Loading...
HomeMy WebLinkAboutPermit D10-117 - WESTFIELD SOUTHCENTER MALL - GAS METER ALCOVEWESTFIELD MALL GAS METER ALCOVE 2800 SOUTHCENTER MALL D10 -117 City 61PTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: D10 -117 Issue Date: 06/25/2010 Permit Expires On: 12/22/2010 Tenant: Name: WESTFIELD MALL - GAS METER ALCOVE Address: 2800 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WY SW , SEATTLE WA 98106 Phone: 206 624 -2777 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Phone: 206 382 -3443 Contractor License No: BNBUII *990K3 Expiration Date: 09/12/2011 DESCRIPTION OF WORK: CONSTRUCTION OF AN EIGHT FOOT HIGH MANSONRY WALL AROUND FUTURE TENANT GAS METERS. Value of Construction: $50,000.00 Fees Collected: $1,583.80 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -7/07 D10 -117 Printed: 06 -25 -2010 City o? Tukwila O� r. De P artment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us • Permit Number: D10-117 Issue Date: 06/25/2010 Permit Expires On: 12/22/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Permit Center Authorized Signature: \� �j� �'l� Date: 6(4742 I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does notprre to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. authorized to sign and obtain this development permit. \ Signature: `l `" 111111111P Date: ' 25. j 0 Print Name: MAO- - A 1 L—t--t A t'1/3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -7/07 D10 -117 Printed: 06 -25 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW WESTFIELD MALL - GAS METER ALCOVE Permit Number: Status: Applied Date: Issue Date: D10 -117 ISSUED 05/05/2010 06/25/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official m a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 10: Masonry construction shall be special inspected. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the doc: Cond -10/06 D10 -117 Printed: 06 -25 -2010 • wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: hltp: / /www.ci.tukwila.wa.us Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Extend sprinkler protection to soffit above future gas meters and enclosure. 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 24: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. (INSTALL A KEYBOX AT THE ALCOVE GATE FOR FIRE DEPT. ACCESS.) 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 26: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 28: ** *PLANNING DIVISION CONDITIONS * ** doc: Cond -10/06 D10 -117 Printed: 06 -25 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: Irrigate at island. 30: Trees shall be a minimum 2 1/2" caliper. 31: Island shall include shrubs and groundcover. * *continued on next page ** doc: Cond -10/06 D10 -117 Printed: 06 -25 -2010 • 1 City of Tukwila Department of Community Development O 1 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: M A V L\ 1 t—t--1 A Date: • ZS . 10 doc: Cond -10/06 D10 -117 Printed: 06 -25 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: /www. ci. tuktitdln. wa. xs Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) A '1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Get King Co Assessor's Tax No.: 2(02 - a LI no I 0 Site Address: 2$oO Se> LAll•-te-eKat-- Tenant Name: W ES Tai Ll� Property Owners Name: IAA S l l iC-'C T -- Suite Number: 0/A- Floor: 1 New Tenant: ❑ Yes 'kr.. No Mailing Address: 2-S00 5•01X1f1'C -S- rtY- City 1,11(1s-- 931 e State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Whtr7t.JE ..So1-1-1 Mailing Address: 1c" i s /e "tL66 Ste/ E -Mail Address: l4PcY --l& 0- St 1 4 - .42>rt9 Day Telephone: 20 & • 62-'! • 2-f27 S }'f%LLs /.c/A- 93 /o City State Zip Fax Number: 20 (> • 6 2.41. 2-`/ 73 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: . L cif' T��zhn t r-1 tL� .4'r -71•11S Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - Alt' plans must be wet stamped by A chitect of Reco Company Name: S .1Y1 • ��-1 I -Pi' /.44- 1TT$•-'TT3 Mailing Address: Li 000 I €L P-t t)(, E 144 1.A..1 -Q1'a Spk'TTLE" i4A— 1 $ /t Ch City State Zip Contact Person: k ki-C - ..Sari' Day Telephone: 2 > • 61-41. 2»7 E -Mail Address: ItiiFE Yj 4f Q sivi S7'7-ntt • Fax Fax Number: 24)6 ' 62-41- 27 3 ENGINEER OF RECORD - Ali plans must be wet stamped by Engineer of Record Company Name: Mailing Address: /9sM Get ) *ewe) 22-ex-) S/ )(rile AYe X60/ S FA7i"L1. !- ko-- lee /z/ Contact Person: Pf//sJ/ V//v/A A"L-4 E -Mail Address: Ma/Li/ -"/e_1 , wrs-, QA Applications On Line \3 -2006 - Permit Application doc Revised: 9 -3006 hh City State Zip Day Telephone: 2,==. 6 • do 22 • 17'SD Fax Number: 2v6 • 62-2- • 0 5/22- Page 1 of BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ SOS Oo v Existing Building Valuation: $ Scope of Work (please provide detailed information): /t/A--(6— / a�vi��j �u �� MSS , Will there be new rack storage? ❑ Ycs No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: ,CV Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ..... Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No /f "yes'. attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantifies and Material Safety Dam Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q- Applications \Forms - Applications On Line A3- 2006 - Permit Application.doc Revised. 9 -2006 nn t'age 2 o(' 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per 113C 1s` Floor / /11( 7 /7-4' 1v7 rd Floor 27/68& 7/ / .17-,a M 3ra Floor ' D ■ _ Iv , ,'-7 Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: ,CV Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ..... Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No /f "yes'. attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantifies and Material Safety Dam Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q- Applications \Forms - Applications On Line A3- 2006 - Permit Application.doc Revised. 9 -2006 nn t'age 2 o(' 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Pennit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall he requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGF.AIT: Signature: Print Name: G�1�F )'t/br J6147- 4Sow// Date: ..5— Day Telephone: 2-06 ' 62y• 27? Mailing Address: yDdd ,d1;2/e /,6(v6r- `.d' S`..>!' - 5m–/7Z 4/A- City State 9,t/v6 Zip Date Application Accepted: Date Application Expires: Staff Initials: Q:A Applications \Forms-Applications On LineA3 -2006 - Permit Application doc Revised. 9 -2006 bh Page 6 of 6 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT 9202470010 2800 SOUTHCENTER MALL TUKW WESTFIELD MALL - GAS METER ALCOVE Permit Number: Status: Applied Date: Issue Date: D10 -117 ISSUED 05/05/2010 06/25/2010 Receipt No.: R10 -01432 Initials: User ID: JEM 1165 Payment Amount: $63.00 Payment Date: 07/28/2010 12:19 PM Balance: $0.00 Payee: BNBUILDERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. 52260 63.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 Total: $63.00 63.00 PAYMENT RECEIVED doc: Receipt-06 Printed: 07 -28 -2010 City of Tukwila sy Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-117 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/05/2010 Applicant: WESTFIELD MALL - GAS METER ALCOVE Issue Date: Receipt No.: R10 -01158 Payment Amount: $961.65 Initials: JEM Payment Date: 06/25/2010 09:50 AM User ID: 1165 Balance: $0.00 Payee: BNBUILDERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 51659 961.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 957.15 640.237.114 4.50 Total: $961.65 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -25 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 9202470010 Permit Number: D10 -117 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/05/2010 Applicant: WESTFIELD MALL Issue Date: Receipt No.: R10 -00773 Payment Amount: $622.15 Initials: JEM Payment Date: 05/05/2010 11:07 AM User ID: 1165 Balance: $961.65 Payee: S.M. STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15332 622.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 622.15 Total: $622.15 PAY MENT RECEIVED doc: Receiot -06 Printed: 05 -05 -2010 AtSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION.' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36470 Permit Inspection Request Line (206) 431 -2451• 1.6/6 '` // 7 Project: .57,P2,4/3 MA 11 Type of Inspection: ' m/4G Address: Date Called: X-&-r`,095#/.4 Special Instructions: ;4'f-4I4( ,:;-44 Date Wanted: ' /'r Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: X-&-r`,095#/.4 71/....1" (26;21'W/4 Al.- il•-•/4/04,/ / • N r--• l �• , SPECTION.FEE•REQUIR D. Prior t• next inspection: feemust be Id at 6300 Soutl center Blvd Suite 10 i . Call to.schedule reinspection. INSPECTION NO. . CITY OF TUKWILA BUILDING DI 6300 Southcenter Blvd., #100, Tukwila. WA 98188 INSPECTION RECORD Retain a copy with permit Did -1111 Permit Inspection Request Line (206) 431 -2451 orPER ' 17,140. (206) 431 -3670 Projeyc i 62 s , Type o Inspection: A Address: Date Called: { Specia nstructions: °t Ai titRequester. Date Wanted: 1 ' —` Phone OGY- 3S l ! 416 J. Approved per applicable codes. - orrections. required prior to approval. COMMENTS: `- 3 Sa.Vef brii ,1/iWsin aY dead, h f"1\41 5 a 1 cW A/dor' -ft, e. { . e...-1,--3 f i "—I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter-Blvd.. Suite 100. Call to schedule reinspection: ""'"ire-P100.." - .. ,,..•vr•-•--• ,e Amt ......,t.., • INSPECTION NO. INSPECTION RECORD Retain a copy with permit D(0 -111 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO., (206)431 -3670 Project We' e JUM ( Type of Insp ctiorL . -}-..� �� ( A Address: 2' d v s e A't)4-( I Date Called: Special Instructions: q t G /Meter Ate -,,,/� ,--, Date Wanted: / G J a.m_ Co -2-Er .('3 p.m. Requester: Phone No: ��— 5 - -33S3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: =k.spotA L h` i r nspe liAAAAs Date: —2' —/0 $6.00 REINSPECTION "EE REQUIRED. Prior to inspection, fee must be p. id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Rec-Ipt No.: 'Date: L. • Yi�+rdc4+�.i� "v .se``.�K4 rF : .:{li�dswu:i�frc8 ..ciihLF4i _ .+rxan =vkf: a INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /0 S_ -/4.. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, TukwiIa, Wa. 98188 _ - 206- 575 -4407 Project: t, ,..ess 'd1oG rI cia I Type of Inspection: .Sdr,'R Jd 1v 4.. 1/4";"J - Address: 21020 .5c 141404 Suite #: Contact Person: Special Instructions: Phone No.: /p (i� �" 'lei - 7 G4i I Approved per applicable codes. Corrections required prior to approval. COMMENTS: .5 ;r h er... 4.; j.t�:�,� J z.,: it,) 1r o,sra 1 OLy lea€21 ifr• 5144 Aitrre Needs Shift PAIS 3 Sprinklers: Fire Alarm: Hrs.: Hood & Duct: Monitor: „,-. Pre -Fire: . Permits: Occupancy Type: Inspector: PAIS 3 I Date: /o I2.fl0 Hrs.: / • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule's. reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Krazan & Associates, Inc. 922 Valley Avenue NW, Suite 101, Puyallup, WA 98371 (253) 939 -2500 Project No. 066 -10136 Weather Sunny Project WFSC- Gas Alcove Location Southcenter Mall Client Cyl. Code 1729 Pour Date 7/14/2010 Jurisdiction City of Tukwila RECEIVED 'AUG 252010t COMMUNITY MCI4T UCVLLv Report No. 7989 Permit No. D10 -117 Engineer Architect Contractor BN Builders Field Data Supplier Stoneway Time Truck# Ticket # 6:30 456 228636 MORTAR/GROUT REPORT Plant No. 11 Site Mix Flow or Slump % Air (in.) Grout Box Used x Number of units used to form specimens Grout Temp. (F) 68 Air Temp. (F) 62 Initial Max/Min Temp. (F) Placement Area Location 8" CMU WALL FROM 0' TO 8' SURROUNDING EXTERIOR GAS METERS ON EAST SIDE OF MALL JUST NORTH OF JC PENNY'S. Remarks PLEASE REFER TO FIELD REPORT NO. 130003 Inspector R. BOSMA Reported Batch Data Design Weights Mix No. 7054 Cem. lbs. 1974 F. Ash lbs. C. agg. lbs. 1 2683 2720 C. agg. lbs. 2 C. agg. lbs. 3 Sand lbs. 6208 6240 Water lbs. 792 790 Air Ent. (oz) Other (oz) Other (oz) Other(oz) Other (oz) Water Added on Job (gals.) 8 Actual Weights 7034 1960 Field Test Methods X ASTM C143 X ASTM C1064 ASTM C31 ASTM C138 ASTM C173 Other Laboratory Data Cyl. Code 1729 -1 1729 -2 1729 -3 1729 -4 Test Date 7/21/2010 8/11/2010 8/11/2010 8/11/2010 Remarks Results Reviewed B Age 7 28 28 28 Mid Pt. Width (in) 3.29 3.36 3.36 3.26 3.34 3.36 3.33 3.33 Design Strength 2,000 @ 28 days Cross Out of Section Max. Comp. Height Plumb Area Load Strength Tested Break (in) 6.250 6.250 6.250 6.250 Date Specimens Rec'd. 7/16/2010 ( %) (sq.in) (lbs) (psi) Set # By Type 11.05 40150 3,630 1 MT N/A 10.95 57775 5,280 1 MT N/A 11.22 59605 5,310 1 MT N/A 11.09 58345 5,260 1 MT N/A '5 /( 4: Sh ar Date Reviewed Codes for Break Types: / 1: Cone 2: Cone & Split 3: Cone & Shear Measurement Uncertai 'es: ASTM C109= +1- 10.7, ASTM C1019= +1- 14.4% Roan 04103 Revision 0 Effaces° Date 12/02/02 The intormafbn provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any fomiat without the written permission of the client and Krazan 8 Associates. /v Laboratory Test Methods ASTM C39 ASTM C109 X ASTM C617 X ASTM C1019 ASTM C1231 Test Results X Conforming Non - Conforming 5: Columnar (Split) FCEIVEDFIELD REPORT NO: 132586 & Associates, Inc:` GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: 7-2 -2o tc PROJECT #: ULCQ "IGIS1U PROJECT: /Ai 1 S Cf LOCATION: e af /QLCc'rg KRAZAN PROJECT MANAGER: eg� AUG 18 2010' COMMUNITY DEVELOPMENT CONTRACTOR: Bill QCL /e.46ns JURISDICTION: .7Z,Itzydm km-, PERMIT #: Vies - /17 INSPECTOR: clinelf" 4/4 -Al,d WEATHER: &yZC4fv' TEMP: 2v w ° ' ' ie I 7-g ,9s a ./ ' r „ - 410/V7 f+'iL/ CJ�G r' 7iV OMCJNe 6'72Zt t' /,0 CON ere- -74.6 77$S7Mfr' aJ /•�f/ , //}C/lNmttSi7— O $�GPP:41-7 /0,v4 m 'r / I h rZ t4Pfixev' 2 00mAed. f cSilCC.iicAr iatU 4L/- pie/were-6 77g srge CN 6�44w Ai- £14S gNCGas(,ee (e LCOvaJ DA/ r/f Ard9d77 O�.a/ k7 ,3eirLQ/ne6 �Z' f�0 �R i -'C -4 s Z, o � P � At-6/9/2 Oa/me 60 o4-r- /2'_"tcc S1441 004/46-Is ((.egk /o uJ/ 1-1- wl4g7 ;,4 ) L5/ /2& 3A, 47 210 (9G EAo )c /E!, /In; A16/J7 /av6 %I/Ad EOee Alv 0 " V /2ts ?A-e /17 /r oc e /Mb al-,erl1 of .v&" eL ∎24A eta »eki&et , /f,A £Pc /crtr S2 19—ivo P,4410 /2 614eoe /C2 / /vcf T/9/rZ,Z) O (JON catre : /11 t r JAL' d G /tirvcl Jt/ Piet /rd S-0 y.1 /1 ' ' /L O 44 7,91,94:e eu //41.e Co .vca rDrWoirt,6r,o tt/ a isc11-9/lst Mtn' fi '1 iliteRAi/ /cw //y retitabhztRria, !Y/D L J e-L (SJ S/x8 ecte7 ,0,e ..C.S% Lie $iRt.t a 7W - 7 CYL,"#404VS 42 LI4186 Dirro'y Carer AI f� teee- J7/9,vct -'7 - s'7'•.,. 6 ? a -TO CW,1 iz 0-Poterit. 34 3 ).#' veon D/7-AZ Equipment/Asset Number(s): To the best of my knowledge, the abov / WAS NOT performed in accordance with the ar.roved plans, specifications, and regulatory requirement: Superintendent/Representative: Tech c This report Indicates our inspector's observation and testing results based on the site condition and contractor's activi T is information is subject to review prior o final submittal. By signing this report, c inspector does not accept responsibility for validity of the results. Some information on this report may have been provided by others on site. The information provided on this report is prepared for the exclusive use the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Assoc. Offices Serving the Western United States Bothell (425) 485 -5519 Gresham (503) 665 -3574 Poulsbo (360) 598 -2126 Puyallup (253) 939 -2500 DAILY FIELD REPORT 2009.doc EFFECTIVE: 4/22/200! Krazan & Associates, Inc. 922 Valley Avenue NW, Suite 101, Puyallup, WA, 98371, (253) 939 -2500 Project No. 066 -10136 Weather Overcast Project WFSC Gas Alcove Location SouthCenter Mall Client Westfield Corporation -South Center Cyl. Code 1683 Pour Date Jurisdiction Tukwilla, Wa. Engineer Architect 7/2/2010 Report No. 36346 Permit No. 010 -117 RECEIVED 'AUG 182010 Contractor BN Builders cOMMUNIrr Field Data Concrete X Supplier Miles Other CYLINDER REPORT Plant No. 201 Time Truck# Ticket # % Air 10:00 18 239345 Slump (in.) 4.8 5 Mix Temp. (F) 67 Site Mix Air Temp. (F) 57 Unit Wt. (pcf) Placement Area Location GAS ENCLOSURE @ EAST SIDE OF MALL (NORTH OF JC PENNY). 5CYDS TOTAL. Remarks MIX DEPOSITED BY DISCHARGE CHUTE & H/F MECHANICALLY CONSOLIDATED PER PLANS. REFER TO FIELD REPORT #132586. Inspector J.BLAND Reported Batch Data Mix No. Cem. lbs. F. Ash lbs. C. agg. lbs. 1 C. agg. lbs. 2 C. agg. lbs. 3 Sand lbs. Water lbs. Air Ent. (oz) Other (oz) Other (oz) Other (oz) Other (oz) Water Added on Job (gals.) Design Weights 0160a 564 Actual Weights 0160a 2810 1860 9280 1260 275 5.6 6320 1089 28 18 Field Test Methods x ASTM C143 x ASTM C1064 x ASTM C31 OTHER ASTM C138 ASTM C173 ASTM C172 x ASTM C231 Laboratory Data Cyl. Test Code Date 1683 -1 7/9/2010 1683 -2 7/30/2010 1683 -3 7/30/2010 1683 -4 7/30/2010 1683 -5 1683 -6 1683 -7 1683 -7 Remarks Results Reviewed By Field Cure Codes for Break Types: Design Strength 3,000 @ 28 days Max. Age Dim. Area C.F. Load 7 4.01 12.63 36045 28 28 28 H Comp. Str. (psi) 2,850 Date Specimens Rec'd. 7/3/2010 Tested Break Set# By Type 1 1 1 1 1 Date Reviewed 7qj DH 2 Laboratory Test Methods X ASTM C39 ASTM C109 ASTM C617 X ASTM C1231 ASTM C780 Other Test Results Conforming Non - Conforming 1: Cone 2: Cone & Split 3: Cone & Shear 4. Shear 5: Columnar (Split) Measurement Unce/tainties: ASTM C -39 +/- 8% Forth 03101 Revision 3 Effective Date 5/17/00 The information provided on this report b prepared for the exclusive we of the client. This report may not be reproduced in any format without the mitten permission of the client and Krazan & Associates. I.r2L.Z21ITl & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: 7'/4/" /t7 PROJECT #: 064. ea/34. PROJECT: Gt9A-se- — s w+e LOCATION: KRAZAN PROJECT MANAGER: ,&.6 J�3. FIELD REPORT NO: 130003 O O O 3 peCE1�1�1D AUG 18 2010' C O N T RAMMEW., ' JURISDICTION: T�7� PERMIT #: .0/49— //7 INSPECTOR: ,c• /30,4,1...« WEATHER: .514-#1 "...I/ TEMP: 6.02° C-.044 -a d.►e^ t/ /.4t + T �^ PI c 1s.-t/ g /c,c,e- owls/ -»- .0"x244 445-s P ®. C, 444>c .; 7etil 1,4W-5 / ced "1/4.4 ex.w J G 12 6 d ,4 ' , /OF - A-L°.„:„, a s o•/ at./e S-u.,-d l LA el wwt rie1s t9,.� Qp.