Loading...
HomeMy WebLinkAboutPermit D10-098 - NORTHWEST COMPUTER SOLUTIONS - TENANT IMPROVEMENTNW COMPUTER SOLUTIONS 18300 CASCADE AV S D10-098 City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 7888900175 Permit Number: D10-098 Address: 18300 CASCADE AV TUKW Issue Date: 06/16/2010 Suite No: Permit Expires On: 12/13/2010 Tenant: Name: NW COMPUTER SOLUTIONS Address: 18300 CASCADE AV , TUKWILA WA Owner: Name: RIVERPOINT TWO LLC Address: 1100 OLIVE WY #1005 , SEATTLE WA 98101 Phone: Contact Person: Name: PAUL ENGERT Address: 130 LAKESIDE AV , SEATTLE WA 98122 Phone: 206 - 325 -2553 Contractor: Name: SMAJIC CONSTRUCTION LLC Address: 12219 SE 65TH ST , BELLEVUE WA 98006 Phone: (206)419 -8090 Contractor License No: SMAJICL954R2 Expiration Date: 12/22/2011 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT ON FIRST FLOOR. CEILING, LIGHTING & FLOOR FINISHES ARE EXISTING Value of Construction: $155,000.00 Fees Collected: $3,181.82 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -7/07 D10 -098 Printed: 06 -16 -2010 City "Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspectio n Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us Permit Number: D10-098 Issue Date: 06/16/2010 Permit Expires On: 12/13/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: (0— (HO I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe construction or the pe \ Signature: iI Print Name: r does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ce of , • am authorized to sign and obtain this development pe t. Am-A} Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -7/07 D10 -098 Printed: 06 -16 -2010 • City of Tukwila Department of Community Development n 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 7888900175 Address: Suite No: Tenant: 18300 CASCADE AV TUKW NW COMPUTER SOLUTIONS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10-098 ISSUED 04/13/2010 06/16/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D10 -098 Printed: 06 -16 -2010 City of Tukwila Department of Comnurnity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 nun) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction doc: Cond -10/06 D10 -098 Printed: 06 -16 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwi la. wa. us cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 41: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 42: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Cond -10/06 D10 -098 Printed: 06 -16 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 43: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes such condition or violation. 44: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila (206)575 -4407. * *continued on next page ** does not imply approval of Fire Prevention Bureau at doc: Cond -10/06 D10 -098 Printed: 06 -16 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p -rmit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the _ rmance of work. Signature: Print Name: Date: doc: Cond -10/06 D10 -098 Printed: 06 -16 -2010 CITY OF TUKWILI Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htV//www.ci.tukwila.wa.us • Building Permit No. bio-o qg Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 18089 00 170 Site Address: aSOO CIJSCIAM 14.W. ' ii( 7i4 Suite Number: F oor: Tenant Name: NW CO C' LU Cj Property Owners Name: d Mailing Address: 11 DO CLIV E. WitL'( , 5 q. 005 QLi - LE WA- City State New Tenant: Yes ❑ ..No Cre)I 01 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Vl.. CN&.1.T Mailing Address: IW i.r4 Day Telephone: 200 3214 25.53 WA- q'B1Z2 E -Mail Address: ?eN Te LM . CO■ Fax Number: State Zip 2do '7_49- GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: _ City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD = All plans must be wet stamped by Architect of Record Company Name: .1-4NOE MOEW 4 A 9J C.iATC-S Mailing Address: • L41 PE Contact Person: ' M AS Pao/E. W 18122 State Zip Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:'Applications\rorms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORIVO'ION - 206 -431 -3670 • Valuation of Project (contractor's bid price): $ 1 t? i 3, 000 Existing Building Valuation: $ � coo, wo Scope of Work (please provide detailed information): .11_C.t t %, '_.t ( 0,4x12.. C IU N& � Uf 11� b2 FIN is> Will there be new rack storage? ❑ Yes Er./No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 4) 4' Compact: O Handicap: 14- Will there be a change in use? ❑ Yes (Et7 No If "yes ", explain: FIRE PROTECTION/HAZARD US MATERIALS: B Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes E3/ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns- Apphcauons On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 2.1P,612 5,523 — — V -13 FS . 