Permit D11-134 - WESTFIELD SOUTHCENTER MALL - DOWNEAST BASICS - REMODEL
DOWNEAST BASICS 1010 SOUTHCENTER MALL Dl 1 -134 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parce:. No.: 9202470010 Address: 1010 SOUTHCENTER MALL TUKW Suite No: Project Name: DOWNEAST BASICS Permit Number: D11 -134 Issue Date: 06/14/2011 Permit Expires On: 12/11/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: JUSTIN HODGES Address: 1187 S 1480 W , OREM UT 84058 Contractor: Name: RIMROCK CONSTRUCTION LLC Address: 11635 S 700 E, #100 , DRAPER UT 84020 Contractor License No: RIMROCL9107M Phone: 801 - 755 -9959 Phone: 801 - 676 -7625 Expiration Date: 10/13/2011 DESCRIPTION OF WORK: REMODEL, DRESSING ROOMS, NEW STOREFRONT. COMPLETE INTERIOR CHANGE Value of Construction: $150,000.00 Fees Collected: $3,113.76 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: II-B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11-134 Printed: 06 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: L)i2.L< `� Date: lY —1 L v I I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o erformance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this pe r Signatu Date: Print Name: J r/ 519 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11-134 Printed: 06 -14 -2011 7: All construction shall be done in conform. with the approved plans and the requirem of the International Building Code or International Residential C International Mechanical Code, Washingt to Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Buildiag Official from requiring the correction of errors in the construction documents and other data. 12: "*FIRE DEPARTMENT CONDI'T'IONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be doc: IBC -7/10 D11-134 Printed: 06 -14 -2011 less than 0.375 inch (9.5 mm). Signs larger t the minimum established in section 1011.5.1 ° the International Fire Code shall have letter widths, strokes and s g in proportion to their height. The word " " shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least art average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot - candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: Post address on storefront per approved Westfield standards. 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -134 Printed: 06 -14 -2011 • • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. ' Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 2 Co Z 30'-f — 403Z. Site Address: S O L > %Vi Ca.r l e r 5e i (e 4)4. 9 g f ge Suite Number: Floor: 1 Tenant Name: f, .',9 crg� Property Owners Name: t e-S¢G, G(d (.—fl Mailing:Address: f ((00( Cfv /1 `u fi New Tenant: Er Yes ❑ .. No L65 -Aq G /e 5 City / State la" 2,S" Zip CON'T f-PER ro do we contact wben your permit is ready4o bensued Name: JL SI.. H I r 9G S Mailing Address: !/ 3 7 s [ 4 $0 er E -Mail Address: cL i;? - A =t, CONTR`AC T ©R IN 'ORM �'CTL ontra torlaformation or,•;Mechanieai(pg_4).fo Plumbing:ani TOO ! Company Name: Mailing.Address: Day Telephone: 501 - 7 __- q :5"61 OtAetif (,!T SciosS City Fax Number: State Zip Contact Person: E -Mail Address: Contractor Registration Number: 4' City Day Telephone: Fax Number: Expiration Date: State Zip Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip SENGINEER O 42ECORD Atl.p al ns must }be stamped weer offRecor Ram Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications\Fomu- Applications On Line 12010 Applications\7 -2010 - Permit Application.doc Revised: 7-2010 bh Page 1 of 6 MID** G' P RMI 4'4" Valuation of Project (contractor's bid price): $ !, )/ 000 Scope of Work (please provide detailed information): �"`a ( (e. Existing Building Valuation: $ ,(7dGsy:y Will there be new rack storage? ❑ Yes eNo If yes, a separate permit and plan submittal will be required. e All B ding A er as m,SquareFootage PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: E7 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes V No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 1; ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health- Department. H: Applicntioas'Fonns- Applications On Line\2010 Applications\7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 , xistin g :��• 1 tenor Remodel h t Y Ads to� s`,ExiB.tinga Strad lure L'+� N.Fj / 5 a n New fi T i v�ke, Type of Constnictloi `' T. e o Occupanncy per Or *2" F1' or oor�:�r fr 'Floors "thru Basemen` <� u AccessorypStructure* Attached Garage • 1® etached Garage � n Ached ?Carports DetachedCarport ACovered Deck Uncovers Decker PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: E7 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes V No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 1; ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health- Department. H: Applicntioas'Fonns- Applications On Line\2010 Applications\7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 vtie 1 itiM4 ' A'PPLICAti iO k Tts Applicable o m his appheation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. •1Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be ,requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: /J Print Nate: E OR AUTHORIZED AGENT: 4'4e Pet.' Akaeliao< , Mailing.Address: // 53 7 5 I 30 Date: 5/3/II Day Telephone: Do( 753- .9q -c ur gted S'S� City State Zip IDate Apli ication Accepted: s^ 1/1_4 ' j Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line12010 Applications\7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11-134 Address: 1010 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/13/2011 Applicant: DOWNEAST BASICS Issue Date: Receipt No.: R11 -01197 Payment Amount: $1,888.90 Initials: WER Payment Date: 06/14/2011 11:52 AM User ID: 1655 Balance: $0.00 Payee: WILLIAM FREEDMAN (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01756D ACCOUNT ITEM LIST: Description 1,888.90 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $1,888.90 1,884.40 4.50 doc: Receiot -06 Printed: 06 -14 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11-134 Address: 1010 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/13/2011 Applicant: DOWNEAST BASICS Issue Date: Receipt No.: R11 -00974 Initials: User ID: Payee: WER 1655 Payment Amount: $1,224.86 Payment Date: 05/13/2011 02:19 PM Balance: $1,888.90 RICHARD ISRAELSEN (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 044666 ACCOUNT ITEM LIST: Description 1,224.86 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,224.86 Total: $1,224.86 doc: Receiot -06 Printed: 05 -13 -2011 INSPECTION N INSPECTION RECORD Retain a copy with permit 0'1 -134.1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 i” (2i# 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro t: (JJ^ C-J1- TYP )n cJt� Do . l Add 1 J S L 11-4 4 I Date Called: Special Instructions: Date Wanted: .11„ ,,a�. „If s Requester: Phone Q: t ' 6208.-5/ C;• 27 Approved per applicable codes. Corrections required prior to approval. COMMENTS: - - e 1 A(7- £ P\ / e IInsPectEI Dater IS ( 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD 3((-'34 Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 ' Per,mit'Inspection Request Line (206) 431 -2451 Project: • . L,:i x/21,4 ST— Type of nspection: F-: Al A L_-3 •' 10: n Address: I 0 t as S c._. di-c kid— Date Called: . Specialinstructions: • Date Wanted /� is a.m. Requester: Phone Nom t ! Q • _ '54 110 Approved per applicable codes. COMMENTS: Corrections required prior to approval. ��1�'tllt>1�t Inspector: I . Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. _31sw INSPECTION NO. INSPECTION RECORD Retain a copy with permit 011-1 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Prn t: Typrf,10 nspection: Address: I(.) ( L3 Sc AA t.-(-..- Date Called: i 'A DAV Special Instructions: • Date Wanted:. 