Loading...
HomeMy WebLinkAboutPermit D10-076 - RAINIER UNISERV COUNCIL (WEA) - TENANT IMPROVEMENTRAINIER UNISERV COUNCIL (WEA) 575 ANDOVER PK W D10 -076 City'Of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049144 Address: 575 ANDOVER PK W TUICW Suite No: DEVELOPMENT PERMIT Permit Number: D10-076 Issue Date: 03/31/2010 Permit Expires On: 09/27/2010 Tenant: Name: RAINIER UNISERV COUNCIL (WEA) Address: 575 ANDOVER PK W , TUKWILA WA Owner: Name: SOUTHCENTER CORPORATE SQUAR Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 Phone: Contact Person: Name: TAMARA GENZALE Address: 635 ANDOVER PK W SUITE 107 , TUKWILA WA 98188 Phone: 206 - 575 -3080 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206 - 361 -2989 Contractor License No: DPINCGC066BU Expiration Date: 01/31/2012 DESCRIPTION OF WORK: 2ND FLOOR TENANT IMPROVEMENTTO INCLUDE DEMOLITION OF EXISTING PARTITIONS, DOORS AND OTHER FEATURES Value of Construction: $15,000.00 Fees Collected: $622.10 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -10/06 D10 -076 Printed: 03 -31 -2010 City ai'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D 1 0-0 76 Issue Date: 03/31/2010 Permit Expires On: 09/27/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: 3, t3 t -C O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development ermit. Signature: 1 ` Date: �� 1 �� Print Name: cAnot Vl V1 vin V1. V/11 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -076 Printed: 03 -31 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2623049144 Address: Suite No: Tenant: 575 ANDOVER PK W TUKW RAINIER UNISERV COUNCIL (WEA) Permit Number: Status: Applied Date: Issue Date: D10 -076 ISSUED 03/12/2010 03/31/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition nibble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY.OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D10 -076 Printed: 03 -31 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not doc: Cond -10/06 D10 -076 Printed: 03 -31 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. ( THE OCCUPANT LOAD FACTOR FOR THE LARGE CONFERENCE ROOM IS 15, NOT 100 AS FOR THE OFFICE AREAS. THEREFORE THE TOTAL OCCUPANT LOAD EXCEEDS 49 AND EMERGENCY EGRESS LIGHTING AND EXIT SIGNAGE IS REQUIRED.) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 39: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Cond -10/06 D10 -076 Printed: 03 -31 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** does not imply approval of Fire Prevention Bureau at doc: Cond -10/06 D10 -076 Printed: 03 -31 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: " ' _0 V\ . Date: Print Name: 7 I V,- 11(101-W ordinances governing or local laws regulating doc: Cond -10/06 D10 -076 Printed: 03 -31 -2010 CITY OF TUKWIL1P Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us • Building Permit No. 10 -0 7p Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: p C1 /eV Pelt/Y- we q 1201111. I Y / L p V cculoi W b/61l Tenant Name: King Co Assessor's Tax No.: Property Owners Name: KAe i weir eV Pel (111G ,2,40-7,w4-1 I q'k Suite Number: Floor: New Tenant: Yes ❑..No Mailing Address: ((GI I -?Mo r \ v ,V 1. ,svi f' I v~I 0 SCU €, City State c1c114 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: TOI YVV Y1I G-elnol 10 Day Telephone:: t iV I Mailing Address: U%f (1o/eV PUv(L Wet, 107 � // (M "1 n City E -Mail Address: fi�evyialeC&p(nIC4 Ci1't'1 Fax Number: 30W vvft qt. r g Zip ip w 7c I (c1 c GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 112-21) Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: On WV f t^ Y V �S i(/)a s �^ Mailing Address: 2' 7/ I VAT) 1 r 1 V 1% €i SPott'e 11'v fr 'T %I �_�q n I ,,� City State Zip Contact Person: c-� 1 V `�i 14v 1 V C1 �l) Day Telephone: 7ia0 � I I `-1 E -Mail Address: ' • YOVO VV 0 Q nnn1/00 S iV1 •COW Number: `?/0 b 9'4 I 4 3 b ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applicetions\Pmms- Applicatiau On Line \2009 Applications \1-2009 - Permit Application doe Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFOION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ fS S 0 DO Existing Building Valuation: $ Scope of Work (please provide detailed information): 2incl floc) V lei\ Vt IV pv- ovtel' IeV 1 k- tO 'maxie 6e6vo1 iov' of- exi4incj ns,c1oovc (V O -Ivey -ffiivves. Will there be new rack storage? ❑ Yes Qj. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: El Sprinklers Er- Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes gi No If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H.\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor t'''7 -�l 1 V "J \CP, 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: El Sprinklers Er- Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes gi No If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H.\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. AGENT: _ Date: , l 17/ 1 U Print Name: 1 r xIVo /17.1/ 74le�/ }, Day Telephone: 2.00- r��aS' �f �g0 Mailing Address: b9--}g �"IweV I�1►' �f-` SI cvi , of 1 "5-� V `,� V V A � g-1 D5 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H: Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application. don Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049144 Permit Number: D10-076 Address: 575 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 03/12/2010 Applicant: RAINIER UNISERV COUNCIL (WEA) Issue Date: Receipt No.: R10 -00453 Payment Amount: $622.10 Initials: WER Payment Date: 03/12/2010 03:58 PM User ID: 1655 Balance: $0.00 Payee: SOUTHCENTER CORP SQUARE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2886 622.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $622.10 374.30 243.30 4.50 doc: Receipt -06 Printed: 03 -12 -2010 #9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit C� orO-o')( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P� r Cf. V �! TYPe of trtispectio. i b Address_ ;_ �A Ve - 141; KKK Date Called: Special Instructions: WJ 6 ` 2 q� 2 4 —� ��� _ ti ! r Date Wanted: ` . G l J a.m,2 p.m. Requester: Phone 7No: (0 /,, SCo Approved per applicable codes. Corrections required prior to approval. COMMENTS: P Inspe Sct r:�1' Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: 1 .. M!'1 _ _ _ _ ,F 4 Mf�i— _...._L- ...,cYv eteh4L.tsL4i• —rMi INSPECTION RECORD Retain a copy with permit INSP CTION NO. .PEERMIT NO: CITY OF TUKWILA BUILDING DIVISION _p4( 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: LAI Type of Inspectio �� 7 Address: 5 11 vugojei J Date Called: Special Instructions: D4�. ^'4 — d ( Date Wanted I/ D � to am. --irrn. Requester: Phone No: 2,®6 -'773 --9156 Approved per applicable codes. 10 Corrections required prior to approval. COMMENTS: f .Lll ii(A/ f'. N•9/ -- A/Fee/017 VVIYe0, ddelb,047, 120./Ale° — .cam,cs ,it/4- IA Date 0.00 REINSPECTION iEE R[1IRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. ' INSPECTION RECORD Retain a copy with permit ■iO -6:96 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro' ct: "A 1n . *// 2/� /h:Sa y Type of Inspection: • L47/ Ai- - F " I Address: 6-7 4,1-( 92-4°/?/‘ C.✓ Date Called: ioveti /t/ &T, ; 6✓.te •/•! SS. Cr4A/A crj- re Special Instructions: _ • Date Wanted: t5"-7- /b a:m: Requester: D,G ...„,, 4 A / ,f . •.,11/ _ 4J..4 • Phone No: aOG- 2rr3' - _ S�4/ \ jj Approved per applicable codes. O Corrections required prior to approval. /0 • COMMENTS: A 4 • 0644z././e7 - _ ioveti /t/ &T, ; 6✓.te •/•! SS. Cr4A/A crj- re I, ,^,,, eve'r /. e%-- rte/„ (( D,G ...„,, 4 A / ,f . •.,11/ _ 4J..4 • ',5:_,) r.%P r.,i/•, / - 4fa:"C(. r 64.e T!J /NG✓ e / ige /Ab f7 R �� o�%<„i i /3 ✓ r , Q "P / "" / 0.00 REINSPECTION FEE R aid at 6300 Southcenter Blvd., UIRED. P'rior to inspection, fee must be uite 100. Call to schedule reinspection. 1t4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Qi0 -0'7c 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: t� spection: Type of Inspection: 5'u s- c-6,...` t 146 Addg s- ` n �i. ! 'J / / Date Called: Special Instructions: ../ Date Wanted: -� .--1. a p.m. Requester: Pho2 71 53 --SSG t Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 7 El $60.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 0'd -Oh, PERMIT NO. (206)431 -3670 Project: Type of Inspection: cw__ . 6.-11 / I ii . Address: _ '7 Yv(0o —' W Called: Special Instructions: - Date Wanted- �� a.m. /t7 P.m. Requester: Phone No: 'I,o (2 -17 3 -5G/ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: - r Inspecto / Date! /_2 U • 00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be did at 6300 South enter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit pro ofl, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `�� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: J % —A- -1 �( 'Qr-i . L 1 t t� 116 Address: _ ,4 '?S AJLdJLrVt/. Date Called: , 1( Special Instructions: Date Wanted: •4 - 25 -to P.M. Requester: — / f. --/ .g..: ,t, A74 ;A...) Phone No '7,0( -'7q3 -615‘/ Appt:Rer applicable codes. ElCorrections required prior to approval. ' T COMMEND, .p il . 4 6x''71`°~,- %tir(_ Z., )‘,5 -6c7-4,d k I .77,,.,,,, c . 4 s,��, �1,, 4 ,41t, 14114 �1„�. 44,�e' y dC i?% — / f. --/ .g..: ,t, A74 ;A...) I ._ -.__■. / -X - ttot Date`_, 0 ..l A' .1 0.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcent r Blvd., Suite 100. Call to schedule reinspection.'. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT N9,, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj t: % t ie_f UAv Jell .50 Type of I pection: - .fad, iti Addr� 7$ �1'`J J. ! I Date Called: Special Instructions: % Date Wanted: ',. a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspec r: Date: A ri $60.0 D REINSPECTION FEE REQUIJ ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • INSPECTION NUMBER ITNsPEcrION RECORD Retain°a copy with permit. PERMIT NUMBERS CITY OF TUKWILATIRE DEPARTMENT 444 Andover Park East; Tukwila, Wa. 98188 206 - 575 -4407 - - - - - - -- - - Project: Type of Inspection: [" e..4e: F via. Fire Alarm: Address: 3-7 5` A Pw Suite #: 1,05 Contact Person: 64.... v• u:, N � Monitor: A ha% Special Instructions: Phone No.: 204,, 167 - 5- d Approved per applicable' codes. Corrections required prior to approval. COMMENTS: /o1-.. alc. X..04 ._�. 1 Sip 4'e s ‘,/3.14 ( kaP 4t. ,4,10 Needs Shift Inspection: F Sprinklers: .I Fire Alarm: Hrs.: J. 0 Hood & Duct: Monitor: 44 / 1- 1-4.-- Pr f -Fire: Permits: Occupancy Type: • Inspector: .. F Date: c I t 0 Hrs.: J. 0 • n $80.00 REIN PECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. • Word /Inspe ti •i `,,.Record Form.Doc r.•::- • 1/13/06 T.F.D. Form F.P. 113 • . . INSPECTION NUMBER INSPECT ION RECORD Retain a copy with-permit c'76 PERMITINUMBERS CITY OF TUIONILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206-575-4407 Project: La e4 Type of Inspection: rem pa e,./ OX-40 -54oCit, Address: c 7.S" NV Suite #: zatir Contact Person: 1 Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: tves Ittr. 100 4 , F- re, 1,40,4e) Needs Shift Inspection: n4 ,e2 Sprinklers: '% - Fire Alarm: / Hood & Ducti, " Monitor: / Pre-Fire: . Permits: . . Occupancy Type:! Inspector: n4 ,e2 • ..I Date: .5771ja. Hrs.: • • / • • $80.00 REINSPECTION FEE REQUIRED. You Will. receive an invoice from ity of Tukwila Finance Department. .Call to schedule a reinspection. Word/InSpectiOn Recor- Fo .Doc . - l• 1/13/06 ki I . . • T.F.D. Form F.R. 113 4 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: EA) EA Sprinkle: Type of Inspection: 5/0," ,b4 ye L ;'I A, Address: 3-75- Suite #: Add. - Contact Person: Special Instructions: Occupancy Type: . Phone No:: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: i • lw - 'Needs Shift Inspection: Sprinkle: Are Alarm: Hood &# Duct :_ Monitor: Pre -Fire: Permits: Occupancy Type: . Inspector: --3 • Date: 5/7//e, Hrs.: $80.00 REINSPECTION FEE.REQUIRED. You will receive an invoice from th- City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 • • T.F.D. Form F.P. 113 l INSPECTION NUMBER INSPECTION'" RECORD Retain a copy with permit -4 1O' O7c 40- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: ,E4 tea v,404 i-tA, 3c.ed Type of Inspection: Sior,•,.bbe1 .e,,,- Cgva,,,,, \- a Address: (7 ' Suite #: p Contact Person: Pre -Fire: Permits: Special Instructions: Phone No.: p -- 4) Approved per applicable codes. • Corrections required prior to approval. COMMENTS: 0 _ Imo 1- 0, 444 5/s ,, , L- .t. ,W rreas - ' 4 • .1. • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date :. iiVi v . Hrs.: • / • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from • the City of Tukwila Finance Department. Call to schedule.a reinspection. Word/Inspection Record •Form.Doc 1/13/06 T.F.D. Form F.P. 113 I • • 1 G PI! PLAN EVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -076 DATE: 03 -1240 PROJECT NAME: RAINIER UNISERV COUNCIL (WEA) SITE ADDRESS: 575 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued EPART ENTS34111 v uilding ivision F.- Puf is 4916 Flo re Prevention Planning Division �1 Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IN- Incomplete n DUE DATE: 03-16 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 04 -134 0 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople �ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L8l to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name D P Inc General Contractors UBI No. 601515833 Phone 2063612989 Status Active Address 19909 Ballinger Way Ne License No. DPINCGC066BU Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/31/1994 State Wa Expiration Date 1/31/2012 Zip 98155 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTICC034MH Pattison Construction Co Llc Construction Contractor General Unused 7/8/1997 2/17/1998 Archived PATTICA066DQConstruction Pattison &Amp; Assoc Construction Contractor General Unused 3/18/19942/17/1998 01/31/2008 Archived DODSOPI101J6 Dodson Pattison Inc Construction Contractor General Unused 4/2/1990 3/26/1994 Archived ACECO "179L0 Ace Construction Construction Contractor Carpentry/Framing Painting / Wallcovering 6/20/1983 6/16/1986 Archived VANSND'176B0 Van's Northwest Drywall Construction Contractor Dry Wall Painting /Wallcovering 1/20/1983 11/1/1983 Archived ALLAMD'184BN All American Drywall Construction Contractor Dry Wall Painting / Wallcovering 1/15/19821/15/1983 Archived Business Owner Information Name Role Effective Date Expiration Date Dodson, William President 01/31/1994 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 DEVELOPERS STY & INDEMNITY CO 791078C 01/31/2008 Until Cancelled $12,000.0002/25 /2008 4 CBIC SA6377 01/31/2002 01/31/2008 01/31/2010 $12,000.00 01/09/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 OHIO CASUALTY INS CO BK01153724175 01/31/2009 01/31/2011 $1,000,000.0001 /22/2009 12 0010 CAS INS BK00953724175 01/31/2008 01/31/2009 $1,000,000.00 04/04/2008 https://fortress.wa.gov/lni/bbip/Print.aspx 03/31/2010 N Cn U w 0 0 0 0 0 N 0 w r) 0 0 a) a) 0 0 U L Q) 0 a) 0 0 co 0 N) cn -N N I CO Ul N I CO Ma ai vi U C .. Pa) ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FIN FLR FLUOR FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT ACOUSTICAL CEILING TILE ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC /CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR 1 I ABBREVIATIONS JT LL @TE LF MAX MECH MFR MIN MISC MTD MTL MW N/A NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTN R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TYP VCT VERT WI W/O WC wC JOINT BY LANDLORD AT TENANTS EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE OVEN NORTH / NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS / REMOVE / RELOCATE RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TYPICAL VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD NA • • • • O ® ® 11 AREA OF WORK N.I.C. LONGEST COMMON PATH: 62' N.I.C. NO CHANGE TO BUILDING AREA NO EXTERIOR WORK NO CORE /SHELL WORK NO STRUCTURAL WORK OCCUPANT LOAD CALCULATION TOTAL SUITE SQUARE FOOTAGE: (X) OCCUPANCY LOAD FACTOR: TOTAL: (1) EXIT REQUIRED; (1) EXIT PROVIDED 2,598 I 100 = 26 OCCUPANTS 2 I KEY PLAN, EXITING AND OCCUPANCY LOAD CA SECOND FLOOR PLAN 1/16" =1' -0" 0 5' 10' 20' 30' NORTH I Ytl Ytl Immi LCULATION PROVIDE, PER PLAN, 4' -0" WIDE ACOUSTICAL CEILING TILES CENTERED OVER PARTITION ABOVE HUNG CEILING AT DEMISING WALLS. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. 118" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS AT DEMISING WALLS. 1<111iMill iMIUSSf 'sum al! �msno a1a A SEISMIC BRACING PER 6/TI -1. 1/4" NON -COMB. WD FILLER UNDER MAIN RUNNERS CONTINUOUS CEILING GRID - DO NOT CUT. LINE OF CEILING GRID BEYOND, SEE R.C.P. CONT. 'L' METAL TRIM W/ PAPER WING CONT. 2 1/2" x 1 1/4" 25 GA. TRACK W/ (2) #10 SCREWS @ 24" O.C. 6" X 18 GA. METAL PLATE BLOCKING @ WALL HUNG ITEMS HEAD SECTION 2 1/2" x 25 GA. GALV. STEEL STUD @ 24" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. PLAN VIEW 5/8" GWB, TYPE 'X' EACH SIDE, TYP. BASE, AS SCHEDULED. - CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS 101 REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN. EMBEDMENT. BASE SECTION STANDARD PARTITION 12 MINKLER BLVD. ANDOVER PARK W. BLDG 3 hrY IISTRANDER Q BLVD. SOU THCEN r O MINK UPLAND R. MIDLAND DR. TRILAND DR. ER S BLVD. TE SEPARATE Pi: ,:oiT REQUIRED Bt' erMechan cc 1 3 I SITE PLAN NA 4 I VICINITY MAP NA EXISTING VERTICAL OR HORIZONTAL STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX I OMIT BRACING AT WALL LATERAL BRACING (STAGGERED) PER DETAIL ABOVE (TYP.) LATERAL WALL BRACING PLAN VIEW NTS 8' MAX . 2' MAX );)'TO END I II OF WALL TOP OF WALL NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. NA 6 I PARTITION HEAD BRACING DETAIL + n + + 21/2" X 25 GA. STL. STUDS 5/8" GWB, TYPE 'X', TYP. STEEL TUBE BRACING - SEE ISOMETRIC BELOW PLAN 9 "X31/2 "X21/4 "X3/16" METAL 1.' EACH SIDE SECURED TO STEEL TUBE & ANCHORED TO FLOOR AS REQUIRED NOTE: STEEL TUBE SUPPORT TO BE MAX. HEIGHT FOR PARTITION NA 7 I PARTIAL HEIGHT PARTITION ISOMETRIC SCOPE OF WORK TENANT IMPROVEMENT TO PART OF THE SECOND FLOOR FOR OFFICE USE TO INCLUDE DEMOLITION OF PARTITIONS AND CONSTRUCTION OF NEW PARTITIONS, DOORS, RELITES, CASEWORK AND OTHER FEATURES. AREA OF SUITE: 2,598 SQ.FT. OCCUPANCY TYPE: B CONSTRUCTION TYPE: VN SPRINKLERED BUILDING CODES: 2006 INTERNATIONAL BUILDING CODE (IBC) 2006 INTERNATIONAL FIRE CODE (IFC) 2006 UNIFORM PLUMBING CODE (UPC) 2006 INTERNATIONAL MECHANICAL CODE (IMC) 2008 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL #: 262304 -9143 LEGAL DESCRIPTION All that certain real property situated in the City of Tukwila, County of King State of Washington, being a portion of the east 1/2 of the northwest 1/4 of the southeast 1/4 of Sec. 26, T.23N, R.4E, W.M., and being more particularly described as follows: BEGINNING at the intersection of the northerly line of said southeast 1/4 with the westerly margin of Andover Park West (59th Avenue South), distant along said northerly line N88 °05'42 "W 1369.34 feet from the northwest comer of said south- east quarter; thence from said POINT OF BEGINNING alond said westerly margin 501 °47'29 "W 451.30 feet; thence leaving said westerly margin tangent to the preceding course along the arc of a curve to the right having a radius of 50.00 feet and a central angle of 90 °06'49 ", an arc length of 78.64 feet to a point on a line that is parallel to and 501.40 southerly of the northerly line of said southeast 1/4; thence along said parallel line N88 °05'42 "W 180.90 feet to a point on a line that is parallel with and 261.00 feet westerly of the east line if said east 1/2; thence along last said parallel line N01 °47'29 "E 136.00 feet to a point on a line that is parallel to and 365.40 feet southerly of the northerly line of said southeast 1/4; thence along last said parallel line S88 °05'42 "E 37.50 feet to a point on a line that is parallel to and 223.50 feet westerly of the east line of said east 1/2; thence along last said parallel line N01 °47'29 "E 100.00 feet to a point on a line that is parallel to and 265.40 feet southerly of the northerly line of said southeast 1/4; thence along last said parallel line N88 °05'42 "W 12.50 feet to a point on a line that is parallel to and 236.00 feet westerly of the east line of said east 1/2; thence along last said parallel line N01 °47'29 "E 265.40 feet to a point on the northerly line of said southeast 1/4; thence along said northerly line S88 °05'42 "E 206.00 feet to the POINT OF BEGINNING and containing 2.408 acres of land more or less. ADDRESS: 575 ANDOVER PARK WEST PROJECT DIRECTORY TENANT WEA RANIER UNISERV BUILDING REPRESENTATIVE AMERICAN MANAGEMENT SERVICES dba PINNACLE 810 THIRD AVE, SUITE 140 CONTACT: TAMARA GENZALE TELEPHONE: (206) 903 -0662 EMAIL: tgenzale @prmc.com DESIGNER MARVIN STEIN AND ASSOCIATES, LLC 2221 FIFTH AVENUE SEATTLE, WASHINGTON 98121 CONTACT: GEORGE GOODFELLOW PHONE: (206) 441 -1449 FAX: (206) 441 -4361 EMAIL: g.goodfellow @marvinstein.com GENERAL CONTRACTOR TBD FILE COPY Permit tio., 0" O1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize t'rtc violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged:. By sc!f\ftimr.fiNCV\ ‘k- Date: _ 0 City Of 1111JILDING DIVISION HVAC AND FIRE LIFE SAFETY NOTES HVAC 1. RECONFIGURE AS REQUIRED FOR ALTERATIONS. 2. RE- BALANCE HVAC SYSTEM. REVISIONS No changes shall be made to the scope 3. CLEAN ALL EXISTING GRILLES. Of Work without prior approval of Tukwila Building Division. 4. VERIFY AND RELOCATE THERMOSTAT(S) AS NECESSARY. NOTE': revisions will require a new plan submittal tr.1 may include additional plan review fees. j FIRE LIFE SAFETY 1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO BE PER CODE. 2. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. GENERAL NOTES 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS & SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING CONTRACT DOCUMENTS. 5. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CFNTFRI INF OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. . RE IEWED FOR CODE COMPLIANCE APPROVED MAR 31 2010 6. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTED OTHERWISE. 7. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDIM JURISDICTIONS WHERE APPLICABLE. 8. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 9. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITIONS SO THAT FINISHES REMAIN FLU: AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. G PPJ H6 10. PROVIDE LEVELLING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE. SHEET INDEX TI -1 COVER SHEET TI -2 DEMOLITION PLAN TI -3 CONSTRUCTION PLAN TI-4 REFLECTED CEILING PLAN TI -5 ELEVATIONS & SECTION jfy of Tukwila DING DIVISION RECEIVED MAR 12 2010 PERMIT CENTER DlOOTh SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TU K WI LA, WA Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB /CL CHECKED BY: SN /GG JOB NO.: 99135.045 NO. REVISIONS INDICATED THUS A DATE BY PERMIT SET FOR APPROVAL PRICING /CONSTRUCTION SET 03/08/10 LB 03/11/10 CL TENANT: WEA RAINIER UNISERV SHEET TITLE: COVER SHEET NA 8 PROJECT INFORMATION NA REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2010. TI -1 OF 5 N 01 0 0 01 0 0 0 0 0 U N COO N) 0, C 0 0 U) 0 L. 0 U N a) 0 t 0 C� N I m NN U O I mm .,.3� '0U 0 q) L L pox 0 10 r Li r== =d r II II II 111 NIC NIC 0 0 0 ,WON Eft I -, I I 0 MEN DEMOLITION LEGEND DEMOLITION NOTES EXISTING BUILDING CORE AREA (N.I.C.) EXISTING PARTITION TO REMAIN. EXISTING CORRIDOR PARTITION TO REMAIN. EXISTING CONSTRUCTION TO BE DEMOLISHED. 1. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM AND SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND BUILDING OWNER / MANAGEMENT. 3. SEE TI -1 FOR GENERAL NOTES. 4. SAVE REMOVED DOORS ON -SITE FOR POSSIBLE RELOCATION. 5. REMOVE FLOORING AND BASE THROUGH -OUT. DEMOLITION KEYNOTES OREMOVE PORTION OF PARTITION TO ALLOW FOR INSTALLATION OF NEW GLASS RELITE. SEE CONSTRUCTION PLAN ON TI -3. SECOND FLOOR PLAN 1/8" =1' -0" 0 5' 10' 20' 30' NORTH REVIEWED FOR CODE COMPLIANCE APPROVED MAR 31 2010 City of Tukwila ROWING DIVISION RECEIVED MAR 12 2010 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TU K WI LA, WA Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB /CL CHECKED BY: SN /GG JOB NO.: 99135.045 NO. REVISIONS INDICATED THUS A DATE BY PERMIT SET FOR APPROVAL 03/08/10 LB PRICING /CONSTRUCTION SET 03/11 /10 CL TENANT: bi WEA RAINIER UNISERV SHEET TITLE: DEMOLITION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2010. TI -2 OF 5 N 0 1 0_ w C 0 C 0 U CT. C 0 U N w cri COM 3- 0 Cr 0 U L CO 0 No 1m CD (NI CD 1 CO CO .0•• sue 0co pox CONF. RM 12101 �— — PTN./MUL. OFFICE 1 209 — PTN./MUL. OFFICE 208 • OFFICE 1 207 I OFFICE 1 206 I OFFICE 12CTI • E 8' -O" CONSTRUCTION LEGEND WORK RM 202 SERVER/TEL 1 203 I OFFICE 1 204 I ■ I N F -H EXISTING BUILDING CORE AREA (N.I.C.) EXISTING PARTITION TO REMAIN. EXISTING CORRIDOR PARTITION TO REMAIN. NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 5/TI -1. NEW B/S PARTIAL HEIGHT PARTITION AT 3'-4" AFF. SEE DETAIL 7/TI -1. NEW B/S FULL - HEIGHT TEMPERED SAFETY GLASS RELITE (WIDTH PER PLAN). NEW B/S GLASS RELITE AND FRAME. TOP OF FRAME TO MATCH AND ALIGN WITH TOP OF DOOR FRAME WITH SILL AT 38" AFF. (WIDTH PER PLAN). NEW BUILDING STANDARD CASEWORK. ALIGN. EXISTING CORRIDOR NIC CONSTRUCTION NOTES 1. PROVIDE MINIMUM FURRING AROUND COLUMNS, IF NOT ALREADY EXISTING. CONSTRUCTION KEYNOTES NIC e e e WOMEN MEN 0 0 0 J SECOND FLOOR PLAN 1/8" =1' -0" 0 5' 10' 0 PROVIDE NEW 24" X 80" TEMPERED SAFETY GLASS INSERT IN EXISTING DOOR. 20' DOOR SCHEDULE EL 30' NORTH O' E 6 ", UNLESS OTHERWISE NOTED DOOR NUMBER TYPE OF DOOR A. NEW B/S 3' -0" W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S WOOD FRAME. B. NEW PAIR OF B/S 3' -0 "W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S WOOD FRAME. C. NEW B/S 3' -0 "W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S WOOD FRAME WITH 24" X 80" TEMPERED SAFETY GLASS INSERT. HARDWARE a. B/S LATCHSET. b. B/S LOCKSET c. B/S DOUBLE DOOR HARDWARE WITH LATCHSET d. B/S LOCKSET & CLOSER. EXISTING DOOR TO REMAIN CODE REVIEWED V�,lD� APPROVED MAR 31 2010 ofTukwila Ri.11LDICityNG DIVISION RECEIVED MAR 12 2010 PERMITCENTER SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TU K WI LA, WA Marvin Ste planning sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB /CL CHECKED BY: SN /GG JOB NO.: 99135.045 NO. REVISIONS INDICATED THUS n DATE BY PERMIT SET FOR APPROVAL 03/08/10 LB PRICING /CONSTRUCTION SET 03/11/10 CL TENANT: WEA RAINIER UNISERV ttdI - 07 to SHEET TITLE: CONSTRUCTION PLAN REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2010. TI -3 OF 5 CO U w 0 0 0 0 N CO) La CO w 0 0 U) 0 0 U L Q) 0 a) co ■ N I 0 V7 N 00 - mm �, 'cn U U ao L L ox (ED n 210 209 208 207 1 206 1 205 1 (4) 4EQ EQ. L -- EQrELT 1 202 1 203 1 204 r , NIC NIC WOVEN MEN EL.. CEILING LEGEND EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT EMERGENCY LIGHT FIXTURE, (CONCEPTUAL ONLY -SEE GENERAL NOTE #2). RELOCATED 2'X4' RECESSED FLUORESCENT EMERGENCY LIGHT FIXTURE, (CONCEPTUAL ONLY -SEE GENERAL NOTE #2). r-----1 EXISTING 2X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE L____J RELOCATED. V I RELOCATED BIS 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES. ® (N)(R) EXISTING, U.N.O., BIS ILLUMINATED EXIT SIGN. (DIRECTIONAL WHERE INDICATED) (N = NEW) (R= RELOCATED EXISTING) i .