HomeMy WebLinkAboutPermit D10-076 - RAINIER UNISERV COUNCIL (WEA) - TENANT IMPROVEMENTRAINIER UNISERV
COUNCIL (WEA)
575 ANDOVER PK W
D10 -076
City'Of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2623049144
Address: 575 ANDOVER PK W TUICW
Suite No:
DEVELOPMENT PERMIT
Permit Number: D10-076
Issue Date: 03/31/2010
Permit Expires On: 09/27/2010
Tenant:
Name: RAINIER UNISERV COUNCIL (WEA)
Address: 575 ANDOVER PK W , TUKWILA WA
Owner:
Name: SOUTHCENTER CORPORATE SQUAR
Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111
Phone:
Contact Person:
Name: TAMARA GENZALE
Address: 635 ANDOVER PK W SUITE 107 , TUKWILA WA 98188
Phone: 206 - 575 -3080
Contractor:
Name: D P INC GENERAL CONTRACTORS
Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155
Phone: 206 - 361 -2989
Contractor License No: DPINCGC066BU
Expiration Date: 01/31/2012
DESCRIPTION OF WORK:
2ND FLOOR TENANT IMPROVEMENTTO INCLUDE DEMOLITION OF EXISTING PARTITIONS, DOORS AND OTHER FEATURES
Value of Construction: $15,000.00 Fees Collected: $622.10
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006
Type of Construction: V -B Occupancy per IBC: 0008
* *continued on next page **
doc: IBC -10/06
D10 -076 Printed: 03 -31 -2010
City ai'ukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: D 1 0-0 76
Issue Date: 03/31/2010
Permit Expires On: 09/27/2010
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: 3, t3 t -C O
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development ermit.
Signature: 1 ` Date: �� 1 ��
Print Name:
cAnot Vl V1 vin V1. V/11
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC -10/06
D10 -076 Printed: 03 -31 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 2623049144
Address:
Suite No:
Tenant:
575 ANDOVER PK W TUKW
RAINIER UNISERV COUNCIL (WEA)
Permit Number:
Status:
Applied Date:
Issue Date:
D10 -076
ISSUED
03/12/2010
03/31/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition nibble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
14: VALIDITY.OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Cond -10/06
D10 -076 Printed: 03 -31 -2010
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
15: ** *FIRE DEPARTMENT CONDITIONS * **
16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
doc: Cond -10/06
D10 -076 Printed: 03 -31 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. ( THE OCCUPANT LOAD
FACTOR FOR THE LARGE CONFERENCE ROOM IS 15, NOT 100 AS FOR THE OFFICE AREAS. THEREFORE THE TOTAL OCCUPANT LOAD
EXCEEDS
49 AND EMERGENCY EGRESS LIGHTING AND EXIT SIGNAGE IS REQUIRED.)
30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
39: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite,
room or apartment number in a conspicuous place near the main entry door. (IFC 505.1)
40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
doc: Cond -10/06
D10 -076 Printed: 03 -31 -2010
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes
such condition or violation.
43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila
(206)575 -4407.
* *continued on next page **
does not imply approval of
Fire Prevention Bureau at
doc: Cond -10/06 D10 -076
Printed: 03 -31 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: " ' _0 V\ . Date:
Print Name: 7 I V,- 11(101-W
ordinances governing
or local laws regulating
doc: Cond -10/06 D10 -076
Printed: 03 -31 -2010
CITY OF TUKWIL1P
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: //www. ci. tukwila. wa. us
•
Building Permit No. 10 -0 7p
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: p C1 /eV Pelt/Y- we q
1201111. I Y / L p V cculoi W b/61l
Tenant Name:
King Co Assessor's Tax No.:
Property Owners Name: KAe i weir eV Pel (111G
,2,40-7,w4-1 I q'k
Suite Number: Floor:
New Tenant:
Yes ❑..No
Mailing Address: ((GI I -?Mo r \ v ,V 1. ,svi f' I v~I 0 SCU €,
City
State
c1c114
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: TOI YVV Y1I G-elnol 10 Day Telephone::
t iV I
Mailing Address: U%f (1o/eV PUv(L Wet, 107 � //
(M "1
n City
E -Mail Address: fi�evyialeC&p(nIC4 Ci1't'1 Fax Number:
30W
vvft qt. r g
Zip
ip
w 7c I (c1 c
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
112-21)
Mailing Address:
Zip
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: On WV f t^ Y V �S i(/)a s �^
Mailing Address: 2' 7/ I VAT) 1 r 1 V 1% €i SPott'e 11'v fr 'T %I
�_�q n I ,,� City State Zip
Contact Person: c-� 1 V `�i 14v 1 V C1 �l) Day Telephone: 7ia0 � I I `-1
E -Mail Address: ' • YOVO VV 0 Q nnn1/00 S iV1 •COW Number: `?/0 b 9'4 I 4 3 b
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applicetions\Pmms- Applicatiau On Line \2009 Applications \1-2009 - Permit Application doe
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFOION - 206 - 431 -3670
Valuation of Project (contractor's bid price): $ fS S 0 DO Existing Building Valuation: $
Scope of Work (please provide detailed information): 2incl floc) V lei\ Vt IV pv- ovtel' IeV 1 k- tO
'maxie 6e6vo1 iov' of- exi4incj ns,c1oovc (V O -Ivey -ffiivves.