2nd Floor /y�� Zb, 6I2 -- -- _ V -13 F.S. , 3d Floor Floors thru • Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 4) 4' Compact: O Handicap: 14- Will there be a change in use? ❑ Yes (Et7 No If "yes ", explain: FIRE PROTECTION/HAZARD US MATERIALS: B Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes E3/ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns- Apphcauons On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 AU O D ENT: Signature: Date: 4 I3 • 0 Print Name: JL Mailing Address: 1'3O - . 7E Ave Day Telephone: 211e 325-'1%3 WA Q81z2 45154fritLy State Zip Date Application Accepted: �— 13 ` C 1 Date Application Expires: 10— --lb Staff Initials: Wi H:Wppltcattons \Forms - Applications On Lme\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: hto,://www.ci.tukwila.wa.us Parcel No.: 7888900175 Address: 18300 CASCADE AV TUKW Suite No: Applicant: NW COMPUTER SOLUTIONS RECEIPT Permit Number: D10-098 Status: APPROVED Applied Date: 04/13/2010 Issue Date: Receipt No.: R10 -01072 Initials: User ID: Payee: WER 1655 Payment Amount: $1,930.15 Payment Date: 06/16/2010 12:05 PM Balance: $0.00 ADNAN SMAJIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05125G ACCOUNT ITEM LIST: Description 1,930.15 Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,930.15 1,925.65 4.50 PAYME;T RECEIVED doc: Receiot -06 Printed: 06 -16 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 7888900175 Address: 18300 CASCADE AV TUKW Suite No: Applicant: NW COMPUTER SOLUTIONS RECEIPT Permit Number: D10-098 Status: PENDING Applied Date: 04/13/2010 Issue Date: Receipt No.: R10 -00624 Initials: User ID: Payee: WER 1655 Payment Amount: $1,251.67 Payment Date: 04/13/2010 02:33 PM Balance: $1,930.15 LANCE MUELLER & ASSOCIATES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 28561 1,251.67 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,251.67 Total: $1,251.67 A(\ E FCUFIE doc: Receiot -06 Printed: 04 -13 -2010 INSPECTION RECORD Retain a copy with permit \\(.1..., INSPECTION NO. ` _ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: p.I J Gok Z?g- Type of Inspection: F/A/A Address: /e30o InAs&ADf ,qv Date Called: Special Instructions: OJ9li3 /7 —U/ Date Wanted: a.m. Requester: Phone No: go6-y Icy -ea 10 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: r U r r Date: _? 17 $60.00 REINSPECTION FEE REQUIRED. \Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `¢- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 cA Project: i Type of Inspection: Address: / ( g3 4C) LA.Se-AJP Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 2®( -11 CI X090 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Insp-ctor: (Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4:1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ro -0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 1v� Cao M j r'�- Type of Inspection: ear . L-, 6 t'f t i`,t6 Address: to (e3 0 a G/4S cJ+J4 Date called: �� 1-,f. C a: t{ , j� j l ---- -; Special Instructions: Date Wanted: `mom„ 7-2_6 ' I o p.m. Requester: Phone No: // __ fo 1 l / 5."�0f 0 Approved per applicable codes. Corrections required prior to approval. c-- COMMENTS: In cto : ki Date:, - L ' G' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ._ s.a A...edsti1Re "� - a712 es INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /v km,-)2/7.. Type of Inspection: . ?i..S Ac itfi)fr (/L /,V Address: /p 3C3 0 .snA o Date Called: Special Instructions: . (7_ ,c e .(1N1 : r _11-0 Date Wanted: 7-2/---/L) P.m. Requester: Phone No: ..Ao6 -.1//9 -,_500 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: RAJ ,t I Ii ,pp, J, A0 4K-- \ J.c,I NI- -r v . (7_ ,c e .(1N1 : r _11-0 G. e....; k :1, 17 6:,/e..r, Inspecto Date: % _ Z - ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: eS.._a!$r 3.aiwl.N.ss " _ .Ael4w6- 4:fr-j INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prod c Type o nspectio9: Address. 1 8d2 t) J (AR -,.-c4 r Date Called: Special Instructions: Date Wanted: 12 m. Requester: E.1 - 1?—a -^60 .1-,n Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: P IP 10 J 0 3-r--- /.t> J u AT: 1 E.1 - 1?—a -^60 .1-,n 1,-b J-e r - 3 E S c '. ' I P t,E , I DI--. c P f -O y n if A Inspe DuLli Date:_ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7. { y INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 = 575 -4407 Project: ma) C c4eipt.Ser4. 