HomeMy WebLinkAboutPermit D10-254 - WESTFIELD SOUTHCENTER MALL - ARDEN B - LANDLORD PORTIONARDEN B
LANDLORD PORTION
680 SOUTHCENTER MALI.
D10-254
City PTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DEVELOPMENT PERMIT
Parcel No.: 9202470010
Address: 680 SOUTHCENTER MALL TUKW
Suite No:
Project Name: ARDEN B - LANDLORD PORTION
Permit Number: D 10 -254
Issue Date: 10/18/2010
Permit Expires On: 04/16/2011
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name: WAYNE JOHNSON
Address: 4000 DELRIDGE WY SW #200 , SEATTLE WA 98106
Contractor:
Name: B N BUILDERS INC
Address: 2601 4 AV STE 350 , SEATTLE WA 98121
Contractor License No: BNBUII *990K3
Phone: 206 624 -2777
Phone: 206 382 -3443
Expiration Date: 09/12/2011
DESCRIPTION OF WORK:
LANDLORD BUILD OUT OF EXISTING TENANT SPACE - INSTALL NEW EXIT DOOR AND DEMISING WALL
Value of Construction: $8,900.00 Fees Collected: $433.01
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: IIB Occupancy per IBC: 0019
* *continued on next page **
doc: IBC -10/06
D10 -254 Printed: 10 -18 -2010
City ATukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #l00
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number:
Issue Date:
Permit Expires On:
D10-254
10/18/2010
04/16/2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0
Flood Control Zone:
Hauling: N Start Time:
Land Altering: Volumes: Cut 0 c.y.
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Akc7
The granting of this permit does not pr
construction or the performance of work.
Size (Inches): 0
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
Date:
Public:
Non - Profit: N
Public:
1:(00,2
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit.
Signature: 1 k "— / Date: 1 °/ 1 l 1 a
Print Name:
14,6■D i 6 (.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IBC -10/06
D10 -254 Printed: 10 -18 -2010
•
�J�w 4 ►Vq� City of Tukwila
De P artment of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: ht0://www.ci.tukwila.wa.us
Parcel No.: 9202470010
Address:
Suite No:
Tenant:
680 SOUTHCENTER MALL TUKW
PERMIT CONDITIONS
ARDEN B - LANDLORD PORTION
Permit Number:
Status:
Applied Date:
Issue Date:
D10-254
ISSUED
09/08/2010
10/18/2010
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
11: ** *FIRE DEPARTMENT CONDITIONS * **
12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
doc: Cond -10/06
D10 -254 Printed: 10 -18 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
22: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinlder heads. (IFC 901.4)
23: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
26: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06
D10 -254 Printed: 10 -18 -2010
•
C City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature: 1 .L4se. \ 7
Print Name:
Date: k'/ I g
ordinances governing
or local laws regulating
doc: Cond -10/06 D10 -254
Printed: 10 -18 -2010
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
httr,: -- ipt -rip. ci. tuka pila. rva. us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
��/ _ King Co Assessor's Tax No.: 2.6 �3c Q - l oz.S
Site Address:
‘' 80 K //7G4 V'2!2 /Lf,4LL_- Suite Number: 2-S0 Floor: ( T
Tenant Name:_ ESM] ,b. New Tenant: ❑ Yes X.No
Property Owners Name: (4E C JO u'-1-1 ( LWEL� -.
Mailing Address: 2 g0C -N l= tt.iA. gS/88
City State Zip
Name: ILK -64E •Jc>.fh�4 oc 4
Mailing Address: L{OOO imp 14.4P-- "/t /a
City State Zip
Fax Number: 2D(• (,2J -I - 2/-7
Day Telephone: (2.. DG. 42.y 2777
E -Mail Address: kt A1Yi.1e- Q— S fc\ --rtW► Ip ey.... . (p µ-t
Company Name: f..( k - -f S ML
Mailing Address:
r,,,,_ „•, Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
Company Name: 5.1`(1.
