HomeMy WebLinkAboutPermit D11-078 - GRANITE TRANSFORMATIONS - TENANT IMPROVEMENTGRANITE
TRANSFORMATIONS
7100 FUN CENTER WY
Dl 1 -078
City oikukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: htq,://www.ci.tulcwila.wa.us
DEVELOPMENT PERMIT
Parcel No.: 2423049092
Address: 7100 FUN CENTER WY TUKW
Suite No:
Project Name: GRANITE TRANSFORMATIONS
Permit Number: D11 -078
Issue Date: 04/18/2011
Permit Expires On: 10/15/2011
Owner:
Name: H2 OFFICE LLC
Address: 7100 FUN CENTER WAY STE 100 , TUKWILA WA 98188
Contact Person:
Name: JOLEE CONVER
Address: 20725 NE 38 ST , SAMMAMISH WA 98074
Contractor:
Name: GRANITE TRANSFORMATIONS /KNG CO
Address: 219 S HORTON , SEATTLE WA 98134
Contractor License No: GRANITK951KC
Phone: 425 985 -9687
Phone: 206 - 217 -2500
Expiration Date: 08/09/2011
DESCRIPTION OF WORK:
ADD NEW TENANT PARTITIONS/WALLS AND INSTALL 6 INCH HIGH DISPLAY PLATOFROM. NEW CARPET AND /OR TILE
FLOORING IN SOME DISPLAY AREAS WITH THERE BEING NO CHANGES TO THE BUILDING STRUCTURE.
Value of Construction: $5,500.00 Fees Collected: $338.46
Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009
Type of Construction: VB Occupancy per IBC: 0019
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D11-078 Printed: 04 -18 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Size (Inches): 0
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
1/4,)
Private:
Profit: N
Private:
Public:
Non- Profit: N
Public:
Date: 4_4 gam' (, 1
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
(I r
to this permit.
Signature:
Print Name:
Date:
f-
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced
to the building structure.
doc: IBC -7/10
D11-078 Printed: 04 -18 -2011
7: All construction shall be done in conform- with the approved plans and the requirem *of the International
Building Code or International Residential , International Mechanical Code, Washingt to Energy Code.
8: Manufacturers installation instructions shall be available on the job site at the time of inspection.
9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
13: ** *FIRE DEPARTMENT CONDITIONS * **
14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4 -4)
20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
doc: IBC -7/10
D11-078 Printed: 04 -18 -2011
the principal strokes of the letters not less th 0.75 inch (19.1 mm) wide. The word "EXIT" s have letters having
a width not less than 2 inches (51 mm) wide pt the letter "I ", and the minimum spacing een letters shall not be
less than 0.375 inch (9.5 mm). Signs larger tha the minimum established in section 1011.5.1 the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
27: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1
foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor
level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point
of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination
uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4)
28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
29: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinkler heads. (1FC 901.4)
30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer
licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance No. 2050).
32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require
relocation and/or addition of audible /visual notification devices. (City Ordinance #2051)
33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite,
room or apartment number in a conspicuous place near the main entry door. (IFC 505.1)
38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
39: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed
description of intended use.
40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: IBC -7/10
D11-078 Printed: 04 -18 -2011
CITY OF TUKWIND
Community Developilirnt Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www. ci. tkwila. wa. us
Building Pernifo.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 7/ CO j:7jA/ CW'e WAX.
King Co Assessor's Tax No.: 21i9----3)04- 1 (12_
Suite Number: 730 Floor: 4-M3O
New Tenant: Yes ❑.. No
Tenant Name: 4.R.40/ Y/r 724 sreyrnArlaisic
Property Owners Name: N 2 OBE"/ a */ L L C IOa
Mailing Address: 7&V 7t2,V 6j j// E u'/A/ S(J /yt
TvkWIe.,c
City
WA I8/813
State Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: f0 LEE CON V ( Day Telephone: (.2) %95 9'687
Mailing Address: 20.72 Nt 3342. Sr; ,5'A.14/'1 1 /SI/ WA YX 7¢..
City E -Mail Address: 101-Ewe q T$6. 4 rTL 6 • con Fax Number: (2 J 2/ 7 25-0
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
/ •
L� 1 .1! 4d
/
♦4
0
Mailing Address: e 0725. A/E 39//,, ST Cdr/ fi4M /SLy wA !/JO %f
City State Zip
Day Telephone: (t2 . 78C 9677
Fax Number: reo6) 2/ 7 250/
Expiration Date: ,4 /)c -,,. B, 20//
Contact Person: COL .iOf yE,�
E -Mail Address: TOL EEC C°TSEATT L,E I Can
Contractor Registration Number: ('g4N /T1(? 37 KC
ARCHITECT OF RECORD — All plans must be stamped by Architect of Record
Company Name: G Lj W,ee/I/'6 Ai; C ttAr eZ _
Mailing Address:Jj` // Sa v' /87)4. PLAGA-
Contact Person: ZAWRcf/VCE
E -Mail Address: 1.M CA RCN/ rTCT c COMC4 ST, NET"
R &i V A/ WA ygo58 -7r/
City State Zip
Day Telephone(4i75) 2 5j77�
Fax Number:
ENGINEER OF RECORD — All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
State
Zip
E -Mail Address:
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 6
BUILDING PERMIT INFORMATION — 206 - 431 -3670
Valuation of Project (contractor's bid _ ): $ c5-09 --^ Existin uilding Valuation: $
Scope of Work (please provide detailed information):
FA
Will there be new rack storage? ❑ ....Yes
❑ ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No if "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11 " paper including quantities and Material Sa ety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:1Applications\Forms- Applications On Linet2010 Applications17 -2010 - Permit Application.doc
Revised: 7-2010
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
98.77
2, / !�
TYPE
G
V P.6
M
/ ,
rd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No if "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11 " paper including quantities and Material Sa ety ata Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:1Applications\Forms- Applications On Linet2010 Applications17 -2010 - Permit Application.doc
Revised: 7-2010
bh
Page 2 of 6
PUBLIC WORKS PERMIT INFOOTION — 206 -433 -0179
1
Scope of Work (please provide detailed information): ,4 PO New TENANT- PA.T /TIoA/ W 4
J/ISTALLA -T /O V OF 6 hvoii HI Di5R4y P64TFo/W p 2 P644'
Nt W s/ c,4'A y-E rSS•P4,eATC A Z/t1ITJ A/& IW CARA r /5JL Tike
iA,/
S
C� •_eiS,.S
Call before you Dig: 1- 800 - 424 -5555
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
Tukwila ❑ ...Water District # 125 ❑... Highline
.. Water Availability Provided
ewer District
.. Tukwila
.. Sewer Use Certificate
❑ ...Valley View . El... Renton
❑ ...Sewer Availability Provided
❑... Renton
❑... Seattle
Septic System:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ")
❑ .. Technical Information Report (Storm Drainage)
❑ .. Bond ❑... Insurance ❑... Easement(s)
Proposed Activities (mark boxes that anoIv):
❑ .. Right -of -way Use - Nonprofit for less than 72 hours
❑ .. Right -of -way Use - No Disturbance
El.. Construction/Excavation /Fill - Right -of -way ❑
Non Right -of -way ❑
❑ .. Total Cut
o .. Total
cubic yards
cubic yards
❑ .. Sanitary Side Sewer
El.. Cap or Remove Utilities
El.. Frontage Improvements
El.. Traffic Control
❑ .. Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Permanent Water Meter Size..