Will there be new rack storage? ❑ Yes
Qj. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
El Sprinklers Er- Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes gi No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H.\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised. 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1St Floor
2nd Floor
t'''7
-�l 1 V "J
\CP,
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
El Sprinklers Er- Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes gi No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H.\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised. 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
AGENT: _
Date: , l 17/ 1 U
Print Name: 1 r xIVo /17.1/ 74le�/ }, Day Telephone: 2.00- r��aS' �f �g0
Mailing Address: b9--}g �"IweV I�1►' �f-` SI cvi , of 1 "5-� V `,� V V A � g-1 D5
City State Zip
Date Application Accepted:
Date Application Expires:
Staff Initials:
H: Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application. don
Revised: 1 -2009
bh
Page 6 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049144 Permit Number: D10-076
Address: 575 ANDOVER PK W TUKW Status: PENDING
Suite No: Applied Date: 03/12/2010
Applicant: RAINIER UNISERV COUNCIL (WEA) Issue Date:
Receipt No.: R10 -00453
Payment Amount: $622.10
Initials: WER Payment Date: 03/12/2010 03:58 PM
User ID: 1655 Balance: $0.00
Payee: SOUTHCENTER CORP SQUARE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 2886 622.10
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $622.10
374.30
243.30
4.50
doc: Receipt -06 Printed: 03 -12 -2010
#9
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
C�
orO-o')(
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION �-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
P� r Cf. V �!
TYPe of trtispectio.
i
b
Address_ ;_ �A Ve - 141;
KKK
Date Called:
Special Instructions:
WJ
6 ` 2 q�
2 4 —� ��� _ ti ! r
Date Wanted: ` .
G
l J
a.m,2
p.m.
Requester:
Phone 7No: (0
/,,
SCo
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
P
Inspe Sct r:�1'
Date:
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: (Date:
1
.. M!'1 _ _ _ _ ,F 4 Mf�i— _...._L- ...,cYv eteh4L.tsL4i• —rMi
INSPECTION RECORD
Retain a copy with permit
INSP CTION NO. .PEERMIT NO:
CITY OF TUKWILA BUILDING DIVISION _p4(
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
LAI
Type of Inspectio
��
7
Address:
5 11 vugojei J
Date Called:
Special Instructions:
D4�. ^'4 — d (
Date Wanted
I/ D � to
am.
--irrn.
Requester:
Phone No:
2,®6 -'773 --9156
Approved per applicable codes.
10 Corrections required prior to approval.
COMMENTS:
f
.Lll ii(A/ f'. N•9/ -- A/Fee/017
VVIYe0, ddelb,047, 120./Ale°
— .cam,cs ,it/4-
IA
Date
0.00 REINSPECTION iEE R[1IRED. Prior to inspection, fee must be
aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO. '
INSPECTION RECORD
Retain a copy with permit ■iO -6:96
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pro' ct:
"A 1n . *// 2/� /h:Sa y
Type of Inspection:
• L47/ Ai- -
F "
I
Address:
6-7 4,1-( 92-4°/?/‘ C.✓
Date Called:
ioveti
/t/ &T, ; 6✓.te •/•! SS. Cr4A/A crj- re
Special Instructions:
_
•
Date Wanted:
t5"-7- /b
a:m:
Requester:
D,G ...„,, 4 A / ,f . •.,11/ _ 4J..4
•
Phone No:
aOG- 2rr3' -
_
S�4/
\ jj Approved per applicable codes. O Corrections required prior to approval. /0
•
COMMENTS: A 4 •
0644z././e7 - _
ioveti
/t/ &T, ; 6✓.te •/•! SS. Cr4A/A crj- re
I, ,^,,, eve'r /. e%-- rte/„ ((
D,G ...„,, 4 A / ,f . •.,11/ _ 4J..4
•
',5:_,) r.%P r.,i/•, / - 4fa:"C(.
r 64.e T!J /NG✓ e / ige /Ab f7 R ��
o�%<„i
i
/3 ✓ r , Q "P / ""
/
0.00 REINSPECTION FEE R
aid at 6300 Southcenter Blvd.,
UIRED. P'rior to inspection, fee must be
uite 100. Call to schedule reinspection.
1t4
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
Qi0 -0'7c
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
t�
spection:
Type of Inspection:
5'u s- c-6,...` t 146
Addg s-
` n �i. !
'J /
/
Date Called:
Special Instructions:
../
Date Wanted:
-� .--1. a p.m.
Requester:
Pho2 71 53 --SSG t
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Date: 7
El $60.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
0'd -Oh,
PERMIT NO.
(206)431 -3670
Project:
Type of Inspection:
cw__ . 6.-11
/
I ii .
Address: _
'7 Yv(0o —' W
Called:
Special Instructions:
-
Date Wanted-
��
a.m.
/t7 P.m.
Requester:
Phone No:
'I,o (2
-17
3 -5G/
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
-
r
Inspecto
/
Date! /_2 U •
00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be
did at 6300 South enter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
pro ofl,
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION `��
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
Type of Inspection: J % —A- -1
�( 'Qr-i . L 1 t t� 116
Address:
_ ,4
'?S AJLdJLrVt/.
Date Called:
,
1(
Special Instructions:
Date Wanted:
•4 - 25 -to P.M.
Requester:
— / f. --/ .g..: ,t, A74 ;A...)
Phone No
'7,0(
-'7q3 -615‘/
Appt:Rer applicable codes.
ElCorrections required prior to approval. ' T
COMMEND, .p il .
4
6x''71`°~,- %tir(_ Z., )‘,5 -6c7-4,d k
I
.77,,.,,,, c . 4 s,��, �1,, 4 ,41t, 14114
�1„�.
44,�e'
y
dC i?%
— / f. --/ .g..: ,t, A74 ;A...)
I
._ -.__■. / -X
-
ttot
Date`_, 0
..l A' .1
0.00 REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be
aid at 6300 Southcent r Blvd., Suite 100. Call to schedule reinspection.'.
Receipt No.: Date:
INSPECTION RECORD
Retain a copy with permit
INSP CTION NO. PERMIT N9,,
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Proj t: % t
ie_f UAv Jell .50
Type of I pection: -
.fad, iti
Addr� 7$ �1'`J J. ! I
Date Called:
Special Instructions:
%
Date Wanted:
',. a.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspec r:
Date: A
ri $60.0 D REINSPECTION FEE REQUIJ ED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
•
INSPECTION NUMBER
ITNsPEcrION RECORD
Retain°a copy with permit.
