Loading...
HomeMy WebLinkAboutPermit D11-078 - GRANITE TRANSFORMATIONS - TENANT IMPROVEMENTGRANITE TRANSFORMATIONS 7100 FUN CENTER WY Dl 1 -078 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: htq,://www.ci.tulcwila.wa.us DEVELOPMENT PERMIT Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: Project Name: GRANITE TRANSFORMATIONS Permit Number: D11 -078 Issue Date: 04/18/2011 Permit Expires On: 10/15/2011 Owner: Name: H2 OFFICE LLC Address: 7100 FUN CENTER WAY STE 100 , TUKWILA WA 98188 Contact Person: Name: JOLEE CONVER Address: 20725 NE 38 ST , SAMMAMISH WA 98074 Contractor: Name: GRANITE TRANSFORMATIONS /KNG CO Address: 219 S HORTON , SEATTLE WA 98134 Contractor License No: GRANITK951KC Phone: 425 985 -9687 Phone: 206 - 217 -2500 Expiration Date: 08/09/2011 DESCRIPTION OF WORK: ADD NEW TENANT PARTITIONS/WALLS AND INSTALL 6 INCH HIGH DISPLAY PLATOFROM. NEW CARPET AND /OR TILE FLOORING IN SOME DISPLAY AREAS WITH THERE BEING NO CHANGES TO THE BUILDING STRUCTURE. Value of Construction: $5,500.00 Fees Collected: $338.46 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0019 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11-078 Printed: 04 -18 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: 1/4,) Private: Profit: N Private: Public: Non- Profit: N Public: Date: 4_4 gam' (, 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached (I r to this permit. Signature: Print Name: Date: f- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11-078 Printed: 04 -18 -2011 7: All construction shall be done in conform- with the approved plans and the requirem *of the International Building Code or International Residential , International Mechanical Code, Washingt to Energy Code. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with doc: IBC -7/10 D11-078 Printed: 04 -18 -2011 the principal strokes of the letters not less th 0.75 inch (19.1 mm) wide. The word "EXIT" s have letters having a width not less than 2 inches (51 mm) wide pt the letter "I ", and the minimum spacing een letters shall not be less than 0.375 inch (9.5 mm). Signs larger tha the minimum established in section 1011.5.1 the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (1FC 901.4) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance No. 2050). 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 39: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11-078 Printed: 04 -18 -2011 CITY OF TUKWIND Community Developilirnt Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www. ci. tkwila. wa. us Building Pernifo. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 7/ CO j:7jA/ CW'e WAX. King Co Assessor's Tax No.: 21i9----3)04- 1 (12_ Suite Number: 730 Floor: 4-M3O New Tenant: Yes ❑.. No Tenant Name: 4.R.40/ Y/r 724 sreyrnArlaisic Property Owners Name: N 2 OBE"/ a */ L L C IOa Mailing Address: 7&V 7t2,V 6j j// E u'/A/ S(J /yt TvkWIe.,c City WA I8/813 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: f0 LEE CON V ( Day Telephone: (.2) %95 9'687 Mailing Address: 20.72 Nt 3342. Sr; ,5'A.14/'1 1 /SI/ WA YX 7¢.. City E -Mail Address: 101-Ewe q T$6. 4 rTL 6 • con Fax Number: (2 J 2/ 7 25-0 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: / • L� 1 .1! 4d / ♦4 0 Mailing Address: e 0725. A/E 39//,, ST Cdr/ fi4M /SLy wA !/JO %f City State Zip Day Telephone: (t2 . 78C 9677 Fax Number: reo6) 2/ 7 250/ Expiration Date: ,4 /)c -,,. B, 20// Contact Person: COL .iOf yE,� E -Mail Address: TOL EEC C°TSEATT L,E I Can Contractor Registration Number: ('g4N /T1(? 