Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D10-281 - THRIFTBOOKS - TENANT IMPROVEMENT
THRWFB 0 OKS 18200 CASCADE AV EXPIRED 07 -09 -11 D10 -281 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: htV/Iwww.ci.tukwila.wa.us Parcel No.: 7888900170 Address: 18200 CASCADE AV TUKW Suite No: Project Name: THRIFTBOOKS DEVELOPMENT PERMIT Permit Number: D10 -281 Issue Date: 11/19/2010 Permit Expires On: 05/18/2011 Owner: Name: RIVERPOINT TWO LLC Address: 1100 OLIVE WAY #1005 , SEATTLE WA 98101 Contact Person: Name: PAUL ENGERT Phone: 206 - 325 -2553 Address: LANCE MUELLER & ASSOCIATES , 130 LAKESIDE AV - SUITE 250 98122 Contractor: Name: POE CONSTRUCTION Address: PO BOX 1838 , AUBURN WA 98071 -1838 Contractor License No: POECOI *247QZ Phone: 253 833 -2400 Expiration Date: 05/01/2011 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT INCLUDING NEW OFFICES, MULTI- PURPOSE ROOM AND STORAGE. THE SUSPENDED CEILING, LIGHTING AND HVAC SYSTEMS ARE CURRENTLY INSTALLED WITHIN THE SPACE. Value of Construction: $102,000.00 Fees Collected: $2,460.36 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N doc: IBC -7/10 D10 -281 Printed: 11 -19 -2010 • Permit Center Authorized Signature: Date: • I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance o • rk. I aw authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /7// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done m conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: IBC -7/10 D10 -281 Printed: 11 -19 -2010 shall not be valid. The issuance of a permit ) d on construction documents and other dat 11 not prevent the Building Official from requiring the correcti errors in the construction documents and data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs m cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) doc: IBC -7/10 D10-281 Printed: 11 -19 -2010 29: Aisles leading to required exits shall belevided from all portions of the building and tilquired width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 32: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 33: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 38: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 39: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 40: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D10 -281 Printed: 11 -19 -2010 CITY OF TUKWIL• Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht0://www.ci.tulcwila.wa.us Building Permit No. 0— 2 g_( Mechanical Permit No Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 7888900170 Site Address: 18200 Cascade Ave. South - Second Floor Suite Number: Floor: New Tenant: J Yes Tenant Name: ThriftBooks Property Owners Name: O'Keefe Development Mailing Address: 18300 Cascade Ave. South, Suite 130 p Seattle WA City State 2 ..No 98188 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Paul Engert - Lance Mueller & Associates Mailing Address: 130 Lakeside Ave Seattle WA 98122 Day Telephone: (206) 325 -2553 E -Mail Address: pengert@Imueller.com City State Fax Number: (206) 325 -2553 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Smajic Construction, LLC Mailing Address: 12219 SE 65th Street Bellevue WA 98006 Contact Person: Adi Smajic E -Mail Address: smajic @msn.com Contractor Registration Number: City State Zip Day Telephone: (206) 419 -8090 Fax Number: (425) 378 -2593 Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Same as contact above Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\Applications\ronns- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORI'ION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 102,000 Existing Building Valuation: $ 2,000,000 Scope of Work (please provide detailed information): Interior tenant improvement including new offices, multi - purpose rota and storage. The suspended ceiling, lighting and HVAC systems are currently installed within the space. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 414 Compact: 207 Handicap: 14 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If "yes ', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Ltne\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Pagc 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 26,882 0 0 0 V -B B 2 °d Floor 28,882 4,063 0 0 V -B B 3'a Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 414 Compact: 207 Handicap: 14 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If "yes ', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Ltne\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Pagc 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: HO ED A' ENT: Print Name: Paul Engert Mailing Address: pengert@Imueller.com Date: 10/20/2010 Day Telephone: (206) 325 -2553 Seattle WA 98122 Date Application Accepted: City State Zip 10 I0 Date Application Expires: l , Staff Initials: H:\Applications\Fotms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 7888900170 Address: 18200 CASCADE AV TUKW Suite No: Applicant: THRIFTBOOKS RECEIPT Permit Number: D10-281 Status: APPROVED Applied Date: 10/20/2010 Issue Date: Receipt No.: R10 -02356 Payment Amount: $1,492.90 Initials: WER Payment Date: 11/19/2010 10:04 AM User ID: 1655 Balance: $0.00 Payee: MATTHEW HARPUR DAVIDSON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1320 1,492.