Loading...
HomeMy WebLinkAboutPermit D11-126 - PROFESSIONAL PLASTICS - RAMPPROFESSIONAL PLASTICS 6233 SEGALE PARK DR D Dl 1 -126 City Aukwila � S Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 1 DEVELOPMENT PERMIT Parcel No.: 3523049112 Address: 6233 SEGALE PARK DR D TUKW Suite No: Project Name: PROFESSIONAL PLASTICS Permit Number: D11 -126 Issue Date: 05/16/2011 Permit Expires On: 11/12/2011 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: BARRY BENNETT Address: PO BOX 88028 , TUKWILA WA 98188 Contractor: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contractor License No: SEGALPL902CO Phone: 206 - 396 -2012 Phone: 206 - 575 -2000 Expiration Date: 04/01/2012 DESCRIPTION OF WORK: CONSTRUCT CONCRETE DRIVE IN RAMP. Value of Construction: $15,000.00 Fees Collected: $622.10 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: III -B Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11 -126 Printed: 05 -16 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: t ItO 1 I hereby certify that I have read and ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. ,.: 2 Signature: . -- Date: 6' // Print Name: `T NNL— - This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-126 Printed: 05 -16 -2011 this requirement. • • 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors m the construction documents and other data. doc: IBC -7/10 D11 -126 Printed: 05 -16 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** (Sk'DE LOCA'IPI Site Address: 6233 Segale Park Drive D Tenant Name: Professional Plastics Property Owners Name: Segale Properties LLC Mailing Address: PO Box 88028 King Co Assessor's Tax No.: 352304 -9112 Suite Number: N/A Floor: Ground New Tenant: m Yes ❑ ..No Tukwila City WA State 98138 Zip TAC PERS o we,contaei 'our permit Isgready otbe &z.ssue Name: Barry Bennett Mailing Address: PO Box 88028 E -Mail Address: Bbennett@segaleproperties.com Day Telephone: Tukwila (206) 396 -2012 WA City State Fax Number: (206) 575 -1662 98138 Zip ENERALCONTRACT ontractor ;l of ormation for RINFURMATION. ech ical (pg4),forWP Company Name: Segale Properties LLC Mailing Address: PO Box 88028 Contact Person: Barry Bennett E -Mail Address: Bbennett @segaleproperties.com Contractor Registration Number: SEGALPL902CQ Tukwila WA City State Day Telephone: (206) 396 -2012 Fax Number: (206) 575 -1662 98138 Zip Expiration Date: 04/01/2012 A` RCHITECT 3 OF RECORD Alltplansrmust\be stamped yy iitecfof.7 Company Name: Lance Mueller and Associates Mailing Address: 130 Lakeside Suite 250 Contact Person: Harold Christensen E -Mail Address: HaroldC @Imueller.com Seattle City WA State Day Telephone: (206) 325 -2553 Fax Number: (206) 328 -0554 98122 Zip ENGINERS OF BT;CORD'� ans muyst�ybestamp 3 u neer, ofi Company Name: Engineers Northwest Mailing Address: 6869 Woodlawn Avenue NE Contact Person: Dale Kaemingk E -Mail Address: DaleK @engineersnw.com H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Applicetion.doc Revised: 7 -2010 bh Seattle WA City State Day Telephone: (206) 525 -7560 Fax Number: (206) 522 -6698 98115 Zip Page 1 of 6 DING RMATIC Valuation of Project (contractor's bid price): $ 15,000.00 Existing Building Valuation: $ Scope of Work (please provide detailed information): Construct concrete drive in ramp. Will there be new rack storage? ❑ Yes O.. No If yes, a separate permit and plan submittal will be required. 