Loading...
HomeMy WebLinkAboutPermit D11-066 - CASTILLO RESIDENCE - REMODELCASTILLO RESIDENCE 14011 MACADAM RD S Di 1-066 City dikTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1523049035 Address: 14011 MACADAM RD S TUKW Suite No: Project Name: CASTILLO RESIDENCE DEVELOPMENT PERMIT Permit Number: D11 -066 Issue Date: 04/19/2011 Permit Expires On: 10/16/2011 Owner: Name: FED HOME LOAN MORTGAGE CORP Address: POB 650043 , CARROLLTON TX 75265 Contact Person: Name: JUN CASTILLO Address: 13355 56 AV S , TUKWILA WA 98178 Phone: 206 - 948 -6045 Contractor: Name: OWNER AFFIDAVIT - JUN CASTILLO Phone: Address: Contractor License No: Expiration Date: DESCRIPTION OF WORK: REMODEL OF HOUSE. Value of Construction: $15,000.00 Fees Collected: $996.40 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11 -066 Printed: 04 -19 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: RJ2_ Date: L''le"— 4 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: --1.K (R6k Date: This permit shall become null an if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IBC -7110 D11 -066 Printed: 04 -19 -2011 7: All electrical work shall be inspected an ' proved under a separate permit issued by t ity of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -066 Printed: 04 -19 -2011 CITY OF TUKA Community Develo7nent Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Buil ding Pe No. b[1-....0 (0 co Mechanical Permit No. fr ( Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: ea di Property Owners Name: JIAYI cI r1�0 Mailing Address: X 3 3 A k & An 140 l l Maul v h CAS ,TulGwi 6 l / King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No ICI. 3 o3 City (A14 ig8 Zip State CONTACT PERSON — who do we contact when your permit is ready to be issued Name: JC (asti Flo Mailing Address: 1335 i vau_6 Day Telephone: E -Mail Address: j cc66110 e, tad • COY►' City Za, C14. k 6o45 State IgRe Zip Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doe Revised: 7 -2010 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATIO- 206- 431 -3670 Valuation of Project (contractor's bid price): $ 15k Existing Building Valuation: $ } Scope of Work (please provide detailed informatio i. : ( See ,Ietd rmi,odit( �i Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ▪ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1't Floor tog y- -e-- 2`d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ® No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ▪ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — icable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE §AME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Jul Cadi Igo Mailing Address: 133bb VC( i ✓o IDate Application Accepted: Day Telephone: TvY -w114 City Date: 3119111 2tiv -4 &tg'6w - LLA State gelql Zip Date Application Expires: Staff Initials: H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1523049035 Address: 14011 MACADAM RD S TUKW Suite No: Applicant: CASTILLO RESIDENCE RECEIPT Permit Number: D11 -066 Status: APPROVED Applied Date: 03/14/2011 Issue Date: Receipt No.: R11 -00758 Initials: User ID: Payee: WER 1655 Payment Amount: $753.10 Payment Date: 04/19/2011 02:46 PM Balance: $0.00 JUN CASTILLO TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04532C ACCOUNT ITEM LIST: Description 753.10 Account Code Current Pmts BUILDING - RES STATE BUILDING SURCHARGE 000.322.100 748.60 640.237.114 4.50 Total: $753.10 doc: Receipt -06 Printed: 04 -19 -2011 CM of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R11 -00488 Initials: WER Payment Date: 03/14/2011 User ID: 1655 Total Payment: 243.30 Payee: JOSE CASTILLO JR SET ID: 041311 SET NAME: CASTILLO SET TRANSACTIONS: Set Member Amount D11 -066 243.30 TOTAL: 243.30 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 243.30 TOTAL: 243.