HomeMy WebLinkAboutPermit D10-128 - 295 FIDELITY BUILDING295 FIDEUTY BUILDING 5920 S 180 ST D10 -128 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D10 -128 Issue Date: 06/02/2010 Permit Expires On: 11/29/2010 Tenant: Name: 295 FIDELITY BUILDING Address: 5920 S 180 ST , TUKWILA WA Owner: Name: BOEING OREGON MASABI TRUST Address: 1325 4TH AVE SUITE 1940 , SEATTLE WA 98101 Phone: Contact Person: Name: ROOF DOCTORS, ATTN DAVE Address: PO BOX 48321 , SEATTLE WA 98166 Phone: 206 243 -5637 Contractor: Name: DGK ENTERPRISES Address: 17404 MERIDIAN E STE F , PUYALLUP WA 98375 Phone: 253 864 -7011 Contractor License No: DGKENEI942OF Expiration Date: 09/06/2010 DESCRIPTION OF WORK: TEAR OFF ROOF, CHECK FOR BAD DECKING, AND REPLACE AS NEEDED. MECHANICALLY FASTEN 1/4 DECK AND 3.9" AT 21 POLY - R50 INSULATION INSTALL 50 ML PVC SYSTEM Value of Construction: $337,500.00 Fees Collected: $5,672.91 Type of Fire Protection: SPRINKLER /AFA International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -7/07 D10 -128 Printed: 06 -02 -2010 City of Tukwila � y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10 -128 Issue Date: 06/02/2010 Permit Expires On: 11/29/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: Private: Profit: N Private: N Public: Non - Profit: N Public: Date: nLIAD21 4 I hereby certify that I have read and : ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie •, whether specified herein or not. The granting of this permit does not pre • e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc • work. I am authorized to sign and obtain this development permit. Signature: _ �V Date: 67 0. Print Name: N2-t.,12 T Z� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -7/07 D10 -128 Printed: 06 -02 -2010 t City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. / /www.ci.tukwila.wa.us Parcel No.: 3523049105 Address: Suite No: Tenant: 5920 S 180 ST TUI{W 295 FIDELITY BUILDING PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10 -128 ISSUED 05/17/2010 06/02/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi - purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D10 -128 Printed: 06 -02 -2010 1"-- w City of Tukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Date: ordinances governing or local laws regulating doc: Cond -10/06 D10 -128 Printed: 06 -02 -2010 CITY OF TUK...LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.ci.tukwila.wa.us Building Pennit No. t2 \ 11- Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: ,_ ; 2c 7 5 /"i Tenant Name: - Gl /1",-; Property Owners Name: 4-11--2?-1.--" r t TL �j'v a j hi (2 King Co Assessor's Tax No.: 12 1/"l — el c Suite Number: Floor: New Tenant: ❑ Yes ❑..No Mailing Address: /3 li"�'i^fr City 't-5-41 State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued � re / Name: yt - `, '5c AA. ;. l Mailing Address: 947 0 . 7/ E -Mail Address: Qc. 4 ditA/r s t�th7; Day Telephone:.G City State Zip Fax Number: `' /c/ GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name `iJ (, /C tr f J 'c_ 'n a hl ;Ltcvi- t?r Mailing Address: X 0 /3 ex" Contact Person: y,z/ E -Mail Address: f 'e f ci /fares c' «, ✓t , . iy Contractor Registration Number: V €' r✓cr.. j 1 r` City State Zip Day Telephone „�it� - '/3 - - 6.1 7 Fax Number: rj" `2'13.5 - Expiration Date: 9— H - ci Cf ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name:_ Mailing Address: Contact Person:_ �3 �� 5 /62, /z `c. Day Telephone E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Z CV's" q tr /� ?�l "�i s`'' ° %- Contact Person:_ fif ' .34w.0/(4. %I;74 L City State aip Day Telephone: ,-5"0 y" E -Mail Address: Fax Number: H \Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised. 1 -2009 bh Page 1 of 6 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 33` 5—go, Existing Building Valuation: $ Scope of Work (please provide detailed information): ti } Ltt SZ960, e ff 4 reez- e y f l /- j172re141 / ✓C,4-/ i % &44S' a : 3 y // ' z 0 #54 At 7` %V / Nf -a 0,2 Re/d- goejloCA, Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ja Sprinklers tSr Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes ', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:WpplicationsWorms- Applications On Line\2009 Applications \I -2009 - Permit Application. doc Revised' 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1g' Floor 0q V 10 r� U ib rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ja Sprinklers tSr Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes ', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:WpplicationsWorms- Applications On Line\2009 Applications \I -2009 - Permit Application. doc Revised' 1 -2009 bh Page 2 of 6 PERMIT APPLICATION, l OTES;= Applicable to °allvpermtsnrn`�th s a pltgat on Value of Construction — In all cases, a value of construction amount sliould be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR tTHORIZED AGENT: Signature: Date: /777 64 // a53 "77 r4, Day Telephone: d206--V f33 Zip Print Name: V5l42-11( -' rir C/2/ 1c.Jc— Mailing Address: 5't dioit LVf-yZ l City state Date Application Accepted: t si n Ito Date Application Expires: 1 16 M t [1 Staff Initials: i ic � H:\Applications\Forms - Applications On Line \2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 PLUMBING AND GAS PIPIN I� FORIVIATI� PLUMBING AND GAS PIPING CONTRACTOR INFORMATI Company Name: Mailing Address: 6 =431 City State Zip Contact Person: E -Mail Add s: Contractor Regi ation Number: Telephone: Fax mber: Expiratio P ate: Valuation of Project (con ct.." s bid price): $ Scope of Work (please pr detailed information): : r Buildin: . se (per Int'l Building Code): Occ cy (per lnt'l Building Code): I ity Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas pip'; outl u being installed and the quantity below: Fixture Type: Qty Fixture Ty , : r` _; • Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drin. -''g fountain or w..` cooler (per head) . ;d -waste grinder, com t rcial Floor Drain Shower, single head trap vatory Wash ` "< ntain Receptor, indirect was Si r Urinals Water C1os= , Building sew .. d each trailer p. -z-wer Rain water " -tem — per drain (inside b • sing) Water heater and/or vent Industrial waste "•: atment interceptor, include trap and vent, except for '` hen type grease interceptor ' ,, " Each : -'ase trap ected to not more , >' an 4 fixtures - <750 gallon capacity) Grease interceptor . r commercial kitc n ( >75 i gallon capaci• Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping . ,'' Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each ad•' onal medical gas inl> /outlets greater th. Backflow protective _. vice other than at �.,-, pheric -type vacuum break =', 2 inch (51 mm) diamete '�, smaller Backflow prote ,v`»e device other than a .;. spheric -type vacuum b ,-. ers over 2 inch (5 ' m) diameter Each lawn sprinkler ystem on any one meter '. luding backflow prt ection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmosphere .4 pe vacuum break-'-‘, not included in lawn'' sprinkler backflow protections over 5 piping outlets H:\Applications\Porms- Applications On- Line12009 Applications)] -2009 Permit Application,doc Revised, 1 -2009 bh Page 5 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: Applicant: 295 FIDELITY BUILDING RECEIPT Permit Number: D10 -128 Status: APPROVED Applied Date: 05/17/2010 Issue Date: Receipt No.: R10 -00973 Payment Amount: $3,439.90 Initials: JEM Payment Date: 06/02/2010 10:50 AM User ID: 1165 Balance: $0.00 Payee: DGK ENTERPRIESE INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12365 3,439.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $3,439.90 3,435.40 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -02 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http.• / /www.ci.tukwila.wa.us Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: Applicant: FIDELITY BUILDING RECEIPT Permit Number: D10 -128 Status: PENDING Applied Date: 05/17/2010 Issue Date: Receipt No.: R10 -00845 Payment Amount: $2,233.01 Initials: JEM Payment Date: 05/17/2010 09:00 AM User ID: 1165 Balance: $3,439.90 Payee: DGK ENTERPRISES INC. ROOF DOCTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12349 2,233.01 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 2,233.01 Total: $2,233.01 PAYMENT RECEIVED doc: Receiot -06 Printed: 05 -17 -2010 INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION to- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 .1io.»,, Project: sacs /2.7/40/1.91/ Type of Inspection: F,1✓ / Address: / -5-9a0 S / ilf e5),- Date Called: `) -4 - W /2024 L.0 sa 11. #4 p p.,.v #J -_,. Special Instructions: Date Wanted: / Z- / /— / 0 COZ p.m. Requester: ,,,De 'Apr ;74- 52-6,•;;C:-. e 7# Asie /r, j✓s92/ ' - - Phone No: .,2. .'