Loading...
HomeMy WebLinkAboutPermit D10-145 - WASHINGTON MULTI-FAMILY HOUSING - OFFICES, MULTI-PURPOSE ROOM AND STORAGEWASHINGTON MULTI - FAMILY HOUSING 18200 CASCADE AV S SUITE 103 D10 -145 City oPf u kwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 7888900170 Address: 18200 CASCADE AV TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D10 -145 Issue Date: 06/17/2010 Permit Expires On: 12/14/2010 Tenant: Name: WASHINGTON MULTI - FAMILY HOUSING Address: 18200 CASCADE AV S - SUITE 103 , TUKWILA WA Owner: Name: RIVERPOINT TWO LLC Address: 1100 OLIVE WAY #1005 , SEATTLE WA 98101 Phone: Contact Person: Name: PAUL ENGERT Address: LANCE MUELLER & ASSOCIATES , 130 LAKESIDE AV - SUITE 250 98122 Phone: 206 - 325 -2553 Contractor: Name: SMAJIC CONSTRUCTION LLC Address: 12219 SE 65TH ST , BELLEVUE WA 98006 Phone: (206)419 -8090 Contractor License No: SMAJICL954R2 Expiration Date: 12/22/2011 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT INCLUDING NEW OFFICES, MULTI - PURPOSE ROOM AND STORAGE. THE SUSPENDED CEILING, LIGHTING AND HVAC SYSTEMS ARE CURRENTLY INSTALLED WITHIN THE SPACE. Value of Construction: $60,000.00 Fees Collected: $1,754.16 Type of Fire Protection: SPRINKLERS / AFA International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 * *continued on next page ** doc: IBC -7/07 D10 -145 Printed: 06 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us Permit Number: D10 -145 Issue Date: 06/17/2010 Permit Expires On: 12/14/2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Private: Public: Profit: N Non - Profit: N Private: Public: N xami with, Date: 040 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this per .J' does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • e ��, r: nce o - ? I am authorized to sign and obtain this development per 't. Ilk Signature: Al Date: Print Name: i/tVL% S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -7/07 D10 -145 Printed: 06 -17 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 7888900170 Permit Number: D10-145 Address: 18200 CASCADE AV TUKW Status: ISSUED Suite No: Applied Date: 06/03/2010 Tenant: WASHINGTON MULTI - FAMILY HOUSING Issue Date: 06/17/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D10 -145 Printed: 06 -17 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) doc: Cond -10/06 D10 -145 Printed: 06 -17 -2010 A i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (I•C 104.2) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -145 Printed: 06 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: /)tip s 4y Date: doc: Cond -10/06 D10 -145 Printed: 06 -17 -2010 CITY OF TUKWIL• Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.eLtukwila.wa.us • Building Permit No. I) 10- 1 Mechanical Permit No Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 7888900170 Site Address: 18200 Cascade Ave South - First Floor Suite Number: 103 Floor: 1 Tenant Name: Washington Multi - Family Housing New Tenant: 0 Yes 13 ..No Property Owners Name: O'Keefe Development Mailing Address: 1100 Olive Way, Suite 1005 Seattle WA 98104 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Paul Engert - Lance Mueller & Associates Mailing Address: 130 Lakeside Ave Day Telephone: (206) 325 -2553 Seattle WA 98122 E -Mail Address: pengert@Imueller.com City State Fax Number: (206) 325 -2553 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Smajic Construction, LLC Mailing Address: 12219 SE 65th Street Bellevue WA 98006 City State Zip Day Telephone: (206) 419 -8090 Fax Number: (425) 378 -2593 Contact Person: Adi Smajic E -Mail Address: smajic @msn.com Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Same as contact above Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:Upplications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORIS`ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 60,000 Existing Building Valuation: $ 2,000,000 Scope of Work (please provide detailed information): Interior tenant improvement including new offices, multi - purpose rou and storage. The suspended ceiling, lighting and HVAC systems are currently installed within the space. Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 414 ❑ Yes Compact: 207 Handicap: 14 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes , attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la` Floor 26,882 0 0 V -B B 1514, $ 21'd Floor 28,882$a 0 0 V -B B 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 414 ❑ Yes Compact: 207 Handicap: 14 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes , attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: A ! HOBWEDDKGENT: Print Name: Paul Engert Mailing Address: pengert@Imueller.com Date: 06/03/2010 Day Telephone: (206) 325 -2553 Seattle WA 98122 City State Zip Date Application Accepted: . O Date Application Expires: I�— Staff Initials: � (.17 1 3 (d H:'Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7888900170 Permit Number: D10 -145 Address: 18200 CASCADE AV TUKW Status: APPROVED Suite No: Applied Date: 06/03/2010 Applicant: WASHINGTON MULTI - FAMILY HOUSING Issue Date: Receipt No.: R10 -01090 Payment Amount: $1,064.90 Initials: JEM Payment Date: 06/17/2010 02:57 PM User ID: 1165 Balance: $0.00 Payee: ADNAN SMAJIC, SMAJIC CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01431G ACCOUNT ITEM LIST: Description 1,064.90 Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,064.90 1,060.40 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://wwwci.tulcwila.wa.us RECEIPT • Parcel No.: 7888900170 Permit Number: D10-145 Address: 18200 CASCADE AV TUKW Status: PENDING Suite No: Applied Date: 06/03/2010 Applicant: WASHINGTON MULTI - FAMILY HOUSING Issue Date: Receipt No.: R10 -00980 Initials: WER User ID: 1655 Payment Amount: $689.26 Payment Date: 06/03/2010 08:57 AM Balance: $1,064.90 Payee: LANCE MEULLER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 28600 689.26 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 689.26 Total: $689.26 PAYMENT '3ECEIVFD doc: Receipt -06 Printed: 06 -03 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION O. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pro-i Project: {A1pr ✓7"v Type of Inspection: F WA L 5) , ( Li A6 Address: /82-00 Onsce'9 'u S, Date Called: 1 Special Instructions: / .C�yZ.3�C - 0 / Date Wanted: 7- 2c--)0 a.m. c Requester: Phone No: 6204,- y/5 -809-0 (Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Insdector: Date: f ❑ $60.00 REINSPECTION FEE RE ' UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., , ite 100. Call to schedule reinspection. Receipt No.: Date: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Q(4 -('1 Project u,4- we�TLIAe Uvu4in Type of Inspectiop: 6/42- 46, d 1?,(16 e_456.46ke Address: Date Calle :�S l t Special Instructions: /Phone // Date Wanted: 1 '7 —(d a.m. Requester: No: c '2i0 6 -l-4'05 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1, Inspec>ior: ,40 Dater n r tU El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1`1206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: W A.r� I r . J 6 ,UN f\'���.,k Ty a of Inspection: A k S1 t s,'CrJ N--CAP; (i4s.1 Address: ('Qj2 OO (° 6,S 6. A D� Date Called: k d , % .''' Special Instructions: 4a 1'/ Al 1 J Date Wanted: �a'•Pn* �1J - ►-� I d Requester: e -/. (/ e„ n; f- _--1 -7 Phone No: aC) 6: ti tel — 90c v DApproved per applicable codes. Corrections required prior to approval. COMMENTS: (I 0 nit as& 4 .''' '. & -'( 1 S 1`r' . ' c -J -J 1)0 PA( (7) Al S D f k 4-0-49 L.,.) ; / .& 5 A ,.� A t) ke -7� e -/. (/ e„ n; f- _--1 -7 j i ) - t?) /-,a cr- -- .13(11— ichu -`r,k e 0 -ru , ^sneC - kfAulA 2 Aey r S ) 9/0 Je 1 Inspect r: Date: - Z 2- —( ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. GM 40 10 -14 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proj ct . ( It' A . t Type o nspecti n: • a AA . ✓� Addre s: 1 '1,40 a 64fc Date Called: "1-e-) Special Instructions: Ayi)(1).10 Date Wanted: ! m. Requester: Phone ( 0 - l 1 7 __EN 7 o Approved per applicable codes. Corrections required prior to approval. COMMENTS: rk-r-r. A t A 6 pf , f n p c.) -,)t..-c'sjr "1-e-) ,V k .e,t-r-4_,6,.