5„.'S — (( p.m. Requester: g)1,1 V. . A GJ h: i'E,__. Phone ' _ 6 o - .5.4% Approved per applicable codes. Corrections required prior to approval. COMMENTS: n _ (I . RV( J J .d r ---7-6.-.) i 'A DAV ( tj-P eS g)1,1 V. . A GJ h: i'E,__. , j\- (...r._ P_c: L; P 5)1,..A1 @ 13,4-41- Ibail er eQ r (s.S , .—f, ( 11 M ( A Inspec o '4A 1) REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 6((- ;w•:: sP.KTLON 0.; *' PERMIT NO. vl c_i / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter,=B1vd.., #100, Tukwila. WA 98188 _ (206) 431 -3670 ' Permit Inspection.Request Line(206) 431 -2451 L ;: ` • Retain a copy with permit r • • • r i . tr Prod t• f ,, i AJ G-%� E Typ f Inspection: AL t t. (EQ i n q Address: ��. l .. r � t. —. '• CL )4 4-fl Date Called: SpeciatInstructions: • 3 ( g ' r of - Date Wanted: Requester: ‹l Phone No: k 0 t --- (� 60 c — 54 ( qio Approved per applicable codes. E Corrections required prior to approval. COMMENTS: - 4o Ays- ‹l . Cr9 611 T citkl, -�!\t _ , .c ` mi 417 t` O0 rt ( P . JAI a 4/c hi 1:"\-/ N,,,,4.;,,,, .# ` • I 1 REINSPECTION FEE REQUIRED. Prior \to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • Inspet-k ct INSPECTION RECORD Retain a copy with permit 0 1 U. 431 INSPECTION NO. PERMIT NO. CITY'OF TUKWILA BUILDING DIVISION' • • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 • Permit Inspection Request Line (206) 431 -2451 Project: btlAi I� E I ; aAs��� Type of Inspection: s C. Mere. L-� 6 ( -Cr(AL Address: 10 (O S M 4a.-- Date Called: Special Instructions: a . Date Wanted: ®.m 1- Zm — (t p.m. Requester: Phone No: 3 -255- t41 9r7 proved per applicable codes. El Corrections required prior to approval. COMMENTS: nspect Date: E SPECTION FEE R ' UIRED. Prig}f to next inspection, fee must be p- id at 6300 Southcenter Blvd.. Suitef100. Call to schedule reinspection. • •a INSPECTION NO. ECORD Retain a copy with permit 7// 64. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project a1 Type of Inspection: AddresC s mAtz. r Date Called: tl _. Special Instructions: (9/� /' / / r 4o ✓ 1 `� �.�to' "—" alF Date Wanted: a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: p A. a1 {vck AI/? 1�1tlt 51' r ca r i---0 4isi 0k kcir, _. FA'^vtd , t7 t trr Gc'l a Q .e, LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �, �.. ... ._mac. •.J v-'. 1. •i.i.j;. •- .tea ''l i =�:,;' INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro'ect: Dv n 3AstGs Type o nspction: s - G , L. A la Address: r0t0 SC MALL Date Called: !�' � Special Instructions: / Date Wanted: -7- / — If ,m l P - m- Requester: Phone No: se)( -Coo g -141 Approved per applicable codes. [J Corrections required prior to approval. COMMENTS: yy InspectoC J P for Date: n REINSPECTION FEE REQUIR ED. to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Nd•r4-.... • RietiRIV* (.■ r;•". INtPECTI Retain a copy with permit 01( /— INSPECTION NO. PERMIT Na CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Project: ......... e_ 5 &s' Type of Ingion.:.,,, Address: ) () ( 0 S<..— i Date Called: Speciar nstructions: 1 Date Wanted: a. m. ---) - 7,13— ( i \ it: Requester: Phone No: gO i — 608---.54qiel El Approved per applicable codes. Corrections required prior to approval. 6 COMMENTS: In pector: Datei--?... 24, r-7 REINSPECTION FEE REdrED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,k (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: } Address: 1 0 t 0 Sc )4 #'.- -- Date Called: Special Instructions: Date Wanted: —7 — / q — (�' - ..a.m) p.m. Requester: Phone 0. ! ry g 54 q10 LIApproved per applicable codes. Corrections required prior to approval. COMMENTS: .j t ) Pc4kAf f Ae-c A A • Cl f eT A1,21--- 5-A S ;re f o' `mil„`. s; Ls? e-J.' i A (7D Corc,›- 6--t e..: 7: c tom., I-2 Ai C k f s' e l i r~- b 1� Inspect or: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD.: Retain a copy with permit 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 '• fr.