Loading...
HomeMy WebLinkAboutPermit D10-205 - TUESDAY MORNING - SHELLTUESDAY MORNING 17720 SOUTHCENTER PY D10 -205 City St Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 3523049005 Address: 17720 SOUTHCENTER PY TUKW Suite No: Project Name: TUESDAY MORNING Permit Number: D10-205 Issue Date: 08/31/2010 Permit Expires On: 02/27/2011 Owner: Name: KIR TUKWILA 050 LLC /KIMCO Address: PROPERTY TAX DEPARTMENT , 3333 NEW HYDE PARK STE 100 11042 Contact Person: Name: DAVID DURR Address: 10310 S TACOMA WY, STE K , LAKEWOOD WA 98499 Contractor: Name: ONEDURR INC Address: 1310 S TACOMA WY - SUITE K , LAKEWOOD WA 98499 Contractor License No: ONEDUI *107C6 Phone: 253 377 -4524 Phone: 253 - 584 -2165 Expiration Date: 03/08/2011 DESCRIPTION OF WORK: CREATING A VANILLA SHELL IN AN EXISTING SHOPPING CENTER. ACCESSIBLE MEN AND WOMENS TOILET ROOMS WILL BE CREATED ALONG WITH AN OFFICE AND BREAK ROOM. Value of Construction: $38,000.00 Fees Collected: $1,288.78 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -10106 D10-205 Printed: 08 -31 -2010 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10 -205 Issue Date: 08/31/2010 Permit Expires On: 02/27/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: Private: Public: LiDate: �c 3� D I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting o permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • •e� •rmance o ork. authorized to sign and obtain this development permit. Signature: � X Date: Print Nam- ���<�G� �. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -205 Printed: 08 -31 -2010 wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3523049005 Address: Suite No: Tenant: 17720 SOUTHCENTER PY TURIN TUESDAY MORNING PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10-205 ISSUED 08/06/2010 08/31/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is doc: Cond -10/06 D10 -205 Printed: 08 -31 -2010 • N wq City of Tukwila ,- sy Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) doc: Cond -10/06 D10 -205 Printed: 08 -31 -2010 • 141[4 iv City of Tukwila Department of Community Development G1 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 27: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 32: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 39: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 41: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 42: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Cond -10/06 D10-205 Printed: 08 -31 -2010 \"'qs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -205 Printed: 08 -31 -2010 • • �J,�,� ►A w4� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htqx/Iwww.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the'flierformance of work. Signature: ,5,4& Print Name: Date: ' 3 - /v doc: Cond -10/06 D10-205 Printed: 08 -31 -2010 CITY OF TUKVIA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Pe It O 1-05 Mechanical Permit No. Plumbing/Gas Permit No. Q ' 1/0 j Public Works Permit No. Project No. i i o t1 U or o ' ce use on Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17720 SouthCenter Parkway Tenant Name: Tuesday Moming Property Owners Name: Mailing Address: Vim Oa 144111 36 3 r i p, 'R lvcI 5 $ellevt, King Co Assessor's Tax No.: 91lee Suite Number: Floor: 1st New Tenant: m Yes ❑ .. No 19404 City LOA' State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 'Devil) T )% -6L.—. Day Telephone: 2- ir 3 . 317 •`f 5-24 Mailing Address: (0 3 1 0 4. �1'�(i�1Ml �ilj'J' /� � &<. � (.04 4g4,9? 