HomeMy WebLinkAboutPermit D11-001 - ANGRY SQUID INK - ROOFANGRY SQUID INK
5219 S 144 ST
EXPIRED
07-06-11
Dl 1 -001
Parcel No.:
Address:
Suite No:
Project Name:
City ATukwila
M
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
7999600066
5219 S 144 ST TUKW
ANGRY SQUID INK
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D11 -001
01/05/2011
07/04/2011
Owner:
Name: KISSINGER R & T TRUST U/A
Address: KISSINGER R & T TRUSTEES , 14415 53RD AVE S 98168
Contact Person:
Name: RICHARD BOMARS
Address: 1551 127 PL NE , BELLEVUE WA 98005
Contractor:
Name: CERTIFIED CONTRACTORS INC
Address: 1551 127 PL NE , BELLEVUE WA 98005
Contractor License No: CERTICIO32L5
Phone: 206 349 -1732
Phone: 425 - 646 -9441
Expiration Date: 02/14/2011
DESCRIPTION OF WORK:
INSTALL +95 FIRESTONE ISOCYANURATE INSLUATOIN OVER EXISTING 2 -PLY MODIFIED ROOF OVER PLYWOOD.
INSTALL .60 MIL TPO ROOFING SYSTEM OVER INSULATION TO BE MECHANICALLY ATTACHED. INSTALL NEW 26
GAUGE COPING CAP, (5) NEW THRU WALL SCUPPERS TO BE CLAD TPO WELD METAL, AND (2) ADDITIONAL
DOWNSPOUTS.
Value of Construction:
Type of Fire Protection:
Type of Construction:
$22,240.00
Fees Collected:
International Building Code Edition:
Occupancy per IBC:
$1,401.32
2009
0011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
N
Number: 0 Size (Inches): 0
N Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Water Main Extension:
Water Meter: N
Start Time: End Time:
Private:
Profit: N
Private:
Public:
Non - Profit: N
Public:
doc: IBC -7/10
D11 -001
Printed: 01 -05 -2011
Permit Center Authorized Signature:
•
•
Date: U�5
I hereby certify that I have read and ned this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie whether specified herein or not.
The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name: bA L L.
Date: / ✓ ' //
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate
shall be provided to the building inspector.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11-001 Printed: 01 -05 -2011
CITY OFT ' A
Community D( , ment Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building POt No.
17 l ^ 001
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No. 6i1tJ 0 —
Site Address: 5a, G} S 14 4A-Nr154 - ItAKUAIVA
ION a8 14 a Suite Number: Floor:
Tenant Name: As C rfu ti- .T ?A New Tenant: ❑ Yes
Property Owners Name: ..--Rcx\ ph k \ S S \ ru je Y-
Mailing Address: 42i 5 3 iAvE
Vg No
rua(%ki m; WA- 58140
City State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: rr. XX
Mailing Address: 1551 i 2`l tom` P1 N& 1e1k ue
E -Mail Address: l n co 0 ee 4 c \eck ehvytracitors live Q.O YYk
Day Telephone: 24(6 3 4 9 -/ 7 3
wf 9 ?dos
City State Zip
Fax Number: •44.5 45 / 3 9611
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: Ce4 - 06-y- .,+ro( -ors Tti�1G
Mailing Address: \ 5l \ -1 PI N4 /4 de i/Of t,
Contact Person: e-11CI( CCU
E -Mail Address: Sctvv t..
Contractor Registration Number: GEier let D3 2 L5
in/A- q was
City
State Zip
Day Telephone: irla 5 - r!o 4.10 -q(411/
Fax Number: if 9 5 - 4L5 / — 3 gal-4
Expiration Date: 1' 1 'i_o 1
ARCHITECT OF RECORD - All plans must be stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
State
Zip
ENGINEER OF RECORD - All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application doe
Revised: 7 -2010
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION — 206 - 431 -3670
Valuation of Project (contractor's bid price $ a a, a40 • DU Existing Buin Valuation: $
Scope of Work (please provide detailed information): ,C1d21 7_ - -t+ -- �s-c
6 41-vW-- )..6-04°
Will there be new rack storage? 0 ....Yes
❑ ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ... None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building?
❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H,'Applications\Forms- Applications On Line'2010 Applications17 -2010 - Permit Application doc
Revised: 7 -2010
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
tad Floor
3rd Floor
/ V
A
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ... None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building?
❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H,'Applications\Forms- Applications On Line'2010 Applications17 -2010 - Permit Application doc
Revised: 7 -2010
bh
Page 2 of 6
X
PERMIT APPLICATION NOTES — Apible to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO,IAPPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED A ENT: f
Signature: Date: / 3- / /
Print Name: R,c.hCt rd 1 Fpm &.'r S Day Telephone: 20 C i 2(7- /7,32-
Mailing Address: t S$ 1 121 }" Pi 1116i .de l /ei'w / WA- 9 S c S
City
IDate Application Accepted:
DaD9'
Date Application Expires:
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
State
Staff Initials:
Zip
dr-Nil
Page 6 of 6
•
�J�`N��A wq� City of Tukwila
C O
1908
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 7999600066
Address: 5219 S 144 ST TUKW
Suite No:
Applicant: ANGRY SQUID INK
RECEIPT
Permit Number: D11 -001
Status: APPROVED
Applied Date: 01/03/2011
Issue Date:
Receipt No.: R11 -00012
Payment Amount: $1,058.70
Initials: JEM Payment Date: 01/05/2011 10:55 AM
User ID: 1165 Balance: $0.00
Payee: CERTIFIED CONTRACTORS, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24574 1,058.70
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
STATE BUILDING SURCHARGE
000.322.100
640.237.114
Total: $1,058.70
1,054.20
4.50
doc: Receipt -06 Printed: 01 -05 -2011
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 7999600066
Address: 5219 S 144 ST TUKW
Suite No:
Applicant: ANGRY SQUID INK
RECEIPT
Permit Number: D11 -001
Status: PENDING
Applied Date: 01/03/2011
Issue Date:
Receipt No.: R11 -00005
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $342.62
Payment Date: 01/03/2011 04:45 PM
Balance: $1,058.70
CERTIFIED CONTRACTORS, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24555 342.62
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 342.62
Total: $342.62
doc: Receiot -06 Printed: 01 -03 -2011
-41
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
•
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
1/40/1-°6
t:
end) Projec 9
kType
ofpspection: A
fcet o 0 F.
Address:
.-512-4
DA,Calilee_Mout........01) Ait
Special Instructions: ,
.
.
7 .._ _
bate Wanted: .-- --
. ( — r7 ( f . *--11Ii.p.m.
Requester:
Phone No:
Epproved vi
A *applicable codes.. 1:1Corrections required prior to approval.
.. r
COMMENTS:
.•
•
• 4'
:
: . •
'Pt
Ins Date: 1
.•
...- f
REINSPECTION V
. n - N
FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
--aux : • ..
•
. :"
0
1
0
LU E.
.1;r7 rj-Eilan.
tu
13.1 !]C
Et,
•
1
•
•
•
2
6
Certified Contractors Inc.
1551 127th Place NE, Bellevue, WA 98005
(425) 451 -3904 (Fax)
1 (888) 206 -3676 (Toll Free)
www.Roofforlife.com
Scope of work
Date: 1 -3 -11
Customer: Ralph Kissinger
Project: 5219 S 144th
Seattle WA 86168
CODE REVIEWED FOR
PLIANCE
ADDINWRID
JAN 04 Lull
Scope of Work: 1 C AA'� Tubs%
1. Existing 2 ply Modified Roof over plywood to remain. 8UILDI G nwIgIfl
2. Install +95 Firestone Isocyanurate insulation at a rate of '/4" per foot to be
mechanically attached at the rate of 5- 3" plates with #14 standard deck fasteners
per 4' X 8' sheet.
3. Install .60 Mil T.P.O. roofing system over Insulation. To be mechanically
attached at with 2 3/8" locking seam plate and #14 standard deck fasteners at the
rate of 1 per 12 ".
4. Install new 26 gauge coping cap per SMACNA guidelines.
5. Install 5 new thru wall scuppers to be clad TPO weld metal and installed to
SMACNA guidelines.
arfiONILA
JAN. 03 2011
PERMIT CENTER
p oOI
TECHNICAL INFORMATION SHEET
1105
08/01/2009
t o e
BUILDING PRODUCTS
MB 2" Barbed
Metal Lap Plate
Firestone Item Number: W56RAC4183
DESCRIPTION:
The Firestone MB 2" (51 mm) Barbed Metal Lap Plates
are specifically designed to be used as seam plates for
attachment of specific Firestone Modified Bitumen Base
Ply membrane to the approved substrate. Firestone MB
2" Barbed Metal Lap Plates are suitable for use with
Firestone Fasteners into a variety of decking materials.
