Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-058 - REISCHLING PRESS - STORAGE RACKS
REISCHLING PRESS 3311 S 120 PL Di 1-058 City oNukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TIIKW Suite No: Project Name: REISCHLING PRESS INC DEVELOPMENT PERMIT Permit Number: D11 -058 Issue Date: 03/29/2011 Permit Expires On: 09/25/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98057 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET , RENTON, WA 98055 Contractor License No: NORTHWH275JF Phone: 206 - 818 -4488 Phone: 206 255 -0500 Expiration Date: 10/09/2011 DESCRIPTION OF WORK: INSTALL (8) BAYS OF USED RACKING. SEE ATTACHED SUPPLEMENT, DRAWINGS AND ENGINEERING FOR COMMODITY, SPECIFICATIONS, LOCATION AND SPRINKLER INFORMATION. Value of Construction: $0.00 Fees Collected: $212.40 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0010 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11 -058 Printed: 03 -29 -2011 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. /� Signature: Print Name: Date: 37.2- c7 /�cD r/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet doc: IBC -7/10 D11-058 Printed: 03 -29 -2011 in height shall be anchored or braced to prellk overturning or displacement during seismigmlients. The design and calculations for the anchorage or bracing shilgre prepared by a registered professional enlipbr licensed in the State of Washington. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 13: Maintain fire extinguisher coverage throughout. 14: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinlder density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 17: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 19: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -058 Printed: 03 -29 -2011 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No. 1 t (—Ogg Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION �/ King Co Assessor's Tax No.: /O� 30'1 - `jC 6 % Site Address: 3 3 1 ,5: I do 6 / p L- - —9< /6 0 Suite Number: Floor: Tenant Name: R2 I -Sy.Lh I l �Q fra s S 2■►C - J D Property Owners Name: Art get ha a ., J ��;; `, _ ?/1168 Mailing Address: I a-a0 J T 4-& ,?4 ferl'IGT,�',a i �/hc. L /1' J /' 77476.-, (G, 1c/A City State Zip New Tenant: ❑ Yes CONTACT PERSON - -who do we contact when your permit is ready to be issued Name:► c>0re"S0,N Mailing Address: 1100 57 i/V. s 11/ E -Mail Address: V� S 0 r-e" 30/1 C w hs, �pvr► Day Telephone: 6- Rf g- K g g %7.c?,, „ rA+ 9 )eg 7 City State Zip Fax Number: Li a.„5"-- a. 8/- 64YG GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 4/0f41 1/VieS%/ �nd /ice JZS)42.1"^Ns Mailing Address: // O 0 S W 7g- c.--T Contact Person: ,,,A7/lite- E-Mail Address: 01,S Oyer -ran (id /A S . Co,� -► Contractor Registration Number: 4/0,--1-144 tt/ 4 7c SF .2..c- .1� G(/..7 76-0s-7 City State I ` Zip Day Telephone: �O ^ tole" ii LfSi R Fax Number: Expiration Date: / d 79 /c 1/ ARCHITECT OF RECORD - All plans must be. stamped by Architect of Record Company Name: Mailing Address: Contact Person: ddress: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record /' Company Name: G de - e75�(rj►n iA,o� r' i Mailing Address: L(1 aZ- 1/t/ r� ✓r'Da�G„ *day,/ Contact Person: 6zif-7 044-1 r ree. 0 ec GQ ? /moo 5/ City State Zip Day Telephone: 8/8 ?Yd 3g/ E -Mail Address: Fax Number: gig aid 3g73 H:\Applications \Forms - Applications On Line\20I0 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATIO1 – 206 - 431 -3670 Valuation of Project (contractor's bid price): $ /7 g / `Existing Building Valuation: $ Scope of Work (please provide detailed information): 7/1 Std it CO i3Q.c .3 e/ 4f /fit C�t r4 Cif; r .