37 KC ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: G Lj W,ee/I/'6 Ai; C ttAr eZ _ Mailing Address:Jj` // Sa v' /87)4. PLAGA- Contact Person: ZAWRcf/VCE E -Mail Address: 1.M CA RCN/ rTCT c COMC4 ST, NET" R &i V A/ WA ygo58 -7r/ City State Zip Day Telephone(4i75) 2 5j77� Fax Number: ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: State Zip E -Mail Address: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid _ ): $ c5-09 --^ Existin uilding Valuation: $ Scope of Work (please provide detailed information): FA Will there be new rack storage? ❑ ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11 " paper including quantities and Material Sa ety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Linet2010 Applications17 -2010 - Permit Application.doc Revised: 7-2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 98.77 2, / !� TYPE G V P.6 M / , rd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No if "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" .x 11 " paper including quantities and Material Sa ety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Linet2010 Applications17 -2010 - Permit Application.doc Revised: 7-2010 bh Page 2 of 6 PUBLIC WORKS PERMIT INFOOTION — 206 -433 -0179 1 Scope of Work (please provide detailed information): ,4 PO New TENANT- PA.T /TIoA/ W 4 J/ISTALLA -T /O V OF 6 hvoii HI Di5R4y P64TFo/W p 2 P644' Nt W s/ c,4'A y-E rSS•P4,eATC A Z/t1ITJ A/& IW CARA r /5JL Tike iA,/ S C� •_eiS,.S Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Tukwila ❑ ...Water District # 125 ❑... Highline .. Water Availability Provided ewer District .. Tukwila .. Sewer Use Certificate ❑ ...Valley View . El... Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance ❑... Easement(s) Proposed Activities (mark boxes that anoIv): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance El.. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut o .. Total cubic yards cubic yards ❑ .. Sanitary Side Sewer El.. Cap or Remove Utilities El.. Frontage Improvements El.. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size.. ❑ .. Temporary Water Meter Size . El.. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ El.. Water Main Extension Public ❑ ❑. ❑. ❑. ❑. ❑... Geotechnical Report 0... Maintenance Agreement(s) El.. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) El.. Hold Harmless — (ROW) El... Right-of-way Use - Profit for Tess than 72 hours ❑... Right -of -way Use — Potential Disturbance El... Work in Flood Zone ❑... Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line WO # WO # WO # Private ❑ Private ❑ El... Grease Interceptor ❑... Channelization ❑ ... Trench Excavation ❑... Utility Undergrounding ❑ .. Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water El.. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Fornu- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 3 of 6 MECHANICAL PERMIT INFORMATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INF RMATION ((xis rc s ySTFTn 7I M.R /N ANA- Al Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New.... ❑ Replacement.... ❑ Commercial: New.... ❑ Replacement.... ❑ Fuel Type: Electric ❑ Gas.... ❑ Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H: Applications1Forms- Applications On Line12010 Appiications17 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 4 of 6 PLUMBING AND GAS PIPING PER. INFORMATION — 206 - 431 -3670 • PLUMBING AND GAS PIPING CONTRACTOR INFORMATION fietker 6j«S'f/ v rt�i . pev/oof Company Name: PeiQMI7 -- 7r' /2&/4//1( eiNC ✓,4w'gez%) Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): f%f sI y,,c( y / ,eiF -yAi QUTLFT �7Z Occupancy (per Int'l Building Code): Al ri fene4vt/j7 Utility Purveyor: Water: / Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 5 of 6 PERMIT APPLICATION NOTES — Illicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: AUTHQRIZED AGENT: LTFoL e Cf)r) V Mailing Address: 2 O 771 Date: .