HomeMy WebLinkAboutPermit D06-313 - Various Tenants - Building 32 - ReroofVARIOUS TENANTS
BUILDING 32
1018 -1034 INDUSTRY DR
EXPIRED 02 -14 -07
D06 -313
Parcel No.: 2523049071
Address: 1018 INDUSTRY DR TUKW
Suite No:
Tenant:
Name: VARIOUS TENANTS, BLDG 32
Address: 1018 -1034 INDUSTRY DR, TUKWILA WA
Contact Person:
Name: GLEN ANDERSON
Address' 3816 S RD, STE A, MUKILTEO WA, 98275
Phone: 425 423 -0900
Contractor:
Name: COMMERCIAL INDSTRL ROOFING INC
Address: 15331 HWY 99, LYNNWOOD, WA 98037
Phone: 425 - 745 -8148
Contractor License No: COMMEI *205JJ
Value of Construction: $90,000.00
Type of Fire Protection:
Type of Construction:
doc: IBC - PERMIT
City &IV Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
DEVELOPMENT PERMIT
Owner:
Name: CALWEST INDUSTRIAL PROP
Address: CIO DELOITTE & TOUCHE LLP, 2235 FARADAY AVE #O, CARLSBAD CA 92008
Phone:
**continued on next page**
Expiration Date: 05/16/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -313
Issue Date: 08/17/2006
Permit Expires On: 02/13/2007
DESCRIPTION OF WORK:
REROOF: TEAR OFF EXISTING 4 -PLY BUILT -UP ROOF SYSTEM DOWN TO WOOD DECK. INSPECT WOOD DECH,
MECHANICALLY ATTACH FIBERGLASS BASE SHEET, SET TWO LAYERS OF FIBERGLASS PLY SHEET IN HOT ASPHALT.
INSTALL A FIBERGLASS CAP SHEET FOR THE TOP SURFACE OF THE ROOF SYSTEM.
Fees Collected: $1,894.05
International Building Code Edition: 2003
Occupancy per IBC:
D06 -313 Printed: 08 -17 -2006
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
City (*Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206431 -3670
Fax: 206431 -3665
Web site: ci.tukwila.wa.us
N
N
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter:
I hereby certify that I have read and
Print Name:
N
Permit Number: D06 -313
Issue Date: 08/17/2006
Permit Expires On: 02/13/2007
Number: 0 Size (Inches): 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Center Authorized Signature al1$JM IAA A44q.`k Date: Og(flidie
1111 ` is per ✓ mit and know the same to be true and correct. All provisions of law and
ordinances governing this work will b&abmpltedhvith, whether specified herein or not.
The granting of th' permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating cons i tiipr the perforp E e of work. 1 am authorized to sign and obtain this development permit.
Signature: l J � J � �, Date: 7/77D
/an s. OvgA
This permit shall become null and void if the works not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
doc: IBC - PERMIT D08 -313 Printed: 08 -17 -2006
doc: Conditions
City ah'Tukwila
Parcel No.: 2523049071
Address' 1018 INDUSTRY DR TUKW
Suite No:
Tenant: VARIOUS TENANTS, BLDG 32
1: ***BUILDING DEPARTMENT CONDITIONS***
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
PERMIT CONDITIONS
**continued on next page**
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -313
Status: ISSUED
Applied Date: 08/11/2006
Issue Date: 08/17/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
006 -313 Printed: 08 -17 -2006
City bi Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
Steven M. Mullet, Mayor
Steve Lancaster, Director
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name:
doc: Conditions
,,1? ----- \ ,
1D S' 7 an
Date: 8//7/ 17
D06 -313 Printed: 08 -17 -2006
SITE LOCATION
Name:
Mailing Address:
E -Mail Address:
Contact Person:
E -Mail Address:
CITY OF TUKWILA��
Community Developmenttepartment
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.ci.tukwila.wa.us
4lda.k 3z
Company Name: ( .O✓YryNGt vr s-
Q: Applicatio,,Worms-Appacaliom On LIn.0 -2006 - Permit Application.doc
Revised: 1-1006
Building Pe rlasVQ�:
Mechanical PermitTT
Plumbing/Qas Permi
- Public Wor'1cs Perin
Project No
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
King Co Assessor's Tax No.:
Site Address: IO1Q—I °37 .ZJ ✓Sk 'r; tr 14140;10-
Tenant Name: Mgt✓a
Property Owners Name: Wtl1 szalvik.As /Yv cAsNbS LIZ
Mailing Address: `000 (%,-,j /stJn &4,9 se;,-„,
O /a/
71S/6qp /1
4 & Gtre loo -). ton
04% Q0 / r7tiT
Contact Person:
E -Mail Address:
Suite Number: Floor:
New Tenant: D .... Yes
o etre -F /1,4- 146- ettei. r
✓�%2v�,�y 111*
9$/
City State Zip
EKNo
Day Telephone: Pr-1/23 -0/oo
/ 7,447 >,4 year
City State Zip
Fax Number: 9 y73- 0,72.-
GENERAL CONTRACTOR INFORMATION - .
