HomeMy WebLinkAboutPermit D11-070 - LIEBERT CORPORATION - SEISMIC CONNECTIONSLIEBERT CORPORATION 3415 S 116 ST Di 1-070 City oPfukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049043 Address: 3415 S 116 ST TURIN Suite No: Project Name: LIEBERT CORPORATION DEVELOPMENT PERMIT Permit Number: D11-070 Issue Date: 05/09/2011 Permit Expires On: 11/05/2011 Owner: Name: RREEF AMERICAN REIT II Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: PAUL WLASCHIN Address: 2125 1 AV #804 , SEATTLE WA 98121 Contractor: Name: MARK PATTERSON CONST LLC Address: 310 221 ST SE , BOTHELL WA 98021 Contractor License No: MARKPPC957M2 Phone: 206 730 -5358 Phone: 425 - 481 -4887 Expiration Date: 07/22/2011 DESCRIPTION OF WORK: INSTALL SEISMIC CONNECTIONS TO EXISTING STORAGE RACKS IN WAREHOUSE Value of Construction: $0.00 Fees Collected: $243.92 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIIB Occupancy per IBC: 0008 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11-070 Printed: 05 -09 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied hether specified herein or not. N Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances The granting of this permit does not pre construction or the • : • • rmance o . ork. I to this pe rmit tt Signature: Print Name: ve authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this development permit and agree to the conditions attached Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in doc: IBC -7/10 D11 -070 Printed: 05 -09 -2011 the permit, the structural observer shall subalp the Building Official a written statement th a site visits have been made and identify any reported defici s which, to the best of the structural observlaiowledge, have not been resolved. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11-070 Printed: 05 -09 -2011 • CITY OF TUKWILA Commrmity Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 1 Building Permit No. 1 0 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. YVvIA (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** LSITE LOCATION King Co Assessor's Tax No.: /0 b ¢ 4 0 4--i 34-i.' 5. �� iB SiQ c.� Suite Number. 105 -Fleet" .646 5. Site Address: ,�,.�/ Tenant Name: Lt01 ;e P fr70N New Tenant: Yes ❑..No Property Owners N : f .64.- g 'A' 6 ,T A14411IM 7 *iiKifido.6roki �O l b� Mailing Address: t) lL Sg1L / ,g.�ZD� �;y - /ut- 12.1 no �� std. ZiP ICONTACT PERSON — who do we contact when your permit is ready to be issued AA,��� &IL Ili t^) Day Telephone: LY�iO ' 75 D - ,_� Name: Z12SGd �� !Q'(/(� o _A -�i� GU1�' J�'r1.9 -/ Mailing Address: Cty N smae Zip Fax Number. do r-2446 E -Mail Address: i /46 O , GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing /iand Gas Piping (pg 5)) t Company Name: maim P4- €bate D i. S12 l/ a Mailing Address: t 0 4 VS4e City Day Telephone: Fax Number. Expiration Date: Contact Person: 11AJLVkJ Pak Gebtactsi'. f t r E-Mail Address: Contractor Registration Number. /v1A'4l; f iL 4,51 II/12 MAK IC ,�a.�it.) l ARCM 'MCI* OF RECORD — All plans must be stamped by Architect of Record Company Name: 424' &144 a- Mailing Address: Contact Person: E-Mail Address: kV A-- 9 'D / �oi07 y /S'- 3!'Z 1s J2 Pi4 cr %Z /Zbi g(2.0 Eu a2m Live. J I. _(aidcoL* Day Telephone: -- l 2O ICt.47 '.- Q l� • P AA Fax Number ENGINEER OF RECORD — All plans must tis •O tamped by Engineer of Record Company Name: ' ff 1 cG'. ��to.4 . Mailing Address: GEC' �� ®II5�,`, �I 13' Contact Person: A A',f aff -Iftt_ — City D�ty Tel = , hone: AJA- State Zip Iola- loci7- alp • BUILDING PERMIT INFORMIATION -286- 43314670 Valuation of Project (contractor's bid price): S D Frilling Braiding Valuation: $ Scope of Work (please provide detailed information): i# l °3!A'LL 1:11.4 it t_t t ' eat fG 5/6 Mkt, f iltIC — /n1 (e) - 'LAMA. mice. Will there be new rack storage? W. ---Ycs 1" Floor. 2" Floor 0- No fyes, a separate putt and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel 'roll). ztre6.5e 3f4 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Addition in Fig Structure Al . New Type of Coon per IBC Type of Occupancy per MC OPreat- itshehfil PLANNING DIVISION: than 18 'Indies) Single family building footprint (area of the foundation of all phis any decks over 18 inches and o greater *For an Accessory dwelling, provide the following: Floor area of principal dwelling Floor area of accessory dwelling Lot Area (sq lives in One of the dwellings as bis or her prim' ary residence. *Provide documentation that shows that the pi>ncipal owner Compact Aandicap._ Number of Parking Stalls Provf� Standard: Will there be a change in use? 0—.Yes ®. No If "Yes • explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Other (specify pr�� 1j,.— Automatic Fire Alarm 0 .__.None ❑ or use of llasmnablc, comb�ible or hem materials in the building? 