Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D10-105 - DHS - BUILD OUT
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. D10 -105 Department of Homeland Security 12500 Tukwila International Boulevard RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = Brief Explanatory DeSctiptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that Personal Information — social security numbers are a private concern. As such, individuals' social security numbers are Social Security Numbers redacted to protect those individuals' privacy pursuant 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. to 5 U.S.C. sec. 552(a), and are also exempt from 552(a); RCW 552(a); RCW disclosure under section 42.56.070(1) of the 42.56.070(1) 42.56.070(1) Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card Personal Information — numbers, electronic check numbers, credit expiration 27 DR2 Financial Information — dates, or bank or other financial account numbers, RCW RCW 42.56.230(4 5) which are exempt from disclosure pursuant to RCW 42.56.230(5) 42.56.230(5), except when disclosure is expressly required by or governed by other law. DEPARTMENT OF H 1 MELAND SECURITY 12500 TUKWILA INTERNATIONAL BL D10 -105 Cityllf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 7340600602 Permit Number: D10 -105 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Issue Date: 05/13/2010 Suite No: Permit Expires On: 11/09/2010 Tenant: Name: DEPARTMENT OF HOMELAND SECURITY Address: 12500 TUKWILA INTERNATIONAL BL , FLOOR 3 Owner: Name: INTERNATIONAL GATEWAY EAST LLC Address: 12201 TUKWILA INTL BLVD 4TH FLR , SEATTLE WA 98168 Phone: Contact Person: Name: MARCUS MCFARLAND Address: 12201 TUKVVILA INTERNATIONAL BL 4TH FLOOR , TUKWILA WA 98168 Phone: 206 - 730 -6578 Contractor: Name: SABEY CONSTRUCTION INC. Address: 12201 TUKVVILA INTERNATIONAL BLVD , SEATTLE WA 98168 Phone: (206)281 -4200 Contractor License No: SABEYCI033KM Expiration Date: 01/12/2011 DESCRIPTION OF WORK: BUILD OUT OF 3,584 SQUARE FEET OF OFFICE SPACE IN EXISTING BUILDING WITH NEW WALLS, CEILING, HVAC & PLUMBING Value of Construction: $206,827.00 Fees Collected: $3,889.67 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: I -A Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -10/06 D10 -105 Printed: 05 -13 -2010 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.c i. to kw it a. wa. us Permit Number: D10 -105 Issue Date: 05/13/2010 Permit Expires On: 11/09/2010 Public Works Activities: C.hannelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction r the perform e o o I am authorized to sign and obtain this development p rmit. Signature: Date: crr 3 /mod /O Paint Name: Sair6a �' p�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended ox abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -105 Printed: 05 -13 -2010 Parcel No.: 7340600602 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 12500 TUKWILA INTERNATIONAL BL TUKW DEPARTMENT OF HOMELAND SECURITY Permit Number: Status: . Applied Date: Issue Date: D10 -105 ISSUED 04/19/2010 05/13/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: Special inspection for sprayed fire- resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire- resistance design as designated in the approved construction documents. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 19:: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 15: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: Cond -10/06 D10 -105 Printed: 05 -13 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 17: ** *FIRE DEPARTMENT CONDITIONS * ** 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (WC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 2) : Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having doc: Cond -10/06 D10 -105 Printed: 05 -13 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 31: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 32: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 3:3: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 34: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 35: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 313: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 37: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 313: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 39: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire P:revention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 40: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 41: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 42: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth doc: Cond -10/06 D10 -105 Printed: 05 -13 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us in Table No. 803.5 of the International Building Code. 43: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 44: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 48: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -105 Printed: 05 -13 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: /41-"—$ Print Name: YV 1 C45 1 Date: i /�V0' o doc: Cond -10/06 D10 -105 Printed: 05 -13 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tulcwila.wa.us Building Permit No. 1) 10— Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) • tic Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12500 Tukwila International Blvd. Tenant Name: Department of Homeland Security Property Owners Name: Intemational Gateway East III, LLC Mailing Address: 12201 Tukwila Intemational Blvd. 4th Floor King Co Assessor's Tax No.: 7340600602 Suite Number: Floor: 3 New Tenant: ❑ Yes ®..No Tukwila WA 98168 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Marcus McFarland Mailing Address: 12201 Tukwila International Blvd. 4ht Floor E -Mail Address: marcusm @sabey.com Day Telephone: (206) 730 -6578 Tukwila WA 98168 City State Fax Number: (206) 282 -9951 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Sabey Construction Mailing Address: 12201 Tukwila Intemational Blvd. 4th Floor Contact Person: Marcus McFarland E -Mail Address: marcusm @sabey.com Contractor Registration Number: SABEYC1033KM Tukwila WA 98168 City State Zip Day Telephone: (206) 730 -6578 Fax Number: (206) 282 -9951 Expiration Date: 01/12/2011 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Halzelrigs Architecture & Design, pllc Mailing Address: 5700 Corson Ave. South Seattle WA 98108 Contact Person: Colleen Halzelrigs E -Mail Address: Colleen @HazelrigsArchitecture.com City State Day Telephone: (206) 957 -0611 Fax Number: (206) 957 -0612 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications\Porms- Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 206,827 Existing Building Valuation: $ 29,696,000 Scope of Work (please provide detailed information): Build out 3,584 square feet of office space in existing building with new walls, ceiling, HVAC & plumbing. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If ''yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 2nd Floor 3rd Floor 33,973 3,584 1 B Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If ''yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: G o;�1',NER OU RIZ AGENT: /8 /a �0 [[//%]� Date: 'S' o Print Name: P4a"'CUS V " ' v Gam// /C�JJ I Day Telephone: �' 730-- 6-S 7r� Mailing Address: /A:20/ `-ct,i i; jot �e��ta he ::af / �v� 7'hG t / - tAJA- 9768 City State Zip Date Application Accepted: 1+4°1 -( Date Application Expires: 10- ( — Staff Initials: H:Wpplications\Forms- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 7340600602 Permit Number: D10-105 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 04/19/2010 Applicant: DEPARTMENT OF HOMELAND SECURITY Issue Date: Receipt No.: R10 -00666 Payment .Amount: $3,889.67 Initials: WER Payment Date: 04/19/2010 03:02 PM User ID: 1655 Balance: $0.00 Payee: MARCUS MCFARLAND TiRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 01939B ACCOUNT ITEM LIST: Description 3,889.67 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $3,889.67 2,354.65 1,530.52 4.50 P YMENT RECEIVED doc: Receiot -06 Printed: 04 -19 -2010 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr 0l 0M �i 4 Se cot-' Q sf-�1 � r� Typ f,lnA Ati� n: Bch s \ :! ' Address t 1 _ S p4 Special Instructions: (b.4 28 i) 3 l (3('' 3y ik". twArts ,.)p Date Wanted: --. �r -- �a.m:_ p.m. Requester: Phone Go_25S-3C`1I Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: r old`' G-0 p le_je kow-P-5- - .21 Inspect J Date`'14) ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ..a40Ae..9 .yt a, sw±Q .:.star.: ,rs INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (2- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prqje iir , t (A-tg i Arm 4 Type I 1 cz--, /k Addres c0c� T 3 Date Called: 7 Speciarinstructions: .. Date Wanted ,� C7'3 ft0 a.. p.m. Requester: Phon2 No: (— ZS5 — 3 0 4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect r: El $60.00 REINSPECTION FEE REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ,�� 3 _ ' J Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 £ ? c -OS- Projgct: r - ` de R l j H T pe 0- srection: a (� Cwt ` a e -s e CJt zt p, (� ✓ Address: t Z TX J0o & ate Called. Special Instructions: 04 2! 