HomeMy WebLinkAboutPermit D10-344 - PETITT RESIDENCE - IMPROVEMENTPET!JFI1 RESIDENCE
3938 S 113 ST
D1O -344
City okukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 3351400260
Address: 3938 S 113 ST TUKW
Suite No:
Project Name: PETITT RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D 10 -344
Issue Date: 03/01/2011
Permit Expires On: 08/28/2011
Owner:
Name: AVILA - PETITT KALIMAR A +DYLA
Address: 3938 S 113TH ST , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Phone: 206 296 -7437
Phone: 480 - 921 -4079
Expiration Date: 12/31/2011
DESCRIPTION OF WORK:
SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL
CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE INCLUDING: SOUND INSULATION WORK; VENTILATION WORK
AND UPGRADE; AND MISCELLANEOUS WORK TO WINDOWS, DOORS INSULATION, AND ABATEMENT.
Value of Construction: $31,964.00 Fees Collected: $1,141.27
Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0022
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D10-344 Printed: 03 -01 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
J1-
Date: 3 E
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perform ance of vyork. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: L Date: 3- 11
Print Name: C4441_511 &I A A(z_c- r+vi.ErA
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All wood to remain in placed concrete shall be treated wood.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
doc: IBC -7/10
D10 -344 Printed: 03 -01 -2011
Building Department (206- 431 - 3670).
•
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D10 -344 Printed: 03 -01 -2011
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: %iwww.ci.tukwila.wa.us
Building Permit No.
Mechanical Permit No.
PlumbinglGas Per
Public Wo
(For
e only
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 3938 S. 113th St.
Tenant Name:
Dylan Petitt and Kalimar A. Avila - Petitt
Property Owners Name: Dylan Petitt and Kalimar A. Avila - Petitt
Mailing Address: 3938 S. 113th St.
King Co Assessor's Tax No.: 3351400260
Suite Number: Floor:
New Tenant: ❑ Yes ®..No
Tukwila
WA
98168
City
State
Zip
CONTACT PERSON - who towe contact when yourpe
issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD
Alt plans must be wet stamped b
Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Zip
Contact Person: Melody Leung
or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
ENGINEER OF RECORD -
I plans must be wet stamped
by :Engineer of Reci
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application. doc
Revised, 1 -2009
bh
Page 1 of 6
BUILDING - PERMIT INFORMATION' -- 206 - 431 -3670
Valuation of Project (contractor's bid price): $ 1 64, Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
ovid
AI
Building Areas in Square Footage
to
st Floor
1,150
Addition to'
Existing
Structure'
Type of
Construction per
IBC
VB
Type of
Occupancy per
IBC
R3
2nd Floor
3r4 Ft
Floors
sement
Aceessor
e*
Attached Garage
ched Gai
ge
Attached Carpo
Detached Cat
Covered Deck
Uncovered De
k
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
11 \Applications\Forms- Applications On Line \2009 Applications \I-2009 - Permit Application.doc
Revised. 1 -2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR . ' IZED AGENT:
Signature: .if,
Print Name: ody Leung Timothy Fenlason Day Telephone: (206) 624 -2777
Date: e . 10
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle WA 98106
City
State
Zip
Date Application Accepted:
ri_ i n 1, to
Date Application Expires:
tte
1 it
[ t 1
Staff Initials:
H \Applications \Forms - Applications On Line \2009 Applications\ I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
�J�`N1LA wqs City of Tukwila
o `�2 Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 3351400260
Address: 3938 S 113 ST TUKW
Suite No:
Applicant: PETITT RESIDENCE
RECEIPT
•
Permit Number: 1)10 -344
Status: APPROVED
Applied Date: 12/17/2010
Issue Date:
Receipt No.: R11 -00283
Payment Amount: $693.45
Initials: TLS Payment Date: 02/15/2011 08:15 AM
User ID: 1670 Balance: $0.00
Payee: PAMELA K KUEHL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 030659
ACCOUNT ITEM LIST:
Description
693.45
Account Code Current Pmts
BUILDING - RES
STATE BUILDING SURCHARGE
000.322.100 688.95
640.237.114 4.50
Total: $693.45
doc: Receipt -06 Printed: 02 -15 -2011
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 3351400260
Address: 3938 S 113 ST TUKW
Suite No:
Applicant: PETITT RESIDENCE
RECEIPT
Permit Number: D10-344
Status: PENDING
Applied Date: 12/17/2010
Issue Date:
Receipt No.: R10 -02526
Initials:
User ID:
JEM
1165
Payment Amount: $447.82
Payment Date: 12/17/2010 10:50 AM
Balance: $693.45
Payee: KING COUNTY
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 669601 447.82
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - RES
000.345.830 447.82
Total: $447.82
doc: Receiot -06 Printed: 12 -17 -2010
INSPECTION RECORD
Retain a copy with permit
I SP CT ON NO. PERMIT NO.
