HomeMy WebLinkAboutPermit D11-126 - PROFESSIONAL PLASTICS - RAMPPROFESSIONAL
PLASTICS
6233 SEGALE PARK
DR D
Dl 1 -126
City Aukwila
� S
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
1
DEVELOPMENT PERMIT
Parcel No.: 3523049112
Address: 6233 SEGALE PARK DR D TUKW
Suite No:
Project Name: PROFESSIONAL PLASTICS
Permit Number: D11 -126
Issue Date: 05/16/2011
Permit Expires On: 11/12/2011
Owner:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contact Person:
Name: BARRY BENNETT
Address: PO BOX 88028 , TUKWILA WA 98188
Contractor:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contractor License No: SEGALPL902CO
Phone: 206 - 396 -2012
Phone: 206 - 575 -2000
Expiration Date: 04/01/2012
DESCRIPTION OF WORK:
CONSTRUCT CONCRETE DRIVE IN RAMP.
Value of Construction: $15,000.00 Fees Collected: $622.10
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009
Type of Construction: III -B Occupancy per IBC: 0008
Electrical Service Provided by: PUGET SOUND ENERGY
* *continued on next page **
doc: IBC -7/10
D11 -126 Printed: 05 -16 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
N
N
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
Date: t ItO 1
I hereby certify that I have read and ned this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie • whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
to this permit. ,.: 2
Signature: . -- Date: 6' //
Print Name: `T NNL— -
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any
requirements for special inspection.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-126 Printed: 05 -16 -2011
this requirement.
• •
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors m the construction documents and other data.
doc: IBC -7/10
D11 -126 Printed: 05 -16 -2011
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
(Sk'DE LOCA'IPI
Site Address: 6233 Segale Park Drive D
Tenant Name: Professional Plastics
Property Owners Name: Segale Properties LLC
Mailing Address: PO Box 88028
King Co Assessor's Tax No.: 352304 -9112
Suite Number: N/A Floor: Ground
New Tenant: m Yes ❑ ..No
Tukwila
City
WA
State
98138
Zip
TAC PERS
o we,contaei
'our permit Isgready otbe &z.ssue
Name: Barry Bennett
Mailing Address: PO Box 88028
E -Mail Address: Bbennett@segaleproperties.com
Day Telephone:
Tukwila
(206) 396 -2012
WA
City State
Fax Number: (206) 575 -1662
98138
Zip
ENERALCONTRACT
ontractor ;l of ormation for
RINFURMATION.
ech ical (pg4),forWP
Company Name: Segale Properties LLC
Mailing Address: PO Box 88028
Contact Person: Barry Bennett
E -Mail Address: Bbennett @segaleproperties.com
Contractor Registration Number: SEGALPL902CQ
Tukwila WA
City State
Day Telephone: (206) 396 -2012
Fax Number: (206) 575 -1662
98138
Zip
Expiration Date: 04/01/2012
A`
RCHITECT 3
OF RECORD Alltplansrmust\be stamped
yy
iitecfof.7
Company Name: Lance Mueller and Associates
Mailing Address: 130 Lakeside Suite 250
Contact Person: Harold Christensen
E -Mail Address: HaroldC @Imueller.com
Seattle
City
WA
State
Day Telephone: (206) 325 -2553
Fax Number: (206) 328 -0554
98122
Zip
ENGINERS OF BT;CORD'�
ans muyst�ybestamp
3 u
neer, ofi
Company Name: Engineers Northwest
Mailing Address: 6869 Woodlawn Avenue NE
Contact Person: Dale Kaemingk
E -Mail Address: DaleK @engineersnw.com
H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Applicetion.doc
Revised: 7 -2010
bh
Seattle WA
City State
Day Telephone: (206) 525 -7560
Fax Number: (206) 522 -6698
98115
Zip
Page 1 of 6
DING
RMATIC
Valuation of Project (contractor's bid price): $ 15,000.00 Existing Building Valuation: $
Scope of Work (please provide detailed information): Construct concrete drive in ramp.
Will there be new rack storage? ❑ Yes
O.. No If yes, a separate permit and plan submittal will be required.
