Loading...
HomeMy WebLinkAboutPermit D10-292 - ANDOVER DISTRIBUTION - ROOFANDOVER DISTRIBUTION 581 STRANDER BL D10 -292 City *Tukwi1a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Parcel No.: 0223300010 Address: 581 STRANDER BL TUKW Suite No: Project Name: ANDOVER DISTRIBUTION DEVELOPMENT PERMIT Permit Number: D10-292 Issue Date: 11/05 /2010 Permit Expires On: 05/04/2011 Owner: Name: REALTY ASSOCIATES FUND VII Address: 1301 DOVE ST #860 , NEWPORT BEACH CA 92660 Contact Person: Name: DON AUSTIN Address: 3601 S121 ST SW , LYNNWOOD WA 98087 Contractor: Name: COMMERCIAL INDSTRL ROOFING INC Address: 15331 HWY 99 , LYNNWOOD, WA 98037 Contractor License No: COMMEI *205JJ Phone: 425 754 -4046 Phone: 425- 745 -8148 Expiration Date: 05/16/2011 DESCRIPTION OF WORK: INSTALL FIRE RATE SEPARATION SHEET OVER EXISTING BUR ROOF MEMBRANE AND APPLY NEW TPO SINGLE -PLY ROOF MEMBRANE. INSTALL NEW COPING AND COUNTER FLASHING METAL. Value of Construction: $274,000.00 Fees Collected: $4,801.71 Type of Fire Protection: SPRINIC,ERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0025 * *continued on next page ** doc: IBC -10106 D10 -292 Printed: 11 -05 -2010 City uiTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10-292 Issue Date: 11/05/2010 Permit Expires On: 05/04/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: U' — G I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p construction or th Signature: Print Name: does not pr ume to give authority to violate or cancel the provisions of any other state or local laws regulating uthorized to sign and obtain this development per rformance of wo '3\A/ / S Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -292 Printed: 11 -05 -2010 wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 0223300010 Address: Suite No: Tenant: 581 STRANDER BL TUKW ANDOVER DISTRIBUTION PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D10 -292 ISSUED 10/29/2010 11/05/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 D10-292 Printed: 11 -05 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or thermance o • ork. Signature: ` Date: Print Name: doc: Cond -10/06 D10 -292 Printed: 11 -05 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://Www.ci.tukwila.wa.us Building Permit No. 1 I 0— 2A E Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 581 Strander Blvd. Tukwila WA Tenant Name: Andover Distribution Property Owners Name: GVA Kidder Mathews Mailing Address: 500 108th Ave NE, Bellevue WA 98004 King Co Assessor's Tax No.: 021 O"OOt G Suite Number: Floor: New Tenant: ❑ Yes I ..No City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Don Austin Mailing Address: 3601 121st Street SW Lynnwood WA 98087 Day Telephone: (425) 754 -4046 E -Mail Address: don @cir- roofing.com City State Fax Number: (425) 423 -0992 Zip GENERAL CONTRACTOR INFORMATION – (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Commercial Industrial Roofing Mailing Address: 3601 121st Street SW Lynnwood WA 98087 Contact Person: Don Austin E -Mail Address: don @cir- roofing.com Contractor Registration Number: COMMEI *205JJ City State Day Telephone: (425) 754 -4046 Fax Number: (425) 423 -0992 Expiration Date: 05/10/2011 Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: city Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications Fonns- Applications On [ine\2010 Apptications17 -2010 - Permit Applicatioo.doe Revised: 7 -2010 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 • BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ Z 7; Existing Building Valuation: $ Scope o Work (please provide detailed information): Will there be new rack storage? ❑ Yes ea. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15t Floor 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: AGENT: Print Name: Don Austin Mailing Address: 3601 121st Street SW Lynnwood WA 98087 IDate Application Accepted: 12A to Date: /6/2—? /76-) Day Telephone: 425- 7544046 City Date Application Expires: H: Applications\Forms- Applications On Iine12010 Applications\7 -2010 - Permit Application.doc Revised: 7 -2010 bb i9-4\ State Zip Staff Initials: r/i,�� (.. Page 6 of 6 I City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci. tukwi la. wa. us Parcel No.: 0223300010 Address: 581 STRANDER BL TUKW Suite No: Applicant: ANDOVER DISTRIBUTION RECEIPT Permit Number: 1)10-292 Status: PENDING Applied Date: 10/29/2010 Issue Date: Receipt No.: R10 -02194 Initials: JEM User ID: 1165 Payment Amount: $4,801.71 Payment Date: 10/29/2010 08:40 AM Balance: $0.00 Payee: COMMERCIAL INDUSTRIAL ROOFING, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 039492 4,801.71 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $4,801.71 2,907.40 1,889.81 4.50 doc: Receiot -06 Printed: 10 -29 -2010 • • Prod ct: AIL i 6btr r �,., Type o Inspection: • • �; ;,. (d t& a i s i owl ,b-► Address :, �+- S y , Date Called: ns: Instructions: Special In ".!1 , 1.)d-flex Date Wanted: le—ii - - Requester: Phone No: _ _ 42S - `?54 -4 '43 Approved per applicable codes. . DCorrections required prior to approval.. • COMMENTS: i I Mi-rifoitApilit nspec or: • n REINSPECTION FEE REQUIRED. Prior to next nspection.'fee must be paid at.6300 Southeenter Blvd.. Suite 100: Call o schedule'reinspection.. Johns Manville Building Owner The Realty Assoc. Fund VII do GVA Kidder Mathews Charlotte, NC 28216 Building Name Andover Distribution Center 551 Strander Boulevard Tukwila, WA 98188 Approved Roofing Contractor Commercial Industrial Roofing, Inc. 3601 121st Street SW Lynnwood, WA 98087 ommercial /Industrial Roofing Systems 4 Peak Advantage Guarantee ,Q ( D 2_9#?____ Guarantee Number: ANTI51083891 Date of Completion: 12/23/2010 Terms & Maximum Monetary Obligation to Maintain a Watertight Roofing System. Years 20 No Dollar Limit Coverage The components of the Roofing System covered by this Guarantee are: Total Squares: 800 Membrane Spec. and Type . Mechanically Fastened -ST6RM TPO Insulation Type Accessories (Type and Quantity) None ,None ,None frJ�rPr�r�rJrJ�r�rJrJ�rJ�rPrJ�rJ�rJ�rPrJ�r�cPrJ�rJ�rJ�rJrJ�rJ�rJ�rJ�rJ�r�r�rPrPrJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�cPrJ�rJ�rJ�rJ�rJ�rJrJ�r�r�rPrJ�rJ�rJ�rJ�rJ�rJ�rJrJ�rJ�rJ�rJ�r�rPrJ�r�rJ�rJ�r�rlrJ�rPrJ�rJ�rJ�rJ�rJ�r�rJ�rPcr 1' O 'these Johns Manville Guaranteed components are, referred to below as the "Roofing System" and ALL. OTHER COMPONENTS OF THE OWNER'S BUILDING ARE EXCLUDED FROM THE TERMS OF 'rills GUARANTEE. Johns Manville' guarantees to the original Building Owner dint doting the Term commencing with the Date of Completion. JM will pay for the materials and labor required to promptly repair the Roofing System to return it to a watertight condition if leaks occur due to: ordinary wear and tear, or deficiencies in any or all of the component materials of the Rooting System, or workmanship deficiencies in the application of the Roofing System. WI IA'I' 'RID() IF YOUR ROOF LEAKS If you should have a roof leak please refer to directions on the reverse side. l.IMffATIONS AND EXCLUSIONS, 'Ibis Guarantee is not a maintenance agreement or an insurance