HomeMy WebLinkAboutPermit D10-100 - POINT TO POINT TRANSPORTATION - STORAGE RACKSPOINT TO POINT
TRANSPORTATION
12610 INTERURBAN AV S
D10 -100
Cityef Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /wwwci.tukwila.wa.us
DEVELOPMENT PERMIT
Parcel No.: 0004800003
Address: 12610 INTERURBAN AV S TUKW
Suite No:
Permit Number: D10 -100
Issue Date: 05/13/2010
Permit Expires On: 11/09/2010
Tenant:
Name: POINT TO POINT TRANSPORTATION
Address: 12610 INTERURBAN AV S , TUKWILA WA
Owner:
Name: C/O EPROPERTYTAX INC
Address: DEPT #207 , PO BOX 4900 85261
Phone:
Contact Person:
Name: RICH FISHER
Address: 23310 61 AV S #BB -101 , KENT WA 98032
Phone: 206 - 406 -9556
Contractor:
Name: DACO CORPORATION
Address: 18715 E VALLEY HY , KENT, WA 98032
Phone: 425 - 656 -4505
Contractor License No: DACOC * *012NC
Expiration Date: 05/01/2012
DESCRIPTION OF WORK:
PROVIDE AND INSTALL ONE (1) SINGLE ROW OF SELECTIVE PALLET RACK, EIGHT (8) BAYS LONG
Value of Construction: $0.00 Fees Collected: $433.01
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006
Type of Construction: V -B Occupancy per IBC: 0025
* *continued on next page **
doc: IBC -10/06
D10 -100 Printed: 05 -13 -2010
City oilTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: D10 -100
Issue Date: 05/13/2010
Permit Expires On: 11/09/2010
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
OA '1g,
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th erform nc of work. I am authorized to sign and obtain this development permit.
Signature: Date: /g//45
Print Name:( G r , s�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC -10/06
D10 -100 Printed: 05 -13 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 0004800003
Address:
Suite No:
Tenant:
12610 INTERURBAN AV S TUKW
POINT TO POINT TRANSPORTATION
Permit Number:
Status:
Applied Date:
Issue Date:
D10 -100
ISSUED
04/15/2010
05/13/2010
1: ** *BUILDING DEPARTMENT CONDTITONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications.
5: When special inspection is required, either the owner or the registered design professional in responsible charge,
shall employ a special inspection agency and notify the Building Official of the appointment prior to the first
building inspection. The special inspector shall furnish inspection reports to the Building Official m a timely manner.
6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections
shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special
inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection
approval.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet
in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and
calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State
of Washington.
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
* *continued on next page **
doc: Cond -10/06
D10 -100 Printed: 05 -13 -2010
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
E'L co- - c. c4- Z
Date: S'---// 37/ a
doc: Cond -10106
D10 -100 Printed: 05 -13 -2010
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No. 1)10 -
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
00
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.:
0 LE DD— CCO3
Site Address: /c)-(, /0 -"J7 e2 Ufei -Ar..)AVE S Suite Number: Floor:
Tenant Name: F V r tir y- i O r O S (,y3 New Tenant: ❑ Yes g14. No
Property Owners Name:
Mailing Address:
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Gtr 64€ rL
Mailing Address: 1 l O 67I " QV C • _JOE -' 1O 1
E -Mail Address: Et. C.44. OC c've tr- • CC N +.