1 ( _ ()`i 3 `X • Date Wanted �`� / ` ,�a_mm © p.m. Requester: Phone No( 2_55 -3 (O 7 1 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspect�r: Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: #1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 lc) —iv 5 Proj t: OPkt( 6 AA Sec-Lit Iry Type of Inspection: ,bra ,c.--,'^ 6 Address: . 5 Date Called: �— w_ /2-5d0 Special Instructions: 2 —J1 / O r 1 ] U Date Wanted: �' ' /0 5 m. 1).m. Requester: Phone No: ?,o(o-7S5 - 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ntic J.\ /AJNI )LP. r K-- c./\ d A e S �� 9 e o, TSB L Inspectct „kAut)(,) Dater 76 -/J ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �•athfT_� Mii. a�.' �+' �n^"' �:„ F2EY+-..: i�.? AfiWf>, n145' W°. "Hi?c,'dtPJ�':,$S1:b.A1P.U'{/:: _ '. INSPECTION NUMBER Burg tLGnY7..'h1.R r3rr N�ei.94.a.z.P.?TA4Wi!.t$S 1�7YA•}A%. .. INSPECTION RECORD Retain a copy -with permit PERMIT NUMBERS CITY OF TUI VVILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: 0/./Z S C, 5 Fire Alarm: Type of Inspection: Fi4 6,.../.4i.- Address: 12 S� Suite #: 7-, 6 rt 30o -- - - - -- -- - - - -- Contact Person: C�}�/,���/� A 1, fici <' Cj,I,'2 TY Y� Special Instructions: . Occupancy Type: Phone No.: , . C) 4 £,A oZ 65- Approved per applicable codes. nCorrections required prior to approval. COMMENTS: ./.), 4. Jac . 1."4....." a it Q psi o� ceu£,.'o - pee /e5 ol.? Needs Shift Inspection: Sprinklers: Fire Alarm: y Hood & Duct: Monitor: t.�,4d.6.Le Pre-Are: Permits: Occupancy Type: Inspector:- , _ "c 4 /soil( I Date: 4//4/10. , Hrs.: • .. y" . ' l n $80.00 REIN PECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department: 'Call to schedule a reinspection. Word /Inspection Record Form:Doc 1/13/06 • T.F.D. Form F.P. 113 nits INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit fo. o 7a PERMIT NUMBERS CITY OF TUKVVILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: J/) L S - @ c_ t O Type of Inspection: e Address: /2- 5 o0 7'8 Suite #: 300 Contact �.P /person: �r M5'th- 1fi/ /,4=) Special Instructions: Phone No.: 2/14— 06 i1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: 4 Fire Alarm: - Hood & Duct: I - Monitor: totie...p ;A.- Pre -Fire: Permits: - a Occupancy Type: - - 4/44Y. 4 /4✓ 4,. d t` 1 -- .e_ . — ry -e._ .41., ea 6 I. ire- Se no6 .e a/ / I fl I J 6 /4-1 _ + M l 4 / . 1 t l y t ok- iw' i see t dl - 4 Avove 4'l "/ 3 ,P4-,/,05-5 63,•4/.e.4 "le e...41 444 ; (e -et a.. ■1■4 4,,,. ddk.. Needs Shift Inspection: y Sprinklers: 4 Fire Alarm: - Hood & Duct: I - Monitor: totie...p ;A.- Pre -Fire: Permits: - a Occupancy Type: Inspecto , -. • • • Date: 6b 1 , g/ t O IHrs.: /,.t) sogorg n $80.00 REINS ECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule 'a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Piro -1 °5 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: a#4,41,-.4. .,.//44.14.4.. %,,,/ S r,,.;,G, Type of Inspection: Address: 1 z Too Suite #: ? i °t- . glddt Contact Person: GtL at i- " �, ,.r -;1,. Special Instructions: Phone No.: € d.,,, a a A . Approved per applicable codes. Corrections required prior to approval. COMMENTS: (o./l' Q- L a J ✓Q .,5 IA., i c e r1 /; f/ Joe) - 5 lei, .11 1 r,� if 7dQfa tot, 4 t E ■ ,�ed �e 16f4 1/ E G G /cg (/ 3 T "I". I". '1 r /.fir M 51o1/ ire d* 51 Needs Shift Inspection: Sprinklers: k. Fire Alarm_ : Hood & Duct: Monitor: Pre -Fire: Permits: • Occupancy Type: . • inspector': '' is,L____ I Date: /11 /in -- Hrs.: 7. to • n $80.00 REINSCTION FEE REQUIRED. Yobs will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit IO'--a Ala. - 1.0 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206- 575 -4407 1 Project: 1) ki. s- 5 -'"i,. Type of Inspection: v H`t t -o (v-er Address: /'a �" po Suite #: -T J. f Contact Person: Special Instructions: • Phone No.: pproved per applicable codes. 1 1 Corrections required prior to approval. COMMENTS: psi" 0-30 5 atlo .° - C,,40-er Needs Shift Inspection: 5 -'"i,. Sprinklers: Fire Alarm: Hrs.: a Hood & Duct: Monitor: • Pre -Fire: Permits: Occupancy Type: Inspector: 5 -'"i,. 1 Date: 'L3-/ /0 Hrs.: a $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Cali to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ,r April 20, 2010 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Marcus McFarland 12201 Tukwila Internatioanl BI 4th Floor Tukwila, WA 98168 RE: Incomplete Letter #1 Development Permit Application D10 -105 Department of Homeland Security —12500 Tukwila International BI Dear Mr. McFarland, Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 19, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: .Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the attached comment in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, a:AINCtAtl- Bill Rambo Permit Technician Enclosures File: D10 -105 W:\Permit Centeruncomplete Letters \2010\D10-105 Incomplete Ltr #1.DOC 6.300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: April 20, 2010 Project Name: Department of Homeland Security Permit #: D10 -105 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide an emergency egress plan. The plan shows more than 49 occupants; therefore two means of egress shall be required. Show provisions for two means of egress. Show emergency illumination for each common path of egress path and show illuminated directional path and door exit signs. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. *ER IT MORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D10 -105 DATE: 04/28/10 PROJECT NAME: DEPARTMENT OF HOMELAND SECURITY SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: VA) birl B iang Ivision i Public Works Fire Prevention ❑ Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Nt Comments: Incomplete DUE DATE: 04/29/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Building Please Route ixt Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/27/10 Approved ❑ Approved with Conditions 14 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • PE 'a: 1 tc '., ,IW �. 4 PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -105 DATE: 04 -19 -10 PROJECT NAME: DEPARTMENT OF HOMELAND SECURITY SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # Revision # After Permit Issued DEPART ENT : u-lr� uilding Divi ion L;_I Xicwo s rJ PtAQ s , c �o �o M i1 //� Fire Prevention j Planning Division Structural ❑ Permit Coordinator 4°-1° DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04 -20-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LA—).-0-115 LETTER OF COMPLETENESS MAILED. Departments determined incomplete: Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -18 -10 Approved n Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • City of Tukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4/28/2010 Plan Check/Permit Number: D10 -105 • Response to Incomplete Letter # 1 O Response to Correction Letter # O Revision # after Permit is Issued O Revision requested by a City Building Inspector or Plans Examiner Project Name: Department of Homeland Security Project Address: 12500 Tukwila International Blvd. Contact Person: Marcus McFarland Phone Number: (206) 730 -6578 Summary of Revision: Revised egrees plan to show exit way signage. Updated lighting plan shows emergency pathway lighting. Removed the extra chairs on the furniture plan, occupancy load is 36 max. eft cie"wcu REC 2010 "eRmrr corm) Sheet Number(s): 1A-0.0, 1A-1.1 & 1A-1.2 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: in Permits Plus on H:WpplicationsWorms- Applications On Line \2009-08 Revision Submittal.doc Created: 8 -13 -2004 Revised' 8 -2009 Contractors or Tradespeople Pir Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Sabey Construction Inc 2062814200 12201 Tukwila Intl Blvd 4TH FLOOR Seattle Wa 981685121 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601532164 Suspended SABEYCI033KM Construction Contractor 5/14/1997 1/12/2011 5/1/2010 General Unused ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SABEYC'953RE Sabey Corporation Construction Contractor General Unused 12/5/2005 12/5/2011 Active DASCOC`066KD D A 5 Construction Corp Construction Contractor General Unused 5/4/1994 5/4/1997 Archived BERKLCI088CE Berkley Construction Inc Construction Contractor General Unused 2/5/1992 2/5/1993 Archived ARCHIDG132QZArchitectual Dev Group Inc Construction Contractor General Unused 11/9/1987 11/9/1992 Archived SABEYC'141PH Sabey Corporation Construction Contractor Unused General 10/8/1986 12/31/2001 Archived