$, kC! /.-P■rl !/I rr&, – /1l ‘rPs.kO1 OW/G/1 5272 Will there be new rack storage? [es ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes DeVNo If `yes ", explain: FIRE PROCTION/HAZARDOUS MATERIALS: L/ —d'/ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ��No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport' Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes DeVNo If `yes ", explain: FIRE PROCTION/HAZARDOUS MATERIALS: L/ —d'/ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ��No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 • • PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHOR D AGENT: Signature: //-- Print Name: ��/ e_ �>D/ ��o •� Mailing Address: / / 00 $ WI/ 7 d3 S-T Date: 5 /3 /oZU l/ Day Telephone: ,7-06 9l ?` 7 f 0104,/7 , tT,- 9rc - -7 City State ,Zip Date Application Accepted: "Z � l Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7.2010 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: REISCHLING PRESS INC RECEIPT Permit Number: D11 -058 Status: APPROVED Applied Date: 03/08/2011 Issue Date: Receipt No.: R11 -00612 Initials: User ID: Payee: JEM 1165 Payment Amount: $130.50 Payment Date: 03/29/2011 10:20 AM Balance: $0.00 MICHAEL J SORENSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 02509C ACCOUNT ITEM LIST: Description 130.50 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 126.00 640.237.114 4.50 Total: $130.50 doc: Receiot -06 Printed: 03 -29 -2011 411 111 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: REISCHLING PRESS INC RECEIPT Permit Number: D11 -058 Status: PENDING Applied Date: 03/08/2011 Issue Date: Receipt No.: R11 -00445 Payment Amount: $81.90 Initials: WER Payment Date: 03/08/2011 02:45 PM User ID: 1655 Balance: $130.50 Payee: MIKE SORENSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 094417 ACCOUNT ITEM LIST: Description 81.90 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 81.90 Total: $81.90 doc: Receiot -06 Printed: 03 -08 -2011 _; I: "•..: _ .,art:.,4 raar.•a so-- :sr- }v .. ,.� • INSPECTION. RECORD' Retain a copy with permit . // -05 ' PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro Act: Type of Inspection: Address: 3,3 // 5 iaza PG Date Called: t Special Instructions: Date Wanted: 3— 3 / —// a.m. Requester: Phone - 649- 'VI 1Xlsi Approved per applicable codes. Corrections required prior to approval. CO MENTS: r»»Ai►•t kJ 6 — 4rpteVeZ Ca) 4rM:f(fie -No!) Ids /r ",x ei AC Date: r INSPION FEE r to next inspection. fee must be paid at 6300 Southcenter Blv Suite 100. Call to schedule reinspection. 