( Ayi)(1).10 Inspdktor: Date: LDS ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NUMBER Nth" "yI 4 , rc 'UU. � .dJtla.��6aC M4LCd' . IN11 �i7 INSPECTION RECORD Retain a copy with permit .D 1 b — 13 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: y w I,6.• , ,,,f, ., kiv-s If/ 0$ Fire Alarm: Type of Inspection: 'c 1 ;,, 4„/ Address: Jrzgoo. Suite #: /(93 c c% se a dm A ✓ S • Contact Person: i Special Instructions: Phone No.: E'Pproved per applicable codes. nCorrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: 1 Fire Alarm: Hood & Duct: / Monitor: Pre -Fire: Permits: Occupancy Type: i N. Inspector: ocili ‘3 1 Date: 7/25A 0P Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 y INSPECTION NUMBER • • INSPECTION RECORD Retain a copy with permit 1 •o•""•• . l' Jju191M'','a.r AO- S-132. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: + d4.- ,mss,,,,, ti . ' Type of Inspection: Co..4.,. -:4 / Address: it z e) co CA.se epeat. 4.49.- 5 Suite #: /03 Contact Person: "4 J,/f; Special Instructions: Phone No.: 2.)c- <<i9- Po Hood & Duct: proved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Hre Alarm: Hood & Duct: Monitor: , _ Pre -Fire: ''Permits: _ Occupancy Type: r7 4. - . �, u '/W .. .a Date: 7,012 L,/a Hrs.: i Needs Shift Inspection: Sprinklers: Hre Alarm: Hood & Duct: Monitor: , _ Pre -Fire: ''Permits: _ Occupancy Type: Inspector: •+ ' .3 • • .a Date: 7,012 L,/a Hrs.: i $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of.:Tukwila'Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/0.6 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila, Wa. 98188 206 -575 -4407 Project: t4,43 ,.mi a ,, ..,r 1 Type of Inspection: 6 "r- A44; ....K.► Address: /t Suite #: /p3sL Cdase4,416 Ale. 3. Contact Person: Special Instructions: Phone No.: 3c', -- `fciI — G3Z alt Approved per applicable codes. Corrections reu it .r COMMENTS: 11' for to approval. 5 7 ;, 5 ,h s v >� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: ,, 3,J /A Hrs.: • $80.00 REINSPECTION FEE,.REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record FOrm.DOc 1/13/06 T.F.D. Form F.P. 113 ti INSPECTION RECORD Retain a copy with permit • INSPECTION NUMBER • PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: 1 • {_ .. t4.0-.. 4. Type of Inspection: sel C60.4, ec Address: / o Suite #: /b3 ciii.gc ,q,c) 42_ p4aes Contact Person: /`Dr Special Instructions: Occupancy Type: Phone No.: nApproved• per applicable codes. KCorrections required prior to approval. COMMENTS: 10 Do got) a iz c_P ,J1/4-kr v Spp L< OK C AJ-te /► Aunt 4C( .9s -to cAe ti tigAJoick Needs Shift Inspection: Sprinklers: 'Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: .1/1. 5-g-- Date: 7/07040 Hrs.: x n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ? 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Project Info Project Address Washington Nutli- Family Housing Date 6/3/2010 18200 Cascade Ave South For Building Department �v/ FI L p� COP S ApFe9 ®O' Tukwila, Washington Applicant Name: Lance Mueller & Associates - c*- -t e� Applicant Address: 130 Lakeside Ave, Seattle, Washington �� s Applicant Phone: 206 325 -2553 Project Description ❑ Plans Included requirements. ❑ New Building 1 Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option O Prescriptive O Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Area in ft2 Allowed x Area ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Dl0- ty5 RECEIVED JUN 03 2010 P TC NTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other fication QualiQualification Checklist answer If Is occupancy answer Is checked, the number of fixtures in ed type is "Other" and resin the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section ( 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -9 Untt Lighting Power Allowance Use LPA` (W /sf) Use' LPA1(W/sf) 1.0 Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5''•" Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail70, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall'•° 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • • Joanna Spencer - Re: 18200 Cascade Ave S D10 -145 From: Todd Reedy To: Joanna Spencer Date: 06/09/2010 2:57 PM Subject: Re: 18200 Cascade Ave S D10 -145 Hi Joanna, Page 1 of 1 Backflow testing is current at 18200 Cascade (next tests are due Oct. 2010). If you remember this property shares a fireline connection with 18300 Cascade and I noticed the FDC is a siamese so they need to install a Storz adapter. Todd »> Joanna Spencer 06/09/2010 12:00 PM »> Todd, Are they current on their backflows ? Thanks, Joanna file: / /C: \Documents and Settings \joanna.TUKWILA \Local Settings \Temp\XPgrpwise \4C... 06/09/2010 • 1�,r j � J3 .'�, f , 4 t 'ja ` .: x, PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -145 DATE: 06 -03 -10 PROJECT NAME: WASHINGTON MULTI- FAMILY HOUSING SITE ADDRESS: 18200 CASCADE AV S - SUITE 103 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BuTdi Dlvislon Pt(btid Wo "r'ks 011‘ Prevention Nil to- 114- I0 Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-08-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: -61 Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-06-10 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pier Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Smajic Construction Llc UBI No. 602566567 Phone 2064198090 Status Active Address 12219 Se 65Th St License No. SMAJICL954R2 Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 12/22/2005 State Wa Expiration Date 12/22/2011 Zip 98006 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date Smajic, Adnan Partner /Member 12/22/2005 Amount Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG4819 12/15/2005 Until Cancelled $12,000.00 12/22/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 CBIC C11SG4819 12/15/2007 12/15/2010 $1,000,000.00 10/28/2009 1 CBIC C11SG4819 12/15/2005 12/15/2007 $1,000,000.00 10/09/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 06/17/2010 • __ -.�... xmaq f.a"6 °4 • i pANrt"!EK '-- N11:019001 NC CASCADE AVENUE SOUTH 10 BUILDING 1 18300 CASCADE AVE. SOUTH 11. • ■ : 161c1,1 I<<�,IGJ:Fci GIG ti c 6' 14 178'50' E 645.35' -W MINN Went 0 I COWL NIL ICON= 0123 -- crIcIcl{I{ c�c(G LLJJL.. °ce6neae°u "o BUILDING 2 18200 CASCADE AVE. S N 128 :50" E 147.37' ' i 777" �uu emu■ � • b c, ' ('} /`C � l � IIII • ` il. � i , l l � � l � ) i � l ) I I ! I ' � I I I ! [ 1 � � � I � I � � � � N ▪ � I � � I L I - J lG c c, ,.�.. - -� -`-� �`- WEST VALLEY HIGHWAY (_ SITE PLAN / NO SCALE ABBREVIATIONS LPL • "*.••••• z • I 14W n i 1/ C/ c • z ce c ADJ ALT AFF ALUM L ANOD. ACT BLDG. BLK'G. BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FE FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ,ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FIRE EXTINGUISHER FACTORY FINISH FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FT FTIC FURN GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FOOT / FEET FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS 1 GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERMO TYP VAR VCT VEN VERT VWC WI W/0 WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL VARIES VINYL COMPOSITION TILE VENEER VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD C GENERAL NOTES AREA OF WORK THIS PERMIT FIRST FLOOR SEPARATE PERMIT REQUIRED FOR: Kiethanleal eetfical umbirq fibae Aping City of Tukwila BUILDING DIVISION, REVISIONS No granges shall be made to the scope of Work without prior approval of Tukwila Building Division. NOTE: Revisions will requite a new plan submittal and may include additional plan review fees. n VICINITY PLAN NO SCALE FILE COPY Permit No.,1) 0 "" 140 Plan review approval is subject to errors and omissions. /Approval of construction documents does not authorize 1h ; violation of any adopted code or ordinance. Receipt a' approved Field ► ,y :.t:, conditions is acknowledged: By Date: City Of TU to BUILDING DIVISION 1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECTS APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. D OTHERWISE. 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECTS APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. 