-I 2S ),1 / Day Telephone: - �� 6B7 21%11 rvtQ1'n cS (Ai 4 9 )7� City State Zip IDate Application Accepted: Date Application Expires: Staff Initials: H:\ApplicationsTorms- Applications On Line12010 Applications1.7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 11110 410 wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us RECEIPT Parcel No.: 2423049092 Permit Number: D11 -078 Address: 7100 FUN CENTER WY TUKW Status: PENDING Suite No: Applied Date: 03/25/2011 Applicant: GRANITE TRANSFORMATIONS Issue Date: Receipt No.: R11 -00586 Initials: User ID: Payee: JEM 1165 Payment Amount: $338.46 Payment Date: 03/25/2011 04:02 PM Balance: $0.00 GRANITE TRANSFORMATIONS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1652 338.46 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $338.46 202.40 131.56 4.50 doc: Receiot -06 Printed: 03 -25 -2011 INS'ECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. • l-O7g CITY OF TUKWILA BUILDING DIV 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: t Type of Inspection: rp . Address( Date C�Flec� :/the ( Special Instructions: Date Wanted: ' /' ( a.m. Requester: Phon No: zs -Iss —5%0.3'7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: rf Art- (.4ktptap a8-14oxicA. g 1,) -`1 A IN- A .t.( Inspector: Date: • r7 REINSP N FEE REQUIRED Pri r to . next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. w INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It" 6300 Southcenter Blvd., #1'00, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line ('206) 431 -2451 DU- 0`1 Project: ,,,.,,,1/44,7,-c- 1 Y ,i.qJ Type f Inspecctio n: & , Address: 1 WO Date Called: Special Instructions: 0 S� 9 S- V r Date Wanted: S _r /a.m� p.m. Requester: -roto Phone No: / 475 -rh v -6/55 Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: Inspector: Date: • n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 600 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC IQN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.; #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Prroiect: r-'>S CI r v� l7,va,JbrJ i J Type of spection: i. Hr A,A•& , A_G, Address: ate Called: Special Instructions: p-4 3 Date Wanted: .4_ "2,6 — y a.m '''.rn. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: n r A{ p A-( 1 1 .,n .s-t ct. aAP t rak G P !k S 40 �r ear G,J Inspector: Date J REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid•at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �wae.,....a.,. :5...._A� _;n 'r- �l - INSPECTION NUMBER cn� 'xaY�• -e ..p . INSPECTION RECORD Retain a copy with permit /1 -4- -o3$ 0 -7C5 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: Ayl 4 3. 40 vt5 ,-wv'I c 0d T e of s pect : -Iii- Y\ +0 04 2—____ -- A 5 ( - Address: --7,a o 47./ ,jce, Suite #: /3v �s � eonta Perso Special Instructions / Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: } Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: — -JAL ok- r t C. N OL og- , / Needs Shift Inspection: } Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: S-- Date: 40s f/t Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • • �.r • • • • • ti .1 •r ,.9 .4 • • • IERMITC04RDCOPI1111 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -078 DATE: 03/25/11 PROJECT NAME: GRANITE TRANSFORMATIONS SITE ADDRESS: 7100 FUN CENTER WY, STE 130 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EPARTMENTS: Cl ding ivision Public Works Il e Prevention Structural Planning Division Permit Coordinator El DETERMINATION OF COMPLETENESS: (Tues., Thurs.) LY1 Complete Comments: Incomplete DUE DATE: 03/29/11 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04/26/11 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople P ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GRANITE TRANSFORMATIONS /KNG CO Phone 2062172500 Address 219 South Horton Suite /Apt. City Seattle State WA Zip 98134 County King Business Type Corporation Parent CONVER CORPORATION Company UBI No. 602464384 Status Active License No. GRANITK951KC License Type Construction Contractor Effective Date 8/9/2005 Expiration 8/9/2011 Date Suspend Date Specialty 1 Tile, Ceramic, Mosaic, Natural And Mfg Stone Specialty 2 Unused Other Associated Licenses License Name Type Vp Specialty 1 p y Specialty 2 Effective Date Expiration Date Status GRANIT *927DD GRANITE TRANSFORMATIONS /SPOKAN Construction