5 p L-s+Baas Type of Inspection: fl ♦ c.. ,Fr Aa.1 Address: /2'362) CciscacPc 4(4 Suite #: Contact Person: Special Instrucctions: Phone No.: I " 1 improved per applicable codes. Corrections required prior to approval. COMMENTS: 4)1 r rifs Needs Shift Inspection: Sprinklers: Fire Alarm: • Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: p Date: 7/24,04p Hrs.: •p • ' n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila ;Finance Department. Call to schedule a reinspection. . Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit - a7t /677-.5- -).l'? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 9818E5. Project: N./a, ce.w„ ". se., I�..k o1 Type of Inspection: SA/ , /C/p,t_ Po 44 Address: /8,4)0 Suite #: I y/ Ca Scads 4" S. Contact Person: Special Instructions: Pgrp sits Phone No.: VI/Approved per applicable codes. EiCorrections required prior to approval. COMMENTS: L_ 5 o yr fit/ I -4.„, 41 , Needs Shift Inspection: Sprinklers: Fire Alarm: . Hood & Duct: Monitor :. Pre -Fire: ;, Pgrp sits Occupancy Type: Inspector: ,/ J Date: -717..7))0 Hrs.: . $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from th City of Tukwila Finance Department: Call.to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 • • M �� ]. •+.(•. K.ii \V,WAz mk;:Jl[<tl .,,,fA +tiA .r.])/Me3Jh'.4.1* .•WVI P.A.ve #43k.127imit`u' ' INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit .0j o- a10 _ _10 F- 137 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: A• Ai. Gipme� r4, Si, t ..44 5 . Type of Inspection: - f.,c. _0I 4,74..1 F.,,....1 , ., . Address: 18300 cascade Suite #: /y1 Contact Person: - / Special Instructions: Phone No:: ' l 1 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: " s• ! • . � e 54 G� p1, ", 0, z Hoe et s !31.2'15 go G6.... P-1(4 S %,.c911 �• �•G/� F,1 ;) 0.r." _ , . �,.t.. Eip l-ls _ 2'1. & ... _.... . . _ ..._ ... _ • !9 „ ‘ 104- - 64.E VIALS • Needs Shift Inspection_ : - Sprinklers: , ., . Fire Alarm: Hood & Duct: / Monitor: '°' Pre -Fire: .. - ' Permits: Occupancy-Type: .- - • Inspector: rtyy 5'6 Date: 7ja.p. Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ... v:�:��� � ��i. bww�, r` 5rk';- :.�wc?�.a�a.�.w�a�!cuAh:a »ac��.�ratr'ea:.v>•rz�:� J r ..>�trirop�ts.xaaa..t,�.cae�::�? : Musa: ri4^:.,' iacti :3:z.nwsi�st�q:.�,-�- r��sesrr, :.. �' i. �. 3�. a5s�a ^�4'+�,_�.tr.,�:,r:,,w.,wy: , t+: � ,',r3.r >*�:,t�-re�..^- :xr€.`''. .; A• - 1 INSPECTION NUMBER • INSPECTION 'RECORD Retain a copy with permit 4010— 09e PERMIT NUMBERS CITY OF TU. UKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: W.4J 't' ° t v (4 .564,..t.:,,„ d Type of Inspection: Ay tin) f t-4.P P �,�� Address: ) irJ av Ga ugid.. Ave. 5. Suite #: 14 l Contact Person: a 14.4 7 Special Instructions: I. :" .' i Phone No.: Appro e j per applicable codes. 1 CorrectionsIxequuir• prior to approval. COMMENTS: Sprinklers: if Hood & Duct: Monitor: _ Pre -Fire: Permits: ., '" ./...IL.,...." r) !t ia' t 4. Spey SrM1- Tire ,. . D a t#0.0-r 240 L 3�,. s.� 5'i 4 7:411,4 I/ 3 O 6� A 7 C o ry 1i � coil' � 41 Li irk &Ai AG — d pia ■ 0+r 'L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: _ Pre -Fire: Permits: ., Occupancy Type:\ -_ ,, Inspector: 'emirs • I Date:. -, /,*4(i) Hrs.: $80.00 REINSPECTI N FEE REQUIRED. ou illreceive aninvoice from ity of Tukwila Finance Department. Call to schedule a ein'pection. Word /Inspection Record Form.Doc 1/13/06 • ' T.F.D. Form F.P. 113 L . 1 PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -098 DATE: 04 -14 -10 PROJECT NAME: NW COMPUTER SOLUTIONS SITE ADDRESS: 18300 CASCADE AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1-1-40 AuL Public W rk 4V1 Fire Prevention Structural 6Nn N,1c'1' Planning Division RIF Permit Coordinator ri1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n Comments: DUE DATE: 04 -15-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -13 -10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Smajic Construction Llc UBI No. 602566567 Phone 2064198090 Status Active Address 12219 Se 65Th St License No. SMAJICL954R2 Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 12/22/2005 State Wa Expiration Date 12/22/2011 Zip 98006 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date Smajic, Adnan Partner /Member 12/22/2005 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG4819 12/15/2005 Until Cancelled $12,000.00 12/22/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 CBIC C11SG4819 