19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4" IN 10 " -0 ". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. tenant improvement Washington Multi-Family Housing 18200 Cascade Avenue South Tukwila,WA PROJECT NOTES TAX LOT NUMBER: 7888900170 LEGAL DESCRIPTION: SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S 78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N lld 23' 50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11° 2T 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A OF 62D 57' 52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF & PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44° 29' 00" E 96.32 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET S 82° 08' 00 "E 100.00 FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M/U TO W/ MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33' 20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51° 37' 10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.14 FEET ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEET THEN N 78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE II OF CORPORATE PROPERTY INVESTORS BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA BOUNDARY LINE. ZONE: SITE AREA: CONSTRUCTION TYPE: BUILDING AREA: NORTH BUILDING NO. STORIES SOUTH BUILDING NO. STORIES PARKING REQUIRED: PARKING PROVIDED: CODES USED: TENANT AREA: OCCUPANCY: OCCUPANT LOAD: TENANT: SCOPE OF WORK: C / CU 6.58 ACRES V -B FIRE SPRINKLERED 53,625 2 53,625 2 278 STALLS 414 STALLS 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONALFIRE CODE 2006 WASHINGTON STATE ENERGY CODE 2006 WASHINGTON STATE BUILDING CODE 2006 PLUMBING CODE 2006 MECHANICAL CODE 2003 ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES 1,582 USEABLE SQ. FT. (FIRST FLOOR) B - OFFICE 100 SQ. FT. /OCCP. 1,582/100 = 16 OCCUPANTS WASHINGTON MULTI - FAMILY HOUSING INTERIOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF APPROXIMATELY 1,582 SQ. FT. THE WORK CONSISTS OF BUILDING NEW OFFICES, DOORS AND MULTI - PURPOSE -ROOM. THE SPACE CURRENTLY HAS A COMPETE SUSPENDED ACOUSTICAL TILE CEILING AND LIGHTING SYSTEM. A PORTION OF EXISTING LIGHT FIXTURES WILL BE RELOCATED: THE SPACE WILL BE ACCESSED BY MEANS FOR AN EXISTING NON -RATED HALLWAY. BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: O'KEEFE DEVELOPMENT COMPANY 1100 OLIVE WAY, SUITE 400 SEATTLE, WA 98101 T. (206) 236 -6200 F. (206) 236 -6160 CONTACT: HARPUR DAVIDSON EMAIL: harpur @okeefedevelopment.com LANCE MUELLER & ASSOCIATES 130 LAKESIDE AVE SEATTLE, WA 98122 T. (206) 325 -2553 F. (206) 328 -0554 CONTACT: PAUL ENGERT EMAIL: pengert @Imueller.com SMAJIC CONSTRUCTION, LLC 12219 SE 65th STREET BELLEVUE, WA 98006 ' T. (206) 419 -8090 F. (425) 378 -2593 CONTACT: ADI SMAJIC EMAIL: smajic @msn.com DEFERRED SUBMITTALS 1. PLUMBING WORK UNDER SEPARATE PERMIT 2. MECHANICAL WORK UNDER SEPARATE PERMIT 3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT INDEX OF DRAWINGS TAI.1 TA2.1 TA2.2 TA2.3 TA3.1 TA3.2 ■ COVER SHEET / SITE PLAN 1/16" OVERALL BUILDING PLANS 1/8" SECOND DEMO. / FLOOR PLANS 1/8" SECOND CEILING PLAN WALL SECTIONS / CEILING DETAILS DOOR SCHEDULE / INTERIOR ELEVATIONS / DETAILS b1O ICE REVIEWED FOCODECOMPL IA AM 17 MO City of Tukwi a BUILDING Divigirnl RECEIVED JUN 03 2010 PERMIT CENTER ys I= _ uJ Lw 0 0 rn ru J uJ w J 1 w 3 Z J 0. w Cn w J W sheet U) cc U 0 TA 1.1 MIA (2 06) 325 -2553 l-° N N w H ul I• w 0 U u, w - J 0 Q m CO • M Co i-.0_ Q) 17 'd PERMIT SUBMITTAL 1 0 0 N 0 10 -050 job no. P. ENGERT drawn P. ENGERT checked 05 -28 -10 date I= _ uJ Lw 0 0 rn ru J uJ w J 1 w 3 Z J 0. w Cn w J W sheet U) cc U 0 TA 1.1 MIA (2 06) 325 -2553 l-° N N w H ul I• w 0 U u, w - J 0 Q m ,000 0 LGOCKDj EGRESS PATHWAY 77-7 iy FLOOR -2 OVERALL PLAN \ 1116" =1' -0" 9 J J 0 77-0' 77-0' EGRESS PATHWAY A 0 EGRESS PATHWAY -E1J-- -i 22-11' ?7.10' 71'•10' 22.10' 77.1P 27-10. 72.11' N m 10747 . v.-, C 0 .y 'S N ,....