HomeMy WebLinkAboutPermit D11-112 - MCKENNA RESIDENCE - IMPROVEMENTMCKENNA RESIDENCE
4008 S 114 ST
D11-112
City ofii'ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3351400475
Address: 4008 S 114 ST TUKW
Suite No:
Project Name: MCKENNA RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -112
Issue Date: 06/24/2011
Permit Expires On: 12/21/2011
Owner:
Name: MCKENNA CATHERINE
Address: 4008 S 114TH ST , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: CADENCE CONSTRUCTION INC
Address: 5821 S FLETCHER ST , SEATTLE WA 98118
Contractor License No: CADENCI915JB
Phone: 206 - 296 -7437
Phone: 206 - 355 -8340
Expiration Date: 04/05/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $13,074.50 Fees Collected: $590.58
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by:
* *continued on next page **
doc: IBC -7/10
D11 -112 Printed: 06 -24 -2011
• •
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
LLa,
Date:
62-- )-4 -1f
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit d es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performaice of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit.
Signature: Date:
M ��) S /ACM-
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11 -112 Printed: 06 -24 -2011
this requirement.
• •
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11-112 Printed: 06 -24 -2011
1. -
CITY OF TUKWILO
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: //ivww. ci. tukwila. wa. us
Building PerreNo. �..
c <<
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: 3351400475
Site Address: 11311 41st Avenue S.
Tenant Name: Catherine McKenna
Suite Number:
Property Owners Name: Catherine McKenna
Mailing Address: 11311 41st Avenue S.
Floor:
New Tenant: ❑ Yes ® ..No
Seattle
City
WA 98168
State Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:Wpplications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ION — 206- 431 -3670
Valuation of Project (contractor's bid price): $ 995 131 O t-k t GV Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
1— ApplicationsToans- Applications On Line 2009 Applications'. 1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
lst Floor
372
2nd Floor
3`d Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION /HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
1— ApplicationsToans- Applications On Line 2009 Applications'. 1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
• •
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section. 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER
Signature:
ORIZED AGENT:
Date: ' L I
Print Name: TIM bTb ( 2 • PEN (i$o N Day Telephone: 2—O(o - (D 2.-`f 71-7- A—
Mailing Address: 9eA r l def. Weil t;( 1 ,t 700 w °� 55 to(:, V City State Zip
Date Application Accepted:
Date Application Expires:
- t(
Staff Initials:
H,',Applications '.Forms- Applications On Line1009 Applications` 1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.:
Address:
Suite No:
Applicant: MCKENNA RESIDENCE
RECEIPT
Permit Number: D11 -112
Status: PENDING
Applied Date: 04/25/2011
Issue Date:
Receipt No.: R11 -00855
Initials:
User ID:
Payee:
TLS
1670
Payment Amount: $590.58
Payment Date: 04/29/2011 08:59 AM
Balance: $0.00
KING COUNTY /PHONE AUTH
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 024034
ACCOUNT ITEM LIST:
Description
590.58
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $590.58
355.20
230.88
4.50
doc: Receiot -06 Printed: 04 -29 -2011
;.
i•
INSPECTION RECORD
Retain a copy with permit
INSPEOTION NO. PERMIT NO.
• • CITY OF' TUKWILA BUILDING DIVISION
6300 Soutliden.tef Blvd., #100, Tukwila. WA 98188 a (206) 431-3670
• Permit Inspection Request Line (206) 431-2451
IOU -lit
iitift-ct: --1 _ '
•Mk o.(e_An 4 Res.
Type of Inspection:
p : iv 44 ,g, -.
Address: ' . _114 sr.
.0 O 8"_ _ t(1
Date Call.w.„, (1,1_-_ej
.0.
....-
,..'4_. .
bpecialTInstruttion"s:
•
Date Wanted:. '
/0 -( 2- -7 p.m.
Requester:
Phone No-
1)1- or1S-L.
proved per applicable codes.
Corrections required prior to approval.
COMMENTS:
• ef,Wri (,A okeTf
•
•T
Insp ctor:
\*P k
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenier\Blvd., Suite 100. Call to schedule reinspection.