• 'CITY OF TUKWILA BUILDING DIVISION O
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
,(o'3 -11
Projgt-:
t '1rTr f.
Type of Inspection:
ftAJit L
$L; 1 J,�(.)
Address: -
3g3k 113
Z.•
S
Date all d:
l c.pn _
i
�." et.,
Special Instructions:
�7/� E--- CSA
•
Date Wanted:
. �
,-,/, ,-,/,
a.m.
,P.17
Requester:
Phone No: 5'
5
Approved per applicable codes. EJ Corrections required prior to approval.
COMMENTS:
,P% M `i /.a hl (P1-,0
0K. ( A.1./k/ .A7
Me Ai.
Inspegfor:
Date' r.„14
REINSPECTION FEE REQUIRED. Prior to next inspection..fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
P, fe-11.27---7772-W ' '177--F" -T.'17.77.717.4";
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IA •
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Ot o - 344
Prcct:
. ljf"--rrrr.
PscS
Type-of Inspection: -
go JO( -IA/ itit el CA
Address:
3 3 &'
--Cs.
II 3 ST
Date Called:
Special Instructions:
Date Wanted:
7 ,.. 2,49 .4( ...757_,Ta.rni..
Requester:
Phone No:
0 c - E-'14. - oel ( 0
IKZpproved per applicable codes. OCorrections required prior to approval. 1- j
COMMENTS:
fsp
11
RE
Date:
2. I
SPECTION FEE EQUIRED. Prio to next inspection, fee must be
d at 6300 Southcenter Blvd., Suite 00. Call to schedule reinspection.
4
r.
4
1
06 -30 -2011
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D10 -344
3938 S 113 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 08/28/2011.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 08/28/2011, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
-1,..z0 '4,..-
Bill Rambo
Permit Technician
File: Permit File No. D10 -344
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
PPERMT COORD C6Pil
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D10 -344 DATE: 12/17/10
PROJECT NAME: PETITT RESIDENCE
SITE ADDRESS: 3938 S 113 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPART E CTS: \ k1
Building Division 1
Plevoit'sVc
ire Prevention
Structural
n
NA19421tZ
Planning Division
Permit Coordinator n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 14
Comments: 77
Incomplete
DUE DATE: 12/21/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route Structural Review Required ❑ No further Review Required n
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 01/18/11
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Prjpter Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
G & G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
Parent Company G & G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2011
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
FIRE INS
CO
59BSBEA9058
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.0001/03
/2011
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
CEOXINGTON INS
4392611702
12/31/2010
12/31/2011
$1,000,000.0001
/11/2011
1
CEOXINGTON INS
4392611701
12/31/2008
12/31/2010
$1,000,000.00
01/14/2010
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip /Print.aspx 03/01/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00570C10 BID PACKAGE M -15
5- 53- 0058 -040
SEPARATE PERMIT
REQUIRED FOR:
Er Mechanical
u tlectricat
IrPIumbing
3/Gas Piping
City of Tukwila
E 1_rli.1:”NG DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
FI
Permit No.
E COPY
Pi €n review approval is subject to errors and omissions.
4pproval of construction documents does not authorize
t ; .
Violation of any adopted code or ordinance. Receipt
01 approved Field Cop ,and s is ac kriowled9ed
By
Date: Q.1: - / O - ?-o/ l 3--
City Of lbkwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Developement
City of Seattle, WA
APPLICABLE CODES:
2006 Seattle Residential Code,
international Fire Code,
International Mechanical Code
335140 -0260
LEGAL DESCRIPTION:
HILLMANS C D MEADOW GARDENS "3
ZONING: 5F1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
No permitted information is available.
BUILDING AREA: No change to building footprint.
Addition:. 0 s.f.
Remodel: 0 s.f.
Sound Insulation: 0 s.f.
DRAWING INDEX
TO.0 TITLE SHEET, PROJECT INFO.