'Iti$1ui1d easdneS ommy luareil oe struction:per 154,580 0 640 3N S -2, B k2 ".° FIaoi' Floors "' Basemen ccessoi Structur333333333*77f3f3f3f3n i3j 33 3 3i 3i3k3i773i'3 Attached'Garag ad;Garaj *Attached, IDetacuuur3n Carpia -Namur A33N3r3,�., Covered Deck''' ,Uncovered= PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 46 Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fomu- Applications On Line\2010 Applications \7-2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 ITAPDICAITION NOT • thcableto a • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: B Mailing Address: Bennett PO Box 88028 IDate Application Accepted: Day Telephone: Tukwila City Date: 5 -2 -11 206 - 396 -2012 WA State 98188 Zip Date Application Expires: Staff Initials: H: Wpplications\Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 . . wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT ParcelNo.: 3523049112 Permit Number: D11 -126 Address: 6233 SEGALE PARK DR D TUKW Status: PENDING Suite No: Applied Date: 05/04/2011 Applicant: PROFESSIONAL PLASTICS Issue Date: Receipt No.: R11 -00891 Payment Amount: $622.10 Initials: BLH Payment Date: 05/04/2011 01:04 PM User ID: ADMIN Balance: $0.00 Payee: SEGALE PROPERTIES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 629842 622.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $622.10 374.30 243.30 4.50 doc: Receipt -06 Printed: 05 -04 -2011 " " ' • . . INSPECTION:RECORtil Retain a copy with permit tiCI-12-Cdo IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: P■10Cr-es$IONIA L. Type of Inspection: (---.1KIAL- (`‘,,i,./..,_v t es.4 e i Address: (-/,? a .sF cp.v. PAR' Date Called: n Special Instructions: Date Wanted: 7-5-11 aicr: Requester: Phone No: aD( 0-31,.. -Ogg 1J Approved per applicable codes. El Corrections required prior to approval. COMMENTS: (`‘,,i,./..,_v t es.4 e i . , /..) A ( . . . . t Date: - \- - NSPECTION FEE REQUI D. Prior to r13t inspection. fee niustp.e. • .,. . • d at 6300 Southcenter Blvd.. Suite 100. Call to schedule ieinspetfilin.. •'. • .. , • • -...? • • _ • : "��: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro'ect: -PI sKi 1 a c e - 5 5 ■ o a > , r ► + . I n c Type of Inspection: -- b&T t t^3 4s - Address: (0A-3 44(00+4_ Petal) Date Called: Special Instructions: Date Wanted: (� -1— t\ a.m` m. Requester: Phone No: 0062 -- b1L.-1 ?Piy proved per applicable codes. Corrections required prior to approval COMMENTS: i s pec , r: REI pai • • . 