.li 3— .36/ -73I Approved per applicable codes. Corrections -required prior to approval. . COMMENTS: / der el x.54to f;Ai — 4,41,4, I `) -4 - W /2024 L.0 sa 11. #4 p p.,.v #J -_,. ( Set 4., ,071or,." ,,> ,•;;C 14/. 6,1 ` a 5). y ,,,De 'Apr ;74- 52-6,•;;C:-. e 7# Asie /r, j✓s92/ ' - - Inspe 4 INSPECTION FEE REQ !REM j''rior.to next inspection. fee must b6 aid-at 6300 Southcenter B d:. Suite 100: CAllitS schedule reinspection: �•16•••• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ,s t- t EL-IT",-1 4 _ Type of Inspection: • F. I 1V t- (..f Address: CV2.6 ( &e) s-,-- Date Called: . Special Instructions: • el 4-04/0 /01 Date Wanted: it Requester: k4 Phone No:- I !! Approved per applicable codes. Corrections required prior to approval. COMMENTS: .ate it - — Inspector: Date: 1-7 REINSPECTION FEE REQUIRED: Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. teLMMietanr ..... • .e r:►rR.., l-...r: • ..,..q ■ _ •,• _ .'$'ate•• ••Wl,e+rt+c:4m INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / �� el :/ TypeIf Inst-Sio�n: �, ' Address: Date Called: \ rex, Si Special Instructions: C1 41 i 2,5-5-- c) / Date Wanted: ca .m - Z - I p.m. Requester: Phone No: _. �DG� —`�33 -44� 1 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: pN(--17A Al pi U .PA:( 6K- `rte p.i 0cee - I✓.) In c.r-\ 4,C_ 01 5---:J r- . %' A 6-0 A 1 1 IS Inspecto(: Date: -23-- /3 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit GAA Coo i 57 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ip .. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 2qs (-o J. Type of Inspection: �4of SLe,c .^61 Address: , ( ji Sr- Date Ile ,,._it JJ ('', Special Instructions: ,-- Date Wanted: a.m. - Z Z —1 c' p.m: Requester: Phone No: 7 3-ZCoi _'?310 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: P(Ar i 4-4 p u J4 �.}�� 3 3 C-60 eA Insp Date: _ .- 4 J El $60.00 REINSPECTION FEE REQUIRER. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Li INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �'• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 C -128 Pro"? F,6� 'IC Type,pf Insp tion;.L �...t/,, i 6 Add s' ' I+ 2A s- 1 vs-;- Date Iled: J s id 4/ , Special Instructions: ai/ ?I - (2 (X I (( AAA Date Wanted: pa.m. Requester: Phone No: 240 (el -q 34 -4(04r7 0 Approved per applicable codes. 0 Corrections required prior to approval. 7 COMMENTS: r'nra 1 (1-19p, 4 J A-P /\ I A e Ncr of-- ii t..r 1` 1s7P (7 :N ,D/PV1 °141( fl a Inspector: Date — 21 — /1) El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 b(3 -rte Projr:‘, 4a . ` u.\ Type f Inspec ii.on: r c i , J f Address: rt. S � 1-1A S - mod , to Called: ��._ltam. — LJ :1 k ��)1 (OA ASce �-- Special Instructions: O- . 1 l (a ` j t Date Wanted: r ��a.m_,, — P -m. Requester: —'` M er l.frk-S An rt ire r a a tA.) \c "-: Phone/r(3 — , 3 0 y/ I Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: i \ Msri At Alt 4)J AT 3 '0 r c i L k O A k tr— ?A c) F, ��._ltam. — LJ :1 k ��)1 (OA ASce F ; 1 .Pr►�`l JiT- . 1 Ap WtJ 4.0 AA, 1I'T 0n (1r S,JM 4 InAs .PQ.4A A-Ct. d [, S (4n _4( S ems. 9 a r f ef�, gr'- p`-1....e�:� ip r <TY'i1S rk. Ak3' N 61 /So lA y Be 'l —'` M er l.frk-S An rt ire r a a tA.) \c "-: Inspe or: Date: r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7 I INSPECTION RECORD I-Retain a copy with permit INSPECTION NO. G/t) D I o -l2$ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 •Proje! f 1�, 6 ``` Type I D �t1 L e "' �Aa�i Address ?N S. IsO+7L, 4_DateCaIIed: 6 Special Instructions: Date Wanted: — /3 m Requester: Phone No: 7,n(0 —q 30 --lY Yii Approved per applicable codes. El Corrections required prior to approval. COMMENTS: pa. r r1I44--k A-�° f-S J 6 Inspecl;6r: Date: [O ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: L____ INSPECTION RECORD etain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT (206)431 -3670 Project: 1 1-) 1.--, ^ Type of In pection 67 Ade s 2,6 y Date Called: Special Instructions: Date Wanted:/0 (t p.m. Requester: Phor1e No` ' / 36 —4 '/ 0 Approved per applicable codes. 1ebrrections required prior to approval. / COMMENTS: P ArN4A AgPw.rop,\ dk( `cam U 1 r f1(' J S • Inspect9f: Date: W ) $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 t O -i28 Project: a.as ( L.ITLr Type of Inspection: Pkc•- R..c.,>?oQr- (talc r ti ter (A) R i J Address: ,�4 s tel 0ST Date Called: Special I struct ions: ui P-.f r a- fir" T - fi ik i " `c Date Wanted: (.2 - LI- to rsT� Requester: Phone No: .253 --2-Cot -7210. 1 Approved per applicable codes. El Corrections required prior to approval. • COMMENTS: � (talc r ti ter (A) R i J -J ui P-.f r a- fir" T - fi ik i " `c to(-- 1:.„)‘ ric,i-K - 1 .. 1 Inspecto( /`k_) n Date: I ,4 ( ) ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .r...�..�.h.a5laftlx�s�ltlWASioagstxbihab 2 Johns Manville Building Owner Aldarra Management Building Name: Fidelity Building 5920 S 180th St Tukwila, WA 98188 Roofing Contractor ROOF DOCTOR (FORMERLY WELLS ENT.) 3465 MERTZ RD CARO, MI 48723 Commerciai%Indu strial Roofing Systems;; Material Warranty Membrane Type: JM PVC 15 Year Material Warranty Non - Transferable Material Warranty Number. 25148 Squares: 600 Material 1: JMPVC 50 Material 2: Material 3: Date of Completion: December 8,2010 AO-12,6 J1C MatLPLPf..f I MPr11r.1 y[ILPCPilC -rdra Pt�tC G gigarScyPLMMITM J jC1YOMPtPLILPrJ�rJ yr PrSJEI PJOTOJGjRIFFE i y£ CC.PC1ra1N_PcAFPL�f C3Pf. r PrPrJr Pr Pr�rlorJ�rJ81 J Je1?Jc 5JaJ I t JOHNS MANVILLE CORPORATION "Johns Manville" warrants to the original purchaser of its JM PVC Single Ply Membrane (the Membrane) that the Membrane is free from manufacturing defects and that the Membrane will not deteriorate due to weathering so that it becomes incapable of maintaining a watertight roofing system for a period of 15 years from the date of installation of the Membrane provided that the Membrane is properly installed, maintained and used in a manner consistent with JM requirements. TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, JOHNS MANVILLE DISCLAIMS ANY IMPLIED WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR LIMITS ANY SUCH WARRANTY TO THE EXPRESS WARRANTY STATED HEREIN. THE WARRANTY DESCRIBED HEREIN IS YOUR EXCLUSIVE WARRANTY FROM JOHNS MANVILLE AND REPRESENTS THE EXCLUSIVE REMEDY AVAILABLE TO ANY PURCHASER OF THE MEMBRANE. JOHNS MANVILLE MAKES NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND OTHER THAN THAT STATED HEREIN. THIS WARRANTY MAY BE MODIFIED ONLY BY INCLUDING THE MEMBRANE IN A JM PVC ROOFING SYSTEM GUARANTEE, PROPERLY ISSUED BY JOHNS MANVILLE OR SOME OTHER WRITTEN INSTRUMENT SIGNED BY AN AUTHORIZED JOHNS MANVILLE REPRESENTATIVE AND NO RETAILER, CONTRACTOR OR DISTRIBUTOR IS AUTHORIZED TO ALTER THIS WARRANTY. Extent of Johns Manville Liability During the 15 year period specified herein, if the membrane leaks and upon investigation is found to contain manufacturing defects which result in a leak or has prematurely deteriorated, you, as purchaser of the Membrane will, at the election of Johns Manville, receive a resupply of the Membrane or a credit to be applied towards the purchase of replacement materials, or receive a refund not to exceed the prorated limit calculated in the manner set forth below. Period of Warranty and Proration Formula First Year Warranty: During the one-year period immediately following the original and proper installation of the Membrane, if manufacturing defects or premature deterioration require the replacement of any portion of the Membrane, Johns Manville will resupply such material provided that the liability of Johns Manville for the replacement of such matenal shall not result in costs to Johns Manville which exceed the original cost of the Membrane Resupply Proration: After the initial years usage, defined in paragraph I hereof, if manufacturing defects or premature deterioration require the replacement of any portion of