■ ...t EXIT 77-0' 77.0' AREA OF WORK THIS PERMIT 77-0` COMMON PATH OF TRAVEL = 50' / e/ (_ 3FLOOR -1 OVERALL PLAN 1/16" =1' -0" REVIEWED FOR CODE COMPLIANCE AP'RnvEn JUN 17 21110 City of Tukwila BUILDING nivimm RECEIVED JUN 0 3 2010 PERMIT CENTER o w cc V w CD cc ,_ O D) E m ca lam z �.r L G 0 co w_ a OEQ� w U 0 UJ N N Q� 3 � Q W wN z J `J J �- o_ Fin N W w w • e I • W Z Z Et ; 0 Q J J J a m m sheet (206) 0 TA2.1 06/03 /08 • N m PERMIT SUBMITTAL C 0 .y 'S N O C •ou qof 050-0I. P. ENGERT drawn _P.ENGERT checked 0 �1 ) `6 -o o w cc V w CD cc ,_ O D) E m ca lam z �.r L G 0 co w_ a OEQ� w U 0 UJ N N Q� 3 � Q W wN z J `J J �- o_ Fin N W w w • e I • W Z Z Et ; 0 Q J J J a m m sheet (206) 0 TA2.1 C15 22' -U" 22' -0" 11 4 N 4 (_ FLOOR -1 DEMO. PLAN �� 118" =1' -O" FLOOR DEMO. KEYNOTES 1. OPENING IN EXIST. WALL FOR NEW DOOR AND SIDELIGHT. DEMOLITION SYMBOLS & LEGEND EXISTING WALL TO BE REMOVED EXISTING WALL TO REMAIN 12) (13 17E ' -O" 22' -0" 22' -O" 22' -0" 221 -0" 22' -0" 22' -0" 22' -U" 1 1 10 x WOMEN'S r3 0 WOMEN'S SHOWERS 11 MEN'S SHOWERS HALLWAY FITNESS CENTER LEASE SPACE N ARCHITECTURAL SYMBOLS & LEGEND EXISTING WALL TO REMAIN NEW WALL PER PLAN NEW WALL W/ SOUND INSULATION PER PLAN DOOR NUMBER EX. = EXIST DOOR TO REMAIN ELEVATION LETTER ELEVATION NUMBER INTERIOR ELEVATION SYMBOL SHEET NUMBER OFC. (105) FEC 0 ROOM NAME & NUMBER WALL TYPE REFERENCE DETAIL NUMBER DETAIL REFERENCE SHEET NUMBER DETAIL NUMBER SECTION REFERENCE SHEET NUMBER SEMI - RECESSED FIRE EXTINGUISHER CABINET SURFACE MOUNTED FIRE EXTINGUISHER 19' -0" 6' -0" 3' -0" 4'-10" " UP 0 STORAGE (102) - +42' r-1 LI 0 101 1 +42" Q4 107 MULTIPURPOSE ROOM (103) 26' -0" ELECTRICAL SYMBOLS & LEGEND CV m 0 10" ALIGN 106 OFC. 105 EQ. EQ. ELECTRICAL OUTLETS, LIGHTING AND SWITCHING SHOWN FOR GENERAL DESIGN INTENT. ELECTRICAL CONTRACTOR TO CONFIRM ELECTRICAL REQUIREMENTS WITH TENANT PRIOR TO ANY WORK. dIMER DUPLEX ELECTRICAL OUTLET 110V DEDICATED DUPLEX ELECTRICAL OUTLET 110V FOURPLEX ELECTRICAL OUTLET 110V DEDICATED FOURPLEX ELECTRICAL OUTLET 110V TELEPHONE /DATA OUTLET ELECTRICAL OUTLET W/ TIMER FLUSH FLOOR ELEC. / DATA BOX ELECTRICAL JUNCTION BOX SYSTEM FURNITURE POWER POLE LOCATION (CONFIRM W/ FURNITURE VENDOR) SYSTEM FURNITURE BASE POWER FEED (CONFIRM W/ FURNITURE VENDOR) 101 -0" 12'-4" N CV 4 co () FLOOR -1 FLOOR PLAN `� 118" = l' -0" FLOOR PLAN KEYNOTES 1. CENTER DOOR IN WALL. 2. ALL FURNISHINGS BY TENANT. 3. SEMI - RECESSED FIRE EXTINGUISHER CABINET. SEE DETAIL 20 / TA3.2 4. BUILT -IN UPPER & LOWER PLASTIC LAMINATE CASEWORK. REVIEWED FOR CODE COMPLIANCE JUN 17 211itl City of Tukwila BUILDING nhUi inn, RECEIVED JUN 03 2010 PERMIT CENTER cu E 0 E c 1= 0 old Imo cgs 1 D) m 0 Z C� CV V � 2 w c o Q a C O v as co 'o U c BOO • [7 N N CO a 0 Wcn sheet TA2.2 06103/08__ 0 m v PERMIT SUBMITTAL c 0 '5 0 c 'au qof 090-01, P. ENGERT drawn P. ENGERT checked 0 ;TS cii o m f° -o cu E 0 E c 1= 0 old Imo cgs 1 D) m 0 Z C� CV V � 2 w c o Q a C O v as co 'o U c BOO • [7 N N CO a 0 Wcn sheet TA2.2 1 I NMI MIDI A j I ILusim■ ilak. H1*1lli 1 CEILING / LIGHTING SYMBOLS f 0 r la EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE CEILING AND GRID SYSTEM EXISTING GWB CEILING EXISTING 2' x 4' BLDG. STD FLUORSCENT LIGHT FIXTURE EXISTING RECESSED COMPACT FLUORESCENT HALLWAY LIGHT FIXTURE EXISTING LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) EXISTING 2' x 4' BLDG. STD FLUORESCENT LIGHT FIXTURE TO BE REMOVED OR RELOCATED NEW OR RELOCATED 2' x 4' BLDG. STD FLUORSCENT LIGHT FIXTURE NEW LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) NEW DIRECTIONAL LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) EMERGENCY EGRESS PATHWAY LIGHT FIXTURE (MIN. LIGHTING LEVEL IS 1 FOOTCANDLE AT + 3' -O" FROM FINISH FLOOR MAINTAINED) FLOOR -2 CEILING PLAN 1/8" = 1'-0" GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL INSTALL EMERGENCY EGRESS LIGHTING WITHIN TENANT SPACE TO PROVIDE A MINIMUM OF 1 FOOTCANDLE AT THE WALKING SURFACE. THIS IS IN ACCORDANCE WITH IBC SECTION 1006. ELECTRICAL CONTRACTOR SHALL MEASURE LIGHTING LEVELS ALONG THE COMMON PATH OF EGRESS TO MAINTAIN THE 1 FOOTCANDLE MINIMUM LEVEL TO THE EXIT DISCHARGE. THE EMERGENCY LIGHTING SHALL BE INSTALLED ALONG THE "COMMON PATH OF TRAVEL" SEE SHEET TA2.1 FOR LOCATION 2. SUSPENDED CEILING SYSTEM IS EXISTING THROUGHOUT THE SPACE. SEE SHEET TA3.1 FOR NOTES REGARDING ANY CHANGES OR ALTERATIONS TO SYSTEM. KEYNOTES 1. EXIST. LIGHT FIXTURE TO BE RELOCATED. REVIEWED FOR - CODE COMPLIANCE Apps - nvEn JUN 17 2010 City of Tukwfla BUILDING flI II 1nrg RECEIVED JUN 03 2010 PERMIT CENTER w w iL N w w CD cc CA O 1 ii. num m sop o wig 2 g- co co 13 0 D) cts 206) 325 -2553 I w 0 0 U w J 0 Q m sheet TA2.3 06/03/08 • 0 m v PERMIT SUBMITTAL c 0 .y '5 t_ c c 10-050 job no. P. ENGERT drawn _P.ENGERT checked 0 r- eb a A o `O v w w iL N w w CD cc CA O 1 ii. num m sop o wig 2 g- co co 13 0 D) cts 206) 325 -2553 I w 0 0 U w J 0 Q m sheet TA2.3 IF HANGER WIRE IS OUT OF PLUMB GREATER THAN 1:6 COUNTER SPLAY PER ASTM C636 WALL WHICH PENETRATES CEILING GRID WALL EDGE MOLDING MAX. 8" MIN. 2" MIN. 3/4" @ UN- ATTACHED WALLS EDGE BRACING CEILING SEISMIC BRACING #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE @ EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID #12 HANGER WIRE ANCHORED TO — STRUCTURE ABOVE MAIN BEAM ood SEISMIC JOINT CLIP EXPANSION SLEEVE CEILING EXPANSION JOINT WALL EDGE MOLDING CROSS TEE PER ASTM C635 STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY EDGE BRACING ISOMETRIC X55 kA STEEL STUD COMPRESSION POST ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION #12 HANGER WIRE TYP. TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) O o O CROSS TEE PER ASTM C635 MAIN CEILING BEAM PER ASTM C635 CEILING GRID SEISMIC BRACING NO SCALE SUSPENDED CEILING ARE TO COMPLY WITH THE FOLLOWING CODES AND REGULATIONS: A. 2006 INTERNATIONAL BUILDING CODE (IBC) SECTION 803.9 B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C635 AND ASTM C636 (REFERENCED IN IN 803.9). C. ASCE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 7 SECTION 9.6.2.6 D. CISCA (CEILING & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) RECOMMENDATIONS FOR SEISMIC ZONES 3-4 REFERENCED IN ASCE - 7 SECTION 9.6.2.6.2.2 E. IBC 102.1 STATES "WHERE IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, = METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE ". F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: • ONLY A HEAVY DUTY T -BAR GRID SYSTEM SHALL BE USED. ASTM - 7 SECTION 9.6.2.6.2.ITEM A. • WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE ) SHALL BE NOT LESS THAN 2 INCHES. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM B. • ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A34" INCH CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASTM -7 SECTION • STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND OR CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR ALL EDGES . CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • VERTICAL HANGERS SHALL BE NO. 12 GAGE WIRE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE WIRE SPACED AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED WITHIN 1 :6 OUT -OF -PLUMB UNLESS COUNTER - SLOPING WIRES ARE PROVIDED. • LATERAL BRACING IS REQUIRED. SPLAY WIRES PODS AT 12" MAX. O.C. AND 6' -0" MAX. FROM WALLS. INSTALL TRULY COMPRESSIBLE (E.G. SPRING LOADED) STRUTS OR NO STRUTS AT ALL. RIGID STRUTSARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 3. • CEILINGS OVER 2500 SQ . FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT WALLS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQ. FT. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM D. • FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OF ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF A LEAST 1 INCH IN ALL DIRECTIONS; OR SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM E. • CHANGES IN CEILING PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM F. • CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUSPENDED INDEPENDENTLY FROM THE CEILING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM G. X10-145 ATTACH 2 Yz" x 20 GA. METAL STUDS BRACES TO TOP TRACK W/ (2) - METAL FRAMING SCREWS R CODEpCOMPLIANCE Ato ma) 2Y" x 20 GA. METAL STUDS BRACES @ 8' -0" O.C. (ALTERNATE DIRECTIONS) AT ALL WALL LOCATIONS OVER 12' -0" LONG. ATTACHED TO WOOD FLOOR STRUCTURE ABOVE rn ;4 . .