11 City State Zip E -Mail Address: da.m-e. elv►ecCOehe pa n¢i)7G • CO NA Fax Number: (2 S >) 9 d' -74f 79 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: O N EDV:Z12- , We- • Mailing Address: 10 310 S • Ti9-ez 4&414- Ll'mq Lt grapy? City State Zip Contact Person: MIIAP -• D U I U., Day Telephone: 7 6 •3) 31'7 —1452# E -Mail Address: &AAQ,.. B'r1 active p u Mi.11 .cD x Number: (73) 4 S'f 7 it 7 Contractor Registration Number: OM DU 1 101 C.44) I Expiration Date: Z Z b /i ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: MBA Architects Mailing Address: 806 North 2nd Street Contact Person: Mike Benjamin E -Mail Address: mgb @mbaarchitects.com Tacoma City State Day Telephone: (253) 752 -9409 Fax Number: (253) 752 -0538 98403 Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H Npplications\Forms- Applications On Line12010 Applications \7 -2010 - Permit ApplicaLon.doc Revised: 7 -2010 bh State Zip Page 1 of 6 i,BUIL1kING PERMIT INFORMATIO11006 -431 -3670 Valuation of Project (contractor's bid price): $ 3g «No Existing Building Valuation: $ Scope of Work (please provide detailed information): Creating a vanilla shell in an existing shopping center. Accessible Mens and Womens toilet rooms will be created along with an office and breakroom. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE ' ROTECTION/HAZARDOUS MATERIALS: P — Sprinklers ❑ Automatic Fire Alarm ❑ None m Other (specify) alteration ' Will ere be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la` Floor 8,400 8,400 0 0 VB M 2"a Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE ' ROTECTION/HAZARDOUS MATERIALS: P — Sprinklers ❑ Automatic Fire Alarm ❑ None m Other (specify) alteration ' Will ere be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER /O�/f AU HORIZED AGENT: Q Signature: /(�V Date: U Print Name: D/D J • Dual` Mailing Address: /0"/P 5. T b70 Date Application Accepted: 0$ Iltk�, Day Telephone: 25 3 37 7 4452* liceVetV 019-- 9( if y7 City State Zip Date Application Expires: Staff Initials: H:\Applications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised. 7 -2010 bh Page 6 of 6 1 • • wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049005 Permit Number: D10-205 Address: 17720 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/06/2010 Applicant: TUESDAY MORNING Issue Date: Receipt No.: R10 -01723 Initials: User ID: WER 1655 Payment Amount: $782.85 Payment Date: 08/31/2010 01:32 PM Balance: $0.00 Payee: ONEDURR PAINTING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 30718 782.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 778.35 640.237.114 4.50 Total: $782.85 PAY MENT 36 ;own doc: Receipt -06 Printed: 08 -31 -2010 Cit,of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 08 -06 -2010 at 16:22:23 08/06/2010 RECEIPT NO: R10 -01519 Initials: JEM Payment Date: 08/06/2010 User ID: 1165 Total Payment: 543.73 Payee: ONEDURR PAINTING, INC. SET ID: S000001406 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D10 -205 PG10 -101 TOTAL: Amount 505.93 37.80 505.93 TRANSACTION LIST: Type Method Description Amount Payment Check 30546 543.73 TOTAL: 543.73 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 TOTAL: 543.73 543.73 YME:T RECEIVED .:. • Date: next inspection. fee must be Cando schedule reinspection. • • •• . Date: rior to next inspection; fee must be Siite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 o PGSject; -ti'.s0 iof 4I1lfL,£, Type of Inspection: r r,t. M c A.�� . Address: 1 9210 Date ailed: Special Instructions: / - ate Wanted: a.m. rft: Requester: Phone No: 2-1' ? Approved per applicable codes. Corrections required prior to approval.. COMiMENT p W ail'Ot!.P; % S4PVW . 7-1‘ tra Es— t1 1-t. t ,+%►rN. rt ,c. t 4QV4 4' i I r Inspecto��.