0—Yes Will there be storage !madams an asep� 8-12 "s 1I" paper i dwFo g quantities and Material Saf Sheets. /J'� : attach Gar ojnmteriats meet SEPTIC SYSTEM ❑_pn.site Septic System —For one septic system, pmt 2 topics of =cat septic design approvcd by King County Health Department. 11141.*16 4nowaTr.wa4wi:...i...aft _ - ♦ - ss • • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN '�" O' • ENT: 11-.°11 worAio Signature: "" +- Print Name: L t(21-4-"3 2 ( Mailing Address: o2lo7s `16 74104.014 6'24' IDate Application Accepted: NI 11 Date: 3 MV/1 Day Telephone: 7006 - 7 '-53SB State Zip Staff Initials: Date Application Expires: Cris I I � 1 I ` } {IApplicationssFOnm- Applicatiuos Oa Iine12010 Applicatiaaal7 2010- Permit Applicationdoe Revised: 7-2010 Page 6 of 6 of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R11 -00926 Initials: JEM Payment Date: 05/09/2011 User ID: 1165 Total Payment: 857.95 Payee: PAUL WLASCHIN SET ID: 0509 SET NAME: LIEBERT TI SET TRANSACTIONS: Set Member Amount D11 -069 D11 -070 TOTAL: 708.35 149.60 708.35 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 857.95 TOTAL: 857.95 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 TOTAL: 848.95 9.00 857.95 Citfof Tukwila, 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R11 -00513 Initials: JEM Payment Date: 03/16/2011 User ID: 1165 Total Payment: 551.82 Payee: PAUL WLASCHIN SET ID: S000001484 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member D11 -069 D11 -070 TOTAL: Amount 457.50 94.32 457.50 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 551.82 TOTAL: 551.82 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 TOTAL: 551.82 551.82 ymlr . •,•T -'r :i%A. .1` 7 '471..1'7"... ! ®',�i y�` =� - -. ,♦ INSPECTION. RECO.RD,. Retain a copy with permit' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION rte" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • • Proj ct:• Type pection:. Address Date Ca i 8,j, to 1A Special Instructions: Date Wanted: t, ,(0 ..m. ` .-- \ p.m. Requester: P��° <S-3 Approved per applicable codes. aCorrections required prior to approval. COMMENTS: pig- t-r-&0 p erf Inspectgrr Date: Co REINSPECTION FEE REQUIRED. prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. ye -.yr...P.:es- --.77•41 • • 7.,":.r.r: MY... I. INSPECTION.RECORP Retain a cop)vith permit - 070 PERMIT NO. .••• ••::‘,10 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 r--- Project: ( 6`") 14 Type nspection: A-ALA Address: 3115 l (Co ' rk ,0". Date Called: Special Instructions: • ../r , Date Wanted ,.....22_11. p.m. Requester: Phone No: 61 —7_30 ---525S Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe tor: Date: (01 ( • 11 REINSPECTION FEE REQUIREDRrtto next inspection, fee must be • paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. Bruce S. MacVeigh, P.E. 14245 59th Ave. S. Tukwila, WA 98168 Office: (206) 242 -7665 Fax: Same Cell: (206) 571 -8794 June 8, 2011 City of Tukwila Attn: Building Official /Building Inspector D Subject: Special Inspections, Rack Shelving Floor Attachment for Existing Rack Shelves, Liebert Corporation Warehouse, 3415 S. 116th Street, Suite 103 /Bldg. 5, Tukwila, WA 98168 Dear Sir: This letter is to document the field inspection of several steps or components of the approved installation of floor to rack connection at the above location. Special Inspections - 1. Inspection of holes for anchor bolts drilled into the concrete. 2. Verification of correct size and rating of anchor bolts. 3. Correct placement and tightening of bolts into floor. Concurrently, verification of correct supplemental fabricated brackets (where used), and their proper connection to rack legs. The first inspection for Items 1 and 2 above was made on May 25, 2001. The holes were of proper diameter and depth, and had been air gunned to remove dust. The anchor bolts for all locations were correct and were type: Power Stud #7423FD1 Seismic Anchors, 1/2" dia. by 4 -1/2" length. The second inspection for Item 3 was made on June 2, 2011. All rack legs had been bolted to the floor. The Interlake racks used two bolts per leg and used the factory anchoring plates at the bottom of the legs. The Equipto rack was similarly fastened but used supplemental fabricated "L" plates fastened to the legs with two 1/2" bolts at each location into the leg. The Rivet Rack, Inc. racks had a single 1/2" anchor bolt at each leg, with a supplemental fabricated "L" plate fastened to each leg with two 1/2" bolts at each location into the leg. The fabricated "L" plates were made per the approved plans. Maximum loading signs were being prepared for each rack, and samples were observed and approved. The signs used the load ratings generated by this office and approved as part of this permit. Please note that while