�� s- >/c w �. J�s,t ci/ J'G,Qe4w•ys O. Cr J fi��n•,��.. -->!d/ ,-� o'— g_ c S�� � ei -/ svp- .7a /1 e)P.,4,4-ow.ess'1e' .s `1''-4 74e 'e1 - Equipment/Asset Number(s): To the best of my knowledge, the abovt iXS L.'WAS NOT performed in accordance with the approved plans, specifications, and regulatory requirements Superintendent/Representative: Technician: �Z t27S3 This report indicates our inspector's observation and testing results based on the site condition and contractor's activities. This information is su.fect to re.r to final submittal. By signing this report, 01 inspector does not accept responsibility for validity of the results. Some information on this report may have been provided by others on site. The information provided on this report is prepared for the exclusive use the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Assoc. Offices Serving the Western United States Bothell (425) 485 -5519 Gresham (503) 665 -3574 Poulsbo (360) 598 -2126 Puyallup (253) 939 -2500 DAILY FIELD REPORT 2009.doc EFFECTIVE: 4/22/2001 Krazan & Associates, Inc. 922 Valley Avenue NW, Suite 101, Puyallup, WA 98371 (253) 939 -2500 Protect No. 066 -10136 Weather Sunny Protect WFSC- Gas Alcove Location Southcenter Mall Client Cyl. Code 1729 Pour Date Jurisdiction City of Tukwila Engineer Architect 7/14/2010 9 AUG 18 2010 Report No. 7989 17 contractor BN Builders COMMUNITY DEVELOPMENT Field Data Supplier Stoneway Time Truck# Ticket # 6:30 456 228636 MORTAR/GROUT REPORT Plant No. 11 Flow or Grout Slump Temp. % Air (in.) (F) 10 68 Grout Box Used x Number of units used to form specimens Site Mix Air Temp. (F) 62 Initial Max/Min Temp. (F) Placement Area Location 8" CMU WALL FROM 0' TO 8' SURROUNDING EXTERIOR GAS METERS ON EAST SIDE OF MALL JUST NORTH OF JC PENNY'S. Remarks PLEASE REFER TO FIELD REPORT NO. 130003 Inspector R. BOSMA Reported Batch Data Design Weights Mix No. 7054 Actual Weights 7034 Cem. lbs. 1974 1960 F. Ash lbs. C. agg. lbs. 1 2683 2720 C. agg. lbs. 2 C. agg. lbs. 3 Sand lbs. 6208 6240 Water lbs. 792 790 Air Ent. (oz) Other (oz) Other (oz) Other (oz) Other (oz) Water Added on Job (gals.) 8 Field Test Methods X ASTM C143 X ASTM C1064 ASTM C31 ASTM C138 ASTM C173 Other Laboratory Data Cyl. Test Code Date Age 1729 -1 7/21/2010 7 1729 -2 8/11/2010 28 1729 -3 8/11/2010 28 1729 -4 8/11/2010 28 Remarks Results Reviewed By Mid Pt. Width (In) 3.29 3.36 Design Strength 2,000 @ 28 days Cross Out of Section Max. Height Plumb Area Load (in) ( %) (sq.ln) (lbs) 6.250 - 11.05 40150 Comp. Strength (psi) 3,630 Date Specimens Rec'd. 7/16/2010 Set # 1 1 1 1 Tested By MT C / 19 4: hear Date Reviewed Codes for Break Type: 1: Cone 2: Cone & Split 3: Cone & Shear Measurement Uncertainties: ASTM C109= +1- 10.7, ASTM C1019= +1- 14.4% Form 04103 Revision 0 EffeaM Date 12/02/02 The information provided on this report b prepared for the exclusive use of the dived. This report may not be reproduced in any format without the written permbdebn of the client and Mean & Associates. Break Type N/A Laboratory Test Methods ASTM C39 ASTM C109 X ASTM C617 X ASTM C1019 ASTM C1231 Test Results Conforming Non - Conforming 5: Columnar (Split) Krazan & Associates, Inc. 922 Valley Avenue NW, Suite 101, Puyallup, WA, 98371, (253) 939 -2500 • 'Project No. 066 -10136 Cyl. Code 1683 Pour Date 7/2/2010 Report No. 36346 Weather Overcast Jurisdiction Tukwilla, Wa. Permit No. 010 -117 Project WFSC Gas Alcove Engineer ,_ ,R •��C E3V E Location SouthCenter Mall Architect Client Westfield Corporation -South Center Contractor BN Builders AUG 1 8 20101 Field Data Concrete X Other Supplier Miles CYLINDER REPORT Plant No. 201 Site Mix Mix Alr Unit Slump Temp. Temp. Wt. Time Truck# Ticket # % Air (in.) (F) (F) (pcf) 10:00 18 239345 4.8 5 67 57 - Placement Area Location GAS ENCLOSURE @ EAST SIDE OF MALL (NORTH OF JC PENNY). 5CYDS TOTAL. Remarks MIX DEPOSITED BY DISCHARGE CHUTE & H/F MECHANICALLY CONSOLIDATED PER PLANS. REFER TO FIELD REPORT #132586. Inspector J.BLAND .. UMMUNI 1 Y Reported BatchLOPMENT Design Actual Weights Weights Mix No. 0160a 0160a Cem.lbs. 564 2810 F. Ash lbs. C. agg. Ibs. 1 1860 9280 C. agg. lbs. 2 C. agg. lbs. 3 - Sand lbs. 1260 6320 Water lbs. 275 1089 Air Ent. (oz) 5.6 28 Other (oz) Other (oz) Other (oz) Other (oz) Water Added on Job (gals.) 18 Field Test Methods x ASTM C143 ASTM C138 x ASTM C1064 ASTM C173 x ASTM C31 ASTM C172 OTHER x ASTM C231 Laboratory Data Design Strength 3,000 @ 28 days Date Specimens Rec'd. 7/3/2010 Cyl. Test Field Max. Comp. Tested Break Code Date Cure Age Dim. Area C.F. Load Str. (psi) Set # By Type 1683 -1 7/9/2010 7 4.01 12.63 36045 2,850 1 DH 2 1683 -2 7/30/2010 28 4.00 12.57 14850 3,810 1 MT 4 1683 -3 7/30/2010 28 4.00 12.57 49990 3,980 1 MT 2 1683 -4 7/30/2010 28 4.00 12.57 48695 3,870 1 MT 4 1683 -5 H 1 1683 -6 1683 -7 1683 -7 Remarks Results Reviewed By Codes for Break Types: Date Reviewed 7 Iv 1: Cone 2: Cone & Split 3: Cone & Shear 4: he 5: Columnar (Split) Laboratory Test Methods X ASTM C39 ASTM C109 ASTM C617 X ASTM C1231 ASTM C780 Other Test Results X Conforming Non - Conforming Measurement Uncer(ainties: ASTM C -39 +/- 8% Form 03101 Revision 3 Effective Data 6112104 The information provided on this report Is prepared for the exclusive use of the client. This report may not be reproduced In any format without the written permisalon of the client and W azan d Associates. r) S ETERSON _JTREHLE 1 JARTINSON, INC. CONSULTING ENGINEERS STRUCTURAL CALCULATIONS & SKETCHES r}Ir rnt►IEPP4 AOQtVInl SUb!er,i tQ f?!Tt`t'' . nfilieSIrMA Gas Meter Alcove - Westfield Mall Tukwila, WA By PSM Engineers PSM Job # 10026 CITMSIA MAY 0 5' 2010 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPMWED JUN 17 2010 City of Tukwila BUILDING Divisinwi April 22, 2010 IEXPIRES 01/09/2011 2200 SIXTH AVENUE, SUITE 601 SEATTLE WASHINGTON 98121 PHONE 206 - 622 -4580 FAX 206 - 622 -0422 totM E AST. TENANT DROP BOX TO REMAIN D I ST. EXTERIOR WALL ASSEMBLY TO ROIASN ■ CONCRETE SLAB ON GRADE £i1. 5 Ii 0 01 -' RE STRUCTURAL \ 01 .l \ EXIST. SIDELLNL7 at MOLL WON BRICK VENEER - SEE WALL TYPE LANDSCAPE AREA - PLANTS TO BE DETERIIED BT OWNER 5' -0' CLEAR TENANT GAS METERS AND MUWFOLD I:E RGET SAND ETERGT EXIST. BIKE RACK TO SE RELOCATED TO EOM SIDE OF WES1RELD ENTRY EXISTING GAS RISER TO RB'1AIN OUTLINE OF EXIST LANDSCAPSNG TO BE REVISED 0/TN ALCOVE H 1'-®' OUTLNE CF SOFFIT ABOVE FLOOR PLAN 1/2° = 1'-0' fug (2) #4 CONT HORIZ AT TOP Embed 3 t14u Cac111- 115 '47 RE Soo S• #4 AT 12 "0C 2 -6 (2) #4 CONT HORIZ AT 32 "0C 5VERT AT CL AT 24 "0C, BEND INTO FTG 2) #4 CONT AT BASE FIN GRADE numor •ime=gus law 4" ()a #4 AT 18 "0C EACH WAY z 0 (3) #6 CONT Q SECTION 1/2" = 1' -0" PSM CONSULTING ENGINEERS 2200 SIXTH AVENUE, SUITE 601, SEATTLE, WASHINGTON 98121 OFFICE 206.622.4580 www.psm - engineers.com JOB: Welt-6 da -'%an Pc( GWt DATE: 412 24 t o BY: /MSS/ SUBJECT: LAXAx12.1AxAsYeid "1 C2-) # f2 - sGre,a‘ 8 deck f r , t K : S - (T1 p e_e -s'. c.) H SS 1.2-7* IcS /1 4 _. roof ctt k L4 x.4-x ►254 x Eh Y ,1 . W/ 0:3 .tt 12 St ree..*An 3 deck:- ", . {3� # t _ -.5c.re_wa • 'to - HSS . CTYp. es; -si j roof !eck Hiss 12_,‘A x3/ 6 H SS. (z.?(4 .\v . C) EooF. Deck. GDin i dx'n, PSM CONSULTING ENGINEERS 2200 SIXTH AVENUE, SUITE 601, SEATTLE, WASHINGTON 98121 OFFICE 206.622.4580 www.psm - engineers.com JOB: UIE.S.-I-Wel 6-an P\tc.uve. DATE: 4121-4113 BY: rv`SV SUBJECT: NSS LP, 4414. Pass Wu) CC-1. so - -fvaw,\Z L > 4 x4xtz� a �t.glde. (4) *IL sift e.t 40 tisu (2_9 *t2 screws lo 5.11.1.4 ' 1300s.zdo - 54 on . eA s:de 1 iS.S p ^U 32 ) tttc10 +0 wall S-Svds wi .._. . 19 ) W4l somas Errr-k- ere .H.SS 12x4_ . b .��� J Pi. Stu4 Groot e Cantilever CMU wall Sds = 1= Fp = ap = Rp = Fpb = Fpt = Wall wt, Wp = Wall height, H = fm' = Moment Mp = Moment Mpb = Vp = Vpb = d= As = a= Phi(Mn) = Reinforcement Spacing reqd 0.854 1 0.3416 0.4xSdsxl 1 per Table 13.5 -1 2.5 0.13664 at base 0.40992 at top 115 psf to/ 'lamer 8.5 ft above footing 1500 psi 1419.135 Ibft/ft 1324.526 I bft/ft 333.914 lb/ft 267.1312 lb/ft due to Fp due to Fpt and Fpb 3.83 in 0.087184 in2/ft 0.363266 in 1431.353 Ibft ok #5 As = 3.56 ft 0.31 Footing Mb = Footing b= t= Mb' = Wall wt = Ftg wt = P= RM = e= q soil = 993.3942 ASD moment at ftg top 3.5 ft 1.5 ft 1344.004 Ibft/ft 977.5 lb/ft 787.5 lb/ft 1059 lb /ft 1853.25 1.269125 ft 1468.158 psf moment at ftg base 27.4988 psf FS = 1.378902 ok PSM CONSULTING ENGINEERS 2200 SIXTH AVENUE, SUITE 601, SEATTLE, WASHINGTON 98121 OFFICE 206.622.4580 www.psm - engineers.com JOB: We 1t se d GeAn AtGWE-' DATE: 4/22-( BY: MSV SUBJECT: Use - asst zx4Y 1j4.. ;7 E . erctnSC- ( S- 1)A41- P, -P . Izb.4 - -L“e- Paist wt..0 .sod1 . b. s■l:rv,+- pt +- ti-SS. 5..h4 c ,s.me.se.d 6 oo. St 37 _ 3'S e e c 6 r_. ... .t\AS x . S"prC-4" sp A.C- _2:-:(3 C. 12- S.iz M�4x a I" Sr_ •a�LGB 5 U .Se_ CZ) l._4 ?fix 12 ek ..... COVNG .S =. 0 • .12rt =.lY C�e,IZ.S.t/YGwS 9 ST Ve, = 1St" 74 vg-i. aiu4 zosi L4/ ,Cam).. Ns s �,,d _.:cl'r - ok 61_ „Mpetkhe,.... 1 rr��4 V 1Ir 244 4 x _ mix • _4%eaY ..�/ X (CU loo 1t- ea. C.keck ,0411 . sue. =4-bo . . 12 iM - S 7'c4 Y1 Sr 4 0.114 611 oOS137 -33 =a s = o-s-n `1- t< m-_ R = 173 C I T . ---ok 2 , per. tY Ott QNtalV S s 11irs Cmvvr,cc'ininn tMOS4-tAI ,ay s■eiuti✓ s1=-4L 1141 �.. 0.d -b ltrab; )e.ck eYU 'Ail est k4 ce L4,(4),‘ Z ,::trycyvv,A i°_.d - co ors by *12_ • • S.M. STEMPER 8 ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y June 30, 2010 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Mall Gas Meter Alcove Project No. D10 -117 — Owner Revision #1 Attention: Moira Bradshaw Per our discussion we are submitted the Civil and Landscape plans associated with the landscape islands as requested. We are including the new sheets as follows: Civil Cover Sheet, D -1.0, C -1.0, C -1.1, L -1, L -2, and L -3. In addition to the new sheets we have also revised the architectural site plans sheet A0.0 to reflect the revised shape of the islands. The shape of the islands were modified due to the parking requirement and to avoid deleting any parking stall. Therefore the islands actually became larger and help identify the drive line better than previously submitted. Please accept this written clarification, regarding the revisions. Each of the revisions are clouded and indicated on the drawings per City of Tukwila requirements. If you should have any further questions please feel free to call. Sincerely, Wayne E. Johnson, AIA S.M. Stemper Architects Cc: Pat Burns, Westfield Encl.: Revision Submittal Form 4000 DELRIDGE WAY SW . SUITE 200. SEATTLE, WA 98106 • 206/624 -2777. FAX 206/624 -2973 b • S.M. STEMPER ■ ARCHITECTS A Professional Limited Liability Company June 14, 2010 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Mall Gas Meter Alcove Project No. D10 -117 Attention: Moira Bradshaw Listed below is the written response to the `Correction Letter #2' dated June 8, 2010 which we received on June 11, 2010. In accordance to the memo we are submitting written clarifications below along with modifications to the drawings to the `Planning Division Comments'. Listed below is a brief description of your comments and our responses: 1. Item' #1 — Remove the 5 deciduous trees along with the curb edge extending north from the mall's eastern entrance. • Response — The 5 deciduous trees along the curb north of the mall's east entrance are shown to be removed on sheet A0.0. 2. Item #2 — Create 10 landscape islands along the internal circular drive aisle • Response — Sheet A0.0 shows the 10 landscape islands along with the new replacement trees. 3. Item #3 — Submit a planting plan that replaces the 5 trees with 10 deciduous trees and shrub, and groundcover berming up to minimize pedestrian intrusion. • Response — As discussed and agreed with you during the site walk with the landscape architect and owner the planting plan will be submitted by Glander and Associates to clarify the planting requirements that we all agreed to on Friday June 4, 2010 4. Item #4 — Show revised parking lot striping and dimensions. • Response — Sheet A0.0 shows the dimensions of the revised parking and landscape islands in accordance to the City of Tukwila zoning requirements. 5. Item #5 — Relocate bike rack • Response — The bike rack is removed and a new one is shown to be located just south of the east entrance on A0.0. 6. Item #6 — Show tree pit resurfacing • Response — Sheet A0.0 and A1.0 show the demolished tree grates to be infilled with concrete sidewalk to match existing concrete texture and finish. Please accept this written response to your memo, regarding the revisions. Each of the revisions are clouded and indicated on the drawings per City of Tukwila requirements. If you should have any further questions please feel free to call. Sincerely, Wayne E. Johnson, AIA S.M. Stemper Architects Cc: Pat Burns, Westfield Encl.: Revision Submittal Form 4000 DELRIDGE WAY SW . SUITE 200. SEATTLE, WA 98106. 206/624 -2777. FAX 206/624-2973 June 8, 2010 City of Tu { Ya_ lla Department of Community Development • Jim Haggerton, Mayor Wayne Johnson S M Stemper Architect 4000 Delridge Way SW #200 Seattle, WA 98106 RE: Correction Letter #2 Development Permit Application Number D10 -117 Westfield Mall Gas Meter Alcove — 2800 Southcenter Mall Jack Pace, Director Dear Mr. Johnson, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire, and Public Works Departments have no comments. Planning Department: Moira Bradshaw at 206 - 431 -3651 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ifer ar all it Te cian encl File No. D10 -117 ok4de W:\Pennit Center \Correction Letters \2010\D10-117 Correction Letter #2.DOC 6300 Southcenter Boulevard, Suite #100 a Tukwila, Washington 98188 • Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 kr • PLANNING DIVISION COMMENTS From : Moira Carr Bradshaw Date: 8 June 2010 Subject: D10 -117 — Westfield Mall Gas Meter Alcove Please revise the plans per our 6/4/2010 field discussion: 1. Remove the 5 deciduous trees along the curb edge extending north from the mall's eastern entrance. 2. Create 10 landscape islands along the internal circular drive aisle. 3. Submit a planting plan that replaces the 5 trees with 10 deciduous trees and shrubs and groundcover berming up to minimize pedestrian intrusions. 4. Show revised parking lot striping and dimensions. 5. Relocate bike rack 6. Show tree pit resurfacing H: \WEA phase 2 \D10 -117 Gas Alcove#2.doc S.M. STEMPER • ARCHITECTS A P r o f e s s i o n a l L i m i t e d L i a b i l i t y C o m p a n y May 25, 2010 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Mall Gas Meter Alcove Project No. D10 -117 Attention: Moira Bradshaw Listed below is the written response to the `Correction Letter' dated May 19, 2010 which we received on May 24, 2010. In accordance to the memo we are submitting written clarification regarding the Planning Division Comments and per our discussions on May 17, 2010. Listed below is a brief description of your comments and responses: 1. Item #1 — Relocate tree pits and plant with same /similar tree species to ensure minimum of 5' -0" walking /sidewalk. • Response — Tree pits are indicated to be relocated and trees shall be installed to match existing as coordinated with the Landscape Architect. 2. Item #2 — Create a raised landscape area in front of wall and plant with evergreen vine and ground cover to soften wall. • Response — The plans, sections, and elevations have been revised to show the raised landscape area as well as the cable trellis. The landscaping and vegetation shall be per our conversations and as recommended by the Landscape Architect. 3. Item #3 — Install a system for `climbing' vine. • Response — The sections and elevations show the cable trellis system that matches the same trellis that is used on the Fidelity Bank elevation, which Westfield anticipates using the same trellis at other future conditions. 4. Item #4 — Face Raised landscape area with material compatible with brick facade and wall - preferably same as wall or building material. • Response — The raised area will use a precast concrete curb to be consistent with the curbs that are being installed along the Seafood City expansion just to the north of the alcove along the same sidewalk. Please accept this written response to your memo, regarding the revisions. Each of the revisions are clouded and indicated on the drawings per City of Tukwila requirements. If you should have any further questions please feel free to call. Sincerely, 14/el‘i Wayne E. Johnson, AIA S.M. Stemper Architects Cc: Pat Burns, Westfield Encl.: Revision Submittal Form CORRECTION LTR# I RECEIVED MAY 25 2010 PERMIT CENTER 4000 DELRIDGE WAY SW . SUITE 200 . SEATTLE, WA 98106 . 206/624 -2777 . FAX 206/624 -2973 May 19, 2010 Jim Haggerton, Mayor epartment of Community Development Jack Pace, Director Wayne Johnson S M Stemper Architect 4000 Delridge Way SW #200 Seattle, WA 98106 RE: Correction Letter #1 Development Permit Application Number D10 -117 Westfield Mall Gas Meter Alcove — 2800 Southcenter Mall Dear Mr. Johnson, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire, and Public Works Departments have no comments. Planning Department: Moira Bradshaw at 206 - 431 -3651 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, <-1)-AV Bill Rambo Permit Technician encl File No. D10 -117 W:\Permit Center\Correction 1•etters\2010\D10 -117 Correction Letter #I.DOC 6300 Southcenter Boulevard, Suite #100 a Tukwila, Washington 98188 • Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 PLANNING DIVISION COMMENTS Date: 17 May 2010 Subject: D10 -117 — Westfield Mall Gas Meter Alcove Planner: Moira Carr Bradshaw Please revise the plans per our 5/17/2010 discussion: 1. Relocate tree pits and plant with same /similar tree species to ensure a minimum of 5 foot walking/sidewalk. 2. Create a raised landscape area in front of wall and plant with evergreen vine and ground cover to soften wall. 3. Install a system for "climbing" vine. 4. Face raised landscape area with material compatible with brick facade and wall — preferably same as wall or building material. H: \WEA phase 2\D10 -117 Gas Alcove.doc • ERMIT CoAm COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -117 DATE: 06/30/10 PROJECT NAME: WESTFIELD GAS METER ALCOVE SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued ,DDEPARTMAE'�NTS: BulidingDisi PubIic Works NJ 4-1° Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete tgl Comments: Incomplete U DUE DATE: 07/01/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/29/10 Approved Approved with Conditions n Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 6 PERMIT cooRDcoMO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -117 DATE: 06/14/10 PROJECT NAME: WESTFIELD MALL - GAS METER ALCOVE SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 2 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete WI Comments: Incomplete ri DUE DATE: 06/15/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/13/10 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -117 DATE: 05 -25 -10 PROJECT NAME: SOUTHCENTER MALL - GAS METER ALCOVE SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural lanni g Ivislon Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05 -27 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW [1 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-24 -10 Not Approved (attach comments) t DATE: Permit Center Use Only j CORRECTION LETTER MAILED: ' { 1111,11 ' Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: Documents /routing slip doc 2 -28 -02 ikER IT COORD COPS • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -117 DATE: 05/05/10 PROJECT NAME: WESTFIELD MALL - GAS METER ALCOVE SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS:f� :ui 'ng t\\ID is Works 11-04 %4 -UWC. S —(3 -(D m3 �,.e%' %el ire Prevention ❑ Planning Division Structural F7Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05/06/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route It REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required Li DATE: APPROVALS OR CORRECTIONS: Approved U Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 06/03/10 Not Approved (attach comments) DATE: Permit Center Use Only •5 � '\ CORRECTION LETTER MAILED: ( l j — 4 0 • Departments issued corrections: Bldg ❑ Fire ❑ Ping PW ❑ Staff Initials: vik Documents/routing slip.doc 2 -28 -02 PROJECT NAME: SITE ADDRESS: 14W C JAp(1L- PERMIT NO: (7 i D--111 ORIGINAL ISSUE DATE: ()(p. REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 dt1/•(7* by 1 i1'Oi 1) � Summary of Revision: f -ev1�t o 1, 'b69C, Ai' ∎ N (r — C,t .A L,� C,l+�io � A LT Df V6 ■1& D1UL Received by: V.o q ey C_,y SAN/) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: c .11., i 2-b 1D Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # gRevision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: .STFI t� '�1Z_ AL6_ V(� Project Address: Z $CDO Contact Person: �,(p�I.