12/15/2007 12/15/2010 $1,000,000.00 10/28/2009 1 CBIC C11SG4819 12/15/2005 12/15/2007 $1,000,000.00 10/09/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 06/16/2010 CASCADE AVENUE SOUTH BUILDING 1 18300 CASCADE AVE. SOUTH 7 / --mix me. t4 128'56" E G:5.35 m./cc 0 F 7 UM ;?d c±cicic1cl Ij I • Z-- -El MCC CCE117it r -- ' MSC trtcecgan xm BUILDING 2 18200 CASCADE AVE. SOUTH 11- 11111 N 1128 :50" E / 147.37' _..._ jff`�� rah 9 I L • `l�r s. Ee't� " 'cic(tj.ftl'Icl el i C F cl4lcic� �t'e ;,jaze cIr Iv�e eiplc(c'cIej c e'.e'cis� lc �c , . " 1 ! I s!c' i. I i (c ic!cic. WEST VALLEY HIGHWAY SITE PLAN 77 NO SCALE ABBREVIATIONS c tr, ti ADJ ALT AFF ALUM L ANOD. ACT BLDG. BLK'G. BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FE FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FIRE EXTINGUISHER FACTORY FINISH FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FT FTIC FURN GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FOOT /FEET FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP. THERMO TYP VAR VCT VEN VERT VWC W/ W/0 WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL VARIES VINYL COMPOSITION TILE VENEER VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD GENERAL NOTES AREA OF WORK THIS PERMIT SOUTH BLDG. FIRST FLOOR SEPARATE PERMIT REQUIRED FOR cal leaf �r="N rkirijurnbing WGas Piping City of Tukwila B1"WING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may include additional plan review fees. M VICINITY PLAN NO SCALE FILE COPY Permit No. .D 10 - ocla Plan review approval is subject to errors and omissions. / p )roval of construction documents does not authorize tt:!, violation of any adopted code or ordi : w. Receipt cr approved Field Coy d.. wit. is acknowledged: By Date•. City Of lbkwila BUILDING DIVISION 1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. D OTHERWISE. 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. 19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4" IN 10 " -0 ". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE; tenant improvement Northwest Computer Solutions Riverpoint Corporate Center South BIdg. 18300 Cascade Avenue South Tukwila WA PROJECT NOTES TAX LOT NUMBER: 7888900170 LEGAL DESCRIPTION: SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S 78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N 11d 23' 50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11° 23' 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A OF 62D 57',52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF & PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44° 29' 00" E 96.32 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET S 82° 08' 00 "E 100.00 FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M/U TO W/ MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33' 20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51° 37' 10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.14 FEET ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEET THEN N 78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE 11 OF CORPORATE PROPERTY INVESTORS BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA BOUNDARY LINE. ZONE: SITE AREA: CONSTRUCTION TYPE: BUILDING AREA: NORTH BUILDING NO. STORIES SOUTH BUILDING NO STORIES PARKING REQUIRED: PARKING PROVIDED: CODES USED: TENANT AREA: OCCUPANCY: OCCUPANT LOAD: TENANT: C / CU 6.58 ACRES V -B FIRE SPRINKLERED 53,625 2 53,625 2 278 STALLS 414 STALLS 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 WASHINGTON STATE ENERGY CODE 2006 WASHINGTON STATE BUILDING CODE 2006 PLUMBING CODE 2006 MECHANICAL CODE 2003 ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES 5,523 USEABLE SQ. FT. (FIRST FLOOR) B - OFFICE 100 SQ. FT. /OCCP. 5,523/100 = 55 OCCUPANTS NORTHWEST COMPUTER SOLUTIONS SCOPE OF WORK: INTERIOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF APPROXIMATELY 5,523 SQ. FT. THE WORK CONSISTS OF BUILDING NEW WALLS, DOORS AND OTHER ARCHITECTURAL FEATURES. THE SPACE CURRENTLY HAS A COMPETE SUSPENDED ACOUSTICAL TILE CEILING AND LIGHTING SYSTEM. A PORTION OF EXISTING LIGHT FIXTURES WILL BE RELOCATED AND SOME NEW FIXTURES WILL BE ADDED. THE SPACE WILL BE ACCESSED BY MEANS FOR AN EXISTING CORRIDOR. BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: O'KEEFE DEVELOPMENT COMPANY 1100 OLIVE WAY, SUITE 400 SEATTLE, WA 98101 T. (206) 236 -6200 F. (206) 236 -6160 CONTACT: HARPUR DAVIDSON EMAIL: harpur @okeefedevelopment.com LANCE MUELLER & ASSOCIATES 130 LAKESIDE AVE SEATTLE, WA 98122 T. (206) 