Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D10-351 - WESTFIELD SOUTHCENTER MALL - MICHAEL KORS - LANDLORD PORTION
MICHAEI. KORS LANDLORD PORTION 515 SOUThCENTER MALL D10 -351 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwi la. wa. us DEVELOPMENT PERMIT Parcel No.: 9202470010 Permit Number: D10-351 Address: 515 SOUTHCENTER MALL TUKW Issue Date: 02/01/2011 Suite No: Permit Expires On: 07/31/2011 Project Name: MICHAEL HORS - LANDLORD PORTION Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WY SW #200 , SEATTLE WA 98106 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Contractor License No: BNBUII *990K3 Phone: 206 624 -2777 Phone: 206 382 -3443 Expiration Date: 09/12/2011 DESCRIPTION OF WORK: LANDLORD BUILD -OUT OF NEW TENANT DEMISING WALL AND LANDLORD STORAGE AREA Value of Construction: $25,000.00 Fees Collected: $937.25 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N doc: IBC -7/10 D10-351 Printed: 02 -01 -2011 Permit Center Authorized Signature: Date: 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. lthorized to sign and obtain this development permit and agree to the conditions attached to this permit. V J Signature: Print Name: IN\a r9 -_ A.. 1----11L... v-.1 /A 11./"� Date: 2 ' 1 ' 1 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot doc: IBC -7/10 D10-351 Printed: 02 -01 -2011 be completely avoided, means shall be pro d to indicate the locations of the extinguish is ou IFC 906.6) 13: Extinguishers shall be located in consp s locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 15: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 20: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 21: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 22: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 26: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM CONTROL PANEL.) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) doc: IBC -7/10 D10 -351 Printed: 02 -01 -2011 29: All new fire alarm systems or modificati existing systems shall have the written ap of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtain City Ordinance #2051) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Post address on storefront per approved Westfield standards. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D10 -351 Printed: 02 -01 -2011 s .T! CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 izttp: //-1;11,11,.c.i.tulcwila.wa.us Building Per Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No.''%�''' office Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2 (v 2O'/ - /023 Site Address: 5 7 5S S 0Grrf /G EA ireg.. P74 1.-1—. Suite Number: 67 2. Floor: / 5T Tenant Name: d.,[E S7TF7ELJ New Tenant: ❑ Yes Z..No Property Owners Name: 1.4-/�/4- Se, t j 7-7-1e-EA/721Z_. Mailing Address: 2 23 00 Soc.477/e AI7C/ p7AL.L / S TA-771C /t, /4 181138 City State Zip CONTACT PERSON -, do we cos your permit is ready to be iss sd' Name: 411,4 4./E" ,JD ifr -/svA1 Mailing Address: 4/Oov 27E1.-/e/66 1414:" 2-06 ski%% t AO 98/" City State Zip Fax Number: 20 6 •6Zy 2T 73 Day Telephone: 2o - 6 217 • 27 77 E -Mail Address: //i4 %/4 SM S7T r7 2 • L oM GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gs Piping (pg 5 Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT' F RECORD - Ail,)Ptans must be wet sta. led by Arebit Record Company Name: Mailing Address: S M. 5 rtMPt .4eG<1 /71--c.,73 / 'O) /i/,9Y 3; 7 '1t246 Contact Person: /AYA/a -- — /o///` -/ J E -Mail Address: /,QWi7C/t /e__ . Ga/✓! cJZ fO /D to City State Zip Day Telephone: 2D ' • 62'7 27 7 7 Fax Number: 24)6 '62 "2973 ENGINEER OF RECORD - All plans must be et stamped by Engineer of Record Company Name: Mailing Address: A/ /4 City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q \ApplicationsTorms- Applications On Lineg -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of6 rBUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 2S, 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): 1- A- b 8u /L.1) -- ) or-. or A/4V 7.-k7V /7 L ea. Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. rovide MI Building Ar eas quare Footage Below oor GG 3 7 27 Interior Remodel 2,/5337 Addit Exit Si Ty1 Constructioi MC _8 Type of Occupancy per ,77" B Floa�rs Basement Access() Attached Garage Detached Gana; Attached Carport Detache C Covered Deck Uncovered Deck, PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) /�/4 Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. *For an Accessory dwelling, provide the following: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: yi Sprinklers �Q�,AutomaticcFFiiree Alarm / Will there be storage cruse of ami" fiabl`�mb tub igl'e oazrdous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. ❑ None ❑ Other (specify) Q.\ApplicationsTorms- Applications On Line \3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT A 'P1 CATION NOTES — Applicable this Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE ' OR AUTHORIZED G T: Signature: Print Name: .47 ,..1C)//-A.(Seird Mailing Address: 4/006 /2L./2 /,»Ge.- /c/A-,.57,1 o Date: /Z /Ze /c) Day Telephone: 20g ' 62-57- Z 7 77 City State Zip Date Application Accepted: I V72 1,0 Date Application Expires: �o I ' Staff Initials:I" 4 QA\ApplicationsTorms- Applications On LineU -2006 - Permit Application. doc Revised. 