Loading...
HomeMy WebLinkAboutPermit D10-344 - PETITT RESIDENCE - IMPROVEMENTPET!JFI1 RESIDENCE 3938 S 113 ST D1O -344 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3351400260 Address: 3938 S 113 ST TUKW Suite No: Project Name: PETITT RESIDENCE DEVELOPMENT PERMIT Permit Number: D 10 -344 Issue Date: 03/01/2011 Permit Expires On: 08/28/2011 Owner: Name: AVILA - PETITT KALIMAR A +DYLA Address: 3938 S 113TH ST , TUKWILA WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Phone: 206 296 -7437 Phone: 480 - 921 -4079 Expiration Date: 12/31/2011 DESCRIPTION OF WORK: SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE INCLUDING: SOUND INSULATION WORK; VENTILATION WORK AND UPGRADE; AND MISCELLANEOUS WORK TO WINDOWS, DOORS INSULATION, AND ABATEMENT. Value of Construction: $31,964.00 Fees Collected: $1,141.27 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0022 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D10-344 Printed: 03 -01 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: J1- Date: 3 E I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ance of vyork. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: L Date: 3- 11 Print Name: C4441_511 &I A A(z_c- r+vi.ErA This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila doc: IBC -7/10 D10 -344 Printed: 03 -01 -2011 Building Department (206- 431 - 3670). • 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D10 -344 Printed: 03 -01 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: %iwww.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. PlumbinglGas Per Public Wo (For e only Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3938 S. 113th St. Tenant Name: Dylan Petitt and Kalimar A. Avila - Petitt Property Owners Name: Dylan Petitt and Kalimar A. Avila - Petitt Mailing Address: 3938 S. 113th St. King Co Assessor's Tax No.: 3351400260 Suite Number: Floor: New Tenant: ❑ Yes ®..No Tukwila WA 98168 City State Zip CONTACT PERSON - who towe contact when yourpe issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD Alt plans must be wet stamped b Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Zip Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 ENGINEER OF RECORD - I plans must be wet stamped by :Engineer of Reci Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application. doc Revised, 1 -2009 bh Page 1 of 6 BUILDING - PERMIT INFORMATION' -- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 1 64, Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. ovid AI Building Areas in Square Footage to st Floor 1,150 Addition to' Existing Structure' Type of Construction per IBC VB Type of Occupancy per IBC R3 2nd Floor 3r4 Ft Floors sement Aceessor e* Attached Garage ched Gai ge Attached Carpo Detached Cat Covered Deck Uncovered De k PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 11 \Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc Revised. 1 -2009 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR . ' IZED AGENT: Signature: .if, Print Name: ody Leung Timothy Fenlason Day Telephone: (206) 624 -2777 Date: e . 10 Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: ri_ i n 1, to Date Application Expires: tte 1 it [ t 1 Staff Initials: H \Applications \Forms - Applications On Line \2009 Applications\ I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 �J�`N1LA wqs City of Tukwila o `�2 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3351400260 Address: 3938 S 113 ST TUKW Suite No: Applicant: PETITT RESIDENCE RECEIPT • Permit Number: 1)10 -344 Status: APPROVED Applied Date: 12/17/2010 Issue Date: Receipt No.: R11 -00283 Payment Amount: $693.45 Initials: TLS Payment Date: 02/15/2011 08:15 AM User ID: 1670 Balance: $0.00 Payee: PAMELA K