Contractor Floor Covering And Counter Tops Unused 3/3/2008 3/5/2012 Active GRANITC962J3,TRANSFORMATIONS GRANITE /KG CTY Construction Contractor Resilient F /Counter M /Plastic Other (Specify) 5/4/2004 5/4/2006 Expired Business Owner Information Name Role Effective Date Expiration Date CONVER, ANTHONY President 05/03/2005 Bond Amount Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 AM STATES INS 6554925 10/21/2008 Until Cancelled $6,000.0010/27/2008 10/01/2010 2 AMERICAN STATES INS 6554925 03/31/2008 10/21/2008 $6,000.0010/07/2008 10/01/2010 1 CBIC SG2591 08/08/2005 Until Cancelled 10/02/2008 $6,000.0008/09/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 TRAVELERS INSURANCE CO 6804005R329 10/01/2010 10/01/2011 $1,000,000.00 10/01/2010 4 AMERICAN STATES INS CO 01CG9256612 10/01/2008 10/01/2011 $1,000,000.00 10/01/2010 3 AMERICAN STATES INS CO 01CG9256612 10/01/2007 10/01/2008 $1,000,000.0009 /26/2007 2 SAFECO AMERICAN STATES INS 01CG925661 2 10/15/2005 10/15/2008 $1,000,000.0009 /20/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 04/18/2011 • Property Line • • -`Jet oce • .•.". • �r 1 •aoe 1' PLANNiNG APPROVED • No changes .can be made to these plans without approval from the Planning Division of DCD Approved [Date: SEPARATE PERMIT REQUIRED FOR: iJ Machanlcal ladi Electrical f 'Plumbing GM Ptping City 0f as Tukwlta BUILDiNG DIVISION ... 2; 1:•' �• t•. ,j..• •s Z J•'U • hs all be ma.:7 to the scope �� :�zot�Driar approval of s!, a Burdiri IDivisian. may include will plan review tees. .L Property Line • s`b= Exist! Imo. • , Line of ordinary , high waters.-' /' 40' Offset from r' ordinary g ,./ water line 21' Light Pole ,I J r- ,, �, . G `ry Existing standard Drain to Sanitary Sews ,,1 21' Light Pole. 1 / Asphalt • ?' rty Line / with guredetom e plan. ML) New • striping sting Asphalt Light. standard `e ton 0.63 'NBW� Property Line r • •y Power easement Light9 standard •, • Existing Light standard ♦z 100' Offset from ordinary high water line 21' Light Pole r • 200' Offset from , ordinary high water line --•j' • Futur+eN sidewalk • X ht MN WS Property Line Landscape ``• -- • Buffer 21 ygh u Cen t er 'we> Light standard/ underground power, SITE PLAN for GRANITE TRANSFORMATIONS SCALE: 1° = 30' -0' TOTAL NUMBER OF PARKING SPACES REQUIRED FOR THIS TENANT SPACE IS SIX (6 ) ( BASED ON 2 1/2 SPACES PER EACH 1,000 SQUARE FEET OF GROSS AREA ) TOTAL NUMBER OF PARKING SPACES ASSIGNED TO THIS SPACE IS NINE (9) 441/4 VICINITY MAP nts BIDDER DESIGN SYSTEMS: DRAWING INDEX: t ELECTRICAL ( REQUIRES SEPARATE PERMIT ) 2. MECHANICAL ( HV &AC ) ( REQUIRES SEPARATE PERMIT ) 3. PLUMBING ( REQUIRES SEPARATE PERMIT ) 4. BUILDING SPRINKLER & FIRE ALARM SYSTEM ( REQUiFIES SEPARATE PERMIT ) ( BUILDING FIRE PROTECTION SYSTEM, INCLUDING BUT NOT UMITED TO AUTOMATIC BUILDING SPRINKLERS & FIRE ALARMS SHALL BE DESIGNED & INSTALLED PER 1.0.0. CHAPTER 9 IF EXISTING SYSTEM 18 MODIFIED). 6. ALL SUPPLIERS OF PRE - MANUFACTURED EQUIPMENT SHALL PROVIDE SPECiFtCATIONEQUIPMENT OPERATION INFORMATION TO THE TENANT PRIOR TO INSTALLATION OF SAID EQUIPMENT, & SHALL ALSO PROVIDE SCHEDULED MAINTENANCE & WARRANTY INFORMATION WHERE APPROPRIATE. 8. INSTALLATION OF BUILDING SIGNS ( REQUIRES SEPARATE PERMIT ) ARCHITECTURAL. DRAWINGS A -1.0 COVER SHEET, SITE PLAN, VICINITY MAP, DRAWING INDEX, LEGAL DESCRIPTION, ETC. A -2.01 (OVERALL BUILDING FLOOR PLAN ( NO REVISIONS TO EXTERIOR WALLS ) A -2.2 'REMODELED FLOOR PLAN ( TENANT IMPROVEMENTS ) A-5 MISCELLANEOUS DETAILS CODE REFERENCES & BUILDING STATISTICS I. OCCUPANCY GROUP: M ( MERCANTILE ) PER i.B.C. SECTION 309 2. EXIST'G BLDG CONSTRUCTION CLASSIFICATION TYPE V-B ( SPRINKLERED PER I.B.C. SECTION 3. APPLICABLE CODES: ( CURRENT EDITION OF ALL OF THE FOLLOWING ) AMERICAN NATIONAL STANDARD ( ICC /ANSI M17.1 -2003 ) INTERNATIONAL BUILDING CODE ( 2009 EDITION ) WASHINGTON STATE BUILDING CODE ( 2009 EDITION ) CHAPTER 61-60 WAC INTERNATIONAL MECHANICAL