(� � *(�iJ Phone Number: 2 ' (o • 6 • Z7 7 ) Summary of Revision: • 5 u s?,/c% tTT11J�� Ars t6u 1�. LtdI L LP i -! DSc- ' _ L • Is p- (- fl S k iAi SPcn&e 01..1ELC -,uiz flF LAY`-115c L.1 R. A LAN MCA • SheetNumber(s): A D.(D, La tot_ St*± ' ' i.O L" 1• ° L1 •1 / L1 L-21 L- 1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 0 H:\Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4000 ❑ Response to Incomplete Letter # ® Response to CorrectiofrLtter # 2 ❑ Revision # after Pe it is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan ChecWPermit Number: D10-117 Project Name: Westfield Mall — Gas Meter Alcove Project Address: 2800 Southcenter Mall Contact Person: LL1Lwl.-11:S— ja 0� Phone Number: OP rucwitA JUN 142010 PERMIT CENTER �G .62y. 2-77, Summary of Revision: \/LSE KA-A ,S • $ (1 kI P[ la'►et -(r_ pkg-KitJ Ac j _c A<A4b. Sheet Number(s): A/9.d , 4 / d, A2• v "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Mtck,,1,2 \applications \forms - applications on Iine\revision submittal Created: 8 -13 -2004 Revised: • • City of Tukwila Steven M Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: MAY- 2-5- 12010 Plan Check/Permit Number: D10-117 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Westfield Mall - Gas Meter Alcove Project Address: 2800 Southcenter Mall Contact Person: Mr.1lc .sA}t- OSWd Phone Number: 20 • 624 '237 7 Summary of Revision: Lo 1l�S 14494y (g. iS -t-t) s I-614 t-itna :._ 0 MIL Loczi At› 114-e- 12-Act f- VE2E 7LJ i a U(2 I Sheet Number(s): ,41. , 4/J / 42. 0 "Cloud" or highlight all areas of revision including date of revi� Received at the City of Tukwila Permit Center by: 1R---Entered in Permits Plus on S-)1\ ellECED CITY OF 1 iKW LA MAY 2 5 2010 Paw maul \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: • • Joanna Spencer - RE: WESTFIELD GAS METER ALCOVE D10 -117 From: "Bill Fortunato" To: "Joanna Spencer" Date: 07/06/2010 2:45 PM Subject: RE: WESTFIELD GAS METER ALCOVE D10 -117 CC: Page 1 of 1 Joanna - Good afternoon. In response to your question from last Friday, the DCVA for the irrigation system will not be moved or worked on as a result of this project. The irrigation being installed connect to the existing irrigation main located on site. I contacted the landscape architect, Jeff Glander, and he confirmed this information. Thank you. Bill Fortunato PAC LAND 1505 Westlake Ave N., Suite 305 Seattle, WA 98109 Office: (206) 522 -9510 x1125 Fax: (206) 522 -8344 TURNING VISIONS INTO RE4 LITY From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Friday, July 02, 2010 3:59 PM To: Bill Fortunato Cc: Joanna Spencer; pburns @westfield.com Subject: WESTFIELD GAS METER ALCOVE D10 -117 Bill, Would you please clarify if the irrigation Double Check Valve Assembly (DCVA) will be installed, moved or worked on as result of this project. Thanks, Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 - 431 -2440 fax: 206 - 431 -3665 jspencer@ci.tukwila.wa.us DID - 11-1 file: / /C: \Documents and Settings \joanna.TUKWILA \Local Settings \Temp\XPgrpwise \4C... 07/06/2010 1 1 4" OAK EXISTING PARKING STALL STRIPING TO REMAIN VARIES - SEE CIVIL 5" PLUM 14" OAK 10' -9 3/4" LIGHT BOLLARDS (3) OWNER FURNISHED CONTRACTOR INSTALLED i 16" PLUM- " OAK LANDSCAPE ISLAND WITH TREE AND VEGETATION RE: LANDSCAPE / Ii 10" OAK 6" CONCRETE CURB ISLAND RE: CIVIL • 1 /, ///://8 SLUM TYPICAL LANDSCAPE ISLA 1/4" = 1' -0" 12" OAK 8" PL 1M EXISTING PARKING TO REMAIN DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTING LIGHT BOLLARDS (3) OWNER RJRNISHED CONTRACTOR INSTALLED DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTIN G LIGHT BOLLARDS (2) OWNER RJRNISHED CONTRACTOR INSTALLED { 11" PLUM- EXISTING PARKING ST PLUM STRIPING TO REMA // 5" DE 10I -8 3/4" 12" OAK FIL. CipPY DEMO TREE AND GRATE (2) INFILL WITH CONCRETE TO MATCH EXISTING LIGHT BOLLARDS (2) OWNER FURNISHED CONTRACTOR INSTALLED GAS ALCOVE - SEE LARGER PLANS EXISTING PARKING TO REMAIN 12" PLUM_. VARIES - SEE CIVI Plan review approval is subject . errors and omissions. Approval of construction documen does not authorize the violation of any adopted code or , t inance. Receipt of approved Field Copy and conditions I : cknowledged: OAK < 16" PLUM- By gate: i o BIKE RACK TO BE REMOVED AND NEW RACK INSTALLED SOUTH OF WESTFIELD ENTRANCE DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTING BIKE RACK TO MATCH RACKS AT SOUTH SIDE OF MALL City Of liakwila BUILDING DIVISION 1 6" PLUM- GRASS 6" CONCRETE CURB ISLAND RE: CIVIL N\NN 14" PLUM,- TYPICAL LANDSCAPE ISLAND 1 /4" = 1' -0" REVISIONS No cha ges shall be made to the scope of v rk without prior approval of ukwila Building Division. NOTE: Re isions will require a new plan st limit+ 'l and may include additional p ;arl ref=,,' . Y203. ._..., REVIEWED FOR CODE COMPLIANCE APPROVED JUL 14 2010 City of Tukwila BUILDING DIUI.CIMi < -, GENERAL NOTES: GRASS \\N 16" PLUM- 1 LANDSCAPE AND CIVIL PLANS SHALL BE SUBMITTED SEPARATELY SHOWING THE DETAILS OF THE LANDSCAPE ISLAND, DRIVES, AND PLANTING DETAILS. 2. CONTRACTOR SHALL REMOVE EXISTING STRIPING AND REVISE THE STRIPING AS SHOWN TO ACCOMMODATE THE REQUIRED PARKING STALLS ADJACENT TO EACH LANDSCAPE ISLAND. 3. CONTRACTOR SHALL REMOVE TREES AND GRATES DESIGNATED TO BE REMOVED AND INSTALL MINIMUM 4" CONCRETE SLAB ON GRADE SIDEWALK INFILL WITH REQUIRED REINFORCING PER CIVIL PLANS. CONCRETE SHALL MATCH EXISTING CONCRETE SIDEWALK N FINISH, TEXTURE AND COLOR AS BEST AS POSSIBLE. 4. LANDSCAPE ISLANDS SHALL NOT IMPEDE ON REQUIRED DRIVE WIDTH, PARTICULARLY FIRE LANE NDICATED ALONG EAST SIDE OF BUILDING. 5. SEE CIVIL PLANS FOR PRECISE DIMENSIONS AND LOCATION OF ISLANDS. TYPICAL ISLANDS SHOUN ABOVE ARE ARE FOR CLARIFICATION ONLY. CIVIL PLANS HAVE THE DIMENSIONS FOR EACH LANDSCAPE ISLAND. )_ ANDSCAPE ISLAND GENERAL SQUARE FEET: LANDSCAPE ISLAND - A: 199 SF LANDSCAPE ISLAND - B: 214 SF LANDSCAPE ISLAND - C: 141 SF LANDSCAPE ISLAND - D: 105 SF LANDSCAPE ISLAND - E: 104 SF LANDSCAPE ISLAND - F: 109 SF LANDSCAPE ISLAND - G: 106 SF LANDSCAPE ISLAND - H: 165 SF LANDSCAPE ISLAND - J: 100 SF < 3"PLUM ARCHITECTURAL SITE PLAN 1" = 30' -0" f RECEIV iYOFTU LN JUN 5 0 2010 PERMIT CENTER REVISION NO 1 0 sesom- Wes/Ilek! South center 633 Southantr Parkway Tak w. WA.. 981e8 -2888 208 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS TIE PROPERTY OF RE ARCHITECT AND MAY NOT DE REPRODUCED WITHOUT THE ARCHITECT'S PEaBSSION AND UNLESS THE RERCOIUCRON CARRIES THE ARCHITECT'S NAYS ALL DESIGN AND OTHER INFORYAXN S14O1144 ON THE CRAVING ME FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98100 (206) 624 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: �OO wcO r Z 0) w U < w O J CD co N A6 -30-10 A6-11-10 PERMIT SET MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ SITE PLAN A0.0 SMSA #1022.02 28, 2010 3:30pm S: \Washington \TUKWILA \Westfield \0 NORTH MALL EXPANSION \LANDSCAPE ISLANDS \2DWGS \TULI0O1C.dwg PROJECT LOCATION CITY OF TUKWILA INTERSTATE -405 KWNLA PARKWAY STRANDER BLVD VICINITY MAP N.T.S. CONSULTANTS CIVIL: PACLAND 1505 WESTLAKE AVE. N., SUITE 305 SEATTLE, WA. 98109 (206) 522 -9510 CONTACT: BILL FORTUNATO, P.E. SURVEYOR: PACE 1601 SECOND AVE., SUITE 1000 SEATTLE, WA 981019 (206) 441 -1855 CONTACT: NEIL CABAGE, P.L.S. LANDSCAPE: JEFFREY B. GLANDER & ASSOCIATES 1821 4th AVE. E. OLYMPIA, WA 98506 (360) 357 -6972 CONTACT: JEFFREY GLANDER, R.L.A. EXISTING LEGEND UTILITIES STORMWATER: CITY OF TUKWILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 CONTACT: RYAN LARSON, P.E. (206) 433 -0179 WATER, SEWER: CITY OF TUKWILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 CONTACT: (206) 433 -0179 GAS: PUGET SOUND ENERGY 10885 NE 4TH STREET BELLEVUE, WA 98004 -5591 (425) 456 -2942 ELECTRIC: PUGET SOUND ENGERY /PETELCO 14103 8TH STREET EAST SUMNER, WA 98390 CONTACT: (253) 863 -0484 TELEPHONE: QWEST COMMUNICATIONS 1600 7TH AVE SEATTLE, WA 98191 (206) 398 -2500 estfie�aC SOUTHCENTER MALL EXPANSION TUKWILA, WASHINGTON REVS1ON NOLL LANDSCAPE REVISIONS N0- wi GOVERNING AGENCIES CITY OF TUKWILA CONSTRUCTION NOTES CITY OF TUKWILA 6200 SOUTHCENTER BLVD. TUKWILA, WA 98188 (206) 433 -1800 SITE DATA EXISTING ZONING = TUC EXISTING USE = RETAIL PROPOSED USE = RETAIL DATUM HORIZONTAL DATUM: DEED & RECORD OF SURVEY IN SECTION 23-23-04 BASIS OF BEARINGS: HELD NO0•14'09 "W ALONG EAST LINE OF SW 1 /4, SE 1 /4 23 -23 -4. VERTICAL DATUM: PER EXISTING SURVEY BY APEX ENGINEERING PLLC UNDER FILE NO. 28368 DATED 6/11/04. BELIEVED TO BE TO NGVD 1929 DATUM. WATER VALVE (APEX) IRRIGATION CONTROL BOX POST INDICATOR VALVE FIRE DEPARTMENT CONNECT HYDRANT WATER METER WATER MANHOLE ;i (L:!) MANHOLES (SS /SD) i (APEX) MANHOLES n CB POWER /UTILITY HAND HOLE 0 POWER /U11LITY POLE GUY ANCHOR POWER TRANSFORMER POWER /TELEPHONE VAULT TELEPHONE /TV RISER r_t GAS VALVE TRAFFIC LIGHTS STREET LIGHT LIGHT STANDARD SIGN (APEX) SIGN zaT.(`T.; . ROCKERY CONIFEROUS TREE DECIDUOUS TREE (TYPE UNKNOWN) MAP= MAPLE; OR= ORNIMENTAL 2 " -4" DECORATIVE TREE c ) SHRUBS FOUND CASED MONUMENT SS SPOT ELEVATION BOLLARD CONCRETE WALKWAY STORM /SEWER CLEANOUT CE:NTER LINES PROPERTY LINES RIGHT -OF -WAY LINES PLAT LINE WATER LINE SANITARY SEWER LINE STORM DRAIN LINE GAS LINE UNDERGROUND POWER LINES UNDERGROUND TELEPHONE LINES CHAIN LINK FENCE STRIPING BUILDING OVERHANG 1. ALL WORK PERFORMED SHALL BE PER APPROVED PLANS AND SPECIFICATIONS ONLY. THE PERMITTEE IS REQUIRED TO MAINTAIN A SET OF APPROVED PLANS, SPECIFICATIONS, AND ASSOCIATED PERMITS ON THE JOB SITE. WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL LAWS. PERMITTEE SHALL APPLY FOR A REVISION FOR ANY WORK NOT ACCORDING TO THE APPROVED PLANS. 2. PERMITTEE /CONTRACTOR SHALL ARRANGE A PRECONSTRUCTION CONFERENCE WITH THE CITY'S INSPECTOR(S) PRIOR TO BEGINNING ANY WORK. 3. WORK IN ROADWAYS A. ALL WORK IN ROADWAYS SHALL MEET TMC 11 AND THE FOLLOWING: B. PRIOR TO ANY ACTIVITY IN CITY RIGHT —OF —WAY, THE PERMITTEE SHALL PROVIDE THE CITY A TRAFFIC CONTROL PLAN FOR REVIEW AND APPROVAL. THE TRAFFIC CONTROL PLAN SHALL INCLUDE THE LOCATION, ADDRESS AND DESCRIPTION OF TRAFFIC FLOW DURING THE WORK AND SHALL MEET MUTCD REQUIREMENTS. C. ALL WORK REQUIRING LANE CLOSURES MUST BE BY PERMIT ONLY. FROM THE THIRD THURSDAY IN NOVEMBER TO THE FOLLOWING JANUARY 2ND, THE DIRECTOR DOES NOT ALLOW LANE CLOSURES IN THE TUKWILA URBAN CENTER. D. FIRE, PEDESTRIAN, AND VEHICULAR ACCESS TO BUILDINGS SHALL BE MAINTAINED AT ALL TIMES, EXCEPT WHEN PERMITTEE HAS PERMISSION FROM THE BUILDING OWNER AND THE DIRECTOR TO CLOSE AN ACCESS. E. ALL ROADWAYS SHALL BE KEPT FREE OF DIRT AND DEBRIS USING STREET SWEEPERS. USE OF WATER TRUCKS FOR CLEANING ROADWAYS REQUIRES PREAPPROVAL FROM THE DIRECTOR. F. INSTALL STEEL PLATES OVER ANY TRENCH, AT ANY TIME WORK IS STOPPED AND THE TRENCH IS LEFT OPEN. PROJECT NOTES 1. SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE PROJECT SPECIFICATIONS, THE 2008 WSDOT STANDARD SPECIFICATIONS, AND THE A.P.W.A. STANDARDS WHICH ARE HEREBY REFERENCED AS PART OF THESE PLANS. 2. THE DESIGN SHOWN IS BASED UPON .THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THE PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON THE SURVEY PREPARED BY PACE, DATED 06.30.2008. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION — NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. DRAWING INDEX SHEET NO. DRAWING TITLE CV -1 COVER SHEET D -1.0 DEMOLITION AND T.E.S.C. PLAN C -1.0 SITE PLAN C -11.1 LANDSCAPE ISLAND DETAILS CITY OF TUKWILA GENERAL NOTES 1. LOCATIONS SHOWN FOR EXISTING UTILITIES ARE APPROXIMATE. 2. AT LEAST 48 HOURS BEFORE STARTING PROJECT SITE WORK, NOTIFY THE UTILITIES INSPECTOR AT 206 - 433 -0179. 3. REQUEST A PUBLIC WORKS UTILITY INSPECTION AT LEAST 24 HOURS IN ADVANCE BY CALLING 206 - 433 -0179. 4. THE CONTRACTOR ASSUMES SOLE RESPONSIBILITY FOR WORKER SAFETY, AND DAMAGE TO STRUCTURES AND IMPROVEMENTS RESULTING FROM CONSTRUCTION OPERATIONS. 5. THE CONTRACTOR SHALL HAVE THE PERMIT(S) AND CONDITIONS, THE APPROVED PLANS, AND A CURRENT COPY OF CITY OF TUKWILA DEVELOPMENT GUIDELINES AND DESIGN AND CONSTRUCTION STANDARDS AVAILABLE AT THE JOB SITE. 6. ALL WORK SHALL CONFORM TO THESE APPROVED DRAWINGS. ANY CHANGES FROM THE APPROVED PLANS REQUIRE PRE — APPROVAL FROM THE OWNER, THE ENGINEER, AND THE CITY OF TUKWILA. 7. ALL METHODS AND MATERIALS SHALL MEET CITY OF TUKWILA DEVELOPMENT GUIDELINES . AND DESIGN AND CONSTRUCTION STANDARDS, UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DIRECTOR. 8. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF RECORD DRAWINGS ON —SITE. 9. CONTRACTOR SHALL PROVIDE RECORD DRAWINGS PRIOR TO PROJECT FINALAPPROVAL. 10. PROVIDE TRAFFIC CONTROL AND STREET MAINTENANCE PLAN FOR PUBLIC WORKS APPROVAL BEFORE IMPLEMENTATION. 11. ALL SURVEYING FOR PUBLIC FACILITIES SHALL BE DONE UNDER THE DIRECTION OF A WASHINGTON LICENSED LAND SURVEYOR. VERTICAL DATUM SHALL BE NAVD 1988. HORIZONTAL DATUM SHALL BE WASHINGTON STATE (GRID) COORDINATES, NORTH ZONE, USING NAD 83/91 SURVEY CONTROL AND TIED TO ANY TWO CITY OF TUKWILA HORIZONTAL CONTROL MONUMENTS. FOR PROJECTS WITHIN A FLOOD CONTROL ZONE, THE PERMITTEE SHALL PROVIDE CONVERSION CALCULATIONS TO NGVD 1929. 12. REPLACE OR RELOCATE ALL SIGNS DAMAGED OR REMOVED DUE TO CONSTRUCTION. 13. RETAIN, REPLACE OR RESTORE EXISTING VEGETATION IN RIGHTS —OF —WAY, EASEMENTS, AND ACCESS TRACTS. — REVIEWED FOR CODE COMPLIANCE j PROVE JUL 14 2010 City of Tukwila BUILDING DIVISION Know what's below. Call before you dig. . Z S 1505 Westlake Ave. N. Suite 305 Seattle, WA 98109 1 � T (206) 522 -9510 F (206) 522 -8344 WWW.PACLAND.COM REVISIONS CITY OF TUKWILA JUN 0 2010 PERMIT CENTER PERMIT 6/28/2010 NO. DESCRIPTION DATE THIS SURVEY GENERAL DEMOLITION NOTES CB = IE 12 "CONC(S)� CB RIM =2 2 " ONC(W IE ' "C.NC(N CONC(N)- \1 " DI(S DEMOLITION NOTES ARE FOR CLARIFICATION ONLY AND ARE SHOWN FOR THE CONTRACTOR'S BENEFIT. THESE NOTES ARE NOT INTENDED TO BE COMPREHENSIVE. THE CONTRACTOR SHALL REMOVE OR RELOCATE ALL EXISTING ON -SITE IMPROVEMENTS NECESSARY TO ACCOMMODATE THE PROPOSED CONSTRUCTION. ASPHALT CURB ' NE N OT A' PENDING`BINDING THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THE PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON THE SURVEY PREPARED BY APEX ENGINEERING, RECEIVED 6 -16 -2004. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND /OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE REUED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTIUTIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 4. CONTRACTOR IS TO REMOVE ALL EXISTING SURFACE IMPROVEMENTS AND DEBRIS WITHIN THE LIMITS OF WORK UNLESS OTHERWISE NOTED. ALL DEBRIS FOUND ON SITE SHALL BE DISPOSED OF IN ACCORDANCE WITH APPLICABLE STATE CODES. 30.00' U6p SDM : ti, =27. IE 12 "DI(N ) =19.3 __JE_12 "D1{ =19.3 ARE LAN' bor = COLUMN N .8 10 CONC (TYP) WALL d J 15 ES 'T "OW IMP 'OVMENTS CRT(L . 11 IT1ES REC. # 2007061 0,00339 , \ 8 IM 23. ),6 ,: 0 0 N N -15 O D Cn CD (n -J C/) w rz (-) Cn z 0 Cn x w J J 0 0 Y- (1.) c 0 a eri NOTES 1. ALL WORK AND MATERIALS SHALL . COMPLY WITH ALL CITY /COUNTY REGULATIONS AND CODES AND O.S.H.A. STANDARDS. 2. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE EXISTING CONDITIONS. THIS PLAN DOES NOT REPRESENT A DETAILED FIELD SURVEY. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE BASED UPON SURVEY PREPARED BY APEX ENGINEERING, RECEIVED 6 -16 -2004. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED SITEWORK IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITEWORK WHICH WOULD BE AFFECTED. IF CONTRACTOR DOES NOT ACCEPT EXISTING SURVEY, INCLUDING TOPOGRAPHY AS SHOWN ON THE PLANS, WITHOUT EXCEPTION, HE SHALL HAVE MADE, AT HIS OWN EXPENSE, A TOPOGRAPHIC SURVEY BY A REGISTERED LAND SURVEYOR AND SUBMIT IT TO THE OWNER FOR REVIEW. 3. CAUTION - NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND /OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS U11U11ES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBIUTY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES AND EXISTING IMPROVEMENTS WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS ON THE PLANS. 4. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND DIMENSIONS OF VESTIBULE, SLOPED PAVING, EXIT PORCHES, SIDEWALKS, RAMPS & TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. 5. DIMENSIONS SHOWN REFER TO FACE OF CURB, FACE OF BUILDING OR TO THE CENTERLINE OF PAVEMENT STRIPING, UNLESS OTHERWISE NOTED. 6. ALL PAVED PARKING LOT AREAS WITHIN THE LIMITS OF IMPROVEMENTS SHALL BE STANDARD DUTY PAVEMENT UNLESS OTHERWISE NOTED. 7. CONTRACTOR SHALL PROVIDE A TEMPORARY TRAFFIC CONTROL PLAN FOR THE CITY ENGINEER'S APPROVAL PRIOR TO ANY WORK WITHIN THE CITY RIGHT -OF -WAY. 8. FIRE LANE STRIPING AROUND BUILDING PERIMETER AND ALONG FIRE TRUCK ACCESS WAYS SHALL BE INSTALLED AS PART OF THIS CONTRACT, IN ACCORDANCE WITH THE LOCAL CODE AND FIRE MARSHALL REQUIREMENTS. 9. REFER TO BOUNDARY SURVEY FOR LEGAL DESCRIPTION, DIMENSIONS OF PROPERTY LINES, BASIS OF BEARINGS & BENCHMARK INFORMATION. (SEE SHEET CS -1) 11. ALL ON -SITE PAINTED STRIPING SHALL BE DOUBLE COATED. SEPARATE COATS SHALL BE APPUED NO SOONER THAN 4 HOURS APART. (CONTRACTOR TO REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL PAVING MARKING REQUIREMENTS.) 12. PARKING LOT STRIPING SHALL BE WHITE, 4" WIDTH, & DOUBLE COATED, UNLESS OTHERWISE NOTED. LIGHT POLE BASES TO BE PAINTED PER ARCHITECT'S DIRECTION. 13. ALL DISTURBED AREAS ARE TO RECEIVE FOUR INCHES OF TOPSOIL, SEED, MULCH AND WATER UNTIL A HEALTHY STAND OF GRASS IS ESTABUSHED. 14. ALL ISLANDS WITH CURB AND GUTTER SHALL BE LANDSCAPED. THOSE ISLANDS ARE TO HAVE 18" CURB AND GUTTER. ALL REMAINING ISLANDS ARE TO BE STRIPED AS SHOWN. 15. EXISTING STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE ABANDONED, REMOVED OR RELOCATED AS NECESSARY. ALL COST SHALL BE INCLUDED IN BASE BID. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, INCLUDING BUT NOT LIMITED TO ALL UTILITIES, STORM DRAINAGE, SIGNS, TRAFFIC SIGNALS & POLES, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BASE BID. Know what's below. Call before you dig. 40 0 IE 12 "CONC(S) 25 ��CB RIM =2 • 2 ONC(W IE "C•NC(N = CONC(N)- \1 " DI(S THIS SURVEY APPX. )c-. - • FROM S. CENTER UTILITIES PLAN SITE KEY GUTTER =1 s NE r NLOT A ' PENDING °IND!NG CB RIM 22.82 NC E) 20.8 . #: . 2 .47 MH_'1M= T .25- HA 10" /W /S) -16.0 _cs_ -------- __ _,/ UGp SDMH E lM =27. IE 12 "DI(N N) =19.3 ___JE_1.2".D1( ) =19.3 W) 13.2 30.00' 15 ES 'T " OW IMP R0 ENTS ti 1 LIT ES REC. # 2007061 00339 ■ FIRE_ LAND. SS Nit/ %11.1/174 FF =28.8 COLUMN 10' CONC (TYP) WALL B -1M- -23.6 E • CO C( )= 2.1 K DRAIN 14' CONC WALL '.3 CB RIM =27.54 IE 12 "CONC(N) =23.2 IE 10 "CONC(S) =23.2 -2=' °SEAFOOD crr F5 .23.3 :24.3 3 YD RIM =28.60 IE 8 "PVC(S) =26.4 YD RIM =28.63 IE 8 "PVC(S) =26.3 FFE 28.8 16" PLU COLUMN (TYP) FF =28.8 COLUMN (TYP) YD RIM =28.67 IE 8 "PVC(W) =26.5 CONC CURB 10" 0 FF =28.8 YD RIM= 28.64 IE 8 "PVC(W) =26.5 YD R1M =28.65 1E 8 "Cl (W) =26.7 RED RIBBON FF =28.8 ASPHALT FND. CA ED . BRASS CAP FF =28.8 CB RIM =27.73 IE 24 "CONC(E) =20.8 IE 18 "CONC(S) =20.8 NOTE: UNABLE TO DETERMINE IF PIPE TAPERS (E) TO 12" DIAMETER. GAS ALCOVE (SEE ARCH PLANS \i F, `2M =23.19 IE 12 "COCBN \(lW) =16.3 METER BOX IE 12 "CONGA(\) =16.3 CONCRETE CURB LANDSCAPE ISLAND, (TYP) SAWCUT, MATCH AND JOIN EXISTING PAVEMENT PAVEMENT NOTES LEGEND STANDARD DUTY PAVEMENT CONCRETE CURB SAWCUT ISLAND DETAIL, SEE SHEET C -1.1 K 1. MATERIAL THICKNESS IS COMPACTED DEPTH. APPLIES TO ALL SECTIONS. 2. SUITABLE ONSITE SOILS SHALL BE FREE OF DELETERIOUS MATERIALS AND MAY BE USED FOR SUBBASE PROVIDED SOILS MEET REQUIREMENTS IN THE PROJECTS SPECIFICATIONS. 3. FOR PREPARATION OF PAVEMENT SUBGRADE, FILL PLACED WITHIN 12 INCHES OF FINISHED SUBGRADE ELEVATION IN FILL AREAS AND AT LEAST THE UPPER 8 INCHES OF SUBGRADE IN ALL AREAS TO BE PAVED SHOULD BE COMPACTED TO AT LEAST 98% OF THE MATERIAL'S MAXIMUM STANDARD PROCTOR DRY DENSITY (ASTM D -698). FILL PLACED BELOW THIS LEVEL SHOULD BE COMPACTED TO AT LEAST 95% OF THE MATERIAL'S MAXIMUM DRY DENSITY. 4. AFTER PROOFROLLING WITH A LOADED TANDEM AXLE DUMP TRUCK AND REPAIRING DEEP SUBGRADE DEFICIENCIES, THE ENTIRE SUBGRADE SHOULD BE SCARIFIED TO A DEPTH OF 8 INCHES AND UNIFORMLY COMPACTED TO AT LEAST 98% OF STANDARD PROCTOR. 5. CRUSHED BASE COURSE MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF SECTION 9- 03.0(3) OF THE WSDOT STANDARD A� SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. 6. ASPHALTIC SURFACE COURSE MIXTURES SHALL BE IN ACCORDANCE WITH SECTION 9 -02, GRADE B OF THE WSDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THE MIXTURE SHALL HAVE A MINIMUM MARSHALL STABILITY OF 1,000 POUNDS, AND THE SURFACE COURSE SHOULD BE COMPACTED TO A MINIMUM OF 97% MARSHALL DENSITY (ASTM SPECIFICATION D 1559). 7. THE PORTLAND CEMENT CONCRETE PAVEMENT MIXTURE SHALL BE IN ACCORDANCE WITH AIR-ENTRAINED CONCRETE FOR PAVEMENT SECTIONS 501, 551, AND 701 OF THE WSDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. THE MIXTURE SHALL BE DESIGNED TO DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS WITH A 4 INCH MAXIMUM SLUMP AND 5 TO 7% ENTRAINED AIR. 8. CONTRACTOR SHALL PROVIDE A PRIME COAT AND TACK COAT TO FACE OF CURB WHERE CURB CONTACTS ASPHALT. 9. PAVEMENT SECTIONS PER SHANNON WILSON RECOMMENDATION VIA EMAIL DATED APRIL 18, 2006. ASPHALT CONCRETE SURFACING (GRADE 'B' - WSDOT SECTION 5 -04.) t 11" PLU c 1 5" DEC ASPHALT FF =28.8 BIKE RACK EXISTING BRICK LANDSCAPE COLUMN ISLAND SDM RIM =27.57 IE 1 "CONC(N) =20.6 IE 19'CONC(E) =20.4 IE 12E'CONC(S) =20.7 D RSA= ..1 IE 15 "CONC(W) =16.7 IE 24 "CONC(E) =15.7 IE 12 "CONC(S) =18.9 FF =28.8 BRICK COLUMN 30 GRAS FF =28.8 CONC CURB ' 10' UTILITY EASEMENT A F.N'SS. 999.00 AND 0170 `y7. 16" PL FF =28.8 GRAP}B(= S��NEY 20 40 80 L. , 4. 1(1 NEW LOT A , ( IN FEET ) 1 inch = 40 ft. 160 ■ FF =28.8 A/ 7+:r�, 1 15' 31 U I11' " 1 E. 1 J 3 "PLUM ENTS 20* 061'000339 UTILITY VAULT ASPHALT 1 a c CRUSHED BASE COURSE ( WSDOT STD SPEC 9 -03.9 (3)) btOLt7 COMPACTED GRANULAR FILL CONFORMING TO WSDOT GRAVEL BORROW (SECTION 9.03.14(1)) COMPACTED SUITABLE NATIVE MATERIAL OR STRUCTURAL FILL. UNSUITABLE NATIVE MATERIAL SHALL BE OVEREXCAVATED AND REPLACED. SUBGRADE SHALL BE PREPARED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS TO ACHIEVE 95% OF MAXIMUM DRY DENSITY (ASTM D1557). STANDARD DUTY PAVEMENT NOTES: 1. EXPANSION JOINT: PLACE AT ENDS OF ALL RADII, 5' ON EACH SIDE OF DRAINAGE STRUCTURES, AND AT 45' MAX. INTERVALS IN CURB. PROVIDE #6 x 18" LONG SMOOTH STEEL DOWEL BARS WITH 11'0 GREASE CAP THROUGH EXPANSION JOINTS. (3" THICK BITUMINOUS FILLER MATERIAL). 2. CONTRACTION JOINT: PROVIDE 2" DEEP x Y" WIDE CONTRACTION JOINTS AT 15' INTERVALS. 3, REMOVE FORMS AS EARLY AS POSSIBLE. BRUSH TOP AND FACE OF CURBS TO REMOVE ALL IMPERFECTIONS. TYPICAL OF ALL FORM WORK. 4. ALL RADII SHALL BE TRUE ARCS. LIGHT BROOM FINISH ON ALL EXTERIOR CONCRETE. REVIEWED FOR CODE COMPLIANCE App3 f En JUL 14 2010 NTS ELASTOMERIC SELF - LEVELING SEALANT AT PAVEMENT /CURB TRANSITION. ASPHALT PAVING BASE COURSE WITH PRIME COAT (PER PAVEMENT SECTION) SUB -GRADE PER SOILS REPORT 1 "R Co Q° o 0 co, o 0 • // o / O o o0p O O o //\\ /000 O o O o 0 0 D c a \ O o po p °° O v °a °o0oo;" o °�ooi - *8 " AT HEAVY \- / \moo oo d- DUTY SECTION PRIVATE ON-SITE STRAIGHT CONCRETE CURB v ' • O • • v • acs t"- RECEIVED CITY OF TUKWILA JUN 0 2010 PERMIT CEN Date Revision D.escrij 6 -28 -2010 PACLAND PERMIT SUBMITTAL :.. ,. �..' ._.'a, . 1.- - .>_.. .... ? _J..:, . -.. :•• .- ':iii. >L •n".- _ _ 1505 Westlake Ave. N. Suite 305 4 .28 . /0 Seattle, WA 98109 T (206) 522 -9510 F (206) 522 -8344 WWW.PACLAND.ODM City of Tukwila BI!I ill lC- 6 11/1 ' ,lj.f l LANDSCAPE REVISIONS SOUTHCENTER MALL TUKWILA, WASHINGTON NTS SITE PLAN C -1.0 ■ . "/ p8 00 g)00° 0 00 -pb° 0 ° i o o 0 0 0 ;�go0o°p ° 0o° o O. ° o p 000 0 00 o 0 ° o D° %„,0.4> ° o oc� 0 0° o o 0 or CRUSHED BASE COURSE ( WSDOT STD SPEC 9 -03.9 (3)) btOLt7 COMPACTED GRANULAR FILL CONFORMING TO WSDOT GRAVEL BORROW (SECTION 9.03.14(1)) COMPACTED SUITABLE NATIVE MATERIAL OR STRUCTURAL FILL. UNSUITABLE NATIVE MATERIAL SHALL BE OVEREXCAVATED AND REPLACED. SUBGRADE SHALL BE PREPARED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS TO ACHIEVE 95% OF MAXIMUM DRY DENSITY (ASTM D1557). STANDARD DUTY PAVEMENT NOTES: 1. EXPANSION JOINT: PLACE AT ENDS OF ALL RADII, 5' ON EACH SIDE OF DRAINAGE STRUCTURES, AND AT 45' MAX. INTERVALS IN CURB. PROVIDE #6 x 18" LONG SMOOTH STEEL DOWEL BARS WITH 11'0 GREASE CAP THROUGH EXPANSION JOINTS. (3" THICK BITUMINOUS FILLER MATERIAL). 2. CONTRACTION JOINT: PROVIDE 2" DEEP x Y" WIDE CONTRACTION JOINTS AT 15' INTERVALS. 3, REMOVE FORMS AS EARLY AS POSSIBLE. BRUSH TOP AND FACE OF CURBS TO REMOVE ALL IMPERFECTIONS. TYPICAL OF ALL FORM WORK. 4. ALL RADII SHALL BE TRUE ARCS. LIGHT BROOM FINISH ON ALL EXTERIOR CONCRETE. REVIEWED FOR CODE COMPLIANCE App3 f En JUL 14 2010 NTS ELASTOMERIC SELF - LEVELING SEALANT AT PAVEMENT /CURB TRANSITION. ASPHALT PAVING BASE COURSE WITH PRIME COAT (PER PAVEMENT SECTION) SUB -GRADE PER SOILS REPORT 1 "R Co Q° o 0 co, o 0 • // o / O o o0p O O o //\\ /000 O o O o 0 0 D c a \ O o po p °° O v °a °o0oo;" o °�ooi - *8 " AT HEAVY \- / \moo oo d- DUTY SECTION PRIVATE ON-SITE STRAIGHT CONCRETE CURB v ' • O • • v • acs t"- RECEIVED CITY OF TUKWILA JUN 0 2010 PERMIT CEN Date Revision D.escrij 6 -28 -2010 PACLAND PERMIT SUBMITTAL :.. ,. �..' ._.'a, . 1.- - .>_.. .... ? _J..:, . -.. :•• .- ':iii. >L •n".- _ _ 1505 Westlake Ave. N. Suite 305 4 .28 . /0 Seattle, WA 98109 T (206) 522 -9510 F (206) 522 -8344 WWW.PACLAND.ODM City of Tukwila BI!I ill lC- 6 11/1 ' ,lj.f l LANDSCAPE REVISIONS SOUTHCENTER MALL TUKWILA, WASHINGTON NTS SITE PLAN C -1.0 SLANDS \2DWGS \TUL S: \Washington \TUKWILA \Westfield \O NORTH MALL EXPANSION \LANDSCAPE THIS SURVEY APPX. IE 12 "CONC(S) CURB &' GUTTER 8.69' c• suc NE .LOT A PENDING \BINDING PROVE ENT TE PLAN c CB ' IT422.82 IE 12 "9NC(N) =1gA 1E J cONC(s)= =1`,\ CB RIM 22.82 NC E »20.8 /S =1`2 ASP ALT RI 23\47 C W) 13.2 NC \) 7.1 Q �(°' 15 ES 'T "0 W IMPR ,A 30.00' FACE BACK LANDS CURB --" CURB -N, PE cV cri MATCH EXISTING NGLE LANDS APES FACE OF CURB BACK OF CURB FACE BACK OF CURB -7 OF CURB ---' 2.4 LANDSCAPE ENTS gC t T1 J11ES REC. # 20070618],00339 B IM 23. CO •I C( POWER VAULT TO REMAIN 6 ,' 15' 2.1 ,' 8.12' FF =28.8 COLUMN 10' CONC (TYP) WALL CB RIM =27.54 IE 12 "CONC(N) =23.2 IE 10 "CONC(S) =23.2 "u1 °SEAFOOD CITY b5 .23.3 :24.3 3 DRAIN 14' CONC WALL K YD RIM =28.60 IE 8 "PVC(S) =26.4 YD RIM =28.63 IE 8 "PVC(S) =26.3 FFE 28.8 SSMH RIM =27.48 CL CHAN 10" (N S) 8 "(NW) =14.9 IE "C+ IE 12 "C LANDSCAPE ISLAND LANDSCAPE ISLAND LANDSCAPE ISLAND N.T.S. N.T.S. 16" PLU COLUMN (TYP) FF =28.8 COLUMN (TYP) YD RIM =28.67 IE 8 PVC(W) =26.5 CONC CURB 5;91812 TEL PH'NE CO. EASEMEN ASPHALT N.T.S. Cr) C) P LLI FF =28.8 YD R1M =28.64 IE 8 "PVC(W) =26.5 YD RIM =28.65 IE 8 "CI (W) =26.7 RED RIBBON FF =28.8 FACE OF CURB -7 BACK OF CURB 5'R 1 58' LAND CAPE ASPHALT R MA XISTITCH NG 4 . LE reAlk 5R 1'R 6.65' FF =28.8 CB RIM =27.73 IE 24 "CONC(E) =20.8 IE 18 "CONC(S) =20.8 NOTE: UNABLE TO DETERMINE IF PIPE TAPERS (E) TO 12" DIAMETER. Know what's below. CaII before you dig. JC PENNEY FF =28.8 BIKE RACK BRICK COLUMN FF=28.8 BRICK COLUMN 11" PLU CB"17IM =23.19 IE 12 "CONt(W) =16.3 METER BOX IE 12 "CONC E) =16.3 10" OA F CURB -7 F CURB FACE BACK F CURB F CURB 1.8f LANDS APE C< 5" DEC LANDSCAPE ISLAND N.T.S. LANDSCAPE ISLAND N.T.S. SDM RIM =27.57 IE 1; "CONC(N) =20.6 IE 1; CONC(E) =20.4 IE 12i CONC(S) =20.7 R = 4.1 IE 15 "CONC(W) =16.7 IE 24 "CONC(E) =15.7 C� IE 12 "CONC(S) =18.9 r V •-.) L./ 30 GRAS F CE of CURB -7 B CK F CURB FACE r CURB BAC `. CURB BUG FF =28.8 FF =28.8 FF =28.8 UTILITY VAULT ASPHALT 1 .CONC CURB s\ 10' UTILITY EASEMENT A F.N' . 5,999 00 ' ND 7.901070 (11 NEW LOT A j .11 , "4a 7 tZp SM' R iE # 16" PL 3 °PLUM / 1 RO ENTS 2a 061)000339 LANDSCAPE ISLAND 1 ASPHALT N.T.S. 1 I L NDS APE V)EWED FO CODE COMPLIAN E Aoto pp X1'4 2010 eo City of Tukvvila LANDSCAPE ISLAND FACE BACK F CURB - F CURB 1.82' BUILDING DIminru N.T.S. 1'R MATCH EXISTING ANGLE 90• 8.23' • n CO 1'R EIV D CITY REC OF TU WILA JUN 5 0 2010 PERMIT CENTER LANDSCAPE ISLAND LANDSCAPE ISLAND. N.T.S. VISION N0.1 ors ."7 i -.. .1 s T+'., S r- . P. r,. . S. i 3",+ Z x 9 s: p '�'. �2 a% ... - - ..,...... z -':a, w <..- a_:... / ss.. ..c.i..;.h:ro...z lx..s.s sr .r.....,..... ..<.. <-r .n. . ......- ss,. „_..s....- .. .L_......: u,.. ;<..�..u....':�..: <.>c. .'.._.':.r.....>._...- <a...>G )w.: .... ✓, v.,.+.::., r,:... »�...:... /. 7 c�.... w- s. ......:._..�.>. «...<. ✓.r..:.... . <'>u...r _....�..,z .�:.� ..u.._. ... �. .r. ....r .,_ ..,✓..., n+.....,. _x.....c.._.4�.._?rr..- ....�. <. �.r.,.4..<.- ...ca,.. ,wc v...<�.,..a�..........n....<oa ...... ,.....- ...- ...✓a,... ._.... Date 6 -28 -2010 PACLAND n.. PERMIT SUBMITTAL 6 -15 -2010 PERMIT 1505 Westlake Ave. N. Suite 305 G . . /b Seattle, WA 98109 T (206) 522 -9510 F (206) 522 -8344 WWW.PACLAND.COM LANDSCAPE REVISIONS SOUTHCENTER MALL TUKWILA, WASHINGTON tkov4b1r7 LANDSCAPE ISLAND DETAILS ■ ■ C -1.1 Plotted: Apr 21, 2008 — 12:38pm 8 -'BLUE STAR' JUNIPER (2 LOOS. ) 5- 13EARBERRY COTON ASTER 7 ' ► AGIC CARP SPIREA (2 LO 1 -'BAY BREEZE' R1 -1A-P IDLE -PI ////////// GREENSPI LINDEN 5 -BEARS RRY COTON STER 7 'SOFT TOUCH' HOLLY (2 LOCS. 7 'MAGIC CARPET' SPIREA (2 LOCS.) - 'GREENSPI ' E' LINDEN EXLCAN FEA HER GRAS 3 -'M AIRY' FOTHI'GI LLA 1 1 1 1 11 / , 1 1 1 1 1 1 1 1 1 8 'BLUE STAR' JUNIPER (2 LOCS. ) 1- ATSURA T°EE - BEARBER- COTONEAS ►ER 2 'MAGI CARPE ' SPIREA 3 ' TELLA D'0-0' D• LILY -'SAY BRED E' RHAPHIOL IS - KATSURA TREE 1 XI CAN FED ER- GR-ASS VIEW A 4 'BLUE STAR' JUNIPER (2 LOCS. ) 3- 13 EARBERRY COTON EASTER 'GREENS-IRE' LINDE 1 'BAY BREE R • PHIOLEPIS 2 'S LLA D'ORO DAYLI L 3 -'MAGI CARPET' S °IREA 4 'MAGIC CARPET' IREA (2 LVCS.) 5 'SOFT TOUCH' HOLLY 1 MEXIC • FEATH GRASS UE STAR U IPER - 'GREENSPI r E LINDEN 4- BEARBERRY COTON EAST ER 2 'MAC C CARPET' PIREA 1 KATSUR• TREE 'BAY BRE = E' R • PHIOLEPIS DAYLI . Y 3 -BEAR ERRY COTON EA TER 10 -DWARF H S W EETBOX MALAYAN -'BLUE STA'' JUNIPER 5- EVERGRE IEN CLEMATIS EXCAVATE PLANTER TO 18" DEPTH, DISPOSE MATERIAL OFF -SATE AND BACKFILL WITH AMENDED TOPSOIL. T BOG VENT 4 'MAGIC CARPET' EA (2 LOGS. ) o_ c_-`. - 1 KATS CA URA TREE' MEXI FEATHER �'AS' IRE HYDRANT VIEW B Pe/m alb ThAta5 Pr feel, ffro o- � b VIEW A a 1 777 A a VIEW B VIEW C , o- �� � \, \ \, \ \,q, \ \\ e► e► a <r t) 0 0 z <1 KEY PLAN N TS SkEET NOTES 1. Refer to details and specifications sheet L -3 for additional information. 2. No plant substitutions shall be permitted without prior approval of Landscape Architect /Owner. 3. All work shall be performed to the satisfaction of the Landscape Architect /Owner. 4. Plant list quantities are shown for reference only. Contractor is responsible for verifying all quantities in list with actual plan call —outs, and installing plantings per the landscape plan. Groundcover quantities shall be adjusted as required for field conditions at the specified spacing. 5. All plants must be approved by Landscape Architect or Owner's representative prior to installation. 5- 'MAGIC CARPET' SPIREA (2 LOCS.) 5- BEAR5ERRY COTON ST ER - 'BLUE " AR' JUNIPE 2_LOCS )_ EENSPIRE LINDEN 1 'BA BREEZE' RHAPHI LEPIS 3 'STELLA ORO' AYLI LY 2 'SLUE STAR' JUNIPER q 'SOFT TOUCH' HOLLY ( LOGS. ) 2 'MT. Al FOTHER LA 1 MEX AN FEA ER-GRASS REENSPIRE' LINDEN 'MAGIC CQ,RPET' SPUR' A VIEW C REVISION N0:1 b10`11`1 i3l06/pW'// /1 REVIEWED FOR CODE COMPLIANCE riVE JUL 14 2U10 City of Tukwila BUILDING niviSinM ST WAS REG LANDSCA TE OF TON RED RCHITECT Cer ander No. 405 RECEIVED ITY DF TIIKWILA JUN ',)02010 N OR T 0 10' SCALE: 20' 1 "= 10 -0" 30' N ♦' 0 -0 c 0 > a) L O c 10 -0601 job no. RK drawn TLG /JBG checked 0 03 o�N 0 w 0 0 H IOW Architecture Site Planning lympia, WA 98506 www.glanderassociates.com LAI sheet L 1 of 3 Plotted: Aor 21 2008 — 12:38em / OPERATION /PRESSURE INDICATOR STAKE - SEE DETAIL AND EQUIPMENT LIST SWEET L -3 FOR MORE INFORMATION. 0 0 0 • • 3/411 r, OrO��rb 00 0 0 • • 1.1 GPM 161 SF. 11'2" SL. ==> 000.0• 3/411 0 0 0001• • 0 0 O ° 0 • Plan is diagrammatic. Place all pipe, laterals and wire in landscape beds where appropriate. 0 • SAN CUT EXISTING ASPHALT. BACKFILL SLEEVED PIPE PER DETAIL TI-119 SWEET. (TYP.) 0 0 0 0 1.0 GPM 152 SF. 11/2" SL. 0.7 GPM/ 100 SF. SAN CUT EXISTING ASPHALT. SACKFI LL SLEEVED PIPE PER DETAIL THIS SWEET. (TYP.) VIEW A 11 0.5 GPM 75 SF. 0 Plan is diagrammatic. Place all pipe, laterals and wire in landscape beds where appropriate. SAN CUT EXISTING ASPHALT. BACKFILL SLEEVED PIPE PER DETAIL T1-119 SHEET. (TYP.) 1'12' 1 SL. 0 0.2 GPM 31 SF. S1-IF E T NOTES 1. See equipment list, details and specifications sheet L -3 for additional information. 2. Plan is diagrammatic. All piping, laterals, and wire to be located in bed or lawn areas where appropriate. 3. Pipe sizes are to remain constant between pipe size call —outs. 4. All irrigation heads located in lawn areas shall be 4" pop —ups and heads in shrub areas shall be 12" pop —ups. 5. Locate all mainlines within the project limits. 6. All work shall be performed to the satisfaction of the Landscape Architect /Owner. ASPHALT WITH EMULSIFIED ASPHALT IN SEAL. MATCH SURROUNDING ASPHALT DEPTH. FINISH GRADE EXISTING ASPHALT . /Al* ,. - ► 4`` :':.: 474,1,04ArGo yrt 0. wotSpliz r.o..-10 %" MINUS CRUSHED GRAVEL 6" MIN CLEAN SAND 6" MIN CLEAN SAND 11 EXISTING SUBGRADE 6" MIN CLEAN SAND PVC IRRIGATION PIPE IN SLEEVE 6" MIN CLEAN SAND PIPE UNDER EXISTING PAVED AREAS 0.3 GPM 41 SF. NEN CONTROLLER MOUNTED TO EASTERN ALCOVE HALL. GENERAL CONTRACTOR SHALL PROVIDE POWER AND CONDUIT TO NEAREST LANDSCAPE BED. 3/411 0.5 GPM 75 SF. /// 611 Si_ 0.1 GPM 16 SF. SAN CUT EXISTING ASPHALT. BACKFILL SLEEVED PIPE PER DETAIL THIS SHEET. (TYP.) 11,211 SL. 6.c1 GPM J 1 ■ ■ 3/411 x PEAT BOG VENT Fl E HYDRANT /411 II( 3411 0.6 GPM EA SF. \/ 11/211 L. P.O.C. CO EXISTING MAINLINE. LANDSCAPE \ / CONTRACTOR SHALL FIELD VERIFY SIZE AND PRESSURE AND NOTIFY LANDSCAPE ARCHITECT IF PRESSURE IS LESS THAN 30 PSI. / VIEW B NTS // VIEW A U 0 0 LJ (V/ O// /// ..11111111 //b VIEW B Tukwila n i 110 \\ \ \ \ \ \ \\4 VIEW C , a 11 ®��.j�� / / / / / / / / / //) II \ \ \ \ \ \ \`N, \ \ \ \ \ \ \\ r=- 0 ( • KEY PLAN NTS City of Plan is diagrammatic. Place all pipe, laterals and wire in landscape beds where appropriate. OPERATION /PRESSURE INDICATOR STAKE - SEE DETAIL AND EQUIPMENT LIST SHEET L -3 FOR MORE INFORMATION. 3/411 11/2" SL. 000 0 °0 0 0 0 0 0 • • • Al 11 0.8 GPM 113 SF. 11/2 " SL. 11 SAN CUT EXISTING ASPHALT. BACKFILL SLEEVED PIPE PER DETAIL TI-119 SWEET. (TYP.) 0.1 GPM 20 SF. 11 0.3 GPM 52 SF. VIEW C REV1SIOMNO __ 1_ bk0 tt7 �Y Tukwila REVIEWED FOR CODE COMPLIANCE APO ii nvED JUL 14 2010 � ST WA RE LANDSCA J_cIT\RLA BUILDING nniicinm u JUN 5 0 2010 N O R T� pERMITCENTER TE OF GTON RED ARCHITECT Glander e No. 405 10' SCALE: 20' 30' 1"=1 C-0" N 0 V c 0 a) L. O c 10 -0601 job no. RK drawn TLG /JBG checked 06/28/10 date W 1111. 0\ ture Site Planning www.glanderassociates.com Landscape Architect Avenue E. Olympia, WA 98506 ph. (360) 357 -6972 fx. (360) 786 -8073 N sheet L -2 of 3 s a END -FEED LAYOUT MANUAL DRAIN VALVE (TYP.) - INSTALL AT EXHAUST HEADER LOW POINT(S) IN EACH SUB -ZONE DRIPLINE - EVENLY SPACED (SEE EQUIPMENT LIST) COMPRESSION TEE 4-k--- SCH 40 PVC MAINLINE REMOTE CONTROL VALVE WITH FILTER CENTER -FEED LAYOUT CLASS 200 PVC LATERAL (SIZE PER PLAN) SUB -ZONE PERIMETER PERIMETER LATERALS 2" TO 4" FROM SUB -ZONE PERIMETER (TYP.) PVC LATERAL TO CENTER- /END -FEED CONNECTIONS (SEE DETAIL) PVC ELL PVC SUPPLY HEADER DRIPLINE 3'4" PVC EXHAUST HEADER (TYP.) NOTE: 1. Driplines shall be installed perpendicular to slopes. 2. In the upper % of slopes, space driplines at spacing indicated in equipment list. In the lower )5 of slopes, increase distance between rows by 25 %. 3. If elevation change in a zone is over 4i feet, landscape contractor shall either: a) Split the slope into separate zones, or b) Install in -line check valves for every 4) feet of elevation change. DRIPLINE SUB -ZONE LAYOUT 2" BARK MULCH 2" BELOW MULCH FINISH GRADE POLY COMPRESSION TEE NTS 6" VALVE BOX (INSTALL PER SPECS) BLANK DRIPUNE TUBING 3/4" GRAVEL SUMP (1 CUBIC FOOT) MANUAL DRAIN VALVE DRIPUNE EXHAUST HEADER MANUAL DRAIN VALVE BRICK SUPPORTS (THREE) FOR DRIPPERLINE DRIPLINE EMITTER TUBING (TYP.) - SEE EQUIPMENT LIST BLANK DRIPLINE TUBING DRIPLINE 3/4" MALE ADAPTER PVC SUPPLY HEADER W/ PVC FITTING LATERAL TO CENTER - /END -FEED DRIPLINE CONNECTIONS PVC EXHAUST HEADER W/ PVC FITTING FINISH GRADE 6" LOCKABLE VALVE BOX CONNECT TUBING TO TECHLINE 1" BRICK SUPPORTS (THREE) • INSTALL PEA GRAVEL SUMP (APPROX. 