Date
• •
PE T
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -112
PROJECT NAME: MCKENNA RESIDENCE
SITE ADDRESS: tiQQg G L k-i ‘-st
Original Plan Submittal
Response to Correction Letter #
DATE: 04 -29 -11
Response to Incomplete Letter #
Revision # After Permit Issued
EPARTMENTS:
141
L
uilding ivi Sion
Ic Works
Fire Pry' ention
Structural ❑
Planning Division j
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 055 -03 -11
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑
LETTER OF COMPLETENESS MAILED:
Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route 144 Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 05-31-11
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑
Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Peer Friendly Page
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name CADENCE CONSTRUCTION INC UBI No. 602882989
Phone 2063558340 Status Active
Address 5821 S. Fletcher Street License No. CADENCI915JB
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 4/2/2009
State WA Expiration Date 4/5/2013
Zip 98118 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
CADENC'971K2
CADENCE
CONSTRUCTION
Construction
Contractor
General
Unused
5/22/2003
8/9/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
NISSINEU, KIMMO JOACHIM
President
04 /02/2009
Amount
KELLEY, KATIE ANN
Vice President
04 /02/2009
CGL000758622
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
& INDEM CO
799434C
03/18/2009
Until Cancelled
$12,000.00
04/02/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
BERKLEY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2010
11/26/2011
$1,000,000.00
11/03/2010
1
BERKELY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2008
11/26/2010
$1,000,000.00
10/27/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
06/24/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00624C11 BID PACKAGE S -23
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
1'r' Mechanicat
electrical
e'iumbing
[was Piping
City of Tukwila
SUlLOING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOT: Revisions will require a new plan submittal
i t.ind may inc:ude additional plan review fees.
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Developement
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
Washington State Energy Code
ZONIix: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Chance)
v B NON SPRINKLERED
I
Pernit No.,
Plait review approval is subject to errors and omissions.
APB rova1 of cons documents does not authorize
talc v oiation of an adopted code or ordinance. Receipt
of approved Field py and conditions is adanowiedged:
BUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
Date:
City 0?lbkwita
BUILDING DIVISION
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
A1,0 FLOOR FLANS 4 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
A2.1 DOOR TYPES, SCHEDULE 4 DETAILS
422 MISCELLANEOUS DETAILS
A23 WINDOW FLASHING DETAILS
111.0 LEGENDS, SCHEDULES, ABBREV, GENERAL NOTES 4 DWG INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN ANP DETAILS
E1,0 ELECTRICAL PLAN
PROJECT DIRECTORY
KING COUNTY iNTL. AIRPORT:
Sound insulation Program
King County international Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.2%.0190
Contact: Sharyn Parker
E- mail: SharynParkamekingcounty.gov
ARCHITECT:
SM. Stamper Architects P11.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmstemper.com
timesmstemper.com
ACOUSTICAL ENGINEER:
ELECTRICAL ENGINEER:
SSA Acoustics Tres West Engineers
222 Etruria Street, Suite 100 2102 S. 42nd Street, Suite 301
Seattle WA 95109 Tacoma, WA 95409
Ph: 206. 539. 0Sle Ph: 253. 412. 3300
Fax: 206.839.0824 Fax: 253.412.3463
Contact: Mohamed Ait Allaoua Contact: Brent Rollins
E -mail: mohamedessaacoustics,com E- mail: bcretreswest.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson Sty Suite 201
Seattle, U14 98119
PIS 206.3180569
Fax: 206.315.0641
Contact: Chris Alter
E -marl: CMisA®greenbuschcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. Eq Suite 100
Seattle, WA 95102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E -mail: tlm ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. *200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwellejonespayne.com
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY�22011
Vi
ty of bide
BUILDING DIVISION
11
RECEIVED
APR 29 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1739
2/24/11
ct
0
11
J
Q d
z wwC
G
w
tX
z ,w
WI 0
z �
gil-
Z
0
z < JJ
1--
z
w
0
0)
w
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
2!24111
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1739
NOTES:
1. ASBESTOS CONTANING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
24" x 24" EXIST.,
ATTIC ACCESS
PANEL
NOTE:
KNOB AND TUBE WIRING F'RESE'NT.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OUJNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM N RESIDENCE FROM 5:00 FM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACI -I WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1,0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS POWER MUST EE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
li. CONTRACTOR 15 TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR N FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION 15 UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
MAIN FLOOR PLAN
1/4" = 1'
2'1' -5"
L_
L✓
T
NO INSULATION
REQUIRE /,..
24" x 24" EXIT.