'Iti$1ui1d
easdneS
ommy
luareil
oe struction:per
154,580
0
640
3N
S -2, B
k2 ".° FIaoi'
Floors "'
Basemen
ccessoi
Structur333333333*77f3f3f3f3n
i3j 33 3 3i 3i3k3i773i'3
Attached'Garag
ad;Garaj
*Attached,
IDetacuuur3n Carpia
-Namur
A33N3r3,�.,
Covered Deck'''
,Uncovered=
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: 46 Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
m Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Fomu- Applications On Line\2010 Applications \7-2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 2 of 6
ITAPDICAITION NOT
•
thcableto a
•
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: B
Mailing Address:
Bennett
PO Box 88028
IDate Application Accepted:
Day Telephone:
Tukwila
City
Date: 5 -2 -11
206 - 396 -2012
WA
State
98188
Zip
Date Application Expires:
Staff Initials:
H: Wpplications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc
Revised: 7 -2010
bh
Page 6 of 6
. .
wqs City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
ParcelNo.: 3523049112 Permit Number: D11 -126
Address: 6233 SEGALE PARK DR D TUKW Status: PENDING
Suite No: Applied Date: 05/04/2011
Applicant: PROFESSIONAL PLASTICS Issue Date:
Receipt No.: R11 -00891
Payment Amount: $622.10
Initials: BLH Payment Date: 05/04/2011 01:04 PM
User ID: ADMIN Balance: $0.00
Payee: SEGALE PROPERTIES
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 629842 622.10
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $622.10
374.30
243.30
4.50
doc: Receipt -06 Printed: 05 -04 -2011
" " '
• . .
INSPECTION:RECORtil
Retain a copy with permit tiCI-12-Cdo
IN ECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
P■10Cr-es$IONIA L.
Type of Inspection:
(---.1KIAL-
(`‘,,i,./..,_v t es.4 e i
Address:
(-/,? a .sF cp.v. PAR'
Date Called:
n
Special Instructions:
Date Wanted:
7-5-11
aicr:
Requester:
Phone No:
aD( 0-31,.. -Ogg
1J Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
(`‘,,i,./..,_v t es.4 e i
. , /..) A (
. .
. .
t
Date: -
\- -
NSPECTION FEE REQUI D. Prior to r13t inspection. fee niustp.e.
• .,.
. •
d at 6300 Southcenter Blvd.. Suite 100. Call to schedule ieinspetfilin.. •'.
• .. , •
• -...?
• • _
• :
"��:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pro'ect:
-PI sKi
1 a c e - 5 5 ■ o a > , r ► + . I n c
Type of Inspection:
-- b&T t t^3 4s
-
Address:
(0A-3 44(00+4_ Petal)
Date Called:
Special Instructions:
Date Wanted:
(� -1— t\
a.m`
m.
Requester:
Phone No:
0062 -- b1L.-1 ?Piy
proved per applicable codes. Corrections required prior to approval
COMMENTS:
i s pec , r:
REI
pai
•
•
.
1 - 1 a
SPECTION FEE REQ ED. Prior to text inspection. fee must be' . ' .'
at 6300 Southcenter Blvd.. Suite 100, all to schedule reinspectiori:
• •
PE T
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: 011 -126 DATE: 05 -04 -11
PROJECT NAME: PROFESSIONAL PLASTICS
SITE ADDRESS: 6233 SEGALE PARK DR D
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
5-441-l\
Lidding vision tanning Division
g �_ ), Sr Ire Prevention ,.i,
Pu tic Works r� Structural
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 05-05-11
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions ❑
Notation:
REVIEWER'S INITIALS:
DUE DATE: 06-02-11
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
i I III
F625- 052 -000 (8/97)
DEPARTMENT OF LABOR Al! rp:.D
REGISTERED AS PROVIDED BY LAW A
CONST CONTR GENERAL
REGIST. # EXP. DATE
CCOI SEGALPL902CQ 4/1/2012
EFFECTIVE DATE 2/18/2010
SEGALE PROPERITIES LLC
PO BOX 88028
TUKWILA WA 98138 -2028
Contractors or Tradespeople Per Friendly Page
1
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name SEGALE PROPERITIES LLC UBI No. 602023533
Phone 2065752000 Status Active
Address Po Box 88028 License No. SEGALPL902CQ
Suite /Apt. License Type Construction Contractor
City Tukwila Effective Date 2/18/2010
State WA Expiration Date 4/1/2012
Zip 981382028 Suspend Date
County King Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
LAPIALP055MZ
LA PIANTA LIMITED
PARTNERSHIP
Construction
Contractor
General
Unused
7/9/1995
4/1/2001
Archived
SEGALBP151M5
SEGALE BUSINESS
PARK
Construction
Contractor
General
Unused
7/25/1985
7/9/1995
Archived
LAPIAL•008J8
LA PIANTA LLC
Construction
Contractor
General
Unused
4/28/2000
4/1/2010
Inactive
Business Owner Information
Name
Role
Effective Date
Expiration Date
SEGALE, MARIO A
Agent
02/18/2010
Amount
SEGALE, MARIO A
Partner /Member
02/18/2010
11DLS31006
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
SAFECO INS CO OF AM
6115146
02/18/2010
Until Cancelled
$12,000.00
03/28/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Alaska National
Ins Co
11DLS31006
04/01/2011
04/01/2012
$1,000,000.0003
/29/2011
2
ALASKA
NATIONAL
INSURANCE
COMP
10DLS31006
04/01/2010
04/01/2011
$1,000,000.0003
/31/2010
1
ALASKA
NATIONAL
INSURANCE
COMP
09DLS31006
02/18/2010
04/01/2010
$1,000,000.0003
/31/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
05/16/2011
FELE COPY
Permit No.. tilt-- %2*
Pier review approval Is subject to errors and omissions.
