Loading...
HomeMy WebLinkAboutPermit D11-098 - SAVVIS - SE3 PHASE 1 - TENANT IMPROVEMENTSAVVIS SE3 PHASE I 3355 S 120 PL Di 1-098 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Project Name: SAVVIS - SE3 PHASE 1 DEVELOPMENT PERMIT Permit Number: D 11 -098 Issue Date: 06/16/2011 Permit Expires On: 12/13/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: JOSH JOHNSON Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA WA 98168 Phone: 206 369 -1548 Contractor: Name: SABEY CONSTRUCTION INC. Phone: (206)281 -4200 Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 -5121 Contractor License No: SABEYCI033KM Expiration Date: 01/12/2013 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF 30,000 SF OF DATA CENTER ON THE 3RD FLOOR. WORK TO INCLUDE WALL DEMOLITION, NEW INTERIOR WALLS, GLAZING AT WALLS, ACOUSTICAL CEILING TILE, AND ADDED DOORS WITH HARDWARE. Value of Construction: $410,500.00 Fees Collected: $6,666.62 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: IB Occupancy per IBC: 0008 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11 -098 Printed: 06 -16 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: t�lt� ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or the performance of work. to this permit. Signature: Print Name: .1.. 1,4 Jo ».k.., e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: & /h b This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11 -098 Printed: 06 -16 -2011 7: All construction shall be done in conform Joe with the approved plans and the require s of the International Building Code or International Residential, International Mechanical Code, Washingtate Energy Code. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDI'T'IONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. Tf the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not doc: IBC -7/10 D11 -098 Printed: 06 -16 -2011 energized. If an arrow is provided as part of t iff xit sign, the construction shall be such that throw direction cannot be readily changed. (IFC 1011.5.1) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Add.ition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 30: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 31: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 32: Maintain automatic fire detector coverage per N.:F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 33: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 36: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 39: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 011 -098 Printed: 06 -16 -2011 CITY OF TUV A Community Dem- ent Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building PeO No. Mechanical Permit No. -oqi Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: JO Z'3 D list:DO Z Site Address: 335,5 C. /2 e ie Jr J 14)11" Suite Number: Floor: 3 New Tenant: Yes .. No Tenant Name: V V kS Property Owners Name: S/9 6te-i,a Z-m,- 23 XJ Mailing Address: /2-22:11 72c8u>> */a /.1/Ty2/JAr /.4,JAL B /VD Lv t1 /48. City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: -../261) Y d A is&Ai Day Telephone: Z 3 - ASTg Mailing Address: /Z2 % 'Tied j ./'%k /,b • B /Vb, p ~lam the • I7'81lvg �- -� City State Zip E -Mail Address: 1--1 J /t1 DE" ez. /r Fax Number: GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: SSAgE /b`7-fgltGTb ,t-' Mailing Address: /Z291 4 &J . k /J. 1 T cam/ (/b.. S 7TL- ze)ye. �g J hi> City State Zip Contact Person: —T -}� 'JL,Sa Av Day Telephone: 2Z)4 — 3� - /S•$ E -Mail Address: 1/�6 %/ -- ? 1 2.6 i4 Fax Number: Contractor Registration Number: £/q i3�L,�� c .033,4'A-1 Expiration Date: 1/1g/ 2) l ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: J7 /01)E 25d Contact Person: /3013 E -Mail Address: (� City State Zip Day Telephone: ZdZ, - r%o - Fax Number: ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: H:\ Applications\Forms- Application On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh State Zip Page 1 of 6 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid prig" $ /ID t Si ' d Existing ing Valuation: $ Scope of Work (please provide detailed information): Lc) p n 12 -Jb L i;r /2:90 � %J J /p7E47., p - 1.4.) i1 I iS ) Alba it- & 1.)4ils) /F..cr e4.1 1 j A661`S,TlLJI 1 cE11i J Ti LE ADper, vi Y- AARAW;A 6Z25> Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicationa\Forms- Applications On Line12010 Applications \7-2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing ^ ��' V Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of - Occupancy per IBC 1 Floor 22 Floor 3`d Floor VN Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicationa\Forms- Applications On Line12010 Applications \7-2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 IDate Application Accepted: PERMIT APPLICATION NOTES —.cable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AA ENT: Signature: /y�.-)9 • Print Name: /1A T �.T /45 )L Date: -V /1// Day Telephone- 7-25- Z55 " 5.4 Mailing Address: /2-&) I %G,�Gt p %i /,l�T- ,� %VD. 77- City Date Application Expires: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh State Zip Staff Initials: ,_.„,,A, Page 6 of 6 1 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY - SE3 PHASE 1 RECEIPT Permit Number: D11 -098 Status: PENDING Applied Date: 04/14/2011 Issue Date: Receipt No.: R11 -00729 Payment Amount: $6,666.62 Initials: JEM Payment Date: 04/14/2011 03:38 PM User ID: 1165 Balance: $0.00 Payee: SABEY CONSTRUCTION INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 45379 6,666.62 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $6,666.62 4,037.65 2,624.47 4.50 doc: Receiot -06 Printed: 04 -14 -2011 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12.. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 -b // -Dr7,' -gp Project: $'9 vii, ..5'eJ r'h'isc Type of Inspection: _Z / A% L Address: ..3355 s Sao PL .. Date Called: -- Special Instructions: Date Wanted:. a Requester: 1 Phone No: m2067— C7i,5- -/ /92 SAppr:oved per applicable codes. aCorrections required prior to approval. 1/ COMMENTS: (1) { iZA-w 104 — "'i ✓tide Ii Co Z, mac, — (a. t-f thiALO It 1 ?i2 ✓ Att t `c9vv,, ,4r J I' ► 1 Datg;`2 ct �j PECTION FEE REQURED. Prior tb next inspection. fee must be t 6300 Southcenter B d.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project Type of Inspection: KAi\lek r9 A e . -(? ' 7 S)6ki imo jie Addr755 r 24 7 Date Called: OD dr 1,J/ 3PiIIs-sr Special Instructions: a Date Wanted:_ 23 , (( �a.m. Requester: \/, Phone J'- 4 Z-3 ..-5-4 ( • . App?.ove'd per applicable codes. yCorrections required prior to approval. COMMENTS: KAi\lek r9 A e . -(? ' 7 S)6ki imo jie AriA W OD dr 1,J/ 3PiIIs-sr .--'. 15)- \/, ems..... i '.oc N S.", (5/j tb. Gre-ite(s f(14 I\"\ Ilns ector: 1Date:�^� n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Ott-- le, 4k-4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 3- Liu Type of nspection: 1 ...) 