Loading...
HomeMy WebLinkAboutPermit D10-160 - REISCHLING PRESS INC - STORAGE RACKSREISCHILING PRESS 3325 S 116 ST D10 -160 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 0923049068 Address: 3325 S 116 ST TUKW Suite No: Project Name: REISCHLING PRESS INC DEVELOPMENT PERMIT Permit Number: D10 -160 Issue Date: 07/27/2010 Permit Expires On: 06/07/2011 Owner: Name: RREEF AMERICA REIT II Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: RICHARD BALDWIN Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 206 679 -3172 Phone: 206 763 -1744 Expiration Date: 01/06/2012 DESCRIPTION OF WORK: INSTALLATION OF PALLET RACKING. RACKING TO SUPPORT CHILLERS AND HEAT REMOVAL HOOD. Value of Construction: $0.00 Fees Collected: $108.45 Type of Fire Protection: SPRINKERS /AFA International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N doc: IBC -7/10 D10 -160 Printed: 12 -14 -2010 Permit Center Authorized Signature: • Date: 6 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 11W./. Date: /011//-L// /1L� /0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D10 -160 Printed: 12 -14 -2010 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 1 c 7 7n 1z Suite No: Project Name: REISCHLING PRESS INC DEVELOPMENT PERMIT Permit Number: D10 -160 Issue Date: 07/27/2010 Permit Expires On: 01/23/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: RICHARD BALDWIN Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 206 679 -3172 Phone: 206 763 -1744 Expiration Date: 01/06/2012 DESCRIPTION OF WORK: INSTALLATION OF PALLET RACKING. RACKING TO SUPPORT CHILLERS AND HEAT REMOVAL HOOD. Value of Construction: $0.00 Fees Collected: $108.45 Type of Fire Protection: SPRINKERS /AFA International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0011 * *continued on next page ** doc: IBC -10/06 D10 -160 Printed: 07 -27 -2010 City aikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: Issue Date: Permit Expires On: D10 -160 07/27/2010 01/23/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Volumes: Cut 0 c.y. Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: I hereby certify that I have read and e governing this work will be complied Public: Non - Profit: N Public: Date: V I \Z 1 kv ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pres construction or th r .rmance of work. Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. /1 Brooks Date: ?/2--7/� U This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -160 Printed: 07 -27 -2010 • nCity of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: Suite No: Tenant: 1331L6.1269 PL TUKW REISCHLING PRESS INC PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10 -160 ISSUED 06/18/2010 07/27/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 D10 -160 Printed: 07 -27 -2010 � f City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htqx//www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: wa- Bracts Date: 2/2 77—,A) ordinances governing or local laws regulating doc: Cond -10/06 D10 -160 Printed: 07 -27 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htlp://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) VW: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: I O .).30L/- 9.06 Site Address: 3/1 S /h 0 Suite Number: 16 0 Floor: Tenant Name: R2 (IA Preff, C Property Owners Name: T O/, n _Co A e h J �/ Mailing Address: i a�,�O / t.t,/!wt'(q Jr.io1 h4 1 o,ta% /yak L r Tut t`ct , 4/4 9R i City State Zip New Tenant: ❑ Yes 12o CONTACT PERSON — ho do we contact when your permit is ready to be issued Name: g l C %A4 156,IIX ctwou Day Telephone: .204— 'V'1— 3(72. Mailing Address: 7. S. kenir St S IC w� 9g /or (lc kart "'2Vejrc.e ri✓LC.Cow E -Mail Address: City State Zip Fax Number: .2 6- 74.3- 2381 GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Reco d Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD— All plans must be wet stamped by Engineer of Record Company Name: RO,C.k �� s h Co. vS1`iuZe Mailing Address: 14 ( U- r -occl/ �Y 6j- -Leah. //-- City State Zip Contact Person: G--4r1 ��'t Cc t✓i Day Telephone: gig :Yc) 1970 Fax Number: g mil® -)g/3 GA 9 /02vY E -Mail Address: H.Applications\Forms- Applications On Line\2009 Applications11-2009 - Permit Application.doc Revised: 1.2009 bh Page 1 of 6 BUILDING PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ �"/�9OQ O JJ-- Existing Building Valuation: $ Scope of Work (please provide detailed _ inforrLmation): ZA S k /f a77 u n z) r ra te.. fr .S yDr S LA: /(e/ 4 IQs /2/ f�M'v+cti �t� 1De • 1 Ice $c ( c t !lTC Li.