METHOD OF APPLICATION:
Position Firestone MB 2" Barbed Metal Lap Plate within
seam area as specified by Firestone Asphalt
specifications. Attach Firestone MB 2" Barbed Metal Lap
Plate through the Firestone Base Sheet membrane to
roof deck substrate using a Firestone Fastener. Orient
and install the barbed plate with the barbs penetrating the
membrane and with the ribbed side up, showing the
"Firestone" name on the plate. Immediately heat -weld
the lap.
PRECAUTIONARY DATA:
• Do not overdrive or underdrive fastener.
• Firestone MB 2" Barbed Metal Lap Plates are
designed to anchor the Firestone Modified Bitumen
membrane system.
• Avoid field seams directly over insulation plates.
This sheet is meant to highlight Firestone's products and specifications and is subject to
change without notice. Firestone takes responsibility for fumishing quality materials,
which meet Firestone's published product specifications. Neither Firestone nor its
representatives practice architecture. Firestone offers no opinion on and expressly
disclaims any responsibility for the soundness of any structure. Firestone accepts no
liability for structural failure or resultant damages. Consult a competent structural
engineer prior to installation if the structural soundness or structural ability to properly
support a planned installation is in question. No Firestone representative is authorized to
vary this disclaimer.
PRODUCT DATA
Properties
Material:
Material Thickness:
Diameter:
Corrosion Resistance:
Pull Through Resistance:
Minimum Performance
Galvalumee - Sheet Steel —
AZ55
35 mil (0.9 mm)
2" (50.8 mm)
Meets FM 4470 criteria
400 Ibf (178 daN) from center
hole
Ga/valume® is a registered trademark of BIEC International Inc.
STORAGE:
Store in original unopened containers protected from the
weather.
PACKAGING:
Pail: 1000 plates
Weight: 34 lb (15.5 kg) /pail
Pallet: 40 pails
LEED INFORMATION:
Post Consumer Recycled Content:
Post Industrial Recycled Content:
Manufacturing Location:
APPROVED
8%
17%
Cleveland, OH
Firestone Building Products Company
250 W. 96"' Street, Indianapolis, IN 46260
Sales: (800) 428 -4442 • Technical (800) 428-4511
www.firestonebpco.com
S723 -RFS -098
TECHNICAL INFORMATION SHEET
1106
10/22/2009
F'reston
BUILDING PRODUCTS
Insulation Fastening Plate
Firestone Item Number: W56RAC4190
DESCRIPTION:
Firestone Insulation Fastening Plates are specially
designed to be used with Firestone All- Purpose, Heavy -
Duty, Concrete Drive and Stainless Steel Fasteners in
roofing applications for attaching insulation as required by
Firestone Specifications.
METHOD OF APPLICATION:
Position insulation plates over insulation as specified by
Firestone Specifications. Attach plates to roof deck using
the appropriate Firestone fastener. Install plates ribbed
side up with the "Firestone" identification visible.
PRECAUTIONS:
• Do not overdrive or underdrive fastener.
• Plates are designed to anchor roof insulation only.
• Avoid field seams directly over insulation plates.
• Cannot be used with Firestone HD Plus Fasteners.
APPROVED
This sheet is meant to highlight Firestone's products and specifications and is subject to
change without notice. Firestone takes responsibility for furnishing quality materials,
which meet Firestone's published product specifications. Neither Firestone nor its
representatives practice architecture. Firestone offers no opinion on and expressly
disaaims any responsibility for the soundness of any structure. Firestone accepts no
liability for structural failure or resultant damages. Consult a competent structural
engineer prior to installation if the structural soundness or structural ability to properly
support a planned installation is in question. No Firestone representative is authorized to
vary this disclaimer.
PRODUCT DATA
Property
Material:
Material Thickness:
Corrosion Resistance:
Pull- Through Resistance:
Diameter:
Minimum Performance
Galvalume® AZ50
0.017" (0.43 mm) - 0.023"
(0.58 mm)
Meets FM No. 4470 criteria
400 Ib (181.4 kg) (min.) from
center hole
3" (76 mm)
Galvalume® is a registered trademark of BIEC Intemational, Inc.
STORAGE:
Store in unopened original containers protected from the
weather.