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,492.90 1,488.40 4.50 doc: Receiot -06 Printed: 11 -19 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT ParcelNo.: 7888900170 Permit Number: D10 -281 Address: 18200 CASCADE AV TUKW Status: PENDING Suite No: Applied Date: 10/20/2010 Applicant: THRIFTBOOKS Issue Date: Receipt No.: R10 -02131 Initials: WER User ID: 1655 Payment Amount: $967.46 Payment Date: 10/20/2010 03:32 PM Balance: $1,492.90 Payee: LANCE MUELLER & ASSOCIATES ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 28641 967.46 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 967.46 Total: $967.46 doc: Receiot -06 Printed: 10 -20 -2010 . • • • • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 12' INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: : •.,r T boo 1Cn. Type of Inspection: - 1-1_*..J 14 d14 To oda't4Py ---T P tv'vVera Al Address: t 0 Zap N r4 rkt. Date Called: • Special Instructions: Date Wanted: I— I i — i t ow : Requester: Phone No: 06, -- <S t —02-711 . El Approved per applicable codes. Corrections required•prior to approval. lD COMMENTS: ✓ d14 To oda't4Py ---T P tv'vVera Al DnR2.1P4AMC/ IC4Itt• Mee Nvhaieui -F.--; 7--- i . / . or: Date: 1■-- SPECTION FEE R UIRED. P or to next inspection, fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. NtIO INSPECTION RECORD Retain a copy with permit t 10-'12 ° INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t--2—' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 7—fr7 i'trr a3 u.S Type of Inspection: Fwtg2.<or~kicy LtGeMNla Date Called: , ,_ Address: Special Instructions: . Date Wanted: it -_r o. — l I Requester: Phone No: a2elI,'SSl -bZ7?. Approved per applicable codes. Corrections required prior to approval. 3D COMMENTS: Date: SPECTION FEE EQUIRED.• Pripr to next inspection. fee must be . at 6300Southcenter Blvd.. Suite 100. Call to schedule reinspection. .. -- -:- INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT N0; CITY OF_TUKWILA BUILDING DIVISION :a- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ,Q »fz t3 / Project: 7.45/",--1/34/.0, S Type of Inspection: d`p70Q doc4/r'c, 4/ 60.70Iitij Address: / 02. - t> ens' 404 Pf 61'.',' Date Called: Special Instructions: • .. cvZeil Date Wanted: - /—. a — /t p.m• Requester: Phone No: E— .SSS" / —C)Z7 3D. ip ZM Approved per applicable codes: •• ® Corrections required prior to approval. 5 COMMENTS: 69 delid CA,:t Sis46io- /../ddX ca/:tmay" h* ACy 4 "716 iei , i'e74yti k /wr/oira' D-e- ye/liege sylti /l' I s Ai4 - #0 . LW 6. 731,41. � tor n I SPECTION FEE EQUIIRED Prior to next inspection. fee must be a'd at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: Date: i_ 7 — 1 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project :rn Type of Inspection: Adddr ss: /� �q�} Date Called: Special Instructions: Date Wanted: amm. / , Requester: Phone No: 2t——�2 2 7 el 1ZApproved per applicable codes. ElCorrections required prior to approval.. • . COMMENTS: 4L4.zIAJ % jilt/ ettif G.24,6 7ra-1 -la set/Am/et -etikve- INSPECTION FEE RE UIRED.r to next inspection. fee must be aid at 6300 Southcenter lvd.. Ste 1.00. Call to schedule reinspection. •: ::� • Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ri stb vVi Project: Type of Inspection: Address: - /1z ®a ebt:rehtve . Date Called: Special Instructions: • Date Wanted: (a.m' Requester: Phone No: Approved per applicable codes. • = . ❑ Corrections required prior to approval. COMMENTS: lInspe 740.1 !Date: R TION FEE RE UIRED. Pro r to next inspection. fee must b p 0 Southcenter Blvd.. Suite1100. Call to .schedule reinspection: e • •^ ti , . • • Date: E) SPECTION FEE REQUJRED. Prior t next inspection. fee must be - d at 6300 Southcenter Blvd-. Suite 10 . Call to schedule reinspection. ' ••• • • liftPINSPECTION RECORD Retain a copy with permit INSP PERMIT NO. .I®4Sf CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P 'ea- Type of spection: t Address: 12O7 l �,� t-d1 ' Date al ed: Special Instructions :. • aie Wanted: '7��a_.11.. • 12.