Loading...
HomeMy WebLinkAboutPermit D11-033 - SIGHTLINE HEALTH - INTERIOR DEMOLITIONSIGHTLINE HEALTH INT'F.RIOR DEMO 200 ANDOVER PK E EXPIRED 10 -05 -I1 Dl 1 -033 City oPI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htux/Iwww.ci.tulcwila.wa.us DEVELOPMENT PERMIT Parcel No.: 0223100099 Address: 200 ANDOVER PK E TUKW Suite No: Project Name: SIGHTLINE HEALTH INTERIOR DEMO Permit Number: D11 -033 Issue Date: 03/22/2011 Permit Expires On: 09/18/2011 Owner: Name: ANDOVER PLAZA LLC Address: 1501 N 200TH ST , SHORELINE WA 98133 Contact Person: Name: TED BRANDVOLD Address: 616 14 ST , MODESTO CA 95364 Contractor: Name: WELLER CONSTRUCTION INC Address: PO BOX 1134 , COLUMBIA CA 95310 Contractor License No: WELLECI916CE Phone: 209 571 -8158 Phone: Expiration Date: 02/18/2013 DESCRIPTION OF WORK: INTERIOR DEMOLITION IN PREPARATION FOR FUTURE TENANT IMPROVEMENTS. Value of Construction: $10,000.00 Fees Collected: $464.52 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIIB Occupancy per IBC: 0008 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11 -033 Printed: 03 -22 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: Private: Profit: N Private: Date: Public: Non - Profit: N Public: I hereby certify that I have read and e - d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t ••- 4 rfo ce of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit,/ Signat ; - Pn — J 6\ Thi • ermit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -033 Printed: 03 -22 -2011 6: ** *FIRE DEPARTMENT CONDITIONS * ** 0 • 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 9: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 11: Arty overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 12: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -033 Printed: 03 -22 -2011 CITY OF TUK Community Devel ent Department Public Works Department Permit Center -- " 6300 Southcenter Blvd., Suite 100 Tukwila, . WA 98188. http://www.ci.tukwila.wa.us Building PereNo. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. Mll -�-2 •12q- 0 2 X11 -01°x. (For office use only) Applications and plans must be complete in order to•be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: �OC� Tenant Name: Property Owners Name: / Ov King Co Assessor's Tax No.: 67 Z Suite Number:ic2 Floor: /G�lfTG /i✓� f� New Tenant: ❑ Yes Mailing Address: .. No State 1. CONTACT PERSON - who do we contact when your Permit is ready to be issued • Name: ?a_, sz�.r��1/cx, Pte- Day Telephone: �ZZl . "5-74 (4>/e_7 Mailing Address:‘//e...- /4' -PI/ e� � i�-1 ' 4 cep •=7.4 City E -Mail Address: Ga•••?/% ifg'G,lisL_!3./la c t-= 4 Fax Number: .5"7f . C� State zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical:(pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: ' I— -A je Gcysl��,�2j Q�, U.IG • Mailing Address: Fd ox //�' �.,r�. ,d,/i.•1 Contact Person: E-Mail Address: Lc/. (.4... 41C Contractor Registration Number: V ✓, GL G /9 / 1. �G•9E: City Day Telephone: • 532 • e '. State Zip Fax Number: .04:::0q • e%/p 4/ Expiration Date: ARCIIITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: State zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: 9 2 O Pint ;1- Contact Person: E -Mail Address: H:\Appliations‘Ponm- Applications On Line\2010 Applications\7 -2010 - Permit Applicationdoe Revised: 7 -2010 bh Ck q� l City state Zip Day Telephone: • 4:05• !av A a 220 i Fax Number: deiZA i Page 1 of 6 BUILDING PERMIT INFORMATIOj 206- 431 -3670 Valuation of Project (contractor's bid price): '$ ler7/ a • Existing Building' Valuation: $ Scope. of Work (please provide detailed information): Will there be, new rack ,storage? ■ ...Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of, all ,structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an. Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking,Stalls Provided: Standard: Compact: Handicap: - Willthere,be a change in use? ❑ Yes ❑ -_ No If "yes ",,explain: FIRE PROTECTION/:HAZARDOUS'MATERIALS 40 _ Sprinklers IV% Automatic Fire Alarm ❑ None ■ Other (specify) Wilhthere be storage or ,use of flammable, combustible orlhaznrdous materials in the building? i❑ Yes No If "yes', attach list of materials,andstorage locations on a separate ,8 -1/2 " x 11 "paper including guantities and Material Saje ata Sheets. SEPTIC SYSTEM On-site Septic System— For on -site septic system, provide 2 copies of a current septic ,design approved by King County Health Department. , ri:\Applicationaorm Applications On Liae12010 Applications17- 2010 - ;Permit Application. doe `Revised; 7 =2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing ; Structure I New Type of Construction per IBC Type of . Occupancy per IBC 1" Floor / _ 2ndf loor 3`" Floor Floors thru,. I Basement Accessory Structure* Attached Garage I Detached Garage Attached Carport • I Detached Carport Covered Deck Uncovered Deck • PLANNING DIVISION: Single family building footprint (area of the foundation of, all ,structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an. Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking,Stalls Provided: Standard: Compact: Handicap: - Willthere,be a change in use? ❑ Yes ❑ -_ No If "yes ",,explain: FIRE PROTECTION/:HAZARDOUS'MATERIALS 40 _ Sprinklers IV% Automatic Fire Alarm ❑ None ■ Other (specify) Wilhthere be storage or ,use of flammable, combustible orlhaznrdous materials in the building? i❑ Yes No If "yes', attach list of materials,andstorage locations on a separate ,8 -1/2 " x 11 "paper including guantities and Material Saje ata Sheets. SEPTIC SYSTEM On-site Septic System— For on -site septic system, provide 2 copies of a current septic ,design approved by King County Health Department. , ri:\Applicationaorm Applications On Liae12010 Applications17- 2010 - ;Permit Application. doe `Revised; 7 =2010 bh Page 2 of 6 PUIiLIC WORKS PERMIT INFOATION — 206 - 433 -0179 Scope of Work (please provide detailed information): •■/ /G Call before you Dig: 1-800-424-5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water. District ❑' . Tukwila ❑ .. Water Availability Provided Sewer District t]`.. Tukwila ❑ :. Sewer Use Certificate ❑ ...Water District #125 ❑... Highline ❑;..Valley View , ❑...Renton ❑ ...Sewer Availability Provided 0... Renton .0... Seattle Septic System: ❑ ' 'On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted:. with:Application (mark boxes which apply): .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance ❑ ... Easement(s) Proposed Activities (mark boxes that apply): ❑-.. Right-of-way Use - Nonprofit for less than 72 hours ❑ Right -of -way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right -of -way ❑ Non Right -of -way ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size.. ❑ .. Temporary Water Meter Size . ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ ❑ .. Water Main Extension Public ❑ 0... Geotechnical Report ❑ ... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours ❑ ... Right -of -way Use — Potential Disturbance 0... Work in Flood Zone ❑ ... Storm Drainage ❑...Abandon Septic Tank ❑...Curb Cut 0... Pavement Cut 0... Looped Fire Line 11 11 11 11 WO # WO # WO # Private ❑ Private ❑ 0... Grease Interceptor ❑... Channelization 0... Trench Excavation 0... Utility Undergrounding ❑ .. Deduct Water Meter Size 11 FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: city State zip H:\Applications\Fonna- Applications On Line \2010 Application \7 -2010 - Permit Application.doc Revlaed: 7-2010 bh Page 3 of 6 MECHANICAL PERMIT INFORMAON — 206 - 431 -3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City State Zip Day Telephone: Fax Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ • Scope of Work (pleaae provide detailed information): J lolfrIgeeteiVE �..��!°�.c�✓ .✓mac �•t-r �.c/ .,�fi�,�G o�./ ��� SQC2 r c,/ Use: Residential: New.... ❑ Replacement.... ❑ Commercial: New.... ❑ Replacenent .... ,❑ Fuel Type: Electric ❑ Gas.... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnacx>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connectxd to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H :1ApplicationstFonns-Applications On Line \2010 Applicationsl7 -2010 - Permit Applieation.itoc Revised: 7 -2010 bh Page 4 of 6 PLUMBING AND GAS PIPING PER1'SINFORMATION — 206 - 431 -3670 • PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City state Zip Day Telephone: Fax Number: Expiration Date: Valuation of Plumbing, work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): /b' Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture .Type: Qty . Fixture Type: Qty Bathtub or combination bath/shower. Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent . Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each•grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) . diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric-type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets HAAppliations\Forms Appliations On Line \2010 Appliations \7 -2010 - Pmnit Application doc Revised: 7 -2010 bb Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules_ Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing ,and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O�VN, R OR AUTHORIZED AGENT: Signature: , Date:. 