ATTIC ACCESS
PANEL
22' -2"
A. NORTH EAST ELEVATION
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON 51-1EET A2,0
ODEMOLISH EXISTING OOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A2.2 FOR DETAIL. COORDINATE WITH
OMECHANICAL.
�BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND
DISCONNECT. REF. 2/42.2 FOR DETAIL.
0 COORDINATE CEILING GRILL WITH MECHANICAL.
O6 INSTALL INSULATION DAM AROUND (E) ATTIC ACCESS PANEL PRE DETAIL 4/422
OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
. .......:.::.:.............: ...... :., ....,: .. .. .. ....... >.a :...v,.,aw.c, � �:;;; >`; ?5•'.i;�t it a:..,aCxex:7..Ri:
B. SOUTH ELEVATION C. WEST ELEVATION
11N.- Ilz
TEVIWVVED FOR
#'1 COMPLIA N E
APPROVED
LEGEND
u
ACOUSTICAL WINDOW
NOT USED
EXTERIOR STORM DOOR
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.0
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
EXISTING KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
[II
NOT USED
NOT USED
MAY 12 2011
City of Tukwila
BUILDING QIVIgIj
RECEIVED
APR 292011
TCENTER
ATTIC INSULATION
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
IPnI
I•
S.M.STEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 90100
(206) 621-2777 • FAX (206) 624 -2073
•
0810.03.1739
2/24/11
0
0
ce
J Q
z
0
4=C
z
L1C
W
1--
z
0
z
U
z
MPROVEMENTS
>-
ctw
w
W
U)
0
z
LL
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1739
WINDOW TYPES
DOUBLE HUNG
2
CASEMENT
3
SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
ENTRY
3
4' -4" x 3' -4"
PAINT/PAINT
SAFETY GLAZING REQUIRED
1/42.0
B
KITCHEN
I
2' -10" x 2' -4"
FAINT/PAINT
I /A2.0
C
BEDROOM
2
2' -11" x 3' -6"
PAINT/PAINT
Y
I /42.0
D
LIVING ROOM
2
2' -II" x 3' -6"
PAINT/PAINT
1/42.0
E
LIVING ROOM
2
2' -II" x 3' -6"
PAINT/PAINT
1/42.0
F
LIVING ROOM
2
2' -11" x 3' -6"
PAINT/PAINT
SAFETY GLAZING REQUIRED
1/42.0
(E) = EXISTING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAP
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF- ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO W.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILNG FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) L. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
WINDOW HEAD
ACOUSTICAL WINDOW ASSEMBLY
J
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT/STAIN TO
MATCH (E) TRIM
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
In]
I II
WINDOW JAMB
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMNED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
0
WINDOW SILL
(E) GUS
WOOD TRIM TO MATCH
(E), PAINT/STAIN TO
MATCH (E) TRIM
WD JAMB LNNG
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
3 /S"
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT/STAIN TO
MATCH (E) TRIM
SELF- ADHERING
MEMBRANE
(E) GLUE
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
bE1l
REVIOWED FOR
CODE COMPLIANCE
APPROVED
MAY 12 2011
City of Tukwila
BUILDING fIVIsION
RECEIVED
APR 2 9 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 824 -2973
2/24/11
0810.03.1739
O
0
ct
J
z
0
z
w
z
z
0
0
z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
0
z_
CI)
w
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1739
DOOR TYPES
0
FLUSH SCW
W/ SIX PANELS
W/ OBSERVATION PORT
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
Wx H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY
A
2' -8" x 6' -8"
PAINT/PAINT
14111 -1 / 626
DK -2
LOCK -1
1 /A2.1
2
ENTRY
A
2' -6" x 6' -8"
PAINT/PAINT
14W -I 1 626
DK -2
LOCK -1
1/A2.1
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. 'MP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRA- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF -ADI -EKING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPNG
1
DOOR HEAD
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OvER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM NSTALLATION OF
FLASHING
(E) WOOD SIDING
BACKER ROP 4 SEALANT
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATI- ER- STRIPPING
0
1
SELF- ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
L.skuwitubi
DOOR JAMB
HARDWOOD JAMB BEYOND
WOOD DOOR
PER SCHEDULE
POOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
AL
EXISTING FLOOR STRUCTURE
DOOR SILL
WOOD TRIM TO MATCH (E),
PAINrt/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT/STAIN t0 MATCH (1:)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
z.