1 "1 7 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit #0// -a55, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: pR r Sprinklers: Hrs.: / Type of Inspection: Address: 3 311 Suite #: 14't 5 / 2' P1 . Contact Person: Special Instructions: Permits: -Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 12,4(.4 ,F.,1 C. r,,14 Needs Shift Inspection: Sprinklers: Hrs.: / Fire Alarm: Hood & Duct: / Monitor: Pre -Fire: Permits: -Occupancy Type: , Inspector: fill r 3 Date: 3J3 j 11/ Hrs.: / fX $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete M a s o n r y A s p h a l t R o o f i n g P i l i n g S t e e l S o i l s W o o d March 31, 2011 O Jam.. atv 4 File: 11 -150 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit No.: Reisch 'n 1 S. 1 D11-058 Press Inc. `h Place Suite 160 A.A.R. TESTING LABORATORY, INC. CONS1 RUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Avid-kr4 giithes)— Kimberle Anderson President CC: Northwest Handling Systems, Inc. -Thom Drew, Mike Sorenson Tel: (425) 881 -5812 Fax: (425) 881 -5441 e 7126 180th Ave. NE . P.O. Box 2523 * Redmond, WA 98073 Client: North West Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055 Contact: Thom Drew Field Report Report #: 52248 Project Number: 11 -150 Permit #: D11 -058 Project Name: Address: Reischling Press Inc. 3311 S. 120th Place Suite 160 Inspection Performed: Proprietary Anchors Date: 3/30/2011 Time: Temperature: Verified anchors to be Hilti KB -TZ 1/2" x 4 1/2" wedge type. Verified hole cleanliness and minimum embedment of 3 1/4 ". Torque was tested with calibrated wrench #132B and was found meeting or exceeding manufacturer's recommendations of 40 ft. lbs. All work was found in conformance with approved plans, manufacturer's recommendations and ESR #1917. All racking noted on D -1 of plans as "racks for permit" were inspected at this time. Distribution: d] Distribute Client '"--j Distribute Engineer kj Distribute Municipality r ] Distribute Architect L 1 Distribute Contractor ] Distribute Owner ] Distribute Other 1 Distribute Other Inspector: Chandler, Loren Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden NORTHWEST H A N D L I N G SYSTEMS, I N C. The Material Handling Experts FILE COPY Permit No. 1100 SW 7th St Renton, WA 98055 (425) 255 -0500 ph (425) 228-6946 fax ATTENTION FIRE AND BUILDING DEPARTMENTS RACK INFORMATION SUPPLEMENT REVIEWIU FOR CODE COMPLIANCE A MMVED SITE ADDRESS: 3311 S. 120th PL #160 TENANT NAME: Reischling Press, Inc. DATE: March 3, 2011 APPLICANT: Mike Sorenson / (206) 818 -4488 1. Load application and rack configuration drawings attached. hit i n LJ,I City of Tukwila BUILDING DIVISION 2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Flattened cardboard on wood pallets directly on rack with open wire mesh decking. No shrink wrap, non encapsulated. 6. Sprinkler System Information: .39 gpm over 5600 sq. feet. 7. Smoke and heat vents: In place, but not required for square footage of racking (under 12,000 square feet). 