�y j /�/ . AA i\ a ... /IAA • i Date[ /� I. f .......vi �iZ SPECTION F REQUIRE . Prior to next inspection, fee must be d at 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEA • NO. PERMIT NO. Nfr CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ?Dieu: � 1 t� AN(e+14u Type of Inaction: '� AWM 1 Address: Ill Zv .,C�.PR ate Called: Special Instructions: Date Q CD — 1 0 a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. "orrections required prior to approval. COMMENTS: �^ r D/ n1 I_(/ nekicP-kk4c4 Date 7 00 REINSPECTION FE REQUIRED. Pr'or to inspection, fee must be at 6300 Southcenter : lvd., Suite 10 '. Call to schedule reinspection. R cei • t No.: Date: • : ' • • INSPECTION REC Retain a copy with perm INSP"" CITY OF TUKWILA•BUIL-DING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 4312451 PEIigIT NO. D VISION • (206) 431 -3670 Pegject: I v ej,�.... i kt p rn., Type of Inspectiofi : , 1 - 47 Address: Date till ,,r Special Instructions: ' Date Wanted: � j .. r � a.m. Requester: . a Phone No: ?.,. _3 -- 0 9 2,7i Approved pe� applicable codes. RCorrections required prior to approval. /0 • se, : ief1 P - -,A/ A/0 1/47 t. _� a • • ter • • n • ector: / Date: N FEE RE UIRED. rior to ext inspection. fee must be paid a 6300 outhcenter Blvd:: S ,ate 100. Call to schedule reinspection. • • ' 4, INSPECTION NUMBER INSPECTION RECORD: Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 II� Project: 77.4 0... g Asti yy) 0,A,•4, Type of Inspection: Jd' pr i1O 4 if'i /14 / r5.4y- ?J44" r%ia. J Address: 1.772...p Suite #: .. late wy' Contact Person: leea ' Special Instructions: Occupancy Type: Phone No.: 02S0 — 470 r Z SFr© Approved per applicable codes. riCorrections required prior to approval. COMMENTS: lire A:40.1 Needs Shift Inspection: Sprinklers: _ Fire Alarm: Hood & Duct: Perm Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f#15 Date: /o11gjip Hrs.: / y$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. CaII to schedule a reinspection. Word/Inspection Record Form.Doc • 1/13/06 • T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 010 -2-os Y L /0--t PERMIT NUMBERS • CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: n , s�,,y ,,a,t, Type of Inspection: Address: 1 i/-2. o ,5Gp4wY 'Suite #: Contact Person: e -$, Special Instructions: Phone No.: 4 ©G . 7.13 -- 7o 5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: AY - / .44ee C S. a0" y iuv� nr i.vve. 71). C. bei,14-. ,yc , ,»,:•3 /i' / /i/ /.., Irij ji Needs Shift Inspection: • Date: johdtho Hrs.: • Sprinklers: Fire Alarm: //� "'` r_ 3 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A .s3 • Date: johdtho Hrs.: • / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc. 1/13/06 T.F.D. Form F.P. 113 ::' -. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575-4407 Project: hesdc y P'%r #,1,7,3 Type of Inspection: • . ..02 wjc a4Ly J. rt Address: 17720 S C Pre Suite #: v_ • Contact Person: Special Instructions: Phone No.: ' /- 2S.3 - 6Z7-CZ Mg Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: a -� ,ter y ,� J a: °� -� r r_ •�. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood &Duct: - Monitor: Pre -Fire: Permits: Occupancy Type: - Inspector: • . pin ( . bate:. j,1 / LI 110 Hrs.: $80:00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 • :INSPECTION NUMBER INSPECTION.RECORD Retain a copy with permit la4:-"cz"1q3 • - PERMIT NUMBERS • CITY OF•TUKINILA FIRE• DEPARTMENT 444 Andover Park East, Tukwila; Wa. 98188 • 206 -575 -4407 Project: -r—tm,s tAci Fire Alarm: �f Type of Inspection: 5pr :64 k 1., Cove- Monitor: 1I Address: f 1170. Suite #: - -- - -- - - -- -- - 'S G . L Conta Person: osS 'Jerjve et,..• ,Y 4 Special Instructions: Phone No.: . 76 -3 -47 --. '1 I Approved per applicable codes. Corrections required prior to approval. COMMENTS: 5/Ac C o v a l stop . L 4,-4 Vciin Needs Shift Inspection: Sprinklers: f Fire Alarm: �f Hood & Duct: Monitor: 1I Pre -Fire: Permits: Occupancy Type: - - - -- - -- -- - -- - Inspector: _.,. 