❑ .. Temporary Water Meter Size .
El.. Water Only Meter Size
❑ .. Sewer Main Extension Public ❑
El.. Water Main Extension Public ❑
❑.
❑.
❑.
❑.
❑... Geotechnical Report
0... Maintenance Agreement(s)
El.. Traffic Impact Analysis
❑ .. Hold Harmless — (SAO)
El.. Hold Harmless — (ROW)
El... Right-of-way Use - Profit for Tess than 72 hours
❑... Right -of -way Use — Potential Disturbance
El... Work in Flood Zone
❑... Storm Drainage
.. Abandon Septic Tank
.. Curb Cut
.. Pavement Cut
.. Looped Fire Line
WO #
WO #
WO #
Private ❑
Private ❑
El... Grease Interceptor
❑... Channelization
❑ ... Trench Excavation
❑... Utility Undergrounding
❑ .. Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
❑ .. Water El.. Sewer ❑ .. Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
City State Zip
Water Meter Refund/Billing:
Name:
Mailing Address:
Day Telephone:
City State Zip
H:\Applications\Fornu- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 3 of 6
MECHANICAL PERMIT INFORMATION — 206 - 431 -3670
MECHANICAL CONTRACTOR INF RMATION ((xis rc s ySTFTn 7I M.R /N ANA- Al
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Mechanical work (contractor's bid price): $
Scope of Work (please provide detailed information):
Use: Residential: New.... ❑ Replacement.... ❑
Commercial: New.... ❑ Replacement.... ❑
Fuel Type: Electric ❑ Gas.... ❑ Other:
Indicate type of mechanical work being installed and the quantity below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace<100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Furnace>100K BTU
Evaporator Cooler
Diffuser
3 -15 HP /500,000 BTU
Floor Furnace
Ventilation Fan Connected
to Single Duct
Thermostat
15 -30 HP /1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30 -50 HP /1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1,750,000 BTU
Repair or Addition to
Heat/Refrig/Cooling
System
Incinerator - Domestic
Other Mechanical
Equipment
Air Handling Unit
<10,000 CFM
Incinerator — Comm/Ind
H: Applications1Forms- Applications On Line12010 Appiications17 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 4 of 6
PLUMBING AND GAS PIPING PER. INFORMATION — 206 - 431 -3670
•
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION fietker 6j«S'f/ v rt�i . pev/oof
Company Name: PeiQMI7 -- 7r' /2&/4//1( eiNC ✓,4w'gez%)
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'I Building Code): f%f sI y,,c( y / ,eiF -yAi QUTLFT �7Z
Occupancy (per Int'l Building Code): Al ri fene4vt/j7
Utility Purveyor: Water: / Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 5 of 6
PERMIT APPLICATION NOTES — Illicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature:
Print Name:
AUTHQRIZED AGENT:
LTFoL e Cf)r) V
Mailing Address: 2 O 771
Date: .-I 2S ),1 /
Day Telephone: - �� 6B7
21%11 rvtQ1'n cS (Ai 4 9 )7�
City State Zip
IDate Application Accepted:
Date Application Expires:
Staff Initials:
H:\ApplicationsTorms- Applications On Line12010 Applications1.7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 6 of 6
11110 410
wq� City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www. ci. tukwi la. wa. us
RECEIPT
Parcel No.: 2423049092 Permit Number: D11 -078
Address: 7100 FUN CENTER WY TUKW Status: PENDING
Suite No: Applied Date: 03/25/2011
Applicant: GRANITE TRANSFORMATIONS Issue Date:
Receipt No.: R11 -00586
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $338.46
Payment Date: 03/25/2011 04:02 PM
Balance: $0.00
GRANITE TRANSFORMATIONS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1652 338.46
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $338.46
202.40
131.56
4.50
doc: Receiot -06 Printed: 03 -25 -2011
INS'ECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
• l-O7g
CITY OF TUKWILA BUILDING DIV
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431 -2451
Project: t
Type of Inspection: rp .
Address(
Date C�Flec� :/the
(
Special Instructions:
Date Wanted: ' /' ( a.m.
Requester:
Phon No:
zs -Iss —5%0.3'7
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
rf Art- (.4ktptap
a8-14oxicA. g
1,) -`1 A IN- A .t.(
Inspector:
Date:
•
r7 REINSP N FEE REQUIRED Pri r to
. next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
w
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION It"
6300 Southcenter Blvd., #1'00, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line ('206) 431 -2451
DU- 0`1
Project: ,,,.,,,1/44,7,-c- 1 Y ,i.qJ
Type f Inspecctio n: & ,
Address:
1 WO
Date Called:
Special Instructions:
0 S� 9 S- V r
Date Wanted: S _r /a.m�
p.m.