the membrane, the liability of Johns Manville for such replacement shall not exceed the original cost of the Membrane less the fractional use you had of that Membrane from the time of original and proper installation until failure as calculated by the proration formula described below RESUPPLY SHALL MEAN FURNISHING FREE OF CHARGE (F O.B. PLACE OF ORIGINAL PURCHASE) A NEW SHIPMENT OF THE MEMBRANE (IJNINSTALLED) IN AMOUNTS SUFFICIENT TO REPLACE THAT PORTION OF THE MEMBRANE FOUND TO BE IMPROPERLY PERFORMING. ALL LABOR AND SERVICE CHARGES WHICH MAY BE INCURRED WITH RESPECT TO EITHER THE ORIGINAL MEMBRANE OR THE REPLACEMENT MEMBRANE ARE TO BE AT YOUR EXPENSE AND NOT THE EXPENSE OF JOHNS MAN VILLE. Proration Formula: In calculating the Johns Manville liability, the cost of the original material to be resupplied will be reduced by the amount of usage you have received from the matenal prior to failure. The original purchase price of the material shall be reduced by U180 for every month of service the material provided after the date of original and proper installation. JOHNS MANVILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES SUCH AS DAMAGE TO THE STRUCTURE TO WHICH THE MEMBRANE IS AFFIXED OR ITS CONTENTS. NOR SHALL JOHNS MANVILLE BE LIABLE FOR ANY DAMAGES WHICH ARE BASED ON NEGLIGENCE, BREACH OF WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY OTHER THAN THE LIMITED LIABILITY SET FORTH ABOVE OR WHICH MAY BE ASSUMED UNDER A JM PVC ROOFING SYSTEM GUARANTEE. INCIDENTAL AND CONSEQUENTIAL DAMAGES SHALL NOT BE RECOVERABLE EVEN IF THE RESUPPLY REMEDY PROVIDED FOR HEREIN FAILS OF ITS PURPOSE. 0 5 5 5 5 1CPEPrJrldCPrPLPtPPcPCPPEPrJ�rJ arlaLPrPt PC. fr31' yLPcPtPrJcPEPCPEPrJyCPcPLPLPLPLPrJc.roCPEPCPEP CPCPEPcPLPCPr1cPLlr Ir11cPrPcPrPEPEPCPcPCPCPrPr�E (yEPEPCPtJME�`JCPCJtti" r PcJL;fiycJa��LPclai a a EXCLUSIONS JOHNS MANVILLE AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES TO THE BUILDING STRUCTURE (UPON WHICH THE MEMBRANE IS AFFIXED) OR ITS CONTENTS, LOSS OF TIME OR PROFITS OR ANY INCONVIENIENCE, JOHNS MANVILLE AND ITS AFFILIATES SHALL NOT BE LIABLE FOR ANY DAMAGES WHICH ARE BASED UPON NEGLIGENCE, BREACH OF WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY OF LIABILITY OTHER THAN THE EXCLUSIVE LIMITED LIABILITY SET FORTH IN THIS LIMITED WARRANTY, INCIDENTAL AND CONSEQUENTIAL DAMAGES SHALL NOT BE RECOVERABLE EVEN IF THE REMEDIES OR ACTIONS PROVIDED HEREIN FAIL THEIR PURPOSE. Johns Manville shall not be liable for any damages to the roof insulation, roof decks or any base over which the Membrane is applied, or for the leaks, damages or inquiries attributabie to any of the following (or any combination thereof): (1.) Workmanship. including faulty or improper application of the Membrane. Faulty or improper application not done in accordance with Johns Manville published specifications and application recommendations in effect at the time of the application of the Membrane. (2.) Deterioration to areas of the roof or areas of base fleshings and application recommendations in effect at the time of the application of the membrane. (3.) Any changes in the building usage unless approved in advance in writing by Johns Manville. (4.) Any maintenance. repairs. alterations or new installations to the Membrane or the base flashing that take place after the completion of the original installation, unless carried out in a manner which is acceptable and approved in advanced in writing by Johns Manville. (5.) Deterioration of the membrane caused by moisture infiltration or condensation that occurs in around or under the roof deck, coping walls, or unbonded fleshings. (6.) Damage caused by non -Johns Manville materials, including but not limited to, fleshings, whether of bituminous or other materials, or expansion joints. metal work, pitch or penetration pans, walkways, or any roof top units or equipment. (7.) Natural disasters including, but not limited to, of lightning, floods, strong gales, windstorms, seismic disturbances, hurricanes, tornadoes. hailstorms, or impact of foreign objects or other violent storms or casualty. (8.` Acts of war, civil insurrection, riot. or vandalism. (9.) Damage resulting from any form of roof top traffic, misuse, abuse or negligence. (10.) Damage resulting from exposure to chemicals including, but not limited to, aliphatic or aromatic solvents, chlorinated hydrocarbons, turpentine, organic or inorganic polar materials. or oils. (11.) Damage resulting from vermin. (12.) Building expansion or additions or reductions; settling, distortion, failure or cracking of the roof deck, walls or foundation of the building. (13.) Structural defects or failures in the building to which the Membrane is applied. (14.) Leaks or damages due to failure to follow the Johns Manville recommended maintenance program. (15.) Splitting, cracking, blistering, delamination of the membrane due to underlying materials (e.g. base sheets, insulation or structural decks). (16.) Applications over buildings with high internal humidity. freezer buildings, or buildings used for cold storage. WARRANTY TRANSFER This limited warranty shall accrue and inure only to the first purchaser or owner of the Membrane and shall not be assigned, sold or transferred in any manner whatsoever. Any assignment, sale or transfer of the building to which the membrane is applied shall void all warranties contained herein or hereunder. Maintenance Program In owner to continue the coverage of this Guarantee the following maintenance program must be implemented. There are a number of items not covered by this Guarantee that are the responsibility of the owner. In order to ensure that your new roof wit continue to perform its function, you must examine and maintain these items on a regular basis: • Maintain a file for your records on this roof, including this Guarantee, invoices, and subsequent logs of all inspections performed and repairs that are made to the roof. Inspect your roof at least semiannually, This is best done in the Spring, after the roof has been exposed to the harsh winter conditions, and. in the Fall after a long hot summer. It is also a good idea to examine the roof for damage after severe weather conditions such as hailstorms. heavy rains, high winds, etc. • Since these types of roofs typically have a low slope they are easily examined. However, care must be taken to prevent falling accidents. • Ensure that all drainage areas, gutters, scuppers and drains are cleaned on a regular basis. This will allow for proper water run -off and avoid overloading the structure with ponding water. Positive drainage is essential. • Remove any debris such as leaves, small branches. dirt, rocks, etc. that have accumulated. • Examine a!! metal lashings and valleys for rust and damage that may have been caused by wind or traffic on the roof, and make certa:n they are we.; attached and sealed. Any damaged, loose, or poorly sealed materials must be repaired by an Approved Roofing Contractor • Examine the areas that abut the roof. Damaged masonry. poorly mounted counter flashing, loose caulking, had mortar joints, and any ioose stone or tile coping can appear to be a membrane leak. Have these items repaired if found to be defective. • Examine the edges of the roof. Wind damage often occurs in these areas. Materials that have been lifted by the wind need to be corrected by an Approved Roofing Contractor. • Examine any roof top equipment such as air conditioners, evaporative coolers, antennas, etc. Make certain they do not move excessively or cause a roof problem by leaking materials onto the roof. • Check the building exterior for settlement or movement. Structural movement can cause cracks and other problems which in turn may lead to leaks in your roofing system. • Examine prorective coatings: any cracked. flaking, or blistered areas must be recoated. Protecting your investmert: • Avoid unnecessary roof top traffic. • if you allow equipment servicemen to go onto the roof, advise them to be careful. Dropped tools, heavy equipment. etc can damage the membrane. Log all such trips to the roof. • Do not allow service personnel to make penetrations into the roof; these are to be made only by an Approved Roofing Contractor. At the Terms and conditions of this Guarantee shall be construed under the internal law of the state of Colorado without regard to its conflicts of law principles. Invalidity or unenforceability of any provisions herein shall not affect the validity or enforceability of any other •provision which shall remain in full force and effect. Tnis form is not to be copied or reproduced in any manner. This Warranty is valid only in the United States of America and Mexico for USA owned buildings. This Johns Manville iimited warranty applies to products sold on or after July 1 2003 supersedes all previously published warranties. Guarantee Services Unit Johns Man: tile. Guarantee Services Unit, 10100 West Ute Ave., Littleton, CO 80127 (shipping address) Johns Manville, Guarantee Services Unit, P.0. Box 625005, Littleton, CO 80162 -5005 (mailing address) Guarantee Services Regional Phone Numbers Eastern Northern 800 - 345 -9603 800 -231 -1064 www.jn.con, E -mail: gsu @jm com SouthwesUWest 800 - 922 -5922 MOLITION VICINITY MAP .1 11 r •?, 1, 1111111 A I- IAZARDOUS MATERIALS r If 1 T A I I I. IA1.3 INCLUDING BUT NOT LIMITED nI , !