1/4..35— c-e^ ---ki Ad sts,s 1 i 1- Date Called: Special Instructions: 1 Date Wanted:. s ^ * tp.Mi a.m. Requester: • Phone No: b •des. ® Corrections required prior to approval. COMMENTS: c Insp e tt or: Date: { n REINSPECTION FEE REQUIRE . Prior to next inspection, fee nitist be • paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. . �k 3 INSPECTION NO. :INSPECTION RECORD `Retain a copy with permit PERMIT NO. DE ( -- a '78 CITY OF TUKWILA. BUILDING. DIVISION • 6300 Southcenter Blvd., #100 1ui Wil'a:. \VA 98188 ._ F` , (206) 431 -3670 Permit Inspection Request Lire (206) 43.1 -2451 Proj °i Type o Inspectign'. . Address: '+V 11-5:-C t?.d —./0L Date Called: Special Instructions: PRequester: Date Wanted:. Phope 0 Co 1 '' 11. C r t 4 9 0., , EiApproved per applicable codes. E Corrections required• prior to approval. COMMENTS: VA 3 (IL cjc iirovirrpoiti e) - 1-efeAr ro o /Th Inspect • 'Date 7, 1' • • ri REINSPECTION FEE REQUIRE.. Prior to next inspection, fee must be_ paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. , ' INSPECTION RECORD. Retain a copy with permit: PERMIT NO. o48 CITY OF TUKWILA BUILDING •DJVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • .0„, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ' ProJ S#vv's SE-3 Type of Inspection:: ` - S,.. ),s, . - :L. ^c„ Address: -1-s+ 3353- 12-~J PL Date Called: Special Instructions: P+�lr Vito Date Wanted: �"'""^. e.rr ,. .' (© '- (I p.m. Requester: P h , 9 N o . - 9/ e- / 4 C 0 ❑ Approved per applicable codes. aCorrections required prior to approval. COMMENTS: Pv'kr/if A 3fe.A -EU i L1 r, J rai f A ri-e.AY Inspect Date: • ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule: reinspection.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Az_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 DP- Oqg Proj , S Type of�nspectiop: 6 €4 ic:014 Address: 'it, 33 SS s- / 76 -PL Date Called: t-N1 1 CV- (0 J YlID (X fe - -'it-i) Special Instructions: hl5 3 1 k J( Date Wanted: a.m. Requester: I ° ! i( Phone r 115- _ 14q O Approved per applicable codes. Corrections required prior to approval COMMENTS: tA )AtkS i or v36 -k-;(( Xike`." .. t-N1 1 CV- (0 J YlID (X fe - -'it-i) r4 .Sfr'-i -0, /\ .4 S U VJ A/0 6.) 4 (t) _ CA rr { 431- I ° ! i( / 65 (.)An c -(b STfJkS..,---- I 110,1 ....---1 A Inspe foq r: Date: 1•'/ . • REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • .,1.7.....11.'''''.41&';•415 '1-:••!"-• N,- p ,v:. e0(* ag'PE'C-TiON-RE€ RD- < %� Retain a copy with permit 0/1 py p INSPECTION' NO. PERMIT NO. r CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 t_ 'fz_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project JV's S�� Type nspectiona rokM4A v ice. 4 n Ad ess: 55 �. ?� r33 �-- P Date Called: Special Instructions: t�P 3 � roe( et,., Ai -e._ Date Wanted: .� 1 (a -� — (/ rya' 1. p.m. Requester: Phone No- '062 — 9' C-- %--- oc -.S0 ( ElApproved per applicable codes. • Corrections required prior to approval. c"..V..: COMMENTS: � �`\4 Ann' :,) tom- fc f eek'rlo v M @__ os vet; . ice. 4 n V rf'i p n (6___ (cry) A 1 %--- oc -.S0 ( AfC A ov- - v @ L -a ,) , -e..--r ---- Inspector: Date: . Y • n REINSPECTION FEE REQUIRED. Pr for to next inspection, fee must be paid at 6300 Southcenter Blvd., Sude 100. Call to schedule reinspection, ';, s • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /I -5- /S• 7 o9Y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: c - SType ASVt/)., Sprinklers: Fire Alarm: of nsp coon: 451 I., 1 51v e- civ- Addres ;s5'5 Suite #: 5 ( o+ O%/ Contact P rson: Special Instructions: Eft.... L_ slim l - Phone No.: M. Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: .S? ce;) AL — OK Eft.... L_ slim l - a(c. i` o e. c. P4Z - Ok__ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: kA ca-- Date: glad i i Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 ..wr� • • '4., .•y� • : • 5. • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS —CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Project: SAI/vi s Sprinklers: Type of Inspection: S P ('i,.r- Address: 3 ,ASS' Suite #: S �� ©--- 0 Contact Person: Special Instructions: Occupancy Type: Phone No.: • Approved per applicable codes. Corrections required prior to approval. COMMENTS: �k rto Co er- i< • 1' i Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: i a_ Date: 7 1aol / i Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc ..x 6/11/10 T.F.D. Form F.P. 113 • • • • • PERM1TC00RDCOPIO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -098 DATE: 04/14/11 PROJECT NAME: SAVVIS - SE3 PHASE 1 SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS, fir,reUiorfW(/10/'11'11/1, J� /1% `4_� 11 vision 1 Planning Divlslo Public Wo1rks* Z411 Structural Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 04/19/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/17/11 Approved n Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or TradespeoplR Printer Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SABEY CONSTRUCTION INC 2062814200 12201 Tukwila Intl Blvd 4TH FLOOR Seattle WA 981685121 King Corporation UBI No. 601532164 Status Active License No. SABEYCI033KM License Type Construction Contractor Effective Date 5/14/1997 Expiration Date 1/12/2013 Suspend Date Specialty 1 General Specialty 2 Unused r Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SABEYC *953RE SABEY CORPORATION Construction Contractor General Unused 12/5/2005 12/5/2011 Active DASCOC *066KD D A S CONSTRUCTION CORP Construction Contractor General Unused 5/4/1994 5/4/1997 Archived BERKLCI088CE BERKLEY CONSTRUCTION INC Construction Contractor General Unused 2/5/1992 2/5/1993 Archived ARCHIDG132QZ ARCHITECTUAL DEV GROUP INC Construction Contractor General Unused 11/9/1987 11/9/1992 Archived SABEYC *141PH SABEY CORPORATION Construction Contractor General Unused 10/8/1986 12/31/2001 Archived OWPROI*221RR 0 >* W PROPERTIES INC Construction Contractor General Unused 12/19/1978 10/1/1986 Archived BERKLS *267LP BERKLEY STRUCTURES INC Construction Contractor General Unused 6/17/1974 12/31/1991 Archived Business Owner Information Name Role Effective Date Expiration Date SABEY, DAVID ARTHUR President 05/14/1997 SEWELL, PATRICIA ANNE Secretary 01/19/2011 POOLE, LAURENT D Secretary 01/01/1980 01/19/2011 HARMON, JAMES N Treasurer 01/01/1980 01/19/2011 Bond Information https://fortress.wa.gov/lni/bbip/Print.aspx 06/16/2011 SE3 PHASE 1 PERMIT SET SE3 Phase 1 3355 South 120th Place Tukwila, WA 98168 Permit Set April 8, 2011 SEPARATE PERMIT REQUIRED FOR: Mechanical RI Electrical Plumbing Gas Piping cry of Tukwila BIB`'_ .' =1NG DIVISION REVIEWED FOR CODE COMPLIANCE _. APPROVED MAf032011 VL City of T la BUILDING ISION: FILE COPY Permit No. TA f'01 Plan review approval is subject to errors and omission. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledgcd: By, ,J,,.s,.. ��-- Date' ,/' City Of Tukwila BUILDING DIVISION CALLISON $$$ DESIGN $SPECIFICATION$$$$$$$$$$$$$ REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. $$$DATE$$$$$TIME COPYRIGHI0 2011 CALLISON "P\ CITYRFRI APR 14 2011 PERMIT CENTER 1 2 3 4 5 6 8 9 10 J: \Projects \Savvis \Caddsawis \S heets \se3_a- 000.dwg 4/7/11 2:59 PM COPYRIGHT 2010 CALLISON 0 O O ti co N CO M F W a 1.. > N Z m to la . 