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - RES 000.345.830 TOTAL: 243.30 243.30 INSPECTION RECORD Retain a copy with permit D i t— 0(0 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: T ((0 �n�_ C • Type Inspection: f\ Address: Mj � c) t4 t ke-A4A- AI Date Called: f� ', Special Instructions: ,Q Qik Date Wanted:. Vim. .4 (— /O- If m Requester: Phone No: ?,D Co - 4'4 g -(0045 .Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: /=■it' iP((2)--r • Inspect r: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS PEC ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IL. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: CIASiILL() 1ZfS• Type of Inspection: �xtvAL_ Address: Date Called: Special Instructions: Date Wanted:. c'-2_.G- II a.m. ' n'3 Requester: Phone No: Z.C.' - r'1L4 ta, — C-0',`5 ❑ Appr.oved per applicable codes. "®,corrections required prior to approval. COMMENTS: C__(,4 PmR " Al-90 Oleo c,, r P Date: (,.,NSA -� Ajn Z6— V PECTION FE REQUIRED Prior to next nspection. fee must be at 6300 Southcenter Blvd.. uite 100. Call o schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ta. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Oc( —a6( Project: 1 Type Inspection: t Address: i40(( MAC kM Date Called: Special Instructions: v Date Wanted: —Z3 - a•m• Requester: ' Phone N_of,- �j �j (001S- JApproved per applicable codes. Corrections required prior to approval. COMMENTS: !) Ki ceA ( -,> `T- , _SA (We A rh :--- t L14J r& i f-it^ J ST /...lo-r- ae.._. ---bri (3) C : Lam. 0 (. r (c_I ) a /`` v � n . REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspf ctor: !Date: INSPECTION RECORD Retain a copy with permit INSPEC ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 11�° Project: Type of Ins ection: Address: 140 l ( AM-6-4-6A iii Date Called; emir, ..,,,F#0..3- - - Special Instructions: .• Date Wanted: w --3 - i i to i a.� „,:..' p.m. Requester: Phone No// q�++�y e�'. %its ie � � 1'"�'O ”" 0 ° 41--C Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspg(tor: 04 Date: s ! REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �.. :.•p• { -• ;•ter-.. • INSPECTION. RECORD Retain a copy with permit INSPECTION'NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION NC 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �tg Project; fn' r / v key of Inspect' gn, { Addre s: 15, 0 I k lit A C-A,0 Y4- A-r Date Called: Special Instructions: O S 0 J I 1— a i s Date Wanted: Le S , a^R:RC Requester: Phone Nc6 .4decse' )4$ Approved per applicable codes. DCorrections required prior to approval. fi COMMENTS: e Ins pect : Date: j 3� t ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. TWA, v 9nYr`E-..- a,,a -a,p 1.1'7x; :-7. y • :m; v • . - , .. _ ..: INSPECTION RECORD Retain a copy with permit INSPECT ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project: `,� { W Type o se ct�o�n:`s 4 Address: 1-40/1 MACADAM Date Called: Special Instructions: f• Date Wanted: j ..„ a.n,', Co t — !' ii p.m. j Requester: Phone 9 lam' E( (a°4 Approved per applicable codes. COMMENTS: Corrections required prior to approval. (4re •(� j' 2) S`„ ()�j �� _s-' 2 /5 st el • In pector: Date:.' .v/ I REINSPECTI ON FEE EQ UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • ., ti . Y • L. ..—:7r yY ....'. .. -55(.-+"Tpv -:•;r i:77 �"r.G'^.A "rrcx.s"Y.c. i ! •'i • ... . RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,o_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ProJt 1 t ...c • Type s i b 6, Address: Date Called: Special Instructions: i Date Wanted: 40 — 1 r l{f ,/m p.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. /,• COMMENTS: Ins ector: Date: `Li o 1. C.) T7 REINSPECTION FEE REQUI ED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. . rf M1. .:7""ACTNar: r ;:E v:a'.gilC'A rr..