A1.0 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHEDULE 4 DETAILS
42.1 DOOR TYPES, SCHEDULE 4 DETAILS
422 MISCELLANEOUS DETAILS
42.3 WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX
M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS
E1.0 ELECTRICAL PLAN
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206. 296. 0190
Contact: Sharyn Parker
E- mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
511. Stemper Architects P.L.L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206. 624. 2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerresmstemper.com
melodymsmstemper.com
timesmstemper.com
ACOUSTICAL ENGINEER:
55A Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206. 839. 0824
Contact: Mohamed Alt Allaoua
E -mail: mohamedessaacoustics.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206. 318. 0641
Contact: Derek Orkney
E -mail: derekoegreenbusch.com
ELECTRICAL ENGINEER:
Tres West Engineers
2102 5. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253. 412. 3463
Contact: Brent Rollins
E -mail: bcratreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206. 162. 4180
Contact: Tim Ogden
E -mail: tim ogdenspbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. "200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwelleJonespayne.com
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 06 2011
City D ON
RECEIVF,
CINOFTUic LA
DEC 17 2010
PERMIT CENTER
VICINITY MAP (NTS)
3938 S 113TH ST
TUKWILLA, WA 98168
DI o•-•
S.M.STEMPER
ARCHITECTS
A Professional Limited LIabitity Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
RECl 11=1 f::D
sjnrE OF 111 'vrf� . Ncr
12/6/10
3938 S 113TH ST
0
0
2
W
Q
z W
O
z
1- g
z v
0 <
0 z
W
0
uJ
I.J..
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -040
SEATTLE WASHINGTON
DATE
12/6/10
ISSUED BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1217
NEW 24" x 24"
ATTIC ACCE
42.2
IN
NORTH
NOTE:
1 LEAD PAINT
AND 02081,
RESENT AT TH15' SIDENCE. REFER,to SECTION
CONTRACTOR TO PROTECT 0
2. CONTRACTOR TO TEMPORARILY
ORIGINAL LOCATIONS.
ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALE
ALVAGE. PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 0
FU- NITURE AN
MOVE FURNITUF
I.
OS SESSIONS FROM DAM. E AND DUST.
ONTENTS, WALL HANGINGS AND FIXTURE
NOTE:
EXTERIOR TR
UIRED AND RETURN THEM TO THEIR
TO 5:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE ANC) ROOMS IN THE RESIDENCE FOR WEEKENDS.
OORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 1S ON SITE REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME' DAY BETWEEN S :00` AM AND S:00
FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
ALL WORK AREAS SHALL BE BROOM-CLEANED AT THE END OF EACH WORK DAY.
PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY REF: ELECTRICAL AND MECHANICAL
WHERE SOFFITS A N D /OR MEC H.' COMPONENTS INTERFERE WITH (E) CLOSET SHELVING , DEMO (E) SHEL V ING AS REQ D AN D RE CON
STR RU
CT
A (E) CONFIGURATION
ITH TS AN /O MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TOM MATCH rE ,
SHELVING IN COORDINATION W SOFFITS AND/OR E L
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE. RECONSTRUCT SHELVING 60 AS NOT TO INTERFERE; WITH THE OPERATION OF
fiECHANIC41. UNIT ACCESS HATCHES.
ENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
HERE CEILING FINISHES ARE DISTURBED BY THE WOK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVEF
DES OF TEXTURE AND DENSITY I OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE 'PROJECT
Al (N. REEL4CEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COATS
ALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPE TED SM DETECTORS. SEE ELECTRICAL
SHEET El.c FOR LOCATIONS AND DETAILS OF INTERCONNCTED SMOKE DETECTORS.
TALL SAFETY GLAING PER CODE. SEE WINDOW TYPE SCHEDULE.
AXIMUM POWER MT IS EIGHT a' PO R T BE "'•VIDED AT SIDENCE BE FO S: A.M.
EMOLISH' ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WO REFER TO ELECTRICAL
FOR TIMER LOCATION
RONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUI ENT. JURISDICTIONAL CLEARANCE: 3'" CLEAR N FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT - CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICA_.
DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
EXISTING WINDOW "COVERINGS MUST BE REINSTALLED ON THE SAME DAY' AS COMPLETION OF WINDOW INSTALL. IF UJINDCUJ COVERINGS` ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST E PROVIDED.`
PLAN KEYNOTES
DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW
HEDULE ON SHEET A2.0
DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH
MECHANICAL.
INSTALL NEW THERMOSTAT COORDINATE WITH MECHANICAL
INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER
INSTALL FIREPLACE CAP AT (E) CHHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES.