-1_1 '"1� p.m. Requester: Phon No: - �� - S 1--02- 9 Approved per applicable codes. El Corrections. required prior to approval. •.. COMMENTS: 1L —0 tifj,Kt sJ,r t.1 ©- - e3(o ! 144® .��-es oak) �ti e :�,`` .J I Inspect • . Date: next inspection,•fee•must be Cat to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS t i CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park,East, Tukwila, Wa. 98188 206 =575 -4407 Project: l inr 411 b Type of Inspec�ttion: r' /"v frto Address: IVA° CgegdQ Suite #: 240 /4 lor✓/erl" ZO3 Contact Person. Special Instructions: _ Phone No.:(c9 l u ,,., id i 04 (..:--/ ,e 706 242- aiSS-49 r>iApproved per applicable codes. Corrections required prior to approval. • COMMENTS: • 4-,4 .. Sprinklers: Hrs.: Fire Alarm: Hood & Duct: f /', �' /�.- A et..I ,. Se te-e k-„ • Pre -Fire: lA/ • V. 1 __ — • — - - - •••-• ----rtzt--- - --AL — -1-; tl.. I ptiuic.t,ca- „" e et—Q, . r,v‘j 5 • C 0-.1p%. k j m P e eI 648? n _ 6_,) . „Li iiil\v\ , • . • _1 fm-,14 • _T\)eB t 4-).A.4.2. 7:2–__ . Needs Shift Inspection: 4-,4 .. Sprinklers: Hrs.: Fire Alarm: Hood & Duct: Monitor: • Pre -Fire: Permits: , Occupancy Type: • Inspector: i� ,_,O,,,, ! c 4-,4 .. Date:1 . ! l J,, Hrs.: r c n $80.00 REINS ECTION FEE REQUIRED. Your will receive an invoice from the City of Tukwila Fina ce Department: Call to schedule •a. reinspection. Word /Inspection Record Form.Doc 1/13/06 T:F:D: Form FR 113 • • • _• INSPECTION NUMBER /D- ,5. -2?-9 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: TAv, c.i book S .F Type of Inspection: Vy,vi t.l4Y (oJG r Address: ISz oe Suite #: ; r 0'`0At Ade $ • Contact Person: Co Lurfrigo4 f / eE ►cif. TDc f.G c 4 Special Instructions: Monitor: . Phone No.: z o6 - Z 3-- 8S- o° o d i c zt. _6',I- ?a`gre..c Approved per applicable codes. XCorrections required prior to approval. COMMENTS: r' ode e q..3 - 3 ccvi1; ko s l I ew .S t Needs Shift Inspection: .F Sprinklers: Date:. I 118 i ! • :. Fire Alarm: .Hrs.: /.Q Hood & Duct: ' Monitor: Pre -Fire: Permits: \. Occupancy Type: I• Inspector: ) .F y .• Date:. I 118 i ! • :. • .Hrs.: /.Q • $80.00 REIN'ECTION FEE REQUIRED. You will receive an invoice from the,City of Tukwila' Finance Depait`m'e'n '. {Call tescheduile a reinspection. Word /Inspection Record Form.Doc ;,. • 1/13/06 .� ., .. T.F.D. Form F.P. 113 • , .� 1 • • - INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /o- F-?,? PERMIT NUMBERS CITY.OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: /� �7 t v ;*/ Geet .S . e .y� Type of Inspection: FA. lr,P/AF- Address: /12.00 CageaJ AJe S. Suite #: 703 Contact Person :I,.,,4 4) c!,...44,6 k'.ii.c /sdr? Special Instructions: Phone No.: ,2 06,. 9� ._. z j iv Pc1Approved per applicable codes. COMENTS: I I Corrections required prior to approval. "iv t AID Nn rivt6k,e k reiv 5 c4Pe wGr -. b.r, (`ay. e...• — fat_ k4/ s' fkr4seo 4yLje dk_ a Needs Shift Inspection: - Sprinklers: Fire Alarm: Hood & Du ct:_ Monitor: Pre -Fire: Permits: 1 Occupancy Type: f Inspector: y .. es+ "'1 .. . • Date: .. / 4 /a( t Hrs.: /. U 1 n $80.00 REINS ECTION FEE REQUIRED. ou will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 2006 Washington State Nonresidential Energy Code Compliance Form anterior' ng UM m LT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address ThriftBooks Date 10/20/2010 18200 Cascade Ave South For Building Department Use FILE COPY e� t No. Tukwila, Washington Applicant Name: Lance Mueller S Associates Applicant Address: 130 Lakeside Ave, Seattle, Washington Parm Applicant Phone: 206 325 -2553 Project Description ❑ Plans Induded requirements. ❑ New Building ❑ Addition -' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance O Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ISI Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2'- Area in ft2 Allowed x Area ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, REVIEt tta a �€ eu ent limiting devices or of the transformer. lI. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. CODECOMPLIANCE AP®PAV!D NUV 03 2010 1tO- City of Tukwila BUILDING DIVISION ECEIVED OCT 20 2010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form ;Inter..io;i ac 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Q ualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants /bars' 1.3 Post office 1.1 Dormitory 1.0 Retain°, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia9, assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses", storage areas 0.5 Hotel banquet/conference /exhibition ha113•4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building Iobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specificall di ec ed otherwise by subsequent footnotes. 