9 -2006 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-351 Address: 515 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 12/28/2010 Applicant: MICHAEL HORS - LANDLORD PORTION Issue Date: Receipt No.: R11 -00192 Initials: User ID: Payee: WER 1655 Payment Amount: $569.80 Payment Date: 02/01/2011 03:25 PM Balance: $0.00 MAR; HILLIARD TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11714 569.80 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 565.30 640.237.114 4.50 Total: $569.80 doc: Receipt -06 Printed: 02 -01 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10 -351 Address: 515 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 12/28/2010 Applicant: MICHAEL KORS - LANDLORD PORTION Issue Date: Receipt No.: R10 -02575 Initials: JEM User ID: 1165 Payment Amount: $367.45 Payment Date: 12/28/2010 04:10 PM Balance: $569.80 Payee: S.M. STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15809 367.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 367.45 Total: $367.45 doc: Receipt -06 Printed: 12 -28 -2010 INSPEC ON NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 it. . (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: Address: ..5 I s s C MAIL.- Date Called: Special Instructions: Date Wanted:. a.m. Requester: Ph2,o6;- 7IE---I 116 Approved per applicable codes. a Corrections required prior to approval. V A-v j i..i l — 4 .f -2/ ? , j i fir n ii ay.,s ! ! 0,/A/ev/ P!�►^� �` (...r-vv.vl /(-err Date' PECTION FEE REQUIR . Prior to ext inspection. fee must be d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Oro / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 • Permit Inspection Request Line (206) 431 -2451 . Project:' i'('#'9 I_ ,4/62 S • <; Type of Inspection: c'.?,,i,y /.✓ - ..S'49 el'A --it. Address: 5-/ 5 cSd'/7- devfoli M11-41; Date Called: . s. �6J 141401P) s d Ar 1. p, Special Instructions: . ei Date Wanted: _ . • .ft at..,. p.m. Requester: 1 Phone No: ,2404_- 4/5 ' -3 3 $ 5 -°Approved per applicable codes. 2D ® Corrections required prior to approval. l ' COMMENTS: .., • <; ..S'49 el'A --it. ro 8�/e>'�._ 1f6a d #d744 rd� - . s. �6J 141401P) s d Ar 1. p, 7�/ rtr v s - !f !0,5,A-4 /oiler -� reir- 9 ei 1 ) \ Inspec or: INSPECTION FEE REQIIRED. paid at 6300 Southcenter g vd.. S Date: ' P or to nex inspection, fee must be uite 100. Cal to schedule reinspection. 45215f9C;21144 eigplylta. ACM ...0.1:74.1 LA .4.71C, • a.nc IVamv -r..: Q:: .x..:- :: gi' -+as.e ..— "Weis 1. ••• .-. ..43!. INSPECTION NUM ER INSPECTION RECORD Retain a copy with permit Alts - S' I PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 s{{e: ,7.-.---74Wrip;wifig •.1 Project: 1 /.. ,5t-0( f•A� Type f Inspect' . 4 r kJ AL . Address: S• / ,- Suite #: .c . (V\4L (. Contact Person. Special Instructions: Monitor: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: r (e) Needs Shift Inspection: Sprinklers: Date: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: „ r Inspector: 7 (— Date: 7'i3/ (f Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • ;ti . • u; • • • • y • vat INSPECTION NUMBE INSPECTION RECORD Retain a copy with permit Ta- 3 5 f 1 / -C- by PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 - 206 - 575 -4407 Project: , enk `7Pa-C -C Type of Inspection: `iitze- A/a vrt., A- . Address: 5 , 5- Suite #: Se. . 1/In Q i ! Contact Person: L \ r L-- vc. + t; .-■ Sc << Tc.. < t k Special Instructions: i- ,.. ,*-e s ioire Phone No.: Z53- 972- 5 i 3 .Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: `I Fire Alarm: . Monitor: Lturir.Q; e.■, r ; re /a. IAA c ,Q. .x 01 e ,. i- ,.. ,*-e s ioire - .bi oL - ✓piCt Q Oac uk tiff' erc lb 47-1/c_ r,,,,a_e ',le e d 3) k‘)- PA- ;1 4 r pUL 5ov vie- ,e `71-;_t 6v+ Oda i, \A.5c„, , 5iArL, r/71 Needs Shift Inspection: Sprinklers: `I Fire Alarm: Hood & Duct: -- Monitor: Lturir.Q; e.■, Pre -Fire: Permits: _ Occupancy Type: Inspector: -""r Q )1._ rlAA t I Date: c, h7 / r/ Hrs.: 1.9 n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 c - • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit No — 35-/ //- S— eP3& •PERMIT NUMBERS CITY OrTUKVVILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 2O6-575-4O7 Project: V ec likaA SIT, 1 Pc r I 1'7- Type of Inspection: S P ci iu AL_ Address: Si r 5. • mott,L, ? Suite #: Contact Person: Special Instructions: 5AA-ce e741- Phone No.: ., dot9 - 6c.s-, cos--es E.,.Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: r-IfutevL On -t-ti mp (4'5W-3 Needs. Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor:.. Pre-Fire: Permits: : Occupancy Type: 'Inspector: • R,..k • .5,— I Date: 2 ii_i i• •irs:: • 1 • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from • the City of Tukwila Finance Department. Cait to schedule a reinspection. Word/Inspection Record Porm.Doc 1/13/06 n Department of Community Development Jack Pace, Director • City of Tukwila Jim Haggerton, Mayor 08 -01 -2011 WAYNE JOHNSON 4000 DELR DGE WY SW #200 SEATTLE WA 98106 RE: Permit No. D10 -351 515 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/18/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 09/18/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c‘.R...L..._ Bill Rambo Permit Technician File: Permit File No. D10 -351 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 MPERM9TCOORD COPY a PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -351 DATE: 12/28/10 PROJECT NAME: MICHAEL KORS - LANDLORD PORTION SITE ADDRESS: 515 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: ' D peg 1 ®-' Bu li ding sio s I Public Wor s Fire Prevention Structural n i AiJ✓- P anning Division Permit Coordinator II DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 17KJ Comments: Incomplete n DUE DATE: 12/30/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route 11 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/27/11 Approved U Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople •ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name B N BUILDERS INC UBI No. 602056687 Phone 2063823443 Status Active Address 2601 4Th Ave Ste 350 License No. BNBUII'990K3 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/23/2001 State WA Expiration Date 9/12/2011 Zip 98121 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTESL913K1 WESTERN STATES LOGISTIX LLC Construction Contractor General Unused 5/8/2009 5/8/2011 Active BASTINB0000J BASTIAN NIELSEN BUILDERS INC Construction Contractor General Unused 9/11/2000 9/7/2001 Archived PURODSI984JN PURODI SYSTEMS INC Construction Contractor Plumbing Unused 6/19/2002 7/2/2010 Expired Business Owner Information Name Role Effective Date Expiration Date BASTIAN, BRAD President 05/23/2001 Bond Amount NIELSEN, JEFF Vice President 05/23/2001 6642084 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 INS CO OF AMERICA 6642084 06/02/2009 Until Cancelled $12,000.0006/05 /2009 4 HARTFORD FIRE INS 52BSBBK5617 01/01/2002 Until Cancelled 06/02/2009 $12,000.00 12/04/2001 3 TRAVELERS CAS & SURETY CO 103355900 08/30/2001 Until Cancelled 04 /07/2009 $12,000.00 09/06 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 ZURICH AMERICAN INS CO gta380504400 09/07/2010 09/07/2011 $1,000,000.00 09 /07/2010 11 WAUSAU UNDERWRITERS INS. CO TBJZ91442966029 09/07/2009 09/07/2010 $1,000,000.0009 /03/2009 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/2008 09/07/2009 $1,000,000.00 09/05/2008 9 WAUSAU BUSINESS INS CO TBKZ91442966027 09/07/2007 09/07/2008 $1,000,000.00 09/05/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 02/01 /2011 WESTFIELD MALL AT SOUTHCENTER TENANT DEMISING WALL - LANDLORD IMPROVEMENTS 515 SOUTHCENTER MALL SE :1 $ 2011 Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK N PREPARATION FOR FUTURE TENANT. SI�I����TI :: TENANT SPACE 612 TENANT ADDRESS: 515 SOUTHCENTER MALL TUKUJILA, WA 98188 TAX PARCEL NUMBER: 262304 -9023 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: 2,155 SF. TOTAL REVISED TENAT SPACE SQUARE FEET: 1600 SF TOTAL SQUARE FEET OF LANDLORD STORAGE AREA: 355 SF OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD (TABLE 1004.1.1): OCCUPANCY LOAD FACTOR - RETAIL AREA: 1,800 SF / 30 : 60 LANDLOARD STORAGE AREA: 355 SF / 300 • 2 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) REVISED TENANT SPACE 612: OCCUPANCY LOAD IS 60 THEREFORE TWO EXITS ARE REQUIRED. ONE EXIT IS CURRENTLY PROVIDED AT THE STOREFRONT FOR THE VACANT SPACE WHICH WiLL BE BARRICADED BY WESTFIELD UPON VACANCY. TENANT IS RESPONSIBLE FOR CONSTRUCTION OF SECOND EXIT FROM VACANT SPACE PER THE EGRESS REQUIREMENTS UNDER THEIR SCOPE OF WORK NEW LANDLORD STORAGE AREA: OCCUPANCY LOAD IS 2 THEREFORE ONE EXIT IS REQUIRED. ONE EXIT IS PROVIDED THEREFORE OK MINIMUM CORRIDOR WIDTH OF 44" - EXiSTNG AND PROVIDED THEREFORE ACCEPTABLE EGRESS WIDTH AT TENANT SPACE - 60 (.2) : 12 NCHES - PAIR OF 36" WIDE DOORS SHALL BE PROVIDED AT MALL STOREFRONT AND FUTURE DOOR TO BACK OF HOUSE CORRIDOR SHALL BE 36" WIDE - THEREFORE OK LANDLORD STORAGE AREA - 2 (2) :.4 INCHES - 36" WIDE EXIT DOOR IS PROVIDED THEREFORE OK TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 250 - THEREFORE OK SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY PONT TO AN EXIT OR ENTRANCE TO NE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WiTHiN TENANT SPACE i5 LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.45.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY I -HOUR FiRE DOOR ASSEMBLY TI-1,4T IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.483. SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR 61-1ALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS TWAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL PLUMBING= REQUIREMENTS: SECTION 2W22 - SEPARATE FACILITIES 51-1ALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH MAXIMUM OCCUPANT LOAD IS 50 OR LESS. OCCUPANCY LOAD IN NEW LANDLORD STORAGE IS 2 THEREFORE SEPARATE FACILITIES IS NOT REQUIRED. TENANT iS RESPONSIBLE FOR PLUMBING REQUIREMENT W111HIN TENANT SPACE 612 PER THEIR SCOPE OF WORK General Notes 1. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.- 3. THE ARCHITECT WILL HAVE ,4 REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SiTE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. b. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT 5140W EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSDRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAM FOR SIMILAR CONDITIONS. 