Requester:
-roto
Phone No: /
475 -rh v -6/55
Approved per applicable codes.
['Corrections required prior to approval.
COMMENTS:
Inspector:
Date:
•
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 600 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPEC IQN NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd.; #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Prroiect: r-'>S
CI r v� l7,va,JbrJ i J
Type of spection: i.
Hr A,A•& , A_G,
Address:
ate Called:
Special Instructions:
p-4 3
Date Wanted:
.4_
"2,6 — y
a.m
'''.rn.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
n
r
A{ p A-(
1
1
.,n .s-t ct. aAP t rak G P !k S 40 �r ear G,J
Inspector:
Date J
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid•at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
�wae.,....a.,. :5...._A� _;n
'r- �l
- INSPECTION NUMBER
cn� 'xaY�• -e ..p .
INSPECTION RECORD
Retain a copy with permit
/1 -4- -o3$
0 -7C5
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Project:
Ayl 4 3. 40 vt5
,-wv'I c 0d
T e of s pect :
-Iii- Y\ +0 04 2—____
-- A 5 ( -
Address: --7,a o 47./ ,jce,
Suite #: /3v
�s �
eonta Perso
Special Instructions
/
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
}
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
— -JAL
ok-
r t
C. N OL
og-
,
/
Needs Shift Inspection:
}
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: S--
Date: 40s f/t
Hrs.:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
1 Company Name:
Address:
City:
State: 1 Zip:
Word /Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
•
•
•
�.r
•
•
•
•
•
ti
.1
•r
,.9
.4
•
•
•
IERMITC04RDCOPI1111
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -078 DATE: 03/25/11
PROJECT NAME: GRANITE TRANSFORMATIONS
SITE ADDRESS: 7100 FUN CENTER WY, STE 130
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
EPARTMENTS:
Cl ding ivision
Public Works
Il e Prevention
Structural
Planning Division
Permit Coordinator
El
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
LY1
Complete
Comments:
Incomplete
DUE DATE: 03/29/11
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES /THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 04/26/11
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople P ter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name GRANITE TRANSFORMATIONS /KNG
CO
Phone 2062172500
Address 219 South Horton
Suite /Apt.
City Seattle
State WA
Zip 98134
County King
Business Type Corporation
Parent CONVER CORPORATION
Company
UBI No. 602464384
Status Active
License No. GRANITK951KC
License Type Construction Contractor
Effective Date 8/9/2005
Expiration 8/9/2011
Date
Suspend Date
Specialty 1
Tile, Ceramic, Mosaic, Natural And
Mfg Stone
Specialty 2 Unused
Other Associated Licenses
License
Name
Type
Vp
Specialty 1
p y
Specialty
2
Effective
Date
Expiration
Date
Status
GRANIT *927DD
GRANITE
TRANSFORMATIONS /SPOKAN
Construction
Contractor
Floor
Covering
And
Counter
Tops
Unused
3/3/2008
3/5/2012
Active
GRANITC962J3,TRANSFORMATIONS
GRANITE
/KG CTY
Construction
Contractor
Resilient
F /Counter
M /Plastic
Other
(Specify)
5/4/2004
5/4/2006
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
CONVER, ANTHONY
President
05/03/2005
Bond Amount
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
AM STATES INS
6554925
10/21/2008
Until Cancelled
$6,000.0010/27/2008
10/01/2010
2
AMERICAN STATES INS
6554925
03/31/2008
10/21/2008
$6,000.0010/07/2008
10/01/2010
1
CBIC
SG2591
08/08/2005
Until Cancelled
10/02/2008
$6,000.0008/09/2005
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
TRAVELERS
INSURANCE CO
6804005R329
10/01/2010
10/01/2011
$1,000,000.00
10/01/2010
4
AMERICAN
STATES INS CO
01CG9256612
10/01/2008
10/01/2011
$1,000,000.00
10/01/2010
3
AMERICAN
STATES INS CO
01CG9256612
10/01/2007
10/01/2008
$1,000,000.0009
/26/2007
2
SAFECO
AMERICAN
STATES INS
01CG925661 2
10/15/2005
10/15/2008
$1,000,000.0009
/20/2007
https://fortress.wa.gov/lni/bbip/Print.aspx
04/18/2011
•
Property Line
•
•
-`Jet
oce
• .•.".
•
�r
1
•aoe 1'
PLANNiNG APPROVED •
No changes .can be made to these
plans without approval from the
Planning Division of DCD
Approved
[Date:
SEPARATE PERMIT
REQUIRED FOR:
iJ Machanlcal
ladi Electrical
f 'Plumbing
GM Ptping
City 0f as Tukwlta
BUILDiNG DIVISION
... 2; 1:•'
�• t•. ,j..• •s Z J•'U •
hs all be ma.:7 to the scope
�� :�zot�Driar approval of
s!, a Burdiri IDivisian.
may include
will
plan review tees.
.L Property Line
• s`b=
Exist!
Imo.
• , Line of ordinary ,
high waters.-'
/' 40' Offset from
r'
ordinary g
,./ water line
21' Light Pole
,I J
r-
,,
�,
. G `ry
Existing
standard
Drain to
Sanitary Sews
,,1 21' Light Pole.
1
/
Asphalt • ?'
rty Line
/
with
guredetom
e plan.