INSTALL ROOF MOUNTED BAFFLE' TO (E) KITCHEN EXHAUST REF. 2/422 FOR DETAIL
CAREFULLY CUT INTO (E) CEILING TO INVESTIGATE` EXISTING ATTIC CONDITION. INSTALL NEW ATTIC ACCES PANEL, REF. 4/42.2 FOR DETAIL,
COORDINATE (SOFFIT WITH EXISTING MILLWORK.
ACCESS TO SITE AND PARKING
THE CONTRACTOR AN THEIR SU ONT CTORS SHALL NOT PA OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
S.M.STEMPER
ARCHITECTS
A Professional. Limited Liability Ca
4000 DFLRIDGEWAY
SUITE 200 • SEATTLE, WA
(200)'624-°2777 • FAX (206) 624
12 /(c' /10
z
0
Z
Z
0
Z
0
z
z
z
EAST E
AIP NUMBER
53- 0058 -040
LEGEND
ACOUSTICAL WINDOW
NOT USE
NOT USED
DATE
12/6/10 ? `
ISSUED BID PACKAGE 'M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
&TF
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.0
OW SCHEDULE
ENDOW TYP
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANE
ATHER TEXTURED CEILING OVER AT A
IN. OF 24" FROM EDGE OF PATCHING.
ATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
ILINC DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF, MECH. 4 ELECT.
F. GENERAL NOTE 11
OR
FRESH AIR INTAKE GRILLE
FOR UNIT.
VENT BAFFLE
ATTIC IN
ULATION
FLOOR
PLANS
NOTES
BATTERY OP
DETECTORS
cosavi
DEC
KITCHEN EXHAUST VENT BAFFLE
ETER
A1.0
0810.03.1217
WINDOW TYPES
SLIDER
2
FIXED OVER
CASEMENT
3
FIXED OVER
FIXED
4
FIXED
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
DINING ROOM
1
3' -10" x 2' -4"
PAINT/PAINT
-
1/A2.0
B
LIVING ROOM
1
3' -10" x 2' -4"
PAINT/PAINT
I/A2.0
C
LIVING ROOM
2
2' -2" x 4' -11"
PAINT/PAINT
2/42.0
D
LIVING ROOM
3
3' -11" x 4' -11"
PAINT /PAINT
2/42.0
E
LIVING ROOM
2
2' -2" x 4' -11"
PAINT/PAINT
2/42.0
F
KITCHEN
4
I' -9" x11-9"
PAINT/PAINT
2/42.0
G
KITCHEN
1
3' -10" x 3' -4"
PAINT/PAINT
1/A2.0
H
BEDROOM 1
I
3' -10" x 2' -4"
PAINT/PAINT
I /42.0
I
BEDROOM I
I
4' -11" x 2' -9"
PAINT/PAINT
1/42.0
J
BEDROOM 2
1
4' -11" x 2' -11"
PAINT/PAINT
I/42.0
K
BEDROOM 3
I
3' -11" x 2' -9"
PAINT/PAINT
I/42.0
(E) = EXISTING
WINDOW TYPE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING UIINDOUJ OPENING DIMENSIONS.
(E) UJD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) UOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN TIE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) WALL UNDERLAYMENT
(E)Y" EXT. SHEATHING
SELF ADHERING
MEMBRANE
HARDWOOD TRIM TO
MATCH (E), PAINT /STAIN
TO MATCH (E) TRIM
UJD. JAMB LINING
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E)1/2" EXT. SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
WINDOW HEAD
WINDOW JAMB
l�f
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE U/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXT. SHEATHING
(E) UJD SIDING
1
f
WINDOW SILL
(E) GLIB
HARDWOOD TRIM TO
MATCH (E), PAINT /STAIN
TO MATCH (E) TRIM
IUD JAMB LINING
SEALANT
BACKER ROD 4
SEALANT
3/4" W. SILL - STAIN TO
MATCH (E)
HARDWOOD TRIM TO
MATCH (E), PAINT /STAIN
TO MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GUB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) T -III SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) T -111 SIDING
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE UINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) T -1II SIDING
(E) WALL UNDERLAYMENT
(E) I/2" EXT. SHEATHING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E)
TRIM. COLOR TO BE FIELD
DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
WINDOW HEAD
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAIL FLANGE
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) T -111 SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/
NEW SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E)
SIDING
