Loading...
HomeMy WebLinkAboutPermit D10-297 - CRIBS 2 BUNKS - STORAGE RACKSCRIBS 2 BUNKS 730 ANDOVER PK E EXPIRED 08-17-11 D10-297 City o,I'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2623049095 Address: 730 ANDOVER PK E TIIKW Suite No: Project Name: CRIBS 2 BUNKS DEVELOPMENT PERMIT Permit Number: D 10 -297 Issue Date: 02/18/2011 Permit Expires On: 08/17/2011 Owner: Name: 790 ANDOVER LLC Address: PO BOX 287 , MEDINA WA 98039 Contact Person: Name: DAVID HOLM Address: 932 INDUSTRY DR - SUITE 210 , TUKWILA WA 98188 Contractor: Name: CEDAR RECYCLING INC Address: 411 W VALLEY HWY S , PACIFIC WA 98047 Contractor License No: CEDARRI981CM Phone: 425 - 282 -5065 Phone: (253)804 -0404 Expiration Date: 02/18/2012 DESCRIPTION OF WORK: INSTALLATION OF PALLET RACKING AND REINSTALLATION OF EXISTING RACK INSTALLED INCORRECTLY Value of Construction: $0.00 Fees Collected: $338.40 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0025 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D10 -297 Printed: 02 -18 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature. I hereby certify that I have read an governing this work will be compli N N N • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Public: Non - Profit: N Public: Date: VllA bl ned this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not p construction or the performance of work. to this permit. Signat e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: 2/1g/i1 Print Name: Gd! "d. //e /!/K This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 C10 -297 Printed: 02 -18 -2011 6: All construction shall be done in ith the approved plans and the requirem of the International Building Code or International Residential International Mechanical Code, Washingt• ate Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 11: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 12: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 13: Clearance between ignition sources, such as light fixtures, heaters and flame- producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 20: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mnm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) doc: IBC -7/10 D10 -297 Printed: 02 -18 -2011 21: Aisles leading to required exits shall bevided from all portions of the building and tquired width of the aisles shall be unobstructed. (IFC 1013.4) 22: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D10 -297 Printed: 02 -18 -2011 A CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Building Permit No. . Mechanical Permit No Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 2-6 Z 3 c- 1 09 S Site Address: 730 Andover Park East Suite Number: 100 Floor: New Tenant: ❑ Yes gl ..No Tenant Name: Cribs 2 Bunks 1 C/�f lhof!KS �� Property Owners Name: 790 Andover LLC Mailing Address: Zip City State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: ! - � etp ,' eZ /Yal ' 1 Day Telephone: t/ C Q Z S Mailing Address: wk. 932 .740e,%/ yQ b“f mitt 7 /C TK% . 7� �/� 9 £t&' � , Zip E -Mail Address: k _�_ kt i Z n d- C awi Fax Number: 41z ( ?8Z- City State GENERAL CONTRACTOR INFORMATION — (Contraetor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Cedar Recycling Inc / The Rusty Rack Guy's Mailing Address: 411 West Valley Hwy S Contact Person: Steve Brewer E -Mail Address: seve@rustyrackguys.com Contractor Registration Number: CEDARR1981 CM Pacific City State Day Telephone: (253) 804 -0404 98047 Zip Fax Number: (253) 8042702 Expiration Date: 02/18/2010 ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Rack Design and Engineering Mailing Address: 412 West Broadway, STE 204 Contact Person: Gamik Ohanian E-mail Address: gorack1@yahoo.com H:\Applieations\Fonns- Applications On line\2010 Applications \7 -2010 - Permit Applicatiomdoc Revised: 7-2010 hh Glendale City State Zip Day Telephone: (818) 240 -3810 Fax Number: (818) 240 -3813 91204 Page 1 of 6 BUILDING PERMIT INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 922.82 Existing Building Valuation: $ Scope of Work (please provide detailed information): Installation Of Pallet Racking and reinstallation of existing rack, installed incorrectly. Will there be new rack storage? m Yes ❑.. No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:WppIications\Forms- Applications On Iine12010 Applimtion0-2010- Permit Appiimtioadoc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New 4,A Type of Construction per IBC Type of Occupancy per IBC I' Floor 2°d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:WppIications\Forms- Applications On Iine12010 Applimtion0-2010- Permit Appiimtioadoc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW I ! : UTHORIZED AGENT: Signa Prin Name: /7L V►1 Mailing Address: 33r ?be__ Z / Date Application Accepted: Date: I(// (/ d Day Telephone: q ZS ` Z SZ. (J.4- 78/8M City State Zip Date Application Expires: 4 I/ Staff Initials4 ,j tt: Applicahons\Forms- Applications On Line \2010 Applications \7-2010 - Pernut Applicahoadoo Revised: 7 -2010 bh Page 6 of 6 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2623049095 Address: 730 ANDOVER PK E TUKW Suite No: Applicant: CRIBS 2 BUNKS RECEIPT Permit Number: D10 -297 Status: APPROVED Applied Date: 11/02/2010 Issue Date: Receipt No.: R11 -00314 Payment Amount: $256.50 Initials: JEM Payment Date: 02/18/2011 01:55 PM User ID: 1165 Balance: $0.00 Payee: CM!' INDUSTRIES, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10520 256.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 252.00 640.237.114 4.50 Total: $256.50 doc: Receipt -06 Printed: 02 -18 -2011 . • Th City of Tukwila Department of Community De velo P ment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049095 Address: 730 ANDOVER PK E TUKW Suite No: Applicant: CRIBS 2 BUNKS RECEIPT Permit Number: D10 -297 Status: PENDING Applied Date: 11/02/2010 Issue Date: Receipt No.: R10 -02217 Payment Amount: $81.90 Initials: LAW Payment Date: 11/02/2010 02:29 PM User ID: 1632 Balance: $130.50 Payee: DAVID HOLM TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 025888 ACCOUNT ITEM LIST: Description 81.90 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 81.90 Total: $81.90 doc: Receiot -06 Printed: 11 -02 -2010 BY G. OHANIAN DATE 10 -28 -10 SUBJECT RAdK DENIdN & EN(4INEERINd do. 412 WEOT BROADWAY, BUTTE #204 GLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 1 JOB NO RD -15141 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: CMF INDUSTRIAL /CRIBS 2 BUNKS 730 ANDOVER PARK EAST TUKWILA, WA. 98188 PER IBC 2009 EDITION SECTION 2208 STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 5 DRAWINGS: RD -15141 EXPIRES 12 -26 -11 tO2't7 �.� PILE COpy CODE CpMpL� COMPLIANCE FEB 08 zun City of Tukwila BUILDING DIViRinni RECEIVED NOV 02 2010 PERMIT CENTER BY G. OHANIAN DATE . 10 -28 -10 SUBJECT RAdK DEOI(N & ENOINEERIN( d0. 412 WEB T BROADWAY, BUITE #204 dLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 2 JOB NO.. RD -15141 TYPE "A" BEAM M= 82 =18 "K SR= .54 <1.23 4 A 384.1 L E = •41 "< 180 = .80" x TYPE "B" BEAM M= 82 =14 "K SR= .41<1.48 LOAD PER BEAM + 25% IMPACT LOAD (2KX.88) +(1KX.25) = -2_ = 1.0 K 2 BEAMS Ix =3.22 S„ =1.23 F Y= 55 KSI. LOAD PER BEAM + 25% IMPACT LOAD (2 Kx.88) +(1 K X.25) = = 1.0 K 2 BEAMS IN A_ 5xwL4 =.13 "< L -.60" 384.1,.E 180 - SEISMIC DESIGN _ lux! XI V- Rx1.4 xW Ix =4.34 S„ =1.48 F Y= 55 KSI. IBC 2009 -SEC. 2208, PER RMI SPECS. ASCE 7 -05 (SEC. 15.5.3) SOS =.94 (USGS WEB SITE, "SITE CLASS 0 ") 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED W =D.L.