325 -2553 F. (206) 328 -0554 CONTACT: PAUL ENGERT EMAIL: pengert @Imueller.com SMAJIC CONSTRUCTION, LLC 12219 SE 65th STREET BELLEVUE, WA 98006 T. (206) 419 -8090 F. (425) 378 -2593 CONTACT: ADI SMAJIC EMAIL: smajic @msn.com DEFERRED SUBMITTALS 1. PLUMBING WORK UNDER SEPARATE PERMIT 2. MECHANICAL WORK UNDER SEPARATE PERMIT 3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT INDEX OF DRAWINGS TA1.1 COVER SHEET / SITE PLAN TA2.1 1/16" OVERALL BUILDING PLANS TA2.2 1/8" FLOOR PLAN TA2.3 1/8" CEILING PLAN TA3.1 WALL SECTION / CEILING DETAILS TA3.2 DOOR SCHEDULE / INTERIOR ELEVATIONS / DETAI S 98 ICODE FOR ODE COMPLIANCE POPS A l� JUN o 9 2010 -S ZA City of Tukwila BUILDING DIVhSInN ECEBVED APR 13 2010 PERMIT CENTER 04/13/10 PERMIT SUBMITTAL 0 N 0 10 -024 job no. P.ENGERT drawn P. ENGERT checked 0 '- d O 'a ELEV. N. • EXIT IIIII1IIL 1111111111 _1111111111 DN • • VACANT 1 • /7L ®I °_21 Alm lb Al. VACANT • • Q FLOOR -2 OVERALL PLAN 77. 1/16" =11 -0" AREA OF WORK THIS PERMIT 1 1 J MEANS OF EGRESS *4s' -- 0 2yO vG ‘ y� • EXIT • 17 -0' 27-0' 27-0 27-0' 27 -0' 27-0' 27-0' 27-0' 27-0' • LEASE SPACE ELEV. MACH. LOB=NM MOMS .111111111 11.11111.1 MINIM 0.611 BY LEASE SPACE VACANT EXIT iii T 3 :11 ' ^\ 120' 120' X Y--� -j 17-- ?J` �f of ;r 011111111 ORM F - T - 27-11' 22,10' EXI 27.10' 160,0' 27.10' 27 -10' 27.11' L — mom — — — mom m — - e MINI M MI. - =NMI NMI 1 1 1 1 1 1 1 iyFLOOR -1 OVERALL PLAN 1/16" =1' -0" EXIT PLAN NOTES MAXIMUM DIAGONAL DISTANCE OF SPACE = 131' MAXIMUM TRAVEL DISTANCE ALLOWABLE = 300' PER TABLE 1016.1 2006 IBC (BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.) ACTUAL DISTANCE TO EXIT = 120' EXIT SEPARATION REQUIRED 131' / 3 = 44' (EXITS MUST BE SEPARATED BY 1/3 GREATEST DIAGONAL DISTANCE OF SPACE UNDER CONSIDERATION) EXIT SEPARATION PROVIDED = 56' OCCUPANCY: B - OFFICE OCCUPANT LOAD: 5,612SQ- FL/ 100 = 56 OCCUPANTS EGRESS WIDTH REQUIRED: .15" (56) = 8.4" INCHES EGRESS WIDTH PROVIDED: 2 (36 ") = 72.0" INCHES 2 ACCESSIBLE MEANS OF EGRESS ARE REQUIRED FROM SPACE DUE TO OCCUPANT LOAD PER TABLE 1015.1 2006 IBC REVIEWED PCE CODE COMPLIANCE APPROVED JUN 0 0 2.Q10 City of Tukwila BUILDING Dmcinr' ECEIVED APR 13 2010 PERMIT CENTER ••■ E 0 E COD ,o CO Cie E co dir CID y■■r N 2 U ^o ♦- W O 0 L 0 U U � C6 75 0 cu ca.o LL VERALL BUILDING PLANS / EXIT PLAN to CTJ • 1 5 sheet TA2.1 04/13/10 , a> PERMIT SUBMITTAL 0 a) 0 10 -024 job no. P. ENGERT drawn P. ENGERT checked a CO V O N -0 ••■ E 0 E COD ,o CO Cie E co dir CID y■■r N 2 U ^o ♦- W O 0 L 0 U U � C6 75 0 cu ca.o LL VERALL BUILDING PLANS / EXIT PLAN to CTJ • 1 5 sheet TA2.1 ARCHITECTURAL SYMBOLS & LEGEND EXISTING WALL TO REMAIN NEW WALL PER PLAN NEW WALL W/ SOUND INSULATION PER PLAN NEW PARTIAL HEIGHT WALL ELEVATION LETTER ELEVATION NUMBER INTERIOR ELEVATION SYMBOL SHEET NUMBER DOOR NUMBER ROOM NAME & NUMBER WALL TYPE REFERENCE OFC. (105) DETAIL NUMBER DETAIL REFERENCE SHEET NUMBER FEC 0 COLUMNS OR GRID LINES DETAIL NUMBER SECTION REFERENCE SHEET NUMBER SEMI - RECESSED FIRE EXTINGUISHER CABINET MATERIAL LEGEND II 111 -111 iii�lli!!! NW= EARTH GRAVEUROCK CONCRETE ASPHALT PAVING WOOD FRAMING BLOCKING OR SHIM FINISH WOOD GLASS(ELEVATION) GLASS(SECTION) GYPSUM WALL BOARD CAULKING /SEALANT PLYWOOD BRICK ACOUSTIC TILE RIGID INSULATION BATT INSULATION METAL ELECTRICAL SYMBOLS & LEGEND ELECTRICAL OUTLETS, LIGHTING AND SWITCHING SHOWN FOR GENERAL DESIGN INTENT. ELECTRICAL CONTRACTOR TO CONFIRM ELECTRICAL REQUIREMENTS WITH TENANT PRIOR TO ANY WORK. 1 A TIMER FOURPLEX ELECTRICAL OUTLET 110V DUPLEX ELECTRICAL OUTLET 110V DEDICATED FOURPLEX ELECTRICAL OUTLET 110V DEDICATED DUPLEX ELECTRICAL OUTLET 110V TELEPHONE /DATA OUTLET ELECTRICAL OUTLET W/ TIMER FLUSH FLOOR ELEC. 1 DATA BOX ELECTRICAL JUNCTION BOX SYSTEM FURNITURE POWER POLE LOCATION (CONFIRM W/ FURNITURE VENDOR) SYSTEM FURNITURE BASE POWER FEED (CONFIRM W/ FURNITURE VENDOR) 0 co FLOOR PLAN KEYNOTES 1. 4' x 8' x 3/4" PLYWOOD TELEPHONE BOARD - PAINT WALL COLOR. 2. 30 AMP NEMA L -30 -5R OUTLET 3. INSTALL CEILING MOUNTED EXHAUST FAN INSIDE NETWORK CLOSET. 4. INSTALL %" PLYWOOD BACKING FOR TENANT FURNISHED WALL MOUNTED TV. COORDINATE SIZE AND FINAL LOCATION WITH TENANT. 