PERMIT NUMBERS
CITY OF TUKWILATIRE DEPARTMENT
444 Andover Park East; Tukwila, Wa. 98188 206 - 575 -4407
- - - - - - -- - -
Project:
Type of Inspection: ["
e..4e:
F
via.
Fire Alarm:
Address: 3-7 5` A Pw
Suite #: 1,05
Contact Person:
64.... v• u:, N
�
Monitor:
A ha%
Special Instructions:
Phone No.: 204,, 167
- 5-
d
Approved per applicable' codes.
Corrections required prior to approval.
COMMENTS:
/o1-..
alc.
X..04
._�.
1
Sip 4'e s ‘,/3.14 (
kaP 4t.
,4,10
Needs Shift Inspection:
F
Sprinklers: .I
Fire Alarm:
Hrs.:
J. 0
Hood & Duct:
Monitor:
44 /
1- 1-4.--
Pr f -Fire:
Permits:
Occupancy Type:
•
Inspector: ..
F
Date: c
I t 0
Hrs.:
J. 0
•
n $80.00 REIN PECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
• Word /Inspe ti •i `,,.Record Form.Doc
r.•::- •
1/13/06
T.F.D. Form F.P. 113
•
. .
INSPECTION NUMBER
INSPECT ION RECORD
Retain a copy with-permit
c'76
PERMITINUMBERS
CITY OF TUIONILA FIRE DEPARTMENT
444 Andover Park East, Tukwila. Wa. 98188 206-575-4407
Project: La e4
Type of Inspection:
rem pa e,./ OX-40 -54oCit,
Address: c 7.S" NV
Suite #: zatir
Contact Person: 1
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
tves Ittr. 100 4 ,
F- re, 1,40,4e)
Needs Shift Inspection:
n4 ,e2
Sprinklers:
'% -
Fire Alarm:
/
Hood & Ducti,
"
Monitor:
/
Pre-Fire:
.
Permits:
. .
Occupancy Type:!
Inspector:
n4 ,e2
• ..I
Date: .5771ja.
Hrs.: • •
/
•
•
$80.00 REINSPECTION FEE REQUIRED. You Will. receive an invoice from
ity of Tukwila Finance Department. .Call to schedule a reinspection.
Word/InSpectiOn Recor- Fo .Doc . - l• 1/13/06
ki
I
. .
• T.F.D. Form F.R. 113
4
3
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188
206- 575 -4407
Project: EA) EA
Sprinkle:
Type of Inspection:
5/0," ,b4 ye L ;'I A,
Address: 3-75-
Suite #:
Add. -
Contact Person:
Special Instructions:
Occupancy Type: .
Phone No::
Approved per applicable codes.
nCorrections required prior to approval.
COMMENTS:
i
•
lw -
'Needs Shift Inspection:
Sprinkle:
Are Alarm:
Hood &# Duct :_
Monitor:
Pre -Fire:
Permits:
Occupancy Type: .
Inspector:
--3
•
Date: 5/7//e,
Hrs.:
$80.00 REINSPECTION FEE.REQUIRED. You will receive an invoice from
th- City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc
1/13/06 •
• T.F.D. Form F.P. 113
l
INSPECTION NUMBER
INSPECTION'" RECORD
Retain a copy with permit
-4
1O' O7c
40-
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407
Project: ,E4 tea v,404 i-tA, 3c.ed
Type of Inspection:
Sior,•,.bbe1 .e,,,- Cgva,,,,,
\-
a
Address: (7 '
Suite #: p
Contact Person:
Pre -Fire:
Permits:
Special Instructions:
Phone No.:
p
-- 4)
Approved per applicable codes.
•
Corrections required prior to approval.
COMMENTS:
0 _ Imo
1- 0, 444 5/s ,, , L- .t. ,W rreas
- ' 4
• .1.
•
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
Date :.
iiVi v .
Hrs.:
• /
• $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from •
the City of Tukwila Finance Department. Call to schedule.a reinspection.
Word/Inspection Record •Form.Doc 1/13/06
T.F.D. Form F.P. 113
I
• •
1 G PI!
PLAN EVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -076 DATE: 03 -1240
PROJECT NAME: RAINIER UNISERV COUNCIL (WEA)
SITE ADDRESS: 575 ANDOVER PK W
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
EPART ENTS34111 v
uilding ivision F.-
Puf is 4916 Flo
re Prevention Planning Division �1
Structural
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
IN-
Incomplete
n
DUE DATE: 03-16 -10
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
DUE DATE: 04 -134 0
Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople �ter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L8l to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name D P Inc General Contractors UBI No. 601515833
Phone 2063612989 Status Active
Address 19909 Ballinger Way Ne License No. DPINCGC066BU
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 1/31/1994
State Wa Expiration Date 1/31/2012
Zip 98155 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
License
Name
Type
Specialty 1
Specialty 2
Effective
Date
Expiration
Date
Status
PATTICC034MH
Pattison
Construction
Co Llc
Construction
Contractor
General
Unused
7/8/1997
2/17/1998
Archived
PATTICA066DQConstruction
Pattison
&Amp;
Assoc
Construction
Contractor
General
Unused
3/18/19942/17/1998
01/31/2008
Archived
DODSOPI101J6
Dodson
Pattison Inc
Construction
Contractor
General
Unused
4/2/1990
3/26/1994
Archived
ACECO "179L0
Ace
Construction
Construction
Contractor
Carpentry/Framing
Painting / Wallcovering
6/20/1983
6/16/1986
Archived
VANSND'176B0
Van's
Northwest
Drywall
Construction
Contractor
Dry Wall
Painting /Wallcovering
1/20/1983
11/1/1983
Archived
ALLAMD'184BN
All
American
Drywall
Construction
Contractor
Dry Wall
Painting / Wallcovering
1/15/19821/15/1983
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
Dodson, William
President
01/31/1994
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
DEVELOPERS STY &
INDEMNITY CO
791078C
01/31/2008
Until Cancelled
$12,000.0002/25
/2008
4
CBIC
SA6377
01/31/2002
01/31/2008
01/31/2010
$12,000.00
01/09/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
13
OHIO CASUALTY
INS CO
BK01153724175
01/31/2009
01/31/2011
$1,000,000.0001
/22/2009
12
0010 CAS INS
BK00953724175
01/31/2008
01/31/2009
$1,000,000.00
04/04/2008
https://fortress.wa.gov/lni/bbip/Print.aspx
03/31/2010
N
Cn
U
w
0
0
0
0
0
N
0
w
r)
0
0
a)
a)
0
0
U
L
Q)
0
a)
0
0
co
0 N)
cn
-N
N
I CO
Ul
N
I
CO Ma
ai vi
U
C ..