PACKAGING:
Pail: 1000 plates
Weight: 42 Ib (19 kg) /pail
Pallet: 35 pails
LEED INFORMATION:
Plate with "Firestone T" Identification
Post Consumer Recycled Content: 8%
Post Industrial Recycled Content: 17%
Manufacturing Location: Cleveland, OH
Firestone Building Products Company
250 W. 96'" Street, Indianapolis, IN 46260
Sales: (800) 428 -4442 • Technical (800) 428 -4511
www,firestonebpco.com
S723 -RFS -099
BUILDING PRODUCTS
All- Purpose Fastener
Firestone Item Number:
Red
1 -1/4" W56RAC4200
1-5/8" W56RAC4201
2 -1/4" W56RAC4202
2 -7/8" W56RAC4203
3 -1/4" W56RAC4204
3-3/4" W56RAC4205
4 -1/2" W56RAC4206
W56RAC4207
6" W56RAC4208
W56RAC4209
W56RAC4210
5"
7"
8"
White*
1 -1/4" W56RAC4199
2 -1/4" W56RAC4215
2 -7/8" W56RAC4216
3 -1/4" W56RAC4217
3 -3/4" W56RAC4218
4 -1/2" W56RAC4219
W56RAC4220
W56RAC4221
W56RAC4222
8" W56RAC4223
5"
6"
7"
*Firestone is not responsible for, nor guarantees that the
white coating will remain on the fastener during or after
installation.
Because the coating on Firestone's white fasteners is
removed to some degree during the installation process,
Firestone suggests that 1) the building owner be made
aware of the expectations of the white fasteners and that
re- painting of the deck may be required after roofing is
complete or 2) any deck painting take place after the roof
is installed. In this case, any color of screw will work.
DESCRIPTION:
Firestone AII - Purpose Fasteners are used in roofing
applications for the attachment of roofing insulation and
base sheets in combination with Firestone Insulation
Plates and attachment of Firestone Batten Strips, Seam
Plates, Termination Bars, and other accessories to steel
and wood substrates where approved by Firestone
Technical Specifications. The Firestone AII - Purpose
Fastener is Factory Mutual (FM) approved.
METHOD OF APPLICATION:
Using the #3 Phillips tip provided, and a variable speed
drill, engage the fastener into the deck as noted below,
taking care not to over or under drive the fastener.
Threads must engage the decking material per Firestone
Technical Specifications.
Note: AII - Purpose fasteners may not work as
expected through existing roof systems or unusual
substrates. Consideration should be given to using
Firestone HD fasteners in these instances.
PRECAUTIONARY DATA:
Eye protection must be worn during the installation of the
fasteners.
This sheet is meant to highlight Firestone's products and specifications and is subject to
change without notice. Firestone takes responsibility for furnishing quality materials,
which meet Firestone's published product specification. Neither Firestone nor its
representatives practice architecture. Firestone offers no opinion on and expressly
disdaims any responsibility for the soundness of any structure. Firestone accepts no
liability for structural failure or resultant damages. Consult a competent stnrdurat
engineer prior to installation if the structural soundness or structural ability to properly
support a planned installation is in question. No Firestone representative is authorized to
vary this disdaimer.
Property
Material:
Thread Size:
Threads /Inch:
Thread Design:
Fastener Tip:
Fastener Head:
Pullout in New 22 gauge
(0.76 mm) Steel Deck:
Grade C (Grade 33):
Grade E (Grade 80):
Pullout in New 3/4° (19.0 mm)
Plywood Deck:
Corrosion Resistant Coating:
Screw Length
1 -1/4° (31.75 mm)
1 -5/8° (41.28 mm)
2 -1/4" (57.15 mm)
2 -7/8" (73.03 mm)
3-1/4" (82.55 mm)
3-3/4° (95.25 mm)
4-1/2" (114.3 mm)
5" (127.0 mm)
6° (152.4 mm)
7" (177.8 mm)
8° (203.2 mm)
Minimum Performance
SAE 1022, heat treated steel
0.235° (6.5 mm)
13
Symmetrical
Drill point
#3 Phillips drive
360 Ib (163.3 kg)
400 Ib (191.4 kg)
400 Ib (181.4 kg)
Red epoxy applied by
Electrocoating
Thread Pieces/ Cartons/
Length Plastic Pail Pallet
Full 1,000 60
Full 1,000 60
Full 1,000 60
Full 1,000 60
3° (76.2 mm) 1,000 60
3° (76.2 mm) 1,000 60
3" (76.2 mm) 1,000 60
4" (101.6 mm) 1,000 60
4° (101.6 mm) 1,000 60
4" (101.6 mm) 500 60
4" (101.6 mm) 500 60
Determine required screw length as follows:
Steel Decks: Select fastener length to penetrate
through the deck a minimum of 3/4"
(19.1 mm).