Day Telephone: o7Oto -4/06 -.S-.S""":„
/� r'e'v.' (,vA 61
City State Zip
Fax Number: o S 3 X77=7X -
GENERAL CONTRACTOR INFORMATION; —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: /-
Mailing Address: 1 7 t S g . VA . C-- -1- rr /-1 e C! /� �" �k r"G" 14. .)4 �' C7 '� w
�� -.-.1-' City State Zip
Contact Person: �`t C.(,.t Ir--'4E (G. Day Telephone: ...20 6 - 906 -`"t 5`'
E -Mail Address: t C.A. '�- b4CO C C,C P. C15 Fax Number: 0 - ( ' 7 - a:) '
taco (c, .Pc,j A cqr�
Contractor Registration Number: DP4 C0C..' O l c9- NC..-
Expiration Date: 66--7/0 i /3' c 0
ARCHITECT OF RECORD
All plans must be wet stamped by Archite
of Record
Company Name:
Ail 4-
Mailing Address:
City
Day Telephone:
Fax, Number:
Contact Person:
E -Mail Address:
State
Zip
ENGINEER OF RECORD - All plats must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person: CT Act et � 0044 .1
E -Mail Address: en 0/ZLt 1 J �4 o'C . (c'
4-1 /a. ( A c s . 2 / V D a b c , u r , a/ G Lzs'b t. E
H: VApplicationsWorms- Applications On Line\2009 Applications \1 -2009 • Permit Application.doc
Revised: 1 -2009
bh
City
Day Telephone: I S— „lc/0 -- 3 g t 0
Fax Number: 5. t g —0!-/Z5 — ?$ t 3
State
Zip
Page 1 of 6
BUILDING PERMIT INFORIV LION - 206 - 431 -3670
Valuation of Project (contractor's bid price): $ `gj r Existing Building Valuation: $ �lh
Scope of Work (please provide detailed information): P /LOV i be) AND //VS-r-4 -L c. Ne- Q ") Ti/VGc.G
RelA-3 5 - RJ'PP -c. . g E Acts 6. 6.,
Will there be new rack storage? .....Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: I landicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
151 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes NI No
If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
' Occupancy per
IBC
1St Floor
42141/2(.7( .
L() Si"
4I2(4 cA.m-ii
'l ' C.�.!'
1/..)t t c
2/6U sa c
2nd Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: I landicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
151 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes NI No
If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Wpplications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
•
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW R OR AUTHORIZED AGENT:
Signature:
Print Name: e1 Gb4 CIS 6. 2
Mailing Address: ,:233I O 6 /' 4- L) S G313 -/D
Date:
eifizik
Day Telephone: c2O6
City
State Zip
Date Application Accepted:
4 -(s -(6
Date Application Expires:
16-I,S' -(0
Staff Initials:
H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: 4/4-
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contracto ' . bid price): $
Scope of Work (please provide de::iled information):
Building Use (per Int'I Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: �+
Sewer:
Indicate type of plumbing fixtures and /or gas piping out `- being i tp ailed and the quantity below:
Fixture Type:.
Qty
Fixture Type:_
ty
' Fixture Type: - -
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head) ,
I�
\
Food -waste grinder,
ommercial
Floor Drain
Shower, single head trap
Lavatory � '
,t ash fountain
Receptor, indirect waste
Sinks
Urinals
Wad Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater : • or vent
Indus -1 waste treatment
intercep •• , including trap
and vent, tt,cept for kitchen
type grease terceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair 4i alteration of
wat /piping and/or water
tre ent equipment
Repair or alt = lotion of
drainage or ve •iping
,.3
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
/
/
iI
ackflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protectiv evice
other than atmosphere' - pe
vacuum breakers over `::
inch (51 mm) diameter `�
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in ;
lawn sprinkler backflow: -`
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:1Appli cations \Porrns- Applications On- Linet2009 Applications1l -2009 Permit Applicatian.doc
Revised: 1 -2009
bh
Page 5 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0004800003 Permit Number: D10-100
Address: 12610 INTERURBAN AV S TUKW Status: APPROVED
Suite No: Applied Date: 04/15/2010
Applicant: POINT TO POINT TRANSPORTATION Issue Date:
Receipt No.: R10 -00835
Initials: WER
User ID: 1655
Payee: DACO
Payment Amount: $264.20
Payment Date: 05/13/2010 02:40 PM
Balance: $0.00
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 206272 264.20
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 259.70
640.237.114 4.50
Total: $264.20
YME ;T
RECEIVED
doc: Receipt -06 Printed: 05 -13 -2010
r
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0004800003 Permit Number: D10 -100
Address: 12610 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 04/15/2010
Applicant: POINT TO POINT TRANSPORTATION Issue Date:
Receipt No.: R10 -00642
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $168.81
Payment Date: 04/15/2010 09:39 AM
Balance: $264.20
DACO
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 206082 168.81
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 168.81
Total: $168.81
P
y T
EVE
doc: Receiot -06
Printed: 04 -15 -2010
Z
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
to - /04
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431 -3670
Pn�aje l
O,� �
t�
pd
Type of Inspection: /�I��
, A- 1
Address:
Date Called:
Special IInn7structions:
ILA S
Date Wanted:
.�
Requester:
Phone No:
6, !
