Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D10-287 - 17250 SOUTHCENTER PARKWAY - VACANT SPACE - IMPROVEMENT
VACANT SPACE 17250 SOUTHCENTER PY SUITE 148 D10 -287 City otku kwila O Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us DEVELOPMENT PERMIT Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Project Name: VACANT SPACE Permit Number: D10 -287 Issue Date: 11/12/2010 Permit Expires On: 05/11/2011 Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: ANJALI WIG Address: 4811 134 PL S , BELLEVUE WA 98006 Contractor: Name: ALLIANCE REMODEL & CONST LLC Address: 5621 228 ST E , SPANAWAY WA 98387 Contractor License No: ALLIARC917RT Phone: 425 - 644 -6126 Phone: 253 686 -6277 Expiration Date: 12/30/2011 DESCRIPTION OF WORK: REMOVE EXISTING FIXTURES AND INTERIOR TENANT WALLS, AS WELL AS EXISTING DEMISING WALL TO CREATE NEW SPACE. Value of Construction: $10,000.00 Fees Collected: $464.52 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -10/06 D10-287 Printed: 11 -12 -2010 City ATukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10-287 Issue Date: 11/12/2010 Permit Expires On: 05/11/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Print Name: A. Date: 11 ,j &f i O 961)2- M, f b jV1,5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10-287 Printed: 11 -12 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Tenant: VACANT SPACE PERMIT CONDITIONS Permit Number: D10-287 Status: ISSUED Applied Date: 10/27/2010 Issue Date: 11/12/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 15: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) doc: Cond -10 46 D10 -287 Printed: 11 -12 -2010 • 0 City of Tukwila ti Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: hup://www.ci.tukwila.wa.us 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 17: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -287 Printed: 11 -12 -2010 • o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Q►u- M, bbins Date: I t 11-2- ordinances governing or local laws regulating doc: Cond -10/06 D10 -287 Printed: 11 -12 -2010 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION - &kid- -003 -�j Site Address: Tenant Name: Var akt pGt t.-e Property Owners Name: Wig Properties, LLC — S5 Mailing Address: 4811 134th Place SE 17250 Southcenter Parkway King Co Assessor's Tax No.: 2623049080/262304908116 Suite Number: 148 Floor: 1st New Tenant: ❑ Yes m ..No Bellevue City v4 State 98006 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Anjali Wig Mailing Address: 4811 134th Place SE E -Mail Address: anjaliwig @wigproperties.com Day Telephone: Bellevue City (425) 644-6126 WA- 98006 State Fax Number: (425) 865 -8648 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: TBD Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City State Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Freiheit & Ho Architects, Inc., P.S. Mailing Address: 10230 NE Points Dr., Suite 300 Contact Person: Tom Spader Kirkland E -Mail Address: tspader @fhoarch.com WA- City State Day Telephone: (425) 827 -2100 Fax Number: (425) 828 -6899 98033 Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H.\Applications \Forms - Applications On Line\2010 Applications\ 7-2010 - Permit Application doc Revised: 7 -2010 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 • 0 BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 O� OW L2 -1) Existing Building Valuation: $ Scope of Work (please provide detailed information): Remove existing fixtures and interior tenant walls, as well as existing demising wall to create new space. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 877 Compact: 27 Handicap: 21 Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:.Applications \Forms - Applications On Line \2010 Applications \7 -2010- Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la` Floor 2,067 2,067 0 0 V -B M 2"d Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 877 Compact: 27 Handicap: 21 Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:.Applications \Forms - Applications On Line \2010 Applications \7 -2010- Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 i PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: R AUTHORIZED AGVNT: Print Name: 4 i j LI [c7 /6- Mailing Address: 991/ — /3 V PLA cC SE Date: y27p Day Telephone: (ti 2S) . t%1 log IE(c6VVE City et-7/1 State 986 Zip IDate Application Accepted: M-L-7- 11) Date Application Expires: Staff Initials: V H: Wpplications\Fomis- Applications On Line \2010 Applications \7 -2010 - Remit Apphcation.doc Revised: 7 -2010 bh Page 6 of 6 PLUMBING AND GAS PIPING PERMIT INFORMATION — 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: State Zip Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: Valuation of Plumbs •. work (contractor's bid price): $ Valuation of Gas Pipin ork (contractor's bid price): $ Scope of Work (please pr •{ 'de detailed information): Building Use (per Int'l Building Code Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas pipin > outlets being stalled and the quantity below: Fixture Type: Qty Fixture Type: Q ; " Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or / water cooler (per head) , Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory r' 1 i ash fountain Receptor, indirect waste Sinks Urinals Wa' ,.. Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater ;+ d/or vent ' Industri .'t ante treatment intercepto", , eluding trap and vent, ex•z..t for kitchen type grease int", estors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repa'- ilr alteration of wat'; piping and/or water tr =: ent equipment Repair or alterati G oa,• f drainage or vent pip',,.. Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 : ackflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device' °, other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter ` Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in l lawn sprinkler backflow 1 protections (1 -5) / ' Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H \Applications \Forms - Applications On Une\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 5 of 6 • 0 City of Tukwila \z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: hto://wwwci.tukwila.wa.us RECEIPT Parcel No.: 7888920020 Permit Number: D10-287 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 10/27/2010 Applicant: VACANT SPACE Issue Date: Receipt No.: R10 -02175 Initials: User ID: WER 1655 Payment Amount: $464.52 Payment Date: 10/27/2010 10:39 AM Balance: $0.00 Payee: ANJALI WIG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 046738 ACCOUNT ITEM LIST: Description 464.52 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $464.52 278.80 181.22 4.50 doc: Receiot -06 Printed: 10 -27 -2010 C-f INSPECTION RECORD A ®�'. Retain a copy with permit kif INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project: t / �� Type � (1L ct • (�.i Address: rkay ailed : Special Instructions: Danted: _ a.m. Requester: A Phone No: Approved per applicable codes. .0Corrections• required prior•to approval. COMMENTS: pv- 1st/2A .pE INSPECTION FEE REQUIRED: Prior to next inspection; fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • Er 4 INSPECTION NO INSPECTION RECORD Retain a. copy with permit. , PERMIT CITY OF TUKWILA BUILDING DIVISION : • 6300 Southcenter #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Ot o -287 prot74.64.402—_ • Adidgii.57 0 S C•TArk-tA14,- • Special Instructions: r • Type pfAnspecnn: B 1: 1-4 i1/41w1 1-06‘rva Date Wanted: P.m. Requester: • I. /+4 e: j Corrections required prior•to approval. i PINQ pf 044-- 644 cej • 13) ittri Pitlintr RISivatvmk lInspenctor: Date: 1 z REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be - "--1 paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .9e AW.. • - t t•;71 C. "' •Ta$ 247&7'"Co 4 INSPECTION RECORD Retain a copy with permit INSPE TIIN NO. PERMIT'N0, CI 'Y OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila' WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 iv-_223 -? Project: 149 - !"r SrvistE r Type of Inspection: 6'il.,„1,o a..3 Lie /L.r/ Address: 7Z5". 0 12& 60/7"/PWVAeriv e i Date Called: • Special InsKructions: • • "6' ;re or /O, s•-i • • r c•4/667.5-.5--'6/ Date Wanted; . ,0 /_ V-I'1 p Requester' Phone No .a5'3- C —4,277 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: • icettaA -ki FS. J*4‘I\ — _ -_ b _ /r �yf��%. \ it / /���y 4 _.. 4aI _'- • (y' /i/�� �! • I -y }• ;, . .,4 • 1_ P., .0 . - r1 i. :s: _- . • 41.1.1 } '', .i ..��. s - . 4 . A i ' _- REINSPECTION FEE REQUIRED: Prior to next inspection, fee must bed .paid: at 6300 :Southcenter Blvd.: Suite 100. Call d schedule ieinspec ion. • f v^ ....x • -.1 , . ': .awi +r.�,r 2•••••70.41..". ..yam:. , +... •,9 .-:- r.'' '4 is a• . 'iY- :'!...... INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT • 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: „jj 5 -eit, SQL41412-0Z Tyy-pe of Inspection: clit)AL ( ci-f-e. ,. Address: 1)a s,.6 , )Xs' ' Suite #: N Contact Person: kiood & Duct: Special Instructions: Monitor: Phoneo.: 4 3 - 6 e 6 , 0 7 7 • Approved per applicable codes: nCorrections required prior to approval. COMMENTS: s f • -- Needs Shift Inspection: Sprinklers: r Fire Alarm: V . kiood & Duct: nl Monitor: f -Fire] ; Permits: gJ Occupancy Type: VLA CCn` - - -- Inspector:. . S '” . Date: 1/17) /if . Hrs.: • l • $80.00 REINSPECTION FEE REQUIRED.. You will receive an invoice from the City of Tukwila Finance Department. Call to •schedule a reinspection. Word/Inspection Record Forni.Doc 1/13/06 T.F.D. Form F.P. 113 r• •. .. • : - �+rw- t�r3�*±�� -ass- ,�3v =.!_._ _..�`� . �• ti 117 1�. INSPECTION RECORD Retain a copYrwith permit • INSPECTION NUMBER CITY OF TUKVNILA 'FIRE DEPARTMENT 444 Andover Park East Tukwila, Wa. 98188 ; . _ _ 206- 575- 4407 . PERMIT NUMBERS' Project: G��l o�'� L.. ! F Type of Insection: yp Inspection: • 1'x'2_ 50 Suite #: ! . ?lc Occupancy Type: Contact Person: IA bt 44.5- t'4u-i UAW Special Instructions: = Phone .No.: 7...3 - z 5 - (v .s7e ' • [LApproved per applicable codes. I Corrections required prior to approval. - COMMENTS: //7- Needs Shift Inspection : • Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: - . Permits: , Occupancy Type: Inspector :. 1 FAA 9'1 I Date: .11 " ,) I,- Hrs.::1. 6 $80.00 REINS'EC7ION FEE REQUIRED. You will receive an invoice from the -City of Tukwila Finance Department. Call to schedule ,a reinspection. . Word /Inspection Record Form.Doc 1/13/06 . T.F.D. Form F.P. 113 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address SOUTCENTER SQUARE, SPACE S -148 Date 10/26/2010 17250 SOUTHCENTER PARKWAY For Building Department Use COPY TUKWILA, WA 98188 FILE Applicant Name: FREIHEIT & HO ARCHITECTS, INC. Applicant Address: 10230 NE POINTS DRIVE sTE 300 KIRKLAND Felt NQ, Applicant Phone: 425- 827 -2100 Project Description Restroom ❑ Plans Included requirements. ❑ New Building ❑ Addition o Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area ALL Tenant space 1.50 2020.0 3030.0 Restroom Restroom 0.80 47.0 37.6 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3067. 