policy; therefore, routine inspections and maintenance are the Building Owner's responsibility (see reverse side of this document). Failure to follow the Maintenance Program on the reverse side of this document nni!! void the Guarantee. This Guarantee does not obligate JM to repair the Rooting System. or any pant of the Rooting System, for leaks resulting from (a) natural disasters including but not limited to the direct or Indirect effect of lightning. flood, hail storm, eutthquake, tornados, hurricanes or other extraordinary natural occurrences and /or wind speeds in excess of 72 miles per hour, (b) misuse, abuse or negligence. (c) instillation or material failures other than those involving the component materials expressly defined above as the Roofing System or exposure of the Roofing System components to damaging substances such as oil or solvents or to damaging conditions such as vermin, (d) changes to the Roofing System or the Building's usage that are not pre - approved in tnriling by .IM, or (e) failure of the Building substrate (mechanical, structural, or otherwise and whether resulting from Building movement. design defects or other causes) or improper drainage. JM is not responsible for leaks and damage resulting from water entry front any portion of the Building structure not a part of the Roofing System. I his Guarantee becomes ellcetive when (I) it is delivered to Owner: and (2) all bills for installation, materials, and services have been paid in full to the Approved Roofing contractor and to JM. Until that time, this Guarantee is not in force and has no effect. 'I he Parties agree that any controversy ur claims relating to this Guarantee shall be first submitted to mediation under the Construction Industry Arbitration and Mediation Rules of the American Arbitration Association (Regular Track Procedures) or to such other mediation arrangement as the parties mutually agree. No court or other tribunal shall have jurisdiction until the mediation is completed. TO .1.111; Ft11.I.EST EXTENT PERMITTED BY LAW, JM DISCLAIMS ANY IMPLIED WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY AND I't II: WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND LIMITS SUCH WARRANTY TO THE DURATION AND TO THE EXTENT OF THE EXPRESS WARRAN I Y ('ON IAINLD IN THIS GUARANI EE. 11ll{ EXCLUSIVE RESPONSIBILITY AND LIABILITY OF JM UNDER THIS GUARANTEE IS TO MAKE REPAIRS NECESSARY TO MAINTAIN TIIE ROOFING SYSTEM IN A WA'fl :RTIGII'f CONDITION IN ACCORDANCE WITH THE OBLIGATIONS OF .IM UNDER THIS GUARANTEE. .IM AND I'rS AFFILIATES WI1..1. NOT BE I.IAI3LE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES TO THE BUILDING STRUCTURE (UPON WIiICH 'rl If ROOFING SYSTEM IS AFFIXED) OR ITS CONTENTS, LOSS OF TIME OR PROFITS OR ANY INCONVENIENCE. JM AND ITS AFFILIATES SHALL NOT BE LIABLE FOR ANY DAMAGES WHICH ARE BASED UPON NEGLIGENCE, BREACH OF WARRANTY, STRICT LIABILITY OR ANY OTHER THEORY OF I.IA13ILIfY OTHER TI IAN THE EXCLUSIVE LIABILITY SET FORTH IN THIS GUARANTEE. No one is authorized to change, alter, or modify the provision of this Guarantee other than the Manager, Guarantee Services Unit or authorized delegate. .IM's delay or failure in enforcing the terms and conditions contained in this Guarantee shall not operate as a waiver of such terms and conditions. This Guarantee is solely for the benefit of the Building Owner identified above and Budding (wner's rights hereunder are not assignable. Upon sale or other transfer of the Building, Bolding Owner may request transfer of this ( inar :uaee to ate, new owner. and JM may transfer this Guarantee, in its sole discretion only after receiving satisfactory information and payment of a transfer fee. which must be paid no later iluu 31) days alter the date of Building ownership transfer. In the event .IM pays for repairs which are required due to the acts or omissions of others, JM shall be subrogated to all rights of recovery of the Building Owner to the extent of the amount ofthe.repairs. Because JM does not practice Engineering or Architecture, neither the issuance of this Guarantee nor any review of the Building's construction or inspection of roof plaits for the Building's roof deck) by JM representatives shall constitute any warranty by JM of such plans, specifications, and construction or in any way constitute an extension of the tenon and conditions of this Gutuantee. Any roof inspections are solely for the benefit of JM. JM dues not supervise nor is it responsible for a roofing contractor's work except to the extent stated herein, and roofing contractors are not agents of Jhi. •JOI INS MANVILLE ( "JM ") is a Delaware corporation with its principal mailing address at P.O. Box 5108, Denver, Colorado 80217 -5108. I�rJ�rJ�r�rlrPrJ�r�rJ�rJ�rl) cPrPcPrJ�rPcPrJ�rJ�rJ�rJ�cPrJ�rJ' cPcPt�cPrJ�cPrJ�rJ�r- Pr. J�r�r. Pf�cPrJrJ�rJ�rJrJ�rJ�rJ�rJ�rJ�rJ�rJ�r�r�r�rJ�rJ�rJ�rJ�rJ�c. PrJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�rJ�cPrJ�rJ�r. PrJ�rJ�rJ�rJ�r .PrJ�rJ�rJ�cPcPcPc.PrJ�rJ�r1 O By : Fred Stephan Title : Vice President & General Manager Roofing Systems Group Attorney -in -Fact 1 tat, V ER U Is-rta.i stAT1OA) S I Sii Ai4bE 3LvD Tvow,J i LJA VA. Lo ' tz oft =�c.� 0 a D SEPARATE PERMIT REQUIRED FOR: cal El Eta ti Plumbing I-Gas Piping City of Tukwila BUILDING DIVISION 0 0 • n D • 0 FILE COPY Pont* No. NO Plan fevldw approval Is autjett to etrom and antsslons. Approval of oonMnstion documents does not au hole the violation of code /ordnance. of cams Is acknowledged: Of Tukwila MOLDING DIVISION 0 I- REVISIONS Nowithout e made to the econe Tukwila Building OMsi approval of NOTE Revisions will require a new plan subm!t -I and may include additional plan review f-;.:,. REVIEWED FOR CODE COMPLIANCE ponnvED NuV 03 2010 Co la BUILDING i VISION RECEIVD CITY OF TU LA OCT 2 9 2010 PERMIT CENTER P10-2612 MAPOVESI Notes ALE CO Map of 581 Strander Blvd Tukwila, WA 98188 -2920 o tt0om, o 1 300 ft Evans Black Or Baker Blvd p Track Dr mapquest it 1;�13`ry All rights reserved. Use subiect to License /Copyright I Map Legend Page 1 of 1 --REVIEWED FOR COMPLIANGE APPPDVED NOV 03 2010 B of Tukwila BUIL ING DIVI,sinN 02010 MapQuest PortionsiEF010 NAVT4Q Directions and maps are informational only. We make no warranties on the accuracy of their content, road conditions or route usability or expeditiousness. You assume all risk of use. MapQuest and its suppliers shall not be liable to you for any loss or delay resulting from your use of MapQuest. Your use of MapQuest means you agree to our Terms of Use http: / /www.mapquest.com/print KECEIV D r'lTv OF TU LA `p I,1:1 ? 9 2010 PERMIT CENTER GL-2172, tf,0„ IlLt. A010' m,.430.1,43, N. 9`LI,..1Zat „ 4 vh .71 tt...:•'"'"mwistplogfs-.; ,•• BRUCE ARNOLD P.E. RESIDENTIAL AND COMMERCIAL ENGINEERING Barnold,40(a)vahoo.com 253 838 7737 r\>-. c.)Vkl=-: L.? f_o / r -2-, // 7- p‘A 7 • PREPARED BY /ft •••••••••. ji 1-4 I 1.-)C3 A e --"likTLE-Comp REED FOR - CODE COIVIEWPLIANCE APPROVED Nov 0 3 2010 City of Tukwila BUILDING DIVISinhi r 7;44 / (/J CITYIRLA 29 2010 PERMIT CENTER PROJECT .5c9 / 37:e4tio(_6-4 DATE 49/06 79 SUBJECT Ec-' 20 0 F.