the loadings estimated for the anchors and the design of the anchoring of the racks to the flooring used conventional and conservative design considerations, it is always possible that an extreme seismic event% greater than used for the evaluation could still produce instability or damage to the shelving. Attached are several photographs showing the items observed during the above visits. Questions relating to the above may be directed to this office. Bruc- S. MacVeigh, P.E. Civil Engineer wlaschin05 /1110 E XPIRES: 4/24% 7 ,fv, ' j// Power Stud 1/2" x 4-1/2" Seismic Anchors Typical Interlake Rack Floor Connection Typical Equipto Rack Floor Connection Typical Rivet Rack Floor Connection Maximum Loading Signs for the Three Rack Types ..,FILE COPY Permit No. 'Ian review approval is subject to f'*;C`rf. 0f c:07- ' +!1ilaFChf 3;2011 Bruce S. MacVeigh, P.E. 14245 59th Ave. S. Tukwila, WA 98168 Office: (206) 242 -7665 Fax: Same ... Cell: (206) 571 -8794 i REVIEWED DE COMPLIPIK nolgOVED him' 0320 11 %otyofTU�e �• Subject: Rack Shelving Floor Attachment for Existing Rack Shelves, Lie f o of kwJIa Corporation Warehouse, 3415 S. 116th Street, Suite 103 /Bldg. 5, Tukwila, WA" a OI�/LgfQ 98168 Introduction. The warehouse portion of the above facility has a number of in -place storage racks used for the storage of both smaller items and larger mechanical components or boxed products. There are three identified makes of rack, each with its own characteristics and loading capacities. The requirement of this evaluation is to determine the appropriate connection of the racks to the warehouse flooring, which is slab -on -grade concrete, 2,500 psi, 5 inches thick. The loading which the connections are designed to resist is seismic loading using Toad levels equivalent to those in conventional low rise structure design. A safety factor of 1.5 will be used. A seismic transverse Toad factor of 0.2 will be used for this evaluation. Experience in designing residential and small commercial structures indicates this is a reasonable approximation and is of adequate accuracy for these calculations. Rivet Rack, Inc. Shelving. There are seven of these racks in a stand -alone configuration. Calculations are attached sizing the number and placement of anchor bolts to prevent overturning in the event of a seismic event. The dead weight of the shelves is ignored, however the recommended maximum shelf loading is assumed on each shelf. The height from the floor for the shelving calculations is as measured from the existing shelves. A vertical reconfiguration of the shelves is not foreseen. The shelves are relatively tall and narrow, 24" wide by 10 feet tall. Normally we,TRECErV would take into account the downward dead weight of the shelf loading as a resisting moment in assisting the resistance to overturning. In this case, it will be'' , 1 2011 ignored since a transverse shifting of the shelving center of gravity during an 3 tr. RRAiT CENTER DWO1D event could move the center of gravity enough to the side to remove its ability to stabilize the shelving. A design sketch and specifications for the floor connection are included in the calculations. Interlake Rack System. There are three of these units placed end -to -end, with common middle posts. One unit is 10 feet long (right unit), with the middle and left units being 9 foot long units. The heavy shelf loading of the 10 foot long unit (based on the number and height of shelves) is attached to the middle 9 foot long unit. This middle unit has the heaviest shelf loading of the 9 foot long units. This indicates that a design for the post connections to the floor for this set of common posts will be the worst case. Calculations are attached sizing the number and placement of anchor bolts to prevent overturning in the event of a seismic event. The dead weight of the shelves is ignored, however the recommended maximum shelf loading is assumed on each shelf. The height from the floor for the shelving calculations is as measured from the existing shelves. A vertical reconfiguration of the shelves is not foreseen. Since the width of these shelves is significant, being 4 feet, relative to their height, this being 8 feet, the dead weight of the shelf loading will be used to compute a portion of the resisting moment in determining the anchor bolt capacity of the post to floor connection: In these calculations, this factor is ignored, making these calculations very conservative. A design sketch and specifications for the floor connection are included in the calculations. Equipto Rack. There is one of these racks. It is in line but not connected to the Interlake racks. It is of very similar design and size of the 10 foot long Interlake rack with the exception that it is 3 feet wide. It has no common posts with other racks. Based on these considerations, the anchor bolt loading computed for the Interlake racks (with their double loading due to the common post use and wider 4 foot shelf loads), will be adequate for the Equipto rack by inspection, and Equipto specific calculations are not provided. Quest J'- lati to the above may be directed to this office. ruce S. MacVeigh, P.E. Civil Engineer wlaschin03 /1110 EXPIRES: 4/24/1/ 3/'7.