(E) I/2" EXT. SHEATHING
[71
WINDOW JAMB
(E) GLOB
(E) WALL UNDERLAYMENT
(E)Y" EXT. SHEATHING
SELF ADHERING MEMBRANE
IARDUOOD TRIM TO MATCH
(E), PAINT /STAIN TO MATCH
(E) TRIM
UJD. JAMB LINING. FINISH TO
MATCH (E)
SEALANT 4 BACKER ROD
(E) GLIB
WD JAMB LINING
SEALANT
/8"
• let
WINDOW SILL
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN
TO MATCH (E)
HARDWOOD TRIM TO
MATCH (E),
PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GWB
2 T_111 SIDING - WINDOW DETAIL SET
3 =1 -0
bo34y
REVIEWED FOR
CODECOMPLIANDE
Aponnven
JAN Os 2011
City of Tukwila
BUILDING DIVISION
RECEIV
CITY OF TU LA
in 172010
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, IYA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
/ £HITECT
SCOTT !jTE!MPER
STATE OF ASHINGTON
I2/6/10
3938 S 113TH ST
I--
O
0
J
z
0
I---
Q
z
w
z
1--
z
0
0
z
MPROVEMENTS
0
Cw
w
w
0
z
LL
0
J
z
w
0
w
AIP NUMBER
5 -53- 0058 -040
DATE
12/6/10
ISSUED
BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1217
DOOR TYPES
1.61
Bo
0
;j
,4
FLUSH SCW
HALF -LITE W/
4 PANELS
W/ SAFETY GLAZING
FLUSH SCW
W/ SIX PANELS
W/ OBSERVATION
PORT
G
EXTERIOR
SINGLE LEAF
STORM W/ SAFETY
GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY 1
B
2' -10" x 6' -8"
PAINT/PAINT
HW -I / 116
DK -2
LOCK -1
1/42.1
2
ENTRY 2
A
3' -0" x 6' -1"
PAINT /PAINT
HW -1 / 116
DK -2
LOCK -1
2/A2.1
3
ENTRY 1
C
2' -10" x 6' -8"
4
ENTRY 2
C
3' -0" x 6' -1"
REMOVE (E) T -111 SIDING AS REQ'D FOR
INSTALLATION OF DOOR ASSEMBLY 4
TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF
SELF - ADHERING MEMBRANE AGAINST
SHEATHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF - ADHERING MEMBRANE.
TYP AT HEAD AND JAMB
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
CAREFULLY CUT BACK (E) T -1II SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) T -1I1 SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR SHOE
2" MIN.
1
DOOR HEAD
■
SELF ADHERING
MEMBRANE
(E)Y" EXT. SHEATHING
2" MIN.
DOOR JAMB
AUTOMATIC DOOR SWEEP
OAK AND METAL THRESHOLD
ADJUSTABLE SWEEP
HARDWOOD TRIM TO MATCH
(E), PAINT /STAIN TO MATCH
(E) TRIM
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS
WEATHER STRIPPING
DOOR PER SCHEDULE
(E)Y" EXT. SHEATHING
EXISTING FRAMING
HARDWOOD TRIM TO MATCH
(E), PAINT /STAIN TO MATCH
(E) TRIM
FILL CAVITY W/ BATT
INSULATION
DOOR PER SCHEDULE
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
(E) BALCONY FLOOR 4 DECK
DOOR SILL
T -111 SIDING - DOOR DETAIL SET
3 " =1' -0"
DOOR TYPE NOTES
1. NOTE: WHERE SAFETY GLAZING 15 INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
REVIEWED FOR
CODE COMPLIANCE
APPRIWED
JAN 0 6 2011
City of Tukwila
BUILDING DIVISION
cm�ERIVIu+
DEC 17 2010
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
A CHITEGT
'COTT t TEMPE
STATE OF IvASHINGTON
3938 S 113TH ST
12/6 /10
O
0
J
z
z
w
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
0
ww
w
w
0
z
0
J
z
w
0
w
5 -53- 0058 -040
z
0
0
z_
Cn
I—
I—
Q
DATE
12/6/10
ISSUED BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1217
EXISTING
CEILING
STRUCTURE
(E) BACKER BOARD
(E) VINYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF ELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDING AS REQ'D FOR
INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE U/ NEW SIDING,
ACCESSORIES, * BLOCKING TO MATCH (E).
PRE — PRIMED, GALV SHEET METAL
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.— PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. ET IN MASTIC AT
EXTERIOR TRIM.
REPLACEMENT SIDING AS REQUIRED
SHIM BACKER BOARD AS
REQUIRED
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
(E)Y" EXT. SHEATHING
2X2 BLOCKING, 4 SIDES
(P.T.)