t; ;1,roval of construction documents does not authorize
t 1: v ;olatiof at any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
c)
WI
OVERALL SITE PLAN
Scale: 1"=60' 0"
PLASTICS
S
BUI
GALE
15,
LD1NG 781
BUSINESS PA
,580 S.F.
)OTPRINT
Rk
PROFESSIONAL PLASTICS.
NEW DRIVE IN DOOR
RAMP.
SEE ENLARGED PLAN
20 /TAI .0
FOR ALL WORK.
C
GC
C
By
Date:
City Of kwlla
BUILDING DIVISION
' T PERMIT
REQUIRED FOR:
LJ rAc chanical
Inectrical
DrPlumbing
2IeGas Piping
City of Tukwila
BUiL DING DIVISION
CODE COMPLIANCE
APPROVED
MAY 12 2011
A-7 City of Tukwila
BUILDING I1IVISIoN
REVISIONS
No chhanges shall be made to the scope
of work without prior approval of
Tukwila Building Division.
revisions will require a new plan submittal
cnd may include additional plan review fees.
PROJECT TEAM
PROPERTY
APPLICANT:
PROJECT DATA - PROFESSIONAL PLASTICS
ADDRESS
6233 SEGALE PARK DRIVE D, TUKWILA WA 98188
GENERAL
CONTRACTOR:
SEGALE PROPERTIES
5811 SEGALE PARK DRIVE C
TUKWILA, WA 98188
(206) 575 -2000
FAX (206) 575 -1837
CONTACT: BARRY BENNETT
EMAIL: BBENNETT @SEGALEPROPERTIES.COM
SEGALE PROPERTIES
P.O. BOX 88028
TUKWILA, WA 98188
(206) 575 -2000
CODE
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
2009 I.R.C., I.F.C., I.M.C., I.P.C.
B, S -1
V- B
Trila
G DOCK DOOR
TENANT PREMISE AREA:
EXISTING FIRST FLOOR OFFICE AREA
NEW OFFICE AREA
EXISTING WAREHOUSE
ARCHITECT:
PROFESSIONAL PLASTICS - DRIVE IN RAMP
0
000
sz co
Q
a
W <
—'
.�
V Q
W J
Cn --
N
3,333 S.F.
621 S.F.
24,705 S.F.
TOTAL TENANT AREA 28,659 S.F.
LANCE MUELLER Sc ASSOCIATES, SUITE 250
130 LAKESIDE AVE
SEATTLE, WA 98122
(206) 325 -2553
FAX (206) 328 -0554
CONTACT: HAROLD CHRISTENSEN
EMAIL: HAROLDC @LMUELLER.COM
THERMAL PERFORMANCE:
SEE ATTACHED ENERGY CALCULATIONS
E tS1 NG DOCK DOOR
EXISTING BUILDING DATA
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
ZONING:
BUILDING AREA:
BUILDING 781 (EXISTING)
TOTAL
ALLOWABLE AREA CALC:
V -N FIRE SPRINKLED
B -2. S
TVS
154,580 S.F.
UNLIMITED AREA PER I.B.C. SECTION 507.2 (BUILDINGS SPRINKLED
AND SURROUNDED ENTIRELY BY 60' PUBLIC WAYS OR YARDS)
LEGAL DESCRIPTION
VICINITY MAP
LOT 1 (ALSO DESCRIBED AND DELINEATED AS PARCEL A), CITY OF TUKWILA SHORT PLAT NO.
