Loading...
HomeMy WebLinkAboutPermit D11-120 - MADRONA SPECIALTY FOODS - OFFICE AND KITCHENMADRONA SPECIALTY FOODS 18300 CASCADE AV EXPIRED 12 -27 -I1 Dl 1 -120 City oikukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7888900175 Address: 18300 CASCADE AV TUKW Suite No: Project Name: MADRONA SPECIALTY FOODS DEVELOPMENT PERMIT Permit Number: D11 -120 Issue Date: 06/30/2011 Permit Expires On: 12/27/2011 Owner: Name: RIVERPOINT TWO LLC Address: PO BOX 20399 , SEATTLE WA 98102 Contact Person: Name: PAUL ENGERT Address: 130 LAKESIDE AV - SUITE 250 , SEATTLE WA 98122 Contractor: Name: SMAJIC CONSTRUCTION LLC Address: 12219 SE 65TH ST , BELLEVUE WA 98006 Contractor License No: SMAJICL954R2 Phone: 206 - 325 -2553 Phone: (206)419 -8090 Expiration Date: 12/22/2011 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT FOR NEW OFFICE AND TEST KITCHEN. THE CURRENT BUILDING SHELL HAS FLOORING, MECHANICAL, CEILING AND LIGHTING SYSTEMS IN PLACE. Value of Construction: $4,000.00 Fees Collected: $275.43 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0008 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 D11 -120 Printed: 06 -30 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature. I hereby certify that I have read an governing this work will be comp N N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and a ee to the conditions attached The granting of this permit does not construction or the perf •, nce of to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11 -120 Printed: 06 -30 -2011 7: All construction shall be done in confo with the approved plans and the requirem of the International Building Code or International Residential International Mechanical Code, Washingtdirate Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating doc: IBC -7/10 D11-120 Printed: 06 -30 -2011 and/or adding sprinlder heads. (IFC 901.4) • 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as duc s, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -120 Printed: 06 -30 -2011 CITY OF TUKWILA) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htq,://www.ci.tulcwila.wa.us Building Permit / No. I I Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** - SITE LOCATION Site Address: 18300 Cascade Ave Soth Tenant Name: Madrona Speciality Foods Property Owners Name: O'Keefe Companies, LLC Mailing Address: 18300 Cascade Ave. South King Co Assessor's Tax No.: 7888900175 Suite Number: (lD (l Floor: 1 New Tenant: Yes ❑..No Tukwila WA 98188 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Paul Engert - Lance Mueller & Associates Mailing Address: 130 Lakeside Ave Day Telephone: (206) 325 -2553 Seattle WA 98122 E -Mail Address: pengert @Imueller.com City State Fax Number: (206) 328 -0554 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: TBD Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: Same as contact above Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: N/A Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Porms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORNO'ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 4,000 Existing Building Valuation: $ 2,500,000 Scope of Work (please provide detailed information): Interior tenant improvement for new office and test kitchen. The current building shell has flooring, mechanical, ceiling and lighting systems in place. Will there be new rack storage? ❑ Yes J.