5`{ Date: alleibo Hrs.: 1.0 n $80.00 REIN PECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 'word /Inspection Record Form.Doc . • • 1/13/06 T.F.D. Form F.P. 113 PERMIT tiri Vag PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -205 DATE: 08/06/10 PROJECT NAME: TUESDAY MORNING SITE ADDRESS: 17720 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: NIA- Pu Ii Works Pu lic Works g AP\ 1.Wc, 8 -.3 -f Fire Prevention Structural A/44 e Planning Division Permit Coordinator II DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete •chi Comments: Incomplete U DUE DATE: 08/10/10 Not Applicable n (0 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route 11, REVIEWER'S INITIALS: Structural Review Required No further Review Required n DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09/07/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople'nter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ONEDURR INC UBI No. 601220754 Phone 2535842165 Status Active Address 10310 S Tacoma Way Ste License No. ONEDUI *107C6 Suite /Apt. License Type Construction Contractor City Lakewood Effective Date 2/26/1990 State WA Expiration Date 3/8/2011 Zip 98499 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status THUNDP'0778L THUNDURR PAINTING Construction Contractor painting /Wallcovering Unused 1/13/1993 5/21/2011 Active ONEDUPS153D1 ONEDURR PAINTING SERVICES Construction Contractor Painting /Wallcovering Unused 3/21/1985 2/1/1990 Archived Business Owner Information Name Role Effective Date Expiration Date DURR, DAVID S Cancel Date 01/01/1980 Amount DURR, TERESA A E 20 01/01/1980 01cg951592 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC 616597 02/01/2002 Until Cancelled $12,000.00 01/10/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 AMERICAN STATES INS CO 01cg951592 02/01/2009 02/01/2011 $1,000,000.00 01/21/2010 19 AMERICAN STATES INS CO 01CG951592 02/01/2008 02/01/2009 $1,000,000.0001 /11/2008 18 AMERICAN STATES INS CO 01AP0961701 02/01/2007 02/01/2008 $1,000,000.00 01/22/2007 17 AMERICAN STATES INS CO 01CG91519210 02/01/2006 02/01/2007 $1,000,000.00 01/05/2006 16 AMERICAN STATES INS CO 01AP096170 -0 02/01/2005 02/01/2006 $1,000,000.00 12/30/2004 15 AMERICAN STATES INS CO 01AP0961709 02/01/2004 02/01/2005 $1,000,000.00 01/09/2003 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/31/2010 TUESDAY MORNING T.I. @ PARKWAY SUPER CENTER TUKWILA, WA x27' Cost Pius 16,8O?sf c Furniture Gall 48,1370Sf 26,252! 000sr !eel) Count 92 0I! G 236; SITE PLAN 1J 11 11111 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. D 10- ?.OS Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation any adopted code or ordinance. Receipt of approve ► F • ; • •y = d t editions is acknowledged' Date 3 B City Of 1iUkwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: ErCethanical [Electrical senumbing Gras Piping City of Tukwila BUILDING DIVISION PLUMBING FIXTURE COUNT CHAPTER 211- PLUMBING SYSTEMS OF THE WASHINGTON STATE BUILDING CODE AMENDMENTS TABLE 2102.1- MINIMUM PLUMBING FIXTURES FOR THE OCCUPANCIES LISTED BELOW, USE 200 SQUARE FEET (18.58 m2) PER OCCUPANT FOR THE MINIMUM NUMBER OF PLUMBING FIXTURES. TYPE OF BLDG OR OCCUPANCY WATER CLOSETS MALE FEMALE LAVATORIES MALE FEMALE GROUP M RETAIL OR WHOLESALE STORES 1:1 -50 1:1 -50 ONE PER 2 WATER CLOSETS PLUMBING FIXTURES CALCULATIONS BUILDING AREA CONTAINS 8,400 5Q. FT 8,400 /200 5F PER OCCUPANT = 42 21 MALE $ 21 FEMALE WATER CLOSETS REQUIRED: 1 MALE, 1 FEMALE LAVATORIES REQUIRED: 1 MALE, 1 FEMALE WATER CLOSETS PROVIDED: 1 MALE, 1 FEMALE LAVATORIES PROVIDED: 1 MALE, 1 FEMALE NORTH Ai N.T.S. \' OCCUPANT LOAD GALLS EGRESS PLAN NO. ROOM NAME CLASSIFICATION AREA (SQ. FT.) FLR AREA / OCCUPANT OCCUPANT LOAD O.L. (ROUNDED UP) 100 RETAIL MERCANTILE - GRADE FLRS. 1058 30 GROSS 235.26 236 101 OFFICE BUSINESS SO 100 GROSS .80 1 102 WOMENS EXMEPT 52 N/A N/A 1 103 MENS EXEMPT 51 N/A