Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D10-216 - MACY'S - LOGISTICS - DOOR OPENINGS
MACY'S LOGISTICS 17000 SOUTHCENTER PY 1310-216 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 2623049076 Address: 17000 SOUTHCENTER PY TUKW Suite No: Project Name: MACY'S LOGISTICS Permit Number: D10-216 Issue Date: 08/27/2010 Permit Expires On: 02/23/2011 Owner: Name: FEDERATED DEPT STORES INC Address: ATTN: TAX DEPARTMENT - SHF , 7 W 7TH ST 45202 Contact Person: Name: JIM BOONE Address: 17000 SOUTHCENTER PY , TUKWILA WA 98188 Contractor: Name: G L Y CONSTURCTION INC Address: PO BOX 6728 , BELLEVUE WA 98008 Contractor License No: GLYCOI *01809 Phone: 206 - 300 -6979 Phone: 425 451 -8877 Expiration Date: 09/30/2010 DESCRIPTION OF WORK: ENLARGE (3) DOOR OPENINGS BY ONE FOOT IN HEIGHT WITH STRUCTURAL REINFORCING Value of Construction: Type of Fire Protection: Type of Construction: $9,500.00 Fees Collected: $464.52 International Building Code Edition: 2009 Occupancy per IBC: 0025 * *continued on next page ** doc: IBC -10 /06 D10 -216 Printed: 08 -27 -2010 City oilI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D 10 -216 Issue Date: 08/27/2010 Permit Expires On: 02/23/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: A)J17 Date: V - )--1`t (/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thelerformance oaf y rk. I am authorized to sign and obtain this development permit. Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -216 Printed: 08 -27 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049076 Address: Suite No: Tenant: 17000 SOUTHCENTER PY TUKW MACY'S LOGISTICS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10 -216 ISSUED 08/16/2010 08/27/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 D10 -216 Printed: 08 -27 -2010 le • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: �l/t --�----�� Date: cL (/ 6-9 iz -c Print N —2 7--( doc: Cond -10/06 D10 -216 Printed: 08 -27 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. c • ... Mechanical Permit No Plumbing /Gas Perm=it No. Public Works Periniit'No. Project No. . (For:office. se only) . Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 17 0 $Du ceHf¢� Tenant Name: y s i s -h ` 5 Property Owners Name: Ma tl M u- p King Co Assessor's Tax No.: '2Jj i2)(14 ^ b\ 01 (p ` et k "',.. " Suite Number: Floor: New Tenant: ❑ Yes 51..No l v g4 1' Mailing Address: State City Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: aec N Mailing Address: l 70 D (-Cr h c t K `hp" f`t n �c"et. Li E -Mail Address: Tr ky. , Boone C y 5 , Day Telephone: .-0G -300 g777 City State Zip Fax Number: G j'7 5 2.- 11 GENERAL CONTRACTOR INFORMATION - - • (Contractor Information. for Mechanical •(pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip ARCHITECT OF RECORD.— All.plans must be siampedby Architect of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD — All-pians.must be stamped by Engineer of `Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H- Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application. doc Revised: 7 -2010 bh Page 1 of 6 • • BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ G%3 N Existing Building Valuation: $ Scope of Work (please provide detailed information): E f 4. P. et a 3 Jo. v Of,. 1 Ny s Sao 7 1 n h Will there be new rack storage? ❑ Yes No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square'Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Vis No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: a Sprinklers B, Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes a No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst'Floor 2' Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached. Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Vis No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: a Sprinklers B, Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes a No If 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: 0 ,ft-, 300 -e Day Telephone: Date: 69. - 1 — ( 206 —300 —G 979 Mailing Address: 1 7 000 5, c,1 ll c Je Par It 4 y 1-1464-• 1414A City State Zip Date Application Accepted: OM to Date Application Expires: {le ,41 H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Staff Initials: j6 1 Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049076 Permit Number: D10-216 Address: 17000 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 08/16/2010 Applicant: MACY'S LOGISTICS Issue Date: Receipt No.: R10 -01696 Payment Amount: $283.30 Initials: WER Payment Date: 08/27/2010 08:41 AM User ID: 1655 Balance: $0.00 Payee: JIM BOONE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 011624 ACCOUNT ITEM LIST: Description 283.30 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 278.80 640.237.114 4.50 Total: $283.30 �MYMENT 1prt.FivFn doc: Receiot -06 Printed: 08 -27 -2010 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049076 Permit Number: D10-216 Address: 17000 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 08/16/2010 Applicant: MACY'S LOGISTICS Issue Date: Receipt No.: R10 -01595 Payment Amount: $181.22 Initials: JEM Payment Date: 08/16/2010 03:34 PM User ID: 1165 Balance: $283.30 Payee: JIM BOONE, MACY'S TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 059911 ACCOUNT ITEM LIST: Description 181.22 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 181.22 Total: $181.22 PA'YMENT RECFIVED doc: Receiot -06 Printed: 08 -16 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit /0-'2/6 PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 142" • . 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: //MC I Co /.017/e c Type of Inspection: . iC /A/4V. • . * Address: Pee Date Ca rd - -- 4 Special Instructions: • • _ _ Date Wanted: . Requester: Phone NO: CV 0 ‘ —76/0 -7.47Y:7 9 Approved pet applicable codes. .1:Corrections required prior to approval. COMMENTS: SA Aiein A rMT t".%••-- • 'I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be . . • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. RiP"RSINZO-r1' 5 Lt cipss..:%—•:::44.`"c4r1.4c L. Walla+ • S.- 1 • • • ....I.V...NSWetti:411081...raVri.. 4••■••• ni • ..=.1MTSVii. 01 -03 -2011 Citv '1 Jim Haggerton, Mayor Departme- : t of Co- % : mu pity Development Jack Pace, Director JIM BOONE 17000 SOUTHCENTER PY TUKWILA WA 98188 RE: Permit No. D10 -216 17000 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 02/23/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 02/23/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ALQ Bill Rambo Permit Technician File: Permit File No. D10 -216 6300-Southcenter Boulevard, Suite #100 © Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 • Jim Haggerton, Mayor Department of Community Development Jim Boone 17000 Southcenter Py Tukwila, WA 98188 RE: Incomplete Letter #1 Development Permit Application D10 -216 Macy's —17000 Southcenter Py Dear Mr. Boone, Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 16, 2010 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, ifer Marshall it Technician Enclosures File: D10 -216 W: \Permit Center \Incomplete Letters \2010\D10-216 Incomplete Ltr #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 r Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: August 17, 2010 Project Name: Macy's Logistics Permit #: D10 -216 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide specifications for "Special Inspections" related to the steel and epoxy bolt applications. (IBC Chapter 17) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. 110 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -216 DATE: 08/23/10 PROJECT NAME: MACY'S LOGISTICS SITE ADDRESS: 17000 SOUTHCENTER PY Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Tding Division I. Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 74, Comments: Incomplete DUE DATE: 08/24/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route IA, Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/21/10 Approved ❑ Approved with Conditions Not Approved (attach comments) u Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2- 28-02 0 PERM T COM COPY.' PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -216 DATE: 08/16/10 PROJECT NAME: MACY'S LOGISTICS SITE ADDRESS: 17000 SOUTHCENTER PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued PAR ,MENT Bui •ing Divisn N Public Works v`3■ gtot �•��ti� Fire Prevention Lo Structural t\iti ®12'1• I Planning Division I'I ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08/17/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: j j .i LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ►`1 Fire ❑ Ping ❑ PW ❑ Staff Initials: M� TUES /THURS ROUTING: Building Please Route n Structural Review Required 1 1 No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 09/14/10 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D10-216 ® Response to Incomplete Letter # 1 E Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Macy's Logistics 17000 Southcenter Py CRv op AUG 2 3 2010 13ERMIT CENTER Summary of Revision: Pre) Phone Number: ? - O 3 & - -69 1110.i y r e ire -e 114 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: i;tz Entered in Permits Plus on \ applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name G L Y CONSTRUCTION INC UBI No. 578078500 Phone 4254518877 Status Active Address Po Box 6728 License No. GLYCOI'01809 Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 9/29/1999 State WA Expiration Date 9/30/2010 Zip 980080728 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status GALLLI'337CF GALL LANDAU YOUNG CONST CO IN Construction Contractor General Unused 2/6/1967 9/30/1999 Archived HARVAEC978LT HARVARD ESTATE CONSTRUCT LLC Construction Contractor General Unused 6/30/2003 12/28/2009 Expired Business Owner Information Name Role Effective Date Expiration Date YOUNG, FRANK N JR President 05/01/1975 Bond Amount ANDERSON, ROGER L Vice President 05/01/1975 6361244 HARDY, VAN Vice President 05/01/1975 KILCUP, LEROY C Vice President 05/01/1975 ST PAUL FIRE /MARINE INS CO Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 INS CO OF AMERICA 6361244 09/30/2005 Until Cancelled $12,000.00 09/29/2005 6 ST PAUL FIRE /MARINE INS CO JX4513 09/30/2001 09/30/2005 512,000.00 09/21/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 27 NATIONAL FIRE INSURANCE COMPAN 2086884539 09/30/2008 09/30/2010 $1,000,000.00 09/28/2009 26 VALLEY FORGE INS CO 2086884539 09/30/2006 09/30/2008 $1,000,000.00 09/24/2007 25 VALLEY FORGE INS CO 2086884539 09/30/2005 09/30/2006 $1,000,000.0009 /29/2005 24 ARCH INS CO 71PKG3616401 09/30/2004 09/30/2005 $1,000,000.0009 /29/2004 23 ARCH INSURANCE COMPANY 71GPP1968000 10/30/2003 09/30/2004 $1,000,000.00 10/30/2003 22 ST PAUL FIRE & MARINE INS CO KK08400373 09/30/2003 10/31/2004 51,000,000.00 10/03/2003 https: // fortress .wa.gov /lni/bbip /Print.aspx 08/27/2010 SOUTHCENTER BLVD S 168TH STREET MACY'S DISTRIBUTION CENTER BUILDING DOOR OPENING MODIFICATIONS ON FOLLOWING SHEETS APPLY TO NO MORE THAN SIX (6) EXISTING LOADING DOCK DOOR OPENINGS ON THIS BUILDING FACE COORDINATE EXACT LOCATIONS WITH OWNER CORE DRILL A 3 "0 HOLE AT CORNER PRIOR TO CUTTING EXISTING CONCRETE WALL APPROX. PLAN NOT TO SCALE NORTH PORTION OF WALL TO REMAIN STOP SAW CUT11NG AT THIS POINT. DO NOT OVERCUT. PORTION OF WALL TO BE REMOVED SAWCUT DETAIL SCALE = NO SCALE REVISIONS No changes shall be de amain to the scope of 'work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal l r n,I may include additional plan review fees. STEEL CHANNEL - 3 SIDES PER DETAIL S4 EXISTING WALL PANELS AT SOUTH WALL OF LOADING DOCK 0 !� 4 0v 0 CONCRETE WALL PANEL SAWCUT AND REMOVE PORTION OF EXISTING WALL PER DETAIL S3 1' -0" (1' -2" MAX) SHORE PORTION OF WALL TO BE REMOVED PRIOR TO PERFORMING SAWCUT CONFIRM WITH OWNER EXISTING - VERIFY IN FIELD 10' -0" MAX (EXISTING - VERIFY IN FIELD) WALL ELEVATION SCALE = NO SCALE NOTE: IN ACCORD WITH IBC SECTION 1704, OWNER IS TO ENGAGE A QUALIFIED SPECIAL INSPECTOR. STEEL FABRICATION AND WELDING IS TO BE INSPECTED PER IBC SECTION 1704.3. POST- INSTALLED ANCHORS ARE TO BE INSPECTED IN ACCORD WITH ICC REPORTS AND TO VERIFY COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. FILE COPY Permit No., D1O x.1lO Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize i E°: \jblation of any adopted code or ordinance. Receipt r ` approved Field py and conditi is acknowledged. t 7— 20 f OW Of TUkwlla BUILDING DIVISION C8x11.5 WITH 5/8 "0 A36 THREADED ROD 0 2' -0" OC. MITER CUT AND BUTT WELD CHANNEL AT CORNERS. GRIND SMOOTH. EPDXY EMBED THRU HOLE IN CHANNEL WITH PUDDLE WELD AT 2' -0" OC TYP. GRIND SMOOTH. (SIMPSON SET -XP EPDXY OR EQUIVALENT) OPENING REINFORCING SCALE = NO SCALE cmoMtJ► AUG 2 3 2010 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED AUu 5 2010���Q tme- CityofTukwila BUILDING rnvi nw INCOMPLETE �1 O — LTR #_I_ 2.1 L.L W z W U z 0 I- D CO VJ 0Q w j `c/) U y • D 21— z W i 0 0 0 02070, DLR Group, Inc., a Washington corporation. ALL RIGHTS RESERVED.