OWPR01'221RR 0 &Amp; W Properties Inc Construction Contractor General Unused 12/19/1978 10/1/1986 Archived BERKLS'267LP Berkley Structures Inc Construction Contractor General Unused 6/17/1974 12/31/1991 Archived Business Owner Information Name Role Effective Date Expiration Date Sabey, David A &Nbsp; 01/01/1980 Bond Amount Poole, Laurent D &Nbsp; 01/01/1980 52BSBCQ3983 Harmon, James N &Nbsp; 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 HARTFORD FIRE INSURANCE CO 52BSBCQ3983 12/31/2004 Until Cancelled $6,000.00 $12,000.00 12/20 /2004 4 TRAVELERS CAS & SURETY CO 81S103354851BCM 12/31/2001 12/31/2004 $12,000.0012/24 /2001 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 4/21/1994 Until Released Bond $6,000.00 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 17 NATIONAL FIRE INS CO OF HARTFO 2094061165 05/01/2010 11/01/2011 $1,000,000.00 05/04/2010 https://fortress.wa.gov/lni/bbip/Print.aspx 05/13/2010 ABBREVIATIONS ACT ACOUSTICAL CEILING TILE ADJ ADJACENT/ADJUSTABLE Aff ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATELY ARCH ARCHITECT @ AT BLDG BUILDING BLKG BLOCKING 5/5 BUILDING STANDARD BTW BETWEEN CAB CABINET CLR CLEAR/CLEARANCE CLG CEILING CL CENTERLINE COL COLUMN COMM COMMUNICATION COMP COMPOSITION CONST CONSTRUCTION CONT CONTINUOUS CTR CENTER CPT CARPET CT CERAMIC TILE Df DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DR DOOR DWG DRAWING E EAST EA EACH ELEC ELECTRIC ELEV ELEVATION EYST EXISTING EXT EXTERIOR FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET MN FINISH FLR FLOOR FLUOR FLUORESCENT fR FIRE RATED n- FEET FURN FURNISH/FURNISHINGS GA GAUGE GALV GALVANIZED GL GLASS/GLAZING GRD GRADE GWB GYPSUM WALL DOARD NC HOLLOW CORE I-IDW HARDWARE 11M HOLLOW METAL HT HEIGHT 11VAC HEATING, VENTILATING, AIR CONDITIONING IN INCH INCL INCLUDE INSUL INSULATION INT INTERIOR JT JOINT VICINITY MAP SHEET INDEX • JAN Lf MAX MECH MFR MIN MISC MTD MTL N/A NIC N NO NOM NTS OC OPNG OPP ()RIG PERM PL PLAM PLYWD PNT PR R RD REF REINF REQ'D REV RM RO SCHED 5 Sc SECT SHR SIM SPEC SQ STD STL STOR SUSP TEL TV TYP UCR UNO VCT VERT W/ W/O WC WD WKST JANITOR LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NORTH NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD FAINT PAIR RADIUS RUBBER DASE REFRIGERATOR REINFORCING REQUIRED REVISION/REVERSE ROOM ROUGH OPENING SCHEDULE SOUTH SOLID CORE SECTION SHOWER SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TELEVISION TYPICAL UNDER COUNTER REFRIGERATOR UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD WORK STATION IA-0.0 COVER SHEET IA-0.1 SPECIFICATIONS IA-0.2 SPECIFICATIONS, CONT. IA-1.1 FLOOR PLAN, POWER/ COMMUNICATION PLAN / REFLECTED CEILING PLAN IA-1.2 FINISH PLAN, FINISH SCHEDULE AND FURNITURE PLAN IA-2. I WALL DETAILS, CASEWORK ELEVATIONS AND DETAILS PROJECT SCOPE PARTIAL FLOOR TENANT IMPROVEMENT ON THE THIRD FLOOR TO INCLUDE CONSTRUCTION OF PARTITIONS, DOORS, CASEWORK, CEILINGS, FINISHES AND OTHER FEATURES. RaE:131:14WoEveD FO CODE COMPLIANCE Ntli 1 2 2010 PV; City of tokivila BUILDING DIVISION T Fl DEPARTMENT OF HOMELAND SECURITY SEATTLE DISTRICT OFFICE 12500 TUKWILA INTERNATIONAL BLVD. SEATTLE, WASHINGTON 98 I 68 J %VALI\ 4° ZONING: CONSTRUCTION 'TYPE: MR PROTECTION: OCCUPANCY: AREA OF WORK: MIC/L, C/LI, LDR 5714 r • • RE ISTERED HITECI AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT B (OFFICE) 3,584 5f COLLEEN HAZELRIGS STATE OF WASHINGTON OCCUPANT LOAD: APPLICA LE CODES: 3,584/100 = 3G IBC, 2006 EDITION IfC, 2006 EDITION IMC, 2006 EDITION UPC, 200G EDITION WSEC, 200G EDITION WASHINGTON STATE VENTILATION AND AIR QUALITY CODE, 200G EDITION AMERICAN NATIONAL STANDARD ICC / ANSI AI 17.1, 2003 EDITION NATIONAL ELECTRICAL CODE (NFPA 70), 2008 EDITION ;EL COIFY DEFERRED SUBMITTALS: FIRE SPRINKLERS HVAC ELECTRICAL PLUMBING Permit No PLO Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize tile violation of any adopted code or ordinance. Receipt of apprBoyved Field anccondoitions is acknowledged: Date: /TA W07111 0 0 ROOM NUMBER DOOR NUMBER DETAIL REFERENCE BUBBLE FLOOR FINISH SYMBOL (15-##) BASE FINISH SYMBOL WALL FINISH SYMBOL CASEWORK FINISH SYMBOL ELEVATION SYMBOL BREAKLINE SECTION REFERENCE ® KEYNOTE SYMBOL SEPARATE PERMIT REQJJRED FOR: REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. 4CTE: Revisions will require a new plan submittal and may include additional plan review fees. /Mechanical 114/Electrical leelumbing E Gas Piping City of Tukwila ULDNG DIVIS!O APN: 102304-9084-07, I 02304-90.50-01, 734060-0602-03 LOT 6 Of TUKWILA BLA #L03-034 REC #20030725900003 LOCATED IN SE 1/4 OF SEC 9 SW 1/4 10 IN 23-04. LOT 7 Of TUKWILA BLA #L04-060 REC #2004 1 008900012 LOCATED IN SE 1/4 OF SEC 9 * SW 1/4 10 IN. RIVERSIDE INTERURBAN TRS LOT 8 OF TUKWILA BLA L02-057 REC #20030327%0002 LOCATED IN SE 1/4 OF SEC 9 * SW 1/4 I 0 IN 23-04. SCALE: 1" = 60"--0" NORTH cirM APR 2 8 2010 PERMIT CEN w z Cs) EGRESS PLAN PROJECT TEAM OCCUPANT LOAD CALCULATION 3,584 SF (OFFICE) ÷ I 00 SF PER OCCUPANT = 35.84 OCCUPANTS I EXIT REQUIRED, 1 EXIT PROVIDED PROPERTY OWNER: ARCHITECT: COMMON PATH OF EGRESS TRAVEL (93') TRAVEL DISTANCE (107' = 93' + 14') SABEY CORPORATION 1220 I TUKWILA INTERNATIONAL BLVD., SUITE 400 SEATTLE, WA 981 68 206-28 I -8700 (PHONE) 206-281-0920 (FAX) CONTACT: SANDRA SUSKIC EMAIL: SANDRAS@SABEY.COM HAZELRIGS ARCHITECTURE DESIGN, 1911c 26826 5700 CORSON AVE. 5. SEATTLE, WA 98108 20G-957-06I I (PHONE) 253-957-0612 (FAX) CONTACT: COLLEEN HAZELRIGS EMAIL: COLLEEN@HAZELRIGSARCHITECTURE.COM GENERAL CONTRACTOR: SABEY CONSTRUCTION I 2201 TUKWILA INTERNATIONAL BLVD., SUITE 400 SEATTLE, WA 98168 20G-28 I -4200 (PHONE) 20G-281-0920 (FAX) CONTACT: GLENN PARRY EMAIL: GLENNP@SABEY.COM w 0 Cr L Checked by CH 11 \\ 0 0 0 a_ n_ Drawn by C1111, 5G5 Scale Date Job No. AS NOTED 3/9/ I 0 a. 0 cc 0 0 09:007 SHEET NUMBER PROJECT SCALE: I/32' = I '-0" NORTH IA-0.0 © 20101-IAD OUTLINE SPECIFICATIONS DIVISION 0I - GENERAL REQUIREMENTS 01 10 00 - SUMMARY OF WORK I . GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UNO. 2. PERMIT DRAWINGS ARE TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD AND TENANT PRIOR TO COMMENCEMENT OF WORK. PROVIDE WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. IN CASE OF CONFLICT WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES ARE TO GOVERN. NOTIFY ARCHITECT OF CONFLICTS. OBTAIN PERMITS AND APPROVALS REQUIRED. WORK IS GOVERNED BY CONDITIONS AS INDICATED IN CONTRACT DRAWINGS AND SPECIFICATIONS. G. DRAWINGS AND SPECIFICATIONS: STRUCTURAL, PLUMBING MECHANICAL, ELECTRICAL, FIRE PROTECTION, AUDIO VISUAL AND CABLING DRAWINGS ARE SUPPLEMENTARY TO THESE DRAWINGS. NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR SPECIFICATIONS IS TO BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE OWNER, TENANT, OR ARCHITECT. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES. DEVIATIONS FROM DIMENSIONED LOCATIONS REQUIRE ARCHITECT APPROVAL. DIMENSIONS ARE TYPICALLY TO THE CENTERLINE OF COLUMNS AND FINISHED FACE OF PARTITIONS, UNO. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE 6 FROM THE FACE OF THE ADJACENT PARTITION. 9. B/5 INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD. 10. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, ADVISE ARCHITECT WITHIN TEN ( 1 0) DAYS OF RECEIPT OF THE PLANS 50 ALTERNATE SELECTIONS MAY BE MADE. 1 I . "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLAN. OFFSET STUDS WHERE REQUIRED TO ASSURE FLUSH WALLS AT COLUMNS. 12. PROVIDE 3 SETS OF SUBMITTALS TO ARCHITECT; ONE FOR ARCHITECT ONE FOR GENERAL CONTRACTOR AND ONE FOR TRADE. 13. LEVEL EXISTING CONCRETE FLOOR SLAB AS REQUIRED FOR INSTALLATION OF PARTITIONS, DOORS, EQUIPMENT AND FLOOR COVERINGS. 14. MATERIALS USED IN CONSTRUCTION ARE TO MEET CURRENT FLAME CODE REGULATIONS. 15. MATERIALS: MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT ARE TO BE APPLIED A5 RECOMMENDED BY MANUFACTURERS. LIKE MATERIALS USED ARE TO BE OF THE SAME MANUFACTURER AND QUALITY UNO. 16. REPAIR DAMAGE TO ADJACENT WORK AT CONTRACTOR'S EXPENSE. 17. COORDINATION: VERIFY AND COORDINATE THE WORK OF TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS AND FOR CORE DRILLS AND OTHER SLAB WORK. 18. INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO BEGINNING THE WORK. 19. LAY OUT THE WORK TO CONFORM TO THE REQUIREMENTS OF CONTRACT DOCUMENTS. ESTABLISH AND MAINTAIN LINES AND DIMENSIONS. BEFORE DOING THE WORK, VERIFY MEASUREMENTS AND CONDITIONS AT THE 5ITE AND NOTIFY THE ARCHITECTS OF DISCREPANCIES. 20. NOTIFY ARCHITECT IF INFORMATION IN THE DRAWINGS ARE INCOMPLETE OR IN CONFLICT FOR CLARIFICATION. 2 I . PENETRATIONS FOR ELEC /MECh /COMMUNICATON PIPING ARE TO BE FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING AND FIRE CODES. 22. PENETRATIONS OF PIPING THROUGH THE DEMISING WALL ARE TO BE SURROUNDED BY THE WIRE MESH IN THE WALL AS CLOSELY AS POSSIBLE. 