- 7 SHEET NO. / OF_ j JOB NO. 1710- 2212_ NON - RESIDENTIAL RE -ROOF ENGINEER'S CERTIFICATION FOR A SINGLE OVERLAY Afia. Maximum two (2) roofs. Three (3) roofs not allowed. L E tips- ta hereby certify that the roof structure located at 5 c ('12 /) r..i C F2 l l- V 6 , meets the following requirements; The roof structure is sufficient to sustain the weight of the additional dead load of the new roofing based on the design values contained in the 2006 International Building Code. The roof deck is structurally sound. 0 Roof drains and drainage are sufficient to prevent extensive accumulation of water. The existing roofing is securely attached to the deck. 11)11 The existing insulation is not water soaked. The fire- retardant requirements are maintained. Signed Affix Seal Washington Sta e registered Professio ' al State of Washington Date z ,// 0 WH 1-2 bsd 1073 6/26/07 p. 2 of 2 Page 1 of 1 DonA slin From: Janell Simpson [janell.simpson©convoy-supply.com] Sent: Thursday, October 28, 2010 7:53 AM To: 'Glen Anderson'; Don Austin Subject: FW: JM TPO - Atlas FR -10 Slip Sheet Fire Rating. Don & Glen, Here is a copy of the approval for FR10 & JM TPO...you are good to go © From: Mayer, Brian [mailto:Brian.Mayer @jm.com] Sent: Wednesday, October 27, 2010 3:55 PM To: 'Janell Simpson' Subject: JM TPO - Atlas FR -10 Slip Sheet Fire Rating. Roofing Systems See General Information for Roofing Systems ATLAS ROOFING CORP SUITE 800 2000 RIVEREDGE PKY ATLANTA, GA 30328 USA MAINTENANCE AND REPAIR Class A, B or C R13089 1. Deck: C -15/32 Incline: 1 -1/2, See Note Existing Roof System: — Any UL Classified Class A, B or C roof system to maintain existing classification. Slip Sheet: — One layer "FR -10," mechanically fastened. Roof Covering: — Any BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO, EIP or THE membrane system. Note: Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck, but not to exceed 1-1/2 in. slope. Brian A. Mayer • Sales Representative Johns Manville • Roofing Systems • A Berkshire Hathaway Company 425 - 271 -2664 Phone • 866 -243 -5313 Fax • brian.mayer @jm.com www.im.com /roofing 10/28/2010 -FILE COPY Johns Manville JM TPO Roofing Membrane - 60 mil Description JM TPO thermoplastic polyolefin (TPO) membranes are reinforced with a polyester fabric and designed for use in mechanically fastened and adhered roofing applications. Use Install JM TPO Membranes in new, re -roof (tear -off) and re -cover roof constructions. In re -cover constructions, if the existing roof is sound, the single ply membrane can eliminate the cost of disposing the origi- nal roof. Colors White, Grey and Tan The custom colors below are available upon request and may be sub- ject to minimum requirements and lead times. Standard Sizes Color White 5' x 100' (1.52 m x 30.48 m) 8' x 100' (2.44 m x 30.48 m) 10' x 100' (3.05 m x 30.48 m) Grey* and Tan* 5' x 100' (1.52 m x 30.48 m) 8' x 100' (2.44 m x 30.48 m)* 10' x 100' (3.05 m x 30.48 m) *Grey and Tan 8 -ft (2.44 m) sheet lead times are subject to availability and may require an upcharge for smaller projects. JM Peak Advantage Guarantees Enhanced guarantees are now available on certain systems for wind and puncture. Consult your local sales representative for more infor- mation about the new Single Ply Guarantee Charges Requirements Guide for specific guarantee terms and costs. Product Mechanically Fastened or Fully Adhered JM TPO 60 5, 10, 15 or 20 year JM TPO Membranes meet or exceed all of the requirements