8. CONTRACTOR" TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER NCLUDiNG: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TiMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WOW WITH OWNER 10. ALL INTERIOR GWB IS I" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GUS. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E- 2A -108C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. lb. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBNG ITEMS PENETRATE PARTITIONS, STUDS 51-1ALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11 PROVIDE EXIT ILLUMNATICN PER LOCAL CODES. 18. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS 51-IALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK I5 TO BE SUBMITTED UNDER SEPARATE PERMITS. Scope of Work SCOPE OF WORK SHALL INCLUDED THE LANDLORD BUILD OUT OF TENANT IMPROVEMENT TO AN EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER N PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: - CONSTRUCTION OF NEW TENANT DEMISING WALL REDUCING THE SIZE OF TENANT SPACE 612 - CONSTRUCTION OF ADJACENT NEUTRAL PIER AT TENANT MALL STOREFRONT - CONSTRUCTION OF NEW STORAGE SPACE TO BE USED BY WESTFIELD MALL AT SPACE CREATED BY NEW DEMISING WALL. - ASSOCIATED DOOR, HARDWARE, LIGHTING, EGRESS PATHWAY, FIRE ALARM DETECTION AND SPRINKLER MODIFICATIONS WITHIN NEW STORAGE AREA. Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET A1.0 FLOOR PLAN AND DETAILS A2.0 ELEVATION AND DETAILS A3.0 REFLECTED CEILING PLAN Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIR= SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING Vicinity Map -___,,,§ 151th l (Ord Ave S152ndlyf y f', 1 t, IT \S 154th St 5.153rd §ts }� it I T. '� °� 'ti \Tukwila WI' • ' \• Park CryFtar Sm./rigs 'At;-1( AO! $ Evans Blacks( Baker. Blvd . 11. a StranderBlvd •5 167th St,. Tukwila Pond _ TrcckDr NORTH FILE COPY Permit No._T) tO 7Sa Pi ^i1 review approval is subject to errors and omissions. t "oval of construction documents does not authorize io!ation of any adopted code or ordinance. Receipt a; .pproved Field Copy and s acknowledged: By Date: , °2 ` b 1 . 'Z ©I 1 City Of Tlakwila BUILDING DIVISION Project Directory LEA SOUTHCENTER, LLC 2200 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER: ANDREW CIARROCHI T - 206246.0423 F - 206244.8601 MALL OPERATIONS: CHRISTIAN FALTENBERGER T - 253611.9435 F - 206244.8601 CFALTENBERGER.WESTFIELD.COM TENANT COORDINATOR: DANYULE BRAKUS T. 2068026010 F. 3106895/02 C. 213399.0959 DBRAKUS6WESTFIELD.COM ARCHITECT SM. STEMPER ARCHITECTS, PLL. C. 4000 Delridge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 - 2111 (206) 624 -2913 FAX wayne*smstemper.com SEPARATE PERMIT REQUIRED FOR: ErMechanical i"Iectrical Er3Iumbing rirGas Piping City of Tukwila BUILDING DIVISION, REVISIONS Eto r3- -• -Ipes shall be made to the scope c• . ' - ^r :( without prior approval of (jkv..f'l l Su!ildin g Division. NOTE: i' ^.1/" c:iil rL quire a new plan submittal and n mz i .; ►c :ude additional plan review fees. r Site Plan TENANT SPACE 515 SOUTHCENTER REVIEWED FOR CODECOMPf1U APPRVED ANCE S IJAN 0 6 2011 BUILDING DMON mervyrrs 2 LEVELS CITYOFTUKVNLA DEC 2 8 2010 PERMIT CENTER WeslIle[dr Southcenter 633 Sauthwnt.r Pakway TUkwla WA.. Q8168 -2666 206 - 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN MSTRUMENT OF SERNCE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INEORMARON SINN ON THE !NAMING ARE FOR USE ON THE SPEOAED PROJECT ONLY AND SHALL NOT BE USED OTHERMISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (206) 624 -2973 MPROVEMENTS ON- O w _1 O 0< Z CL < J � J z Q Q J z zQ (i) w 0 z z w F- ISSUE ISSUE PERMIT SET DATE: DEC. 28, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA #1022.20 (�1 + 15' -8 5/8" EXISTING ADJACENT TENANT SPACE + 12' -4 5/8" 50' -2" 8' -9 3 /B" 41 -4 5/8" + 3' -1" IA EXISTING BACK OF HOUSE - CORRIDOR LEASE LINE (E) TENANT DEMISING WALL TO REMAIN (E) ELECTRICAL/TELECOM liPANELS TO BE RELOCATED FOR FUTURE TENANT : ELECT. NEW CONST, (E) NO WORK IA EXISTING BACK OF HOUSE - CORRIDOR IA FLOOR PLAN (E) DOOR TO REMAIN ± 16.1-0" r li LANDLORD STORAGE AREA 101 IA 1 /4" = 1' -0" PATCH GU1B - PAINT TO LEVEL 4 FINISH FUTURE )" ALUM. REVEAL BY TENANT DEMO WALL FA ENOUGH BACK TO ALLOW FOR CONSTRUCTION OF NEW WALL RELOCATED (E) ELECTRICAL/TELECOM PANES PER FUTURE TENANT RE ELECT. 