1 v C co 04 en co O T— E -W ca w O I Cr) 1` O U a _ O L Q O O > Q I- .Y O , N a, 12 O— �� :Ci } W N N - CO CO mO 0 L -' O O a�N O a)NN • E Z ° Z O 0 co 0 cn J J J ."I co U ✓ 0 uJ M I- < 0 z W 0 I0 0 N N- . CI) L() M N 41; 1- 0 Lu 0 ISSUED / REVISED DATE PERMIT SET 11- APR -11 GENERAL NOTES A -000 GENERAL DRAWING SYMBOLS RCP SYMBOLS ABBREVIATIONS PROJECT DIRECTORY DRAWING INDEX XX XX ® CEILING- MOUNTED 2.X2. FLUORESCENT LIGHT AC ASPHALTIC CONCRETE ACC ACCESSIBLE ACP ACOUSTICAL CEILING PANEL D NCL NFO NSIDE DIAMETER NCLUDE, INCLUDING NFORMATION OWNER SAWIS 1 SAWIS PARKWAY TOWN &COUNTRY, MO 63011 ARCHITECTURAL A -000 GENERAL INFORMATION SHEET A -001 SITE PLAN • A -XXX A -XXX BUILDING SECTION INDICATOR WALL SECTION INDICATOR EILI CEILING-MOUNTED CEILI FLUORESCENT LIGHT CEILING- MOUNTED 1'X4' FLUORESCENT LIGHT (HIDDEN) CEILING - MOUNTED I STRIP FLUORESCENT LIGHT (EXPOSED) CEILING - MOUNTED I STRIP FLUORESCENT LIGHT WALL - MOUNTED STRIP FLUORESCENT LIGHT DOWNLIGHT ACCENT DOWNLIGHT WALL- WASHER DOWNLIGHT SCONCE -TYPE (WALL - MOUNTED) LIGHT CEILING - MOUNTED EXIT LIGHT WALL- MOUNTED EXIT LIGHT FIXTURES I HVAC DIFFUSERS (SIZE AND TYPE PER MECHANICAL .DRAWINGS) ACST ACOUSTICAL AD AREA DRAIN ADDM ADDENDUM ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE APT APARTMENT ARCH ARCHITECT, ARCHITECTURAL AUTO AUTOMATIC AV AUDIO VISUAL AWP ACOUSTICAL WALL PANEL(S) BB BULLETIN BOARD BD BOARD BLDG BUILDING BLKG BLOCKING BO BOTTOM OF BOT BOTTOM BRG BEARING BRZ BRONZE BSMT BASEMENT BUR BUILT UP ROOFING CAB CABINET CB CATCH BASIN CEM CEMENT, CEMENTITIOUS CER CERAMIC CG CORNER GUARD CH COAT HOOK CI CAST IRON CJ CONTROL JOINT CIP CAST -IN -PLACE . CL CENTERLINE CLG CEILING CLO CLG CLOSET CLEAR CMU CONCRETE MASONRY UNIT CO CLEAN OUT, CASED OPENING COL COLUMN COMM COMMUNICATION CONC CONCRETE CONN CONNECTION, CONNECT CONSTR CONSTRUCTION CONT CONTINUOUS, CONTINUE CORR CORRIDOR CPT CARPET CSWK CASEWORK CTR CENTER CU CUBIC D DEEP, DEPTH DBL DOUBLE DEMO DEMOLISH, DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL, DIAGRAM DIM DIMENSION DIV DIVIDE, DIVISION DMPF DAMPPROOF, DAMPPROOFING DN DOWN DR DOOR, DRESSING ROOM DS DOWNSPOUT DW DISHWASHER DWG DRAWING DWR DRAWER E EAST EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR ENCL ENCLOSE, ENCLOSURE EP ELECTRIC PANEL EQ EQUAL EQUIP EQUIPMENT ESCAL ESCALATOR EXH EXHAUST EXP EXPANSION, EXPOSED EXIST EXISTING FA FIRE ALARM FCIO FURNISHED BY CONTRACTOR/ INSTALLED BY OWNER FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDTN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FH FIRE HYDRANT FHC FIRE HOSE CABINET FIG FIGURE FIN FINISH, FINISHED FLEX FLEXIBLE FLR FLOOR, FLOORING FLUOR FLUORESCENT FO FACE OF FINISHED OPENING FOIC FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR FP FIRE PROTECTION, FIREPROOF FR FRAME, FIRE RATED FRMG FRAMING FRT FIRE RETARDANT TREATED FT FOOT, FEET FTG FOOTING FUT FUTURE NSUL NT WD JAN JT KIT L LAM LAU LAV LT LTG MAS MATL MAX MECH MED MEMB MEZZ MGT MFR MH MIN MISC MO MS MTD MTL MVBL N NIC NO NOM NTS OC OH OD OPNG OPP ORD OTS PBD PRCST PD PERP PLAM PLAS PLYWD PNL PL PR PRKG PROP PT PTN R RCP RD REF REF REINF REQD REV RFG RM RO RT S SC SCHED SD SECT SGL SHT SHTHG SIM SPEC SPKLR SPKR SO SS SST STC STD STL STOR STRUCT SUSP T T &G TEL TEMP TER THK TMPD TO TSTAT TV TYP UGND UNFIN UON VERY VEST VNR VR VWC W W/ W/O WC WD WH WP WR WT WWF XFMR NSULATE, INSULATION NTERIOR NDIRECT WASTE DRAIN JANITOR JOINT KITCHEN LONG LAMINATE, LAMINATED LAUNDRY LAVATORY LIGHT LIGHTING MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MEMBRANE MEZZANINE MANAGEMENT MANUFACTURE, MANUFACTURE MANHOLE MINIMUM, MINUTE MISCELLANEOUS MASONRY OPENING MOP SINK MOUNTED TELE: (314) 628 -8700 SABEY CONSTRUCTION OWNER'S 12201 TUKWILA INTERNATIONAL BLVD. REP. FOURTH FLOOR SEATTLE, WA 98168 TELE: (206) 281 -4200 FAX: (206) 281 -0920 CALLISON, LLC ARCH. 1420 5TH AVENUE, SUITE 2400 SEATTLE, WA 98101 TELE: (206) 623 -4646 FAX: (206) 623 -4625 A -002 PARTIAL FIRST FLOOR LIFE A -003 PARTIAL SECOND FLOOR A -004 PARTIAL THIRD FLOOR A -005 PARTIAL THIRD FLOOR A -102 PARTIAL SECOND FLOOR A -103 PARTIAL THIRD FLOOR A -104 PARTIAL THIRD FLOOR A -105 PARTIAL THIRD FLOOR A -106 PARTIAL SECOND FLOOR A -107 PARTIAL THIRD FLOOR A -108 PARTIAL THIRD FLOOR A -800 DETAILS A -801 DETAILS • SAFETY PLAN DEMOLITION PLAN DEMOLITION PLAN LOBBY DEMOLITION PLAN BREAKROOM PLAN BREAKROOM PLAN PLAN ENLARGED PLANS RCP ®BREAKROOM RCP 0 BREAKROOM RCP ® NOC /LOBBY • • ENLARGED ® XX %CV DETAIL INDICATOR A -XXX SECTION DETAIL INDICATOR MOUNTED HVAC RETURNS/EXHAUSTS (SIZE AND TYPE PER MECHANICAL DRAWINGS) HVAC ITEMS 1 XX • © © FA XX A -XXX EXTERIOR ELEVATION INDICATOR X -XXX ©A 1 -r CEILING - INTERIOR © ELEVATION INDICATOR I MATCH NE DRAWING I- 1 CEILING- ACCESS PANEL O CD T o STANDARD LIGHT SEE XX /AL XXX MATCH LINE INDICATOR METAL MOVABLE NORTH NOT IN CONTACT NUMBER NOMINAL NOT TO SCALE ON CENTER OVERHEAD OUTSIDE DIAMETER OPENING OPPOSITE OVERFLOW ROOF DRAIN OPEN TO STRUCTURE ABOVE PARTICLEBOARD PRECAST PLANTER DRAIN PERPENDICULAR PLASTIC LAMINATE PLASTER PLYWOOD PANEL PROPERTY LINE PAIR PARKING PROPERTY PAINT, POINT, PRESSURE TREATED PARTITION RADIUS, RISER REFLECTED CEILING PLAN ROOF DRAIN, ROAD REFER TO, REFERENCE REFRIGERATOR REINFORCED, REINFORCING REQUIRED REVISED, REVISION ROOFING ROOM ROUGH OPENING RIGHT SOUTH SOLID CORE SCHEDULE STORM DRAIN SECTION SINGLE SHEET SHEATHING SIMILAR SPECIFICATION SPRINKLER SPEAKER SQUARE SERVICE SINK STAINLESS STEEL SOUND TRANSMISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SUSPENDED TREAD TONGUE AND GROOVE TELEPHONE TEMPERATURE, TEMPORARY TERRAllO THICK, THICKNESS TEMPERED TOP OF THERMOSTAT TELEVISION TYPICAL UNDERGROUND UNFINISHED UNLESS OTHERWISE NOTED VERTICAL VESTIBULE VENEER VAPOR RETARDER VINYL WALLCOVERING WEST, WIDE WITH WITHOUT WATER CLOSET, WALLCOVERING WOOD WALL HYDRANT WEATHERPROOF, WATERPROOF, WATERPROOFING, WORK POINT WATER RESISTANT WEIGHT WELDED WIRE FABRIC TRANSFORMER SCOPE 0 F WORK REVISION INDICATOR MOUNTED (1) EXISTING X.X NEW CEILING - MOUNTED FIRE SPRINKLER TENANT IMPROVEMENT CONSISTING OF 30,000 SF DATA CENTER ON FLOOR 3. 