'1 O (0- 9 Ssb
Approved per applicable codes. El Corrections required prior to approval. 7
COMMENTS:
FLRJAA,77,0 )--11
Inspect • r: VI"
'21
'Date :�
r')
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: 'Date:
..kwa ..4,.. tt
-4:14
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Q(v –f6J
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
P�o Iect: rhi ia .
�M C•
Type Igspe cti n: p ' t
(,, i A eA &) t o
G
Address:
2-('(v
er,Jf
Date Called:
#0 (e %l 0J-e c` F . e
Special Instructions:
S,��(e Lau Er 4.417-5
loAl ri(� ��J3(
Date Wanted: -� , l
5-20-(d "(d
a.rp,.
P.m.
Requester:
A- L t
Phone 1, 4v6 -1.5-51
ElApproved per applicable codes.
orrections required prior to approval.
COMMENTS:
t) S1"-,e1 or ke c-,rk 3 .. ( f
t i4: c.. -A-r P) ii,71 M R-jc t c.D k- /q
A-
ca1\ P b.. _ ()-\, r e..f -') of - 1
S (ft Al\ .1 e - (4-JO r
L) & AU 1k' - ??d ) C'J ^k
–,
#0 (e %l 0J-e c` F . e
kc
U) Imo-- c 4 0 I (If ' f_J- ,�f.
L.,
6 f r e r -r-\ 1 Li-e
i L4)
,n
A- L t
3 Ms,� Ae C-; /-,A 1 eit c
(- r -A i l c.-1)-:.3^ Al -e-A
i_--.51
- 1 1
Date:
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.,,Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit A
PERMIT NUMBERS
• CITY OF TUKIMILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 .206- 575 -4407
Project:
Sprinklers:
Type of Inspection:
RA....
Address: it). 6 / 0
Suite #:
Pc S
Coptact Person:
C' / , cs-k i
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
ir .4staJk perm a�r ��i )(i
f
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor: —
Pre -Fire:
Permits: •
Occupancy Type:
Ilnspecbor:
/
T
Date: 51/9/>l,
Hrs.:. 1
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
. r'
Word/Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
May 24, 2010
OTTO ROSENAU & ASSOCIATES, INC.
Gttechnical Engineering, Construction Inspection & Materials Testing
•••01 6747 M. L. King Way South, Seattle, Washington 98118 -3216 USA
�k 06) 725 -4600 • Toll Free: (888) OTTO -4-US • Fax: (206) 723 -2221
``�W2F5913684 • WABO Registered Agency • Website: www.ottorosenau.com
Ot
FINAL REPORT
City of Tukwila Building Department
6300 Southcenter Blvd, Suite 100
Tukwila, Washington 98188 -2544
Project: Point to Point Permit Number: D10-100
Address: 12610 Interurban Avenue South, Tukwila Job Number: 10 -0243
We state that the work requiring special inspection was, to the best of our knowledge, in conformance
with the approved plans and specifications and the applicable workmanship provision of the building
code. Our knowledge is limited to our reports.
All typewritten reports have been mailed to your office or are enclosed. All reports appear to be
complete. This report should not be considered as a warranty for conditions and /or details of the
building.
Items inspected are:
1. Anchor bolt installation
Sincerely,
OTTO ROSENAU & ASSOCIATES, INC.
514402/1 eeenau -11149_<
Susan Rosenau -Moser
Vice President
Attachment
Email c: Daco Corporation Attention: Mr. Rich Fisher
OTTO ROSENAU & ASSOCIATES, INC.
Geotechnical Engineering, Construction Inspection & Materials Testing
RECEIVED
MAY 25 20101
L.vr+iimuwl1 Y
DEVELOPMENT
PROPRIETARY ANCHOR MECHANICAL INSPECTION REPORT
Job Number: 10 -0243
Report Number: 117267 Permit Number: D -10 -100
Project: Point to Point Client: Daco Corp.
Address: 12610 Interurban Ave S, Tukwila Address: 18715 East Valley Hwy, Kent
Inspector: Darren Reid Date: 5/18/2010
Description /Location: ' /Z" by 4'A" Hilti KB TZ placed (2) per base plate along B.9/2 -6 for (8) bays of shelving.
Intended Use: Shelving Base Plate Anchors
Building Code & Year:
Comments
All anchors placed and torqued to 40ft/Ib per manufacturers specifications and city approved plans required.