- (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: IbOCOK)F�sr e p G. Type of Inspection --T- Address: •' 1010 M ALL_ Date Called: Special Instructions: Date Wanted: Requester: Phone No: g0 - (008 .- -52 6 'Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Date: • • ECTION REQ ED . Prio to next inspection. fee trust ',be 6300 Southcenter Blvii.. Suite 100. Call to schedule reinspecticn.• . • • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1,•,, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 -4* Pro'ect: ....------„ . /LC i) s 65 Type of Inspection ?, K,:,' A.) 15 dress: 1 il 1 0 SC-- tAAA-I-L- Date Called: Special Instructions: Date Wanted:Wanted:...., a.m .—......• P.m. Requester: • Phone No: Approved per applicable codes. ,• ,. . - 1:1Corrections required prior to approval. •-.01, COMMENTS: ft-1 AN/ 1 u J A-C--- rkr—r-- in A c`r O1/41e-r ir■ ea.4 eD ,c.--b)e-e., 4-#A7, pf .. :. .... • . : • . 1 Inspect r: Date: . . • • REINSPECTION FEE REQUIRED. Prior to next inspeCtion, fee mutt:be,.`. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection't:;, • • • - -• • • INSPECTION RECORD Retain a copy with permit . • • PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 __ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: s"r- (3As-, ( 5 Type of Inspection: 61- I M A (, Address: In 10 Date Called: Special Instructions: ..-- Date Wanted: a.m. (0-3° - i tKIC19 Requester: Phone No: 0 ( — 6 OW —52i-lco Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect CL4 jUk-i • ; N1" paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule r-einspeclion; . • . Date: t INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit - 5 i' • - 0°1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa: 98188 206 - 575 -4407 Project: �aw� E.R Sprinklers: Ycs- . Type of Inspection: FA, > R\(AC. , SQk ,,,..L, r Address: 1 b1 t 5,c, Suite #: v\,\\ Contact Person: Special Instructions: Pre -Fire: TA 'Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ;l4L. , Pf-A / � �. � \��CS , 9-44k< c51C • Needs Shift Inspection:.' CS Sprinklers: Ycs- . Fire Alarm: VA E; c kioY, s- Hood & Duct: Monitor: C-, Pre -Fire: TA Permits: , Occupancy Type: ' Y\ Inspector:�`r\�1 Date: S\ 411 Hrs.: , n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 4- Company Nanae: Address: City: Word /Inspection Record Form.Doc Stdte: 1 Zip: 4 T.F.D. Form F.P. 113 •: . • • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit X31.1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 • Project: Doc,„h �a 74— 04 5 ,. 5 Type -of Inspection: Spi,.eil J c . C0 r+.. Address: / 010 Suite # :. S G rvi .± Contact Person: 4 Special Instructions: Phone No.: VzS- e/ - 7LGSr Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0/4 -� Ca✓r z r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fir: - Permits: Occupancy Type: Inspector:. ,G�J $ 3 Date: 7// 7A/ Hrs.: ; / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 • •,, INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 1 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Proj ct: r of i & 's4 Sprinklers: Hrs.: i Cs Type of Inspection: Zr �v�f' Address: /b iO Suite #: C h -'� -t__- Contact Person: Special Instructions: • Phone No.: GL—Approved per applicable codes. Corrections required prior to approval. COMMENTS: o(c _ 77, C'av -e.r" Needs Shift Inspection: Sprinklers: Hrs.: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • Inspector: "-\ c y, 5-r.