5. WRAP EXIST. TUBE STEEL COLUMN WITH %" GWB. 6 FURNITURE IS SHOWN AS A PLANNING SUGGESTION ONLY AND IS THE RESPONSIBILITY OF THE TENANT AND HIS FURNITURE VENDOR FOR COORDINATION WITH ELECTRICAL CONTRACTOR FOR PLACEMENT OF ELECTRICAL AND DATA OUTLETS. LEASE SPACE ELEV. MACH. J OFC. (116) r--� L_J /A\ LJ • OFC. I'�`Q I I I i I I I I- - - -I I r"--Ti I 1 I (.....4 1 1 L J OFC. (118) L J I 0 OFC. J Ii'J I I V iv IL ' IL OPEN OFC. (120) r- Ic 1 I I 1 \J \J \ \. T J I III 1 L - - -i- J J I - i - - - 1 II I I I II 1 r -_ -- --- 1— --1 - -- �— I ;; I 1 kr —1— r" r —r— r i L T--I- 1 �I\�I\�I\�I\�1 \�I\�I 1,�1��1 // L .I I , J J J _� L. b_ L_ OPEN OFC. (110) 1 L BREAK NETWORK LEASE SPACE (150) HALL (170) 14' -3" HALL (111) I T - -�- I 1 I OFC. � - -- L - -� -- _ j (107) IL I: C3 K ; I 11 /1 1 /1 1 /1 1 X f9 i -jL V V I//_IVJL ^ -T 1 J GIFT STORAGE (108) 11 1" 13' -0" HALL (106) H.R. OFC. (105) L J \ FC RECORD STORAGE (104) 5' -6" 10' -6" 7– SERVICE AREA (127) Zo 22' -11" 22' -10" FILE STORAGE (126 BREAK f CONF. I (102) JLU (-DOC) F-DC) MAIL COPY (103) HALL C (165) CO ,Qcp CF- Q ELEV. LOBBY JAN. / ELEC. 0 x n 111111 MMINNHH 14'- RECEPT. (101) 25' -6" �— 11 (- — T = 1 = T ` = x = = SALES SALES (118) II 00 , — 1-- -i1- - -1- -I .= .1- - =iL == = _� —,— OFC. 67 =_ -s_-_- _ 107 HALL T SHIPPING OFC. (124) 19' -11Y2" 22' -10" 12' -1" OFC. v� 11, -10" 22' -10" 160' -0" j` j pp��I 1 OPEN OFC. (116) - - -d OPEN OFC. EXEC. OFC. (107) OFC. OFC. Q)► n•► 40' -1" 22' -10" C 12' -1" 12'-4" 22' -10" 22' -11" 0 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 092010 City of Tukwila BUILDING DIVISIMI RECEIVED APR 13 2010 PERMIT CENTER (� FLOOR -1_ FLOOR PLAN 1)10 / 118" = 1' -0,' 04/13/10 AIT SUBMITTAL 0 "v0 0 0 3ERT P. ENGERT checked 0 M d- o 0 -0 CEILING / LIGHTING SYMBOLS EB EXIT EXIT $3 6" DIA. RECESSED COMPACT FLUORESCENT WALLWASHER LIGHT FIXTURE - 32W 6" DIA. RECESSED COMPACT FLUORESCENT LIGHT FIXTURE - 32W (EB = EMERGENCY EGRESS LIGHT FIXTURE W/ 90 MIN. BATTERY BACKUP) LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) DIRECTIONAL LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) LIGHT SWITCH W/ DIMMER LIGHT SWITCH THREE -WAY LIGHT SWITCH Zo CEILING/ LIGHTING SYMBOLS EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE CEILING AND GRID SYSTEM TO REMAIN NEW Z X 4' SUSPENDED ACOUSTICAL TILE CEILING AND GRID SYSTEM (MATCH EXIST SYSTEM) EXISTING GWB CEILING TO REMAIN NEW GWB CEILING TO REMAIN EXISTING 2' x 4' BLDG. STD FLUORESCENT LIGHT !L4 - _ �' FIXTURE TO REMOVED OR RELOCATED EXISTING 2' x 4' BLDG. STD FLUORESCENT LIGHT FIXTURE TO REMAIN NEW OR RELOCATED 2' x 4' BLDG. STD FLUORESCENT LIGHT FIXTURE (EB = EMERGENCY EGRESS LIGHT FIXTURE W/ 90 MIN. BATTERY BACKUP) GENERAL NOTES ELECTRICAL CONTRACTOR SHALL INSTALL EMERGENCY EGRESS LIGHTING WITHIN TENANT SPACE TO PROVIDE A MINIMUM OF 1 FOOTCANDLE AT THE WALKING SURFACE. THIS IS IN ACCORDANCE WITH 2006 IBC SECTION 1006. ELECTRICAL CONTRACTOR SHALL MEASURE LIGHTING LEVELS ALONG THE COMMON PATH OF EGRESS TO MAINTAIN THE 1 FOOTCANDLE MINIMUM LEVEL TO THE EXIT DISCHARGE. THE EMERGENCY LIGHTING SHALL BE INSTALLED ALONG THE "COMMON PATH OF TRAVEL" SEE SHEET TA2.1 FOR LOCATION 2. SUSPENDED CEILING SYSTEM IS EXISTING THROUGHOUT THE SPACE. SEE SHEET TA3.1 FOR NOTES REGARDING ANY CHANGES OR ALTERATIONS TO SYSTEM. 3. EXISTING COMMON HALL IS A NON -RATED HALLWAY. 4. REPLACE ANY STAINED OR DAMAGED SUSPENDED TILES WITH NEW TO MATCH EXISTING. 5. PROPOSED LIGHTING WATTAGE LEVELS ARE LESS THAN WHAT CURRENTLY EXISTING WITHIN THE SPACE PROPOSED FOR REMODEL. _EASE SPACE WOMEN ELEV. MACH. N ELEV. large um aim INN minrii III _ ,./11111•111=■• RE EP 101 BREAK (121) :;: Vii■ ` ■ ■_II , ■1 ■ ,a■■ 106 i■■ 1111111111111111111MHI 1 11111 11111 LJ ■ C7 inotamill 111111111 11111111111 111 0 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 9 2010 27-11" 22' -10" 22' -10" 22' -10" 160' -0" 22' -10" 22' -10" 27-11" City of Tukwila BUILDING DlviSinm RECEIVED APR 13 2010 PEA' `n ITCENTER FLOOR -1 CEILING PLAN 1/8" = 1'-0" 1)10-%- Cn CC lbw CID E cp O CD g '4"ict aim 0 CCI 0 N 0 0 � Cn CD cp Q� O 43 c.:?, 0 U � > CO co LL 0 u) z J V z W U 0 0 th N m N F- N W 5 I• sheet TA2.3 Co v M : O [B PERMIT SUBMITTAL C 0 .en o 0 10 -024 job no. P. ENGERT drawn P. ENGERT checked 0 M C5 a) -o Cn CC lbw CID E cp O CD g '4"ict aim 0 CCI 0 N 0 0 � Cn CD cp Q� O 43 c.:?, 0 U � > CO co LL 0 u) z J V z W U 0 0 th N m N F- N W 5 I• sheet TA2.3 IF HANGER WIRE IS OUT OF PLUMB GREATER THAN 1:6 COUNTER SPLAY PER ASTM C636 WALL WHICH PENETRATES CEILING GRID WALL EDGE MOLDING 1 MAX. 8" #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE @ EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY 1 0 0 0 _ MIN.2" MIN. 3/4" @ UN- ATTACHED WALLS EDGE BRACING CEILING SEISMIC BRACING TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID #12 HANGER WIRE – ANCHORED TO STRUCTURE ABOVE