®E %/ RIVET RACK, INC. SYSTEM UNITS Calculations 04.V! OM 9* ow I ms DI.- 9991 909 OK 1 9901 . 004 97,40 ttl9 titivi 0001 909 Otttol 9901 Ettati• . 7. A O't 0091 909 Orfile'l , 0001 - 9409 ..-. K INXIT 909 NM MI ixl, ,, •• sl :g z.-4 COG t 4S1. - etigt 7t .ttos ,.. • RV 00(11: Oflt •, „ tat 1 VA , ! VS: 0001 tlgt _ CNN 1 G. 0051-t 11001 tSt WS 1 WO I *Mit -.Otto I OW .9* -ne.1 9091 ..... OM OW I tgfa -9C. 05.41 MI 990?. VW I OSZ OZ V.Stt tiStt 3 , Mg.1 Mit •Mt trZ. •OSIT OR 1 9411 0061 KZ 91 Or •.' I OM • WW1 .1W !CU' z-t li ov Int n!. t1 9t H Bea I mesa z ji4 wads Dual Hi MINIS Own weds gaol witaguil 0 Jo J aged Wedge Anchors- Technical Information 'for Concrete Wedge Anchors and Fasteners YOUR ONE SOURCE FOR CONCRETE WEDGE ANCHORS ph: 888.498.5747 Ix: 888.498.4985 Purchase Wedge Anchors Wedge Anchor Technical Information Wedge Anchor Sizes, Packaging & Pricing Wedge Anchor Installation Instructions Wedge Anchor FAQ Wedge Anchor Common Names Concrete Wedge Anchor Articles VIEW OUR VIDEO TUTORIAL View Installation Video e All Orders Ship the Same Day Order is Received • Buy Direct and Save o Secure Shopping • Satisfaction Guaranteed OTHER CONCRETE ANCHORS Drop -in Anchors CONCRETE ANCHORS FOR BRICK & BLOCK Metal Hit Anchors Concrete Wedge Anchors Technical Information Concrete wedge anchors are available in zinc coated carbon steel, hot - dipped galvanized carbon steel, 303 Stainless Steel and 316 Stainless Steel. Holding Values Purchase Wedge Anchors Holding values shown below are ultimate holding values for the embedments shown. A safety factor of 4:1 (or 25%) is generally accepted as a safe working Toad. Anchor Embedmt. Torque 2000 PSI 4000 PSI 6000 PSI Diameter Depth Ft /Lb Tension . Shear Tension Shear Tension Shear (in.) (in.) (LB) (LB) (LB) (LB) (LB) . (LB) 1 -1/8 1170 1443 1771 1813 2773 2635 1/4 1 -3/4 5 -10 1841 1443 2408 1813 2773 2635 2 -3/4 1975 1443 2748 1813 2830 2635 1 -1/2 1631 4318 3636 5121 4448 6232 3/8 3 25 -30 3229 4318 5653 5121 5975 6232 (i 4318 6328 5121 6360 6232 7419 6714 9377 9616 9888 50-60 .. 7419 8942 9377 10192 9888 6 6902 7419 10175 9377 12064 9888 3 -3/4 4999 8264 8747 12928 9760 16373 5/8 5 75 -90 8854 8264 15590 12928 19802 16373 7 9381 8264 16710 12928 17732 16373 3 -1/4 6638 12504 11314 17050 16230 22965 3/4 6 150 -175 10084 12504 18408 17050 21092 22965 8 11170 12504 19805 17050 22522 22965 3 -3/8 8392 18250 16354 20234 16801 23980 7/8 5 -3/4 200 -250 12064 18250 18250 20234 23404 23980 8-2/3 12784 18250 16850 20234 25575 23980 4 -1/2 9773 23617 18250 27605 17460 28909 1 7 -1/2 250 -300 11890 23617 26726 27605 %'34960 28909 10 15590 23617 30491 27605 37840 28909 5 -1/2 17550 32275 22971 42690 32368 55566 1 -1/4 7 400 -450 21050 32275 27845 42690 48366 55566 . !!_. _...........1.... 4-......m ,.....1..... ,.r.....l..10r1 cr. .,nnl,r..r_tn1,l,n:r. 1 ncnv ragc1011 http: / /sz0013.ev.mail.comcast. net / service / home % / ?id= 37341 &part =2 &auth =co &disp =i 3/1/2011 rivet rack angle INTERLAKE RACK SYSTEM UNITS Calculations -t, Lt ; - .L_ I I 1 I , I , : A 1-- . IL H I I Ze..a ..t./ I . _1 : 1 I ---I - !:e __, ,C:>. /,..57714. •i' i i • . , ! ! • 1 ! i 1, 1 1 1 1 i ____L _ . .. . ..._•___ . • .. , 1 , , --- --i ---I--,--L- -L-•-- ---- ---42).2A1--Y - -69._ -2-. • 5-4"51--/1 -- . ,2'/ c- -• ,e-.; LL • L _ • "4"T"--• ..; • • 1- , I • • . H , ; .t. L-t-1.1-- k./.11541 I t '71 - - - - 773c, _ ---- - - —4 iLIL r:- I ! • !.. IC/194 - -H42 -44-4-57H4-41 ! I I I 71- I I,&.;• t- TLE — ; IT - • ;- lc • • Flxfure'/ Intei{ak' Beam Capacities (25E- 45E/110 "- 144 ") Note: Capacities are the same whether mounted to roll - formed columns or to structural columns. Maximum uniformly distributed load capacity (Ibs. per pair). C Ic eu 25E :: 2 -3/4' 30E_.:; 2^ . 32E 23(4' j 36 2 314' 4QE 45E -314' - 2 314' 12 1 1 ►t I 1' 1' S 1' • w ' Q* id s b c.1 0 s .. C t pi xe t 0 m 6 a r} 0: fJli 3,220 3,110 3,020 2,920 2,830 0.611 0.622 0.633 0.644 0.656 3,910 3,780 3,660 3,540 3 4 . • 0.611 0.622 0.633 0.644 0.656 5,080 4,910 4,750 4,600 4,450 0.611 0.622 0.633 0.644 0.656 110 112 114 116 1,320 1,280 1,240 1,200 1,170 0.611 0.622 0.633 0.644 0.656 1,610 1,550 1,510 1,460 1,410 0.611 0.622 0.633 0.644 0.656 2,530 2,450 2,380 2,300 2,240 0.611 0.622 0.633 0.644 0.656 ...1121 .