Reference Standard(s) Used:
Copies to:
X Client Engineer
Owner Contractor
Architect X Building Dept.
Others
Technical Responsibility:
Conforms X Does Not Conform
7RabCO an r
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1- 888 - OTTO -4 -US - Fax (206) 723 -2221
Form No.: ADMIN -87 -01 (Rev 7/09)
Anchor Size & Quantity:
Anchor Type: 0 Expansion • Screw • Sleeve • Drop In
ESR Number: 1917
Anchor Manufacturer: Hilti KB -TZ
Hole Diameter: '/"
Hole Depth: (4) 4'/2"
Required Embedment: 3' /e"
Anchor Length: 4 Yz
Concrete Thickness: Slab 6"
Concrete Strength:
Base Material: ►■ Normal Weight Concrete • Light Weight Concrete
• CMU
• Brick ■ Composite Deck
Hole Cleaning: @ Compressed Air •
Hand Pump • Other:
ORA Torque Wrench ID: 5998
Torque: 40
ft -Ibs
Drill Bit (ANSI B212.15): ►5 Yes • No
Weather: Cloudy
Ambient Temperature: 68° inside
Comments
All anchors placed and torqued to 40ft/Ib per manufacturers specifications and city approved plans required.
Reference Standard(s) Used:
Copies to:
X Client Engineer
Owner Contractor
Architect X Building Dept.
Others
Technical Responsibility:
Conforms X Does Not Conform
7RabCO an r
This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report,
except in full, without written permission from our firm is strictly prohibited.
Page 1 of 1
6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1- 888 - OTTO -4 -US - Fax (206) 723 -2221
Form No.: ADMIN -87 -01 (Rev 7/09)
By G. OHANIAN
DATE 3-31-10
SUBJECT
RAdK DENIdN & ENOINEERINGt do.
412 wEttr BROADWAY, QUITE #204
I.ENDALE, CA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
SHEET NO 1
JOB NO.. RD -14735
STRUCTURAL CALCULATIONS OF STORAGE
RACKS FOR:
POINT TO POINT
1 261 0 INTERURBAN AVE. SOUTH
TUKWILA, WA. 98168
PER IBC 2006 EDITION
SECTION 2208
STORAGE RACKS CAPACITY:
1400 # / LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD -14735
r
EXPIRES 12 -26 -11
REVIEWED FOR--
CODECOMPLIANCE
APPROVED
MAY 12 2010
Qkyof Tukwila
BUILDING DIVISION
bLO 100
RECEIVED
APR 15 2010
PERMIT CENTER
BY G. OHANIAN
DATE 3 -31 -10
SUBJECT
RAdK DEOI(N & EN(INEERIN(4 d0.
412 WET BROADWAY, BUITE #204
LENDALE, dA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
SHEET NO 2
JOB NO.. RD -14735
FRONT VIEW
BEAM
M= 120 "X.7 K =1 1 "K
8
S R= 33 K= •32 <•56
0= 5xWxL3 =.55 "< 120 =.66"
384x1, xE 180
LOAD PER BEAM + 25% IMPACT LOAD =
(1.4KX.88) +(.7Kx.25)= 14.4-= .7K
BEAMS
Ix =.98
S,=.56
Fy =55 KSI.
SEISMIC DESIGN
V= 5—Q-92—(1 xWx.75x.67 IBC 2006 —SEC. 2208, PER RMI SPECS.
ASCE 7 -05 (SEC. 15.5.3)
S0S =.98 (USGS WEB SITE, "SITE CLASS D ")
1 =1 NO PUBLIC ACCESS
R =6 MOM. CONN.
R =4 BRACED
W =D.L.+ 3 PALLET LOAD
LOAD PER COLUMN
PALLET LOAD= 2 X 3x1.41( =1.4K
3 2 coL.
W =.2DL+ 1 .4 P� 1.6 K
vLONGIT. ' 13 K
K
TRANS. '20
LONGIT. SEISMIC
Conterminous 48 States
2005 ASCE 7 Standard
Latitude = 47.489
Longitude = — 122.2796
Spectral Response Accelerations SMs and SM1
SMs = Fa x Ss and SM1 = Fv x S1
Site Class D — Fa = 1.0 ,Fv = 1.5
Period Sa
(sec) (g)
0.2 1.480 (SMs, Site Class D)
1.0 0.764 (SM1, Site Class 0)
Conterminous 48 States
2005 ASCE 7 Standard
Latitude = 47.489
Longitude = — 122.2796
Design Spectral Response Accelerations SDs and SDI
SDs = 2/3 x SMs and SDI = 2/3 x SM1
Site Class D — Fa = 1.0 ,Fv = 1.5
Period Sa
(sec) (g)
0.2 0.987 (SDs, Site Class D)
1.0 0.510 (SDI, Site Class D)
.13 K
4"k
BY G. OHANIAN
DATE 3-31-10
SUBJECT
RACK DEOD N & ENdINEERINGI CO.
