HomeMy WebLinkAboutPermit D10-145 - WASHINGTON MULTI-FAMILY HOUSING - OFFICES, MULTI-PURPOSE ROOM AND STORAGEWASHINGTON
MULTI - FAMILY HOUSING
18200 CASCADE AV S
SUITE 103
D10 -145
City oPf u kwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 7888900170
Address: 18200 CASCADE AV TUKW
Suite No:
DEVELOPMENT PERMIT
Permit Number: D10 -145
Issue Date: 06/17/2010
Permit Expires On: 12/14/2010
Tenant:
Name: WASHINGTON MULTI - FAMILY HOUSING
Address: 18200 CASCADE AV S - SUITE 103 , TUKWILA WA
Owner:
Name: RIVERPOINT TWO LLC
Address: 1100 OLIVE WAY #1005 , SEATTLE WA 98101
Phone:
Contact Person:
Name: PAUL ENGERT
Address: LANCE MUELLER & ASSOCIATES , 130 LAKESIDE AV - SUITE 250 98122
Phone: 206 - 325 -2553
Contractor:
Name: SMAJIC CONSTRUCTION LLC
Address: 12219 SE 65TH ST , BELLEVUE WA 98006
Phone: (206)419 -8090
Contractor License No: SMAJICL954R2
Expiration Date: 12/22/2011
DESCRIPTION OF WORK:
INTERIOR TENANT IMPROVEMENT INCLUDING NEW OFFICES, MULTI - PURPOSE ROOM AND STORAGE. THE SUSPENDED
CEILING, LIGHTING AND HVAC SYSTEMS ARE CURRENTLY INSTALLED WITHIN THE SPACE.
Value of Construction: $60,000.00 Fees Collected: $1,754.16
Type of Fire Protection: SPRINKLERS / AFA International Building Code Edition: 2006
Type of Construction: V -B Occupancy per IBC: 0008
* *continued on next page **
doc: IBC -7/07
D10 -145 Printed: 06 -17 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Inspection Request Line: 206- 431 -2451
Web site: http: //www.ci.tukwila.wa.us
Permit Number: D10 -145
Issue Date: 06/17/2010
Permit Expires On: 12/14/2010
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Private: Public:
Profit: N Non - Profit: N
Private: Public:
N
xami
with,
Date: 040
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this per .J' does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the • e ��, r: nce o - ? I am authorized to sign and obtain this development per 't.
Ilk Signature: Al Date:
Print Name: i/tVL% S
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC -7/07
D10 -145 Printed: 06 -17 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 7888900170 Permit Number: D10-145
Address: 18200 CASCADE AV TUKW Status: ISSUED
Suite No: Applied Date: 06/03/2010
Tenant: WASHINGTON MULTI - FAMILY HOUSING Issue Date: 06/17/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431 - 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
7: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: ** *FIRE DEPARTMENT CONDITIONS * **
doc: Cond -10/06
D10 -145 Printed: 06 -17 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (IFC 901.4)
27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
doc: Cond -10/06
D10 -145 Printed: 06 -17 -2010
A i
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
29: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this
project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72
and the City of Tukwila Ordinance #2051.
30: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
31: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (I•C
104.2)
32: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06
D10 -145 Printed: 06 -17 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
Signature:
Print Name:
/)tip s 4y
Date:
doc: Cond -10/06
D10 -145 Printed: 06 -17 -2010
CITY OF TUKWIL•
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.eLtukwila.wa.us
•
Building Permit No. I) 10- 1
Mechanical Permit No
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 7888900170
Site Address: 18200 Cascade Ave South - First Floor Suite Number: 103 Floor: 1
Tenant Name: Washington Multi - Family Housing New Tenant: 0 Yes 13 ..No
Property Owners Name: O'Keefe Development
Mailing Address: 1100 Olive Way, Suite 1005
Seattle
WA
98104
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Paul Engert - Lance Mueller & Associates
Mailing Address: 130 Lakeside Ave
Day Telephone: (206) 325 -2553
Seattle WA
98122
E -Mail Address: pengert@Imueller.com
City State
Fax Number: (206) 325 -2553
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: Smajic Construction, LLC
Mailing Address: 12219 SE 65th Street Bellevue WA 98006
City State Zip
Day Telephone: (206) 419 -8090
Fax Number: (425) 378 -2593
Contact Person: Adi Smajic
E -Mail Address: smajic @msn.com
Contractor Registration Number:
Expiration Date:
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: Same as contact above
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
State
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name: N/A
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
H:Upplications \Forms - Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORIS`ION — 206 -431 -3670
Valuation of Project (contractor's bid price): $ 60,000 Existing Building Valuation: $ 2,000,000
Scope of Work (please provide detailed information): Interior tenant improvement including new offices, multi - purpose rou
and storage. The suspended ceiling, lighting and HVAC systems are currently installed within the space.
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use?
414
❑ Yes
Compact: 207 Handicap: 14
0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No
If `yes , attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
la` Floor
26,882
0
0
V -B
B
1514, $
21'd Floor
28,882$a
0
0
V -B
B
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use?
414
❑ Yes
Compact: 207 Handicap: 14
0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
® Sprinklers ® Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No
If `yes , attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: Applications\Fonns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0
Signature:
A ! HOBWEDDKGENT:
Print Name: Paul Engert
Mailing Address: pengert@Imueller.com
Date: 06/03/2010
Day Telephone: (206) 325 -2553
Seattle
WA 98122
City
State
Zip
Date Application Accepted:
. O
Date Application Expires:
I�—
Staff Initials:
�
(.17
1
3 (d
H:'Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 7888900170 Permit Number: D10 -145
Address: 18200 CASCADE AV TUKW Status: APPROVED
Suite No: Applied Date: 06/03/2010
Applicant: WASHINGTON MULTI - FAMILY HOUSING Issue Date:
Receipt No.: R10 -01090
Payment Amount: $1,064.90
Initials: JEM Payment Date: 06/17/2010 02:57 PM
User ID: 1165 Balance: $0.00
Payee: ADNAN SMAJIC, SMAJIC CONSTRUCTION
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 01431G
ACCOUNT ITEM LIST:
Description
1,064.90
Account Code Current Pmts
BUILDING - NONRES 000.322.100
STATE BUILDING SURCHARGE 640.237.114
Total: $1,064.90
1,060.40
4.50
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 06 -17 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://wwwci.tulcwila.wa.us
RECEIPT
•
Parcel No.: 7888900170 Permit Number: D10-145
Address: 18200 CASCADE AV TUKW Status: PENDING
Suite No: Applied Date: 06/03/2010
Applicant: WASHINGTON MULTI - FAMILY HOUSING Issue Date:
Receipt No.: R10 -00980
Initials: WER
User ID: 1655
Payment Amount: $689.26
Payment Date: 06/03/2010 08:57 AM
Balance: $1,064.90
Payee: LANCE MEULLER ARCHITECTS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 28600 689.26
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 689.26
Total: $689.26
PAYMENT
'3ECEIVFD
doc: Receipt -06 Printed: 06 -03 -2010
INSPECTION RECORD
Retain a copy with permit
INSPECTION O. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
pro-i
Project:
{A1pr ✓7"v
Type of Inspection:
F WA L 5) , ( Li A6
Address:
/82-00 Onsce'9
'u S,
Date Called:
1
Special Instructions:
/
.C�yZ.3�C - 0 /
Date Wanted:
7- 2c--)0
a.m.