•.t II" ANY EXIST). 1• r A t '1 1.1-111 ro REMOVE HAZARDOUS • 1 1 At,' AII•' A(:,ENCY. NO DEMOLTION IS TO 11 r 1 1 11 HA I I -I ,( II,* I- IAZARDOUS MATERIALS 1 • r° I I '. 1.1 I I • I VI I) A PERMIT FROM THE PUGET 11 a ,it '.•1, 11 ; 4 : ,000 PSF FOR FOUNDATION r 1 1 r•.1 1 .,A1.11-t!, 4 MOORE. ,tiP'A' I I 11-1F SOILS AFTER DEMOLITION AT 11, I I I r',( III ", I �l A LICENSED SOILS ENGINEER 0'1111 1111 I Ili r *' TUKWILA BUILDING DEPARTMENT. +I p 1.1 1 'II-1. rINDINGS TO TI-IE ARCHITECT AND 111• ; , 'I U 1 -'1.1I : 1'00TINGS. F LE COPY Perms Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an • • nditions is acknowledged: By Date: City Of Tukwila BUILDING DIVISION REVISIONS No chanties shall be made to the scope of work without prior approval of G Tukwila Biriiriinri D'virinn 0 i ivv 1 C Revisions will require a new plan submittal- and may include additional plan review fees. T U MINKLER BLVD W VALLEY. HWY INTERURBAN TR SW 43rd ST VICINITY MAP NOT TO SCALE OAKESDALE AVE SW CODE VIEWED COMPLIANCE WW APP fVED fiAl 2 8 1010 City of ft kwj L 444' BUI'.DING DIVISION I IIPJ l 11; CITY OF MAY 171010 g4 PERMIT CENTER PlO19i EGRESS LIGHTING NOTES UNDER NORMAL POWER, THE ILLUMINATION LEVEL 51-IALL BE NOT LESS TI-IAN 1 rnt?T- CANDLE AT EVERY POINT IN TINE MEANS OF EGRESS PAIN_ 1 it ri1 11 DENS -DECK® ROOF BOARD DENS- 1D1ECK®PRIME ROOF BOARD SUSTAINABLE MATERIALS DATA SHEET See MSDS for additional Information) GP GYPSUM SUSTAINABLE MATERIALS DATA SHEET Page 1 of 2 Effective Date: 3/15/2002 Super. cedes Date: 3/11/2002 \----- REVIEVVE�D F CODE c ��+vEa APP �Nt 2 8 2010 City of Tuk� BUILDING 1 ' LSECTION 1. PRODUCT & COMPANY IDENTIFICATION PRODUCT NAME: Dens Dock Roof Board. Compliance with the performance based qualities of this product based on material composition is obtained by referencing ASTM C 1177. PRODUCT USE Glass Mat Faced, Moisture Resistant, High Compressive Strength & Modlosfof+" ' "'r ACTURED BY: Rupture Gypsum Roof Board Available with a Primed Positive Si Surface. Georgia•PaCiftc Canada Inc. °®� G-P Gypsum Corporation A wholly owned subsidiary of Oeorgia- Pacific Corporation 133 Peachtree Street, N.E. Atlanta, GA, 30303 (770) 987 -5190 (Technical Information) (404) 652 -5119 (MSDS Recuxst) A wholly owned subsidiary of Georgia- Pacific Coporation Allanburg Road Tborold, Ontario L2V 3ZB, Canada (770) 987 -5190 (Technical Information) (404) 652-5119 (MSDS Request) CTION 2. RECYCLED CONTENT (Comports With Federal Trade Commission Guides For The Use Of Q tabrunental Marketing Claims, 16 C.F.R. 260.7(e). (Percentages are by Weight and Vary by Location) CI-EEO Recycled Content Credit 4.1) Manufacturing Location Total Recycled Content Post Industrial Recycled Content Post Consumer Recycled Content Acme, TX 5.70% 5.45% 0.25% Brunswick, GA 10.88% 10.63% 0.25% Camden, NJ 7.81% 7.56% 0.25% Las Vegas, NV 8.89% 7.60% 1.29% Sweetwater. TX 6.67% 6.42% 0.25% Tacoma, WA' 13.96% 8.26% 5.70% Plants are scheduled to be added going forwarded. Please call the technical information line to determine if a closer plant has been brought on-line. "Tacoma plant will be 100% recycled by the end of 2002 with extracted material coming from Centralia, WA.. [SECTI0N 3. LOCAUREGIONAL MATERIALS ('LEER LocalfRegional Materials Credits 5.1 & 5.2) 1 Please determine the distance in statute miles to your project site from the closest Dens- Shield manufacturing location listed in SECTION 2. Manufacturing Location Extraction Location Acme, TX Acme, TX Brunswick, GA Port Hawksbury, Nova Scotia Las Vegas. NV Las Vegas, NV Cont'd CITYO�LA MAY 17 ZULU PERMIT CENTER Sweetwater, TX Sweetwater, TX Tacoma, WA Comsa, Mexico Camden, NJ Port Hawksbury, Nova Scotia You may use the following web -site to determine the distance to your job -site (not a GP web- site): httpi/www.indomin/digin c t SECTION 4. PRODUCT BLOCKS THE INTRODUCTION, DEVELOPMENT, & SPREAD OF INDOOR CONTAMINANTS (LEED Innovation in Design Process Credit) Inorganic, "0 -Mold" product that passes the ASTM D 3273 -94 Mold Test (4 -weeks of testing with no mold growth) that may qualify for a LEED Innovation Crcdit based upon the environmental mitigation. of mold and mildew hazards related to Indoor Air Quality (IAQ). Also acts as a solvent barrier. Additionally, in fire -rated assemblies, product is a 0- smoke, 0 -flame product according to ASTM E 84. The "Construction iAQ Management Plan" (Credit 3) uses the "EPA Protocol for Environmental Requirements, Baseline iAQ and Materials for Research Triangle Park Campus, Section 01445" (www.epa.govirtp /new- bldefenvironmepttd /s 0) 445.htmj as one of it's reference standards and incorporates a test for Mold & Mildew thusly: "Compliance Indoor air quality shall conform to the following standards and limits:... Airborne Mold and Mildew: Simultaneous indoor and outdoor readings. This Specification section was a part of the construction documents for the EPA's Research & Administration Facility at Research Triangle Park. The section addresses baseline indoor air quality testing and materials testing." One of the five areas covered to protect against IAQ problems is through "Source Control" of materials that could be a potential hindrance to passing the testing phase of the aforementioned IAQ LEED Reference Standard. Specifying products that pass the ASTM D 3273 -94 Mold Test could provide an effective method for protecting IAQ, SECTION 5 EXCEPTIONAL DURABILITY & LOW MAINTENANCE REQUIREMENT (*LEED Construction Waste Management 2.1) Because Dens-Deck has a maximum compressive strength of 943 PSI and a modulus of rupture of 1,276 PSI, the roof membrane and fire rating of the roof assembly is protected when Dens Deck is used as a cover board. The product has a very low wicking quality which localizes water infiltration and thc product will retain its stratgth when left to dry sufficiaitly. Dens Deck will achieve wind uplift ratings of up to FMRC 1 -180. (see specific technical documents for further details by visiting www,kn,com /tarnsutn or by calling the technical information line) SECTION 6 REDUCES THE IMPACT OF NEW CONSTRUCTION (*LEED Construction IAQ IManagement Credit 3,1) ISECTION 7. DOES NOT RELEASE SIGNIFICANT POLLUTANTS INTO THE BUILDING ( "LEED Construction IAQ Management Credit 3.1) No reportable VOCs in the finished product as defined by OSHA at 29 CFR 1910.1048. (see MSDS sheet for hazardous ingredients by visiting wwwia,ccnm'gvpsum or by calling thc technical information line) No reportable VOCs in thc finished product as defined by OSHA at 29 CFR 1910.1048. (see MSDS sheet for hazardous ingredients by visiting www.gp.csm,/fcvnsum or by calling the technical information line) "All LEED Rating Point References Are Suggested Applications Of Dens Glass To The LEED Rating System. LEED Applicants Should Use Their Own Objective Determinations Of Product Attributes For LEER Certification Purposes. SECT ION FIVE - HEALTH HAZARD PRIMARY ROUTES OF EXPOSURE SIGNS AND SYMPTOMS OF OVEREXPOSURE: ACUTE CHRONIC AGGRATATED MEDICAL CONDITIONS EMERGENCY AND FIRST AID PROCEDURES: INHALATION EYES SION INGESTION OTHER INHALATION. STAN CONTACT, (ONLY FROM DUST GENERATED DURING FABRICATION) TEMPORARY MECHANICAL