Mailing Address: CIOOc) ■EL(t1.F LAW 1,4A g8[O(c,
State Lip
Day Telephone: 2€::•(.. • 424 2-7 7 7
Fax Number: 2c, 6 • 6.2 'j. 2 -7
Contact Person: lruik'{
E -Mail Address: 144-7AJ6s e-6/v/ `S'` 7h pfd . Ca M
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
by Engineer of Recor
Q: Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
Valuation of Project (contractor's bid price): $ 1101111111D gjliOO Existing Building Valuation: $
Scope of Work (please provide detailed information): `.4-A-74 D /24 AU /411 L'U% Of
47,1-/ lirAsaraimwar-
4 d-/ /5A►i ,. 4- L-
/S /, id* Le-
Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required.
46 3 72.7
Zy/ 68 g
9yen
31 5
f
2i
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
4
Lot Area (sy ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Cowpacl:
Will there be a change in use? ❑ Yes No If "yes ", explain:
Handicap:
FIRE PROTECTION /HAZARDOUS MATERIALS:
Spri ers ! Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of am►n`able, combustible o�ardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material etv Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: \Applications\Fonns- Applications On Line\.3 -2006 - Permit Application.doc
Revised: 9-2006
bh
Page 2 of 6
i
rmits as thisppftica
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED�
Signature:
Date:
;VOL)
Print Name: IA(AYP-IE Er ,.1Okil -4S tLE Day Telephone: 2 "6 • 2V% 277 7
Mailing Address: (O00 p&' .,0e-/464 14-/"P'" 9 - a SL L/r -' /A ' S /De-,
City State Zip
Date Application Accepted: LO1? ` 0 D
Date Application Expires: I
I S
Staff Initials: /
/ (
Q:\Applications\Fonns- Applications On LineO -2006 - Permit Application.doc
Revised: 9-2006
bh
Page 6 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 9202470010 Permit Number: D10-254
Address: 680 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 09/08/2010
Applicant: ARDEN B - LANDLORD PORTION Issue Date:
Receipt No.: R10 -02093
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $264.20
Payment Date: 10/18/2010 10:34 AM
Balance: $0.00
BNBUILDERS, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 54027 264.20
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100 259.70
640.237.114 4.50
Total: $264.20
doc: Receiot -06 Printed: 10 -18 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 9202470010 Permit Number: D10-254
Address: 680 SOUTHCENTER MALL TURIN Status: PENDING
Suite No: Applied Date: 09/08/2010
Applicant: ARDEN B - LANDLORD PORTION Issue Date:
Receipt No.: R10 -01774
Initials:
User ID:
JEM
1165
Payment Amount: $168.81
Payment Date: 09/08/2010 11:36 AM
Balance: $264.20
Payee: S.M. STEMPER ARCHITECTS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 15610 168.81
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 168.81
Total: $168.81
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 09 -08 -2010
•
INSPECTION RECORD
Retain a copy with permit
INSPE ON NO. PERMIT NO.-
CITY OF TUKWILA BUILDING DIVISION •
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
i _f1 )C0—
Type of Inspection:
''t r..l_er ia..
.
Address: •
i(49 0 M Pr
(
Date Called:
Special Instructions:
.
Date Wanted:
1- -1(- -1
(
a.m.
Requester:
Phone No:
Approved •per applicable codes.
COMMENTS:
Corrections required prior to approval:
.4.
Date:
SPEETION FEE REQUI „g D. 'Prior. o next inspection, fee must be
at 6300 Southd'enter $lv Suite 0. Call torschedute reinspection.
p' b.
L244 ':. •ne. a..-.e-"aa'Ru. x 'a'• - sue a,;,f_.. • -' .r'r.a• :pram :a�rR- ,oath••. 'G'�•'
•
INSPECTION NO.
INSPECTION RECORD
Retain .a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd:,: #100, Tukwila: WA 98.188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
( to (
Type of Inspection:
4N
Address:
Date Called:
Special Instructions:
Date Wante
1 0
1•0
m
Requester:
Phone No:
Approved per applicable codes:
COMMENTS:
ElCorrections required prior to approval.
•
•
Fl R • PECTION FEE RE( UIRED. Prior/ o next inspection. fee mustbe
• t 6300 Southcenter lvd.. Suite 00: Call to schedule reinspection...
ir•n .t.s rss • . • laiw.ka:. . r•r :-Ye:d!`r:: if*L . r i.►. •+. =�y+6k�r.. :N Jo -..�G Yr xi. -.=.. _n
rrival4Prt..*;"*NUA,A.A.OA.W4ilie. 441W** es.404.4".0144,' „ #011,V,..„At .A014,`"41:4,0 1P.,,V, 1,41 tr, d' 4.4•A .1gZliaZ 111*'.*,'. it*, 10A A0,444,' 6,75,51 1,0,01
2
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project: p
Atede n
Type of Inspection:
Address: 6 it> 3-, c, 41 414...