� 122 124 126 128 1,130 1,100 1,070 1,040 1,010 0.667 0.678 0.689 0.700 0.711 1,370 1,330 1,290 1,260 1,220 0.667 0.678 0.689 0.700 0.711 2,170 2,110 2,050 1,990 1,940 0.667 0.678 0.689 0.700 0.711 2,750 2,670 2,590 2,520 2,450 0.667 0.678 0.689 0.700 0.711 &OP , 30 3,130 3,040 2,960 0.667 0.678 0.689 0.700 0.711 4,320 4,180 4,060 3,940 3,830 0.667 0.678 0.689 0.700 0.711 130 132 134 136 138 990 960 940 910 890 0.722 0.733 0.744 0.756 0.767 1,190 1,160 1,130 1,100 1,070 0.722 0.733 0.744 0.756 0.767 1,890 1,840 1,790 1,750 1,700 0.722 0.733 0.744 0.756 0.767 2,380 2,320 2,260 2,200 2,140 0.722 0.733 0.744 0.756 0.767 2,880 2,800 2,720 2,650 2,580 0.722 0.733 0.744 0.756 0.767 3,720 3,620 3,520 3,420 3,330 0.722 0.733 0.744 0.756 0.767 140 142 144 870 850 830 0.778 0.789 0.800 1,050 1,020 1,000 0.778 0.789 0.800 1,680 1,620 1,590 0.778 0.789 0.800 2,090 2,040 1,990 0.778 0.789 0.800 2,520 2,460 2,400 0.778 0.789 0.800 3,250 3,160 3,080 0.778 0.789 0.800 • Load capacitles are for uniformly distributed product load plus dead load per pair of beams (dead load m weight of beams). • Deflection In lhfs dual Is based on product load only and Is limited to 0180. • Beams longer that 90' that support decking must be tied together to prevent spreading. • Beams 60' long and under are designed for single pallet wide appticatlons. • Beams longer than 80' are designed tor 2 or 3 pallet wide applications. • Capacities have already been reduced for Impact loading. • Capacities are valid when beams are connected to Interlake frames. • Capadtles are based on the 2002 RMI and the 2001 AISI spedficatlons. • These capadtlee aasume that all component pane are: (1) manufactured by Interlake, (2) In good condition. (3) property installed Beam Capacities (25E - 45E / 36" - 108") Note: Capacities are the same whether mounted to roll - formed columns or to structural columns. Maximum uniformly distributed Toad capacity (Ibs. per pair). d v 25E : 2-3/4' 30E .::. r 32E 23/4' u, 36E ;• 23 /4' ,.40E., ,: i 2-314' 45E 2-3/4' 1' 1• 1 1' 1' 1• •.+rb%��� t t`; 1 'a'k..fa___ p a 1 W � a ■ ANSkK `•k r,c44. 1 3k"4" Ti D 11 °1 I'4 riA `.a3 J 36 38 40 42 44 5,750 5,460 5,200 4,960 4,750 . .. 0.106 0.118 0.131 0.144 0.158 6,670 6,340 6,030 5,750 5,500 0.099 0.110 0.122 0.134 0.147 8,620 8,200 7,810 7,460 7,140 0.084 0.094 0.104 0.114 0.125 10,210 9,690 9,230 8,810 8,430 _ 0.076 0.085 0.094 0.103 0.113 _ 11,650 11,060 10,530 10,050 9,610 _ 0.070 0.078 0.087 0.095 0.105 _ 13,930 13,210 12,570 11,990 11,460 0.063 0.070 0.078 0.086 0.094 46 48 50 52 54 4,550 4,370 4,210 4,060 3,910 0.172 0.187 0.203 0.220 0.237 5,280 5,070 4,870 4,690 4,530 0.161 0.175 0.190 0205 0.221 6,850 6,590 6,340 6,120 5,910 0.137 0.149 0.161 0.174 0.188 8,080 7,770 7,470 7,200 6,950 0.124 0.135 0.146 0.158 0.170 9,210 8,840 8,510 8,190 7,910 0.114 0.124 0.135 0.146 0.157 10,980 10,540 10,130 9,760 9,410 0.103 0.112 0.121 0.131 0.142 56 58 60 62 64 3,780 3,660 3,550 3,810 3,580 0.254 0.273 0.292 0.344 0.356 4,380 4,230 4,100 4,400 4,270 0238 0255 0.272 0.322 0.343 5,720 5,540 5,370 5,770 5,600 0.202 0.216 0231 0.274 0291 6,720 6,500 6,300 6,770 6,570 0.183 0.196 0.210 0.248 0.264 7,640 7,390 7,160 7,690 7,460 0.169 0.181 0.194 0.229 0244 9,090 8,790 8,510 9,130 8,860 0.152 0.163 0.175 0206 0220 66 68 70 72 74 3,380 3,200 3,030 2,870 2,730 0.367 0.378 0.389 0.400 0.411 4,150 3,940 3,730 3,540 3,360 0.365 0.378 0.389 0.400 0.411 5,450 5,300 5,170 5,040 4,920 0.309 0.328 0.348 0.367 0.388 6,390 6,210 6,050 5,890 5,750 0.280 0.297 0.315 0.333 0.351 7,250 7,050 6,860 6,680 6,510 0.259 0.275 0291 0.308 0.325 8,600 8,360 8,140 7,920 7,720 0234 0248 0.263 0.278 0293 76 78 80 82 84 2,590 2,470 2,360 2,250 2,150 0.422 0.433 0.444 0.456 0.467 3,190 3,040 2,900 2,770 2,640 0.422 0.433 0.444 0.456 0.467 4,800 4,690 4,510 4,310 4,120 0.409 0.430 0.444 0.456 0.467 5,610 5,480 5,350 5,230 5,120 0.370 0.390 0.410 0.430 0.451 6,350 6,200 6,060 5,920 5,790 0.343 0.361 0.379 0.398 0.417 7,530 7,340 7,170 7,010 6,850 0.309 0.325 0.342 0.359 0.377 86 88 90 92 94 2,060 1,980 1,900 1,820 1,750 0.478 0.489 0.500 0.511 0.522 2,530 2,420 2,320 2,230 2,140 0.478 0.489 0.500 0.511 0.522 3,950 3,790 3,630 3,490 3,360 0.478 0.489 0.500 0.511 0.522 5,010 4,850 4,660 4,470 4,300 0.473 0.489 0.500 0.511 0.522 5,670 5,550 5,430 5,330 5,220 0.437 0.458 0.478 0.499 0.521 6,700 6,560 6,420 6,290 6,160 0.395 0.413 0.432 0.451 0.471 96 98 100 102 104 pool . Ia 8 1,690 1,620 1,570 1,510 1,460 0.533 0.544 0.556 0.567 0.578 2,060 1,980 1,910 1,840 1,780 0.533 0.544 0.556 0.567 0.578 3,230 3,110 3,000 2,900 2,800 0.533 0.544 0.556 0.567 0.578 4,130 3,980 3,830 3,690 3,570 0.533 0.544 0.556 0.567 0.578 5,030 4,840 4,660 4,490 4,330 0.533 0.544 0.556 0.567 0.578 6,040 5,930 5,820 5,710 5,610 0.490 0.511 0.532 0.553 0.574 1,410 1,360 0.589 0.600 1,720 1,660 0.589 0.600 