of ASTM D 6878. Tested Physical Properties' Installation Since JM TPO Membranes are thermoplastic, they can be rolled out onto the roof substrate and easily welded into one homogeneous sheet using hot -air welding procedures. JM TPO Membranes can be mechanically fastened or adhered to the structural roof deck. Application must be in accordance with FM Global® requirements, building codes, and published standard fasten- ing patterns or adhesives recommendations. Install JM TPO products in accordance with current JM TPO Applicator Guides or Detail Drawings. Approvals JM mechanically fastened and adhered TPO roof systems are classified by UL® (Underwriters Laboratories Inc.) and FM Global (Factory Mutual). When searching in RoofNav for a specific approval, be sure to indicate the mil thickness desired, i.e., JM TPO 60. Energy and the Environment CRRC® Initial Reflectivity: 0.77 Emissivity: 0.87 California Title 24 Pass Reflectivity: 0.77 Emissivity: 0.87 ENERGY STAR® Initial Reflectivity: 0.78 3 Yr. Aged Reflectivity: 0.68 Cleaned 3 Yr. No LEED® SRI of 101 as tested by ASTM E 1980. Recycled Content Postconsumer: 0% Postindustrial: 11% Producing Locations: Scottsboro, AL Results shown are for the initial reflectivity and eminence for indicated; emissivity values for California Title 24 are tested p tested per ASTM E 408. bhite m erwise� �"� FOR CODE COMPLIANCE APPROVED NOV 0 3 2010 City ofTukwila ON Property ASTM Test Method ASTM Requirements •- 6ttiVlii ter, • • v ug b/1 W Ii MD** XMD** Overall Sheet Thickness D 751 >0.039 in. (1.0 mm) 0.060 in. (1.52 mm) Thickness of Coating Over Fabric Weather Side D 6878 >0.012 in. (.305 mm) 0.027 in. (.69 mm) Breaking Strength D 751 >220 lbf (978 N) 325.83 lbf (1,449.36 N) 335.731bf (1,493.40 N) Elongation at Reinforcement Break D 751 >15% 42.41% 34.93% Tearing Strength D 751 >55 lbf (245 N) 89.8 lbf (339.45 N) 184.6 lbf (821.14 N) Brittleness Point D 2137 -40 °C (-40 °F) Pass @ -40 °C ( -40 °F) Ozone Resistance D 1149 No Cracks Pass Heat Aging (Pass /Fail) D 573 Pal:FCFItJED Pass " MD: Machine Direction XMD: Cross Machine Direction ' Physical testing performed one typical 10' (3.05 m) wide membrane CITY OF TUr( V VILA OCT 2 9 2010 PERMIT CENTER 7 -10 (Re 2ffia JM TPO Roofing Membrane —60 mil Johns Manville JM TPO Membranes meet or exceed all of the requirements of ASTM D 6878. Tested Physical Properties' Property ASTM Test Method ASTM Requirements 60 Mil MD** XMD** Post Heat Aged Breaking Strength D 751 >90% retained values 328.14 lbf (1,459.64 N) 334.16 lbf (1,486.42 N) Post Heat Aged Elongation at Reinforcement Break D 751 >90% retained values 39.10% 35.14% Post Heat Aged Tearing Strength D 751 >60% retained values 77.1 lbf (342.96 N) 245.0 lbf (1,089.81N) Post Heat Aged Weight Change D 1204 ±1% max. <0.1% Post Heat Aged Linear Dimension Change D 6878 ±1% max. <0.1% Water Absorption D 471 ±3.0% max. 2.20% Factory Seam Strength 0 751 >66 (294) 140.48 lbf (624.89 N) Post Xenon Visual Inspection D 6878 Pass Pass " MD: Machine Direction XMD: Cross Machine Direction Supplemental Testing 'Physical testing performed on a typical 10'13.05 m) wide membrane Property ASTM Test Method ASTM Requirements 60 Mil Dynamic Puncture D 5635 N/A 27.5 Joules Static Puncture D 5602 N/A Pass @ 44 lb (20 kg) Reflectance C 1549 N/A 80.78% Emittance C 1371 N/A 0.86 Resistance of Synthetic Polymer Material to Fungi G 21 N/A 0 rating Puncture Resistance (FTMS 101C, Method 2031) N/A N/A 371 lb (168 kg) Moisture Vapor Transmission E 96 N/A 0 g/m2 per 24 hours