Suite #:
Contact Person:
Special Instructions:
41.
Phone No.:
Approved per applicable codes.
Corrections required prior to approval. .
COMMENTS:
Sprinklers:
Fire Alarm:
.; Ir..1 vp_...&,,,.
• , •.........
•,,-, -
r,t tk, A,„, ,„ „
PreFire:
Permits:
'"'• 0.'1:,1:" '11Pr"..ilL . :,:
it t. rift'441.i -5-t4re.-7-
fi.) "nr) icgs!'" Ster4 1 401....-.) rite. _,AR; '''' - „ - •''- •
...'-!. 41f•ti5'.`' ■.o':
„: 4,Zt.,).• •
ii.,., ' .4., ,:. ''''•:,::::1!-,. ..-
/ e) fAi: 6, , Cp-wise-/-ei .lak..,e*,,,,)
p .. ..,_ •
, ', - • ...1.1",,,,,,
.
................_ . _ . - - - - - . ••• ': . ste:-.7-77'rlior-
: •Att...
, • • ''''.', ' '`'.4...:4",09t-
• .? . , • • .:.!_,.7.01-
• • -., - .
-•••-•••-- , ... r ,•rt I • . ,..,
-.•..* ,.4...*-47.-.' 7.' ,,,-.., - l' ...,1V0
'''IR'-'1•111.: • -Nig • '41111.e. .
. •
-.....: - ... - , ..• .- •,* l''
•
-- ---
6 • .r
- - — • .
'
• .
..• - - -.. . •
yr.
1
..
_
,.
••
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
PreFire:
Permits:
Occupancy Type:
Inspector: PM 5 .,-' -
I Date: iijopi. .
Mrs.:
/
$80.00 REINSPECTION FEE REQUIRED. Ylou will receive an invoice from
e City of Tukwila Finance Department. ,Call to schedule a reinspection.
Word/Inspection Record Form.Doc
. 1/13/06
•-• „
T.F.D. Form F.P. 113
4.0444 44,14v"M1U4 °ti'k44PV.44 ..44;44,:h^',' *1.1
INSPECTION NUMBER
1 aY ,41003 ONOLASNI N! ` v4444..0,0Atae.V 'R4' '4T,,Vm44244Mtim JrJM4k4"WAti J *r»<44}4'i$4444.6"64 art «1,« kMinU UV4ro'l, 'i.7,0 l+
Ittizesktattia
INSPECTIONRECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWIL - AFIRE DEPARTMENT
444 Andover Park East; Tukwila, Wa. 98188 206- 575=4407
Project:
Pia 3 f Po ig
Sprinklers:
Type of Inspection: g.vuoc
Address: boo c. c _ v
Suite #:
LL
Contact Person:
`Special Instructions:
Occupancy Type:
Phone No.:
nApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
/1/4-)-e �-e 1 C
I.A1 0 4 (7,S7 1 C
-;
Needs Shift Inspection:
Sprinklers:
_
Fire Alarm :
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
1
;,-
Date: It / el ,/r,
Hrs.: (
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
r PERMIT COOK, COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -254 DATE: 09/08/10
PROJECT NAME: ARDEN B - LANDLORD PORTION
SITE ADDRESS: 680 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
D PART ENTS:
Bui ing Divis'o 0
Pllic Works
Fire Prevention
Structural
L'
sc' N /A' 61-1D
Planning Division
u Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments: 777���►►►
Incomplete
DUE DATE: 09/09/10
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 10/07/10
Approved Approved with Conditions n Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name B N BUILDERS INC UBI No. 602056687
Phone 2063823443 Status Active
Address 2601 4Th Ave Ste 350 License No. BNBUII'990K3
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 5/23/2001
State WA Expiration Date 9/12/2011
Zip 98121 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
WESTESL913K1
WESTERN STATES
LOGISTIX LLC
Construction
Contractor
General
Unused
5/8/2009
5/8/2011
Active
BASTINB0000J
BASTIAN NIELSEN
BUILDERS INC
Construction
Contractor
General
Unused
9/11/2000
9/7/2001
Archived
PURODSI984JN
PURODI SYSTEMS
INC
Construction
Contractor
Plumbing
Unused
6/19/2002
7/2/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
BASTIAN, BRAD
President