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 0 *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 206 Compact: 206 Handicap: 14 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 26,812 940 0 0 V -B SPRNK B, 2nd Floor 26,812 0 0 0 V -B SPRNK B 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 0 *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 206 Compact: 206 Handicap: 14 Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: Paul Engert Mailing Address: 130 Lakeside Ave Date: 05/02/2011 Day Telephone: (206) 325 -2553 Seattle WA 98122 City State Zip Date Application Accepted: 5-)- -I, 1 Date Application Expires: i 1 -1- ll Staff Initials: H:\ApplicationsTorns- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.eov Parcel No.: 7888900175 Address: 18300 CASCADE AV TUKW Suite No: Applicant: MADRONA SPECIALTY FOODS RECEIPT Permit Number: D11 -120 Status: APPROVED Applied Date: 05/02/2011 Issue Date: Receipt No.: R11 -01357 Payment Amount: $168.70 Initials: JEM Payment Date: 06/30/2011 12:54 PM User ID: 1165 Balance: $0.00 Payee: SMAJIC CONSTRUCTION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2011 168.70 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 164.20 640.237.114 4.50 Total: $168.70 doc: Receiot -06 Printed: 06 -30 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 7888900175 Address: 18300 CASCADE AV TUKW Suite No: Applicant: MADRONA SPECIALTY FOODS RECEIPT Permit Number: D11 -120 Status: PENDING Applied Date: 05/02/2011 Issue Date: Receipt No.: R11 -00862 Initials: User ID: WER 1655 Payment Amount: $106.73 Payment Date: 05/02/2011 11:14 AM Balance: $168.70 Payee: LANCE MUELLER & ASSOCIATES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 28725 106.73 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 106.73 Total: $106.73 doc: Receipt -06 Printed: 05 -02 -2011 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential t Interior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised November 2010 Project Inf 001�� ..v. "'" P ass' °.ress 18300 cascade Ave South Date 5/2/2011 suite 160 For Buildi • :- : ... - it Use EV1EVvEp FO, CODE COMPLIAN APPROVED JUN 2 42011 Tukwila, 41A Applicant Name: Lance Mueller & Aeei =ociates Applicant Address: 130 Lakeside Ave Applicant Phone: 206 325 -2553 Project Description ❑ Pla: s'Included r: . uirere i° . e ❑ New Building ❑ Addition 4 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance S - �_�sti (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on p an oiVlslO Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed 4 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor plan/room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. DIN20 RECEIVED MAY 02 2011 TCENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT I 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised November 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA` (W /ft`) Use' LPA` (W /ft`) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments, restaurants /bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries5 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. •ERMIT COORD COPY a PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -120 DATE: 06/16/11 PROJECT NAME: MADRONA SPECIALITY FOODS SITE ADDRESS: 18300 CASCADE AV S, STE 160 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works ww\ &it ael -a t Fire Prevention S Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete *V1 Incomplete n DUE DATE: 06/21/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 07/19/11 Not Approved (attach comments) n DATE: Permit Center Use'Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PE PLAN REVIE • ING SLIP ACTIVITY NUMBER: D11 -120 DATE: 05 -02 -11 PROJECT NAME: MADRONA SPECIALTY FOODS SITE ADDRESS: 18300 CASCADE AV - SUITE 160 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: x,,11 S- L /WC . ilding i ision M lo-- �� bfic s INS AetA‘ti E O.,t I\0\- bc-� ire Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 05-03-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -31 -11 Not Approved (attach comments) IX- DATE: Permit Center Use Only II t CORRECTION LETTER MAILED: 1-)_ 1�' Departments issued corrections: Bldg ❑ Fire Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 06/15/2011 Plan Check/Permit Number: D11 -120 ❑ Response to Incomplete Letter # ▪ Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Madrona Speciality Foods Project Address: 18300 Cascade Ave