1 - 1 a SPECTION FEE REQ ED. Prior to text inspection. fee must be' . ' .' at 6300 Southcenter Blvd.. Suite 100, all to schedule reinspectiori: • • PE T PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: 011 -126 DATE: 05 -04 -11 PROJECT NAME: PROFESSIONAL PLASTICS SITE ADDRESS: 6233 SEGALE PARK DR D X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 5-441-l\ Lidding vision tanning Division g �_ ), Sr Ire Prevention ,.i, Pu tic Works r� Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-05-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 06-02-11 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 i I III F625- 052 -000 (8/97) DEPARTMENT OF LABOR Al! rp:.D REGISTERED AS PROVIDED BY LAW A CONST CONTR GENERAL REGIST. # EXP. DATE CCOI SEGALPL902CQ 4/1/2012 EFFECTIVE DATE 2/18/2010 SEGALE PROPERITIES LLC PO BOX 88028 TUKWILA WA 98138 -2028 Contractors or Tradespeople Per Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SEGALE PROPERITIES LLC UBI No. 602023533 Phone 2065752000 Status Active Address Po Box 88028 License No. SEGALPL902CQ Suite /Apt. License Type Construction Contractor City Tukwila Effective Date 2/18/2010 State WA Expiration Date 4/1/2012 Zip 981382028 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LAPIALP055MZ LA PIANTA LIMITED PARTNERSHIP Construction Contractor General Unused 7/9/1995 4/1/2001 Archived SEGALBP151M5 SEGALE BUSINESS PARK Construction Contractor General Unused 7/25/1985 7/9/1995 Archived LAPIAL•008J8 LA PIANTA LLC Construction Contractor General Unused 4/28/2000 4/1/2010 Inactive Business Owner Information Name Role Effective Date Expiration Date SEGALE, MARIO A Agent 02/18/2010 Amount SEGALE, MARIO A Partner /Member 02/18/2010 11DLS31006 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 SAFECO INS CO OF AM 6115146 02/18/2010 Until Cancelled $12,000.00 03/28/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Alaska National Ins Co 11DLS31006 04/01/2011 04/01/2012 $1,000,000.0003 /29/2011 2 ALASKA NATIONAL INSURANCE COMP 10DLS31006 04/01/2010 04/01/2011 $1,000,000.0003 /31/2010 1 ALASKA NATIONAL INSURANCE COMP 09DLS31006 02/18/2010 04/01/2010 $1,000,000.0003 /31/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 05/16/2011 FELE COPY Permit No.. tilt-- %2* Pier review approval Is subject to errors and omissions. t; ;1,roval of construction documents does not authorize t 1: v ;olatiof at any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: c) WI OVERALL SITE PLAN Scale: 1"=60' 0" PLASTICS S BUI GALE 15, LD1NG 781 BUSINESS PA ,580 S.F. )OTPRINT Rk PROFESSIONAL PLASTICS. NEW DRIVE IN DOOR RAMP. SEE ENLARGED PLAN 20 /TAI .0 FOR ALL WORK. C GC C By Date: City Of kwlla BUILDING DIVISION ' T PERMIT REQUIRED FOR: LJ rAc chanical Inectrical DrPlumbing 2IeGas Piping City of Tukwila BUiL DING DIVISION CODE COMPLIANCE APPROVED MAY 12 2011 A-7 City of Tukwila BUILDING I1IVISIoN REVISIONS No chhanges shall be made to the scope of work without prior approval of Tukwila Building Division. revisions will require a new plan submittal cnd may include additional plan review fees. PROJECT TEAM PROPERTY APPLICANT: PROJECT DATA - PROFESSIONAL PLASTICS ADDRESS 6233 SEGALE PARK DRIVE D, TUKWILA WA 98188 GENERAL CONTRACTOR: SEGALE PROPERTIES 5811 SEGALE PARK DRIVE C TUKWILA, WA 98188 (206) 575 -2000 FAX (206) 575 -1837 CONTACT: BARRY BENNETT EMAIL: BBENNETT @SEGALEPROPERTIES.COM SEGALE PROPERTIES P.O. BOX 88028 TUKWILA, WA 98188 (206) 575 -2000 CODE OCCUPANCY GROUP: CONSTRUCTION TYPE: 2009 I.R.C., I.F.C., I.M.C., I.P.C. B, S -1 V- B Trila G DOCK DOOR TENANT PREMISE AREA: EXISTING FIRST FLOOR OFFICE AREA NEW OFFICE AREA EXISTING WAREHOUSE ARCHITECT: PROFESSIONAL PLASTICS - DRIVE IN RAMP 0 000 sz co Q a W < —' .