ML)
New •
striping
sting Asphalt
Light.
standard `e ton 0.63
'NBW�
Property Line r
•
•y
Power
easement
Light9
standard •,
•
Existing
Light
standard
♦z
100' Offset from
ordinary high
water line
21' Light Pole
r
•
200' Offset from ,
ordinary high
water line --•j'
• Futur+eN
sidewalk •
X ht
MN WS
Property Line
Landscape ``• --
•
Buffer
21 ygh
u Cen t er 'we>
Light standard/
underground power,
SITE PLAN for GRANITE TRANSFORMATIONS SCALE: 1° = 30' -0'
TOTAL NUMBER OF PARKING SPACES REQUIRED FOR THIS TENANT SPACE IS SIX (6 )
( BASED ON 2 1/2 SPACES PER EACH 1,000 SQUARE FEET OF GROSS AREA )
TOTAL NUMBER OF PARKING SPACES ASSIGNED TO THIS SPACE IS NINE (9)
441/4
VICINITY MAP nts
BIDDER DESIGN
SYSTEMS:
DRAWING INDEX:
t ELECTRICAL ( REQUIRES SEPARATE PERMIT )
2. MECHANICAL ( HV &AC ) ( REQUIRES SEPARATE PERMIT )
3. PLUMBING ( REQUIRES SEPARATE PERMIT )
4. BUILDING SPRINKLER & FIRE ALARM SYSTEM ( REQUiFIES SEPARATE PERMIT )
( BUILDING FIRE PROTECTION SYSTEM, INCLUDING BUT NOT UMITED TO
AUTOMATIC BUILDING SPRINKLERS & FIRE ALARMS SHALL BE DESIGNED & INSTALLED PER
1.0.0. CHAPTER 9 IF EXISTING SYSTEM 18 MODIFIED).
6. ALL SUPPLIERS OF PRE - MANUFACTURED EQUIPMENT
SHALL PROVIDE SPECiFtCATIONEQUIPMENT OPERATION
INFORMATION TO THE TENANT PRIOR TO INSTALLATION
OF SAID EQUIPMENT, & SHALL ALSO PROVIDE SCHEDULED
MAINTENANCE & WARRANTY INFORMATION WHERE APPROPRIATE.
8. INSTALLATION OF BUILDING SIGNS ( REQUIRES SEPARATE PERMIT )
ARCHITECTURAL. DRAWINGS
A -1.0 COVER SHEET, SITE PLAN, VICINITY MAP, DRAWING INDEX, LEGAL DESCRIPTION, ETC.
A -2.01 (OVERALL BUILDING FLOOR PLAN ( NO REVISIONS TO EXTERIOR WALLS )
A -2.2 'REMODELED FLOOR PLAN ( TENANT IMPROVEMENTS )
A-5
MISCELLANEOUS DETAILS
CODE REFERENCES & BUILDING STATISTICS
I. OCCUPANCY GROUP: M ( MERCANTILE ) PER i.B.C. SECTION 309
2. EXIST'G BLDG CONSTRUCTION CLASSIFICATION TYPE V-B ( SPRINKLERED PER I.B.C. SECTION
3. APPLICABLE CODES: ( CURRENT EDITION OF ALL OF THE FOLLOWING )
AMERICAN NATIONAL STANDARD ( ICC /ANSI M17.1 -2003 )
INTERNATIONAL BUILDING CODE ( 2009 EDITION )
WASHINGTON STATE BUILDING CODE ( 2009 EDITION ) CHAPTER 61-60 WAC
INTERNATIONAL MECHANICAL CODE ( 2009 EDITION )
INTERNATIONAL FIRE CODE (2009 EDITION )
UNIFORM PLUMBING CODE ( 2009 EDITION )
WASHINGTON STATE ENERGY CODE ( 2000 EDITIOP4 ) CHAPTER 61 -11 WAC
WASHINGTON STATE INDOOR AIR QUALITY CODE ( 2009 EDITION .)
NATIONAL ELECTRICAL CODE ( CURRENT EDITION )
EACH OF THE RELATED STANDARDS & STATE AMENDMENTS TO THE GODES USTED ABOVE ( LATEST EDITIONS
CITY OF TUKWILA MUNICIPAL CODE
COVER SHEET NOTES
( GROSS LEASE AREA )2,198.11 SO. FT.
PROJECT DESCRIPTION:
602.6 & TABLE 831 )
THE GRANITE TRANSFORMATION SPACE IS TO BE USED AS
A DISPLAY /RETAIL OUTLET STORE FOR GRANITE COUNTER-
TOPS, BATHING TUB & SHOWER COMPARTMENT SURROUNDS,
& 18 OPEN TO THE PUBLIC EITHER BY APPOINTMENT OR BY
DROP -IN RETAIL SHOPPERS.
THERE WILL BE A SMALL STAFF OF EMPLOYEES IN THE
STORE TO PROVIDE ADVICE ON THE USE OF THE GRANITE
PRODUCTS, AS WELL AS TO PROVIDE THE CUSTOMER WITH
COMPETITIVE PRICE BIDS FOR COMPARATIVE SHOPPING.
THE PRODUCTS ARE INTENDED FOR UBE PRIMARILY IN THE
RESIDENTIAL MARKET FOR EITHER NEW OR REMODELED
PROJECTS. THE PRODUCT 13 STORED, SHIPPED & INSTALLED
BY CREWS FROM A SEPARATE OFF -SITE LOCATION. THIS
FACILITY. IS PRIMARILY A SHOWROOM FOR THE PRODUCTS.
REFER TO THE SCOPE OF WORK STATEMENT ON THE RE-
MODELED FLOOR PLAN DRAWING ON SHEET A -2.2 FOR
ADDITIONAL INFORMATION ON THE WORK.