2,700 2,620 0.589 0.600 3,440 3,330 0.589 0.600 4 : ' 4,040 0.589 0.600 5,440 5,260 0.589 0.600 • Load capacities are for uniformly distributed product load plus dead load per pair of beams (dead load = weight of beams). • Deflection In this chart Is based on product load only and Is limited to L/180. • Beams longer that 90' that support decldng must be tied together to prevent spreading. • Beams 60' long and under are designed for single pallet wide applications. • Beams longer than 60' are designed for 2 or 3 pallet wide applications. • Capacities have already been reduced for Impact loading. • Capacities are valid when beams are connected to Interlake frames. • Capacities are based on the 2002 RMI and the 2001 AISI specifications. • These capacities assume that all component parts are: (1) manufactured by Interlake, (2) In good condition, (3) property Installed Wedge Anchors- Technical Informationfor Concrete Wedge Anchors and Fasteners YOUR ONE SOURCE FOR CONCRETE WEDGE ANCHORS ph: 888.498.5747 rx: 888.498.4985 Purchase Wedge Anchors Wedge Anchor Technical Information Wedge Anchor Sizes, Packaging & Pricing Wedge Anchor Installation Instructions Wedge Anchor FAQ Wedge Anchor Common Names Concrete Wedge Anchor Articles VIEW OUR VIDEO TUTORIAL View Installation Video • All Orders Ship the Same Day Order is Received • Buy Direct and Save • Secure Shopping • Satisfaction Guaranteed OTHER CONCRETE ANCHORS Drop -in Anchors CONCRETE ANCHORS FOR BRICK & BLOCK Metal Hit Anchors Concrete Wedge Anchors Technical Information Concrete wedge anchors are available in zinc coated carbon steel, hot - dipped galvanized carbon steel, 303 Stainless Steel and 316 Stainless Steel. Holding Values Purchase Wedge Anchors I Holding values shown below are ultimate holding values for the embedments shown. A safety factor of 4:1 (or 25 %) is generally accepted as a safe working load. Anchor Embedmt. Torque 2000 PSI 4000 PSI 6000 PSI Diameter Depth Ft /Lb Tension . Shear Tension Shear Tension Shear (in.) (in.) (L8) (LB) (LB) (L8) (1.8) (L8) 1 -1/8 1170 1443 1771 1813 2773 2635 1/4 1 -3/4 5 -10 1841 1443 2408 1813 2773 2635 2 -3/4 1975 1443 2748 1813 2830 2635 1 -1/2 1631 4318 3636 5121 4448 6232 3/8 3 25 -30 3229 4318 5653 5121 5975 6232 401liall 6 6902 4318 6328 5121 6360 6232 7419 6714 9377 9616 9888 7419 8942 9377 10192 9888 7419 10175 9377 12064 9888 3 -3/4 4999 8264 8747 12928 9760 16373 5/8 5 75 -90 8854 8264 15590 12928 19802 16373 7 9381 8264 16710 12928 17732 16373 3 -1/4 6638 12504 11314 17050 16230 22965 3/4 6 150 -175 10084 12504 18408 17050 21092 22965 8 11170 12504 19805 17050 22522 22965 3 -3/8 8392 18250 16354 20234 16801 23980 7/8 5 -3/4 200 -250 12064 18250 18250 20234 23404 23980 8 -2/3 12784 18250 16850 20234 25575 23980 4 -1/2 9773 23617 18250 27605 17460 28909 1 7 -1/2 250 -300 11890 23617 26726 27605 k4960 28909 10 15590 23617 30491 27605 37840 28909 5 -1/2 17550 32275 22971 42690 32368 55566 1 -1/4 7 400 -450 21050 32275 27845 42690 48366 55566 . ... .7 ._.. f . ...... ...... L. ..� ........ /..,oil ..n nr...I.r r_ta nl. r.:nnl ncn //v 70.4.47et_ EQUIPTO RACK UNIT Note: The Equipto unit is very similar in size and Toad configuration to the Interlake units. While its width is 3 feet compared to the Interlake units, its loading is also proportionately Tess. In addition, the Interlake calculations used loading from two adjacent racks at one common post hold down location whereas the Equipto unit, being a stand alone unit, has loading from only the one unit at each end. The Interlake calculations may be taken as acceptable hold down evaluation for the Equipto unit. This is very conservative. G taeJi/'7° 7a /75 3 i A" /40.7:41 b cro April 15, 2011 • City of Tukwila 41 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Paul Wlaschin 2125 1St Av #804 Seattle, WA 98121 RE: Correction Letter #1 Development Permit Application Number D11 -070 Liebert Corporation — 3415 S 116 St Dear Mr. Wlaschin, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, C Bill Rambo Permit Technician encl File No. DI1 -070 W:\Permit Center \Correction Letters \2011\D11 -070 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 Tukwila 'Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: April 14, 2011 Project Name: Liebert Corporation -Racks Permit #: D11 -070 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please add a section to the plans that specifically lists the allowed load limit for each shelf of the different rack types. Include a note that that states racks must be posted with appropriate load limit signs on minimum 5 x 10 placards. Load limits are currently shown in the calculations but need to be on the plans for contractor and inspection purposes. 