Loading...
HomeMy WebLinkAboutPermit D10-175 - WESTFIELD SOUTHCENTER MALL - NORTH STAIR MODIFICATIONSSOUTHCENTER MALL STAIR MODIFICATIONS 2800 SOUTHCENTER MALL D10 -175 City A-Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Project Name: SOUTHCENTER MALL NORTH STAIR MODIFICATIONS Permit Number: D10 -175 Issue Date: 07/28/2010 Permit Expires On: 01/24/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Phone: 206 - 624 -2777 Address: S M STEMPER ARCHITECTS , 4000 DELRIDGE WY SW - SUITE 200 98106 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Contractor License No: BNBUII *990K3 Phone: 206 382 -3443 Expiration Date: 09/12/2011 DESCRIPTION OF WORK: INSTALL EXIT DOOR AND DOOR ALCOVE FROM THE 1ST LEVEL VACANT NEAR SEAFOOD CITY Value of Construction: $5,000.00 Fees Collected: $306.95 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II-B Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -10/06 D10 -175 Printed: 07 -28 -2010 City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10 -175 Issue Date: 07/28/2010 Permit Expires On: 01/24/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie N Date: 01124$11 2 ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf oorrmance of work. I am authorized to sign and obtain this development permit. Signature: ( V Date: (ZI Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -175 Printed: 07 -28 -2010 • �wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: hup://wwwci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 9202470010 Permit Number: D10 -175 Address: 2800 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 07/14/2010 Tenant: SOUTHCENTER MALL NORTH STAIR MODIFICATIONS Issue Date: 07/28/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 10: Maintain fire extinguisher coverage throughout. 11: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 13: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) doc: Cond -10/06 D10 -175 Printed: 07 -28 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 15: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 18: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 19: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 21: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -175 Printed: 07 -28 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: C 1 ' c&1 e S4-KII7 1 Print Name: Date: ordinances governing or local laws regulating doc: Cond -10/06 D10 -175 Printed: 07 -28 -2010 1- Site Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h / /p: / /wu'u'.0 %. /1(kll'llU wa.us Tenant Name: Building. Permit i .c Mechanical. Permit. No. Plumbing /Gas Permit No. Public Works Permit No. Project No. For office use_onh) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 9 2-0 2-4-/ - Co ( Suite Number: 14/134 Floor: ?L New Tenant: ❑ Yes No 2800 LCit -- Property Owners Name: S Mailing Address: 2.-S 00 SOt.ril}C,ely- ia- g818g City State Zip CONTACT PERSON who do we contact when your permit is ready to be issued Name: 1et1c -f1,.e" .JOI(SO Mailing Address: OOO bieLe-t (X 141»( Skj``1-2op E -Mail Address: t4A'Y t4( 0-5 (Yl STEM tom` - . L-e M Day Telephone: 20 (c • 624. 27"7 7 S 18106 City State Zip Fax Number: 20 ZC.( ? 3 GENERAL CONTRACTOR INFORMATION .- (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: M t ►y, .`Jk i M i Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: State Zip Expiration Date: ARCHITECT OF RECORD, = All plans must be wet stamped by Architect of Record Company Name: 5. M . SIFlV .,, /1/412.4.-{4-1-1 E `'s I P. 1..... • l.. ( . Mailing Address: ttE OO �Et (j�L�r' 1�• r Su.