1 DEMQ WALL FAR ENOUGH BACK TO ALLOW FOR CONSTRUCTION OF NEW WALL NO WORK THIS AREA - FUTURE TENANT SPACE IA NEW CONSt, (E) NO WORK OUTLINE OF (E) BULKHEAD ABOVE DEMO (E) FMS (E) TENANT DEMISING WALL TO REMAIN LEASE LINE DEMO (E) STONE FINISH - FULL HEIGHT OF EXISTING NEUTRAL PIER DEMO (E) REVEALS - FULL HEIGHT OF EXISTING NEUTRAL PIER, TYPICAL EACH SIDE N. NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" DEMO EXISTING METAL REVEAL - TYPICAL EACH SIDE OF NEUTRAL PIER OUTLINE OF (E) BULKHEAD ABOVE DEMO (E) FMS OUTLINE OF (E) BULKHEAD ABOVE DEMO (E) FINS OUTLINE OF FUTURE STOREFRONT BY TENANT LEASE LINE 2' -6" _..J 3" 41 -4" DEMO EXISTING STONE FINISH - FULL HEIGHT OF EXISTING NEUTRAL PIER S. NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" (E) ADJACENT TENANT STOREFRONT TO REMAIN REMOVE BASE AS REQUIRED TO CONSTRUCT NEUTRAL PIER LEASE LINE OUTLINE OF FUTURE STOREFRONT BY TENANT FUTURE )6" ALUM. REVEAL BY TENANT 12" HIGH STONE BASE - AS REQUIRED AT NEUTRAL PIER GWB - PAINT TO LEVEL 4 FINISH VACANT TENANT SPACE 100 113 NO WORK THIS AREA - FUTURE TENANT SPACE IB (E) SOFFIT ABOVE TO REMAIN 1- (E) FINS AT BULKHEAD OVER DOOR TO BE DEMOLISHED PATCH AND PAINT GWB (E) DOOR TO REMAIN EXISTING ADJACENT TENANT SPACE 110 MI WALL TYPES 4 d) J 1F4 15 EXISTING WALL TYPE 2 (1 -HR RATED)UL DESIGN * U -465 - EXISTING 5/8" TYPE X GWB - METAL STUD FRAMING - 5/8" TYPE X GLOB AT TENAT SPACE - WALL SHALL CONTINUE UP TO STRUCTURE W/ GUJB STOPPING 6" FROM STRUCTURE CONTRACTOR SHALL VERIFY THE STATUS OF EXISTING WALL ASSEMBLY TO MEET MEET I -HR RATED ASSEMBLY REQUIREMENT. 2 WALL TYPE I- RATED ASSEMBLY UL 11-465 - 5/8" TYPE X GU1B - 6" METAL STUD FRAMING - 5/8" TYPE X GUS - WALL SHALL CONTINUE UP TO STRUCTURE W/ GWB STOPPING 6" FROM STRUCTURE - TYPICAL WALL TYPE GENERAL NOTES: I. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO METAL STUD WIDTH AND THICKNESS, HEIGHT OF STUD FRAMING, CONDITION OF EXISTING GLIB. 2. CONTRACTOR SHALL PREP AND PRIME ALL NEW TENANT SPACE GUS AND STORAGE AREA GUS TO LEVEL 4 FINISH. 3. CONTRACTOR SHALL PREP AND PAINT ALL MALL CONCOURSE (NEUTRAL PIERS, BULKHEAD, ETC., RELATED AREAS TO LEVEL 4 FINISH. COLOR TO BE DETERMINED BY WESTFIELD. 4. CONTRACTOR SHALL MAINTAIN RATING OF ALL I -HOUR RATED ASSEMBLIES - EXISTING AND NEW ASSEMBLIES WITHIN AREA OF WORK ■ (E) FINS AT BULKHEAD TO BE DEMOLISHED (E) STOREFRONT TO REMAIN LEASE LINE TYPICAL FLOOR PLAN GENERAL NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL COORDINATE WITH LANDLORD REGARDING EXISTING CONDITIONS, AND SERVICES TO NEW LANDLORD STORAGE AREA. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MIN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL/MECHANICAL ARE SHOWN FOR REFERENCE ONLY. DATA, ELECTRICAL, AND MECHANICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SF'READ OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) b. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRICTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. 8. CONTRACTOR SHALL PRIME ALL NEWLY CONSTRUCTED WALLS, NEUTRAL PIERS, SOFFITS, AND BULKHEADS TO LEVEL 4 FINISH. NEUTRAL PIER AND MALL CONCOURSE AREAS TO BE PAINTED TO LEVEL 4 FINISH. 9. AREAS DESIGNATED AS '(E) NO WORK' AND 'NO WORK / FUTURE TENANT SPACE' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AND NEW LANDLORD STORAGE AREA AS REQUIRED. 10. CONTRACTOR 51-IALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED, AT FINISH FLOOR LEVEL FOR ALL SERVICES AND UTILITIES WITHIN THE FLOOR SLAB. 11. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS POINT OF ORIGIN. 12. CONTRACTOR SHALL PROVIDE REQUIRED MECHANICAL (HVAC) AND ELECTRICAL SERVICE TO NEW STORAGE AREA UNDER SEPARATE PERMIT. SERVICES SHALL BE CONNECTED BACK TO LANDLORD UTILITIES. 13. CONTRACTOR SHALL PROVIDE AT A MINIMUM (UNDER SEPARATE PER"IIT), TWO POWER OUTLETS FOR THE NEW LANDLORD STORAGE AREA, ONE ALONG THE NORTH WALL ONE ALONG THE SOUTH WALL, OR AS REQUIRED BY ELECTRICAL CODE. O FLOOR PLAN KEY NOTES: 01 (E) WALL MOUNTED LAVATORY TO SE DEMOLISHED IN ITS ENTIRETY INCLUDING PIPING, AND WASTE LINES. CAP WATER AND WASTE LINES BELOW FINISH FLOOR LEVEL TO ALLOW UNIFORM AND LEVEL CONCRETE PATCHING OF FLOOR. 02 (E) WATER CLOSET TO BE DEMOLISHED M ITS ENTIRETY INCLUDING BUT NOT LIMITED FLOOR TO, WATER SUPPLY AND WASTE LINES. CAP WATER AND WASTE LINE BELOW FINISI -I FLOOR LEVEL TO ALLOW UNIFORM AND LEVEL CONCRETE PATCHING OF 03 (E) METAL STUD FRAMING AND GUJB WALL ASSEMBLY TO BE DEMOLISHED IN ITS ENTIRETY, FROM SLAB TO STRUCTURE. DEMOLITION OF WALL ASSEMBLY SHALL INCLUDE BUT NOT BE LIMITED TO, STUD BOTTOM AND TOP TRACK, METAL STUD FRAMING, GU I3, WALL FIXTURES, ELECTRICAL, DATA, AND MECHANICAL FIXTURES /SERVICES. 04 (E) HOLLOW METAL FRAME AND DOOR TO BE BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, FRAME, DOOR, HARDWARE AND THRESHHOLD. 05 (E) COLUMN COVER TO REMAIN 06 (E) WALL ASSEMBLY TO REMAIN 0 (E) WALL ASSEMBLY/READER TO REMAIN 08 (E) FLOOR FINISH TO BE DEMOLISHED DOM TO EXISTING CONCRETE SLAB. PN sEP 18 2011 t:lo3S' REVIEWED FOR CODE COMPLIANCE APPPOVED JAN 0 6 2011 CityotTukwila BUILDING DIVISION RECEIV�p CITYOFiUK{MLA DEC 2 8 2010 PERMIT CENTER ■ Westfleki Sou th cen ter 633 Sauthantar Parkway TUkda• WA., 98t88 -2088 206 - 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 MIS DRAWING IS AN INSTRUMENT CF SERVICE, IS ME PROPERTY OF ME ARCHITECT AND MAY NOT BE REPRODUCED YAMOUT ME ARCHITECT'S PERMISSION AND UNLESS ME REPRODUCTION CARRIES THE ARCHITECT'S NAME, ALL DESGN AND OTHER INFORMATION SHOWN ON THE ORAVANG ARE FCR USE ON ME SPECIFlEO PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (200) 624 -2973 MPROVEMENTS ISSUE J J < 00 Ct 070 w Q w U Q O� Lo D r 0 L ISSUE PERMIT SET DATE: DEC. 28, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN DETAILS A1.0 SMSA #1022.20 1 1 1 / 2' -6" _..J 3" 41 -4" DEMO EXISTING STONE FINISH - FULL HEIGHT OF EXISTING NEUTRAL PIER S. NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" (E) ADJACENT TENANT STOREFRONT