6 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Tenant Space 2x4 Fluorescent 20 96.0 1920.0 Restroom 1x4 Fluorescent 1 54.0 54.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1974 .0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, tiff atta rrent limiting devices or of the transformer. REVIEW i • - • s res. For exempt lighting, note section and exception CODE COMPLIANCE U J 'ZUlU City of Tukwila BUILDING DIVIRION number, and leave Watts /Fixture blank. bLO2,B1 RECEIVED ED OCT 2'7 2010 PERMIT CENTER • tty of Tu 0 1 Jim Haggerton, Mayor Depart ent of Community Development Jack Pace, Director November 3, 2010 Anjali Wig 4811 134 PI SE Bellevue, WA 98006 RE: Correction Letter #1 Development Permit Application Number D10 -287 Vacant Space —17250 Southcenter Py — Suite 148 Dear Ms. Wig, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D10 -287 W:\Permit Center\Correction Letters\2010\D10 -287 Correction Letter ll I.DOC 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 Building Division Review Memo Date: Project Name: Permit #: Plan Review: Tukwila Building Division Dave Larson, Senior Plan Examiner November 1, 2010 Vacant Space D10-287 Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Per section 2903.1 of the Washington State Amendments to the 2009 International Building Code, separate toilet facilities will need to be provided for each sex unless the occupancy serves 15 or fewer persons. 7�e— `� S`% cpp I' <e., us-e 4.4=t.-a.e a - ±- 4 1(4;-, . 2. A means of egress aisle lighted per section 1006 IBC is required for this space and needs to run continuous between the front and rear exit, include emergency lighting per section 1006.3 and 1006.4 and be a minimum of 36 inches wide. Please show this path and code requirements noted on the floor plan or a separate egress plan. Pi, 3. Detail 2 on sheet A7.0 labeled acoustical ceilin hat channel typically used for a suspended provide current details for appropriate system. rid support is shown with cold rolled steel and Please confirm ceiling system proposed and • Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. RECEIVED NOV 08 2010 PERMIT CENTER • PE ii-ofir-DC PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -287 DATE: 11 -08 -10 PROJECT NAME: VACANT SPACE SITE ADDRESS: 17250 SOUTHCENTER PY - SUITE 148 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS:` U )C� 1` � Building' nj Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-09-10 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 12 -07 -10 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 I • 0 PE .fit;. C COY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -287 DATE: 10 -27 -10 PROJECT NAME: VACANT SPACE SITE ADDRESS: 17250 SOUTHCENTER PY - STE 148 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENT : ehA- buildin n ivl io P N4 Pubic Works tO Fire Prevention Ian Ing Ivision Structural Permit Coordinator J DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-28-10 Complete Comments: Incomplete n Not Applicable Permit Center Use Only I INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11-25-10 Approved n Approved with Conditions ❑ Not Approved (attach comments) [kr Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 3- ID IA Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: U/e Documents/routing slip.doc 2 -28 -02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #1100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: kl-s-to Plan Check/Permit Number: D 10-287 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Vacant Space Project Address: 17250 Southcenter Py — Suite 148 (� Contact Person: 141.0P\ W i Phone Number: 4)- 1 ` -7 I� M ) Summary of Revision: . e c' t c-' b"t NOV 08 2Q10 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date ofvision ` l Received at the City of Tukwila Permit Center by: Er- � Entered in Permits Plus on I H 0 \applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople liter Friendly Page 0 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ALLIANCE REMODEL & CONST LLC UBI No. 602891490 Phone 2536866277 Status Active Address 5621 228Th St E License No. ALLIARC917RT Suite /Apt. License Type Construction Contractor City Spanaway Effective Date 12/30/2009 State WA Expiration Date 12/30/2011 Zip 98387 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RIGHTTC0100ARIGHTTURN CONSTRUCTION Construction Contractor General Unused 9/1/1999 6/10/2011 Active ALLIARC019JG ALLIANCE ROOFING & CONST Construction Contractor Roofing Carpentry/Framing4 /7/1999 4/6/2000 Archived RIGHTTCO21QT RIGHT TURN CONSTRUCTION Construction Contractor Carpentry/Framing Siding 11/30/1998 11/20/1999 Archived RIGHTTC085Q3 RIGHT TURN CONSTRUCTION Construction Contractor Carpentry/Framing Dry Wall 11/23/1992 10/5/1993 Archived ALLIARC987DM ALLIANCE REMODEL & CONST Construction Contractor General Unused 3/14/2002 3/14/2004 Expired Business Owner Information Name Role Effective Date Expiration