1 (1) COLUMN GRIDLINE INDICATOR (—_).X COLUMN GRIDLINE INDICATOR "$" DATUM INDICATOR OR WORK POINT SPOT EL XXX.XX EL XXX' -XX" O CEILING - MOUNTED SPEAKER ELEVATION INDICATOR I t REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 3 2011 City of Tukwila BUILDING DIVISION BUILDING ADDRESS ROOM NAME �EIXXXXX� EQUIPMENT INDICATOR <XIXXXXX> FIXTURE INDICATOR <FIXXXXX> FURNITURE INDICATOR <GIXXXXX> GRAPHIC /SIGNAGE INDICATOR MISCELLANEOUS INDICATORS ' INTERGATE EAST CAMPUS 3355 S. 120th PLACE TUKWILA, WASHINGTON 98168 2022 ROOM INDICATOR A'> (DOOR) OPENING INDICATOR FINISH ( FIXXXXXXX) INDICATOR BUILDING CODE CRITERIA VICINITY MAP . WINDOW INDICATOR CEILING APPLICABLE CODES: BUILDING CODE: 2009 INTERNATIONAL BUILDING CODE WAC 51 -50 IBC AMENDMENTS 2006 EDITION ENERGY: WASHINGTON STATE ENERGY CODE WAC 51 -11 2006 EDITION MECHANICAL: 2009 INTERNATIONAL MECHANICAL CODE W/ 2009 WASHINGTON STATE AMENDMENTS FIRE: 2009 INTERNATIONAL FIRE CODE WAC 51 -54 2006 IFC STATE AMENDMENTS PLUMBING: 2009 UNIFORM PLUMBING CODE WAC 51 -56 & 51 -57 2006 UPC STATE AMENDMENTS ELECTRICAL: 2008 NATIONAL ELECTRICAL CODE WAC 296-46B ELECTRICAL SAFETY STANDARDS FUEL GAS: 2009 INTERNATIONAL FUEL GAS CODEtG�" WITH WASHINGTON STATE AMENDMENTS. ACCESSIBILITY: IBC REQUIREMENTS FOR BARRIER FREE ACCESS, CHAPTER 11 ICC /ANSI 117.1 2003 WAC 51 -50 IBC AMENDMENTS 2006 EDITION 2007 NFPA 72 NATIONAL FIRE ALARM CODE 2006 NFPA 101 LIFE SAFETY CODEAI' OTHER: 2005 NFPA 110 STANDARD FOR EMERGENCY & STANDBY POWER SYSTEMS 2005 NFPA 111 STANDARD ON STORED ELECTRICAL ENERGY EMERGENCY�� & STANDBY POWER SYSTEMS 2006 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE SEISMIC DESIGN CATEGORY D CONSTRUCTION & OCCUPANCY TYPES CONSTRUCTION TYPE 1A, FULLY SPRINKLERED OCCUPANCIES: B (BUSINESS - 1ST FLOOR UPS RM B BUSINESS - 2ND FLOOR DATA CENTER H3 (LOW H ARD STORAGE) - 1ST FLOOR GENERATOR (XX'-XX" AFF) rye �� Ix p 3� . ' i i 1 �' � � �� a � '' g i ,` x_ yi�*� �1P , ` S x ,t �u§ �` �' '� y k AREA OF � � �� x 1 cools E T ix , ,y_t ry' ' Y HEIGHT INDICATOR IXXIXXIXX� WALL TYPE INDICATOR MATERIAL (PER FINISH ( FINISH (PER FINISH LEGEND ) LEGEND) In Gina CEILING HEIGHT HEIGHT /MATERIAL /FINISH INDICATOR KEYNOTE 0 PARTITION) PARTITION) PARTITION) PARTITION) (NON -RATED PARTITION) (1 -HOUR RATED (2 -HOUR RATED (3 -HOUR RATED (4 -HOUR RATED PARTITIONS m � °, : , x " t "e � "«���� z - WORK ^ ��° � ���yyy###, �%� • * ° fr., GENERAL NOTES PLAN SYMBOLS LEGAL DESCRIPTION FVC FIRE HOSE VALVE CABINET FWC FABRIC WALL COVERING FWP FABRIC WRAPPED PANEL(S) GA GAGE GALV GALVANIZED GEN GENERAL, GENERATOR GFRC GLASS -FIBER REINFORCED CONCRETE GFRG GLASS -FIBER REINFORCED GYPSUM GFRP GLASS -FIBER REINFORCED PLASTIC GL GLASS GYP GYPSUM GYP BD GYPSUM BOARD H HIGH HB HOSE BIBB HC HOLLOW CORE HD HAND DRYER HDBD HARDBOARD HDW HARDWARE HDWD HARDWOOD HM HOLLOW METAL HO HOLD OPEN HORIZ HORIZONTAL HR HOUR HT HEEIGHTGG•• yyEE � HVAC AND IAIR CONDITIONING 1. DO NOT SCALE THE DRAWINGS. 8. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN WITHOUT GUARANTEE OF ACCURACY. 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS. NOTIFY PORTION OF THE WORK. THE ARCHITECT FOR RESOLUTION OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO 3, THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT PROCEEDING WITH THE ITEM OF WORK AFFECTED. IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE 9. COORDINATE ALL WORK AS REQUIRED WITH BUILDING MANAGEMENT WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE INCLUDING THE USE OF ELEVATORS, TEMPORARY STORAGE USE OF ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO LOADING DOCKS, AND BUILDING KEYING SYSTEM, ETC. CONSTRUCTION. 10. ALL DETAILS AND REFERENCES ARE GENERALLY NOTED ONCE, 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH THE SURFACES, UNLESS OTHERWISE INDICATED. FIRST TIME THEY APPEAR AND THEY ARE TYPICAL FOR SIMILAR CONDITION ELSEWHERE VON. 5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE LOCATED SO THAT THE EDGE OF 11. ARCHITECTURAL SPECS NOT ISSUED FOR THIS PROJECT. THE FINISH OPENING IS SIX INCHES FROM THE FACE OF THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER 12. MECHANICAL, ELECTRICAL, AND PLUMBING IS TO BE FULLY DOORS AND CASED OPENINGS SHALL BE CENTERED BETWEEN ENGINEERED FOR PRICING PERMITTING AND CONSTRUCTION. ADJACENTWALL INTERSECTIONS. NOTIFY ARCHITECT IF DISCREPANCY EXISTS BETWEEN INFORMATION SHOWN ON DOCUMENTS. ARCHITECTURAL 6. 'B /S' INDICATES BUILDING STANDARD AS PROVIDED BY LANDLORD DRAWINGS TAKE PRECEDENCE. DRAWN AND /OR SPECIFIED IN THE CONTRACT DOCUMENTS OR 13. REPAIR DAMAGED FIREPROOFING AS NEEDED WITH APPROVED MATCHED TO EXISTING CONSTRUCTION IN THE BUILDING. ALL MATERIALS. WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL DOCUMENTS FOR BUILDING STANDARD TENANT IMPROVEMENTS WHEN APPLICABLE OR NOT INDICATED OTHERWISE IN THE ARCHITECTURAL DOCUMENTS. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH APPLICABLE SAFETY CODES, PERFORM ALL WORK TO MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES, LAWS, REGULATIONS, SAFETY ORDERS AND DIRECTIVES FROM AUTHORITIES HAVING JURISDICTION OVER THE WORK. PARCEL LOTS 4: 1 THROUGH 8, INCLUSIVE, IN BLOCK 5 AND LOTS 1 THROUGH 8, INCLUSIVE AND 25 THROUGH 32, INCLUSIVE, IN BLOCK 6 OF "RIVERTON ". A REPLAT OF RIVERSIDE TRACTS, AS PER PLAT RECORDED IN VOLUME 13 OF PLATS, PAGE 36, RECORDS KING COUNTY: WITH THAT PORTION OF VACATED 34TH AVE. S. VACATED BY ORDINANCE NO. ON OCTOBER 10, 1988 LYING BETWEEN SAID BLOCKS 5 AND 6: WITH THAT PORTION OF THE SOUTH 1/2 OF VACATED SOUTH 124TH STREET, PORTION OF THE NORTH 1/2 OF VACATED SOUTH 125TH STREET AND THAT PORTION THE EAST 1/2 OF VACATED 34TH AVENUE SOUTH WHICH, PURSUANT TO KING COUNTY NO. 8893, ATTACH TO SAID PARCEL BY OPERATION OF LAW: • THEREFROM THAT PORTION OF LOTS 1 AND 2 IN BLOCK 5 OF "RIVERTON ", REPLAT OF PART OF RIVERSIDE INTERURBAN TRACTS, AS PER PLAT RECORDED IN 13 OF PLATS, PAGE 36, RECORDS OF KING COUNTY, LYING WESTERLY OF A DESCRIBED AS FOLLOWS: A A POINT ON THE WESTERLY BOUNDRY OF SAID LOTS 1 AND 2, SAID POINT 100 FEET DISTANT SOUTHERLY FROM THE NORTHWEST CORNER OF SAID LOT 1; NORTHEASTERLY TO A POINT ON THE NORTHERLY BOUNDRY OF SAID LOT 1, POINT BEING 30 FEET DISTANT EASTERLY FROM THE NORTHWEST CORNER OF SAID 1 AND THE END OF THIS LINE DESCRIPTION; EXCEPT THE SOUTH 30 FEET OF LOTS 8 AND 25 IN SAID BLOCK 6 CONVEYED KING COUNTY FOR SOUTH 125TH STREET BY DEED RECORDED UNDER RECORDING 8810200800: EXCEPT THE EASTERLY 10 FEET OF LOTS 1 THROUGH 8 IN SAID BLOCK 6, TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING 9203260787: IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. Qrt MOUNTED TO WALL " °""` ° °' ' °" °` °" ` " " "m" EXISTING TO REMAIN (SHOWN SHADED) — LOTS INTERURBAN OF TOGETHER 8689 TOGETHER THAT OF ORDINANCE EXCEPT A VOLUME LINE BEGINNING BEING THENCE SAID WITH BRACKET IN WALL - MOUNTED CABINET FIRE EXTINGUISHERS rj EXISTING TO BE DEMOLISHED (SHOWN DASHED) NEW TYPE OF WORK LOT AND TO NO. AND CONVEYED NO. SITUATE Cr Ur'V APR 14 It ‘, ‘ 0 PERMIT CENTER IA 2011 J: \Projects \Savvis \Caddsawis \S heets \se3_a- 000.dwg 4/7/11 2:59 PM COPYRIGHT 2010 CALLISON 0 O O ti co N CO M F W a 1.. > N Z m to la . 