� V Q W J Cn -- N 3,333 S.F. 621 S.F. 24,705 S.F. TOTAL TENANT AREA 28,659 S.F. LANCE MUELLER Sc ASSOCIATES, SUITE 250 130 LAKESIDE AVE SEATTLE, WA 98122 (206) 325 -2553 FAX (206) 328 -0554 CONTACT: HAROLD CHRISTENSEN EMAIL: HAROLDC @LMUELLER.COM THERMAL PERFORMANCE: SEE ATTACHED ENERGY CALCULATIONS E tS1 NG DOCK DOOR EXISTING BUILDING DATA CONSTRUCTION TYPE: OCCUPANCY TYPE: ZONING: BUILDING AREA: BUILDING 781 (EXISTING) TOTAL ALLOWABLE AREA CALC: V -N FIRE SPRINKLED B -2. S TVS 154,580 S.F. UNLIMITED AREA PER I.B.C. SECTION 507.2 (BUILDINGS SPRINKLED AND SURROUNDED ENTIRELY BY 60' PUBLIC WAYS OR YARDS) LEGAL DESCRIPTION VICINITY MAP LOT 1 (ALSO DESCRIBED AND DELINEATED AS PARCEL A), CITY OF TUKWILA SHORT PLAT NO. 85- 19 -SS, RECORDED UNDER KING COUNTY RECORDING NO, 8505090619, BEING A PORTION OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER AND THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER AND GOVERNMENT LOTS 5 AND 6, ALL IN SECTION 35, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON. TAX PARCEL NUMBER: 3523049112 PROJECT DECSRIPTION SLOPE TO GRADE 4' -2 SLOPE NEW ASPHALT RAMP TO DRIVE IN DOOR WITH 42" HIGH CONCRETE WALLS AT PERIMETER. SEE STRUCTURAL DRAWINGS. CREATE NEW DRIVE IN DOOR RAMP AT EXISTING DOCK HIGH DOOR. WORK WILL INCLUDE NEW CAST IN PLACE CONCRETE WALLS 42" HIGH (FROM RAMP GRADE) AT SIDES OF RAMP AND LANDING AT EXISTING MAN DOOR. RAMP SURFACE WILL BE ASPHALT PAVING. INDEX OF DRAWINGS ARCHITECTURAL TA1.0 STRUCTURAL S1 SITE PLAN / COVER SHEET RAMP PLAN AND SECTION EXISTING DOCK DOOR EXISTING MAN DOOR R N I (206) 325 -2553 N N w rn W W • REMOVE EXISTING PREFABRICATED STAIR AT MAN DOOR. PROVIDE NEW 42" HIGH CONCRETE WALLS AROUND 4' -2 1/2”- ASPHALT DOOR LANDING. SEE STRUCTURAL DRAWINGS. LJ_J_J_ LJ J_ J 10' -3 3/4" RECEIVED MAY 04 2C PERMIT CENTER ENLARGED SITE PLAN AT NEW RAMP Scale: 1 /8 " =1 '-0" (1) sheet I w 0 O En Id J 0 Q C7 TA1.0 un N d- a> 0 lo PERMIT APPLICATION SET O (1, d> 0 c 11076 job no. HC drawn checked 4 -25 -11 date REVISIONS No chhanges shall be made to the scope of work without prior approval of Tukwila Building Division. revisions will require a new plan submittal cnd may include additional plan review fees. PROJECT TEAM PROPERTY APPLICANT: PROJECT DATA - PROFESSIONAL PLASTICS ADDRESS 6233 SEGALE PARK DRIVE D, TUKWILA WA 98188 GENERAL CONTRACTOR: SEGALE PROPERTIES 5811 SEGALE PARK DRIVE C TUKWILA, WA 98188 (206) 575 -2000 FAX (206) 575 -1837 CONTACT: BARRY BENNETT EMAIL: BBENNETT @SEGALEPROPERTIES.COM SEGALE PROPERTIES P.O. BOX 88028 TUKWILA, WA 98188 (206) 575 -2000 CODE OCCUPANCY GROUP: CONSTRUCTION TYPE: 2009 I.R.C., I.F.C., I.M.C., I.P.C. B, S -1 V- B Trila G DOCK DOOR TENANT PREMISE AREA: EXISTING FIRST FLOOR OFFICE AREA NEW OFFICE AREA EXISTING WAREHOUSE ARCHITECT: PROFESSIONAL PLASTICS - DRIVE IN RAMP 0 000 sz co Q a W < —' .