South, Suite 160 Contact Person: Paul Engert Summary of Revision: Response to fire plan review comment by Al Metzler. Sheet Number(s): None - Letter only. Phone Number: (206) 325 -2553 RECEIVED CITY OF TUKWILA JUN 16.2011 PERMIT mania "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on �� //�l /er tf H:\Applications \Forms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 PA' City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director PAUL ENGERT 130 LAKESIDE AV - SUITE 250 SEATTLE WA 98122 RE: Permit No. D11 -120 MADRONA SPECIALTY FOODS 18300 CASCADE AV TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/27/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 12/27/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. DI 1 -120 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • LANCE MUELLER & ASSOCIATES A R C H I T E C TS June 15, 20111 Mr. Al Metzler Fire Project Coordinator City of Tukwila Fire Department A I A RE: Madrona Specialty Foods, Permit D11 -120 Mr. Metzler, • The purpose of this letter is to address you plan review comment. A copy of your plan review memo is attached for your reference. I asked the tenant to describe the use of their new test kitchen. Following is the response I received from the person who will be managing and using the facility Webb Girard. "The primary purpose of the test kitchen will be to replicate the products that we make in our production facilities. These include cookies, crackers, and hard candy. Both the cookies and crackers are baked while the candy is boiled. The equipment needed to replicate these functions are a convection oven for baking the cookies and crackers, and a stove top for the candy. All powered by electricity. The type of vapors given off by the cookies and crackers are those typically seen with normal baking operations while the vapors given off by the candy will be steam. I do not foresee any grease -laden vapors resulting from typical test kitchen use — such as those seen in commercial kitchens where cooks are constantly sauteing or frying food ". Hopefully this answers your question. If not, please call me at 206 325 -2553 and we will get the information you need. Thank you. Pa Engert , Architect Lance Mueller & Associates / Architects RECENED errs, GP rumut IJUN 16 2011 efiRtitifzeMarto CORRECTION 12_0 LTR# 1 130 Lakeside • Suite 250 • Seattle, WA 98122 • (206) 325 -2553 • Fax (206) 328 -0554 Architecture Planning Space Planning Interiors June 2, 2011 • City of f Tu%C1A/1lc2 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Paul Engert Lance Mueller & Associates 130 Lakeside Av, Suite 250 Seattle, WA 98122 RE: Correction Letter #1 Development Permit Application Number D11 -120 Madrona Speciality Foods —18300 Cascade Av S Dear Mr. Engert, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building, Planning, and Public Works Departments have no comments. Fire Department: Al Metzler at 206 575 -4407 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, c Bill Rambo Permit Technician encl File No. D11 -120 W:\Permit Center\Correction Leners\2011\D11 -120 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Fire Prevention Bureau Alan Metzler, Fire Project Coordinator Fire Prevention Bureau Review Memo Date: Project Name: Address: Permit #: Plan Reviewer: May 10, 2011 Madrona Specialty Foods 18300 Cascade Av S — Suite 160 D11 -120 Al Metzler, Fire Project Coordinator The Fire Prevention Bureau conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. 1. The plans and scope of work indicate the creation of a test kitchen. What type of cooking will take place in the test kitchen? Will there be any cooking that produces grease -laden vapors? Should there be questions concerning the above requirements, contact the Fire Prevention Bureau at 206 - 971 -8718. No further comments at this time. Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SMAJIC CONSTRUCTION LLC UBI No. 602566567 Phone 2064198090 Status Active Address 12219 Se 65Th St License No. SMAJICL954R2 Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 12/22/2005 State WA Expiration Date 12/22/2011 Zip 98006 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date SMAJIC, ADNAN Partner /Member 12/22/2005 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG4819 12/15/2005 Until Cancelled $12,000.00 12/22/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 CBIC C11SG4819 12/15/2010 12/15/2011 $1,000,000.00 11/08/2010 2 CBIC C11SG4819 12/15/2007 12/15/2010 $1,000,000.00 10/28/2009 1 CBIC C11SG4819 12/15/2005 12/15/2007 $1,000,000.00 10/09/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https:// fortress .wa.gov /lni/bbip/Print.aspx 06/30/2011 co 0 Cascade Ave. South West Valley Hwy AREA OF WORK THIS PERMIT FIRST FLOOR FILE COPY Permit No., V ' 0/0 Plan review approval is subject to errors and omissions, Approval of construction documents does not authorize the violation of any adopted code or ordinance. Reccipt of approved Field r ns is acknowledged: BY Date. CI Of kwIla BUILDING DIVISION SITE PLAN NORTH " _ 1 50 GENERAL NOTES VICINITY PLAN NORTH NO SCALE DEFERRED SUBMITTALS 1. PLUMBING WORK UNDER SEPARATE PERMIT 2. MECHANICAL WORK UNDER SEPARATE PERMIT 3. FIRE SPRINKLER WORK UNDER SEPARATE PERMIT SEPARATE r I 4iT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping Cat of Tukwila IL DING DIMMS YN 1. REFER TO BASIC BUILDING SHELL SPECIFICATIONS AND STANDARDS FOR EXISTING SHELL CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECTS APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 16 GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. D OTHERWISE. 11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. 13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 14. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARD OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT FOUR (4) COPIES OF COMPLETE BACK -UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 15. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. 16. MECHANICAL. AND ELECTRICAL FIXTURES, OUTLETS, ETC. WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 17. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S & TENANT APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES, AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, FIRE EXTINGUISHERS AND HOSE CABINETS ETC. 18. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY ARCHITECT & TENANT. 19. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 114" IN 10 " -0 ". THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 20. FLOOR FINISH TRANSITIONS SHALL OCCUR UNDER DOORS, UNLESS SHOWN OR NOTED OTHERWISE. REVISIONS No changes shall he made to the scope of work without prior approval of Tulywila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 tenant improvement Madrona Speciality Foods 18300 Cascade Avenue South Suite 160 Tukwila WA PROJECT NOTES TAX LOT NUMBERS: 7888900170 - NORTH BUILDING 18200 CASCADE AVE. SOUTH 7888900175 - SOUTH BUILDING 18300 CASCADE AVE. SOUTH LEGAL DESCRIPTION: SOUTHCENTER SOUTH INDUSTRIAL PARK LOTS 15 & 17 BEGINNING SW CORNER LOT 17 THEN S 78° 36' 10" E 80 FEET THEN ALONG CURVE TO RIGHT CENTER BEARING N 11° 23' 50" E ALONG A LINE 30 FEET E OF & PLW W/ LINE LOT 17 DISTANCE OF 357 FEET TO TPOB THE CONTG N 11d 23' 50" E ALONG SAID LINE RADIUS 50' ARC DISTANCE 78.54 FEET THRU C/A OF 90° 00'00" THEN N 11° 23' 50" E ALONG SAID LINE 291.25 FEET THEN ALONG CURVE TO LEFT RADIUS 110 FEET THRU C/A OF 62D 57' 52" ARC DISTANCE OF 120.83 FEET THEN N 11° 23' 50" E ALONG A LINE 30 FEET W OF & PLT W LINE OF LOT 17 147.375 FEET TO THE TOP OF RIGHT BANK OF GREEN RIVER THEN ALIGN SAID TOP OF RIGHT BANK OF GREEN RIVER TO THE FOLLOWING COURSES AND DISTANCES S 44° 29' 00" E 9632 FEET S 59° 43' 00" E 98.00 FEET S 72° 17' 00" E 101.00 FEET 5 82° 08' 00 "E 100.00 FEET N 78° 