2. 4 . • Print Day Telephone: Mailing Address:'/ GP /4 -7-'11 �{ c � ���r�,e U � '1 =7,5 LJ City State Zip Date Application Accepted: 02 O t Date Application Expires: I 0 q 1 i ` toA Staff Initials: / x, 1 H:\ApplicationsFFortns- Application On Line \2010 Applications\7 -2010 - Permit Application.loc Revised: 7 -2010 bh Page 6 of 6 Ci, of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: /hvww. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 03 -22 -2011 at 09:31:52 03/22/2011 RECEIPT NO: R11 -00555 Initials: JEM Payment Date: 03/22/2011 User ID: 1165 Total Payment: 1,866.70 Payee: MR. JEFFREY J WELLER SET ID: 0322 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D11 -033 EL11 -0077 TOTAL: 283.30 1,583.40 283.30 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,866.70 TOTAL: 1,866.70 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 640.237.114 TOTAL: 278.80 1,583.40 4.50 1,866.70 of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: hap: //www. ci. tukw ila. wa. us SET RECEIPT RECEIPT NO: R11 -00249 Initials: JEM User ID: 1165 Payee: COMMERCIAL ARCHITECTURE, INC. Payment Date: 02/09/2011 Total Payment: 255.22 SET ID: S000001474 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D11 -033 EL11 -0105 M11 -022 PG11 -027 TOTAL: Amount 181.22 28.88 29.89 15.23 181.22 TRANSACTION LIST: Type Method Description Amount Payment Check 10709 255.22 TOTAL: 255.22 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 28.88 226.34 TOTAL: 255.22 r ye • • INSPECTION RECORD • Retain a copy with permit bj 1-0 3,7% INSPECTION Na PERMIT NO. •CITY OF-TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431=2451 Project: .., % Type o spectiOn: ei, 6,..y -,--) .,e,...i,4/14/3 iy-Abo,-, 7 pe- 4eref 74 i t4 /),...,.44 i-i1A/,1 Address: /49,0064,44 Pg 6- Date Called: '7_5) JD IsSetir7V-1101174 104/ k irni all) /177 .2i "/ 7 I L 7--- R,...fer-) • . • I._ ozego Special Instructions: . . • 7--- //2■01 177. . Date Wanted: 41...... P.:: ...„ 4, i IC a ro. p.m. Requester: ' Phone No.-, ElApproved per applicable codes. -10• Corrections required prior to approval. COMMENTS: 0 /nee 4/910 4?-44 i 'e P r Al itilordir ,90/ -,--) .,e,...i,4/14/3 iy-Abo,-, 7 pe- 4eref 74 i t4 /),...,.44 i-i1A/,1 eg7---..x j�wrr a iiay / - '7_5) JD IsSetir7V-1101174 104/ k irni all) /177 .2i "/ 7 I L 7--- R,...fer-) • . I._ 1-- - SPECTION FEE.REQUI ED. Prior next inspection. fee must be id at 6300 Southcenter Blvd.. Suite Call to schedule reinspection. • '.• -• •.•vap- AT: • • a ' •• 09 -01 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director TED BRANDVOLD 616 14 ST MODESTO CA 95364 RE: Permit No. D11 -033 200 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/05/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/05/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D11 -033 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 IDPERMITCOORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -033 DATE: 02/09/11 PROJECT.NAME: SIGHTLINE HEALTHCARE INTERIOR DEMO SITE ADDRESS: 200 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART ENTS: (0_4A Vulirciing Division ire Prevention Planning Division (I1s 2-;" I1 blic Wor s OE Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Ly,1 Comments: Incomplete n DUE DATE: 02/10/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Structural Review Required n No further Review Required ❑ Please Route tit REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03/10/11 Not Approved (attach comments) E DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople tier Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WELLER CONSTRUCTION INC UBI No. 602793194 Phone 2095320686 Status Active Address Po Box 1134 License No. WELLECI916CE Suite /Apt. License Type Construction Contractor City Columbia Effective Date 2/5/2009 State CA Expiration Date 2/18/2013 Zip 95310 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date WELLER, JAMES J Member 02/05/2009 Amount WELLER, DEANNA L Member 02/05/2009 G24014009004 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO (DEVS) 780941c 01/08/2009 Until Cancelled $12,000.00 02/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 WESTCHESTER FIRE INS COMPANY G24014009004 03/08/2011 03/08/2012 $1,000,000.0003 /22/2011 1 Westchester Fire Ins Company G24014009003 03/28/2008 03/08/2011 $1,000,000.0003 /16/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 03/22/2011 CC W CO CHRISTENSEN ROAD 10 C C c C 0 /o 0 0 C 10 C 1 am Hie '.r 0 0 C C 0 0 EXISTING BUILDING 32,156 SQUARE FEET mum 1■iQlP'��s► 1■■ ■ ■■. 