}-- Date: 6ta7 / t I Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 'Billing Address Attn: Company, Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 11 -5- /& .tit- 1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98.188 206 -575 -4407 Project: 1 nJ C.,-WS CV-144)(S Type of Inspection: S e Caugr- Address: �0 �0 Suite #: C • /+4,4- L� Contact Person: `Special Instructions: Occupancy Type: Phone No.: I I Approved per applicable codes. A€ orrections required prior to approval. COMMENTS: Sprinklers: 1, &aL WI s; ek (tee 7/ s ) Hood & Duct: 0, /kIt.,Qr ( sec P /ANS) Pre -Fire: x pZ Occupancy Type: 3. gemove liti s4 c_ 544-0410 (sue p /�rluS . cPO ) • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: % a_ Date: G/ 23/0 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 Jun 04• 11 02:58p Ameriwest Electric 2009 Washington State Energ 1-801- 255 -3992 Code Compliance Form for Nonresidential and Multifami Residential LTG -INT p.5 Interior Lighting Summary 2009 Washington State Energy Coda Compliance Forms for Nonresidential and Multifamily Residential Project Address Do E0.s c".5i �5 1010 Se> - L(2A-+er ANI Project Info Applicant Name: SkS4-. ) ._ J Date Revised November 2010 For Building Department Use Applicant Address: 118, -7 c 14 L7 i { 1Y'! . kA-r g ^r'" Applicant Phone: FILE COPY RJ► fkti,� Project Description ❑ New Building ❑ Addition U Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option IQ Prescriptive ca Lighting Power Allowance Q Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ❑ Less than 6096 of the fixtures new, installed wattage not increased. & space use not changed. Maximum Allowed Lighting Wattage Location (floor planlroom #) E 2;. Occupancy Description Allowed Watts perftz "' Gross irdenor Area in ft2 1 1 0 Allowed x Area -; " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts rroposea ,l agnnng rvdtragr Location (floor r pl anhoom 1Y) Fixture Description Number of Fixtures Watts; Fixture Watts Proposeci -' L r i y,a iy to e% ft./4, o �i 4 le. - = z �a z T,- -�f:.- ! H'i Z 0 6, : /2-,10 2 , D � moo.. �,, ��� a�`�a a Tu-J^e S.v:o �vos- user. -+ �% ire/ 256 E 2• ei eArT1- c1 ge e -r gel CG..., 7 "i..i / 5 /N w ceL 2-10 c z. 4 2 -0 dQFcirtre -c Sc,eKc.e / Z.0) tJ 2tJC: — AMU- - r_� a........va .sleffin mum/ r.nt Rneaed Tonal Allowed Watts for interior Total Proposed Watts .•S 2_2_ Notes: 1. For proposed Fixture Descrtpllon, indicate fixture type. Tamp type (e.g. T$), number of lamps In the fixture, and ballast type (if included). For track lighting, list the length of the track ('m feet) in addition to the fixture. tamp, and ballast information. 2. For proposed WattslFudure. use manufacturer's fisted maximum input wattage of the fodure (not simply the Tamp wattage) and other criteria as specified in Section 1530. For fate voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable. the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave WattslFlxture blank. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 10 2011 City of TukWII BUILDING DIVISION CORRECTION cmru► JUN O 1 2011 '('� I PERRIIITC�Ni�R ; � Jun '01 11 02:57p Ameriwest Electric 2009 Washington State Energ 1-801- 255 -3992 Code Compliance Form for Nonresidential and Multifami Residential LTG -iNT p.4 Interior Lighting Summary 2009 Washington State Energy Code Compliance Rams for Nonresidential and Muttfsrniy Residential Prescriptive Spaces Occupancy. 0 Warehouse or Parking Garage Revised November 2010 0 Other 1 Qualification Checklist Note: If occupancy type Is "Other' end fixture answer is checked, the number of fixtures c the apace is not limited by Code. Clearly indicate these spaces on plans. If not qualified. do LPA Cakulaborm. Ughtng Fixtures: (Section 1521) ij Check if 95% or more of fixtures comply with 1.2 or 3 and rest hue ballasted. 1. Fluorescent fodures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and trackinrlrlighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MN lamps < =150w c) electronic ballasts 3. LED lights. A TABLE 15 -1 Unit Lighting Power A►uowance Lx- i LPA (Wife) 0.91 Use' LPA (Witt`) Use' Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, instlb ons. museums, banks, churches? 1.10 Parking eareges 0.20 Convention center 1.10 Penitentiary and pttmr�roup Iii Occupancies 0.90 Courthouse Cafeterias, Last food establishments'. 