(Contractor Informatioj for Mechanical (pg 4) for Plumbing and Gas Piping (pg S)) . ..
Mailing Address: 3g j6 5 AID Sk 1/Y A ep t fr. - M41100 1✓4- ?G2
' 4 / City State Zip
/
Contact Person: ( {cn t'rt^ , &tf p-'
E -Mail Address: , 1e4 6 c,:.....,0 0.6,- t ea*
Contractor Registration Number: (.O t7 A ex / ,I`' 2 or T
Day Telephone:
Fax Number:
Expiration Date:
f Lc -Ito - &spa
ynj- y22 -Oflt
C /Icior
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name:
Mailing Address:
State
City
Day Telephone:
Fax Number:
Zip
ENGINEER OF RECORD - All plans niust be wet stamped by tngirteei of Record
Company Name:
Mailing Address:
State
City
Day Telephone:
Fax Number:
Zip
Page 1 of 6
Valuation of Project (contractor's bid price): $ ? 1:1 1 000 �r Existing Building Valuation: $
Scope of Work (please provide detailed information): ye dt ?,r td h, Y-, e„,„, /`� -
fy l}f P l cb✓rt 4 .joJQ d�c/L. �.wf' -swell Jet HPJ,�rn -egl) q> f G4 �i #rfl
me- yin/ fe Ls* of 141f I >z4+
0-4 /tmcf act 4 ktr 4, S.L,Lce & A NAGif en .
Will there be new rack storage? ❑ ..Yes ❑.- No (If yes, a separate permit and plan submittal will be required)
• Provide'- AIIBuildingAreas in Square Footage Below,.
I" Floor
2 Floor
3 Floor
Floors
Basement
Accessory Structures
Attached.Garage
Detached Garage
Attached earport" "
Detached Carport
Covered Deck
Uncovered Deck
Existing
Interior
Remodel
Addition CO ;
Existing
Structure -
"Type of
Construction ',
Per IBG.
cot'
aneyFper:
BC '
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq R): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0.. Sprinklers ❑_Automatic Fire Alarm ❑ ..None ❑ - Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes ❑ ..No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
SEPTIC SYSTEM:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q1ApplicmioneWomu- Applications On LineU -2006- Permit Applicaton.doe
Revised: 0-2006
bh
Page 2 of 6
PERMIT APPLICATION •O.� Applicable to all permits in this s licntion
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 lnternational Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 01 R OR AUTHORIZED AGENT:
Signature:
ey
Print Name: z- o A 4 1 / _ A— °^ Day Telephone:
Mailing Address: 3814 So -' c&O , Sru 4 / /fro
f tr
' � it 6k- 4—lef ..