2. Please add notes to the plan stating special inspection required or not for each type of anchor bolt to the concrete floor. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Y� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -070 PROJECT NAME: LIEBERT SITE ADDRESS: 3415 S 116 ST Original Plan Submittal X Response to Correction Letter # 1 DATE: 04 -20 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTME TS: -r/ Building ivision I Ii Public Works U Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04 -21 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-19-11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 r PERMIT 000flDCOM/ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -070 DATE: 03/16/11 PROJECT NAME: LIEBERT CORPORATION - 17,I9((VS SITE ADDRESS: 3415 S 116 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued D��EPARTMEN S: irding 'vision Public Works AW\ /A— 3 Fire Prevention I� Planning Division ❑ Structural U Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete XI Comments: Incomplete DUE DATE: 03/22/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/19/11 Approved U Approved with Conditions ❑ Not Approved (attach comments) KS Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: LV -M-1 t Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -2A -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4 6a(t( Plan Check/Permit Number: ❑ Response to Incomplete Letter # gResponse to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ( tP eAr f — cC-- 4114-1L- ijD�t� ,J S Project Address: C s- Cr/ r I cz Contact Person: ,� -c.t l„ 1iO[�•i°de�(,� � v\j Phone Number: -7---eC ^7 e Summary of Revision: Project Name: o 6-7t c r U n 947 `-6k__ L ��k?eeti fitIVEIVED CITY OF TUKWILA Sheet Number(s): C-- APR 2 0 2n11 "Cloud" or highlight all areas of revision including date of revi, Received at the City of Tukwila Permit Center by: ' tered in Permits Plus on H:\Applieanons\Forms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 PERMi7 CE►Ii �P Contractors or Tradespeople Peer Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MARK PATTERSON CONST LLC UBI No. 602485320 Phone 4254814887 Status Active Address 310 221St Street Se License No. MARKPPC957M2 Suite /Apt. License Type Construction Contractor City Bothell Effective Date 7/22/2005 State WA Expiration Date 7/22/2011 Zip 98021 Suspend Date County Snohomish Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PATTEMJ154C8 PATTERSON, MARK J Construction Contractor General Unused 2/28/1985 1/31/2008 Re- Licensed Business Owner Information Name Role Effective Date Expiration Date PATTERSON, MARK Agent 07/22/2005 Bond Amount PATTERSON, MARK Partner /Member 07/22/2005 LPM4075974 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS & SURETY OF MARYLAND LPM4075974 07/11/2008 Until Cancelled $12,000.0007/10 /2008 1 DEVELOPERS SURETY & INDEM CO 547592C 07/11/2005 Until Cancelled 11/20/2008 $12,000.0007/22 /2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Preferred Contractors Ins Co PCIC5025PCA6563 02/01/2011 02/01/2012 $1,000,000.00 02/02/2011 5 Preferred Contractors Ins Co PCIC5025- PCA6563 02/01/2010 02/01/2011 $1,000,000.00 01/26/2010 4 Preferred Contractors Ins Co R 36315 02/01/2009 02/01/2010 $1,000,000.0001 /16/2009 3 PRO-BUILDERS SPEC INS NB59476 02/01/2008 02/01/2009 $1,000,000.0001 /24/2008 2 FIRST SPECIALTY INS CORP FGL22900602960001/31/2006 01/31/2008 $1,000,000.0001 /22/2007 1 AMERICAN STATES INS CO 010E8961996 01/31/2005 01/31/2006 $1,000,000.0007 /22/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 05/09/2011 94' -6' 4 EOBAL - 24' -8' 22. -6- 8' -11' 4 0 5 -41/2' = 21'-6' (E) CONFERENCE ROOM 0 EXISTING WOMENS 0 0 0 0 0 0 VEMENS XISTING (E) ELECTRICAL • PANELS (TYP)ALL CORNERS (1) (E) 8'x3'x8' 'EQUIPTO' STORAGE RACK (TYP)ALL CORNERS (2) (E) 8'x4'x9' (1) (E) 8'x410' 'INTERLAKE' STORAGE RACKS (w) EXI 11NG —I LU CH J U NO WORK IN THIS AREA EXISTING OFFICE 3' -1' 41111 iiM r (TYP)ALL CORNERS (7) (E) 5'SHEL'.' 'RIVET RACK' STORAGE SHELVING B EXISTING SHELVING UNITS AND RACKS TO BE SECURED FOR EARTHQUAKE AS DETAILED ON THIS DRAWING. EXISTING WAREHOUSE EXISTING OFFICE EXISTING OFFICE EXISTING OFFICE OFFICE EXPANSION SEE SEPARATE PERMIT FOR OFFICE EXPANSION. SERVICE COUNTER \o rn SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical I[ Plumbing t(Gas Piping City of Tukwila BUILDING DIVISION FLOOR PLAN 0 2 4 8 16 1111 SCALE 1/8' -1.-0- STRUCTURAL NOTES 1. ANCHOR BOLTS: ALL ANCHOR BOLTS SHALL BE STANDARD STRENGTH. 2. MACHINE BOLTS: ALL MACHINE BOLTS ATTACHING BRACKETS TO SHELF STANDARDS SHALL BE COMMERCIAL GRADE. 3. MISCELLANEOUS METALS: CLIP ANGLES SHALL BE 16 BENT STEEL PLATE, 60 KSI. 4. ALL WEDGE ANCHOR HOLES SHALL BE ACCURATELY DRILLED AND AIR BLOWN TO CLEAN. 