Date EDWARDSON, GREGORY DEAN Partner /Member 12/30/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100108571 12/29/2009 Until Cancelled $12,000.00 12/30/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 DEVELOPERS SURETY Et INDEM CO bis00001803 01 12/29/2009 12/29/2010 $1,000,000.0012 /30/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 11/12/2010 LANDLORD WORK SUITE S148 17250 SOUTHCENTER PARKWAY SUITE S148 SOUTHCENTER SQUARE SOUTHCENTER PKWY. & MINKLER BLVD. TUKWILA, WASHINGTON 98188 PLANNING APPROVED - No changes can be made to these plans without approval from the Planning Division of DClit Approved By: Date: R W ONS No '-nadta to the scope Tukwila Building approval of Revisions will require � Di�sion. and �y include ad i,j new plan subtotal plan review fees. SEPARATE PERMIT REQUIRED FOlt egethanissi Mauled City of Tukw�a BUILDING DIVISION COPY Penult AEI Pkei s r alltNd subjecttossusard omissions. App of =berm dues not Who's tix Vcldon of aq adophid codetroam& Rae * of awawadFlekl Gopy badge* * Dele City Made ISUILDING DIVISION Y_1Architectural Proiects11n131XA10 -36215 CURRENT PHASE DWGS12 Sheets1A10 -362 BLDG S -148 A01_dwa Oct 26_ 2010 - 1.21nm tsnader MEM CEO EME MME MEE MEM MEE EME MEM MEM EME COE ECM MEM MEM OEM EEO Ie MEM MEE MEE EME ECM MEM EEC E MEE MEM COE EME MEE MEM MEE MEM MEE Mee MME EEC MEE MEE MEE EEE MEE MEE MEE MEE EME MEE EME EME MEE MEE MEE EEO EEE MEE MEE MEE EME M MEE MEE EMM EME MEE MEE MEE MEM EEO MEE GEE MEE EEO MEM MEE MEE MEM COE EME MEM MEM CEO EME EEE ECM MEM EME EEO MEE MEM EEO EEC EEO MEM MEE EME EME MEM MEM COE EEO WEE MEM OEM EEO ECE MEM EME MEE MEE MOE MEE MEE MEE MEE EMM MEM COE EME MEM MEM COE COE MEM MEM EME EME EME MEM MEM MEE EME MEE MEM MEM EEO EME MEM MEM • E CNC ECM ECM WEE EME MEE MEM MEE EEC EMC MEE MEC EEC MEE MEE MEE MEE EME EME MEM MEM COE EME MEE MEM IEEE EME EME MEM MEM COE EME • M MEM MEE EME MME MEM EEM EEC EME MCC MEM EEC EEO MEE ECM MEE EME 0 N n N co Li In N 'Cr W I- 0 u u 0 X LI- m m 0 0o o, 5 ra 0 0 m d U▪ 7 cu 0` N c .o a W 0 m N O tn V 0 1= ■- ccM MEM EEC OEM MEM EEO EME MEM MEM CME EME EEC EEM EEE EEE OEM MEM men t EME EEO MEE MEE EEC EEC MEM MEM EME EEO MEC MEE IEEE EEO EEE MEM EEO E EM MEE OEM EEE MEE MEE EEC EMS OE M MEE EEO 141 /11 PROJECT NUMBER: XA10 -362 10126/10 ® FREIHEIT & HO ARCHITECTS, INC., P.S. 1.1 W co a C., W ▪ w z 111 g cn fg Zrg • WO B OWS • g rg • O O� U) U) O J 0 z 4 J 7812 REV DESCRIPTION REGISTERED ARCHITECT p WAS LE STATE OF WASHINGTON DATE A0.1 APPLICABL I L I N D VCN YMAP COD S X /j se �� -71-60e..1 7 ,[_ I' L�� e�� �T / ,, /� pep. �.•7- i 1r' �, i to / d-' -' 7`�!t �cc--� ce CSC_ CSC '- , G de_ /-6e BUILDING CODE - 20041 INTERNATIONAL BUILDING CODE PLUMBING GODS - 20041 UNIFORM PLUMBING CODE ELECTRICAL CODE - 2008 NATIONAL ELECTRIC CODE MECHANICAL CODE - 20041 INTERNATIONAL MECHANICAL CODE FIRE PROTECTION - 20041 INTERNATIONAL FIRE CODE ENERGY GORE - WAG BI-II WASHINGTON STATE ENERGY GODS HANDICAP CODE - 20041 I BC, AND ICC ANSI A 111.1 -2003 ARCHITECTURAL A -O.I COVER SHEET A -2.0 REFERENCE SITE PLAN A -3.0 FLOOR PLAN / DETAILS / SCHEDULES N ( :wr 1 PROJ DA A C _..sio . JO 7 4/, If fr2a /- he ,,/v � v �( v��'/- /, s " ' f 1:147477 ♦ -C61L._ l i'i4 <, efil / e.e/f5 O4 <i,Tfes S tell/ �/ b, , re-v e ewe- vh(eY- � - �,1,, -c VL:!,aA, , y� _/ ra-7p rt%ve-pv-! e G! � /' t:-�j / . '7"- t S T LOCATION: SUITE 5148, 1250 SOUTHCENTER PARKWAY, TUKWILA, WA ZONING: TUKWILA URBAN CENTER (TUC) OCCUPANCY: M, (MERCANTILE) NUMBER OF STORIES: I CONSTRUCTION TYPE: TYPE V -B, FULLY SPRINKLERED TENANT SQUARE FOOTAGE: SUITE SI48 2,061' S.F. OCCUPANT LOAD: 2,061 S.F. / 30 = 641 OCCUPANTS BUILDING SQUARE FOOTAGE: BUILDING 'N' 46,611 S.F. AGGESSORS PARCEL 1,401 F8E 262304ci080 262304'1081 2623044111/ DESCRIPTION OF WORK: DEMO EXISTING DEMISING WALL TO CREATE NEW SPACE. RELOCATE EXISTING ELECTRICAL PANEL. 'lINKL R BLVD I EY } O Q Z _ I \»III J SYMBOLS ABBR IONS G VIA N RAL NO S ALL SUB - CONTRACTORS MUST BE WORKING FROM A FULL WT OF DOCUMENTS. ALL SUB - CONTRACTORS TO VERIFY ALL DIMENSIONS FOR THEIR SCOPE OF WORK. IN EVENTS OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN PLANS AND SPECIFICATIONS, NOTIFY THE ARCHITECT IMMEDIATELY. NO MATERIALS OR PRODUCTS CONTAINING ASBESTOS ARE TO BE UTILIZED IN THIS PROJECT. NO PRODUCTS ARE TO BE UTILIZED IN THIS WORK THAT WILL REQUIRE SPECIAL INSPECTIONS OF HAZARDOUS MATERIALS SHOULD THEY BE REMOVED. ALL CONSTRUCTION SHALL CONFORM TO THE 2001 EDITION OF THE INTERNATIONAL BUILDING CODE. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH TIC= PLANS d PROJECT SPECIFICATIONS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN THE PLANS 4 SPECIFICATIONS, NOTIFY THE ARCHITECT IMMEDIATELY. FINISH FLOOR REF. DATUM EQUALS (100' -0"). REFER TO TOPOGRAPHIC SURVEY FOR ACTUAL SITE ELEVATION. ALL DIMENSIONS ARE TO FACE OF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES U.N.O. A WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD OF ANY SPECIES OR FOUNDATION LL GRADE CEDAR OR REDWOOD, ALL MARKED BY AN APPROVED TESTING, AGENCY. ALL WOOD FORMS USED FOR CONCRETE, IN THE GROUND OR BETWEEN FOUNDATION SILLS 4 THE GROUND SHALL BE REMOVED. PROVIDE HORIZONTAL FIREBLOCKIN6 IN ALL FRAME WALLS AT 101-0" O.G. 4 WHERE FRAME WALLS PENETRATE CEILING. FIREBLOCK IN ACCORDANCE WITH I.B.G. SECTION 1112. DRAFTSTOPPIN6 IN FLOORS 15 NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH SPRINKLER SYSTEMS IN ACCORDANCE WITH I.B.C. SECTION 103.3.1.1. (I.B.C. SECTION 111.33) DRAFTSTOPPING IN ATTICS 15 NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH IB.G. SECTION 4103.3.1.1. (I.B.C. SECTION 717.4.3) PROVIDE A FLOOR OR LANDING NOT GREATER THAN I" BELOW THRESHOLD AT ALL DOORWAYS. PROVIDE BLDG. ADDRESS PER OWNERS BUILDING STANDARDS. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. IB.G. SECTION 1008.1.1.1 HARDWARE. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER II SHALL NOT REQUIRE RIGHT GRASPING TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. LOCKS AND LATCHES PER IB.G. SECTION I008.I.g3. LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT OPERATION OF DOORS WHERE ANY OF THE FOLLOWING EXISTS: 2. IN BUILDINGS IN OCCUPANCY GROUPS M, THE MAIN EXTERIOR DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY -OPERATED LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: 2.1 THE LOCKING DEVICE 15 READILY DISTINGUISHABLE AS LOCKED, 2.2 A READILY VISIBLE DURABLE SIGN 15 POSTED ON THE EGRESS WHEN BUILDING 15 OCCUPIED. THE SIGN SHALL BE IN SIDE OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED W LETTERS I INCH HIGH ON A CONTRASTING BACKGROUND. ALL ROOMS OR AREAS HAVING AN OCCUPANT LOAD OF 50 (1,500 5F OF RETAIL SPACE) OR MORE SHALL HAVE AT LEAST 2 EXITS TO THE EXTERIOR OR TO AN EXIT CORRIDOR ( ONE -HOUR CONSTRUCTION). (IB.C. SECTION 1015.1 ) EXITS SHALL HAVE A MIN. SEPARATION OF ONE HALF THE MAX. OVERALL DIAGONAL OF THE BUILDING OR AREA SERVED, MEASURED IN A STRAIGHT LINE BETWEEN EXITS. (IB.G. SECTION 10152.1) EXCEPTION 2 - WHERE A BUILDING 15 EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER 5Y5T1 =M IN ACCORDANCE WITH I. SECTION 103.3.1.1 OR 103.3.12, THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT BE LESS THAN ONE -THIRD OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. EXPOSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS, SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE WALL OR CEILING SURFACE FINISH. (LB.G. SECTION 803) ELECTRIC RESISTANCE HEAT 15 NOT ALLOWED UNLESS THE WASHINGTON STATE NON - RESIDENTIAL ENERGY GODS COMPLIANCE FORM 15 REVISED. LIMIT AIR LEAKAGE PER W.S.E.G. SECT. 1314. WHEN THE FLOOR AREA OF 'GROUP B OR GROUP M' OCCUPANCIES EXCEED 3000 S.F., TWO BARRIER FREE RESTROOMS WILL BE REQUIRED. 26102.1.1 WASHINGTON STATE AMENDMENTS WHEN THE OCCUPANT LOAD EXCEEDS 50 THE DOORS MUST SWING IN THE DIRECTION OF EXIT TRAVEL. IBC SECTION 1008.1.2 DEAD END CORRIDOR IB.C. SECTION 1018.4 EXCEPTION 2: IN OCCUPANCIES IN GROUPS B AND F WHERE THE BUILDING I5 EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH IB.G. SECTION 4103.3.1.1, THE LENGTH OF DEAD END CORRIDOR SHALL NOT EXCEED 50 FEET (15240 MM) PROVIDE SUITE NUMBER ON MAIN ENTRY DOOR PER FIRE DEPARTMENT REQUIREMENTS. BUILDING SECTION < O t AND EQ. EQUAL O.G. ON CENTER. L ANGLE EQUIP. EQUIPMENT 0/ OVER AT EXIST. EXISTING OPP. OPPOSITE CENTERLINE EXPO. EXPOSED DIAMETER OR EXT. EXTERIOR PL. PLATE ROUND F.O.I.C. FURNISHED BY OWNER PLYWD. PLYWOOD L PERPENDICULAR INSTALLED BY CONT'R. P.P. POWER POLE * POUND OR NUMBER F.D. FLOOR DRAIN PLAM PLASTIC LAMINATE A.B. ANCHOR BOLT F.E. FIRE EXTING- ACOUS. ACOUSTICAL U15HER R. RADIUS OR RISER A.F.F. ABOVE FINISH FLR. F.H. FIRE HYDRANT R.D. ROOF DRAIN AGGR. AGGREGATE FIN. FINISH REC. RECOMMENDED ALUM. ALUMINUM FLASH. FLASHING REF. REFERENCE ANOD. ANODIZED FLR. FLOOR REINF. REINFORCED APPROX. APPROXIMATE FLUOR. FLUORESCENT REGD. REQUIRED ARCH. ARCHITECTURAL FOUND. FOUNDATION RM. ROOM ASPH. ASPHALT FRM'G. FRAMING FT. FOOT OR FEET 5. SOUTH BD. BOARD FTC. FOOTING 5.C. SOLID GORE BLDG. BUILDING FURR. FURRING SCHED. SCHEDULE BLK. BLOCK GA. GAUGE SHT. SHEET BLK'G. BLOCKING GALV. GALVANIZED SHT'G. SHEATHING BM. BEAM G.G. GENERAL CONTRACTOR SIM. SIMILAR BOT. BOTTOM GL. GLASS SPEC. SPECIFICATIONS B.U.R. BUILT UP ROOF CND. GROUND 50. SQUARE GR. GRADE STD. STANDARD CAB. CABINET GP. GROUP STL. STEEL G.B. CATCH BASIN G.W.B. GYPSUM WALL STOR. STORAGE GEM. CEMENT BOARD STRUG. STRUCTURAL CH. CHANNEL GYP. GYPSUM SUSP. SUSPENDED G.J. CONTROL JOINT 5.4 V. STAIN AND VARNISH CLG. CEILING HDWR. HARDWARE SVC. SERVICE GLR. CLEAR HDCP. HANDICAP SYM. SYMMETRICAL G.O. GLEAN OUT HDWD. HARDWOOD 5/104 SIDEWALK COL. COLUMN H.B. HOSE BIBB GONG. CONCRETE H.G. HOLLOW CORE T. TREAD CONN. CONNECTION H.M. HOLLOW METAL T.G. TOP OF CURB CONSTR. CONSTRUCTION HORIZ. HORIZONTAL TEL. TELEPHONE CONT. CONTINUOUS HR. HOUR T.4 G. TONGUE AND GROOVE G.T. CERAMIC TILE HT. HEIGHT THK. THICK GTR. CENTER T.O.P. TOP OF PLATE CTSK. COUNTER SUNK INST. INSTALLATION T.P. TOP OF PAVEMENT INSUL. INSULATION T.W. TOP OF WALL DBL. DOUBLE INT. INTERIOR TYP. TYPICAL DEPT. DEPARTMENT PET. DETAIL LAM. LAMINATED U.B.G. UNIFORM BUILDING PIA. DIAMETER LB. POUND GORE DIM. DIMENSION LOG. LOCATION UHF. UNFINISHED DN. DOWN U.O.N. UNLESS OTHERWISE DR. DOOR MATL. MATERIAL NOTED D.S. DOWNSPOUT MAX. MAXIMUM DWG. DRAWING MFR. MANUFACTURER VERT. VERTICAL M.H. MANHOLE E. EAST MECH. MECHANICAL W. WEST EA. EACH MIN. MINIMUM W/ WITH E.I.F.S. EXTERIOR INSULATION MISC. MISCELLANEOUS WD. WOOD FINISH SYSTEM MTD. MOUNTED WOW. WINDOW E.J. EXPANSION JOINT MTL. METAL W/O WITHOUT EL. ELEVATION W.P. WATERPROOF ELEC. ELECTRICAL N. NORTH M.R. .R. ATER RESISTANT ELEV. ELEVATOR N.I.G. NOT IN CONTRACT WSCT. WAINSCOT