HomeMy WebLinkAboutPermit D11-081 - ADAME RESIDENCE - ADDITIONADAME RESIDENCE
4629 S 160 ST
D11 -081
City oftrukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 5379800170
Address: 4629 S 160 ST TUKW
Suite No:
Project Name: ADAME RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -081
Issue Date: 05/03/2011
Permit Expires On: 10/30/2011
Owner:
Name: ADAME DENKEY B
Address: 4629 S 160TH ST , TUKWILA WA 98188
Contact Person:
Name: DENKEY ADAME
Address: 4629 S 160 ST , TUKWILA WA 98188
Phone: 206 - 817 -6765
Contractor:
Name: OWNER AFFIDAVIT ON FILE Phone:
Address:
Contractor License No: Expiration Date:
DESCRIPTION OF WORK:
STORAGE ROOM ADDITION UNDER THE EXISTING CARPORT PER ATTACHED DRAWINGS
Value of Construction: $3,436.80 Fees Collected: $439.63
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 26
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D11-081 Printed: 05 -03 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
Start Time:
End Time:
Fill 0 c.y.
End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter:
Permit Center Authorized Signature:
N
Date: 0503/(/
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature:
Print Name:
Date: 3/3 [Li_
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: * * *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
doc: IBC -7/10
D11-081 Printed: 05 -03 -2011
shall not be valid. The issuance of a permit b d on construction documents and other data 1 not prevent the
Building Official from requiring the correcti P errors in the construction documents and o data.
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All wood to remain in placed concrete shall be treated wood.
doc: IBC -7/10
D11 -081 Printed: 05 -03 -2011
CITY OF TUKW
Community Devel�ent Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /www. ci. tkwila. wa. us
fvaw\nr bpi 1
Building PerriNo. DI i --Q
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.:
.Site Address: li 62.9 '0041 16 Off'` { Y e e t Suite Number: Floor:
Tenant Name: 1- New Tenant: ❑ Yes ❑ .. No
T
Property Owners Name: De— .e. icy A 010...on C.
Mailing Address: At 6 aq (3 ,..)-Nn I a044'. ---A, ' l v k -AOk
City
53 C o O 4o -01
wA
State
`(818
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: �� -t1`C el A AOIMC� r i
Mailing Address: 246 9 �o%. 4 16041 S� " kw, `c,. LJ A qS tR%
City State Zip
E -Mail Address: Fax Number:
Day Telephone: (2-06) g r+- G 6,6"--
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number:
State
Zip
Expiration Date:
ARCHITECT OF RECORD — All plans must be stamped by Architect of Record
Company Name:
Mailing Address:
city
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
City
Day Telephone:
Fax Number:
Contact Person:
E -Mail Address:
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORMATION — 206 - 431 -3670
w&aluatioti,of Project ( ‘ � 0 l.) Existing lding Valuation: $
'Scope,of:WWotk (please provide detailed information): c-V l q ' 4 OOor, rk.A c(; 4 ;(:),A
4k _ �x:��:�•� car yo tvcL 61-1-
J
Will there be new rack storage? ❑ ....Yes
❑ ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
1f `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: V+pplications\Forms-Applications On Line12010 Applications17 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1st Floor
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
1f `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H: V+pplications\Forms-Applications On Line12010 Applications17 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 2 of 6
PLUMBING AND GAS PIPING PEW INFORMATION — 206 -431 -3670
•
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
city
Day Telephone:
Fax Number:
State Zip
Expiration Date:
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'1 Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 5 of 6
PERMIT APPLICATION NOTES —.cable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT: (30111
.ignature: �� /7— Date:
LilingAddress: 6Z nt Name: � €-'y oio.Me— Day Telephone: (Z-06) 8q-6T65—
� ��rsv' n �F(� "u^ � ' �y�C : �0. \,f1 l S tggj
City
IDate Application Accepted:
State Zip
Date Application Expires: 9
Staff Initials:
H 1Applications\Forms- Applications On Line\2010 Applications17 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 6 of 6
• •
r w City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 5379800170
Address: 4629 S 160 ST TUKW
Suite No:
Applicant: ADAME RESIDENCE
RECEIPT
Permit Number: D11 -081
Status: PENDING
Applied Date: 03/31/2011
Issue Date:
Receipt No.: R11 -00634
Payment Amount: $439.63
Initials: WER Payment Date: 03/31/2011 02:39 PM
User ID: 1655 Balance: $0.00
Payee: DENKEY ADAME
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1933 439.63
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $439.63
328.40
106.73
4.50
doc: Receiot -06 Printed: 03 -31 -2011
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. . PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION l!