5. SEISMIC CATEGORY: "D ". GENERAL BUILDING CODE IBC 2009 AND THE STATE OF WASHINGTON AMENDMENTS TO THE CODE. NO ELECTRICAL, MECHANICAL OR FIRE PROTECTION WORK TO BE PERFORMED UNDER THIS PERMI LEGEND ENERGY CODE NOTES NO ADDITIONAL HEATED OR AIR CONDITIONED AREAS. BUILDING CODE NOTES BUILDING CODE ZONING TENANT AREA OFFICE WAREHOUSE TYPE OF CONSTRUCTION SPRINKLERED IBC 2009 M1 7125 SF 3490 SF 3635 SF III —N 1 WALL TYPES: }4T4*T EXISTING WALL EXISTING DOOR DUPLEX OUTLET > DATA OUTLET EXISTING EGRESS SIGNAGE EXIT PROJECT DATA 1.0 PROJECT DESCRIPTION 1.2 LOCATION 1.3 LEGAL DESCRIPTION 1.4 TUKWILA CDD PROD. # 1.5 TAX PARCEL 1.6 OWNER 1.7 ARCHITECT 1.8 STRUCTURAL ENG. 1.9 CONTRACTOR INSTALLATION OF SEISMIC HOLD DOWNS TO (E) STORAGE RACKS IN WAREHOUSE. 3415 S. 116TH STREET SUITE 103, BUILDING 5 TUKWILA, WA. 98168 REFER TO LEGAL DESCRIPTION ATTACHED TO DRAWING SEPARATELY TBD. 1023049043 RREEF `AMERICA REIT II MMMM7 WA 0/0 CB RICHARD ELLIS /ASSET SER' 1720 GATEWAY DRIVE, SUITE 200 TUKWILA, WA. 98168 JAAKOLArchitecture 3529 BURKE AVE. N SEATTLE, WA. 98103 BRUCE S. MACVEIGH Ps 1425 59TH. AVE. S. I REVIEWS TUKWILA, WA. 98168 CODE COMP TBD. „ APP,RO MAY 03 It rat E1 :Dr 11E y, Green R.rcr 1r, .,Ll 1 1';;h' `n • X9(11 ; n REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. l VICINITY PLAN INDEX OF DRAWINGS Al STORAGE RACK EARTHQUAKE HOLD DOWN AND RESTRAINT PLAN, ELEVATIONS AND NOTES. A2 STORAGE RACK EARTHQUAKE HOLD DOWN AND RESTRAINING DETAILS. FELE C Y= PY Permit No. 1' +..,.. v .• Plan review approval is subject to errors and omissions. kpprmiai of construction docu ' = is d • es not authorize ti . oiation inance. Receipt o; a.pprov -d '` r4 1 . admowledge& B Date: City Of Tukwila BUILDING DIVISION (E) SHELF RACKS INTERLAKE A WEST ELEVATION SCALE 1/4" = 1' -0" EQUIPTO (E) ELECTRICAL JANELS (E) DOOR (7) (E) 5'x2'x10' "RIVET RACK" STORAGE SHELVING B NORTH ELEVATION SCALE 1/4" = 1' -0" P1\- oio \) SHELF RACKS C PARTIAL EAST ELEVATION SCALE 1/4" = 1' -0" DRAWN BY DATE L KJ 3 -14 -11 CHECKED BY DATE DRAWN BY DATE CHECKED BY DATE k-C3.3 m STORAGE RACK SEISMIC HOLD DOWN PLAN, ELEVATIONS AND NOTES r1oi RECEIVED CITY OF TUKWILA MAR 1d2011 PERMIT CENTER "13-14-201 1 SHEET 1 of 2 SHEET Al NOT USED L K J 3 -14 -11 CHECKED BY STORAGE RACK 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 j STORAGE RACK ° o ., ° ° • STORAGE RACK (E) STANDARD (E) STANDARD (E) STORAGE RACK STANDARD 3„ (E) STANDARD (E) BASE SHELF (E) STORAGE RACK STANDARD INTEGRAL BASE PLATE ' (E} STORAGE RACK INTEGRAL BASE PLATE F� �, �3 x5 x6 FABRICATED STL. ANGLE BRACKET W/ 9/16" HOLES. , � E_�L 1 - ' _ +---r '; mid- 1 CO (TYP) (2) 2" x 4 1/2" A.B. J W/ F.W. AND NUTS. f I 'FA ,._ .�.,., i _ L_ 1 4 4 4 4 4 4 41 ,� I (TYP) (2) x 4 1/2" A.B. W/ F.W. AND NUTS. SHEET 2 of 2 (TYP) (2) 2" x 4 1/2" A.B. W/ F.W. AND NUTS. 4 #�--- 01 — , a. • i • . • . , • .. a SECTION DETAIL "RIVET RACK" r 3 SECTION DETAIL - "EQUIPTO" 2 FACE ELEVATION-"INTERLAKE' SIDE ELEVATION - "INTERLAKE" SCALE 3"=1'--0" SCALE 3"=V---0" -0 ,2 SCALE 3"-V-0" -0 SCALE 3"=1'-0" • NOT USED 6 OUTLINE OF BASE SHELF. RACK NOT USED • A 1 1 STORAGE RACK 1 (E) "x5 6 "x7" FABRICATED STL. ANGLE BRACKETS. (E) STORAGE STANDARD 3 (E) STANDARD 3 >> 4 STL. (2)1" x 1 2' MB W/ FW AND NUTS. STORAGE 3 >> /7 16 "x5 "x6" FABRICATED STL. ANGLE BRACKET W/ 9/16" ' HOLES. . (E) STANDARD hI �- RACK (E) MFGR INTEGRAL BASE PLATE W/ (2) " HOLES AS INDICATED " ;;�;,�" ' CO (TYP) (2) 2" x 4 1/2" A.B. W/ F.W. AND NUTS. ,. _ % ' N JI, - .;,�,6.. 3 » 14 Vii I REVIEWED FOR • CODE COMPLIANCE APPROVED MAY 0 3 nil CI Of Tukwila BUILDINr, nIU14Inki . 9 I" " io r ,1 2 3 " 8 �/ 21 4- „ i �"d [}jd (TYP) (2} 2" x 4 1 /2 " A. B. W/ F.W. AND NUTS. ' (TYP) (2) 2 x 1 1 /2 M. B, W /F.W.ANDNUTS wii PLAN DETAIL - "INTERLAKE" (TYP) (1) 2' x 4 1/2" A.B. W/ F.W. AND NUT, 19 PLAN DETAIL - "RIVET RACK" (8 PLAN DETAIL - "EQUIPTO" SCALE 3 " =1' -0" • NOT USED RECEIVED APR 20 2011 PERMIT CENTER CORRECTION es• M$C% LTR# �G o� vas ter SCALE 3 " =1' -0» NOT USED SCALE 3 " =1' -0" NOT USED • • NOT USED STORAGE '- RACK :MAXIMUM . SHELF LOAD LIMITS •RACK.BRAND NAME MAXIMUM-ALLOWABLE LOAD LIMIT PER SHELF RIVET RACK, INC: 700. POUNDS PER SHELF INTERLAKE RACKS 10' °� 4' 3,000 POUNDS PER SHELF 9' X 4' 3,000 POUNDS PER SHELF EQUIP'O RACKS:. S' X 3' 4,000 POUNDS PER SHELF IMPORTANT NOTE: w e ;y - G "t / ,, "EACH RACK MUST BE POSTED WITH APPRORIATE LOAD LIMIT SIGNS ON MINIMUM 5 X 10 PLACARDS" ANCHOR BOLT INSPECTION: VERIFICATION OF ANCHOR BOLT HOLES IN SLAB AND VERIFICATION OF CORRECT ANCHOR BOLT SIZE AND TYP. E. INSPECTION TO BE CONDUCTED BY BRUCE S. MA:CVEIG P.E., ENGINE ' 0 RECORD. : EXPIRES: 4/24/ /� • v 4 Zdfri !an v\.6eAr will tn6ea mvib, .;i■h� \,(Akcir 1Y\ alAci\W \°°\\C ICI6k‘Qa ;1'1a� ihS,V, ovi DRAM BY DATE L K J 3 -14 -11 CHECKED BY DATE STORAGE RACK SEISMIC HOLD DOWN DETAILS 101 DATE 3-14-2011 SHEET 2 of 2 SHEET OF SHEETS .A2