85- 19 -SS, RECORDED UNDER KING COUNTY RECORDING NO, 8505090619, BEING A PORTION OF
THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER AND THE SOUTHWEST QUARTER OF THE
NORTHEAST QUARTER AND GOVERNMENT LOTS 5 AND 6, ALL IN SECTION 35, TOWNSHIP 23 NORTH,
RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON.
TAX PARCEL NUMBER: 3523049112
PROJECT DECSRIPTION
SLOPE TO GRADE
4' -2
SLOPE
NEW ASPHALT RAMP TO DRIVE IN
DOOR WITH 42" HIGH CONCRETE
WALLS AT PERIMETER.
SEE STRUCTURAL DRAWINGS.
CREATE NEW DRIVE IN DOOR RAMP AT EXISTING DOCK HIGH DOOR. WORK WILL INCLUDE NEW
CAST IN PLACE CONCRETE WALLS 42" HIGH (FROM RAMP GRADE) AT SIDES OF RAMP AND
LANDING AT EXISTING MAN DOOR. RAMP SURFACE WILL BE ASPHALT PAVING.
INDEX OF DRAWINGS
ARCHITECTURAL
TA1.0
STRUCTURAL
S1
SITE PLAN / COVER SHEET
RAMP PLAN AND SECTION
EXISTING DOCK DOOR
EXISTING MAN DOOR
R
N
I
(206) 325 -2553
N
N
w
rn
W
W
•
REMOVE EXISTING PREFABRICATED
STAIR AT MAN DOOR. PROVIDE NEW
42" HIGH CONCRETE WALLS AROUND 4' -2 1/2”-
ASPHALT DOOR LANDING. SEE
STRUCTURAL DRAWINGS.
LJ_J_J_ LJ J_ J
10' -3 3/4"
RECEIVED
MAY 04 2C
PERMIT CENTER
ENLARGED SITE PLAN AT NEW RAMP
Scale: 1 /8 " =1 '-0"
(1)
sheet
I
w
0
O En
Id
J
0
Q C7
TA1.0
un
N
d-
a>
0
lo
PERMIT APPLICATION SET
O
(1,
d>
0
c
11076
job no.
HC
drawn
checked
4 -25 -11
date
REVISIONS
No chhanges shall be made to the scope
of work without prior approval of
Tukwila Building Division.
revisions will require a new plan submittal
cnd may include additional plan review fees.
PROJECT TEAM
PROPERTY
APPLICANT:
PROJECT DATA - PROFESSIONAL PLASTICS
ADDRESS
6233 SEGALE PARK DRIVE D, TUKWILA WA 98188
GENERAL
CONTRACTOR:
SEGALE PROPERTIES
5811 SEGALE PARK DRIVE C
TUKWILA, WA 98188
(206) 575 -2000
FAX (206) 575 -1837
CONTACT: BARRY BENNETT
EMAIL: BBENNETT @SEGALEPROPERTIES.COM
SEGALE PROPERTIES
P.O. BOX 88028
TUKWILA, WA 98188
(206) 575 -2000
CODE
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
2009 I.R.C., I.F.C., I.M.C., I.P.C.
B, S -1
V- B
Trila
G DOCK DOOR
TENANT PREMISE AREA:
EXISTING FIRST FLOOR OFFICE AREA
NEW OFFICE AREA
EXISTING WAREHOUSE
ARCHITECT:
PROFESSIONAL PLASTICS - DRIVE IN RAMP
0
000
sz co
Q
a
W <
—'
.�
V Q
W J
Cn --
N
3,333 S.F.
621 S.F.
24,705 S.F.
TOTAL TENANT AREA 28,659 S.F.
LANCE MUELLER Sc ASSOCIATES, SUITE 250
130 LAKESIDE AVE
SEATTLE, WA 98122
(206) 325 -2553
FAX (206) 328 -0554
CONTACT: HAROLD CHRISTENSEN
EMAIL: HAROLDC @LMUELLER.COM
THERMAL PERFORMANCE:
SEE ATTACHED ENERGY CALCULATIONS
E tS1 NG DOCK DOOR
EXISTING BUILDING DATA
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
ZONING:
BUILDING AREA:
BUILDING 781 (EXISTING)
TOTAL
ALLOWABLE AREA CALC:
V -N FIRE SPRINKLED
B -2. S
TVS
154,580 S.F.