412 WEcriT BROADWAY, FlUITE #204
LENDALE, dA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
SHEET NO 3
JOB NO.. RD -14735
COLUMN ANALYSIS
x-
l
Fy =55 KSI
A =.78
S=.80
rx =1.2
ry =1.1
COMBINED STRESS RATIO
P +M =� +26 = .27<1.0
a ax
BASE PLATE
ANCH. TENSION = 4 —(1 .6x3") =0
ANCHOR SHEAR = • 13 = 07 K
2
(2) -1/2 "95 HILTI KWIK BOLT —TZ ANCHORS
(ESR -1917) PER BASE PL., 3 1/4" EMB.
SPECIAL INSPECTION IS REQUIRED
MOMENT AT BEAM CONNECTION
.5x.07x1x65 =2.3K BEARING CAPACITY
OF COL. HOLE
KI 66x1.7 =94 2
Fe= 7TxE —32
rx --",2 ( KI )2—
Tx'
KI __ 52 __ 47 F
Ty- Fn =Fy (1— _)=.32 KSI
Max =Sx .Fb =26
"K
7/16 "0 RIVET
A = .1 Fy = 79 KSI
Pa = .1 x79x.4 = 3 K
Ma = (2.3Kx4 ") +(1.2Kx2 ")= 11.6 "K 3 PIN CONN.
CONN.
MEND= .01xWI2= .8 "K
M = 3.5K M = 4.3"K
SEISMIC TOTAL
Pn =Fn xA= 25 K
Pa = -13K
a - 1.92 -
1.6 K
7 3/4 "x5 "x3/8"
BASE PLATE
3 "K
3.5 "K ' ® �� 3.5 "K
4 "K
BY G. OHANIAN
DATE . 3 -31 -10
SUBJECT
RAdK DE$I(N & ENGIINEERINGI do.
412 WEctiT BROADWAY, plUITE #204
LENDALE, CA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
SHEET NO 4
JOB NO. RD -14735
OVERTURNING
MOT '20 Kx2oox(198 " +20 ")x.66 =57 "K
MR = 1.6 Kx42 "x.6 = 40 "K
UPLIFT = 57-40 .40
240 = K
.20 K
.o
CL
.20K
42"
LOAD TO DIAGONAL
P = .20 Kx cx 56 = .53 K
COL
Fy =55 KSI
A =.31
rx =.48
Q =.74
L= 56"
CHECK WELDS
Fa = 1 1.2 KSI
Pa = 3.5 K
1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL)
3x.125x.707x70x.3 = 5.7 K
CHECK SLAB
1600 — — a'
1000 1'6
1.6x144=230 °"
=15"
M= (11-)2X1 2 )000x 1 x12 =94"#
5= 12x52 = 50
6
94 = 2 <1.6 x/2500 =80
50
co
N
TOP LEVEL LOADING
W= .2pI +.7LL =.9 K
V= .11K
LOAD PER COL.
MOT =.1 1 KX2 COL X(198 " +20 ") = 48 "K
MR = .9 Kx42 "x.6 = 22 .K
UPLIFT = 4 4222 = .62 K
BOTH SIDES NP
, x x
t =.07"
1600 #
5" CONCRETE SLAB
2500 PSI. CONC.
1000 PSF. SOIL
DACO
MATERIAL HANDLING &
PACKAGING SOLUTIONS
April 14, 2010
Al Metzler
City of Tukwila Fire Department
Fire Safety & Inspection
444 Andover Park East
Tukwila, WA 98188
Dear Al,
Offetopv
.. ,
C REVIEWED FOR
�ECOMPLIANCE
PP�OVED
i�iMr 12 2010
Qty of Tukwila
BUILDING DIVISION
This permit is for one (1) single row of selective pallet rack on the east wall of this building.