KUEHL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 030659 ACCOUNT ITEM LIST: Description 693.45 Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 688.95 640.237.114 4.50 Total: $693.45 doc: Receipt -06 Printed: 02 -15 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3351400260 Address: 3938 S 113 ST TUKW Suite No: Applicant: PETITT RESIDENCE RECEIPT Permit Number: D10-344 Status: PENDING Applied Date: 12/17/2010 Issue Date: Receipt No.: R10 -02526 Initials: User ID: JEM 1165 Payment Amount: $447.82 Payment Date: 12/17/2010 10:50 AM Balance: $693.45 Payee: KING COUNTY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 669601 447.82 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - RES 000.345.830 447.82 Total: $447.82 doc: Receiot -06 Printed: 12 -17 -2010 INSPECTION RECORD Retain a copy with permit I SP CT ON NO. PERMIT NO. • 'CITY OF TUKWILA BUILDING DIVISION O 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 ,(o'3 -11 Projgt-: t '1rTr f. Type of Inspection: ftAJit L $L; 1 J,�(.) Address: - 3g3k 113 Z.• S Date all d: l c.pn _ i �." et., Special Instructions: �7/� E--- CSA • Date Wanted: . � ,-,/, ,-,/, a.m. ,P.17 Requester: Phone No: 5' 5 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: ,P% M `i /.a hl (P1-,0 0K. ( A.1./k/ .A7 Me Ai. Inspegfor: Date' r.„14 REINSPECTION FEE REQUIRED. Prior to next inspection..fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. P, fe-11.27---7772-W ' '177--F" -T.'17.77.717.4"; INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IA • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Ot o - 344 Prcct: . ljf"--rrrr. PscS Type-of Inspection: - go JO( -IA/ itit el CA Address: 3 3 &' --Cs. II 3 ST Date Called: Special Instructions: Date Wanted: 7 ,.. 2,49 .4( ...757_,Ta.rni.. Requester: Phone No: 0 c - E-'14. - oel ( 0 IKZpproved per applicable codes. OCorrections required prior to approval. 1- j COMMENTS: fsp 11 RE Date: 2. I SPECTION FEE EQUIRED. Prio to next inspection, fee must be d at 6300 Southcenter Blvd., Suite 00. Call to schedule reinspection. 4 r. 4 1 06 -30 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D10 -344 3938 S 113 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/28/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 08/28/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, -1,..z0 '4,..- Bill Rambo Permit Technician File: Permit File No. D10 -344 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PPERMT COORD C6Pil PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -344 DATE: 12/17/10 PROJECT NAME: PETITT RESIDENCE SITE ADDRESS: 3938 S 113 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART E CTS: \ k1 Building Division 1 Plevoit'sVc ire Prevention Structural n NA19421tZ Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 14 Comments: 77 Incomplete DUE DATE: 12/21/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01/18/11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Prjpter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type G & G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation Parent Company G & G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2011 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 FIRE INS CO 59BSBEA9058 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03 /2011 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 CEOXINGTON INS 4392611702 12/31/2010 12/31/2011 $1,000,000.0001 /11/2011 1 CEOXINGTON INS 4392611701 12/31/2008 12/31/2010 $1,000,000.00 01/14/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 03/01/2011 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00570C10 BID PACKAGE M -15 5- 53- 0058 -040 SEPARATE PERMIT REQUIRED FOR: Er Mechanical u tlectricat IrPIumbing 3/Gas Piping City of Tukwila E 1_rli.1:”NG DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FI Permit No. E COPY Pi €n review approval is subject to errors and omissions. 