Wood Decks: Select fastener length to penetrate into
or through the deck a minimum of 1"
(25.4 mm).
LEED INFORMATION:
Post Consumer Recycled Content:
Post Industrial Recycled Content:
Manufacturing Location:
25%
0%
Bryan, OH
APPROVED
Firestone Building Products Company
250 W. 96" Street, Indianapolis, IN 46260
Sales: (800) 428 -4442 • Technical (800) 428 -4511
www.firestonebpco.com
S723 -RFS -076
TECHNICAL. INFORMATION SHEET
'Firestone
BUILDING PRODUCTS
ISO 95 +TM GL
Flat and Tapered
DESCRIPTION:
Firestone ISO 95+ GL flat and tapered roof insulation consists of a
closed -cell polyiso foam core laminated to a black glass reinforced mat
facer. Flat and tapered ISO 95+ GL provide outstanding thermal
performance on commercial roofing applications, while providing
positive roof top drainage to help eliminate ponding water when tapered
ISO 95+ GL is used.
All Firestone polyiso insulations use EPA accepted blowing agents and
qualify under the Federal Procurement Regulation for Recycled
Material. Flat and tapered ISO 95+ GL with IsoGard Foam Technology
incorporates a HCFC -free blowing agent that does not contribute to the
depletion of the ozone (ODP -free).
METHOD OF APPLICATION:
Insulation shall be neatly fitted to all roof penetrations, projections and
nailers. No more insulation shall be installed than can be covered with
membrane and completed before the end of each day's work or before
the onset of inclement weather.
NOTE: See Firestone Technical Information Sheet 950 for Insulation
Attachment Pattems.
ISO 95+ GL. FLAT AND TAPERED MUST BE INSTALLED USING:
Fasteners and plates, hot asphalt or Firestone approved insulation
adhesives.
For ballasted systems, the top layer of Firestone insulation may
not be mechanically attached.
ISO 95+ GL Flute S n Over Metal Decks
Thickness
1.0"
1.25"
1.5 " -3.8"
4.0"
Span
2.625"
3.675"
4.375"
4.5"
SPECIFICATION COMPLIANCE:
ASTM C1289, Type II, Class 1
UL Classified
FM Class 1 Approved
Manufactured in an ISO 9002 Registered Facility
CAN/ULC -S704, Type 1, Class 3
APPROVED
CCMC 13274 -L
PI •tyMark"
The Certified lT7R -vole®
This sheet is meant to highlight Firestone's products and specifications and is subject to
change without notice. Firestone takes responsibility for furnishing quality materials,
which meet Firestone's published product specifications. Neither Firestone nor its
representatives practice architecture. Firestone offers no opinion on and expressly
disclaims any responsibility for the soundness of any structure. Firestone accepts no
liability for structural failure or resultant damages. Consult a competent structural
engineer prior to installation if the structural soundness or structural ability to properly
support a planned installation is in question. No Firestone representative is authorized to
vary this disclaimer.
Cellulosic Glass
Reinforced Facer
Foam Core
P1
ODUCT DATA
Insulation Thickness
(inches) (mm)
1.00 25.4
1.25
1.50
1.75
2.00
2.30
2.50
2.80
3.00
3.25
3.50
3.75
4.00
31.7
38.1
44.5
50.8
58.4
63.5
71.1
76.2
82.6
88.9
95.3
101.6
LTTR* R -Value
6.0
7.5
9.0
10.5
12.1
14.0
15.3
17.2
18.5
20.1
21.7
23.4
25.0
*Long Tenn Thermal Resistance (LTTR) values provide a 15 -year
time - weighted average in accordance with CAN/ULC -S770.
POLYISOPHYSICAL PROPERTIES
Physical
Property
ASTM
Test
Compressive Strength* D 1621
Density D 1622
Dimensional Stability D 2126
Moisture Vapor E 96
Transmission
Water Absorption C 209
Service Temperature
English
Values
20 psi, typical
2 pct
<2%
<1.0 Perm
<1% by
Volume
-100° to 250° F
*25 psi (172 kPa) available upon request.
AVAILABLE SIZES:
Flat Boards: 4' x 4' (1.22 m x 1.22 m)
4' x 8' (1.22 m x 2.44 m)
Thickness ranging 1.0" (25.4 mm) to 4.0" (101.6 mm)
Metric
Values
138 kPa, typical
32 kg/m3
<2%
<57.5
ng /(Pa•s•m2)
<1% by
Volume
-73° to 121° C
Tapered Boards: 4' x 4' (1.22 m x 1.22 m)
4' x 8' (1.22 m X 2.44 m) (special order)
Thickness ranging 0.5" (12.7 mm) to 4.0" (101.6 mm)
Slopes ranging 1/16" per foot (.5 %) to' " per foot (4 %)
See chart on page 2.