The commodities to be stored on this rack are Exhibit Properties and Trade Show Equipment.
Some of this equipment will be stored in plastic shipping bins and the remainder will be stored
on wood pallets and will not be encapsulated.
The existing sprinkler system is rated at .3$GPM over 5600 Sq. Ft.
,37
Sincerely,
Rich Fisher
Territory Manager
bO 100
RECEIVED
APR 15 2010
PERMIT CENTER
•
it 1 1 kf PY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -100 DATE: 04-15-10
PROJECT NAME: POINT TO POINT TRANSPORTATION
SITE ADDRESS: 12610 INTERURBAN AV S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter
Revision # After Permit Issued
DEPARTMENTS:
iding Division
Public Works ❑
AVM'\ SI■ .I cA-)
Fire Prevention
Structural ❑
Planning Division
Permit Coordinator
L_I
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
n
DUE DATE: 04-20-10
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route tg Structural Review Required ❑ No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05-18-10
Approved ❑ Approved with Conditions t Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Peer Friendly Page
1
General /Specialty Contractor
A business registered as a construction contractor with LEl to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name Daco Corporation UBI No. 601946293
Phone 4256564504 Status Active
Address 18715 E Valley Hwy License No. DACOC "012NC
Suite /Apt. License Type Construction Contractor
City Kent Effective Date 9/10/1999
State Wa Expiration Date 5/1/2012
Zip 980321241 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty 2
Effective Date
Expiration Date
Status
DACO "'101 JC
Daco
Construction Contractor
General
Unused
4/3/1990
3/13/2000
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
Katona, B Kevin
President
05/01/1999
Amount
Duffield, Stephen L
Vice President
04/16/2010
01C11875962
Shields, Edward E
Chief Executive Officer
01/01/1980
09/29/2005
Bond Information
Page 1 of 1
Bond
2
Bond Company Name
DEVELOPERS SURETY
ft INDEM CO
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
857388C
05/01/2002
Until Cancelled
$12,000.00
04/10/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
7
AMERICAN
STATES INS CO
01C11875962
05/01 /2009
05/01 /2011
$1,000,000.0004
/28/2010
6
AMERICAN
STATES INS CO
010E586771
05/01 /2005
05/01 /2009
$1,000,000.00
04 /17/2008
5
AMERICAN
STATES INS CO
010E5867716
05/01/2004
05/01/2005
$1,000,000.00
04/22/2004
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
05/13/2010
C3
N
O
N
(A)
PJ
CONF. RM.
104
:z? rz!_ 7ZZ— zL.- , .:. 1 Z7.: J1 : �
PJ
J
LO
N
0
0
N
X
36" EXTERIOR DOO
F—
w
OFFICE
103
OFFICE
102
RECEPT.
101
eas .:
6"
x
X
15' -10z"
r
PA
50' -0"
PJ
50' -0"
PJ
! ®FE
OPEN OFFICE
105
®FE
� 7
I,
w
I\ /1
1 \/ 1
1 /\ 1, ,ii-"
1/ (
I\ /I
\/
1 /\ I
I/ \1
I\ %
I \/
/\ 1
I/ \{
I \/ I
I /\
1/ \1
I \k/
I /` SUITE 'C'
1,616 SF OFFICE; 10,384 SF WAREHOUSE
PJ
NEW SINGLE
TENANT ONE
WAREHOUSE
107
EXISTING RACKS TYPICAL
{`(rt
ROW RACK
E�
11
4'2
M
PJ
®FE
N
X
0
N
N
X
O
N
N
X
0
N
N
X
0
N
X
Co
X
to
rN - - �
1l— i l � -- >�II�\- -� -t -i \ ��II`-_flT -;.— iI i1 II i1 II i< Ifl5-T; < 11. i1 I iI i< II i< 11
l -_- �(1� �,II ' _ jI ' - -- JIB---- �ll� - - - -- III - - - -_ �---- �II�: _-- _-JL� - - - -�
,1 I I I ■
- -.