SEISMIC JOINT CLIP EXPANSION SLEEVE CEILING EXPANSION JOINT STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY CROSS TEE PER ASTM C635 EDGE BRACING ISOMETRIC STEEL STUD COMPRESSION POST ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION #12 HANGER WIRE TYP. TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) CROSS TEE PER ASTM C635 MAIN CEILING BEAM PER ASTM C635 CEILING GRID SEISMIC BRACING NO SCALE SUSPENDED CEILING ARE TO COMPLY WITH THE FOLLOWING CODES AND REGULATIONS: A. 2006 INTERNATIONAL BUILDING CODE (IBC) SECTION 803.9 B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C635 AND ASTM C636 (REFERENCED IN IN 803.9). C. ASCE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 7 SECTION 9.6.2.6 D. CISCA (CEILING & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) RECOMMENDATIONS FOR SEISMIC ZONES 3-4 REFERENCED IN ASCE - 7 SECTION 9.6.2.6.2.2 E. IBC 102.1 STATES "WHERE IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, = METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE ". F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: • ONLY A HEAVY DUTY T -BAR GRID SYSTEM SHALL BE USED. ASTM - 7 SECTION 9.6.2.6.2.ITEM A. • WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE ) SHALL BE NOT LESS THAN 2 INCHES. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM B. • ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A3/4" INCH CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASTM -7 SECTION 9.6.2.6.2.2 ITEM B. • STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND OR CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR ALL EDGES . CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • VERTICAL HANGERS SHALL BE NO. 12 GAGE WIRE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE WIRE SPACED AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED WITHIN 1:6 OUT -OF- PLUMB UNLESS COUNTER - SLOPING WIRES ARE PROVIDED. • LATERAL BRACING IS REQUIRED. SPLAY WIRES PODS AT 12" MAX. O.C. AND 6' -0" MAX. FROM WALLS. INSTALL TRULY COMPRESSIBLE (E.G. SPRING LOADED) STRUTS OR NO STRUTS AT ALL. RIGID STRUTS ARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONE MAY 2004, INSTALLATION SECTION, ITEM 3 AND CITY C)P'� 14h, • CEILINGS OVER 2500 SQ . FT. MUST HAVE S_EISMIC 4FPARATinN. inin�rc _ R FULL EEIGHT WALLS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQ. FT. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM D. • FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OF ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF A LEAST 1 INCH IN ALL DIRECTIONS; OR SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM E. • CHANGES IN CEILING PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM F. • CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUSPENDED INDEPENDENTLY FROM THE CEILING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM G. ATTACH 2 2" x 20 GA. METAL STUDS BRACES TO TOP TRACK W/ (2) - METAL FRAMING SCREWS 22" x 20 GA. METAL STUDS BRACES @ 8' -0" O.C. (ALTERNATE DIRECTIONS) AT ALL WALL LOCATIONS OVER 12' -0" LONG. ATTACHED TO WOOD FLOOR STRUCTURE ABOVE TYP. OFFICE PARTITION ATTACHMENT OF CEILING GRID ACOUSTICAL TILE ND INSULATION PER LAN A. METAL STUDS @ ITH %" TYPE "X" GWB E NG SCREWS @ 16" O.C. R BASE NC. FLOOR SLAB 1/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPIRMED JUN 0 0 2010 City of Tukwila BUILDING nnnminM RECEIVED APR 13 2010 PE IT CENTER 4 MAKE N( 0 M O WALL TC SYSTEM PERMIT SUBMITTAL 4 EXIST. P 0 10 -024 job no. CEILING P. ENGERT checked 04/13/10 date . 22" SOU FLOOR P 21/2"X251 to 24" O.C. i• EACH SI[ 1" FRAMI i• ti TYP. 4" RUBE[ PO •. EXIST. CI 6 TYP. OFFICE PARTITION ATTACHMENT OF CEILING GRID ACOUSTICAL TILE ND INSULATION PER LAN A. METAL STUDS @ ITH %" TYPE "X" GWB E NG SCREWS @ 16" O.C. R BASE NC. FLOOR SLAB 1/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPIRMED JUN 0 0 2010 City of Tukwila BUILDING nnnminM RECEIVED APR 13 2010 PE IT CENTER W W W F- Za emo 01 O -5 • m - CID o ihml *r V) =■ s_. E- 1- (1) c a" a E4.111 o Q so > y go 2-� o o M U cwn co .,� ,fir -o U cu c — �O — c CO > M 5C CO (0 W i- < � U 0 N W J J W ' W U Z J ■ N • co 1- 5 • O sheet TA3.1 0 M O PERMIT SUBMITTAL 0 0 10 -024 job no. P. ENGERT drawn P. ENGERT checked 04/13/10 date W W W F- Za emo 01 O -5 • m - CID o ihml *r V) =■ s_. E- 1- (1) c a" a E4.111 o Q so > y go 2-� o o M U cwn co .,� ,fir -o U cu c — �O — c CO > M 5C CO (0 W i- < � U 0 N W J J W ' W U Z J ■ N • co 1- 5 • O sheet TA3.1 13 5/8" PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. GOOSE