� 42 /.�s+er tru l/ {id'0. r /moo S S! V kr-le n � P.I..... fife- KGiei 7�/� p r`r pt�` okimitt . ✓ Will there be new rack storage? [es ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1St Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Floor Floor Floor Floors Basement Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ("No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets, SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsWorms- Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ��--� Print Name: UC7,f l / A' / yarcf Mailing Address: 72.7 J0 - yon 9- Day Telephone: Date: V .../ g--g) 2,06-- 763 -/7(y City State Zip Date Application Accepted: 0(1 ^ Y Date Application Expires: lZ4 L 1p Staff Initials:4 Ar"--- H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 • n �J,���A w4� City of Tukwila of ` :�y Department of Community Development G1 6300 Southcenter Boulevard, Suite #100 a 0 Tukwila, Washington 98188 �J± 2 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 I90a'�� Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: REISCHLING PRESS INC RECEIPT Permit Number: D10 -160 Status: APPROVED Applied Date: 06/18/2010 Issue Date: Receipt No.: R10 -01417 Initials: User ID: Payee: JEM 1165 Payment Amount: $67.50 Payment Date: 07/27/2010 11:25 AM Balance: $0.00 EVERGREEN REFRIGERATION, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 004372 67.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 63.00 640.237.114 4.50 Total: $67.50 PAYMENT DECEIVED doc: Receiot -06 Printed: 07 -27 -2010 COP of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 06 -18 -2010 at 09:46:21 06/18/2010 RECEIPT NO: R10 -01093 Initials: JEM Payment Date: 06/18/2010 User ID: 1165 Total Payment: 183.32 Payee: EVERGREEN REFRIGERATION, LLC SET ID: 0618 SET NAME: EVERGREEN REFRIGERATION SET TRANSACTIONS: Set Member D10 -160 M10 -079 M10 -080 TOTAL: Amount 40.95 52.81 89.56 89.56 TRANSACTION LIST: Type Method Description Amount Payment Check 004358 183.32 TOTAL: 183.32 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 TOTAL: 183.32 183.32 PAYMENT RECEIVED INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITIY1OF TUKWILA BUILDING DIVISION • 6300 Southcdnter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 f Permit Inspeition Request Line (206) 431-2451 1.310-ibia Project: / • le7-64S*-0.9.4dAt6 PAI4c. Type of Inspection: rot A fig i Address: - ,n /16 Date Called: .:_.p.r.s• Special Instructions: Instructions: 4 Pr. . • - . g • , ---% e, 116-..n4-e) t Date Wanted: • I ,.- 2 (e, — / / . p.m. Requester: . Phone' No: ft/06 t55-/-5 i•-?' 7 Approved per applicAle codes. Corrections required prior to approval: I e 3 t) • 41" COMMENTS: aC311414.1-104d474 Date: -74-- / ri R SPE ION FE REQUI VI Prior to ext inspection. fe must be p id at 6.00 Southcenter Blvd.NSuite 100 Call to.schedule reinspection. =Vv.. • .' INSPECTION RECORD Retain a copy .with permit INSPECTION Na PERMIT NO.R. ..CITYOF-TUKWILA.BUILDING DIVISION. • Lid -itJ • 6300 Southcenter BlVd.,.#100, Tukwila, WA 98188 (206) 431-367.0 if Permit Inspection Request Line (206) 431-2451 Project' Pr-- . 'cr Type ofpectio .A., R-47 1,...• i _ 1'17 Address:. . / It Date Ca ed: r'Speci1 Instructions: - Date Wanted: _I "."