+ 3 PALLET LOAD TYPE "A" LOAD PER COL. = 2x2.0 K =2.0K 2 COL. P= .2 DL+ (2.O K X.75) =1.7K LONGIT. SEISMIC W =.2DL+ (2.OPLx.67) = 1 .5 K V = .17K LONGIT. 0 (0 K \ = 25 TRANS. RA .11 K 06 K Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4494 Longitude = - 122.2507 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x 51 Site Class D - Fa = 1.0 ,Fv = 1.519 Period Sa (sec) (g) 0.2 1.407 (SMs, Site Class D) 1.0 0.730 (SM1, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4494 Longitude = - 122.2507 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SDI = 2/3 x SM1 Site Class D - Fa = 1.0 ,Fv = 1.519 Period So (sec) (g) 0.2 0.938 (SDs, Site Class 0) 1.0 0.487 (SDI, Site Class D) 3 •K .17 K 0 3"k 10'K By G. OHANIAN DATE . 10 -28 -10 SUBJECT RACK DEOI(4N & ENdINEERIN( CO. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 3 JOB NO.. RD -15141 TYPE "B" LOAD PER COL. = 3x2.0 K =3.0K 2 COL. P =.2DL+ (3.0Kx.75) =2.5K W =.20L+ (3.0x.67) = 2.2 K V = .24 K LONGIT. TRANS. •37 K COLUMN ANALYSIS TYPE "A" 17 x Fy =55 KSI Ae =.62 I x =.76 S0=.51 rx =1.1 ry =.61 COMBINED STRESS RATIO Pex= (K�)2 =21 Qc =1.8 f2cP — Qb =1.67 ox =1— .86 Pex Cmx =.85 BASE PLATE TYPE "A" ANCH. TENSION = 0 ANCHOR SHEAR = .17 K LONGIT. SEISMIC o o co .24 K KL 7 =-1-7-1— = 93 x KL_42 — ry — 69 Mn =Se .Fy = 28 f2P.P Ob.Cmx.M =.77<1 n Mn.ax (1) -1/2 "0 SIMPSON STRONG ANCHOR PER BASE PL., 3 1/4" EMB. ESR -1771 SPECIAL INSPECTION IS REQUIRED 6.K 2 Fe= (K�j2 -34 rx 2 Fn =Fy (.658 Ac )= 28 KSI Pn =Fn.Ae = 17K 1.7 K Ac = e e = 1.27 Xc<1.5 10 01 BASE PLATE ' 8„ 01 By' G. OHANIAN DATE . 10 -28 -10 SUBJECT RAdK DEOICiN & ENdINEERIN€4 d0. 412 WET BROADWAY, BUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 4 JOB NO RD -15141 COLUMN ANALYSIS TYPE "B" y 3" t =.07" Fy =55 KSI Ae =.59 I,=.95 Se =.6 rx =1.2 ry =1.1 COMBINED STRESS RATIO Pex= (K�)2 =41 Oc =1.8 flcP Qb =1.67 ax =1— Pex _ — 89 Cmx =.85 BASE PLATE TYPE "B" ANCH. TENSION = 0 ANCHOR SHEAR = .12 K r — 48x1.7 X KL =1 =43 ry 1 1 Mn =Se .Fy =33 Qc.P +11b.Cmx.M =.47<1 Pn Mn.ax (2) -1/2 "0 SIMPSON STRONG ANCHORS PER BASE PL., 3 1/4" EMB. ESR -1771 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.105x1 x65 =3.4 K BEARING CAPACITY OF COL. HOLE 7/16 "0 RIVET A = .1 Fy = 79 KSI Pa = .1x79x.4= 3K Ma = (3Kx4 ") +(1.5Kx2 ") =15 "K 3 PIN CONN. CONN. MEND— .01XWI2= 1.4 "K M = 6.5 "K M— 7.9 "K SEISMIC TOTAL TAB AREA =.14 Fy =62KS1 Va TAB =.14x.4x62 =3.5K .5x.07x1 x65 =2.3 K BEARING CAPACITY OF COL. HOLE H.DUTY WEDGELOCK CONN. Ma = 3.5Kx9 " -21 "K CONN. Fe =(/2 =63 r, 2 Fn =Fy (.658 c )= 38 KsI Pn= Fn .Ae = 22 K 25K 6 "K 8 "x5 "x3/8" BASE PLATE 6.5 "K 3 PIN CONN. TYPE "A" Ac= V'Fy /Fe = .93 Ac<1.5 WEDGELOCK CONN. TYPE "B" BY G. OHANIAN DATE. 10 -28 -10 SUBJECT RAdK DENI(N Sc ENC INEERIN(1 do. 412 WET BROADWAY, SUITE #204 LENDALE, dA. 91204 TE14(818)240 -3810 FAX:(818)240 -3813 SHEET NO 5 JOB NO.. RD -15141 OVERTURNING MOT = COL .37 Kx Cx 160 °X.66 =78 K MR = 2.5 Kx35 "= 87 "K NO UPLIFT LOAD TO DIAGONAL P = .37 Kx2 x 54 = .83 K COL 48 FY =55 Ksl Ae =.26 rx =.48 Q =.74 L= 54" Pa= 2.9K CHECK WELDS P°= (1_.01L)L.t.Fu =3.9K fZ = 2..55 —0-= 1.5Kx2 = 3.0K SIDES CHECK SLAB 2500 — 1.1 °' 2200 V 158 =13" .37K 1.1x144 = 158 M= (2. )2x2200x 2 x12 =573 "# S= 12x5.52 = 60 6 573 = 10 <1.6V'2500 =80 60 25K 2.5K x 1 M 35" .37K 0 TOP LEVEL LOADING 0 W= .2 "11=1.2 K LOAD PER COL. V= .20 K MOT = •20Kx2 x144 " = 57 "K COL MR = 1.2Kx35 "= 42 "K UPLIFT = 57-42 .42 K BOTH SIDES TYP x t =.07" 