1.20 Police and lire station 0.90 1.00 restau antslbars5 0.85 Post office Dormitory Dwettng Units 1.00 Retail retail barddng, map purses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 Stool buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, spaces 0.95 Theater, motion picture 0.97 assembly care clinic 1.00 Theater, performing arts 1.25 Health Hospital, nursing homes, and other Group 1 -1 and Occupancies 1.20 Trareipo 1ation 0.80 1-2 Hatet/motel 1.00 Warehouses 0.50 0.50 Laboratory spaces (all spaces not classified 'laboratory' shall meet office and other appropriate 1.62 Workshops categories) Laundries 1.20 Libraries' Manufacturing facility 120 1.20 -Main Submitted for Common Areas Only? Main floor building tobbiess(except mall concourses) 1.10 Museum 1.00 Common areas, corridors. toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Ta 1) In cases in which a general use and a specific use are listed, the specific use shall In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the budding official. This arrnInafion shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be Increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) .Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas. use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feel. 6) Reserved. 7) For conference rooms and offices less than 150f(2 with full height partitions, a Unit Lighting Power Allowance of 1.1 ar/ft2 may be used. B) Reserved. 9) For Indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit lighting Power Allowance for the tout area is 2.60 WI1t2. 10) Display window 0luminafron installed within 2 feet of the window. provided that the display window is separated from the retail space by wails or at least three - quarter -helgte partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighfing power allowance is allowed for merchandise display luminaires installed in retail sales areas that are spedflcaily designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items i and ill below, ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of Jewelry, crystal or china floor area. building The specified floor area for items i, ii, or Itt above, and the ad]clning circulation paths shall be identified and spedfl plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department exctudi ng major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, il, or Iii plus an additional 1.000 watts for each separate tenant larger than 250 square feet in area. The additional wattage Is allowed only if the merchandise display luminaires comply with all deer fmkswing: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two pants of track uttaolvnent) from the general This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately lighting, to be turned off during nonbusiness hours_ This additional power shall be used only for the specified hunlnaires and shall not be used for any other purpose. This additional lighting power is allowed only lithe lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height. is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) Jun :01 11 02:58p Ameriwest Electric 2009 Washington State Ene 1- 801 - 255 -3992 p.6 Code Compliance Form for Nonresidential and Multifernil Residential LTG -LPA Lighting Power Allowance 2009 Washington State Energy Code Compliance Forma for Nonresidential and Multifamily Residential Adjustments Revised November 2010 I°ate r I;-or Project Address I ioi SoU1't,i✓�w7�_ !Ma k Use this form If you are claiming any ceiling height adjustments for your Lighting Power Allowances for or� . The (B feet, Occupancy Desaiption should agree with the "Use' listed on Code Table 15 -1. Identify the appropriate Ceiling 12 feet or 20 feet) on wtnich the adjustment is based. The Adjusted LPA is calculated from this number and fro; the Allowed Watts per ft1. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted ting Power Allowances (Interior) Location (door planlroom #) Occupancy Description Alm Watts per fix " Ceiling Height for this room Ceiling Height limit for this exceptlort Adjusted LPA Watts perft2 J " From Table 15-1 based on exceptions listed in footnotes Jun:01 11 02:58p Ameriwest Electric 1-801- 255 -3992 • Q 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential p.7 2009 Washington State Energy Cade Compliance Forms for Nonresidential and multifamily Residential Revised November 2010 Project Address D , ' v� + . Ky i.e. I f G, (! The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer in the 2009 Washington State Nonresidential Energy Code. Date 0 Q ( j 7 iJ l , requirements Applicability no, ma.) l Code Section 'Component ; Information Required N Location on Plans Building Department } Notes (yes, LIGHTING CONTROLS (Section 1513 , 1513.1 Local controUaccess Schedule with type, indicate Iocatons 1513.2 Area controls Maximum limit Per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing overhead glazing indicate vertical glazing on plans Indicate overhead glazing on plans 1513.4 Display /exhiblspecial Exterior shut -off Indicate separate controls Schedule with type and features, Indicate location 1513.5 (a) timer wlbackup Indicate location (b) photocell. Indicate location 1513.8 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches . Schedule with type and features (back-up. override capability) Indicate size of zone an plans Indicate location of room master controls 1513.7 Hotel/motel controls 1513.8 Commissioning Indicate requirements tor lighting controls commissioning EXIT SIGNS (Section 1514) Z 1514 'Max. watts 'Indicate watts for each exit sign 1 5°0 ✓o k 4 b"'4 LIGHTING POWER ALLOWANCE (Section 1530 -1532) 1531 Interior Lighting Summary Form Completed and attached. Schedule with failure types. (amps, ballasts, watts per fixture '1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture hypes, lamps. ballasts, watts per llxture MOTORS (Section 1511) 1511 'Elec motor efficiency MECH -MOT or Equipment Schedule with hp. rpm, efficiency TRANSFORMERS (Section 1540) r1540 Transformers 'Indicate size and efficiency 1 jj I If "no" is circled for any question, provide explanation: 1 1 H R HARTING, JR./ CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F. RENTON, WA. 98057 PHONE (425) 271 -4242 JOB' .P.. At • TFI ill a JOB NO 1 r ICK. NDA LI i BY SUBJECT SHEET' D1 - 1 ECI L H EY4_1711 " -6W P5, E11'7T1 FL-WV /IXI"fR � �z) sX ,SU e711-1 "Pr- _ FILE COPY It No. }I°xa ,X_.1'18X id: EXI�T_2X -4 Egk,M .I u E)I9C .au LKU A _ SECT- laiLKNEW RECEIVED SAY 132011 'ERMITCENTER REVIEWED FOR CODE COMPLIANCE APP ROVED 'JUN 1 0 2011 City c BUILDIN f Tukwila G DIVISION 1.10r5! -WIPE (2) per, I' 1 lit 1«/WL`rPUCL Fes, EN 5 /a" 1U70xgaiZO) I✓\15 oc-1\1 -+LO-CP 1e4' Al ` I FS L 1rTiZ, a DP6��T AX 35/�'I. TP,GK �,( 5D SI4T M5T'L. -W% 1= : 7. TDP LiuEOF M \A/ALL Fx, Eu� gE`0UD DKTE Li /701.1 H R HARTING, JR. /CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98057 PHONE (425) 271 -4242 JOB' VC. + i r e flfir.3[Rj I1� 1I11N T 0” JOB NO1 bit- dry DATE' iirlY BY' •+ SUBJECT' r x+ CEIU J► 1 SHEET' SUSPE I_PW CEt 1.1 I.I� 2 Xt CEILI141-1 4, 4 TE O 2.5 R.,F- -rtLe;rW__L F1),(11RES _ 534AN I-htw EL\A/I e cx- mi x 24 "mac. Pte= 2 „L3 (0j) _ 2ca# PA= 2 0/0+0 r b ► sU I ` - V A O M IRE 64 X 2' x A' LAT e L lip? - C 4 SEISMIC. LD 7 -2co9 Imo, t-75C Ibis 1-05 _ U4E 4rri. C.Lkb 7 (1 I,L I�) LtbU -'Te UCU M Co H X6.1 T F�W (N2 hl piIr) FP < I epp4,ti1/41p I'L5a5 F > v ` ,TP '? n,? Fp DA 1 ,o (p1IE,3U,'i (') °2 ►5 / \ h ( J I 1 L- PSF .41A_.-2) 216+0 P roc ctglaS Ss = 1.421 c=1.0,461 CEUT b►v A� C ALcUL TED 1.Y-( 114 U t5 CS\usA, = tto rP -2,9- 1'2,. 