- : �! r yx y-.r - . « -•r=' " 77.9.y. "e "7-_ `t'; - • - - K - INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,1.)// -ate PERMIT NO. ,/ A CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 • Permit Inspection Request Line (206) 431 -2451 Project: C AST/Liz AgS Type of Inspection: / aen1oVV srdPto4k 4 Address: /4/40// r774(1'4 6417746 Date Called: /� Special Instructions: / Date Wanted: 7- .2o-// p.m. Requester: Phone No: Approved per applicable codes. • r � Corrections required priorto approval. . • • • COMMENTS: nsp ctor: 1 Dater f LLA \) f n REINSPECTION FEE REQUIRED. Dior to next inspection. fee must•be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. R -15 Insulation within 2x4 cavity CROSS SECTION ELEVATION SIDE- LEFT VIEW R -15 Insulation within 2x4 cavity CROSS SECTION ELEVATION FRONT VIEW 2nd floor exterior envelope will remain intact except for Bathroom Wall Bathroom Wall will be insulated with R -15 within 2x4 cavity LIVING ROOM BEDROOM Insulation for the exterior building envelope will be rated R -15 within 2x4 framing (per section 101.3.2.5 of the WSEC) Flooring will not be insulated (at this time) under exception WSEC section 101.3.2.5 Any walls on the outside envelope that is firred to 6 inches will be insulated with R -21 Insulation Unable to determine U factor of existing windows;Any new windows will be compliant to WSEC DIAGRAM NOT TO SCALE REVISES No changes shall he made to the -nn of work wit cui prior appravai Tukwila Building Division. NOTE Revisions will require a new plan sul, -- and may include additional plan review f :: ]. SEPARATE PERMIT REQUIRED FOR: ViMechanic al tit Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION Fr_ R -15 Insulation within 2x4 cavity SHEET #1 4 / REVIEWED FOR ODE COMPLIANCE APPROVE APR 18 2011 /l - Cityof a ila BUILDING . VISION FILE Cory Permit No.. TA `'701-( Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ondlnance. Receipt of approved Reld Copy and c is ceded: CORRECTION City Of BUILDING DIVISION RECEIVED MAR 31 2011 PERMIT CENTER 2nd floor exterior envelope will remain intact except for Bathroom Wall Bathroom Wall will be insulated with R -15 within 2x4 cavity .. i LAUNDRY BEDROOM LIVING ROOM R -15 Insulation within 2x4 cavity CROSS SECTION ELEVATION FRONT VIEW 2nd floor exterior envelope will remain intact except for Bathroom Wall Bathroom Wall will be insulated with R -15 within 2x4 cavity LIVING ROOM BEDROOM Insulation for the exterior building envelope will be rated R -15 within 2x4 framing (per section 101.3.2.5 of the WSEC) Flooring will not be insulated (at this time) under exception WSEC section 101.3.2.5 Any walls on the outside envelope that is firred to 6 inches will be insulated with R -21 Insulation Unable to determine U factor of existing windows;Any new windows will be compliant to WSEC DIAGRAM NOT TO SCALE REVISES No changes shall he made to the -nn of work wit cui prior appravai Tukwila Building Division. NOTE Revisions will require a new plan sul, -- and may include additional plan review f :: ]. SEPARATE PERMIT REQUIRED FOR: ViMechanic al tit Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION Fr_ R -15 Insulation within 2x4 cavity SHEET #1 4 / REVIEWED FOR ODE COMPLIANCE APPROVE APR 18 2011 /l - Cityof a ila BUILDING . VISION FILE Cory Permit No.. TA `'701-( Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ondlnance. Receipt of approved Reld Copy and c is ceded: CORRECTION City Of BUILDING DIVISION RECEIVED MAR 31 2011 PERMIT CENTER This window will be removed FIRST FLOOR LAUNDRY H2O TER ROOM 1 This section of wall will be closed 1 LIVING ROOM If necessary, this wall may be firred out * ** This interior non -load bearing wall will be 11 removed t DINING 'll I I 11 11 Pantry room door will be replaced by a bi-fold door PANTRY Direction of stairs 4--. ST R' CASTILLO