Pa)
ACT
ADJ
AFF
ALT
ALUM
APPROX
BLDG
BLKG
B/S
CAB
CLR
CLG
CL
COL
COMM
COMP
CONST
CONT
CPT
CT
DIA
DIM
DR
DW
DWG
E
EA
ELEC
ELEC'L
ELEV
EXIST
EXT
FIN
FLR
FLUOR
FR
FT
FURN
GA
GALV
GD
GL
GWB
HC
HDW
HM
HT
HVAC
IN
INCL
INSUL
INT
ACOUSTICAL CEILING TILE
ADJACENT / ADJUSTABLE
ABOVE FINISH FLOOR
ALTERNATE
ALUMINUM
APPROXIMATELY
AT
BUILDING
BLOCKING
BUILDING STANDARD
CABINET
CLEAR/CLEARANCE
CEILING
CENTERLINE
COLUMN
COMMUNICATION
COMPOSITION
CONSTRUCTION
CONTINUOUS
CARPET
CERAMIC /CONCRETE TILE
DIAMETER
DIMENSION
DOOR
DISHWASHER
DRAWING
EXISTING / EAST
EACH
ELECTRIC
ELECTRICAL
ELEVATION (VIEW)
EXISTING
EXTERIOR
FINISH
FLOOR
FLUORESCENT
FIRE RATED
FEET
FURNISH / FURNISHINGS
GAUGE
GALVANIZED
GARBAGE DISPOSAL
GLASS / GLAZING
GYPSUM WALL BOARD
HOLLOW CORE
HARDWARE
HOLLOW METAL
HEIGHT
HEATING, VENTILATING,
AIR CONDITIONING
INCH
INCLUDE
INSULATION
INTERIOR
1 I ABBREVIATIONS
JT
LL @TE
LF
MAX
MECH
MFR
MIN
MISC
MTD
MTL
MW
N/A
NIC
NO
NOM
NTS
OC
OPNG
OPP
ORIG
PERM
PL
PLAM
PLYWD
PR
PTN
R
RB
REF
REINF
REQ'D
REV
RM
RO
S
SCHED
SC
SECT
SIM
SPEC
SQ
STD
STL
STOR
SUSP
TEL
TYP
VCT
VERT
WI
W/O
WC
wC
JOINT
BY LANDLORD AT TENANTS EXPENSE
LINEAL FOOT
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MOUNTED
METAL
MICROWAVE OVEN
NORTH / NEW
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OPENING
OPPOSITE
ORIGINAL
PERMANENT
PLATE
PLASTIC LAMINATE
PLYWOOD
PAIR
PARTITION
RADIUS / REMOVE / RELOCATE
RUBBER BASE
REFRIGERATOR
REINFORCING
REQUIRED
REVISION / REVERSE
ROOM
ROUGH OPENING
SOUTH
SCHEDULE
SOLID CORE
SECTION
SIMILAR
SPECIFICATION
SQUARE
STANDARD
STEEL
STORAGE
SUSPENDED
TELEPHONE
TYPICAL
VINYL COMPOSITION TILE
VERTICAL
WEST
WITH
WITHOUT
WALLCOVERING
WOOD
NA
•
•
•
•
O ® ® 11
AREA OF WORK N.I.C.
LONGEST COMMON
PATH: 62' N.I.C.
NO CHANGE TO BUILDING AREA
NO EXTERIOR WORK
NO CORE /SHELL WORK
NO STRUCTURAL WORK
OCCUPANT LOAD CALCULATION
TOTAL SUITE SQUARE FOOTAGE:
(X) OCCUPANCY LOAD FACTOR:
TOTAL:
(1) EXIT REQUIRED; (1) EXIT PROVIDED
2,598
I 100
= 26 OCCUPANTS
2 I KEY PLAN, EXITING AND OCCUPANCY LOAD CA
SECOND FLOOR PLAN
1/16" =1' -0"
0 5' 10' 20' 30'
NORTH
I Ytl Ytl Immi
LCULATION
PROVIDE, PER PLAN, 4' -0" WIDE
ACOUSTICAL CEILING TILES
CENTERED OVER PARTITION
ABOVE HUNG CEILING AT
DEMISING WALLS.
REVEAL (PAINT BLACK) OR MATCH
EXISTING CONDITION.
118" BLACK FOAM TAPE HOLD BACK
1/4" FROM EDGE OF TRACK
PROVIDE ACOUSTIC BATT
INSULATION BETWEEN STUDS
AT DEMISING WALLS.
1<111iMill iMIUSSf
'sum al! �msno a1a
A
SEISMIC BRACING PER 6/TI -1.
1/4" NON -COMB. WD FILLER
UNDER MAIN RUNNERS
CONTINUOUS CEILING GRID -
DO NOT CUT.
LINE OF CEILING GRID BEYOND, SEE
R.C.P.