-4--. --14 Requester: Phone • Approved per applicable codes:. • _ _ COMMENTS: orrections required prior.to,approval. . reill )J ,&p vv Lk A _ ,• E tk Date: 1-7 A, 3, ION FEE REQUIRED. Pi9r to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. •••••••":4" " • v"... • ‘; e Material Handling Experts FILE COPY Permit No., 1100 SW 7th St Renton, WA 98055 (425) 255 -0500 ph (425) 228 -6946 fax ATTENTION FIRE AND BUILDING DEPARTMENTS RACK INFORMATION SUPPLEMENT _ SITE ADDRESS: 3311 S. 120th Place Ste 160 TENANT NAME: Reischling Press, Inc. DATE: June 10, 2010 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack configuration drawings attached. REVIEWED FOR CODE COMPLIANCE APPMVED JUL 0 8 2010 City of Tukwila BUILDING DIVISION 2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Racks to support Mechanical Blower and sheet metal hood assembly which provides circulated air to cool industrial printers. Blower assembly weighs approximately 600 lbs. 6. Sprinkler System Information: .39 gallons per minute over 5600 square feet. 2289 gallons per minute at 63.03 psi with 360 heads. 7. Smoke and heat vents: In place, but not required for square footage of racking (+'EIVED_ 12,000 square feet). CITYoFTU I.A 8. Building egress and exits indicated on attached drawings. JUN 18 2010 PERMIT CENTER TA°H(f(3 BY G. OHANIAN DATE 6 -5 -10 SUBJECT RAdK DEOI(4N & EN(INEERIN(t do. 412 WET BROADWAY, BUTTE #204 CLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 1 JOB NO RD -14858 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FELE COPY Permit No. REISCHLING PRESS INC. 3311 SOUTH 120th PLACE, SUITE 160 TUKWILA, WA. 98168 PER IBC 2006 EDITION SECTION 2208 STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -14858 EXPIRES 12 -26 -11 ~REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 8 2010 City of Tukwila BUILDING DIVISION Cm OF TUVIiY1gLp JUN 181010 PERMIT CENTER Up 0 BY G. OHANIAN DATE. 6 -5-10 SUBJECT RACK DENI(N & EN(fINEERIN( CO. 412 WE ph BROADWAY, QUITE #204 ddLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 2 JOB NO. RD -14858 CO U, 0 120" I f Ii L i' 4 FRONT VIEW BEAM M= 120"x1.0 K.15 "K 8 15"x SR— = .45 <1.09 A. 5xWxL 3 — 120 _ 384x1x xE .27 < — 67" 180 • / N rr C. SIDE VIEW LOAD PER BEAM + 25% IMPACT LOAD (2Kx.88) +(1 Kx.25) = -a- = 1 K 2 BEAMS Ix =2.86 Sx =1.09 F Y= 55 KSI. SEISMIC DESIGN V= R XI xWx.75x.67 CBC 2007 —SEC. 2208, PER RMI SPECS. ASCE 7 -05 (SEC. 15.5.3) SDS =1 (USGS WEB SITE, "SITE CLASS D ") 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED W =D.L.+ 3 PALLET LOAD LOAD PER COLUMN PALLET LOAD= 3 x 22coL. 1.3 K .08 K 2 -K LONGIT. SEISMIC Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4954 Longitude = — 122.2912 Spectral Response Accelerations SMs and SMI SMs = Fa x Ss and SMI = Fv x SI Site Class D — Fa = 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 1.497 (SMs, Site Class D) 1.0 0.774 (5141, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4954 Longitude = — 122.2912 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SW Site Class D — Fa = 1.0 ,Fv = 1.5 Period So (sec) (g) 0.2 0.998 (SDs, Site Class D) 1.0 0.516 (SD1, Site Class D) W=.24- 1.3Lf 1.5 K _ 12 K vLONGIT. V = .19K TRANS. 04K 2 "K 12 K 0 7 -K BY G. OHANIAN DATE . 6-5-1Q SUBJECT RAdK DEOI(N & ENdINEERINd do. 412 WET BROADWAY, gUITE #204 LENDALE, dA. 91204 TEL:(818)240 -8810 FAX:(818)240 -3813 SHEET NO 3 JOB NO.. RD -14858 COLUMN ANALYSIS 3" M tt x- t =.07' II II COMBINED STRESS RATIO Qc.P +Qb.Cmx.M =.47<1 Pn M,,.ax BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .12 K Fy =55 KSI Ae =.59 I x =.95 Se =.6 rx =1.2 ry =1.1 ri<xl = 58x 1_7 — 82 Fe= 7T rx E� 2 = 43 KI __ 52 _47 A2 rY Fn =Fy (.658 c )= 32 KSI M„ =Se .Fy =33 Pex = n 2E.IX = 28 (Klx) 2 ax =1— Pex 90 ex (1) -1/2 "0 HILTI KWIK BOLT —TZ ANCHORS (ESR -1917) PER BASE PL., 3 1/4" EMB. SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x 1x65 =2.3 K BEARING CAPACITY OF COL. HOLE 7/16 "0 RIVET A = .1 Fy = 79 KSI Pa = .1 x79x.4 = 3 K Oc =1.8 (fib =1.67 Cmx =.85 Ma = (2.3Kx4 ") +(1.2Kx2 ") =11.6 K 3 PIN CONN. CONN. M END= .O1XWI2 = 1.2 "K M = 4.5 "K M =5.7 "K SEISMIC TOTAL Pn= Fn.Ae =19K 4.5 "K 1.5 K Ac= F7e =1.13 Ac <1.5 3"x4.5"x1 /8" BASE PLATE BY G. OHANIAN DATE. 6 -5 -10 SUBJECT RAdK DEOI(N Sc ENGIINEERINGI do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 4 JOB NO, RD -14858 OVERTURNING MoT= •19Kx2 x130 "x.66 =32 "K COL. MR = 1.5 Kx44 "x.6 = 39-K NO UPLIFT LOAD TO DIAGONAL P = .19 Kx cox 44 = .50 K Fy =55 KSI A =.31 rx =.48 Q =.74 L= 58" Fa = 10.6 KSI Pa = 3.3 K CHECK WELDS P°= (1 -) L.t.F„ = 5.36 K CQ= 2.55 ELL= 2.1Kx2 =4.2K SIDES CHECK SLAB 1500 1000 1. 