c
Requester:
Phone No:
6204,- y/5 -809-0
(Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
Insdector:
Date: f
❑ $60.00 REINSPECTION FEE RE ' UIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., , ite 100. Call to schedule reinspection.
Receipt No.:
Date:
•
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION A
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Q(4 -('1
Project
u,4- we�TLIAe Uvu4in
Type of Inspectiop:
6/42- 46,
d
1?,(16 e_456.46ke Address:
Date Calle :�S
l t
Special Instructions:
/Phone
//
Date Wanted: 1 '7 —(d
a.m.
Requester:
No: c
'2i0 6 -l-4'05
0
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
1,
Inspec>ior:
,40
Dater n r
tU
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
_
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 1`1206)431 -3670
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
Project:
W A.r� I r . J 6 ,UN
f\'���.,k
Ty a of Inspection:
A k S1 t s,'CrJ N--CAP; (i4s.1
Address:
('Qj2 OO (° 6,S 6. A D�
Date Called: k d ,
%
.'''
Special Instructions:
4a
1'/
Al
1
J
Date Wanted:
�a'•Pn*
�1J
- ►-� I d
Requester:
e -/. (/ e„ n; f- _--1 -7
Phone No:
aC) 6: ti tel — 90c v
DApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
(I 0
nit as& 4
.'''
'. & -'( 1 S 1`r' . ' c -J -J
1)0 PA(
(7) Al S
D f
k 4-0-49 L.,.) ; / .& 5 A ,.�
A t) ke
-7�
e -/. (/ e„ n; f- _--1 -7
j
i ) -
t?)
/-,a cr- -- .13(11— ichu
-`r,k e
0
-ru , ^sneC -
kfAulA 2 Aey
r S ) 9/0 Je
1
Inspect r:
Date: - Z 2- —(
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
GM
40 10 -14
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Proj ct . (
It' A . t
Type o nspecti n: •
a AA . ✓�
Addre s:
1 '1,40 a
64fc
Date Called:
"1-e-)
Special Instructions:
Ayi)(1).10
Date Wanted: !
m.
Requester:
Phone ( 0 -
l
1 7 __EN 7 o
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
rk-r-r. A
t A 6 pf , f n p
c.) -,)t..-c'sjr
"1-e-)
,V k .e,t-r-4_,6,.(
Ayi)(1).10
Inspdktor:
Date: LDS
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NUMBER
Nth" "yI 4 , rc 'UU. � .dJtla.��6aC M4LCd' . IN11 �i7
INSPECTION RECORD
Retain a copy with permit
.D 1 b
— 13
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project: y w I,6.• ,
,,,f, ., kiv-s
If/ 0$
Fire Alarm:
Type of Inspection:
'c 1 ;,,
4„/
Address: Jrzgoo.
Suite #: /(93
c c% se a dm
A ✓
S •
Contact Person:
i
Special Instructions:
Phone No.:
E'Pproved per applicable codes.
nCorrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers:
1
Fire Alarm:
Hood & Duct:
/
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
i
N.
Inspector:
ocili ‘3
1
Date: 7/25A 0P
Hrs.:
/
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
e City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
y
INSPECTION NUMBER
•
•
INSPECTION RECORD
Retain a copy with permit
1 •o•""•• . l' Jju191M'','a.r
AO- S-132.
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Project: + d4.- ,mss,,,,, ti . '
Type of Inspection:
Co..4.,.
-:4
/
Address: it z e) co CA.se epeat. 4.49.- 5
Suite #: /03
Contact Person:
"4
J,/f;
Special Instructions:
Phone No.:
2.)c- <<i9- Po
Hood & Duct:
proved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Hre Alarm:
Hood & Duct:
Monitor:
, _
Pre -Fire:
''Permits:
_
Occupancy Type:
r7
4.
-
.
�,
u
'/W ..
.a
Date: 7,012 L,/a
Hrs.:
i
Needs Shift Inspection:
Sprinklers:
Hre Alarm:
Hood & Duct:
Monitor:
, _
Pre -Fire:
''Permits:
_
Occupancy Type:
Inspector: •+ '
.3 •
•
.a
Date: 7,012 L,/a
Hrs.:
i
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of.:Tukwila'Finance Department. Call to schedule a reinspection.
Word/Inspection Record Form.Doc 1/13/0.6
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East. Tukwila, Wa. 98188 206 -575 -4407
Project: t4,43 ,.mi a
,, ..,r
1
Type of Inspection:
6 "r- A44; ....K.►
Address: /t
Suite #: /p3sL
Cdase4,416 Ale.
3.
Contact Person:
Special Instructions:
Phone No.:
3c', -- `fciI — G3Z alt
Approved per applicable codes.
Corrections reu it
.r
COMMENTS:
11'
for to approval.
5 7 ;, 5 ,h s
v >�
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
Date: ,, 3,J /A
Hrs.:
•
$80.00 REINSPECTION FEE,.REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record FOrm.DOc 1/13/06
T.F.D. Form F.P. 113
ti
INSPECTION RECORD
Retain a copy with permit •
INSPECTION NUMBER •
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project: 1 •
{_ ..
t4.0-.. 4.
Type of Inspection:
sel C60.4, ec
Address: / o
Suite #: /b3
ciii.gc ,q,c) 42_ p4aes
Contact Person:
/`Dr
Special Instructions:
Occupancy Type:
Phone No.:
nApproved• per applicable codes.
KCorrections required prior to approval.