ENCL. ENCLOSURE NO. NUMBER WT. WEIGHT E.P. ELECTRICAL PANEL N.T.S. NOT TO SCALE L ON GAUD SCRIP A SECTION IDENTIFICATION A -3 NORTH ARROW D DESCRIPTION: PARCEL A: THAT PROTION OF THE NORTHWEST QUARTER OF THE SOUTH EAST QUARTER AND OF THE NORTHEAST QUARTER OF THE SOUTH WEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., DESCRIBED AS FOLLOWS; BEGINNING AT THE NORTHEAST CORNER OF THE SOUTHEAST QUARTER OF SAID SECTION 26; THENCE NORTH 88 °05'42" WEST ALONG THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF Igg8.6S FEET TO THE WEST LINE OF THE EAST 6134 FEET OF SAID NORTHWEST QUARTER OF THE SOUTHEAST QUARTER; THENCE SOUTH 01041'2q" WEST ALONG SAID WEST LINE A DISTANCE OF 658.25 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING ALONG SAID WEST LINE, A DISTANCE OF 662.05 FEET TO THE SOUTH LINE OF SAID NORTHWEST QUARTER OF THE SOUTHEAST QUARTER; THENCE NORTH 87 °55'02" WEST ALONG SAID SOUTH LINE, 666.56 FEET TO THE WEST LINE OF THE NORTHWEST QUARTER OF THE SOUTHEAST QUARTER; THENCE NORTH 01 °12'25" EAST ALONG SAID WEST LINE, 661.03 FEET; THENCE SOUTH 88 °00'36" EAST 673.30 FEET TO THE POINT OF BEGINNING; EXCEPT THAT PORTION CONVEYED TO THE CITY OT TUKWILA BY DEED RECORDED UNDER RECORDING NO. 1514082410525 FOR MINKLER BOULEVARD; SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. PARCEL B: THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., DESCRIBED AS FOLLOWS: I BEGINNING AT THE NORTHEAST CORNER OF TEH SOUTHEAST QUARTER OF SAID SECTION 26; THENCE NORTH 88 °05142" WEST ALONG THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF 2678.68 FEET TO THE EAST LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER; THENCE SOUTH 01 °12'25" WEST ALONG SAID EAST LINE 657241 FEET TO THE TRUE POINT OF BEGINNING; THENCE CONTINUING SOUTH 01 °12'25" WEST 661.03 FEET TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER; THENCE NORTH 87 °55'53" WEST ALONG SAID SOUTH LINE, 185.28 FEET; THENCE NORTH OI °58'21" EAST 54g.a5 FEET; THENCE NORTH 87 °55'53" WEST 48 FEET; THENCE SOUTH 02 °04'07" WEST 10 FEET; THENCE NORTH 87 °55'53' WEST 3'SAID CUR TO A TANGENT CURVE TO THE LEFT, WITH A RADIUS OF 25 FEET; THENCE SOUTHWESTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 410 °55'31" AN ARC DISTANCE OF 341.67 FEET;�D F� ° k� THENCE NORTH 01°0E5'55" EAST TO A ,POINT NORTH 88 0036 WEST FROM THE TUBE POINT OF BEGINNING; THENCE STOUTH 88 °00'36" EAST TO THE TRUE POINT OF BEGINNI6; +�� COMPLIANCE �� nVED EXCEPT THAT PORTION CONVEYED T THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. q i'. Y U ZOIU 14082410323 FOR MINKLER BOULEVARD; bL �/V� SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. Citj/Of Tul alp PARCEL C: BUILDING DIVISION THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., DESCRIBED AS FOLLOWS: RECEIVED BEGINNING AT THE NORTHEAST CORNER OF THE SOUTHEAST QUARTER OF SAID SECTION 26; THENCE NORTH' 88 °05`42" WEST ALONG THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF 2678.68 OCT 010 FEET FEET TO THE EAST LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER; THENCE SOUTH OI °12'25" WEST ALONG SAID EAST LINE 1518.32 FEET TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE SOUTHWEST QUARTER; PERMIT CENTER HENCE NORTH 81 °55155" WEST ALONE SAID SOUTH LINE, 18528 FEET TO THE TRUE POINT OF BEGINNING THENCE CONTUNUIN6 NORTH 81 °55'53" WEST 4341.12 FEET TO THE EAST RIGHT -OF -WAY LINE OF SOUTHCENTER • PARKWAY' THENCE NORTH 01 °08135" EAST 314.541 FEET ALONG SAID EAST RIGHT -OF WAY LINE TO A TANGENT CURVE TO THE RIGHT WITH A RADIUS OF 25 FEE; THENCE NORTHEASTERLY ALONG SAID CURVE THROUGH A CENTRAL ANGLE OF 410 °55'31°, AN ARC DISTANCE OF 341.61 FEET; THENCE SOUTH 87 °55'55" EAST 511.43 FEET; THENCE NORTH 02 °04'07" EAST 10 FEET; THENCE SOUTH 87 °55'55" EAST 48 FEET; THENCE SOUTH OI °58'21" WEST 344.15 FEET TO THE TRUE POINT OF BEGINNING; I 0 1 I I I . I I I ''--- LOCATED ON SHEET... WALL SECTION B < SECTION IDENTIFICATION ELEVATION MARKER 'a' -3 < LOCATED ON SHEET.. DETAIL DETAIL IDENTIFICATION FINISH GRADE ELEVATION O TOP OF CURB T A -5 < LOCATED ON SHEET INTERIOR ELEVATION .16.0 TOP OF PAVEMENT T 15.5 1 ELEVATION IDENTIFICATION A-1 < LOCATED ON SHEET ROOM SYMBOL CENTER LINE OFFICE ROOM NAME NUMBER 101 ROOM PROPERTY LINE ROOM MATERIAL CODES IA2 1st No FLOOR/BASE 2nd No WALLS /WAINSCOT 3rd No CEILING NEW CONTOUR q' - p" CEILING HEIGHT 12 GRID MARKERS < LETTERS IN ONE DIRECTION EXISTING CONTOUR - I5 - NUMBERS IN THE OTHER �f DOOR SYMBOL REVISION CLOUD DOOR NUMBER Q 4 DOOR MARK IDENTIFYING NUMBER © < WALL SYMBOL Pl WALL IDENTIFICATION WINDOW SYMBOL < WINDOW IDENTIFICATION GRAY LINES REPRESENT EXISTING TO REMAIN MATCH LINE BLACK LINES REPRESENT NEW OWNER: ARCHITECT: WIG PROPERTIES L.L.G. 5.5 FREIHEIT HO ARCHITECTS, P.S. 4811 -134TH PLACE 5E INC., ., 10250 NE POINTS DRIVE. SUITE 500 BELLEVUE WA 418006 ' KIRKLAND, WASHINGTON 41S055 PH: (425) 644 -6126 FAX: (425) 865 -8648 PH: (425) 827 -2100 FAX: (425) 828 -684141 E -MAIL: ANJALIWIGOWIGPROPERTIES.COM CONTACT: ANJALI WIG CONTACT: TOM SPADER SHADED PORTION I5 THE SIDE CONSIDERED - - DASHED LINES INDICATE EXISTING - - TO BE REMOVED Y_1Architectural Proiects11n131XA10 -36215 CURRENT PHASE DWGS12 Sheets1A10 -362 BLDG S -148 A01_dwa Oct 26_ 2010 - 1.21nm tsnader MEM CEO EME MME MEE MEM MEE EME MEM MEM EME COE ECM MEM MEM OEM EEO Ie MEM MEE MEE EME ECM MEM EEC