( G-c Se& flL kV,— IS (o C. City _ State Zip Contact Person: 14I Y IL lt= 3 €AAMSat.1 Day Telephoner 6 ' (c2-11 • 27 7 7 Fax Number: Za t ' % 2-1 - 24f 7 g E -Mail Address: 1 t . I P E Y f - 1 C sm. we-iv! (T R . c_z> ENGINEER OF RECORD - All plans must be wet stamped by Engineer'ofLRecord„ Company Name: 1,VA Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Q:Wpplications\Fmms- Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of 6 Existing Interior Remodel Addition to • Existing Structure •New :,Type of Construction per IBC Type of Occupancy per IBC • Valuation of Project (contractor's bid price): $ 00 D Existing Building Valuation: $ Scope of Work (please provide detailed information): 1 -&S 1_L UT b �1"--- �aa �- 1 I'- 1 <S LE` Y VAC-Pvf i P n�� C Cr?' Will there be new rack storage? ❑ Yes X. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1 Floor 2nd Floor 3rd Floor (63, 72-7 2, 80 Floors : thrn ;.• 1 V We) 90 t1 it/ Pq :Basement Accessory Structure's Attached Garage' . Detached Garage.. Attached Carport -; Detached Carport • Covered:Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: /1/�- Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinlders Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Sa ' ty ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:ApplicationsWonns- Applications On IJne\3 -2006 - Permit Application.doc Revised: 9-2006 bh Page 2 of 6 ER11117 APPLICATION NOT pljcable to al'. erarr►x>fs in is PPI><a nano Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AUTHORIZED AGENT: Signature: Print Name: 14Ac-.Y Date: 7 y ' /n ,' ! Day Telephone: 2.D • (� 7. 2"%7 7 Mailing Address: L/Dv b EZ- Ielk(-, J >' 2. 0 s "7729 141 /4— 98/06 City State Zip Date Application Accepted: % Date Application Expires: Staff Initials: Gue.... Q: WpplicationsTorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9.2006 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-175 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/14/2010 Applicant: SOUTHCENTER MALL NORTH STAIR MODIFICATIONS Issue Date: Receipt No.: R10 -01430 Initials: JEM User ID: 1165 Payment Amount: $187.80 Payment Date: 07/28/2010 12:16 PM Balance: $0.00 Payee: BNBUILDERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 52261 187.80 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 183.30 640.237.114 4.50 Total: $187.80 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -28 -2010 r � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-175 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/14/2010 Applicant: SOUTHCENTER MALL NORTH STAIR MODIFICATIONS Issue Date: Receipt No.: R10 -01306 Initials: User ID: Payee: WER 1655 Payment Amount: $119.15 Payment Date: 07/14/2010 10:25 AM Balance: $187.80 S M STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15489 119.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 119.15 Total: $119.15 PAYMENT RECFIVED doc: Receiot -06 Printed: 07 -14 -2010 . • . • INSPECTION NO. INSPECTION RECORD Retain a copy with permit p o,I1 PERMIT NO. + ` •. • CITY OF TUKWILA BUILDING DIVISION . . 6300 Southcenter.Blvd:;• #100; Tukwila: WA 98188 (206) 431 =3670 .Permit Inspection Request Line (206) 431 =2451 . •. Projects�:p�y __ ►� 1 nil el 44' v m - t Type of Inspection: - ice %-" 1 m t 1. Address: 0-Q)O WN. Ir l Date Called: Special Instructions: . ......0 Date Wanted: a .. Requester: Phone NO: roved per applicable codes. ['Corrections required prior to approval. COMMENTS: 0.44-vvk.b. kft:te tOupti IV 0 R- 'PECTION FEE REQ IREDtsPrior 'o next inspection. fee must be Q pa =t 6300 Southcenter d., Suite y00. Call to sclhedule_reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY.OF TUKWILA BUILDING DIVISION 'r' 6300 Southcenter Blvd., #100, Tukwila. WA.98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Seta -t75 Project: 5th ifh c PIJ4eV W1.0211 t Type of Inspection: E trtvt6 r (-1 down a1 C Address: .