COMMENTS:
10 Do got) a iz
c_P ,J1/4-kr v Spp L<
OK C AJ-te /► Aunt 4C( .9s -to cAe ti tigAJoick
Needs Shift Inspection:
Sprinklers:
'Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
.1/1.
5-g--
Date: 7/07040
Hrs.: x
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113 ?
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
2006 Washington State Nonresidential Energy Code Compliance Forms
LTG -INT
Project Info
Project Address Washington Nutli- Family Housing
Date 6/3/2010
18200 Cascade Ave South
For Building Department �v/
FI L p� COP S
ApFe9 ®O'
Tukwila, Washington
Applicant Name: Lance Mueller & Associates
-
c*- -t e�
Applicant Address: 130 Lakeside Ave, Seattle, Washington �� s
Applicant Phone: 206 325 -2553
Project Description
❑ Plans Included
requirements.
❑ New Building 1 Addition 4 Alteration
Refer to WSEC Section 1513 for controls and commissioning
Compliance Option
O Prescriptive O Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2 **
Area in ft2
Allowed x Area
** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
Proposed Lighting Wattage
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Interior
Total Proposed Watts
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank.
Dl0- ty5
RECEIVED
JUN 03 2010
P TC NTER
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary (back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
Q Warehouses, storage areas or aircraft storage hangers Q Other
fication
QualiQualification Checklist
answer If Is occupancy
answer Is checked, the number of fixtures in
ed type is "Other" and resin
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
(
1521)
❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
-9 Untt Lighting Power Allowance
Use
LPA` (W /sf)
Use'
LPA1(W/sf)
1.0
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools, hospitals, institutions, museums, banks,
churches)5''•"
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations"
1.0
Cafeterias, fast food establishments5,
restaurants /bars5
1.3
Post office
1.1
Dormitory
1.0
Retail70, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia", assembly spaces"
1.0
Theater, motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses ', storage areas
0.5
Hotel banquet/conference /exhibition hall'•°
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
"laboratory' shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries5
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies' (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W /ft2.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
• •
Joanna Spencer - Re: 18200 Cascade Ave S D10 -145
From: Todd Reedy
To: Joanna Spencer
Date: 06/09/2010 2:57 PM
Subject: Re: 18200 Cascade Ave S D10 -145
Hi Joanna,
Page 1 of 1
Backflow testing is current at 18200 Cascade (next tests are due Oct. 2010). If you remember this property
shares a fireline connection with 18300 Cascade and I noticed the FDC is a siamese so they need to install a
Storz adapter.
Todd
»> Joanna Spencer 06/09/2010 12:00 PM »>
Todd,
Are they current on their backflows ?
Thanks,
Joanna
file: / /C: \Documents and Settings \joanna.TUKWILA \Local Settings \Temp\XPgrpwise \4C... 06/09/2010
•
1�,r j � J3 .'�, f , 4 t
'ja ` .: x, PY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -145 DATE: 06 -03 -10
PROJECT NAME: WASHINGTON MULTI- FAMILY HOUSING
SITE ADDRESS: 18200 CASCADE AV S - SUITE 103
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
BuTdi Dlvislon
Pt(btid Wo "r'ks
011‘
Prevention Nil
to- 114- I0
Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 06-08-10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING: -61 Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 07-06-10
Approved ❑ Approved with Conditions Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pier Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name Smajic Construction Llc UBI No. 602566567
Phone 2064198090 Status Active
Address 12219 Se 65Th St License No. SMAJICL954R2
Suite /Apt. License Type Construction Contractor
City Bellevue Effective Date 12/22/2005
State Wa Expiration Date 12/22/2011
Zip 98006 Suspend Date
County King Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
Smajic, Adnan
Partner /Member
12/22/2005
Amount
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
SG4819
12/15/2005
Until Cancelled
$12,000.00
12/22/2005
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
CBIC
C11SG4819
12/15/2007
12/15/2010
$1,000,000.00
10/28/2009
1
CBIC
C11SG4819
12/15/2005
12/15/2007
$1,000,000.00
10/09/2006
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip /Print.aspx 06/17/2010
• __ -.�... xmaq
f.a"6 °4
•
i pANrt"!EK
'-- N11:019001 NC
CASCADE AVENUE SOUTH
10
BUILDING 1
18300 CASCADE AVE. SOUTH
11.
•
■ :
161c1,1 I<<�,IGJ:Fci GIG ti
c
6'
14 178'50' E 645.35' -W MINN Went
0 I
COWL NIL
ICON= 0123 --
crIcIcl{I{ c�c(G
LLJJL..
°ce6neae°u "o
BUILDING 2
18200 CASCADE AVE. S
N 128 :50" E 147.37' '
i
777"
�uu
emu■ � • b
c,
'
('}
/`C � l � IIII • ` il. � i , l l � � l � ) i � l ) I I ! I ' � I I I ! [ 1 � � � I � I � � � � N ▪ � I � � I L I -
J lG c c,
,.�.. - -� -`-� �`-
WEST VALLEY HIGHWAY
(_ SITE PLAN
/ NO SCALE
ABBREVIATIONS
LPL
•
"*.••••• z
•
I 14W
n
i 1/
C/
c
•
z
ce
c
ADJ
ALT
AFF
ALUM
L
ANOD.
ACT
BLDG.
BLK'G.