STORAGE AND PRECAUTIONS:
• Keep insulation dry at all times.
• Elevate insulation above the deck or ground.
• Cover insulation with waterproof tarps.
• Combustible. Refer to MSDS for more information.
• Do not install over wet, damp or uneven substrates.
MANUFACTURING LOCATIONS:
Aurora, CO Florence, KY
Bristol, CT Jacksonville, FL
DeForest, WI
Corsicana, TX
Salt Lake, UT
Youngwood, PA
Firestone Building Products Company
250 W. 96"' Street, Indianapolis, IN 46260
Sales: (800) 428 -4442 • Technical (800) 428 -4511
www.firestonebpco.com
S723 -RFS -066
TECHNICAL INFORMATION SHEET
901
02#08/2010
LEED INFORMATION:
Firestone Resista can help contribute to overall L.E.E.D. certification due to its thermal efficiency (R- Value), recycled content, and zero ozone
depletion. Resista can help achieve valuable credits in the following categories:
• Energy and Atmosphere
- Benefits of commissioning building energy systems include lower energy use and lower operating costs.
- Firestone Resista contains the highest R -Value per inch to help assist in the following credits:
• EA Pre - requisite 2: Minimum Energy Performance
• EA Credit 1: Optimize Energy Performance (1 -19 points)
• Material & Resources
- Benefits include the reduction of waste, as well the preservation of landfill space and raw materials.
- Firestone Resista contains recycled content, can be re -used, and is manufactured strategically across the United States.
• MR Credit 2: Construction Waste Management (1 -2 points)
• MR Credit 3: Material Re -Use (1 -2 points)
• MR Credit 4: Recycled Content (1 -2 points)
• MR Credit 5: Regional Material (1 -2 points)
RECYCLE CONTENT OF ISO 95+ GL
Thickness (inches)
Thickness,
(millimeters)
% Post Consumer
% Post Industrial
TOTAL RECYCLE
CONTENT
1.00
25.40
37%
15%
52%
1.25
31.75
33%
15%
48%
1.50
38.10
29%
15%
44%
1.75
44.45
26%
15%
41%
2.00
50.80
24%
15%
39%
2.30
58.42
21%
15%
36%
2.50
63.50
20%
15%
35%
2.80
71.12
18%
15%
33%
3.00
76.20
17%
15%
32%
3.25
82.55
16%
15%
31%
3.50
88.90
15%
15%
30%
3.75
95.25
14%
15%
29%
4.00
101.60
14%
15%
29%
LEED Reference Guide information can be obtained on line at htto: //www.usabc.ora /.
"LEED is trademark of the U.S. Green Building Council."
TAPERED ISO 95+ GL (Common Panel Types
Panel Code
Min -Max Thickness
Slope
Pieces Per Bundle
(4'x4')
A
0.5 " -1.0"
12.7mm- 25.4mm
1 /8 "/ft.
1%
64
AA
1.0" - 1.5"
25.4 mm - 38.1 mm
1 /8 "/ft.
1%
38
B
1.5" - 2.0"
38.1 mm - 50.8 mm
1 /8 "/ft.
1%
26
C
2.0 " -2.5"
50.8mm- 63.5mm
1 /8 "/ft.
1%
20
G
1.0" - 2.0"
25.4 mm - 50.8 mm
1 /4 "/ft.
2%
32
H
2.0" - 3.0"
50.8 mm - 76.2 mm
1/4"Ift.
2%
18
I
3.0" - 4.0"
76.2 mm -100.6 mm
1 /4 "/ft.
2%
12
X
0.5" - 1.5"
12.7 mm - 38.1 mm
114 " /ft.
2%
48
Y
1.5" - 2.5"
38.1 mm - 63.5 mm
1/4"/ft.
2%
24
Z
2.5" - 3.5"
63.5 mm - 88.9 mm
1 /4 "/ft.
2%
16
Q
0.5" - 2.5"
12.7 mm - 63.5 mm
1 /2 "/ft.