N/A 2 104 BREAK ROOM ASSEMBLY 110 15 NET 6 6 105 RECEIVING AREA MERCANTILE- STORAGE, SHIPPING 610 300 GROSS 2.3 3 106 HALL EXEMPT 142 N/A N/A N/A TOTAL FLOOR AREA 8,163 5Q. FT. TOTAL OCCUPANT LOAD 244.36 241 NORTH Aillk N.T.S. \' REVIEWED FOR CODE COMPLIANCE APPROVED AUG 26 2010 City of Tukwila BUILDING DlVisiON TAX PARCEL NO. 2623041011 2623041110 3523041005 LEGAL DESCRIPTION W 140.16 FT OF 51/11/4 OF 5E 1/4 OF SECTION 26 -23 -04 LESS PORTION WITHIN MINKLER BLVD TGW W 140.16 FT OF NW 1/4 OF NE 1/4 OF SECTION 35 -23 -04 LESS 5 430 FT PORTION OF 5E 1/4 OF SW 1/4 - BEGIN NE CORNER TH 5 01 -12 -25 W TO 5E CORNER OF 5W1/4 TH WLY ALONG 5 LINE TO A LINE 6 FEET DISTANT NELY, MEAS AT R/A FROM ELY MARGIN OF SOUTHGENTER PARKWAY TH NWLY ALONG SAID LINE TO POINT WLY OF POINT OF BEGINNING TH ELY TO POINT OF BEGINNING LESS PORTION IN MINKLER BLVD NE 1/4 OF NW 1/4 LY ELY OF CO ROAD LESS 5 430 FT PROJECT TEAM OWNER: NORTHWEST BUILDING SERVICES 8004 55TH AVENUE GT. EAST PUYALLUP, WA 18311 PH. 253 - 848 -5652 FAX 253- 841 -5463 CONTACT: BRETT OFELT ARCHITECT: MBA ARCHITECTS 806 NORTH 2ND STREET TACOMA, N.A. 48403 PH. 253- 152 -4404 FAX. 253- 152 -0538 CONTACT: MIKE BENJAMIN CODE DATA BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY TYPE: AREA: 2001 15C EXISTING VB - SPRINKLERED M 8400 SQ.FT. ZONING: TUG - TUKWILA URBAN CENTER MECHANICAL AND ELECTRICAL TO BE DEFERRED SUBMITTALS FIRE SPRINKLER ALTERATIONS TO BE DEFERRED SUBMITTAL GENERAL NOTES: 1. PROVIDE HANDICAP SIGN AT TOILET ROOM LOCATIONS. (SEE DETAIL A ON SHEET A2.1) OWNER TO PROVIDE EXACT MOUNTING LOCATIONS. 2. ALL DOOR HARDWARE TO BE SINGLE ACTION LEVER RELEASE. 3. CONTRACTOR SHALL PROVIDE HORN STROBES IN ALL TOILET ROOMS PER IBC SECTION 101.1.1.1 4. CONTRACTOR TO VERIFY ALL CONDITIONS AND DIMENSIONS REPRESENTED WITH IN THESE DRAWINGS. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONTINUING WORK THAT MAY BE AFFECTED BY SUCH DISCREPANCY. CONTRACTOR WILL BE RESPONSIBLE FOR ANY WORK DONE AFTER DISCOVERY OF ERROR(S) /OMISSIONS NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. DRAIAIING INDEX T1.0 DOVER SHEET, PROJECT DATA A2.1 EXISTING/DEMO FLOOR PLAN, PROPOSED FLOOR PLAN A2.2 REFLECTED CEILING PLAN, ROOM FINISH SCHEDULES, DETAILS A4.1 INTERIOR ELEVATIONS A4.2 INTERIOR ELEVATIONS PROJECT DESCRIPTION: THIS PROJECT LOCATED AT THE PARKWAY SUPER CENTER 15 INTENDED TO PROVIDE THE NEW TENANT (TUESDAY MORNING) WITH A VANILLA SHELL. UPGRADES INCLUDED N THIS SCOPE OF WORK ARE; REPLACING THE EXISTING TOILET ROOMS WITH NEV ACCESSIBLE TOILET ROOMS. A NEW OFFICE AND BREAK ROOM ARE ALSO BEING CREATED. THE NEW TENANT WILL PROVIDE THEIR OWN T.I. PLANS FOR SUBMITTAL. d0D rn; -�S UM ft Fmiii�y* Fu , A?s7l _ Enker Blvd DIV FULA 4 062010 PERNMtT CENTER ;1.2n ink ter Blvd UP12rd D Ti�land -i3e mkt 0 010104000k.' 001010000a2U 10 t01410 >' Irtemiap � MAP 1)100-- SCALE: N.T.S. 5135 REGISTERED ARCHITE T ICHAEL • NJAMIN STATE OF WASHINGTON These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. .Wa F- Z o tiZo. gm Z W W ▪ 0. O z 2 c W o W o PERMIT SET CONTENTS CODE DATA DRAWING INDEX VICINITY MAP EGRESS PLAN SITE PLAN REVISIONS NO. DATE ITEM PROJECT NO: 10 -018 DATE: 05 AUGUST 2010 DRAWN BY: JB SHEET NO: RESTROOM SIGNS IN/ HANDICAP SYMBOL N.T.S. 1^1ALL TYPES 1 2 t—IcA -e I►H1iii► INI ku ►! rWIRSWImimN� p ut 60 "X56" W.G. CLEARANCE PER 6043.1 1 30 "X48" LAV CLEAR FLOOR SPACE PER 606.2 60" DIAM. WHEELCHAIR TURNING SPAGE PER 304.1 60" DIAM. WHEELCHAIR TURNING SPACE PER 304.1 30 "X48" LAV CLEAR FLOOR SPACE PER 606.2 5/8" TYPE "X" GAB 3 -5/8" METAL FRAMING @ 1e O.G. SOUND BATT INSULATION 5/8" TYPE "X° GAS 5/8" TYPE 'X' GAB 6" METAL FRAMING @ 16" O.G. 3 -5/8" SOUND BATT INSULATION 5/8" TYPE 'X' GAS LEGEND h NT5 WALLS TO BE DEMO EXISTING WALLS NEW WALLS DOOR TO BE DEMO EXISTING