BM
B/S
CAB
CIRC
CLR
CLG
CL
COL
CONC
CONST
CONT
COORD
CPT
CT
DET
DIA
DIM
DN
DR
DWG
EA
EL
ELEC
ELEV
EN
EQ
EXIST
FE
FF
FIN
FLR
FLUOR
FOIC
ADJUSTABLE / ADJACENT
ALTERNATE
,ABOVE FINISH FLOOR
ALUMINUM
ANGLE
ANODIZED
ACOUSTICAL CEILING TILE
AT
BUILDING
BLOCKING
BEAM
BUILDING STANDARD
CABINET
CIRCULATION
CLEAR OR CLEARANCE
CEILING
CENTERLINE
COLUMN
CONCRETE
CONSTRUCTION
CONTINUOUS
COORDINATE
CARPET
CERAMIC TILE
DETAIL
DIAMETER
DIMENSION
DOWN
DOOR
DRAWING
EACH
ELEVATION
ELECTRIC
ELEVATION OR ELEVATOR
ENAMEL
EQUAL
EXISTING
FIRE EXTINGUISHER
FACTORY FINISH
FINISH
FLOOR
FLUORESCENT
FURNISHED BY OWNER
INSTALLED BY CONTRACTOR
FT
FTIC
FURN
GA
GALV
GL
GWB
HDW
HM
HGT
HVAC
IN
INCAD
INCL
INSUL
INSTL
JAN
JB
JST
JT
KIT
LF
LTG
MAT'L
MAX
MECH
MED
MEZZ
MFR
MISC
MTD
MTL
N/A
NIC
NO
NOM
NTS
FOOT / FEET
FURNISHED BY TENANT
INSTALLED BY CONTRACTOR
FURNISH / FURNISHINGS
GAUGE
GALVANIZED
GLASS 1 GLAZING
GYPSUM WALL BOARD
HARDWARE
HOLLOW METAL
HEIGHT
HEATING VENTILATING
AIR CONDITIONING
INCH
INCANDESCENT
INCLUDE
INSULATION
INSTALLATION
JANITOR
JUNCTION BOX
JOIST
JOINT
KITCHEN
LINEAL FOOT
LIGHTING
MATERIAL
MAXIMUM
MECHANICAL
MEDIUM
MEZZANINE
MANUFACTURER
MISCELLANEOUS
MOUNTED
METAL
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
OC
OPN'G
OPP
PERP
PL
PLYWD
PNL
PR
PROP
PT
R
RB
RFGR
REINF
REQ'D
REV
RM
RO
SC
SECT
SHT
SIM
SM
SQ
STD
SUSP
TELE
TEMP
THERMO
TYP
VAR
VCT
VEN
VERT
VWC
WI
W/0
WC
WD
ON CENTER
OPENING
OPPOSITE
PERPENDICULAR
PLATE OR PLASTIC LAMINATE
PLYWOOD
PANEL
PAIR
PROPERTY
PAINT
RADIUS
RESILIENT BASE
REFRIGERATOR
REINFORCEMENT
REQUIRED
REVERSE
ROOM
ROUGH OPENING
SOLID CORE
SECTION
SHEET
SIMILAR
SHEET METAL
SQUARE
STANDARD
SUSPENDED
TELEPHONE
TEMPERED
THERMOSTAT
TYPICAL
VARIES
VINYL COMPOSITION TILE
VENEER
VERTICAL
VINYL WALL COVERING
WITH
WITHOUT
WALL COVERING
WOOD
C
GENERAL NOTES
AREA OF WORK
THIS PERMIT
FIRST FLOOR
SEPARATE PERMIT
REQUIRED FOR:
Kiethanleal
eetfical
umbirq
fibae Aping
City of Tukwila
BUILDING DIVISION,
REVISIONS
No granges shall be made to the scope
of Work without prior approval of
Tukwila Building Division.
NOTE: Revisions will requite a new plan submittal
and may include additional plan review fees.
n VICINITY PLAN
NO SCALE
FILE COPY
Permit No.,1) 0 "" 140
Plan review approval is subject to errors and omissions.
/Approval of construction documents does not authorize
1h ; violation of any adopted code or ordinance. Receipt
a' approved Field ► ,y :.t:, conditions is acknowledged:
By
Date:
City Of TU to
BUILDING DIVISION
1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING
SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION.
2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL
CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND
COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS.
ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED
WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR.
3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND
MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE
AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL,
THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL
EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT
DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED
BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE
SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE
MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF
FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN
ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL
MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR
ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL
BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK,
MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY
WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL
SERVICES.
5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF
WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED.
6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME
SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL.
7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER
THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN
PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL CONTRACTOR SHALL PROVIDE
SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECTS APPROVAL ON ALL SPECIAL
ITEMS REQUIRING CUSTOM FABRICATION.
8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY
ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS.
9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR
ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE
DRAWINGS.
10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE,
COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS
PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE.
D OTHERWISE.
11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE
REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES,
SUBJECT TO ARCHITECTS APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL
REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH
RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF
INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT
AND OWNER PRIOR TO INSTALLATION.
12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED
OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS
NOTED OTHERWISE.
13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL
REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH
EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS,
WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF
EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS
SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN
THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED.
14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS
BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE
WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS
SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY
REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT
MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT
SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR
PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO
SUBSTITUTE WILL BE ACCEPTED.
15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE
WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS.
16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE
ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND
ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY
OTHERS.
17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL
SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND
SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE
CABINETS ETC.
18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL
OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT.
19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4" IN 10 " -0 ". THE
CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT
MEET THIS STANDARD.
20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED
OTHERWISE.
tenant improvement
Washington
Multi-Family Housing
18200 Cascade Avenue South
Tukwila,WA
PROJECT NOTES
TAX LOT NUMBER: 7888900170
LEGAL DESCRIPTION:
SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S
78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A
LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N lld 23'
50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11°
2T 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A
OF 62D 57' 52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF &
PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN
SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44°
29' 00" E 96.32 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET S 82° 08' 00 "E 100.00
FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M/U TO W/
MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF
GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33'
20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51° 37'
10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.14 FEET
ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEET THEN N
78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE II OF CORPORATE PROPERTY INVESTORS
BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA
BOUNDARY LINE.
ZONE:
SITE AREA:
CONSTRUCTION TYPE:
BUILDING AREA:
NORTH BUILDING
NO. STORIES
SOUTH BUILDING
NO. STORIES
PARKING REQUIRED:
PARKING PROVIDED:
CODES USED:
TENANT AREA:
OCCUPANCY:
OCCUPANT LOAD:
TENANT:
SCOPE OF WORK:
C / CU
6.58 ACRES
V -B FIRE SPRINKLERED
53,625
2
53,625
2
278 STALLS
414 STALLS
2006 INTERNATIONAL BUILDING CODE
2006 INTERNATIONALFIRE CODE
2006 WASHINGTON STATE ENERGY CODE
2006 WASHINGTON STATE BUILDING CODE
2006 PLUMBING CODE
2006 MECHANICAL CODE
2003 ANSI A117.1 ACCESSIBLE AND
USEABLE BUILDINGS AND FACILITIES
1,582 USEABLE SQ. FT. (FIRST FLOOR)
B - OFFICE
100 SQ. FT. /OCCP. 1,582/100 = 16 OCCUPANTS
WASHINGTON MULTI - FAMILY HOUSING
INTERIOR TENANT IMPROVEMENT ON THE FIRST FLOOR OF APPROXIMATELY
1,582 SQ. FT. THE WORK CONSISTS OF BUILDING NEW OFFICES, DOORS AND
MULTI - PURPOSE -ROOM. THE SPACE CURRENTLY HAS A COMPETE SUSPENDED
ACOUSTICAL TILE CEILING AND LIGHTING SYSTEM. A PORTION OF EXISTING
LIGHT FIXTURES WILL BE RELOCATED: THE SPACE WILL BE ACCESSED BY
MEANS FOR AN EXISTING NON -RATED HALLWAY.