5°' 1 =15" .19K 1.5x144=216 M= (12 )2x1000x 2 x12 =510 "# 5= 12x52 = 50 6 510 = 10 <1.6 2500 =80 50 1.5K 1.5K •f7 19K 44" TOP LEVEL LOADING W= -21)&1.° x-1.2 K LOAD PER COL. V= .15K MOT = .15Kx2 x130 " = 39 "K COL. MR = 1.2Kx44 "x.6 = 32 "K UPLIFT = 39-32 .16 K BOTH SIDES TYP. t =.07" 1500 6 5" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL 12 -01 -2010 RICHARD BALDWIN 727 S KENYON ST SEATTLE WA 98108 Jim Haggerton, Mayor epartment of Community Developmer t Jack Pace, Director RE: Permit No. D10 -160 3311 S 120 PL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 01/23/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 01/23/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D10 -160 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 e Fax: 206 - 431 -3665 • PUNIC RD C4PY° PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -160 DATE: 06/18/10 PROJECT NAME: REISCH I LLI NG PRESS INC SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS. Bui in P'vision Public Works A III j PreventjA- Fire n Structural -10 Planning Division UPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 06/22/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required Ti No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/20/10 Approved n Approved with Conditions ❑ Not Approved (attach comments) X Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LQI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2012 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING a ENGY Construction Contractor General Unused 4/20/2009 4/20/2011 Active EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Relicensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner /Member 12/22/2005 Amount PATTON, DAVID Partner /Member 01/06/2006 BAW54192293 PATTON, RODGER Partner /Member 01 /06/2006 PATTON, MATTHEW Partner /Member 01/06/2006 Continental Western Ins Co Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS Et SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2010 $1,000,000.0006 /01/2010 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003 /23/2009 1 ALASKA NATIONAL INSURANCE CO 05GLS31381 07/31/2005 07/31/2006 $1,000,000.0001 /03/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/27/2010 — _J 59'-8" 94,-4" IX EX RAC< -OR PEP IV! STING RACKS RACK R-M-I1 :0! C2) CN ; , M It PLAN 'VIEW SCALE: 1/8" = 1'-0" 26'-9" 24'-6" .44.4i14,0s041%.* ><S „.„0A0AA r,-40 0A0 Nc shall be Mad() ti) ' the scope 01 without pviov approvzd f Tukwila Building Division. ReViSiOnS R.-N11.1ir(,,, • • .1 aciditiona 0 04 ei0,4444 e 000 000 W000000000000AWAWA §.41,.44FAVII!!!.N.Q8141.,;, - :AAA-A 00••-•,.....AiA.- „ , pa SITE _ MAP WA *AZ A A.AAAW WA.AAAMAA. , • ?9,NSONNI6 "R4R00m teg2c+404WAA mo0y*W 000:00400 NO FILE COPY It No. )proved Field o)y • By I REVIEWED FOR ODE COMPLIAN( APPROVE,” Jul (Pk City of Tukwila BUILDING DIVISION City Of Tukwila Lrr RL i40 _ CITY OF' 2010 PERMIT CENTER SHEET DESCRIPTION o = PROJECT TITLE PALLET i` A CK PERMIT REISCHLING PRESS ---===--is Ln _, o z - 1 NORT ANCHORAGE m PORTLAND C - ak 20TH PLACE SUITE 160 -_- IA I~I D I I[ I :G 5 5 E" t` S I t l SPOKANE z ..::d'�.nr3r.. -h e._.,.....r.,: EUGENE i SCALE AS REVISIONS 1100 SW 7TH STREET YAKIMA P1 SATE 6/8/10 98055 RENTON A 9�O5 (425) 255 -0500 DRAWN BY KEITH WERNER DRAWING 1 3/4" TYP 1 � e q d q A 0 q q q q ° ►0 ° °o ° ° � q o d d 0 dAr q ° °Q� q C 4G Av Q Q 1 r f r f f � G O A Q I 111 41 A ; ;