Date Application Expires:
Date Application Accepted:
oth t l
Q: Applicationaonna-Appliadom On LineV- 2006 - Permit Application.doc
Revised: 4
ba
City
Date:
State
9s
Zip
Page 6 of 6
Fixture Type;
Qty
Fixture Typ
Qty
ixture Type
i ature Type:
Qty
Bathtub or combination
bath/shower
Drinking fountai . r water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, ' direct
waste
Clothes washer, domestic
Floor drain
Sinks,
Dental unit, cuspidor
Shower, single head trap
Ur'r'. s
Dishwasher, domestic,
with independent drain
Lavatory
ter Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
: ter heater and/or
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating .
equipment
V
Repay er alteration
of drain e or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific
gas
Additional medical
inlets/outlets — si . r more
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
Contact Person:
E-Mail Address:
P
Valuation of Proj contractor's bid price): $
Scope of Work (please ovide detailed information):
Indicate type of plumbing fixtures and/ores piping outlets being installed and the quan • below:
Q:tApplk stiomWrms-Appaution On Linen -3006 - Pamir Appfintion. x
Revised 42006
eh
State
. Zip
Page 5 of 6
RECEIPT NO: R06 -01246
Initials: JEM
User ID: 1165
SET TRANSACTIONS:
Set Member Amount
D06 -312
D06 -313
D06 -314
TOTAL:
ACCOUNT ITEM LIST:
Description
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
City of Tukwila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 -431 -3665
Payee: COMMERCIAL INDUSTRIAL ROOFING, INC.
1,607.61
1,894.05
1,736.51
5,238.17
SET RECEIPT
Payment Date: 08/11/2006
Total Payment: 5,238.17
SET ID: 0811 SET NAME: COMMERCIAL INDUSTRIAL ROOFING
TRANSACTION LIST:
Type Method Description Amount
Payment Check 034610 5,238.17
TOTAL: 5,238.17
Account Code Current Pmts
000/322.100 3,166.46
000/345.830 2,058.21
000/386.904 13.50
TOTAL: 5,238.17
8505 06/11 9710 TOTAL 5238.17
Project:
Ce,e /..r.,�
Type of Inspectio
/? �8ro -6.- 0r
Address: °
Date Called:
/04 . 4 7.4. SA %yyyy
Special Instructions:
Date g7g CO
//
Requester:
c- At e4 . let
.
Phone No:
yyr-, r'i- 4
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
Approved per applicable codes. Corrections required prior to approval.
OMMENTS:
Inspector:
INSPECTION RECORD
Retain a copy with permit
142Z%-. 3
( - 1.-/ga
(206)431 -36x0
El $58.b0t INSPECTION N FEE RE4UIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
August 1
City of Tukwila
Public Works Departmen
Permit Center
6300 Southcenter Boulevard
Tukwila, WA 98188
e � " '1 . 5 2006
Oty Of Tukwila 1
BUILDING DIVISION
We will remove the existing 4 -ply built-up roof system down to the substrate. We will examine
the substrate along with the full time onsite Inspector, provided by building owners. We will
replace all deteriorated or obviously deflected plywood.
Attention: Ken Nelson
Project: Tukwila Commerce Center Bldg # 32 1018-1034 Industry D
Subject: Commercial Building Roof Replacement Permit Submittals
Scope of work will be as follows:
Roofing
3816 SOU
The new roof system will consist of the one layer of G2 glass base sheet mechanically
attached to substrate with 4 rows of nails 9" on center. Two layers of type-4 fiberglass ply
sheet will follow, both set in Type III roofing asphalt. Base flashings will consist of a smooth
surfaced modified followed by a standard 72 Ib. fiberglass mineral surfaced cap sheet. A 72.
cap mineral surfaced cap sheet will be the final layer of the field roof system. AU pipe
penetrations and metal flashings will be replaced.
Attached are copies of the manufacturer (GAF Corporation materials) UL listing for Class A
roof system and basic specification.
Insulation
The entire building is insulated per Washington State Energy Code.