05/23/2001
Bond Amount
NIELSEN, JEFF
Vice President
05/23/2001
6642084
ation
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
INS CO OF
AMERICA
6642084
06/02/2009
Until Cancelled
$12,000.0006/05
/2009
4
COARTFORD FIRE INS
52BSBBK5617
01/01/2002
Until Cancelled
06/02/2009
$12,000.00
12/04/2001
3
TRAVELERS CAS &
SURETY CO
103355900
08/30/2001
Until Cancelled
04/07/2009
$12,000.0009/06
/2001
Assignment of Savings Information No records found for the previous 6 year period
urance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
12
ZURICH
AMERICAN INS
CO
g1a380504400
09/07/2010
09/07/2011
$1,000,000.0009
/07/2010
11
WAUSAU
UNDERWRITERS
INS. CO
TBJZ91442966029
09/07/2009
09/07/2010
$1,000,000.00
09 /03/2009
10
WAUSAU
BUSINESS INS
CO
TBKZ91442966028
09/07/2008
09/07/2009
$1,000,000.00
09/05/2008
9
WAUSAU
BUSINESS INS
CO
TBKZ91442966027
09/07/2007
09/07/2008
$1,000,000.0009
/05/2007
https://fortress.wa.gov/lni/bbip/Print.aspx
10/18/2010
WESTFIELD MALL AT SOUTHCENTER
TENANT IMPROVEMENT
680 SOUTHCENTER
Code Summary
CODE SUMMARY:
- WASHINGTON STATE BUILDING CODE
- WASHINGTON STATE AMENDMENTS
- 2009 INTERNATIONAL BUILDING CODE
- 2009 INTERNATIONAL MECHANICAL CODE
- 2009 INTERNATIONAL FIRE CODE
- 2009 UNIFORM PLUMBING CODE
- 2009 WASHINGTON STATE ENERGY CODE
- 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE
FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT.
MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT
ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT
PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT.
TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT.
THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK IN
PREPARATION FOR FUTURE TENANT.
SITE INFORMATION:
TENANT SPACE 260
TENANT ADDRESS:
680 SOUTHCENTER
TUKWILA, WA 98188
TAX PARCEL NUMBER:
262304 -9023
ZONING USE:
TUC - TUKWILA URBAN CENTER
TENANT IMPROVEMENT SUMMARY:
TOTAL EXISTING SQUARE FEET:
3,821 5F.
TOTAL REVISED SQUARE FEET:
3,504 SF
OCCUPANCY GROUP:
WESTFIELD MALL - M - COVERED MALL
OCCUPANCY LOAD (TABLE 1004.1.1):
OCCUPANCY LOAD FACTOR - 30 SF/
3,504 / 30 = 111
EGRESS REQUIREMENTS:
PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN
OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) OCCUPANCY LOAD IS 111
THEREFORE TWO EXITS REQUIRED. TWO EXITS ARE PROVIDED THEREFORE
OK
MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED THEREFORE
ACCEPTABLE
EGRESS WIDTH - 111 (2) = 23.4 INCHES - PAIR OF 36" WIDE DOORS SHALL
BE PROVIDED AT MALL STOREFRONT (BY TENANT) AND NEW EXIT DOOR TO
BACK OF HOUSE CORRIDOR IS 36" WIDE - THEREFORE OK
TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER
SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS
THAN 250 - THEREFORE OK
SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED
MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR
ENTRANCE TO THE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE
TO EXITS FROM WITHIN TENANT SPACE 16 LESS THAN 200 FEET THEREFORE
OK
FIRE RESISTANCE REQUIREMENTS:
SECTION 402.4.5.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE
PROTECTED BY 1-HOUR FIRE DOOR ASSEMBLY THAT 16 SELF CLOSING BY
SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.483.
SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE
PARTITION IN ACCORDANCE TO SECTION 109.
CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR
STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT
HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON
ADJACENT TENANTS DEMISING WALL
General Notes
I. ALL WORK TO BE PEED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES
HAVING JURISDICTION OVER THE WORK
2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE
BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
IMMEDIATELY.
3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE
CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE
EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS
WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE
CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES.
4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND
ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES
TRUE, LEVEL, PLUMB AND SQUARE.
5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED
DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS.
6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN
CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST
THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL.
1. DETAILS SHORN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOUIN. DETAILS OF
CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAIN FOR SIMILAR CONDITIONS.
8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND L=ANDSCAPING FROM DAMAGE. CONTRACTOR TO
REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS-ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT.
9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING,
INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO
VERIFY SEQUENCE OF WORK WITH OILNER.
10. ALL INTERIOR GLUES IS i" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON
PLANS. SEE NOTE FOR WATER RESISTANT GWB.
11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GLUES IN ALL TOILET ROOMS, WAREWAN-I AND WET AREAS.
12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK
13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION.
14. PROVIDE ONE TYPE 5E- 2A -10BC FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE,
15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED
PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS.
16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND
FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE
SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL.
11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES.
18. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY
WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS.
19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED.
20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS.
Scope of Work
SCOPE OF WORK SHALL INCLUDED THE LANDLORD
BUILD OUT OF TENANT IMPROVEMENT TO AN EXISTING
VACANT SPACE WITHIN WESTFIELD MALL AT
SOUTHCENTER IN PREPARATION FOR FUTURE TENANT.
WORK 61-IALL INCLUDE, BUT NOT BE LIMITED TO:
- CONSTRUCTION OF NEW TENANT DEMISING WALL.
- DEMOLITION OF EXISTING WALL AT TENANT SPACE
AND BACK OF HOUSE CORRIDOR
- CONSTRUCTION AND INSTALLATION OF EXIT DOOR TO
BACK OF HOUSE CORRIDOR
Drawing Index
ARCHITECTURAL
TO.0 TITLE - COVER SHEET
A1.0 FLOOR PLAN, WALL SECTION, AND DETAILS
Separate Permits
THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT
SUBMITTED BY CONTRACTOR OR TENANT:
- INTERIOR TENANT IMPROVEMENT
- FIRE ALARM
- FIRE SPRINKLER
- MECHANICAL
- ELECTRICAL
- PLUMBING
Vicinity Map
_151. St
53rd Ave S
I 1 S 152nd P[ 'I, �T
\S_154n1 St
tr jl - S 153rd Ste
-_
So Tullwflk
Ufht�, Park
'�trry9/ w4
Crysttrt •
sprli i;ts
Park
S 1.59th`St;
both;5t j `II`-
yS 161st St
+• 1,
til
F
L _Suutiicenter l lall
Ij
5.164th St
167th St I
y
We- ! /lelAT, T {
rputllCCittSr .
- WESTFIELD AT
SOUTHCENTER
� e
Evans Black L
Baker Blvd
LL
Strander Blvd •a
1
S 166th Ln
IL/1
la
TukvOla
Pond
J.__Trcck Or
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SEPARATE PERMIT
REQUIRED FOR:
!S Mechanical
IrElectrical
terP�,tmbing
as Piping
City of Tukwila
BUILDING DIVISION
Project Directory
WEA SOUTHCENTER, LLC
2800 Southcenter
Seattle, WA 98188
SENIOR GENERAL MANAGER:
ANDREW CIARROCHI
T - 206246.0423
F - 2062448601
MALL���tION�:
PAT BURNS
T - 206246.0423
F - 2062448601
C - 206 186.9011
PBURN5 UJESTFIELD.COM
ARCHITECT
SM. STEMPER ARCHITECTS, PLL.C.