PROJECT ADDRESS: 14011 Macadam Road, Tukwila, WA 98168 Project Contact: Jun Castillo 206 - 948 -6045 Drawing not to scale u r1 1 KITCHEN WEST This will be a new window(approx 3x2) 1 This window will be e".. ' removed n REF This wall will be re- framed++ New 0 BATHROOM 1 waf This is a new non- load bearing wall ROOM 2 This is a new room 'n If necessary, this wall may be Jarred out �- -- This window will be replaced by a smaller window(2x2) This ceiling will be lowered 8 f t from floor This window will be removed EAST SECOND FLOOR SHEET #2 fit. I— REVIEWED FOR !CODE COMPLIANCE - APPROVED APR 18 2J11 ri l . f Tukwila BUILD! DIVISION' THIS FLOOR SECTION TO BE REPLACED WITH 3/4 OSB T &G 0 ROOM 3 THIS FLOOR SECTION TO BE REPLACED WITH 3/4 OSB T &G OPEN ROOM This wall will be re- framed++ • BATHROON CZ If necessary, this wall may be firred out * ** This ceiling will be lowered 8 f t from floor Direction of stairs I-0 S A S THIS FLOOR SECTION TO BE REPLACED WITH 3/4 OSB T &G ROOM 4 R-15 Insulation (2x4 framing) THIS FLOOR SECTION TO BE REPLACED WITH 3/4 OSB T &G RECEIVED MAR 31 2011 PERN11TCENTER 32 LE FT FLOOR PLAN : TOP VIEW between 1st and 2nd floor BALLOON FRAMING \ BACK LAUNDRY BEDROOM 2FT KITCHEN BATHROOM 2 FT LIVING ROOM BEDROOM BALLOON FRAMING FRONT 34 FT 2FT 8 FT RIGHT 12 FT CROSS SECTION VIEW LEFT SIDE 8FT —* 12 FT 32 FT 12 FT Vertical lines indicate the joists for the second flooring These are the original load bearing walls of the home Horizontal lines indicate the load bearing walls No load bearing walls will be removed DIAGRAM NOT TO SCALE 2s4 balloon frLming CROSS SECTION VIEW RIGHT SIDE 2 a 6 joists LAUNDRY load bearing wall (2x4) BEDROOM Load bearing wall (2x4) LIVING ROOM IMMNINIMMINIMMIMMIONIMMINIIEMMMINIMUMIll I 1 1 1 1 1 8FT —* 12 FT 32 FT 12 FT Vertical lines indicate the joists for the second flooring These are the original load bearing walls of the home Horizontal lines indicate the load bearing walls No load bearing walls will be removed DIAGRAM NOT TO SCALE 2s4 balloon frLming CROSS SECTION VIEW RIGHT SIDE 2x8 joists 4x2 Beams Concrete Perimeter Pier and posts 12 FT 12 FT 32 FT 12 FT SHEET #3 fife REVIEWED FOR CODE COMPLIANCE • APPROVED APR 18 201 City of Tukwila BUILDING DlvIsinmi RECEIVED MAR 31 2011 PERMIT CENTER 411 rkM1 411 I Load Bearin B L. \\ 12 FT E -8FT FIRST FLOOR FOUNDATION VIEW 12 FT POST BEAM 6x8 JOISTS (20 in @cent. 2x8 2 x 6 joists 4 load bearing wall Rag) BEDROOM BATHROOM % load bearing wall f )2x4) KITCHEN 2x8 joists 4x2 Beams Concrete Perimeter Pier and posts 12 FT 12 FT 32 FT 12 FT SHEET #3 fife REVIEWED FOR CODE COMPLIANCE • APPROVED APR 18 201 City of Tukwila BUILDING DlvIsinmi RECEIVED MAR 31 2011 PERMIT CENTER 411 rkM1 411 I Load Bearin B L. \\ 12 FT E -8FT FIRST FLOOR FOUNDATION VIEW 12 FT POST BEAM 6x8 JOISTS (20 in @cent. 2x8 L61481E-0 Gt IL In G $ taipivy F4.1,1 I REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2u11 City of Tukwila BUILDING DIVISION! RECEIVEr MAR 31 2011 PERMIT CENTEF SHEET #44 NAILING SCHEDULE t. angel, tr0rig arJvs are strap wnecton d r.4 be gddeied a rat nature patted. *Es cr tots to• 47744:444 sfdl be os spacrbo v ported a! r vkater 2 Ni etapr rib that be admiral Pyuoa side be wied adh 401,1%7 edb. AP posts cortobso r the sad mitt that txce m a 2. s2i plat to ere !emoted Mt/ 4-8d nett, Wass rood adaenebe. FreostmOtg pose shat be O toot h a woad sawe No rota post / column hoes or per degb. C baTORS Alit.* a) .bat to stn a gteer, t,",ai 364 0 ePist, towel J 24d d P.b's #loon a c as to hjoist, tote at 2 -td 4) Etch toe 1'4' seta to e0tiajoist, tae nil I 34d 61 7 bdger to sad A7; r rar roe Ybd ea sad . 