BUILDING
REPRESENTATIVE:
ARCHITECT:
GENERAL
CONTRACTOR:
O'KEEFE DEVELOPMENT COMPANY
1100 OLIVE WAY, SUITE 400
SEATTLE, WA 98101
T. (206) 236 -6200 F. (206) 236 -6160
CONTACT: HARPUR DAVIDSON
EMAIL: harpur @okeefedevelopment.com
LANCE MUELLER & ASSOCIATES
130 LAKESIDE AVE
SEATTLE, WA 98122
T. (206) 325 -2553 F. (206) 328 -0554
CONTACT: PAUL ENGERT
EMAIL: pengert @Imueller.com
SMAJIC CONSTRUCTION, LLC
12219 SE 65th STREET
BELLEVUE, WA 98006 '
T. (206) 419 -8090 F. (425) 378 -2593
CONTACT: ADI SMAJIC
EMAIL: smajic @msn.com
DEFERRED SUBMITTALS
1. PLUMBING WORK UNDER SEPARATE PERMIT
2. MECHANICAL WORK UNDER SEPARATE PERMIT
3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT
INDEX OF DRAWINGS
TAI.1
TA2.1
TA2.2
TA2.3
TA3.1
TA3.2
■
COVER SHEET / SITE PLAN
1/16" OVERALL BUILDING PLANS
1/8" SECOND DEMO. / FLOOR PLANS
1/8" SECOND CEILING PLAN
WALL SECTIONS / CEILING DETAILS
DOOR SCHEDULE / INTERIOR ELEVATIONS / DETAILS
b1O
ICE
REVIEWED
FOCODECOMPL IA
AM 17 MO
City of Tukwi a
BUILDING Divigirnl
RECEIVED
JUN 03 2010
PERMIT CENTER
ys
I=
_
uJ
Lw
0
0 rn
ru J
uJ
w
J
1
w
3
Z
J
0.
w
Cn
w J
W sheet
U)
cc
U 0
TA
1.1
MIA
(2 06) 325 -2553
l-°
N
N
w
H
ul
I•
w
0
U u,
w
- J
0
Q m
CO
•
M
Co
i-.0_
Q)
17
'd
PERMIT SUBMITTAL 1
0
0
N
0
10 -050
job no.
P. ENGERT
drawn
P. ENGERT
checked
05 -28 -10
date
I=
_
uJ
Lw
0
0 rn
ru J
uJ
w
J
1
w
3
Z
J
0.
w
Cn
w J
W sheet
U)
cc
U 0
TA
1.1
MIA
(2 06) 325 -2553
l-°
N
N
w
H
ul
I•
w
0
U u,
w
- J
0
Q m
,000
0
LGOCKDj
EGRESS PATHWAY
77-7
iy FLOOR -2 OVERALL PLAN
\ 1116" =1' -0"
9
J
J
0
77-0'
77-0'
EGRESS PATHWAY
A 0
EGRESS PATHWAY
-E1J-- -i
22-11'
?7.10'
71'•10'
22.10'
77.1P
27-10.
72.11'
N
m
10747
. v.-,
C
0
.y
'S
N
,....■
...t
EXIT
77-0'
77.0'
AREA OF WORK
THIS PERMIT
77-0`
COMMON PATH OF
TRAVEL = 50' /
e/
(_ 3FLOOR -1 OVERALL PLAN
1/16" =1' -0"
REVIEWED FOR
CODE COMPLIANCE
AP'RnvEn
JUN 17 21110
City of Tukwila
BUILDING nivimm
RECEIVED
JUN 0 3 2010
PERMIT CENTER
o
w
cc
V
w
CD
cc
,_
O
D)
E m
ca
lam z
�.r
L
G
0 co
w_
a OEQ�
w
U
0
UJ N
N
Q�
3
� Q
W wN
z J
`J J �-
o_ Fin
N W
w
w
• e
I •
W
Z Z Et ;
0 Q
J J J a m
m sheet
(206)
0
TA2.1
06/03 /08 •
N
m
PERMIT SUBMITTAL
C
0
.y
'S
N
O
C
•ou qof
050-0I.
P. ENGERT
drawn
_P.ENGERT
checked
0
�1
) `6
-o
o
w
cc
V
w
CD
cc
,_
O
D)
E m
ca
lam z
�.r
L
G
0 co
w_
a OEQ�
w
U
0
UJ N
N
Q�
3
� Q
W wN
z J
`J J �-
o_ Fin
N W
w
w
• e
I •
W
Z Z Et ;
0 Q
J J J a m
m sheet
(206)
0
TA2.1
C15
22' -U"
22' -0"
11
4
N
4
(_ FLOOR -1 DEMO. PLAN
�� 118" =1' -O"
FLOOR DEMO. KEYNOTES
1. OPENING IN EXIST. WALL FOR NEW DOOR AND SIDELIGHT.
DEMOLITION SYMBOLS & LEGEND
EXISTING WALL TO BE REMOVED
EXISTING WALL TO REMAIN
12) (13
17E
' -O"
22' -0"
22' -O"
22' -0"
221 -0"
22' -0"
22' -0"
22' -U"
1
1
10
x
WOMEN'S
r3
0
WOMEN'S
SHOWERS
11
MEN'S
SHOWERS
HALLWAY
FITNESS
CENTER
LEASE
SPACE
N
ARCHITECTURAL SYMBOLS & LEGEND
EXISTING WALL TO REMAIN
NEW WALL PER PLAN
NEW WALL W/ SOUND INSULATION PER PLAN
DOOR NUMBER
EX. = EXIST DOOR TO REMAIN
ELEVATION LETTER
ELEVATION NUMBER
INTERIOR ELEVATION SYMBOL
SHEET NUMBER
OFC.
(105)
FEC
0
ROOM NAME & NUMBER
WALL TYPE REFERENCE
DETAIL NUMBER
DETAIL REFERENCE
SHEET NUMBER
DETAIL NUMBER
SECTION REFERENCE
SHEET NUMBER
SEMI - RECESSED FIRE EXTINGUISHER CABINET
SURFACE MOUNTED FIRE EXTINGUISHER
19' -0"
6' -0" 3' -0"
4'-10"
"
UP
0
STORAGE
(102)
- +42'
r-1
LI
0
101
1
+42"
Q4
107
MULTIPURPOSE
ROOM
(103)
26' -0"
ELECTRICAL SYMBOLS & LEGEND
CV
m
0
10"
ALIGN
106
OFC.