23. PENETRATIONS OF DUCTS THROUGH THE DEMISING WALL THAT ARE LARGER THAN 96 SQUARE INCHES ARE TO HAVE WIRE MESH INSIDE THE DUCT OPENING AT THE DEMISING WALL LOCATION; MESH TO BE 13 GA EXPANDED METAL. 24. VERIFY REQUIREMENTS OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES. PROVIDE ROUGH -IN CONNECTIONS. SEE DIVISION 26 - ELECTRICAL, NOTE 20 FOR FURNITURE ELECTRICAL INFORMATION. 25. FIRE -STOP PENETRATIONS WITH APPROVED THROUGH PENETRATION FIRE STOP ASSEMBLIES. FIRE STOP RATING TO CORRESPOND WITH RATING OF ASSEMBLIES AS REQUIRED PER CODE. 26. SPRINKLER, HVAC, MECHANICAL, AND ELECTRICAL ARE UNDER SEPARATE PERMIT. ELECTRICAL AND MECHANICAL SUBCONTRACTORS ARE TO OBTAIN APPLICABLE PERMITS AND COMPLY WITH APPLICABLE CODES. VERIFY REQUIREMENTS OF BUILDING SHELL STANDARDS AND TENANT REQUIREMENTS. SHOP DRAWING REVIEW OF THESE TRADES 15 FOR AESTHETIC PURPOSE. 27. PROVIDE FIRE/EMERGENCY SYSTEMS AS REQUIRED BY APPLICABLE CODES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT STROBES, AND SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 01 14 00 - WORK RESTRICTIONS I . VERIFY CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES WITH BUILDING MANAGER. VERIFY BUILDING CONSTRUCTION RULES WITH BUILDING MANAGEMENT. 2. MAINTAIN A CLEAR AND UNOBSTRUCTED PATH TO EXITS. 3. PROVIDE BACKGROUND CHECKS, WITH RESULTS ACCEPTABLE TO FPS, ON PERSONNEL THAT ARE WORKING ON THIS PROJECT. 01 25 00 - SUBSTITUTION PROCEDURES 1. SUBMIT MATERIAL SUBSTITUTIONS TO ARCHITECT DURING BID PROCESS. 0I 64 00 - OWNER - FURNISHED PRODUCTS 1. CONFIRM TENANT SUPPLIED ITEMS AND SYSTEMS WITH TENANT INCLUDING, BUT NOT LIMITED TO, DATA CABLING, AND EQUIPMENT. 2. TENANT'S CONTRACTOR WILL PROVIDE DATA CABLING, JACKS AND FACEPLATES. 01 7 123 - ACCEPTANCE OF CONDITIONS I VISIT JOB SITE AND VERIFY FIELD DIMENSIONS AND CONDITIONS AND NOTIFY ARCHITECT OF DISCREPANCIES BEFORE PROCEEDING WITH WORK. 01 7400 - CLEANING AND WASTE MANAGEMENT I . MAINTAIN THE WORKSPACE IN A CLEAN AND WORKMAN -LIKE MANNER. REMOVE WASTE REGULARLY AND DISPOSE INTO CONSTRUCTION PROVIDED RECEPTACLES. CONT. 01 78 00 CLOSEOUT SUBMITTALS 0I 78 00 - CLOSEOUT SUBMITTALS I . PROVIDE 2 COPIES OF OPERATION MANUAL FOR MATERIALS AND SYSTEMS TO BUILDING MANAGER PRIOR TO FINAL PAYMENT. CONFIRM REQUIREMENTS WITH BUILDING MANAGER. DIVISION 02 - EXISTING CONDITIONS I EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORK. 2. REFER TO SHELL AND CORE RECORD DOCUMENTS FOR INFORMATION RELATED TO CORE CONSTRUCTION FEATURES. I.E., STAIRWELLS, SHOWERS AND JANITOR/ELECTRICAL ROOMS. VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. PREPARE LOCATIONS TO RECEIVE NEW FLOOR FINISH AS REQUIRED. LEAVE FLOOR FLUSH. 21 4 100 DEMOLITION I . COMPLY WITH RULES AND REGULATIONS OF GOVERNMENTAL AUTHORITIES HAVING JURISDICTION OVER DEMOLITION WORK. SURVEY THE SITE OF PROPOSED WORK TO DETERMINE THE EXTENT AND NATURE OF THE DEMOLITION WORK PRIOR TO SUBMITTING BID. SUBMIT PROPOSED METHODS AND OPERATION OF DEMOLITION TO OWNER FOR REVIEW PRIOR TO START OF WORK. INCLUDE, IN SCHEDULE, COORDINATION FOR SHUT -OFF, CAPPING AND CONTINUATION OF UTILITY SERVICES AS REQUIRED. COORDINATE WITH BUILDING MANAGEMENT FOR REGULATIONS INCLUDING, BUT NOT LIMITED TO, ELEVATOR USE, RB131511 REMOVAL, PROTECTION OF BASE BUILDING CONSTRUCTION AND WORK WHICH WILL AFFECT OTHER TENANTS OR OTHER PARTS OF THE BUILDING. PROVIDE NECESSARY SAFE - GUARDS, BARRIERS, TEMPORARY POWER, LIGHTING, FIRE PROTECTION, ETC., AS REQUIRED DURING DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, KEEPING THE STAIRWAYS AND EXITS UNOBSTRUCTED AND AVAILABLE FOR USE DURING DEMOLITION. 5. REUSE BUILDING MATERIALS SUCH AS, BUT NOT LIMITED TO, DOORS AND FRAMES, HARDWARE, ELECTRIC AND TELEPHONE RECEPTACLES, DIFFUSERS, SPEAKERS, EXIT SIGNS, LIGHT FIXTURES, MECHANICAL FIXTURES, AND PLUMBING FIXTURES WHERE POSSIBLE, UNLESS INDICATED OTHERWISE BY THE OWNER. PROTECT AREA AND NEW OR EXISTING MATERIALS AND FINISHES FROM DAMAGE FROM CONSTRUCTION, DUST, WATER, ETC. DAMAGE TO EXISTING MATERIALS, FINISHES, STRUCTURE AND EQUIPMENT IS TO BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE TENANT AND BUILDING OWNER. DISCONNECT POWER IN THE AREA OF WORK PRIOR TO COMMENCEMENT OF DEMOLITION AND PROVIDE TEMPORARY POWER AND LIGHTING FOR DEMOLITION. DISCONNECT ELECTRICAL ITEMS TO BE PERMANENTLY REMOVED AT THE CIRCUIT PANELS. FURNISH LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF DEMOLITION WORK, LEAVE AREA BROOM CLEAN. 9. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING IS TO BE REMOVED FROM TENANT SPACES BELOW. 10. DURING THE REMOVAL OF ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. I I . REMOVE OR RELOCATE EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION AS REQUIRED. 12. DAMAGED, ALTERED OR REWORKED AREAS ARE TO BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH 13. PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUS AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DIVISION 03 - CONCRETE NOT USED DIVISION 04 - MASONRY NOT USED DIVISION 05 - METALS NOT USED DIVISION 06 - WOOD, PLASTICS AND COMPOSITES 06 10 00 - ROUGH CARPENTRY I . ROUGH CARPENTRY 15 TO INCLUDE WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS NEEDED TO SUPPLEMENT STEEL STUD WALLS. 06 20 00 - FINISH CARPENTRY I . FINISH CARPENTRY I5 TO INCLUDE INSTALLATION OF FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 06 22 00 - MILLWORK I . VERIFY CASEWORK DIMENSIONS IN FIELD. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS ARE TO BE FLUSH CONSTRUCTION. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UNO IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. PLASTIC LAMINATE: HIGH- PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UNO. LAMINATE IS TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. PROVIDE POST FORMED FRONT EDGES FOR HEAVY DUTY LOCATIONS. 7 OPEN CASEWORK IS TO BE PLASTIC LAMINATE ON EXPOSED SURFACES, UNO. APPLY MELAMINE TO INTERIOR OF CABINETRY WITH DOORS AND DRAWERS, UNO. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DIVISION 07 - THERMAL AND MOISTURE PROTECTION NOT USED DIVISION 08 OPENINGS I . EXIT DOORS ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT, AND EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 08 12 00 - METAL FRAMES I PROVIDE DOOR AND RELITE METAL FRAMES PER DRAWINGS. CONT. 08 14 00 WOOD DOORS 08 14 00 - WOOD DOORS I . PROVIDE SOLID CORE BUILDING STANDARD WOOD DOORS AT LEAST 1 3/4" THICK. 2. PRE- MACHINE DOORS FOR HARDWARE PER HARDWARE SCHEDULE. 3. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 4. REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION 15 PRESENT. 08 7 100 - DOOR HARDWARE 1. PROVIDE COMPLETE COMMERCIAL GRADE FINISH HARDWARE AND SUITABLE FASTENINGS FOR THE PROJECT. PROVIDE POWER AS REQUIRED TO SYSTEMS REQUIRING POWER. 2. MATCH B/5 STYLE, FINISH AND QUALITY AS SPECIFIED IN SIMILAR LOCATIONS. 3. HARDWARE FURNISHED IN THIS SECTION 15 TO COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES. ITEMS SPECIFIED IN THIS SECTION ARE TO BE FURNISHED BY A FACTORY DIRECT AUTHORIZED DISTRIBUTOR MAINTAINING LOCAL PARTS, STOCKS AND SERVICES FOR STANDARD SPECIFIED ITEMS. PROVIDE HARDWARE WHICH COMPLIES WITH WASHINGTON STATE AND LOCAL DISABILITY CODES, INCLUDING THE ANSI A 1 17.1 -2003 AND WASHINGTON STATE IBC SUPPLEMENTS CURRENTLY IN EFFECT. PROVIDE LEVER HANDLE LOCK SETS COMMERCIAL GRADE MORTISE -TYPE TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. PROVIDE ELECTRIC MORTISE LOCK DEVICES AT DOORS W/ CARD READER, DELAY PUSH TO EXIT FUNCTION AND PUSH TO ENTER FUNCTION. SPECIAL LOCKING HARDWARE (CIPHER, KEYCARD, ETC.) MUST COMPLY WITH FPA 10I , 5-2.1.6 AND BE OPERABLE WITH NO MORE THAN ONE RELEASING OPERATION FROM THE DIRECTION OF EGRESS. 7 PROVIDE HARDWARE INCLUDING ELECTRICAL POWER, BACKBOXES AND CONDUIT TO CEILING FOR CARD READER. THE TENANT'S VENDOR WILL MAKE THE CONNECTION TO THE EXISTING CARD READER SYSTEM. PROVIDE SEVEN -PIN RESTRICTED KEYWAY CYLINDER LOCKS ON OFFICE SUITE ENTRY DOORS. PROVIDE ELECTRIC TRANSFER BUTTS AND MAGNETIC SWITCH SETS ON DOORS HAVING AN ACCESS CONTROL SYSTEM READER AND AN ELECTRO- MECHANICAL LATCH OR LOCKSET. 10. 7' -0" HIGH DOORS ARE TO RECEIVE I -1/2 PAIR OF BUTTS, I I . DOORS ARE TO HAVE 3 SILENCERS, MIN. 12. SEE DIVISION 28, SECTION 28 13 00 FOR ELECTROMAGNETIC LOCK INFORMATION 13. EQUIP PERIMETER DOORS WITH AUTOMATIC DOOR CLOSERS AND LOCK - GUARDS (METAL PLATE ON OUTSIDE OF LOCKING MECHANISM TO PREVENT TAMPERING.) 14. EXIT DOORS ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE. 15. PROVIDE DOOR STOPS OF APPROPRIATE TYPE EXCEPT WHERE CLOSER LIMITS IMPACT WITH OBSTRUCTION. MATCH ADJACENT HARDWARE. 16. DOOR CLOSERS ARE TO BE ADJUSTED 50 THAT FROM AN OPEN POSITION OF 90 DEGREES THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES WILL BE 5 SECONDS, MINIMUM. 