CODE ( 2009 EDITION ) INTERNATIONAL FIRE CODE (2009 EDITION ) UNIFORM PLUMBING CODE ( 2009 EDITION ) WASHINGTON STATE ENERGY CODE ( 2000 EDITIOP4 ) CHAPTER 61 -11 WAC WASHINGTON STATE INDOOR AIR QUALITY CODE ( 2009 EDITION .) NATIONAL ELECTRICAL CODE ( CURRENT EDITION ) EACH OF THE RELATED STANDARDS & STATE AMENDMENTS TO THE GODES USTED ABOVE ( LATEST EDITIONS CITY OF TUKWILA MUNICIPAL CODE COVER SHEET NOTES ( GROSS LEASE AREA )2,198.11 SO. FT. PROJECT DESCRIPTION: 602.6 & TABLE 831 ) THE GRANITE TRANSFORMATION SPACE IS TO BE USED AS A DISPLAY /RETAIL OUTLET STORE FOR GRANITE COUNTER- TOPS, BATHING TUB & SHOWER COMPARTMENT SURROUNDS, & 18 OPEN TO THE PUBLIC EITHER BY APPOINTMENT OR BY DROP -IN RETAIL SHOPPERS. THERE WILL BE A SMALL STAFF OF EMPLOYEES IN THE STORE TO PROVIDE ADVICE ON THE USE OF THE GRANITE PRODUCTS, AS WELL AS TO PROVIDE THE CUSTOMER WITH COMPETITIVE PRICE BIDS FOR COMPARATIVE SHOPPING. THE PRODUCTS ARE INTENDED FOR UBE PRIMARILY IN THE RESIDENTIAL MARKET FOR EITHER NEW OR REMODELED PROJECTS. THE PRODUCT 13 STORED, SHIPPED & INSTALLED BY CREWS FROM A SEPARATE OFF -SITE LOCATION. THIS FACILITY. IS PRIMARILY A SHOWROOM FOR THE PRODUCTS. REFER TO THE SCOPE OF WORK STATEMENT ON THE RE- MODELED FLOOR PLAN DRAWING ON SHEET A -2.2 FOR ADDITIONAL INFORMATION ON THE WORK. LEGAL DESCRIPTION: (AS SHOWN ON SURVEY BY CENTRE POINTE SURVEYING DATED 5/6/03) THAT PORTION OF THE WEST HALF OF SECTION 24, TOWNSHIP 23. NOR. F H O7�MERIDIAN, KING COUNTY WS N EAST M 4 AAK I I U Yo t UiW QL ;: COMMENCING AT THE INTERSECTION OF 711E 2M-LINE OF PRIMARY *STATE HIGHWAY NO. :4 GREEN RIVER iN1'ERCHANG ALL AS CONVEYED TO' OR 'CONDEMNED BY 114E STATE OF WASHINGTON BY DEEDS RECORDED UNDER KING COUNTY RECORDING NOS. 5499612. 5507291 5510773. 5503778, ' 5536582. AND S UNDER XiNG COUNT SUPr:R10R COURT USE NO. 588089. STA POC (2M 134+28.58. WITH THE A-LINE STA POT A 102+82.2 AS SHOWN ON THAT CERTAIN MAP ON FILE WrTH THE STA OF WASHINGTON DEPARTMENT OF TRANSPORTATION LABELED SR 405 GREEN • RIVER INTERCHANGE R1GWr OF WAY STA 99+00 TO • STA 120+00. SHEET 2 OF 2, APPROVAL DATE OF JANUARY 30, 1962, WITH LAST REVISION DATE • OF DECEMBER 31, 1992 THLICE NORM 42'30'02" EAST ALONG THE CENTERLINE OF SAID ALINE, 80.55 FEET TO STA 103+70.67 OF SAID A-UNE: THENCE NORTH 4729'5588'"" WEST. 60.00 FEET TO A POINT ON THE NORTHERLY RIGHT OF WAY SAID PRIMARY STATE HIGHWAY NO. 1 • SAID POINT. BEING THE BEGINNING OF A CURVE .CONCAVE TO THE SOUTH WITH A RADIUS OF 183.00 FEET. AND ALSO BEING THE TRUE POINT OF BEGINNING: THENCE NORTHERLY.. EASTERLY AND SOUTHERLY ALONG SAID RiCHT OF WAY ON THE ARC OF SAID CURVE THROUGH A CENTRAL ANGLE OF 64'48'29" A DISTANCE OF 184.37 FEET; THENCE LEAVING SAID RIGHT OF WAY, AND BEARING NORTH 2114'11" EAST, 38.16 FEET: ' THENCE NORTH 84'411'08" V ST, 5.90 FEET; 'HENCE NORTH 22`51 18' WEST, 166.10 F1 ET: ORDINARY HIGH WATER UNE OF THE FEET PONT R. ON AS ITEWAS • MAPPED BY' BARGHAUSEN CONSULiING ENGIN S INC. ON AUGUST 11. 1997;• THENCE FOLLOWINGQCOURSES AND DISTANC> , WATER LJNE bF SAID RIVER THE SOUTH 70'00100.73`00F00" - , 39.06 FEET; 65.00 .FEET THE ICE SSOOUTTH H 6700 0" WEST i� 100.00 FEET; • • THENCE SOUTH 5740eOD" W 30.08 FEET; THENCE SOUTH 65'50'00' IiVFST. 3300 FEET: THEE SOUTH 5630'CD" WEST. 100.00 FEET; THENCE SOUTH 51'00'00" WEST. 50.00 FEET THENCE SOUTH 35'40'00" VEST. 40.00 Fe* THEME sotrnr S9'GO'QO" WEST. 80000 F€E7; - THENCE SOUTH 52•0'00" '11r5T. 50.00 FEET TO THE NORTHEASTERLY RIGHT OF WAY FOR SAID 2M -UNi~ THENCE SOUTHERLY ALONG SAID RIGHT OF WAY UNE TO ITS INTERSECTION 1'ti411.I THE NORTHERLY RIGHT OF WAY OF SAiD A--UN THENCE NORTH 4230'02 EAST ALONG SAiD NORTHERLY RIGHT OF WAY. L42 FEET 7D THE POINT GF• BEGINNING. T • G KNOWN AS adjtated Parcel 1 of Boundary LSne Ad Mmertt No. recorded under Recording No. B9D6309017). SITUATE In the County. of. King. State of Washington. FILE COPY Permft No. PI>'n review approval is subject to errors and