DOOR NEW DOOR EXISTING WINDOW ELECTRICAL SYMBOLS NTS F FAN 0 DUPLEX RECEPTACLE OUTLET 110 15" A.F.F. U.N.O. G.F.I. DUPLEX RECEPTACLE OUTLET 110 - GROUND FAULT INTERRUPT m 60 "X56" W.G. CLEARANCE FER 604.3.1 �` '�J i HO• �Nii ',Jip4ti p�iili�'i ' • • �i'`1�P �P �ii�p��0�'i0 OHO• pw tiNt ENLARGED TOILET ROOM PLAN ;t FURRING TO ALLOW \ FLAT WALL SURFACE AND MOUNTING OF GRAB BARS NORTH grak SCALE: 1/2" = 1' -0" \' EXISTING OHD TO REMAIN ISTING DEMISIN ADJACENT TENANT U �1 RECEIVING AREA 105 EXISTING - ELEGTRIGAL PANELS EXISTING FIRE EXTINGUISHER NEW OUTLET (VERIFY LOCATION WITH TENANT) A2.1 FRAME CEILING W/ (MIN) WO 5162 -054 (50KSI) STEEL JOISTS @ 16" O.G. JOISTS MUST MEET 125 lb LIVE LOAD. RETAIL 100 BREAK R 104 mom O st ILA tL.To F MOP SINK Io 1- 0 HOT WATER \ TANK ABOVE (10 GAL. MIN.) 1: EXISTING VCT FLOORING TO REMAIN 2: REPLACE ANY DAMAGED, BROKEN, OR BADLY WORN TILES W/ MATCHING V.T. 3: FLOORS TO BE PROFESSIONALY GLEANED AND WAXED. 4: INSTALL (2) CEILING TYPE POWER POLES. LOCATION TO BE DETERMINED BY A TUESDAY MORINING REPRESENTATIVE. PROPOSED FLOOR PLAN NEW OUTLET S' -4" NEW OUTLET (VERIFY LOCATION WITH TENANT) EXISTING FIRE EXTINGUISHER ING FIRE HOSE 6 EXISTING DEMISING WALL ADJACENT TENANT PROVIDE ELECTRICAL SUPPLY W/ TIMER FOR EXTERIOR SIGN NORTH SCALE: 1/S" = 1' -0" WALL,DOOR, AND CEILING TO BE REMOVED EXISTING SHELVING TO BE REMOVED DM NOTE: ALL FORMER TENANT FIXTURES, SHELVING, DISPLAY, CASH WRAP STANDS, FURNITURE, AND EQUIPMENT TO BE REMOVED NOTE: EXISTING WOOD BRACKETS ON WALLS TO REMAIN. WALL, DOOR, AND FIXTURES TO BE REMOVED Duo -cos REVIEWED FOR CODE COMPLIANCE APPPflVED AUG 26 2010 City ot Tukwila BUILDING I)IVIRICN REMOVE EXISTING SIGNS FROM STORE FRONT AND PYLON BELONGING TO FORMER TENANT. EXISTING / DEMO FLOOR PLAN NORTH AI I SCALE: 1/8" = 1' -0" WIF RECEIVED CITY OF TUKWILA AUG .0a2010 PERMIT CENTER 5135 Fl 'L G. ENJAMIN STATE OF WASHINGTON REGISTERED ARCHITECT These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. .Wa �z co tD W a ca Z 0. Z W W a) ODz� 2 en _�. aa� y • W N' °A V PERMIT SET CONTENTS EXISTING / DEMO FLOOR PLAN PROPOSED FLOOR PLAN LEGEND ENLARGED TOILET ROOM PLAN REVISIONS NO. DATE ITEM PROJECT N❑: 10 -01S DATE: 05 AUGUST 2010 DRAWN BY: .J5 SHEET NO: A2.1 POOR TWES FRAME TWES F.F. SOLID CORE WOOD PAINT GRADE 1/2" MIN. GWB PENETRATION BEHIND FRAME FACES WELDED STEEL STRAP ANCHORS METAL FRAMING / INSUL. (SEE WALL TYPES) 5/8" TYPE X GWB. EA. SIDE 'HOLLOW METAL HEAD /JAMB INTERIOR DETAIL ROOM FINISH SCHEDULE SCALE: 3" = 1' -0" 4 F.F. HOLLOW METAL FRAME NOTE 1: 200q IBC SECTION 1008.1.1 THRESHOLDS: THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.15 INCHES (11.1MM) IN HEIGHT FOR SLIDING DOORS SERVING DWELLING UNITS OR 0.5 (12.1MM) INCHES FOR OTHER DOORS. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50- PERCENT SLOPE). NOTE 1 SCALE: 3" = 1' -0" ELEGTRIGAL FIXTURE KEY NTS F EXIT 12" X 48" SURFACE MOUNT FLUORESCENT (2 TUBE 56W) 24" X 48" SURFACE MOUNT FLUORESCENT (2 TUBE 56W) FAN EXISTING EXIT LIGHT- FILLED AREAS INDICATES LIGHTED SIDE EXISTING EMERGENCY FLOODLIGHT GENERAL NOTES: 1. GENERAL CONTRACTOR RESPONSIBLE FOR COORDINATING ALL ELECTRICAL FIXTURES $ SWITCHING /AO TN OTHER 5UB TRADES (I.E.. - CASEWORK, MEGHANIGAL) AND TO NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. 2. THI5 ELECTRICAL FIXTURE KEY 15 INTENDED TO BE USED A5 A GUIDELINE FOR INTENT AND STYLE PURPOSES ONLY; ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING A COMPLETE ELECTRICAL FIXTURE SCHEDULE INDICATING MANUFACTURER AND PRODUCT NUMBER WITH GUT SHEETS FOR REVIEW AND APPROVAL BY THE ARCHITECT. 