6" DEPTH) • o rd OPERATION /PRESSURE INDICATOR STAKE NTS QUICK COUPLER FINISH GRADE LOCKABLE VALVE BOX 2- STAINLESS STEEL WORM - GEAR CLAMPS NTS CURB OR EDGE (TYP.) SCH. 80 PVC NIPPLE LENGTH AS REQUIRED SCH. 40 PVC COUPLING SCH. 80 PVC NIPPLE SCH. 40 PVC ELBOW 2 -SCH. 40 PVC 90° STREET ELLS 1/2" DIAMETER STEEL ROD - 30" LENGTH SCH. 40 PVC MAINLINE FITTING SCH. 80 PVC NIP. QUICK COUPLER VALVE NTS NTS NOTE: ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO "IN -UNE" WIRE SPLICES ALLOWED. TAPE AND BUNDLE WIRES EVERY 20 FEET. PROVIDE EXPANSION COILS AT EACH VALVE - WRAPPING WIRE AROUND 1/2" PIPE 15 TIMES. ALL THREADED CONNECTIONS SHALL BE MADE WITH TEFLON TAPE. 6" MIN. - CLEARANCE SCH. 80 PVC NIPPLE SCH. 40 PVC & FITTING REMOTE CONTROL VALVE W/ PRV 12" x 18" VALVE BOX PVC SCH 80 COUPLER 150 MESH SELF- CLEANING BACKFLUSH FILTER ADJUST EQUIPMENT TO PROVIDE 2" MINIMUM CLEAR SCH. 80 PVC NIPPLE, LENGTH AS REQUIRED CO DEPTH ARSE GRAVEL 04.0_ 4p coo ql,,q� SCH. 40 PVC FITTING \ PVC MAINLINE DRIP REMOTE CONTROL VALVE LATERAL PIPE TO SPRINKLERS '-BRICK SUPPORT (1- EA. CORNER) LANDSCAPE SPECIFICATIONS 1. Refer to details for additional information. 2. Chemically kill and remove from site all existing weeds and vegetation not shown to remain on plans. 3. Distribute imported sandy loam topsoil (approved by the Landscape Architect) in areas shown and at depths indicated for crowning and berming of landscape areas, and backfill of retaining walls (if required). Dotted lines indicate 1' contour intervals. All landscape areas shall receive topsoil, whether indicated on plans or not, so that finish grades of all shrub beds shall be 2" below tops of adjacent curbs and pavement, and lawn areas shall be 1 2" below to's of jacen cures an pavemen ruc Ira 1 areas: Any andscape areas occurring within r structural fill zones shall have' said structural fill materials excavated to a depth of 12" below finish grades in shrub areas, and 6" below grade in lawn areas, and replaced with specified topsoil. Dispose of excavated material off site. 4. Fine grade all landscape beds prior to planting operations. 5. No plant substitutions shall be permitted without prior approval of Landscape Architect /Owner. 6. All plants shall conform to the latest edition of the American Standard for Nursery Stock. 7. All plant materials and plant locations shall be approved by the Landscape Architect prior to installation. All plants shall be thoroughly watered immediately after planting with Alaska Fish Fertilizer solution. 8. Root barrier shall be incorporated adjacent and parallel to paving, curb and sidewalk, a minimum of 15 linear feet (7.5' on either side of trunk), 24" deep, where any tree is within 6' of paving, curb or sidewalk. Root barrier shall be DeepRoot UB -24 as available from Ewing Irrigation Products, 2901 S Tacoma Way, Tacoma, WA 98409 (253) 476-9530 or approved equal. 9. Soil amendment for soil preparation and planting backfill shall be a screened 5/8" minus nitrified wood residual compost equal to: A. "Compost Plus" brand compost as available from South Sound Soils, Tenino WA (360) 273 - 8862. B. "Groco" brand compost as available from Sawdust Supply Co., Seattle, WA (206) 622 -4321, or Great Western Supply, Olympia, WA. (360) 754 -3722. C. PREP /LRI compost as available from Randels Sand and Gravel, Inc., Puyallup, WA (253) 537 -6828. 9. Soil Preparation - (all landscape areas). Spread 9 c.y. of specified soil amendment per 1000 s.f. (approx. 3" depth) of area. Spread 100 lbs. /1000 s.f. of dolomite lime (in lawn areas only), 150 lbs. /1000 s.f. of Agricultural Gypsum and 15 lbs. /1000 s.f. of 16 -8 -8 commercial fertilizer over soil amendment. Roto -till all of the above to a 6 " -8" depth and grade smooth, compacting as required and removing all rocks, clods and debris. 10. Backfill mix for all plants shall be a blend of 1/3 existing site soil, 1/3 coarse sand, and 1/3 soil amendment specified in No. 8. 11. Apply Osmocote 18 -6 -12, 9 month slow release fertilizer over the surface of all plant pits at the following rates: Trees Over 10' Height All Shrubs Except 1 Gallons: Ground Covers: 2 Cups 1/2 Cup 1/4 Cup Trees Under 10' Height: 1 Cup 1 Gallon Plants: 1/4 Cup 12. Fertilizer tablets for all plants shall be Agriform (20 -10 -5) 21 gram or 10 gram tablets distributed as follows: All trees: 4 -21 gram tablets, all shrubs (except 1 gallons): 3 -21 gram tablets, all 1 gallons: 1 -21 gram tablet. Set tablets directly next to rootball. 13. All shrub and ground cover beds shall receive a 2" depth (6 c.y. per 1000 s.f.) of "Fine Grind" hem /fir bark mulch as top dressing. 14. Apply a granular pre- emergent herbicide to all shrub and groundcover beds at the conclusion of the maintenance period. Do not use Casaron or Norasac Brands. 15. All work shall be performed to the satisfaction of the Landscape Architect /Owner. 16. All plants shall be guaranteed for one full year from date of project acceptance. All replaced plants shall be re- guaranteed. All replacements shall be made within 21 days of receiving written notice from the Owner. Contractor shall not be responsible for plants dying due to Owner neglect or vandalism, after the maintenance period. 17. Plant list quantities are shown for reference only. Contractor is responsible for verifying all quantities in list with actual plan call -outs, and installing plantings per the landscape plan. Groundcover and /or mass shrub quantities shall be adjusted as required for field conditions at the specified spacing. 18. Final inspection shall occur at the conclusion of a 60 -day maintenance period. Maintenance period shall commence upon completion of all landscape installation activities and shall include the following: A. B. C. D. Remove all weeds over 1" in height. Replace dead or unhealthy plants. Ensure proper function of irrigation system. Ensure adequate moisture is delivered to all landscape beds including non - irrigated areas. FINISH GRADE (INCLUDING BED MULCH) WIDTH VARIES 2" ® SHRUB BEDS, zFEEMItk. ASPHALT PAVING REFER TO PLAN 3" MIN.; REFER TO PLAN FOR SPECIFIC * BERM & CROWN HTS. AM Ali 4IIII1IIIIIIIIM IIIIIIIIIIIIIIIIIIIII CONCRETE CURB OR ADJACENT PAVEMENT NOTE: GENERAL CONTRACTOR SHALL REMOVE EXCESS ASPHALT PAVEMENT AND SUB- BASE MATERIAL DOWN TO NATIVE SOIL. " SUB -BASE MATERIAL NATIVE SOIL TOPSOIL FILL - REFER TO SPECIFICATIONS FOR SOIL TYPE PARKING ISLAND PLANTER DETAIL au Reek 5l des mpg-0461A NTS NTS w 1- SHRUBS /CsROUNpGOVERS PLANT MATERIAL_ L_ 1ST QTY. 1 BOTANICAL NAME KATSURA TREE 1 COMMON NAME 6 1 SIZE 4 SPACING 4 CERCIDIPHYLLUM JAPONICUM KATSURA TREE 16.'-20' HT., 5' MIN. BRANCH HT., 545, 3" CAL. 6 TILIA CORDATA 'GREENSPIRE' 'GREENSPIRE' LINDEN 16'-20' HT., 545, 3" CAL. N 4-, 0 5 CLEMATIS ARMANDII EVERGREEN CLEMATIS 5 GAL. CONT. - ATTACH VINES TO WIRE WITH PLANT TIES. 30 COTONEASTER DAMMERI BEARBERRY COTONEASTER 1 GAL. CONT. 6 2' O.C. 5 FOTHERGILLA MAJOR 'MT. AIRY' 'MT. AIRY' FOTHERGILLA 2 GAL. CONT. 6 21/2' O.C. 14 HEMEROCALL IS 'STELLA D'ORO' 'STELLA D'ORO' DAYL ILY . 1 GAL. CONT. a 21 2' O.C. 35 ILEX CRENATA 'SOFT TOUCH' 'SOFT TOUCH' HOLLY 1 GAL. CONT. 6 2' O.C. 54 JUNIPERUS SQUAT" IATA 'BLUE STAR' 'BLUE STAR' JUNIPER 2 GAL. CONT. 6 2' O.C. 6 NASSELLA TENUISSIMA MEXICAN FEATHER GRASS 1 GAL. CONT. 6 3' O.C. 5 RHAPHIOLEPIS UMBELLATA 'B4Y BREEZE' 'BAY BREEZE' RHAPHIOLEPIS 5 GAL. CONT. 6 3' O.C. 10 SARCOCOCCA HOOKERANA HUMUS DWARF HIMALAYAN SWEETBOX 1 GAL. CONT. 6 12" O.C. 35 SPIREA JAPONICA 'MAGIC CARPET' 'MAGIC CARPET' SPIREA 2 GAL. CONT. 6 212' O.C. IRRIGATION EQUIPMENT L_ (ST SYMBOL 1 MFR. 1 CATALOG NO. I DESCRIPTION AREA FOR SPACING ADJUSTMENT f12�� TRIANGULAR SPACING WITHIN PLANTING BED IRRIGATION SPECIFICATIONS 1. This plan is diagrammatic; all piping, valves, etc. shall be installed in shrub beds where possible and shall follow the plan as close as is practical. 2. Locate all mainlines within the project limits. 3. Pipe sizes are constant between pipe size call -outs. 4. Refer to details for additional information. 5. All piping and wiring under paved areas shall be housed in class 200 PVC sleeves installed at a 24" depth. Size sleeves as needed to accommodate pipe and wires, unless otherwise specified on drawing. 6. Contractor shall make field adjustments as needed to obtain full coverage. Landscape Architect reserves the right to make nozzle changes as needed at no additional cost. Adjust head positions and add or delete heads as needed depending on actual field conditions. 7. All manual, gate and electrical valves and other underground equipment shall be housed in Nelson, Ametek or equal rectangular valve boxes. 8. No in -line wire splices allowed. Supply valve boxes at all electrical junctions. Tape and bundle wires every 25 linear feet. 9. Contractor is responsible for complete system drainage. Install King Bros. 1/2" automatic drain valves at lateral line low point(s). Install manual drains at all mainline low point(s) and where indicated on plan. Contractor shall provide adjustable check valves on any irrigation head that experiences low head drainage. 10. All threaded pipe connections shall be made using Teflon tape wrapped at least three times around pipe threads. 11. All gate and electric valves shall be installed with unions on the downstream end of the valve (refer to details). 12. All pipe shall have a firm uniform bearing for the entire length of each line, free of rocks or debris. All trenches containing pipe and /or wires shall be backfilled with clean topsoil, free of all lumber, rubbish and rocks over 1" in size, or clean sand if clean topsoil is not available. 13. Secure Techline dripperline with 6" soil staples (TLS6) appoximately every 3' plus two at each tee, elbow or cross. 14. Contractor shall provide owner with one set of as -built record drawings showing exact actual locations of all sprinkler equipment. Contractor shall orient owner with complete system and controller operations, and winterization procedures. 15. Contractor shall supply and install all equipment shown on the plans and indicated in the specifications to achieve proper operation of said equipment. All equipment installations, electrical and plumbing connections shall be in conformance with all applicable codes and ordinances, these specifications, and the manufacturers recommendations whether indicated on the drawings or not. 16. Contractor shall include in his bid one Fall winterization and one Spring activation of irrigation system. These activities shall be included as part of Owner orientation procedures. Any damage to the irrigation system or the landscape as a result of failure to comply with these requirements shall be the sole responsibility of the Contractor. 17. Contractor shall guarantee in writing on his company letterhead all materials and workmanship for a period of one full year following acceptance of system installation. REVI510N N0;1 tj I O' L 1 1 CONTINUOUS OUTER ROW OF PLANTS SPACED "X" ON CENTER AND SET BACK FROM THE PLANTING BED EDGE 2/3 "X" 2/3 "X" EDGE OF PLANTING BED • SPECIFIED PLANT SPACING = "X" INDIVIDUAL PLANTS REPRESENTED AS: + OPA_VVOiadMittrIviv PLANT SPACING TAIL NTS PLANTING PIT SHALL BE A MIN. OF TWICE THE ROOTBALL DEPTH PLANTING PI SHALL BE A MINIMUM OF TWICE THE ROOT - BALL WIDTH SHRUB PLANTING DETAIL MULCH WATERING B TREE REMOVAL 4 REPLANT IN& Per 18.54.130 - Permit Approval Criteria 3. Tree replacement - the site shall be planted with trees to meet the following minimum requirements: a. Each existing significant tree removed shall be replaced with new tree(s), based on the size of the existing tree as shown below, up to a maximum density of 70 new trees per acre. Tree replacement ratios diameter of existing no. of replacement tree removed trees required 8 - 12 inches 2 1" CHAINLOCK TREE TIES REVIEWED FOR CODE COMPLIANC PP ninED SIN BM_ ]. 810 FERTILIZER TABLETS 2 " -6" DEP PEEL BUR FROM TOP ROOT BALL PLACING SHRUB IN PLANTING HOLE (REMOVE COMPLETELY IF FIBERGLASS OR TREATED). BACKFILL SOIL MIX ity of Tukwila DING nIVi inni (CONT., B & B) NTS b. Prior to any vegetation removal, the applicant shall demonstrate through a landscape plan, sensitive area mitigation plan or other materials required per the requirements of this chapter that vegetation replacement will meet the following minimum standards: (1) Minimum sizes shall be 2.5 -inch caliper for deciduous trees, 6 to 8 feet in height for evergreen trees, 24 inches in height for shrubs, and lgallon for groundcover. 43" (2) Replacement plants shall meet current American Association of Nurserymen Standards for nursery stock; (3) Planting and maintenance of required replacement vegetation shall be in accordance with best management practices for landscaping which ensure the vegetation's long -term health and survival. ' •.. 4:4 .. "'J rte 1 ROOT - BALL DEPTH 24" MIN. -R =n =II= 1= 11 =11 =11 PLANTING PIT - SHALL BE A MINIMUM OF TWICE THE ROOTBALL WIDTH. (2)- BVC WOOD TREE STAKES (8' HT.) 2" MULCH IN BASIN OP ATER RETENTION GROUNDCOVER AREAS ONLY) IN (IN SHRUB AND FERTILIZER TABLETS REMOVE BURLAP FROM TOP 2/3 OF ROOT BALL. BACKFILL SOIL MIX NOTES: 1. REMOVE TREATED OR SYNTHETIC BURLAP COMPLETELY. 2. INSTALL 24" DEPTH ROOT BARRIER AT THE EDGE OF ANY PAVING WITHIN, 8• FT. OF TREE TRUNK. 1.,,c9. GGtv10 {.3 eT(�.�.- (� TREE PLANTING AND STAKING DETAIL RECEIVED CITY OF TUKWIIA JUN S02010 PERMIT CENTER NTS ST' 7. OF WAS TON REGI uRED LANDSCA" :/ARCHITECT Via■• effre tifica Glander e No. 405 ° °° °° °° °° °° °°° o °o °o °o °o °o °o° NETAFIM TECHLINE CV TLCV -6 -12 CONTINUOUS SELF CLEANING DRIPPERLINE WITH CHECK VALVE WITH 12" IN -LINE DRIPPER SPACING 4 0.6 GPH DRIPPER FLOW. SPACE DRIPPERLINE ROWS 1S" APART. N 4-, 0 0 B 4 K 10-1 -900 SERIES BRASS BALL VALVE W/ BRASS UNIONS (MATCH LINE SIZE) O RAINBIRD 3RC 3/4" BRASS QUICK COUPLER VALVE NOT SHOWN NETAFIM TLSOV MANUAL DRAIN VALVE FOR DRIPPERLINE - INSTALL PER DETAIL THIS SHEET * NETAFIM 10 -F -01 OPERATION /PRESSURE INDICATOR STAKE (INSTALL IN INDIVIDUAL VALVE BOX PER DETAIL) NOT SHOWN TORO T- ALFD-15150 -L 3/4" PLASTIC "Y" DRIPPER LINE FILTER - INSTALL PER DETAIL THIS SHEET OI TORO P220- 21-04 1" ELECTRIC REMOTE CONTROL VALVE W/ FLOW CONTROL AND EZ -REG PRESSURE REGULATING VALVE - SET OUTPUT TO 30 PSI c TORO TMC- 212 -OD 4 STATION MODULAR CONTROLLER IN LOCKABLE CABINET PRESSURE MAINLINE, SCH. 40 PVC PIPE, INSTALL ' 18" DEPTH (24" UNDER PAVED AREAS) S LATERAL LINES, CLASS 200 PVC PIPE, INSTALL 6 12" DEPTH (24" UNDER PAVED AREAS) S LATERAL LINE SUPPLY HEADER (SIZE PER PLAN), CLASS 200 PVC PIPE, INSTALL 6 12" DEPTH (INSTALL PER LATERAL TO CENTER - /END -FEED DRIPLINE CONNECTIONS DETAIL) NOT SHOWN 3/4" EXHAUST HEADER, CLASS 200 PVC PIPE, INSTALL e 12" DEPTH (INSTALL PER LATERAL TO CENTER - /END -FEED DRIPLINE CONNECTIONS DETAIL) 8L. - CLASS 200 PVC PIPE SLEEVES, INSTALL e 24" DEPTH NOT SHOWN 14 -AWG DIRECT BURIAL LOW VOLTAGE WIRE, RED = SIGNAL WHITE= COMMON AREA FOR SPACING ADJUSTMENT f12�� TRIANGULAR SPACING WITHIN PLANTING BED IRRIGATION SPECIFICATIONS 1. This plan is diagrammatic; all piping, valves, etc. shall be installed in shrub beds where possible and shall follow the plan as close as is practical. 2. Locate all mainlines within the project limits. 3. Pipe sizes are constant between pipe size call -outs. 4. Refer to details for additional information. 5. All piping and wiring under paved areas shall be housed in class 200 PVC sleeves installed at a 24" depth. Size sleeves as needed to accommodate pipe and wires, unless otherwise specified on drawing. 6. Contractor shall make field adjustments as needed to obtain full coverage. Landscape Architect reserves the right to make nozzle changes as needed at no additional cost. Adjust head positions and add or delete heads as needed depending on actual field conditions. 7. All manual, gate and electrical valves and other underground equipment shall be housed in Nelson, Ametek or equal rectangular valve boxes. 8. No in -line wire splices allowed. Supply valve boxes at all electrical junctions. Tape and bundle wires every 25 linear feet. 9. Contractor is responsible for complete system drainage. Install King Bros. 1/2" automatic drain valves at lateral line low point(s). Install manual drains at all mainline low point(s) and where indicated on plan. Contractor shall provide adjustable check valves on any irrigation head that experiences low head drainage. 10. All threaded pipe connections shall be made using Teflon tape wrapped at least three times around pipe threads. 11. All gate and electric valves shall be installed with unions on the downstream end of the valve (refer to details). 12. All pipe shall have a firm uniform bearing for the entire length of each line, free of rocks or debris. All trenches containing pipe and /or wires shall be backfilled with clean topsoil, free of all lumber, rubbish and rocks over 1" in size, or clean sand if clean topsoil is not available. 13. Secure Techline dripperline with 6" soil staples (TLS6) appoximately every 3' plus two at each tee, elbow or cross. 14. Contractor shall provide owner with one set of as -built record drawings showing exact actual locations of all sprinkler equipment. Contractor shall orient owner with complete system and controller operations, and winterization procedures. 15. Contractor shall supply and install all equipment shown on the plans and indicated in the specifications to achieve proper operation of said equipment. All equipment installations, electrical and plumbing connections shall be in conformance with all applicable codes and ordinances, these specifications, and the manufacturers recommendations whether indicated on the drawings or not. 16. Contractor shall include in his bid one Fall winterization and one Spring activation of irrigation system. These activities shall be included as part of Owner orientation procedures. Any damage to the irrigation system or the landscape as a result of failure to comply with these requirements shall be the sole responsibility of the Contractor. 17. Contractor shall guarantee in writing on his company letterhead all materials and workmanship for a period of one full year following acceptance of system installation. REVI510N N0;1 tj I O' L 1 1 CONTINUOUS OUTER ROW OF PLANTS SPACED "X" ON CENTER AND SET BACK FROM THE PLANTING BED EDGE 2/3 "X" 2/3 "X" EDGE OF PLANTING BED • SPECIFIED PLANT SPACING = "X" INDIVIDUAL PLANTS REPRESENTED AS: + OPA_VVOiadMittrIviv PLANT SPACING TAIL NTS PLANTING PIT SHALL BE A MIN. OF TWICE THE ROOTBALL DEPTH PLANTING PI SHALL BE A MINIMUM OF TWICE THE ROOT - BALL WIDTH SHRUB PLANTING DETAIL MULCH WATERING B TREE REMOVAL 4 REPLANT IN& Per 18.54.130 - Permit Approval Criteria 3. Tree replacement - the site shall be planted with trees to meet the following minimum requirements: a. Each existing significant tree removed shall be replaced with new tree(s), based on the size of the existing tree as shown below, up to a maximum density of 70 new trees per acre. Tree replacement ratios diameter of existing no. of replacement tree removed trees required 8 - 12 inches 2 1" CHAINLOCK TREE TIES REVIEWED FOR CODE COMPLIANC PP ninED SIN BM_ ]. 