4000 Delrldge Way SW Sulte 200
Seattle, Washington 98106
CONTACT: WAYNE JOHNSON, PROJECT MANAGER
(206) 624 -2111
(206) 624 -2913 FAX
waynessmstemper.com
FILE CtPY
Permit No. b ill''Simi
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
By
Date: 6 l t. 8/ 1-0
City Of Tukwila
BUILDING DIVISION
Site Plan
TENANT SPACE
680 SOUTHCENTER
REVIEWED FOR
CODE COMPLIANCE
PDRMED
SEP 15 2010
A:3-
City of Tukwila
BUILDING DIUIs,G m
mervynrs
2 LEVELS
NORDSTROM
J3 LEVELS
RECEIVED
CITY OF TIIKWILA
SEP 0 8 '1010
PERMIT. CENTER
plo.-2g4
Wesifle[C
Southcenter
633 Southo.nt.r Parkway
lUkvlq WA., 98188 -2888
206 -2411 -0423
WESTFIELD DESIGN &
CONSTRUCTION
11601 Wilshire Boulevard, 11th
Floor Los Angeles, California
90025 -1748
Telephone 310 478 4456
Facsimile 310 478 4468
THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS ME PROPERTY OF THE
ARCHITECT AND MAY NOT DE REPRODUCED WMOUT ME ARCHITECrS
PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S
NAME. ALL DESIGN AND OTHER INFORUAION SHOWN ON THE DRAWNG ARE
FOR USE ON ME SPECIFIED PROJECT ONLY AND SHALL NOT BE USED
OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(200) 624-2777 • FAX (206) 624 -2973
W
I--
Z
W
U
2
H
0
to
I-
<
J
J
0
w
LL
w
ISSUE
ISSUE
PERMIT SET
DATE:
SEPT. 3, 2010
PROJECT ARCHITECT
WEJ
PROJECT MANAGER
WEJ
TITLE - COVER
SHEET
T0.0
SMSA #1022.13
(E) ELECTRICAL
PANEL
TO REMAIN
(E) COMM., DATA,
PHONE PANELS
TO REMAIN
ADJACENT
TENANT SPACE
, *1
'—(E) SIDEWALK—N
(E) DOOR TO
REMAIN
1
o?
+ 61.511
± 8' -4"
(E) DOOR T
REMAIN
+ IS' -2 1/2"
TENANT
DEMISING
WALL
M
(V
(E) WALL TO
REMAIN
(E) DOOR TO
REMAIN
r
VACANT TENANT
SPACE TO BE BUILT
OUT BY TENANT
UNDER SEPARATE
PERMIT
± 26' -3"
ADJACENT
TENANT SPACE
(E) EXIT
CORRID
(E) TENANT DEMISING
WALL
(E) TENANT
DEMISING WALL
TENANT STOREFRONT
BY TENANT
FLOOR PLAN
ADJACENT
TENANT SPACE
1/8" = 1' -0"
(E) ELECTRICAL PANEL TO
BE RELOCATED
NEW DOOR AND FRAME
RE: SCHEDULE
(E)WALL ASSEMBLY
TO BE DEMOLISHED
NSTALLATImN-
1
(E) ELECTRICAL PANEL TO REMAIN
RELOCATE (E) ELECTRICAL PANEL TO ALLOW
FOR REQUIRED CLEARANCES AT DOOR SURFACE
MOUNT PANEL ON LINISTRJT FRAME
1-
X
w
9
74-
�r
PARTIAL FLOOR PLAN
(E) HM FRAME AND WALL
ASSEMBLY TO BE DEMOLISHED
(E) DOOR AND FRAME
TO BE DEMOLISHED
1/2" = 1' -0"
(E) ELECTRICAL METERS
TO REMAIN
(E) EXIT CORRIDOR ---\\
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
DOOR
STYLE
SIZE
W x H
THK.
DOOR
MATL.
FRAME
MATL.
RATING
DETAILS
HDWR
GROUP
NOTES
FIRST FLOOR
HEAD
JAMB
THRESH
100
TENANT SPACE - EXIT CORRIDOR
N/A
FLUSH
3'-0" x T-0"
13/4 I
HM
HM
I- HR
3
4
-
1
2, 3, 4, 5,
REMARKS ABBREVIATIONS
1. EXISTING DOORS ARE TO REMAIN - NO MODIFICATIONS TO DOORS OR FRAMES AL ALUMINUM
2: FURNISH AND INSTALL SMOKE SEALS AT PERIMETER OF DOOR FL FLUSH DOOR
3. EXIT SIGN SHALL BE INSTALLED ABOVE DOOR - TENANT SIDE (BY ELECTRICAL) FR FRAME
4.. PROVIDE LEVER TYPE HANDLES ,MOUNTED AT 34" AFF. HM HOLLOW METAL
5. HOLLOW METAL DOOR AND FRAME SHALL BE PAINTED (COLOR PER LANDLOARD NR NON -RATED
STOR STOREFRONT DOOR
WD WOOD
NOTES:
I. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH
EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND
NOTIFY ARCHITECT CF MY DISCREPANCIES.