2500# 5 1/2" CONCRETE SLAB 2800 PSI. CONC. 2200 PSF. SOIL 06 -30 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director DAVID HOLM 932 INDUSTRY DR - SUITE 210 TUKWILA WA 98188 RE: Permit No. D10 -297 730 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/17/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 08/17/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, --ILO —4...._ Bill Rambo Permit Technician File: Permit File No. D10 -297 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 r • Citj (o TU b i Jim Haggerton, Mayor epartr i ; era of Community Development Jack Pace, Director November 10, 2010 David Holm 932 Industry Dr — Suite 210 Tukwila, WA 98188 RE: Correction Letter #1 Development Permit Application Number D10 -297 Cribs 2 Bunks — 730 Andover Pk E Dear Mr. Holm, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Re6,„L Bill Rambo Permit Technician encl File No. D10 -297 W:\Permit Center \Correction Letters\2010\D10 -297 Correction Letter #I.DOC 6300 Southcenter Boulevard, Suite #100 o Tukwila, Washington 98188 o Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: November 10, 2010 Project Name: Cribs 2 Bunks Permit #: D10 -297 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plan shows only one egress door. Rollup doors do not qualify as means of egress door. For a sprinkled building the travel distance exceeds 100 feet from the most remote point according to this plan; 75 feet for non - sprinkled. If there are other egress doors, please show those doors. Otherwise an additional egress door will be required where the common path of egress travel will not exceed 100 feet. (IBC 1014.3) 2. Specify the building construction type and indicate if this building is a sprinkled building. Typically most of these buildings have an office area. Please clarify and show the office area if applicable. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PERMIT PLAN REVIEW /R TING SLIP ACTIVITY NUMBER: D10 -297 PROJECT NAME: CRIBS 2 BUNKS SITE ADDRESS: 730 ANDOVER PK E Original Plan Submittal X Response to Correction Letter # 1 DATE: 02 -01 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 11 i ding Division Public Works ❑ Fire Prevention Structural Planning Division n ❑ Permit Coordinator 91 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02-03-11 Complete Incomplete n Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved 111 Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 03 -03 -11 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 It2E tf • / 4ry PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -297 PROJECT NAME: CRIBS 2 BUNKS SITE ADDRESS: 730 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # DATE: 11 -02 -10 Response to Incomplete Letter # Revision # After Permit Issued DEPARTME TS: dtldin lsion Public Works ,4A qwc, a Fire Prevention Fire Prevention Structural ❑ Planning Division Permit Coordinator El DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -04-10 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -02 -10 Approved Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: \ -10— 0 Bldg IR Fire ❑ Ping ❑ PW ❑ Staff Initials: ( Documents/routing slip.doc 2 -28 -02 • 1 City of Tukwila Department of Community Development 6300 Southccntcr Boulevard, Suite 1(10 Tukwila. Washini.ton 98188 Phone: 306 - 431 -3670 Fax: 206-431-3665 Web site. http. //www.ci.ltrktrila.wa.tee Steven Al Ahrllel, Alarm. Sieve hancasier, Director REVISION SUBMITTAL Revision submittals roast be submitted in person at the Permit Center. Revisions will not he accepted through the moil, fax, etc. Date: 1 ❑ Response to Incomplete Lcttcr 1! ® Response to Correction Lcttcr / _ 1 flan Check /Permit Number: D 1 0-297 ❑ Revision # _ _ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Cribs 2 Bunks Project Address: 730 Andover Pk E Contact Person: awe— Phone Number: Zo — 730 - S'ZCo Z Summary °of Revision: RECEIVED CITV OF TU _F_EBA 1 BM Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 2.