HomeMy WebLinkAboutPermit D11-109 - DINH RESIDENCE - IMPROVEMENTDINH RESIDENCE
11808 44 PL S
Dl 1 -109
City oftukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3347400730
Address: 11808 44 PL S TUKW
Suite No:
Project Name: DINH RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -109
Issue Date: 06/24/2011
Permit Expires On: 12/21/2011
Owner:
Name: DINH LOAN NGOC THI
Address: 11808 44TH PL S , TUKVVILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: CADENCE CONSTRUCTION INC
Address: 5821 S FLETCHER ST , SEATTLE WA 98118
Contractor License No: CADENCI915JB
Phone: 206 - 296 -7437
Phone: 206 - 355 -8340
Expiration Date: 04/05/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS .AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $35,095.10 Fees Collected: $1,239.61
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D11 -109 Printed: 06 -24 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private:
Storm Drainage:
Street Use: Profit: N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
Private:
Public:
Non - Profit: N
Public:
Date: ll2 - -221v "l
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this p rmit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or thelp ormance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit. (� 243 r r
Signature: VL/ \ / Date: °✓ L� ✓ ` \
Print Name: "' M 3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
doc: IBC -7/10
D11-109 Printed: 06 -24 -2011
7: All plumbing and gas piping work shall lopipspected and approved under a separate pet issued by the City of Tukwila
Building Department (206- 431 - 3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -109 Printed: 06 -24 -2011
CITY OF TUKWILA)
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: / /wwrt'.ci. tukwila. wa. us
Building Perm.No. D C t `• C o q
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
O%to, o3, 1 �
Site Address: 11808 44th Place S.
Tenant Name: Loan Ngoc Thi Dinh
Property Owners Name: Loan Ngoc Thi Dinh
Mailing Address: 11808 44th Place S.
King Co Assessor's Tax No.: 3347400730
Suite Number: Floor:
New Tenant: ❑ Yes ® .. No
Seattle
City
WA 98178
State Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name:. SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
H:\Applications \Forms - Applications On Line \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ION — 206- 431 -3670
Valuation of Project (contractor's bid price): $ 367$2e 3) OR 5 • 10 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
• H: Applications'Fonms- Applications On Line•.2009 Applications..1.2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
. Type of
Occupancy per
IBC
1st Floor
2,106
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
• H: Applications'Fonms- Applications On Line•.2009 Applications..1.2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
•
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
•
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE
Signature:
• IR
.it
Print Name: 'r'j Wt 't f Lo j Day Telephone: V,k) (p -
Mailing Address: 11O0O P&1 -YiD W �l.t.( ?�0 W ' etstpro
Q City State Zip
THORIZED AGENT:
Date: ''ZS r 2.o it
Date Application Accepted:
Date Application Expires:
O'YS— cI
Staff Initials: (4AQ
H: Applications \Forms- Applications On Line\2009 Applications\1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
0
C City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
Parcel No.: 3347400730
Address: 11808 44 PL S TUKW
Suite No:
Applicant: DINH RESIDENCE
RECEIPT
Permit Number: D11 -109
Status: PENDING
Applied Date: 04/25/2011
Issue Date:
Receipt No.: R11 -00852
Initials:
User ID:
Payee:
TLS
1670
Payment Amount: $1,239.61
Payment Date: 04/29/2011 08:56 AM
Balance: $0.00
KING COUNTY /PHONE AUTH
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 024034
ACCOUNT ITEM LIST:
Description
1,239.61
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $1,239.61
748.55
486.56
4.50
doc: Receiot -06 Printed: 04 -29 -2011
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: . � ��
if Oh Re- LL&
Type of Inspection:
' kJA IL : t 61.A
i � s: Q �
�
Date,�alled:
- 0 Az-
Special Instructions:
`3. S
(
---(-1(
Date Wante df.'-
5 -. (.5"/ (i
m=
p p.m.
Requester:
Phone No:
��
Approved per applicable codes. Il Corrections required prior to approval.
COMMENTS:
M
� :4 I ( A -f1 d
(inspec or:
(1— . IDateq ((
ri REINSPECTION FEE REQUIRED. rior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. S ite 100. Call to schedule reinspection.
• •
COP
PLAN ' E IEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -109
PROJECT NAME: DINH RESIDENCE
SITE ADDRESS: 11808 44 PL S
X Original Plan Submittal
Response to Correction Letter #
DATE: 04 -29 -11
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: CC", I
Building Division
NU"
Public Works
Zrevention
Structural
►• 0C-47
Planning Division Lalj
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
tst
Incomplete
DUE DATE: 05-03 -11
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route XI Structural Review Required No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05-31 -11
Approved n Approved with Conditions , Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name CADENCE CONSTRUCTION INC UBI No. 602882989
Phone 2063558340 Status Active
Address 5821 S. Fletcher Street License No. CADENCI915JB
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 4/2/2009
State WA Expiration Date 4/5/2013
Zip 98118 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
CADENC'971K2
CADENCE
CONSTRUCTION
Construction
Contractor
General
Unused
5/22/2003
8/9/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
NISSINEU, KIMMO JOACHIM
President
04 /02/2009
Amount
KELLEY, KATIE ANN
Vice President
04/02/2009
CGL000758622
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
& INDEM CO
799434C
03/18/2009
Until Cancelled
$12,000.00
04/02/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
BERKLEY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2010
11/26/2011
$1,000,000.00
11/03/2010
1
BERKELY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2008
11/26/2010
$1,000,000.00
10/27/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx
06/24/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00624C11 BID PACKAGE S -23
5- 53- 0058 -043
FILE COY
Permit No No. slA,
Plan review approval is subject to errors and omissions.
Approval of cons ruction documents does not authorize
thc violation of y adopted code or ordinance. Receipt
of approved F'el opy and conditions is acknowledged:
By. 1
Date :. L`Ylz ll
City Of Tbkwila
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
Gas Piping
City of Tukwila
CI„III„c)ING r"iyi loN
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukvlrila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SITE AND BUILDING INFORMATION
JURISDiCTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
WUashington State Energy Code
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
Y B NON SPRINKLERED
EUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
CODE FOR
E COMPLIANCE
t APPROVED
MAY 10 2011
v
Cf kwila
BUILDIN (VISION
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHEDULE 4 DETAILS
42.1 DOOR TYPES, SCHEDULE 4 DETAILS
42.2 MISCELLANEOUS DETAILS
42.3 WINDOW FLASHING DETAILS
Mi.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DUJG INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
E1.0 ELECTRICAL PLAN
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound insulation Program
King County international Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E- mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. &temper Architects PLL.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmstemper.com
timesmstemper.com
ACOUSTICAL ENGINEER
55A Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
i'h: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Ait Allaoua Contact: Brent Rollins
E -mail: mohamedossaacoustics.com E -mail: bcretreswest.com
ELECTRICAL ENGINEER
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
MECHANICAL ENGINEER
The Greenbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Chris Agar
E -mail: ChrisAsereenbusdncom
REGULATED MATERIALS:
PB& Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162. 4180
Contact: Tim Ogden
E -mail: t1m ogden,bsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North UJashington St. 0200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mall: JCornwelleJonespayne.com
VICINITY MAP
ECEIVED
APR 2 9 2011
PERMIT C NTER
109
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
:COTT i ?: `.i;:i.c i',.
• 4V
0810.03.1741
2/24/11
O
d
J
Z
0
I-
<
Z
w
H
z
z
0
U
Z
MPROVEMENTS
0
w
w
w
0)
O
z
J
Z
w
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1741
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO S:00 All EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING PETALS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM- CLEANED AT NE END OF EACH WORK DAY.
S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHEN SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AUd FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET EI.O FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE S :00 AM. 4 AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOP ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
FAMILY
ROOM
CLOSET
D ININCrt
ROOM
FOYER
NEW 24" x 24"
ATTIC ACCESS,
WATCH
NO INSULATION -- /
REQUIRED
KITCHEN
OFFICE
/ / S
22" x 514"
PULL ITQUN /
STAIR 1 /
-r
it
NO INSU1lATION
REQUIRED'
24" x 24" EXIST.
• ATTIC ACCESS
• IkATCW.
z.
BEDROOM
2
BEDROOM
3
LIVING
ROOM
CLOSET
CLOSET
46' -2"
ATTIC PLAN
NTS
CLOSET
BEDROOM
4
BATI-1 1
BEDROOM
22" x 54"
EXIST. PULL
DOWN STAIR
BAT1 -I 2
^^A
MAIN FLOOR PLAN
1/4" = 1'
NOTE:
I. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
A. SOUTH ELEVATION
B. WEST ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0
0 DEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
l `,J DOOR SCHEDULE ON SHEET A 2J
H EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH
O DEMOLISA
ANIL
MECHC.
0 INSTALL SECONDARY SLIDING GLASS DOOR REF. A2.1 FOR DOOR SCHEDULE
:i INSTALL VENT BAFFLES) AT EXISTING RIDGE VENT(S) IN ATTIC, REF. 4/A22 FOR DETAIL.
OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/422 FOR DETAIL
0 INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
OBLENDING UNIT LOCATED N ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. RP. 2/422 FOR DETAIL.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. NORTH ELEVATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
+ MAY 102011
City of Tukwila
BUILDING DIVISION
22' -3"
H
N
D. EAST ELEVATION
LEGEND
14%-lO
=1--C__„-- ACOUSTICAL WINDOW
X
SECONDARY SLIDING GLASS DOOR
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.0
0 SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
EXISTING KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
VENT BAFFLE
NOT USED
FEATHER TEXTURED CEILING OVER AT A
MN. OF 24" FROM EDGE OF PATCHNG.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE HOUSE VENT INSTALLATION.
REF. MECH. 4 ELECT.
REF. GENERAL NOTE 11
NOT USED
RECEIVE
APR 29 20t
PERMIT CBE
D
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
'�' GAS METER
li• 1 I
w�
R
Nag
S.MSTEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 98100
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1741
2/24/11
0
11.
J
z
0
Q
z
W
z
z
0
U
0
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
z
0
0
LLI
w
C/)
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1741
WINDOW TYPES
SLIDER
2
FIXED
3
SLIDER/ FIXED/
SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
Wx H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
ENTRY
2
I' -S" x 5' -6"
PAINT/PAINT
SAFETY GLAZING REQUIRED
OBSCURE GLASS
1 /A2.0
B
BEDROOM I
I
51 -2" x 4' -5"
PAINT/PAINT
Y
I/A2.0
C
BEDROOM I
1
5' -2" x 4' -5"
PAINT/PAINT
1/A2.0
D
BEDROOM 2
1
5' -2" x 4' -5"
PAINT/PAINT
Y
I /42.0
E
BEDROOM 3
I
5' -2" x 4' -5"
PAINT/PAINT
Y
1/42.0
F
LIVING ROOM
3
6' -6" x 4' -5"
PAINT/PAINT
I /42.0
G
LIVING ROOM
I
3' -6" x 4' -5"
PAINT/PAINT
I /42.0
14
FAMILY ROOM
3
6' -0" x 4' -0"
PAINT/PAINT
I /42.0
I
ENTRY FOYER
I
4' -0" x 2' -10"
PAINT/PAINT
1/42.0
J
OFFICE
I
3' -6" x 2'10"
PAINT/PAINT
I/42.0
K
OFFICE
I
2' -10" x 2' -10"
PAINT/PAINT
1/42.0
L
KITCHEN
I
3' -10" x 2' -I0"
PAINT/PAINT
1/42.0
M
LIVING ROOM
3
6' -1" x 4' -5"
PAINT/PAINT
1/42.0
N
BEDROOM 4
I
5' -2" x 4' -5"
PAINT/PAINT
Y
1/A2.0
0
BEDROOM 4
I
5' -2" x 4' -5"
PAINT/PAINT
I /A2.0
P
ENTRY
2
1' -S" x 5' -6"
PAINT/PAINT
SAFETY GLAZING REQUIRED
OBSCURE GLASS
I /42.0
(E) = EXISTING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 FAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY GUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND FAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) IUD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
WINDOW HEAD
to
sm.
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT /STAIN TO
MATCH (E) TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WINDOW JAMB
(E) GWB
W000 TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
51-IIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SACKER ROD 4
SEALANT
3/S"
3/4" WD. SILL - STAN TO
MATCH (E)
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'0 TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW SILL
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
1 REV MAY J 10 Ep OF 2011
ODE COMPLIANCE
t APPROVED
CODE
City of Tukwila
BUILDING nil/mink,
btl- loq
RECEIVED
APR 2 9 2011
P T C LATER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 621 -2777 • FAX (206) 824 -2973
0810.03.1741
2/24/11
O
a
-J
Z
0
I-
<
z
w
z
z
0
U
0
Z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1741
DOOR TYPES
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
IN SAFETY GLAZING
W/ OBSERVATION PORT
B
FLUSH SCW
W/ SIX PANELS
W/ OBSERVATION PORT
c
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
Wx H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
3' -0" x 6' -S"
STAIN/STAIN
HW -I / 605
DK -I
LOCK -I
1/42.1
2
HALLWAY
B
2' -8" x b' -&"
STAIN/STAIN
HW -1 / 605
DK -I
LOCK -I
1 /A2J
3
DINING ROOM
C
6' -0" x 6' -S"
2 /A2.1
4
FAMILY ROOM
c
6' -0" x 6' -S"
2/42.1
5
ENTRY FOYER
B
2' -S" x 6' -S"
STAIN/STAIN
HW -1 / 605
DK -1
LOCK -1
1 /42.1
6
ENTRY
D
3' -0" x 6' -S"
1
HALLWAY
D
2' -3" x 6' -8"
S
ENTRY FOYER
D
2' -S" x 6' -8"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (5) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED N
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
(E) EXTERIOR 51-IEATHING
WOOD TRIM TO MATCH (E),
PAINT /STAIN tO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ GATT
INSULATION
WOOD FRAME
KERV AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RO. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PANT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
DOOR JAMB
DOOR SILL
(E) EXTERIOR SHEATHING
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP 1U1 BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
(E) WD. SIDING
PRE- PRIMED, CsALV SHEET METAL FLASHING
OVER SELF- ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
SELF - ADHERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE IS VISIBLE BELOW
FLASHING EDGE
2X CANTED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) BLDG. PAPER
BACKER ROD AND SEALANT
SELF- 4DWEARNG MEMBRANE
TRIM- PAINT TO MATCH (E) TRIM
DOOR HEAD
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF - ADHERING MEMBRANE
REMOVE (E) WOOD SIDING MD
REPLACE AS REQ'D. CAREFULLY LIF
(E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF
SELF - ADHERING MEMBRANE AGAINST
SHEATHING. EXTEND SELF- ADHERING
MEMBRANE 4" UP WALL FROM TOP OF
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
SELF-ADHERING MEMBRANE. TYP. AT
HEAD AND JAMB
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
PRE- PRIMED GALV. FRY REVEAL TRIM )111iik •
CONTINUOUS 2x SOLID BLOCKING AROUND
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
SELF- ADHERI1•s MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
WD. TRIM BEYOND
ll
"L" MIN. BETWEEN PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
SEALANT
EXISTING GRADE OR SUBSTRATE
(E) BEVELED UJD. SIDING
(E) EXTERIOR SHEATHING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTNUE OVER SLIDING GLASS
DOOR FRAME
(E) PRIMARY SLIDNG
GLASS DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) UV. FLOOR FRAMING
DOOR SILL
SECONDARY SLIDING - DOOR DETAIL SET
3 " =1' -0"
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 05800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
)CaEVIEWED FOR
DE COMPLIANCE
t APPROVED
MAY 10 2011
City of Tukwila
BUILDING niVISlnni
RECEIVED
APR 2 9 2011
'MITER
in,
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 90100
(208) 624 -2777 • FAX (206) 624 -2073
2/24/11
0810.03.1741
CYL
0
0
J
z
0
F-
z
w
z
KING COUNTY
MPROVEMENTS
0
w
2
w
ce
w
0
z
LL
W
ce
AIP NUMBER
5 -53 -0058 -043
DATE
ISSUED
2/24/11
BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1741
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF- ADHERING
MEMBRANE. TYP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE- PRIMED, GALV. SHEET METAL
FLASHING W/ F.F. END CAPS UNDER
SELF- ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH: PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF - ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
i i i t P•IM• i' •i •i •' •m • i i pis' �S� •i •i i �i'. •i! •i' i �'+�� i ilk
CROSS SECTION
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2"X SPACER
7
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW 1" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
RIDGE VENT BAFFLE DETAIL
1 -1 /2" = 1' - 0"
BLENDING AIR UNIT DETAIL
1 1 /2" = 1' - 0"
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
DISPLACE (E) INSULATION
TO FACILITATE INSTALLATION
OF MECHANICAL UNIT, DUCTS
AND ACCESS HATCH
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
INSULATION STOP AT
PERIMETER OF ACCESS
HATCH OPENING, 4 SIDES -
2x WD BLOCKING
12"X16" ACCESS HATCH
FOR MAINTENANCE
3 BLENDING AIR UNIT DETAIL
1 1/2 "= 1 ° -0"
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
DISPLACE (E) INSULATION
TO FACILITATE INSTALLATION
OF MECHANICAL UNIT, DUCTS
AND ACCESS HATCH
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
INSULATION STOP AT
PERIMETER OF ACCESS
WATCH OPENING, 4 SIDES -
2x WD BLOCKING
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 10 2011
City of Tukwila
BUILDING DIVISION
bk• I
RECEIVED
APR 29 2011
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
2/24/11
0810.03.1741
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
O
0
z
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
MISC.
DETAILS
A2.2
0810.03.1741
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
CORNERS, TYP.
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND 1
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
11" MIN
`--11/2,„ " TYP.
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT r
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
WINDOW NAIL FLANGE.
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
BUTTERFLY CORNER FLASHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
‘‘‘
\\\\\\
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRI
(FOLLOWING STEPS).
L 1
HEAD FLASHING PREPARATION
/ SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND I -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL 51-EAT-IING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 514T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
5HOWN
DIAGRAMATICALLY.
(E) SIDING NOT
5HOWN FOR
CLARITY.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED. ALLOW 1/8"
LEARANCE
BETWEEN FLASHING AND
BOT. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOIIN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL 514EATHHING
(TYP. EACH SIDE
OF WALL)
C3-') MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
-Y-
. INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
\\\N
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 0120 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 14A5 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
COD�ILWED FOR
E COMPLIANCE
APPROVED
MAY 10 2011
EMOVE (E) SIDING BACK FROM (E) RO. A-5-4ozo-1311MTIJ la
(E) SIDING NOT SHOWN FOR CLARITY. REPLAC " , ILDING DIVI
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
NOTE: REMOVE
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL UV. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
1 WINDOW FLASHING INSTALLATION
SCALE: NTS
b1H01
RECEIVED
APR 29 2011
•; -:,, TCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(208) 624-2777 • FAX (208) 824 -2973
0810.03.1741
2/24/11
0
0
ce
Q
—J
z
0
z
w
z
z
0
U
z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
0
1-
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1741
:: � u;;:c;;; s;; »;:;u>:•;;;;;;;;rsxo-rr;::;;r �::•;;: cro-;:: a::: c;;>;;;;; r»:::: ::•r;:•x;>:;;o-;;r;;::
+,:•; >s;ts
iiF,:�i:i'r'i:•:::
}
{' }:} `:;ii >: £'r? : •
>:5;:::> {iii
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 514T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E) SIDING,
5HOWN
DIAGRAMATICALLY.
(E) SIDING NOT
5HOWN FOR
CLARITY.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED. ALLOW 1/8"
LEARANCE
BETWEEN FLASHING AND
BOT. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOIIN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL 514EATHHING
(TYP. EACH SIDE
OF WALL)
C3-') MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
-Y-
. INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
\\\N
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 0120 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW 14A5 BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
COD�ILWED FOR
E COMPLIANCE
APPROVED
MAY 10 2011
EMOVE (E) SIDING BACK FROM (E) RO. A-5-4ozo-1311MTIJ la
(E) SIDING NOT SHOWN FOR CLARITY. REPLAC " , ILDING DIVI
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
NOTE: REMOVE
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL UV. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
1 WINDOW FLASHING INSTALLATION
SCALE: NTS
b1H01
RECEIVED
APR 29 2011
•; -:,, TCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(208) 624-2777 • FAX (208) 824 -2973
0810.03.1741
2/24/11
0
0
ce
Q
—J
z
0
z
w
z
z
0
U
z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
0
1-
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1741
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E. EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
VD
VTR
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL ABBR
XX
OR XX
95
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X/Y X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
■
SAL S T E M P E A V
ARCHITECTS
A Proloodmal UrAlteil 3.iAb1Hiiy' Compaq
4.000 DEL RIDGE WAY SW
SOME 200 • SEATTLE, WA 98100
(n) 34734 -2777 • PAX (231$) 1$24 -2672
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL ABBR
SG-X XX
11 F-m-DNI DN
i-upi 4-
+ +
/L + VD
RA/EA
UP
RG
-1-> SA
1><I
-el- w-
SA
RA /EA
SD
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
OR T, THERMOSTAT
EQUIP ID# __ EQUIPMENT LOCATION
ICI
MOD
NG NG
0
•1
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1,2
BLENDING UNIT VENTILATOR
120
1
X
6"
6"
X
WALL CAP
1, 2, 3, 4
X
90
1,2
-
SWITCHES (ON, TIMER)
120
1
1, 2, 3, 4
X
25
X
4"
4"
X
DECO
1
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
120
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
BV -2
90
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
4
SG -1
220
<.08" WG
6"
6"
CEILING
DECO
1, 2, 3
SG -2
140
GO8" WG
6"
6"
CEILING
DECO
1, 2, 3
OG -1
120
<08" WG
6"
6"
WALL
WALL CAP
1, 2, 3, 4
OG -2
90
<.08" WG
6"
6"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
GO8" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1741 BV -1
1412
4
120 CFM
120 CFM
1
0810.03.1741 BV -2
958
-
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
THE GREENBUSCH GROUP, INC
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION.
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
SET BV -2 SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
MECHANICAL VENTILATION CALCULATION BV-1
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 512.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 60 / (1 X 1/2) = 120 CFM
MECHANICAL VENTILATION CALCULATION BV-2
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 311
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/3
QF = 30 / (1 X 1/3) = 90 CFM
1)1,1Nft 101
RECEIVED
APR 29 2011
PL -.,.:,TCENTER
VAS
�QPR RED
REouI
AUDIO / VIDEO Ss 11121114101/ 12614EV710
1900 1113T isoKosoN SIDEE1 SUITE 201 SEPTIIX. WA 96119
(206) 37a -0569 (200) 3711-0041 c
r
O
I
z
0
Cri
CD
U)
z
w
w
0
ct
a.
0
w
w
w
0
L
z
w
0
w
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/
ISSUED) F311 :) PACKAGE: S -23
100% CD
PROJECT ENGINEER
CA
PROJE.0 : :T MANAGER
CA
DRAWN
CA, MM & JA
LEGENDS,
SCHEDULES,
A R E 'U S . ,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.0 .1 741
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
2. HEATING IS PROVIDED DUCTED FURNACE.
SYSTEM NOT SUITABLE FOR OUTSIDE AIR
CONNECTION.
FLAG NOTES:
EIV -1 AND SiV -2 DUCTWORK ROUTED IN
ATTIC. USE EXISTING ATTIC ACCESS HATCH
FOR ELECTRICAL AND MAINTENANCE ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER
TO THE MINIMUM INSULATION THICKNESS
SCHEDULE ON M1.0.
SHEET METAL "Y" FITTING W/ VOLUME
DAMPERS.
QG -2
90 SEE
FAMILY
ROOM
(E)EXHAUST FAN
DINING
ROOM
SEE
FOYER
SG -2
140
TYP
CEILING GRILLES
MSG
E SG
KITCHEN
OFFICE
STOVE
b PROOM
3
TYP
LIVING
ROOM
4 "0
L
TYP
OG -1
120
CLOSET , ; CLOSET
_�.
AVOID 0
LIGHT
....... .. 44 4.4— .._ .. ... ........_.w.
CLOSET
IBEDROOM
4
54TH 1
54TH 2
(E)SG
IG
CE DG
C
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" =
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE
ACCESS
HOLD TIGHT TO
STRUCTURE
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
MIL
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
NONE
t 1N-A 0
RECEIVED
APR 29 2011
PERMITG NTTR
S.M. S 1 EleiPEJf.W
ARCHITECTS
4000 DELRIIDGE WAY SW
200 • NAME., TM 98/00
(2O) 0U-2777 • P (sty) 024 -24'73
THE GREENBUSCH GROUP, INC
A�oU5T1 L. % • �aWlQM. o nNo
IMO (208) 379 -0589 Sr sutE sA1 =TIE. W 98119
FAX
(200) 378 -0841 FAX
CD
Cif
0
.J
0
uJ
0
0
0
Y IMPROVEMENTS
EI T
w
w
w
0)
O
RESIDENTIAL ARC
AIP NUMBER
5-53-0058-043
SEATTLE WASHINGTON
DATE
2124/11
ISSUED E3Ii:) PACKAGE S -23
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
A
DRAWN
CA, MM & JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
0810.03.1741
EXPIRE •
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND 'TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH-IN. PAINT TO MATCH
SURROUNDING CONDIlIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AF ILR
ELECTRICAL PLAN NOTES
0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL-MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE
DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE
ATTIC.
MECI44NICAL 1 ELECTRICAL
coORDINATION
ITEM
NO.
EQUIPMENT
DESCRIPTION
VOLTS 1 PH
FURNISHED
UNDER DIVISION
CONTROL EQUIPMENT
INSTALLED WIRED
UNDER DIVISION UNDER DIVISION
BV-1-
BLENDING UNIT VENTILATOR
BLENDING UNIT VENTILATOR
SWITCHES (ON, TIMER)
REMARKS:
15 1 16 1 15
120 1 X
120 1 X
120
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
REMARKS
PROVIDE NEW RIGID STEEL
MAST, WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW MAST
GUYS AND ANCHORS
ROOF..
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
FEES PAID BY
'; CONTRACTOR.
2"C, 3#3/0 CU
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
PANEL MP
200A
120/240
1-PH, 3W
EXIST PNL
(1
r
2"C 3#3/0 CU.& GND
PROVIDE METER BASE
PER SCL STANDARD
#DU13-4/NMT-30
#4CU GROUNDING
ELECTRODE CONDUCTOR AND
GROUND RODS PER CODE.
MAX 10 OHMS TO GROUND
•
•
•
•
•
•
•
REUSE EXISTING
PANEL AS J-BOX.
SCREW COVER WITH
SELF-TAPPING
SCREWS AND LABEL
AS J-BOX ONLY.
PROVIDE NEW S.E.
RATED PANEL BOARD.
INTERCEPT AND
EXTEND EXISTING
CIRCUITS AND
CONNECT TO NEW
BREAKERS.
PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED
TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON
DRAWINGS.
ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE
STRUCTURAL SOLID 2X6 BLOCKING IN ATTIC FOR MAST.
PROVIDE BLOCKING AND UNISTRUT ASSEMBLIES TO HOLD
CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING
CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS
PRIOR TO BID.
EW SERVICE DETAIL
NOT TO SCALE
15/1
PTh. BLACK
L 0 0
N
WHITE
BLACK
WHITE
RED
BLACK
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYt1301.
DESCRIPTION
FE 0 QU RIPsp ME ENaT FICON C RE N clu EC I 11 R2MNE, NSEE Ts. EQUIPMENT CONNECTION SCHEDULES
DAMPER CONNECTION
G
1111 1
UGHTING OR POWER PANEL
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
Ax
1LV
0
wIt
0
DI
NON-FUSED DISCONNECT SNATCH
MAST, WEATHERHEAD
DI
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
----0--
BRANCH CIRCUIT HOME RUN
E")
FIRE ALARM SMOKE DETECTOR 120V OPERATED
EJ
ELECTRICAL MEIER
CI
FIRE ALARM SMOKE DETECTOR/CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11U1Y.
TIMER OPERATED SWITCH
LOAD DESCRIPTION
TYPE
CI
THERMOSTAT
PANEL
(E)KITCHEN
LOCATION: 0810.03.1741
10,000
120/240
VOLT,
1 PHASE, 3
VVIR E.
BKR
SERVING:
AIC,
200 AMP with MAIN
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
EXISTING CKT
40/2
A
B
70/2
EXISTING CKT
2
4
5 .
7
9
11
13
EXISTING CKT
EXISTING CKT
EXISTING CKT
30/2
40/2
20/1
A
A
A
€3
B
30/2
3012
20/1
EXISTING CKT
EXISTING CKT
EXISTING CKT
6
8
10
12
14
15
17
19
21
23
EXISTING CKT
EXISTING CKT
EXISTING CKT
EXISTING CKT
EXISTING CKT
2011
2011
20/1
15/1
15/1
A
A
B
8
B
15/1
2011
2011
20/1
20/1
EXISTING CKT
EXISTING CKT
EXISTING CKT
EXISTING CKT
EXISTING CKT
16
18
20
22
24
25
27
EXISTING CKT
EXISTING CKT
1511
15/1
A
B
1511
1511
EXISTING CKT
EXISTING CKT
26
28
29
A
2011
BLENDING UNIT
30
31
33
35
37
A
A
B
8
2011
SMOKE DETECTORS
32
34
36
38
39
13
40
PHASE LOAD PHASE A:::
KVA,
PHASE D:,
KVA.
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL. LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
0 ISOLATED GROUND BUS
0 RAINTIGHT NEMA-3R ENCLOSURE
FEED THRU LUGS
DOUBLE LUGS
MAIN SKR SHUNT TRIP
SERVICE ENTRANCE LABEL
0 PANEL SKIRTS
E3 INTEGRAL
SURFACE
FLUSH
•
•
111
0
0
TVSS 12
REMARKS:
SE ED F.C.- 01-1
L 05E-1
L. I V 1,1G,
L S.4"
FULL
DOWN STAIR
MP/32
MAIN FLOOR PLAN
1/4" = 1'
D I IUN
77-2.001-1
K 1 T FEN
F L
Room
MP/26
FOYER
RETAIN EXISTING PANEL
BOX AND CONDUIT FOR
J-BOX. INTERCEPT AND
EXTEND EXISTING BRANCH
CIRCUITING TO NEW
PANEL AS REQUIRED.
OFF ISE
ROUTE CABLE TO
NEW PANEL UNDER
EAVE, SIMILAR TO
EXISTING CONDITION.
PANEL MP
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
PROVIDE NEW METER BASE,
RIGID STEEL MAST,
WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
FEES PAID BY
CONTRACTOR.
PROVIDE NEW WEATHER
HEAD, MAST GUYS AND
ANCHORS AT EXISTING
LOCATION. PROVIDE
NEW ROOF FLASHING.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
TRIM VEGETATION TO
,—TRIM
MINIMUM 36"
CLEARANCE AROUND
e
SERVICE WIRES PER
SCL REQUIREMENTS.
b1,1-1101
RECEIVED
APR 29 2011
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
1.000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 621-2777 • FAX (206) 624-2973
simeimEEne, INO
0810.03.1741
MPROVEMENTS
>-
0
w
w
(/)
0
z
Ll-
LU
AIP NUMBER
5-53-0058-043
DATE
02/24/11
ISSUED BID PACKAGE M-24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1741