
� r
z O A
T. Bobby Moy Residence
it 14906 Macadam Rd. 5., Tukwila, WA 98188
an
Revlsons:
Site Man
2 of 3 Sheets
U
Date: 2/21/2010
Dh2 Drafting
2420 "K" St. SE
Auburn, WA 98002
i\
\
t
r 7
+ l
\
\ \
L (0, -01
\
0
v
Existing Single Family Residence
/
/ /
I
i
I
I
__
1
1
1
—
1
North -->
2' 0" Typ.
Overhang
Existing Deck <30" above Ground
3G' -0'
28'-0"
0
0
10-0" Back Set Back
(o'-0')
Site Man
Scale: 3/32 " =1' -0"
4
s
0
ti 0
� r
z O A
T. Bobby Moy Residence
it 14906 Macadam Rd. 5., Tukwila, WA 98188
an
Revlsons:
Site Man
2 of 3 Sheets
U
Date: 2/21/2010
Dh2 Drafting
2420 "K" St. SE
Auburn, WA 98002
•
Existing Single Family Residence
[Sliding Glass Door
r-
L111L
L -J
New Deck Cover Above
(See Plan Below)
New Post Footings
big. Deck Bench
Ex'g. Deck Step
Note:
Ex'g. Cedar Decking to be removed
as necessary for pouring and setting
of new Footings and Posts
LOJ J11L_
L_J L -J
36' -0"
Existing Single Family Residence
"A"
Ex'g. Deck floor Plan
Scale: 3/ I G "= I' -0"
4x6 P.T. Beam
"B"
u ■■1111■■■■■■ ■■■■1111mmii1%■■
�� � ■ ■■ U•uau
� ■••a
i■■■
■■11■ ■■11 ■■■■■11■
/1111 AN 11■11■■11■11■11■■1111■11■111111
iMM11■11■ ■■11■ ■11■ ■1111 ■1111111111111111■■
'411 ■11■ ■■■■ ■■1111111111■■■11■■11■■■
`41■ ■ ■ ■ ■ ■■ ■ ■■ ■ ■ ■■■ ■ ■ ■ ■■■■
ymmuumummomom 1 ■1111■■ ■■■ ■ ■ ■ ■ ■ ■■■11■■■■ RRRRRRR ■B'IRMRRRRW
I' -0" 4" Gutter
(4) 4x4 P.T. Posts El Spaced
28' -0"
See Detail "A"
C 12"
_12"
New Deck Cover Plan
Scale: 3/1 G"= I' -0"
Standard Tar Shingles over
301b Felt Paper over 1/2" Waferboard
See Detail "Ba"
2x6 @24" o.c.
Ex'g. Deck
2x6 Fascia
4" Gutter
Fence/Property Line
I' -0"
17117v(dt
Qork. mctOper
Lo T Q
A
■■■■■ n11■ 11■■ 11 ■■1■■11t!■11■■■N1\■■■■■ONWW■■E
Opp.
Existing Single Family Residence
Gutter drain
+.. water away from house)
See Detail "C "--•\
10-0" Min.
Elevation Section "A" $ "A" Opp
Mashing
(Behing ex'g. siding)
big. Ext. Wall
~ 4 ",
NIP 0x6" @4" o.c.
g Bolts (hot-clipped Galv.)
(.bit b0l41 �l1 a
Section
Scale: 3/16 " =1' -0"
2x6 Ledger
hurricane Tie
Roof per Elevs.
Joist hanger 2x6 Rafter
49 wAU eitVac, IN StMit
Scale: I /2 "= I' -0"
2x6 Rafters
hurricane Tie
Post Cap
Section
Scale: I/2 " =1' -0"
Roof per Elevs.
Mashing
4" Gutter
24 Fascia
4x6 P.T. Beam
4x6 P.T. Beam
4x4 P.T. Post
1
Section
Scale: I /2 "= I' -0"
Post Base
Conc. Footing
p
L_J
Elevatid !1 Section "BBh —�
S _ I"
' -0
r- ®m WED
cu 1711.<
tC ill CD
OZ
CITY OltUlhLA
FEB 2 2 Z010
PERMIT CENTER
2x6 Rafters
\-4x6 P.T. Beam
4x4 P.T. Post
4x4 P.T. Post
Elevated to prevent
ground contact
Section `I ° "�)
I 2" below
Finish Grade
Scale: I/2 "= I' -0"
Bobby Moy Residence
1 4906 Macadam Rd. S., Tukwila, WA 98188
n 3 of 3 Sheets
A -I
Revisons:
Date: 2/21 /2010
Dh2 Drafting
2420 "K" St. SE