1VED 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. !I 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. OCT 2 0 2010 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. �T (ENTER 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w may b used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 06 -01 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director PAUL ENGERT LANCE MUELLER & ASSOCIATES 130 LAKESIDE AV - SUITE 250 98122 RE: Permit No. D10 -281 18200 CASCADE AV TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/10/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 07/10/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D10 -281 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Pii COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -281 DATE: 10 -20 -10 PROJECT NAME: THRIFTBOOKS SITE ADDRESS: 18200 CASCADE AV Su X Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # Revision # After Permit Issued EPARTMENTS: (-P`CO uilding D o(�''� - n ublic W r ` to "F re Prevve tion L' L Structural n ��/T PIla ningNDivision Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 0-21 -10 Complete Comments: Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -1 8-10 Approved ❑ Approved with Conditions X Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name POE CONSTRUCTION INC UBI No. 171004362 Phone 2538332400 Status Active Address Po Box 1838 License No. POECOI.247QZ Suite /Apt. License Type Construction Contractor City Auburn Effective Date 11/9/1976 State WA Expiration Date 5/1/2011 Zip 980711838 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NORTHC1905CQNORTHWAY CONSTRUCTION INC Construction Contractor General Unused 2/18/2010 2/18/2012 Active Business Owner Information Name Role Effective Date Expiration Date POE, CHARLES E President 03/01/1996 Amount PETERSON, ALAN D Secretary 04/25/2000 DTC0526D9242C0F10 WILLIAMS, WAYNE W Vice President 03/01/1996 FRY, KYLE R Treasurer 03/12/2003 02/18/2010 CLARK, DENNIS M Chief Operating Officer 07/09/2003 01/16/2006 REIFSCHNEIDER, CAROL M Secretary 01/01/1980 07/09/2003 WELFRINGER, SUZANNE M Treasurer 11/09/1976 07/09/2003 POE, FRED W 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 SAFECO INS CO OF AMERICA 5698019 05/01/2002 Until Cancelled $12,000.00 03/05/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 30 CHARTER OAK FIRE INS CO DTC0526D9242C0F10 05/01/2010 Until Cancelled $1,000,000.0004 /29/2010 29 CHARTER OAK FIRE INS CO DTC0526D9242C0F09 05/01/2009 05/01/2010 $1,000,000.00 04/20/2009 28 CHARTER OAK FIRE INS DTC0526D92421N0 05/01/2007 05/01/2009 $1,000,000.00 04/21/2008 27 TRAVELERS INDEM OF CT DTC0526D92421ND 05/01/2007 05/01/2008 $1,000,000.00 04/20/2007 26 TRAVELERS INDEMNITY CO OF AMER DTC0526D92421ND 05/01/2005 05/01/2007 $1,000,000.00 04/19/2006 25 TRAVELERS INDEMNITY CO KC08400088 05/01/2005 05/01/2006 $1,000,000.00 04/07/2005 https://fortress.wa.gov/lni/bbip/Print.aspx 11/19/2010 CASCADE AVENUE SOUTH : 'jl I •�• E 17,37' 1 Ic W I'28'50" E 1345.35' - a canr woo Em7re ur.i,0110 r+A BUILDING 1 18300 CASCADE AVE. SOUTH =AVE MILL *tam o68S �Irlclrlcl` T BUILDING 2 18200 C �y1 ►' `' • o A Hjiiv .0 T c clrcIcf c 1, t \�;R��`�, °�' Icic •� cic a c�c�c�c;cicicic c c'alr�e'.rlejrc�c'c�e�c cic�clelc�ejelc�clsjclelc�el« r� � °= °e {� Ii '.'.�j_.__-- __..1.___�_ _j `1 °'`i WEST VALLEY HIGHWAY • '' �- ABBREVIATIONS 1 Q SITE PLAN /7 NO SCALE Z w ADJ ALT AFF ALUM L ANOD. ACT BLDG. BLK'G. BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FE FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN . DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FIRE EXTINGUISHER FACTORY FINISH FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FT FTIC FURN GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FOOT /FEET FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MF77ANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERMO TYP VAR VCT VEN VERT VWC W/ W/O WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL VARIES VINYL COMPOSITION TILE VENEER VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD RE'1/tSIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. AREA OF WORK THIS PERMIT SECOND FLOOR SEPARATE PERMIT REQUIRED FOR: fat Piping City of Tukwila BUILDING DIVISION GENERAL NOTES QQ VICINITY PLAN NO SCALE FILE COPY Permit No Plan review approval is Approval of construction docume t'r1; isolation of any adopted e approved Field Co ' By Date: . ////9//0 City Of �iukwila BUILDING DIVISION 1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. D OTHERWISE. 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECTS APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS `SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 16. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. 19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4" IN 10 " -0 ". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. tenant improvement ThriftBooks 18200 Cascade Avenue South Tukwila,WA PROJECT. NOTES TAX LOT NUMBER: 7888900170 LEGAL DESCRIPTION: SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S 78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N 11d 23' 50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11° 23' 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A OF 62D 57' 52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF & PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44° 29' 00" E 96.32 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET S 82° 08' 00 "E 100.00 FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M/U TO W/ MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33' 20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51° 37' 10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.14 FEET ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEET THEN N 78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE II OF CORPORATE PROPERTY INVESTORS BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA BOUNDARY LINE. ZONE: SITE AREA: CONSTRUCTION TYPE: BUILDING AREA: NORTH BUILDING NO. STORIES. SOUTH BUILDING NO. STORIES PARKING REQUIRED: PARKING PROVIDED: CODES USED: TENANT AREA: OCCUPANCY: OCCUPANT LOAD: TENANT: SCOPE OF WORK: C /CU 6.58 ACRES V -B FIRE SPRINKLERED 53,625 2 53,625 2 278 STALLS 414 STALLS 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL FIRE CODE ASHINGTON STATE ENERGY CODE 2009 WASHINGTON STATE BUILDING CODE 2009 PLUMBING CODE 2006 MECHANICAL CODE 2003 ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES 4,063 USEABLE SQ. FT. (SECOND FLOOR) B - OFFICE 100 SQ. FT. /OCCP. 4,063/100 = 41 OCCUPANTS THRIFTBOOKS INTERIOR TENANT IMPROVEMENT ON THE SECOND FLOOR OF APPROXIMATELY 4,063 SQ. FT. THE WORK CONSISTS OF BUILDING NEW OFFICES, OPEN OFFICES, BREAKROOM, CONFERENCE ROOM AND IT ROOMS. THE SPACE CURRENTLY HAS A COMPETE SUSPENDED ACOUSTICAL TILE CEILING AND LIGHTING SYSTEM. A PORTION OF EXISTING LIGHT FIXTURES WILL BE RELOCATED. THE SPACE WILL BE ACCESSED BY MEANS OF AN EXISTING CORRIDOR. BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: O'KEEFE DEVELOPMENT COMPANY 1100 OLIVE WAY, SUITE 400 SEATTLE, WA 98101 T. (206) 236 -6200 F. (206) 236 -6160 CONTACT: HARPUR DAVIDSON EMAIL: harpur @okeefedevelopment.com LANCE MUELLER & ASSOCIATES 130 LAKESIDE AVE SEATTLE, WA 98122 T. (206) 325 -2553 F. (206) 328 -0554 CONTACT: PAUL ENGERT EMAIL: pengert@Imueller.com SMAJIC CONSTRUCTION, LLC 12219 SE 65th STREET BELLEVUE, WA 98006 T. (206) 419 -8090 F. (425) 378 -2593 CONTACT: ADI SMAJIC EMAIL: smajic @msn.com DEFERRED SUBMITTALS 1. PLUMBING WORK UNDER SEPARATE PERMIT 2. MECHANICAL WORK UNDER SEPARATE PERMIT 3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT INDEX OF DRAWINGS TA1.1 COVER SHEET / SITE PLAN TA2.1 1/16" OVERALL BUILDING PLANS TA2.2 1/8" SECOND DEMO. / FLOOR PLANS TA2.3 1/8" SECOND CEILING PLAN TA3.1 WALL SECTIONS / CEILING DETAILS TA3.2 DOOR SCHEDULE / INTERIOR ELEVATIONS/DETAILS L 092011 REVIEWED FOR-- COAPPPnvFf DECOMPLIANCE NUV 0 3 2010 . Clty of Tukwila BUILDING DIVIRInni RECEIVED OCT 2 0 2010 PERMIT CENTER NO291 AREA OF WORK THIS PERMIT EGRESS PLAN ■ 2r-0' ® ®O CD 22 -0• 22'-0• 17 22' -0• MIN. EXIT SEPARATION 121' / 3 = 40' 47' PROVIDED OCCUPANT LOAD 4,063 SQ. FT. / 100 = 41 OCCUPANTS 22'-0' EXIT DISTANCES PLAN 22'-0• EGRESS PATHWAY UFLOOR -2 OVERALL PLAN 1/16" =1' -0" EGRESS PATHWAY IIIIIiil 22' -10• EXIT • • W • 1 FLOOR -1 OVERALL PLAN V 1/16" =1' -0" RED AIL Q 9 2011 b1o2J1 REVIEWE FOR CODE COMPLIANCE APDQf1VED NUV 0 3 2010 City of Tukwila BUILDING rIVI4Ifni RECEIVED OCT 20 2010 PERMIT CENTER 1 .a?s a U CD c o > °) 0- � O 0 a c Cc a . ocy °o co 0 CO O O f0 PERMIT SUBMITTAL C O .y > N O C 10 -114 job no. P. ENGERT drawn _ P. ENGERT checked O O N O T as 1 .a?s a U CD c o > °) 0- � O 0 a c Cc a . ocy °o 1 D 0. MAIN LOBBY BELOW UPPER LOBBY 5' -0" 6' -11%" 4' -1" 14'-4" x JAN. WOMEN MEN ®®0 0 CUST. SERVICE T - J- -rj — T J T -L -J (226) m N CV I b Al ) M '/ BREAK \(225) / r- I 30 L__ +4.2 "1@1 +42 ^ ^4g +4,2"01 it 51 III -L-. -L J -07 )1 CUST. SERVICE (227) \ /I / / / r / / r CE Al N OFC. (220) Zq PRINTER n STAIR EXIST. 