17. FIRE DOORS ARE TO HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 18. THE REQUIRED FORCE FOR PUSHING OR PULLING OPEN DOORS, OTHER THAN FIRE DOORS, 15 AS FOLLOWS: INTERIOR HINGED DOOR: 5.0 LB (22.2N) MAXIMUM SLIDING /FOLDING DOOR: 5.0 LB (22.2N) MAXIMUM EXTERIOR HINGED DOOR: 7.5 LB (22.2N) MAXIMUM. 19. LOCK SETS ARE TO CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. TAG KEYS WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 20. SUBMIT HARDWARE WITH CUT ShEET5 FOR ARCHITECT REVIEW. 2 I . SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 22. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND DOOR TO ENSURE PROPER OPERATION AND FUNCTION. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED. 23. EQUIP PERIMETER LOCKS WITH MANIMULATION - RESISTANT; LEVER OPERATED HIGH SECURITY LOCK SETS WITH INTEGRAL DEAD -BOLT LOCK. LOCKS ARE TO HAVE A MINIMUM OF A I -INCH THROW, AND ARE TO BE ENGINEERED 50 THE LEVER RETRACTS BOTH THE BOLT AND THE LATCH WITH A SINGLE LEVER ACTION FOR EMERGENCY EGRESS. CYLINDERS ARE TO BE BUILDING STANDARD. 24. INTERIOR LOCKS: PROVIDE BUILDING STANDARD LOCKS ON INTERIOR DOORS WHERE INDICATED. LOCKS ARE TO BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF ANY KEY, SPECIAL KNOWLEDGE OR EFFORT. 088010- GLAZING 1. GLASS I5 TO BE CLEAR TEMPERED SAFETY GLASS, UNO. SEE FINISH PLAN * DOOR SCHEDULE. 2. GLASS AT SIDELIGHTS AND DOORS I5 TO BE 1/4" TEMPERED SAFETY GLAZING, UNO 3. VERIFY THAT GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. THIS PROJECT CONTAINS GLAZING THAT I5 SUBJECT TO ADHERENCE TO FEDERAL GLAZING STANDARDS. ADVISE ARCHITECT IF INFORMATION IN THE DOCUMENTS 15 NOT IN COMPLIANCE WITH THE STANDARD BEFORE PROCEEDING WITH THE WORK. DIVISION 09 - FINISHES 1. APPLY FINISHES IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 2. SUBMIT SAMPLES OF FINISH COLORS SPECIFIED TO ARCHITECT FOR APPROVAL PRIOR TO BEGINNING WORK. CONFIRM DELIVERY TIMES AND BRING EXCESS LEAD TIMES TO ARCHITECT'S ATTENTION IMMEDIATELY TO ALLOW FOR RE- SPECIFICATION IF NECESSARY. FOLLOW MANUFACTURER PROVIDED DETAILED INSTALLATION GUIDELINES AND USE MANUFACTURER RECOMMENDED ADHESIVE PRODUCT AND TOOLS AS REQUIRED. PROVIDE TENANT /OWNER WITH MANUFACTURER RECOMMENDED CARE AND MAINTENANCE INSTRUCTIONS. 09 29 00 - GYPSUM BOARD 1. EXPOSED GWB EDGES ARE TO HAVE METAL EDGE RIM. 2. GWB LEVEL 4 * 5 PARTITIONS ARE TO BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. SURFACES ARE TO BE ALIGNED AND SANDED SMOOTH. OFFSET STUDS WHERE REQUIRED TO ALIGN FINISHED WALL SURFACE. WORK I5 TO BE PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. STABILIZE CONSTRUCTION AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE INTERNATIONAL BUILDING CODE. MAX. DISTANCE ACCEPTABLE FOR BRACES I5 TO BE 12' -0 ". CONT. 09 29 00 GYPSUM BOARD 5. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF PARTITIONS. "WALL SURFACES" MEAN VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 7 PARTITION HEADS ARE TO MATCH BUILDING STANDARD, UNO. 8. INDEPENDENTLY SUPPORT WALLS AND CEILINGS FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 9. PROVIDE FIRE TREATED WOOD OR EQUIVALENT SHEET METAL BLOCKING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. 10. FURR AND FINISH PIPES, CONDUITS, VENTS, ETC. UNLESS NOTED AS EXPOSED ON CONSTRUCTION DRAWINGS. I 1. INSULATION MATERIALS, INCLUDING FACINGS SUCH AS VAPOR BARRIERS OR BREATHE PAPERS INSTALLED WITHIN FLOOR- CEILING ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS ARE TO HAVE A FLAME - SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH I.B.C. STANDARDS. 12. PROVIDE A MINIMUM SOUND TRANSMISSION COEFFICIENT (STC) OF 45 AT OFFICE WALLS, AND 45 AT PERIMETER, CONFERENCE AND BREAKROOM WALLS. 13. FRAMING STUDS: PROVIDE GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE SHEET METAL BACKING WITHIN' WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK WHERE APPLICABLE. 14. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 15. PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 16. DRYWALL I5 TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT TOILET ROOMS AND BEHIND CERAMIC TILES, UNO. 17. INSTALL CORNER BEADS AT EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 18. PRIOR TO RECEIVING FINISH, PROPERLY PREPARED SURFACES AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 19. EXTEND SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 20. USE ACOUSTICAL SEALANT AROUND PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PROTECT PENETRATIONS OF FIRE -RATED WALLS BY APPLICABLE FIRE -RATED ASSEMBLIES. 09 51 00 - ACOUSTICAL CEILINGS I CEILING HEIGHTS, WHERE INDICATED, ARE FROM CONCRETE FLOOR DECK TO BOTTOM OF CEILING GRID OR OTHER FINISH SURFACE. 2. PROVIDE NEW CEILING TILE, CEILING GRID AND ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 3. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 4. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND TENANT CONTRACTORS SUCH AS THE TELEPHONE AND DATA CABLE COMPANIES. PROVIDE AN ADEQUATE PERIOD OF TIME, TWO TO FOUR DAYS, FOR TENANT'S VENDOR TO COMPLETE CABLING ROUGH -IN PRIOR TO INSTALLING CEILING GRID OR TILE. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. CUTOUTS ARE TO BE CENTERED WITHIN ACOUSTIC CEILING. TILE, UNO. 7 PROVIDE CLASS I FLAME SPREAD RATING AND INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 8. JOINTS IN THE TILE FIELD ARE TO BE SQUARE, LEVEL AND ALIGNED. 9. INSTALLED SUSPENDED CEILINGS LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 10. IN AREAS OF ALTERATIONS MATCH CONDITIONS AND ALIGN, LEVEL AND MATCH NEW CEILING TO OLD, AS POSSIBLE. REVIEW CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF DISCONTINUITIES IN THE CEILING WITHIN I0 DAYS. 09 65 00 - RESILIENT FLOORING I . INSTALL BASE IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 1 2". JOINTS ARE TO BE 6" OR GREATER FROM OUTSIDE CORNERS. 2. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1 /4" OVER 10'. 09 68 00 - CARPETING I PREPARE SUB FLOOR WITH LIGHT- WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 2. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW FOR BROADLOOM CARPET. 3. PROVIDE RUBBER REDUCER STRIPS AT LOCATIONS WHERE CARPET AND OTHER FLOORING MEET PER DETAILS. PROVIDE COLOR SAMPLES FOR APPROVAL. LOCATE INTERSECTIONS OF FLOOR FINISH MATERIALS AT DOORS DIRECTLY UNDER CENTER OF DOOR, UNO. FLOOR COVERINGS IN CLOSETS ARE TO BE THE SAME AS THAT OF THE SPACE INTO WHICH THE CLOSET DOOR OPENS, UNO. PRIOR TO INSTALLATION OF FLOOR FINISHES, PREP AND FLOAT EXISTING SUB -FLOOR TO PREVENT NOTICEABLE LUMPS OR DEPRESSIONS IN FINISHES, AND TO FINISH MANUFACTURER'S RECOMMENDATIONS TO ENSURE MANUFACTURER WARRANTY OF FINISH MATERIAL. 09 9 100 - PAINTING I . APPLY PAINT AND OTHER INTERIOR FINISHING AFTER PROPER PREPARATION TO ENSURE QUALITY AND APPEARANCE OF WORK. 2. UNLESS OTHERWISE NOTED, PRIME GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF SCHEDULED. FAINTED WOODWORK I5 TO BE FINISHED WITH ONE (I) COAT PRIMER AND TWO (2) FINISH COATS. - REVIEWED FOR CODE • PLIANCE APPROVED MY 12 2010 City of Tukwila BUILDING DIVISION SEALED WOODWORK I5 TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH 5 COMMERCIAL GRADE CLEAR SATIN VARNISH. 5. LIGHT COLORED PAINT I5 TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. G. DARK COLORED PAINT I5 TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 7. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. CITYLA APR 2 8 2010 PERMIT CE 5714 REGISTERED ITECT COLLEEN HAZELRIGS STATE OF WASHINGTON a 0 0. 0 N 0 G) REVIEW COMMENTS s U 0 PERMIT COMMENTS, FIN REVS s U 0 CV 4 w z m 0 UF- W0 cow oa z � 00 W 20 _ z o 01.= °017) ZOOLLW a' O 1-, QW® L . J OQs oww<s< 00.‹ w J 1- z 0 0 0 w 0 0) w 0 a a w 0 SABEY CORPORATION a CC 0 Checked by Chh Drawn by Ch1, SGB Scale AS NOTED Date 3/9/ I 0 Job No. 09:007 SHEET NUMBER IA -0.1 C) 201011AD CONT. SECTION 09 91 00 - PAINTING 8. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 9. WERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY ARE TO RECEIVE THE SAME FINISH AS THE ROOM, UNO. 10. PREPARED PAINTED SURFACES IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). I I . PUTTY NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 12. SAND WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 13. SAND ENAMELED FINISHES APPLIED TO. WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 14. FINISH WORK IS TO BE UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS ARE TO BE SHARP AND CLEAN WITHOUT OVERLAPPING. DIVISION I 0 - SPECIALTIES NOT USED DIVISION I I - EQUIPMENT NOT USED DIVISION I2 FURNISHINGS 12 2 100 - WINDOW BLINDS I . BUILDING OWNER PROVIDES BLINDS AT EXTERIOR WINDOWS. 2. CLEAN TO LIKE -NEW CONDITION AND BAG EXISTING MINI BLINDS. 