HomeMy WebLinkAboutPermit D10-247 - WESTFIELD SOUTHCENTER MALL - BEAUTY WORKS - LANDLORD PORTIONBEAUTY WORKS LANDLORD PORTION 182 SOUTHCENTER MALI. D10 -247 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 182 SOUTHCENTER MALL TUKW Suite No: Project Name: BEAUTY WORKS - LANDLORD PORTION Permit Number: D10-247 Issue Date: 10/18/2010 Permit Expires On: 04/16/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WY SW #200 , SEATTLE WA 98106 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Contractor License No: BNBUII*990K3 Phone: 206 624 -2777 Phone: 206 382 -3443 Expiration Date: 09/12/2011 DESCRIPTION OF WORK: LANDLORD BUILD OUT OF NEW MALL STORE FRONT FOR FUTURE TENANT IN EXISTING MALL Value of Construction: $44,000.00 Fees Collected: $1,436.29 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -10/06 D10 -247 Printed: 10 -18 -2010 City o�i'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10 -247 Issue Date: 10/18/2010 Permit Expires On: 04/16/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: { 0 n 1� I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complies. , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the erfo ance of work. I am authorized to sign and obtain this development permit. .:r 1"" I Signature Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -247 Printed: 10 -18 -2010 osm City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 9202470010 Address: Suite No: Tenant: 182 SOUTHCENTER MALL TUKW BEAUTY WORKS - LANDLORD PORTION Permit Number: Status: Applied Date: Issue Date: D10-247 ISSUED 09/07/2010 10/18/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 12: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) doc: Cond -10/06 D10 -247 Printed: 10 -18 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: hN,://www.ci.tukwila.wa.us 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Maintain fire extinguisher coverage throughout. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -247 Printed: 10 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htux//www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: mAti-21 Print Name: 71-A Date: l i 2, ? C( doc: Cond -10/06 D10 -247 Printed: 10 -18 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup:ihvi vtv. ci. tuktvila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2c/ "-' jb Z3 ST Site Address: l r� 2 $� C %���%����•• --- %n��/ Suite Number: L ° d Floor: 1 --� Tenant Name: I,.I•ES( 1EZ_b• -• �E $' W'( vOYAgy New Tenant: ❑ Yes X.. No Property Owners Name: (44ff41' 3o u C4 L r'EP--_• Mailing Address: $OV F City Name: 4YNc' _10.0-1q014 Mailing Address: '{oOo 14.4Ar 4A.1 p ki State Zip Day Telephone: 206- (,2y 2-777 E -Mail Address: I.4_(k l- H Q- S 1.4 --rEM 1' - • CAD N•t Company Name: Ih l+t/A- cepa (v City State Zip Fax Number: 2.0(• t,2.34 - 217 " iI IN • Mailing Address: : ^nntprt P.=rson: E -Mail Address: Contractor Registration Number: City ray Telephone: Fax Number: Expiration Date: State Zip Company Name: S .1`() . 2C ---C+ q E22 Mailing Address: /1OOC- .i L -Ili K W Ski 4` 2 "Eik-TrUe 14 / k q 81 Co City State Zip Day Telephone: 2©C • (c 75-1 • 2_7 7 7 Fax Number: 20 G • 6,.z-t 3 Contact Person: E -Mail Address: WI l-4E _So(II- t:NL Company Name: A Mailing Address: Contact Person: E -Mail Address: Q.WpplicationsTorms- Applications On Line'3 -2006 - Permit Application.doc Revised' 9 -2006 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 Valuation of Project (contractor's bid price): $ �y odd Existing Building Valuation: $ Scope of Work (please provide detailed information): L/ /G•L� - U7 D� sl! Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. ‘ 3, 72-7 8y9Yn I IT B s 2B M PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If `yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Spri ers Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of ammable, combustible or hazardous materials in the building? ❑ Yes ■ I No If "yes', attach list of materials and storage locations on a separate 8-I/2'' x II " paper including quantities and Material Sry ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Wpplications\Fomm- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: signature: 114,0e Lam` Date: a V/C.) Print Name: 144AYN-IE -E t J O.F4-4SD►` Day Telephone: 2 '6 • 6 2y 277 7 Mailing Address: ‘7"0 00 p&'Z,,e. /64/f ��}i .c.16/10 c& t# Ge/0 .5/p�� City State Zip Date Application Accepted: l21 lv1114 Date Application Expires: ogl01li1 Staff Initials: Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-247 Address: 182 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/07/2010 Applicant: BEAUTY WORKS - LANDLORD PORTION Issue Date: Receipt No.: R10 -02091 Initials: User ID: Payee: JEM 1165 Payment Amount: $872.25 Payment Date: 10/18/2010 10:28 AM Balance: $0.00 BNBUILDERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 54026 872.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 867.75 640.237.114 4.50 Total: $872.25 doc: Receiot -06 Printed: 10 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-247 Address: 182 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/07/2010 Applicant: BEAUTY WORKS - LANDLORD PORTION Issue Date: Receipt No.: R10 -01764 Initials: User ID: JEM 1165 Payment Amount: $564.04 Payment Date: 09/07/2010 12:34 PM Balance: $872.25 Payee: S.M. STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15609 564.04 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 564.04 Total: $564.04 03A1303E1 doc: Receiot -06 Printed: 09 -07 -2010 • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING IVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188.. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj t: La( - — R — a -VZ - T, •e Yof Inspe�ctiioon::: n,'r` � -1 1.3 14- J_,:.._. Address: • iAZ se. VV\tPtk" Date Called: Special Instructions: Date Wanted: 1 - t k — l ‘ , am. P.m. Requester: Phone No: "/ Oa. 11A -663 if 121Apprcived per applicable codes. Corrections required prior-to approval. COMMENTS: a2r,v, :k t k 0 -4e IC: Ai X,r/ Date: SPECTION FEE REQ IRED. Prior to next inspection, fee must be • at 6300 Southcenter lvd.. Suite 10 . Call to schedule reinspection. 9 ».- INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Aect: ` A' P►■ lt tj U L Type of Inspection: `14 Ad re t� /f - t SG. J Date CCalhed . Specia Instructions: 1 iti Catf1) Pa *trA V° °� Date Wanted: / i -rr 1 r re") _ r • P.m. Requester: • Phone No: MApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1 4 • linsP LI REI PECTION FEE REQUIRED. Prior to pai , 6300 Southcenter Blvd :. SUite 100. ~i i I:/ea. Date: if J/1 ►7) ext inspection, fee must be 11 to schedule reinspection. `W' 6...^...e,+M_J xwi;''..4".i,3�;.... . t2i7Y' v:% R4�' a.. 4 .1..V..?.k.C,b"R"A {i`?:�C'S"t2b stlikk.�`.40t,4te- .4Y! a+G'.Y.,S:-sv i!: P. nti'+x'4 ..a. , "+J.'eA•_wa:rtY'.�2x.a!rxx*�':i aY.....Mr_..�v...:.z,a.- Y.sw'n aW R.v}!S.' 6.• I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East; Tukwila, Wa: 98188 206 -575 -4407 Project: ` A...- LAU \- S T- e of In- ection: -Y t/ ,iJP+L Address: S . i 4 C0 uite #: Contact Person: Special Instructions: Phone No.: roved per applicable codes. Corrections required prior to approval. COMMENTS: r {r-e - (0 04-( -- -D Needs Shift Inspection : Sprinklers: - Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: Inspector t F...7•t, s e .. Date :. /2_ • G /o Hrs.: / n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 II PEaT` ►`C:i,-Y PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -247 DATE: 09/07/10 PROJECT NAME: BEAUTY WORKS - LANDLORD PORTION SITE ADDRESS: 182 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS BGilitin ivisio Public Works A*pc qn —(b F re Prevention Structural Sit PM' 4/0 Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 09/09/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/07/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople PSer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name B N BUILDERS INC UBI No. 602056687 Phone 2063823443 Status Active Address 2601 4Th