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
FINISH TO MATCH (E) PAINT AND
TEXTURE
L J
SOFFIT DETAIL
ATTACH 2x3 LEDGER TO EXIST. DECK
ATTACH SOFFIT FRAMING TO LEDGER
DUCTS PER PLAN WITHIN SOFFIT
RE: MECHANICAL
2x2 CONT. NAILER
%8" GUB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE U/ ADJ
ARCHITECTURAL FEATURES PER PLAN.
COORDINATE SOFFIT DIMENSIONS UITH
MECHANICAL
(E) UD FRAME UJALL ASSEMBLY
1 1/2" = 1' - 0"
tO34Lf
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
1' -2 5/5"
DAMPER ROD
DAMPER FLAP
PREMANUFACTURED ROOF
BAFFLE (GROAN— MODEL
634)
— BIRD SCREEN
SCREW
7461'
4" DAMPER PLATE
1' -6 3/4° SEALENT STRIP
SECTION
PREMANUFAGTURED ROOF
BAFFLE (GROAN- MODEL
634)/
EXISTTIG DUCTWORK
SEAL ALL NAILS WITH ROOF
CEMENT
y5EAL SHINGLES TO ROOF
GAP ON TOP AND SIDES
NOTE:
I. PREMANUFACTURED ROOF BAFFLE. INSTALL PER
MANUFACTURE'S INSTRUCTIONS.
KITCHEN EXHAUST BAFFLE
3" = 1' - 0"
PIVOT HINGE
CAULKING ADHESIVE
INSTALL 2X BLOCKING
AROUND OPENING AND
FASTEN EDGES OF
DRYWALL TO BLOCKING.
ASSUME (E) CEILING
JOISTS 6 24" O.C. EXTEND
BLOCKING TO ( E) CEILING
JOISTS (TYP)
(E) GWB
SNAP FRICTION CATCH
REMOVABLE DOOR
PAINT DOOR AND FRAME
TO MATCH (E) COLOR OF
CEILING
ATTIC HATCH & PANEL DETAIL
3 " =1' -0"
jn5 ✓lNr's e., ,.
it/ __6Jr, 4yzCC (
2t- �
{a mvfS �W � ✓q
A cf;),-, 6 /etc
--REVIEWED FOR'
CODE COMPLIANCE
JAN 06 2011
City of Tukwila
BUILDING DIVISION
INSULATION DAM DETAIL
3 " =1' -0"
INSULATION
ROOF DAM
(E) WALL FRAMING
RECEIV
CITY OF TU WILA
Utz • 17 2010
PERMIT CENTER
i
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
4220
REGISTERED
ARCHITECT
SCOTT !WTEMPE�
STATE OF I.. ASHI dGTON
3938 S 113TH ST
12 /6 /IO
O
0
J
z
0
F-
it(
z
w
z
1-
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
0
cnw
w
w
0
z
LL
0
J
z
w
0
w
5 -53- 0058 -040
DATE
12/6/10
ISSUED BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
MISC.
DETAILS
A2.2
0810.03.1217
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
• (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
` \ HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I i"
BEYOND R.O. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
II" MIN
TYP.
I/
MEMBRANE FLASHING AT SILL
5a
BUTTERFLY CORNER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
WINDOW NAIL FLANGE:~
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
o o
0
0
O
0
0
0
0
0
0 0 0
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
4 WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOUJN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOUIN OVER
FLANGE
FLASHING AT
JAMBS
(8
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
1
WHERE REQUIRED, TRIM
(E) BLDG RAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRI
(FOLLOWIN STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
(21
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 5HOU,N FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
11/2" TYP.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND I -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL 51—IEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
0
0
0
0
0
0
0
0
3
TYP:
Ci
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
�� MEMBRANE FLASHING AT SILL
} SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOUJN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
ALLOW I/8" CLEARANCE
BETWEEN FLASHING AND
BOT. EDGE OF (E)
—� -1 SIDING.