8. Building egress and exits indicated on attached drawings. b\1O56 RECEIVED MAR 08 2011 PERMIT CENTER BY G. GHANIAN DATE 3-2-11 SUBJECT RAdK DEOI(dN Sc ENcINEERIN(t do. 412 WEST BROADWAY, SUITE #204 dLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO. 1 JOB NO.. RD -15354 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: REISCHLING PRESS, INC. 331 1 SOUTH 120th PLACE, #160 TUKWILA, WA. 98168 PER IBC 2009 EDITION SECTION 2208 STORAGE RACKS CAPACITY: 3000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -15354 FILE COPY Permit No. EXPIRES 12 -26 -11 bUO58 REVIEWED FOR CODE COMPLIANCE ArsonnvEn MAR 18 2U11 City of Tukwila BUILDING DIVISION RECEIVED MAR 08 2011 PERMIT CENTER BY G. OHANIAN DATE. 3 -2 -11 SUBJECT RAdK DE$I(N & ENdINEERIN(4 do. 412 WEST BROADWAY, SUITE #204 dLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 2 JOB NO.. RD -15354 O co BEAM 144" 1 1 SEISMIC DESIGN S Ds xl V Rx1.4 )641 SDs =1 FRONT VIEW I x=3.22 Sx =1.23 F Y= 55 KSI. 44" 1 44° LOAD PER BEAM + 25% IMPACT LOAD (3Kx.88) +(1.5Kx.25) = = 1.5K 2 BEAMS M= 82 =27 "x S R= .82 <1.23 _ 5xw"4 L 384.1x .E =.61"< 180 =•80' IBC 2009 (SEC. 2208), RMI SPECS. ASCE 7 -05 (SEC. 15.5.3) (USGS WEB SITE, "SITE 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED W =D.L.+ 3 PALLET LOAD LOAD PER COL. P =.2DL+ (4.5Kx. = 3x3.0 K =4.5K 2 COL 75) =3.6K W =.2DL+ (4.5PLx. V = .38 K LONGIT. = 'S7 K TRANS. 67) = 3.2 K CLASS D ") LONGIT. SEISMIC 44" SIDE VIEW Conterminous 48 States 2009 International Building Code Latitude = 47.4954 Longitude = — 122.29120000000002 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D — Fa = 1.0 ,Fv = 1.5 Period So (sec) (g) 0.2 1.497 (SMs, Site Class 0) 1.0 0.774 (SM1, Site Class 0) Conterminous 48 States 2009 International Building Code Latitude = 47.4954 Longitude = — 122.29120000000002 Design Spectral Response Accelerations SDs and SDI SDs = 2/3 x SMs and SDI = 2/3 x SM1 Site Class D — Fa = 1.0 ,Fv = 1.5 Period So (sec) (g) 0.2 0.998 (SDs, Site Class D) 1.0 0.516 (SDI , Site Class 0) .38 K 11 "K 5 •K 9 "K 11-K BY G. OHANIAN DATE. 3 -2 -11 SUBJECT RACK DEOIGIN & ENdINEERINc CO. 412 WET BROADWAY, �1UITE #204 LENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 3 JOB NO.. RD -15354 COLUMN ANALYSIS x- 3" - — x F=55 KSI Ae =.78 Ix =1.19 Se =.8 r, =1.2 ry =1.1 COMBINED STRESS RATIO Pex= (2 =33 Oc =1.8 QcP — Ob =1.67 ax =1— .80 Pex — Cmx =.85 BASE PLATE ANCH. TENSION = .03 K ANCHOR SHEAR = .19 K KL= 60_7 -85 x KL_52 _ ry — 1.1 — 47 Mn =Se .Fy =44 t)P.P+ (2b.Cmx.M =.71<1 n n• a (2)-1/2"0 HILTI KWIK BOLT —TZ ANCHORS PER BASE PL., 3" EMB. ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.09x1x65 =3 K BEARING CAPACITY OF COL. HOLE 7/16 "0 RIVET A = .1 Fy = 79 KSI Pa = .1x79x.4 = 3 K Ma = (3 Kx4 ") +(1.5 Kx2 ") =15 CONN. M END = .01 x W 12= 2 "K M— 10 "K M— 12 "K SEISMIC TOTAL "K 3 PIN CONN. 2 Fe= 7T KL)2 =40 rx 2 Fn =Fy (.658 Ac ) =31 KSI Pn= Fn .Ae = 24 K Ac= JFy /Fe = 1.17 Ac <1.5 7 3/4 "x5 "x3/8" BASE PLATE 10 "K I 6- " I 7 3/4 10 "K BY G. OHANIAN DATE . 3-2-11 SUBJECT RAdK DEOI(N & EN(dINEERIN( do. 412 WET BROADWAY, QUITE #204 LENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO, 4 JOB NO.. RD -15354 OVERTURNING 3.6K 36K . MOT = .57Kx2 x208 °x.66 =156 "K x�J COL. MR = 3.6 Kx44 "= 158 "K NO UPLIFT LOAD TO DIAGONAL P = .57 Kx OL 44 = 1.5 K FY =55 KSI Ae =.26 rx =.48 Q =.74 L= 58" Pa = 2.5 K CHECK WELDS pn= (1 .01L)L.t.Fu =5.36K 0= 2..55 = 2.1Kx2 =4.2K SIDES CHECK SLAB 3600 — 3 60' 1000 — .57 K 3.6x144=518 °" 518 =23" M= ( = ) 2 x 1000x 2 LI- x12=1260 "# s= 1\2x62 = 72 6 1260 = 18 <1.6V'2500 =80 72 