HomeMy WebLinkAboutPermit D10-164 - MCCLOUD RESIDENCE - REMODELMcCLOUD RESIDENCE 4014 S 115 ST D10 -164 City oftTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: htux//www.ci.tukwila.wa.us Parcel No.: 3351400625 Address: 4014 S 115 ST TUKW Suite No: DEVELOPMENT PERMIT Permit Number: D10 -164 Issue Date: 08/19/2010 Permit Expires On: 02/15/2011 Tenant: Name: MCCLOUD REMODEL Address: 4014 S 115 ST , TUKWILA WA Owner: Name: BANK OF AMERICA NATIONAL AS Address: 2780 LAKE VISTA DR , LEWISVILLE TX 75067 Phone: Contact Person: Name: JOHN MCCLOUD Address: 1818 WESTLAKE AV N #216 , SEATTLE WA 98109 Phone: 206 396 -9862 Contractor: Name: OWNER AFFIDAVIT - JOHN MCCLOUD Address: Phone: Contractor License No: Expiration Date: DESCRIPTION OF WORK: REMODEL OF EXISTING HOME Value of Construction: $20,000.00 Fees Collected: $779.67 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0022 * *continued on next page ** doc: IBC -7/07 D10 -164 Printed: 08 -19 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: //www.ci.tukwila.wa.us Permit Number: D10 -164 Issue Date: 08/19/2010 Permit Expires On: 02/15/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: L'qlo I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf• . ce of .. .!I am authorized- to-ign and obtain this development permit.. Date: r ' y � U This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -7/07 D10 -164 Printed: 08 -19 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Parcel No.: 3351400625 Address: Suite No: Tenant: 4014 S 115 ST TUKW MCCLOUD REMODEL PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10 -164 ISSUED 06/25/2010 08/19/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All wood to remain in placed concrete shall be treated wood. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 14: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 15: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: Cond -10/06 D10 -164 Printed: 08 -19 -2010 • City of Tukwila �y Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us • 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 D10 -164 Printed: 08 -19 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: A Date: .Y.-/ (� ( ( ordinances governing or local laws regulating doc: Cond -10/06 D10 -164 Printed: 08 -19 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Project NO.: :(For ofce:,use•only)Y':'... Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** c ! /(S— f-47-04,,, King Co Assessor's Tax No.: �'l M �% ` t/(�t ZC Site Address: Z �l �. �A �Jl. 9�' /Cos Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes El ..No Property Owners NameM`tt 0 Lice Mailing Address: C-J L.9-k E E. N. ?ice f64-71-1_6 6el1, j &lc, F City State Zip CONTACT PERSON •- who do we contact when. your permit is.ready to be issued r Name: Mailing Address: E -Mail Address: c J.) Day Telephone: (.6',€) >s4. - t'eS1 6 �- City State Zip c� fl�i Lit 6 pet Y - TL6-9CD rv( Fax Number: 6> R&5 - /6'03 GENERAL CONTRACTOR INFORMATIONS (Contractor Information for Me chanieal:(pg. 4)'114 PI'umbing and Gas Piping (pgs5)) Company Name: 01i Mailing Address: State Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: Zip :.ARCHI:TECT.OF.RECORD =All plans:;must tie wet stamped by,• Architect of Record • Company Name: iv ("1— - - Mailing Address: Contact Person: E -Mail Address: LNGINEER OF :RECORD - All plaits mast ofR`ecolyd City Day Telephone: Fax.Number: State Zip Company Name: 7∎ Mailing Address: Contact Person: E -Mail Address: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING" PERMIT INFO.R Valuation of Project (contractor's bid price): $ " SOO Scope of Work (please provide detailed information): &E 4-u9 OC L OF L k (S7-i") 6 Goo nt�� Existing Building Valuation: $ Will there be new rack storage? ❑ Yes ®;. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below; PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None IZL Other (specify)$1/"Xke Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ia---. No If 'Yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H;\Apphcations\Forms- Applications On Line \2009 Appl icationsll- 2009 - Permit Application. doc Revised. 1 -2009 bh Page 2 of 6 Existing 1n terror Remodel . A.ddition;.to Exis ru`` • Structure . New AType of" -' Construction per ;i- IBC .:' Type of•',-:' Oc cupancyp e r '. ...• .IBC < * . . 1St Floor 7CO U Q r3 2nd 'Floor • 3`- d•Floor Floors.. thru. Basement 0 6 v e 7 ,Accesso'ry'Struci:ure *' • !:Alttached Garage: . ..I , ::D'etached Garage; - ..•.�,.'�, :.. -.;:° . .. ,' Attached; Carport:. . •' Detached•. Carport Covered!D"eck. -• • Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None IZL Other (specify)$1/"Xke Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ia---. No If 'Yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H;\Apphcations\Forms- Applications On Line \2009 Appl icationsll- 2009 - Permit Application. doc Revised. 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES— Applcable to`aU "peririits in,thsapplcatouw ti Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER r :a•... _ -,u„� D AGENTS Signature: ` / Print Name: vbl .n C __ o Mailing Address: ( / b Day Telephone: Date: S � (Z 'C) _VG- - Oc'6Z City State Zip Date Application Acted. Date Application Expires: �/ Staff Initials: H:WpplicationsTomts- Applications On Line \2009 Applicat • s \1 -2009 - Permit Application.doc Revised: 1 -2009 bh 3 Page 6 of 6 PLUMBING AND GAS :PIPINGRIVIITII PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: //9' Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Ft7-' /� Indicate type of plumbing fixtures and /or gas pip' - : outlets being installed and the quantity below: Fixture Type: Qty Fixture T : e: Qty Fixture Type: Qty Fixture Type: Qty ; Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Dri• ing fountain or ter cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap avatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent / Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease intercep .r for commercial - chen (>750 gallon cap. • ty) !! Repair or alteration of water piping and /or water eatment equipment -tom Repair or alteration of drainage or vent piping ( 1 yy Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each a• • itional medical gas i ' ets /outlets greater tha 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets /� `� H: Applications\Forms- Applications On- line\2009 Applications11-2009 Permit Application.doc Revised: 1.2009 1 t 5,19 bh l Page 5 of 6 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3351400625 Address: 4014 S 115 ST TUKW Suite No: Applicant: MCCLOUD REMODEL RECEIPT Permit Number: D10 -164 Status: APPROVED Applied Date: 06/25/2010 Issue Date: Receipt No.: R10 -01637 Initials: User ID: Payee: JEM 1165 Payment Amount: $474.30 Payment Date: 08/19/2010 04:01 PM Balance: $0.00 PACIFIC PROPERTY & INVESTMENTS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1105 474.30 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $474.30 469.80 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -19 -2010 of Tukwila. 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: Initials: JEM Payment Date: 06/25/2010 User ID: 1165 Total Payment: 458.22 Payee: PACIFIC PROPERTY & INVESTMENTS, INC. SET ID: 0625 SET NAME: MCCLOUD SET TRANSACTIONS: TOTAL: 305.37 TRANSACTION LIST: Type Method Description Amount Payment Check 1070 458.22 TOTAL: 458.22 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - RES 000.322.101.00.0 PLAN CHECK - RES 000.345.830 152.85 305.37 TOTAL: 458.22 PAYMENT RECEIVED INSPECTION RECORD Retain a copy with permit INSPECTION NO PERMIT NO. _i \\\\V CITY OF TUKWILA BUILDING DIVISION "• 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670• Permit Inspection Request Line (206) 431 -2451. • Proj t L(4 ype lnspectigp:1 P Address: - bate C led: - o44 J Special Instructions: • • • Date Wanted:. l 1 p.m. Requesters Approved per applicable "codes. Corrections• required prior to approval. COMMENTS: pspector: IDate:��� . r7 REINSPECTION FEE REQUI ° ED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100'. Call to schedule reinspection. ..r`.;.14.• p,..e�. • • .:ey :.5. •.:S!"•1•tr.- 11x-Lati.:1. • y- •■••••R{•x r 12 . INSPECTION NO. INSPECTION RECORD Retain a copy with permit C41-- Po PERMIT NO. CITY OF TUKWILA BUILDING DIVISION E..E4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: . (!i IAN �. C(� 8,10:A, nemD / -7(e Type o I p ction: A es 14.9. 1 S4 Date Called:a /� Special Instructions: Date Wanted: a.m. Requester: . )01-1,-) Me e iolAd Phone No: ]',, ci 1p ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: (!i IAN �. C(� 8,10:A, nemD / -7(e {._)f-A c e ,, p 6.-(-7-: .) 4 .g.- SA-1 d --Ay (, ) o l i ( , f& - , ,1 (e 1--Aft- 1 -_ -/ Lo — /,_D • Inspec r: Date: IT $60.00 REINSPECTION FEE REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt NO.: Date: • INSPECTION RECORD Retain,a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd'.; • #1'00, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: VYIC. ...dttb► i'�.e tin o f L_ Type of Inspection: t,� Air 1149.E L A"l~I d eJ , ) d Address: "IOtL S. 1 -1 -5 ' Date Called: ¢ ,., Special Instructions: • • Date Wfanted:"rrlj Requester: P one No: Approved per applicable codes. ; 1J Corrections required prior to.approval: COMMENTS:.It 't- , ) d 4 u - . L S i ¢ ,., *-7, -r P it - bt it �—`l°.'�`° ?• �] 6" . 9 ... , - - - -. - --. • • . V-- .~ ) • 6 j r J V� ,i� (. ,, A , , k r . �,, -- lel �4 '' A L ' .. lei z"..... fr ! 1]1 0.>1 i.� ''� iREINSP1Et TIQN FEE QUIR =D: Prior to next inspection, fee must be ,"-.. d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ;,Y . r* 1014-" we wr . sIve ...w - . ...., •* .,+sue CI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Duo -//9 PERMIT NO. OF TUKWILA BUILDING DIVISION (206)431 -3670 Pro ,ectt/ 9 /Type ( of Ins ction: • Address: Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: zee— 39t — 9862 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 REINSPECTION F REQUIRED rior to inspection, fee must be at 6300 Southcenter : lvd., Suite 1 r 0. Call to schedule reinspection. Rec Ppt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 9818• •• (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro. i c : y (Jsi 4e ie, .9kjype orr�do ,A .��.- Qr Address . s:: Y ate Cd: r� b a e . f _ Special Instructions: - r- '", . r . . L. Date Wanted: C'7 -(Co -. /c .m. m. Requester: Phone No: Approved per applicable codes: - a Corrections required prior to approval. • COMMENTS: /1,444.-" (. est rte; r,t4 b t( f • - Asa 4 REINSPE•CTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. E•. • • • • • y. • 1.. .1,1112PCIlio -.111,a1.17,13. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Er CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: . Address: 4/141 ' 1/4.5 Date Called: _,S" _ Special Instructions: • .. • Date Wanted: 9 --- / _/e.) • p.m. Requester: ro r . A.s- re,, _;-_4 A 4 Phone No: ez106 rile -''8C'? Approved per applicable codes. orrections required prior to approval. COMMENTS: _Aet p k ) . /.6) ,r-M.e.At p k't`fr. 71,-,44.1- Ole („A4vt,AT DO A -r/.A, i , ^cp l d t ( - d { Le t.. rttri iQ .A 'ef Ad 1 `r" k ide e. AI i J P. A� - _p_�=�+� 1 1 1 1_ ( Le.. t (u�I, i - c o . Y L j - 3k_ ,)i*.d 611/4 _ - ro r . A.s- re,, _;-_4 A 4 reirm=r- ' Vim/ £L- LTD d,e ` t EX l s1 v 1 P REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. t• • • , • INSPECTION NO. INSPECTION RECORD Retain a copy with permit ("frt.,( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 ati( t:� (W v C0 �`� `u �l qTYPe yy,�(__ //1t11 C Type of fl% it 4 nt 6 Ad ress: 014{ s • (IS sT"� Date :Called: /f rtc- g-EAik `4 , uu iu iy' 4 & Special Instructions: Date Wanted: a.m. 243 Requester: Phon cNg: 35. tv ......7s ,c, Z ElApproved per applicable codes. orrections required prior to approval. Z COMMENTS: /f rtc- g-EAik `4 , uu iu iy' 4 & ✓-'' T) I,-^ C_ c.4 !i U ( C_O of (o o U ,A (.‘ -' .ek " l� ousel r e U ,,'. �CAl.j Tel 4(J . Kos Or, r et,OJQ 1 / Inspect�6r: Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be ,,paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: PAGE 02/02 2068051803 06/25/2010 SL a' 31. Pro PEETV . A ao7E,SS 4b14 5 115 5� 5tAT 1. -, gal 1.1)?) iPArzcE,L. t 35519' 0 -etpzS 0 A- YY1 AS C3 to l -- EYzrly nb)2-TO (l Si sei n IT'R-T10Y1. 800= 4i33- 1(018 4 4 CODE SEWED F0� APPROVED IWOVED AUG 13 2010 BUODof Tla NG DIukwiVI41f1U RECEW GIN OF TU LA JUN 2 3.2010 PERMIT CENTER Rio -icy STATE OF WASHINGTON • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplanicici.tukwila.wa.us AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY ss COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City, its employees, agents, en ineers, contractors or other representatives the right to enter upon Owner's real property, located at t-{ 0 1l y s. 1 1- 6+, -ri k„ t l_4 t.J14 . rj $1( for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any Toss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. The City shall, at its discretion , cancel the application without refund of fees, if the applicant does not respond to specific requests for items on the "Complete Application Checklist" within ninety (90) days. EXECUTED at 7 l i ) (city), L()/1 (state), on Au9aSj' a ,20 )cD (Print Name) (8 ( 3 C..JeSt /0. F roc - 2-16 SPa p[,1a. (drib) (Addy ss) (2 ) ? - (Phone (Signature) On this day personally appeared before me J6�►n ► r c_CLu_G( to me known to be the individual who executed the foregoing instrument and acknowledged that he /she signed the same as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON T S Cq DAY OF AtILI S ggNIIN111 Altgj' it O ARY PUB in, /and for the State of Washington ON III residing at Jurltvtfr A,Q� a�r My Commission expires on (6 /grf /1"( 1 14,1, O�11WAS"�`p ,„ C:\ Users \John\AppData \Roaming \Barca\Attach \Boundary Line Adjustment -Lot Consolidation- Ju12010.doc 20!() RECEIVED AUG 02 2010 PERMIT CENTER • • Return to: City Clerk City of Tukwila 6200 Southcenter Boulevard Tukwila, WA 98188 Above this line reserved for Recorder's use HOLD HARMLESS - SENSITIVE AREA Grantor /Borrower: JAG. <A,L to, , P .Ft5. Grantee /Beneficiary: CITY OF TUKWILA, a municipal corporation of King County, Washington Document Reference Number(s): Section/Township /Range: Assessor's Tax Parcel Number(s): 335 /4/0062-5- 335 /'JOO2■00 Property Legal Description (abbreviated): L DTS 3/ '/ 3 9 Jo (IDS .diOck2.0 C D. /-('c�14 s 6L L'/9-2o +.J &,4/e o &iuS Di) r 7-10,\J �-O c t r y OF SE it- IrL6 D i v $ iOW fv0 . 3 , 4 LC 0 2_0 /v 7z7 rife roL/F- Oi", /2(5c.02oc0 (V ✓n u.nc ;z 0 pt_. i i'96tCs) 8,6, %N K ( & COv ir)/i1-54 G7-0 i , COVENANT AND HOLD HARMLESS AGREEMENT - Sensitive Area Page ( of • • SENSITIVE AREA COVENANT AND HOLD HARMLESS AGREEMENT This covenant and hold harmless agreement is entered into between b,;(c.C(a (0�,. PP[ , (Individual(s) (Corporation) , ( "Grantor), and the City of Tukwila, a Washington municipal corporation ( "Grantee "). RECITALS WHEREAS, Grantor owns and has applied for necessary permits to develop certain real property (the "Property ") legally described in Exhibit A, which is attached and incorporated by reference. WHEREAS, a portion of the Property contains sensitive areas of potential geologic instability (potential slide areas) as depicted in Exhibit B, which is attached and incorporated by reference. WHEREAS, as a condition of the issuance