1 v C co 04 en co O T— E -W ca w O I Cr) 1` O U a _ O L Q O O > Q I- .Y O , N a, 12 O— �� :Ci } W N N - CO CO mO 0 L -' O O a�N O a)NN • E Z ° Z O 0 co 0 cn J J J ."I co U ✓ 0 uJ M I- < 0 z W 0 I0 0 N N- . CI) L() M N 41; 1- 0 Lu 0 ISSUED / REVISED DATE PERMIT SET 11- APR -11 GENERAL NOTES A -000 F E C B A 1 2 3 4 5 6 7 8 9 10 ACCESS EASEMENT 60' RECORDED NON BUILDABLE EASEMENT 3411 S. 120TH PL. BUILDING 1 98,564 S.F. PARK OCCUPA \CY F SWITCH PARKING 1/1000 =99 GEAR V —N SPRINKLERED BLDG. #1 SWITCH GEAR 1111111111 \ \ \ \ \ \ \\ 11111111 1111111/ ADJUSTED LOT LINE 39,405 S.F. BUIL3I \G 3 161,445 S.F. OCCUPA \CY F PARKING 1/1000 =161 V —N SPRINKLERED 35,080 S.F. YARD AREA BLDG. #3 SWITCH GEAR 24,840 S.F. 24,840 S.F. YARD AREA 18,640 S.F. 18,640 S.F. OPTION YARD W/ NEW FIRE WALL BLDG. #3 SWITCH GEAR BUILDING 4 115,895 S.F. OCCUPA \CY F PARKING 1/1000 =116 1 V -1 HR SPRINKLERED ENCLOSED DOCK OR PARKING AT ANYTIME BLDG. #4 SWITCH GEAR 60' RECORDED NON BUILDABLE EASEMENT AREA OF WORK e. ■ r ROCKERY co Width) 1 REVIEWED FOR CODE COMPLIANCE , APPROVED MAY 032011 City of Tukwila BUILDINS nivl.Slnno KEY PLAN ciASIrStA APR 142011 PERMIT CENTER re 1— z W 0 et co H W ; -- r >i W 1- W o. ca 0 Q � N 0. et Z 0 N J J 0 0 N E 0 Z o 0= N 0 03 a"). C� 3 Fourth Floor 0 E 0 0 0 C) co •> N > CD RI H N co co rn 0 u) I& 0 0 ti co coo CD 0 u) rn N CO N CO 0 N 0 W 2 U Q W U cn cr)� =w° 0. N W W F- 0 ca W Z co co co 0 N 1- 0 u-I 0 ISSUED / REVISED DATE PERMIT SET 11- APR -11 J: \Projects \Savvis \Caddsavvis \S heets \se3_a- 001.dwg 4/7/11 2:59 PM COPYRIGHT © 2010 CALLISON SITE PLAN A -001 1 2 3 4 5 6 7 8 9 10 =MOM UP 1111111MMII 1; w OV STAIR 113 DN. • K VESTIBU E PHASE 5 PHASE 2 6 6 8 41 1 7 1•1•1 •1■1e1 , ■ 1■ I. I■ I■ 1■ 1 ■1 ■1 ■1 ■1 ■I4I ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1111 ■1 ■11111 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 • SECURITY • I EQUIP 331 1 • ■ 1•I•I•Ir MEN 0 • VInd- �,L EN PMM 2B2 -1 10— 11— 0 ®m HALLWAY 'MM 2A2 -1 PMM 2B2 -3 9 10— OH 6 COMMON PATH OF TRAVEL 31' G - H TOTAL DISTANCE TRAVELLED 38' G - E 1■ 1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1 ■1■ ■ I■■ I■■ I■■ I■■ I■■ I■■■ I■ I■■■■ I■■ I ■I ■I ■i ■I ■I ■1■11.1.1.1.1.1�1.1.1 .1.1.1..1.1.1.1.1.1.1.1.1.1.1.1 1.1.1.1.1.1.1.1 ■I.I.I.I.I. k 6 6 6 6 6 V E 6 7— — 7 7 R 7 7 - 7r 7 " 7 1-01 7- ■ PMM 283 -1 PMM 201 -1 PMM 2D1 -2 1 PMM 2B3 -2 PMM 2B3 -3 PMM D AREA OF WORK • • • • ■ • N . • • 8 — -f 8 — 8 8 — 1 1---■ 8 -- ■ • • • • • • • • • • • • • 9 9 -IN 9 — 9 -FE 9 — -- 9 — 1 1-!-! 9 • EGRESS PATHWAYY AND LIGHTING TOTAL DISTANCE TRAV LLED Hill 1111. �` u■■■ E PMM 2A2 -3 FEC X X X DN. PMM 2B2 -2 EXIT I OCCUPANT LOAD. 59 REQ. EXIT DOOR WIDTH (59 X .2 ") = 11.8" PROVIDED EXIT OOR WIDTH = 32.75 ". PROVIDED STAIR WIDTH = 48" Y 9— AN— 9 EGRESS PATHWAYY AND LIGHTING X Q MPOE m Q 17 184' D - E 0 8 Vrd X X X X X M MI y RA S O E`. 10— 0 10— EGRESS PATHWAYY AND LIGHTING PMM 2A2 -4 11— A}— 11— PMM 2DI2 -4 PMM 2C2 -4 LIY PMM 282 -4 X Y 10— TOTAL DISTANCE TRAVELL 305'A- F PMM 2C2 -1 PMM 2D2 -1 Q E TOTAL DI TANCE TRAVELLED 270' - - E 10— PMM 2C2 -2 PMM 2D2 -2 A X ■ I■ I■ I■ I■ I■ I■ I■ I■ I■ I■ I■ I■ I ■I ■I ■I ■I ■I ■I ■I ■I ■I ■I ■I ■I ■I ■I■ • I •I •I •I •I •1 •I ■1 ■I ■I ■I ■I 12— • I •I •I•I •I ■I ■I ■I ■I ■I •I •I •I ■I 12— 13— --A- 13— 14— 15— 14— 15— I •I •I •I •I •I •I •I •I •1 I •I •I •I •I •I •I •I •I •I •1 •I •I •I y 4 J. 705 c a 12— 12 12 12 12 0 X 12 WEI ERE NMI 13— 4-- 13— 14 0 14 15— — 15— 13— 14— tin�115— Q Q 154- 14— 0 PMM 1D2 -1 10— F -1 30.750 103 1 300 3 PMM 2C2 -3 PMM 2D2 -3 E E X 907 1 100 12 -�] 13- o 15— 15— 14 --g1 15— 12 14 T T k X 2 ■I■I ■I■I ■1�1 ■I■I ■I ■I ■I ■I■ 12 0 12— 6 7 8 9 COMMON PATH OF TRAVEL 50'A -B TOTAL DISTANCE TRAVELLED 193'A -C 10— 10— N ▪ L a 13— —RI— 13— 14 N 15— n 1,t 1r' DN STAIR A 1 11 12— 12— 13— 14— 4-1 14 Illlllllll�lml� � - 1A1111CI•III■ EXIT OCCUPANT LOAD: 59 REQ. EXIT DOOR WIDTH (59 X .2 ") = 11.8" PROVIDED EXIT DOOR WIDTH = 32.75" PROVIDED STAIR WIDTH = 48" IV 13— 14— 6 7 13 �- 15— 15— PARTIAL THIRD FLOOR PLAN EGRESS PLAN Hear 0 3 eon REVIEWED FOR CODE COMPLIANCE APPROVED NiAr 0 3 2011 City of Tukwila BUILDING DIVISION FIRE /LIFE SAFETY LEGEND A 3962 14 300 1 CPT =90' TD =180' MEANS OF EGRESS FE 9 ®E OCCUPANCY FLOOR AREA (SF) OCCUPANT LOAD FACTOR OCCUPANT LOAD NUMBER OF REQUIRED EXITS COMMON PATH OF TRAVEL (WIT BISTANCE INDICATED) PATH OF EGRESS TRAVEL TRAVEL DISTANCE (WITH INSTANCE INDICATED) A TO C OCCUPANT LOAD AT EXIT EXIT DOORWAY DATE INDIVIDUAL SPACE. DIRECTION OCUAN EGRESS PER OCCUPANT FROM TABLE 1004.1.1: THE OCCUPANT LOAD FACTOR IS 300 SF /OCC FOR ALL SPACES EXCEPT FOR OFFICE AREAS, WHICH ARE 100 SF /OCC. EGRESS WIDTH FROM TABLE 1005.1 = OCC LOAD X 0.2 FOR STAIRS: OCC LOAD X 0.3 COMMON PATH OF TRAVEL FROM PAR. 1014.3: NOT MORE THAN 100' -0? MAXIMUM TRAVEL DISTANCE TO EXIT ALLOWED FROM TABLE 1016.1: 300'. CORRIDOR WIDTH REQUIRED: 44" MIN. CORRIDOR WIDTH PROVIDED: 8' IN DATA CENTER AREA OF WORK EXIT SIGNAGE FIRE EXTINGUISHER CUMULATIVE OCCUPANT LOAD AT EXIT EXIT SIGN WITH DIRECTIONAL INDICATOR EXIT SIGN - EXISTING SPECIAL FIRE RATING REQUIREMENTS 1. ONE HOUR FIRE RATING FOR ELECTRICAL ROOMS. 2. ONE HOUR FIRE RATING FOR GENERATOR ROOM -CODE MET WITH UL -2085 FUEL TANK, 3. ONE HOUR FIRE RATING AROUND DATA HALLS PER OWNER'S INSURANCE REQUIREMENT, NOT A CODE REQUIREMENT. 4. FIRE PROTECTION SYSTEMS AND DRAWINGS WILL BE SUBMITTED UNDER SEPARATE COVER. KEY PLAN C YRER''' LA APR 14znil PERMIT CENTER Ice W LIU z V CO r, fs CALLISON O N N www.callison.com 1. O 0 LL 1 0 LL 0 0 O N- CO O T- 01 H N Lf� CO ED CO CD ott 3 ca a) 0 0 ti co E 0 0 N > co r LO rn rn 0 U r N Q CO CO ID N N CID CD O O N N 3 F-u.3 M W (.0 0 2 U I— Q 0 Z W 0 0 Oo C0 rn Q o� cts c LO • M M ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\ProjectstSavvis\Caddsavvis\Sheets\se3_a-002.dwg 4/7/11 2:59 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR LIFE SAFETY PLAN A -002 F 8 1 2 3 4 5 6 7 8 9 10 7J- 7— 8 J-4 i e 7 r, 7 7 7 7 o 7 —M 7 M 7 7 —M 8 C. 7 7 J I r 7 7 7 7 n 2'— If 7 'J II ..====4,T.:7==.= t:,:.- rr:._- :.._._..__c..... ..7=7.17.======. :.:.::.J1 ........... PARTIAL SECOND FLOOR DEMOLITION PLAN 1/4 " =1' DEMO STORAGE ROOM WALLS AND DOOR. RETURN DOOR TO OWNER STOCK. DEMO WALLS AS SHOWN (WALLS FULL HEIGHT). DEMO DOORS AND RETURN TO OWNER STOCK. DEMO ALL MILLWORK AND PLUMBING IN ROOM. DEMO ALL ELECTRICAL IN ROOM. DEMO RCP AND HARD LID AS REQUIRED. ? REVI8WED FOR CODE COMPLIANCE 1 APPROVED MAY 032011 Cityof Tukwila BUILDING noFVIgI nI KEY PLAN CITYISR ' LA APR 14 2011 PERMIT CENTER 0 0 0 co N co M H W H > N Z m Ln W 0 • c ca 0 - E 1-W ca 00`�a a) ti a) U 4F, 3 - '5 a a) a) C o N o 1 LL 00� '.WH 0 NN i W d. � :; (0 (0 moo - X00 N N Vi d LL cJ) F- LL • CALLISON www.callison.com N 1- 0 w 0 a ISSUED / REVISED DATE PERMIT SET 11 -APR -11 JAProjects\Savvis\Caddsavvis\Sheets\se3_a-003.dwg 4/7/11 2:59 PM COPYRIGHT © 2010 CALLISON PARTIAL SECOND FLOOR BREAKROOM DEMOLITION A -003 F E B 1 2 3 4 5 6 7 8 10 ( SECURITY FQUP �rrrrrrr�. - uIlIllin 1111111111111111 i\ L_ in { MPOE EIS o E1 19— (TYP. OF ALL) 9 SMPX £ —LOZ VlWd Vtd 9 IL i Y —H rYi t1, 10 -- `.. -. 