810 FERTILIZER TABLETS 2 " -6" DEP PEEL BUR FROM TOP ROOT BALL PLACING SHRUB IN PLANTING HOLE (REMOVE COMPLETELY IF FIBERGLASS OR TREATED). BACKFILL SOIL MIX ity of Tukwila DING nIVi inni (CONT., B & B) NTS b. Prior to any vegetation removal, the applicant shall demonstrate through a landscape plan, sensitive area mitigation plan or other materials required per the requirements of this chapter that vegetation replacement will meet the following minimum standards: (1) Minimum sizes shall be 2.5 -inch caliper for deciduous trees, 6 to 8 feet in height for evergreen trees, 24 inches in height for shrubs, and lgallon for groundcover. 43" (2) Replacement plants shall meet current American Association of Nurserymen Standards for nursery stock; (3) Planting and maintenance of required replacement vegetation shall be in accordance with best management practices for landscaping which ensure the vegetation's long -term health and survival. ' •.. 4:4 .. "'J rte 1 ROOT - BALL DEPTH 24" MIN. -R =n =II= 1= 11 =11 =11 PLANTING PIT - SHALL BE A MINIMUM OF TWICE THE ROOTBALL WIDTH. (2)- BVC WOOD TREE STAKES (8' HT.) 2" MULCH IN BASIN OP ATER RETENTION GROUNDCOVER AREAS ONLY) IN (IN SHRUB AND FERTILIZER TABLETS REMOVE BURLAP FROM TOP 2/3 OF ROOT BALL. BACKFILL SOIL MIX NOTES: 1. REMOVE TREATED OR SYNTHETIC BURLAP COMPLETELY. 2. INSTALL 24" DEPTH ROOT BARRIER AT THE EDGE OF ANY PAVING WITHIN, 8• FT. OF TREE TRUNK. 1.,,c9. GGtv10 {.3 eT(�.�.- (� TREE PLANTING AND STAKING DETAIL RECEIVED CITY OF TUKWIIA JUN S02010 PERMIT CENTER NTS ST' 7. OF WAS TON REGI uRED LANDSCA" :/ARCHITECT Via■• effre tifica Glander e No. 405 N 4-, 0 C 0 •N '5 a) L O C 10 -0601 job no. RK drawn TLG /JBG checked 06/28/10 date W 0 0 soul IIW 0\ Landscape Architecture Site Planning 1821 4th Avenue E. Olympia, WA 98506 ph. (360) 357 -6972 1x. (360) 786 -8073 www.glanderassociates.com FT sheet L -3 of 3 WESTFIELD MALL AT SOUTHCENTER TENANT IMPROVEMENT GAS METER ALCOVE MODIFICATIONS Code Summary CODE SUMMARY: IBC 2006 - INCLUDING WASHINGTON STATE AMENDMENTS FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. CIVIL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. PERMIT TYPE - TENANT IMPROVEMENT AT EXISTING COVERED MALL BUILDING SITE INFOEIMATION: ADDRESS: 2800 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -0010 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL SQUARE FEET: 198 SF EXTERIOR GAS ALCOVE OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL CONSTRUCTION TYPE: IIB OCCUPANCY LOAD: NOT APPLICABLE - NO ADDITIONAL BUILDING SQUARE FOOT ADDED TO BUILDING. EXTERIOR ALCOVE EGRESS REQUIREMENTS: NOT APPLICABLE - HOWEVER GATE IS PROVIDED TO ALCOVE AND IS 41 -011 IN WIDTH THEREFORE MEETING MINIMUM CLEARANCE WIDTH REQUIRED OF 32". MINIMUM 3' -0" CLEARANCE 51-1ALL BE PROVIDED AROUND EQUIPMENT IN ACCORDANCE TO PUGET SOUND ENERGY REQUIREMENTS. ALL CONSTRUCTION MATERIALS SHALL BE CONSTRUCTED OF NON - COMBUSTIBLE MATTERIALS. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees, Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT: FIRE ALARM, FIRE SPRINKLER, SIGNAGE, MECHANICAL, ELECTRICAL, CIVIL, LANDSCAPE, AND PLUMING SHALL BE UNDER SEPARATE PERMIT TO BE SUBMITTED BY CONTRACTOR General Notes I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK. ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE- CONTRACTOR AND PO NOT SHOW EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO FLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER 10. ALL INTERIOR GOB IS B" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GWB. 11. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 12. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 13. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 14. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 15• INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 16. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. PLANNING APPROVED . No changes can be made. to these plans without approval from the Planning Division of DCD Approved By:, k 1,{AIRO 6CAI! Date: Scope of Work SCOPE OF WORK SHALL INCLUDED THE CONSTRUCTION OF A 198 SF GAS METER ALCOVE ON THE EAST ELEVATION OF THE EXISTING MALL FOR FUTURE MALL AND TENANT GAS METERS. THE SCOPE OF WORK SHALL INCLUDE THE CONSTRUCTION OF A CONCRETE SLAB ON GRADE, CONCRETE FOUNDATION AND A 8' -0" MASONRY WALL AROUND THE LOCATION OF FUTURE GAS METERS. GAS METERS ARE TO BE INSTALLED BY PUGET SOUND ENERGY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING DESIGN BUILD PROFESSIONALS FOR ALL ASSOCIATED MECHANICAL, ELECTRICAL, CIVIL, FIRE SPRINKLER LANDSCAPE, AND FIRE ALARM FOR THIS TENANT IMPROVEMENT. Drawing Index ARCHITECTURAL T1.0 TITLE - COVER SHEET A1.0 FLOOR PLAN, REFLECTED CEILING PLAN A1.1 PARTIAL ROOF PLAN, SECTION, AND DETAILS A2.0 ELEVATIONS AND DETAILS S1.0 GENERAL NOTES S1.1 SPECIAL INSPECTION 82.0 PLANS AND DETAILS Vicinity Map _.._,,5,154th St r.53rd Ave S • ti IL_5 152nd Pig , .1 11 �- `t'is is4th st T S 153rd 5t� 1 'tirukwlfa Pa 1 Qtl 5151st kk `° )j 164th fit Crystal Springs; Park r St S 159th St rk • Slade way WESTFIELD_ MANAGEMENT OEEI.CESATE SOUTHCENTER 167t St , ... 5:166th Ln' _- M._. I a rtkw)ia Ponid . Evans_ Black t Baker Blvd ti Strander Blvd . Treck Dr FILE COPY Permit No. 10 J►11 , Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and co • 'on ' - acknowledged: By, Date: co, •2D. 4 0 City Of Tukwila BUILDING DIVISION Project Directory UJEA SOUTHCENTER, LLC 2800 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER: ANDREW CIARROCHI T - 206246.0423 F - 206244.8601 MALL OPERATIONS: PAT BUMS T - 206246.0423 F - 206244.8601 C - 206.186,9011 PBURNSGWESTFIELD.COM ARCHITECT S.M. STEMPER ARCHITECTS, PLL.C. 4000 DELRIDGE WAY SW, SUITE 200 SEATTLE, WA 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER T - 206.624 -2111 F - 206.624 -2913 waynetlemstemper.com STRUCTURAL ENGINEER PSM ENGINEERS, INC. 2200 SIXTH AVENUE, SUITE 601 SEATTLE, WA 98121 CONTACT: MUNI VIMAWALA T - 206.622.4580 F - 206.622.0422 MUN I V.PSM- ENGINEERS.COM • REVIEWED FOR CODE APPRIIIVED COMPLIANCE JUN 17 2010 Ci BUILDING kwila Ivicint r t' Site Plan ALCOVE LOCATION mervyns 2 LEVELS CIA TUKNALA MAY 0 5 2010 PERMIT CENTER pio-1v1 • WeslIle[c[ South center a33 southant.r Parkway 'Marla, WA., 9elee -2ee9 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS ME PROPERTY OF ME ARCHITECT AND MAY NOT BE REPRODUCED YAMOUT ME ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DE9CN AND OTHER INFORMATION SHOWN ON THE DRAWNG ARE FOR VSE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERYASE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (200) 624 -2973 z 0 I- 0 U_ LL 0 w 0 U w Cw 0 ISSUE ISSUE PERMIT SET DATE: MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA #1022.02 ft / / / / /l / / /0/I /l /! // `0, / / / / / / /lUl / /, / /// f/miiU // / / / / / / / / / / / //y LIGHT BOLLARDS (3) OWNER RIRNISHED CONTRACTOR INSTALLED DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTING LIGHT BOLLARDS (3) OWNER RIRNISHED CONTRACTOR INSTALLED DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTING LIGI4T BOLLARDS (2) OWNER FURNISHED CONTRACTOR INSTALLED 1, 4,11 jE Sri Pit to it l�> I (E) UTILI 1 VAULT - eTRileE AROUND VAULT d) X REVISED PARKING > STALL STRIPING AS REQUIRED - TYPICAL 11 N LANDSCAPE X ISLAND - TYPICAL w RE: LANDSCAPE PLANS 7 X w x w a EXISTING PARKING TO REMAN <4 I TO DEMO TREE AND GRATE (2) INFILL WITH CONCRETE TO MATCH EXISTING LIGI4T BOLLARDS (2) OWNER FURNISHED CONTRACTOR INSTALLED GAS ALCOVE - REMAN TTPICN. SEE LARGER PLANS O K I X EXISTING PARKING \ , ;, TO REMAIN \ \ \ \ \ \\\ BIKE RACK TO BE REMOVED AND NEW RACK INSTALLED SOUTH OF WESTFIELD ENTRANCE DEMO TREE AND GRATE INFILL WITH CONCRETE TO MATCH EXISTING BIKE RACK TO MATCH RACKS AT SOUTH SIDE OF MALL (E) LANDSCAPE X = ISLAND - TO BE w RE- PLANTED RE: LANDSCAPE tr PL 5 //7 N \N\ N w I 4> < 1 ;Awl 15" PLUl;a 16" PLUM- 2" OAK 1 n" OAK 4" OAK 4" OAK 10" OAK 8" PLUM 8" PLUM 12" OAK N :/I 11" PLUM PLUM 5" DE' /1:1 0" OAK CI 10) 12" OAK 12" PLUM_. 15" PLUM -- 6" PLUM- 14" PLUM _ OAK GRASS GRASS v v v v v REVISED PARKING STALL STRIPING TO ACCOMMODATE NEW LANDSCAPE ISLANDS u EXISTING PARKING STALL STRIPING TO REMAIN .3/4" LANDSCAPE ISLAND WITH TREE AND VEGETATION RE: LANDSCAPE I0' -II Inn 6" CONCRETE CURB ISLAND RE: CIVIL TYPICAL LANDSCAPE ISLAND 1/4" = 1' -0" GENERAL NOTES: L LANDSCAPE AND CIVIL PLANS SHALL BE SUBMITTED SEPARATELY SHOWING THE DETAILS OF THE LANDSCAPE ISLAND, DRIVES, MD PLANTING DETAILS. 2. CONTRACTOR SHALL REMOVE EXISTING STRIPING AND REVISE THE STRIPING AS SHOWN TO ACCOMMODATE THE REQUIRED PARKING STALLS ADJACENT TO EACH LANDSCAPE ISLAND. 3. CONTRACTOR SHALL REMOVE TREES AND GRATES DESIGNATED TO BE REMOVED AND INSTALL MNIMUM 4" CONCRETE SLAB ON GRADE SIDEWALK INFILL WITH REQUIRED REINFORCING PER CIVIL PLANS. CONCRETE SHALL MATCH EXISTING CONCRETE SIDEWALK IN FINISH, TEXTURE AND COLOR AS BEST AS POSSIBLE. 4. LANDSCAPE ISLANDS SHALL NOT IMPEDE ON REQUIRED DRIVE WIDTH, PARTICULARLY FIRE LANE NDICATED ALONG EAST SIDE OF BUILDING. REVIEWED FOR CODECOMPLIANCE JUN 1 7 2010 City of Tukwila BUILDING ona.inhi 16" PLUM- 1 3 "PLUM ARCHITECTURAL SITE PLAN 1" = 30' -0" f � n RECEIV D CITY OF TUKWII.A JUN 1 Lt 2010 PERMIT CENTER CORRECTION LTR# Pi 0 111 Westilek! South center 633 Soutoenter Parkway Tukwila, WA, 9e188 -2888 260 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, Califomia 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 TMs DRANINO IS AN NSIRUUFNT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT MA MAY NOT BE REPRODUCED YATNWT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. AU. DESIGN AND OTHER INFORMATION SHOYM ON THE °RAYING ARE FOR USE ON THE SPECIFIED PROJECT CNLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 co oo OO Z 0) U < Q 0 c N ISSUE A6 -11 -10 ISSUE DATE: PERMIT SET MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ SITE PLAN A0.0 SMSA #1022.02 (E) DOOR TO REMAIN (E) TENANT DROP BOX TO REMAIN (E) EXTERIOR WALL ASSEMBLY TO REMAIN OUTLINE OF SOFFIT ABOVE (E) DOOR HEAD TO REMAIN \ __L.__ ''CI l �� / \ (E) TREE AND SIDEWALK GRATE TO BE DEMOLISHED. INFILL WITH CONCRETE SIDEWALK CONCRETE SHALL MATCH (E) SIDEWALK N COLOR AND TEXTURE ♦ -- / ♦ \ / / \ / ' / / / 1 / / / / CONCRETE SLAB ON RE: STRUC �I () (3-t ( (E) DRIVE (E) CONCRETE CURB TO REMAIN (E) SIGN TO REMAIN (E) EXTERIOR WALL ASSEMBLY TO REMAIN 12 X 4 X 46 TUBE STEEL RISER CHASE FOR FUTURE GAS LINES (TYP. OF 4) t R LANDSCAPE AREA - WITH PRE -CAST STEM WALL AND CABLE TRELLIS (SEE SECTION A1.1) PLANTS TO BE DETERMINE BY OWNER pl C OUTLINE OF (E) SOFFIT (E) RECESSED LIGI4T FIXTURE TO BE CHANGED OUT TO NIGH IMPACT BLAST RESISTENT FIXTURE RE: ELECTRICAL ri I I I I 11 1 1 rt-I 11 I I J TENANT GAS METERS AND MANIFOLD RE: PUGET SOUND ENERGY TENANT GAS METERS AND MANIFOLD RE: PUGET SOUND ENERGY (E) BIKE RACK TO BE DEMOLISHED IN ITS ENTIRETY EXISTING GAS RISER TO REMAIN —1' I r`1 4' -0" -IC - -_L. ' \ / IC/ - 1. 1 k OUTLINE OF SOFFIT ABOVE NORTH 1/2" = 1' -0" (E) TREE AND SIDEWALK GRATE TO BE DEMOLISHED. INFILL WITH CONCRETE SIDEWALK CONCRETE SHALL MATCH (E) SIDEWALK IN COLOR AND TEXTURE (E) EXTERIOR WALL ASSEMBLY TO REMAIN (E) GAS RISER TO REMAIN (E) RECESSED L _ _ J LIGHT FIXTURE TO BE CHANGED OUT TO HIGH IMPACT BLAST RESISTENT FIXTURE RE: ELECTRICAL OUTLINE OF EXIST. SOFFIT REFLECTED CEILING PLAN 1 /2" = 1' -0" MASONRY WALL BELOW (E) SOFFIT TO BE DEMOLISHED FOR INSTALLATION OF TUBE STEEL CHASE AND PATCHED TO ORIGINAL CONDITION. PATCH SHALL MATCH N COLOR, TEXTURE, AND FINISH. NOTE: WALL TYPE 1 (NON- RATED) CONCRETE MASONRY UNIT VERTICAL AND HORIZONTAL REBAR RE: STRUCTURAL MASONRY CLIPS AT MINIMUM 16" OL. HORIZONTALLY AND 24" O.C. VERTICALLY. FULLY ADHERED BUILDING PAPER / LIQUID APPLIED MOISTURE BARRIER APPLIED TO CMU VERTICAL REBAR - RE: STRUCTURAL 319 X 8" BRICK VENEER TO MATCH EXISTING BRICK ANTI - GRAFFITI / WATER REPELLENT COATING SHALL BE APPLIED TO EACH SURFACE OF MASONRY. WALL TYPE 1" = 1 8' MASONRY STEM WALL BASE TO MATCH EXISTING BASE (E) RECESSED LIGI4T FIXTURE TO BE CHANGED OUT TO HIGH IMPACT BLAST RESISTENT FIXTURE RE: ELECTRICAL \/ tSMFORCED CONCRETE FOUNDATION RE: STRUCTURAL REVIEWED FOR ODE COMPLIANCE APPROVE' JUN 17 2010 BRICK VENEER TO MATCH EXISTMCs WITH MASONRY TIES FULLY ADHERED BUILDING PAPER/ LIQUID APPLIED MEMBRANE TYPICAL - OVERLAP FLASHING - GALV. THRU WALL FLASHING WITH DEEP HOLES 24' OL. TYPICAL. TOPSOIL / PLANTING BED AND LANDSCAPING BY OWNER IsINFORCED CONCRETE FOUNDATION RE: STRUCTURAL DETAIL 1 1/2" = 1' -0" RECEIVED CITY OF TUK\MLA JUN 1 it 2010 PERMIT CENTER Illestflefif Southcenter 833 Sou heent.r Powkwr Voila. WA.. 96188 -7286 206 -248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERWCE, IS THE PROPERTY OF NNE ARCHITECT AND MAY NOT BE REPRODUCED NTTHOUT 1HE ARCHITECTS PERLISSCN AND UNLESS THE REPRODUCTION CARRIES RE ARCHITECTS NAME ALL DESIGN AND OTHER HFORMA110N SHORN ON THE DRANK ARE FOR USE ON 111E SPECIFED PROECT ONLY AND S"ALt NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 ISSUE ISSUE DATE: 0 OC w 0 U Q J cc w w 2 0 co W co I- Z 0) w U < DQ O --I o � co N H 6/11/10 A5/24/10 PERMIT SET MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN AND RELFECTED CEILING PLAN A1.0 SMSA #1022.02 (E) EPDM ROOF MEMBRANE AND BALLAST TO REMAIN FUTURE TENANT GAS PIPES AT EACH TUBE STEEL CHASE I' -6" /) /A /A /,1 J %;1 O LJ; 4 /1 /1 1 /) /,I 1' 2" (E) GAS PIPING TO REMAIN / I — •(" - -� \ (E) EPDM ROOF MEMBRANE AND BALLAST TO REMAIN ROOF MEMBRANE ASSEMBLY TO BE DEMOLISHED TO ALLOW FOR INSTALLATION OF TUBE STEEL AND SUPPORT FRAMING. PATCH TO WATERTIGHT CONDITION FF GALV. SHEET METAL SKIRT FLASHING RE: DETAIL 2 /AI.I (TYPICAL - 4 LOCATIONS) MIN.12 X 4 X 4 TUBE STEEL CHASE FROM ROOF TO SOFFIT (TYPICAL - 4 LOCATIONS) FUTURE TENANT GAS PIPES AT EACH TUBE STEEL CHASE ROOF PLAN 1 /2" = 1' -0" (E) ROOF PARAPET TO REMAIN (E) GAS PIPING TO REMAIN / RELOCATED TREE GRATE AND NEW TREE TO BE FURNISHED AND INSTALLED MASONRY WALL BELOW RELOCATED TREE GRATE AND NEW TREE TO BE FURNISHED AND INSTALLED \ / N. ■ \ / \ \ / `\ \ / \ i \ 1 \ i' \ ), \ / \ / ..' 1 FUTURE GAS PIPING BY FUTURE TENANTS FUTURE TENANT GAS PIPE 6 I SEALANT AT TOP OF EPDM MEMBRANE (E) EPDM MEMBRANE ASSEMBLY COVER BOARD TO MATCH (E) RIGID NSULATION d3f&b9ne4 MN. 12 X 4 X 9 TUBE STEEL CHASE (TYPL OF 4) FLEXIBLE SEALANT AT TOP CF RAN SKIRT / STORM COLLAR FF GALV. SHEET METAL RAN SKIRT/ STORM COLLAR SECURED TO TUBE STEEL WITH PPE CLAMP FULLY ADHERED EPDM MEMBRANE FLASHING CONTINUED UP TUBE STEEL (E) ROCK BALLAST (E) RIGID NSULATICN c9 o ft / DETAIL 1 1/2" 1' -0" (E) ROOF MEMBRANE WITH BALLAST OVER RIGID INSUL. TOP OF (E) STEEL 19' -0" (FIELD VERIFY) (E) METAL ROOF DECK TO REMAIN rUTURE TENANT GAS PIPE UP TO ROOF MIN. 12 X 4 X 3(6 TUBE STEEL CHASE (TYP. OF 4) (E) WALL ASSEMBLY \ STEEL ANGLE - EACH SIDE OF TUBE STEEL RE: STRUCTURAL DEMO (E) METAL ROOF DECK AS REQUIRED TO INSTALL TUBE STEEL CHASE (E) WALL ASSEMBLY TO REMAIN (E) PAR'4PAT TO REMAIN DEMO (E) ROOF INSULATION, METAL DECK AND MEMBRANE ASSEMBLY AS REQUIIRED TO INSTALL STEEL TUBE AND SUPPORT STRUCTURE RE: STRUCTURAL STEEL ANGLE SUPPORT RE: STRUCTURAL (E) WALL FRAMING AND BRICK VENEER TO REMAIN (E) WALL FRAMING TO REMAIN STEEL ANGLE SUPPORT RE: STRUCTURAL BOTTOM OF (E) SOFFIT I0' -0" 1/2" WIDE FLEXIBLE JOINT SEALANT AT EXISTING WALL AND NEW WALL TRANSITION TYPICAL MIN. CONTINUOUS 12 X 4 X 3/16 TUBE STEEL CHASE / DEMO EXIST. SOFFIT ASSEMBLY \\ AND PATCH AS r' REQUIRED TO INSTALL 1 TUBE STEEL CHASE / (E) SOFFIT AND FRAMING STEEL ANGLE - EACH SIDE OF TUBE STEEL RE: STRUCTURAL METAL STUD FRAMING RE: STRUCTURAL (E) METAL STUD SOFFIT FRAMING CONTRACTOR SHALL DEMOLISH AS REQUIRED TO INSTALL TUBE STEEL AND SUPPORTS NG BEAD AND FLEXIBLE SEALANT TYPICAL ALL AROUND AT EACH PENETRATION )1" EXTERIOR GM WITH STUCCO FINISH TOP COAT TO MATCH (E) SOFFIT 1/2" JOINT WITH FLEXIBLE SEALNT AT SOFFIT / WALL TRANSITION (E) ERICK VENEER DETAIL 1 1/2" = 1' -0" � 1 L BRICK MASONRY C FUTURE TENANT GAS PIPING DOWN TO METERS NOTES: I. CONTRACTOR SHALL BRACE AND SHORE EXISTING: WALL ASSEMBLIES, ROOF DECK AS REQUIRED FOR NSTALLATION aF TUBE STEEL CHASE. 2. CONTRACTOR SHALL DEMOLISH EXISTING SOFFIT FINISH AND FRAMING AS REQUIRED TO INSTALL TUBE STEEL CHASE FOR FUTURE GAS PIPING. AT COMPLETION OF TUBE STEEL CHASE INSTALLATION, CONTRACTOR SHALL PATCH SOFFIT TO MATCH EXISTING SOFFIT IN TEXTURE, COLOR AND FINISH AND SEAL WEATHERTIG 4T ALL AROUND TUBE STEEL CHASE. 3. CONTRACTOR SHALL DEMOLISH EXISTING ROOF DECK AND ROOF ASSEMBLY, INCLUDING BUT NOT LIMITED TO METAL DECK, VAPOR BARRIER, COVER BOARD, INSULATION, ROOF MEMBRANE, PROTECTION BOARD AND !BALLAST FOR INSTALLATION OF TUBE STEEL CHASE. At COMPLETION OF INSTALLATION OF TUBE STEEL CHASE CONTRACTOR SHALL INSTALL AND PATCH ROOF MEMBRANE ASSEMBLY TO MATCH EXISTING ASSEMBLY IN ACCORDANCE TO MANUFACTURER'S REQUIIR!ENT TO MAINTAN ANY CURRENT ROOF WARRANTY. 4. ROOF PENETRATIONS SHALL NCLUDE RAN SKIRT AND MEMBRANE FLASHING TO PROVIDE A SECURE AND U EATHTIGHT ASSEMBLY AT EACH PENETRATION. 5. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, INCLUDING IBUT NOT LIMITED TO FOUNDATION, ROOF ASSEMBLY, AND SOFFIT CONSTRUCTION. EXISTING TENANT DEMISING WALLS AND FIRE RATED ASSEMBLIES SHALL BE MAINTAINED THE AND AFTER CONSTRUCTION. 42.0 %%I \ —J / \ \ I 1 1 REINFORCED CONCRETE 1 MASONRY WALL WITH \\ 1 BRICK VENEER \\ I I 1 I RE: WALL TYPE (E) TREE AND GRATE TO BE RELOCATED BEYOND (TYPICAL OF 2) 6' -0" NIGH SOMERSET CABLE SYSTEM FUTURE TENANT GAS METERS BY PSE UNISTRUT FRAME BY PSE FIRST LEVEL FF 01 -01I 071 IIS .II mitt 6 3/8' Li•lckt -ice i• -iii- -i�i��i��I•- I••rl•-1•i J7 DEMOLISH EXIST. LANDSCAPE AND REPLACE WITH NEW LANDSCAPING. TOPSOIL AS REQUIRED FOR NEW LANDSCAPING MATERIAL (E) SIDEWALK TO REMAIN (E) CURB AND DRIVE TO REMAIN \ 4 I a \\ \\ -I \\ \ \ \ \ \ \ / \ / \ \ / \/ \ �i \ /i,/ \\/// ` \ / /\ / / \ /` \ / / \�j \� / \ \ \�j \ / / \ //\ \�,\ III x 20 PRECAST CONCRETE .\\,\ A /X \ \ /\\ / \ \ / / \ /�� \/\ / , \� /� /�� /,., , \ /�\ CURB WITH SMOOTH FINISH MASONRY BASE TO MATCH / (E) BASE CONCRETE FOUNDATION AND STEM WALL RE: STRUCTURAL 3' -611 SECTION 1/2" = 1' -0" CONCRETE SLAB WITH GRA BASE AND VAPOR BARRIER ON GRADE RE: STRUCTURAL REVIEWED FOR CODE COMPLIANCE APPMVED JUN 17 2010 City o f Tukwila BUILDING riniicinhi RECEIVE[ MAY 25 2010 PERMIT CENTER Wsule[tf Southcenter 633 Scathanter Parkway Tukwila. WA., 98166 -2886 206- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND NAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME, ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAPING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SMALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ISSUE ISSUE DATE: PERMIT SET MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ PARTIAL ROOF PLAN SECTION AND DETAILS A1.1 SMSA #1022.02 L L _,___F- J_ �_ - -1 L_._1 1 T 1 �_L L�1 i T 1 1 11 , L1 �1 1 1 t_S _ _.1 T 1 _1 1 ---1- 1 ( r _1 l� 11 L 1 1 -1 I L l I I. _L I� I T L 1 T-L1 1 i 1 1 1 1 I I 1 1 T ( 1- T 1 ! __i__ L ! 