„1.66 6 y01 .1-1 l Date Called: - Special Instructions: • Date Wanted: eD I2- - 2-- t0 p.m. Requester: Phone No: ..0 6 -lIg -t 856 4pproved per applicable codes. Corrections required prior to approval. COMMENTS: F iP vh e'!Y% P.5 wog ECTION FEE REQUI ED. Prio o nyext inspection. fee must be t 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection. `�'- "y�R¢F` •,yy.p.a "• ;rT T• •- ..9.{+4kP nE.y +asST'@•.'•7hlRe•4Cwitgl,-rt f+^A 7d� INSPECTION RECORD Retain a copy with permit 40/0- 17'5 INSPECT °IVO. PERMIT NO. .. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (ros) 431-3670 Permit Inspection Request Line (206) 431-2451 Projett: c.56ti.7ihC) fa*/ /409 // — , ilk Type of Inspection: r. '14 5 Are Address: Atli" OZ, 01 4 .riii • Date Called: -. Special Instructions: i q - 4/ ...,1 / .1 a 41.5- 2 xe - a / ' Date Wanted: , ...:• • 4123 /./— jet -- AO • • p:m. Requester: Phone No: a2e4-7/40-4,6114. roved • licable.coc Corrections required prior to approval. - COMMENTS: ' ANI'l -.4 • 4, rt, lnsp ctor: rate: it .....2irt) REINSPEOTION FEE RE MED.. ior o hat inspection: fee must be- paid at 63,20 southenter Blvd., Suite 10 te schedule reinspection. gampv•.irgitsc,.. ..-71%-ma.; • -- –.s•r•Y ,greceNir..z..,•ea•cfr—ge. • ... • iM.iT. !°.Y ` d1' '3R. •. fir A INSPECTION NUMBER INSPECTION RECORD Retain a copy with ,,permit ftct - ,7s— PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: $ ea 47004 C ;49 of Inspection: p,, r; .r► 4..1 Address: 1'3 7 d Suite #: 5 . C. 'i Pv,/ Contact Person: Special Instructions: F �. Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: A fl1Lt 5t a 1 . oie _41 • Needs Shift ! . / . Sprinklers:'- - Fire Alarm: l �. Hoed-8( Duct: -Monitor: • Pre- Fire: Permits: • Occupancy Type: Inspector: F-0)(5.-3 ! 1 Date: //riip. iI • . Hrs.: l �. y $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. jeCall to schedule a reinspection. . Word /Inspection 'Record Form.Doc 1/13/06 • T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS • • CITY OF TUKWILA FIRE .DEPARTMENT • 444 Andover Park East; Tukwila, Wa. 98188 206- 575 -4407 Project: W a `• kC ` ° Id cep Ste, 0 d CtilA Ppift, . ‘'' Type of Insp ion: -c**/ ,._ /044- Address: a U 0 /4 1.-e. 74Suite #: Contact Person: Special Instructions: Pre -Fire: ---- -- - - - -- Phone No.: • Approved per applicable codes. EL9rreciions required prior to approval. COMMENTS: Crv'‘ 0 (C -e -Pte- 4) zit + s' 1' '1 It - f)00 it -Co /37 U 5.6. Stzt 44600) c. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: - Monitor: • Pre -Fire: ---- -- - - - -- Permits: Occupancy Type: Inspector: ILI Ar C-.01-- • I Date: /2_ g . /0 • Hrs.: ' 7 n $80..00 REINSPECTION FEE REQUIRED. You will receive an invoice from • the City of Tukwila Finance Department. CaII to schedule a reinspection. ' -Word /Inspection Record Form.Doc ' 1/13/06 - T.F.D. Form F.P. 113 ;c August 4, 2010 • City of Tu ila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Wayne Johnson S M Stemper Architect 4000 Delridge Way SW #200 Seattle, WA 98106 RE: Correction Letter #1 to Revision #1 Development Permit Application Number D10 -175 North Stair Modification — 2800 Southcenter Mall Dear Mr. Johnson, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D10 -175 W:\Perrnit Center \Correction Letters\2010\D10 -175 Corr Ltr #1 to Rev #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: July 30, 2010 Project Name: SC Mall North Stair Modifications Permit #: D10 -175 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The revision to for the stairway enclosure shall not be permitted