54' 00 "E 99.00 FEET N 68° 34' 00" E 99 FEET N 73° 00' 33" E 97.69 FEET M /L/ TO W/ MARGIN OF SECONDARY STATE HIGHWAY 2M THEN LEAVING SAID TOP OF RIGHT BANK OF GREEN RIVER ALONG SAID W. MARGIN ON A CURVE TO RIGHT OF THE CENTER BEARING N 47° 33' 20" W RADIUS OF 543.14 FEET ARC DISTANCE 87.08 FEET THRU C/A OF 90° 11' 11" THEN S 51° 37' 10" W 131.40 FEET THEN ALONG CURVE TO LEFT ON SAID W. MARGIN RADIUS OF 603.14 FEET ARC DISTANCE OF 423.53 FEET THRU C/A OF 40° 14' 10" THEN S 11° 23' 50" W 23.32 FEET THEN N 78° 36' 10" W 295.00 FEET TO TPOB - AKA PHASE II OF CORPORATE PROPERTY INVESTORS BINDING SITE IMPROVEMENTS PLAT RECORDING NO. 810421010455 & CITY OF TUKWILA BOUNDARY LINE. ZONE: SITE AREA: CONSTRUCTION TYPE: BUILDING AREA: NORTH BUILDING NO. STORIES SOUT`H'sBUILDING "NO. STORIES PARKING REQUIRED: PARKING PROVIDED: CODES USED: TENANT AREA: OCCUPANCY: OCCUPANT LOAD: TENANT:. C / CU 6.58 ACRES V -B FIRE SPRINKLERED 53,625 2 53,625 2 278 STALLS 414 STALLS 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL FIRE CODE 2009 WASHINGTON STATE ENERGY CODE 2009 WASHINGTON STATE BUILDING CODE 2009 PLUMBING CODE 2009 MECHANICAL CODE 2003 ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES 940 USEABLE SQ. FT. B - OFFICE 100 SQ. FT. /OCCP. 940 1 100 = 9 OCCUPANTS MADRONA SPECIALITY FOODS SCOPE aF WORK: INTERIORTENANT IMPROVEMENT ON THE FIRST FLOOR TOTALING 940 SQ. FT. THE WORK CONSISTS OF ADDING A NEW WALL AND DOOR. CHANGING THE EXISTING 2 X 4 LIGHT FIXTURE LOCATIONS IN THE EXISTING SUSPENDED CEILING GRID. THE CURRENT BUILDING SHELL SPACES HAVE COMPLETE SUSPENDED ACOUSTICAL TILE CEILING AND LIGHTING SYSTEMS. BUILDING REPRESENTATIVE: ARCHITECT: GENERAL CONTRACTOR: O'KEEFE COMPANIES 18300 CASCADE AVE SOUTH TUKWILA, WA 98188 T. (206) 236 -6200 CONTACT: TOM O'KEEFE EMAIL: tom @odc2.com LANCE MUELLER & ASSOCIATES 130 LAKESIDE AVE SEATTLE, WA 98122 T. (206) 325 -2553 F. (206) 328 -0554 CONTACT: PAUL ENGERT EMAIL: pengert @Imueller.com SMAJIC CONSTRUCTION, LLC 12219 SE 65th STREET BELLEVUE, WA 98006 T. (206) 419 -8090 F. (425) 378 -2593 CONTACT: ADI SMAJIC EMAIL: smajic @msn.com INDEX OF DRAWINGS TA1.1 COVER SHEET / SITE PLAN TA1.2 LEGENDS / SYMBOLS 1 DOOR TYPES TA2.1 1/16" OVERALL BUILDING 1 EGRESS PLANS TA2.2 118" FLOOR -1 - EAST FLOOR PLAN TA3.1 1/8" FLOOR -1 - EAST CEILING PLAN TA4.1 CEILING DETAILS / NOTES / WALL TYPES REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 2011 City o 'T iia BUILDING • SION EX DEC 27 2011 RECEIVED MAY 022011 PERMITCENTER o CC PERMIT SUBMITTAL C .0 0 711 -080 job no. P. ENGERT drawn P. ENGERT checked T 01 Q 0) CU DEC 27 2011 RECEIVED MAY 022011 PERMITCENTER DOOR / RELITE TYPES 2' -0" W. 3' -0" Oa BLDG. STD. SOLID CORE WOOD DOOR BLDG. STD. HOLLOW METAL FRAME 1/4" TEMPERED GLASS 3' -0" 1 fii BLDG. STD. SOLID CORE WOOD DOOR BLDG. STD. WOOD FRAME 3'-0" 8" 2' -0" BLDG. STD. SOLID CORE WOOD DOOR BLDG. STD. WOOD FRAME 114" TEMPERED GLASS WOOD SUITE ENTRY DOOR & HOLLOW METAL FRAME W/ SIDELITE HARDWARE GROUPS WOOD DOOR AND WOOD FRAME 1. LEVER LOCK SET (SUITE ENTRY FUNCTION) HINGES SILENCERS CLOSER WALL STOP 2. LEVER LATCH SET HINGES WALL STOP SILENCERS 3. LEVER LOCK SET HINGES WALL STOP SILENCERS 4. PUSH / PULL HINGES CLOSERS SILENCERS 5. LEVER LOCK SET PANIC DEVICE HINGES CLOSER WOOD DOOR AND WOOD FRAME W/ SIDELITE ABBREVIATIONS ADJ ALT AFF ALUM L ANOD. ACT BLDG. BLK'G. BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FF FIN FLR FLUOR FOIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FACTORY FINISH OR FINISH FLOOR FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FT FOOT /FEET FTIC FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURN FURNISH / FURNISHINGS GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JAN JB JST JT KIT LF LTG MAT'L MAX MECH MED MEZZ MFR MISC MTD M11 N/A NIC NO NOM NTS OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERMO TYP VAR VCT VERT VWC WI W/0 WC WO JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL VARIES VINYL COMPOSITION TILE VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD GRAPHICS SYMBOL LEGEND II —I 1 17=-1 I 11=111=111= EARTH GRAVEUROCK CONCRETE ASPHALT PAVING WOOD FRAMING BLOCKING OR SHIM FINISH WOOD PLAN SYMBOLS iiiill!!e: ? =i i!i!i!i!i!i!i!i / / / / /// GLASS(ELEVATION) GLASS(SECTION) GYPSUM WALL BOARD CAULKING /SEALANT PLYWOOD BRICK ACOUSTIC TILE RIGID INSULATION BATT INSULATION METAL INTERIOR ELEVATION SYMBOL ELEVATION NUMBER SHEET NUMBER ELEVATED WALLS (SHADED AREAS) DETAIL SHEET NUMBER SECTION SHEET NUMBER DETAILS BUILDING SECTIONS ENLARGED I PLANS ` - - - OFFICE 105 COLUMNS OR GRID LINES ROOM NAME & NUMBER REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 2011 City of Tukwila BUILDING DIVISION DOOR NUMBER (EX. = EXIST. TO REMAIN) FRAME TYPE RATING (MINUTES) HARDWARE GROUP (EX. = EXIST. TO REMAIN) WALL TYPE DEMO. PLAN LEGEND SYMBOL DESCRIPTION ALL ITEMS SHOWN IN SHADED LINETYPE ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE EXISTING WALL, DOORS, ETC. TO BE REMOVED EXISTING SUSPENDED CEILING GRID TO BE REMOVED EXISTING 2x4 LIGHT FIXTURES TO BE REMOVED /RELOCATED FLOOR PLAN LEGEND SYMBOL DESCRIPTION EXISTING WALL TO REMAIN NEW WALL PER FLOOR PLAN SOUND OR THERMAL INSULATED WALL PARTIAL HEIGHT WALL PER FLOOR PLAN ELECTRICAL LEGEND SYMBOL FIXTURE DUPLEX OUTLET FOURPLEX OUTLET DEDICATED DUPLEX OUTLET DEDICATED FOURPLEX OUTLET CE TIMER DEDICATED ELECTRICAL OUTLET WI TIMER Q FAX DEDICATED FAX OUTLET e COMPUTER / VOICE OUTLET -� ELECTRICAL JUNCTION BOX ELECTRICAL POWER POLE LOCATION SYSTEMS FURNITURE BASE POWER FEED (COORDINATE W/ FURNITURE SUPPLIER) 0 GFI LB El DUPLEX OUTLET W/ GROUND FAULT PROTECTION FLOOR DATA BOX - FINAL LOCATIONS TO BE VERIFIED W/ TENANT PRIOR TO CORING FLOOR ELECTRICAL BOX - FINAL LOCATIONS TO BE VERIFIED W/ TENANT PRIOR TO CORING CABLE TV OUTLET SECURITY ACCESS POINT/ CARD READER CEILING PLAN SYMBOLS SYMBOL FIXTURE NEW 2' X 4' ACOUSTICAL LAY -IN CEILING PANELS WITH %" HEAVY DUTY SUSPENDING GRID SYSTEM NEW 2 x 4 RECESSED FLUORESCENT LIGHT FIXTURE NEW 6" DIA. COMPACT FLUORESCENT LIGHT FIXTURE O NEW 6" DIA. COMPACT FLUORESCENT WALL WASH LIGHT FIXTURE $3 LIGHTED EXIT SIGN DIRECTIONAL (AS SHOWN ON CEILING PLAN) WALL LIGHT SWITCH THREE WAY LIGHT SWITCH EX ED DEC 27 2011 D RECEIVED MAY 022011 PERMIT CENTER CID C w O L cLE 412a., c ca C co ci c!) L a) O U (/) 0) as O < O) 1 U 0 as c ▪ co . o0 ca cD 1— a— Tr) Cs -0 Vs PERMIT SUBMITTAL C 0 y 0 c 711 -080 job no. P. ENGERT drawn P. ENGERT checked a 0 0 a CID C w O L cLE 412a., c ca C co ci c!) L a) O U (/) 0) as O < O) 1 U 0 as c ▪ co . o0 ca cD 1— Al harfoon...........,,rrmoomoonoffoff rr JNJr rA%AL • 4YJn rNr j7 I �i •- ifr f ii ii ii. YuaravoY.omm / k i G .4 <� 3 6 •r I-;N „, rr.,:t,,,,,,,,,N,,,,,,N,,,,,,N. NN,r„ 27 -11' 1 1474.7.:404,..44001 4 P 'I (.71-0\1 /1/ 12/ 27-0' 27-0' 270 27-0' /4 .4 27-0' 27-0' 27-0' 27-0' r,_,_, lrfNr/}ryrrJr rN r p,,NfJJNf rkff noun 1HrNNNr ffNmlVrAmeer.rN_MSi r NINrF _ -r �F:r:” -HJr rF ii t :4 xrrrrxr._ it -rrrrc 1 iir^.... 't> > 4 111 PS 1j •`� i r1 FIX PEI FEC 1.-ZA rNirrrMSWISViNNNNN I N rrHiHH!NH,rr N rrrN% MY:Yrrirrrrmr. EGRESS PATHW ,�44N:rrY+N4:4Y .V.GwrrHY.Y.A4Yd�.GYJMY.G4•MY x {:r r••-- rrr -r - -rr _- _n- v- _- r -_ -nrr rr f x. /7r 0 j . „,,,,,,, .v 911/4Nir!riNH N r'r L:i-NiiAiNN 27 -1/' / ,.,NN N„ir „rr1.16.5,rNN„ /, HNN ASVI4Sii ASMFAWIWAVA6::546W, iii, i /,iNiNriiiiNii _•rm_: ri, NiiNNSrNNN,Nr,NriNNN,Nr,.'lr:rr N. 22' -11' 22 -11' FLOOR -2 OVERALL PLAN 1/16” =1' -0" 61 AREA OF WORK THIS PERMIT r/Air Ir P iC2! ff4N1NJlIfNNNNNNNAVAMO IN- f IJ_JNIf /IflJJ- HJJNffIrJJJ flrllrr•rt r -r r- WHNf F -- - y 1 �R- ii :rrrrrrr. NN.Yr�.Y ” ,.YNtiYrN�N� N.r�NNN 13r ' �.4_ ,' A 4 L { Abe LI- h; N Nr,N N r r. ,,NN r r H r r r r N N N i Ni i v.. i r r r N ii v mnt 7,:;;;;;;;r* ......... E► IT N„rr „rrr,,,,.yri;_.nF..w., Nrr. ' Nole.NSV REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 