3. PROVIDE SAMPLE AND CUT SHEET OF BLINDS TO ARCHITECT FOR REVIEW. DIVISION 13 - SPECIAL CONSTRUCTION NOT USED DIVISION 14 - CONVEYING EQUIPMENT NOT USED DIVISION 15 -20 - RESERVED FOR FUTURE EXPANSION DIVISION 21 - FIRE SUPPRESSION I . REQUIRED SEMI- RECCESSED MRE EXTINGUISHER CABINETS ARE TO BE WHITE FACTORY FINISHED BAKED ENAMEL. 2. PROVIDE CLASS 2A FIRE EXTINGUISHERS 3. FIRE EXTINGUISHERS ARE TO BE BY UNDERWRITER'S LABORATORY 2A- I OBC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UNO. PROVIDE ONE FOR EVERY 6,000 SF AND WITHIN 75 TRAVEL FEET OF OCCUPIED AREAS PER PLANS. CONFIRM LOCATIONS OF FIRE EXTINGUISHERS WITH ARCHITECT. 21 13 00 - FIRE SUPPRESSION SPRINKLER SYSTEM I . FIRE -STOP PENtIRATIONS WITH APPROVED THROUGH PENETRATION FIRE STOP ASSEMBLIES. MRE STOP RATING TO CORRESPOND WITH RATING OF ASSEMBLIES AS REQUIRED PER CODE. 2. SPRINKLER HEADS WITHOUT DIMENSIONS ARE TO BE CENTERED IN TILE OR COORDINATED WITH CEILING ITEMS UNLESS LANDLORD ALLOWS OTHERWISE. 3. PROVIDE WHITE STROBES ON THE CEILING WHERE REQUIRED. ARCHITECT I5 TO REVIEW AND APPROVE LOCATIONS. PROVIDE CLASS 2A MRE EXTINGUISHERS FOR EVERY 6,000 SF AND WITHIN 75 TRAVEL FEET OF OCCUPIED AREAS PER PLANS. CONFIRM LOCATIONS OF FIRE EXTINGUISHERS WITH ARCHITECT. CENTER SPRINKLER HEADS IN ACOUSTICAL CEILING TILE, UNO. DIVISION 22 - PLUMBING I PROVIDE ADEQUATE WALL THICKNESS FOR PLUMBING REGARDLESS OF WALL TYPE INDICATED. 2. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. WHERE IT APPLIES TO THE PROJECT. 3. FIXTURE INSTALLATIONS ARE TO CONFORM TO ACCESSIBILITY CODES. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS WHERE IT APPLIES TO THE PROJECT. 5. NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. PROVIDE GARBAGE DISPOSAL AT BREAK ROOM SINK. / i \ DIVISION 23 HEATING, VENTILATING AND AIR-CONDITIONING 23 30 00 -HVAC AIR DISTRIBUTION I . PROVIDE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF VAV BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY ARCHITECT PRIOR TO INSTALLATION TO INSURE FIELD REVISIONS WILL NOT BE REQUIRED. 2. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH MATERIALS, LABOR AND - ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR I5 TO BALANCE HVAC SYSTEM AS REQUIRED. SUBMIT LAYOUT OF HVAC ITEMS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 23 40 00 HVAC AIR CLEANING DEVICES I. PROVIDE FILTERS IN HVAC SUPPLY AND RETURN DURING CONSTRUCTION. REPLACE WITH NEW FILTERS PRIOR TO SUBSTANTIAL COMPLETION. DIVISION 24 - RESERVED FOR FUTURE EXPANSION DIVISION 25 - INTEGRATED AUTOMATION NOT USED DIVISION 26 - ELECTRICAL 2. ARCHITECTURAL DRAWINGS INDICATE LOCATION OF DEVICES SHOWN. SWITCHING AND CIRCUITING ARE INDICATED ON SEPARATE ELECTRICAL ENGINEERING OR AS -BUILT DRAWINGS AND ARE TO MEET BUILDING GUIDELINES. LOCATE OUTLETS AND MUD RINGS AT 18" AFT TO THE CENTERLINE, UNO. DRAWINGS INDICATE EXCEPTIONS TO THE STANDARD DIMENSION TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. 5ET OUTLETS SHOWN GROUPED TOGETHER ON PLAN TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. THE CENTERLINE OF ELECTRICAL OUTLETS ARE TO BE 6" FROM THE CENTERLINE OF PHONE/DATA OUTLETS WHERE LOCATED TOGETHER. WALL MOUNTED RECEPTACLES LOCATED IN CASEWORK ARE TO BE MOUNTED HORIZONTALLY. 7. SPECIAL OUTLET HEIGHTS ARE NOTED ADJACENT TO THE OUTLET. 8. GANG DEVICES WHERE MULTIPLE DEVICES OCCUR IN A SINGLE LOCATION, UNO. 9. DO NOT INSTALL OUTLETS BACK-TO-BACK. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL. CONT. DIV 26 - ELECTRICAL 10. LOCATION OF WALL MOUNTED POWER AND DATA DEVICES ARE TO BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 1 I . ELECTRICAL ENGINEER IS TO PROVIDE DESIGN/BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 12. ARCHITECT'S DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 3. COORDINATE POWER/DATA, FIRE SAFETY DEVICES * LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES CASEWORK. 14. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 15. PROVIDE UNDERWRITERS LABORATORIES, INC (UL) LABELED DEVICES THROUGHOUT. 16. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND TYPE (ARCHITECT 15 TO VERIFY WITH ENGINEER) OF OUTLETS AND TAKE PRECEDENCE OVER OTHER DRAWINGS UNO. ELECTRICAL ENGINEER'S POWER PLAN GOVERNS THE WIRING LAYOUT AND INSTALLATION IN WITH LAWS APPLICABLE AND ENFORCED BY GOVERNING AUTHORITIES. 17. PRIOR TO INSTALLING LIGHT FIXTURES ON THIS PROJECT, FIELD CHECK FOR CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. NOTIFY ARCHITECT OF CONFLICT(S) 50 A NEW LAYOUT CAN BE GENERATED. DO NOT INSTALL LIGHT FIXTURES UNTIL CONFLICTS ARE RESOLVED. 18. PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. 19. PROVIDE WHITE ELECTRICAL, MECHANICAL, FIRE PROTECTION AND OTHER COVER PLATES. COORDINATE LOCATION, STACKED TOGETHER AND WITH ARCHITECT AND LANDLORD REVIEW. 20. COORDINATE WORK RELATED TO EQUIPMENT WITH MANUFACTURER'S RECOMMENDATIONS, SPECIFICATIONS AND INSTRUCTIONS. 2 I . COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. AN ELECTRICIAN 15 REQUIRED TO CONNECT THE FURNITURE SYSTEM POWER HARNESS TO THE FURNITURE PANEL AND CONNECT THE POWER BETWEEN PANELS. COORDINATE WITH FURNITURE VENDOR FOR NUMBER OF CIRCUITS AND AMPS FOR EACH WORKSTATION. 22. COORDINATE WITH THE TENANT SUPPLIED FURNITURE SYSTEMS ITEMS SUCH AS ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS, LOCATIONS AS SHOWN IN THE DRAWINGS. 23. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 24. PROVIDE WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. 25. ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK ARE TO BE ON A GROUND FAULT INTERRUPTER DEVICE. 26. WIRING DEVICES ARE TO BE BUILDING STANDARD EXCEPT: - "ISOLATED GROUND" OUTLETS ARE TO BE ORANGE, - "HOSPITAL GRADE ISOLATED GROUND" OUTLETS ARE TO BE ORANGE WITH A GREEN DOT, - "EMERGENCY" OUTLETS ARE TO BE RED, AND - "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES ARE TO BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). COVER PLATES ARE TO BE BUILDING STANDARD FINISH, UNO. VERIFY WITH BUILDING MANAGEMENT. 27. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 28. CONCEAL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA IS TO BE PROVIDED BY TENANT. 29. PROVIDE ELECTRICAL, TELEPHONE, AND DATA OUTLETS PER NFPA STANDARD 70 OR LOCAL CODE, WHICHEVER I5 MORE STRINGENT. PROVIDE CONDUIT WITH PULL STRING TO DATA OUTLETS. SEE SECTION 0 164 00 NOTE 2 FOR TENANT FURNISHED ITEMS REGARDING CABLING. 30. ELECTRICAL OUTLETS ARE TO MEET NATIONAL ELECTRIC CODE (NEC) COMMERCIAL GRADE REQUIREMENTS FPR 20 AMP CIRCUITS UNO. LIMIT CIRCUITS TO SIX OR EIGHT OUTLETS TO AVOID OVERLOAD. 3 I . GROUND WIRE USED FOR CHASSIS GROUND MUST BE #1 0 AWG OR LARGER, STRANDED COPPER WIRE FROM GROUND BAR IN TELEPHONE ROOM TO NEAREST BUILDING GROUND. 32. GROUND WIRE USED FOR SINGLE POINT GROUND MUST CONFORM TO LOCAL BUILDING CODES. 33. GROUND WIRE USED FOR POWER SURGE PROTECTOR GROUNDING MUST COMPLY WITH SPECIFICATIONS OF THE PROTECTIVE DEVICE MANUFACTURER. 34. PROVIDE CABLE TRAY ABOVE THE CEILING FOR ACCESS TO OUTLETS AND FURNITURE; EXTEND TO THE EXISTING CABLE TRAY IN THE ADJACENT SHELL SPACE WHICH LEADS TO THE CORRIDOR. SEE PLANS FOR LOCATION. 26 50 00 - LIGHTING I . MOUNT SWITCHES AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. GANG MULTIPLE SWITCHES WHERE THEY OCCUR IN A SINGLE LOCATION, UNO. 3. RE- CIRCUIT AND RE- SWITCH ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW SWITCHES AS NEEDED. 4. LIGHTING 15 TO MAINTAIN 50 AVERAGE FOOTCANDLES AT WORKING SURFACES AT WORKING HEIGHTS (30 INCHES AFF), 20 FOOT CANDLES AT HALLWAYS AND LOBBY, AND 35 FOOTCANDLES AT CONFERENCE ROOMS. EQUIP EACH AREA WITH OCCUPANCY SENSORS, AND PER CODE. DIVISION 27 - COMMUNICATIONS 27 20 00 VOICE AND DATA COMMUNICATIONS I . VOICE/DATA SPECIFICATIONS ARE PER ICE -OCIO VENDOR. 2. FOR WORKSTATION FURNITURE: PROVIDE SEPARATE DATA, TELEPHONE, AND ELECTRICAL JUNCTION BOXES FOR THE BASE FEED CONNECTIONS TO USG- PROVIDED MODULAR OR SYSTEMS FURNITURE WHEN SUCH FEEDS ARE SUPPLIED VIA WALLS OR FLOORS. DIVISION 28 - ELECTRONIC SAFETY AND SECURITY 28 13 00 - ACCESS CONTROL I . PROVIDE DOOR ACCESS CONTROL PER PLANS. SEE DOOR HARDWARE SECTION FOR ADDITIONAL INFORMATION. 2. ELECTROMAGNETIC LOCKS ARE TO BE THE HEADER SURFACE MOUNT TYPE. FLUSH (SHEAR) LOCKS ARE NOT TO BE USED. THEY ARE TO HAVE A HOLDING FORCE CERTIFIED AT LEAST 1 500 POUNDS. SELECT MODELS W/ BUILT -IN SENSORS INDICATING DOOR CLOSED, LOCKED AND DOOR FORCED OPEN. STATUS READINGS ARE TO BE VIA THE ALARM CONTROL MONITORING EQUIPMENT OR THROUGH THE USE OF A SEPARATE ELECTRIC LOCK CONSOLE. ELECTROMAGNETIC LOCKS REQUIRE A REQUEST -TO -EXIT (RQE) PRESENCE (MICROWAVE OF PASSIVE INFRARED) SENSOR, RQE HEAVY DUTY BUTTON, OR RQE 'TOUCH SENSITIVE" BAR TO RELEASE THE LOCK IN ORDER TO EXIT, WHEN READERS OR KEYPADS ARE NOT USED ON BOTH SIDES OF THE CONTROL POINT. DOORS WITH PROXIMITY CARD READERS ARE TO BE EQUIPPED WITH DOOR CLOSERS, ELECTRIC STRIKES AND MORTISED STOREROOM FUNCTION DOOR HARDWARE. CONT. SECTION 28 13 00 ACCESS CONTROL 5. DOORS EQUIPPED WITH THIS SYSTEM ARE TO BE FAIL/SECURE. 