LEGAL DESCRIPTION:
(AS SHOWN ON SURVEY BY CENTRE POINTE SURVEYING DATED 5/6/03)
THAT PORTION OF
THE WEST HALF OF SECTION 24, TOWNSHIP 23. NOR. F H O7�MERIDIAN, KING COUNTY
WS N EAST M 4 AAK I I U Yo t UiW QL ;:
COMMENCING AT THE INTERSECTION OF 711E 2M-LINE OF PRIMARY *STATE
HIGHWAY NO. :4 GREEN RIVER iN1'ERCHANG ALL AS CONVEYED TO' OR
'CONDEMNED BY 114E STATE OF WASHINGTON BY DEEDS RECORDED UNDER
KING COUNTY RECORDING NOS. 5499612. 5507291 5510773. 5503778, '
5536582. AND S UNDER XiNG COUNT SUPr:R10R COURT USE
NO. 588089. STA POC (2M 134+28.58. WITH THE A-LINE STA POT A
102+82.2 AS SHOWN ON THAT CERTAIN MAP ON FILE WrTH THE STA
OF WASHINGTON DEPARTMENT OF TRANSPORTATION LABELED SR 405 GREEN •
RIVER INTERCHANGE R1GWr OF WAY STA 99+00 TO • STA 120+00. SHEET 2
OF 2, APPROVAL DATE OF JANUARY 30, 1962, WITH LAST REVISION DATE •
OF DECEMBER 31, 1992
THLICE NORM 42'30'02" EAST ALONG THE CENTERLINE OF SAID ALINE,
80.55 FEET TO STA 103+70.67 OF SAID A-UNE:
THENCE NORTH 4729'5588'"" WEST. 60.00 FEET TO A POINT ON THE NORTHERLY
RIGHT OF WAY SAID PRIMARY STATE HIGHWAY NO. 1 • SAID POINT. BEING
THE BEGINNING OF A CURVE .CONCAVE TO THE SOUTH WITH A RADIUS OF
183.00 FEET. AND ALSO BEING THE TRUE POINT OF BEGINNING:
THENCE NORTHERLY.. EASTERLY AND SOUTHERLY ALONG SAID RiCHT OF
WAY ON THE ARC OF SAID CURVE THROUGH A CENTRAL ANGLE OF 64'48'29"
A DISTANCE OF 184.37 FEET;
THENCE LEAVING SAID RIGHT OF WAY, AND BEARING NORTH 2114'11"
EAST, 38.16 FEET: '
THENCE NORTH 84'411'08" V ST, 5.90 FEET;
'HENCE NORTH 22`51 18' WEST, 166.10 F1 ET:
ORDINARY HIGH WATER UNE OF THE FEET PONT R. ON AS ITEWAS •
MAPPED BY' BARGHAUSEN CONSULiING ENGIN S INC. ON AUGUST 11. 1997;•
THENCE FOLLOWINGQCOURSES AND DISTANC> , WATER LJNE bF SAID RIVER THE
SOUTH 70'00100.73`00F00" - , 39.06 FEET;
65.00 .FEET
THE ICE SSOOUTTH H 6700 0" WEST i� 100.00 FEET; • •
THENCE SOUTH 5740eOD" W 30.08 FEET;
THENCE SOUTH 65'50'00' IiVFST. 3300 FEET:
THEE SOUTH 5630'CD" WEST. 100.00 FEET;
THENCE SOUTH 51'00'00" WEST. 50.00 FEET
THENCE SOUTH 35'40'00" VEST. 40.00 Fe*
THEME sotrnr S9'GO'QO" WEST. 80000 F€E7; -
THENCE SOUTH 52•0'00" '11r5T. 50.00 FEET TO THE NORTHEASTERLY RIGHT
OF WAY FOR SAID 2M -UNi~
THENCE SOUTHERLY ALONG SAID RIGHT OF WAY UNE TO ITS INTERSECTION
1'ti411.I THE NORTHERLY RIGHT OF WAY OF SAiD A--UN
THENCE NORTH 4230'02 EAST ALONG SAiD NORTHERLY RIGHT OF WAY.
L42 FEET 7D THE POINT GF• BEGINNING.
T
•
G KNOWN AS adjtated Parcel 1 of Boundary LSne Ad Mmertt No.
recorded under Recording No. B9D6309017).
SITUATE In the County. of. King. State of Washington.
FILE COPY
Permft No.
PI>'n review approval is subject to errors and omissions.
A p; roml of construction documents does not authorize
VI( Violation of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
City Of T1bkwita
BUILDING DIVISION
- REVIEWED FOR
ODE COMPLIANCE
Ipp OVED
• APR 14 2uii
City of Tukwila
BUILDING nivirInni
RECEIV
CINOFTU LA
MAR 2 5 2011
PERMIT CENTER
W
cc
O
Fon
co
J
F
W
cr
Z
O
Pas
scc
Oung
co
cr:
Z
GRANITE
TUKWILA, WA
7100 FUN CENTER WAY -a
2
Approved By
s
c
0
t
Q
0
i
f
z
JUE3 NUM5ER'.:
2071
DRAWING DATE 3/25/2011
COVER SHEET for GRANITE TRANSFORMATIONS
I00'
10'
24' -2'
25'
25'
24' -2'
10'
1' -8 1/4'
7' -4 1/4' $'--11 7/8'
1' -4'
31' --11 5/8'
9' 16' -8'
16' -8'
5' -4'
MECHANIICAL & ELECTRICAL SPACE
J
0
COL.
SUBWAY SANDWICH SHOP
9,
iet
co
a
SUNRISE DENTAL_
DENTAL CIiNIG)
i
10'
24'_2'
COL
EXIST'G COL,
BAJIO MEXICAN GRILL
( RESTAURANT )
WALL
EXISTING TENANT
i— SEPARATION WALL
TO REMAIN
Co Co
-J
-J
EXISTING TENANT
SEPARATION WALL
TO REMAIN
EXIST'G COL;
EXISTING TENANT
SEPARATION WALL
TO REMAIN
VACANT SPACE
EXISTING TOILET ROOM
INSTALLED UNDER
PREVIOUS PERMIT
TO REMAIN
EXISTING EXTERIOR WALLS,
DOORS, & WINDOWS TO REMAIN
INSTALLED UNDER PREVIOUS PERMIT ---"�
Nj
0
EXIST'G TO REMAIN
10' x 10' SECTIONAL
HI -LIFT ALUM.
& GLASS DOOR
a
'0
0
w
EXTENT OF TENANT IMPROVEMENT LEASE AREA
EXISTING EXTERIOR WALLS,
DOORS, & WINDOWS TO REMAIN
INSTALLED UNDER PREVIOUS PERMIT
9
is
•
z Cr
Cu
N
18' -8' 6'-4'
100'
10'
10` -8' _ } 14' -4'
IS-
24, ^2'
10'
0
'-,
OVERALL BUILDING FLOOR PLAN ( NO REVISIONS TO EXTERIOR WALLS ) scale 1/8" = 1' -0"
NOTICE TO ALL PERSONS PERFORMING WORK ON THIS PR QJECT
PRIOR TO THE COMMENCEMENT OF ANY AND ALL WORK ON THIS PROJECT, IT SHALL BE THE
RESPONSIBILITY OF ALL PERSONS PERFORMING WORK ON OR SUPPLYING MATERIALS TO THIS
PROJECT TO COMPLETELY FAMILIARIZE THEMSELVES WITH ALL CODES AND ORDINANCES PERTAINING
TO THAT PORTION OF THE PROJECT WHICH THEY ARE TO PERFORM WORK OR SUPPLY MATERIALS.