105
EQ. EQ.
ELECTRICAL OUTLETS, LIGHTING AND SWITCHING SHOWN FOR GENERAL
DESIGN INTENT. ELECTRICAL CONTRACTOR TO CONFIRM ELECTRICAL
REQUIREMENTS WITH TENANT PRIOR TO ANY WORK.
dIMER
DUPLEX ELECTRICAL OUTLET 110V
DEDICATED DUPLEX ELECTRICAL OUTLET 110V
FOURPLEX ELECTRICAL OUTLET 110V
DEDICATED FOURPLEX ELECTRICAL OUTLET 110V
TELEPHONE /DATA OUTLET
ELECTRICAL OUTLET W/ TIMER
FLUSH FLOOR ELEC. / DATA BOX
ELECTRICAL JUNCTION BOX
SYSTEM FURNITURE POWER POLE LOCATION
(CONFIRM W/ FURNITURE VENDOR)
SYSTEM FURNITURE BASE POWER FEED
(CONFIRM W/ FURNITURE VENDOR)
101 -0" 12'-4"
N
CV
4
co
() FLOOR -1 FLOOR PLAN
`� 118" = l' -0"
FLOOR PLAN KEYNOTES
1. CENTER DOOR IN WALL.
2. ALL FURNISHINGS BY TENANT.
3. SEMI - RECESSED FIRE EXTINGUISHER CABINET. SEE DETAIL 20 / TA3.2
4. BUILT -IN UPPER & LOWER PLASTIC LAMINATE CASEWORK.
REVIEWED FOR
CODE COMPLIANCE
JUN 17 211itl
City of Tukwila
BUILDING nhUi inn,
RECEIVED
JUN 03 2010
PERMIT CENTER
cu
E
0
E
c
1=
0
old
Imo
cgs
1
D)
m
0
Z
C�
CV
V �
2 w c
o Q
a C
O v as
co
'o U c
BOO •
[7
N N
CO
a
0
Wcn
sheet
TA2.2
06103/08__
0
m
v
PERMIT SUBMITTAL
c
0
'5
0
c
'au qof
090-01,
P. ENGERT
drawn
P. ENGERT
checked
0
;TS
cii
o
m
f°
-o
cu
E
0
E
c
1=
0
old
Imo
cgs
1
D)
m
0
Z
C�
CV
V �
2 w c
o Q
a C
O v as
co
'o U c
BOO •
[7
N N
CO
a
0
Wcn
sheet
TA2.2
1
I NMI
MIDI A
j I
ILusim■
ilak.
H1*1lli 1
CEILING / LIGHTING SYMBOLS
f
0
r
la
EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE
CEILING AND GRID SYSTEM
EXISTING GWB CEILING
EXISTING 2' x 4' BLDG. STD FLUORSCENT LIGHT
FIXTURE
EXISTING RECESSED COMPACT FLUORESCENT
HALLWAY LIGHT FIXTURE
EXISTING LIGHTED EXIT SIGN
(CM = CEILING MOUNT WM = WALL MOUNT)
EXISTING 2' x 4' BLDG. STD FLUORESCENT LIGHT
FIXTURE TO BE REMOVED OR RELOCATED
NEW OR RELOCATED 2' x 4' BLDG. STD
FLUORSCENT LIGHT FIXTURE
NEW LIGHTED EXIT SIGN
(CM = CEILING MOUNT WM = WALL MOUNT)
NEW DIRECTIONAL LIGHTED EXIT SIGN
(CM = CEILING MOUNT WM = WALL MOUNT)
EMERGENCY EGRESS PATHWAY LIGHT FIXTURE
(MIN. LIGHTING LEVEL IS 1 FOOTCANDLE AT + 3' -O"
FROM FINISH FLOOR MAINTAINED)
FLOOR -2 CEILING PLAN
1/8" = 1'-0"
GENERAL NOTES
1. ELECTRICAL CONTRACTOR SHALL INSTALL EMERGENCY EGRESS
LIGHTING WITHIN TENANT SPACE TO PROVIDE A MINIMUM OF 1
FOOTCANDLE AT THE WALKING SURFACE. THIS IS IN ACCORDANCE
WITH IBC SECTION 1006. ELECTRICAL CONTRACTOR SHALL MEASURE
LIGHTING LEVELS ALONG THE COMMON PATH OF EGRESS TO MAINTAIN
THE 1 FOOTCANDLE MINIMUM LEVEL TO THE EXIT DISCHARGE. THE
EMERGENCY LIGHTING SHALL BE INSTALLED ALONG THE "COMMON
PATH OF TRAVEL" SEE SHEET TA2.1 FOR LOCATION
2. SUSPENDED CEILING SYSTEM IS EXISTING THROUGHOUT THE SPACE.
SEE SHEET TA3.1 FOR NOTES REGARDING ANY CHANGES OR
ALTERATIONS TO SYSTEM.
KEYNOTES
1. EXIST. LIGHT FIXTURE TO BE RELOCATED.
REVIEWED FOR -
CODE COMPLIANCE
Apps - nvEn
JUN 17 2010
City of Tukwfla
BUILDING flI II 1nrg
RECEIVED
JUN 03 2010
PERMIT CENTER
w
w iL
N
w
w CD
cc
CA
O
1
ii.
num
m
sop
o wig
2
g-
co
co
13
0
D)
cts
206) 325 -2553
I
w
0
0 U
w
J
0
Q m
sheet
TA2.3
06/03/08 •
0
m
v
PERMIT SUBMITTAL
c
0
.y
'5
t_
c
c
10-050
job no.