6300 Southcenter Blvd., #100, Tukwila. WA 98188 • (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
.,11 -DEf1
q°3
Project: �I�
A-0 /� ill
�i `
�L l
Type of nspection:
f-t AJA1
1
a `.! :1 ICJ 0 '1.
Address:
4(,7 5- I / cotl sr
Date Called:
_
Special Instructions:
A " (
rila_
y -4`
anted:
Date Wanted:
------
c...1..m.
Requester:
Phone No:
G
- (7 6-
Approved per applicable codes. Corrections required prior to approval.
COMMENTS: f v A4 I 7-1-0 it.W
114 s (40 3 f S[ e. )
1
A--G .S qk eA. r-
v.)-ek r sr-AY /1-¢
t
n
/vv pJe ..e•41 (.
A/3.Ar
0 t AA / e-1 fin U AA 4-e,1
.
(UAltJ( iJ J---Q'
pv1-4,~
A 1 C
•
•
•
• •;IPr
.ii
N•
•
•
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule.reinspection.
� :a
.....7 ,::77. ....>7. s -.:(4: . —.-e y: s.:..r,-.7...ww±"rF..n ..-.. «. ......w.. - -. v :i�ar..,w.v. . .- r..t.i....
INSPECTION RECORD
' ~\ Retain a copy with permit
INSPECTIO NO. ' PERMIT NO. /
CITY OF TUKWILA BUILDING DIVISION C.--
6300 Southcenter Blvd., #100, Tukwila. WA 98188 x(206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pro' ct:
Plt.A me- Re.S` lit A
Type.Qf Inspection:
KC Ako vE Sr° t4Vv.
Addrgssii �� / .
Iee,Q sr
Date Called:
Special Instructions:
2 Cl lD � � � �
`ID "7 to
/
Date Wanted:
�
//
�� — i,
/"�a.m.
p.m.
Requester:
Phone No:
IZS
Approved per applicable codes. a Corrections required prior to approval. !
COMMENTS:
Inspttor:
OLAA X 111:2, j
Date:
,,4= i
r7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
•
City of Tukwila
Jim Haggerton, Mayor
De p artment of Community Development Jack Pace, Director
April 6, 2011
Denkey Adame
4629 S 160 St
Tukwila, WA 98188
RE: Incomplete Letter #1
Development Permit Application D11 -081
Adame Residence — 4629 S 160 St
Dear Ms. Adame,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
March 31, 2011 is determined to be incomplete. Before your application can continue the plan review
process the attached /following items from the following department(s) need(s) to be addressed:
Planning Department: Jaimie Reavis at 206 431 -3659 if you have any questions concerning
the attached comments.
Please address the comment above in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that four (4) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will
not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely, n n
L-C
Bill Rambo
Permit Technician
Enclosures
File: D11 -081
W:\Permit Center \Incomplete Letters \2011 \D11 -081 Incomplete Ltr #1.DOC
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
• •
PLANNING DIVISION COMMENTS
DATE: April 5, 2011
APPLICANT: Denkey Adame
RE: D11 -081
ADDRESS: 4629 S 160`h Street
Please review the following comments listed below and submit your revisions accordingly.
1) Please provide a site plan for the property, showing the location of all structures on site
and the proposed addition in relationship to the property lines. Make sure to show on the
site plan the distance from all structures and the proposed addition to the property lines.
If you have any questions related to the comments above, Jaimie Reavis is the planner assigned to the file
and can be reached at 206 - 431 -3659.