Hydrostatic Resistance, Mullen D 751 N/A 540 PSI (3723 kPa) Refer to the Material Safety Data Sheet prior to using JM TPO. Material Safety Data Sheet is available by calling (800) 922 -5922 or on the Web at www.jm.com/roofing. RS- 8633web 7 -10 (Replaces 6-101 FIRE RETARDANT SLIPSHEETS ATLAS -> FIRE RETARDANT SLIPSHEETS FR -10 and FR -50 fire resistant slipsheets enhance the overall fire performance of many conventional commercial roof systems, including metal roofs. FR -10 and FR -50 are coated -glass fiber mats specifically designed for installation over wood decks or certain combustible insulation. fR -50 incorporates a heavier glass mat than FR -10 to provide enhanced fire performance. • Superior protection against flame spread and penetration. - A lightweight and easy - to-install roof system component. - Part of a "Class A" assembly over noncombustible decks and expanded polystyrene • Part of a "Class A" assembly over combustible and noncombustible decks and extruded polystyrene FIRE-RETARDANT SLIPSHEETS RECOMMENDED USES FR -10 and FR-50 are specifically formulated for use over wood decks or polystyrene insulation. The proprietary flame - retardant coating and glass -fiber mat provide protection against flame spread and flame penetration through the roof system. The slipsheet can also act as a barrier between chemically incompatible insulation and roof membranes. In addition, the sheet may be used in multiple layers to achieve certain Class A fire resistance ratings. > INSTALLATION Atlas Fire Retardant Slipsheets are lightweight, easy to handle and, therefore, quicker to install than thermal barriers or coverboards. The slipsheet should be rolled out, overlapping the side and end of the preceding sheet a minimum of two (2) inches. Consult the membrane manufacturer for specific application recommendations (e.g., slipsheet roll direction perpendicular to membrane roll). Mechanical attachment of the slipsheet is not needed in most applications. The patented coating generally provides enough weight to anchor the sheet until the membrane is installed. Mechanical or adhesive attachment maybe necessary under windy conditions. Install only as much slipsheet as can be covered by the end of the day. a STORAGE Factory - applied packaging is intended solely for protection during transit. When stored outdoors or on the job site, the slipsheet rolls should be stacked on pallets at least four inches above ground level and completely covered with a weatherproof covering such as a tarpaulin. +WARRANTY AND LIMITATION OF LIABILITY Other than the aforementioned representations and descriptions, Atlas Roofing Corporation (hereafter, 'Seller") makes no other representations or warranties as to the product sold herein. The Seller disclaims all other warranties, express or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. The Seller shall not be liable for any incidental or consequential damages including the cost of installation, removal, repair or replacement of this product, insulation and /or roof membrane, etc. The Buyer's remedies shall be limited exclusively to, at Seller's option, the repayment of the purchase price or resupply of product manufactured by Atlas in a quantity equal to that of the nonconforming product. Atlas distributors, agents, salespersons, or other independent representatives have no authority to waive or alter the above limitation of liability and remedies. This product is covered by one or more US and foreign patents. t Slipsheet fdr RodAngSystedisas �to t} an