P. ENGERT
drawn
_P.ENGERT
checked
0
r-
eb
a A
o `O
v
w
w iL
N
w
w CD
cc
CA
O
1
ii.
num
m
sop
o wig
2
g-
co
co
13
0
D)
cts
206) 325 -2553
I
w
0
0 U
w
J
0
Q m
sheet
TA2.3
IF HANGER WIRE IS OUT
OF PLUMB GREATER THAN 1:6
COUNTER SPLAY PER ASTM C636
WALL WHICH
PENETRATES
CEILING GRID
WALL EDGE
MOLDING
MAX. 8"
MIN. 2"
MIN. 3/4" @
UN- ATTACHED WALLS
EDGE BRACING
CEILING SEISMIC BRACING
#12 PERIMETER HANGER WIRE
ANCHORED TO STRUCTURE ABOVE @
EACH MAIN BEAM OR CROSS TEE
STABILIZER BAR SYSTEM TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART @ UNATTACHED
WALLS ONLY
TIGHT LOOP THROUGH HANGER HOLE
& THREE TIGHT TURNS WITHIN 3" (
TOP TO BOTTOM)
PER ASTM C636
MAIN BEAM OR CROSS TEE
CEILING GRID
#12 HANGER WIRE
ANCHORED TO —
STRUCTURE ABOVE
MAIN BEAM
ood
SEISMIC JOINT CLIP
EXPANSION SLEEVE
CEILING EXPANSION JOINT
WALL EDGE
MOLDING
CROSS TEE
PER ASTM C635
STABILIZER BAR SYSTEM TO KEEP
PERIMETER COMPONENTS FROM
SPREADING APART @ UNATTACHED
WALLS ONLY
EDGE BRACING ISOMETRIC
X55
kA
STEEL STUD COMPRESSION POST
ONLY IF REQUIRED BY
AUTHORITY HAVING JURISDICTION
#12 HANGER WIRE TYP.
TIGHT LOOP THROUGH
HANGER HOLE & THREE
TIGHT TURNS WITHIN 3" (
TOP TO BOTTOM)
O o
O
CROSS TEE
PER ASTM C635
MAIN CEILING
BEAM PER ASTM C635
CEILING GRID SEISMIC BRACING
NO SCALE
SUSPENDED CEILING ARE TO COMPLY WITH THE
FOLLOWING CODES AND REGULATIONS:
A. 2006 INTERNATIONAL BUILDING CODE (IBC) SECTION 803.9
B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C635 AND ASTM C636
(REFERENCED IN IN 803.9).
C. ASCE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 7 SECTION 9.6.2.6
D. CISCA (CEILING & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) RECOMMENDATIONS
FOR SEISMIC ZONES 3-4 REFERENCED IN ASCE - 7 SECTION 9.6.2.6.2.2
E. IBC 102.1 STATES "WHERE IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE
SPECIFY DIFFERENT MATERIALS, = METHODS OF CONSTRUCTION OR OTHER
REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC
REQUIREMENT SHALL BE APPLICABLE ".
F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS:
• ONLY A HEAVY DUTY T -BAR GRID SYSTEM SHALL BE USED. ASTM - 7 SECTION
9.6.2.6.2.ITEM A.
• WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE ) SHALL BE NOT
LESS THAN 2 INCHES. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM B.
• ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP
RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A34" INCH
CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASTM -7 SECTION
• STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND OR
CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG
SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION
SECTION, ITEM 4.
• PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR
ALL EDGES . CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED
CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4.
• VERTICAL HANGERS SHALL BE NO. 12 GAGE WIRE SPACED AT 4' -0" ON CENTER OR NO. 10
GAGE WIRE SPACED AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE
TURNS REQUIRED WITHIN 1 :6 OUT -OF -PLUMB UNLESS COUNTER - SLOPING WIRES ARE
PROVIDED.
• LATERAL BRACING IS REQUIRED. SPLAY WIRES PODS AT 12" MAX. O.C. AND 6' -0" MAX. FROM
WALLS. INSTALL TRULY COMPRESSIBLE (E.G. SPRING LOADED) STRUTS OR NO STRUTS
AT ALL. RIGID STRUTSARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR
DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004,
INSTALLATION SECTION, ITEM 3.
• CEILINGS OVER 2500 SQ . FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL
HEIGHT WALLS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQ. FT.
ASTM - 7 SECTION 9.6.2.6.2.2 ITEM D.
• FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS
SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OF ADAPTER THROUGH THE CEILING TILE TO
ALLOW FOR FREE MOVEMENT OF A LEAST 1 INCH IN ALL DIRECTIONS; OR SPRINKLER HEAD
EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING
MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM E.
• CHANGES IN CEILING PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING.
ASTM - 7 SECTION 9.6.2.6.2.2 ITEM F.
• CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUSPENDED INDEPENDENTLY FROM
THE CEILING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM G.
X10-145
ATTACH 2 Yz" x 20 GA.
METAL STUDS BRACES
TO TOP TRACK W/ (2) -
METAL FRAMING
SCREWS
R
CODEpCOMPLIANCE
Ato ma)
2Y" x 20 GA. METAL STUDS BRACES @
8' -0" O.C. (ALTERNATE DIRECTIONS) AT
ALL WALL LOCATIONS OVER 12' -0" LONG.
ATTACHED TO WOOD FLOOR STRUCTURE
ABOVE
rn
;4
.
.•
.4 .4
Pr
o
.
.
.;
.4
le
I,
MAKE N(
WALL TC
SYSTEM
EXIST. A
CEILING
2Yz" SOU
FLOOR P
2Y "x251
24" O.C.1
EACH SI[
Ye" DIA. P
FASTENE
RUBBE
EXIST. C(
••
IN
►1
'4!
or
o :
.4
►'
4
41
.1,
4
•
.4
.•
•4,
Pr
;,
•
•'
:1
.3
.4
•.
.
o
o
co
v
GRADE
--
d..
. .• 4.
11- n i-iii
c
0
J jii i 7 2010
City of Tukwila
BUITYP.OFFI PARTITION
1 /2" = 1' -0"
ATTACHMENT OF
CEILING GRID
OUSTICAL TILE
ND INSULATION PER
LAN
A. METAL STUDS @
JITH 5/" TYPE "X" GWB
E
WDER ACTUATED
RS @ 24" O.C. TYP.