SAID WORK OR SUPPLY OF MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND
ORDINANCES. IF ANY PORTION OF THE DRAWINGS, NOTES, OR SPECIFICATIONS ARE NOT IN
CONFORMANCE WITH SAID APPLICABLE CODES AND ORDINANCES, IT SHALL BE THE RESPONSIBILITY
OF EACH AND EVERY PERSON PERFORMING WORK ON, OR SUPPLYING MATERIALS TO THAT NON-
CONFORMING PORTION OF THE PROJECT TO IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF
THE DISCREPANCY BETWEEN THE DRAWINGS AND APPLICABLE CODES AND ORDINANCES. IT SHALL
THEN BE THE RESPONSIBILITY OF THE ARCHITECT TO IMMEDIATELY MAKE CORRECTIONS TO THE
DRAWINGS AS REQUIRED TO BRING DRAWINGS INTO CONFORMITY WITH SAID CODES AND ORDINANCES.
THE ARCHITECTS CORRECTIONS SHALL BE MADE WITH EXPEDIENCY SO THAT THE WORK OF OTHERS
CAN PROCEED WITH THE LEAST INTERRUPTION TO THE PROJECT.
IT SHALL BE THE RESPONSIBILITY OF ANY PERSONS OR SUB - CONTRACTORS PERFORMING WORK ON,
OR SUPPLYING EQUIPMENT OR MATERIAL ( HEREINAFTER REFERRED TO AS WORK ) TO THIS PROJECT
UNDER A SEPARATE AGREEMENT OR CONTRACT WITH THE OWNER TO COMPLY WITH ALL CODES AND
ORDINANCES THAT EFFECT THE OWNERS INTENDED USE OF THE PROJECT. W THE PERFORMANCE OF
SAID WORK SHALL REQUIRE ALTERATION OR MODIFICATION OF THE PROJECT, THEN SAID WORK
SHALL NOT BE PERFORMED WITHOUT FIRST HAVING THE OWNER'S WRITTEN AUTHORIZATION TO
PROCEED, AND THIS AFTER FULLY DISCLOSING TO THE OWNER WHAT FINANCIAL AND OTHER
OBLIGATIONS SHALL BE REQUIRED OF THE OWNER AS A RESULT OF SAID WORK.
WHERE EXISTING CONSTRUCTION OR CONDITIONS ARE IN PLACE ON PROJECT SITE OR ON PREMISE
IN ANY MANNER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY LOCATION,
TYPE OF CONSTRUCTION, AND ANY OTHER CONDITIONS THAT WILL HAVE AN EFFECT ON THE NEW
CONSTRUCTION AS TO ITS LOCATION, SIZE, CLEARANCE. STRUCTURAL INTEGRITY, ETC.. ANY DIS-
CREPANCIES FROM WHAT IS SHOWN ON THE DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE ARCHITECT IN WRITING SO THAT HE MAY INVESTIGATE SAID DISCREPANCIES,
AND MAKE CORRECTIONS TO THE DRAWINGS AS MAY BE REQUIRED, OR TO MAKE OTHER REMEDIES
AS REQUIRED.
II -o1�
2,198.77 SQ. FT.
C GROSS LEASE AREA )
SCOPE OF WORK STATEMENT:
REVIEWED FOR
CODE COMPLIANCE
APR 14 2011
City of
Tukwila
BUILDING fIVISIOM
1. ACCESSIBLE TOILET ROOM IS EXISTING UNDER PREVIOUS PERMIT
2. FURRING ON INTERIOR SIDE OF EXTERIOR WALLS TO CONCEAL- COLUMNS,
WALL BRACING, & OTHER EXPOSED STRUCTURAL COMPONENTS & HARDWARE
tom► EXISTING UNDER PREVIOUS PERMIT
ALL EXISTING EXTERIOR WALL .CONSTRUCTION TO REMAIN UNCHANGED
8' .
24'
16'
48'
TRANSFORMATION RETAIL STORE
GRANITE
71.00 FUN CENTER WAY - TUKWILA, WA
Date
Approved By
c
0
0
N
m
0
c
0
'o
0
ce
0
z
Job Number
2071
OMBRA
OF TIJ LA
MAR 2 5 2011
PERMIT CENTER
3/26/2011
Sheet Number
A -2.01
Of
SCOPE OF WORK STATEMENT:
1. ADD TENANT PARTITION WALLS PER PLAN
2. ACCESSIBLE TOILET ROOM IS EXISTING UNDER PREVIOUS PERMIT
3. FURRING ON INTERIOR SIDE OF EXTERIOR WALLS TO CONCEAL COLUMNS,
WALL BRACING, & OTHER EXPOSED STRUCTURAL COMPONENTS &
HARDWARE IS EXISTING UNDER PREVIOUS PERMIT
4. ALL EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN UNCHANGED
5. ELECTRICAL & MECHANICAL SYSTEM MODIFICATIONS SHALL BE INSTALLED
BY SEPARATE PERMITS. ( INCLUDING LIGHTING REVISIONS )
6. ALL SIGNAGE ( ON BUILDING OR SITE ) SHALL BE INSTALLED BY
SEPARATE PERMITS.THIS INCLUDES A- BOARDS, STICK SIGNS,
FLAGS, ETC.
7.. INSTALLATION OF 6 INCH HIGH DISPLAY KITCHEN PLATFORM
8. ALL TENANT SEPARATION WALLS ARE EXISTING AND WERE INSTALLED
UNDER PREVIOUS PERMIT.
EXISTING TOILET
ROOM WALL
23/32 T &G PLYWOOD
SUB -FLOOR OVER.
RAISED PLATFORM - FRAMED W/
PRESSURE TREATED 2x4 SLEEPERS
ON EDGE @ 16' Q.C.