10 ----- \/ I. /N (TYP. OF ALL) \ 1i A .I N 10 10-- { 1 PMM 283 -3 co PMM 2D1 -2 PMM 2B3 -1 —�a— s-E) FI — is f L —ZDZ VVYYd PMMs Td BE RELOCATED AS PART OF ELECTRICAL. (TYP. OF ALL) 11 —EC- I I T 0 II \ al. a� ati_ m a2 I at a •t 7 8— 8— 9 — 9 �y 10— -- - PARTIAL THIRD FLOOR PLAN DEMOLITION PLAN 1 /16 " =1' i R VE IEWED CODE COMPLIA NCE R APPROVED MAY O32 BUILDING Tukwila UILDING niIncinto DEMO STORAGE ROOM IN BREAKROOM. RETURN DOOR TO OWNER STOCK OR AS DIRECTED. DEMO ELECTRICAL PANELS IN STORAGE ROOM. RE -FEED AS REQUIRED FROM TEMP OR PERMANENT SOURCE. DEMO FULL HEIGHT WALLS IN CORRIDOR. SEE DIMENSIONS FOR AREA OF WORK DEMO DOOR IN CORRIDOR. DOOR TO BE RELOCATED. DEMO ALL MILLWORK AND PLUMBING IN BREAKROOM. DEMO HARDWALLS AND DOOR(S) ADJACENT TO MPOE AS SHOWN. RETURN DOORS TO OWNER STOCK. DEMO SOUTHEAST ENTRY DOOR, HARDWARE AND ELECTRICAL AS NEEDED. DEMO FLOORING IN NEW PMM LOCATIONS. CONFIRM WITH ELECTRICAL CONTRACTOR. DEMO CAGING IF /AS DIRECTED BY OWNER. RETURN TO OWNER STOCK. DEMO EQUIPMENT RACKS IF /AS DIRECTED BY OWNER. RETURN TO OWNER STOCK. KEY PLAN CITlOF1U APR 1 201 PERRUITCEidTER 1 LA 0 M >- o <2 YA 0 E O 0 n> >os o Cts > < 3 Q �o M 1- W -a H > N Z m Lo W ▪ . o ▪ co c o 0 F-W 0 o O _ _ i • 0) ti co U 4 1 < >. CI re ▪ O r- N (1) • Li- CO CO In ', W I__ a. N N ft W d - - - CD to w o0 O0 Loo a I N O N v) o. • LL u) I- 1711. • E Z ° Z o O 0 c N N J J = J J a a� ✓ � 3 W U J 0 H U w 0 a ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\ Projects \Savvis \Caddsawis \Sheets \se3_a- 004.dwg 4/7/11 2:59 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR DEMOLITION PLAN A -004 F B A 2 3 4 5 6 7 8 9 10 14— 15— 5 u C., 1 / 1 I rR U a{. ....i I i i 1 t.` _:.a.. I it \ 1 1 N 4 11! T vis 315 15— 15— 1 5 14— 14 15— 15— 16 — 16 DEMO OFFICE AS SHOWN. REMOVE ALL ELECTRICAL AS DIRECTED. RETURN DOOR TO OWNER STOCK. PARTIAL THIRD FLOOR PLAN LOBBY DEMOLITION PLAN X11 1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 032011 City of Tukwila BUILDINA nninnro KEY PLAN CITYOFTUKNAIA APR 14 2011 PERMIT CENTER 0 M >-o Q • >, o E r2[,: o 0 < c o o 0 r - • - (n (j)U N > >0 CO (0 > > : c a �O M 3 N N- F- F- LC W 1- > N Z m to W ▪ co c a .c9 co - E 4 F- W c0 � • 3 8Q00°' O I- 1- CN C A LL CO 00 .O >. W E— N N cc W CL r -c — CO CO U7 moo '- "-' o o ?� N N N1 0. LL U) F■ ILL 3 ;_. z 0 co 1 V CALLISON www.callison.com o. W co , co 1— u) • w a w M I— W < co 0 ff- Z w 0 J 0 N 1- 0 w 0 a. ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\ Projects \Savvis \Caddsawis \Sheets \se3_a- 005.dwg 4/7/11 2:59 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR LOBBY DEMOLITION PLAN (OPTIONAL) A -005 F E B A 2 3 4 5 6 7 8 9 10 \ \1 7 7 7 7 7 - 7 ' , i ) i' / a ri ii I -1 ' ......................r t....- .... -... 0 BREAKROOM fi CO LC ) C) NEW SINK a Do 00 11" B I 1 I a 11' CONFERENCE 219A ff 7 r 8 8 PARTIAL SECOND FLOOR PLAN 01� BREAKROOM 1/4"=1' i pVEEWE CODE CpMIP FOR IANCE A PPRO L QED MAY 03ail CyotTukwila BD►LDINn nongtnni KEY PLAN aTifISH LA APR 14 2011 PERMIT CENTER O M O V +' O E IWm co — - Lo0 _ � N- > o < °° rn .x O��N CO CO � >W I- 0 N N 0. L co co C.17 000o L o0 3 Ct c\1 N N V� OL tL v) I— IL • www.callison.com M W W W z w U J 0 0 N T- V) 10 M M T N 1- U w 0 0 ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\ Projects \Savvis \Caddsawis \Sheets \se3_a- 102.dwg 4/7/11 3:04 PM COPYRIGHT © 2010 CALLISON PARTIAL SECOND FLOOR BREAKROOM PLAN A -102 F E D B A 1 2 3 4 5 6 7 8 9 1U 7 — 7 8 — 7 7 7— 7 — 7 — 7 —M 7 1CI11af --Lm. STORAGE 332A CfSR) FD" 1i rte ®FD 7 7 7 7 ®FD 10 0 wFD 7 7 7 7 7 FEC BREAKROOM 330 O 00 4' -0" DEMISING WALL WITH ALNUT CAP. -3 5/8" 8 8 — 8 PV N 2B2— 8 — P v Fv 2A2— 8 — FEC EW SINK (cl1I FEC FEC -11" cI1 4'�; C 1 a 2' 15' - ff Pv4N 2A2 -2 PMV 2B2 -2 PARTIAL THIRD FLOOR PLAN BREAKROOM PLAN 1/4 " =1' 1 REVIEWED F OR CODE COMPLIANCE t APPROVED MAY 032011 CityofTukwila BUILDING DIVISION KEY PLAN R CC�� jV TU CITYAF Lai► APR 14 2011 PERMIT CENTER cg W -a > z 0° W v • Fourth Floor 0 0 0 ti co N CD d' N CO CD CO O) Cu m N www.savvis.com 0 r- E 0 Lo N- CA U CO 0 N CU co CO ID N N t0 CD CD 0 0 N N 0 2 < W th1— a� • w 0. w M I— W < N OC w Z w U J 0_ co CO 00 rn N 1— 0 w 0 a ISSUED / REVISED DATE PERMIT SET 11- APR -11 J: \Projects \Sawis \Caddsawis \Sheets \se3_a- 103.dwg 4/11/11 3:20 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR BREAKROOM A-103 F B 2 3 4 5 6 7 8 9 10 7 7 L 11— 11— 12— 12— 9 — 9 10— K PMM 2B2 -3 7 _ —SEE A -103 FOR ENLARGED PLAN \ \ y 9 PMM 2A2 -2 PMM 2B2 -2 RAISED FL. 9 EXIST. AIR SHAFTS (TYP. OF ALL) FEC \/ I 11 XIST. PMMs PMM 2A2 -4 9 1 0--- 7 7 7 7 PMM 2B3 -1 PMM 2D1 -1 PMM 2D1 -2 8 EXIST. PMMs I(NEW LOCATIONS) (TYP. OF ALL) 8... FEC 'I H A` IN II 11— 11— 11_% PJ/ 1 i I I/ l (NEW LOCATIONS) (TYP. OF ALL) PMM 2D2 -4 PMM 2C2 -4 PMM 2B2 -4 12— 4 12— r1 3i 12— 7 12— 12 A. PMM 2C2 -1 a EXIST. PMMs (NEW LOCATIONS) (TYP. OF ALL) PMM 2D2 -1 12 PMM 2C2 -2 PMM 2D2 -2 '9112— 12— PMM 283 -2 PMM 2B3 -3 PMM 2.D1 -3 8 vitWED FOR ODE COMPLIANCE "''ROVED .1 03 2011 ay of Tukwila it 41' rIM( DIVISION 711 �---- 9 10— `/i T SEE A -105 ENLARGED P T PMM 2C2 -3 2D2 -3 Lt r -F� U 1 /A V U 12— — T ='2 r Ibl 2 12-- 0-- PARTIAL THIRD FLOOR PLAN 3/32 " =1' KEY PLAN CITY FTUKiMLA APR 14 2011 PERMIT CENTER W a W _m avO W ~ �G >. W I— CO ILI 0 0 aw vi d • E Z ° Z c) O 0 c N c J J J a w a U t 3 r N r l CO Co r O r E co O L, O L O ~ O U O Q co o) O > r N U u_ co co .n N N co co L - *-' O O O N • • N N u-c 1"1 Li. 3 v/ d, W 2 U o0 Q Q CO J W U CO v) aQ Q = w 0. N CU M 1- W Q Ct W Cr) - co Z MNIMM PROJECT #211 ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\ Projects \Savvis \Caddsavvis \Sheets \se3_a- 104.dwg 4/7/11 3:00 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR PLAN A -104 1 2 3 4 5 6 7 8 9 10 29'-10" c 1 OFFICE 335A OFFICE , B 1 1 1 a 335B 4'-8 3/8" 4'-3 5/ c I 1 10— 10— CE_ _L 10— 10— 10— FEC B I 1 0 -10 5/8" I / V NOC/SOC 335 NOTE: DOORS 319A-C BALLISTIC RATED (BR3). B I 1 BALLISTIC RATED GLASS RELOCATED FROM PREVIOUS SECURITY LOCATION. PASS-THRU PORT 15'-11 3/8" 9'-5 1/4" STAINLESS LEDGE RELOCATED FROM PREVIOUS LOCATION. 11 10- 11— 11— A I 01 PARTIAL THIRD FLOOR PLAN NOC/SOC PLAN 1/4"=1' I 15 L. 5^- --1=============-::=' --r T —1 T 1 15— c I 1 317 CONFERENCE ROOM 318 15— 15— OPTIONAL OFFICE/CONF 317 15— 15— REVIEWEb FOR CODE COMPLIANCE , APPROVED MAY o 3 2011 City of Tukwila BUILDING DIVIRION PARTIAL THIRD FLOOR PLAN LOBBY PLAN (OPTIONAL) 1/4"=1' KEY PLAN CIA% LA APR. 142011 PERMIT CENTER 0 >-o < • >, 0 0 0 < o c)u; °-h o .>— cn c'w (\.1 > > (CI (0 > c c0 • ct ▪ wg IP E Z 0 zo 0 Oc cn wo = co 49 u 3 3 C\▪ J N-- 00 CO 00 1. O < O > —U_ _C ya O a) O"") N. c 03 0) T- CV 0 c0 00 .0 C\J co 00 C C\1 = 1M = CN 1- uJ 0 CC 0- ISSUED / REVISED DATE PERMIT SET 11 -AP R-1 1 J:\Projects\SavvistCaddsavvis\Sheets\se3_a-105.dwg 4/7/11 3:00 PM COPYRIGHT 0 2010 CALLISON PARTIAL THIRD FLOOR ENLARGED PLANS A-105 F B 1 2 3 4 5 6 7 8 9 10 — 7 oFD 7 (TYP.) 7 7 7 7 7 7 7 7 7 P CO' -0" A FO :1=1 ===1:=='=1 =====t==='==7,== ts, ^ " 1 7 Y OTHERS 2x2 CEILIk GRID USG HIGHPNRC TILES. SEE CEILING SCHEDULE. 