IRRITATION OF EYES. NOSE. THROAT, LUNGS AND POSSIBLY SKIN POSSIBLE ALLERGIC REACTION OF RESPIRATORY ILLNESS OR DERMATITIS COULD BE AFFECTED SEE SECTION NINE BELOW REMOVE TO FRESH All FLUSH WITH WATER FOR 15 MINUTES OR UNTIL IRRITATION CEASES WASH WITH SOAP AND WATER N/A 111I5 PRODUCT IS NOT EXPECTED TO PRESENT HEALTH HAZARDS UNDER NORMAL USE SECTI ON SIX • REACTIVITY DATA STABLE CONDITIONS TO MID INCOMPATIBILITIES HAZARDOUS DECOMPOSITION PRODUCTS X UNSTABLENATARDOUS POLYMERIZATION WILL BURN IF EXPOSED TO FIRE OR SUFFKIENT NEAT INTENSITY NONE KNOWN LIKE WOOD AND OTHER ORGANIC MATERIALS, CAN RELEASE TOXIC SMOKE 11 IGNITED SECTION SEVEN - SPILL AND LEAK PROCEDURES ACTION TO BE TAKEN IF RELEASED OR SPILLED NORMAL HOUSEKEEPING DISPOSAL METHOD IN AC(ORDANa WITH FEDEBAL, STATE, AND LOCAL REGULATIONS SECTION EIGHT - REACTIVITY DATA VENTILATION RESPIRATORY PROTECTION PROTECTIVE CLOTHING EYE PROTECTION NOT NECESSARY UNLESS FABRICATING, IN WINCH CASE USE SUFFICIENT VENTILATION TO KEEP DUST BELOW SMG/N3 (RESPIRABLE NUISANCE DUST) DUST MASK DURING FABRICATION IF NECESSARY (NIOSN CERTIFIED ONLY) NOT NECESSARY AS NECESSARY SECTION NINE - .SPECIAL PRECAUTIONS PERSONS WHO DEVELOP IRRITATION: RESPIRATORY PROBLEMS; RESPIRATORY PROBLEMS: OR PUFFINESS AROUND THE EYES SHOULD BE EXAMINED BY A PHYSICIAN AS SOON AS POSSIBLE. HUN+ E R Energy Smart Polyiso 888 - 746 -1114 APPnowEo 5 FRANNUN STREF1 PORTLAND, ME 04101 Ta: B88745 -1114 FAX: 8/M75.17119 PUNTS: KINGSTON, NY AND CHICAGO, IL rnv,.n4 n....a. boo.es..y, MATERIAL SAFETY DATA SHEET NFPA RATINGS 4 = EXTREME 3 =NIGH 2 = MODERATE I = SIGHT 0 = NEGLIGIBLE SECTION ONE - IDENTIFICATION HUNTER PANELS I5 FRANKLIN STREET PORTLAND, ME TRADE NAME AND SYNONYM 888.146.1114 OR 201.10678 EFFECTIVE DATE: 01/01/03 HUNTER PANELS "H" SHIELD/TAPERED MANUFACTURED USING NEX6EN CHEMISTRYT" I INGREDIENTS SECTION TWO - CAS NUMBER (% )'o INGREDIENTS OSHA PEL ACGIH TWA COMMENTS 01 POLYISOCTANURATE FOAM NONE <60 NONE NONE — 02 PROPRIETARY HYDROCARBONS PENTANE 109 -66-0 <10 600 600 PPM ISOPENTANE 704.4 <10 600 600 PPM CYCLOPENTANE 281-92-3 <10 600 600 PPM 03 RBROIIS GLASS 69997 -11 -3 <4 NONE ID MG/M3 04 CELLULOSE NONE <26 NONE 10 IIG/M3 AO exposure Omits ere eight hour time weighted averages unless otherwise noted Ostia PEL and ACGIN TLV's are current values SECTION THREE - PHYSICAL DATA BOILING POINT VAPOR PRESSURE VAPOR DENSITY SOLUBILITY NIA NIA 11/A N/A SPEOFIC GRAVITY PERCENT VOLATILES EVAPORATION RATE APPEARANCE AND ODOR NOMINAL 2.0 CBS/CUBIC FT N/A WA WHITE OR CREAN COLORED FOAM ONE WITH CELLULOSE GLASS FIBER FACINGS, 000RLESS SECTION FOUR - FIRE & EXPLOSION DATA FLASH PWNT (METHOD) FLAMMABLE LIMITS EXTINGUISHING MEDIA SPEIAL FIRE FIGHTING PROCEDURES UNUSUAL FIRE AND EXPLOSION HAZARDS STORAGE MATERIAL 888 - 746 - 1114 • N/A LEL N/A VEL NIA CO,, DRY CHEMICALS, FOAM. WATER. FOG SELF- CONTANIED PLATTING APPARATUS NONE KNOWN CLASS 2 COMMODITY (UFC) WWW.H U NTERPAN ELS.COM H- 'SHIE'LD CODES AND COMPLIANCES FEDERAL SPC•CWICATIONS • ASTM C1289 -05a• 1* II. Class 1, Grade 2 (20 psi), Grade 3 (25 psi) • National Building Code (1998) SecPon 2603 Building Officials and Code Administration International. Inc. NOTE: Please be aware the Federal Spedficae on N1H- 19721GEN has been replaced UNDERWRITERS LABORATORIES, INC. - Component of Class A Roof Systems (UL 790) • Hourly Rated P series roof assemblies (UI. 263 foam core only) P 225, 230. 232, 259. 508. 510. 314, 519, 701, 713, 71-7.718.719. 720.722,723. 724. 727, 728. 729. 730. 732, 734. 735, 739. 801. 814, 81.S. 818. 819. 823, 824, 826. 827, 828. 832. • Insulated metal deck assemblies - UL 1256 (nos. 120. 123) • H- Shield classified by ULC • R18846 FACTORY MUTUAL RESEARCH • FM 4450, FM 4470 (Foam Core Only) FM Class 1 approval for steel roof deck constructions, Class 1 Fire and 1 -60 and 1 -90 windstorm classification (FM 4450). (Subject to die concenoni or eppmuntescribed In Me win, Factory Waal Approval Guido and Suppbmenb) FLORIDA BUDDING CODE APPROVAL FL# 12% MIAMI -DADE BUILDING CODE COMPUANCE NOA NO: 04- 1018.01 WARNINGS AIND 1'IMITATIONS Insulation must be protected from open flame and kept dry at all times. Install only as much Insulation as can be covered the same day by completed roof covering material. Hunter Panels will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the Job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Hunter Panels for more spedfic details. or refer to PIMA Technical Bulletin No. 109: Storage 8 Handling Recommendations for Polylso Roof Insulation. ti PIhQualuyMark- Immo TYPICAL PHYS POLY! ICAL PROPERTY DATA CHART SO FOAM CORE ONLY PROPERTY Compressive Strength Dimensional Stability Moisture Vapor Transmission Water Absorption Flame Spread (foam core) Service Temperature TEST METHOD VALUE ASTM D 1621 20 psi' minimum ASTAA 1289 -05e (13BkPa, Grade 2) ASTM 0 2126 2 %.1inear change (7 days) Also available in 25 ASTM E 96 < 1 perm ((57.5ng /(Pa °s•m')) ASTM C 209 < 1% volume ASTM E 84 < 50 -1004 to 250' F ( -73 °C to 122'C) psi minimum, Grade 3 PRODUCTS BY HUNTER. • N- Shield -NB /Olio nnN%n TO 0R,tvtfn ,,7R,tNi) RtlAr • 8-Shield-Mt mini) arwn,;n m anon I1R1 R►aulD • H- Shield•F Pcxrrsu ra)NDEn'n Rm. • II-Shield-CB POU•I-m° RDNDEII TO f 1w1 a? timss F k-ER • 14• Shield •AGF POI.nc) &:worm )a ncir Fi ER • H- Shield -DD nvxlsn I Wrfp TO owsnFCN • N- Shield-DDP Peons,, Iauvr. tl) TO PRIMED DENSIVO: • Tapered H- Shield 1:1rrRr;D tars() • Tapered H- Shield -WF 1Ai aw r xr sn RONI Er) In wuon r•IRr.RRQ•len • Tapered H- Shield-CG TAMED rot i ci BONDED TO t:oAiw dims Facia • Cool -Pent t+EN IATfI) NAn &ASE INc1.44T1(W INNEI. - Cool -Vent II VENTILATE() VU,xk%r INQI1.ATION rtNEI. HUN±E R Energy Smart Polyi.so 888 - 746 -1114 15 FRA1011.0. STRHit, PORTLA11D, ME 04101 • Fart: 877 -77S -1769 MANUFACTURING FACILITIES: KINGSTON, NY FRANKER, PARK, IL LUE CIn. FL TERRELL, TX Toone, 111 SMminao, PA !AI H- SHIELD Fr./T POLY /50 PRODUCT DESCRIPTION H- Shield Is a rigid roof Insulation panel composed of a dosed cef polylsocyanurate foam core bonded on each side to fiber reinforced facers. FLUMES AND Worts Manufactured with NexGen Chemistry? - Zero ODP. CFC Free. EPA Compliant. • Approved for direct application to sted decs. • Approved under all major roof covering systems — BUR. Modlfled and Single Ply. Patio CHARACTERISTICS • Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x 2440min) panels In thickness of 1"(25mm) to 4.0" (102mm) • Available in two grades of compressive strengths per ASTM C1289-05a. Type II, Class 1. Grade 2 (20 pd). Grade 3 (25 psi). Ammon • Constructions requiring FM Class 1 and UL Class A raitngs • Singk.Ply Roof Systems (Ballasted. Medianlcally Actadied. Fully Adhered) • Modified Bitumen Systems • Built -Up Roofing: Asphalt and Coal Tar H;- SHIELD THERMAL VALUES THICKNESS (INCHES) (MM) 1.00" 25 1.50" 38 1.60" 41 1.70 " 43 LTTR FLUTE R VALUE* SPANABRATY 6.00 2 5/8" 9.00 4 3/8" 9.60 4 3/8' 10.30 4 3/8" 1.80' 46 10.90 4 3/8' 2.00" 51 12.10 4 3/8' 2.50" 64 15.30 4 3/8" 2.70" 69 16.60 4 3/8' 3.00" 76 18.50 4 3/8" 3.10" 79 19.10 4 3/8" 3.30" 84 20.40 4 3/8" 3.50" 89 21.70 4 3/8" 3.60" 91 22.40 .___.. 4 3/8" 3.70" 94 4.00 102 23.00 4 3/8" 25.00 4 3/8" 'Long Term Thermal Resistance Foam Core Vahan are based on ASTM C1289415a and CAI WLC S770 which provides for a 15-year time weighted average. AO PIMA members have adopted this advanced standard to R -value measurement as of 1/1103. NEGEN C H E M T 5 T R Y INSTALLATION BURT UP, COAL TAR AND MODIFIED BmJMEN SYSTEMS Each H- Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Maximum 4'x4' (1220mm x 1220mm) panels of H- Shield may be adhered to a prepared concrete deck with a full mopping of hot steep asphalt. Application by cold adhesion also approved. Butt edges and stagger Joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. SINGLE PLY SYSTEMS BRASTED SINGLE PLY SmSTENS Each H- Shield panel is loosely laid an the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. NEO AIMCAW ATm hED Swag Pic Srswn Each H- Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Butt edges and stagger Joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Fwii ADHERED SINGLE Plc Each H- Shield panel must be secured to the roof deck with Factory Mutual approved fasteners and plates (appropriate to the deck type). Maximum 4'x4'(1220mm x 12 20mm) panels of H- Shield may be adhered to a prepared concrete deck with a full mopping of hot steep asphalt. Application by cold adhesion also approved. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. 888 -746 -1114 • WWW.HUNTERPANELS.COM Georgia Pacific is DensDeck@ Roof Board Technical Service Hotline 1.800.225.6119 or www demsdeck.com Technical Data Flame spread 0, smoke developed 0. when acted in accordance with ASTM E 84 or CAN/1.11,C-S102. Nonce nbursible when tested in accordance with ASTM E 136. DcnsOeck Fireguard: UL Classified when tested in accordance with AS'I'M E 119. 5/8' DensDeck can replace any generic Type )( (111/sum board n any root assembly in the UI. Foe Resistance Directory under the prefix 'r. 1/4' DensDeck has been tested by Factory Mutual for 60 psi and 911 psi wind uplift for BUR, EPOM. thermoplastics and modified bitumen roof systems. Higher wind uplift ratings have been arhieved by rfrmteratrs merrlbrane manufacturers using DensDeck in their FMRC- applwad construction designs. Miami -Dade County, Florida NBA 07-0124.02 Thickness, nominal Width. standard Length. standard Weight. Ibs jse. ft.. nominal - - - Surfacing Flexural Strength' parallel, Ibs. min. Flute Spanabfiiry -- ___ Permeancet, Perms "H' Value' Linear Variation with Change in Temp., in/in'F lanar arriauon with Change in Moisture. in /in Water Absorption'. % max Compressive Strength. psi nominal 1/4•41/15. 4' t 1/8" 4' and 8' i 1/.4" Glass mat µ 1-40 2 -5/B' 50 — — .2B Vg10r- %RH 6.25%104 10.0 500 -900 Surface Water Absorptions, grams, nominal Flame Spread. Smake Oevtalpped (ASTM E 84) Eire Classification 2.5 1/2' ± 1/3T 4' t 1/8` - -- ' a'ana8'si%4' -•- 1.95 Glass mat 60 _j1/9' is 1/32' 4' s 1/8' 4'_and 8' t 1 /4" -- '- Glass mat 100 8' E8.501fr 6.25x10" ' 10.0 X10 -6O- 2.5 0/0 UL 1256. ULCS-126 UL Classified 'P' assemblies ULC Dawdled 13- curdles dies ULC 5-101 Class A NL 790), ULC 5-107 (;11 T Mold resistant 35 .56 8.510 -5 6.25x10-" 10.0 500 - 900 2.5 _-nom UI-1256. ULC S- UI. Class A (Lit 7901 ULC S -107 Q tan azd - - - - -- -Mold Resistance pt Ali la C) 3x736 — FM Approvals' Bending Radius MI 126 Ul 1256, UI_C S -128 UL Class A (UL 7901 ULC 5.107 01177 - Mid resistant 60 and 90 psf uplift/ FM Class 1 90 as an overlaymentl U1'/1 Mold resistant - FM 1-60, 1. 90,1 -135 • I. Tested InsamorsaiwrMASTMC /71 7. Taxrod h any/dance with AVM( klf MOO itt cwtc. lwdanfY fur 7/2' end *an 3. Tasted InnnmrpwandwdaASTMF •96ldar cup merMd e. awed in accordance WO A,SIM C srAOrm mmr rneraxl Georgia-Pacific Gypsum SALES INFORMAT10N ANO meet PLACEMENT U.S.A. Midwest: 0.1008784748 West: 1-000-824.102N South veneat7 -?386 Northeast: 1.800+947415/ CANADA Cando Toll Free: 1- 1D8- 014573 Ouabec toe Frey 1- 800`381-0165 6emgie -Pacific GYesum Technical Hotline U.S.A. and Canada 1- 50O•l158119 Mon. -Fri.. 8 a.m.. 5 p.m. ET T8lwtamARKS The GEORGIA-M(21C boo and al trademarks are oenrd br er'Immo to 60oreirePealc Gypsum U.C. UPDATES ADO 1INIBit FNFOPMAT10N The informedan In thh dastuncet may charge without notice. Vise ow Web site b updates end alrrartl edoreWhpt 20111 GCmala•Patific Gvpaan U.L. A8 FOPS tosamd. Printed in USA. Rest 07/07 IA. tern /10151& FM 1.60.1- 90.1.180 .5 ASPIC t In nrkdnwmt. A Ewan retreat as manufactured In nttmennce *Oh ASTa./ 0 3771 7 Hiphm wind upanmmnps Afro been atieven by mmarratt monusvtc mandathamntaw DennDeck. Otuvel eck Prhhm ornoastaat• Rraarranr root Dratrds in their FMytopn,MOnSqu tide &okras. UNMAN 00 PEMEDIE9 AND DAMAGES Unless othantiee Dated D our wretirt laMMCO warfarin for side produn out cob eadelry tin soy Product chasm shall be looped In relmborsernem of the test M repair or roatacernent of the affected product, up to a nmeesaun amount attwotimes the *WI pun:lune Dace for the affected product WC Wdll not be remand a ruder any orcumwocus for Ian pmrtt. demo m o structure ar Its spmoma. a initnucl, incidental. special or crosegnonvul rlemaocy. Claims shag Ise deemed waited N they ire not 'Joined to us in wiling write ran days arm discovery. SAFETY CAUTION: This paw contains tibet5lass. Fibas and AID try be !alums hoes 1043 terries during 'swami !madam end may main in akkL eto aa1 resonators irritation. Avoid baahlrg dug end (Anon wan ma aka old awe Fallow these mantled wodrpadm° wear a bettrinalc ton0- skated shin aryl Prop trams. protective gl0080 and eye pylon rwpgles or PAN, plans with side ddelda4 W o cost mask when milk Mdhianel prtxonkp may bu ncedod Wien wry dusty. Oa not the a watt saw, Fm Material Safety Data Sheer ro eedltlerot ro brmmien. tall 1.P00- 2254110 m visit our Web she. May. 14. 2010 10:53AM Intermountain Seattle a LI I Johns Manville ENRGY 3m No. 0132 P. 2 Description ENRGY 3 is a rigid roof insulation board composed of a closed cell poiyisocyanurate foam core bonded in the manufacturing process to universal fiber glass reinforced facers. ENRGY 3 utilizes an environmentally compliant blowing agent con- taining pentane hydrocarbon to enhance the thermal performance of the foam insulation. This hydrocarbon has zero ozone depletion potential and conforms to the Montreal Protocol established in 1987 ENRGY 3 meats the physical property requirements of ASTM C 1289, Type II, Class 1, Grade 2 end CANNLC S704, Type 2, C1894 2. ENRGY 3 specialty products are also available es tapered panels, precut miters and precut crickets. Use ENRGY 3 provides high thermal insulation value over metal. Mailable and non- nailable roof decks In built -up, modified bitumen and single ply membrane roofing systems. It may be applied using bet bitumen, cold adhesives or mechanical fasteners. The universal facer on both the top and bottom provides a suitable surface for mechanical attachment to a structural deck es well es a suitable surface to apply hot asphalt or cold adhesives. ENRGY 3 is rated in FM Globel°fire- and wind- resistent systems for BUR, modified bitumen and single ply systems in specific constructions. It has been classified by UL° as an approved roof laudation in many Class A roof constructions and Roof/Ceiling hourly lire -rated assemblies, end Is classified by Underwriters Laboratories of Canada. JM supports NRCA Bulletin 09 in recommending that a cover board of Fesco° Board or 65' (1.27 cm) Retro -fit" Board be installed over foam Insulations In hot bituminous membrane systems. Energy and the Environment LIED Recycled Content Pre - Consumer: Post - Consumer: See chart below See chart below Producing Locations Bremen, IN Fernley. NV Jacksonville, R. Cornwall, ONT Hazleton, PA Typical Physical Properties Values Test Method Water Absorption ........... .......-.<1.516 max._......_ ASTM C 209 Dimensional Stablbty Change-.<216 _ ....._ ....ASTM 0 2126 Compression Resistance' 10% Consolidation-psi (kPal_20 (138) min..._...._.._.ASTM D 1621 Moisture Vapor Permeance <1 perm ................... ASTM E 98 57.5 ng/(Po•s•m') Service Temperature •100 °F - 2501 (•73'C • 121•C) Tensile Strength -psi (kPa1._...._730 (35) nom ..... _..ASTM 01623 • aao avaaable in 25 per (17Z keel. Refer to the Material Safety Data Sheets and product labels prior to using this product. Advantages • IGgh thermal efficiency • Universal facer that is compatible with BUR, modified bitumen and single ply membrane systems • Complies with EPA, CEPA and Montreal Protocol requirements • Meets Clean Air Act Amendments of 1990 • Third -party certification with the PIMA Quality Mark` for Long -Term Thermal Resistance (LTTR) values • Potential LEED points Sizes ENRGY 3 is available in 4' x 4' (1.22 m x 1.22 m) or 4' x 8' 11.22 m x 2.44 m) boards (other sizes available by special request) and in thick- nesses of 10 (2.54 cm) to 4.0'110.18 cm). Some sizes are special order with inoumum order quantities. Contact your JM sales representative for details. For Use over Metal Decks The minimum thicknesses of ENRGY 3 and ISO 3 insulation over metal decks are as follows: Width of Up to 2%' Up to 3W Up to 4W Rlb Opening (6.67 cm) (8.67 cm) (11.11 cm) Thickness 1.0` (2.54 cm) 1.2 (3.05 cm) 1.7 (3.30 cm) of Insulation (Minimum) Product Data Standard thicknesses fermi MB* R- Valee' Recycled Content" Pre•Wnsemer Past-Cetuuner Total (IQ (esn (hr'f"•RIB1U 1%) 19U 1.0 1.5 1.7 2.0 2.9 2.5 2.8 30 9.1 3.3 4.0 25 6.0 38 9.0 43 10.3 51 12.1 58 14.0 84 153 71 172 78 185 79 10.0 84 20.4 10Z 250 1.05 1.59 1.81 2.14 2.47 2.69 3.00 3.28 3.33 3,60 4A0 13.7 11.0 11.3 10.9 10.2 10.1 9$ 9.7 9.7 9.5 9.1 284 19.1 17.4 15..8 133 12.9 11.9 11.3 11.0 10.5 17 40.1 30.9 20.8 26.7 29.6 23.1 21.7 21.1 20.6 200 17.8 • The lone Tenn thermal sesi tenze QTTH) values were dieetmlhtee In accordaece with CAWWIt 5778 "Value represeale average results Nonslarderd thicknesses ere evaaatde. Coated your AI sales sepreseraadw for mass information. R9 -5137 8-09 (Replete', 6-09) May. 14. 