E MEE MEM COE EME MEE MEM MEE MEM MEE Mee MME EEC MEE MEE MEE EEE MEE MEE MEE MEE EME MEE EME EME MEE MEE MEE EEO EEE MEE MEE MEE EME M MEE MEE EMM EME MEE MEE MEE MEM EEO MEE GEE MEE EEO MEM MEE MEE MEM COE EME MEM MEM CEO EME EEE ECM MEM EME EEO MEE MEM EEO EEC EEO MEM MEE EME EME MEM MEM COE EEO WEE MEM OEM EEO ECE MEM EME MEE MEE MOE MEE MEE MEE MEE EMM MEM COE EME MEM MEM COE COE MEM MEM EME EME EME MEM MEM MEE EME MEE MEM MEM EEO EME MEM MEM • E CNC ECM ECM WEE EME MEE MEM MEE EEC EMC MEE MEC EEC MEE MEE MEE MEE EME EME MEM MEM COE EME MEE MEM IEEE EME EME MEM MEM COE EME • M MEM MEE EME MME MEM EEM EEC EME MCC MEM EEC EEO MEE ECM MEE EME 0 N n N co Li In N 'Cr W I- 0 u u 0 X LI- m m 0 0o o, 5 ra 0 0 m d U▪ 7 cu 0` N c .o a W 0 m N O tn V 0 1= ■- ccM MEM EEC OEM MEM EEO EME MEM MEM CME EME EEC EEM EEE EEE OEM MEM men t EME EEO MEE MEE EEC EEC MEM MEM EME EEO MEC MEE IEEE EEO EEE MEM EEO E EM MEE OEM EEE MEE MEE EEC EMS OE M MEE EEO 141 /11 PROJECT NUMBER: XA10 -362 10126/10 ® FREIHEIT & HO ARCHITECTS, INC., P.S. 1.1 W co a C., W ▪ w z 111 g cn fg Zrg • WO B OWS • g rg • O O� U) U) O J 0 z 4 J 7812 REV DESCRIPTION REGISTERED ARCHITECT p WAS LE STATE OF WASHINGTON DATE A0.1 CL INTE STA 50 STA 45 a n WIG BOULEVARD WIG BOULEVARD TION NOR 38 S 411016111/411ENEMelialanter 0065111.- 111141114,6 1 , lirsiontilszitmanneemonsmassanninfireansii STA 63 +34.92 NORT STA 86 +57.90 EAST COMMEINammArmitimitffiNE inariairmrialMainganniarZNINNUMetnidelauggi �sVtr III�� BOWS ROM— IF F. ki_ MOW MOM MIMS sMiampitsi i samesstaisseamosit altla anor aIAre- , gem ggi 1121 `(mi l 1:11 11'.III�• a /I,Si ! JI�, V 1- $ '� 4 . mime Baum mudiiiiimmi m *� - � Y Y Q r Y r t . Y r r tH3 Y ,. • t- t H H H e r H" �� posoissom EMINIKINKO OM= I NM tr H o f H a AHYYf YnHY. 0 0 0 �;tr.t; 11U atrrrt :1111/1":11_111'i:' IAMB- MOM livimiONSIV 1rr ELF.ar a YY. �sY xQ UMW 9351 un HI •l 1 RI MA EL AIX PETCO �� flosiuminfailaati - -- —.. - -- - --- - - -- — _ - —. - - - - -- --- - - - - -- -- - - -- ------ - - - - -- - - : NORDSTROM S RACK I• Ir 'EN 'If!! I 3. I Km. 01� I !11 4 '� 4• T T O tr, : lI.r�- Yrrrrtrc'Yyo °Yrarr'. r 11� tr �IJI•� �� � �", rM1 HM1T F:'ttrCrryiy s � � a,. M1F- ,irT t , r s Y �!{i����iL.► 1 —,� tr r Y H rtrrrtr''HH °H ° "r °r 'HH�' ° Ir - ''''. 4. low I� ►� ��� 65�1�lRI I ' �I�F�i� '�`aIPi�fdi�s��ae�������IRF �°3�� 'alp !�1/.��.j� � H r �� � ���1�,1116il�a°f`�' AREA OF WORK m N IN SITE PLAN @ SUITE S148 SCALE: I" = 40' --REVIEWED FOR CODE COMPLIANCE APPROVED Nov 0 9 2010 City of Tukwila BUILDING DIVISION RECEIVED OCT 2 7 2010 PERMIT CENTER tto 281 MOM MOM MOM MEM MOM Mae Mee MEM MOM MOM MAO Mee MOM MOM MOM MOM Mae Mee MOM MOM MOM MOM MOM MOM MOM MOM Mee MOM MOM MOM MOM 6E MOM MOM MOM MOM MMM MOM MIME MOM MUM MOM MOM MOM MOM MOO MEM MOM MOM MOM MOM MOM MOM MOM MUM OMM MOM Mee MOM OEM MOM MOM MCC MOM MOM MOM MGM MOM MOM MOM Mee MOM MOM MOM MEM MUM MOM MOM MOM SOMM MOE MOM MOM MOM MOM MOM MGM MMM MOM MMM MOM MOM MOM MOM MOM MEM MOM MCC MOM MOM 6E Mae MMM MOM MOM OEM Mee MOM CCM OMM Mee OMM MOM MOM MEM Mina MOM MOSS lEMM MEM MEM MMM MOM MINS OMM MEM MEM MISO MOM MOM MUM CCM OMM MOM Mee MOM MEM SIMM MOM ONO MOM MOM mac MOM MOM MOM GOMM Mee OMM Mee SEMM MOM Mee MOM MOM MEM MUM OWE MOM OEM MOM ERE SEE EEE E ESE EEE EEE EEC MEE IEEE SEE ESE ESE SEE SEM SEE MEG SEE ESE SEE SEE 10230 NE Points Drive I Ste 300 I Kirkland I WA 1 98033 www.FHOARCH.COM TEL: 425 827 2100 O r Z V - V INN L C ■— 03 camY. Y:1Architectural Proiects11D131XA10 -36215 CURRENT PHASE DWGS12 Sheets1A10 -362 BLDG S -148 A20.dwa Oct 26. 2010 - 1:21nm tsnader OMM MEM OMB MOM OEM MEM MOM CCM e CCM 0E MOM 6E Mae MOM MOM MEM MOM MEM Mae MOM Mae Mee MOM MOM MOE Mee OEM MOM MOM MOM MMM O Mae COM MOM MOM MOM SOO COM ONO MOM MOO MOM COM MOM MOO M MMC OMM MOM MOM MOM OOM W 00 2 ci) 44g 8 ow N 0 W � calmm Z� WO BOWS I O� U) 0 J 0 z J 7812 REGISTERED ARCHITECT I D V.\140MAS L SPADER OF WASHINGTON REV DESCRIPTION DATE A2.O PROJECT NUMBER: XA10 -362 10126110 0 FREIHEIT & HO ARCHITECTS, INC., P.S. V•1A...L.4...d.....1 D...;e..Ir14YN41YA4/L'lR71R ('I IDDCAIT DIJACC 111A►('C17 CMenficleiniza9 RI nn 0_1AR AQn Awn nrt 9R 9nln _ 1.91nm fens ar I DOORSCHEDULE H DOOR NO MARK S�/THK W CC co g LL DETAIL FF = FACTORY FINISH 5*V = STAIN *VARNISH 5.G.= SEMI -GLOSS ANOD= FACTORY ANODIZED ALUMINUM REMARKS < z Z lit J ZLI co MARK A (EXISTING) 3'-O "x11 -O" A ALUM ANOD TEMP ALUM ANOD EXIST EXISTING DOOR, SEE REMARK #I BELOW — B (EXISTING) 3'- O "xl' -O" G SYt PAINT — H.M. PAINT EXIST EXISTING DOOR — G (EXISTING) 3' -0"x7' -O" B H.M. PAINT H.M. PAINT EXIST EXISTING DOOR — — DOOR TYPES 0 STOREFRONT NARROW STYLE GLASS O HOLLOW METAL DOOR WOOD DOOR Ihilh o EXTERIOR O INTERIOR SOLID INSUL. SAFETY DOOR REMARKS: I. PROVIDE DECAL SIGN WITH I" BLACK LETTERS READING: THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS. LOCATE ON INSIDE OF TRANSOM. 2. PROVIDE AND INSTALL 6" SQUARE INTERNATIONAL SYMBOL OF ACCESS SIGN ON WALL ADJACENT TO DOOR STRIKE. ROOM FINISH SCHEDULE F C FLOOR/BASE WALL/WSCT CEILING I SEALED CONCRETE A TAPED, SMOOTH 4 READY FOR PAINT I OPEN ABOVE 2 SHEE VINYL 13 TAPED, TEXTURED 6 PAINTED W/ SEMI - GLOSS PAINT 2 TAPED, SMOOTH 6 READY FOR PAINT 6" VINYL BASE 48" HIGH PLASTIC LAMINATE WAINSCOT 3 EXISTING TILE c 5 2x4 5U5P. A.G.T. WITH PLASTIC COATED TILES SEE SPEC. N .`_ 1• I 1\ { A/ \7( NOTES: I. REMOVE ALL EXISTING FIXTURES AND CA5EWORK. 