1
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -081 DATE: 04 -18 -11
PROJECT NAME: ADAME RESIDENCE
SITE ADDRESS: 4629 S 160 ST
Original Plan Submittal X Response to Incomplete Letter # 1
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENT : 414
Ilding ivision I
Public Wofks
Fire Prevention
Structural
J�. 4-t,(4-44
Planning Division
Permit Coordinator
iJ 1
.
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 04 -19 -11
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
❑ No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05-17-11
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
*PEWIT f d 1 �� COP)
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -081
PROJECT NAME: ADAME RESIDENCE
SITE ADDRESS: 4629 S 160 ST
X Original Plan Submittal Response to Incomplete Letter #
DATE: 03 -31 -11
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building Division IN
�ion I
AbCW /10 s V-41
ilk ,J/h- _s_t ■
Fire Prevention j
Structural
Planning Division
Permit Coordinator
fai
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
n
Incomplete
DUE DATE: 04 -05 -11
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg El Fire ❑ Ping PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
No further Review Required
n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05-03-11
Approved n Approved with Conditions n Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: L7 -- /A — /
Plan Check/Permit Number: D 1 1 -081
• Response to Incomplete Letter # 1
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Adame Residence
Project Address: 4629 S 160 St
Contact Person: j7L 4/A -A- Phone Number:
Summary of Revision:
.2‘
,Po o6j /Id/ -7-11 5 /r)-
RECEIVED
ettTV AP TUKWILA
APR ►#..8 2011
mMfl CENTER
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revis n
Received at the City of Tukwila Permit Center by:
N-- Entered in Permits Plus on L-k`- ( 1 (
\applications \forms - applications on line\revision submittal
Created: 8 -13 -2004
Revised:
•
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431 -3670 FAX (206) 431 -3665
E -mail: tukplanc ci.tukwila.wa.us
Permit Center /Building Division
206 431 -367o
Public Works Department
206 433 -0179
Planning Division
206 431 -367o
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
,9fl14/q_
[please print name]
, states as follows:
PERMIT NO: i) -Qe I
1. 1 have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a.copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requireme of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number , and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
Signed and sworn to before me this
N
day of
,2011 .
PUBLIC in and for the State of Washington
Residing at tl "1
Name as commissioned:
My commission expires: i75 owl -J-1
County
18.27.090 Exemptions, The regilllion provisions of this chapter do not apply e
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile /manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
g. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile /manufactured home dealer or manufacturer
who subcontracts the installation, set -up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set -up, or repair of the
mobile /manufactured homes that were manufactured or
sold by the mobile /manufactured home dealer or
manufacturer;
18. An entity a' who holds valid,electrical contractor's
license under charple 19:28 12 ''
at employs
a certified
ed
journeyman el � et residential specialty
electrician, organ ctrical traini (Ong the
requirement$of
�ptei 19.2811,. to perform plumbing
work that is incidentally; directly; And it.nmediately
appropriate t' b like-in-kind replacement of a household
appliance or othy tismaikiouseholdry . ization equipment
that requires liimftg ectrie Kt" ` :: d limited waste
and/or water cote ari�st�Atl el :. u ical trainee must be
supervised by a ce fie iree oil n while performing
plumbing work.
• Per Washington State Department of Labor and industries. lessee has been
interpreted to be equivalent to owner for the purpose of these exemptions.
SITE PLAN
Northeast of the Northeast
_.. W.M, King County, WA
iREVIEWED R
DE OMPLIANGE
1 CO
�}
-r�
BUILDING
AP
2 9 2 11
160TH ST
Cn
frn
0
c, rig
a C
m r m
7
of Section 27,
Township 23 North, Range 4 East,
GRAPHIC SCALE
20 0 10 20
40
80
RECIthi ED r
P,fcchanica1
E - ctrical
r
Gas Piping
City of Tukwila
BUILDING DIVISION
•
a °..
•
EXISTING � °• • . °
DRIV€WAY • • • • •
( IN FEET )
1 inch = 20 ft.