Ave Ste 350 License No. BNBUII *990K3 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/23/2001 State WA Expiration Date 9/12/2011 Zip 98121 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTESL913K1 WESTERN STATES LOGISTIX LLC Construction Contractor General Unused 5/8/2009 5/8/2011 Active BASTINB0000J BASTIAN NIELSEN BUILDERS INC Construction Contractor General Unused 9/11/2000 9/7/2001 Archived PURODSI984JN PURODI SYSTEMS INC Construction Contractor Plumbing Unused 6/19/2002 7/2/2010 Expired Business Owner Information Name Role Effective Date Expiration Date BASTIAN, BRAD President 05/23/2001 Bond Amount NIELSEN, JEFF Vice President 05/23/2001 6642084 on Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 INS CO OF AMERICA 6642084 06/02/2009 Until Cancelled $12,000.0006/05 /2009 4 HARTFORD FIRE INS 52BSBBK5617 01/01/2002 Until Cancelled 06/02/2009 $12,000.0012/04 /2001 3 TRAVELERS CAS & SURETY CO 103355900 08/30/2001 Until Cancelled 04 /07/2009 $12,000.00 09/06 /2001 Assignment of Savings Information No records found for the previous 6 year period urance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 ZURICH AMERICAN INS CO g(a380504400 09/07/2010 09/07/2011 $1,000,000.0009 /07/2010 11 WAUSAU UNDERWRITERS INS. CO TBJZ91442966029 09/07/2009 09/07/2010 $1,000,000.00 09/03/2009 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/2008 09/07/2009 $1,000,000.00 09/05/2008 9 WAUSAU BUSINESS INS CO TBKZ91442966027 09/07/2007 09/07/2008 $1,000,000.00 09/05/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 10/18/2010 WESTFIELD MALL AT SOUTHCENTER TENANT STOREFRONT 182 SOUTHCENTER Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK IN PREPARATION FOR FUTURE TENANT. SITE INFORMATION: TENANT SPACE 600 TENANT ADDRESS: 182 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -9023 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: 1,925 SP. TOTAL REVISED SQUARE FEET: 1,925 SF - NO ADDITIONAL TENANT SQUARE FEET AS PART OF THIS WORK OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD (TABLE 1004.1.1): OCCUPANCY LOAD FACTOR - 30 SF/ 1,925 / 30 = 64 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 11 IS 49. (TABLE 1015.1) OCCUPANCY LOAD 15 64 THEREFORE TWO EXITS REQUIRED. TWO EXITS ARE PROVIDED THEREFORE OK MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED THEREFORE ACCEPTABLE EGRESS WIDTH - 64 (2) = 12.8 INCHES - PAIR OF 36" WIDE DOORS SHALL BE PROVIDED AT MALL STOREFRONT AND NEW EXIT DOOR TO BACK OF HOUSE CORRIDOR IS 36" WIDE - THEREFORE OK TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 250 - THEREFORE OK SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR ENTRANCE TO NE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WITHIN TENANT SPACE 16 LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.4.5.1 WHERE DOORWAYS t0 EXITS PASSAGEWAYS SHALL BE PROTECTED BY I -HOUR FIRE DOOR ASSEMBLY THAT IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 15.4.83. SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL General Notes 1. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE, ARCHITECT WILL WAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO E3E RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SNOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DET,4ILS 81-1OWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE, AS THOSE DRAWN FOR SIMILAR CONDITIONS. S. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER. 10. ALL INTERIOR GWB IS I" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GIUB. II. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E- 2A -1013C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS 51-1ALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. I1. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. IS. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. I. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. Scope of Work SCOPE OF WORK SHALL INCLUDED THE LANDLORD BUILD OUT OF TENANT IMPROVEMENT TO AN EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER IN PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: - CONSTRUCTION OF NEW TENANT MALL STOREFRONT ALONG TWO FRONTS CONSTRUCTION OF NEUTRAL PIERS AT TENANT MALL STOREFRONT Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET A1.0 FLOOR PLAN, WALL SECTION, AND ELEVATIONS A1.1 DETAILS Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING MPROVEMENTS kS 154 i S 153rd St =, Lyans' Black,_ REVISIONS No changes shall be made to the seem of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: dachanical Electrical umbing teas Piping City of Tukwila Bi.xii, DIWG DIVISION Project Directory WEA SOUTHCENTER, LLC 2800 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER: ANDREW CIARROCI-II T - 206246.0423 F - 206244.8601 MALL OPERATIONS: PAT BURNS T - 206246.0423 F - 206244.8601 C - 206186,9011 PBURNSeWESTFIELD.COM ARCHITECT S.M. STEMPER ARCHITECTS, PLL.C. 4000 Delrldge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2111 (206) 624 -2913 FAX waYnsesmsteintt Y Permit No. b.LO» 2'/117 Plan review approval is subject to errors and omissions, pp oval of construction documents does not authorize i is violation of any adopted code or ordinance. Receipt c:' approved Feld Copy and conditions is acknowledged: By Date: 1° > l c'� City Of lbkwila BUILDING DIVISION Site Plan REVIEWED FOR CODE COMPLIANCE APDINIVED SEP152010 A-s u - City of Tukwila BUILDING rfl !ITN mervyrrs 2 LEVELS ° EXISTING JCPenney 3 LEVELS CITYOFIUKWILA SEP 0 71010 PERMIT CENTER pto 211 WsiIiek( Southcenter 633 Southeaster Parkway Tukwila, WA., 96188-28N 206 - 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECPS NAME, ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAVANG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624 -2973 SCOTT TW EMP' R STATE OF ' ASHINGTON z w w(i) >z 0 O _ I-- U I- 0 z -J 0 u) LLp O< (i) Q z z w ISSUE ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA #1022.12 TOP OF STOREFRONT 15' -61111 LEASE LINE_\ f TOP OF STOREFRONT 14' -4" ALUMINUM BREAK METAL SHAPE ABOVE STOREFRONT 3%" METAL STUD FRAMING AND GM - PAINT LEVEL 4 FINISH DEMO (E) FINS BOTTOM OF MULLION 10' -0" ALUMINUM STOREFRONT FRAMIN WITH GLAZING FINISH FLOOR 0' -0" (E) BULKHEAD ALUM. STOREFRONT FRAME GLASS ENTRY DOORS - SEE SCHEDULE HARDWARE - SEE SCHEDULE STOREFRONT SECTION 1/2" = 1' -0" BOTTOM OF MULLION 101 -0" METAL STUD FRAMING AND GWB NEUTRAL PIER - PAINT LEVEL 4 FINISH 1/2" ALUM. REVEAL (E) 1/2" ALUM. REVEAL TO REMAIN FINISH FLOOR 01_011 WEST ELEVATION 1 12" HIGH STONE TILE BASE - OFCI 1 /4" = 1' -0" A 1 ALUM. STOREFRONT FRAMING WITH 3 /a" GLAZING - TEMPERED 1 ALUMINUM BREAK METAL SHAPE AT BULKHEAD - MATCH STOREFRONT PAIR OF GLASS ENTRY DOORS RE: SCHEDULE dle 3' -111 ole TYP EXISTING MALL CONCOURSE BULKHEAD (ABOVE) 2 A1.1 DEMO (E) SPACE L FINS IN TENANT (E) STEEL COLUMN TO REMAIN VAC PTE ANT I00 (E) STEEL COLUMN TO REMAIN 3'-1" y LEASE LINE TYP 62' -S" (E) TENANT DEMISING WALL TO REMAIN (E) E VACANT SPACE NO WORK THIS AREA (E) DOOR AND ALCO TO REMAIN (E) TENANT DEMISING WALL TO REMAIN (E) STEEL COLUMN TO REMAIN 16' -2" 15' -6"" TOP OF STOREFRONT BOTTOM OF MULLION 101 -0" FINISH FLOOR 01 -0" 4w Z I1 J FLOOR PLAN 1/4" = 1' -0" ALUMINUM STOREFRONT FRAMING WITH %" GLAZING - TEMPERED (0 ALUMINUM BREAK METAL SHAPE AT BULKHEAD - MATCH STOREFRONT PAINTED GWB LEVEL 4 FINISH DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES _ FIRST FLOOR HEAD JAMB THRESH 100 COMMON MALL - RETAIL AREA N/A GLASS PR 3' -0" x 10-0" I/2" GLASS N/A N/A NR. 2,3 2,3 2,3 1 2, 3, 4, 5 101 VACANT SPACE - CORRIDOR EXISTING 3' -0" x T -0" I -HR 1 REMARKS ABBREVIATIONS 1. EXISTING DOORS ARE TO REMAIN - NO MODIFICATIONS TO DOORS OR FRAMES AL ALUMINUM 2: FURNISH AND INSTALL TILE TO MALL CONCOURSE TILE TO LEASE LINE FL FLUSH DOOR 3. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS MEETING ALL REQUIREMENTS FOR GLASS FR FRAME DOORS INCLUDED ADJACENT BORROWED LITES. HM HOLLOW METAL 4.. PULLS TO BE STAINLESS STEEL NR NON -RATED 5. DOORS TO HAVE SIGN (I" 1-11G1-1 LETTERS) LOCATED ABOVE DOORS WITHIN VACANT SPACE STATING "THIS STOR STOREFRONT DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" WD DOOR WOOD SOUTH ELEVATION 1/4" = 11 -0" HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER (CRL) 2 PRS. 1" DIA, IS" BACK TO BACK PULLS (CRL GLASS MOUNTED STRAIGHT) 2 QTY. DEAD BOLT FLOOR RAIL LOCK (CRL DOOR FLOOR RAIL LOCK) 2 QTY. CYLINDER (CRL MORTISE KEYED CYLINDER) FINISH OF HARDWARE AND STILES SHALL BE BRUSHED STAINLESS STEEL MALL STOREFRONT STOREFRONT DESCRIPTION - EXTRUDED ALUMINUM STOREFRONT - KAWNEER TRIFAB 450 13/4" WIDE ET 4" DEEP FRAMING - SILL SHALL SE 6)" HIGH - MULLION SHALL BE 4" WIDE - HEAD SHALL BE 4" WIDE - JAMBS SHALL BE 4" WIDE - FRAME FINISH SHALL BE ALUMINUM - BLACK - GLAZING SHALL BE MIN. 3 /S" THICK - CLEAR TEMPERED GLASS PER HEIGHT AND GLAZING REQUIREMENTS 31 -1" TYP ■ NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. WALL TYPES SHALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS NOTED OTHERWISE IN WALL TYPES. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MIN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LMES PRIOR TO CONSTRUCTION ANY DESCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1 CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA 12" HIGH STONE TILE BASE - OFCI WALL TYPE ASSEMBLY -1 -Vs" GWB - 6" METAL STUDS AT 16" O.C. -%GWB PAINT GWB LEVEL 4 FINISH TYPICAL REVIEWED FOR CODE COMPLIANCE APD fVED RECEIV��pp Sl=f 5 2010 CIN OF BILA SFP 0 7 2010 City ®f Tukwila PERMIT CENTER BUILDING nnnsiBIV iitstfleff Sou thcenter 633 Southeaster Parkway lbkwla, WA., 96168 -2068 206 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 624 -2973 MPROVEMENTS TENANT STOREFRONT ISSUE z 0 U 0 (1) J 0 Q ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN WALL SECTION ELEVATIONS AND DETAILS A1.0 SMSA #1022A 2 E) ADJACENT TENANT TOREFRONT TO REMAIN .EASE LINE II (E) STONE TILE BASE TO REMAIN DEMO (E) FINS AT MALL CONCOURSE BULKHEAD STOREFRONT AND NEUTRAL PIER STONE TILE BASE - OFCI 21 -611 (E) ADJACENT TENANT NEUTRAL PIER TO REMAIN (E) TENANT DEMISING WALL TO REMAIN a r ALUM. STOREFRONT WITH GLAZING - TYP. NEUTRAL PIER DETAIL 1 1/2" = 1' -0" 3g /e" METAL FRAING AND GLUE. LEVEL 4 FINISH BOTH SIDES ALUMINUM BREAK METAL SHAPE AT BULKHEAD 3 %I' METAL FRAING AND GWB. LEVEL 4 FINISH BOTH SIDES ALUMIMUM STOREFRONT FRAMING WITH GLAZING 35/e" METAL MD FRAMING WITH GWB EACH PAINT - LEVEL �— 4 FINISH DEMO (E) FINS AT (E) BULKHEAD - TYPICAL O ALUMINUM STOREFRONT FRAMING WITH GLAZING TYPICAL BULKHEAD DETAIL 1 1/2" = 1' -0" (E) BULKHEAD LEASE LINE ALUM. STOREFRONT FRAME WITH GLAZING 34" THICK GLAZING - TYP. 4" LEASE LINE STOREFRONT DETAIL 1 1/2" = 1' -0" ALUMINUM BREAK METAL SHAPE ,AT BULKHEAD 354" METAL FRAING AND GWB. LEVEL 4 FINISH BOTH SIDES ALUMINUM STOREFRONT FRAMING WITH GLAZING 34" THICK GLAZING - TYP. 4" 1„ — BACKER ROD AND CAULK EACH SIDE - TYP. LEASE LINE w LU ALUM. STOREFRONT WITH GLAZING STOREFRONT DETAIL 1 1/2" = 11 -0" DEMO (E) FINS AT (E) BULKHEAD - TYPICAL ALUMINUM BREAK METAL SHAPE AT BULKHEAD (E) BULKHEAD ALUMINUM STOREFRONT FRAMING WITH GLAZING BULKHEAD DETAIL AT DOORS 1 1 /2" = 1' -0" 3/? METAL STUD FRAMING AND GWB LEVEL 4 FINISH - TYPICAL 6" METAL STUDS AND GWB. PAINT - LEVEL 4 FINISH %s" THICK GLAZING - TEMPERED LEASE LINE ALUM. STOREFRONT FRAME WITH GLAZING STOREFRONT DETAIL 1 1/2" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPPfVFD Shi 15 2010 City of Tukwila BUILDING DIVISION aTVOREu► SEP 0 7 2010 PERMITCENNTER Wesdeff Sou th cen ter 633 Southo.nt.r Parkway lUkria, WA., 98188 -2888 206- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF DIE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME, ALL DESIGN AND OTHER INFORMATION SHOWN ON THE ORAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624 -2973 4220 I* REGISTERED 1 Pr ATE OF c � lri W Z cn W U w Z � w � Op Cn 2 v z Q z0 _< W CD � < O j �� � ¢ W zQ � z 1— F-ILLI W ISSUE ISSUE DATE: PERMIT SET SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ STOREFRONT DETAILS A1.1 SMSA #1022.12