as shown. It has been brought to my attention that the "Vacant Space" indicated is intended to be a part of the Seafood City storage warehouse. The installation proposed for the two sets of double doors also indicate the intent for passage of storage items. Path of egress shall not be interrupted by any building element other than a means of egress component. An exit shall not be used for any purpose that interferes with its function as a means of egress. An exit passageway shall not be used for any purpose other than a means of egress. Please provide clarification with notes to indicate the stair enclosure shall not be used for any other purpose than a means of egress. Also specify the true intent for the vacant space. Or its future use. (IBC 1003.6, 1018.1, 1020.1 & 1021.2) 2. Provide the fire resistance rating for the new extended horizontal assembly by door 01. 3. The double doors located within a fire enclosure shall be provided with door coordinators and special flush bolts. If the double door assemblies are to be used, provide specific notes with the manufactures specifications for the door coordinator assemblies. (IBC 1008.1.8.3 #3) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. 1 • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -175 DATE: 07 -28 -10 PROJECT NAME: SC MALL NORTH STAIR MODIFICATIONS SITE ADDRESS: 2800 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMEN S: uilding ivision Public 4',611, 4; lm\ ?l14- cH (Fi - re Prevention Structural Planning Division ll�� Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: Incomplete DUE DATE: 07 -29 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Ii4j Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-26-10 Not Approved (attach comments) DATE: Permit Center Use Only A CORRECTION LETTER MAILED: 8 440 Departments issued corrections: Bldg I< Fire ❑ Ping ❑ PW ❑ Staff Initials: U1 Documents /routing slip.doc 2 -28 -02 • • E I PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -175 DATE: 07 -14 -10 PROJECT NAME: SC MALL NORTH STAIR MODIFICATIONS SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEP RTMENTS: �ing'Ivision Ifc ks °' i /WC, 4--(0 M,(3 4P ire Prevention Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07 -15-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: • TUES /THURS ROUTING: Please Route, Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: DUE DATE: 08-1 2 -10 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PROJECT NAME: 5-C , /'pct U Dw`st. S-1 — "fob PERMIT NO: 1) 10— CTS-- SITE ADDRESS: . $O0 So. c )4,4 b( ORIGINAL ISSUE DATE: 7 v REVISION LOG REVISION NO. _'P , IM �VIIII _s--�- I i� ISSUED �. TE _ _ STAFF INITIALS m�-_�_C_lowl ii, ''_�amis�_�s�m�L 't!y'��•'�����1t,vt�2� E1 _ �a,��pp-.,��T_�_ IIPIIIIIMII , Summ• 0 ,z o�, r ��A„ MV:P'!_W�'Ti1R2_7 - _<r'1�ICk?Bi:�Zi2 �� _.�ECrif 7��. _;;,, Received b : REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED _ STAFF INITIALS ISSUED DATE . STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF .INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED - STAFF INITIALS ISSUED DATE STAFF INITIALS Sununary of Revision: Received by: 41 • City of Tukwila • Steven M Muller, Mayor Department of Community .Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://wim.