12' -O" vD n rn N OFC. ACCTG. OFC. (216) CORRIDOR 3' -71/4" 111-03/4" 9' -11%" 1' -3" 205 rn N 03 N Al 8" TYP. m o N OFC. (215) vo OFC. (210 zd- O 0 N N 0 N O N \ N IT OFC. 209 12' -0" 12' -0" 16' -0" 16' -0" ARCHITECTURAL SYMBOLS & LEGEND EXISTING WALL TO REMAIN NEW WALL PER PLAN NEW WALL W/ SOUND INSULATION PER PLAN DOOR NUMBER EX. = EXIST DOOR TO REMAIN ELEVATION LETTER ELEVATION NUMBER OFC. 105 FEC FE 0 INTERIOR ELEVATION SYMBOL SHEET NUMBER ROOM NAME & NUMBER WALL TYPE REFERENCE DETAIL NUMBER DETAIL REFERENCE SHEET NUMBER DETAIL NUMBER SECTION REFERENCE SHEET NUMBER SEMI - RECESSED FIRE EXTINGUISHER CABINET SURFACE MOUNTED FIRE EXTINGUISHER GENERAL NOTES HALL (208 8" TYP -N N N N Al EXEC. OFC. 207 STAIR DN EXEC. OFC. (206) 20' -0" 1. DIMENSIONS ARE SHOWN AT FINISH FACE OF GWB UNLESS NOTED OTHERWISE. 2. FURNITURE SHOWN IN A DASHED LINETYPE IS A PLANNING SUGGESTION ONLY AND IS THE RESPONSIBILITY OF THE TENANT. 3. SEE SHEET TA3.2 FOR WALL TYPES. 4. SEE SHEET TA3.2 FOR DOOR TYPES & HARDWARE. 5. DOOR OPENINGS (HINGE SIDE) TO BE LOCATED 4" FROM ADJACENT WALLS UNLESS NOTED OTHERWISE. 6. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN THE OFFICE AND WAREHOUSE IN ACCORDANCE WITH 2009 IBC SECTION 906 AND TABLE 096.3(1). OFFICE SHALL BE LOW HAZARD. 7. GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS AND NOTIFYING ARCHITECT OF POTENTIAL CONFLICTS PRIOR TO START OF WORK. 12'-4" i\ FLOOR -1 FLOOR PLAN 1/8" =1' -0" FLOOR PLAN KEYNOTES 1. REMOVE PORTION OF EXISTING WALL AS REQUIRED FOR NEW DOOR OPENING. 2. REMOVED EXISTING DOOR AND FRAME AND INFILL WALL WITH FLUSH CONSTRUCTION. JUL 092011 1)10 ?-..81 REVIEWED FOR CODE COMPLIANCE APDI f1VED NUV 0 3 2010 City of Tukwila BUILDING DIVIslON RECEIVED OCT 2 0 2010 PERMIT CENTER m - 0 z L N 0 U ( �' c:aQ> E O CO CL N •� O O C0i c co E� c co---. 4-ai mom -o U cv N c i= > N 06/03/08 • a; co v PERMIT SUBMITTAL _ 0 0 c 10 -114 job no. P. ENGERT drawn _P.ENGERT checked 10/20/10 date m - 0 z L N 0 U ( �' c:aQ> E O CO CL N •� O O C0i c co E� c co---. 4-ai mom -o U cv N c i= > N --N N N N El D r r , 1\ I \ \I LJ Li\ r , N 1 \ L r , 1 I \I LJ I\ L 1\ I \ \I LJ 1 0 r, 1\\ \ LJ 1\ 1 i \ \1 LJ L 41411 I I \ I I \I LJ E[ J L 11 I: `I .1.: :I '. k:> I I : • L CEILING / LIGHTING SYMBOLS 0 EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE CEILING AND GRID SYSTEM EXISTING GWB CEILING NEW GWB CEILING EXISTING 2' x4' BLDG. STD FLUORSCENT LIGHT FIXTURE. EXISTING RECESSED COMPACT FLUORESCENT HALLWAY LIGHT FIXTURE EXISTING LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) EXISTING 2' x4' BLDG. STD FLUORESCENT LIGHT FIXTURE TO BE REMOVED OR RELOCATED NEW OR RELOCATED 2' x 4' BLDG. STD FLUORSCENT LIGHT FIXTURE NEW LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) NEW DIRECTIONAL LIGHTED EXIT SIGN (CM = CEILING MOUNT WM = WALL MOUNT) EMERGENCY EGRESS PATHWAY LIGHT FIXTURE (MIN. LIGHTING LEVEL IS 1 FOOTCANDLE AT + 3' -0" FROM FINISH FLOOR MAINTAINED) GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL INSTALL EMERGENCY EGRESS LIGHTING WITHIN TENANT SPACE TO PROVIDE A MINIMUM OF 1 FOOTCANDLE AT THE WALKING SURFACE. THIS IS IN ACCORDANCE WITH IBC SECTION 1006. ELECTRICAL CONTRACTOR SHALL MEASURE LIGHTING LEVELS ALONG THE COMMON PATH OF EGRESS TO MAINTAIN THE 1 FOOTCANDLE MINIMUM LEVEL TO THE EXIT DISCHARGE. THE EMERGENCY LIGHTING SHALL BE INSTALLED ALONG THE "COMMON PATH OF TRAVEL" SEE SHEET TA2.1 FOR LOCATION 2. SUSPENDED CEILING SYSTEM IS EXISTING THROUGHOUT THE SPACE. SEE SHEET TA3.1 FOR NOTES REGARDING ANY CHANGES OR ALTERATIONS TO SYSTEM. iN FLOOR -2 CEILING PLAN �O1/8" =1' -0" CEILING PLAN KEYNOTES 1. EXTEND EXISTING GWB CORRIDOR CEILING SYSTEM INTO NEW RECESSED ENTRY. 2. EXISTING GWB CORRIDOR CEILING 4UL 0 9 2011 b(o-;1B1 REVIEWED FOR CODE COMPLIANCE APDlefvFD NOV 032010 City of Tukwila ( BUILDING DIVIRION RECEIVED OCT 2 0 2010 PERMIT CENTER 0 0 c eL m E cu OEM HImo 00 O M O CO O Q) CO PERMIT SUBMITTAL C 0 d O C .ou qof 1711-01 P. ENGERT drawn P. ENGERT checked O N O a -- 'O 0 0 0 c eL m E cu OEM HImo IF HANGER WIRE IS OUT OF PLUMB GREATER THAN 1:6 COUNTER SPLAY PER ASTM C636 WALL WHICH PENETRATES CEILING GRID WALL EDGE MOLDING MAX. 8" ❖: ❖. ❖: ❖: ❖: ❖717: : ❖: ❖: ❖: ❖: ❖7:•14V MIN. 2" MIN. 3/4" @ UN- ATTACHED WALLS EDGE BRACING CEILING SEISMIC BRACING #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE @ EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID #12 HANGER WIRE ANCHORED TO STRUCTURE ABOVE SEISMIC JOINT CLIP EXPANSION SLEEVE CEILING EXPANSION JOINT WALL EDGE MOLDING CROSS TEE PER ASTM C635 STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY EDGE BRACING ISOMETRIC STEEL STUD COMPRESSION POST ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION #12 HANGER WIRE TYP. °a a a °a ° a° TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" TOP TO BOTTOM) a a o 0 a 0 CROSS TEE PER ASTM C635 MAIN CEILING BEAM PER ASTM C635 CEILING GRID SEISMIC BRACING NO SCALE SUSPENDED CEILING ARE TO COMPLY WITH THE FOLLOWING CODES AND REGULATIONS: A. 2006 INTERNATIONAL BUILDING CODE (IBC) SECTION 803.9 B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C635 AND ASTM C636 (REFERENCED IN IN 803.9). C. ASCE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 7 SECTION 9.6.2.6 D. CISCA (CEILING & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) RECOMMENDATIONS FOR SEISMIC ZONES 3-4 REFERENCED IN ASCE - 7 SECTION 9.6.2.6.2.2 E. IBC 102.1 STATES "WHERE IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, = METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE ". F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: • ONLY A HEAVY DUTY T -BAR GRID SYSTEM SHALL BE USED. ASTM - 7 SECTION 9.6.2.6.2.ITEM A. • WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE ) SHALL BE NOT LESS THAN 2 INCHES. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM B. • ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A34" INCH CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASTM -7 SECTION • STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND OR CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR ALL EDGES . CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • VERTICAL HANGERS SHALL BE NO. 12 GAGE WIRE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE WIRE SPACED AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED WITHIN 1:6 OUT -OF -PLUMB UNLESS COUNTER - SLOPING WIRES ARE PROVIDED. • LATERAL BRACING IS REQUIRED. SPLAY WIRES PODS AT 12" MAX. O.C. AND 6' -0" MAX. FROM WALLS. INSTALL TRULY COMPRESSIBLE (E.G. SPRING LOADED) STRUTS OR NO STRUTS AT ALL. RIGID STRUTS ARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 3. • CEILINGS OVER 2500 SQ . FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT WALLS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQ. FT. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM D. • FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OF ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF A LEAST 1 INCH IN ALL DIRECTIONS; OR SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM E. • CHANGES IN CEILING PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING. ASTM - 7 SECTION • 9.6.2.6.2.2 ITEM F. • CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUSPENDED INDEPENDENTLY FROM THE CEILING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM G. ilULQ9ZQ1I ATTACH 2 X" x 20 GA. METAL STUDS BRACES TO TOP TRACK W/ (2) - METAL FRAMING SCREWS REVIEWED FOR CODECOMPLIANCE App fVED NIA 0 3 2010 City of Tukwila BUILDING DIVISION 2X" x 20 GA. METAL STUDS BRACES @ 8' -0" O.C. (ALTERNATE DIRECTIONS) AT ALL WALL LOCATIONS OVER 12' -0" LONG. ATTACHED TO WOOD FLOOR STRUCTURE ABOVE bO-281 TYP. OFFICE PARTITION 112" = 1' -0" ATTACHMENT OF CEILING GRID COUSTICAL TILE ND INSULATION PER LAN A. METAL STUDS @ JITH /" TYPE "X" GWB E OWDER ACTUATED RS @ 24" O.C. TYP. R BASE NCRETE SLAB ON RECEIVED OCT 20 2010 PERMIT CENTER 1 .• .4 •' .i :• . MAKE N( WALL TC SYSTEM EXIST. A !1 :; .. .. . .; 4 .4 • CEILING 2 X" SOL FLOOR F 2% "x251 ., ., :1 ., .. V • ' 24" O.C.' EACH SII X" DIA. P FASTENE 4" RUBBI EXIST. C 7— GRADE bO-281 TYP. OFFICE PARTITION 112" = 1' -0" ATTACHMENT OF CEILING GRID COUSTICAL TILE ND INSULATION PER LAN A. METAL STUDS @ JITH /" TYPE "X" GWB E OWDER ACTUATED RS @ 24" O.C. TYP. R BASE NCRETE SLAB ON RECEIVED OCT 20 2010 PERMIT CENTER (AC o O e eL Cal E N a= N 0) 0 m O z L c -tom a? � 0 o a' 0 0 .0 U o al C . Q j N ▪ CO (206) 325-2553 06/03/08 • 1) CO v 0 PERMIT SUBMITTAL 0 0 a o c 10 -114 job no. P. ENGERT drawn P. ENGERT checked co 0 N N o ca 0 (AC o O e eL Cal E N a= N 0) 0 m O z L c -tom a? � 0 o a' 0 0 .0 U o al C . Q j N ▪ CO (206) 325-2553 11 13 5/8" 0 PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. GOOSE NECK FAUCET S.S. SINK OPEN CABINET FOR HC ACCESS in INSTALL TEMPERATURE SHIELDING ON ALL EXPOSED PIPES CV 0 CV NORTH BREAK #225 1/4". 11-0" PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. PLASTIC LAMINATE BACKSPLASH & COUNTERTOP CASEWORK SECTION 12 CASEWORK SECTION 1 =1 -0 1 11-0" 16 WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT .050 ALUM. BREAK SHAPE TO MATCH EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ FALSE MULLION 3" =1' -0" 17 DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE BASE PER SCHEDULE WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ VERT. MULLION 3" =1' -0" 13 CASEWORK KEYNOTES NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE CABINETS NOTE 2. -12" DEEP UPPER PLASTIC LAMINATE CABINETS NOTE 3. - PLASTIC LAMINATE COUNTERTOP AND 4" HIGH BACK SPLASH NOTE 4. MICROWAVE SHELF NOTE 5. - REFRIGERATOR ALL APPLIANCES TO BE FURNISHED AND INSTALLED BY TENANT 2' -1" MICROWAVE BY TENANT PLASTIC LAMINATE MICROWAVE SHELF PLASTIC LAMINATE BACKSPLASH & COUNTERTOP kr —� DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE CASEWORK SECTION (BASE PER SCHEDULE 1" =1' -0" WALL CONSTRUCTION PER FLOOR PLAN SEMI - RECESSED FIRE CABINET 3" =1' -0" SEMI - RECESSED FIRE EXTINGUISHER CABINET DOOR SCHEDULE DOOR NO. T P E DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS MAT. FIN. YY FIN. PERMIT SUBMITTAL c 0 a) 201 A 3' -0" X 8-0" WOOD BLDG. STD. H.M. CV 0 CV NORTH BREAK #225 1/4". 