2010 10:52AM • diar Johns Manville Intermountain Seattle No. 0132 P. 1 Single Ply Roofing Systems (PVC) JM PVC si 50 0 60 ❑ 80 ,. . Description JM PVC is a flexible. thermoplastic membrane manufactured using an ultraviolet- resistant polyvinyl chtoride and an Braley' KEE (ketone ethylene ester) formulation. JM PVC membranes are reinforced with a non - wicking polyester fabric. JM PVC membranes provide excellent weathering characteristics, high tensile strength and Tong -term flexibility. JM PVC membranes also have excellent resistance to harsh chemicals and industrial pollutants. Use JM PVC membranes con be installed in new, reroof (tear -off) and recover roof constructions. In recover construction, if the existing roof is sound, the Johns Manville (JMI roof system can eliminate the cost of disposing of the original roof. JM PVC membranes are installed over approved cushioning layers or insulations, when required. The membrane is secured to the roof deck utilizing either mechani- cal fastening methods that have been tested for wind uplift in both static end dynamic pressure vessels, or adhering the membrane to an acceptable substrate. JM PVC membranes are thermoplastic; therefore, when rolled out onto the roof substrate, they can be easily welded into one homogenous sheet using hot sit welding proce- dures. Since the JM PVC membrane utilizes a non - wicking reinforce- ment, the application of an edge sealant is not required. Colors White, Grey and Sandstone Special colors are available with extended lead times. Minimum order quantities may apply. Contact your local JM sales representa- tive for additional information. Sizes Available in 50 mil, 60 mil and 80 mil thicknesses in the following sheet dimensions: 50 mil 78•1100' (2.0 m x 30.5 m) 39'x100'(1.0mx30.5m) 60 mil 78'400' (2.0 m x 30.5 m) 39'x100' (1.0 m x 30.5 m) 80 mil 78 "x 75' (2.0 m x 22.9 ml 39°x75'(1.0mx22.9m) Applicable Standards JM PVC membranes meet or exceed all of the requirements of ASTM D 4434, Type III. In addition, JM PVC mechanically fastened and adhered roof systems are classified by UL (Underwriter's Laboratories, Inc.). ULC (Underwriters Laboratories of Canada) and FM Global. JM membranes meet the materiel requirements of the International Dulling Code. Limitations JM PVC membranes are mechanically fastened or adhered to the structural roof deck according to FM Global requirements, published standard fastening patterns or adhesives reeommendations. The membranes should not some into direct contact with asphalt, coal tar pitch or any petroleum -based product. • 0 0 Energy and the Environment ENERGY STAR° Pass Reflectivity: 088 Title 24 Pass Reflectivity: 0.88 Emissivity: 0.86 Reflectivity: 0.86 Emissivity: 0.94 Recycted Content Post Consumer. 0% Post Industrial: 2.5% Producing Location: Pawtucket, RI LEO) Results shown are for the initial reflectivity and eminence for white membranes; emissivity values for Title 24 ere tested per ASTM C 1371; TEED emissivity values are tested per ASTM E Placement of of JM Membrane JM specifications require acceptable wood Hailers to be installed according to FM Global current recommendations in Loss Prevention Data Sheet 1-49 and current JM Detail Drawings. Insulation must neatly fit around all the roof penetrations and projections. Insulations used must be accepted by JM for use in the system to be installed. Fastening of the insulation must be in strict accordance with JM standard fastening requirements and/or any applicable code requirements. whichever is most restrictive or required by the building owner. Method of Attachment See product guide specifications for proper installation methods and additional technical data Guarantees JM provides full system guarantees as outlined below Y0 year 60 m0, 80 mil 15year 50.80 and 80 mil 10 year 50, 60 and 80 mil For detailed guarantee information, see the JM system guarantee chart. JM PVC-50,60 and 80 membranes meet or exceed all of the require- ments of ASTM 0 4434. Type III. Typical Physical Properties Property Breating Strength Elongation at Break Properties After Heat Aging Breaking Strength Etoogatlon Tear Resistance Low Temperature Bend Accelerated Weathering Test Cracking (@lx magnification) Crazing We magnification) Discoloration (elx magnification) linear Dimension Change Change in Weight After Imm on in Water ASTM Test Method Values D 751 11751 0 761 0 751 D 751 D 2130 6 53 0 1204 0 570 >200 Ibslm.135 Mimi >20% >90% of original >90% of original >45 Ibstin. (7.9kNlm) Pass at- 40°FI.40 °C) None None Negligible 1o% Refer to the Material Safety Data Sheet prior to using JM PVC. Material Safety Data Sheet is available by calling 800454 -3103 or online at www.jm.com, N A I L W I N O 11S•0216 3At May. 14. 2010 10:53AM Intermountain Seattle_ Georg) Pocific Corporolion 55 Pak Place, 19th Floor Menlo, GA 30303 Technical Hollins: (800) 2254119 18-6 ET) Web She: www.gp.com /gypsum ESCRIPTION. DensDeck° Roof Guard is on exceptional fire barrier, thermal barrier and recovery boord used in vane rs commercial roofing systems. The patented DensDeck design employs glass mai facings front and bock that are embedded into a waterresistont gypsum core, providing excellent fire resistance, moisture resistance and wind uplih properties. The unique construe. Lion of DensDeck provides superior flute spanning that stiffens and provides increased Foot rroffic resistance to the roof deck. Additionally, DensDeck has been shown to withstand delomination, deteriorolion, warp- ing and fob-site damage more effectively ikon roofing membrane substrates such os popes. faced gypsum board, fiberboard and petite insu lesion. DensDads resists the growth of mold and mildew per ASTM D 3273. Roof system manufacturers and designers hove found DensDeck roof boord lo be cam polibte with many types of roofing systems, including: built-up, modified bitumen, single ply, metal systems, wood shingle and shake, rile, slate, recover board, as well as 011 over - layment protection board for polyisocyonurate and polystyrene Insulation. DensDeck con oleo be used as o form board for poured gypsum concrete deck in roof applications as we0 as o substrate for spray foam roofing systems. W and W DensDeck may oho be used in vertical oppllcolions as a backer board or finer For the roof side of parapet walls. Some membrane manufacturers hove her mop osphah or torch applications directly to DensDeck wiihoui using o primer or base sheet. Consul with the system manufacturer for their recommendations with This appllcalion. System manufacturers and designers hove found DensDeck to be compatible with bond ing adhesives for fullyudhered singleply membrane opplicotions. DensDeck's exceptional moisture resistance and low Rivolue make it the preferred subslrote lot vapor retarders. An excellent fire barrier, DensDeck features o noncombusiibte core and inorganic surface No. 0132 P. 3 TDENSDECK Roof Guard that offers greater ire prolection than other conventional commercial roofing products when applied over combustible roof decks and sleet decks. DensDeck is FM tested and approved as the only W gypsum product to meet the colorimeter requlrements for con- ventionally insu(oied decks. Tested in accor- dance with ASTM E 84, Its surface burning characteristics ore Flame Spread0 and Smoke Developed°. W DeruDedt can replace any generic Type X gypsum board In any roof assembly In the UL Fire Resistance Directory under Ilse prefix "P' LIMITAnONS DensDeck Is designed to act with a properly designed roof system. The actual use of DensDeck Roof Guard os a roofing component is the responsibility of the roofing system's designing outhoriy. Georgio?ocfic does not offer roofng system design services. Conditions beyond the control of Georgia-Pacific