R BASE
NCRETE SLAB ON
RECEIVED
JUN 03 2010
PERMIT CENTER
w
3
m
•
CC
IWO
1i
1
U �
a)
a `�<v,
>'-°',c
U v
EL ■t
c y 'Q v `a
co C O
> CV
C))
Ca
c
0
Z
325 -2553
t0
0
sheet
TA3.1
06/03/08 1
o
co
v
PERMIT SUBMITTAL
c
0
d
c
10 o
C
1- o
P. ENGERT
drawn
_ P. ENGERT
checked
0
c
N
o
N
w
3
m
•
CC
IWO
1i
1
U �
a)
a `�<v,
>'-°',c
U v
EL ■t
c y 'Q v `a
co C O
> CV
C))
Ca
c
0
Z
325 -2553
t0
0
sheet
TA3.1
WEST
STORAGE #103
1/4" =1' -0"
7.4
ANGLED
0
0
WEST
WORK #107
CV
N
ANGLED
NORTH
114" =1' -0"
12
CASEWORK KEYNOTES
NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE
CABINETS
NOTE 2. - 12" DEEP UPPER PLASTIC
LAMINATE CABINETS
NOTE 3. - PLASTIC LAMINATE COUNTERTOP
AND 4" HIGH BACK SPLASH
NOTE 4. MICROWAVE SHELF
NOTE 5. - REFRIGERATOR
ALL APPLIANCES TO BE FURNISHED AND
INSTALLED BY TENANT
13 5/8"
(4
T
CV
PLASTIC LAMINATE UPPER
CABINET W/ 2 ADJUSTABLE
SHELVES. ALL INTERIOR
SURFACES TO BE FINISHED
W/ WHITE MELAMINE
4" WIRE PULL TYP.
PLASTIC LAMINATE
BACKSPLASH &
COUNTERTOP
CASEWORK SECTION
DRAWER W/ WIRE PULL
PLASTIC LAMINATE BASE
CABINET W/ ADJUSTABLE
SHELVE. ALL INTERIOR
SURFACES TO BE FINISHED
W/ WHITE MELAMINE
BASE PER SCHEDULE
1" =1' -0"
WALL CONSTRUCTION PER
FLOOR PLAN
1" DBL. FACED GLAZING TAPE
.050 ALUM. BREAK SHAPE TO MATCH
EXISTING STOREFRONT MAKE NO
PHYSICAL CONNECTION TO
STOREFRONT
.050 ALUM. BREAK SHAPE TO
MATCH EXISTING VERT. MULLION
EXISTING STOREFRONT
SYSTEM
WALL @ FALSE MULLION
3" =1' -0"
DOOR SCHEDULE
i
/
] \l
/
\ly/
n
\
/"N
/
N
HARDWARE
GROUP
/N
/
REMARKS
N
7
MAT.
\I
I/z
NORTH
114" =1' -0"
12
CASEWORK KEYNOTES
NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE
CABINETS
NOTE 2. - 12" DEEP UPPER PLASTIC
LAMINATE CABINETS
NOTE 3. - PLASTIC LAMINATE COUNTERTOP
AND 4" HIGH BACK SPLASH
NOTE 4. MICROWAVE SHELF
NOTE 5. - REFRIGERATOR
ALL APPLIANCES TO BE FURNISHED AND
INSTALLED BY TENANT
13 5/8"
(4
T
CV
PLASTIC LAMINATE UPPER
CABINET W/ 2 ADJUSTABLE
SHELVES. ALL INTERIOR
SURFACES TO BE FINISHED
W/ WHITE MELAMINE
4" WIRE PULL TYP.
PLASTIC LAMINATE
BACKSPLASH &
COUNTERTOP
CASEWORK SECTION
DRAWER W/ WIRE PULL
PLASTIC LAMINATE BASE
CABINET W/ ADJUSTABLE
SHELVE. ALL INTERIOR
SURFACES TO BE FINISHED
W/ WHITE MELAMINE
BASE PER SCHEDULE
1" =1' -0"
WALL CONSTRUCTION PER
FLOOR PLAN
1" DBL. FACED GLAZING TAPE
.050 ALUM. BREAK SHAPE TO MATCH
EXISTING STOREFRONT MAKE NO
PHYSICAL CONNECTION TO
STOREFRONT
.050 ALUM. BREAK SHAPE TO
MATCH EXISTING VERT. MULLION
EXISTING STOREFRONT
SYSTEM
WALL @ FALSE MULLION
3" =1' -0"
DOOR SCHEDULE
DOOR
NO.
T
P
E
DESCRIPTION
DOOR
FRAME
HARDWARE
GROUP
RATING
REMARKS
MAT.
FIN.
MAT.
FIN.
101
A
3'-0 "x8-0"
WOOD
BLDG. STD.
H.M.
PAINT
1
18" GLASS SIDELITE
102A
C
3' -0" X 7-0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
102B
B
3' -0" X 7' -0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
•
103A
C
3' -0" X 7' -0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
-
103B
C
3' -0" X 4'-0" RELITE
WOOD
BLDG. STD.
_
-
104A
B
3' -0" X 7' -0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
-
104B
C
3' -0" X 4' -0" RELITE
WOOD
BLDG. STD.
-
-
105
B
3' -0" X 7' -0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
---
106
B
3' -0" X 7 -0"
WOOD
BLDG. STD.
WOOD
BLDG. STD.
2
DOOR / RELITE TYPES
3' -0" ,,.1' -6"
SOLID CORE WOOD
DOOR
(MATCH EXISTING
SPECIES AND FINISH)
MATCH EXISTING BLDG.
STD. HOLLOW METAL
FRAME
1/4" TEMPERED
GLASS
3' -0"
WOOD DOOR &
FRAME (MATCH
EXISTING SPECIE
AND FINISH)
2' -8"
4
X" TEMPERED
GLASS
WOOD SUITE ENTRY DOOR
& HOLLOW METAL FRAME
W/ SIDELITE
HARDWARE GROUPS
WOOD DOOR & WOOD
FRAME
1. LEVER LOCK SET
(SUITE ENTRY FUNCTION)
HINGES
SILENCERS
CLOSER
WALL STOP
2. LEVER LATCHSET
HINGES
WALL STOP
19
WALL CONSTRUCTION PER
FLOOR PLAN
1" DBL. FACED GLAZING TAPE
.050 ALUM. BREAK SHAPE TO MATCH
EXISTING STOREFRONT MAKE NO
PHYSICAL CONNECTION TO
STOREFRONT
EXISTING VERT. MULLION
EXISTING STOREFRONT
SYSTEM
WALL @ VERT. MULLION
3" =1' -0"
WOOD FRAME RELITE
I v•k 1 Li 5
WALL CONSTRUCTION
PER FLOOR PLAN
— REVIEWED FOR
CODE COMPLIANCE
A. ra QED
JUId 17 2010
City of Tukwila
UILDING nil/1m m
i
n
SEMI - RECESSED
FIRE EXTINGUISHER
CABINET
RECEIVED
20 J SEMI - RECESSED FIRE CABINET JUN 03 2010
3" =1' -0" PERMIT CENTER
0
'5
C
E
O
E
c
1
gin
CO
z
sheet
TA3.2