7 7 8— — PARTIAL SECOND FLOOR PLAN RCP PLAN @ BREAKROOM 1/4"=1' i REIAEWED-001 CODE COMPLIANCE e /APPROVED tor 03 &ill City of Tukwila BUILDING nn/ii, KEY PLAN ctinFg AN 14 2011 PERMIT CENTER „01.MA664.1 1 co 1- Cd . ILI V II. > C \ I Z CO 'T-• I.0 E 0 0 (i) IP E Z °, 0 0 c 1 j co •C a u. t) (1) 0_ I-U uJ ° ••• < < ° CO l- og U3 I < uJ- w a. %— < 0). ()OLO ce w co C 1- uJ 0 o_ ISSUED / REVISED DATE PERMIT SET 11-APR-11 JAProjects\Savvis\Caddsavvis\Sheetsise3_a-106.dwg 4/7/11 3:00 PM COPYRIGHT © 2010 CALLISON PARTIAL SECOND FLOOR RCP @ BREAKROOM A-106 (10' - " AR") F B A 1 2 3 4 5 6 7 8 9 10 7 7 7 7 .............. 7- r. II Ii • I i 7 7 7 7 A9 8i (TYP.) ®I1) 7 7 7 7 7 / c PV V 2B2— P V 2A2— r- - IT II 0 ,J N ii N 11 LIGHTING BY OTHERS 2x2 CEILING GRID USG HIGH NRC TILES. SEE CEILING SCHEDULE. 0 f' r........_........._........_ _'___: rs::'_:-:__ rr:'____'_.: c'____:: x _:::::::::::.�x:.r:.::::::: :.xr .._....__.......r. PV V 2A22 8 PV V 2B2 -2 — 01 PARTIAL THIRD FLOOR PLAN RCP @ BREAKROOM 1 /4 " =1' i REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 3 2011 City of Tukwila BUILDING DIVIq, g KEY PLAN cirrOni APR 14 2011 PERMIT CENTER .;1 LA 0 0 O co N M H W a �.. > N Z co W ao v c 0 4 Ch O x- E I-WfII 000`nO _ L o ti 0 O a F ?� O Q o 0 > C . O x- N O LL CO O i'WI- ANN s W 0. 1, }, CO 0 oO 0 0 L "-' 0 0 i a N O O N N �%i 0. LL v) I- II. E Z ° Z 0 0 y N O J J = J J co a� ✓ 3 w M I— W < co 0 w Z w U J 0 CV M CO co co ISSUED / REVISED DATE PERMIT SET 11 -APR -11 J:\ Projects \Savvis \Caddsavvis \Sheets \se3_a- 107.dwg 4/7/11 3:00 PM COPYRIGHT © 2010 CALLISON PARTIAL THIRD FLOOR RCP @ BREAKROOM A-107 F 2 3 4 5 6 7 8 9 10 u 10 I\ \I u LIGHTING BY OTHERS (TYP.) U U 2�N HIG SEE CEIUN c GRID TILE SCHED R S. ULE. 1 / i / i 10— 10— 10— 10— 0-- (1)' -0" A F) L IGHTING BY OTHERS (1 C -0" AFF) (10' -0" AFF) 1t 0 0' -0" AFF) HARD LID 10— 11— PARTIAL THIRD FLOOR PLAN RCP @ NOC /SOC 1 /4 " =1' EXISTING HARD LID V LIGHTING BY OTHERS PARTIAL THIRD FLOOR PLAN RCP @ LOBBY (OPTIONAL) 1 /4 " =1 � EVIEWE p FOR DE COMPLIANa 1 MAY 03 2U/i City of Tukwila KEY PLAN CITYOFTUKIAALA APR 1 ? 2011 PERMIT CENTER >- o >-,p E tY _ O O < c p o o_ = h co O co •- • �r, N > >0 0 cm > > d: v, a u) co 3 0 o •-i- F re W a , 1- > N Z LO W - co ✓ ,. c CO. O T- E i�' W O I w 0 `O o - L I's- O V 0 rn a�oa > p .�c 0 017)C\1(1) rd : LL 00 „p >' w ~ N N N C W a ,r— ▪ _, m m c/1 C 00>_ - 003 Q ig N O (O N N CD Ma,tLW Hu. • E Z O Z U 0 0 c rJ7 co o J J a� ✓ 3 C/) a W 2 U o0 Q Q co '."1r' W a, ao CI) Q � � Q = wog 0. W`� co co) F-- • Q • 0 Lo Lo w M F- M Z 1— 0 w 0 ISSUED / REVISED DATE PERMIT SET 11 -APR -11 J:\ Projects \Savvis \Caddsawis \Sheets \se3_a- 108.dwg 4/7/11 3:00 PM COPYRIGHT ® 2010 CALLISON PARTIAL THIRD FLOOR RCP NOC / LOBBY A -108 1 3 4 5 7 8 9 10 STRUCTURE CEILING (WHERE OCCURS) AT FIRE -RATED CONSTRUCTION EXTEND INSULATION (WHERE OCCURS) FULL HEIGHT PARTITION CONFIGURATION: STRUCTURE CEILING (WHERE CEILING OCCURS) w .ni."""muu".m.m.m.m".""m". "mi..u."m.. loin m.mmm.mnn.nmmi.""."i EXTEND INSULATION FULL (WHERE HEIGHT B PARTITION CONFIGURATION: NEIF CEILING TOP OF WALL EXTEND 6" BEYOND ACP EXTEND INSULATION (WHERE OCCURS) FULL HEIGHT PARTITION CONFIGURATION: FULL - HEIGHT FINISH MATERIALS BOTH SIDES PARTIAL HEIGHT FINISH MATERIALS BOTH SIDES PARTIAL HEIGHT FINISH MATERIALS BOTH SIDES PARTITION/ WALL DESIGNATIONS NO SCALE moot BR3 RATED MATERIALS j AND BR 3 RATED MATERIAL ON OUT FACING SIDE. C t NO INSULATION BATT ACOUSTICAL INSULATION RIGID (THERMAL) INSULATION BATT THERMAL INSULATION PARTITION TYPE- INSULATION INDICATOR NO SCALE C1010FP -03 PARTITION /WALL SYMBOLOGY PARTITION /WALL RATING LEGEND THE PARTITION -TYPE DESIGNATION OR WALL -TYPE DESIGNATION IS A THREE - UNIT CODE THAT INDICATES THE CONFIGURATION, CONSTRUCTION AND INSULATION OF THE PARTITION AS FOLLOWS: INSULATION CONSTRUCTION OF PARTITION /WALL VERTICAL CONFIGURATION OF PARTITION /WALL ►a NON FIRE -RATED 1HR FIRE -RATED PARTITION /WALL NOTES 1. SEE SPECIFICATION SECTION 09111 FOR STUD SPACING AND GAGE. 2. ANY PARTITION CONTAINING ACOUSTICAL INSULATION AND ONLY PARTITIONS CONTAINING ACOUSTICAL INSULATION SHALL BE CONSIDERED ACOUSTICAL PARTITIONS. PARTITION /WALL NOTES NO SCALE C1010FP -0 U d E9 METAL STUDS (PER ES REPORT ESR- 2054), MAXIMUM HEIGHT 20' -0" FINISH MATERIALS VARY (MAXIMUM WEIGHT EQUAL TO 2 LAYERS GYPSUM BOARD EACH SIDE PLUS APPLIED FINISHES) FASTENERS: AT PLYWOOD FLOOR (MINIMUM 3/4" CDX): PROVIDE (2) NO 8 X 1" WOOD SCREWS AT 24" MAXIMUM OC STAGGERED FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" MAXIMIM OC STAGGERED FOR 2 LAYERS GYPSUM BOARD EACH SIDE AT CIP CONCRETE AND POST- TENSIONED CONCRETE FLOOR: PROVIDE HILTI X -U 0.157" DIAMETER POWDER- ACTUATED FASTENERS, EMBED 3/4" PER ESR -2269. 24" MAXIMUM OC STAGGERED FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" MAXIMUM OC STAGGERED FOR 2 LAYERS GYPSUM BOARD EACH SIDE i PTN- TO -FLR CONNECTION FOR SEISMIC SITUATIONS 3 " =1' -0" C1010FP -08 LAST REVISED: 03 -2 ANNOTATION SCALE ADDITIONAL INFORMAT -07 �5/8" GYPSUM BOARD EACH SIDE :IS 5/8" TYPE "X" GYPSUM BOARD EACH SIDE ONEWS ED ITUATIONS. CALCULATIONS ON FILE. METAL STUDS 5/8" GYPSUM BOARD METAL STUDS INSULATION IF NOTED INSULATION IF NOTED INSULATION IF NOTED 1 3 5/8" METAL STUDS 6" METAL STUDS NOT USED PARTITION NO SCALE C1010FP -22 Y J PARTIAL- HEIGHT PARTITION UP TO 10' -0" LONG, BETWEEN PARTIAL - HEIGHT OR FULL - HEIGHT PARTITIONS (EACH AT LEAST 11 -6" LONG) NEED NO SUPPORTS AS LONG AS TOP TRACK IS SPLICED TO ADJACENT PARTITIONS PER DETAIL C > — < II - r (-0" MAX FROM ANY CROSSING PARTITION, OR FROM END OF FULL - HEIGHT PARTITION 4' -0" OC MAX, TYPICAL ALONG PARTITION 1' -6" MAXIMUM FROM END OF PARTITION 4' -0" MAX FROM ANY CROSSING PARTITION, OR FROM END OF i FULL - HEIGHT PARTITION `• — II 1 ("A) J SUPPORT - LOCATION DIAGRAM 4 5 6 3 5/8" METAL STUDS 6" METAL STUDS NOT USED PARTITION (1HR FIRE - RATED) NO SCALE CONSTRUCT PER UL DESIGN NO U419 NOTES: PROVIDE GYPSUM BOARD ON BOTH SIDES OF STUDS 11 4 .1/2" 3/16" X 3 1/2" X 2' -0" PLATE 4 1/2" / <1/2" 1/2 "7 CNI TTOM TRACK BE EATH SUPPORT 3/16" THICK STEEL PLATE 3/16" 3/16" (4 TOTAL) FASTENERS - HILTI KWIK -BOLT 3/8" DIAMETER X 2" EMBED INTO CONCRETE PER ES REPORT ESR -1663. IN POST- TENSIONED CONCRETE, ANCHORS TO BE 4" MIN FROM TENDONS, AS VERIFIED BY X -RAY PRIOR TO DRILLING FOR ANCHORS 0 SUPPORT DETAIL (PLAN VIEW) INA — C1010FP -09 7 2 1/2" METAL STUDS 3 5/8" METAL STUDS 6" METAL STUDS PARTITION NO SCALE C1010FP -21 10 11 METAL STUDS INSULATION IF NOTED 3 5/8" METAL STUDS REVIEWED FOR CO DE COMPLIANCE APPROVED 0 3 2011 City ofTukwila BUILDING DIVISION 4" METAL STUDS 6" METAL STUDS PARTITION NO SCALE C 9 FIRE -RATED GYPSUM BOARD TO OVERLAP 2" MINIMUM ONTO SHAFTWALL SYSTEM 1 HR FIRE -RATED HORIZONTAL SHAFTWALL MEMBRANE CONSTRUCTED PER ES REPORT NER -258. HEIGHT PER CEILING PLANS FIRE -RATED METAL STUD PARTITION PER FLOOR PLANS CORRIDOR 1HR RATED PARTITION AT CEILING NO SCALE C1010FP -39 Tpp iN � T qO'°p�F ` -S p �TppT g�p Sp0 Cq Sp� F N, tip s MiSeT 0 M (AB70i -c4/ T F es gccF�F� FS�S4 p� � /64)6,3)4, %.. 