6d 0 IT oh.'to:Nero: 11 Sob Otte to -'06t r ttsaa j to s yl I 160 a tb' Oc. gl Top plat to sae, ere la 2-Ied hl Stall to sot oiae 444 toer& n- 2-lbd, ma roc! U Pads somas 'me 'a 16d 0 24' or.. ! Data tz saas.'e.:e bd 0 b' at. t) Top pays, cos ae imseatcre, taco rna 24bd V eOthats 'tab re aeces 160 0 lb' a. tang ea edge al CMtg pnm a axe two 50d d Gathers %saw :: ac :sera 4-0d o) Gering pits ere : 1,t- 7osun !ze spa g..itd p1 awns1o'at xzse :: -Sirs ri i-Ibd o) Rater a tam Lass Rater to - ■ ` ac'x 38d 6d karats a 6' ot. etch skis r) t' nary to ear s:a x are rocs sr led A frte yNa1'e r o: _ as • =ix) tze » 2-0d tJ Alb- day 'e' sossr _ oar owes kce rat 3.0d d 911t,Q cow spa ltd 024' oz. VJ t12.06 e 20d09Ya.atopcd bates and staggered 2- 2WOddrad0oath rd Y playa 'u araey 240d 0 ea beahg 4 Rfaod ue arxe x1,: -, Sett, rod re as aerr. t...s •avgt. &e' ac err ear tw-- - u Deer bas . - ' Gds I-:!' - tin IGif a t e Goeiaa Sever +oruree `o horiryt a"' x est bas a 1i0-7 was e lee or R s gl Par. Sing'_`arc- .:aee rds St' 6di d Recant Sara. -• No. 6 tp.o Gds Ns. tb ga., 53..- R0.1 921 - ge db.16 di' :4# r ]C1, 11' >n A Ara eeopt were cast-Nibs stied 2 Urea. 7 aslasee so: r :0470. • .'Osage eat s 406 rases 6' a .em's edges, 0' at itaeodrte s aporb hi at isetedsy scam y w, • Carew -asset sot T sag rad. s Fastest,' arse 2' 7 :ate s reatrbr edges-t t 6' d 0R supports **of spas we a ryes x are `710x'9 d p good ad claptrap cc rex was -ercr 'arcs %Ceara. Hob fa drag be carat as or casrg s Gorosb--eeetrt -arm - x6.0:-'16' &seder Ivai 0d I-VY asp ka U2' deahrg and -Sa' ie r t1, 537 shecarg, ' 4 Carrosbr wart sues 4" load V6' crown ad Kr bngth for lit drawng x :7 sac kr 537 stadtag remove window FIRST FLOOR UTIUTY 0 ROOM 1 \ a LAUNDRY m H2O HEATER Y -r. 6- dose DINING Crjr\-A1.6 z(A2—qt.kgr_c0141---- New 2x3 window OPEN PANT x ti. , PANTRY STAIRS REF BATHROOM 1 Re front wail only CASTILLO PROJECT ADDRESS: 14011 Macadam Road, Tukwila, WA 98168 Project Contact: Jun Castillo 206 - 948 -6045 co 0 G) �' ®,i cc. ;. rn No CD —Po g2 z CD) remove 5 x5 window Remove window Add smaller window above shower • 1 bt Olob move bay window a)' I & Ib (Anil lvac( yeattic, RECEIVED MAR 14 2011 PERMITCENTER SECOND FLOOR 4'-0'x6 =8'SD 4'-0'x6' -8'SO Floors removed and replaced with 3/4 OSB sheathing Floors removed and replaced with 3/4 LOFT OSB sheathing 7-6 x 6'-8" Add railing re-drywall bathroom BATHROON 2 Floors removed an OSB sheathing STAIRS Floors removed and replaced with 3/4 OSB sheathing ROOM 4 W L 0 0 pip 8 Ni 0 Frii✓ op 0 m mOi03 ilea) wahI v2X4 -1� {t VWrl (,o 9 4 placed with 3/4 ECEIVED MAR 141011 ,� PERMIT CENTER N 2)(c A (CAS CAW IfIL LIJ cue LIJ REVIEWED P CODE COMPLIANCE APPROVE APR 182uil City of Tukwila BUILDING DIVISION IA) BALLOON FRAMING 4 Ldkv 1^— X16 L ta��l N- c T 'f ( tee BALLOON FRAMING 2 x 6 joists are actually 15/8 x 6 inches and NOT 1% x 6 Joists are supported by interior walls every 12 feet. FOUNDATION IS POST AND PIER 1�0 (4)/0° 5 -p v16 w(u- Be ED 4ar'S RECEIVED MAR 14 2011 IA PERAfiITCENTER EXISTING FRAMING COI 1INUOU& WOf ib STUOmS FLOOR SHEATHING —, 2X FLOOR JOISTS FACE NAIL JOISTS TO STUD LEDGER, RIBBON OR REMAND BALLOON 05c,,E FRAMING IN) Om 0 co O m m 0 m RECEIVED MAR 14 2011 PERMIT CENTER -.3' 14011 Macadam, Tukwila, WA SCOPE of REMODEL GENERAL • Remove all lathe and plaster on first floor (ceiling and walls) and replace with sheetrock • Install Insulation to all exterior walls • Install plywood /OSB to first floor as underlayment #or - laminate .iooring if necessary • Drop down ceiling to 8 ft in some areas on first floor. KITCHEN/DINING AREA • Remove 5 x 5 foot kitchen window and frame(north wall) ; install small window (3x2 /XX) on east wall • Remove interior wall between dining and kitchen • Open Pantry for bi -fold door LAUNDRY ROOM • Frame and close wall between laundry room and Room 1 FIRST FLOOR ROOM 2 • Frame and Build walls North east corner of home forbedroom • Frame window and build wall