TRIMMED EDGE OF (E)
BLDG PAPER
9� HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING A5
SHOWN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
(3\\ MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
1
0
0
0
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
(,in WOOD TRIM INSTALLATION
SCALE: NTS
GENERAL NOTES:
1: MEMBRANE FLASHING 15 SPECIFIED IN 0121145 "SELF
APHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1-1,45 BEEN SET IN PLACE,
51-1IMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
0
0 0
J
J
E7)
WINDOW FLASHING INSTALLATION
SCALE: NTS
bIo.3'14
REVIEWED FOi
CODE COMPLIANCE
APDQfVED
JAN 0 6 2011
City of Tukwila
BUILDING DIVISION
RECEIV
C)TVOFTI� LA
DEC 17 2010
PERMIT CENTEF
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
3938 S 113TH ST
I2/6/10
O
0
J
z
0
z
w
z
E-
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
Cw
w
w
0)
0
z
I-
LL
U
J
z
w
0
w
5 -53- 0058 -040
z
0
CD
LU
z
J
I-
E-
Q
Lil
Cn
DATE
12/6/10
ISSUED BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1217
1/
(,in WOOD TRIM INSTALLATION
SCALE: NTS
GENERAL NOTES:
1: MEMBRANE FLASHING 15 SPECIFIED IN 0121145 "SELF
APHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 1-1,45 BEEN SET IN PLACE,
51-1IMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
0
0 0
J
J
E7)
WINDOW FLASHING INSTALLATION
SCALE: NTS
bIo.3'14
REVIEWED FOi
CODE COMPLIANCE
APDQfVED
JAN 0 6 2011
City of Tukwila
BUILDING DIVISION
RECEIV
C)TVOFTI� LA
DEC 17 2010
PERMIT CENTEF
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
3938 S 113TH ST
I2/6/10
O
0
J
z
0
z
w
z
E-
z
0
U
z
AIP NUMBER
MPROVEMENTS
0
Cw
w
w
0)
0
z
I-
LL
U
J
z
w
0
w
5 -53- 0058 -040
z
0
CD
LU
z
J
I-
E-
Q
Lil
Cn
DATE
12/6/10
ISSUED BID PACKAGE M -15
PERMIT SET
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1217
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TD H
TOD
TP D
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WSVIAQ
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON STATE VENTILATION AND INDOOR AIR
QUALITY CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
OR XX
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
X/Y
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
}
SYMBOL
SG -X
XXX
ABBR
S
}
-+ICE
>CI
0
101
EQUIP IDS _ OR OP
NG
•
0
r,t(i
1
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA /EA
RG
SA
SA
RA /EA
SD
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
PROVIDED
UNDER DIVISION
FURNISHED /MOUNTED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
383
<.08 "WG
8/4
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
85
383
<.08 "WG
8/4
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
2006 WSVIAQ
DUCT LOCATION 1 MIN VALUE NOTES
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1217
1307
3
75 -113 CFM
85 CFM
R -5
1
1. VENTILATION PROVIDED PER THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY
CODE, TABLE 3 -2
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
MINIMUM INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE LIMITED REGULATED MATERIALS REPORT AND LAB
ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM
PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL
AREAS REQUIRING ABATEMENT. REFER TO SPECIFICATION
SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS
ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SPECIFICATIONS SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
RECEIVE,
CITY OF TUKKWVIL
'.ate 17 2010
PERMIT CENTER
REVIEWED FOR
CODE COMPLIANCE
APDRf111ED
JAN 0 6 2011
City ofTukwila
BUILDING DIVISION
EXPIRES: 9/08/2010
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 9B106
(208) 824 -2777 • FAX (206) 824 -2973
THE GREENBUSCH GROUP, INC
41111110111910010)
ACOUSTICAL AUDIO / VIDEO & MECHANICAL ENGINEERING
1900 WEST NICKERSON STREET SUITE 201 SEATTLE. WA 98119
(206) 378 -0389 (208) 378 -0841 FAX
0810.03.1217
0
0
J
z
0
z
w
1--
z
F-
z
0
U
z
MPROVEMENTS
0
w
2
w
w
0
z
L
U
J
I—'
z
w
0
W
AIP NUMBER
5 -53- 0058 -040
z
0
0
z
Cn
DATE
7/1/10
ISSUED BID PACKAGE M -15
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
DO
DRAWN
CA, DO & MM
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1217
SEE
x
(E)SG
BEDROOM
1
(E)EF
BATH 1
KITCHEN
CEILING
(E)SG
BEDROOM
2
x
(E)
SG
6 "o4
1-
I
L
0
N
1
J
CLO5ET
DINING
ROOM
LIVING
ROOM
(E)SG
(E)SG
(E)SG
x
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" =
FLOOR
(E)RETURN
FURNACE
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
MOD, INTERLOCK TO
FURNACE
POC
CLOSET WALL, TYP
BOTTOM SUPPLY
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
BEDROOM
3
4." NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
NOTES:
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
3
WALL CAP CONNECTION DETAIL
SCALE: NONE
DRAWING NOTES:
1. RESIDENCE WILL BE FULL CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY
CODE, CHAPTER 3 (CONTROLS FOR WHOLE HOUSE VENTILATION
SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION
SYSTEM WITHOUT ENERGIZING OTHER ENERGY — CONSUMING
APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WSVIAQ 303.4.2.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM
INSULATION SCHEDULE ON M1.0.