1 I 1 �___I 1 1 1 F 1 - Z-- -j---1 J .i -1 r - 1_-1 1 1 1 -1 -` ' � -- -'--- 1 _ -_ -L _.1T - - -I- [T�- J--T__� I -rTC- �. -I -i 1` I J 1 I L 1 1 1~ 7 I T I I- -i T-- 1 1 1 1 T i 1 1 >- 1 >" ! 1 L 1 ___i_ I I 1 1 _, 1__. L__ ._l r _L I._ __.L__ `� - -- -_1 -_ ___1- -L _ TL_ __1 1_ 1 L 1__ ,_ 7111----1- �. _ T _ ._�_T I �._ 1 I I -_ 1 � [- �- 1� - I T ! �i i" I F._ __E T_ _ _F- __I._ _L I . _�__ 1 L. �__. I .1 r 1 i -1 - _ (- 1 - -1- -! 1 - --1-- -U --L- T- _ 1- 1 1 1-- ! 1._ ! J L J T 1 T 1 ! ,� -I 1_._ __I_ L l 1�__.i- I_ 1_ L 1 L -T- _ ! I l ! 1 _r 1- �f i T- T 1-- {- L 1 T 1 1 T-' - L.I- 1 �7 i 1 1- T --T 1 f ( Nei 1 1_ J _L 1 1 L_ _1 i L _1 I 1_ .I ___1_ J- I �/l 1 T I 1 I _.I I L 1- _I i 1 i 1 I _.__1 _.__I-_ _L_,�?.._ ___.I__ 1__. l_ . 1 _ 1 _.._L > -I. 1 _L__� L_I_ 1 -� J.c � 1 f 1_ L 1_._ 1_._ Z -T J I T 1 _T ! I I 1 1, I L._ -__L_ I.- _ -C _.1._ _._L_. ___1- _ _.._. 1__,__L. T J LT- I �I �1 ---T -- 1 T -J _1 _L L 1 1 1 -1 1- 1 i 1 qtr 1 T -1 1- _L_. _L _S _ L_ I L 1- _._1= _-1._ i _ I__ _ 1 _� 1 . -- •1-- •! . L •-∎ I: - L T l 1-- I_ - -T-- -I - - -L -f I 1 1 1 `/ 1 7 r�T I_ 1-11 l I LTT LL 11 [ _( t, [ 1 }�I 1 1 1 L 1 1 1 T -I 1 L L F- i- _.._I i t _1 1 1 1 -1 I I_, L L _L 1 T I T l 1 L 1 r- 1 ! 1 ' L L_.T-1 1 1 T L 1 F- F_ T J r 1 1 �l T L 1 �I 1 i H L__r __.1_t 1 L 1 L 7_1_7 1 1 LL1 7_1 1 1 L 1 1 J 1 1 1 1 it Li 1 1 1 1 1 T L 1 7 LJ �l 1 I-1 11 i� 1 1_ 1 t 1 ! L 1 1 1 1 1 1 L i -E.- 1 Z 1 1 1_ 1 1 I 1 1_1 I 1-_-_ 1= [ -1 T_-_.j -T. I ! I_ 1 r _ 1 1 1 _LL 1- - -1-I _L_ I � 1�� 1 -i i 1 1- 1 i l I 1� 1 1 I �` L 111_ 1 1 I LJ L I �� L L T q T- t\ 1 i 1 T___1 L 11 7- J 1 T 1 1 1_T � j �_ 1 z L 1 L I I 1 1 1 1- 1 L� rl ! I 1- 1 1 1 1_ -1 i _T ' 1-_ _T --1— I_I'I I . _ 1 1 -I�4 '1 1 I -�[� 1 i - 1 Z -T -7-1's �L I F 1 I L �L�-! � I J 1 I 1 1 1 -T T i T �rl r 1 1 i ' 1 -1 I -'-�: 1 ! _ F _C-1_i I '_ F 1 1 1 1J 1-T L-1 1" 1 -1-I 1 1 1 1 1 1 1 1 1j 1 1 1 J 1; 1 11 1_" -1 L J L 1 1 �i 1-1 l -L 1 T- 1 -1 _ I ! 1 _I__ T i 1 L 1 _L_1._1_ 1 1 7 1 1 I 1_1_ 1 1- T- T- 1 1 -T- I V I 1_ T- i 1— 1— __ 1 1 -7 1 T T ! 1 J) 1 L 1 13Rici( AP -1 l `L L __L_ I T 1 ^i 1- 1 L I W A. COYEDD_TOP -EDGEL L -- -1 I._. !� 1 1I T % � 1 J 1( 1_L 1 L[ 1 1 J 1 L L 1 1_ I I- I 1 1_ I I-1 -I 1 1 1 i 1 _._1.__ , , 1 1 LL' 1 LI 1-- �/- ..,'�n i- L �� l 1 I L 1 T f 1 ( �L- 1 �� 1 L I i 1 T� l l t_ L I t J -L t1 1 I L i ( 1- I 1 T L_ 1' lr 1 I \J T � 7 ,__H r 1 1 1 1 ! Si 1► �,�J! -[ ! 1 �T 1 i 1 !_ I L 1 1 1 1 1 1 1 1 1 i-I 1± 1 1 I! ! 1 1 I I I If _J_ �7 1 J 1 1 I T I i ! 1 T 1 I[ ( 1 T- 1 -T 1 1 L_ 1 .1 L _L_ 1 �\ —L J Z_L. T '_L_ T 1 I 1 _- [__. _G ! . —T ._ L ___l� 1�_ l _ ` 1 1 - I 1 I i--- 1 I 71:11 1 F7r I I I r 11 1 1 11 1 T i —r- i 1 I ! I �J1 I 1 1 1 12 1 1 1 IN. 1 -X -41X= STEEL VIBE- CHASES -FOR 1 1 1 -1 -I _ L L 1 L .L-LT1 1 1 1 I I J Ti)r 1 1 1 ��1 L TURF LINlr5 =PIC4t of 4 1- r Ti 1/ ! I_ 1 T 1 1- I. 11 _i_� -1 f 1 T- - L 1 1 _I 1_.. i L 1 _! i I T- 1 L l I ! 1 ^l�_ J _�'_ 1 _` I 1 1 i I 1 �I -\ 1 -1-- - I ! �-1 wTURE T�NAN SAS i.NEer l�P -� 1-1 1 T� 1 1 �Z �I isi L I J rT1 I �1 � i-Ll L 1% 1 TFaLCFF%�SE TO ROOFLTdP T_ LT 1 TYPIC EAT 41LOC�iT1• r 1 Z L L 1 T ) _I i ! T T L, � r- 1- -T � �T ! i 1 1 1 1 _i____■1 , L_ I _I- 1 L J-J l - i L-1 1-1 � I L (E) STONE BAND i l (E)iREE TO BE REMOVED PER PLAN I 1(E) BRIt:K1 `LTL �L�__�1-11-1 -! Tom( I � (E) STONE BAND 1 -1-- —11— - -T -1 __ -L -1- 1- - _t 1 1 I-� 1 1 1 1 C I --I 1 L i 1 1 J E i -T 1 -i -1 1 E L I -ELT-1-1-1 r 1 i 1 i 1_ _. �t_ __L -1 _1_ _ r _ -_ __ -r i _ _ 1 _I__. I. L _ 1 1 �5LL 1 1 - LI_ 1 1 L _1 1 I 1 1 1 - _ . T _ _ _._1 1 _._ I I L I_ _, _ 1 1 1_ 1 L T 1 1 11 ._ 1 1 _11 1-- -I __ -1- 1 L 1J- L 1 _ T [ L 1 ! T 1 I L 1r 1 -t .� -1- E = L L I- - -1 - -L .I-.-- 1 - -r 11- -1-- T --E-I 1 - -I -- 1-- T- 1-- [- /-- 1_.L --1 - - 1 ---1 1 -__I I----; 1 1 L 1 E 1 i L__1_11 __I 11 1T 1 r I I L 1 I I ` L __ _ F _ _ I 1 1 T' T _i__ L I _T 1 1 T L� [- Z 1 L� T- ,__� [- i (E) DOORTO TENANT SPACE i J'k`) DOOR TO i TENANT SPACE J u ■_I___ ■•__■I ■•1111=1111111111111111111 ■___._I IMMUNE L'—■ _- --_IIE =_■ _ _ _■ _� —• - -- - -'M _ --- - -. NMI 111M111•11111: 1f MP] _ X2171117wCt ll<R�!<7�_ESTIV!WIVIC R! ! <9.'�►Z14tR�!c7A�11iR�'<�I��li ? i�!► 1)It�lilA�!<�1.I�Z11lR��!<►1.u1 'mss► WOR'!c►11It�11172 MINI __41 !�1•_i1� 111'��� !' 1!:EC�k9t111l!AIVW. :41 MMIEISIM VAIR4 1,14111rG.WWI &V111IEgR 011 l i NLVV411'WATdi91'1E7! altirms_.'(■ NSW _IMMEI/MR ;► lT, r/ a>• �gI;�Ili1►dm�',r /_1�!��',I /�1.� V LI// 1\ 7i!S 4: 1/ �1 !��:LI /I�7��_:;7i� ►���:,I�,awn % /a��n?Ali//� ►►�V /Sl��`I tams■IIIIII ' G�-► 1�// ���/// �lIP%- i NMI M %11 WWI I��I:AN /11WiW111111/ %,111111111W411/ AINAWI 111 11 111/Nrir EMIR ■ IIM\1♦1111111111 c of.irawm iiisaw ihMiiszywurainav e Ji0lr &Amor autos , av111I iikunr i /i1/ iat:�P /��'Lt�l J L- SOMERSET CABLE TRELLIS TYPICAL OF 4 AT 4' -0" O.C. (E) TREE AND GRATE +10' -0" (E) GAS RISER TO REMAN EAST ELEVATION 1 /2" = 1' -0" 12 X 4 X 3/I6 STEEL TUBE PIPE CHASE - PAINT PIPE EXPOSED TO VIEW Its B.O. EXST. SOFFIT 10' -0" FUTURE TENANT GAS LINES (E) BRICK VENEER AND WALL ASSEMBLY BRICK VENEER OVER CMU WALL RE: WALL TYPE )AI' CONTINUOUS VERTICAL FLEXIBLE SEALANT JOINT FIRST LEVEL FF 0-0" (E) BRICK VENEER AND WALL ASSEMBLY (E) STONE BAND (E) SOFFIT CAP WITH D EDGES (E) BIKE RACK TO BE REMO AND RELOCATED TO SOUTH SIDE OF WESTFIELD ENTRY CONCRETE STEM WALL AND LANDSCAPING ■�I ■I ■I ■I ■ ■I ■I ■I ■I ■■ 0161 ■ ■1 ■ •■1 ■1 ■'1111111111 �1 __■•■1 __•■_• ms_■•_a _•_•_.1 ______ __IIIIM__1 ______ _____1 ______ • •■•__1 ______ __•111=1_1 ______ ___•■1 __1■1___ • •___•1 ____•_ __■•_1 ■■____ _1111111_!1_I _ili■ —___ _■__•1 ______ ■•__•I _■_■•_ ■__■_I __■•__ _I _•____ _____' •___•II 1— ■._ MIN WAN 1 NM ■IN /AM I. Ii MN IVO /A AN WAN GO_ 1 • rinn RAM Ilya 11/a IRMI A2.0 BENT PLA HASP WELDED T ' GATE AND WALL 61 CONCRE = MASONRY STEM WALL TO ATCH (E) STONE BAND - ICAL CONC 1 TE MASONRY STEM WALL TO MATCH (E) STONE BAND TYPICAL (E) STONE BAND 1 (E) FOUNDATION SOUTH ELEVATION 1/2" = 1' -0" STEEL BENT PLATE - TYPICAL AT EACH JAMB OF GATE r I L J STEEL GATE (PANTED - WARM STONE BY SHERWN WILLIAM ''1032 BRICK CAP WITH COVED EDGES (E) BRICK VENEER AND WALL ASSEMBLY (E) STONE BAND (E) SOFFIT 1111111ItWl ■1 ■1■1 ■1■ 111■ 1■ 1■ 1■ 1■ 1■ 1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 1_'a___________ _tom___•_■__•__ _I_■___________ rams___■■•__•_ tom___________ 1.1__________111111 _►a_____ NMI MIN _ms__ _I________1•111111___ ra•ms•■■■__•__ ■■1•■•__••■■_•• 11__■■■______ NMI _.__■■___•_•_ _I____________ om_•••_•_____ / 12 X 4 X 3/16 STEEL TUBE PIPE CHASE - PAINT PIPE EXPOSED TO VIEW CONCRETE FOUNDATION I RE: STRUCTURAL L J CONCRETE MASONRY STEM WALL TO MATCH (E) STONE BAND TYPICAL NORTH ELEVATION 1/2" = B.O. EXST. SOFFIT 10' -0" FUTURE TENANT GAS LINES (E) BRICK VENEER AND WALL ASSEMBLY BRICK VENEER OVER REINFORCED CMU WALL REINFORCED CONCRETE RE: WALL TYPE MASONRY WIT LIGHT BOLLARD OWNER RIRNISHED - CONTRACTOR NSTALLED BRICK VENEER OVER RE NFORGED CMU WALL TO MATCH (E) BRICK VENEER SEE WALL TYPE )5" CONTINUOUS VERTICAL FLEXIBLE SEALANT JONT FIRST LEVEL FF 0' -0" (E) FOUNDATION BRICK VENEER TO MATCH (E) BRI 3' -10 1/2" 1/4" 6" 6" 6" bit 6" $ 1 /4tH Y/ / / / / I r- e 0 GATE ELEVATION 1 /2" = 1' -0" s ilr A lj 2' X 9' X V4' PAINTED BENT PLATE HEAVY DUTY HINGE WELDED TO GATE AND FRAME (TYPICAL OF 4) GATE DETAIL *1—• XY ANCI•IOf25 AT 2' -0" O.C. TYPICAL S 1/4" 6' 6' 3'-10 1/2" B.O. EXST. SOFFIT 10' -0" (E) LINE OF SOFFIT FIRST LEVEL FF 0' -0" NOTES: L GATE IN ITS ENTIRETY, SHALL BE PRIMED AND PANTED 'WARM STONE' 4'1032 BY SHERWN WILLIAMS. 2. CONTRACTOR 51-1ALL GRIND SMOOTH ALL WELDING SLACK BURRS, AND NICKS FOR SMOOTH AND OBSTRUCTION FREE GATE N PREPARATION FOR FINAL PANT COATING. 3. MNIMUM CLEARANCE FOR GRASPING AT HANDLE SHALL BE Ili" CLEAR 2 x 2 X Y.4' VERTICAL STEEL ANGLES WELDED TO TOP AND BOTTOM STILE OF TUBE STEEL GATE (TYP. OF 5) 2J6" x 2Ji" X Y4" TUBE STEEL FRAME ALL AROUND 3/4" DIAMETER STEEL HANDLE WELDED TO TUBE STEEL GATE HEAVY DUTY STEEL HINGES (TYPICAL OF 4) 1ST LEVEL SLAB /SIDEWALK 0' -0" REINFORCED CONCRETE MASONRY UNIT EPDXY ANCHORS AT 2' -0" TYPICAL REVIEWED FO—R"--- CODE COMPLIANCE A PPER ED i 7 2011) City of Tukwila BUILDING Divicinm b(Ott7 , �I 0 1/4' 21/2 "X21/2 "X1 /4' TUBE STEEL FRAME - BOTTOM RAIL 1 1 /2" = 1' -0" 2X2X1/4' VERTICAL STEEL ANGLES WELDED TO TUBE STEEL FRAME (TYPICAL OF 5) VZ' GAP BUILDING PAPER FULLY ADHERED TO MASONRY BRIO: VENEER TO MATCH (E) BRICK X S. X 1/4' PAINTED BENT PLATE 2 I/2" X 2 1/2' X I/4" TUBE STEEL FRAME 3/4" DIAM. STEEL HANDLE UELDED TO TUBE STEEL GATE RECEIVED CITY OF TU KIM LA JUN 1 £t 2010 PERMIT CENTER Wesiliek! Sou th center 633 Southcantr Parkway TUkNq WA.. 98188 -2886 200- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRIAIENT OF SERVICE. IS THE PROPERTY CF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERNISSCN AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME ALL DESIGN AND OTHER HNFORMANON SHOWN ON 1W DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE VATHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 824 -2973 ISSUE z 0 i- < U LL 0 0 2 W 0 U -J W CW BOO W CO Z 0) W U < D .4C- 0 O 00 CV E- '\6/11/10 A5/24/10 ISSUE PERMIT SET DATE: MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ ELEVATIONS AND DETAILS A2.0 SMSA #1022.02 -r '�1 1 - r�J; -r Tr T I 1 � 1 1 i -1 i � T I -L L I 1 1 I I 1 1 t 1 1 i 1 I 1 i I I I r 1 J T 1 ,�/ --�� 7 i� 1! 1' 11 1 -1 r 1 1- 1 ,J^_ 1 ,_! I,� 1 ..... L.... _1 1 I II I ' T 1 �5LL 1 1 - LI_ 1 1 L _1 1 I 1 1 1 - _ . T _ _ _._1 1 _._ I I L I_ _, _ 1 1 1_ 1 L T 1 1 11 ._ 1 1 _11 1-- -I __ -1- 1 L 1J- L 1 _ T [ L 1 ! T 1 I L 1r 1 -t .� -1- E = L L I- - -1 - -L .I-.-- 1 - -r 11- -1-- T --E-I 1 - -I -- 1-- T- 1-- [- /-- 1_.L --1 - - 1 ---1 1 -__I I----; 1 1 L 1 E 1 i L__1_11 __I 11 1T 1 r I I L 1 I I ` L __ _ F _ _ I 1 1 T' T _i__ L I _T 1 1 T L� [- Z 1 L� T- ,__� [- i (E) DOORTO TENANT SPACE i J'k`) DOOR TO i TENANT SPACE J u ■_I___ ■•__■I ■•1111=1111111111111111111 ■___._I IMMUNE L'—■ _- --_IIE =_■ _ _ _■ _� —• - -- - -'M _ --- - -. NMI 111M111•11111: 1f MP] _ X2171117wCt ll<R�!<7�_ESTIV!WIVIC R! ! <9.'�►Z14tR�!c7A�11iR�'<�I��li ? i�!► 1)It�lilA�!<�1.I�Z11lR��!<►1.u1 'mss► WOR'!c►11It�11172 MINI __41 !�1•_i1� 111'��� !' 1!:EC�k9t111l!AIVW. :41 MMIEISIM VAIR4 1,14111rG.WWI &V111IEgR 011 l i NLVV411'WATdi91'1E7! altirms_.'(■ NSW _IMMEI/MR ;► lT, r/ a>• �gI;�Ili1►dm�',r /_1�!��',I /�1.� V LI// 1\ 7i!S 4: 1/ �1 !��:LI /I�7��_:;7i� ►���:,I�,awn % /a��n?Ali//� ►►�V /Sl��`I tams■IIIIII ' G�-► 1�// ���/// �lIP%- i NMI M %11 WWI I��I:AN /11WiW111111/ %,111111111W411/ AINAWI 111 11 111/Nrir EMIR ■ IIM\1♦1111111111 c of.irawm iiisaw ihMiiszywurainav e Ji0lr &Amor autos , av111I iikunr i /i1/ iat:�P /��'Lt�l J L- SOMERSET CABLE TRELLIS TYPICAL OF 4 AT 4' -0" O.C. (E) TREE AND GRATE +10' -0" (E) GAS RISER TO REMAN EAST ELEVATION 1 /2" = 1' -0" 12 X 4 X 3/I6 STEEL TUBE PIPE CHASE - PAINT PIPE EXPOSED TO VIEW Its B.O. EXST. SOFFIT 10' -0" FUTURE TENANT GAS LINES (E) BRICK VENEER AND WALL ASSEMBLY BRICK VENEER OVER CMU WALL RE: WALL TYPE )AI' CONTINUOUS VERTICAL FLEXIBLE SEALANT JOINT FIRST LEVEL FF 0-0" (E) BRICK VENEER AND WALL ASSEMBLY (E) STONE BAND (E) SOFFIT CAP WITH D EDGES (E) BIKE RACK TO BE REMO AND RELOCATED TO SOUTH SIDE OF WESTFIELD ENTRY CONCRETE STEM WALL AND LANDSCAPING ■�I ■I ■I ■I ■ ■I ■I ■I ■I ■■ 0161 ■ ■1 ■ •■1 ■1 ■'1111111111 �1 __■•■1 __•■_• ms_■•_a _•_•_.1 ______ __IIIIM__1 ______ _____1 ______ • •■•__1 ______ __•111=1_1 ______ ___•■1 __1■1___ • •___•1 ____•_ __■•_1 ■■____ _1111111_!1_I _ili■ —___ _■__•1 ______ ■•__•I _■_■•_ ■__■_I __■•__ _I _•____ _____' •___•II 1— ■._ MIN WAN 1 NM ■IN /AM I. Ii MN IVO /A AN WAN GO_ 1 • rinn RAM Ilya 11/a IRMI A2.0 BENT PLA HASP WELDED T ' GATE AND WALL 61 CONCRE = MASONRY STEM WALL TO ATCH (E) STONE BAND - ICAL CONC 1 TE MASONRY STEM WALL TO MATCH (E) STONE BAND TYPICAL (E) STONE BAND 1 (E) FOUNDATION SOUTH ELEVATION 1/2" = 1' -0" STEEL BENT PLATE - TYPICAL AT EACH JAMB OF GATE r I L J STEEL GATE (PANTED - WARM STONE BY SHERWN WILLIAM ''1032 BRICK CAP WITH COVED EDGES (E) BRICK VENEER AND WALL ASSEMBLY (E) STONE BAND (E) SOFFIT 1111111ItWl ■1 ■1■1 ■1■ 111■ 1■ 1■ 1■ 1■ 1■ 1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 1_'a___________ _tom___•_■__•__ _I_■___________ rams___■■•__•_ tom___________ 1.1__________111111 _►a_____ NMI MIN _ms__ _I________1•111111___ ra•ms•■■■__•__ ■■1•■•__••■■_•• 11__■■■______ NMI _.__■■___•_•_ _I____________ om_•••_•_____ / 12 X 4 X 3/16 STEEL TUBE PIPE CHASE - PAINT PIPE EXPOSED TO VIEW CONCRETE FOUNDATION I RE: STRUCTURAL L J CONCRETE MASONRY STEM WALL TO MATCH (E) STONE BAND TYPICAL NORTH ELEVATION 1/2" = B.O. EXST. SOFFIT 10' -0" FUTURE TENANT GAS LINES (E) BRICK VENEER AND WALL ASSEMBLY BRICK VENEER OVER REINFORCED CMU WALL REINFORCED CONCRETE RE: WALL TYPE MASONRY WIT LIGHT BOLLARD OWNER RIRNISHED - CONTRACTOR NSTALLED BRICK VENEER OVER RE NFORGED CMU WALL TO MATCH (E) BRICK VENEER SEE WALL TYPE )5" CONTINUOUS VERTICAL FLEXIBLE SEALANT JONT FIRST LEVEL FF 0' -0" (E) FOUNDATION BRICK VENEER TO MATCH (E) BRI 3' -10 1/2" 1/4" 6" 6" 6" bit 6" $ 1 /4tH Y/ / / / / I r- e 0 GATE ELEVATION 1 /2" = 1' -0" s ilr A lj 2' X 9' X V4' PAINTED BENT PLATE HEAVY DUTY HINGE WELDED TO GATE AND FRAME (TYPICAL OF 4) GATE DETAIL *1—• XY ANCI•IOf25 AT 2' -0" O.C. TYPICAL S 1/4" 6' 6' 3'-10 1/2" B.O. EXST. SOFFIT 10' -0" (E) LINE OF SOFFIT FIRST LEVEL FF 0' -0" NOTES: L GATE IN ITS ENTIRETY, SHALL BE PRIMED AND PANTED 'WARM STONE' 4'1032 BY SHERWN WILLIAMS. 2. CONTRACTOR 51-1ALL GRIND SMOOTH ALL WELDING SLACK BURRS, AND NICKS FOR SMOOTH AND OBSTRUCTION FREE GATE N PREPARATION FOR FINAL PANT COATING. 3. MNIMUM CLEARANCE FOR GRASPING AT HANDLE SHALL BE Ili" CLEAR 2 x 2 X Y.4' VERTICAL STEEL ANGLES WELDED TO TOP AND BOTTOM STILE OF TUBE STEEL GATE (TYP. OF 5) 2J6" x 2Ji" X Y4" TUBE STEEL FRAME ALL AROUND 3/4" DIAMETER STEEL HANDLE WELDED TO TUBE STEEL GATE HEAVY DUTY STEEL HINGES (TYPICAL OF 4) 1ST LEVEL SLAB /SIDEWALK 0' -0" REINFORCED CONCRETE MASONRY UNIT EPDXY ANCHORS AT 2' -0" TYPICAL REVIEWED FO—R"--- CODE COMPLIANCE A PPER ED i 7 2011) City of Tukwila BUILDING Divicinm b(Ott7 , �I 0 1/4' 21/2 "X21/2 "X1 /4' TUBE STEEL FRAME - BOTTOM RAIL 1 1 /2" = 1' -0" 2X2X1/4' VERTICAL STEEL ANGLES WELDED TO TUBE STEEL FRAME (TYPICAL OF 5) VZ' GAP BUILDING PAPER FULLY ADHERED TO MASONRY BRIO: VENEER TO MATCH (E) BRICK X S. X 1/4' PAINTED BENT PLATE 2 I/2" X 2 1/2' X I/4" TUBE STEEL FRAME 3/4" DIAM. STEEL HANDLE UELDED TO TUBE STEEL GATE RECEIVED CITY OF TU KIM LA JUN 1 £t 2010 PERMIT CENTER Wesiliek! Sou th center 633 Southcantr Parkway TUkNq WA.. 98188 -2886 200- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRIAIENT OF SERVICE. IS THE PROPERTY CF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERNISSCN AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME ALL DESIGN AND OTHER HNFORMANON SHOWN ON 1W DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE VATHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 824 -2973 ISSUE z 0 i- < U LL 0 0 2 W 0 U -J W CW BOO W CO Z 0) W U < D .4C- 0 O 00 CV E- '\6/11/10 A5/24/10 ISSUE PERMIT SET DATE: MAY 4, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ ELEVATIONS AND DETAILS A2.0 SMSA #1022.02 C\RAL \OTES THE FOLLOWING NOTES APPLY EXCEPT WHERE SHOWN OTHERWISE CODE International Building Code (IBC) 2006 STRUCTURAL LOADS WIND LOADS: EARTHQUAKE LOADS: Basic wind speed, V3s = 85mph Wind importance factor, Iw = 1.00 Wind exposure: 'C' Internal pressure coefficient = 0.18 Kzt =1.0 Seismic Occupancy category II Seismic importance factor, le = 1.00 Mapped accelerations, Ss = 1.424 S1 = 0.488 Site class = D Design accelerations, Sds = 0.85 Sd1 = 0.78 Seismic design category: D SHOP DRAWINGS Shop drawings shall be submitted for review prior to fabrication. Shop drawing submittals processed by the engineer are not change orders. The purpose of shop drawing submittals by the contractor is to demonstrate to the engineer that the contractor understands the design concept, by indicating which material is intended to be furnished and installed, and by detailing the intended fabrication and installation methods. If deviations, discrepancies, or conflicts between shop drawing submittals and the contract documents are discovered either prior to or after shop drawing submittals are processed by the engineer, the design drawings and specifications shall control and shall be followed. FOUNDATIONS Maximum soil pressure 2000 psf. Exterior footings shall bear 1' -6" (minimum) below finish grade. All footings to bear on firm undisturbed earth below organic, surface soils and shall be lowered if suitable soil is not found at elevations shown on drawings. Backfill to be thoroughly compacted per specifications. provide 2 #5 (minimum) continuous bottom of all walls and footings. CONCRETE Footings and foundation walls Slabs on grade Masonry poured grout in lintels, bond beams and cells MAX WATER /CEMENT RATIO f'c NON- AIR -ENT AIR -ENT 2500 0.65 0.54 3000 0.58 0.46 2500 0.65 MINIMUM SACKS /C.Y. 5-1/2* 5 -1/2 0.54 5 1. Air - entraining agent (3% to 6 %) to be used in all concrete flatwork exposed to weather. * Can be reduced 1/2 sack /cubic yard if not exposed to weather. REMARKS Note 1 Y" max aggregate REINFORCING STEEL ASTM A615 grade 60. Reinforcing steel details shall be prepared by an experienced detailer and conform to standard practice outlined in ACI Report 315. Field welding or tack welding of reinforcing bars is prohibited, except as approved by the Engineer. Any reinforcing to be welded to be ASTM A706, weldable grade. When approved, welding of reinforcing bars to be per AWS D1.4. • Mechanical splice devices, if required, shall be ICC approved and shall be submitted to the engineer for approval. Reinforcing bars shall be lap spliced for tension unless noted otherwise on the drawings. #14 and larger bars shall not be lap spliced. Lap foundation reinforcing 32 diameters. Other lap lengths per drawings. Welded Wire Fabric to be ASTM A185. Fabric to be supported on approved chairs. NOTE:Reinforcing steel not specifically shown shall be assumed typical as similar sections and details where reinforcing is shown. CONCRETE COVER OF REINFORCING 3" 2" 1 -1/2" 1" 3/4" Concrete poured against earth. Formed concrete with earth backfill. Beams and columns (stirrups, ties), outside face of walls exposed to weather, slabs on moisture barrier. Walls, inside face. Formed slabs. ANCHORAGE TO HARDENED CONCRETE Where expansion anchors are specified, use "Hilti Kwik Bolt TZ" (reference ICC Report ESR- 1917.) Where epoxy anchors are specified, use "Hilti HIT -RE 500 -SD" OR "Simpson SET -XP" (reference ICC Report ESR -2322 and ESR- 2508). Where screw anchors are specified, use "Simpson Titen HD" (reference ICC report ESR- 2713). "Hilti HIT -RE 500 ", " Hilti HY- 150 ", And "Simpson SET" may not be used, unless specifically