44" a .57 K 10 0 N 10 TOP LEVEL LOADING W= .2DL +1.5 L�1.7 K LOAD PER COL. V= .30 K MOT= .30Kx2 x184 " = 110 "K COL MR = 1.7Kx44 "= 74 "K UPLIFT = 110-74 = 82 K 44" BOTH SIDES TYP. 1/2,, t =.07" 360011E 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL • PE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -058 PROJECT NAME: REISCHLING PRESS INC SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 03 -08 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ti l ,,9 UK. 11 ul ding 'vision Fire Prevention Public Works n Structural Planning Division ri n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 03-10-11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 14. Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 04 -07 -11 Approved with Conditions Nr Not Approved (attach comments) ri REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentslrouting slip.doc 2 -28 -02 Contractors or Tradespeople liter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name NORTH WEST HANDLING SYS INC UBI No. 600051641 Phone 4252550500 Status Active Address 1100 Sw 7Th St License No. NORTHWH275JF Suite /Apt. License Type Construction Contractor City Renton Effective Date 4/6/1973 State WA Expiration Date 10/9/2011 Zip 980552939 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES J Cancel Date 01/01/1980 Amount THOMAS, KEVIN A 30 01/01/1980 ADV4015483385 KOSTY, CLARK R 10/01/2011 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 TRAVS 81S103354822BCM 10/01/2001 Until Cancelled $12,000.00 10/09/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 30 NATIONAL FIRE ADV4015483385 10/01/2010 10/01/2011 $1,000,000.00 09 /20/2010 29 ACE AMERICAN INS CO PMDG24651605002 10/01/2008 10/01/2010 $1,000,000.0009 /30/2009 28 ACE AMERICAN INS CO PMDG23858769 10/01/2007 10/01/2008 $1,000,000.00 09/28/2007 27 ACE AMERICAN INSURANCE COMPANY PMDG22904279 11/01/2006 11/01/2007 $1,000,000.00 10/27/2006 26 BURLINGTON INS CO HGL0011190 11/01/2005 11/01/2006 $1,000,000.00 11/04/2005 25 BURLINGTON INS CO HGL0007660 11/01/2004 11/01/2005 $1,000,000.00 11/01/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 03/29/2011 180' 60' 60' 94'- 4" 60' 59'-8" H 'dr .4- 0.13198110. • Ct. H RACKS FOR ;777., .979:1:9; .3.5111171 EXIT EXIT EXISTING RACKS ■=62.011124 24' -6" i EXISTING kAcKs EXISTING RAC <S 24'-6" 125' LXIT • 24'- 6" EXISTING FENCE 11'-7 3/8" (ADJACENT TENANT) EXISTING RACKS Pi 4N -1T-4,W NORTH SC '_6"= l' • 47711=6""N=. • ;•-t,„ 139511=1131WEIIIII=1 7A,,,,ttcw.p.cttUttC:Bict-tttc-t,tt-. 'cvccv ccd ' • . • • v ..!•Me•c;.0.-X • .'"Vccv ••- cv! 1 NORTI I Attc','c'tc.Act ' 111111111111111111Ei rrii r 1 -;.-•,-t'tr,•,,,L1I 7 ttf, .• • .,',-, .44" • gotottO ,AA A AO 1,:VCALASIOW• cAV 04000. c4, 13' - SEPARATE PERM REQUIRED FOR errAethanleal 111.0•1m1-11. EirPlumbing Wias Piping of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will requir a new plan tmibmithal iniude iaptanrevewfer . :1.E COPY Pen,* No. o 59 Plan MAN approval is subject to errors and omissions, hipproval of contrition documents does not authorize ieic violation of any adopted code or ordinate. Receipt of approved Field Cpy,aroondWons is acknowledged • ..,. BY - "E aty Of lirkwIla BUILDING DIVISION aiN1 SHEET NUMBER CODE COMPLIANCE Ammewpo MAR I 8 an ) • qityotTukvAla J.) BUILDING DIVISION r.L.ArEIVED MAR 08 2011 PERMIT CENTER 0 a_ 0 (1) IJ Lu 00 < z w < < z cc 0 < , OCLI.1.1>— ._ (1) (1) z 0 DRAWING NUMBER , TYP ,. i•iI) 1 3/4" , a )T; 1, 8 o ��� 01 P ® ® - , ,,ze >., co c� 1 , . N.. ,`,\G�'. ,, 1. i ,.., '\ 4 h 0 ao vs , ... ,... 