2. WALL TYPES 514ALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS
NOTED OTHERWISE IN WALL TYPES.
3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MIN. 6" GAP AT
TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE.
4. DATA/ELECTRICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL BE
SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT.
5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE
REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION.
ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC
402.15.4, 602, 603, 4 2604)
6. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO
CONSTRUCTION ANY DESCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD
FOR CLARIFICATION.
1. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO
CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL
COMMON AREA.
HARDWARE GROUPS
GROUP I - RATED HOLLOW METAL DOOR
- LEVER TYPE HANDLES - MANUFACTURER L- SERIES ,11, LEVER
HANDLE, FINISH - SATIN CHROME.
- 3 BUTT HINGES
- OVERHEAD STOP
- SMOKE SEALS
- LCN CLOSER
- MORTISE CYLINDER
- EXIT DEVICE
SEE WALL TYPE
5/8" GWB
METAL STUD HEADER
HOLLOW METAL FRAME
AND ANCHORAGE
HEAD DETAIL
1 1 /2" = 1' -0"
SEE WALL TYPE
5/8" GWB
METAL STUD JAMB
JAMB DETAIL
HOLLOW METAL FRAME AND
ANCHORAGE
1 1/2" = 1' -0"
WALL. TYPES
N
Ma
3 5/8"
4 '1/8'
I- 1-R
WALL TYPE I (I -HR RATED) UL DESIGN • U -465
- EXISTING 5/8" TYPE X GWB
- 6" METAL STUD FRAMING
- 5/8" TYPE X GWB AT TENAT SPACE
- WALL SHALL CONTINUE UP TO STRUCTURE W/
GWB STOPPING 6" FROM STRUCTURE
; I CONTRACTOR SHALL VERIFY THE STATUS CF
-4 GWB WITHIN TENANT SPACE TO MEET MEET I -HR
RATED ASSEMBLY REQUIREMENT.
2
WALL TYPE 2 (1 -HR RATED) UL DESIGN • U -465
- EXISTING 5/8" TYPE X GWB
- DEMO 6" METAL STUD FRAMING AND
REPLACE WITH
- 3%" METAL STUD FRAMING
- 5/8" TYPE X GWB AT TENAT SPACE
- WALL SHALL CONTINUE UP TO STRUCTURE W/
GWB STOPPING 6" FROM STRUCTURE
CONTRACTOR SHALL VERIFY THE STATUS OF
GWB WITHIN TENANT SPACE TO MEET MEET I -HR
RATED ASSEMBLY REQUIREMENT.
REVIEWED FOR
CODE COMPLIANCE
APPRAVED
SEP 15 2010
City of Tukwila
BUILDINGnnhIF4InN
aTVOFTUALA
SEP 0 8 2010
PERMIT CENTER
Westfleki
Southcenter
633 Southorlter Parkway
TUkNa, WA., 9a188 -2088
200 - 248 -0423
WESTFIELD DESIGN &
CONSTRUCTION
11601 Wilshire Boulevard, 11th
Floor Los Angeles, California
90025 -1748
Telephone 310 478 4456
Facsimile 310 478 4468
THIS DRAVANG IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE
ARCHITECT AND MAY NOT BE REPRODUCED YATHCUT THE ARCHITECTS
PERMISSION AND UNLESS THE REPRCOUCIION CARRIES THE ARCHITECT'S
NAME. ALL DESIGN AND OTHER INFORMATON SHOWN ON THE DRAINING ARE
r� USE ON ME SPECIFIED PROJECT ONLY AND SHALL NOT BE USED
OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(200) 624 -2777 • FAX (206) 024 -2973
ISSUE
ISSUE
PERMIT SET
DATE:
SEPT. 3, 2010
PROJECT ARCHITECT
WEJ
PROJECT MANAGER
WEJ
FLOOR PLAN
ENLARGED
FLOOR PLAN
AND DETAILS
A1.0
SMSA #1022.13