1 ■■ ■■ ■s, 1 ■ ■ ■Y �■110 101111111 NIL— r-, 12 AP Atir G�Ca� 14 0 C C 0 C C C SITE SCALE: 1" = 30' -0" PLAN ANDOVER P ARK EAST PROJECT TEAM GENERAL NOTES OWNER SIGHTLINE HEALTH 760 ANDOVER PARK WEST TUCKWILA, WASHINGTON GENERAL CONTRACTOR WELLER CONSTRUCTION P.O. BOX 1134 COLUMBIA, CALIFORNIA 95310 PH. (209) 532 -0686 FAX (209) 532 -0641 MECHANICAL DESIGNER ALEXANDER SCHEFLO 8, ASSOCIATES 2926 PACIFIC AVENUE STOCKTON, CA 95219 P11. (209) 948 -9761 FAX (209) 948 -1258 STRUCTURAL ENGINEER CHG STRUCTURAL CONSULTANTS 1030 llth STREET MODESTO, CA 95354 PH. (209) 996 -6340 DESIGNER COMMERCIAL ARCHITECTURE, INC. 616 14TH STREET MODESTO, CA 95354 PH. (209) 571 -8158 FAX (209) 571 -8160 ELECTRICAL DESIGNER HCS ENGINEERING, INC. 4512 FEATHER RIVER DRIVE STOCKTON, CA 95219 PH. (209) 478 -8270 FAX (209) 478 -2169 PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. SEPARATE PERMIT REQUIRED FOR: E Mechanical l Iectricai Lit Plumbing tas Piping City of Tukwila P. DING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. . CONTRACTOR SHALL VERIFY EXACT CONDITIONS AND DIMENSIONS IN THE FIELD. . ADEQUATELY PROTECT ALL PERSONNEL AND THE PUBLIC FROM HARM AND ACCIDENTS DURING WORK OF THIS PROJECT, BY THE ERECTION OF PROPER BARRICADES, SIGNS AND LIGHTING AS MAY BE NECESSARY. 3. ADEQUATELY PROTECT FROM DAMAGE TO EXISTING BUILDINGS AND SURFACES ADJACENT TO WORK OF THIS PROJECT. . NO ENCLOSURE, SHIELD, OR PROTECTIVE COVERING SHALL INTERFERE WITH USE OF FIRE LANES OR PUBLIC EGRESS AT ANY TIME. ALL RUBBISH AND DEBRIS SHALL BE HAULED AWAY FROM THE SITE PROMPTLY AND LEGALLY DISPOSED OF BY THE CONTRACTOR. 6. EXCESSIVELY NOISY OR DISRUPTIVE FUNCTIONS SHALL BE PERFORMED AT TIME OF MINIMUM INTERRUPTION TO NORMAL BUSINESS OPERATION. 7. CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM ACCUMULATIONS OF WASTE OR RUBBISH CAUSED BY HIS EMPLOYEES OR WORK, OR THE EMPLOYEES OR WORK OF THE SUBCONTRACTOR AND AT THE COMPLETION OF THE WORK SHALL REMOVE ALL DEBRIS FROM AND ABOUT THE PROJECT AREA AND SHALL LEAVE THE AREA IN A "BROOM CLEAN" MANNER. 8. NO MATERIAL OR EQUIPMENT SHALL BE LEFT ON THE PROJECT SITE OVERNIGHT UNSECURED. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING CONCRETE WALKS, LANDSCAPING, IRRIGATION SYSTEMS, ETC., WHICH MAY BE DAMAGED BY WORK OF THIS PROJECT. 10. ALL CONSTRUCTION SHALL CONFORM TO CURRENT NATIONAL CODES WITH WASHINGTON STATE AMENDMENTS: STRUCTURAb.NyNTERNATIONAL BUILDING FIRE: 1NT ' ► . TIONAL Fl ELECTRICAL: NATIONAL E ■�' • ' - - - MECHANICAL: INTERNA AL MECHC PLUMBING: UNIF • ' PLUMBING CODE, 201 ENERGY: WASHINGTON STATE ENERGY CODE, WASHINGTON STATE INDOOR AIR QUALIT , 2010 EDITION ODE, 2010 EDITION. CODE. 2010 EDITION CODE, 20107 EDITION ITION 6 EDITION DE, 2006 EDITION 11. CHANGE IN THE APPROVED PLANS AND SPECIFICATIONS SHALL BE MADE BY CHANGE ORDER SIGNED BY THE OWNER AND ARCHITECT. 12. TESTS OF MATERIALS SHALL BE CONDUCTED BY A TESTING LAB SELECTED BY THE OWNER WITH THE APPROVAL OF THE ARCHITECT. THE OWNER SHALL PAY THE COSTS OF ALL TESTS. 13. ALL POURED IN PLACE CURBS SHALL BE POURED W/ 3,000 PSI CONCRETE AND SHALL HAVE CONSTRUCTION JOINTS AT 20' -0" O.C. 14. CONTRACTOR SHALL COORDINATE ANY OFFSITE TRENCHING WITH LOCAL JURISDICTIONAL AUTHORITY. 15. AS BUILT" DRAWINGS: THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL PROVIDE 1 (ONE) REPRODUCIBLE SET OF AS BUILT" DRAWINGS INDICATING LOCATIONS OF UTILITY LINES BY DIMENSION. THESE DRAWINGS SHALL REPRESENT ACTUAL CONSTRUCTION LAYOUT AND LOCATIONS AND SHALL BE DELIVERED TO ARCHITECT WITHIN 30 (THIRTY) DAYS OF FINAL PUNCH LIST COMPLETION. CITY OF TUCKWILA NOTES 1. THESE PLANS AND RELATED DOCUMENTS MUST BE AVAILABLE AT THE JOB SITE DURING ANY INSPECTION ACTIVITY. 2. STREET ADDRESS AND NUMBER SHALL BE POSTED PRIOR TO THE FIRST INSPECTION AND INSTALLED PER ADOPTED FIRE PROTECTION DEPARTMENT STANDARDS. 3. DISABLED ACCESSIBLE PARKING SIGNAGE SHALL BE PROVIDED AT ALL ENTRANCES TO THE PARKING LOT, AT ALL ACCESSIBLE PARKING STALLS, AT ALL PRIMARY ENTRANCES TO THE BUILDING /SITE, AT ACCESSIBLE FITTING ROOMS, AND AT ACCESSIBLE RESTROOMS. 