S0' 15' 50 "E
140.0'
\ \ \ \ \ \ \\\ \ \ \ \ \ \\
\\\\\\\\\\\\
\
do
J t1
\ \ \ \\\ \ \ � \ \ \�\\\.
.] • ,EXISTING Q •. • •. °
DRIVEWAY \ \\ \ \a
.1 1
O:
140.--44q4 -
n review approval is subject to errors and
proval of construction documents does not autlhonze
violation of any adopted code or ordinance. R
proved Reid Copy and conditions is acknowledged:
By
Date:
• !--01Ic
City Of Mitt ilk
REVISIONS
No changes shall be made to tho Wpe
of work without prior approval o'
Tukwila Building Division.
NOTE: Revisions will require a new plan su)mittal
and may include additional plan review fe es.
EXISTING MAIN
HOUSE
NEW STORAGE
ADDITION
EXISTING
CARPORT
140.0'
N0' 15' 50 "W
0
0
rn
CO
z
STORAGE ROOM ADDITION
UNDER EXISTING CARPORT
OWNER: Denkey Adame
Draw By: Nega Weyesa
Date: 4/14/2011
II/a. Mb. ./lb link Oft wwWww•
1
EXISTING MAIN HOUSE
EXISTING CARPORT
FLOOR PLAN
SCALE 1/4" = 1' -0"
STORAGE
NEW ADDITION
30X30
15' -10"
I RE 1EWED
R
CODE
�P CONIPLI,qNCE
PROVED RECEIVED
APR 2 2u 11 MAR 31 2011
C� of Tukwila PERMIT CENTER
BUILDING DIVI4inn�
Q11 -081
STORAGE ROOM ADDITION
UNDER EXISTING CARPORT
2�s
EXISTING
CARPORT
1
NEW STORAGE
ADDITION --
WEST SIDE ELEVATION
SCALE 1/4" = 1'-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 2 2U ■1
Cityo,Tukwila
BUILDING mini m
RECEIVED
MAR 31 2011
PERMIT CENTER
STORAGE ROOM ADDITION
UNDER EXISTING CARPORT
OWNER: Denkey Adame
DRAW BY: Nega Weyesa
DATE: 3/28/2011
3�s
NEW STORAGE
ADDITION
UNDER CARPORT
EXISTING
CARPORT
EXISTING I REVIEWED FOR
MAIN HOUS 9DE COMPLIANCE
APPROVED
1 APR 2 ti 2u , i
City of Tukwila
SECTION A -A BUILDIN( rinncinAj STORAGE ROOM ADDITION
UNDER EXISTING CARPORT
RECEIVED
MAR 31 2011
PERMIT CENTEF
SCALE 1/4" = 1' -0"
OWNER: Denkey Adame
DRAW BY: Nega Weyesa
DATE: 3/28/2011
z{ S
4" CONC. SLAB 0/
-.:
2x4 RAFTERS ® 24" 0.0
2x4 STUDS ® 16" O.0
8d CO 4" O.C. SHEATHING
TO BLOCKING
___.
ICCRpEVIEWED FOR
CODE COMPLIANCE
. APPROVED
A R /.. 1
1
Cky of Tukwila
� BUILDIN( nfefeww
WALL FRAMING PER DETAIL 1
GRAVEL FILL.
(2) 16d ®16" O.0
d .
•
. v p v
:..:.:
UL1
-: :!f
17u
.1.6s•-,...•-•.• t -;:..!..
ULI—
=: •t',:;.•A,
— —
∎•• <::..:.::`:::::
—LIi�
tits.-
L1U
;"
=
11
j SCALE: 1"= '-0"
SCALE: 1"=1'-0"
FR.FiMING TO CONCERET
2
ROOF DETAIL
RECEIVED
MAR 31 2011
PERMIT CENTER
STORAGE ROOM ADDITION
UNDER EXISTING CARPORT
OWNER: Denkey Adame
DRAW n.o.w.�..
DATE: srevm��
OWNER: Denkey Adame
DRAW BY: Nega Weyesa
DATE: 3/28/2011
D