4pproval of construction documents does not authorize t ; . Violation of any adopted code or ordinance. Receipt 01 approved Field Cop ,and s is ac kriowled9ed By Date: Q.1: - / O - ?-o/ l 3-- City Of lbkwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Developement City of Seattle, WA APPLICABLE CODES: 2006 Seattle Residential Code, international Fire Code, International Mechanical Code 335140 -0260 LEGAL DESCRIPTION: HILLMANS C D MEADOW GARDENS "3 ZONING: 5F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Change) V B NON SPRINKLERED No permitted information is available. BUILDING AREA: No change to building footprint. Addition:. 0 s.f. Remodel: 0 s.f. Sound Insulation: 0 s.f. DRAWING INDEX TO.0 TITLE SHEET, PROJECT INFO. A1.0 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHEDULE 4 DETAILS 42.1 DOOR TYPES, SCHEDULE 4 DETAILS 422 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS E1.0 ELECTRICAL PLAN PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 296. 0190 Contact: Sharyn Parker E- mail: Sharyn.Parkerekingcounty.gov ARCHITECT: 511. Stemper Architects P.L.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206. 624. 2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerresmstemper.com melodymsmstemper.com timesmstemper.com ACOUSTICAL ENGINEER: 55A Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206. 839. 0824 Contact: Mohamed Alt Allaoua E -mail: mohamedessaacoustics.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206. 318. 0641 Contact: Derek Orkney E -mail: derekoegreenbusch.com ELECTRICAL ENGINEER: Tres West Engineers 2102 5. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253. 412. 3463 Contact: Brent Rollins E -mail: bcratreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206. 162. 4180 Contact: Tim Ogden E -mail: tim ogdenspbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. "200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwelleJonespayne.com REVIEWED FOR CODE COMPLIANCE APPROVED JAN 06 2011 City D ON RECEIVF, CINOFTUic LA DEC 17 2010 PERMIT CENTER VICINITY MAP (NTS) 3938 S 113TH ST TUKWILLA, WA 98168 DI o•-• S.M.STEMPER ARCHITECTS A Professional Limited LIabitity Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 RECl 11=1 f::D sjnrE OF 111 'vrf� . Ncr 12/6/10 3938 S 113TH ST 0 0 2 W Q z W O z 1- g z v 0 < 0 z W 0 uJ I.J.. MPROVEMENTS AIP NUMBER 5 -53- 0058 -040 SEATTLE WASHINGTON DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1217 NEW 24" x 24" ATTIC ACCE 42.2 IN NORTH NOTE: 1 LEAD PAINT AND 02081, RESENT AT TH15' SIDENCE. REFER,to SECTION CONTRACTOR TO PROTECT 0 2. CONTRACTOR TO TEMPORARILY ORIGINAL LOCATIONS. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALE ALVAGE. PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 0 FU- NITURE AN MOVE FURNITUF I. OS SESSIONS FROM DAM. E AND DUST. ONTENTS, WALL HANGINGS AND FIXTURE NOTE: EXTERIOR TR UIRED AND RETURN THEM TO THEIR TO 5:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE ANC) ROOMS IN THE RESIDENCE FOR WEEKENDS. OORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 1S ON SITE REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME' DAY BETWEEN S :00` AM AND S:00 FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. ALL WORK AREAS SHALL BE BROOM-CLEANED AT THE END OF EACH WORK DAY. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY REF: ELECTRICAL AND MECHANICAL WHERE SOFFITS A N D /OR MEC H.' COMPONENTS INTERFERE WITH (E) CLOSET SHELVING , DEMO (E) SHEL V ING AS REQ D AN D RE CON STR RU CT A (E) CONFIGURATION ITH TS AN /O MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TOM MATCH rE , SHELVING IN COORDINATION W SOFFITS AND/OR E L MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE. RECONSTRUCT SHELVING 60 AS NOT TO INTERFERE; WITH THE OPERATION OF fiECHANIC41. UNIT ACCESS HATCHES. ENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. HERE CEILING FINISHES ARE DISTURBED BY THE WOK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVEF DES OF TEXTURE AND DENSITY I OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE 'PROJECT Al (N. REEL4CEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COATS ALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPE TED SM DETECTORS. SEE ELECTRICAL SHEET El.c FOR LOCATIONS AND DETAILS OF INTERCONNCTED SMOKE DETECTORS. TALL SAFETY GLAING PER CODE. SEE WINDOW TYPE SCHEDULE. AXIMUM POWER MT IS EIGHT a' PO R T BE "'•VIDED AT SIDENCE BE FO S: A.M. EMOLISH' ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WO REFER TO ELECTRICAL FOR TIMER LOCATION RONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUI ENT. JURISDICTIONAL CLEARANCE: 3'" CLEAR N FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT - CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICA_. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. EXISTING WINDOW "COVERINGS MUST BE REINSTALLED ON THE SAME DAY' AS COMPLETION OF WINDOW INSTALL. IF UJINDCUJ COVERINGS` ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST E PROVIDED.` PLAN KEYNOTES DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW HEDULE ON SHEET A2.0 DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 42.1 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH MECHANICAL. INSTALL NEW THERMOSTAT COORDINATE WITH MECHANICAL INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER INSTALL FIREPLACE CAP AT (E) CHHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. INSTALL ROOF MOUNTED BAFFLE' TO (E) KITCHEN EXHAUST REF. 2/422 FOR DETAIL CAREFULLY CUT INTO (E) CEILING TO INVESTIGATE` EXISTING ATTIC CONDITION. INSTALL NEW ATTIC ACCES PANEL, REF. 4/42.2 FOR DETAIL, COORDINATE (SOFFIT WITH EXISTING MILLWORK. ACCESS TO SITE AND PARKING THE CONTRACTOR AN THEIR SU ONT CTORS SHALL NOT PA OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. S.M.STEMPER ARCHITECTS A Professional. Limited Liability Ca 4000 DFLRIDGEWAY SUITE 200 • SEATTLE, WA (200)'624-°2777 • FAX (206) 624 12 /(c' /10 z 0 Z Z 0 Z 0 z z z EAST E AIP NUMBER 53- 0058 -040 LEGEND ACOUSTICAL WINDOW NOT USE NOT USED DATE 12/6/10 ? ` ISSUED BID PACKAGE 'M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER &TF EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.0 OW SCHEDULE ENDOW TYP FLOOR / CEILING GRILL NOT USED ELECTRICAL PANE ATHER TEXTURED CEILING OVER AT A IN. OF 24" FROM EDGE OF PATCHING. ATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL ILINC DEMOLITION FOR ATTIC PANEL AND WHOLE HOUSE VENT INSTALLATION. REF, MECH. 4 ELECT. F. GENERAL NOTE 11 OR FRESH AIR INTAKE GRILLE FOR UNIT. VENT BAFFLE ATTIC IN ULATION FLOOR PLANS NOTES BATTERY OP DETECTORS cosavi DEC KITCHEN EXHAUST VENT BAFFLE ETER A1.0 0810.03.1217 WINDOW TYPES SLIDER 2 FIXED OVER CASEMENT 3 FIXED OVER FIXED 4 FIXED WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A DINING ROOM 1 3' -10" x 2' -4" PAINT/PAINT - 1/A2.0 B LIVING ROOM 1 3' -10" x 2' -4" PAINT/PAINT I/A2.0 C LIVING ROOM 2 2' -2" x 4' -11" PAINT/PAINT 2/42.0 D LIVING ROOM 3 3' -11" x 4' -11" PAINT /PAINT 2/42.0 E LIVING ROOM 2 2' -2" x 4' -11" PAINT/PAINT 2/42.0 F KITCHEN 4 I' -9" x11-9" PAINT/PAINT 2/42.0 G KITCHEN 1 3' -10" x 3' -4" PAINT/PAINT 1/A2.0 H BEDROOM 1 I 3' -10" x 2' -4" PAINT/PAINT I /42.0 I BEDROOM I I 4' -11" x 2' -9" PAINT/PAINT 1/42.0 J BEDROOM 2 1 4' -11" x 2' -11" PAINT/PAINT I/42.0 K BEDROOM 3 I 3' -11" x 2' -9" PAINT/PAINT