4. THIS PERMIT DOES NOT APPROVE ANY EXTERIOR SIGNAGE. A SEPARATE PERMIT IS REQUIRED FOR ALL SIGNS. CQPY Permit No. 3 Pil.n review approval is subject to errors and omissions. t;pr :� ova! of construction documents does not authorize lh: violation of any ado.ted code or ordinance. Receipt c` Qpprov Fie . ' p - d conditions is acknowledged: City Of Ytakwila BUILDING DIVISION 0 KEYNOTES DRAWING INDEX CODE DATA VICINITY MAP 0 0 0 10 11 12 13 14 PROPERTY LINE, TYPICAL. EXISTING ASPHALTIC CONCRETE PAVING TO REMAIN, TYPICAL. EXISTING ACESSIBLE PARKING STRIPING, TO REMAIN - NO WORK EXISTING CITY STANDARD PARKING STRIPING TO REMAIN, TYPICAL - NO WORK EXISTING LANDSCAPE PLANTER TO REMAIN, TYPICAL NO WORK EXISTING CONCRETE WALK, TYPICAL - NO WORK EXISTING CITY STANDARD DRIVE APPROACH AND DRIVE TO REMAIN, TYPICAL - NO WORK EXISTING EXTERIOR EXIT DOOR TO REMAIN, SEE DRAWING A -7.0 FOR HARDWARE MODIFICATIONS ACCESSIBLE PATH OF TRAVEL AS INDICATED. EXISTING ELECTRICAL TRANSFORMER. EXISTING TRASH ENCLOSURE. EXISTING CONCRETE CURB, GUTTER, AND WALK. EXISTING GAS SERVICE /METER LOCATION. EXISTING FIRE RISER LOCATION /CLOSET. ARCHITECTURAL A -1.0 SITE PLAN, GENERAL NOTES A -2.0 DEMOLITION FLOOR PLAN A -3.0 DEMOLITION CEILING PLAN MECHANICAL M -1.0 MECHANICAL DEMOLITION PLAN PLUMBING P -1.0 DEMOLITION FLOOR PLAN ELECTRICAL E -2 ELECTRICAL DEMOLITION PLAN ASSESSOR'S PARCEL NUMBER: PROJECT ADDRESS: JURISDICTION: ZONING: EXISTING BUILDING AREA: PROJECT AREA: TYPE OF CONSTRUCTION: FIRE SPRINKLERS: 0223100099 200 ANDOVER PARK EAST TUCKWILA, WA CITY OF TUCKWILA TUC 32,156 SQUARE FEET 10,840 SQUARE FEET III B YES, EXISTING TO BE MODIFIED UNDER FUTURE TENANT IMPROVEMENT PERMIT THIS PERMIT FOR DEMOLITION ONLY IEVANS BLACK DRI BAKER BLVD STRANDER BLVD OVER Z REVIEWED FOR -- CODE COMPLIANCE APPRCIVED FEB 17 2011 City of Tukwila BUILDING DIVISION RECEIV cITY OFTU LA FEB. 0 9 2011 PERMIT CENTER OCT 0 5 2011 PROJECT LOCATION 200 ANDOVER PARK EAST TUKWILA, WA L: \2010 \10 - 175 \CD's \Demolition Permit\ COLUMBIA, CA 95310 w Z •t I- V) Qco wr sz co Q O' Q ce >< 0=' z O O I- N 2/7/2011 12:55 PM DRAWN SLW CHECKED TJ B DATE 1 0/22/1 0 SCALE AS SHOWN JOB NO, 1 0-1 75 ♦ SHEET A 1 ■ 0 OF SHEETS • 2/7/2011 12:55 PM DEMOLITION FLOOR PLAN SCALE: 1/8" = 1 111 111 111 _L1 1 I L - I H 1— LL_ 11 L_ L } - - -- 7 n r5 F 1 / L 1 1 ; 11 •1 1 —_ \ 11 \ \ 11 \ II 1 rf - - -- J ❑ 2 H P- - -- I, , 1 , I sr — = � — — I1IIL 11 1 '11111. I _ _, LIIIIILJ 11111 II II �\ 11 II II 1 6 IIIIII 11IIII11 IIIIIIII IIIIII C= 1 1 r-� 11 \ \ 4 1 r 1\ ,_ = == , LL 7 L 0 KEYNOTES 0 0 0 0 EXISTING WALL TO BE REMOVED WHERE INDICATED. EXISTING INTERIOR DOOR TO BE REMOVED WHERE INDICATED. EXISTING WASTE CLOSET TO BE REMOVED. SEE PLUMBING EXISTING STRUCTURAL COLUMN TO REMAIN. SEE STRUCTURAL — VERIFY EXACT LOCATION EXISTING ELECTRICAL PANELS — SEE ELECTRICAL EXISTING ALUMINUM STOREFRONT DOORS TO BE REMOVED. PROVIDE NEW STOREFRONT WINDOW SYSTEM AS REQUIRED TO MATCH EXISTING. 0 PROVIDE NEW 3' -0" WIDE STOREFRONT DOOR IN EXISTING ALUMINUM STOREFRONT SYSTEM. MODIFY EXISTING STOREFRONT SYSTEM AS REQUIRED TO MATCH EXISTING. DOOR HEIGHT TO MATCH EXISTING, ADJACENT STOREFRONT DOORS. SEE DOOR SCHEDULE. 80 EXISTING EXTERIOR DOOR TO REMAIN. O 00000000 REMOVE ALL FINISH FLOORING MATERIAL AND ALL RELATED ADHESIVES AND FASTENERS THROUGHOUT PROJECT AREA. EXISTING TRANSFORMER — SEE ELECTRICAL. WALL MOUNTED FAN COIL UNIT — SEE MECHANICAL /ELECTRICAL DRAWINGS. EXISTING LAVATORY /COUNTER TO BE REMOVED — SEE PLUMBING. EXISTING URINAL TO BE REMOVED — SEE PLUMBING. EXISTING RESTROOM PARTITION TO BE REMOVED. EXISTING CASEWORK TO BE REMOVED. EXISTING SINK TO BE REMOVED — SEE PLUMBING. EXISTING EXPOSED CONCRETE SLAB TO REMAIN. OCT 0\5 2011 bl1O33 DEMOLITION NOTES (CONTD ON DRAWING A -1.2) A. PERFORMANCE CRITERIA A.A. REQUIREMENTS OF STRUCTURAL WORK: DO NOT CUT EXISTING STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD — CARRYING CAPACITY OR LOAD / DEFLECTION RATING. A.B LOADING: DO NOT SUPERIMPOSE LOADS AT ANY POINT UPON EXISTING STRUCTURE BEYOND DESIGN CAPACITY INCLUDING LOADS ATTRIBUTABLE TO MATERIALS, CONSTRUCTION EQUIPMENT, DEMOLITION OPERATIONS AND SHORING AND BRACING. A.C. VIBRATION: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD INDUCE VIBRATION INTO ANY ELEMENT OF THE STRUCTURE. A.D. FIRE: DO NOT USE MEANS, METHODS, TECHNIQUES, OR PROCEDURES WHICH WOULD PRODUCE ANY FIRE HAZARD. A.E. WATER: DO NOT USE MEANS, METHODS, TECHNIQUES OR PROCEDURES WHICH WOULD PRODUCE EXCESSIVE WATER RUN —OFF, AND WATER POLLUTION. A.F. AIR POLLUTION: DO NOT USE MEANS, METHODS, TECHNIQUES, OR PROCEDURES WHICH WOULD PRODUCE UNCONTROLLABLE DUST, FUMES, OR OTHER DAMAGING AIR POLLUTION. B. REGULATORY REQUIREMENTS: B.A. CONFORM TO APPLICABLE CODE FOR DEMOLITION WORK, DUST CONTROL, PRODUCTS REQUIRING ELECTRICAL DISCONNECTION AND / OR RE— CONNECTION. B.B. DO NOT CLOSE OR OBSTRUCT REQUIRED EGRESS FROM ANY BLDG EXIT OR SITE EXIT. B.C. CONFORM TO APPLICABLE REGULATORY PROCEDURES WHEN HAZARDOUS OR CONTAMINATED