If you have any questions or determine that the information provided is inadequate for review
and or approval, please give me a call at your convenience. Time is of the essence for our
client
We thank you in advance for your co- operation regarding this project.
Respectfully,
a
G4-- • �f. ----
en B. Anderson
General Manager - Commercial Industrial Roofing, Inc.
Washington State Contractor's Number
CO- MM- EI'205JJ
�S COPY
Pent N� �
Ib 6 ai 2 to awl ate adle i,
Mime U mt l did Qas mot aetl0leea
es 1& if aly .. - • - OP adlleltoe.
CIO likda
DRUM
REVIEWED FOR
CODE COMPLIANCE
Tukw'
$ nninfl \ /Ftl
RECEIVED
art
AUG 1 12006
PERMIT CENTER
VJr
•
FOUR (4) PLY BUILT UP ROOFING SYSTEM
NAILABLE DECK
? Side Lap
1
Mailable Deny
Sheathing Paper
(II required)
ivy
OAFOUS
Minuet Endued
Ca Sheet
Sue Sheet OAFOLASe
(see below) FIexPIF "1
Reeling
Asphalt
Side lap
f
2/4(
12 YEAR DIAMOND PLEDGE AND SYSTEM PLEDGE
BOTTOM SHEET
SPEC# ATTACHMENT
N -B-4 -M NAILED
NAILED
NAILED
NAILED
NAILED
NAILED
15 YEAR DIAMOND PLEDGE AND SYSTEM PLEDGE
(WEST ZONE ONLY)
BOTTOM SHEET
ATTACHMENT
NAILED
NAILED
NAILED
NAILED
NAILED
SPEC#
N- B- 4 -M/P6
BASE SHEET
STRATAVENT' NAILABLE
1175 BASE SHEET
#80 ULTIMA" BASE SHEET
MODIFIED BASE SHEET
PLY 4 w/SHEATHING PAPER
FLEXPLY" 6 w/SFEI9HNG FAPER
BASE SHEET
STRATAVEM' NAILABLE
#75 BASE SHEET
#80 ULTIMA" BASE SHEET
MODIFIED BASE SHEET
FLEXPLr 6 w/SFEITI NG B4PER
Built -Up Roofing Systems 310
GENERAL
Safety: Refer to Section Section 1.06.
DO NOT BEGIN INSTALLATION
UNTIL THIS INFORMATION IS READ,
UNDERSTOOD AND IMPLEMENTED.
CORPORATION F MA
MATERIALS
Material Requirements per 100 sq. ft.:
Asphalt (per ply) 25 lbs (1.22 kg/m
Base Sheet 1 ply
Ply Sheets 2 plies
Cap Sheet 1 ply
GUARANTEE SPECIFICATIONS
INTERPLY
PLY 4
PLY 4
PLY 4
PLY 4
PLY 4
PLY 4
JNTERPLY SURFACING
PLY 4 CAP SHEET
PLY 4 CAP SHEET
PLY 4 CAP SHEET
PLY 4 CAP SHEET
PLY 4 CAP SHEET
PLY 4 CAP SHEET
GUARANTEE SPECIFICATIONS
INTERPLY INTERPLY SIJRFACINQ
FLEXPLY 6 FLEXPLY 6 CAP SHEET
FLEXPLY 6 FLEXPLY 6 CAP SHEET
FLEXPLY 6 FLEXPLY 6 CAP SHEET
FLEXPLY 6 FLEXPLY 6 CAP SHEET
FLEXPLY 6 FLEXPLY 6 CAP SHEET
r
REVIEWED FOR
CODE COMPLIANCE
jlnnnn */CIl
AUG 1 5 2006
City Of Tukwila
BUILDING DIVISION
Pe-
GAF INPERIALS
CORPORATION
e-
CORPORATION
WALL/CURB FLASHING SPEC PLATE: 2W
TWO (2) PLY BASE FLASHING COMBUSTIBLE SUBSTRATE
Wood
Wall
Fasteners
Coentedlestdng
WALL/CURB FLASHING SPEC PLATE: 3W
THREE (3) PLY BASE FLASHING COMBUSTIBLE SUBSTRATE
GAF INOMRIALS
CORPORATION
G
O O —
f6
8 C o in
LU o c - c ,
�" � _ z-
W c 6 G
o
�0 i t m
IX Rating
Specification
Numbers
Insulation
insulation
Attachment
Base Sheet/
Membrane
Base Sheet/ Membrane Detail
Slope
Class A
Option 1
I-0- 2- 20/30FR (CA)
I- 1- 2- 20/30FR (CA)
N- 1- 2- 20/30FR (CA)
r ----
Optional:
•
•
•
G
Any thickness
EnergyGuard Perlite
Roof Insulation