2011 City of Tukwila BUILDING DIVISION CODE SUMMARY: OCCUPANCY: EXITS REQ'D. EXITS PROVIDED EXIT WIDTH PROVIDED B OCCUPANT LOAD = 11100 SQ. FT. 940 SQ. FT. / 100 SQ. FT. = 9 OCCUPANTS 1 MAXIMUM TRAVEL DISTANCE TO EXIT BUILDING - 300' (FIRE SPRINKLED BLDG.) EXISTING BUILDING CORRIDORS ARE NOT REQUIRED TO BE RATED CONSTRUCTION PER TABLE 1018.1 COMMON PATH OF TRAVEL DOES NOT EXCEED 100' 36” SY \,... STORAGE I LOBBY' — J EXIT FEE': v Y/% Y/. r~' EXIT aVir r ri �NNNN..e34554, L. Of FLOOR -1 OVERALL PLAN 1/16 =1' -0" ALL WORK IS LIMITED TO THE FIRST FLOOR EXPIRED DEC 272011 p ii -110 RECEIVED MAY 022011 PERMIT CENTER lam c CLD Q) Cii OL E .Fr c ICI ca CI g--Dc CD C.0 O 0) L N O U u) — w c Q 0_ N - L- 0 U 0 a c ca .oU co n' lc— O CO PERMIT SUBMITTAL C O .y ci 11 -080 job no. P. ENGERT drawn P. ENGERT checked a 0 8 v lam c CLD Q) Cii OL E .Fr c ICI ca CI g--Dc CD C.0 O 0) L N O U u) — w c Q 0_ N - L- 0 U 0 a c ca .oU co n' 0 io c1 -1" z TEST KITCHEN 102 22' -11" OFFICE 101 UP 22' -10" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 2011 City of Tukwila BUILDING DIVISION { F 1 FEC CORRIDOR •E J it 22' -10" } RECEPTION (101; A :AN.1 ELEC. PANTRY. 104.1 STORAGE ELEV. MACH. /7 ELEV.. /, / LOBBY • 7' - -. 1. D UP t:7 HALL 11.104) -4£ CE k tE tEi: BREAK ROOM 1053 l E EC. ROOM 0 22' -10" 22' -10" F 22' -11" FLOOR -1 EAST PLAN 1/8" =1' -0" D11- l2-0 DEO 7 2011 RECEIVED MAY 022011 PERMITCENTER 0 c co as LOOR -1 EAST PLAN 0) LW 4 U r0 u� 0] Q LL W 1 1 W 3 w 0 z Q J N CO • sheet TA2.2 05/02/11 1 CD co MP PERMIT SUBMITTAL 0 .S ED_ d 11 -080 job no. P. ENGERT drawn P. ENGERT checked. 0 B 0 c co as LOOR -1 EAST PLAN 0) LW 4 U r0 u� 0] Q LL W 1 1 W 3 w 0 z Q J N CO • sheet TA2.2 GENERAL NOTES 1. EMERGENCY EGRESS LIGHTING IS NOT REQUIRED WITHIN TENANT SPACE AS OCCUPANCY LOAD IN LESS THAN 50 OCCUPANTS. . SUSPENDED CEILING SYSTEM IS EXISTING THROUGHOUT THE SPACE. SEE SHEET TA3.1 FOR NOTES REGARDING ANY CHANGES OR ALTERATIONS TO SYSTEM. 3. EACH ROOM OR SPACE TO HAVE SEPARATE LIGHTING CONTROL WITH OCCUPANCY SENSOR IN ACCORDANCE WITH 2009 WASHINGTON STATE ENERGY CODE SECTION 1513. ti F T ; 5 a -.r a- 0 F- `544554 v t4 •544 t ... : T f .. .5 w r� �t 1 :.. ... `I ' .t4 t 44 p r yam..• .1: •.�,.:...... N 4 MO? . —-I, r .:.:.: ....'' M • 5].. si t � •i t. -- .,... f f f ..,:r.: :. ..... '' -. .... e ? � . F :4. r E— �\ -,. i . ci 11 -080 job no. P. ENGERT drawn P. ENGERT checked a 0 0 a, CO v I t AV t45t54, .. ; e.. s a- 0 v �t �5 PERMIT SUBMITTAL C 0 0) N 44 -,. i -e", ci 11 -080 job no. P. ENGERT drawn P. ENGERT checked a 0 0 a, CO v I AV t45t54, Illir IN iGG "117"'-='y_:- - :_ ;ref . .». .t•...: ..,t:, .•,,,,, • . �. ..: �. : r's4 •t4 f � t•4 tt4 EBI,ttl 4 .cu "0 DL :E.. ii ELEV. MACK ELEV. • REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 Z011 City of Tukwila BUILDING DIVISION ..7:b^. -.. �D DEC 212011 RECEIVED FLOOR - 1 EAST CEILING PLAN MAY 022011 1/8" =1' -0" P RMI! CEN MGR bW-lZO O (.l) Q) o O 0ci) Ii .CD aj c EWW o<D) > - -w:c 2 = U co as E C c -6U c a) > F— OMNI (206) 325-2553 • z 0 Z_ 1 w 0 co w 0 0 sheet TA3.1 a- 0 v PERMIT SUBMITTAL C 0 0) N ci 11 -080 job no. P. ENGERT drawn P. ENGERT checked a 0 0 a, CO v O (.l) Q) o O 0ci) Ii .CD aj c EWW o<D) > - -w:c 2 = U co as E C c -6U c a) > F— OMNI (206) 325-2553 • z 0 Z_ 1 w 0 co w 0 0 sheet TA3.1 IF HANGER WIRE IS OUT OF PLUMB GREATER THAN 1:6 COUNTER SPLAY PER ASTM C636 WALL WHICH PENETRATES CEILING GRID WALL EDGE MOLDING MAX. 8" ii #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE @ EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY MIN. 2" MIN. 3/4" @ UN- ATTACHED WALLS EDGE BRACING CEILING SEISMIC BRACING TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID #12 HANGER WIRE ANCHORED TO — STRUCTURE ABOVE SEISMIC JOINT CLIP EXPANSION SLEEVE CEILING EXPANSION JOINT WALL EDGE MOLDING CROSS TEE PER ASTM C635 STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART @ UNATTACHED