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: sf// Q7- c 20/ O Plan Check/Permit Number: D10-175 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 • Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Nrry nF mou SEP 08 mg PERMIT CENTER Project Name: North Stair Modification Project Address: 2800 Southcenter Mali Contact Person: /--i ~A/1 'le / Phone Number: Summary of Revision: o/�/L/6x - WI /77 , /c- UoS61-7�ilf SS 7) /Mi=f=tr+ MS0G / -7—t2S Ai /77/ figt 4 /SGGISS/ G's .4�% Sheet Number(s): 1/� "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms - applications on 1ine\revision submittal Created: 8 -13 -2004 Revised: R • • S.M. STEMPER ■ ARCHITECTS A Professional Limited Liability Company September 7, 2010 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Mall Gas Meter Alcove Project No. D10 -117 Attention: Allen Johannessen Listed below is the written response to the `Building Division Review Memo' dated July 30, 2010 which we received on August 6, 2010. The Owner, Seafood City, and ourselves have decided not to implement Owner Revision #1, thus continuing with the previously approved work for this project number. Please see the written responses below. 1. Item #1 — The revision to for the stairway enclosure shall not be permitted as shown. It has been brought to my attention that the "Vacant Space" indicated is intended to be a part of the Seafood City storage warehouse. The installation proposed for the two sets of double doors also indicate the intent for passage of storage items. Path of egress shall not be interrupted by any building element other than a means of egress component. An exit shall not be used for any purpose that interferes with its function as a means of egress. An exit passageway shall not be used for any purpose other than a means of egress. Please provide clarification with notes to indicate the stair enclosure shall not be used for any other purpose than a means of egress. Also specify the true intent for the vacant space. Or its future use. (IBC 1003.6, 1018.1, 1020.1 & 1021.2) • Response — Westfield and Seafood City have decided to not add the double doors that were submitted as part of Revision #1 in an effort to coincide with your concerns listed above. After meeting with Dave Larson and yourself on August 11, 2010 we decided t for permit #D10 -175 and continue with the work on the already approve pans or is perms . As discussed with you, we have submitted for a second permit (D 10 -210) regarding the use of the adjacent vacant tenant space for temporary storage. The permit for D10 -210 was approved by the City of Tukwila on August 30, 2010. 2. Item #2 — Provide the fire resistance rating for the new extended horizontal assembly by door 01. • Response — The owner has decided to not install the double doors and alcoves due to the reasons emphasized in item #1 above. Therefore no corrective action needed. • 3. Item #3 — The double doors located within a fire enclosure shall be provided with door coordinators and special flush bolts. If the double door assemblies are to be used, provide specific notes with the manufactures specifications for the door coordinator assemblies. (IBC 1008.1.8.3 #3) • Response — The owner has decided to not install the double doors and alcoves due to the reasons emphasized in item #1 above. Therefore no corrective action needed. Please accept this written response to your memo, regarding the revision. Please disregard the previously submitted Revision #1 after the permit is issued. If you should have any further questions please feel free to call. Sincerely, 4000 DELRIDGE WAY SW • SUITE 200 . SEATTLE, WA 98106 . 206/624 -2777 . FAX 206/624 -2973 Wayne E. Johnson, ALA S.M. Stemper Architects Cc: Pat Burns, Westfield Encl.. • City of Tukwila letter dated August 4, 2010 • Building Division Review Memo dated July 30, 2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: July 28, 2010 Plan Check/Permit Number: 010 -175 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ® Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: North Stair Modification Project Address: 2800 Southcenter, Seattle, WA 98188 Contact Person: Wayne E. Johnson Phone Number: (206) 624 -2777 Summary of Revision: 1. Change new west door to a pair of doors in lieu of a single door. 2. Add an Additional pair of exit doors from Seafood City including alcove. 