PJ PJ PJ I
RACKING PLAN
SCALE: 1 /8 " =1 '--0"
x X
REVISIONS
R
X
Cr)
EXIT
®FE
PJ
48" EXTERIOR DOOR
W/ EXIT SIGN
GENERAL NOTES
SYMBOL LEGEND
EGRESS ROUTE
— REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 12 2010
City kwila
BUILDING IVISIGN
96 X 42
SEPARATE PERMIT
REQUIRED FOR:
4v1eChanical
Alai Electri
)lumbing
as Piping
City of Tukwila
BUILDING DIVISION
ELEVATION
0)
1
0)
VIEWS
SCALE: 1/4-"= 1 ' -0"
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a riew plan submittal'
and may include additional plan review fees. I
EGRESS NOTES:
1. WAREHOUSE EGRESS TO BE NOT MORE THAN 200'
TO ANY ONE EXTERIOR DOOR.
120 X 42
AREA OF WORK
V
PRE COPY
Permit No.. ' O — /(9O
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By
Date:
S// 3 42-0( d
City Of 1Ukwiia
BUILDING DIVISION
VICINITYIKEY PLAN
SCALE: NONE
2
RECEIVED
APR 15 2010
PERMIT CENTER
PROJECT:
TUKWILA COMMENTS
Sow Point
12610 Interurban Ave S
Tukwila, WA 98138
MATERIAL HANDLING &
PACKAGING SOLUT /ONS
CONTRACT WITH:
18715 East Valley Highway
Kent, WA 98032 -1241
(425) 656 -4505
Sow
12610 Interurban Ave S
Tukwila, WA 98138
DESIGNER:
DATE:
SCALE:
AHJ
BID #
JOB #
NOTED
SHEET #
R1 of
I0
e
a"
•
.0
•
44
e'
7/16"O RIVET
ASTM A576 -90B
t= 3/16"
(2)-1/2"O ANCHOR BOLTS PER BASE PLATE
3 1/4" EMB., (SEE NOTE NO. 4)
BRACING DETAIL (1
BEAM CONNECTION (2 BASE PLATE DETAIL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 12 2010
City of Tukwila
BUILDING DIVIGInto
1
120" & 96"
1
GENERAL CONFIGURATION
S
N
N
N
S
N
NOTES:
1— DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS
AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS
OF THE INTERNATIONAL BUILDING CODE 2006 EDITION, SECTION 2208
2 —STEEL FOR ALL SHAPES FY =55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED)
3 —NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP
OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES)
4 —ALL ANCHORS HILTI KWIK BOLT -TZ (ESP -1917)
SPECIAL INSPECTION IS REQUIRED
5— CONCRETE SLAB 5" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF
6— STORAGE RACK CAPACITY 1400 #/ LEVEL
7 —RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS
A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY
OF THE RACK (1400 #/ LEVEL)
8— STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE
VERTICAL OF 1/2" IN 10' -0" OF HEIGHT
9 —THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES
BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR.
RACK DESIGN AND ENGINEERING
412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204
SCALE: NONE
DATE: 3 -31 -10
PROJECT:
FRONT VIEW
SIDE VIEW
EXPIRES 12 -26 -11
DRAWN BY: .AS J
POINT TO POINT
12610 INTERURBAN AVE. SOUTH, TUKWILA WA. 98168
STORAGE RACK DETAILS JOB
RD- -1414
735
SHEET NO.
1 OF 1
1////—:
0
co
1 S
CO
\
c
co
c
\
r
'r
LIc
1
r
1( jr
GENERAL CONFIGURATION
S
N
N
N
S
N
NOTES:
1— DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS
AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS
OF THE INTERNATIONAL BUILDING CODE 2006 EDITION, SECTION 2208
2 —STEEL FOR ALL SHAPES FY =55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED)
3 —NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP
OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES)
4 —ALL ANCHORS HILTI KWIK BOLT -TZ (ESP -1917)
SPECIAL INSPECTION IS REQUIRED
5— CONCRETE SLAB 5" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF
6— STORAGE RACK CAPACITY 1400 #/ LEVEL
7 —RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS
A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY
OF THE RACK (1400 #/ LEVEL)
8— STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE
VERTICAL OF 1/2" IN 10' -0" OF HEIGHT
9 —THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES
BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR.
RACK DESIGN AND ENGINEERING
412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204
SCALE: NONE
DATE: 3 -31 -10
PROJECT:
FRONT VIEW
SIDE VIEW
EXPIRES 12 -26 -11
DRAWN BY: .AS J
POINT TO POINT
12610 INTERURBAN AVE. SOUTH, TUKWILA WA. 98168
STORAGE RACK DETAILS JOB
RD- -1414
735
SHEET NO.
1 OF 1