REVIOWED FOR
CODE COMPLIANCE
•, APPROVED
MAY 12 2011
City 01 Tukwila
_BUILDING nivisiCN
RECEIVED
APR 29 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 024 -2777 • FAX (206) 624 -2073
2/24/11
0810.03.1739
0
—J
.zL
I-
Q
z
w
z
z
0
0
0
z
MPROVEMENTS
0
w
2
w
ce
w
0)
0
z
u_
LL
1—
z
AIP NUMBER
5 -53 -0058 -043
z
0
Cn
LJJ
Q
C/)
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1739
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF- ADHERING
MEMBRANE. TYP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE - PRIMED, GALV. SWEET METAL
FLASHING W/ FF. END CAPS UNDER
SELF - ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
11
II
REMOVE / REPLACE SIDING AS
REQUIRED.
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 "= 1' -0"
b N. 11 2.,
C REVIEWED FOR
CODE COMPLIANOE
APPROVED
MAY 122011
t., City of Tukwila
BUILDIN( 111miON
RECEIVED
APR 29 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
0810.03.1739
2/24/11
0
0
Q
Z w
O
� w
aC
Z w
Z
gll-
Z
U
U <
CD J
Z Q
z
w
0
C!)
w
ce
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
0
z
co
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1739
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING I -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I i"
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
an' SILL
FLASHING 1 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
Ii" MIN
TYP.
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
51-1EATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
zo
SIf
BUTTERFLY CORNER FLASHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
O
NAIL HOLE S. REM VE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECI - INICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
cep
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PRE ARE
FOR INSTALLATION OF
HEAP FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 1
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAP, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
3" T'1'P
yy..
r
}ttiY<
•ee:':{'S+:'
0
0
0
0
Yiiii iii
:241:
'�RA•w:...v4C•..v .v
2.4•.v.
'•h�tii 24 •h•:
0
0
0
0
0 0 0
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECI - INICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
cep
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PRE ARE
FOR INSTALLATION OF
HEAP FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 1
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAP, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
3" T'1'P
yy..
`t }
i4.' SY.'+ S•;' n'4rSS.:.'Sti,'vS+:'+nn:'•$'S'.'
' +1475•:."55:'•4:
h 4v,
h ihU:S
}ttiY<
•ee:':{'S+:'
(
.,•:,v`•:
•:: t'..v
tvv4
Yiiii iii
:241:
'�RA•w:...v4C•..v .v
2.4•.v.
'•h�tii 24 •h•:
'v
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
1
INSTALL 514. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW US" CLEARANCE
BETWEEN FLASHING AND
SOT. EDGE OF (E)
SIDING.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
9� HEAD FLASHING INSTALLATION
9) SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SWOWrI EXTEND
I -1/2" BEYOND
RO. AT HEAD.
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
�3 MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) W. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
Th MEMBRANE FLASHING AT JAMB
SCALE: NTS
GENERAL NOTES:
1: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL MD STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, h, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "S AND '3" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
1 0� SCALE: NTS
WOOD TRIM INSTALLATION
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT SEAR TO
JOINT 15E11L.EEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
:h.
L_
J
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
I REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY i z 2011
City C' cfTukwi
BUILDING nnn
Ci of Tukwila
BUILDING nIVISiON
RECEIVED
APR 29 2011
PERMIT CENTER
S.M.STEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
2/24/11
0810.03.1739
0
a
-J
Z
0
z
w
z
0
U
0
Z
MPROVEMENTS
0
w
2
w
w
0
z
LL
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1739
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CI RC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
OR XX,
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -O" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
SYMBOL ABBR
XXX
I--- DN I 11 DN
UPI + UP
VD
RA /EA
RG
-I -0 SA
><I
SA
-01- el- RA /EA
a=1993:1
+ C5)
SD
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT WI INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
OR ® THERMOSTAT
EQUIP ID# `'� _ EQUIPMENT LOCATION
x
I ►1
MOD
NG NG
7
0
•
D'4
LisrA
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
115
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
1
SG -1
115
(08" WG
7"
7"
CEILING
DECO
1, 2, 3
00 -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1739
419
1
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
I MIN VALUE
(NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
bll- iiz
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 32
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/3
QF = 30 / (1 X 1/3) = 90 CFM
RECEIVED
APR 29 2011
pERAITCENTER
SEPARATE 40
PERMIT AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DEr EIDGE WAY SW
STATE Son • BATTLE, WA 98106
42O) 004-arm • FAX (e00) 6 4 -S0r5
THE GREENBUSCH GROUP, INC'
0** 6 **a *0)
ACOIISIICM . MA VA ®i 1d7wi i. EBlO0�0i
10001 ID SIREkT 8011E 201 118011$ ON N119
(20e) 37e-06ee (sae) 7$ -0841 PM
081 0.03.1 739
F-
0
z
0
rt
z
z
0
0
0
z
EDY IMPROVEMENTS
FT NOISE RE
0
w
0
w
ce
AIP NUMBER
5- 53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE S -23
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES,
DWG INDEX
M1.0
0810.03.1730
ENTRY
KITCHEN
CEILING GRILLES
LIVID!