2. REMOVE ALL EXISTING FLOORING IN VACATED SPADE. 3. ALL EXISTING PLUMBING PENETRATIONS IN FLOOR TO BE GAPPED. EXISTING DEMISING WALL TO BE REMOVED EXISTING COUNTERS TO BE REMOVED 1 1 EXISTING TENANT /WALLS TO BE REMOVED SUITE 148 (AREA: 2,067 S.F.) 148 3 EXISTING RESTROOM TO REMAIN A5 -I5 EXISTING ELECTRICAL PANEL TO BE RELOCATED EXISTING DEMISING WALL TO BE REMOVED Iq' -IO 1/4" In 3, -i 1/4" NEW LOCATION FOR RELOCATED ELECTRICAL PANEL 0 0 'S' BUILDING FLOOR PLAN @ SUITE 148 SCALE: I/4" 1' -0 _ " N 0 M1-12 4 8 FT. t) 0 1 — REVIEWED FOR CODE COMPLIANC *PPPAVED NUV 0 9 2010 i— City ofTukwi� BUILDING DIVISION RECEIVED OCT 2 7 2010 PERMIT CENTER MEM • 6L EEC GEM • 6E Rea EEC EEG WEE MEE MEE COE 6E EEC MEC MEE EME EEC MEE MEE ECG EOM MEC MEM Effie EME MEC MEC COE EME EEC ECM COE EME EEC MEM • 1N EEE EME EEC EEC Effie Effie EEC EEC MEM ECM EEC EEC MEM EEM COE e MEM MEM ECM ECM EEC MEC EEO EME EEC EEC MEC EEC EME EEC MEC Effie Effie EEC MEC EEC EEC CNN EEC MEM CNC CNN OEM MCC CNC CNC CNN CCM CCM CNC CNC CCM COM CCM CMC NOM MEM EE awn ace ace MCM CNC CNC CCM MCM CCM COE CCM COM MOM NEC CMC NCO MOM CMG COO CNN CCM CNC NEM CNN CCM Mee CCM COM COM COM • 6E Roc sem sec cow CNC CNC ECM Mee COM CNC WEE CCM is COM CNC Nee COM COM CNN NMM MCC MCC CNC COM Ec CCM CCM CNC CCM COM CNN CNC EE NEM MCM COM CMC CON CCM CNN CNC CON CCM CCM CNC CNC COM CCM CNC CNN CCM COM MCC CMC CNC MEM CCM NEM CNC CCM mum gee 10230 NE Points Drive I Ste 300 I Kirkland I WA 1 98033 www.FHOARCH.COM TEL: 425 827 2100 Ot,) w - V ■_ C13 c I NEN U cam CCM 6E MEC MEM ECM ECM MEC MEM ECM MOM GEC CCM ECM EME COM 6E MCC MEE OEM MEM CCE EME COM ECM MCC MEE MME ECC EEC MEE ECU ECE MEM COM 6E EME ECM COM COE MEE Mee MEM MOE CCM ECM e MME MEM ECM EEC MEM MOE CNC EC W CO co 12 ill ramom ar D ca • w rz hi' 111 • Wco Zrg • WO ce Ig CZ 0p ■ 0 O CI Z 7812 REGISTERED j ARCHITECT REV DESCRIPTION THOMAS If0 SPADER STATE OF WASHINGTON DATE A3.0 PROJECT NUMBER: XAIO -362 10/26/10 0 FREIHEIT & HO ARCHITECTS, INC., P.S. I MAIN RUNNER CROS5 RUNNER TO STRUI TURF ABOVE \41 r / DEGREES 41\MAX. , INSTALL #I2 GA. VERTICAL WIRE AT 4' -0" O.G. CONNECTED TO MAIN RUNNER AND STRUCTURE ABOVE. INSTALL #I2 GA. WIRE CR055 BRACING IN EACH PLANE OF MAIN RUNNER AT I2' -O" O.G. AT 45 DEGREE SHALL BE ANGLES IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6' -0" FROM EACH WALL. INSTALL A STRUT (I -5/8" MIN.) ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FT (3656 MM) ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FT (16241 MM) FROM EACH WALL. NOTE: I. INSTALL AS REQUIRED UNDER ASTM E580, ASTM 0635 AND ASTM 0636. 2. SUPPORTING WIRES TO BE GAUGED AND SPACED PER ASTM 0641 TABLE 3. 3. PROVIDE LIGHT FIXTURE SUPPORT ATTACHMENT PER ASTM E560. CEILING SPLINE BRACING SCALE: NOT TO SCALE 10 GA HANGER WIRES AT 4' -0" ON CENTER MAXIMUM EACH WAY (TYPICAL) CONTINUOUS ANGLE AT EDGE TYPICAL 6" MAX. 10 GA WIRE HANGERS AT PERIMETER SUPPORTING MAIN RUNNERS AND GROSS RUNNERS 8" MAX FROM EDGE. RECESSED LIGHT FIXTURE WHERE OCCURS 10 &A LATERAL BRACING WIRES 2' -0" MAXIMUM FROM CHANNEL INTERSECTION AT APPROXIMATELY 45° IN EACH DIRECTION. LOCATED ON A S' -0" X 12' -0" O.G. GRID AND A MAX. 6' -O" FROM WALLS. NOTE: PROVIDE I" X 2" CLOSURE ANGLE AROUND PERIMETER AT WALLS. MAIN RUNNERS: I I /2" COLD ROLLED CHANNELS AT 4' -0" ON CENTER MAXIMUM '7/8" X 22 GA GALV. HAT FURRING CHANNEL AT 16" O.G. MAX. ACOUSTIC CEILING 2 O ACOUSTICAL CEILING GRID SUPPORT �T SCALE: NOT TO SCALE EXISTING GYP. BD. CEILING AND SOFFIT TO REMAIN EXISTING EXIT LIGHT TO REMAIN. EXISTING CEILING GRID TO REMAIN. PROVIDE NEW BUILDING STANDARD CEILING TILE. PATCH AND REPAIR CEILING AS NEEDED. REMOVE EXISTING GYP. BD. CEILING AND REPLACE WITH ACT AND GRID. NEW 2X4 RECESSED FLUORESCENT LIGHTS, TYP. EXISTING GYP. BD. CEILING AND LIGHTING TO REMAIN NEW BUILDING STANDARD CEILING TILE AND GRID. O O EXISTING EXIT LIGHT TO REMAIN. 0 0 0 REVIEWED FOR CODE COMPLIANCE *PDP1VFD NOV 0 9 2010 City of Tukwila BUILDING DIVISION 'S' BUILDING REFLECTED CEILING PLAN @ SUITE 148 SCALE: I /4 "= I'-O" F141-1 LJ I N 2 4 8 FT. RECEIVED OCT 27 2010 PERMIT CENTER tt� z87 EME @ @@ EMM MEE MEE MEE EME MEM @@ MEM @@ MEM MEM MEM MOE Mee IEEE MEM ECM EMM MOM MEM MME EME EOM EOM MEM MEM EME EOM MEM MEE @@ MEE EEO EMM MEE EME MEM MEM MOE MEM MEM @@ MEE EME ECM MEM MEM MME EME MEM MEM MEE @@ MEM MEM MEM MOE GOO EEG EGE MGM CMG EWE EEM MEM GEM GMG MEM MEM EME MEE MOM OEM MGM MEG CMG EGG MGM MEM GEM EGO MEM MEM MEG GME EGE MGM MEM CMG EEC MEM MGM EOM EEO GEE EGO GEE EEG MEG MEM MEG GEE MEG MEE MME GME MEG ECM MEM MGM EEG CMG MEE MEM GEM ESE MOE @@ GEE GME EEG EGG EGG CMG nee GEC Mee MEM MEM CCU MEM Men Effie MEM MEM One Mee CEO WEN @@ Meg @@ Mee @@@ EEC MEM OEM @@ Mee ERE @@ MEE OEM COO ERE COO OEM @M EEO @@ MEM EEC MEE @@ COE COE MEM @ @@@ @@ OEM ESE MEC MEE EEC MEE @@ @@ @@ EEC OEM One MUM COE MEE EEC CO 10230 NE Points Drive I Ste 300 I Kirkland I WA 1 98033 www.FHOARCH.COM TEL; 425 827 2100 03 4' U triC EMU MEM EME EOM MEM MEM MEM EME MOM MEM MOM MEM @@ MEE MEM MOM SEEM MEM MEM MEE EMU MOE MEM @@ ECM EME EOM MEE MEM EME MEM MEM MEM MEE @@ EOM MSEM @@@ EME @@ MEE @@ EME MEE MEE @@ @@@ @@@ @@@ MEM @@ MEM EMM MEE ME REV DESCRIPTION HOAS I.kO SPARER STATE OF WASHINGTON REGISTERED ARCHITECT D. DATE A7.O PROJECT NUMBER: XA10 -362 10/26/10 0 FREIHEIT & HO ARCHITECTS, INC., P.S.