ROUTE DUCT IN SOFFIT TIGHT TO CEILING.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WSVIAQ.
bto-•14
p�
PARATE
APP M1TAND
REQUIRED
ifiFTIE�Y
crIYOI L.A
DEC
PERMIT t.•N i't:04
EXPIRES: 9/08/2010
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824 -2777 • FAX (206) 824 -2973
THE GREENBUSCH GROUP, INC
ACOUSTICAL. AUDIO / VIDEO & MECHANICAL ENGINEERING
1900 WEST MCIORSON STREET SUITE 201 SEATTLE. WA 98119
(206) 378 -0369 (206) 378 -0641 FAX
0810.03.1217
0
0
J
z
O
z
w
z
z
0
U
C9
z
MPROVEMENTS
0
w
w
w
0
z
LL
U
C
(1)
J
z
w
0
w
AIP NUMBER
5 -53- 0058 -040
z
0
0
z
Cn
w
I--
I-
CO LLI
DATE
7/1/10
ISSUED BID PACKAGE M -15
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
DO
DRAWN
CA, DO & MM
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1217
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT
TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND
PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE MOTOR RATED TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O2 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
3O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SCHEMATIC DIAGRAM.
L
L
L
N
N
>
0
N
N
TIMER
SWITCH
SET FOR 8HR
PER DAY.
SEE MECH.
HI-
120V
I I
1 I -1
30/1
RELY 120V
30/1 IS. 24V
RELAY
30/1
1-
OUTSIDE AIR
DAMPER
SEE MECH
MANUAL
STARTER
SWITCH
J
RELAYS1
rrY124V -I 1—
� I
1
J
PROGRAMMABLE
T -STAT, SEE MECH
SUMMER MODE SCHEMATIC DIAGRAM
NOT TO SCALE
NOTE: THE SCHEMATIC DIAGRAM ABOVE IS BASED ON A GENERIC
CONTROL SCHEMATIC AND IS NOT INTENDED TO REPRESENT EXACT
CONDITIONS OR SPECIFIC REQUIREMENTS. CONTRACTOR TO ALLOW
IN BID, COSTS TO STUDY EXISTING FURNACE AND DEVELOP THE
INTERLOCK CONTROL REQUIRED FOR SUMMER MODE OPERATION
SIMILAR TO THE CONTROL DEPICTED ABOVE.
1
SUPPLY (
FAN >�
SEPARATE
FROM HEAT
1
< > HEAT
<>
I
1
J
ELECTRICAL_ LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
IJGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNEC11ON SCHEDULES
FOR SPECIFIC REQUIREMENTS.
®
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
111111
4
DAMPER CONNEC11ON
D
NON -FUSED DISCONNECT SWITCH
o
MAST, WEA1HERHEAD
Qs'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
®D
SMOKE DETECTOR
ELECTRICAL METER
I
TIMER OPERATED SWITCH
,,-
I-1
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
CT
THERMOSTAT
— - —
BEDROOM
1
BATH 1
KITCI -TEN
QIN
NORTH
BEDROOM
2
TO FURNACE
POWER SUPPLY
CLOSET
DINING
ROOM
LIVING
ROOM
MAIN FLOOR PLAN
1/4" = 1'
BEDROOM
3
RECEIV
CITY OF Tu E uA
DEC 172010
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
ENGINEERS. 1N0
VN UCW I MID STOW 11I11 IN
TAOON . 10A Op0•q.S
,OO71ou 07001 RI IIa
FAX x001 aI S4N
0810.03.1217
O
J
z
0
z
w
z
H-
z
0
U
z
MPROVEMENTS
0
w
w
w
0
z
LL
U
-J
z
w
0
(/)
w
AIP NUMBER
5 -53- 0058 -040
z
0
z
f'—
I"-
Q
DATE
7/1/10
ISSUED BID PACKAGE M -15
100% CD
PROJECT ENGINEER
JO
PROJECT MANAGER
ML &TF
DRAWN
LB &JH
ELECTRICAL
PLAN
E1.0
0810.03.1217