CONT. 'L' METAL TRIM W/ PAPER WING
CONT. 2 1/2" x 1 1/4" 25 GA. TRACK W/
(2) #10 SCREWS @ 24" O.C.
6" X 18 GA. METAL PLATE BLOCKING
@ WALL HUNG ITEMS
HEAD SECTION
2 1/2" x 25 GA. GALV. STEEL STUD @
24" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE.
PLAN VIEW
5/8" GWB, TYPE 'X' EACH SIDE, TYP.
BASE, AS SCHEDULED.
- CONT. 25 GA. GALV. STEEL RUNNER
CHANNEL - ANCHOR TO FLOOR AS
101 REQ'D. HILTI POWER DRIVEN
FASTENER 3/4" MIN. EMBEDMENT.
BASE SECTION
STANDARD PARTITION
12
MINKLER BLVD.
ANDOVER PARK W.
BLDG 3
hrY
IISTRANDER
Q BLVD.
SOU THCEN
r
O
MINK
UPLAND R.
MIDLAND DR.
TRILAND DR.
ER
S
BLVD.
TE
SEPARATE Pi: ,:oiT
REQUIRED
Bt'
erMechan cc
1
3 I SITE PLAN
NA
4 I VICINITY MAP
NA
EXISTING VERTICAL
OR HORIZONTAL
STRUCTURE
METAL CLIP
METAL STUDS STAGGERED @ 8' -0"
O.C. FOR ALL UNBRACED STRAIGHT
RUNS OF WALL OVER 12' -0 ". ATTACH
TO STRUCTURE ABOVE W/ HILTI
POWER DRIVEN FASTENER 3/4" MIN.
(2) #10 SCREWS
SCHEDULED CEILING TILE & GRID
8' MAX 8' MAX 8' MAX 8' MAX 8' MAX
I
OMIT BRACING AT WALL
LATERAL BRACING (STAGGERED) PER
DETAIL ABOVE (TYP.)
LATERAL WALL BRACING PLAN VIEW
NTS
8' MAX . 2' MAX
);)'TO END
I II OF WALL
TOP OF WALL
NOTES:
1. LATERAL BRACING IS TO BE INSTALLED ON
TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT
INTERSECTIONS WITH WALLS AT LEAST 4 FEET
LONG. (PER TYPICAL PARTITION PLAN)
2. PROVIDE BRACING AT ANY PERMANENT
PARTITION THAT IS NOT ATTACHED TO CEILING
GRID.
NA 6 I PARTITION HEAD BRACING DETAIL
+
n
+
+
21/2" X 25 GA. STL. STUDS
5/8" GWB, TYPE 'X', TYP.
STEEL TUBE BRACING -
SEE ISOMETRIC BELOW
PLAN
9 "X31/2 "X21/4 "X3/16"
METAL 1.' EACH SIDE SECURED
TO STEEL TUBE & ANCHORED
TO FLOOR AS REQUIRED
NOTE:
STEEL TUBE SUPPORT TO BE
MAX. HEIGHT FOR PARTITION
NA 7 I PARTIAL HEIGHT PARTITION
ISOMETRIC
SCOPE OF WORK
TENANT IMPROVEMENT TO PART OF THE SECOND FLOOR FOR OFFICE USE TO INCLUDE DEMOLITION OF PARTITIONS
AND CONSTRUCTION OF NEW PARTITIONS, DOORS, RELITES, CASEWORK AND OTHER FEATURES.
AREA OF SUITE: 2,598 SQ.FT.
OCCUPANCY TYPE: B
CONSTRUCTION TYPE: VN SPRINKLERED
BUILDING CODES:
2006 INTERNATIONAL BUILDING CODE (IBC)
2006 INTERNATIONAL FIRE CODE (IFC)
2006 UNIFORM PLUMBING CODE (UPC)
2006 INTERNATIONAL MECHANICAL CODE (IMC)
2008 NATIONAL ELECTRICAL CODE
ICC /ANSI 117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11
WASHINGTON INDOOR AIR QUALITY CODE
ASSESSOR'S PARCEL #: 262304 -9143
LEGAL DESCRIPTION
All that certain real property situated in the City of Tukwila, County of King State of Washington, being a portion of the east 1/2 of the northwest
1/4 of the southeast 1/4 of Sec. 26, T.23N, R.4E, W.M., and being more particularly described as follows: BEGINNING at the intersection of the
northerly line of said southeast 1/4 with the westerly margin of Andover Park West (59th Avenue South), distant along said northerly line
N88 °05'42 "W 1369.34 feet from the northwest comer of said south- east quarter; thence from said POINT OF BEGINNING alond said westerly
margin 501 °47'29 "W 451.30 feet; thence leaving said westerly margin tangent to the preceding course along the arc of a curve to the right having
a radius of 50.00 feet and a central angle of 90 °06'49 ", an arc length of 78.64 feet to a point on a line that is parallel to and 501.40 southerly of the
northerly line of said southeast 1/4; thence along said parallel line N88 °05'42 "W 180.90 feet to a point on a line that is parallel with and 261.00
feet westerly of the east line if said east 1/2; thence along last said parallel line N01 °47'29 "E 136.00 feet to a point on a line that is parallel to and
365.40 feet southerly of the northerly line of said southeast 1/4; thence along last said parallel line S88 °05'42 "E 37.50 feet to a point on a line that
is parallel to and 223.50 feet westerly of the east line of said east 1/2; thence along last said parallel line N01 °47'29 "E 100.00 feet to a point on a
line that is parallel to and 265.40 feet southerly of the northerly line of said southeast 1/4; thence along last said parallel line N88 °05'42 "W 12.50
feet to a point on a line that is parallel to and 236.00 feet westerly of the east line of said east 1/2; thence along last said parallel line N01 °47'29 "E
265.40 feet to a point on the northerly line of said southeast 1/4; thence along said northerly line S88 °05'42 "E 206.00 feet to the POINT OF
BEGINNING and containing 2.408 acres of land more or less.