of subdivision plat approval, land use permits, and /or construction permits for the Property, the Grantee required the Grantor to execute and record this "Sensitive Area Covenant and Hold Harmless Agreement" to hold the City of Tukwila harmless from all loss incurred as a result of any landslide or seismic activity, or soil disturbance. WHEREAS, Grantor assumed this obligation in order to obtain said subdivision plat approval, land use permits, and /or construction permits for the Property. WHEREAS, the parties agree that this agreement constitutes an arms length, bargained -for agreement, which includes a waiver of liability that runs with the land for risks created by the proposed use of property because of the shape, composition, location or other characteristic unique to the Property sought to be developed. NOW, THEREFORE, the parties agree as follows: AGREEMENT 1. In consideration of Grantee issuing subdivision plat approval and /or other development permits, which constitutes good and valuable consideration, the receipt of which and the sufficiency of which the Grantor hereby acknowledges, the Grantor shall defend, indemnify, and hold the Grantee, its officers, officials, employees, agents, and assigns harmless from any and all claims, injuries, damages, losses, or suits, whether brought by grantor or third parties, including all legal costs and reasonable attorney fees, arising out of or in connection with any injuries or damages to persons or property caused in whole or in part by any landslide or seismic activity or soil disturbance on the Property, legally described in Exhibit A, which is attached and incorporated by reference. COVENANT AND HOLD HARMLESS AGREEMENT — Sensitive Area Page Z of • • 2. Grantor on its own behalf and on behalf of its heirs, successors and assigns hereby waives any right to assert any claim against the Grantee, its officers, officials, employees, agents, and assigns for any Toss, or damage to people or property either on or off the site resulting from any landslide or seismic activity or soil disturbance on said Property by reason of or arising out of the issuance of the permit(s) by the City for development on said Property except only for such losses that may directly result from the sole negligence of the City. 3. Grantor will inform its successors and assigns of said Property that the Property is in an area of potential geologic instability (potential slide area), of the risks associated with development thereon, of any conditions or prohibitions on development imposed by the City of Tukwila, and of any features in this design which will require maintenance or modification to address anticipated soils changes. 4. Grantor will maintain continuous insurance coverage as required by the permit authorizing the development. 5. Grantee's inspection or acceptance of any of the Grantor's construction or other work either during construction or when completed shall not be grounds to avoid any of these covenants of indemnification. 6. This covenant and hold harmless agreement shall be a covenant running with the land and the rights and obligations contained herein shall run with and burden the Property, including each parcel comprising the Property and shall inure to the benefit of and be binding upon the Grantor and Grantee, their successors and assigns. COVENANT AND HOLD HARMLESS AGREEMENT — Sensitive Area Page 3 of ___ • • DATED this day of , 20 GRANTEE: CITY OF TUKWILA Mayor ATTEST: City Clerk STATE OF WASHINGTON ) ss. County of King On this day of , 20 , before me, the undersigned, a Notary Public in and for the State of Washington, duly commissioned and sworn, personally appeared and , known to me to be the Mayor and City Clerk, respectively, of CITY OF TUKWILA, the municipal corporation that executed the foregoing instrument, and acknowledged it to be the free and voluntary act of said municipal corporation, for the uses and purposes mentioned in this instrument, and on oath stated that he /she was authorized to execute said instrument. WITNESS my hand and official seal hereto affixed the day and year above written. print name NOTARY PUBLIC in and for the State of Washington, residing at COVENANT AND HOLD HARMLESS AGREEMENT — Sensitive Area Page L of _ O TS L-� t L_._ S -1)46 C_CO20t Rt C_0266b t (, IfJ i< ( • EXHIBIT A LEGAL DESCRIPTION OF PROPERTY / 3 ci %-'D L10. 