I/42.0 (E) = EXISTING WINDOW TYPE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING UIINDOUJ OPENING DIMENSIONS. (E) UJD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) UOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN TIE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) WALL UNDERLAYMENT (E)Y" EXT. SHEATHING SELF ADHERING MEMBRANE HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM UJD. JAMB LINING ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E)1/2" EXT. SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN WINDOW HEAD WINDOW JAMB l�f TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE U/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXT. SHEATHING (E) UJD SIDING 1 f WINDOW SILL (E) GLIB HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IUD JAMB LINING SEALANT BACKER ROD 4 SEALANT 3/4" W. SILL - STAIN TO MATCH (E) HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GUB WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) T -III SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) T -111 SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE UINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -1II SIDING (E) WALL UNDERLAYMENT (E) I/2" EXT. SHEATHING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY WINDOW HEAD ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAIL FLANGE TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) T -111 SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) I/2" EXT. SHEATHING [71 WINDOW JAMB (E) GLOB (E) WALL UNDERLAYMENT (E)Y" EXT. SHEATHING SELF ADHERING MEMBRANE IARDUOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM UJD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD (E) GLIB WD JAMB LINING SEALANT /8" • let WINDOW SILL BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GWB 2 T_111 SIDING - WINDOW DETAIL SET 3 =1 -0 bo34y REVIEWED FOR CODECOMPLIANDE Aponnven JAN Os 2011 City of Tukwila BUILDING DIVISION RECEIV CITY OF TU LA in 172010 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, IYA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED / £HITECT SCOTT !jTE!MPER STATE OF ASHINGTON I2/6/10 3938 S 113TH ST I-- O 0 J z 0 I--- Q z w z 1-- z 0 0 z MPROVEMENTS 0 Cw w w 0 z LL 0 J z w 0 w AIP NUMBER 5 -53- 0058 -040 DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1217 DOOR TYPES 1.61 Bo 0 ;j ,4 FLUSH SCW HALF -LITE W/ 4 PANELS W/ SAFETY GLAZING FLUSH SCW W/ SIX PANELS W/ OBSERVATION PORT G EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 ENTRY 1 B 2' -10" x 6' -8" PAINT/PAINT HW -I / 116 DK -2 LOCK -1 1/42.1 2 ENTRY 2 A 3' -0" x 6' -1" PAINT /PAINT HW -1 / 116 DK -2 LOCK -1 2/A2.1 3 ENTRY 1 C 2' -10" x 6' -8" 4 ENTRY 2 C 3' -0" x 6' -1" REMOVE (E) T -111 SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY CUT BACK (E) T -1II SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) T -1I1 SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. 1 DOOR HEAD ■ SELF ADHERING MEMBRANE (E)Y" EXT. SHEATHING 2" MIN. DOOR JAMB AUTOMATIC DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER STRIPPING DOOR PER SCHEDULE (E)Y" EXT. SHEATHING EXISTING FRAMING HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM FILL CAVITY W/ BATT INSULATION DOOR PER SCHEDULE (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING (E) BALCONY FLOOR 4 DECK DOOR SILL T -111 SIDING - DOOR DETAIL SET 3 " =1' -0" DOOR TYPE NOTES 1. NOTE: WHERE SAFETY GLAZING 15 INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. REVIEWED FOR CODE COMPLIANCE APPRIWED JAN 0 6 2011 City of Tukwila BUILDING DIVISION cm�ERIVIu+ DEC 17 2010 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A CHITEGT 'COTT t TEMPE STATE OF IvASHINGTON 3938 S 113TH ST 12/6 /10 O 0 J z z w z z 0 U 0 z AIP NUMBER MPROVEMENTS 0 ww w w 0 z 0 J z w 0 w 5 -53- 0058 -040 z 0 0 z_ Cn I— I— Q DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1217 EXISTING CEILING STRUCTURE (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF ELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE U/ NEW SIDING, ACCESSORIES, * BLOCKING TO MATCH (E). PRE — PRIMED, GALV SHEET METAL UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.— PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. ET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E)Y" EXT. SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" FINISH TO MATCH (E) PAINT AND TEXTURE L J SOFFIT DETAIL ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING TO LEDGER DUCTS PER PLAN WITHIN SOFFIT RE: MECHANICAL 2x2 CONT. NAILER %8" GUB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE U/ ADJ ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS UITH MECHANICAL (E) UD FRAME UJALL ASSEMBLY 1 1/2" = 1' - 0" tO34Lf EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS 1' -2 5/5" DAMPER ROD DAMPER FLAP PREMANUFACTURED ROOF BAFFLE (GROAN— MODEL 634) — BIRD SCREEN SCREW 7461' 4" DAMPER PLATE 1' -6 3/4° SEALENT STRIP SECTION PREMANUFAGTURED ROOF BAFFLE (GROAN- MODEL 634)/ EXISTTIG DUCTWORK SEAL ALL NAILS WITH ROOF CEMENT y5EAL SHINGLES TO ROOF GAP ON TOP AND SIDES NOTE: I. PREMANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURE'S INSTRUCTIONS. KITCHEN EXHAUST BAFFLE 3" = 1' - 0" PIVOT HINGE CAULKING ADHESIVE INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS 6 24" O.C. EXTEND BLOCKING TO ( E) CEILING JOISTS (TYP) (E) GWB SNAP FRICTION CATCH REMOVABLE DOOR PAINT DOOR AND FRAME TO MATCH (E) COLOR OF CEILING ATTIC HATCH & PANEL DETAIL 3 " =1' -0" jn5 ✓lNr's e., ,. it/ __6Jr, 4yzCC ( 2t- � {a mvfS �W � ✓q A cf;),-, 6 /etc --REVIEWED FOR' CODE COMPLIANCE JAN 06 2011 City of Tukwila BUILDING DIVISION INSULATION DAM DETAIL 3 " =1' -0" INSULATION ROOF DAM (E) WALL FRAMING RECEIV CITY OF TU WILA Utz • 17 2010 PERMIT CENTER i S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 4220 REGISTERED ARCHITECT SCOTT !WTEMPE� STATE OF I.. ASHI dGTON 3938 S 113TH ST 12 /6 /IO O 0 J z 0 F- it( z w z 1- z 0 U 0 z AIP NUMBER MPROVEMENTS 0 cnw w w 0 z LL 0 J z w 0 w 5 -53- 0058 -040 DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH MISC. DETAILS A2.2 0810.03.1217 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D • (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING ` \ HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING I -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND R.O. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING II" MIN TYP. I/ MEMBRANE FLASHING AT SILL 5a BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. WINDOW NAIL FLANGE:~ EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. o o 0 0 O 0 0 0 0 0 0 0 0 ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES 4 WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOUJN FOR CLARITY. LAY (E) BLDG PAPER BACK DOUIN OVER FLANGE FLASHING AT JAMBS (8 MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r 1 WHERE REQUIRED, TRIM (E) BLDG RAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRI (FOLLOWIN STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER (21 NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT 5HOU,N FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 11/2" TYP. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL 51—IEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 0 0 0 0 0 0 0 0 3 TYP: Ci INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. �� MEMBRANE FLASHING AT SILL } SCALE: NTS INSTALL SHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. ALLOW I/8" CLEARANCE BETWEEN FLASHING AND BOT. EDGE OF (E) —� -1 SIDING. TRIMMED EDGE OF (E) BLDG PAPER 9� HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING A5 SHOWN. EXTEND I -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) (3\\ MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 1 0 0 0 — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS (,in WOOD TRIM INSTALLATION SCALE: NTS GENERAL NOTES: 1: MEMBRANE FLASHING 15 SPECIFIED IN 0121145 "SELF APHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1-1,45 BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. 0 0 0 J J E7) WINDOW FLASHING INSTALLATION SCALE: NTS bIo.3'14 REVIEWED FOi CODE COMPLIANCE APDQfVED JAN 0 6 2011 City of Tukwila BUILDING DIVISION RECEIV C)TVOFTI� LA DEC 17 2010 PERMIT CENTEF S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 3938 S 113TH ST I2/6/10 O 0 J z 0 z w z E- z 0 U z AIP NUMBER MPROVEMENTS 0 Cw w w 0) 0 z I- LL U J z w 0 w 5 -53- 0058 -040 z 0 CD LU z J I- E- Q Lil Cn DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1217 1/ (,in WOOD TRIM INSTALLATION SCALE: NTS GENERAL NOTES: 1: MEMBRANE FLASHING 15 SPECIFIED IN 0121145 "SELF APHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW 1-1,45 BEEN SET IN PLACE, 51-1IMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. 0 0 0 J J E7) WINDOW FLASHING INSTALLATION SCALE: NTS bIo.3'14 REVIEWED FOi CODE COMPLIANCE APDQfVED JAN 0 6 2011 City of Tukwila BUILDING DIVISION RECEIV C)TVOFTI� LA DEC 17 2010 PERMIT CENTEF S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 3938 S 113TH ST I2/6/10 O 0 J z 0 z w z E- z 0 U z AIP NUMBER MPROVEMENTS 0 Cw w w 0) 0 z I- LL U J z w 0 w 5 -53- 0058 -040 z 0 CD LU z J I- E- Q Lil Cn DATE 12/6/10 ISSUED BID PACKAGE M -15 PERMIT SET PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1217 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP H VAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TD H TOD TP D TSP TYP V VD VTR W WB W/ WG WSVIAQ ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR XX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. } SYMBOL SG -X XXX ABBR S } -+ICE >CI 0 101 EQUIP IDS _ OR OP NG • 0 r,t(i 1 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD RA /EA RG SA SA RA /EA SD VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS PROVIDED UNDER DIVISION FURNISHED /MOUNTED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 383 <.08 "WG 8/4 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 85 383 <.08 "WG 8/4 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL 2006 WSVIAQ DUCT LOCATION 1 MIN VALUE NOTES RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1217 1307 3 75 -113 CFM 85 CFM R -5 1 1. VENTILATION PROVIDED PER THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, TABLE 3 -2 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. MINIMUM INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE LIMITED REGULATED MATERIALS REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SPECIFICATION SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SPECIFICATIONS SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. RECEIVE, CITY OF TUKKWVIL '.ate 17 2010 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APDRf111ED JAN 0 6 2011 City ofTukwila BUILDING DIVISION EXPIRES: 9/08/2010 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 9B106 (208) 824 -2777 • FAX (206) 824 -2973 THE GREENBUSCH GROUP, INC 41111110111910010) ACOUSTICAL AUDIO / VIDEO & MECHANICAL ENGINEERING 1900 WEST NICKERSON STREET SUITE 201 SEATTLE. WA 98119 (206) 378 -0389 (208) 378 -0841 FAX 0810.03.1217 0 0 J z 0 z w 1-- z F- z 0 U z MPROVEMENTS 0 w 2 w w 0 z L U J I—' z w 0 W AIP NUMBER 5 -53- 0058 -040 z 0 0 z Cn DATE 7/1/10 ISSUED BID PACKAGE M -15 100% CD PROJECT ENGINEER