ROOM 4-
115
7 "o
FURNACE
IN WAL.L.
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE
ACCESS
HOLD TIGHT TO
STRUCTURE
BV -1
ATTIC
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
t1001111411i
DUCT PER PLAN
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN ATTIC. USE
EXISTING ATTIC ACCESS HATCH FOR
ELECTRICAL AND MAINTENANCE ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51- 52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER
2. SEE PLANS FOR VOLUME DAMPER LOC
3. CEILING SUPPLY INSTALLATION SHOWN,
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEIUNG JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
ATIONS.
RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
NONE
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
APR 29 2011
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Prokseeload rAzdiod Liability Commpp
4000 DELEIDGE WAY SW
sum 200 • SHAITLE. WA MOH
H2O) 31t{4 -CM7 • FAX (200) 004 -2672
THE GREENBUSCH GROUP, INC
1 MI6Gt CN 1111 1E I
(206) 376 -0509 (200) 378 -041 FAX
0810003. 739
0
a
0
Lou
z
z
0
0
0
z
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AlP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BII :) PACKAGE S -23
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
. ®o a ® ® ®=951® ®®
M2.0
0810.03.1739
L -®0 0
N
BLACK
PANEL
MP
LOCATION:
SERVING:
DESCRIPTION
SY11301_
10,000
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
RESIDENCE
AIC,
200
AMP with MAIN
BRANCH CIRCUIT HOME RUN
0
FIRE ALARM SMOKE DETECTOR 120V OPERATED
[�
CKT
LOAD DESCRIPTION
TYPE
KVA
AAP
PHASE
A/P
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
5
EXISTING LOAD
EXISTING LOAD
3012
4012
A
A
B
40/1
30/1
30/1
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
2
4
6
7
9
11
13
15
17
19
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
A
A
A
B
B
B
B
3011
20/1
15/1
0.02
0.01
M
D
EXISTING LOAD
BLENDING UNIT
SMOKE DETECTORS
8
10
12
14
16
18
20
LOAD TYPE
L
R
M
H
WH
D
A
K
IM
TOTAL LOADS
CONN. LOAD
0.02
0.01
0.02
0.03 KVA
0.13 AMP
COMPUTED LOAD
0.02
0.01
0.01
0.04 KVA
0.15 AMP
ISOLATED GROUND BUS ❑ FEED THRU LUGS
RAINTIGHT NEMA -3R ENCLOSURE 0 DOUBLE LUGS
MAIN BKR SHUNT TRIP
SERVICE ENTRANCE LABEL
PANEL SKIRTS
INTEGRAL
SURFACE
FLUSH
■
■
■
•
❑
jJ
[
T ISS ]v+„
REMARKS:
ITEM
NO.
MECHANICAL / ELECTRICAL COORDINATION
EQUIPMENT CONTROL EQUIPMENT
DESCRIPTION
REMARKS
FURNISHED
VOLTS PH UNDER DIVISION
15 16
INSTALLED
UNDER DIVISION
15 16 N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
x
x
SWITCHES (ON, 11MER)
120
1
x
x
WIRED
UNDER DIVIS ON
15 16 N
X
x
1,2
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS
2 - DISCONNECT SWITCH
TYPICAL ALL)
BLACK
WHITE
WHITE
RED
BK
BK
BLACK
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
PROVIDE NEW RIGID STEEL
MAST, WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW MAST
GUYS AND ANCHORS
ROOF
ELECTRICAL LEGENI
SYMWOL.