11-0" PLASTIC LAMINATE UPPER CABINET W/ 2 ADJUSTABLE SHELVES. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE 4" WIRE PULL TYP. PLASTIC LAMINATE BACKSPLASH & COUNTERTOP CASEWORK SECTION 12 CASEWORK SECTION 1 =1 -0 1 11-0" 16 WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT .050 ALUM. BREAK SHAPE TO MATCH EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ FALSE MULLION 3" =1' -0" 17 DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE BASE PER SCHEDULE WALL CONSTRUCTION PER FLOOR PLAN 1" DBL. FACED GLAZING TAPE .050 ALUM. BREAK SHAPE TO MATCH EXISTING STOREFRONT MAKE NO PHYSICAL CONNECTION TO STOREFRONT EXISTING VERT. MULLION EXISTING STOREFRONT SYSTEM WALL @ VERT. MULLION 3" =1' -0" 13 CASEWORK KEYNOTES NOTE 1. - 24" DEEP BASE PLASTIC LAMINATE CABINETS NOTE 2. -12" DEEP UPPER PLASTIC LAMINATE CABINETS NOTE 3. - PLASTIC LAMINATE COUNTERTOP AND 4" HIGH BACK SPLASH NOTE 4. MICROWAVE SHELF NOTE 5. - REFRIGERATOR ALL APPLIANCES TO BE FURNISHED AND INSTALLED BY TENANT 2' -1" MICROWAVE BY TENANT PLASTIC LAMINATE MICROWAVE SHELF PLASTIC LAMINATE BACKSPLASH & COUNTERTOP kr —� DRAWER W/ WIRE PULL PLASTIC LAMINATE BASE CABINET W/ ADJUSTABLE SHELVE. ALL INTERIOR SURFACES TO BE FINISHED W/ WHITE MELAMINE CASEWORK SECTION (BASE PER SCHEDULE 1" =1' -0" WALL CONSTRUCTION PER FLOOR PLAN SEMI - RECESSED FIRE CABINET 3" =1' -0" SEMI - RECESSED FIRE EXTINGUISHER CABINET DOOR SCHEDULE DOOR NO. T P E DESCRIPTION DOOR FRAME HARDWARE GROUP RATING REMARKS MAT. FIN. MAT. FIN. PERMIT SUBMITTAL c 0 a) 201 A 3' -0" X 8-0" WOOD BLDG. STD. H.M. PAINT 1 — 18" GLASS SIDELITE 202 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 — 203 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 — 204 B 3' -0" X 7'-0" WOOD BLDG. STD. WOOD BLDG. STD. 2 — 205A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 205B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 205C C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — - 206 B 3' -0" X 7' -0" WOOD BLDG. STD. WOOD BLDG. STD. 2 — 207A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 207B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 207C C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — 209A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 209B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 209C C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 210A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 210B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — 215A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 215B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 216A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 216B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 218A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 218B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 219A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 219B C 3' -0" X 4' -0" RELITE WOOD BLDG. STD. — — 220A B 3' -Cr X 7-0" WOOD BLDG. STD. 2 — 220B C 3' -0" X 4'-0" RELITE WOOD BLDG. STD. — — 225A B 3' -0" X 7' -0" WOOD BLDG. STD. 2 — 225B D 3'-0" X 8-0" WOOD BLDG. STD. H.M. PAINT 1 — DOOR / RELITE TYPES 3' -0" 1 -6 SOLID CORE WOOD DOOR (MATCH EXISTING SPECIES AND FINISH) MATCH EXISTING BLDG. STD. HOLLOW METAL FRAME 1/4" TEMPERED - GLASS 3' -0" 0 ti WOOD SUITE ENTRY DOOR & HOLLOW METAL FRAME W/ SIDELITE '/ SOLID CORE WOOD — DOOR (MATCH EXISTING SPECIES AND FINISH) MATCH EXISTING BLDG. STD. HOLLOW METAL FRAME /. %14 WOOD DOOR & FRAME (MATCH EXISTING SPECIES AND FINISH) t 2' -S" 0 WOOD DOOR & FRAME (MATCH EXISTING SPECIES AND FINISH) Ye TEMPERED GLASS WOOD DOOR & WOOD FRAME WOOD FRAME RELITE FOR -t�E COMPLIANCE APPRIlVFD NOV 0 3 2U1l1 City of Tukwila UILDING DIVISION Kr-I\ CORRIDOR DOOR & / HOLLOW METAL FRAME HARDWARE GROUPS l:* ':Pllttiy -JUL Q 9 2011 1. LEVER LOCK SET (SUITE ENTRY FUNCTION) HINGES SILENCERS CLOSER WALL STOP 2. LEVER LATCHSET HINGES WALL STOP RECEIVED OCT 20 MO PERMIT CENTER CIA N 2 ii Cal E �r film co am immi L N 0 U c° a C Q� 4 s Uco cn cn cti C O LL I— (206) 325-2553 06/03/08 • co PERMIT SUBMITTAL c 0 a) 0 c .-- Q as 0 .0 P. ENGERT drawn P. ENGERT checked 0 v- Q N y 0 -0 CIA N 2 ii Cal E �r film co am immi L N 0 U c° a C Q� 4 s Uco cn cn cti C O LL I— (206) 325-2553