� V Q W J Cn -- N 3,333 S.F. 621 S.F. 24,705 S.F. TOTAL TENANT AREA 28,659 S.F. LANCE MUELLER Sc ASSOCIATES, SUITE 250 130 LAKESIDE AVE SEATTLE, WA 98122 (206) 325 -2553 FAX (206) 328 -0554 CONTACT: HAROLD CHRISTENSEN EMAIL: HAROLDC @LMUELLER.COM THERMAL PERFORMANCE: SEE ATTACHED ENERGY CALCULATIONS E tS1 NG DOCK DOOR EXISTING BUILDING DATA CONSTRUCTION TYPE: OCCUPANCY TYPE: ZONING: BUILDING AREA: BUILDING 781 (EXISTING) TOTAL ALLOWABLE AREA CALC: V -N FIRE SPRINKLED B -2. S TVS 154,580 S.F. UNLIMITED AREA PER I.B.C. SECTION 507.2 (BUILDINGS SPRINKLED AND SURROUNDED ENTIRELY BY 60' PUBLIC WAYS OR YARDS) LEGAL DESCRIPTION VICINITY MAP LOT 1 (ALSO DESCRIBED AND DELINEATED AS PARCEL A), CITY OF TUKWILA SHORT PLAT NO. 85- 19 -SS, RECORDED UNDER KING COUNTY RECORDING NO, 8505090619, BEING A PORTION OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER AND THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER AND GOVERNMENT LOTS 5 AND 6, ALL IN SECTION 35, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON. TAX PARCEL NUMBER: 3523049112 PROJECT DECSRIPTION SLOPE TO GRADE 4' -2 SLOPE NEW ASPHALT RAMP TO DRIVE IN DOOR WITH 42" HIGH CONCRETE WALLS AT PERIMETER. SEE STRUCTURAL DRAWINGS. CREATE NEW DRIVE IN DOOR RAMP AT EXISTING DOCK HIGH DOOR. WORK WILL INCLUDE NEW CAST IN PLACE CONCRETE WALLS 42" HIGH (FROM RAMP GRADE) AT SIDES OF RAMP AND LANDING AT EXISTING MAN DOOR. RAMP SURFACE WILL BE ASPHALT PAVING. INDEX OF DRAWINGS ARCHITECTURAL TA1.0 STRUCTURAL S1 SITE PLAN / COVER SHEET RAMP PLAN AND SECTION EXISTING DOCK DOOR EXISTING MAN DOOR R N I (206) 325 -2553 N N w rn W W • REMOVE EXISTING PREFABRICATED STAIR AT MAN DOOR. PROVIDE NEW 42" HIGH CONCRETE WALLS AROUND 4' -2 1/2”- ASPHALT DOOR LANDING. SEE STRUCTURAL DRAWINGS. LJ_J_J_ LJ J_ J 10' -3 3/4" RECEIVED MAY 04 2C PERMIT CENTER ENLARGED SITE PLAN AT NEW RAMP Scale: 1 /8 " =1 '-0" (1) sheet I w 0 O En Id J 0 Q C7 TA1.0 EXIST. STAIRS TO BE REMOVED A -1 TYP. 4' -8W" w 0. 0 V) in 4' —O" 0 SIDE ACCESS 4' -6" TYP. J 0 RAMP ' —O" TYP. NEW 6" C.I.P. SLAB, TYP. NEW 8" C.I.P. SLAB, TYP. RAMP PLAN = 1' -0" a N3 0" TO 4' -0" 0 EQ 1 — #4 CONT. 0 T.O.W. 1 — #4 CONT. 0 HOOKED DOWEL #4 2 ® 16" O.C. HORIZ. 6" CONC. DOCK RAMP w/ #4 0 16" O.C. E.W. MID —DEPTH (VARIES) 1 EQ. a 8" C.I.P. DOCK WALL w/ #5 0 15" O.C. VERT. & #4 0 12" O.C. HORIZ. 2 "0 WEEP HOLES 0 4' -0" O.C. MAX. 1 — #4 CONT. 0 B.O.W. 11 "x31" CONT. WALL KEY CRUSHED ROCK BACKFILL, TYP. #4 0 18" O.C. TRANSVERSE TOP Q�.' —r- iii— i -1I lii —�! —�i —iii - II ICI I ITI I I. I HOLD 3" CLR. I l lTrI I 1=1 I I,iI l- #4 0 18" O.C. TRANSVERSE BOT. PER PLAN SECTION A -1 " 11-0" N 9 0 0 4 — #5 LONG TYP. TOP & BOT. b 1 l'%-• j REVIEWED FOR CODE COMPLIANCE APPROVED MAY 122011 City of Tukwila BUILDING DIUIsICN 2 l� RECEIVED MAY 04 2011 P TCENTER e� v O Q 0 i c o '6 '> 6 78094006 job no. • c J-0 J.K. checked 4 -25 -11 date