PRESSURE TREATED 2x4 SLEEPERS
ON EDGE PERIMETER FRAMING
EXIST'G COL.
6
_ 9' -1 5/8'
11' -11 1/2"
15' --10 3/8'
RAISED PLATFORM FRAMING PLAN
Scale: 1/4` � 1' -04
NEW 6* WIDE STEEL FRAMING STUD NOTE:
THE TOP OF ALL NEW STEEL STUD WALLS SHALL BE FRAMED TO
A HEIGHT OF 8'-0" ABOVE TOP OF EXISTING FLOOR SLAB UNLESS
NOTED OTHERWISE.
DRAWING LEGEND:
T.S. DET.- --5
E.Lb
LOCATION OF VERTICAL TUBE STEEL
PARTITION /WALL STIFFENERS REFER
TO SHEET A-6 FOR DETAILS.
EXIT PATHWAY LIGHTING FIXTURES
MOUNTING HEIGHT 8' -10" ABOVE FIN. FLOOR
LIGHTS ARE EXIST') IN LOCATIONS SHOWN
ON FLOOR PLAN
EXISTING STRUCTURAL FRAMING GRID LINE
36' CLEAR WIDE PATH OF EGRESS
LEADING TO REQUIRED EXITS
F.O.s. ----- DIMESIONED TO FACE OF STUD
1
DIMESIONED TO FINISH FACE OF WALL
C. COL,
Co COL.
EXIST'G COL.
(NOTAPART)
NOT A PART )
C. WALL
12'-8 1/8'
6'
EXISTING TENANT
SEPARATION WALL
TO REMAIN
F.O.S.
I3'-1 1/4"
F.O.S.
EXIST'G WALL
EXISTING
ELEC, PNL.
F.O.S.
EXISTING COL.
t EXIST'G ) W.C.
SEATING AREA
IDEA CENTER
BUSINESS
OFFICE
C EXIST'G )
19x17 LAV.
C EXIST'G > LEVER
HARDWARE BOTH
SIDES OF DOOR
EXIST'G WALL
EXISTING TENANT
SEPARATION WALL
TO REMAIN
C. EXISTING PLUMBING
cc
LL
O
z
e.d
FRAMED
HEADER
OVER
3'--1 3/4' 4'
F.O.S.
fir rig .��rr.�.�.rrrrrrrrrFf.��'.�.ft'
T.S. DET,
3°x 7°
CASED IUPN'G,
6' -0 3/16"
3'--6"
F.O.S.
RAISED PLATFORM - FRAMED W/
PRESSURE TREATED 2x4 SLEEPERS
ON EDGE W/ 23/32 T &G
PLYWOOD SUB -FLOOR OVER.
ENGINEERED WOOD FIN. FLOORING OVER.
REFER TO PLATFORM FRAMING DETAIL
ON THIS SHEET. C INCLUDING
FRAMING DIMENSIONS )
36' CLEAR WIDE PATH LIF EGRESS
LEADING TO REQUIRED EXITS
T.S. DET.
DISPLAY
KITCHEN
DISPLAY
DISPLAY
AREA
3' CLR.
F.O.S.
_ar"./�".Jf ' 1�.1�"lrfMrrwr�lsl�.rr.a�'•
SUSPENDED
--\\LIGHT FIXTURE
T.S. DET.
EXIST'G COL.
EXISTING TENANT
SEPARATION WALL
TO REMAIN
1117 rral
T.S. DET.
PRODUCT
BROCHURES
T.S, DET,
+1
DISPLAY
AREA
T.S. DET.
DISPLAY
T.S. DET,
' 36' CLEAR WIDE PATH OF EGRESS I
�.� LEADING TO REQUIRED EXITS
T.S. DET.
DISPLAY
ENTRY
T.S. DET.
FINISH EXPOSED END OF WALL
W/ PAINTED GYP, WALLBOARD
2009 IBC MEANS OF EGRESS ILLUMINATION
1006.1 Illumination required.
The means of egress, including the exit discharge, shall be
illuminated at all times the building space served by the
mans of egress is occupied.
1006.2 Illumination level.
The means of egress illumination level shall not be Tess than
1 foot - candle at the walking surface.
1006.3 Illumination emergency power.
The power supply for means of egress illumination shall
normally be provided by the premises' electrical supply.
In the event of power supply failure, an emergency electrical
system shall automatically illuminate the following areas:
1. Aisles and unenclosed stairways of rooms that
require two or more means of egress.
2. Corridors, exit enclosures and exit passageways...
3. Exterior egress components...
4. Interior exit discharge elements...
5. Exterior landings...for exit discharge doorways...
2009 IBC MEANS OF EGRESS ILLUMINATION
1006.4 Performance of system. Emergency lighting
facilities shall be arranged to provide initial illumination that
is at least an average of 1 foot - candle and a minimum at
any point of 0.1 foot - candle measured along the path of
egress at floor level. Illumination levels shall be permitted to
decline to 0.6 foot - candle at the end of the emergency
lighting time duration. A maximum -to- minimum illumination
uniformity ration of 40 to 1 shall not be exceeded.
SECOND MEANS
LIF EGRESS
EXIT ONLY
C EXIST'G EXIT DOORS)
STORE -FRONT ALUM. & GLASS
10' F.F,
5
F.O,S.J,
F,F. AN
7
6' -4'
10'-8"
14' -4"
2IutI"'
Approved By
NEW 6" WIDE STEEL STUD PARTITION /WALLS W/ 5/8" GYPSUM
WALLBOARD BOTH SIDES. WALL HEIGHT 8 FT. ABOVE TOP OF FLOOR SLAB
EXISTING STEEL STUD INTERIOR STUD WALLS TO REMAIN
ELEMENTS LOCATED ABOVE PLANE OF FLOOR PLAN
( AREAS DESIGNATED ON FLOOR PLAN AS ° 36° WIDE PATH OF EGRESS LEADING TO
REQUIRED EXITS" SHALL REMAIN PERMANENTLY MARKED & CLEAR OF ANY OBSTRUCTIONS )
( DIMENSIONS AS SHOWN REQUIRE FIELD VERIFICATION DURING THE CONSTRUCTION PROCESS )
REMODELED FLOOR PLAN Scale: 1/4" = 1-q"
OCCUPANCY LOAD CALCULATIONS & NOTES:
OCCUPANCY CLASSIFICATION FROM IBC SECTION 308.1
( MERCANTILE GROUP M )
( GROSS LEASE AREA ) 2,103.77 SQ. FT.