UNLIMITED AREA PER I.B.C. SECTION 507.2 (BUILDINGS SPRINKLED
AND SURROUNDED ENTIRELY BY 60' PUBLIC WAYS OR YARDS)
LEGAL DESCRIPTION
VICINITY MAP
LOT 1 (ALSO DESCRIBED AND DELINEATED AS PARCEL A), CITY OF TUKWILA SHORT PLAT NO.
85- 19 -SS, RECORDED UNDER KING COUNTY RECORDING NO, 8505090619, BEING A PORTION OF
THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER AND THE SOUTHWEST QUARTER OF THE
NORTHEAST QUARTER AND GOVERNMENT LOTS 5 AND 6, ALL IN SECTION 35, TOWNSHIP 23 NORTH,
RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON.
TAX PARCEL NUMBER: 3523049112
PROJECT DECSRIPTION
SLOPE TO GRADE
4' -2
SLOPE
NEW ASPHALT RAMP TO DRIVE IN
DOOR WITH 42" HIGH CONCRETE
WALLS AT PERIMETER.
SEE STRUCTURAL DRAWINGS.
CREATE NEW DRIVE IN DOOR RAMP AT EXISTING DOCK HIGH DOOR. WORK WILL INCLUDE NEW
CAST IN PLACE CONCRETE WALLS 42" HIGH (FROM RAMP GRADE) AT SIDES OF RAMP AND
LANDING AT EXISTING MAN DOOR. RAMP SURFACE WILL BE ASPHALT PAVING.
INDEX OF DRAWINGS
ARCHITECTURAL
TA1.0
STRUCTURAL
S1
SITE PLAN / COVER SHEET
RAMP PLAN AND SECTION
EXISTING DOCK DOOR
EXISTING MAN DOOR
R
N
I
(206) 325 -2553
N
N
w
rn
W
W
•
REMOVE EXISTING PREFABRICATED
STAIR AT MAN DOOR. PROVIDE NEW
42" HIGH CONCRETE WALLS AROUND 4' -2 1/2”-
ASPHALT DOOR LANDING. SEE
STRUCTURAL DRAWINGS.
LJ_J_J_ LJ J_ J
10' -3 3/4"
RECEIVED
MAY 04 2C
PERMIT CENTER
ENLARGED SITE PLAN AT NEW RAMP
Scale: 1 /8 " =1 '-0"
(1)
sheet
I
w
0
O En
Id
J
0
Q C7
TA1.0
EXIST. STAIRS
TO BE REMOVED
A -1
TYP.
4' -8W"
w
0.
0
V)
in
4' —O" 0
SIDE
ACCESS
4' -6" TYP.
J
0 RAMP
' —O"
TYP.
NEW 6" C.I.P.
SLAB, TYP.
NEW 8" C.I.P.
SLAB, TYP.
RAMP PLAN
= 1' -0"
a
N3
0" TO 4' -0"
0
EQ
1 — #4 CONT. 0 T.O.W.
1 — #4 CONT. 0 HOOKED DOWEL
#4 2 ® 16" O.C. HORIZ.
6" CONC. DOCK RAMP w/
#4 0 16" O.C. E.W. MID —DEPTH
(VARIES)
1
EQ.
a
8" C.I.P. DOCK WALL w/
#5 0 15" O.C. VERT. &
#4 0 12" O.C. HORIZ.
2 "0 WEEP HOLES 0
4' -0" O.C. MAX.
1 — #4 CONT. 0 B.O.W.
11 "x31" CONT. WALL KEY
CRUSHED ROCK BACKFILL, TYP.
#4 0 18" O.C. TRANSVERSE TOP
Q�.'
—r-
iii— i
-1I lii —�! —�i —iii
- II ICI I ITI I I. I
HOLD 3"
CLR.
I l lTrI I 1=1 I I,iI l-
#4 0 18" O.C.
TRANSVERSE BOT.
PER PLAN
SECTION A -1
"
11-0"
N
9
0
0
4 — #5 LONG
TYP. TOP & BOT.
b 1 l'%-•
j REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 122011
City of Tukwila
BUILDING DIUIsICN
2 l�
RECEIVED
MAY 04 2011
P TCENTER
e�
v
O
Q
0
i
c
o
'6
'>
6
78094006
job no.
• c
J-0
J.K.
checked
4 -25 -11
date