omissions. A p; roml of construction documents does not authorize VI( Violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: City Of T1bkwita BUILDING DIVISION - REVIEWED FOR ODE COMPLIANCE Ipp OVED • APR 14 2uii City of Tukwila BUILDING nivirInni RECEIV CINOFTU LA MAR 2 5 2011 PERMIT CENTER W cc O Fon co J F W cr Z O Pas scc Oung co cr: Z GRANITE TUKWILA, WA 7100 FUN CENTER WAY -a 2 Approved By s c 0 t Q 0 i f z JUE3 NUM5ER'.: 2071 DRAWING DATE 3/25/2011 COVER SHEET for GRANITE TRANSFORMATIONS I00' 10' 24' -2' 25' 25' 24' -2' 10' 1' -8 1/4' 7' -4 1/4' $'--11 7/8' 1' -4' 31' --11 5/8' 9' 16' -8' 16' -8' 5' -4' MECHANIICAL & ELECTRICAL SPACE J 0 COL. SUBWAY SANDWICH SHOP 9, iet co a SUNRISE DENTAL_ DENTAL CIiNIG) i 10' 24'_2' COL EXIST'G COL, BAJIO MEXICAN GRILL ( RESTAURANT ) WALL EXISTING TENANT i— SEPARATION WALL TO REMAIN Co Co -J -J EXISTING TENANT SEPARATION WALL TO REMAIN EXIST'G COL; EXISTING TENANT SEPARATION WALL TO REMAIN VACANT SPACE EXISTING TOILET ROOM INSTALLED UNDER PREVIOUS PERMIT TO REMAIN EXISTING EXTERIOR WALLS, DOORS, & WINDOWS TO REMAIN INSTALLED UNDER PREVIOUS PERMIT ---"� Nj 0 EXIST'G TO REMAIN 10' x 10' SECTIONAL HI -LIFT ALUM. & GLASS DOOR a '0 0 w EXTENT OF TENANT IMPROVEMENT LEASE AREA EXISTING EXTERIOR WALLS, DOORS, & WINDOWS TO REMAIN INSTALLED UNDER PREVIOUS PERMIT 9 is • z Cr Cu N 18' -8' 6'-4' 100' 10' 10` -8' _ } 14' -4' IS- 24, ^2' 10' 0 '-, OVERALL BUILDING FLOOR PLAN ( NO REVISIONS TO EXTERIOR WALLS ) scale 1/8" = 1' -0" NOTICE TO ALL PERSONS PERFORMING WORK ON THIS PR QJECT PRIOR TO THE COMMENCEMENT OF ANY AND ALL WORK ON THIS PROJECT, IT SHALL BE THE RESPONSIBILITY OF ALL PERSONS PERFORMING WORK ON OR SUPPLYING MATERIALS TO THIS PROJECT TO COMPLETELY FAMILIARIZE THEMSELVES WITH ALL CODES AND ORDINANCES PERTAINING TO THAT PORTION OF THE PROJECT WHICH THEY ARE TO PERFORM WORK OR SUPPLY MATERIALS. SAID WORK OR SUPPLY OF MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. IF ANY PORTION OF THE DRAWINGS, NOTES, OR SPECIFICATIONS ARE NOT IN CONFORMANCE WITH SAID APPLICABLE CODES AND ORDINANCES, IT SHALL BE THE RESPONSIBILITY OF EACH AND EVERY PERSON PERFORMING WORK ON, OR SUPPLYING MATERIALS TO THAT NON- CONFORMING PORTION OF THE PROJECT TO IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF THE DISCREPANCY BETWEEN THE DRAWINGS AND APPLICABLE CODES AND ORDINANCES. IT SHALL THEN BE THE RESPONSIBILITY OF THE ARCHITECT TO IMMEDIATELY MAKE CORRECTIONS TO THE DRAWINGS AS REQUIRED TO BRING DRAWINGS INTO CONFORMITY WITH SAID CODES AND ORDINANCES. THE ARCHITECTS CORRECTIONS SHALL BE MADE WITH EXPEDIENCY SO THAT THE WORK OF OTHERS CAN PROCEED WITH THE LEAST INTERRUPTION TO THE PROJECT. IT SHALL BE THE RESPONSIBILITY OF ANY PERSONS OR SUB - CONTRACTORS PERFORMING WORK ON, OR SUPPLYING EQUIPMENT OR MATERIAL ( HEREINAFTER REFERRED TO AS WORK ) TO THIS PROJECT UNDER A SEPARATE AGREEMENT OR CONTRACT WITH THE OWNER TO COMPLY WITH ALL CODES AND ORDINANCES THAT EFFECT THE OWNERS INTENDED USE OF THE PROJECT. W THE PERFORMANCE OF SAID WORK SHALL REQUIRE ALTERATION OR MODIFICATION OF THE PROJECT, THEN SAID WORK SHALL NOT BE PERFORMED WITHOUT FIRST HAVING THE OWNER'S WRITTEN AUTHORIZATION TO PROCEED, AND THIS AFTER FULLY DISCLOSING TO THE OWNER WHAT FINANCIAL AND OTHER OBLIGATIONS SHALL BE REQUIRED OF THE OWNER AS A RESULT OF SAID WORK. WHERE EXISTING CONSTRUCTION OR CONDITIONS ARE IN PLACE ON PROJECT SITE OR ON PREMISE IN ANY MANNER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY LOCATION, TYPE OF CONSTRUCTION, AND ANY OTHER CONDITIONS THAT WILL HAVE AN EFFECT ON THE NEW CONSTRUCTION AS TO ITS LOCATION, SIZE, CLEARANCE. STRUCTURAL INTEGRITY, ETC.. ANY DIS- CREPANCIES FROM WHAT IS SHOWN ON THE DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING SO THAT HE MAY INVESTIGATE SAID DISCREPANCIES, AND MAKE CORRECTIONS TO THE DRAWINGS AS MAY BE REQUIRED, OR TO MAKE OTHER REMEDIES AS REQUIRED. II -o1� 2,198.77 SQ. FT. C GROSS LEASE AREA ) SCOPE OF WORK STATEMENT: REVIEWED FOR CODE COMPLIANCE APR 14 2011 City of Tukwila BUILDING fIVISIOM 1. ACCESSIBLE TOILET ROOM IS EXISTING UNDER PREVIOUS PERMIT 2. FURRING ON INTERIOR SIDE OF EXTERIOR WALLS TO CONCEAL- COLUMNS, WALL BRACING, & OTHER EXPOSED STRUCTURAL COMPONENTS & HARDWARE tom► EXISTING UNDER PREVIOUS PERMIT ALL EXISTING EXTERIOR WALL .CONSTRUCTION TO REMAIN UNCHANGED 8' . 