CA PROJECT MANAGER DO DRAWN CA, DO & MM LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1217 SEE x (E)SG BEDROOM 1 (E)EF BATH 1 KITCHEN CEILING (E)SG BEDROOM 2 x (E) SG 6 "o4 1- I L 0 N 1 J CLO5ET DINING ROOM LIVING ROOM (E)SG (E)SG (E)SG x MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = FLOOR (E)RETURN FURNACE OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN MOD, INTERLOCK TO FURNACE POC CLOSET WALL, TYP BOTTOM SUPPLY OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE BEDROOM 3 4." NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN NOTES: CAULK FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3 WALL CAP CONNECTION DETAIL SCALE: NONE DRAWING NOTES: 1. RESIDENCE WILL BE FULL CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE, CHAPTER 3 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY — CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WSVIAQ 303.4.2.2. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM INSULATION SCHEDULE ON M1.0. ROUTE DUCT IN SOFFIT TIGHT TO CEILING. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WSVIAQ. bto-•14 p� PARATE APP M1TAND REQUIRED ifiFTIE�Y crIYOI L.A DEC PERMIT t.•N i't:04 EXPIRES: 9/08/2010 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 824 -2973 THE GREENBUSCH GROUP, INC ACOUSTICAL. AUDIO / VIDEO & MECHANICAL ENGINEERING 1900 WEST MCIORSON STREET SUITE 201 SEATTLE. WA 98119 (206) 378 -0369 (206) 378 -0641 FAX 0810.03.1217 0 0 J z O z w z z 0 U C9 z MPROVEMENTS 0 w w w 0 z LL U C (1) J z w 0 w AIP NUMBER 5 -53- 0058 -040 z 0 0 z Cn w I-- I- CO LLI DATE 7/1/10 ISSUED BID PACKAGE M -15 100% CD PROJECT ENGINEER CA PROJECT MANAGER DO DRAWN CA, DO & MM MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1217 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE MOTOR RATED TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O2 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 3O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SCHEMATIC DIAGRAM. L L L N N > 0 N N TIMER SWITCH SET FOR 8HR PER DAY. SEE MECH. HI- 120V I I 1 I -1 30/1 RELY 120V 30/1 IS. 24V RELAY 30/1 1- OUTSIDE AIR DAMPER SEE MECH MANUAL STARTER SWITCH J RELAYS1 rrY124V -I 1— � I 1 J PROGRAMMABLE T -STAT, SEE MECH SUMMER MODE SCHEMATIC DIAGRAM NOT TO SCALE NOTE: THE SCHEMATIC DIAGRAM ABOVE IS BASED ON A GENERIC CONTROL SCHEMATIC AND IS NOT INTENDED TO REPRESENT EXACT CONDITIONS OR SPECIFIC REQUIREMENTS. CONTRACTOR TO ALLOW IN BID, COSTS TO STUDY EXISTING FURNACE AND DEVELOP THE INTERLOCK CONTROL REQUIRED FOR SUMMER MODE OPERATION SIMILAR TO THE CONTROL DEPICTED ABOVE. 1 SUPPLY ( FAN >� SEPARATE FROM HEAT 1 < > HEAT <> I 1 J ELECTRICAL_ LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION G IJGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNEC11ON SCHEDULES FOR SPECIFIC REQUIREMENTS. ® BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 111111 4 DAMPER CONNEC11ON D NON -FUSED DISCONNECT SWITCH o MAST, WEA1HERHEAD Qs' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ®D SMOKE DETECTOR ELECTRICAL METER I TIMER OPERATED SWITCH ,,- I-1 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. CT THERMOSTAT — - — BEDROOM 1 BATH 1 KITCI -TEN QIN NORTH BEDROOM 2 TO FURNACE POWER SUPPLY CLOSET DINING ROOM LIVING ROOM MAIN FLOOR PLAN 1/4" = 1' BEDROOM 3 RECEIV CITY OF Tu E uA DEC 172010 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 ENGINEERS. 1N0 VN UCW I MID STOW 11I11 IN TAOON . 10A Op0•q.S ,OO71ou 07001 RI IIa FAX x001 aI S4N 0810.03.1217 O J z 0 z w z H- z 0 U z MPROVEMENTS 0 w w w 0 z LL U -J z w 0 (/) w AIP NUMBER 5 -53- 0058 -040 z 0 z f'— I"- Q DATE 7/1/10 ISSUED BID PACKAGE M -15 100% CD PROJECT ENGINEER JO PROJECT MANAGER ML &TF DRAWN LB &JH ELECTRICAL PLAN E1.0 0810.03.1217