TO REMAIN REMOVE BASE AS REQUIRED TO CONSTRUCT NEUTRAL PIER LEASE LINE OUTLINE OF FUTURE STOREFRONT BY TENANT FUTURE )6" ALUM. REVEAL BY TENANT 12" HIGH STONE BASE - AS REQUIRED AT NEUTRAL PIER GWB - PAINT TO LEVEL 4 FINISH VACANT TENANT SPACE 100 113 NO WORK THIS AREA - FUTURE TENANT SPACE IB (E) SOFFIT ABOVE TO REMAIN 1- (E) FINS AT BULKHEAD OVER DOOR TO BE DEMOLISHED PATCH AND PAINT GWB (E) DOOR TO REMAIN EXISTING ADJACENT TENANT SPACE 110 MI WALL TYPES 4 d) J 1F4 15 EXISTING WALL TYPE 2 (1 -HR RATED)UL DESIGN * U -465 - EXISTING 5/8" TYPE X GWB - METAL STUD FRAMING - 5/8" TYPE X GLOB AT TENAT SPACE - WALL SHALL CONTINUE UP TO STRUCTURE W/ GUJB STOPPING 6" FROM STRUCTURE CONTRACTOR SHALL VERIFY THE STATUS OF EXISTING WALL ASSEMBLY TO MEET MEET I -HR RATED ASSEMBLY REQUIREMENT. 2 WALL TYPE I- RATED ASSEMBLY UL 11-465 - 5/8" TYPE X GU1B - 6" METAL STUD FRAMING - 5/8" TYPE X GUS - WALL SHALL CONTINUE UP TO STRUCTURE W/ GWB STOPPING 6" FROM STRUCTURE - TYPICAL WALL TYPE GENERAL NOTES: I. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO METAL STUD WIDTH AND THICKNESS, HEIGHT OF STUD FRAMING, CONDITION OF EXISTING GLIB. 2. CONTRACTOR SHALL PREP AND PRIME ALL NEW TENANT SPACE GUS AND STORAGE AREA GUS TO LEVEL 4 FINISH. 3. CONTRACTOR SHALL PREP AND PAINT ALL MALL CONCOURSE (NEUTRAL PIERS, BULKHEAD, ETC., RELATED AREAS TO LEVEL 4 FINISH. COLOR TO BE DETERMINED BY WESTFIELD. 4. CONTRACTOR SHALL MAINTAIN RATING OF ALL I -HOUR RATED ASSEMBLIES - EXISTING AND NEW ASSEMBLIES WITHIN AREA OF WORK ■ (E) FINS AT BULKHEAD TO BE DEMOLISHED (E) STOREFRONT TO REMAIN LEASE LINE TYPICAL FLOOR PLAN GENERAL NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL COORDINATE WITH LANDLORD REGARDING EXISTING CONDITIONS, AND SERVICES TO NEW LANDLORD STORAGE AREA. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MIN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL/MECHANICAL ARE SHOWN FOR REFERENCE ONLY. DATA, ELECTRICAL, AND MECHANICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SF'READ OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDANT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) b. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 1. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRICTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. 8. CONTRACTOR SHALL PRIME ALL NEWLY CONSTRUCTED WALLS, NEUTRAL PIERS, SOFFITS, AND BULKHEADS TO LEVEL 4 FINISH. NEUTRAL PIER AND MALL CONCOURSE AREAS TO BE PAINTED TO LEVEL 4 FINISH. 9. AREAS DESIGNATED AS '(E) NO WORK' AND 'NO WORK / FUTURE TENANT SPACE' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AND NEW LANDLORD STORAGE AREA AS REQUIRED. 10. CONTRACTOR 51-IALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED, AT FINISH FLOOR LEVEL FOR ALL SERVICES AND UTILITIES WITHIN THE FLOOR SLAB. 11. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS POINT OF ORIGIN. 12. CONTRACTOR SHALL PROVIDE REQUIRED MECHANICAL (HVAC) AND ELECTRICAL SERVICE TO NEW STORAGE AREA UNDER SEPARATE PERMIT. SERVICES SHALL BE CONNECTED BACK TO LANDLORD UTILITIES. 13. CONTRACTOR SHALL PROVIDE AT A MINIMUM (UNDER SEPARATE PER"IIT), TWO POWER OUTLETS FOR THE NEW LANDLORD STORAGE AREA, ONE ALONG THE NORTH WALL ONE ALONG THE SOUTH WALL, OR AS REQUIRED BY ELECTRICAL CODE. O FLOOR PLAN KEY NOTES: 01 (E) WALL MOUNTED LAVATORY TO SE DEMOLISHED IN ITS ENTIRETY INCLUDING PIPING, AND WASTE LINES. CAP WATER AND WASTE LINES BELOW FINISH FLOOR LEVEL TO ALLOW UNIFORM AND LEVEL CONCRETE PATCHING OF FLOOR. 02 (E) WATER CLOSET TO BE DEMOLISHED M ITS ENTIRETY INCLUDING BUT NOT LIMITED FLOOR TO, WATER SUPPLY AND WASTE LINES. CAP WATER AND WASTE LINE BELOW FINISI -I FLOOR LEVEL TO ALLOW UNIFORM AND LEVEL CONCRETE PATCHING OF 03 (E) METAL STUD FRAMING AND GUJB WALL ASSEMBLY TO BE DEMOLISHED IN ITS ENTIRETY, FROM SLAB TO STRUCTURE. DEMOLITION OF WALL ASSEMBLY SHALL INCLUDE BUT NOT BE LIMITED TO, STUD BOTTOM AND TOP TRACK, METAL STUD FRAMING, GU I3, WALL FIXTURES, ELECTRICAL, DATA, AND MECHANICAL FIXTURES /SERVICES. 04 (E) HOLLOW METAL FRAME AND DOOR TO BE BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO, FRAME, DOOR, HARDWARE AND THRESHHOLD. 05 (E) COLUMN COVER TO REMAIN 06 (E) WALL ASSEMBLY TO REMAIN 0 (E) WALL ASSEMBLY/READER TO REMAIN 08 (E) FLOOR FINISH TO BE DEMOLISHED DOM TO EXISTING CONCRETE SLAB. PN sEP 18 2011 t:lo3S' REVIEWED FOR CODE COMPLIANCE APPPOVED JAN 0 6 2011 CityotTukwila BUILDING DIVISION RECEIV�p CITYOFiUK{MLA DEC 2 8 2010 PERMIT CENTER ■ Westfleki Sou th cen ter 633 Sauthantar Parkway TUkda• WA., 98t88 -2088 206 - 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 MIS DRAWING IS AN INSTRUMENT CF SERVICE, IS ME PROPERTY OF ME ARCHITECT AND MAY NOT BE REPRODUCED YAMOUT ME ARCHITECT'S PERMISSION AND UNLESS ME REPRODUCTION CARRIES THE ARCHITECT'S NAME, ALL DESGN AND OTHER INFORMATION SHOWN ON THE ORAVANG ARE FCR USE ON ME SPECIFlEO PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (200) 624 -2973 MPROVEMENTS ISSUE J J < 00 Ct 070 w Q w U Q O� Lo D r 0 L ISSUE PERMIT SET DATE: DEC. 28, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN DETAILS A1.0 SMSA #1022.20 DEMO (E) TRIM AS REQUIRED TO CONSTRUCT NEUTRAL PIER - REINSTALL AND PAINT TO MATCH EXISTING