DESCRIPTION
SY11301_
DESCRIPTION
LIGHTING OR POWER PANEL
BANRAD N ECH QU ICIP RICUDI
NIT C AWED IN G O N A NPD L ACONDUIT RAS RAEQ IRCED ON DFUOIR T CKSIZTS E MDAEY V ICNEO
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
MAST, WEATHERHEAD
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
DAMPER CONNECTION
NON -FUSED DISCONNECT SWITCH
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
G
0
Q'
IJ'
I I I I I I
0
BRANCH CIRCUIT HOME RUN
0
FIRE ALARM SMOKE DETECTOR 120V OPERATED
[�
ELECTRICAL METER
0
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
I
TIMER OPERATED SWITCH
- —
T�
THERMOSTAT
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE UMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
1 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
0 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE BACK
BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 120Vac AND PROVIDE
COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL. SEE GENERAL NOTES FOR CEILING PENETRATION REQUIREMENTS.
05 HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL
PENETRATION WORK.
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
FEES PAID BY
CONTRACTOR.
2 "C, 3 #3/0 CU
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
PANEL MP
200A
120/240
1 -PH, 3W
EXIST PNL
2 "C, 3#3/O CU.& GND
PROVIDE METER BASE
PER SCL STANDARD
#DU13- 4 /NMT -30
E--- --- PROVIDE 14CU GROUNDING
ELECTRODE CONDUCTOR AND
GROUND RODS PER CODE.
MAX 10 OHMS TO GROUND
REUSE EXISTING
PANEL AS J -BOX.
SCREW COVER WITH
SELF - TAPPING
SCREWS AND LABEL
AS J -BOX ONLY.
PROVIDE NEW S.E.
RATED PANEL BOARD.
INTERCEPT AND
EXTEND EXISTING
CIRCUITS AND
CONNECT TO NEW
BREAKERS,
PROVIDE ALL REQUIRED CUTTING AND PATCHING AS REQUIRED
TO COMPLETE THE WORK AS DESCRIBED ABOVE AND ON
DRAWINGS.
ROUTE CONDUIT EXPOSED ON OUTSIDE OF HOUSE. PROVIDE
STRUCTURAL SOUD 2X6 BLOCKING IN ATTIC FOR MAST.
PROVIDE BLOCKING AND UNISTRUT ASSEMBUES TO HOLD
CONDUIT AWAY FROM HOUSE SURFACE TO ALLOW FOR EXISTING
CONDITIONS. VISIT THE SITE TO ESTABLISH EXACT CONDITIONS
PRIOR TO BID.
NEW SERVICE DETA L
NOT TO SCALE
PROVIDE NEW SERVICE
DROP FROM POLE TO
HOUSE BY SCL. ALL
FEES PAID BY
CONTRACTOR.
PROVIDE NEW METER BASE,
RIGID STEEL MAST,
WEATHER HEAD AND
CONDUCTOR PIGTAILS PER
SCL REQUIREMENTS.
FINAL CONNECTIONS BY
SCL. INCLUDE ALL UTILITY
SERVICE FEES IN BID.
PROVIDE NEW WEATHER
HEAD, MAST GUYS AND
ANCHORS AT EXISTING
LOCATION. PROVIDE
NEW ROOF FLASHING.
METER AND FINAL
CONNECTIONS BY SCL.
INCLUDE ALL UTILITY
CHARGES IN BID.
TRIM VEGETATION TO
iz,/,--
PROVIDE MINIMUM 36"
CLEARANCE AROUND
SERVICE WIRES PER
SCL REQUIREMENTS.
RETAIN EXISTING PANEL BOX AND CONDUIT
FOR J -BOX. INTERCEPT AND EXTEND
EXISTING BRANCH CIRCUITING TO NEW
PANEL AS REQUIRED.
ANEL MP
ROUTE CABLE TO
NEW PANEL UNDER
EAVE, SIMILAR TO
EXISTING CONDITION
RECEIVED
APR 29 2011
PERMIT CENTER
ROOM
Appz I
MAIN FLOOR PLAN D
1/4" = 1'
S .M T i E
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 981.06
(206) 624 -2777 • FAX (206) 624 -2973
EN•INEERS. INC
frna ULM MIND MIR AM lin
gaeenn, ern a•ae+nrw
=PIM awl ell ewe
mot an a. we
0810.031 739
cc
0
a
J
0
H
z
w
H
z
z
0
U
0
Z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1739