( OCCUPANT LOAD ) 73 PER IBC TABLE 1004.1.1
BASEMENT AND GRADE FLOOR AREAS = 1 OCCUPA
PER EA. 30 SQ. FT. GROSS AREA = 73
( TOTAL EMPLOYEES ) 3
( TOTAL OCCUPANT LOAD ) 73 + 3 :. 76
( EXIT AISLE WIDTH ) 36 INCHES PER IBC SECTION 1017.2
REVIEWED FOR
CODE COMPLIANC
APPROVED
N APR 1A2ud
City of Tukwila
BUILDINr nhvIRI
( EXIT AISLE ILLUMINATION ) 1 FOOT CANDLE AT THE
WALKING SURFACE PER IBC SECTION 1006.2
N
GRANITE TRANSFORMATION RETAIL STORE
7100 FUN CENTER WAY — TUKWILA, WA
Date 1
Approved By
IRevioion Description
0
z
Job Number
2071
RECEIVF�
CITYOFTU IA
MAR 2 5 2011
PERMIT CENTER
3/25/2011
Sheet Number
A-2.2
Of
2" x 2' x 1/4" STEEL TS COIL.
LENGTH OF COL, SHALL BE A MIN.
OF 5' -O" FROM TOP OF STEEL
BASE PLATE TO TOP OF COL.
C STEEL TLS, BOT. PLATE, &
FRAMING STUDS & BASE TRACK
STEEL TS, BOT, PLATE, &
FRAMING STUDS & BASE TRACK
5/8 " GYP. WALLBOARD
< PAINTED SURFACE FINISH )
6" WIDE STEEL WALL
FRAMING STUDS SPACED
@ 16' ac.
UN- SUPPORTED END OF
8 FT, HIGH PARTITION
6' WIDE STEEL WALL
FRAMING STUDS SPACED
@ 16' O.C,
'1/4" TECH 5' SELF -
TAPPING SCREWS @ 24' O.C.
< FRAMING STUD TO T,S )
STEEL TS, BOT, PLATE, &
FRAMING STUDS & BASE TRACK
ISOMETRIC VIEW
( STEEL STUD TO T.S )
5' x 5" x 1/4' THICK
STEEL BASE PLATE
x 2' x 1/4' STEEL TS COL,
LENGTH OF COL. SHALL BE A MIN.
OF 5' -O" FROM TOP OF STEEL
BASE PLATE TO TOP OF COL.
BASE PLATE PLAN VIEW
5' x 5' x 1/4' THICK
STEEL BASE PLATE
EDGE OF 1/4" STEEL
BASE PLATE & FACE OF
BOTH STEEL TS COL, &
STEEL WALL FRAMING STUD
1'
MAX, DISTANCE FROM FACE
OF TS COL. TO UN- SUPPORTED
END OF PARTITION
Sit
1/4' MIN, FILLET WELD
( 3 ) SIDES OF TS COL.
TO BASE PLATE
1/2' x 3 1/2' "HILTI KWIK BOLT'
EXPANSION ANCHORS STEEL BASE
PLATE INTO EXIST'G CONC. FLOOR
SLAB < 4 EA. PER PLATE ) REFER
TO BASE PLATE PLAN VIEW FOR
EXPANSION ANCHOR LOCATIONS
- STEEL TS, BOT. PLATE, &
FRAMING STUDS & BASE TRACK
2' x 2' x 1/4' STEEL TS COL,
LENGTH OF COL. SHALL BE A MIN.
OF 5' -0' FROM TOP OF STEEL
BASE PLATE TO TOP OF COL.
PLAN VIEW (0 FLOOR LEVEL
6' WIDE STEEL WALL.
FRAMING STUDS SPACED
e 16' O.G.
'1/4' TECH 5' SELF
TAPPING SCREWS @ 24' MC.
< FRAMING STUD TO T.S )
TOP SURFACE OF
STL. BASE TRACK
/\/ee
2' x 2' x 1/4" STEEL TS COL.
LENGTH OF COL. SHALL BE A MINI
OF 5' -O' FROM TOP OF STEEL
BASE PLATE TO TOP OF COL.
1/4' MIN. FILLET WELD
( 3 ) SIDES or TS COL.
TO BASE PLATE
5" x 5' x 1/4" THICK
STEEL BASE PLATE
MOUNT PLATE OVER
WALL STUD BASE TRACK
VERTICAL SIDE OF
STL. BASE TRACK
EXISTINTG 4" THICK
CONC. FLOOR SLAB
1/2" x 3 1/2' 'HILTI KWIK BOLT'
EXPANSION ANCHORS STEEL BASE
PLATE INTO EXIST'G CONC, FLOOR
SLAB ( 4 EA, PER PLATE ) REFER
TO BASE PLATE PLAN VIEW FOR
EXPANSION ANCHOR LOCATIONS
ELEVATION /SECTION VIEW
STEEL STUD PARTITION WALL VERTICAL STIFFENER DETAILS
MISCELLANEOUS DETAILS
Scale 3 = 1-0"
REVIEWED FOR
CODE COMPLIANCE
APR
City of Tukwila
DUILDINIr nivicinhl
W
cr
0
Immo
w
cr
z
O
pa:
cc
O
LL
cr
Z
h
W
0
1•-
1
CC
w
u. z
w
z
0
Tog
0
Dote I
Approved By
c
0
:_
0..
0
g
m
0
c
0
•0
.,
tr
0
z
Job Number
2071
Lawrence M. Camp . - It
STATE OF WASHINGTQN
cilvoFnSLn
MAR 2 5 2011
PERMIT CENTER
3/26/2011
Sheet Number
A -5
Of