3. SEE MECHANICAL FOR HVAC EQUIPMENT / FIXTURE LOCATION. KEY NOTES: ci 5 /5" TYPE X GAS CEILING NO. ROOM NAME FLOOR BASE WAINSCOT NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING REMARKS Mat. Fin. Mat. Fin. Mat. Fin. Height Mat. Fin. Mat. Fin. Mat. Fin. Mat. Fin. Mat. Fin. Height 100 RETAIL -- -- -- -- -- -- -- -- -- -- -- - - /GWB - - /PT - - /GWB - - /PT -- -- -- PATCH $ REPAIR GW5 101 OFFICE 5V -- RB -- -- -- -- GAB PT GAB PT -- PT GWB PT GAB FT 8' -0" PATCH $ REPAIR GWB 102 WOMENS 5V -- ICB -- PLAM -- 4' -0" PLAM /GWB --/FT PLAM /GWB - - /PT PLAM / -- - - /PT PLAM /GWB - - /PT GM PT 8' -0" PATCH 4 REPAIR GM 103 MENS 5V -- ICB -- PLAM -- 4-0" PLAM /GWB - - /PT PLAM /GWB --/FT PLAM / -- --/FT PLAM / -- - - /PT GWB PT 8' -0" PATCH 4 REPAIR GWB 104 BREAK ROOM 5V -- RB -- -- -- -- -- PT -- PT -- PT -- PT -- PT -- PATCH 4 REPAIR GW5 105 RECEIVING AREA -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- PATCH it REPAIR GM 106 HALL -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- PATCH it REPAIR GM ABBREVIATIONS GPT CARPET 5T STAIN EPT EPDXY PAINT ICB INTEGRAL COVE BASE Type 5V SHEET VINYL PT PAINT RB RUBBER BASE 3' -0" X 1' -0" 1 NOTE 1: INTEGRAL COVE BASE (GB) TO BE INSTALLED PER 200q IBC SECTION 1210.1. ICB BASE TO EXTEND UPWARD ONTO WALL A MINIMUM OF 4 INCHES. INTERIOR FINISH SCHEDULE PAINT -1 MANUFACTURER: COLOR: LOCATION: SHERWIN WILLIAMS #5W 1101 FUTON EGG SHELL FINISH WALLS DOOR SCHEDULE NO. DOOR SIZE DOOR TYPE FRAME TYPE FRAME DETAILS REMARKS Type Mat Finish Type Mat Finish Head Jamb Thr. 101A 3' -0" X 1' -0" 1 HM PT A HM PT 2 2 1 W/ DOOR GLOSER 102A 3' -0" X 1' -0" 1 HM PT A HM PT 2 2 1 -- 103A 3' -0" X 1' -0" 1 HM PT A HM PT 2 2 1 -- * ALL DOOR HARDWARE SHALL BE SINGLE ACTION LEVER RELEASE RECEIVING AREA 105 NO CHANGE TO CEILING $ LIGHTING LAYOUT EXISTING HALL EXISTING EMERGENCY LIGHT 106 NO CHANGE TO CEILING $ LIGHTING LAYOUT BREAK RM 104 EXISTING EMERGENCY LIGHT I)— EXISTING EMERGENCY LIGHT EXISTING MECHANICAL SYSTEM TO BE ALTERED TO PROVIDE COVERAGE IN NEW TOILET ROOMS $ OFFICE EXISTING EMERGENCY LIGHT EXISTING EMERGENCY LIGHT EXISTING EXIT MENS EXISTING FIRE SPRINKLER SYSTEM TO BE ALTERED TO PROVIDE COVERAGE IN NEW TOILET ROOMS $ OFFICE EXISTING RETAIL 100 NO CHANGE TO CEILING & LIGHTING LAYOUT CONTRACTOR TO REPAIR EXISTING PLASTIC THAT MAY BE HANGING FROM ROOF DECK. 103 MOMENS 102 OFFICE 101 I F 1 6- EXISTING EMERGENCY LIGHT EXISTING EMERGENCY LIGHT bIo2OS REVIEVVtL) FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 EXISTING EXIT City ofTulsa BUILDING DI �_ ON PROPOSED REFLECTED CEILING PLAN riT NORTHjk SCALE: 1/8" = 1' -0" \' 0 Z��� a W w / U „U] ❑0 z Na, IN • Ce U Zm tri • IN Q ma 1— RECEIVED CITY OF TUKWILA AUG :0 6 2010 PERMIT CENTER 5135 REGISTERED ARCHITECT M • A' c�JAMIN STATE OF WASHINGTON These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. ■Wa ■ 1 z W a al) Z r ca W W Q Ct 0 Z� 2 en I CE � ° CA o W re o M Q N ~ate g PERMIT SET CO NTENTS PROPOSED REFLECTED CEILING PLAN ELECTRICAL FIXTURE KEY KEY NOTES GENERAL NOTES ROOM FINISH SCHEDULE REVISIONS NO. DATE ITEM PROJECT N❑: 10 -018 DATE: 05 AUGUST 2010 DRAWN BY: JB SHEET NO: A2.2 PAINT ABOVE BRACKETS EXISTING EXIT SIGN AND EMERGENCY LIGHT A5 -15 RETAIL 100 GWB PT EXISTING EMERGENCY LIGHT SCALE: 1/4" = 1' -0" / PAINT ABOVE BRACKETS AS 15 PAINT ABOVE BRACKETS GWB PT EXISTING EMERGENCY LIGHT A5 —I5 PAINT ABOVE BRACKETS EXISTING FIRE HOSE ASSEMBLY A5 —I5 PAINT ABOVE BRACKETS A5 -15 PAINT ABOVE BRACKETS A5 —I5 RETAIL 100 PAINT ABOVE BRACKETS A5 -15 EXISTING FIRE EXTINGUISHER EXIT EXISTING EXIT SIGN AND EMERGENCY LIGHT PAINT ABOVE BRACKETS A5 -15 RETAIL 100 EXISTING EMERGENCY LIGHT SCALE: 1/4" = 1' -0" PAINT ABOVE BRACKETS —\ AS 15 PAINT ABOVE BRACKETS A5 -15 PAINT ABOVE BRACKETS AS -15 EXISTING FIRE EXTINGUISHER PAINT ABOVE BRACKETS \A5 -15 EXISTING EMERGENCY LIGHT PAINT ABOVE BRACKETS AS 15 SCALE: 1/4" = 1' -0" D io.os PAINT ABOVE BRACKETS \--A5 15 RETAIL 100 OFFICE 101 SCALE: 1/4" = 1' -0" GINS PT PT 1 RB BASE OFFICE 101 SCALE: 1/4" = 1' -0" GINS PT RB BASEJ / / Z PAPER TOWEL DISPENSER 50AP DISPENSER 2' -6" BREAK RM 104 SCALE: 1/4" = 1-0" BREAK RM 104 SCALE: 1/4" = r BREAK RM 104 SCALE: 1/4" = 1' -0" PATCH AND REPAIR PAINT SCALE: 1/4" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 City of Tukwila BUILDING DIVI,SII1N RECEIVED (CITY OF TUKWILA AUG ,0 d•2010 PERMIT CENTER 5135 elWr/l vIr if C AEL a NJAMIN STATE OF WASHINGTON REGISTERED ARCHITECT These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. 