6. PROVIDE A MINIMUM OF 15 PROGRAMMABLE PROXIMITY CARDS. 28 3 100 - MRE DETECTION AND ALARM I PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. 2. PROVIDE WHITE STROBES ON THE CEILING WHERE REQUIRED. ARCHITECT I5 TO REVIEW AND APPROVE LOCATIONS. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. PROVIDE EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. SUBMIT LAYOUT OF ITEMS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. DIVISION 29 49 - NOT USED END OF SPECIFICATIONS REVIEWED FOB CODE COMPLIANCE APPROVED Mg 122010 City of Tukwila BUILDING DIVISION ttoqw(o5, CITY 0 LA APR 2 8.2010 PERMIT CE Y T R Phone: 206 - 957 -0611 0-W 5714 REGISTERED CHITECT COLLEEN HAZELRIGS STATE OF WASHINGTON U) z 0 w co m 0 z REVIEW COMMENTS s 0 PERMIT COMMENTS, FIN REVS 0 cV w Q z 0 W C W O °> 00 W Z Quo 20 z c� 01-W®� =�UQZ zl-cr zz Z201-Q L ° F-- J W D LLi CT< Lia (3111(1)<P)< ''^^ ��//�� 0 ® < V, T VJ w J 1- 1- z 0 0 CJ) z 0 0 LL 0 W 0 co SABEY CORPORATION Q ❑ 0 c cn 0 Checked by CI-11-1 Drawn by CHH, SGB Scale AS NOTED Date 3/9/ I 0 Job No. 09:007 SHEET NUMBER IA -0.2 20 1011AD 1 REM • 0 0 Pm- ■ AFF II 11354 K4 maim= mg rell Eill11111111 111111rWIE*111111 //� III li " I ®� II�IIII% -a 111■t�• ee \ �,: -- : , 1.`111 ri 'u '3 3 ®156 1111--i3K 11'1■1 /AN■! 5 =' R • ■ 111■■■ 0 111 n _1IM C•7® ■ 11 ■ I I Mani _ ■IJ■ 1 355') ��O 1■ ■11 ■iu %r ■ ®- ®11il ® ® ®►DI!IIII ® ®■ ® ®�' ■ MEI MI I 'I 357 11� N':'_"__ ! IJ ® 11 II e©1111as ii■11 ®iim wit Nom I p 1 358 U weal 11 uI 359' BM al i milmi 'I� 11] gIaz���■II1■ trammimAirommr■ apt IN 1 ■ems _11 I �� ®■ "Oil L /I�l '''� �'' _C07■ �'' %C07■ III ME ■� i■ WIMP/ME CTINEill I I 361 MIIFiI iii mos lummi 11 111 !__ii■ TELEPHC ELEC CORRIDOR REFLECTED CEILING PLAN RCP LEGEND • BIS "SECOND LOOK" ACOUSTICAL CEILING TILE AND ON B/5 2'x4' CEILING GRID NEW 2 -LAMP T -8 2'X2' OR 2'x4' FLUORESCENT LIGHT FIXTURE. LAMP COLOR 3500 K. I NEW 2 -LAMP T -5 2'X2' OR 2'x4' FLUORESCENT NIGHT LIGHT FIXTURE. MIA NEW 2 -LAMP T -8 2'X4' FLUORESCENT EMERGENCY ILLUMINATION W /BATTERY BACKUP FOR COMMON EGRESS PATHWAY ,, NE B/S T 51 $ NEW B/S TOGGLE SWITCH. 0 NEW B/S EXHAUST FAN. F - - - -i UNDER CABINET LIGHTING\ e 5/5 CFL WALL WASH FIXTURE REFLECTED CEILING PLAN KEYNOTES O HVAC ZONE 1 0 HVAC ZONE 2 ® HVAC ZONE 3 HVAC ZONE 4 0 HVAC ZONE 5 ® HVAC ZONE 6 O EXTEND CORRIDOR CEILING GRID AND TILE. ® SWITCH LIGHTS WITHIN 1 5' OF WINDOWS SEPARATELY PER NON RESIDENTIAL ENERGY CODE. O PROVIDE EXHAUST FAN DUCTED TO EXHAUST DUCTING TO PREVENT FOOD ODORS FROM CIRCULATING IN HVAC SYSTEM. l o PROVIDE HDMI /USB CONNECTION BOX FOR CEILING MOUNTED PROJECTOR CONNECTED TO FLOORBOX UNDER TABLE. A 1 1 PROVIDE EPSOM UNIVERSAL PROJECTOR MOUNT ELPMBPJF MOUNTED FROM CEILING SLAB. PROVIDE I 1/2" 0 STL PIPE AT LENGTH REQUIRED TO MOUNT PROJECTOR AT CEILING, THREADED 1" MIN BOTH ENDS. CONFIRM LOCATION WITH AV VENDOR. EPSOM EX -71 PROJECTOR PROVIDED BY OCIO. 12 PROVIDE CONTINUOUS UNDERCABINET LIGHTING FIXTURES, SWITCHED IN 4 - 4' SECTIONS AT THE FIXTURE FOR WORKSTATION CONTROL. 13 CENTER TEES E -W IN N OFFICES. 14 ALIGN E -W GRID ACROSS NORTH SIDE OF BUILDING. 0, CENTER LIGHTS IN HALL. 16 ALIGN N -5 GRID IN WEST OFFICES. 17 CENTER E -W GRIDS IN WEST OFFICES. 18 CENTER N -S GRID IN WORKROOM. 19 CENTER E -W GRID IN COPY AREA. 20 CENTER GRID IN ROOM. O. PROVIDE J -BOX ON CEILING SLAB WITH 4 FOOT FLEX CONNECTOR FOR PROJECTOR. 22 EXTEND EXISTING CABLE TRAY IN WEST SIDE OF BUILDING TO AND THROUGH THE SPACE AS SHOWN AND CLOSE TO EXISTING J -HOOKS WITH CABLING. CABLE WILL BE BROUGHT TO THE WIRING CLOSET BY CABLE VENDOR. D • OFFICE 355 OFFICE 357 ov OFFICE 359 Tr 0o OPEN WORK AREA 354 CONFERENCE 356 11D ENTRY 353 &e. TELEPHONE ELEC. 1 CORRIDOR 1 BREAK 358 +60" AFF OUTLETS @ TV /SMT BD dt X42" APP @ BR RM G I CASEWORK, TYPO el. u-VaT)=5 OFFICE 60 WORK ROOM 363 OFFICE 361 aDV OFFICE 362 +37" AFF @ WK RM CASEWORK, TYP. POWER /COMMUNICATION PLAN 1/8" = 1'_0" POWER /COMM. LEGEND 5/5 STD WALL - MOUNTED ELECTRICAL QUAD OUTLET. 0 B/5 STD WALL - MOUNTED ELECTRICAL DUPLEX OUTLET. ZI STD WALL- MOUNTED COMBINATION VOICE/DATA OUTLET. 1 BIS STD WALL - MOUNTED VOICE LINE OUTLET. la BIS STD WALL- MOUNTED CARD READER. FB FLOOR POWER OUTLET BOX C CABLE TV OUTLET 55 HDMI AND USB CONNECTION IN FLOOR BOX / I (USB) U5B PORT OUTLET JQ J -BOX NUMBER ADJACENT TO DATA OUTLET = QUANTITY OF OUTLET TYPE IF NO NUMBER INDICATED = I OUTLET THAT TYPE POWER /COMM. PLAN GENERAL NOTES I . TERMINATE PHONE IN EXISTING TELEPHONE ROOM. 2. TERMINATE DATA CABLES IN EXISTING COMPUTER ROOM TO EXISTING OR NEW TENANT PROVIDED EQUIPMENT TRACKS. 24 -HOUR COOLING NOT REQUIRED. USE TENANT CABLING STANDARDS AS IT PERTAINS TO CABLE TYPE SPECIFICATIONS AND GUIDELINES. SEE OUTLINE SPECS SECTION 27 20 00 FOR STANDARD REFERENCE. 3. PROVIDE STEEL CONDUITS WITH PULL STRING IN WALL TO VOICE/DATA OUTLETS. CONDUIT SIZE I " 0 UNO. POWER /COMM. PLAN KEYNOTES O 30 AMP DEDICATED OUTLET FOR COPIER Q PROVIDE TIMER AT OUTLET FOR COFFEE POT. O SEE ELEVATION 3a FOR POWER/COMMUNICATIONS THIS AREA. O PROVIDE I 1/2" 0 CONDUIT. PROVIDE 3" 0 CONDUIT. LIGHTING CALCULATION - OFFICE WATTAGE ALLOWED: 3,584SFx I.0 WATT PER 5F =3,584WATTS WATTAGE PROPOSED: 52 2'x4' LIGHT FIXTURES x 64 WATTS PER FIXTURE = 3,328 WATTS 2 2'X2' LIGHT FIXTURES X 40 WATTS PER FIXTURE = 80 WATTS 2 WALL WASH FIXTURES X 32 WATTS /FIXTURE = 64 WATTS TOTAL WATTAGE = 3,472 WATTS CONCLUSION: WATTAGE PROPOSED 15 LESS THAN WATTAGE ALLOWED. RCP GENERAL NOTES I . PROVIDE LOCAL THERMOSTAT FOR EACH HVAC ZONE. o- 2" 0 CONDUIT FOR DATA/COM UN ICATION WIRE k I" OWER CONDUIT CI 1 CABLE TV, DATA AND , POWER CENTERED IN ROOM l 0 USB CABLE TV, USB, HDMI / USB, DATA AND POWER BB 0 0 60" AFF 40" AFF CONF. RM. POWER /COMM ELEV 1/2" = I._0.. TYPE B. 2 DOOR ELEVATIONS I/4 I' -0" DOOR TYPES (SEE DOOR ELEVATIONS) A. NEW B/5 7' -0" HIGH x 3' -0" WIDE X 1 -3/4" TH SOLID CORE SLAB WOOD DOOR W/1'-6" W RELITE. VENEER: B/5 STAINED HARDWOOD. FRAME: 2" HM W/ WELDED CORNERS PAINTED TO MATCH ADJACENT WALLS. B. NEW B/S 7' -0" HIGH X 3' -0" WIDE X I -3/4" TH SOLID CORE WOOD DOOR. VENEER: B/S STAINED HARDWOOD. FRAME: 2" HOLLOW METAL WITH WELDED CORNERS PAINTED TO MATCH ADJACENT WALLS. E. EXISTING TO REMAIN. HARDWARE TYPES GENERAL NOTE: PROVIDE SILENCERS AND SOUND GASKETS AT DOOR FRAMES. a. B/S MORTISED LATCHSET (PASSAGE FUNCTION) B/5 HINGES AUTOMATIC CLOSER STOP WHERE REQUIRED AT 90 DEGREE WALL B/S MORTISED LATCHSET (PASSAGE FUNCTION) B/S HINGES STOP WHERE REQUIRED AT 90 DEGREE WALL c. 5/5 MORTISED LOCKSET (OFFICE FUNCTION) 5/5 HINGES STOP WHERE REQUIRED AT 90 DEGREE WALL B/S MORTISED LOCKSET (OFFICE FUNCTION) B/5 HINGES AUTOMATIC CLOSER STOP WHERE REQUIRED AT 90 DEGREE WALL e. EXISTING TO REMAIN. f. CARD READER ELECTRONIC STRIKE HINGES NON- REMOVEABLE (PEENED, PINNED, OR SPOT WELDED) AUTOMATIC CLOSER STOP KICK PLATE LOCK GUARD B/S MORTISED LOCKSET : MANIPULATION RESISTANT LEVER OPERATED HIGH SECURITY DEAD BOLT LOCK WITH MIN. I " THROW. LEVER 15 TO RETRACT BOTH BOLT AND LATCH WITH SINGLE ACTION FOR EMERGENCY EGRESS. CYLINDER 15 TO BE HIGH SECURITY. EGRESS SIDE 15 TO BE OPERABLE WITHOUT KEY, SPECIAL KNOWLEDGE, OR EFFORT. GLASS 1/4" TEMPERED THROUGHOUT EXCEPT FRONT ENTRY GLASS 15 TO BE WIRED SECURITY GLASS 18" AFF REVIEWED FOR CODE COMPLIANCE APPROVED Mid 12 2010 City of Tukwila BUILDING DIVISION 1 FLOOR PLAN 1/8 = I' -0 WALL LEGEND 0 EXISTING PARTITION TO REMAIN. B/5 TENANT INTERIOR PARTITION. SEE 9 /IA -2.1. 5/5 DEMISING PARTITION. SEE 5 /IA -2.1. B/S FULL HEIGHT RELITE. SEE DOOR ELEVATIONS. PARTITION TO BE DEMOLISHED. 5' 10' MINN IM 11111 MI la FLOOR PLAN GENERAL NOTES 20' I PROVIDE BACKING IN WALL FOR TV, WHITE BOARD, UPPER CABINETS, AND OTHER WALL - MOUNTED ITEMS. FLOOR PLAN KEYNOTES NORTH 30' O SEMI- RECESSED FIRE EXTINGUISHER CABINET. FACTORY FINISH WHITE, AND FIELD PAINTED TO MATCH ADJACENT WALL. PROVIDE FIRE EXTINGUISHER, TYPE PER CODE. ® REFRIGERATOR WITH ICE'MAKER PROVIDED BY TENANT. ® PROVIDE COLD WATER SUPPLY TO REFRIGERATOR. 0 MICROWAVE PROVIDED BY TENANT. • PROVIDE WATER HEATER, LOCATION SPECIFIED BY DESIGN -BUILD MECHANICAL CONTRACTOR. • DEMO EXISTING DEMISING WALL. O REMOVE FIRE EXTINGUISHER. O WRAP COLUMN WITH STEEL STUDS AND 5/8" GWB IN SAME CONFIGURATION AS COLUMN IN OFFICE 355. O ENCLOSE 4" SQUARE STEEL COLUMN IN WALL. to PROVIDE 5/8" GWB OVER EXISTING PERIMETER FRAMING UP TO EXISTING GEILING HEIGHT STRIP OF GWB THROUGHOUT. INSTALL BATT INSULATION TO MATCH WHERE MISSING. WHITEBOARDS PROVIDED BY OCIO. SMART BOARD BY OCIO. FLAT SCREEN TV BY 000. 14 WRAP COLUMN WITH STEEL STUDS AND 5/8" GWB IN SAME CONFIGURATION AS COLUMN IN OFFICE 355 EXCEPT THE WEST SIDE. WEST SIDE FINISHED FACE MUST BE NO MORE THAN 4 INCHES FROM THE COLUMN FOR DOOR ASSEMBLY TO FIT. R CITY APR 2 8 2010 PERMIT CEN 5714 REGISTERED CHITECT COLLEEN HAZELRIGS STATE OF WASHINGTON U) C w c 0 0. 