3LO G('- QC—; C D u( R DE S A-o Q r ri DA) re �-P SE 4---r(--Le , lLI i sio" NJn . 3, m - me O F, IN ©t_v Fa_ of f� -S; p4-6C (5) nI L- CO U NITV / c,,J 19-St i nl 6%014 COVENANT AND HOLD HARMLESS AGREEMENT — Sensitive Area Page S of • • EXHIBIT B DEPICTION OF SENSITIVE AREAS COVENANT AND HOLD HARMLESS AGREEMENT — Sensitive Area Page 6 of • • DATED this day of / vY 20 /0 GRANTOR(s GRANTOR(s): GRANTOR(s): individual(s) STATE OF WASHINGTON ss. COUNTY OF KING On this ( day of Attep,01- , 20 ) U , before me a Notary Public in and for the State of Washington, personally appeared Tain me_cloLA , and to me known to be the individual(s) that executed the foregoing instrument, and acknowledged it to be the free and voluntary act of said individual(s), for the uses and purposes mentioned in this instrument, and on oath stated that he /she /they was /were authorized to execute said instrument. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. a (L)jL' ' ``%%% % % % % % %%%%%%%%%% (/ ‘5.- ca A. 14,„114, Name: - Oct y -,e ,- Ctlerk ������ "'''' ���' NOTARY PUBLIC, in and for the State of �' +°TAI- So Washington, residing at : , s _ °_ rn: My commission expires: C /.2-9// Y Page7of • • DATED this day of , 20 GRANTOR(s): GRANTOR(s): GRANTOR(s): individual(s) STATE OF WASHINGTON ss. COUNTY OF KING On this day of , 20 , before me a Notary Public in and for the State of Washington, personally appeared , and , to me known to be the individual(s) that executed the foregoing instrument, and acknowledged it to be the free and voluntary act of said individual(s), for the uses and purposes mentioned in this instrument, and on oath stated that he /she /they was /were authorized to execute said instrument. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. Name: NOTARY PUBLIC, in and for the State of Washington, residing at My commission expires: Page of ■ • Citj/ f Tu 1 Jim Haggerton, Mayor Department of Community Development John McCloud 1810 Westlake Ave N, #216 Seattle, WA 98109 RE: Incomplete Letter #1 Development Permit Application D10 -164 McCloud Residence — 4014 S 115 St Dear Mr. McCloud, Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 25, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached comments. Planning Department: Stacy MacGregor at 206 433 -7166 if you have any questions regarding the attached comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have any questions regarding the attached comments. Please address the attached comment in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. rshall ician Enclosures File: D10 -164 W:\Permit Center\Incomplete Letters \2010 \D.l0 -164 Incomplete Ltr # 1.DOC 6300 Southcenter Boulevard, Suite #100 e Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 • al Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: June 29, 2010 Project Name: McCloud Residence Permit #: D10 -164 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) L The plans provided are a little confusing to determine exactly which is new /proposed or existing. Please clearly cloud or highlight scope of work for all portions that are new for this permit. Provide specific details for the new work if it is not shown on the plans. Clearly identify any setbacks that may be affected with dimensions. Provide complete details with all dimensions including specifications for hardware and materials for all new proposed work. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. DATE: APPLICANT: RE: ADDRESS: PLANNING DIVISION COMMENTS June 30, 2010 McCloud Residence D10 -164 4014 S 115th Street Please review the following comments listed below. If you have any questions on the requested revision, Stacy MacGregor is the planner assigned to the file and can be reached at 206 -433- 7166. Please cloud the plans to show what is existing and what is proposed. It appears that you are remodeling the interior of the home and only increasing the footprint with a front porch? Setbacks: The site plan needs to show setbacks from property lines. The porch needs to be at least 15' from the front property line. The rear property line appears to run through center of home. Lot Consolidation Needed: On our CityGIS system, the rear property line appears to bisect the home. The property to the rear is owned by the same entity. The front lot is substandard in size but in combination with the rear lot the lot area will meet code. Code does not allow an increase in nonconformity. These two lots need to be combined in order to increase the size of the home in any way. Class 3 slopes: The site is mostly made of Class 3 slopes. Execute the attached hold harmless agreement for work on steep slopes (per Joanna Spencer of Public Works). Roof pitch: Show the roof pitch for all new roof sections. Lot coverage: The plans include a table for lot coverage and impervious area. Revise the table to include what the impervious area includes. Again, I am confused if the impervious area indicates the lot coverage after the remodel. Modify the table to label existing and new lot coverage. PUBLIC WORKS DEPARTMENT COMMENTS DATE: June 29, 2010 PROJECT: McCloud Residence 4014 S 115th Street 1 PERMIT NO: PG 10 -007 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Since the property is on a septic system approval for your porch addition and house removal from King County Environmental Health Department is required. Please contact King County Wastewater Program, Black River Environmental Health office at 900 Oakesdale Avenue SW, Suite 100, Renton, WA 98057, phone 206 296 -4932 to start the process. Submit copy of the above king County approval. H: Joanna/D10 -164 inc • 1 d ' AEI PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -164 DATE: 08 -02 -10 PROJECT NAME: McCLOUD RESIDENCE SITE ADDRESS: 4014 S 115 ST Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: �'-�u li din • J ivislon SiPublic Work � A vA AVA- Fire Prevention Structural tite cA'10'0 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-03-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route N. Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-31 -10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • r) EMT COORD COP. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -164 DATE: 06/25/10 PROJECT NAME: MCCLOUD RESIDENCE SITE ADDRESS: 4014 S 115 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPA TMENTS: Bui di g � Ivisl` at el, n, , ! t7 Public or Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete U Comments: DUE DATE: 06/29/10 Incomplete 14 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: InI OIfl LETTER OF COMPLETENESS MAILED: ��,,�� Departments determined incomplete: Bldg Xi Fire El Ping% PW% Staff Initials:' TUES /THURS ROUTING: Building Please Route n Structural Review Required _ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/27/10 Approved U Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / I l a Plan ChecWPermit Number: D10-164 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # Y op TUKWILA ❑ Revision # after Permit is Issued I at6 ©2 2010 ❑ Revision requested by a City Building Inspector oy1'lans Examiner PERMIT COMP Project Name: McCloud Residence Project Address: '4014 S 115 St n > Contact Person: Jatt.