24' 16' 48' TRANSFORMATION RETAIL STORE GRANITE 71.00 FUN CENTER WAY - TUKWILA, WA Date Approved By c 0 0 N m 0 c 0 'o 0 ce 0 z Job Number 2071 OMBRA OF TIJ LA MAR 2 5 2011 PERMIT CENTER 3/26/2011 Sheet Number A -2.01 Of SCOPE OF WORK STATEMENT: 1. ADD TENANT PARTITION WALLS PER PLAN 2. ACCESSIBLE TOILET ROOM IS EXISTING UNDER PREVIOUS PERMIT 3. FURRING ON INTERIOR SIDE OF EXTERIOR WALLS TO CONCEAL COLUMNS, WALL BRACING, & OTHER EXPOSED STRUCTURAL COMPONENTS & HARDWARE IS EXISTING UNDER PREVIOUS PERMIT 4. ALL EXISTING EXTERIOR WALL CONSTRUCTION TO REMAIN UNCHANGED 5. ELECTRICAL & MECHANICAL SYSTEM MODIFICATIONS SHALL BE INSTALLED BY SEPARATE PERMITS. ( INCLUDING LIGHTING REVISIONS ) 6. ALL SIGNAGE ( ON BUILDING OR SITE ) SHALL BE INSTALLED BY SEPARATE PERMITS.THIS INCLUDES A- BOARDS, STICK SIGNS, FLAGS, ETC. 7.. INSTALLATION OF 6 INCH HIGH DISPLAY KITCHEN PLATFORM 8. ALL TENANT SEPARATION WALLS ARE EXISTING AND WERE INSTALLED UNDER PREVIOUS PERMIT. EXISTING TOILET ROOM WALL 23/32 T &G PLYWOOD SUB -FLOOR OVER. RAISED PLATFORM - FRAMED W/ PRESSURE TREATED 2x4 SLEEPERS ON EDGE @ 16' Q.C. PRESSURE TREATED 2x4 SLEEPERS ON EDGE PERIMETER FRAMING EXIST'G COL. 6 _ 9' -1 5/8' 11' -11 1/2" 15' --10 3/8' RAISED PLATFORM FRAMING PLAN Scale: 1/4` � 1' -04 NEW 6* WIDE STEEL FRAMING STUD NOTE: THE TOP OF ALL NEW STEEL STUD WALLS SHALL BE FRAMED TO A HEIGHT OF 8'-0" ABOVE TOP OF EXISTING FLOOR SLAB UNLESS NOTED OTHERWISE. DRAWING LEGEND: T.S. DET.- --5 E.Lb LOCATION OF VERTICAL TUBE STEEL PARTITION /WALL STIFFENERS REFER TO SHEET A-6 FOR DETAILS. EXIT PATHWAY LIGHTING FIXTURES MOUNTING HEIGHT 8' -10" ABOVE FIN. FLOOR LIGHTS ARE EXIST') IN LOCATIONS SHOWN ON FLOOR PLAN EXISTING STRUCTURAL FRAMING GRID LINE 36' CLEAR WIDE PATH OF EGRESS LEADING TO REQUIRED EXITS F.O.s. ----- DIMESIONED TO FACE OF STUD 1 DIMESIONED TO FINISH FACE OF WALL C. COL, Co COL. EXIST'G COL. (NOTAPART) NOT A PART ) C. WALL 12'-8 1/8' 6' EXISTING TENANT SEPARATION WALL TO REMAIN F.O.S. I3'-1 1/4" F.O.S. EXIST'G WALL EXISTING ELEC, PNL. F.O.S. EXISTING COL. t EXIST'G ) W.C. SEATING AREA IDEA CENTER BUSINESS OFFICE C EXIST'G ) 19x17 LAV. C EXIST'G > LEVER HARDWARE BOTH SIDES OF DOOR EXIST'G WALL EXISTING TENANT SEPARATION WALL TO REMAIN C. EXISTING PLUMBING cc LL O z e.d FRAMED HEADER OVER 3'--1 3/4' 4' F.O.S. fir rig .��rr.�.�.rrrrrrrrrFf.��'.�.ft' T.S. DET, 3°x 7° CASED IUPN'G, 6' -0 3/16" 3'--6" F.O.S. RAISED PLATFORM - FRAMED W/ PRESSURE TREATED 2x4 SLEEPERS ON EDGE W/ 23/32 T &G PLYWOOD SUB -FLOOR OVER. ENGINEERED WOOD FIN. FLOORING OVER. REFER TO PLATFORM FRAMING DETAIL ON THIS SHEET. C INCLUDING FRAMING DIMENSIONS ) 36' CLEAR WIDE PATH LIF EGRESS LEADING TO REQUIRED EXITS T.S. DET. DISPLAY KITCHEN DISPLAY DISPLAY AREA 3' CLR. F.O.S. _ar"./�".Jf ' 1�.1�"lrfMrrwr�lsl�.rr.a�'• SUSPENDED --\\LIGHT FIXTURE T.S. DET. EXIST'G COL. EXISTING TENANT SEPARATION WALL TO REMAIN 1117 rral T.S. DET. PRODUCT BROCHURES T.S, DET, +1 DISPLAY AREA T.S. DET. DISPLAY T.S. DET, ' 36' CLEAR WIDE PATH OF EGRESS I �.� LEADING TO REQUIRED EXITS T.S. DET. DISPLAY ENTRY T.S. DET. FINISH EXPOSED END OF WALL W/ PAINTED GYP, WALLBOARD 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the mans of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be Tess than 1 foot - candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... 