4%
32
Contact Firestone's Estimating Services Department for a project quotation or for layout guidance. For site assistance or contractor
support, contact Firestone's Tapered Project Management Team by calling: 1- 800 - 428 -4442 or by emailing:
estimatinaservicesdeotOfirestonebo. com
1 /8 " /ft. Tapered Section
0.5"
1 /2 "/ft. Tapered Section
1 /4 " /ft. Tapered Section
0.5"
1 /4 " /ft. Tapered Section
Contact Firestone's Estimating Services Department for a project .quotation or for layout guidance. For site assistance or contractor
support, contact Firestone's Tapered Project Management Team by calling: 1- 800 -428 -4442 or by emailing:
estimatinoservicesdept (firestonebo.com
S723 -RFS -066
TECHNICAL INFORMATION SHEET
201
1/26/2010
'Firestone
BUILDING PRODUCTS
Ultra Ply TM TPO
DESCRIPTION:
Firestone UltraPlyTM TPO is a flexible Thermoplastic
Polyolefin roofing membrane that is produced with
polyester weft- inserted reinforcement. This heat
weldable TPO membrane is available in 45 mil (1.1 mm)
and 60 mil (1.5 mm) thicknesses in 8' (2.4 m), 10' (3 m)
and 12'4" (3.76 m) widths. The colors available are
white, tan or gray. This reflective membrane is suitable
for a variety of low slope applications.
METHOD OF APPLICATION:
1. Firestone UltraPly TPO membrane is installed as
continuous roofing or waterproofing layer on the roof.
Rolls are overlapped (side laps and end laps) prior to
the heat welding of the seam areas.
2. Install the UltraPly TPO Roofing System in
accordance with current Firestone UltraPly TPO
specifications, details and workmanship
requirements.
3. Please contact Firestone Roofing Solutions or visit
the Firestone Technical Database for additional
information at www.Firestonebpco.com.
PRODUCT DATA:
Thickness: 0.045" (1.1 mm)
0.060" (1.5 mm)
Width: 5 ft to 12 ft 4 in (1.5 m to 3.75 m)
Length: 100 ft (30.5 m)
Colors: White, Tan, Gray
CRC
k{n Il k+ ' it
111 ♦c.��H \. II
CHARTER
MEMBER
ENERuv STAR
This sheet is meant to highlight Firestone's products and specifications and is subject to
change without notice. Firestone takes responsibility for fumishing quality materials,
which meet Firestone's published product specifications. Neither Firestone nor its
representatives practice architecture. Firestone offers no opinion on and expressly
disclaims any responsibility for the soundness of any structure. Firestone accepts no
liability for structural failure or resultant damages. Consult a competent structural
engineer prior to installation if the structural soundness or structural ability to property
support a planned installation is in question. No Firestone representative is authorized to
vary this disdaimer.
STORAGE:
• Store away from sources of punctures, and physical
damage.
• Assure that structural decking will support the loads
incurred by material when stored on rooftop. The deck
Toad limitations should be specified by the project
designer.
• Store away from ignition sources as membrane will
burn when exposed to open flame.
PRECAUTIONS:
• Exercise caution when lifting, moving, transporting,
storing or handling membrane rolls to avoid sources of
punctures and possible physical damage.
• Contact Firestone Roofing Solutions Department for
specific recommendations regarding chemical or waste
product compatibility with Firestone UltraPly TPO
Membrane.
• Refer to Material Safety Data Sheets (MSDS) for safety
information
LEED INFORMATION:
Post Consumer Recycled Content:
Post Industrial Recycled Content:
Manufacturing Location:
APPROVED
CCMC 13348 -R
MIAMI -DADE COUNTY
APPROVED
0%
15%
Wellford, SC
Las Vegas, NV
Tuscumbia, AL
Firestone Building Products Company, LLC
250 W. 96"' Street, Indianapolis, IN 46260
Sales: (800) 428-4442 • Technical (800) 428 -4511
www.firestonebpco.com
S723 -RFS -012
TECHNICAL INFORMATION SHEET
. ......_ ...