pre- approved by the StructuraL Engineer. Use ASTM A193 Grade B7 threaded rod, unless otherwise noted. Holes must be cleaned of dust and debris and be free of standing water when epoxy is installed. Special inspection of epoxy anchors is required. Do not cut any reinforcing bars to install anchors. Defective holes shall be filled solid with epoxy. For any substitutions to the above, the contractor shall submit to the Structural Engineer manufacturer's literature describing the anchors and listing ICC approved allowable shear and tension values. CONCRETE MASONRY The minimum compressive strength (design strength -f'm) of the concrete masonry shall be 1500psi. Concrete masonry units shall be medium weight (115 PCF) with a minimum net area compressive strength of 1900psi. All units shall conform to ASTM C55 or C90 and shall be sampled and tested in accordance with ASTM C140. Only type 'S' mortar shall be used. The mortar shall conform to ASTM C270 and the current IBC. Thickness of the bed joints shall not exceed 5/8 ". The grout shall conform to ASTM C476 and shall have compressive strength equal to or higher than f'm and shall not be less than 2000psi. The compressive strength of the grout shall be determined in accordance with ASTM C1019. Where the masonry does not meet the above requirements, the compressive strength of the masonry shall be determined by the prism test method per the current IBC and ACI530. Masonry construction shall comply with the provisions of the current IBC and ACI 530 /ASCE 6 /TMS 602. Cells containing reinforcing bars shall be grouted. Bar positioners shall be used at 4'o.c. for all vertical reinforcement. Special inspection is required. Anchor bolt material shall be ASTM A307 or A36 rods. Headed or bent bar anchors may be used. Anchors shall be embedded in fully grouted cells. Minimum cover shall be 2 �� times anchor diameter. A bent bar anchor shall be hooked around a reinforcing bar and a reinforcing bar shall be hooked around a headed anchor. BRICK MASONRY VENEER Brick masonry veneer anchorage shall meet all requirements of ACI 530 /ASCE 5 /TMS 402 chapter 6. Anchor ties shall be corrosion resistant, and shall have a minimum thickness of No. 22 gauge (0.03 inches) by 7/8 inch wide or, if of wire, shall be a minimum diameter of W1.7 (0.147 inches) with 2 inch bend extensions. Anchor ties shall extend into the veneer a minimum of 1.5 inches with at least a 5/8 inch mortar cover to outside face. Anchor ties shall be spaced so as to support not more than 2 square feet of wall area but not more than 32 inches on center horizontally and 18 inches on center vertically. Horizontal joint reinforcement of ladder or tab type wire shall be provided. Anchor ties shall have a lip or hook on the extended leg that will engage or enclose a . horizontal joint reinforcement wire of W1.7 diameter or equivalent. The joint reinforcement shall be continuous with butt splices between ties permitted. When applied over wood or light gauge stud construction, the studs shall be spaced a maximum of 16 inches on centers and approved paper shall first be applied over the sheathing or wires between studs. An air space of at least 1 inch must be maintained between the backing and the veneer in which case temporary spot bedding may be used away from the ties to align the veneer. Spot bedding at the ties shall be of cement mortar entirely surrounding the ties. STRUCTURAL STEEL HSS structural tube to be ASTM A500, grade B, Fy =46 ksi. All steel except steel embedded in concrete shall be given one shop coat of approved paint. Welds to be 3/16" minimum continuous fillet, by certified welders using E70xx electrodes. All welding shall be performed in strict adherence to a written welding procedure specification (WPS) per AWS D1.1. All welding parameters shall be within the electrode manufacturer's recommendations. Welding procedures shall be submitted to the owner's testing agency for review before starting fabrication or erections. Copies of the WPS shall be on site and available to all welders and the special inspector. Anchor bolts embedded in concrete or masonry are ASTM F1554 Grade 36, unless otherwise noted. Use headed anchor bolts, not "J" bolts. Do not enlarge holes in base plate by burning. Bending of anchor bolts is permitted only with the prior approval from the engineer. High strength anchor bolts to be ASTM F1554, A354, or ASTM A193 Grade B7, minimum yield strength per drawings. No welding to or bending of high strength anchor bolts is permitted. Submit shop drawings prepared by an experienced detailer for review prior to fabrication. Shop drawings to be complete, showing all welds and material grades. Provide a plan location or detail reference for each shop drawing. For minor steel -to -steel connections of 12" and smaller steel members: If an explicit connection is not shown on the structural drawings, detailer is to propose a connection similar to the connections on the drawings or per AISC standard connections. On the shop drawing, cloud the connection and state "verify: Shop drawings not meeting these conditions will be rejected. Review of shop drawings by the Engineer is for design intent only, and does not include verification of dimensions and quantities. Verification of dimensions and quantities are the responsibility of the contractor. Steel Fabricators and Detailers: Base bid to include steel detailer and fabricator time and costs for routine construction questions. Routine construction questions include dimensional questions and minor framing questions. Routine construction questions are part of the normal construction process, and are to be included in the base bid. COLD FORMED STEEL (CFS) Cold formed carbon or low -alloy steel framing members shall be manufactured by a member of the Steel Stud Manufacturers Association, SSMA, and shall comply with ICC report ER- 4943P. All material shall be galvanized and conform to ASTM A653. All 12, 14, and 16 gauge (97, 68 and 54 mils thick, respectively) material shall be Grade 50 (fy= 50 ksi). All 18, 20, 22, and 25 gauge (43, 33, 27 and 18 mils thick, respectively) material shall be Grade 33 (fy = 33 ksi). The design, installation and construction of load- bearing and non load- bearing steel framing shall be in accordance with the current AISI Specification. Minimum thickness of top & bottom wall track and blocking shall be at least the same gauge as the wall studs attached to it. COLD FORMED STEEL (CFS) CONNECTORS Screws shall be self - drilling, thread - cutting tapping screws conforming to SAE J78, with ICC approval. Penetration of screws through joined materials shall not be less than 3 exposed threads. Maximum screw spacing shall be no greater than 12" oc. Where plans and details specify #8, #10 & #12 screws, they shall have the following properties: #8 = 0.164" dia., 12 threads /inch (8 -12) #10 = 0.190" dia., 16 threads /inch (10 -16) #12 = 0.216" dia., 14 threads /inch (12 -14) Welding of CFS framing shall conform to the requirements of AWS D1.3 and shall be performed by a welder certified in accordance with AWS D1.3. Use E60xx electrodes. Powder - actuated or low- velocity driven fasteners shall be Hilti "X -DNI" or "DS" connecting CFS to concrete, or Hilti "X -EDNI" or "DS" connecting CFS to structural steel, unless noted otherwise. All substitutions shall have the written approval of the engineer of record prior to use. SCOPE OF STRUCTURAL ENGINEERING SERVICES The Structural Engineer has performed the structural design and prepared the structural working drawings for this project. The construction must be performed in strict accordance with the structural drawings. Any deviation from the drawings must be approved in writing by the Structural Engineer. Errors and /or omissions found on the structural drawings must be brought to the Structural Engineer's attention immediately. Architectural drawings are the prime contract drawings. Structural drawings shall be used in conjunction with Architectural drawings. Primary structural elements are dimensioned on the Structural plans and details. The General Contractor shall verify and coordinate dimensions among all drawings. Any discrepancies, contradictions, or omissions shall be reported to the Architect for resolution prior to proceeding with work or fabrication of the item(s) in question. The Structural Engineer is responsible for the design of the primary structural system, except for any components noted above. Responsibility for any secondary structural and non - structural systems not shown on the structural plans rests with someone other than the Structural Engineer. The structure shown on these drawings is structurally sound only in its completed form. The Contractor shall provide all necessary bracing to stabilize the building during construction. The Structural Engineer is not responsible for, and will not have control of, construction means, methods, techniques, sequences or procedures, or for safety precautions and programs in connection with the construction work, nor will he be responsible for the Contractor's failure to carry out the construction work in accordance with the contract documents. Field measurements and the verification of field dimensions are not part of the Structural Engineer's responsibility. The Contractor must check all (assumed) existing conditions shown on these drawings for accuracy and notify the Structural Engineer of any discrepancies. Omissions from the drawings or specifications or the inadvertent mislabeling of details of work which are manifestly necessary to carry out the intent of the drawings and specifications, or which are customarily performed, shall not relieve the Contractor from performing such omitted or inadvertent mislabeled details of the work but they shall be performed as if fully and correctly set forth and described in the drawings and specifications. REVIEWED FOB CODECOMPLIANCE AP I+" r�' n Pero Ji' 17 2010 City of Tukwila BUILDING Unricrnht bOt1 CITYO�TUKIMLA MAY •0 5 2010 PERMIT CENTER SIRES 01/09/2011 PETERSON S TREHLE ■ LRTINSON, INC. CONSULTING ENGINEERS 2200 6TH AVE SUITE 601 SEATTLE, WA 98121 -1849 pem ®pexn- engineers. oom PHONE (206)622 -4680 FAX (208)622 -0422 WstIle[tf Southcenter 633 Southcenter Parkway Tukwila, WA., 96188 -2686 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAYVNG IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY CF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION M0 UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESIGN MD O7HER INFORMATION SHOWN ON THE DRAWNG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WTHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 824 -2777 • FAX (208) 824 -2973 4220 REGISTERED 1 ARCHITECT SCOTT M. STEMPER STATE OF WASHINGTON ISSUE ISSUE DATE: W Z 0, W 0 < D < 0 J O co H N PERMIT SET OCT. 8, 2009 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ GENERAL NOTES SMSA #1022.02 5PECAL I \SP= CTIO \S QUALITY ASSURANCE PLAN The Quality Assurance Plan includes all Special Inspections & Testing listed below. CONTRACTOR RESPONSIBILITY Each contractor responsible for the construction of the structure, or for any component requiring testing or special inspections, shall submit, prior to construction, a letter which includes: 1. Acknowledgement by the contractor of the quality assurance plan. 2. Acknowledgment that control will be exercised to obtain conformance with the construction documents approved by the building official. 3. Procedures for exercising control within the contractor's organization, and methods and frequency of reporting and distribution of the report. 4. Identification and qualifications of the person(s) exercising such control and their position(s) within the organization. This letter is to be submitted and approved prior to construction. SPECIAL INSPECTIONS — GENERAL Special Inspector provide special inspections with the type and frequency noted below. Special Inspector to provide reports weekly to: 1. The Owner 2. The Architect 3. The Structural Engineer 4. The Contractor STRUCTURAL TESTING — GENERAL Testing Agency to provide reports of the types below. Testing agency to distribute reports to: 1. The Owner 2. The Architect 3. The Structural Engineer 4. The Contractor SPECIAL INSPECTIONS — CONVENTIONAL (SHALLOW) FOUNDATIONS ELEMENT: Continuous Concrete Footings fully supported on rock or soil PERIOD: Not required (IBC 1704.1.2) SPECIAL INSPECTIONS — CONCRETE CONSTRUCTION ELEMENT: Bolts in Concrete, including embedded bolts, and expansion and epoxy type anchors. PERIOD: Continuous Special Inspection: Special Inspector verify size, grade, and embedment of bolt prior to pouring concrete. Verify hole is correct depth and clean for epoxy and expansion type anchors. ELEMENT: Slabs on grade PERIOD: Special Inspection not required. SPECIAL INSPECTIONS — STRUCTURAL STEEL CONSTRUCTION ELEMENT: Welding Procedure PERIOD: All welding shall be performed in strict adherence to a written welding procedure per AWS D1.1. The welding procedure variables shall be within the parameters established by the filler metal manufacturer. The variables include the amperage, voltage, travel speed, and shielding gas flow rate. Submit welding procedure for approval prior to beginning work. A copy of the welding procedure shall be kept at the jobsite. ELEMENT: Welder Certification PERIOD: Special Inspector to verify welder qualifications for type of welds and welding positions prior to work ELEMENT: Welding Materials PERIOD: Special Inspector to verify materials meet the welding procedure prior to work ELEMENT: Shop Welding PERIOD: Special Inspections are not required where the fabricator is registered and approved to perform such work without special inspection. Approval shall be based upon review of the fabricator's written procedural and quality control manuals and periodic auditing of fabrication practices by an approved special inspection agency. At completion of fabrication, the approved fabricator shall submit a certificate of compliance to the building official stating that the work was performed in accordance with the approved construction documents. ELEMENT: Welding of light —gage, cold— formed members PERIOD: Special Inspector to provide Visual Inspection of all welds prior to completion SPECIAL INSPECTIONS — LEVEL 1 (NON— ESSENTIAL) CONCRETE MASONRY UNITS (CMU) ELEMENT: Beginning of masonry construction PERIOD: Special Inspector to verify foundation dowels, proportions of site — prepared mortar, construction of mortar joints, and location of reinforcing and connectors. ELEMENT: Masonry structural element size and location PERIOD: Periodic Special inspection ELEMENT: Protection of masonry during cold weather (below 40 degrees F) or hot weather (temperature above 90 degrees F) PERIOD: Periodic Special Inspection ELEMENT: Size, grade, and location of steel reinforcing PERIOD: Special Inspector to verify prior to pouring of grout. ELEMENT: Anchors in CMU PERIOD: Periodic Special Inspection. Special Inspector to verify type, size, and location of anchors, or any anchorage between CMU wall and other structural elements. ELEMENT: Construction of Mortar Joints PERIOD: Periodic Special Inspection. ELEMENT: Grout Space PERIOD: Special Inspector to verify that grout space is clean, that reinforcing and connectors are correctly placed, the proportions of site — prepared grout, and construction of mortar joints. Special Inspector to verify these items before pouring of grout. ELEMENT: Placement of grout PERIOD: Continuous Special Inspection ELEMENT: Welding of reinforcing steel PERIOD: Continuous Special Inspection ELEMENT: Preparation of required grout specimens, mortar specimens, and /or prisms PERIOE: PERIOD: Continuous Special InspectionlANCE TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. REVIEWED FOI3 CODE COMPLIANCE JUN 17 2010 City of Tukwila BUILDING DIVISION t), CI1Y ORKVNLA MAY 0 5 2010 PERMIT CENTER EXPIRES 01/09/2009 PETERSON S TREHLE ILRTINSON. INC. CONSULTING ENGINEERS 2200 8TH AVE SUITE 801 SEATTLE. WA 98121 -1849 p ern ®perm — a ngine ere. a om PHONE (208)822 -4680 FAX (208)622 -0422 WslIle[tf Southcenter 633 Southcenter Parkway Tukwila, WA., 98188 -2888 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE. IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 824 -2777 • FAX (208) 624 -2973 120 REGISTERED I ARCHITECT SCOTT M. STEMPER STATE OF WASHINGTON ISSUE ISSUE DATE: op Wes, o0 Z O) W U < E- M Q O J O 000 CV E' PERMIT SET OCT. 8, 2009 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ SPECIAL INSPECTION S1.1 SMSA #1022.02 EXIST. EXTERIOR WALL ASSEMBLY TO REMAIN TENANT GAS METERS AND MANIFOLD RE: PUGET SOUND ENERGY " " AIN 1 5" SLAB ON GRADE \ W / #4 @16 "OCEW :� :A 11 : 01 () O () 1 O () () O 1 FLOOR PLAN SCALE: 1 /2" = 1 ' -0" OUTLINE OF SOFFIT ABOVE 8" CMU WALL SECTIOIN SCALE: 1 / 2" = 1 ' - 0" L4 x 4 x 12GA x AS REQD. W/ (2) # 12 SCREWS TO 3 DECK FLUTES. (3) # 12 SCREWS TO HSS. (TYP EA.SIDE) •1 •d• . • - . . HSS 12 x 4 x 3�s SEE ARCHT PLAN FOR LOCATIONS L4 x 4 x 12GA x AS REQD. W/ (2) # 12 SCREWS TC 3 DECK FLUTES. (3) # 12 SCREWS TO HSS. (TYP EA.SIDE) (E) ROOF DECK HSS 12 x 4 x 3/8 HSS 12 x 4 TO ( E ) ROOF DECK CONNECTIO NTS (E) WALL CAP PER ARCHT (2) #4 CONT HORIZ AT TOP w a BRICK VENEER PER ARCHT (2) #4 CONT HORIZ AT 32" OC #5 VERT AT CL AT 24" OC, BEND INTO FTG #4 x 1' -0" @ 2' -0" OC EMBED 3" INTO EXIST FTG W /RE 500 SD #4 AT 12" OC 2 -6 —11 -0 (2) #4 CONT AT BASE FIN GRADE (E) AG SECTION NTS #4 AT 18" OC EACH WAY 1' -5" 8" 1' -5" i 3' -6" (3) #6 CONT 8"± — (E) WALL STUDS " M HSS 12 x 4 x %6 PASS BTWN (E) SOFFIT FRAMING L4 x 4 x 12GA RG.SIDE W/ (4) # 12 SCREWS TO HSS (2) # 12 SCREWS TO EA.STUD 800S200 -54 ON EA.SIDE OF HSS, (MAX SPACING 32 ") ATTACH TO (E) WALL STUDS W /(6) # 12 SCREWS ` (E) SOFFIT FRAMING (E) BRICK VENEER HSS 12 x 4 TO ( E ) WALL STUD CONNECTION NTS REVIEWED FOR CODE COMPLIANCE jam,11. 7 2010 � Tukwila City of T u BUILDING DIvi tnial t)10-.1r1 ci4OFT6F<WitA MAY •0 5 2010 PERMIT CENTER EXPIRES 01 /09/2011 PETERSON S TREHLE lRTINSON, INC. CONSULTING ENGINEERS 2200 BTH AVE SUITE 801 PHONE (206)622 -4580 SEATTLE, WA 98121 -1849 FAX (208)622 -0422 psm ®psm — engineers.com WESTFIELLLDBouD DESIGN & W E 11601 t v 11th Floor L�a�� California Telephone 310 478 4466 Faoinll. 310 478 4488 THIS aura !8 NI DISIRIAINT CF B n rtflifffx1Y ff n ? IECT NO WY NOT 9E RORODUCm �MQ 1}€ POi6�a01 NO Ut 7{E RFPRD➢JC1UI CAICEI 7E ARCIitFIIIE NNE NL 06701 AND O11E11pgWpOI�WIaOII�lal OM UE OiU1N N! O�1N mATPFANS90N� g L1H AR 41 S.M. STEMPER ARCHITECTS . Professional limited liability Company 4000 DEIRIDOIS WAY 81 sms IMO • e1.'1 TA 08106 (200) 024 -2777 • FAX (200) 1e24 -2075 REGISTREDARMECT \200TT M. SIPE OF 1 ISSUE ISSUE DATE: PERMIT SET OCT. 8, 2009 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ PLANS AND DETAILS S2.0 SMSA #1 022.02