3. Relocate existing single door from Seafood to be within alcove to maintain required egress path and door clearances CITY CV TUKWILA IAllt, 28 2010 Sheet Number(s): A1.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: __Entered in Permits Plus on 7 -').-S, — H:\Applications\Fonns- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 Contractors or Tradespeople Pryer Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name B N BUILDERS INC UBI No. 602056687 Phone 2063823443 Status Active Address 2601 4Th Ave Ste 350 License No. BNBUII *990K3 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/23/2001 State WA Expiration Date 9/12/2011 Zip 98121 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTESL913K1 WESTERN STATES LOGISTIX LLC Construction Contractor General Unused 5/8/2009 5/8/2011 Active BASTINB0000J BASTIAN NIELSEN BUILDERS INC Construction Contractor General Unused 9/11/2000 9/7/2001 Archived PURODSI984JN PURODI SYSTEMS INC Construction Contractor Plumbing Unused 6/19/2002 7/2/2010 Expired Business Owner Information Name Role Effective Date Expiration Date BASTIAN, BRAD President 05/23/2001 Bond Amount NIELSEN, JEFF Vice President 05/23/2001 6642084 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 INS CO OF AMERICA 6642084 06/02/2009 Until Cancelled $12,000.0006/05 /2009 4 HARTFORD FIRE INS 52BSBBK5617 01/01/2002 Until Cancelled 06/02/2009 $12,000.0012/04 /2001 3 TRAVELERS CASE SURETY CO 103355900 08/30/2001 Until Cancelled 04/07/2009 $12,000.0009/06 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 WAUSAU UNDERWRITERS INS. CO TBJZ91442966029 09/07/2009 09/07/2010 $1,000,000.00 09/03/2009 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/2008 09/07/2009 $1,000,000.00 09/05/2008 9 WAUSAU BUSINESS INS CO TBKZ91442966027 09/07/2007 09/07/2008 $1,000,000.00 09/05/2007 8 WAUSAU BUSINESS INS CO TBKZ91442966026 09/07/2006 09/07/2007 $1,000,000.0008 /31/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 07/28/2010 WESTFIELD MALL AT SOUTHCENTER TENANT IMPROVEMENT NORTH STAIR MODIFICAT Code Summary CODE SUMMARY: IBC 2006 - INCLUDING WASHINGTON STATE AMENDMENTS FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PERMIT TYPE - TENANT IMPROVEMENT AT EXISTING COVERED MALL BUILDING SITE INFORMATION: MALL COMMONS- EXISTING WOMENS RESTROOM ,ADDRESS: 2800 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -9023 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL SQUARE FEET OF DOOR ALCOVE - 40 SQUARE FEET TOTAL EXISTING SQUARE FEET OF EXIT STAIR - LEVEL I 335 SQUARE FEET REVISED TOTAL SQUARE FEET OF EXIT STAIR - LEVEL I 335 SQUARE FEET OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL EGRESS REQUIREMENTS: EXISTING NO MODIFICATIONS PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) MINIMUM CORRIDOR WIDTH OF 44" PROVIDED THEREFORE ACCEPTABLE FIRE RESISTANCE REQUIREMENTS: DOORWAYS TO EXITS PASSAGEWAYS 51-IALL BE PROTECTED BY I -HOUR FIRE DOOR ASSEMBLY THAT INCLUDES SELF CLOSING DEVICE. - SECTION 402.4.5.1 EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 108. SECTION 106.3.3 EXIST PASSAGEWAY - THE FIRE RESISTANCE RATING OF THE SEPARATION BETWEEN BUILDING AND AN EXIT PASSAGEWAY SHALL COMPLY WITH 1020.1 1020.1 EXIST ENCLOSURE SHALL NOT BE LESS THAN 1 -HOUR WHEN CONNECTING LESS THAN FOUR STORIES- ONLY CONNECTING TWO STORIES THEREFORE 1 -14OUR ASSEMBLY MUST BE MAINTAINED. DOORS IN FULLY OPEN POSITION SHALL NOT REDUCE WIDTH OF REQUIRED DIMENSION BY MORE THAN 1 INCHES. DOOR IS PROVIDED IN AN ALCOVE THEREFORE NOT REDUCING THE REQUIRED EGRESS WIDTH. DOORS SHALL HAVE CLEAR WIDTH OF 32" - 36" WIDE DOOR 16 PROVIDED THEREFORE OK Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT: FIRE ALARM, FIRE SPRINKLER AND ELECTRICAL, SHALL BE UNDER SEPARATE PERMIT TO BE SUBMITTED BY CONTRACTOR. General Notes 1. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE'' ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE NE CONSTRUCTION FOR COMPLIANCE WIN THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LAMER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SNOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND PO NOT WOW EVERY PETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF TINE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER 10. ALL INTERIOR GWB IS B" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GWB. 11. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 12. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 13. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 14. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE TINE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 15. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 16. FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 11. FINISH OF DRYWALL ASSEMBLY SHALL MATCH EXISTING FINISHES AND SHALL BE AT A MINIMUM TAPED AND MUDDED IN ACCORDANCE TO FIRE RESISTIVE REQUIREMENTS MINIMUM OF LEVEL 2 FINISH. 18. CONTRACTOR SHALL RELOCATE LIGHTING, EXIT SIGN, SPRINKLER HEADS AS REQUIRED FOR NEW DOOR AND ALCOVE. 19. CONTRACTOR SHALL FIELD VERIFY THICKNESS OF (E) I -I-1R RATED WALL ASSEMBLY AT STAIR AND SHALL MAINTAIN CONTINUITY OF I -INR RATED ASSEMBLY THROUGHOUT NEW CONSTRUCTION. Scope of Work SCOPE OF WORK SHALL INCLUDE THE PARTIAL DEMOLITION OF THE EXISTING WALL ALONG THE WEST PORTION OF THE STAIR WELL AND THE ADDITION OF A NEW FIRE RATED WALL ASSEMBLY AND DOOR NEW CONSTRUCTION 15 TO INCLUDE A NEW FIRE RATED WALL ASSEMBLY AND DOOR ALL FINISHES ARE TO MATCH ADJACENT FINISHES. Drawing Index ARCHITECTURAL T1.0 TITLE - COVER SHEET A1.0 PLAN, RCP , DETAILS, AND SCHEDULES PLANNING APPROVED e No changes ten be l t°thsse plans without approval frtwn the Planning Division of DCD APProved 804 ityffigLAILip Dots: - 4�1 a 1 A ONS Site Plan FILE COPY Permit No. Q' Plan review approval is subject to errors and omissions. Ao rovai of construction documents does not authorize t tG violation of any adopted code or ordinance. Receipt 01 approved Field Copy and conditions is acknowledged: By e- y � t Date: 11 Lii (0 City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila CTE. Revisions will require Building and ma in new Alan submittal Project Directory WEA SOUTHCENTER, LLC 633 Southcenter Seattle, WA 981138 SENIOR GENERAL MANAGER: ANDREW CIARROCH1 T - 206246.0423 F - 206244.8601 MALL OPERATIONS: PAT BURNS T - 206246.0423 F - 206244.8601 C - 206.186.9011 PBURNS•WESTFIELD.COM ARCHITECT S.M. STEMPER ARCHITECTS, P.L.L.C. 4000 Delridge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2711 (206) 624 -2913 FAX wayneesmstemper.com SEPARATE PERMIT REQUIRED FOR: Mechanical lectrical [Plumbing rat as Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPPMED JUL 2 3 2010 A uote- City of Tukwila BUILDING DIVISION SEAFOOD CITY 2 LEVELS ]11111li 1, bIO 175 Southcenter 833 Sentimental. Parkway 'Nkda, WA., 98188 -2888 208- 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION ANO UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESIGN AND OTHER INFORMARON SHOWN ON THE DRAWMNG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 