2009 IBC MEANS OF EGRESS ILLUMINATION 1006.4 Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot - candle and a minimum at any point of 0.1 foot - candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ration of 40 to 1 shall not be exceeded. SECOND MEANS LIF EGRESS EXIT ONLY C EXIST'G EXIT DOORS) STORE -FRONT ALUM. & GLASS 10' F.F, 5 F.O,S.J, F,F. AN 7 6' -4' 10'-8" 14' -4" 2IutI"' Approved By NEW 6" WIDE STEEL STUD PARTITION /WALLS W/ 5/8" GYPSUM WALLBOARD BOTH SIDES. WALL HEIGHT 8 FT. ABOVE TOP OF FLOOR SLAB EXISTING STEEL STUD INTERIOR STUD WALLS TO REMAIN ELEMENTS LOCATED ABOVE PLANE OF FLOOR PLAN ( AREAS DESIGNATED ON FLOOR PLAN AS ° 36° WIDE PATH OF EGRESS LEADING TO REQUIRED EXITS" SHALL REMAIN PERMANENTLY MARKED & CLEAR OF ANY OBSTRUCTIONS ) ( DIMENSIONS AS SHOWN REQUIRE FIELD VERIFICATION DURING THE CONSTRUCTION PROCESS ) REMODELED FLOOR PLAN Scale: 1/4" = 1-q" OCCUPANCY LOAD CALCULATIONS & NOTES: OCCUPANCY CLASSIFICATION FROM IBC SECTION 308.1 ( MERCANTILE GROUP M ) ( GROSS LEASE AREA ) 2,103.77 SQ. FT. ( OCCUPANT LOAD ) 73 PER IBC TABLE 1004.1.1 BASEMENT AND GRADE FLOOR AREAS = 1 OCCUPA PER EA. 30 SQ. FT. GROSS AREA = 73 ( TOTAL EMPLOYEES ) 3 ( TOTAL OCCUPANT LOAD ) 73 + 3 :. 76 ( EXIT AISLE WIDTH ) 36 INCHES PER IBC SECTION 1017.2 REVIEWED FOR CODE COMPLIANC APPROVED N APR 1A2ud City of Tukwila BUILDINr nhvIRI ( EXIT AISLE ILLUMINATION ) 1 FOOT CANDLE AT THE WALKING SURFACE PER IBC SECTION 1006.2 N GRANITE TRANSFORMATION RETAIL STORE 7100 FUN CENTER WAY — TUKWILA, WA Date 1 Approved By IRevioion Description 0 z Job Number 2071 RECEIVF� CITYOFTU IA MAR 2 5 2011 PERMIT CENTER 3/25/2011 Sheet Number A-2.2 Of 2" x 2' x 1/4" STEEL TS COIL. LENGTH OF COL, SHALL BE A MIN. OF 5' -O" FROM TOP OF STEEL BASE PLATE TO TOP OF COL. C STEEL TLS, BOT. PLATE, & FRAMING STUDS & BASE TRACK STEEL TS, BOT, PLATE, & FRAMING STUDS & BASE TRACK 5/8 " GYP. WALLBOARD < PAINTED SURFACE FINISH ) 6" WIDE STEEL WALL FRAMING STUDS SPACED @ 16' ac. UN- SUPPORTED END OF 8 FT, HIGH PARTITION 6' WIDE STEEL WALL FRAMING STUDS SPACED @ 16' O.C, '1/4" TECH 5' SELF - TAPPING SCREWS @ 24' O.C. < FRAMING STUD TO T,S ) STEEL TS, BOT, PLATE, & FRAMING STUDS & BASE TRACK ISOMETRIC VIEW ( STEEL STUD TO T.S ) 5' x 5" x 1/4' THICK STEEL BASE PLATE x 2' x 1/4' STEEL TS COL, LENGTH OF COL. SHALL BE A MIN. OF 5' -O" FROM TOP OF STEEL BASE PLATE TO TOP OF COL. BASE PLATE PLAN VIEW 5' x 5' x 1/4' THICK STEEL BASE PLATE EDGE OF 1/4" STEEL BASE PLATE & FACE OF BOTH STEEL TS COL, & STEEL WALL FRAMING STUD 1' MAX, DISTANCE FROM FACE OF TS COL. TO UN- SUPPORTED END OF PARTITION Sit 1/4' MIN, FILLET WELD ( 3 ) SIDES OF TS COL. TO BASE PLATE 1/2' x 3 1/2' "HILTI KWIK BOLT' EXPANSION ANCHORS STEEL BASE PLATE INTO EXIST'G CONC. FLOOR SLAB < 4 EA. PER PLATE ) REFER TO BASE PLATE PLAN VIEW FOR EXPANSION ANCHOR LOCATIONS - STEEL TS, BOT. PLATE, & FRAMING STUDS & BASE TRACK 2' x 2' x 1/4' STEEL TS COL, LENGTH OF COL. SHALL BE A MIN. OF 5' -0' FROM TOP OF STEEL BASE PLATE TO TOP OF COL. PLAN VIEW (0 FLOOR LEVEL 6' WIDE STEEL WALL. FRAMING STUDS SPACED e 16' O.G. '1/4' TECH 5' SELF TAPPING SCREWS @ 24' MC. < FRAMING STUD TO T.S ) TOP SURFACE OF STL. BASE TRACK /\/ee 2' x 2' x 1/4" STEEL TS COL. LENGTH OF COL. SHALL BE A MINI OF 5' -O' FROM TOP OF STEEL BASE PLATE TO TOP OF COL. 1/4' MIN. FILLET WELD ( 3 ) SIDES or TS COL. TO BASE PLATE 5" x 5' x 1/4" THICK STEEL BASE PLATE MOUNT PLATE OVER WALL STUD BASE TRACK VERTICAL SIDE OF STL. BASE TRACK EXISTINTG 4" THICK CONC. FLOOR SLAB 1/2" x 3 1/2' 'HILTI KWIK BOLT' EXPANSION ANCHORS STEEL BASE PLATE INTO EXIST'G CONC, FLOOR SLAB ( 4 EA, PER PLATE ) REFER TO BASE PLATE PLAN VIEW FOR EXPANSION ANCHOR LOCATIONS ELEVATION /SECTION VIEW STEEL STUD PARTITION WALL VERTICAL STIFFENER DETAILS MISCELLANEOUS DETAILS Scale 3 = 1-0" REVIEWED FOR CODE COMPLIANCE APR City of Tukwila DUILDINIr nivicinhl W cr 0 Immo w cr z O pa: cc O LL cr Z h W 0 1•- 1 CC w u. z w z 0 Tog 0 Dote I Approved By c 0 :_ 0.. 0 g m 0 c 0 •0 ., tr 0 z Job Number 2071 Lawrence M. Camp . - It STATE OF WASHINGTQN cilvoFnSLn MAR 2 5 2011 PERMIT CENTER 3/26/2011 Sheet Number A -5 Of