Eictemal Fire Exposure only. -See: �Ul DuetoryofProuctertefor,;i (Canada and UL Roofing Materials & Systems Directory `• =` r t, _? >s` Miami -Dade County, Florida , NOA No. 05-0602.03, 10/20/10 MIAMFDADECOUNTY APPROVED ATI-080450-00 P110 FH50 DataSheet V11.indd 1 FIRE RETARDANT SLIPSHEETS +APPLICATIONS TYPICAL COMBUSTIBLE DECK/METAL ROOF APPLICATION TYPICAL COMBUSTIBLE DECK APPLICATION TYPICAL NON-COMBUSTIBLE DECK APPLICATION MEMBRANE FASTENER SINGLE -PLY MEMBRANE FR SLIPSHEETS THERMAL BARRIER (GYPSUM BOARD) EXPANDED OR EXTRUDED POLYSTYRENE INSULATION +TECHNICAL DATA -- .. .. .... .. IRNUAIU �MLt). .. _. , .. os. 11,4,7, Lp SLIP'SHEET,s 4 ' .U.'-, v } "W-rtt 'SQUARES; PER ROLL" r.e ∎." '':;4;ak'�t . ,4 (OVERAGE W /2 LAP . 4 x a,w.zil a '. .ROLLSIIZEx � 1ROLLWEIGHT °°?(APPROX) fi FR-10 10 Squares (1000 sq. ft.) 9.64 Squares (964 sq. ft.) 48.25" x 250' (1225.55 mm x 76.2 m) 96lbs. FR 50 4.2 Squares (420 sq. ft.) 4.02 Squares (402 sq. ft.) 48" x 105' (1219.2 mm x 32 m) 80lbs. stn)ut VIWYtKTles , na PROPERTYa +u '° 'TEST, METHOD' 4Fi 10;. Machine Direction TAPPI T 1009 om-06 37 lbs/in. 64 lbs/in. Cross Machine Direction TAPPI T 1009 om -06 27 lbs/in. 46 lbs/in. SALES Camp Hill, PA (800) 688 -1476 Fax: 1717) 975 -6957 East Moline, IL (800)677 -1476 Fax: (309) 752 -7127 Northglenn, CO (800) 288-1476 Fax: (303) 252-4417 OFFICES Toronto, ONT (888)647 -1476 Fax: (877) 909 -4001 Diboll, TX (800) 766-1476 Fax:(936)829 -5363 Phoenix, AZ (800) 477 -1476 Fax: (480)655 -9209 LaGrange, GA (800) 955-1476 Fax: (706) 882 -4047 1f' CORPORATE SALES & MARKETING 2000 RiverEdge Parkway, Suite 800 Atlanta, GA 30328 GREEN ONE" www.greenzone.com ATLAS Copyright �009,'Atlas, Roofing ivo6iion∎ATL 080450 5/09• ATL-080450-00 FR10 FR50 Da18Sheet V11.i dd 2 5214119 2:5430 PM • 3E T COORD COP0 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -292 DATE: 10/29/10 PROJECT NAME: ANDOVER DISTRIBUTION SITE ADDRESS: 581 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ti,‘012i d'ng Division Public Works ADA NI fr Fire Prevention nStructural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Et Comments: Incomplete ❑ DUE DATE: 11/02/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route ❑ REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditio DUE DATE: 11/30/10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with Lli1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMMERCIAL INDSTRL ROOFING INC UBI No. 600346392 Phone 4254230900 Status Active Address 3601 121St Street Sw License No. COMMEI *205JJ Suite /Apt. License Type Construction Contractor City Lynnwood Effective Date 4/11/1980 State WA Expiration Date 5/16/2011 Zip 98087 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DUGAN, CHRISTINA D President 04/11 /1980 Amount DUGAN, WILLIAM L Vice President 04/11/1980 VCGP018746 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 GREAT AMERICAN 0404872 04/11/2002 Until Cancelled $12,000.00 05/02/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 24 GEMINI INS CO VCGP018746 09/24/2010 09/24/2011 $1,000,000.0009 /17/2010 23 SCOTTSDALE INS CO BCS0022006 05/01/2010 05/01/2011 $1,000,000.0004 /30/2010 22 FORGE INS CO 107848714 107848714 04/01/2007 05/01/2010 $1,000,000.00 04/28/2009 21 TRANSCONTINENTAL INS CO 1078489714 05/01/2006 05/01/2007 $1,000,000.00 04/26/2006 20 TRANSCONTINENTAL INS CO 1078489714 05/01/2005 05/01 /2006 $1,000,000.00 04/29/2005 19 CONTINENTAL CAS 1078489714 05/01/2003 05/01/2005 $2,000,000.00 05/11/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 11/05/2010