Polyisocyanurate
, Glass Fiber
Wood Fiber
Base Sheet
Base Sheet
1 or more layers:
• Type G2,
• GAFGLAS #75 Base
• Mod Base Plus
Ply Sheet
• Ruberoid 20 FR Base
Membrane:
1 or more plies:
• Ruberoid 30FR
Base Sheet
•
• GAFGLAS Ply 6
Membrane:
1 Layer. '
• Type G3,
• GAFGLAS Mineral Surfaced Cap sheet
v iii
Asphalt Felt System, Combustible deck...
UL Listings
Basic System Type:
Deck Type:
- c
D p
Z
m
Cold Applied
Combustible, New
Deck C -15/32 Wood Plank Boards, Plywood, Oriented strand Board, etc.
2
5
i{
IMAM"
AIDE -113
NO ESTCDAET WARM" Mg
EX 71i-iWF -71AA
RREEF MANAGEMENT
TUKWILA, WA
a
5
®
®0
TUKWILA, WA
H
TUKWILA COMMERCE CENTER MUM- RS""
AREA- XXXXX SQ. FT.
1018 -1034 INDUSTRY DRIVE - BLDG. 32
2005 ROOF REPLACEMENT
HALE- 03/02/05
MIT BY- Jv
SKYLIGHT
HVAAUNIT
VENT
SWAMP COOLS
EXHAUST FAN
ANTENNA
SAIELLTE DIE
ROOF HATCH
ROOF DRAIN
SCUPPER
01-02 -2007
GLEN ANDERSON
3816S RD, STEA
MUKILTEO WA 98275
RE: Permit No. D06-313
1018 INDUSTRY DR TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each Extension requests mast be In writinr and erovide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 02/14/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely, er dA:PICV444
Permit Technician
xc: Permit File No. D06 -313
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
•
•
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665
ACTIVITY NUMBER: D06 -313 DATE: 08 -11 -06
PROJECT NAME: VARIOUS TENANTS, BLDG 32
SITE ADDRESS: 1018 -1034 INDUSTRY DR
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Budding Nvis on
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete E Incomplete ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Approved ❑
Notation:
Documents/routing slip.doc
2 -28-02
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
REVIEWER'S INITIALS:
,,.?ERMIT COORD COPY ,"
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
Structural Review Required
Approved with Conditions
6I( 4r IC
❑ Permit Coordinator
DUE DATE: 08-1506
DATE:
DATE:
Planning Division
C
Not Applicable ❑
No further Review Required
DUE DATE: 09-12-06
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
COMMEI *205JJ
Licensee Name
COMMERCIAL INDSTRL ROOFING INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600346392
Ind. Ins. Account Id
43988900
Business Type
CORPORATION
Address 1
3816 SOUTH RD STE A
Address 2
City
MUKILTEO
County
SNOHOMISH
State
WA
Zip
98275
Phone
4254230900
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/11/1980
Expiration Date
5/16/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
DUGAN, CHRISTINA
D
PRESIDENT
04 /11/1980
DUGAN WILLIAM L
VICE
PRESIDENT
04 /11/1980
Look Up a Contractor, Electric' °n or Plumber License Detail Page 1 of
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= COMMEI *205JJ 08/17/2006