to exterior of northeast bedroom FIRST FLOOR BATHROOM • Frame front entrance wall of first floor bathroom • Close window in first floor bathroom and possibly install small 12 inch window above shower. • Shim first floor bathroom walls to add width for plumbing UTILITY ROOM • Remove window, frame and block SECOND FLOOR BATHROOM • Remove existing drywall; replace drywall • Shim studs to increase width for plumbing • Floors removed and replaced with % OSB Sheathing SECOND FLOOR ROOM 3 • Floors removed and replaced with % OSB Sheathing SECOND FLOOR ROOM 4 • Floors removed and replaced with % OSB Sheathing SECOND FLOOR LOFT • Add railing around stairs • Floors removed and replaced with % OSB Sheathing zo 7 ar 0 /8 0= <5;r13, 0 m RECEIVED MAR 14 2011 PERMIT CENTER g4 N31N3011Med — ilOZ I VW 3A1332 ,,. • 1'1 ,71 I '4EZA 1,44 ''' •", 'At., '•I'Pt.' ".■,,, • ...,ikdeS 46vt, ' tu■Pszi,l, ;4, v, 41Y- '':0.1.4V-Zgg. • • 120044074,1.1474 v---aagqk2zcrtr*QozzooFrogtstvxKig6.,,,-: • •J KJ . * . . - ':-.1...-1—,,,,,=1,-.rArt.........,,A.,....4........."— . t i .., • . . ■ ,..*;,.....,'I 4.-neg'41.''0,,.0-.11---- _. . 1 ,,,: "41w 44 V., .4:Aitifk -, -. ),;,,-.14 tIL•rottiiiiZAZ:P7 * ' \ ff .1.:..11,4;i: ^ ••■%,-:1 = ODD ® x.� C) -.0. }--y rri rn- -AP OM Z i CD m REGEEVErt MAR 14 2011 PERMIT CENTER r • • Summary of Revisions: #1 Open walls include the entire first floor exterior building envelope and the 2 "d floor Bathroom wall ONLY All open walls of the exterior building envelope will be insulated with R -15 insulation within 2x4 framed cavities /walls. If any walls of the exterior envelope are firred to 6 inch thickness, that wall will be insulated with R -21 insulation. #2 Unable to determine U -value of existing windows. All new windows installed will be compliant to the WSEC #3 Sheet #2; this sheet indicates which wall will be removed and indicates new walls as well. #4 Sheet #3; This sheet explains where the Toad bearing walls are located. They are supported by the original subfloor; joists, and beam. #5 Sheet #3; this sheet provides dimension of perimeter of the building and specifies the span between load bearing framing. #6 Sheet #2; The laundry room, the kitchen; and the two bathrooms may be firred out to 6 inches to accommodate for plumbing or venting. The pantry door may be altered to accommodate for a bi -fold door. #7 Sheet #2; Shows stairs and direction of stairs. #8 I am unsure why a site plan is needed to identify the characteristics of the roof line. No exterior work will be done. There is no site plan #9 Sheet #2; shows new and removed walls #10 Sheet #2; Sheet #4 The following rooms will have the ceilings lowered to accommodate for exhaust venting: First floor bathroom, 2 "d floor bathroom, Laundry Room All other rooms on the first floor may be lowered if necessary for ducting #11 All Sheets #12 Plywood subfloor for 2nd floor % OSB T & G and other sheathing use 8d common or 2 " screws. Nails spaced at 6" on center at edges, 12" at intermediate supports. Other miscellaneous nailing schedule see Sheet #4. #13 New mechanical systems and ducting shall meet the requirements of the 2009 WSEC. New ducting shall be installed and inspected per the mechanical code and WSEC. Duct testing will required. CORRECTION bftO&b ECEIVED MAR 312011 PPRM1TCENTER March 25, 2011 • Gity of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jun Castillo 13355 56 Ave S Tukwila, WA 98178 RE: Correction Letter #1 Development Permit Application Number D11 -066 Castillo Residence —14011 Macadam Rd S Dear Mr. Castillo, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fer Marshall t Technician enc File No. DI 1 -066 W:\Permit Center\Correction Letters \2011\D11 -066 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 i Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: March 17, 2011 Project Name: Castillo Residence Permit #: D11 -066 and M11 -035 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The project shows all walls exposed from the inside. As a result the insulation value shall be identified or specified on the plans for floors, walls and ceilings. Since this is an existing building some exceptions are allowed per the 2009 Washington State Energy Code section 101, 101.3.2.4 (WSEC). Provide an elevation cross section of the building construction that specifies all existing or new construction. Identify each type and size of framing members and specify the insulation for the exterior building envelope. Also refer to Table 6 -1 of the WSEC. Energy codes are available on line at the bottom of the page in the link below. (https://fortress.wa.gov/ga/apps/sbcc/Page.aspx?n id =14) 2. Please specify type of all windows with the "U" value of the windows. Identify on the floor plan any windows existing not to be replaced as well as new proposed windows. 3. Plans provided are a little confusing where some walls are highlighted with a note specifying new wall and on the plan view indicating the walls to be removed. Please provide clarification to explain which rooms exist or if the rooms have been modified in size with the new walls indicated. Show walls removed and show new walls added. 4. Sheet 4 please explain which level we are looking at or which floor this is indicating. Also since there are bearing walls, as shown, specify where they are bearing down to a foundation or post footing. This may also be specified in the elevation cross section for better clarification. The bearing walls indicated need to line up with the other plan walls on other plan sheets for consistency. Please note: regardless of the size of existing materials the size is always identified as 2x4 or 2x6 for simplification of material call out. 5. Provide dimension of the building perimeter and specify with dimensions spans between load - bearing framing; to verify if material spans are sufficient for the imposing loads. 6. Please specify which walls are altered or fir out of walls. 7. Show the stairs and direction of the stairs on both floors • • 8. Provide a site plan that identifies the characteristics of the roof line. Site plan can be part of the cover sheet with other code information of project documentation. 9. Some of the scope of work indicated (Scope of Remodel sheet) is not consistent with the floor plan shown and walls indicate new or removed. Provide notes on the specific plan pages to indicate the scope of work on that plan sheet for that floor level. Number all sheets. 10. Scope of Remodel notes indicate the lowering of a ceiling in various rooms. Provide specific details to show how the ceilings are to be built. Indicate on the plan where those ceilings are to be lowered. Show the final ceiling heights. 11. Clearly identify all new work with details and specifications. 12. On all details and methods of framing or sheathing, specify fasteners. Hardware and spacing of all fasteners in sheathing. All methods of construction and energy compliance shall comply with the 2009 International Residential Code, Mechanical code, Uniform plumbing code and WSEC. This information shall be specified on the plan cover sheet. 