(N) EXISTING, U.N.O., BIS LIGHT SWITCH. ( N = NEW) SECOND FLOOR PLAN 1/8" =1' -0" 0 5' 10' REFLECTED CEILING NOTES 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUITS, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL VERIFY EXISTING EMERGENCY PATHWAY LIGHTING AND ADJUST AS REQUIRED. PROVIDE ONE FOOT CANDLE OF ILLUMINATION AT FLOOR LEVEL ALONG THE EXIT PATHWAY. SUBJECT TO FIELD INSPECTION. 3. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 5. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTING AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 6. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 7. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 20' REFLECTED CEILING NOTES 30' NORTH OREMOVE EXISTING EXIT SIGN AND RELOCATE, AS SHOWN. LIGHTING CALCULATION 2,598 TOTAL S.F. x 1 WATT PER S.F. = 2,598 ALLOWABLE WATTS. TOTAL PROPOSED WATTAGE IS 2,598. NO WATTAGE CHANGE ALTERATION IS 47% WHICH IS LESS THAN THE 60% ALLOWED. REVIEWED FOR CODE COMPLIANCE 4pDRoVED MAR 31 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 12 2010 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TU K WI LA, WA Marvin Ste ° '1sociates, LLC planning v design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB /CL CHECKED BY: SN /GG JOB NO.: 99135.045 NO REVISIONS INDICATED THUS A DATE BY PERMIT SET FOR APPROVAL 03/08/10 LB PRICING /CONSTRUCTION SET 03/11/10 CL TENANT: WEA RAINIER UNISERV bi SHEET TITLE: REFLECTED CEILING PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2010. TI-4 OF 5 GWB PARTIAL HEIGHT PARTITION (PAINT AS SCHEDULED) 3/4" P -LAM FILL (BOTH SIDES). B/S P -LAM CASEWORK W/ 4" TOEKICK 1" EQ. \� /" OF1EN / /" I " i j /" ' \ i '-..._ EQ. ELEVATION 3/8" =1' -0" EQ. EQ. 1 1/2' FRAMED OPENING WITH FRAME TO MATCH B/S RELITE FRAME FACE OF GWB P -LAM ADJUSTABLE SHELF GWB PARTIAL HEIGHT PARTITION (PAINT AS SCHEDULED) (6) EQ. B/S P -LAM COUNTERTOP AND BACKSPLASH. N 1 1/2" THICK P -LAM FILLER / \ / \ / \ /" \ sx V= INSULATE WRAP @ EXPOSED SUPPLY & DRAIN LINES N n i \ / > /" \ / N EQ. EQ. EQ. 36" EQ. EQ. EQ. ELEVATION 3/8" =1' -0" GWB (PAINT AS SCHEDULED.) CEILING B/S FRAME TO MATCH EXISTING. CONTRACTOR TO PROVIDE ALLOWANCE OF $1500.00 FOR SHADE OR SIMILIAR - COORDINATE WITH TENANT AND OWNER. 1" B/S WALL MOUNTED METAL SUPPORT GWB (PAINT AS SCHEDULED.) ° ° ° ° ° ° ° 0 0 0 0 ° ° 0 d d 0 MAX. ° 0 /. INTERIOR ° 0 DIM. 0 0 0 0 0 0 0 0 0 A B/S P -LAM COUNTERTOP WITH SELF -EDGE. PROVIDE BLOCKING AS REQUIRED, TYP. BASE, AS SCHEDULED. N SECTION 1 112 " =1' -0" B/S P -LAM UPPER CABS. WITH DOORS AND (2) ADJ. SHELVES, TYP. FACE OF GWB B/S A.D.A.-APPROVED P -LAM SINK CABINET (NO BOTTOM @ BASE) WITH B/S A.D.A.-COMPLIANT SINK & FAUCET. B/S P -LAM LOWER CABS. WITH DOORS, DRAWERS, (1) ADJ. SHELF AND 4" TOE KICK, TYP. NOTE: PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. PROVIDE FILLER FOR UPPER & LOWER CABINET AS NECESSARY PLAN DETAIL 1 112 " =1' -0" 1" \ = == / (5) EQ. / N =I =_ == 7/' '1U1/ // N = = = /" NY = ELEVATION 3/8" =1' -0" LOW WALL BELOW LINE OF TRANSACTION TOP. CASEWORK BELOW IL i- - - -- 1 i FACE OF GWB B/S P -LAM UPPER CABS. WITH DOORS AND (2) ADJ. SHELVES, TYP. B/S P -LAM COUNTERTOP AND BACKSPLASH. B/S P -LAM LOWER CABS. WITH DOORS, DRAWER, (1) ADJ. SHELF AND 4" TOE KICK, TYP. NOTE: PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS. PROVIDE FILLER FOR UPPER & LOWER CABINET AS NECESSARY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 31 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 12 2010 PERMITCENTER SOUTHCENTER CORPORATE SQUARE BUILDING 3 575 ANDOVER PARK WEST TU K WI LA, WA Marvin Ste «.sociates, LLC planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: LB /CL CHECKED BY: SN /GG JOB NO.: 99135.045 NO. REVISIONS INDICATED THUS A DATE BY PRICING /CONSTRUCTION SET 03/11 /10 CL TENANT: WEA RAINIER UNISERV 0-7 SHEET TITLE: ELEVATIONS & SECTION REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2010. TI -5 OF 5