1— —I PERMIT SET CONTENTS INTERIOR ELEVATIONS REVISIONS NO. DATE ITEM PROJECT N❑: 10 -015 DATE: 05 AUGUST 2010 DRAWN BY: JB SHEET ND: A4.1 - o II e m 2' -0" 2-3" 1' -6" BREAK RM 104 SCALE: 1/4" = 1-0" BREAK RM 104 SCALE: 1/4" = r BREAK RM 104 SCALE: 1/4" = 1' -0" PATCH AND REPAIR PAINT SCALE: 1/4" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2010 City of Tukwila BUILDING DIVI,SII1N RECEIVED (CITY OF TUKWILA AUG ,0 d•2010 PERMIT CENTER 5135 elWr/l vIr if C AEL a NJAMIN STATE OF WASHINGTON REGISTERED ARCHITECT These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. 1— —I PERMIT SET CONTENTS INTERIOR ELEVATIONS REVISIONS NO. DATE ITEM PROJECT N❑: 10 -015 DATE: 05 AUGUST 2010 DRAWN BY: JB SHEET ND: A4.1 RECEIVING AREA 105 RECEIVING AREA 105 3' -6" SCALE: 1/4" = 1' -0" GWB PT \ \ 0 0 0 PAINT 4' -&" 5 -3" HALL. 106 INSULATE EXPOSED PIPES TO PREVENT CONTACT WOMEN'S 102 SCALE: 1/4" = 1' -0" (n 0 ('1 r IC5 BASE 1"-q" �% WOMEN'S 102 SCALE: 1/4" = 1' -0" SCALE: 1/4" = 1' -0" WOMEN'S 102 SCALE: 1/4" = 1' -0" i t t / 1 EXIT SCALE: 1/4" = 1' -0" EXISTING ELECTRICAL PANEL PATCH AND REPAIR RECEIVING AREA 105 PAINT 7 WOMEN'S 102 SCALE: 1/4" = 1' -0" ./ 1' 1h ryk, ,vu. SCALE: 1/4" = 1' -0" GWB PT PLAM HALL 106 SCALE: 1/4" = 1' -0" 4' -6" 3' -3" 7, 0 0 / PAINT RECEIVING AREA 105 EXISTING EXIT SIGN AND EMERGENCY LIGHT EXIT 5 -6" MEN 103 SCALE: 1/4" = 1' -0" 9 IGB BASE Tues0 V incsavar46, 'r. t , ni i sZ5u per^ c v, OVA PLuml s£R (3rezt t 1'40"T 'V o S.At_z. MEN 103 SCALE: 1/4" = 1' -0" R -K PLUMBING & HEATING, LLC 11524 Clover Crest Dr. SW LAKEWOOD, WA 98499 i (253) 588 -1228 Fax (253) 534 -3517 0 N r GWB PT 0 0 0 MEN 103 SCALE: 1/4" = 1' -0" 1L N N F IGB BASE -I • / \ 1 INSULATE EXPOSED PIPES TO PREVENT CONTACT KEY NOTES: 0 GOOSENECK FAUCET AND SINK BASIN FGIG 0 WALL MOUNT PAPER TOWEL DISPENSER FGIG. BOBRIGK -5-2621 ® BARRIER FREE (ACCESSIBLE) WATER CLOSET FGIG ® BARRIER FREE (ACCESSIBLE) GRAB BAR (NON -SLIP) FGIG ® 2' -0" X 3' -6" STANDARD MIRROR FGIG 0 SOAP DISPENSER FGIG. BOBRIGK -15-2111 0 TOILET SEAT COVER DISPENSER FGIG. BOBRIGK -B -301 ® TOILET PAPER DISPENSER MODEL # BOBRIGK 5-2888 3/4" TBG PLY WD ON 600 5162 -054 (50KS1) STEEL JOISTS @ 16" O.G. (JOISTS MUST MEET 125 lb LIVE LOAD), 5/8" TYPE 'X' GWB 3 -5/8" METAL STUDS @ 16" 0.C. W/ SOUND BATT INSULATION W/ 5/8" TYPE 'X' GWB EA. SIDE 3 -5/8" METAL BOTTOM PLATE MECHANICALLY FASTENERS @ 24" 0.C. MAX @ ALL NEW WALLS (TYP). NOTE: ALL TOILET PRODUCTS ARE TO BE INSTALLED PER THE IBC, WASHINGTON STATE AMENDMENTS AND IGG /ANSI A111.1 -2003 CODES TO OF WALL SCALE: 1/4" = 1' -0" Rio via-os LEDGER. USE SAME JOISTS AS CEILING FRAMING EXISTING DEMISING WALL OFFICE 101 REVIEWED FOR CODE COMPLIANCE APDPIlVED Mb 2 6 2010 City of Tukwila UILDING DIVIRION G G. RECEIVED CITY OF TUKIMLA AUG .0 6 2010 PERMIT CENTER IC AEL JAMIN STATE OF WASHINGTON These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from MBA Architects is expressly prohibited. These drawings and all prints therefrom remain the property of MBA Architects. II a "7. INN A • Z 4,, iu Ix co 4 CO Zv�,� ct Z W W O Z 2 en Id of aaI- y W w I- 2 4 N O N' 0. ti PERMIT SET CONTENTS INTERIOR ELEVATIONS SECTION REVISIONS NO. DATE ITEM PROJECT N❑: 10 -018 DATE: 05 AUGUST 2010 DRAWN BY: JB SHEET NO: A4.2