ADDRESS: 575 ANDOVER PARK WEST
PROJECT DIRECTORY
TENANT
WEA RANIER UNISERV
BUILDING REPRESENTATIVE
AMERICAN MANAGEMENT SERVICES dba PINNACLE
810 THIRD AVE, SUITE 140
CONTACT: TAMARA GENZALE
TELEPHONE: (206) 903 -0662
EMAIL: tgenzale @prmc.com
DESIGNER
MARVIN STEIN AND ASSOCIATES, LLC
2221 FIFTH AVENUE
SEATTLE, WASHINGTON 98121
CONTACT: GEORGE GOODFELLOW
PHONE: (206) 441 -1449
FAX: (206) 441 -4361
EMAIL: g.goodfellow @marvinstein.com
GENERAL CONTRACTOR
TBD
FILE COPY
Permit tio., 0" O1
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
t'rtc violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:.
By sc!f\ftimr.fiNCV\ ‘k-
Date: _ 0
City Of 1111JILDING DIVISION
HVAC AND FIRE LIFE SAFETY NOTES
HVAC
1. RECONFIGURE AS REQUIRED FOR ALTERATIONS.
2. RE- BALANCE HVAC SYSTEM.
REVISIONS
No changes shall be made to the scope
3. CLEAN ALL EXISTING GRILLES. Of Work without prior approval of
Tukwila Building Division.
4. VERIFY AND RELOCATE THERMOSTAT(S) AS NECESSARY. NOTE': revisions will require a new plan submittal
tr.1 may include additional plan review fees. j
FIRE LIFE SAFETY
1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO BE PER CODE.
2. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY.
GENERAL NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL
APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED.
2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS &
SPECIFICATIONS FOR BUILDING.
3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF
ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK.
4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD DRAWN AND /OR SPECIFIED IN BUILDING
CONTRACT DOCUMENTS.
5. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CFNTFRI INF OF
ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. . RE IEWED FOR
CODE COMPLIANCE
APPROVED
MAR 31 2010
6. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTED OTHERWISE.
7. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDIM
JURISDICTIONS WHERE APPLICABLE.
8. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS.
9. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITIONS SO THAT FINISHES REMAIN FLU:
AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS.
G
PPJ
H6
10. PROVIDE LEVELLING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS,
DOORS, GLUE -DOWN CARPET, ETC, TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE.
SHEET INDEX
TI -1 COVER SHEET
TI -2 DEMOLITION PLAN
TI -3 CONSTRUCTION PLAN
TI-4 REFLECTED CEILING PLAN
TI -5 ELEVATIONS & SECTION
jfy of Tukwila
DING DIVISION
RECEIVED
MAR 12 2010
PERMIT CENTER
DlOOTh
SOUTHCENTER
CORPORATE SQUARE
BUILDING 3
575 ANDOVER PARK WEST
TU K WI LA, WA
Marvin Ste
planning
sociates, LLC
design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: LB /CL
CHECKED BY: SN /GG
JOB NO.: 99135.045
NO. REVISIONS INDICATED THUS A
DATE
BY
PERMIT SET FOR APPROVAL
PRICING /CONSTRUCTION SET
03/08/10 LB
03/11/10 CL
TENANT:
WEA
RAINIER UNISERV
SHEET TITLE:
COVER SHEET
NA
8
PROJECT INFORMATION
NA
REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS
DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS
A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT
BY MS &A 2010.
TI -1
OF 5
N
01
0
0
01
0
0
0
0
0
U
N
COO
N)
0,
C
0
0
U)
0
L.
0
U
N
a)
0
t
0
C�
N
I m
NN
U O
I
mm
.,.3�
'0U
0 q)
L L
pox
0
10
r
Li
r== =d
r
II
II
II
111
NIC
NIC
0 0 0
,WON Eft
I -,
I I
0
MEN
DEMOLITION LEGEND DEMOLITION NOTES
EXISTING BUILDING CORE AREA (N.I.C.)
EXISTING PARTITION TO REMAIN.
EXISTING CORRIDOR PARTITION TO REMAIN.
EXISTING CONSTRUCTION TO BE DEMOLISHED.
1. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT
IMPROVEMENT.
2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM
AND SECURITY SYSTEMS MUST BE COORDINATED WITH ALL
GOVERNING AGENCIES AND BUILDING OWNER / MANAGEMENT.
3. SEE TI -1 FOR GENERAL NOTES.
4. SAVE REMOVED DOORS ON -SITE FOR POSSIBLE RELOCATION.
5. REMOVE FLOORING AND BASE THROUGH -OUT.
DEMOLITION KEYNOTES
OREMOVE PORTION OF PARTITION TO ALLOW FOR INSTALLATION
OF NEW GLASS RELITE. SEE CONSTRUCTION PLAN ON TI -3.
SECOND FLOOR PLAN
1/8" =1' -0"
0 5' 10'
20'
30'
NORTH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 31 2010
City of Tukwila
ROWING DIVISION
RECEIVED
MAR 12 2010
PERMIT CENTER
SOUTHCENTER
CORPORATE SQUARE
BUILDING 3
575 ANDOVER PARK WEST
TU K WI LA, WA
Marvin Ste
planning
sociates, LLC
design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: LB /CL
CHECKED BY: SN /GG
JOB NO.: 99135.045
NO.
REVISIONS INDICATED THUS A
DATE
BY
PERMIT SET FOR APPROVAL
03/08/10
LB
PRICING /CONSTRUCTION SET
03/11 /10
CL
TENANT:
bi
WEA
RAINIER UNISERV
SHEET TITLE:
DEMOLITION
PLAN
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS
A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT
BY MS &A 2010.
TI -2
OF 5
N
0
1
0_
w
C
0
C
0
U
CT.