0 0 0 m 0 as 0 REVIEW COMMENTS O 0 N w z O CC I— LLI W '7 O z cc8 01 —®rn zu-p�a z ~CC8z` Qzp_� W W��? Qq:o: 0_ OW <8< O❑QC/)I —U) Z� WQ O Z Z 0 J W Z < 0 U D W W ®2i ®O W LL. U CC APPROVED: 0 cc 0 m 0 w m C Q ❑ CIS GROUP Checked by CH H Drawn by CHH, 5GB Scale AS NOTED Date 3/9/10 Job No. 09:007 SHEET NUMBER IA -1.1 © 20I011AD FINISH SCHEDULE SYMBOL DESCRIPTION MANUFACTURER STYLE COLOR/FINISH INSTALLATION SIZE CONTACT NO-1 t5 - CARPET TRANSITION JOHNSONITE CTA -XX -XX 129 -SILK PER MFR INSTRUCTION TBD TBD CARPET TO RESILIENT FLOORING LINOLEUM TILE FORDO DUAL 3 13 �` M A RTHA KORSLUND 1 LT ( -I MARMOLEUM CALICO GLUE DOWN 13" X 13" 206- 650 -0597 NOTE 2, 8 LINOLEUM TILE FORDO MARMOLEUM DUAL 13621 0 CLUE DOWN 1 3" X 131 MARTHA KORSLUND ACCENT, NOTE 2, 8 1 LT 2 1 DOVE GRAY 206- 650 -0597 BlOBASED TILE ARMSTRONG MIGRATIONS T35 12 SANDY BEIGE GLUE DOWN 12" X 12" X 1/8" KIN SHRADER 800- 356 -930 I X 8975 FIELD TILE, NOTE 2 55T -1 BIOBASED TILE ARMSTRONG MIGRATIONS T3509 MUSHROOM BEIGE A. GLUE DOWN 12" X 12" X I /8" KIM SHRADER 800 - 356 -930 I X 8975 ACCENT TILE, NOTE 2 513T-2 © CARPET TILES MANNINGTON COSTILLA -MOD 820G EXPEDITION GLUE DOWN 24' X 24" ROBERTA DILLON 206 -714 -4443 ". ' IC. - Rte!!' AL , i (SEE DIAGRAM BELOW), NOTE 7 CPT -1 PAINT BENJAMIN MOORE COLOR PREVIEW EA M /GGS ANNEHELL UI OCR- 92 MC�N MEDIUM NAP ROLLER N/A RAY S 800 642 5678 NDTESMAN NOTE 1 P 2 PAINT BENJAMIN MOORE CLASSIC COLORS 7 17 PARADISO MEDIUM NAP ROLLER N/A RANDY TESSMAN 800- 642 -5678 ACCENT, NOTE 1 RUBBER BASE JOHNSONITE RUBBER TIGhTLOCK (TDC -4 2') I A I \ GLUE ON 1/4 X 4 „ TRA SUPPLY COMPANY, INC. 206 -282 -31 10 WITH CPT -1 AND RESILIENT TILE, NOTE 2 B -I 4 SEA BREEZE 40 P -LAM WILSONART 7919 -78 AMBER CHERRY GLUE ON N/A HAZEL STRICKON 206- 321 -3294 VERTICAL SURFACES ® P -LAM WILSONART -hD 1838 -45 CRYSTALLINE DUNE GLUE ON N/A HAZEL STRICKON 206 - 321 -3294 COUNTERTOPS, POST - FORMED EDGES BL -1 BLINDS LEVOLOR HORIZONTAL TBD CONFIRM W /LANDLORD I INTERIOR RELITES BL -2 BLINDS LEVOLOR TILTONE HORIZONTAL TBD CONFIRM W /LANDLORD " EXTERIOR WINDOWS v CEILING TILE ARMSTRONG FINE FISSURED 1 824 WHITE (Wh) 2' X 4' BRIANNE DEVER 877- 276 -7876, OPTION 8, EXT 4325 SCORED TO SECOND LOOK FINISH NOTES: 1. PAINT COLOR 15 FOR MATCH 2. VINYL IS NOT AN ACCEPTABLE SUBSTITUTE. PROVIDE ALTERNATIVES TO VINYL IN THE PROJECT. CONSULT ARCHITECT. 3. ADHESIVES ARE TO BE LOW VOC. 4. FLOORS ARE TO RECEIVE CPT- I , UNO. 5. WALLS ARE TO RECEIVE P- 1 , UNO. 6. WALL BASE IS TO BE 5 -1, UNO. 7. PROVIDE I 0 % OVERAGE ON CARPET. 8. SEE FLOOR PATTERN. .. ^ BRICK ASHLAR INSTALLATION 0 Mw -J ism J1355 357 s Toi 358 • 363 Q6 L TELEPHC ELEC CORRIDOR 361 (oN\\ FURNITURE PLAN - FOR INFORMATION ONLY I /8" = 1' -0" RESILIENT FLOORING LEGEND • STARTING POINT FOR RESILIENT FLOORING PATTERN LT- I LT -2 RESILIENT FLOORING KEYNOTES 0 TILE EXTENDS INTO CABINET TOE -KICK. REVIEWED FOR CODE COMPLIANCE APPROVED ruti zoo City of Tukwila BUILDING DIVISION FINISH PLAN 1/8" = 1 ' - 0" STARTING POINT 0 0 Wit 10' 20' NORTH 30' • 7 1 • 1 1 1 • C3 II F 11 11 11 11 11 11 11 11 11 11 11 N 11 11 11 11 11 11 11 11 11 1 11 11 11 11 11 RESILIENT FLOORING PLAN RMS 358, 363 1/4" = 1' 0" bioft.hoc UMBRA APR 2 8 2010 PERMIT CEN y CD 0 5700 Corson Ave S Seattle, WA 98108 O O ti O CD N a) 0 0_ E U 2 0 L . N CB 5714 ISTERED HITECT COLLEEN HAZELRIGS STATE OF WASHINGTON 0 0., 0 u) a) 0 m 0 REVIEW COMMENTS s 0 W z tL z 0 0 1— w 0 0 N N w z 01— w 0 a z W Q ap 20 zcfl O1—w ®� =�Uaz z�p�a o zl —pCUzz hioM ®= 1 — OC w D uw o-V UW WNW 0®Q0), -co 0 z W z 7 w z w pC U L.J.. V, of) VJ H LLLLLL APPROVED: W Q 0 SABEY CORPORATION d 0 1 0 Checked by CI-111 Drawn by C1111, SGB Scale AS NOTED Date 3/9/ I 0 Job No. 09:007 SHEET NUMBER IA -1.2 © 2010 t1AD TITLE SCALE ♦ UNDERCABINET LIGHTING FIXTURES SWITCHED AT FIXTURE FOR EACH WORKSTATION. SEMI - CIRCLE POST FORM COUNTER NOSING. RETURN PLAM 4" FROM FRONT. COUNTER TOP 2 LAYERS OF 3/4" PLYWD. COUNTER SUPPORTS 2 LAYERS OF 3/4" PLYWD. CASEWORK DTL - WORKROOM 1 1/2" = I' - 0 30" 30" 30" 30" 3 TITLE SCALE 4� TITLE J SCALE I5 30" I 30" I 1 5" I 30" 0 0 1 ♦ • BREAK RM NORTH ELEVATION 1/2" = I - 0" 30" 30" 30" 30" O O O 000 60" X . TYP a 60" 000 60" C1 WORK RM SOUTH ELEVATION 1/2". ii_0" 1 60" SEE DETAIL 1/IA-2.1 FOR WALL BRACING. 5/8" GWB OVER 2 1/2" x 25 GA. METAL STUD @ 24" 0.C. FILLED WITH SOUND ATTENUATION BATT INSULATION. 2 1/2" X 25 GA STL STUD BOTTOM TRACK. FASTEN W /SHOT PIN IN PLASTIC WASHER (HILTI # DS 42 P 10, TYP. 2'OF4 "BATT INSULATION ON BOTH SIDES OF WALL SEE DETAIL 3/IA -2. I FOR ACT BRACING. CONSTRUCTION PER GA WP 1 073 OR 1076 TO ACHIEVE STC RATING OF 45 MIN. 9 PARTITION WALL ri O� TITLE SCALE 11 SCALE TITLE CABINET LOCK, TYP. KEY THE SAME THROUGHOUT THIS ROW OF CABINETS. 60" 00 00 60" 0 60" HOLD GWB AWAY FROM SLAB 1/2" CLG. GRID EDGE TRIM PER DETAIL 3/IA -2. I 5/8" GWB OVER 2 1/2" x 25 GA. METAL STUD @ 24" O.C. FILLED WITH SOUND ATTENUATION BATT INSULATION. CONT. 2 1/2" 20 GA SLIP JOINT TRACK W/ 2-# I O SCREWS AT 24" OC. 13 GA EXPANDED METAL MESH ON OUTSIDE OF SUITE AT DEMISING WALL. CONSTRUCTION PER GA WP 1 073 OR 1 076 TO ACHIEVE STC RATING OF 45 MIN. 2 I /2" X 25 GA STL STUD BOTTOM TRACK. FASTEN W /SHOT PIN IN PLASTIC WASHER HILTI #DS42 P10, TYP. 5� DEMISING WALL ) I/2" = I - 0" HM DOOR FRAME REVIEWED FOR CODE COMPLIANCE APPROVED MAY 12 2010 City of Tukwila BUILDING DIVISION DOOR PER SCHEDULE DOOR HEAD /JAMB DETAIL U3 =1 -a WALL PER PLAN GLASS PER DOOR TYPE HM DOOR FRAME DOOR PER SCHEDULE DOOR /RECITE JAMB DETAIL 3" = 1 ' 0" r 1 RECITE SILL i3 =1 0" p10- 03 CONCRETE-- METAL DECK ANGLE: 1 "X 1 "X 1 /2 " LONG X.10 THICK (TYP.) SHOT PIN W/ PLASTIC WASHER (HILT! #DS 42 P 10) (TYP.) #9 WIRE (TYP.) # 12 X 1/2" SCREW BACKING PLATE 2" X 2" X 18 G.A. LATERAL BRACING TENANT • C WALLS LATERAL BRACING PER DETAIL ABOVE (TYP.) NOTE: LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (PER TYP. PART. PLAN) TYPICAL PARTITION BRACING N.T.S. FASTEN' VERTICAL STRUT FROM MAIN RUNNER TO STRUCTURAL SUPPORT ABOVE HEAVY GAUGE WIRE "FIN". VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' -0" 0.C. OR NO. 10 GAUGE @ 5' -0' O.C. ALONG MAIN RUNNERS W/3 WIRE TURNS. INSTALL WITHIN I :G OUT OF PLUMB UNLESS COUNTER SLOPING WIRES ARE PROVIDED. 45° VERTICAL STRUT @ 12' -0" EACH DIRECTION AND G' -O" MAX FROM WALL, FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN CE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. 45° HEAVY DUTY MAIN RUNNER AT 4' -0" 0.0. — LATERAL BRACING: SPLAY WIRE ODS. SEE NOTE I . HEAVY DUTY CROSS RUNNER INSTALLATION INSTALL PER ASTM C 636, STANDARD PRACTICE FOR INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANELS SUSPENDED CEILING SUPPORT DATA. I LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" 0.0. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. 2. WIRE TIES TO HAVE 3 TIGHT TURNS WITHIN 3 ". 3. PROVIDE 2" MIN WIDTH PERIMETER SUPPORTING CLOSURE WALL ANGLE. 4. ATTACH GRID TO THE WALL ANGLE AT TWO ADJACENT SIDES, POP RIVETS ACCEPTABLE. AT OTHER SIDES PROVIDE 3/4" CLEAR BETWEEN END OF GRID AND WALL. 5. PROVIDE STABILIZER BAR TO PREVENT SPREAD OF MAIN BEAMS AND CROSS TEES. 6. PROVIDE PERIMETER SUPPORT (TAIL) WIRES WITHIN 8" OF WALL EDGES. PROVIDE SEISMIC JOINT TO LIMIT UNINTERRUPTED CEILING SYSTEMS TO 2,500 SF. PROVIDE POSITIVE BRACING AT CEILING PLANE CHANGES. SUPPORT CABLE TRAYS AND ELECTRICAL CONDUIT INDEPENDENTLY OF CEILING. 10. FOR CEILINGS WITHOUT RIGID BRACING PROVIDE 2" OVERSIZE RING, SLEEVE OR ADAPTOR THROUGH TILE TO ALLOW FREE MOVEMENT OF AT LEAST I " IN ALL HORIZONTAL DIRECTIONS, OR PROVIDE SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT PROVIDES THE I " HORIZONTAL MOVEMENT REQUIRED. SUSPENDED CL. SUPPORT DATA N.T.S. PROVIDE INSULATION AT SUPPLY* DRAIN LINES. ACCESSIBLE SINK AND FAUCET VERIFY THAT PLUMBING LINES AND FIXTURES FIT WITHIN ENCLOSURES PRIOR TO PLUMBING INSTALLATION 3/4 " PLYWOOD ♦ SUBSTRATE COUNTERTOP d- = W /SQUARE P -LAM FINISH = EDGES m 24" FALSE DRAWER ATTACHED TO FACE OF FACSIA, P -LAM CLAD STAPLE PULLS CONCEALED HINGES GARBAGE DISPOSAL AS SPECIFIED 3/4 " PLYWOOD DOOR SUBSTRATE W/P -LAM FINISH 1/4 " MDF BACK CLEAR AREA FOR R ACCESSIBILITY CITY APR 2 8 2010 PERMIT CENTER CASEWORK DETAIL - SINK 1" = - 0" Cinq Phone: 206 - 957 -0611 N O r Cr) 0 N x U- 5714 REGISTERED AR IHITECT COLLEEN HAZELRIGS STATE OF WASHINGTON z 0 (i) w cc 0 0 0 0) 0 0 REVIEW COMMENTS U 0 U) w z 1— z w 0 U v_ uJ s U O w z m O EE F W W Z 5 � J 0. m z Q o0 0 z co 0=W®( Z6cc cc z -06_11 z I-- pC U W ®a� z2U tin m -1I— J Oa..Qror UW <N< 0®QU)rU) z 0 0 cp z 0 W W (n cc � J Q 0 W I— to 0 w Q z rt--: 0 APPROVED: w 0 SABEY CORPORATION 0 0 can U Checked by CH H Drawn by CHH, SGB Scale AS NOTED Date 3/9/10 Job No. 09:007 SHEET NUMBER IA -2.1 0 20101-IAD