13. New mechanical systems and ducting shall meet the requirements of the 2009 WSEC. New ducting shall be installed and inspected per the mechanical code and WSEC. Duct testing shall be required. Include notes on cover sheet. (2009 WSEC 101.2.3.6 and Section 503) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • 14011 Macadam, Tukwila, WA SCOPE of REMODEL GENERAL • Remove all lathe and plaster on first floor (ceiling and walls) and replace with sheetrock • Install Insulation to all exterior walls • Install plywood /OSB to first floor as underlayment Jor -laminateflooring if necessary • Drop down ceiling to 8 ft in some areas on first floor. KITCHEN/DINING AREA • Remove 5 x 5 foot kitchen window and frame(north wall) ; install small window (3x2 /XX) on east wall • Remove interior wall between dining and kitchen • Open Pantry for bi -fold door LAUNDRY ROOM • Frame and close wall between laundry room and Room 1 FIRST FLOOR ROOM 2 • Frame and Build walls North east corner of home for bedroom • Frame window and build wall to exterior of northeast bedroom FIRST FLOOR BATHROOM • Frame front entrance wall of first floor bathroom • Close window in first floor bathroom and possibly install small 12 inch window above shower. • Shim first floor bathroom walls to add width for plumbing UTILITY ROOM • Remove window, frame and block SECOND FLOOR BATHROOM • Remove existing drywall; replace drywall • Shim studs to increase width for plumbing • Floors removed and replaced with % OSB Sheathing SECOND FLOOR ROOM 3 • Floors removed and replaced with % OSB Sheathing SECOND FLOOR ROOM 4 • Floors removed and replaced with % OSB Sheathing SECOND FLOOR LOFT • Add railing around stairs • Floors removed and replaced with % OSB Sheathing RECEIVED MAR 14 2011 PERMIT CENTER T Copy PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -066 PROJECT NAME: CASTILLO RESIDENCE SITE ADDRESS: 14011 MACADAM RD S Original Plan Submittal X Response to Correction Letter # 1 DATE: 03 -31 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT : BGilding !vision t Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04-05-11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route l Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05-03-11 Approved n Approved with Conditions V Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -066 PROJECT NAME: CASTILLO RESIDENCE SITE ADDRESS: 14011 MACADAM RD S X Original Plan Submittal Response to Correction Letter # DATE: 03 -14 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTME 45: .eding iN Iision Public or s TS: MA Af Fire Prevention Planning Division Structural Permit Coordinator 31 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03-15 -11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 04-12-11 Approved n Approved with Conditions Not Approved (attach comments) N Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg .e ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 41 1 Plan Check/Permit Number: D11-066 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Castillo Residence Project Address: 14011 Macadam Rd S Contact Person: Juh cao loo Phone Number: 206 -q -40`45- Summary of Revision: 3e6 Ai* ttA RECEIVED ,MAR PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revis Received at the City of Tukwila Permit Center by: �}— Entered in Permits Plus on \applications \forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplan@ci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433-0179 Planning Division 206 431 -367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: 1 0 (p 4 STATE OF WASHINGTON) ) ss. COUNTY OF KING ) [please print name] , states as follows: EL.11 - 00_01 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.09• of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number I Z , and will therefore not be performed by a registered contractor. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Signed and sworn to before me this / day of 4pr ) ,20j. (}/''("( NOTARY PUBLIC in and for the State of Washington Residing at VI Oj Name as commissioned: My commission expires: , County / 059 -(y 18.27.090 Exemptions. The regiition provisions of this chapter do not apply 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor, 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions.