HomeMy WebLinkAboutPermit D11-111 - REICHLIN RESIDENCE - IMPROVEMENTREICHLIN RESIDENCE
4008 S 114 ST
Dil-lil
City* Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3351400475
Address: 4008 S 114 ST TUKW
Suite No:
Project Name: REICHLIN RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -111
Issue Date: 06/24/2011
Permit Expires On: 12/21/2011
Owner:
Name: MCKENNA CATHERINE
Address: 4008 S 114TH ST , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: CADENCE CONSTRUCTION INC
Address: 5821 S FLETCHER ST , SEATTLE WA 98118
Contractor License No: CADENCI915JB
Phone: 206 - 296 -7437
Phone: 206 - 355 -8340
Expiration Date: 04/05/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION .AND ABATEMENT).
Value of Construction: $23,071.50 Fees Collected: $905.73
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D11 -111 Printed: 06 -24 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date:
- -11(-1(
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of thi pe 't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or t pe ormance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: Date:
Print Name: " PA, vv._ ( / S 1 "--t�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-111 Printed: 06 -24 -2011
this requirement.
• •
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Muiucipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Thkwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -111 Printed: 06 -24 -2011
CITY OF TUKWIL•
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.cLtukwila.wa.us
Building Peo. bt ■ `'
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
0 '6 101 03. ISO
Site Address: 4008 S. 114th St.
Tenant Name: Theresa Reichlin
King Co Assessor's Tax No.: 335 I Db 91 -G
Suite Number: Floor:
New Tenant: ❑ Yes .. No
Property Owners Name: Theresa Reichlin
Mailing Address: 4008 S. 114th St.
Seattle
WA
98168
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H: Applications \Forms - Applications On Line \2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORM ION — 206-431 -3670
Valuation of Project (contractor's bid price): $ 23,032 23, p9- � t SO Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
Z.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:',Applications \Forms-Applications On Line.2009 Applications 1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1s` Floor
725
2nd Floor
3`d Floor
Floors thru
Basement •
725
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:',Applications \Forms-Applications On Line.2009 Applications 1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
• •
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 0
Signature:
I %��•
r
Print Name: TI tM f7T" � f L.51) 1J
Mailing Address: t'(000 Vet rt o a5e� 2-00
ORIZED AGENT:
Date: 24 L(
Day Telephone: 2O (p -1o2'f - 21-14
62 WA x(81'0-6
City
State Zip
Date Application Accepted:
Date Application Expires:
(0-)-s"--- V
Staff Initials:
U�2
H:Wpplications\Fonns- Applications On Line'2009 Applicationsx1 -2009 - Pennit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: htq)://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3351400475 Permit Number: D11 -111
Address: 4008 S 114 ST TUKW Status: PENDING
Suite No: Applied Date: 04/25/2011
Applicant: REICHLIN RESIDENCE Issue Date:
Receipt No.: R11 -00854
Initials:
User ID:
TLS
1670
Payment Amount: $905.73
Payment Date: 04/29/2011 08:58 AM
Balance: $0.00
Payee: KING COUNTY /PHONE AUTH
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 024034
ACCOUNT ITEM LIST:
Description
905.73
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $905.73
546.20
355.03
4.50
doc: Receiot -06 Printed: 04 -29 -2011
iv. .
• INSPECTION NO:
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
•• CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Bavd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pt `ect: i
j (j
ection:
Address: ,-I
4120 ti4 CT-
Date Called:
fr C-1,
Special Instructions:
•
•
Date Wanted: ..4. i
f- i
•
cJE
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: 011 -111
PROJECT NAME: REICHLIN RESIDENCE
SITE ADDRESS: 4008 S 114 ST
X Original Plan Submittal
Response to Correction Letter #
DATE: 04 -29 -11
Response to Incomplete Letter #
Revision # After Permit Issued
DEP RTM NTS:�t+ I �, t•Ifk r `1
Building ivision l te\Prevention
IA lk
P cTic ./V Nk 1 Structural
Vt-OC'o1 \
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -03-1 1
Complete Ill Incomplete ❑
Comments:
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route 141 Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05 -31 -11
Approved n Approved with Conditions NI Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing siip.doc
2 -28 -02
Contractors or Tradespeopl rinter Friendly Page
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name CADENCE CONSTRUCTION INC UBI No. 602882989
Phone 2063558340 Status Active
Address 5821 S. Fletcher Street License No. CADENCI915JB
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 4/2/2009
State WA Expiration Date 4/5/2013
Zip 98118 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty.
1
Specialty
2
Effective
Date
Expiration
Date
Status
CADENC*971K2
CADENCE
CONSTRUCTION
Construction
Contractor
General
Unused
5/22/2003
8/9/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
NISSINEU, KIMMO JOACHIM
President
04/02/2009
Amount
KELLEY, KATIE ANN
Vice President
04/02/2009
CGL000758622
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
& INDEM CO
799434C
03/18/2009
Until Cancelled
$12,000.00
04/02/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
BERKLEY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2010
11/26/2011
$1,000,000.0011
/03/2010
1
BERKELY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2008
11/26/2010
51,000,000.00
10/27/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
06/24/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO624C11 BID PACKAGE S -23
5- 53- 0058 -043
T REVIEWED FOR
CODE COMPLIANCE
APPROVED
MIRY 10 2011
CI'
BUILDING iI VISION
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
Plumbing
❑ Gas Piping
City of Tukwila
B_ UI! DING DIVISION
REVISIONS 1
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
SITE AND BUILDING INFORMATION
,JURISDICTION:
Department of Planning and Developement
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
international Fire Code,
international Mechanical Code
Washington State Energy Code
ZONING: SF-1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
COAISTRI.ICTION TYPE: (No Change)
V.8 NON SPRINKLERED
BUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
FILE COPY
NnNt
110,j21
Is subject to errors and omie&ons
documents does not authorizf
y adopted code or ordinance. Receip
Copy and l << • is acknowledged
City �1l� 1 kwita
BUILDING DIVISION
DRAWING INDEX
T0.0
A1.0
A2.0
A2.1
A2.2
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
111.0 LEGENDS, SCHEDULES, ABBPEV., GENERAL NOTES 4 DWG INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL 'PLANS AND PETALS
E1.0 ELECTRICAL PLAN
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E- mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stamper Architects P.L L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Fh 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmstemper.com
timesmstempercom
ACOUSTICAL ENGINEER
SSA Acoustic€ %
222 Etruria Street„ Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed:Ait Allaoua Contact Brent Rollins
E -mail: mohamedessaacoustics.com E -mail: bcretreswest.com
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
MECHANICAL ENGINEER
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98119
Ph 206.3180569
Fax: 206.318.0641
Contact: Chris Ager
E -mail: CMisAegreenbuschcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 ,Eastlake Ave. E., Suite 100
Seattle, WA: 98102
Ph: 206. 232. 9639
Fax: 206.162. 4180
Contact: Tim Ogden
E-mail: tIm ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. +'200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwelleJonespayne.com
VICINITY MAP
RECEIVED
APR 29 2011
PERMITCENTER
'.C2:CP.,
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
O
O
0
co
O
2/24/11
ft
0
CL
—J
0
w
z
O
0
z
MPROVEMENTS
im
ct
w
w
0
L
Ct
H-
Z
w
AIP NUMBER
5- 53- 0058 -043
z
0
C9
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1740
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 020S0 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
BASEMENT PLAN
1/4" = 1'
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OU,NERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS MO MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, MD REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS.
b. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED IJNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00 PH.
•1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE ENND OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAUJNGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO A5 NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POUTER MUST BE PROVIDED AT RESIDENCE BEFORE &.00 An 4 AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
BEDROOM
1
KITCI -IEN
DINING
ROOM
CLOSET
BATH
c
LIvING
ROOM
BEDROOM
2
A
1
MAIN FLOOR PLAN
1/4" = 1'
A. SOUTH ELEVATION
r
\
1
2-
7
\
7
W
1
B. WEST ELEVATION
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET A2.I
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I /A22 FOR DETAIL. COORDINATE WITH
MECHANICAL.
OINSTALL GABLE END BAFFLE TO (E) GABLE END VENT(S) REEF. 3 /A2.i FOR DETAIL
OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL.
OINSTALL ROOF VENT BAFFLE TO (E) ROOF VENT(5) REF. 5/A2.2 FOR DETAIL
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
L
l
. . . . . . . . . . . . . . /- -
-i
I_
2T -4"
1
ATTIC PLAN
1/4" = 1'
C. NORTH ELEVATION
REVIEWED FOR
JODE COMPLIANCE
APPROVED
MAY 10 2011
City of Tukwila
BUILDING DIVISION
D. EAST ELEVATION
LEGEND
i
ACOUSTICAL WINDOW
U:
.._. .wNOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.0
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
EXISTING KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
NOT USED
NOT USED
ATTIC INSULATION
RECEIVED
APR 2 9 2011
PERMITCENTER
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
I•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(208) 621-2777 • FAX (206) 824 -2973
0810.03.1740
2/24/11
0
0
CL
J
0
F-
z
ct
w
z
z
0
U
0
z
MPROVEMENTS
>-
0
w
w
w
u)
0
z
LL
U
Ct
J
H
z
w
0
w
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1740
WINDOW TYPES
{
SINGLE HUNG
2
CASEMENT
3
SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
LIVING ROOM
3
4' -8" x 4' -5"
PAINT/PAINT
REMOVE AND REN&TALL EXISTING SHUTTERS
I/A2.0
B
LIVING ROOM
3
4' -8" x 4' -5"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
I/A2.0
C
PINING ROOM
I
2' -10" x 4' -T'
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
I /42.0
D
KITCHEN
1
T -4" x 2' -9"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
SAFETY GLAZING
1/42.0
E
BEDROOM 1
I
2' -10" x 4' -5"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
1/42.0
F
BEDROOM I
2
2' -10" x 4' -5"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
Y
1142.0
G
BEDROOM 2
2
2' -I0" x 4' -5"
FAINT/PAINT
(REMOVE AND REN&TALL EXISTING SHUTTERS
Y
1/42.0
H
BEDROOM 2
I
3' -4" x 4' -5"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
1/42.0
1
BEDROOM 3
2
2' -9" x 1' -9"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
1/42.0
J
FAMILY ROOM
3
2' -9" x I' -9"
PAINT /PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
I /420
K
FAMILY ROOM
3
2' -9" x I' -9"
PAINT/PAINT
REMOVE AND REN&TALL EXISTING SHUTTERS
I/42.0
L
KITCHEN 2
3
2' -9" x 1' -9"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
1/42.0
M
KITCHEN 1
3
2' -9" x 1' -9"
PAINT/PAINT
REMOVE AND REINSTALL EXISTING SHUTTERS
SAFETY GLAZING
1/42.0
(E) = EXISTING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SWEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WNDOW ASSEMBLY
CAREFULLY CUT SACK (E) WD. SIDING
WINDOW HEAD
TO ALLOW FOR REATTACHMENT TO RA.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD +t SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
Ft
WINDOW JAMB
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING I PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WO SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT /STAIN TO
MATCH (E) TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP 111/ BATT
INSULATION
WINDOW SILL
(E) GWB
WOOD TRIM TO MATCH
(E), •AINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
51-11M AS NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD I
SEALANT
3/8”
3/4" WD. SILL - STAIN TO
MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT/STAIN TO
MATCH (E) TRIM
LF- ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3" = 1' - 0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
N SECTION 09800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 10 2011
City of Tukwila
BUILDING nIVIRInN
1)11 -III
RECEIVED
APR 29 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 824-2073
0810.03.1740
2/24/11
H
0
a
-J
Q
Z
0
z
w
z
z
0
v
0
MPROVEMENTS
0
w
2
w
ce
w
0
z
u_
U
ce
J
1—
z
cc
AIP NUMBER
5 -53- 0058 -043
z
0
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1740
DOOR TYPES
0
FLUSH SCW
W/ OBSERVATION PORT
FLUSH SCW
1 LITE W/
2 PANELS
W /SAFELY GLAZING
c
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
SELF- ADHERING
I
ENTRY
A
3' -0" x 6' -8"
PAINT/PAINT
1-1W -1 1626
DK -2
LOCK -I
I 1A2.1
2
KITCHEN
B
2' -6" x 6' -S"
PAINT/PAINT
HW -1 / 626
DK -2
LOCK -1
2/A2.1
3
DINING ROOM
B
Z' -S" x 6' -1"
PAINT/PAINT
4-111J-1 / 626
DK -2
LOCK -1
3/A2.1
4
ENTRY
C
3' -0" x 6' -S"
PAINT/PAINT
`��mra
WOOD TRIM TO MATCH (E),
/SLAIN TO MATCH (E)
1 /A2.1
5
KITCHEN
C
2' -6" x 6' -8"
PAINT/PAINT
WOOD TRIM TO MATCH (E),
2 /A2.1
6
PINING ROOM
G
2' -S" x 6' -1"
PAINT/PAINT
I
/
1
AIM
SHIM AS NECESSARY
FILL GAP W/ BAtt
INSULATION
WOOD FRAME
3 /A2.1
t REVIEWED FQR
CODE COMPLIANCE
' APPROVED
MAY 102011
City ofTukwfia
BUILDING DIVIRirw
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING 15 INDICATED, BUT NOT SCHEDULED
IN SECTION 0SS00 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OF'ERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E)
(E) SIDING
(E) WD. SIDING
WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT :'
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) >
I
I
I
�J
(�
SELF- ADHERING
WD.
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
I
_J
)
��
SELF- ADHERING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL LOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
I
SELF - ADHERING
:1
MEMBRANE
(E) EXTERIOR SHEATHING
)
��_,
MEMBRANE
(E) EXTERIOR SHEATHING
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB �r
I
I I
II
�j
MEMBRANE
(E) EXTERIOR SHEATHING
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
ANp JAMB 'a
I
II
11
,
WALL UNDERI.AYMENt OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
r ,i,
� �
WOOD TRIM TO MATCH (E),
PAINt/St TRIM
TO MATCH (E)
h
I
\\\\
►
,'
`��mra
WOOD TRIM TO MATCH (E),
/SLAIN TO MATCH (E)
i
WOOD TRIM TO MATCH (E),
'I
I
I
REMOVE (E) WOOD SIDING AS REQ D
FOR INSTALLATION OF POOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
I
III
III
I
/
1
AIM
SHIM AS NECESSARY
FILL GAP W/ BAtt
INSULATION
WOOD FRAME
REMOVE (E) WOOD SIDING AS REQ'D =
FOR INSTALLATION OF DOOR ASSEMBLY
TRIM. REPLACE W/ NEW SIDING PAINT
i1
II
111
',,�
l\
`
`�
PAINT
TRIM
SHIM AS NECESSARY
FILL GAP W/ GATT
INSULATION
REMOVE (E) WODO SIDING AS REAP
FOR INSTALLATION OF DOOR ASSEMBLY
TRIM. REPLACE W/ NEW SIDING 4 PAINT
III
I!
�;
I
I
,010
PAINt/StAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
TO MATCH (E) SIDING
TO MATCH (E) SIDING
'
• r-- --�
�
\
TO MATCH (E) SIDING
-
\
1'
V
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
. 1
KERF AS REQUIRED FOR
WEATHER STRIPPING
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
`����
�!�
i
-��
KEG AS REQUIRED FOR
UJ1 =AtHER STRIPPING
INSTALLATION
- - - -
-. ,�!`�MVP/
•'
• °
i ������il
'
',�
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
SCHEDULE
_
�;
I�
1111■""""
_;.�
•. o
>i4
• +r,"
'
INSTALLATION
CONTINUOUS WEATHER-
M
��II,�
��I
INSTALLATION
CONTINUOUS WEATHER-
CONTINUOUS WOOD TRIM
DOOR
CAREFULLY CUT BACK (E) WD. SIDING
HEAD
CONTINUOUS SEALANT BEHIND Z BAR �.
FRAME
STORM SCHEDULE I
WEATHER
STRIPPING
SCHEDULE
STRIPPING
SCHEDULE
HEAD
+�
1
11
CONTINUOUS -
STORM DOOR PER
2" MN.
HEAD
(�
STRIPPING
SCHEDULE
POOR PER
DOOR PER
MIN.
DOOR PER
DOOR
CAREFULLY CUT BACK (E) WD. SIDING TO
POOR PER
2"
DOOR
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO R. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
i
Ili
I I
�I
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENt
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE ANP LAP UNDER
(E) WALL UNPERLAYMENT. CAULK, TOOL
FLUSH AND PAINT FASTENI =R HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
)
�I
II
I I
Il
�,
ALLOW FOR REATTACHMENT TO R.O. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PANT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
II
41°N
-•
(E) WOOD SIDING
FLASHING
(E) WOOD SIDING
(E) WOOD BIDING
`
(E) EXTERIOR SHEATHING
EXISTING FRAMING
■
,
�\
(E) EXTERIOR SHEATHING
_
SEAL ANT H IND
(E) EXTERIOR SHEATHING
I
I I
IN
��
FRAMING
*_, \
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
\
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
CONTINUOUS SEALANT BEHIND'
Z BAR FRAME
SCHEDULE
II
all
J
EXISTING
WOOD TRIM TO MATCH (E),
PAINT/sTAIN t0 MATCH (E)
CONTINUOUS BE
Z BAR FRAME
STORM SCHEDULE
M"'.+
"�-
N�� -+
PRIM
ii....=-7==1,71fil
��"
�
�
TRIM
SHIM AS NECESSARY
FILL GAP W/ BAIL
INSULATION
SCHEDULE
STORM DOOR PER
KEW AS REQUIRED FOR WEATHER
I I
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATt
INSULATION
SCHEDULE
.:
-.
M�
SHIM AS NECESSARY
FILL GAP W/ GATT
INSULATION
SCHEDULE
CONtINOUS WOOD TRIM
.
pr"
y
DOOR PER
KERF AS REQUIRED FOR WEATHER
STRIPPING NSTALLATION
`,,
�'
I
BACKER ROD 4 SEALANT
KEW AS REQUIRED FOR WEATHER
l
►" MIN
4
STRIPPING INSTALLATION
°MIN
r
DOOR PER
STRIPPING INSTALLATION
CONTINUOUS WEATHER-HER- STRIPPING
DOOR
JAMB
I-
DOOR PER
DOOR PER
CONTINUOUS WEATHER - STRIPPING
DOOR
JAMB
J
CONTINUOUS WEATHER- STRIPPING
DOOR
JAMB
JAMB BEYOND
WOOD SCHEDULE
HARDWOOD JAMB BEYOND
HARDWOOD JAMB BEYOND
DOOR PER
III
WOOD POOR PER SCHEDULE
WOOD DOOR PER SCHEDULE
iil
DOOR SHOE
DOOR SHOE
2" MIN.
SWEEP
AUTOMATIC DOOR SWEEP
.lam
AUTOMATIC DOOR SWEEP
��
M�
AUTOMATIC POOR
jii
i
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
METAL THRESHOLD
r
�ox
ALUMINUM THRESHOLD.
MI �
ADJUSTABLE SWEEP
i�•� i
� ,� ���;
`��
_.43.111��ad
STRUCTURE -
STRUCTURE
EXISTING FLOOR STRUCTURE
EXISTING FLOOR
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
EXISTING FLOOR
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
b 11
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
3 " =1' -0"
3 " =1' -0"
RECEIVED
APR 2 9 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624 -2777 • FAX (206) 824 -2073
0810.03.1740
2/24/11
ct
a_
J
z
0
z
w
1—
z
0
U
0
MPROVEMENTS
>-
o
w
w
ce
w
0
z
u_
Q J
w
ce
AIP NUMBER
5 -53- 0058 -043
z
0
I-
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1740
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF - ADHERING
MEMBRANE. TYP. At HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT t0 MATCH (E) SIDING
PRE- PRIMED, GALV. SHEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF - ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REP. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
tk.
REMOVE / REPLACE SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 "= 1' -0"
EXISTING
CEILING
STRUCTURE
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE W/ ADJ.
ARCHITECTURAL FEATURES PER
PLAN. COORDINATE SOFFIT
DIMENSIONS WITH MECHANICAL
CONTRACTOR AND FIELD
CONDITIONS
DUCT SOFFIT DETAIL
1 -1/2 "= 1' -0"
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
ATTACH 2x3 LEDGER TO EXIST. DECK
ATTACH SOFFIT FRAMING TO LEDGER.
COAT %" x I" WD BLOCKING W/
ADHESIVE AND INSERT AT (E) GWB
PANEL EDGE.
PROVIDE FINISH -GRADE PAINTABLE
GU I3 EDGE AND CAULK JOINT
DUCTS PER PLAN WITHIN SOFFIT
WHERE WIDTH OF SOFFIT EXCEEDS I6 ",
PROVIDE 2x2 SOFFIT FRAMING I6" O.C.
2x2 CONT. NAILER
/8" GUS- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
MATCH EXIST. SOFFIT Ht
INSULATION DAM DETAIL
3 " =1' -0"
INSULATION
INSULATION DAM
(E) WALL FRAMING
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
1 1..................,.................................................„
CR05S SECTION
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2 "X SPACER
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW I" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
ROOF VENT BAFFLE DETAIL
11/2 " =1' -0"
RE-VIEWED FOR
CODE COMPLIANC E
. APPROVED
MAY 10 2011
City of Tukwila
BUILL1IN(niviclnN
EXIST. WALL
CONSTR
(2) SIMPSON A-34
e EACH SIDE PANEL
OPEN TOP
EXIST. GABLE
VENT
NEW #" GALV.
HARDWARE
CLOTH
i" COX PLYWOOD
AT (3) SIDES
I" OWENS CORNING x'103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
I. AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
GABLE END VENT BAFFLE
1 1/2" = 1' - 0"
til
RECEIVED
APR 29 2011
PERMIT CENTER
s.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1740
2/24/11
0
0
J
Q 0
z w
O �
� W
Ct
Z L1J
LU
Z
O
U <
Ca J
Z Q
w
0
co
W
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1740
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE:
REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
•
12"
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I ill
BEYOND RO. ATfff EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
II" MIN
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
}3UTTERFLY CORNER FLASHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
C
REMOVED
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER SACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
C
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
SEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE ANP
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
7
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
14EAD TO PREPARE
FOR INSTALLATION OF
14EAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
3" TYP.
f-f
{;:�F }`4•ii�`'. :iv •y
.ti v i'`" i ,';:«i':,vi'.vL. 4}, : :''vi}v }4` i . \ ; ;•.{ ti
}, S•.,{Qv .{+•k'• i ', : }
i : ;40:: ::. A.ti ',w•v; ;.}'v\v v:
^, :tiL ;y•'..,1}: �:' }•ti n+ •: ;'}•v'}v+• } ' {}•i4::;.\ }•`,; } :v}} } ti •\v �.:� 4,v{ti
x ."'v {{»� ..•.:vs\. ' .{v $y:.J�n,i•Sv `•
�i'. � �v,+ v
- } 4` +:vS}{v :{ Jv..'`"'i. '•.v,; 1• { +k
y ?• ^ \� :,'4 :4.'vi+..` +i:'•: . • } � �.}
{.hivM1;v'ti}\.fi,.h' v
}4 ' :h
':'>
'S•.i.,`. .`5v, th'':j •c
• vh1 v ••
C,'�'}.,'{�.`':':'''':..v•`:{
+}i •
•;:h :C} { �4•k '•:4
\ � $ : v v 4
:C•vv
}++44•;{'`.
• 1y;••�:} L'.1 � ,• t. v•+C`,;
v'v'+S' } {•} \`
\<\•.. C;+v.
, } y v,T•'
v ; ti
•'v�. } }• �.: \•:$h \1`•'.•1:11•: •L,:{ 'vii• }Li': :• }'`ti::::::k +L v4�2\:v''v }�4,vv4�}4 +.�,•`, �,•,;v;
{ix':•' :`•�42•. :i :: a \:'. {i . , � :i :
is {:.. �:�14h.... ti�•h }tip} }.\::.< 4 } \S.v h..
....<, •. `.: S::f +: i }i.• };` vv. v �•,` }{;` }{i •:, 2:2.1:1•• ::,\v.:v :v 2 ::2'.v •{. }{i •vi.�: <i'::':':
::ti: : ::4:• }:: }:v} •:• 1• } +:•: 4 }.vv }:h: h: h:•::•}::::•: }:�:::i {}.v.:.v}.v.:.vv l..v } n�.l.l•..v..v ..v: }: }::........Y: \. n'v Ni:•.. v.h.........
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
/
INSTALL 514T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR NSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
ALLOW 1/8" CLEARANCE
BETWEEN FLASHING AND
BOT. EDGE OF (E)
SIDING
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
C-9)HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
11 the
J 1
tip';
}`•,�•�` +'
i {.' {��. {' �'. {•::.
: }n
'1441
0 0 0
L,+A•,•;:,`:: i:}{':3ti'•`,•<;i'
1j}:} .: b.
vh+i
INSTALL JAMS FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
GENERAL NOTES:
1: MEMBRANE FLASHING I5 SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "S AND 9" REFER TO SWEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
ti
i WED FOR
R � O
CODE COMPLIANCE
APPROVED
MAY 10 2011
City of Tukwila
BUILDING DIVISIfN
SCALE: NTS
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
1
9)
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
O 0
J
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
RECEIVED
APR 29 2011
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2873
0810.03.1740
2/24/11
0
a_
ce
J
z
0
z
w
1—
z
0
0
0
z
MPROVEMENTS
0
Cw`
w
ce
rw^
V
O
z
J
ui
ce
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1740
ABBREVIATIONS
LEGEND
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEIUNG
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEIUNG DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STA11C PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STA11C PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
0
ABBR
AC>
xx
OR XX
0
X/Y
%/////////,
rZOM:a
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
1
DRAWING INDEX
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
XXX
s.
s
+ r +
,rs]
-I-)
EQUIP ID #\...
x
NG
•
0
DN
UP
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD VOLUME DAMPER
RA /EA RETURN AIR OR EXHAUST AIR DUCT
RG RETURN AIR GRILLE
SA SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RA/EA RETURN AIR OR EXHAUST AIR DUCT
SD
SA
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
449
G08 "WG
7 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
,
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
120
449
G08 "WG
7 "0
EXTERIOR
1,2
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1740
1579
3
120 CFM
120 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1
MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 5.Q
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION j
QF = 60 / (1 X 1 /2) = 120 CFM
RECEIVED
APR 29 2011
PERMITCENTER
4/
S.M. STEMPER
ARCHITECTS
A Pealaaali aak iSmikM liability Company
40OO DEICSIDGE WAY SW
Sinn 200 , SHAME, WA 90108
( ) sta4 -2771, • pAx (tea) 824 -$473
THE GREENBUSCH GROUP, INC
••00600f
12001,_ati / as s waaw . DaW n is
((22oe))337a8- 1�0000li STREET rum f 1 ! 370- w aeiia
( 37a -oe41 FAx
081 0.03.1740
KING O ITY INTERNATIONAL AIRPORT
ED'S IMPROVEMENTS
w
w
co
O
L
0
ry
0
w
0)
w
Alp NUMBER
5- 53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/111
ISSUED BID PACKAGE S -23
100 %CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM 8, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
081 0.08.1 740
L EXPIRES: 9/08/2012
CLOT
FINING
ROOM
CL O5 T
15AT I
2
8/6, EXPOSED, TO
MATCH ADJACENT
DUCT
KITCHEN
ROUTE DUCT
TIGHT TO WALL
AND (E)DUCT
BASEMENT MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
CEILING
TRANSITION ROUND TO
SQUARE DUCT BEFORE
GOING THROUGH WALL
PENETRATION
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
FURNACE
FLUE
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
DINING
ROOM
T
LIVING
ROOM
i
i
3
CUM
MAIN FLOOR MECHANICAL PLAN
2 SCALE: 1/4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
NIL
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL
WALL CAP CONNECTION DETAIL
SCALE: NONE
NORTH
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE 1411-10LE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51- 52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY — CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
b II -11
RECEIVED
APR 29 2011
PERMITCENTER
S.M. STEMPER
ARCHITECTS
A E4ohma9anat Kalmitiset Kelability Canapem
8 p
4000 D :LRIDGE WAY SW
90100
gees) 624-4777 • roc (gal) 8144 -e;
THE GREENBUSCH GROUP, INC
*410 •a 41411 •11,
1900 9� STREET tunE 401 SWILL WA 98119
(200) 3741-0669 (400) 370 -0041 FAX
0810.03.1740
NTERNATIONAL AIRPORT
KING COUNTY
EDY IMPROVEMENTS
FT NOISE RE
RESIDENTIAL A1RC
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
BASEMENT
AND MAIN
FLOOR
MECHANICAL
PLANS AND
DETAILS
PANEL
MP
LOCATION:
SERVING:
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
1,2
1201240
VOLT,
1 PHASE, 3
WIRE.
BKR
DESCRIPTION
RESIDENCE
AIC,
125
AMP with MAIN
24
1
15
X
16
15
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
EXIST CKT
— - —
40/2
A
1
30/2
EXIST C KT
2
3
5
7
9
11
EXIST CKT
EXIST CKT
EXIST CKT
40/2
20
20
A
A
B
B
B
" *15 -15
15
20
30
0.01
D
EXIST C KT
SMOKE DETECTORS EXIST CKT
EXIST C KT
EXIST C KT
EXIST C KT
4
6
8
10
12
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOT4L LOADS
CONN. LOAD
0.01
0.01 KVA
0.04 AMP
COMPUTED LOAD
0.01
0.01 KVA
0.04 AMP
❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS [] MAIN BKR SHUNT TRIP
❑ RAINTIGHT NEMA 3R ENCLOSURE ❑ DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL
PANEL SKIRTS
INTEGRAL
SURFACE
FLUSH
•
•
CJ
TVSS ❑
REMARKS:
** PROVIDE BREAKER TO MATCH EXISTING
15/1
BLACK
L
N WHITE
ME:CLANICAL 1 ELECTRICAL COORD[NATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
1,2
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
-
MOTOR OPERATED DAMPER
24
1
15
X
16
15
16
X
N/A
15
16
X
N/A
-
THERMOSTAT
24
1
X
FIRE ALARM SMOKE DETECTOR 120V OPERATED
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
TIMER OPERATED SWITCH
THERMOSTAT
®■-
X
— - —
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLACK
WHITE
RED
BK
1
BLACK
WHITE
,..•••••„
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
ELECTRICAL LEGEND
3'11~I 301_
DESCRIPTION
SYMBOL
DESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
111i Li
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
02 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
Y
DAMPER CONNECTION
❑'
NON -FUSED DISCONNECT SWITCH
a
MAST, WEATHERHEAD
ES'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
ELECTRICAL METER
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTIUTY.
J
FIRE ALARM SMOKE DETECTOR 120V OPERATED
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
TIMER OPERATED SWITCH
THERMOSTAT
®■-
— - —
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
a PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
REMOVE EXIST BREAKERS AND PROVIDE 1/2 SIZE BREAKERS AS INDICATED TO MAKE SPACE FOR SMOKE DETECTOR CIRCUIT.
05 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE BACK
BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 12OVac AND PROVIDE
COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL. SEE GENERAL NOTES FOR CEILING PENETRATION REQUIREMENTS.
0 HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL
PENETRATION WORK. PROVIDE 2 #14 &G TYPE NMB CONDUCTOR FOR SMOKE DETECTORS. SEE PANEL SCHEDULE.
CLOSET
K1TONEN
BASEMENT PLAN
%nMIL T
ROOM
1
0
114" = 1'
NORTH
ILE
0
MAIN FLOOR PLAN
114" = 1'
2
� - - - -- F q�9 �
��p�a
0
RECEIV�9F
APR 29 2011
PERMITCENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRHDGE WAY SW
SUITE 200 • SEATTLE, WA 981.06
(206) 624 -2777 • FAX (206) 824 -2973
CN�INELNi. INO
0810.03.1740
0
0
J �` z
< • O
▪ I-
0 u Oz
- ft
✓ _ Q
L.0 0
Z J
(�
LL �-
LLI
Z U Ci)
Ct
o _
V <
0 J
Z Q
z
0
Cr)
OC
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1740