WALLS ONLY EDGE BRACING ISOMETRIC STEEL STUD COMPRESSION POST ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION #12 HANGER WIRE TYP. TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" TOP TO BOTTOM) REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 4 2011 City of Tukwila BUILDING DIVISION CROSS TEE PER ASTM C635 MAIN CEILING BEAM PER ASTM C635 CEILING GRID SEISMIC BRACING NO SCALE SUSPENDED CEILING ARE TO COMPLY WITH THE FOLLOWING CODES AND REGULATIONS: A. 2009 INTERNATIONAL BUILDING CODE (IBC) SECTION 803.9 B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C635 AND ASTM C636 (REFERENCED IN IN 803.9). C. ASCE (AMERICAN SOCIETY OF CIVIL ENGINEERS) 7 SECTION 9.6.2.6 D. CISCA (CEILING & INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION) RECOMMENDATIONS FOR SEISMIC ZONES 3-4 REFERENCED IN ASCE - 7 SECTION 9.6.2.6.2.2 E. IBC 102.1 STATES "WHERE IN ANY SPECIFIC CASE, DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT MATERIALS, = METHODS OF CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE APPLICABLE ". F. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: • ONLY A HEAVY DUTY T -BAR GRID SYSTEM SHALL BE USED. ASTM - 7 SECTION 9.6.2.6.2.ITEM A. • WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE (WALL ANGLE ) SHALL BE NOT LESS THAN 2 INCHES. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM B. • ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL ANGLE. POP RIVETS ARE ACCEPTABLE. ON THE OTHER TWO SIDES, THERE SHALL BE A/4" INCH CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. ASTM -7 SECTION • STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND OR CROSS TEES. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR ALL EDGES . CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 4. • VERTICAL HANGERS SHALL BE NO. 12 GAGE WIRE SPACED AT 4' -0" ON CENTER OR NO. 10 GAGE WIRE SPACED AT 5' -0" ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED WITHIN 1:6 OUT -OF -PLUMB UNLESS COUNTER - SLOPING WIRES ARE PROVIDED. • LATERAL BRACING IS REQUIRED. SPLAY WIRES PODS AT 12" MAX. O.C. AND 6'-O" MAX. FROM WALLS. INSTALL TRULY COMPRESSIBLE (E.G. SPRING LOADED) STRUTS OR NO STRUTS AT ALL. RIGID STRUTS ARE NOT ALLOWED. CISCA GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY 2004, INSTALLATION SECTION, ITEM 3. • CEILINGS OVER 2500 SQ . FT. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT WALLS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SQ. FT. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM D. • FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS SHALL HAVE A 2 INCH OVERSIZE RING, SLEEVE OF ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF A LEAST 1 INCH IN ALL DIRECTIONS; OR SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM E. • CHANGES IN CEILING PLAN ELEVATIONS SHALL BE PROVIDED WITH POSITIVE BRACING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM F. • CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUSPENDED INDEPENDENTLY FROM THE CEILING. ASTM - 7 SECTION 9.6.2.6.2.2 ITEM G. EX'1ED bE(,272011 ATTACH 2 Y" x 20 GA. METAL STUDS BRACES TO TOP TRACK W/ (2) - METAL FRAMING SCREWS • A a 2 Y" x 20 GA. METAL STUDS BRACES @ 8'-O" O.C. (ALTERNATE DIRECTIONS) AT ALL WALL LOCATIONS OVER 12-0" LONG. ATTACHED TO WOOD FLOOR STRUCTURE ABOVE MAKE NO ATTACHMENT OF WALL TO CEILING GRID SYSTEM EXIST. ACOUSTICAL TILE CEILING 2Y" SOUND INSULATION PER FLOOR PLAN 2z" x 25 GA. METAL STUDS @ 24" O.C. WITH %" TYPE "X" GWB EACH SIDE y8" DIA. POWDER ACTUATED FASTENERS @ 24" O.C. TYP. 4" RUBBER BASE EXIST. CONCRETE SLAB ON GRADE bi ■iio RECEIVED MAY 022011 PERMIT CENTER TYP. OFFICE PARTITION @ FLOOR -1 1/2" =1' -0" c U co z V) c° a ,i c o ca Q a' a, 0 co CO C CQ - o0 C p_- O ▪ co N M 05/02/11 1 m PERMIT SUBMITTAL 1 0 0 y, 'S 0 1IMII11 -080 7ob no. P. ENGERT drawn P. ENGERT checked a I) o 0 07 c U co z V) c° a ,i c o ca Q a' a, 0 co CO C CQ - o0 C p_- O ▪ co N M