CONDITION TOP OF BULKHEAD 151 -6011 TOP OF STOREFRONT 14 -01111 BOTTOM OF MULLION 10' -0" METAL STUD FRAMING AND GM NEUTRAL PIER - PAINT TO LEVEL 4 FINISH. ADJACENT TENANT STOREFRONT TO REMAIN 1/2" ALUM. REVEAL EACH SIDE OF NEUTRAL PIER - TYPICAL 4) FINISH FLOOR 01 -0" (E) WOOD FINS TO BE DEMOLISHED ABOVE STOREFRONT AND NEUTRAL PIER PATCH AND PAINT GUS (LEVEL 4 FINISH) PER WESTFIELD (E) WOOD FINS TO BE DEMOLISHED ABOVE DOOR AND NEUTRAL PIER PATCH AND PAINT GWS (LEVEL 4 FINISH) PER WESTFIELD ------------ ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING \ HDWR GROUP A` -- HEAD JAMB �Y'mYm • 1:111 ill ,Ali`AAI%AAAA W YYm ' YYYYYYYYYYYY' m YYYYYYYYYYYY 'YYYYYYYYYY'YY'YYYYYYI 1 1 1 1 1 1 ill 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I Ill 1 1 1 1 1 V I I I Ill 1 I I 1 1 1 I 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 IAAAA AA% LA AAA AAAA AAA AIAAAAA AAA AA,LAAA%%A%%i v W w W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W YYYYYYYYYYYYYYYYY 'YYYYYYYYYYYYYYYYY'.YYYY 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 I I 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 % AA%% AA %A%%%%%A%%Ih%%%%AA%%%%%%%AAAIAA W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 1' t A .1 1 l,r'I •I1 1 W \ A A A A A A A A A m A YYYYYYYY� 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 1 I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 AAAAAAAAAA W W W W W W W W W W W )./N ��\A, AA, `� (E) TENANT BULKHEAD TO REMAIN - TYPICAL (E) PANELS TO REMAIN TYPICAL (E) TENANT BULKHEAD TO REMAIN - TYPICAL (E) TENANT SIGNAGE AND ENTRY TO REMAINL / / / I- / ADJACENT TENANT STOREFRONT TO REMAIN DEMO (E) TRIM AS REQUIRED TO CONSTRUCT NEUTRAL PIER - REINSTALL AND PAINT TO MATCH EXISTING CONDITION STOREFRONT ELEVATION 1/2" = 1' -0" ,4)TOP OF STOREFRONT 1 151 -61111 LEASE LINE I TOP OF STOREFRONT 14' -0011 (E) BULKHEAD AND TENANT STOREFRONT TO REMAIN (E) GLASS STOREFRONT TO REMAIN DEMO (E) FINS AT TENANT STOREFRONT AND NEUTRAL PIERS 12" HIGH STONE TILE BASE - OFCI (E) TENANT STOREFRONT TO REMAIN (E) BULKHEAD NEUTRAL PIER BEYOND PAINT - LEVEL 4 FINISH ALL SIDES 0 I 0 0 (E) BULKHEAD DETAIL 1 1 /2" = 11 -0" L(E) PAIR OF GLASS ENTRY DOORS TO REMAIN (E) TENANT STOREFRONT TO REMAIN 12" HIGH STONE TILE BASE - OFCI (E) STONE TO BE REMOVED PATCH AND PAINT NEUTRAL - COLOR TO MATCH ADJACENT MALL CONCOURSE (E) GWS SOFFIT AT ALCOVE TO REMAIN DEMO (E) REVEALS (2) AND INSTALL NEW 1/2" ALUM. REVEAL EACH SIDE OF NEUTRAL PIER - TYPICAL (E) DOOR AT CORRIDOR TO REMAIN DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB THRESH 100 MALL CONCOURSE - CORRIDOR FLUSH WOOD 31 -0" x 10' -0" 1 3/4" WOOD N/A HM I HR -- -- -- -- I 101 CORRIDOR - LANDLORD STORAGE FLUSH EXISTING 31 -0" x 1 -0" 1 3/4" HM N/A HM 1 HR -- -- - -- 1 2,3 102 TENANT SPACE - MALL CONCOURSE GLASS EXISTING PR. 3' -0" x 10' -0" 1/2" GLASS N/A N/A N.R. -- - -- 1 31 -0 "x-11 -00 NOTES HARDWARE GROUPS ABBREVIATIONS 1. EXISTING DOOR TO REMAIN - NO MODIFICATIONS TO DOOR, FRAME, OR HARDWARE. 2. EXISTING DOOR TO REMAIN - CONTRACTOR SHALL REPLACE LOCKSET PER WESTFIELD REQUIREMENTS. FUNCTION SHALL ALLOW EXIT ALWAYS FROM INTERIOR OF STORAGE AREA AND LOCKS FROM CORRIDOR. 3. EXISTING DOOR AND FRAME TO BE PAINTED -COLOR TO BE SELECTED BY WESTFIELD. GROUP 1 - HOLLOW METAL DOOR L- SERIES AL ALUMINUM FL FLUSH DOOR FR FRAME 1-IM HOLLOW METAL NR NON -RATED STOR STOREFRONT WD WOOD 1 - LEVER TYPE HANDLES - MANUFACTURER: , 11 LEVER HANDLE, SATIN CHROME 1- MORTISE CYLINDER - PRIVACY FUNCTION XPI SEP 3 8 2011 Duo -3s� CODE REVIEWED FOR COMPLIANCE APPRnVFD JAN 0 6 2011 City cTuktIa BUILDING DIVISION cm( OF DEC 2 8 2010 PERMIT CENTER WeslIle[c[ Southcenter 633 Southo.nt.r Parkway 'Marla, WA., 98188 -2888 208- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS ORATING IS All INSTRUMENT CF SERVICE, IS THE PROPERTY OF ME ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECrS PERMISSION AND UNLESS ME REPRODUCTION CARRIES THE ARCHITECT'S NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE ORATING ARE FOR USE ON ME SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT ■ S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SAP SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 MPROVEMENTS � ti w D Q Z a- < U) J � J Q Q Z F— H Z Q Cn W D Z Z W ISSUE ISSUE PERMIT SET DATE: DEC. 28, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ ELEVATION WALL SECTION AND DETAILS A2.0 SMSA #1022.20 ,0: + 15' -8 5/8" EXISTING ADJACENT TENANT SPACE + 12' -4 5/811 1 , ▪ 3' -111 EXISTING SACK OF HOUSE - CORRIDOR —(E) EXIT LIGHT TO REMAIN NEW CONST. (E) NO RK 1 L I 11 J 16' -0" 4 ST ABRG X -102 ACT +/- 9' -0" J 1 I\� 04 1 I \ 1 1 1 I �\ 1 I 1 R 5Tl . • I L- IX -103L 1 , +/- 9' -0" L 1 L r I I j EXISTING 1 EXISTING BACK OF HOUSE - CORRIDOR - - -) I- - I- - - - I CORRIDOR I' - -- -H- -I- - -- 11 1 -- — 1-- J - - -T- I -i -1 e"i \I / X -I0 �\ ACT IL I J — I- - --I - - -± ' ---- r--- 1--- -I--- T - - -T -- - -T -- 1 J EXISTING X -104 ACT I 1 +1 -- 9' -0i1 +- -1 01 EXIaTING __PI4OTC9 ROOM Ix-i0 I +1- W-0" X O 0I 04 NEW CONST f (E) NO WORK EXISTING /DEMO REFLECTED CEILING PLAN 1 /4" = 1' -0" ± 12'- 45/8" 9 +1 EXISTING SACK OF HORSE - CORRITOR + 31_1" EXISTING BACK OF HOUSE - CORRIDOR NEW CONST. (E) NO AI (E) EXIT LIGHT TO REMAIN MECH. DIFFUSER " AS REQUIRED RE: MECHANICAL 41 -011 STRIP LIGHT RE: ELECTRICAL LANDLORD STORAGE AREA 41 -0" STRIP -V LIGHT RE: ELECTRICAL 101 MECH. DIFFUSER 1 AS REQUIRED RE: MECHANICAL 41 -011 STRIP-' LIGHT RE: ELECTRICAL 41 J 04 11 E31, 1 I/ EXISTING ADJACENT TENANT SPACE CONTRACTOR SHALL BRACE /CONNECT EXISTING CEILING GRID AND TILE AT LINE OF DEMOLITION - TYPICAL (E)2X2 LAY IN LIGHT FIXTURES TO REMAIN RE: ELECTRICAL - TYPICAL NEW DEMISING WALL. PER PLAN /— PARTIAL REFLECTED CEILING PLAN 2 1/4 =1 -0 NEW CONST. (E) NO WORK 16' -0" EXISTING ADJACENT ADJACENT TENANT SPACE (E) MECHANICAL DIFFUSERS TO REMAIN RE: MECHANICAL TYPICAL FUTURE TENANT SPACE - EXISTING CEILING, LIGHTING, SPRINKLERS, FINISHES, MECHANICAL AND ELECTRICAL SYSTEMS TO REMAIN FOR FUTURE WORK BY TENANT (E)2X2 LAY IN LIGHT FIXTURES TO REMAIN RE: ELECTRICAL - TYPICAL LEASE LINE TYPICAL FUTURE TENANT SPACE - EXISTING CEILING, LIGHTING, SPRINKLERS, FINISHES, MECHANICAL AND ELECTRICAL SYSTEMS TO REMAIN FOR FUTURE WORK BY TENANT NOTE: PARTIAL REFLECTED CEILING PLAN IS SHOWN FOR CLARITY REGARDING THE NEW CONSTRUCTION AND CEILING LAYOUT FOR THE NEW LANDLORD STORAGE AREA, AND TENANT DEMISING WALL. h (E) FINS AT BULKHEAD OVER DOOR TO BE DEMOL ISHED PATCH AND PAINT GWB (E) GWB SOFFIT AT TO REMAIN (E) FINS AT BULKHEAD TO BE DEMOLISHED (E) STOREFRONT TO REMAIN LEASE LINE TYPICAL (E) FINS TO BE DEMOLISHED AT BULKHEAD - ABOVE TENANT SPACE, NEUTRAL PIER AND DOOR REFLECTED CE IL INCA PLAN GENERAL NOTES: I. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL SEISMICALLY BRACE SUSPENDED CEILING GRID SYSTEM PER LOCAL JURISDICTIONAL REQUIREMENTS. 3. LIGHTING IS SWOON FOR REFERENCE ONLY AS ELECTRICAL IS DESIGN BUILD BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WIN DESIGN BUILD LIGHTING PLANS AND WESTFIELD THROUGHOUT CONSTRUCTION. 4. MECHANICAL DIFFUSERS ARE SHOUN FOR REFERENCE ONLY AS MECHANICAL IS DESIGN BUILD BY CONTRACTOR CONTRACTOR SHALL COORDINATE WITH DESIGN BUILD MECHANICAL PLANS AND WESTFIED THROUGHOUT CONSTRUCTION. 5. EGRESS PATHWAY LIGHTING SHALL BE PROVIDED AS REQUIRED FOR NEW LANDLORD STORAGE AREA AND VACANT SPACE PER REQUIREMENTS SET FORTH BY LOCAL JURISDICTION. 6. CONTRACTOR SHALL SUPPORT AND BRACE ANY AND ALL CEILING COMPONENTS AT LINE OF DEMOLITION, INCLUDING BUT NOT LIMITED TO SUSPENDED CEILING GRID AND TILE, DUCTWORK, CONDUIT AND WIRING. 1. AREAS DESIGNATED AS '(E) NO WORK' AND 'NO WORK / FUTURE TENANT SPACE' SHALL REMAIN AS CURRENT CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET FORTH BY LOCAL JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE ALARM SHALL PROVIDE COVERAGE FOR THE VACANT SPACE AS REQUIRED. 8. CONTRACTOR SHALL CAP AND TERMINATE ALL EXISTING UTILITIES AND SERVICES DESIGNATED TO BE DEMOLISHED ABOVE FINISH FLOOR LEVEL AT ITS POINT OF ORIGIN. 9. CONTRACTOR SHALL PROVIDE REQUIRED HEATING AND CONDITIONING OF NEW STORAGE SPACE AS REQUIRED BY LOCAL JURISDICTION SEPARATE FROM VACANT TENANT SPACE AND CONNECTED TO MALL SERVICE. REFER TO DESIGN BUILD MECHANICAL. 10. CONTRACTOR SHALL PROVIDE REQUIRED SPRINKLER AND FIRE ALARM PROTECTION WITHIN VACANT TENANT SPACE AS REQUIRED BY LOCAL JURISDICTION. 11. LIGHTING AND MECHANICAL LAYOUTS ARE SHOUI4 FOR REFERENCE ONLY, EXACT QUANTITIES FOR DEMOLITION SHALL BE FIELD VERIFIED AND CONFIRi1ED PRIOR TO CONSTRUCTION. 12. LIGHTING FOR NEW STORAGE AREA SHALL INCLUDE OCCUPANCY SENSOR RE: ELECTRICAL - SUBMITTED UNDER SEPARATE PERMIT. REFLECTED GEILINCz PLAN KEY NOTES: (E) CEILING TILE AND GRID TO REMAIN, INCLUDING BUT NOT LIMITED TO, ALL ASSOCIATED LIGHTING, MECHANICAL SYSTEMS, SPRINKLER SYSTEMS, GWB SOFFITS, GUJB HEADERS, AND SPEAKERS. (E) CEILING TILE AND GRID TO BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO RUNNERS, GUY WIRE, ANCHORS, SEISMIC BRACING, AND CEILING MOUNTED FIXTURES LIGHTING. (E) LIGHTING TO BE DEMOLISHED IN ITS ENTIRETY INCLUDING BUT NOT LIMITED TO LIGHT FIXTURE, LAMPS, BALLASTS, CONDUIT AND WIRING. ALL CONDUIT AND WIRING SHALL BE TERMINATED AT PONT OF ORIGIN JUNCTION BOX. (E) MECHANICAL SUPPLY AND /OR RETURN DIFFUSER TO BE DEMOLISHED IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO DIFFUSER, DUCTWORK, INSULATION, DAMPERS, ELECTRICAL ASSOCIATED WITH DESIGNATED DIFFUSERS. DUCTWORK SHALL BE TERMINATED AT POINT OF ORIGIN. SEP 1 8.2011 --REVIEWED FOR CODE COMPLIANCE APPMWED JAN 06 2011 City of Tukwila BUILDING DIVISION btost FEU�CI OTU DEC 2 8 2010 PERMITCEP6'FER ■ WeslIle[d Southcenter 633 Southard"? Parkway TUkda, WA., 96188 -2888 206 - 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS CRANING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF ME ARCHITECT AND MAY NOT BE REPRODUCED WTHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRCOUCRON CARF ES THE ARCHITECTS NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWNG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND 91ALL NOT BE USE0 OTHERMSE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 624 -2973 Ct W Z W co co 0 CD4C U-1 U 2 Z J r C� o Q w rn Z Q Q C(2 w� < ¢w OY D z¢�~ W w C� ~ W z ISSUE ISSUE DATE: PERMIT SET DEC. 28, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ SCHEDULES AND DETAILS A3.0 SMSA #1022.20