�• ��� t / t9 , rX Phone Number: (.4)96- 6J 3 Summary of Revision: /EGA. - o .r t -P r c A-1 r /Y. C... /c/e. e �olG�s, from /a l`Gcn -s, Rex, ode_ / ft, .^ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ) & Z1 Entered in Permits Plus on 046?- //6 \ applications \forms- applications on line\revision submittal Created: 8 -1.3 -2004 Revised: • CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplan0ci.tukwila.wa.us • Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: ' V STATE OF WASHINGTON) ss. COUNTY OF KING Cl e\.1 , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Signed and sworn to before me this day of , 20 (6 . Oak �p /W .c OT ' Y PUBLIC in and for the State of Washington Residing at )"41.)-41.1 , County Name as commissioned: e huil '4 e My commission expires: O.S 99—/ 7 18.27.090 Exemptions, The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician;'a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. A Ay 0 MED 1 FILE COPY PermkNo., Vt91(A Plan review approval is subject to errors and omissions. Approval of construction documents does rot authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy ns is a Wedged. # # 1/11 lgr" AIM MUM AM M /MN _ onr 9 - - -- 1' 7 41".. d i ,o4ir,r441 fr 41/( ,4 .AS inA4 4;7 --- — - :44 ■ 4.cri r 4,1://4rtir,"411!41;:iraii AP 4 SEPARATE PERMIT REQUIRED FOR: I:5Z Mechanical 15/ EleCtriCal Plumbing 1§ Gas Piping City of Tukwila BUILDING DIVISION 4 : - -,40-114.14 __. -14.-te-Ottr-Eso•Arce4 UcX) r‘ eio .191A0 -0D7-1/Lotia- - - 174-41-4-37791-40 --14,t914*0- -40k4 I111 r - rt-Ati?ttle:\t7.0.10,citito MIwaagigligNiotalseitairerfrp 1 clARSILA JUN 2 5 2010 PERMIT CENTER REVISIONS No changes shall be made to the scope of work without prior approve! of Tukwila Building Division • NOTE: Revisions will require a new plan submittr! and may include additional plan reviow fces _ INCOMPLETE LTR# EXISTING 4x8 DF #2 BM NEW 3 1/8 "x10 1/2" GLB UNDER. 48 DF#2 BM STRAPPED TOGETHER w /PS218 0 4'3 " AC (SIMPSON R313. 1 Smoke alarms. Smoke alarms shall be installed in the following locations; 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms; 3.On each additional story of the dwelling, including basements but not including crawl spaces ', and uninhabitable attics. When one or more smolt' alarm is required to be installed within an individual dwelling unit the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarm in the individual unit. The alarm shall be clearly audible inn all bedrooms over background noise levels with all intervening doors closed. 8313.2 Power source. In new construction the required smoke alarms shall receive their prmary power from the building wiring...wiring shall be permanent without disconnecting switch...when primary power is interrupted, shall receive power from a battery, (2)3Q FR.DR. (, .. OOF CO 24; EXIST. BD. OVER — FRAMING EXIST. KITCHEN EXIST. BATH' 2a EXIST. LIVING /DINING ® 3M UP. ' EXISTING 4x6 I)F #2 POSTS ® EA riC: o:- EXISTING 4x8 DF #2 BMS. ADD 3 1 /8 "x10 1/2" TO EXISTING BMS. HAND ON POST w/ TYP. EXISTING 4x6 svP 1 ?n1ifi * ALL EXTERIOR HEADERS TO BE 6x12 DF #2 UNO. * ALL INTERIOR POINT LOADS TO BE 4x6 DF #2 * ALL EXTERIOR POINT LOADS TO BE 6x6 DF #2 POINT LOADS TO BEAR ON FD /PADS OR BMS. BM CALC'S 480Ibs /ft. 12' SPAN 12x12+ 360 =.40 480x.12 +2x 1.5 -1-165 =26.18 480x122 8x12 =2200 =47.12 480x5x 124 -:-384_ 1600000 =Ix 1728 =.33 (.081) (412.65) ADD 3 1/8"x10 TOTAL 58.18 88.06 (T) 412.65 1/2" GLB NEED 26.18 47.12 350.0 (COMBINED CALC'S City otTukWII& BUILDING DIVISION „ RECEIVED 1 �4 AUG 02 2010 _ PERMIT CENTER POST, �IEADER, & BEAMS TO BE DF #2 UNO. BUILT )P BMS TO 3E GANG NAILED w/2 ROWS 20d ® 16 "OC. USE 0JL.Y APPROVED BRACKETS, STRAPS, HANGERS, & HOLDOWNS. S tce-s . id.{ z. 29 -0'oK. • SEP 08 ?oi is ; i : :nIltaf