C
0
U
N
w
cri
COM
3-
0
Cr
0
U
L
CO
0 No
1m
CD (NI
CD
1
CO CO
.0••
sue
0co
pox
CONF. RM
12101
�— —
PTN./MUL.
OFFICE
1 209
—
PTN./MUL.
OFFICE
208
•
OFFICE
1 207 I
OFFICE
1 206 I
OFFICE
12CTI
•
E
8' -O"
CONSTRUCTION LEGEND
WORK RM
202
SERVER/TEL
1 203 I
OFFICE
1 204 I
■
I
N
F -H
EXISTING BUILDING CORE AREA (N.I.C.)
EXISTING PARTITION TO REMAIN.
EXISTING CORRIDOR PARTITION TO REMAIN.
NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 5/TI -1.
NEW B/S PARTIAL HEIGHT PARTITION AT 3'-4" AFF. SEE DETAIL 7/TI -1.
NEW B/S FULL - HEIGHT TEMPERED SAFETY GLASS RELITE (WIDTH
PER PLAN).
NEW B/S GLASS RELITE AND FRAME. TOP OF FRAME TO MATCH AND
ALIGN WITH TOP OF DOOR FRAME WITH SILL AT 38" AFF. (WIDTH PER
PLAN).
NEW BUILDING STANDARD CASEWORK.
ALIGN.
EXISTING CORRIDOR
NIC
CONSTRUCTION NOTES
1. PROVIDE MINIMUM FURRING AROUND COLUMNS, IF NOT ALREADY
EXISTING.
CONSTRUCTION KEYNOTES
NIC
e e e
WOMEN
MEN
0 0 0
J
SECOND FLOOR PLAN
1/8" =1' -0"
0 5' 10'
0 PROVIDE NEW 24" X 80" TEMPERED SAFETY GLASS INSERT IN EXISTING
DOOR.
20'
DOOR SCHEDULE
EL
30'
NORTH
O'
E
6 ", UNLESS
OTHERWISE
NOTED
DOOR NUMBER
TYPE OF DOOR
A. NEW B/S 3' -0" W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S WOOD
FRAME.
B. NEW PAIR OF B/S 3' -0 "W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S
WOOD FRAME.
C. NEW B/S 3' -0 "W X 8'-4 "H X 1 -3/4" THICK SC WOOD DOOR IN B/S WOOD
FRAME WITH 24" X 80" TEMPERED SAFETY GLASS INSERT.
HARDWARE
a. B/S LATCHSET.
b. B/S LOCKSET
c. B/S DOUBLE DOOR HARDWARE WITH LATCHSET
d. B/S LOCKSET & CLOSER.
EXISTING DOOR TO REMAIN
CODE REVIEWED
V�,lD�
APPROVED
MAR 31 2010
ofTukwila
Ri.11LDICityNG DIVISION
RECEIVED
MAR 12 2010
PERMITCENTER
SOUTHCENTER
CORPORATE SQUARE
BUILDING 3
575 ANDOVER PARK WEST
TU K WI LA, WA
Marvin Ste
planning
sociates, LLC
design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: LB /CL
CHECKED BY: SN /GG
JOB NO.:
99135.045
NO.
REVISIONS INDICATED THUS n
DATE
BY
PERMIT SET FOR APPROVAL
03/08/10
LB
PRICING /CONSTRUCTION SET
03/11/10
CL
TENANT:
WEA
RAINIER UNISERV
ttdI - 07 to
SHEET TITLE:
CONSTRUCTION
PLAN
REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS
DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS
A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT
BY MS &A 2010.
TI -3
OF 5
CO
U
w
0
0
0
0
N
CO)
La
CO
w
0
0
U)
0
0
U
L
Q)
0
a)
co
■
N
I 0
V7 N
00
-
mm
�,
'cn
U
U
ao
L L
ox
(ED
n
210
209
208
207
1 206
1 205 1
(4)
4EQ EQ.
L --
EQrELT
1 202 1
203
1 204
r ,
NIC
NIC
WOVEN
MEN
EL..
CEILING LEGEND
EXISTING CEILING GRID AND TILES TO REMAIN.
EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN.
EXISTING 2'X4' RECESSED FLUORESCENT EMERGENCY LIGHT FIXTURE,
(CONCEPTUAL ONLY -SEE GENERAL NOTE #2).
RELOCATED 2'X4' RECESSED FLUORESCENT EMERGENCY LIGHT FIXTURE,
(CONCEPTUAL ONLY -SEE GENERAL NOTE #2).
r-----1 EXISTING 2X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE
L____J RELOCATED.
V I
RELOCATED BIS 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES.
® (N)(R) EXISTING, U.N.O., BIS ILLUMINATED EXIT SIGN. (DIRECTIONAL WHERE
INDICATED) (N = NEW) (R= RELOCATED EXISTING)
i .(N) EXISTING, U.N.O., BIS LIGHT SWITCH. ( N = NEW)
SECOND FLOOR PLAN
1/8" =1' -0"
0 5' 10'
REFLECTED CEILING NOTES
1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL
CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING
MECHANICAL DUCT WORK, ELECTRICAL CONDUITS, PIPES, ETC. AT EVERY LIGHT
FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT
EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR.
THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW
LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL
ALL CONFLICTS ARE RESOLVED.
2. CONTRACTOR SHALL VERIFY EXISTING EMERGENCY PATHWAY LIGHTING AND
ADJUST AS REQUIRED. PROVIDE ONE FOOT CANDLE OF ILLUMINATION AT FLOOR
LEVEL ALONG THE EXIT PATHWAY. SUBJECT TO FIELD INSPECTION.
3. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V.
BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY
INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING
TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO
MATCH EXISTING AS REQUIRED.
5. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTING AS DEFINED IN CHAPTER 12, BOTH
UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE
PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING
AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE
GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE.
6. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN
AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS,
WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED.
7. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE
DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF
CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING
CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS,
EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN
ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE
REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED
WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN
ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING
STANDARD, USE OCCUPANCY SENSORS AS REQUIRED.
20'
REFLECTED CEILING NOTES
30'
NORTH
OREMOVE EXISTING EXIT SIGN AND RELOCATE, AS SHOWN.
LIGHTING CALCULATION
2,598 TOTAL S.F. x 1 WATT PER S.F. = 2,598 ALLOWABLE WATTS.
TOTAL PROPOSED WATTAGE IS 2,598. NO WATTAGE CHANGE
ALTERATION IS 47% WHICH IS LESS THAN THE 60% ALLOWED.
REVIEWED FOR
CODE COMPLIANCE
4pDRoVED
MAR 31 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
MAR 12 2010
PERMIT CENTER
SOUTHCENTER
CORPORATE SQUARE
BUILDING 3
575 ANDOVER PARK WEST
TU K WI LA, WA
Marvin Ste ° '1sociates, LLC
planning v design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: LB /CL
CHECKED BY: SN /GG
JOB NO.: 99135.045
NO
REVISIONS INDICATED THUS A
DATE
BY
PERMIT SET FOR APPROVAL
03/08/10
LB
PRICING /CONSTRUCTION SET
03/11/10
CL
TENANT:
WEA
RAINIER UNISERV
bi
SHEET TITLE:
REFLECTED CEILING
PLAN
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS
A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT
BY MS &A 2010.
TI-4
OF 5
GWB PARTIAL HEIGHT PARTITION
(PAINT AS SCHEDULED)
3/4" P -LAM FILL (BOTH SIDES).
B/S P -LAM CASEWORK W/ 4" TOEKICK
1"
EQ.
\� /"
OF1EN
/
/" I "
i
j
/" '
\
i '-..._
EQ.
ELEVATION
3/8" =1' -0"
EQ.
EQ.
1 1/2'
FRAMED OPENING WITH FRAME TO
MATCH B/S RELITE FRAME
FACE OF GWB
P -LAM ADJUSTABLE SHELF
GWB PARTIAL HEIGHT PARTITION
(PAINT AS SCHEDULED)
(6) EQ.
B/S P -LAM
COUNTERTOP
AND BACKSPLASH.
N
1 1/2" THICK P -LAM
FILLER
/ \ / \
/ \ /" \
sx
V=
INSULATE WRAP @
EXPOSED SUPPLY &
DRAIN LINES
N
n
i \ /
> /"
\ /
N
EQ. EQ.
EQ.
36"
EQ. EQ.
EQ.
ELEVATION
3/8" =1' -0"
GWB (PAINT AS SCHEDULED.)
CEILING
B/S FRAME TO MATCH EXISTING.
CONTRACTOR TO PROVIDE ALLOWANCE OF
$1500.00 FOR SHADE OR SIMILIAR - COORDINATE
WITH TENANT AND OWNER.
1"
B/S WALL MOUNTED METAL
SUPPORT
GWB (PAINT AS SCHEDULED.)
°
°
°
°
°
°
°
0
0
0
0
°
°
0
d
d
0
MAX.
°
0
/.
INTERIOR °
0
DIM.
0
0
0
0
0
0
0
0
0
A
B/S P -LAM COUNTERTOP WITH
SELF -EDGE.
PROVIDE BLOCKING AS REQUIRED,
TYP.
BASE, AS SCHEDULED.
N
SECTION
1 112 " =1' -0"
B/S P -LAM UPPER CABS. WITH
DOORS AND (2) ADJ. SHELVES, TYP.
FACE OF GWB
B/S A.D.A.-APPROVED P -LAM SINK
CABINET (NO BOTTOM @ BASE)
WITH B/S A.D.A.-COMPLIANT SINK &
FAUCET.
B/S P -LAM LOWER CABS. WITH
DOORS, DRAWERS, (1) ADJ. SHELF
AND 4" TOE KICK, TYP.
NOTE:
PROVIDE FINISHED ENDS AT ALL EXPOSED ENDS.
PROVIDE FILLER FOR UPPER & LOWER CABINET
AS NECESSARY
PLAN DETAIL
1 112 " =1' -0"
1"
\
= ==
/
(5) EQ.
/ N
=I =_ ==
7/'
'1U1/
//
N
= = =
/"
NY
=
ELEVATION
3/8" =1' -0"
LOW WALL BELOW
LINE OF TRANSACTION TOP.
CASEWORK BELOW
IL
i- - - --
1
i
FACE OF GWB
B/S P -LAM UPPER CABS. WITH
DOORS AND (2) ADJ. SHELVES,
TYP.
B/S P -LAM COUNTERTOP
AND BACKSPLASH.
B/S P -LAM LOWER CABS. WITH
DOORS, DRAWER, (1) ADJ. SHELF
AND 4" TOE KICK, TYP.
NOTE:
PROVIDE FINISHED ENDS AT ALL
EXPOSED ENDS.
PROVIDE FILLER FOR UPPER &
LOWER CABINET AS NECESSARY
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 31 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
MAR 12 2010
PERMITCENTER
SOUTHCENTER
CORPORATE SQUARE
BUILDING 3
575 ANDOVER PARK WEST
TU K WI LA, WA
Marvin Ste «.sociates, LLC
planning
design
2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449
DRAWN BY: LB /CL
CHECKED BY: SN /GG
JOB NO.: 99135.045
NO.
REVISIONS INDICATED THUS A
DATE
BY
PRICING /CONSTRUCTION SET
03/11 /10
CL
TENANT:
WEA
RAINIER UNISERV
0-7
SHEET TITLE:
ELEVATIONS &
SECTION
REPRODUCTION, ALTERATION OR PUBLICATION OF THIS
DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS
A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT
BY MS &A 2010.
TI -5
OF 5