412¢,.4 0 PARTITION- FRAMING DETAIL SUPPORTS REQUIRED FOR PARTIAL - HEIGHT PARTITIONS USING 3 5/8" STUDS (UP TO 5' -6" AF 3 " =1' -0" C1010FP -04 CONCRETE SLAB OR FLUTED STEEL ROOF DECK OR FIRE -RATED FLUTED STEEL FLOOR DECK (ORIENTATION OF PARTITION WITH RESPECT TO DECK FLUTES MAY VARY) FILL VOID WITH PACKING MATERIALS IF REQUIRED BY UL DESIGN C9N 1�z boo a CC CZ CZ = po O CL .ct CC T CD J W a3a Aeons A 0 CC OPARTITIONS TYPICAL PARTITION i LOCATED WITHIN DECK SPAN (PARTITION FOR 1HR, 2HR AND 3HR FIRE RATINGS, CONSTRUCT PER UL DESIGN HW -D -0060 FOR 1HR, 2HR AND 3HR FIRE RATINGS, CONSTRUCT PER UL DESIGN HW -D -0119 HW -D -0120 11 SHAFTWALL PARTITION INDICATED PARALLEL TO DECK FLUTES) CONCRETE SLAB OR FLUTED STEEL ROOF DECK OR FIRE -RATED FLUTED STEEL FLOOR DECK // A ro. AW CI VIEW OF PARTITION WHEN CONSTRUCTED CD tom. O PERPENDICULAR TO DECK FLUTES A5 JOINT BETWEEN FIRE -RATED FRAMED PARTITIONS I& STRUCTURE ABOVE HOURLY FIRE - RATING OF THE FLOOR ASSEMBLY MUST BE EQUAL TO OR GREATER THAN THE RATING OF THE PARTITION CITMJI ' , LA APR 14 2011 PERMIT CENTER N 4 co W z 4 co H W a- O I re >- W w la GOO a� CO d • Z 0 N 1 J 0 CO 0 N N O LL 0 0 0 co N c0 M 1• E 0 0 N ca 3 0 — E o lf) a N- o U c0 M� N M M co co N N W 0• 03 N N I- LL W o. C) W C/) 0_ W 2 U Q Q a_ Q UJ N uJ f— Q (/) O LO ELI CY) M z ISSUED / REVISED DATE PERMIT SET 11- APR -11 J:\Projects\Savvis\Caddsavvis\Sheets\e3_a-80Clidwg 4/7/11 3:00 PM COPYRIGHT © 2010 CALLISON DETAILS A -800 1 2 3 4 5 6 7 8 9 10 3/4" CLEAR AT ONE END IN EACH DIRECTION. DO NOT FASTEN THIS END TO THE CLOSURE ANGLE. AT OTHER END IN EACH DIRECTION, FASTEN TEES TO CLOSURE ANGLE. HANGAR WIRE AT EACH PERIMETER MAIN TEE AND rr PERIMETER CROSS TEE STABILIZER BAR TO MAINTAIN PERIMETER TEE SPACING MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM) HEAVY DUTY 8" MAX 2 X 2 CLOSURE ANGLE, MINIMUM. SEE NOTE AT TOP. OPERIMETER SUPPORT NOT REQUIRED IN SEISMIC DESIGN CATAGORY C FOR CEILINGS LESS THAN 144 SF FASTEN TO STRUCTURE PER CISCA 3 -4 (FIGURES 2, 3, 4, AND 5) AS MODIFIED BY ASCE 7 -05. SECTION 13.5.6.2.2 12 GAGE MINIMUM HANGAR WIRES AT 4' -0" OC EACH DIRECTION - NO MORE THAN 1:6 OUT -OF- PLUMB, TYPICAL WIRE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM AT EACH END OF HANGAR WIRE WITHIN A 3" MAXIMUM LENGTH © GENERAL SUPPORT EXCEPT AS INDICATED IN DETAILS C AND F, COMPONENTS OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SHALL BE INDEPENDENTLY SUPPORTED AND BRACED FROM STRUCTURE WHERE HANGAR WIRES ARE MORE THAN 1:6 OUT -OF- PLUMB, PROVIDE COUNTER - SLOPING WIRES METAL - FRAMED TRAPEZE AS NECESSARY TO AVOID OBSTRUCTIONS MAINTAIN HANGAR WIRE SPACING AND CAPACITY BELOW OBSTRUCTION 00 ACOUSTICAL CEILING PANELS COMPLY WITH ADDITIONAL PROVISIONS OF ASTM C635, ASTM C636, CISCA 3 -4, AND ASCE 7 -05, SECTION 13.5.6. 1 1 LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (1) 12 GAGE TAUT OR SLACK WIRE LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS, AND AIR TERMINALS /SERVICES WEIGHING MORE THAN 20 POUNDS AND LESS THAN 56 POUNDS SHALL BE CONNECTED TO STRUCTURE ABOVE BY (2) 12 GAGE TAUT OR SLACK WIRES ATTACHED AT DIAGONAL CORNERS LIGHT FIXTURES AND AIR TERMINALS /SERVICES WEIGHING MORE THAN 56 POUNDS AND ALL PENDANT LIGHT FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING APPROVED HANGARS LIGHT FIXTURES, AIR TERMINALS, AND SERVICES SHALL BE POSITIVELY ATTACHED TO THE CEILING SYSTEM © LIGHT FIXTURE AND MECHANICAL SERVICE SUPPORT FOUR 12 GAGE MINIMUM WIRES SPLAYED 90 DEGREES ON PLAN) FROM EACH OTHER AND SECURED TO MAIN RUNNER WITHIN 2" OF INTERSECTION. EACH END OF EACH WIRE TO BE LOOPED AND WRAPPED AROUND ITSELF 3 TIMES MINIMUM WITHIN A 3" MAX LENGTH )1 LOCATE BRACING AT 12' -0" OC EACH DIRECTION AND WITHIN 6' -0" OF PERIMETER WALLS, PARTITIONS, OR EXPANSION JOINTS FOR SPANS UP TO 6' -0 ", USE A SINGLE 20 GAGE 1 5/8" COMPRESSION STRUT FASTENED TO MAIN TEE WITH (2) NO 8 SCREWS AND TO STRUCTURE WITH (2) HILTI X -DNI .145 DIA X 3/4" J FOR SPANS UP TO 9' -0 ", USE DOUBLE COMPRESSION STRUT OLATERAL BRACING FOR CEILINGS EXCEEDING 144 SF CONTRACTOR OPTION FOR CATEGORY C: PROVIDE ALTERNATIVE LATERAL BRACING DESIGN BASED ON ASCE 7 SECTION 13.3.1 AND 13.5.6.1 CI INSTALLATION Of SUSPENDED ACOUSTICAL CEILING SYSTEMS - 2006/2009 IBC SEISMIC DESIGN CATEGORY C, D, E, AND F NO SCALE PROVIDE CEILING EXPANSION JOINTS AS NECESSARY, DIVIDING CEILING INTO AREAS NO GREATER THAN 2500 SF 8" MAX EACH SIDE SEISMIC DESIGN CATEGORY C: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 3/8" IN ALL HORIZONTAL DIRECTIONS SEISMIC DESIGN CATEGORY D, E, ANF F: PROVIDE FLEXIBLE CONNECTION TO SPRINKLER HEAD THAT ALLOWS CEILING TO MOVE 1" IN ALL HORIZONTAL DIRECTIONS OEXPANSION JOINT FOR CEILINGS EXCEEDING 2500 SF NOT REQUIRED IN SEISMIC DESIGN CATEGORY C nl� OSPRINKLER HEAD CLEARANCE C3030AC -01 ww U °oCC Li" C_) W Cr) J J CC U FQU- 5 ▪ CL I.L.1N w CC O WALL END OR EDGE (WHERE OCCURS) DOOR FRAME OR WINDOW FRAME 1 1 /I V 11 " 1 FIRE ALARM THERMOSTAT OR TEMPERATURE SENSOR I 'Uo _J 0 °° v--- TELEPHONES,. DOOR SWITCHES, DOOR " DEVICE MOUNTING GUIDELINES CONTROLLERS, FIRE ALARM PULL SWITCHES, LIGHT SWITCHES AND SIMILAR ITEMS (THE INTENT IS TO ALIGN TOPS OF ALL ITEMS WHILE ALLOWING ALL OPERABLE PARTS TO BE LESS THAN 4' -0" AFF) ELECTRICAL RECEPTACLES - SINGLE, GANGED, OR SEPARATED BY 2" aco NOTES: 1. USE THIS DETAIL TO LOCATE DEVICES THAT ARE INDICATED ON THE DRAWINGS BUT NOT LOCATED BY DIMENSION, OR TO LOCATE REQUIRED DEVICES THAT ARE NOT INDICATED ON THE DRAWING. 2. ALIGN MULTIPLE DEVICES HORIZONTALLY AND /OR VERTICALLY AS DETAILED. 3. ITEMS OTHER THAN ELECTRICAL RECEPTACLES SHALL BE MOUNTED NEAR DOORWAYS OR INTERSECTING WALLS AS DETAILED SO AS NOT TO INTERFERE WITH THE PLACEMENT OF ART OR FURNITURE - - EXCEPT THAT WHERE THE WALL SEGMENT IS LESS THAN 24 9/32 WIDE, CENTER THE DEVICES AS DETAILED. 1 1 k------WALL END OR EDGE 1 (WHERE OCCURS) WALL SEGMENT 24" WIDE OR LESS EQUAL 1, EQUAL WINDOW, i DOR OR "FEATURE" THAT SEPARATE WALL INTO SEG ENTS 1/2"= 1' -0" H30 -01 REVIEWED FOR CODE COMPLIANCE .1 IN POROVED tN`ii;1 0 3 2011 City of Tukwila BUILDING NANIN1fN SQUARE -EDGED PANEL, WHERE OCCURS ACOUSTICAL CEILING PANEL MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM) EXPANSION JOINT T11 1 x" SEISMIC/EXPANSION JOINT IN SUSPENDED ACP SYSTEM 6 " =1' -0" C3030AC -10 SQUARE -EDGED PANEL, WHERE OCCURS ACOUSTICAL CEILING PANEL MAIN TEE OR CROSS TEE (SUSPENSION SYSTEM) EXPANSION JOINT AS SPEC'D SEISMIC/EXPANSION JOINT IN SUSPENDED ACP SYSTEM 6 " =1' -0" C3030AC -11 '0114)90 CIYY b hi'{� LA APR 14 2011 PERMIT CENTER N a N rd W Z Lu ✓ a (1) () CS) (') n LLI Of U W La oo Of et Z O N 1 J u r- 0 N N E 0 Z c, O c co N 0 ▪ = J ca a() ✓ 3 L 0 LL L 0 LL 0 0 0 N- CO N 0 M H 0 `— E 0 Ln N- O) CO Cr) r N O CO CO I: N N W CO CO 003 N N I-I W en 0. co) W w U o0 < J r- 0_ Co Q o co CO I- M F- U w 0 ISSUED / REVISED DATE PERMIT SET 11 -APR -11 J: \Projects \Savvis \Caddsawis \S heets\se3_a- 801.dwg 4/7/11 3:00 PM COPYRIGHT © 2010 CALLISON INTERIOR DETAILS A -801