• .4 .4 Pr o . . .; .4 le I, MAKE N( WALL TC SYSTEM EXIST. A CEILING 2Yz" SOU FLOOR P 2Y "x251 24" O.C.1 EACH SI[ Ye" DIA. P FASTENE RUBBE EXIST. C( •• IN ►1 '4! or o : .4 ►' 4 41 .1, 4 • .4 .• •4, Pr ;, • •' :1 .3 .4 •. . o o co v GRADE -- d.. . .• 4. 11- n i-iii c 0 J jii i 7 2010 City of Tukwila BUITYP.OFFI PARTITION 1 /2" = 1' -0" ATTACHMENT OF CEILING GRID OUSTICAL TILE ND INSULATION PER LAN A. METAL STUDS @ JITH 5/" TYPE "X" GWB E WDER ACTUATED RS @ 24" O.C. TYP. R BASE NCRETE SLAB ON RECEIVED JUN 03 2010 PERMIT CENTER w 3 m • CC IWO 1i 1 U � a) a `�<v, >'-°',c U v EL ■t c y 'Q v `a co C O > CV C)) Ca c 0 Z 325 -2553 t0 0 sheet TA3.1 06/03/08 1 o co v PERMIT SUBMITTAL c 0 d c 10 o C 1- o P. ENGERT drawn _ P. ENGERT checked 0 c N o N w 3 m • CC IWO 1i 1 U � a) a `�<v, >'-°',c U v EL ■t c y 'Q v `a co C O > CV C)) Ca c 0 Z 325 -2553 t0 0 sheet TA3.1 WEST STORAGE #103 1/4" =1' -0" 7.4 ANGLED 0 0 WEST WORK #107 CV N ANGLED NORTH 114" =1' -0" 12 CASEWORK KEYNOTES NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE CABINETS NOTE 2. - 12" DEEP UPPER PLASTIC LAMINATE CABINETS NOTE 3. - PLASTIC LAMINATE COUNTERTOP AND 4" HIGH BACK SPLASH NOTE 4. MICROWAVE SHELF NOTE 5. - REFRIGERATOR ALL APPLIANCES TO BE FURNISHED AND INSTALLED BY TENANT 13 5/8" (4 T CV PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. PLASTIC LAMINATE BACKSPLASH & COUNTERTOP CASEWORK SECTION DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE BASE PER SCHEDULE 1" =1' -0" WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT .050 ALUM. BREAK SHAPE TO MATCH EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ FALSE MULLION 3" =1' -0" DOOR SCHEDULE i / ] \l / \ly/ n \ /"N / N HARDWARE GROUP /N / REMARKS N 7 MAT. \I I/z NORTH 114" =1' -0" 12 CASEWORK KEYNOTES NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE CABINETS NOTE 2. - 12" DEEP UPPER PLASTIC LAMINATE CABINETS NOTE 3. - PLASTIC LAMINATE COUNTERTOP AND 4" HIGH BACK SPLASH NOTE 4. MICROWAVE SHELF NOTE 5. - REFRIGERATOR ALL APPLIANCES TO BE FURNISHED AND INSTALLED BY TENANT 13 5/8" (4 T CV PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. PLASTIC LAMINATE BACKSPLASH & COUNTERTOP CASEWORK SECTION DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE BASE PER SCHEDULE 1" =1' -0" WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT .050 ALUM. BREAK SHAPE TO MATCH EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ FALSE MULLION 3" =1' -0" DOOR SCHEDULE DOOR NO. T P E DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS MAT. FIN. MAT. FIN. 101 A 3'-0 "x8-0" WOOD BLDG. STD. H.M. PAINT 1 18" GLASS SIDELITE 102A C 3' -0" X 7-0" WOOD BLDG. STD. WOOD BLDG. STD. 2 102B B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 • 103A C 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 - 103B C 3' -0" X 4'-0" RELITE WOOD BLDG. STD. _ - 104A B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 - 104B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. - - 105 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 --- 106 B 3' -0" X 7 -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 DOOR / RELITE TYPES 3' -0" ,,.1' -6" SOLID CORE WOOD DOOR (MATCH EXISTING SPECIES AND FINISH) MATCH EXISTING BLDG. STD. HOLLOW METAL FRAME 1/4" TEMPERED GLASS 3' -0" WOOD DOOR & FRAME (MATCH EXISTING SPECIE AND FINISH) 2' -8" 4 X" TEMPERED GLASS WOOD SUITE ENTRY DOOR & HOLLOW METAL FRAME W/ SIDELITE HARDWARE GROUPS WOOD DOOR & WOOD FRAME 1. LEVER LOCK SET (SUITE ENTRY FUNCTION) HINGES SILENCERS CLOSER WALL STOP 2. LEVER LATCHSET HINGES WALL STOP 19 WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ VERT. MULLION 3" =1' -0" WOOD FRAME RELITE I v•k 1 Li 5 WALL CONSTRUCTION PER FLOOR PLAN — REVIEWED FOR CODE COMPLIANCE A. ra QED JUId 17 2010 City of Tukwila UILDING nil/1m m i n SEMI - RECESSED FIRE EXTINGUISHER CABINET RECEIVED 20 J SEMI - RECESSED FIRE CABINET JUN 03 2010 3" =1' -0" PERMIT CENTER 0 '5 C E O E c 1 gin CO z sheet TA3.2