such as weather conditions, dew, application temperoturos and techniques may cause adverse effects with adhered roofing systems. Always consvh roof ing manufacturers for their specific iaslru° lions on applying their products to DeruDeck Roof Guard. Panels must be kept dry before, during and after lnstollotIon. Apply only as much DensDeck as can be covered by a roof membrane system in the some day. Accumulation of water due to leaks or condensorion In or on DensDeck Roof Guord musi be avoided during aonsbuction and after construction. Avoid overuse of non•venied directfired healers during winter months. Avoid apptcotion of DensDeck during rains, heavy fogs and other conditions that moy deposit moisture 011 the surface. The need for a separator sheet between the DeriDedc Roof Guard and the roofing membnsne • shah-be-determined by the roof membrane manufacturer or roofing systems designer_ When applying sokonrbosed adhesives or primers, allow sufficient lime (or the solvent lo flash off to avoid damage to roofing components. Maximum Rule span is 2W for W DensDeck; S" for W DensDeck: and 8, for 34" DensDeck Fireguard° Type X. s /s( DensDeck is not recommended for vertical parapet applications. Hol mopping directly to DensDeck: 1_ For full mopping opphtanons, use osphah hooted to a maximum application tempera- lure of 425° F. (Type III asphalt) 2. If Type IV Is required because of slope limi- tations, consider the use of ribbon or spat mopping, or the Instollalion of o perforated base sheet. 3- Full mopping el fully mohair coated fens or irnpermeobte base sheets such as modified bitumen Is nor recommended. 4. Ensure that proper pressure is opplied to the roll to make contact with the DensDeck. Use o broom to press the mem- brane into place. Torch applied directly to DensDeck: 1. Prime the surface of the DensDeck and allow lo dry thoroughly, or use DensDeck Prime. 2. Ensure proper torching technique. limit the (seal so the DsnsDock substral°. Maintain a ma(orly of Ithe torch flame directly on the roll. 3. Use Rat insulation pious. 4. Ensure proper pressure is applied 10 the membrane roll to make contact. Browning may be required al the end of rolls. 5. Consider the use of strip or spol torched base membranes to allow the lateral move• men) of moisture. Consub membrane manufacturer for specific system inhalation InstrucTtone. Horne spread 0, smoke developed 0, when tested In accordance with ASTM E 84 or CAN /UICS102. Noncombusiible when tested In accordance with ASTM E 136. DensDeck Fireguard: UL Classified when IesF ed in accordance with ASTM E 119. lib" DensDeck has been tested by Factory Mulual for 60 psf.ond 90 psi wind uplih for BUR EPDM, lhermoplaslks and modified blhr men -root systems. Higher wind upl h wrings hove been achieved by numerous membrane manufacturers using DensDeck in their FMRCopproved tanslruction designs. NSTPu ri0t 1- DensDeck should be used with fasteners specified In accordance with FM require• menis and roof membrone rnanuloclurees warren recommendations. 2. For wind uplift /FMRC compliance wham DensDeck is mechanically attached to metal decks, DensDeck shall be installed 10 the specifics of the FMRC design assembly May. 14. 2010 10:53AM Intermountain Seattle 3. For installations involving BUR, EPDM, ther- moplastics and modified bitumen roof systems, cell the G-P Technical Hotline 011-800-223-6119 for fastener patterns of GP's FMRC uplift assemblies. 4. In accordance with approved shop drawings, FM•approved fasteners shall be Installed with plates through the DensDecic, push with the surface. 5. Where DensDeck is installed over com- bustible wood decks or insulation, all joints should be staggered. The optional separa- tor sheet should be installed prior to DensDeck installation. 6. Edge taints should be located on, and par- allel lo, deck ribs. End loinls of adjacent lengths of DensDeck should be staggered. 7. The securement of the roof system must be enhanced al the building corners and perimeter per FM. 8. Adhered Systems: testa -Foam Products, Inn's InstaSi& Adhesive used with %( DensDeck achieved 2o FMRC Class 1180 according to test report 1r7A5.AM in seleded Class 1 insulated steel and concrete deck roof oonstrudion. Contact Instao-foam Products, Inc. for detais at 1- 800- 800.FOAM. 9. DensDeck shall be installed with ends and edges butted Tightly. 10. DensDeck is manufactured to conform to ASTM C 1177. No. U132 P. 4 ODUCT; 1Al Thickness:.4 j6.4mrn); W (12 Awn); W (15.9mm) fireguard' Type X Widths: 4' 11220mm) standard, '/i' l3mm) tolerance Lengths: 8' (2440mm) standard, tolerance 16.4mm); Optional. 4' 11220mm) available; other lengths special order Edges: Square Spanning: s/: DensDeck spans flute widths up to 236 "; s/!' DensDeck spans (lute widths up to 5 '; 411' DensDeck spans flutes up to 8' wide ;Thr"crcrrii'ess; Roh+lna�•1,.,!le3 nY `",�q<•`;�j,�'yi,�' Strength, Porollel, lbs. min.' 4p' ° "" -� ct..,_ e____e.�•.. 4tL :ist�v��L�:�L�.�w,+.cr��+�e��j ..�..7 � a� ���,'�Y'"`. ` _,_ .. • 111;11�(l�if} 'Tested in accordance with ASTM E 601 (400 lb. conc. toad). 'Tested in accordance with ASTM C S56 (dry cup method). 'Tested in accordance with ASTIR C 518 (heat now meter). U.S.A. Midwest: South: Northeast: West: Technical Information U.S.A. and Canada: 1-800-225-6119 Man.-Fri., 8 a.m. -6 p.m. Sales Information 1- 800 -876 -4746 1- 800.327 - 2344 1- 800. 947 -4497 1- 800. 824 -7503 and Order Placement CANADA Canada Toll Free: Quebec Toll Free: Canada Toll Free Fax: 1-800-387-6823 1 -800- 361 -0486 1.800- 387 -8975 Or visit our Web site al www.gp.com /gypsum. 11 -01 -2010 Dep Fitment of Community /reVelOpment ROOF DOCTORS, ATTN DAVE PO BOX 48321 SEATTLE WA 98166 RE: Permit No. D10 -128 5920 S 180 ST TUKW Jim Haggerton, Mayor Jack Pace, Director Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date time afte�the work has,begundfo building a period of 180 authorized by such permit is suspended or abandoned at any days. Your permit will expire on 12/20/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 12/20/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer Marshall it Technician File: Permit File No. D10 -128 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206- 431 -3670 ® Fax: 206- 431 -3665 • PERMIT COORS COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -128 DATE: 05/17/10 PROJECT NAME: FIDELITY BUILDING SITE ADDRESS: 5920 S 180 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued EPARTMENTS: 4-HO l mg vision Public Works AVVItt Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete tg Comments: Incomplete ❑ DUE DATE: 05/18/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route tg Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06/15/10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prjr Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Dgk Enterprises Inc UBI No. 602638180 Phone 2538647022 Status Active Address 17404 Meridian E Ste F Pmb 162 License No. DGKENEI9420F Suite /Apt. License Type Construction Contractor City Puyallup Effective Date 9/6/2006 State Wa Expiration Date 9/6/2010 Zip 98375 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company censes License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HAR00 "110QT H &Amp; A Roofing Construction Contractor Roofing Carpentry/Framing 11/30/1989 11/1/1996 Archived JDENTI *97604 J &Amp; D Enterprises Inc Construction Contractor General Unused 9/24/2003 9/27/2007 Expired HAR00 "044PD H &Amp; A Roofing Construction Contractor Carpentry/Framing Roofing 10/4/1996 9/27/2003 Inactive Business Owner Information Name Role Effective Date Expiration Date Kurtze, Dave G President 09/06/2006 Amount Kurtze, Joan I Vice President 09/06/2006 FMIL002771 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 AMERICAN STATES INS CO 6442482 09/01/2006 Until Cancelled $12,000.00 09/06/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 FIRST MERCURY INS CO FMIL002771 09/07/2009 09/07/2010 $1,000,000.0009 /04/2009 3 FIRST MERCURY INS CO FMIL003647 09/07/2008 09/07/2009 $1,000,000.00 09/04/2008 2 FIRST MERCURY INS CO FMIL002771 09/07/2007 09/07/2008 $1,000,000.00 08/31/2007 1 FIRST MERCURY INS CO 2079056A 09/01/2006 09/01/2007 $1,000,000.00 09/06/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 06/01/2010