NECK FAUCET S.S. SINK OPEN CABINET FOR HC ACCESS C-) CASEWORK SECTION 1" =1' -0" 1/4" TEMPERED SAFETY GLAZING 4y2" 1 INSTALL TEMPERATURE SHIELDING ON ALL EXPOSED PIPES CENTER SET 4 1/2" CLEAR ANOD. ALUM. STOREFRONT SYSTEM EXIST. CONC. FLOOR 11 STOREFRONT SILL DETAIL 3" =1' -0" 5/8" G.W.B. EA. SIDE ON 2%" METAL STUDS 3 SILENCERS at STRIKE SIDE 1 %" HDWD. TRIM (MATCH BLDG. STD.) 1 3/4" HDWD. VENEER SOLID CORE WOOD DOOR BLDG. STD. WOOD DOOR JAMB 3 =1' -0" MICROWAVE BY TENANT PLASTIC LAMINATE MICROWAVE SHELF 35/8 "X20GA METAL STUDS BRACING @ 48" PLASTIC LAMINATE BACKSPLASH & COUNTERTOP DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE CASEWORK SECTION 1" =1' -0" BASE PER SCHEDULE 3 5/8" GA METAL STUDS @ 24" O.C. EXTEND TO ROOF STRUCT. ABOVE. %" GWB 6" x 18 GA BOX HEADER 0 w SUSPENDED CEILING SYSTEM (EXISTING) METAL 'J' TRIM AT GWB EDGE y4 TEMPERED SAFETY GLAZING STOREFRONT HEAD DETAIL 3 =1' -0" y4" TEMPERED GLASS HARDWOOD GLASS STOPS 1Y2'' HDWD. TRIM (MATCH BLDG. STD.) BLDG. STD. WOOD RELITE JAM B 3" =1' -0" WEST BREAK ROOM #121 1 /4" =1' -0" CASEWORK KEYNOTES NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE CABINETS NOTE 2. - 12" DEEP UPPER PLASTIC LAMINATE CABINETS NOTE 3. - PLASTIC LAMINATE COUNTERTOP AND BACK SPLASH NOTE 4. - ACCESSIBLE SINK (NO BASE FOR WHEELCHAIR ACCESS) NOTE 5. - MICROWAVE SHELF MICROWAVE (BY TENANT) NOTE 6. - REFRIGERATOR (BY TENANT) ALL APPLIANCES TO BE FURNISHED AND INSTALLED BY TENANT WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ VERT. MULLION 3" =1' -0" DOOR SCHEDULE DOOR NO T P E DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS MAT. FIN. MAT. FIN. PERMIT SUBMITTAL c 0 ,N 101 EX. 3' -0" x 8 -0" WOOD BLDG. STD. H.M. PAINT EX P. ENGERT checked EXIST. DOOR AND FRAME 102 A 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 3 - 103A A 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 103B D 4' -0" x 4' -0" - WOOD BLDG. STD. - RELITE 104 E SEE ELEVATION ALUM. ANOD. CLR. ALUM. ANOD. CLR 4 -- 106 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 107 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 110 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 111 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 113A B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 3 113B D 4' -0" x 4' -0" - WOOD BLDG. STD. -' - RELITE 114 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 3 -° 118 EX. 3' -0" x 8 -0" WOOD BLDG. STD. H.M. PAINT EX "' EXIST. DOOR AND FRAME 121 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 123 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 -- 124 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 125A A 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 125B C 3' -0" X 8' -0" WOOD BLDG. STD. WOOD BLDG. STD. 3 126 A 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 1 HARDWARE GROUPS 1. LEVER LATCH SET HINGES SILENCERS WALL STOP 2. LEVER LOCK SET HINGES CLOSER DOOR / RELITE TYPES 3' -0" 3. LEVER LOCK SET HINGES SILENCERS WALL STOP 3. STANDARD PUSH /PULL HINGES CONCEALED OVERHEAD CLOSER WALL STOP WOOD DOOR & FRAME (MATCH EXISTING SPECIES AND FINISH) 3' -0" �8" t 1' -6" I; 17 TA3. SOLID CORE WOOD DOOR (MATCH EXISTING SPECIES AND FINISH) WOOD FRAME (MATCH EXISTING SPECIES AND FINISH) 1/4" TEMPERED GLASS SIDELITE 3' -0" SOLID CORE 20 MIN. --- RATED DOOR & HOLLOW METAL FRAME WOOD DOOR & WOOD 1/4" TEMPERED GLASS WOOD FRAME (MATCH EXISTING SPECIES AND FINISH) WOOD DOOR FRAME W /51 WOOD DOOR & WOOD FRAME W/ SIDELITE 19' -0" HALL WOOD DOOR & HOLLOW METAL FRAME " 3' -0y4" 2' -11%" 2' -11Y4" 2" 2' -11%" 2" 3'04" 11,2" 3' -0" 2 • 2" x 4 1/2" ALUM. STOREFRONT SYSTEM CLEAR ANOD. FINISH MEDIUM STILE ALUM. DOOR W/ TEMPERED GLASS 1/4" LAMINATED & TEMPERED GLASS (b) WOOD FRAME RELITE 'A• WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT 19 2" .050 ALUM. BREAK SHAPE TO MATCH EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @FALSE MULLION ALUMINUM STOREFRONT WINDOW WALL 3" =1' -0" WALL CONSTRUCTION PER FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 9 2010 City of Tukwila UILDING nil/ Inn! EQEBV APR 13 2E] PERMIT CENTEF SEMI- RECESSED FIRE CABINET SEMI- RECESSED FIRE EXTINGUISHER CABINET 3 =1' -0" w w w N w c CID E CD N E CM O CD E c mom O) 0 CO 0 CJ) DOOR SCHEDULE CO Ln N Ln CO N • (1 sheet TA3.2 0 c...,...5 c PERMIT SUBMITTAL c 0 ,N 0 10 -024 job no. P. ENGERT drawn P. ENGERT checked 0 M d m o -o w w w N w c CID E CD N E CM O CD E c mom O) 0 CO 0 CJ) DOOR SCHEDULE CO Ln N Ln CO N • (1 sheet TA3.2