1, r Vii% / sx loin I I I t I \ cri I_ .` ' BOTH SIDES TY*i/8 ETIY V1.5 „\ \ / -1 1 • rl I i fit► q; / i •/' °c-4 )( - -� t= 01.07" i i I / �� 1� ti N SA Op # bCk ACI . l'IN 1 ! - 1/8 • _dada 0 E 0 J Id 0I - t =.o7" A SEC. A —A Ir) s `r ( - / • TYP ,. rte. a tr ' •' 'O = d . , .a' , a ' = ' • , a ; ° M t =.09" i 1 i1 11 ll ii 1/8 X1.5" / / I O 0 N — _ , • ... d' • • e' °', . • ° , Q ° ea; ..e �.. A e '� ° r - - - -_ _ -_,� I ' r V \ I O . , N 6" t =3/8" T � • ' � 7 3/4" - - - - -- - - -- - SEC. B--B 7/16"0 RIVET ° •/ / (2)-1/2"0 ANCHOR BOLTS PER BASE PLATE 3" EMB., (SEE NOTE NO. 4) ASTM A576 -90B HOT- WROUGHT UNS ;, t =3/16 G10100 GRACE C -1010 BASE PLATE DETAIL 1 BRACING DETAIL 2 BEAM CONNECTION 3 ROW SPACER � r e r ° 1 0 r n 0 n r n n r r / ✓ ► e0r 0Qr e °Qrr 0120 0 °Qr 0Qr °Qr eQr ► r eQr eQ e4r e .,9 u °r a • / r O 17 r rr r r r r r j l P . 11 01 , I 0120 °120 e 0 012 0 09 0 °a4 0 ►.1212 j0 °0 °40 0124 ° °40 0412 0120 • 0 0 0 0 12 0 ° 0 4 12 Qr Q 12 12 r0 0 12 ri r �� iOS8„r 8 GENERAL CONFIGURATION . J _ . 144" 44" 44" 44" NOTES: 1- DESIGN OF STEEL STORAGE RACKS AND CALCULATIONS ARE IN COMPLIANCE OF THE INTERNATIONAL BUILDING 2 -STEEL FOR ALL SHAPES FY =55 3 -NO FIELD WELDING IN THIS PROJECT OF THE APPROVED FABRICATOR 4 -ALL ANCHORS HILTI KWIK BOLT SPECIAL INSPECTION IS REQUIRED 5- CONCRETE SLAB 6" THICK 2500 6- STORAGE RACK CAPACITY 3000 7 -RACK INSTALLATIONS SHALL DISPLAY A PERMANENT SIGN OF 50 SQUARE OF THE RACK (3000 #/ LEVEL) 8- STORAGE RACKS SHALL BE INSTALLED VERTICAL OF 1/2" IN 10' -0" OF 9 -THE CLEAR SPACE BELOW SPRINKLERS BETWEEN THE TOP OF THE STORAGE 10- STORAGE RACK AREA NOT OPEN - AS SHOWN BY WITH THE CODE 2009 EDITION, KSI. ASTM A1011 ALL WELDED #00777 (E70XX ELECTRODES) -TZ ESR -1917 PSI. SOIL BEARING #/ LEVEL IN ONE OR MORE INCHES IN AREA, WITH A MAXIMUM HEIGHT SHALL BE AND THE CEILING TO PUBLIC, EMPLOYEE .� REVIEWED FOR CODE COMPLIANCE Apo»nven MAR 18 2011 City Of Tukwila RU1LOINr IIIVISInN THESE REQUIREMENTS GR.55 CONSTRUCTION A DRAWINGS SECTION 2208 (EXCEPT AS NOTED) IN THE SHOP CAPACITY 1000 PSF CONSPICUOUS LOCATIONS SHOWING THE CAPACITY TOLERANCE FROM THE MINIMUM OF 18 INCHES SPRINKLER DEFLECTOR, ACCESS ONLY RECEIVED MAR 08 ZV 1 PERMIT CENTER . .. . 1 © Q t .— \ co f - �\ i i cv co r \ t rs_ \ N �, 1 N ... : 3 cNO r ,i N 0, rte, 0 co �� � \ O N `� ` 1641 d I 0 N `� O �10A 4`" °� WA r�jy �c. RACKDESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 i 00'c — •..► —, �� ���� ti - Cil SCALE: NONE DRAWN BY: _4S/! (1 r \ \ t :::7777,:..:•!.'..; •' :,r :.1 ,'•' • / ,• t'Y e. . :4'.'....•', Y • 7• �. . 'a• .. DATE: 3 -2 -11 .., tii 111 . _• .. ._ - / 4,� 99552 � � •, S ��• PROJECT: REISCHLING PRESS INC. 3311 SOUTH 120th PLACE, #160, TUKWILA, WA. 98168 , • FRONT VIEW SIDE VIEW G�� L 04.. : STORAGE RACK DETAILS JOB No. RD -15354 SHEET NO 1 OF 1 EXPIRES 12-26-11