MATERIALS ARE DISCOVERED. C. PROJECT CONDITIONS C.A. C.B. VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. PERFORM THE REMOVAL, CUTTING, DRILLING, ETC. OF EXISTING WORK WITH EXTREME CARE, AND USING APPROPRIATELY —SIZED TOOLS IN ORDER TO NOT JEOPARDIZE THE STRUCTURAL INTEGRITY OF THE BUILDING C.C. CONDITION OF STRUCTURE: OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITION OF PORTIONS OF THE STRUCTURE TO BE DEMOLISHED. C.D. PARTIAL REMOVAL: ITEMS OF SALVAGEABLE VALUE TO THE CONTRACTOR MAY BE REMOVED FROM THE STRUCTURE AS WORK PROGRESSES IF NOT CLAIMED BY THE OWNER. ALL SUCH SALVAGED ITEMS MUST BE TRANSPORTED FROM THE SITE AS THEY ARE REMOVED. C.E. PROTECTION: ENSURE THE SAFE PASSAGE OF PERSONS AROUND THE NT B DGSITSTRUCTTURES, OTHER FACILITIES IL T ES AND PERSON . REVIEWED FOF D. PROTECTION OF EXISTING CONSTRUCTION. ICODECOMPLIANOE APDPnvpo FEB 17 2011 D.A. THE CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE TO EXISTING STRUCTURE AND SHALL REPLACE OR REPAIR ALL AREAS OF DAMAG D.B. PERFORM CUTTING OF EXISTING CONC AND MASONRY CONSTRUCTION WITH SAWS AND CORE DRILLS. DO NOT USE JACK HAMMERS OR EXPLOSIVES. E. SALVAGED ITEMS: E.A. THE CONTRACT DOCUMENTS INDICATE SPECIFIC MATERIALS THAT ARE TO BE REUSED IN THE FUTURE TENANT IMPROVEMENTS. THE CONTRACTOR SHALL REMOVE, PROTECT, AND REINSTALL THESE ITEMS. E.B. MATERIALS SCHEDULED FOR REUSE WHICH ARE DAMAGED BY THE CONTRACTOR TO THE EXTENT THEY CANNOT BE REUSED SHALL BE REPLACED BY THE CONTRACTOR WITH EQUAL QUALITY MATERIAL AT NO ADDITIONAL COST TO THE OWNER. E.C. REMOVED AND SALVAGED MATERIALS OF VALUE THAT ARE NOT RECEIVE DESIGNATED FOR RE —USE, UNLESS CLAIMED AS SALVAGE BY THE CITY OFWWI" OWNER, EGALLYODISPOS D PROPERTY OF OFF—SITE. TH CONTRACTOR, AND FEB 09 2011 E.D. THE OWNER WILL REMOVE, OR UNDER SEPARATE CONTRACT, HAVE 1T CENTER MATERIALS AND EQUIPMENT WHICH THE OWNER REQUIRES REM 1� PRIOR TO THE WORK UNDER THIS SECTION BEGINS. City of Tukwila BUILDING DIVI,SIMI L: \2010 \10 -175 \CD's \Demolition Permit\ REVISIONS BY W w 4 I— (Cs >— N W (1') x 3 lJ U Z z LU N I (1) a> 1 W U � Z" � m U ° COLUMBIA, CA 95310 w Z I-- V) o 0 Q 0 W r- s 00 O• a_ Q UJ • < 0 =' o � Z Q U O � 0 I- N DEMO, FLOOR PLAN ♦ DRAWN SLW CHECKED TJ B DATE 12/16/10 SCALE AS SHOWN JOB NO, 10 -175 • SHEET A 2 ■ 0 OF SHEETS I 2/7/2011 12:57 PM DEMOLITION CEILING PLAN SCALE: 1/8" = 1' -0" / \I 1 V 1 /\ 1 1 / \ 1 I, \I 1L --y1 1 1 1 1 1 1 5 i I \\ % 1 V 1___11___1_ I\ /I I `V I /\ I / \ I 1/ \I 1___ 1L =.11___1_ 1 1 1 / \I __9 1 1 1 L l 1 1 1 1 1 1 1 1 1 C) C) C) 1 1 1 1 l \ 1 \ 1 \ 1 \ I \I \ 1 `\ \ 1 \ 1 � \I � \I 1 C) 5 - -,1 V /\ I / \ 1 / \I 1 1 \ 1 I \ 1 I 1 \I 1 C) 1 1 1 1 1 1 1 1 0 \\ I \ 1 \ 1 \ 1 1 \ I I ` \1 I ` \I -11----4L- __ L___L== 4L_____ .5 - -1 _ L___L___L_ - -1 1 \ \ I \\ 1 1 \ I I \ 1 \ 1 1 \ I \I I \I \1 1 \I L___ -r I I \/ I 1 \\ /I I V 1 I V /\ I 1 /\ 1 \ I 1 / \ I / \I 1, \I L__Y __9 -r l r` 71 1 \ I\ I v /I /\ I I / \ I/ \! 7 1 \/1 V 1 /\ / \ I / \I I ; T -r 1 1 1 1 I _- 1 ,\ I T 1 I \I c) 1`) C) O O O C) r Q KEYNOTES 0 REMOVE ALL EXISTING CEILING SUPPORT /GRID SYSTEM, CEILING TILES, LIGHT FIXTURES, HVAC SUPPLY AND RETURN REGISTERS, AND ALL ASSOCIATED ELECTRICAL AND MECHANICAL DEVICES. DISPOSE OF SUPPORT /GRID SYSTEM AND CEILING TILES. SALVAGE ALL FIXTURES AND DEVICES FOR POSSIBLE REUSE /REINSTALLATION AS DIRECTED BY THE GENERAL CONTRACTOR. 000000000 EXISTING EXPOSED ROOF STRUCTURE ABOVE EXISTING FLUORESCENT LIGHT FIXTURE TO REMAIN - SEE ELECTRICAL. EXISTING LIGHT FIXTURE TO BE REMOVED - SEE ELECTRICAL AND NOTE 1 ABOVE. FIRE SPRINKLER RISER LOCATION. ROOF ACCESS LADDER, SEE DETAIL ROOF ACCESS HATCH ABOVE. ADJACENT TENANT SUITE - NO WORK. STRUCTURAL SUPPORT COLUMN - SEE STRUCTURAL. VERIFY EXACT LOCATION. EXISTING HVAC SYSTEM REGISTER TO BE REMOVED - SEE MECHANICAL AND NOTE 1 ABOVE, DEMOLITION NOTES (CONTD FROM DRAWING A -1.11 F. PREPARATION: F.A. ERECT AND MAINTAIN WEATHERPROOF CLOSURES ON EXTERIOR OPENINGS F.B. PROTECT EXISTING MATERIALS THAT ARE NOT TO BE DEMOLISHED. PROVIDE ADEQUATE PROTECTION OF OTHER WORK DURING SELECTIVE DEMOLITION TO PREVENT DAMAGE AND PROVIDE PROTECTION OF THE WORK FROM ADVERSE WEATHER EXPOSURE. F.C. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY WITH THEIR REQUIREMENTS. F.D. MARK LOCATIONS AND TERMINATIONS OF UTILITIES. F.E. PROVIDE APPROPRIATE TEMPORARY SIGNAGE INCLUDING SIGNAGE FOR EXIT OR BUILDING EGRESS. G. PROCEDURE: G.A. EMPLOY ONLY SKILLED WORKERS TO PERFORM SELECTIVE DEMOLITION G.B. CUT WORK BY METHODS LEAST LIKELY TO DAMAGE ADJACENT CONSTRUCTION TO REMAIN. G.C. WHERE PHYSICAL CUTTING ACTION IS REQUIRED, CUT WORK WITH SAWING AND GRINDING TOOLS, NOT WITH HAMMERING AND CHOPPING TOOLS. CORE DRILL OPENINGS IN EXISTING MASONRY AND CONCRETE WORK AS NOTED ABOVE. G.D. WHERE SELECTIVE DEMOLITION IS TERMINATED AT A SURFACE OR FINISH TO REMAIN, COMPLETELY REMOVE TRACES OF MATERIAL SELECTIVELY DEMOLISHED, INCLUDING MORTAR BEDS. PROVIDE SMOOTH, EVEN SUBSTRATE TRANSITION. H. DEMOLITION H.A. REMOVE EXISTING CONSTRUCTION AND EQUIPMENT INDICATED ON THE DRAWINGS H.B. DISCONNECT, REMOVE, AND IDENTIFY DESIGNATED UTILITIES WITHIN DEMOLITION AREAS WHERE INDICATED ON DRAWINGS. H.C. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER. PROTECT EXISTING SUPPORTING STRUCTURAL MEMBERS. H.D. LEGALLY REMOVE AND DISPOSE OF DEMOLISHED MATERIALS FROM SITE EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. DO NOT BURN OR BURY MATERIALS ON SITE. H.E. REMOVE MATERIALS AS DEMOLITION PROGRESSES. UPON COMPLETION OF DEMOLITION, LEAVE AREAS IN CLEAN CONDITION. H.F. REMOVE TEMPORARY FACILITIES. H.G. REMOVE, STORE, AND PROTECT MATERIALS, INDICATED ON DRAWINGS, FOR READY REINSTALLATION. I. POLLUTION CONTROLS I.A. USE TEMPORARY ENCLOSURES OR OTHER SUITABLE METHODS AS REQUIRED TO LIMIT THE AMOUNT OF DUST AND DIRT RISING AND SCATTERING IN THE AIR TO THE LOWEST PRACTICAL LEVEL. I.B. COMPLY WITH GOVERNING AUTHORITIES PERTAINING TO ENVIRONMENTAL PROTECTION I.C. CLEAN ADJACENT PORTION OF STRUCTURE OF DUST, DIRT, AND DEBRIS CAUSED BY DEMOLITION OPERATIONS, AS DIRECTED BY OWNER, AND GOVERNING AUTHORITIES. RETURN ADJACENT AREA EVIEWED FOR CONDITIONS EXISTING PRIOR TO START OF THE WORK. (JUDE COMPLIANCE OCT 0,52011 Dl� -o33 FEB 17 all City of Tukwila BUILDING rnviRinM CINOFiUKNAIA FEB 092011 PERMIT CENTER L. \2010 \10 - 175 \CD's \Demolition Permit\ REVISIONS BY UW O P.O. BOX 1134 COLUMBIA, CA 95310 W Z W0 DEMO. CLG. PLAN DRAWN SLW CHECKED TJB DATE 1/7/11 SCALE AS SHOWN JOB NO. 10 -175 SHEET A 3 ■ 0 OF SHEETS 2/7/2011 12;59 PM ■ ALEX SCHEELO 0 N A)( B) 1 2 3 }- C ( D /II/_Ala (E) C21IDENBER (E) RTU -3 0 (E) 0 (E) RTU. y 0 O • DEIR IOLITIOI I MECHANICAL ICAL ROOF PLAN 0 SCALE: I/S V -0" J_ - NORTI -I- ■ DEMOLITION KEY MOTE SCHEDULE 1 OEXISTING AC UNIT ON ROOF TO REMAIN. MECHANICAL CONTRACTOR TO VERIFY EXACT LOCATION. REFER TO KEY NOTE SCHEDULE THIS SHEET FOR FURTHER INFORMATION. ()EXISTING .4C UNIT ON ROOF TO BE RELOCATED TO NEW LOCATION SHOWN, MECHANICAL CONTRACTOR TO VERIFY EXACT LOCATION. REFER TO KEY NOTE SCHEDULE THIS SHEET FOR FURTHER INFORMATION. ()EXISTING ROOF MTD CONDENSING UNIT TO REMAIN. EXISTING ROOF MID CONDENSING UNIT, PIPING, ELECTRICAL AND SUPPORTS TO SE REMOVED. PATCH, REPAIR AND PAINT ROOF TO MATCH EXISTING °EXISTING ROOF MTD EXHAUST FAN TO BE REMOVED. REFER TO MECHANICAL FLOOR PLAN FOR REPLACEMENT INFORMATION. MECHANICAL CONTRACTOR TO VERIFY EXACT LOCATION. REFER TO MECHANICAL ROOF PLAN Ti-os Ti-o SHEET FOR FURTHER INFORMATION. OCT. 0 5 2011 033 EVIEWED F CO h COMP • ' CE AD FE till ity of Tukwil UILDIN( nivisinn F PARATE APp MITgNQ RED AMA FEB 09 2011 PERMIT CENTER ALEXANDER SCHEFLO and ASSOCIATES, Inc. Mechanical Engineers (209) 948-9761 2926 Pacific Ave. Stockton, Ca. 95204 REVISIONS 1 BY J COLUMBIA, CA 95310 DEMO & NEW ROOF PLAN f DRAWN M. GLATZ 1 CHECKED M. SCHEFLO DATE 01-28-11 SCALE AS SHOWN JOB NO. 11-247 SHEET AA - Al • 0 OF SHEETS .1 ALEX SCHEFLO 0 c0 O N M 0 r r .11 11 11 11 11 11 is 111 111 111 111 L L r t-� 1 J n 11 11 11 u n It .1 11 1 1i1, 11 1I 11 I1 11 11 11 11 11 I1 11 11 1 1_ 11 11 11 11 11' 11 11 11 11 11 11 11 4 ri m 1 1 11 11 11 , 11 11 11 11 1 I1 1i 11 , L1 0111 1 1 r--iii---1 i '- "7 1 I 411, 1 C) lil i I ? fail; f� s r 11 11 11 11 N r1 1 11 fl II 11 11 11 11 11 II 11 11 11 11 11 II 0, --4 11 4✓ 11 11 11 11 I IL Ir 11 ,i If I, I, 4 11 1' 1 n 11 11 11 11 11 11 11 11 11 11 11 11 11 Ii I1 II 11 11 1I ,1 it 11 11 11 it I1 11 11 11 11 , 11 11 I1 11 11 11 11 1 11 11 11 1 1J 1 DEMOLITION PLUMBING PARTIAL FLOOR PLACE SCALE: 1 /6" =1' -0" (2) (3> {4) (s) `c ) �B) (E) RTU 00 14 Lcd L (E) Rfli -2 141 DSO %L J L(E) RtU -4 �-- (E) R 11 -3 (E) RTU -$ (E) R1U -'1 (c) -NORTH- erA DEMOLITION PLUPABONG ROOF PLAN VP SCALE: V16 "31' -0I' SEPARATE PERMIT AND APPROVAL REQUIRED -NORTH- (' PLU CMG DE, . I 0 I;{Elf NOTE TL SCHL DULL 10 REMOVE PLUMING FIXTURE SHOWN CROSS HATCHED AND CAP ALL SERVICES BEHIND FINISHED SURFACE. 0 REMOVE (E) GAS PIPING ABOVE FINISHED ROOF TO AC UNIT. ALSO REMOVE GAS PIPING BELOW ROOF WITHIN AREA OF VAULT. PLUMBING CONTRACTOR SHALL REPIPE GAS AS REQUIRED TO AVOID AREA OF VAULT AND KEEP SERVICE TO OTHER EXISTING AC UNIT'S "HOT". 