201
1/26/2010
UltraPlyTM TPO
reston4
BUILDING PRODUCTS
PHYSICAL PROPERTIES
Property
Test Method
ASTM D 6878
Specification
Typical Values
45 mil
60 mil
Overall Thickness
ASTM D751
0.039" (1.0 mm) min
0.045" (1.1 mm)
±10%
0.060" (1.5 mm)
±10%
Coating Over Scrim
ASTM D6878, Annex A
0.012" (0.305 mm) min
0.020" (0.51 mm)
0.025" (0.64 mm)
Breaking strength
ASTM D751, Grab Method
2201b1 (975 N) min
340 Ibf (1,510 N)
390 Ibf (1,730 N)
Elongation at Reinforcement Break
ASTM D751, Grab Method
15% min
25%
25%
Tearing Strength
ASTM D751
55 Ib, (245 N) min
120 Ib, (530 N)
120 IN (530 N)
Brittleness Point
ASTM D2137
-40 °F (-40 °C)
Pass
Pass
Ozone resistance, no cracks
ASTM D1149
Pass (no cracks)
Pass
Pass
Heat Aged Properties
ASTM D573
Retention of Breaking Strength
ASTM D751, Grab Method
90% min
> 90%
> 90%
Elongation at Reinforcement Break
ASTM D751, Grab Method
90% min
> 90%
> 90%
Retention of Tearing Strength
ASTM D751
60% min
> 60%
> 60%
Weight Change (Membrane)
± 1% max
< 1%
< 1%
Linear Dimension Change
ASTM D1204
6 h at 158 °F (70 °C)
± 1% max
< 1%
< 1%
Water Absorption
ASTM D471
± 3.0% max
< 3%
< 3%
Weather Resistance
ASTM G155, 80 °C Black
Panel, no cracking, crazing
when wrapped around a 3"
mandrel and inspected at 7x
magnification
10,080 kJ /m2 min
> 20,160 kJ /m2
> 20,160 kJ /m2
Puncture Resistance
FTM 101C Method 2031
-_
265 Ibf (1,180 N)
300 Ibf (1,300 N)
Values were obtained from independent testing for the CRRC table below.
SRI is calculated from Solar Reflectance Index (SRI) calculator from the USGBC.
ENERGY STA
Tai
1 !
only
. Cool ft oaf flU ncu )
M1th a
Tan
Grayr
Initial Solar Reflectance
0.79
0.60
ASTM E408
Solar Reflectance Initial
0.79
0.60
Solar Reflectance Index (SRI)
Aged Solar Reflectance (3 years)
0.78
0.54
43
Solar Reflectance Weathered
0.68
0.55
Cleaned prior to aged test?
Yes
No
Thermal Emittance Initial
0.85
0.81
Initial Emittance
0.85
0.81
Thermal Emittance Weathered
0.83
0.84
LEED
Tai
Yyltila
Tan
c>ty►
Solar Reflectance
ASTM E903
0.81
0.63
0.37
Thermal Emittance
ASTM E408
0.95
0.95
0.95
Solar Reflectance Index (SRI)
ASTM E1980
102
77
43
S723 -RFS -012
XrT
Tk.
3`v
06 -01 -2011
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
RICHARD BOMARS
1551 127 PL NE
BELLEVUE WA 98005
RE: Permit No. D11 -001
5219 S 144 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 07/06/2011.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 07/06/2011, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
.—i;1 c
Bill Rambo
Permit Technician
File: Permit File No. DI 1 -001
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
0110PERMITCOORDCOPY�
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -001 DATE: 01/03/11
PROJECT NAME: ANGRY SQUID INK
SITE ADDRESS: 5219 S 144 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS.
�I Ind LJIViSlO
Public Works
A- NIA 0
Fire Prevention
❑ Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Nk
Comments:
Incomplete
DUE DATE: 01/04/11
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route ❑ Structural Review Required ❑ No further Review Required
DATE:
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
DUE DATE: 02/01/11
Approved 1 Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Piper Friendly Page
•
Page 1 of 1
General /Specialty Contractor
A business registered as a construction contractor with LEtI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name CERTIFIED CONTRACTORS INC UBI No. 601794580
Phone 4256469441 Status Active
Address 1551 127Th Pt Ne License No. CERTICI032L5
Suite /Apt. License Type Construction Contractor
City Bellevue Effective Date 6/25/1997
State WA Expiration Date 2/14/2011
Zip 98005 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
r Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
FACTOCC077PH
FACTORY CERTIFIED
CONTRS INC
Construction
Contractor
General
Unused
10/8/1993
1 /5/1998
Archived
CERTIC*088QL
CERTIFIED
CONTRACTORS
Construction
Contractor
General
Unused
11/13/1992
11/13/1993
Archived
BOMARRJ100QB
BOMARS, RICHARD J
Construction
Contractor
General
Unused
11/2/1990
10/2/1992
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BOMARS, RICHARD J
President
06/25/1997
Bond Information
Bond I
Bond Company Name
I
Bond Account Number
I Effective Date I Expiration Date
https://fortress.wa.gov/lni/bbip/Print.aspx
01/05/2011