- 1 "C 1 . lapplication:Olorm;- application. un Im rrt loon uhmn!ai Created: 8 -13- 21)04 Revised. rin ti 4 6 U 0 EGRESS 1 d 102' REVIEWED FOR CODE COMPLIANCE AP DnUED FEB082011 Ccif of BUILDING : VISION STRUDI -BELT PALLET RACKING LIGHTED EGRESS PATH J A t7 1 I/7Z r' A 48" X 144' A 98' -3" 48" X 144" 48" X 144 " IA 48" X 144" A 48" X 144' 15'-3" 135' REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1' 7°7 ;C-"1 :—, i7r' „' :' i ' 17 ,.-' ' -' ,1-'1- ' 1P ---1 _ ia'ji Lf iiED FOR: : echanicai Eiectricai Piurnbing . GQS Pipin LEGEND - CITY APPROVEb EGRESS LIGH'T'ING FILE COPY Permit No., —2 °1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged B Date: � 2-g-4( City Of Tukwila BUILDING DIVISION CORRECTION b\O---197 RECEIVED FEB 0 1 2011 PERMIT CENTER 1 t* 1:110 ;411.44. WW1; N `v 1-7\' L. P N tO ?E o0 as u O p.i o • r+ v . Lai Cre GC).. CO CO DRAWN BY JAL SCALE: 1/8” -1 a 0" DATE: 9/26/2010 DRAWING NO: CHECKED 8T SHEET NO. 1 OF SHEETS 1/8' 130TH SIDES TYP. BRACING COr`NECTION DETAIL FOR RACK TYPE "N' .375R (o oocS`o 2" TYP. AS NOTED 3" --1/8" 7/8" 1 5/8" f --3/4" 1 1/2 "( .075 THK 1111/4" SECT. A-A FOR RACK TYPE "A" LM2O 14GA ASTM A570 GR50 FOR RACK TYPE "A" imam SINGLE embus SECT. B -B FOR RACK TYPE "A" R1/8" TYP, 5/8" DIA. 2 HOLES 3/8" THK. AS NOTED • - 8' BASE PLATE DETAIL (2) -1/2 "0 ANCHOR BOLTS PER. BASE PLATE 3 -1/4" EMB., (SEE NOTE NO. 4) FOR RACK TYPE "B" 6" 1" 12' i "0 SAFETY LOCK (1000# CAPACITY) 176-1°0 RIVET ASTM A576 -90B HOT - WROUGHT UNS G10100 GRACE C -1010 LBC50 FOR RACK TYPE "A" II RACK TYPE "A" 5" BEAM FACE INTERLAKE PALLET RACKING MIM 3/8" THK OR 1OGA 5/8" DIA. 2 HOLES 8" --EH H1 /2" FLOOR ANCHOR DETAIL "§EE NOTES FOR SPECS FOR RACK TYPE "A" & "B" BASE PLATE DETAIL FOR RACK TYPE "A" 5 1/2" BEAM FOR RACK TYPE "B" RACK DETAILS SCALE: 4" = 1" RACK TYPE "B" 52" BEAM FACE STUDI -BILT PALLET RACKING RACK ELEVATIONS SCALE: 1 - P-0" z STRUCTURAL NOTES: 1. DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2009 EDITION, SECTION 2208. 2. STEEL FOR ALL SHAPES FY= 55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED). 3. NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SRO OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES). 4. ALL ANCHORS SIMPSON STRONG BOLT WEDGE TYPE (ESR.1771) SPECIAL INSPECTION IS REQUIRED. 5. CONCRETE SLAB 51" THICK 2,800 PSI, SOIL BEARING CAPACITY 21200 PSF. 6. STORAGE RACK CAPACITY 2,000 #/ LEVEL. 7. RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (2,000 #/ LEVEL). 8. STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF i" IN 10' -0" OF HEIGHT. 9. THE CLEAR. SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP 0 THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. FIRE PROTECTION NOTES: 1. SPRINKLER DENSITY IS .325GPM OVER 2,500SQ FT. 2. SPRINKLER HEAD TEMPERATURE IS SET AT 265 °F. 3. STEEL PARTS AND WOODEN FURNITURE STORED IN CARDBOARD BOXES, NON- ENCAPSULATED. 4. TOP OF STORED PRODUCT NOT TO EXCEED 20' -0''. 5. APPROXIMATE CEILING HEIGHT 23' -9". EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. REVIEWED FOR CODE COMPLIANCE fi. (d City of Tukwila BUILDING nivi,S;nN Dto) 4297 RECEIVED NOV 02 2010 PERMIT CENTER m S4 .- 2 1 � W c4.5&r;'4) , i141 vity_ c J 1 00 00 00 rn <t w ° DRAWN BY :: JAL SCADS: AS SHOWN DATl4`: 9/26/2010 DRAWING No: CICJOD BYE saw 2 o S ETS