0 DISCONNECT (E) GAS FROM (E) UNIT AND REFER TO PLUMBING FLOOR PLAN FOR RECONNECTION TO RELOCATED AC L114IT. 0 REMOVE (E) CONDENSATE TO UNIT THAT IS BEING RELOCATED. 18 DISCONNECT (E) CD FROM (E) UNIT AND REFER TO PLUMBING FLOOR PLAN FOR RECONNECTION TO RELOCATED AC UNIT: OCT 052011 11 -033 PLUMBING DEMO GENERAL INOOTE3 1. FIELD VERIFY EXACT LOCATION OF ALL EXISTING UTILITIES WITHIN THE EXISTING AREA TO BE RENOVATED PRIOR TO 1310 ,4 ND CONSTRICTION. REWORK, REROUTE, OR RELOCATE MY EXISTING UTILITIES AND 01=F3ETS IN CONFLICT WITH THE NEW PLUMBING SERVICES. COORDINATE BETWEEN TRADER PRIOR TO INSTALLATION. BIKE & MI N CLER DEMOLITION KEY NOTE RTE SCHEDULE 0 EXISTING BUILDING HAS A FIRE SUPPRESSION SYSTEM FIRE SPRINKLER CONTRACTOR TO PROVIDE REQUIRED DEMOLITION OF EXISTING SYSTEM TO ALLOW FOR INSTALLATION OF UPDATED SYSTEM THAT WILL MEET THE REQUIREMENTS OF THE NEW TENANT IMPROVEMENT. REFER TO SHEETS F2.0 4 P2.1 FOR FURTI4ER CLARIFICATION ON EXISTING FIRE SPRINKLER SYSTEM. ALEXANDER SCHEFLO CITYOFTUKVNLA► and ASSOCIATES, Inc. FEB 0 9 2011 Mechanical Engineers (209) 948-9761 2928 Pacific Ave. Stockton, Ca. 9520 'ERMIT CENTBR ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ENGINEER AND THE SAYE MAY NOT BE USED, DUPLICATED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. ® Alexander Schello & Assoc., Inc J r REVISIONS BY 1 W W Z U o p c” ce 0 J zQ 0 W ppU� zo o COLUMBIA, CA 95310 < 1.1.1r- se 00 a. W r0 <C o N ~ DEMO FLOOR /ROOF PLAN r DRAWN ~ S. PRUITT CHECKED M. SCHEFLO DATE 01 -28 -1 1 SCALE AS SHOWN JOB NO. 1 1 -247 '4 SHEET P...1 .0 OF SHEETS 1 1 REMOVE EXISTING 480 VOLT PANEL 75 KVA TRANSFORMER AND 208 VOLT PANEL. EXISTING METERS TO REMAIN IN SERVICE AND CONNECTED TO NEW PANELS. ABANDON EXISTING 480 VOLT :0 PANEL, 45 KVA TRANSFORMER AND 208 VOLT PANEL REMOVE ALL EXISTING LIGHTING OUTLETS, COMMUNICATION OUTLETS, ETC FROM TI SPACE El) DEMOLITION ELECTRICAL PLAN ESCALE: 1/8" = 1' -0" GENERAL NOTES 1. the contractor shall remove such existing work as called for on the drawings or as required to clear the areas for new construction. *where existing equipment is to be retained /relocated, extreme care shall be taken to prevent damage during the removal and reinstallation. where damage occurs, the equipment shall be replaced or repaired to the satisfaction of the architect, at no additional cost to the owner. 2. all equipment and material removed that is not being reused shall remain the property of the owner and shall be stored or disposed of as directed. 3. remove existing electrical and special systems wiring devices shown dashed or (acted within dashed areas unless noted otherwise. for all removed devices, remove associated wiring /cabling and raceway from device to source unless required to maintain service to devices in adjacent areas. it is the electrical contractor's responsibility to field verify existing branch wiring circuits to be removed and reused. 4. empty backboxes installed within cmu or concrete walls shall be provided with blank coverplates. 5. existing panelboard cabinets to remain shall not be used for other purposes than circuit protection and distribution points and shall not be used as junction or pull boxes. 6. where existing electrical work interferes with new york and where such installations are to remain in use, the installations shall be disconnected, relocated, and reconnected to coordinate with the work indicated within the contract documents. such devices shall be restored to their original operating condition. (e) UNIT TO BE REMOVED. DISCONNECT & SEAL PENETRATIONS (e)CONDENSER (e)CU (e)RTU -1 (e)RTU -2 (e)RTU -3 (E)AC UNIT TO BE DISCONNECT RELOCATED BY THE MECHANICAL CONTRACTOR, RECONNECT TO NEW CIRCUIT SHOWN BY THE ELECTRICAL CONTRACTOR (e)RTU -4 (e) UNITS TO REMAIN BUT RECONNECTED TO NEW PANEL. SEE MECHANICAL CONNECTION PLAN FOR NEW CIRCUITING (e)EF -1 (e)EF -2 (e)RTU -5 (e) RTU -7 (e) UNIT TO BE REMOVED. DISCONNECT & SEAL PENETRATIONS (e) UNITS TO REMAIN BUT RECONNECTED TO NEW PANEL. SEE MECHANICAL CONNECTION PLAN FOR NEW CIRCUITING (E)AC UNIT TO BE DISCONNECT RELOCATED BY THE MECHANICAL CONTRACTOR, RECONNECT TO NEW CIRCUIT SHOWN BY THE ELECTRICAL CONTRACTOR DEMOLITION MECHANICAL ROOF PLAN SCALE: 3/32" =1'-0" OCT 0 5 2011 1 � 033 SEPARATE PERMIT AND APPROVAL REQUIRED cirroREMLA FEB 0 9 2011 PERMIT CENTER 1 K: \2011 \0 - 100 \CA WashingtonTwo \Sightline Electrical.rvt ELECTRICAL DEMOLITION PLAN r REVISIONS 1 BY J P.O. BOX 1 134 COLUMBIA, CA 95310 0 W z H U W F- U uJ Z • -, W ,- s c0 {.l. I..L W > Q O=1 0 Z < 0 O � O I- DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 2 SHEETS