ISSUE ISSUE DATE: PERMIT SET JULY 15,2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T1.0 SMSA #1022.07 EXTERIOR NORTH PARKING LOT t 10' -0" "NOT AN EXIT" SIGN TO BE LOCATED ON STAIR SIDE OF DOOR VACANT SPACE 1 1 1 1 ci01p I I see. I— I 1 I■ I — 1 1 1 (E) I HR FIRE RATED WALL ASSEMBLY TYPICAL NMI UP STAIR EX_TINGWAZI L 1T0 oErfaL13HEry 1 1 1 1 I 1 1 1 I 1 I P T TY*IC L I I 1 11 11 elel. see. I 1 1 1 I 1 1 1 1 1 I (E)1 HR FIRE RATED WALL ASSEMBLY, TYPICAL 1 A 1 3' -6" FLOOR PLAN (E) 1 HR FIRE RATED WALL ASSEMBLY, TYPICAL t 30' -2" (E) 1 HR FIRE RATED WALL ASSEMBLY ( FIELD VERIFY WALL THICKNESS) 10" METAL STUD FRAMING 5 /8" GWB 1 /4" = 1' -0" SIM. METAL STUD BOX HEADER 1/2" TYP. HOLLOW METAL FRAME AND ANCHORAGE I HR RATED HOLLOW METAL DOOR RE: DOOR SCHEDULE FURNISH AND INSTALL J ) C4 SPRINKLER HEADS AS REQUIRED (E) WALL TO BE DEMOLISHED -i SECTION 1" = 1' -0" EXIT CORRIDOR FROM SEAFOOD CITY 14 GA. METAL STUD BOX HEADER TO BE MADE OF (2) 10005200 -6S (V) AND (2) 600T200 -65 (H) WITH °8 SCREWS AT 12" O.C. AT ALL JOINTS BOTTOM OF SOFFIT s' -011 FIRST LEVEL FF etr) 0' -011 t 10' -0" •1. EXIT GU/5 SOFFIT 1 (E) 1 HR FIRE RATED WALL ASSEMBLY, TYPICAL FURNISH AND INSTAL SPRINKLER HEADS AS REQUIRED SURFACE MOUNTED LICsH": SEE ELECTRICAL • (E) STAIRS AND LANDINGS STAIR S3 -I (E) 1 HR FIRE RATED WALL ASSEMBLY, TYPICAL t 30' -2" EXIT 1 (E) 1 HR FIRE RATED WALL ASSEMBLY, TYPICAL REFLECTED CEILING PLAN 1/4" = 1' -0" HEAD 5 /S" GWB METAL STUD BOX HEADER HOLLOW METAL FRAME AND ANCHORAGE JAMB 5 /8" GU METAL STUD JAMB HOLLOW METAL FRAME AND ANCHORAGE DOOR DETAILS 1 -1/2" = 1' -0" EXIT CORRIDOR FROM SEAFOOD CITY WALL TYPES WALL TYPE 1 (I -HR RATED) UL DESIGN r U -465 - EXISTING 5/8" TYPE X GWB - EXISTING 6" STL. FRAMING AT 16" O.G. - EXISTING 5/S" TYPE X GM LEGEND: EXIT NMI I I - EXISTING DOOR - NEW DOOR - NEW WALL - EXIT SIGN RE: ELECTRICAL - EGRESS PATH DOOR - 1 -HR RATED WALL ASSEMBLY DOOR FRAME TYPES 2'11%E SCHED.Ii_2" H.M. DOOR TYPES ` pEE SCHED.y A (FLUSH) H.M. DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB 01 STAIR WELL A FLUSH 3' -0" x 1' -0" 1 3/4" HM. A HM. 1 HR 4/A1.0 4/A1.0 I 1, 2, 3 02 EXISTING STAIRWELL DOOR A FLUSH PAIR 3' -0" x 1' -0" 1 3/4" HM. A HM. (E) 1-HR - - - - 03 EXISTING STAIRWELL DOOR A FLUSH 3' -0" x 1' -0" 1 3/4" 1-111. A 1411. (E) 1 -HR - - - - REMARKS 1: HOLLOW METAL FRAME TO BE PRIMED FOR PAINT UNLESS NOTED OTHERWISE ABBREVIATIONS FL FR NR FLUSH DOOR FRAME HOLLOW METAL NON -RATED NOTES TO DOOR TYPES 1. PROVIDE LEVER TYPE HANDLES, MOUNTED AT 3S" AFF. AT SPACES SCHEDULED TO BE ACCESSIBLE PER ADA CODE, TYP. 2. SIGN 'NOT AN EXIT" TO BE CENTERED ON DOOR AT 60" AFF 3. SEE HARDWARE GROUP FOR BALANCE OF HARDWARE. NOTES TO FRAME TYPES 1. ALL DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR. HARDWARE GROUP GROUP 1 - GLASS DOOR 01 1 - OVERHEAD SURFACE MOUNTED LCN CLOSER 1 - EXIT DEVICE 3- HINGES (BUTT) 1 SET - SMOKE GASKET, SEALS. 1 - MORTISE CYLINDER LEVER TYPE HANDLES L- SERIES 11 1 - WALL STOP 1 - "NOT AN EXIT" SIGN MIN 6" HIGH RED LETTERS w7t •11 REVIEWED FOR CODE COMPLIANCE APPPfVED JUL 2 3 2010 City of Tukwila BUILDING DIVIf If N RECEIVED JUL 14 2010 PERMIT CENTER Wesdeff Southcenter 633 Sautheenter Parkway Tukwia, WA„ 98188 -2088 208- 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERNCE, IS THE PROPERTY OF THE ARCHITECT AND NAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESIGN MID OTHER INFORMATION SHOWN ON THE ORAWTNG ARE FOR USE ON THE SPECIRED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ISSUE ISSUE PERMIT SET DATE: JULY 15,2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ PLAN, REFLECED CEILING PLAN, DETAILS, AND SCHEDULES A1.0 SMSA #1022.07