5 -1 ��- k l to (S\ S09.0 co x w, '2AbD ko�A4 l'19a'(rz. * LLb1Ti --�-� t,Z•s x �Zx ►Z. ' 1-19 FA. iw-atril Fol114.V1 I IZE47 } S(1``c E'D 90° ,X15° VET 1 X41,1 o �0 2ob t`1 d_ H R HARTING, JR./ CONSULTING ENGINEER 212 WELLS AVE. S., SUITE F, RENTON, WA. 98057 PHONE (425) 271 -4242 JOB' DpW - ' - & 1 AL " JOB N01 O l I - 15 DATE' NI BY' SUBJECT' PARTITo1J SHEET' a _FULL L-II . ' ei 1'1!01..1 h = t DL - 2•b 6\616 1 % S'IVO, 2 1v 5lb' J L.&T5P- -L L4 F' = o.41 S (1+ 2 = ai- IL,D10111731(tZ Ph CZ"y1110 l 1 f' (ate 1 f VAIN LO` 160)k.■(:):-. .L5,12-f_Z 1)k= 8Dqe)q6 I 161)(c, IZ 26 &.A. ST 3c-DD S Q.=> ' 01 -350"1- %.,0,5-97; T I,tOZ� xr� - 6 = ,2 k () x Ca. -151 a5■ 11, £7m ;`-1 X o,%Z L-c4-luAcx. 6616. 55::)* our E3u► Log / = 2 -11 ►6t ft sce rw�. Q 4 "nco �►" � -ro tA E L tT .1-t STET _) C I �`` iT04 2.9 `A): 25;54 " �1 � 2 ILA` I` P , 2064 1i2 1 Tv mac► 1 t Li 1 X - 2I.4 13Z 7 P8 S fir' o� �tN E � � z" ,. A.1 'N111,4 rl 1 1 - - t ULT1 rrt scrtio 6 / AL- fI R HIARTING, JR. /CONSULTING ENGINEER r � 212 WELLS AVE. S., SUITE F, RENTON, WA. 98057 PHONE (425) 271 -4242 JOB: t_ JOB NO ON - DATE: SUBJECT' 06ZrIT11;44_1., so 1 1 MeV �i a (( BY' SHEET: E)-r5 pf GULkN 0.42 (SD sI.0 F )e -fDRE Far — C25 ISlIJ4 WNll. r 4FUDI=P 2 -0 1O2 TO EKE Or9rcR r/ &al:FIG:4? SUPFOC FAD 6KISVA431 ► EY751.1D Eri M I wkt,MLS EA►'44 LL= ( rot cokici Lial01 l) 7L- 21b 0wg, eTE01- t 1, DI I, 2 +6 �\ 2 ILL P11 l 5C , 12 +0 630- pe - (4+(� '2..(L= 2C. H- Cat L /& , .b5/)" 175.V L P &LIT 1 7 J5/ X 1 S /bu 47"1UiI ‘,,I toc. r- [200-SL 4 0.VAQ,_;iellY-3 '4A_CRILLI LAA, -rb` -1P2419.12-Aft, In 0 (e) 136 `� (2c\ id) it Li-36 -A C! HEW TO rxi sk _AO- ` ��D + 12) (a) = LS 71-F _ _U 5516 Mai 5 2. scRELO '7 E, 1up 1XL 14E134_ tat ) I -A. - 1 bE07 = Li 2,4# E� Z , 5ZEG. LAM-4 SEcr Ajo )(9(2. Gott ck Conterminous 48 States 2009 International Building Code Zip Code = 98188 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Data are based on a 0.05 deg grid spacing Period Centroid Sa (sec) (g) 0.2 1.429 (Ss) F--- 1.0 0.489 (S1) Period Maximum Sa (sec) (g) 0.2 1.473 (Ss) 1.0 0.507 (S1) Period Minimum Sa (sec) (g) 0.2 1.377 (Ss) 1.0 0.470 (S1) Conterminous 48 States 2009 International Building Code Zip Code = 98188 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site Class D Period Centroid Sa (sec) (g) 0.2 1.429 (SMs, Fa = 1.000) 1.0 0.739 (SM 1, Fv = 1.511) Period Maximum Sa (sec) (g) 0.2 1.473 (SMs, Fa = 1.000) 1.0 0.760 (SM1, Fv = 1.500) Period Minimum Sa (sec) (g) V.L 1.J/ / �JNIS, ra = I.uvu) 1.0 0.719 (SM1, Fv = 1.530) Conterminous 48 States ° '2009 International Building Code Zip Code = 98188 Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D Period Centroid Sa (sec) (g) 0.2 0.953 (SDs) 1.0 0.493 (SD1) K Period Maximum Sa (sec) (g) 0.2 0.982 (SDs) 1.0 0.507 (SD1) Period Minimum Sa (sec) (g) 0.2 0.918 (SDs) 1.0 0.479 (SD1) May 23, 2011 L • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Justin Hodges Downeast Outfitters 1187 S 1480 W Orem, UT 84058 RE: Correction Letter #1 Development Permit Application Number D11 -134 Downeast Basics —1010 Southcenter Mall Dear Mr. Hodges, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire has no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, J nQ Bill Rambo Permit Technician encl File No. D1 I -134 W: \Permit Center \Correction Letters\201 I\D11 -134 Correction Letter #I.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: May 19, 2011 Project Name: Downeast Basics Permit #: D11 -134 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11 x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please complete a Washington State Energy Code Interior lighting Budget. One has been enclosed with this review memo. 2. Please submit a floor plan that shows the main egress aisle that connects the front and rear exits. We prefer to show this as a shaded path with a side note stating emergency lighting shall be provided along this aisle with intensity levels per section 1006.4 IBC. 3. The portion of the egress that passes through the stock room is required to be separated from the stock area by a full or partial height wall. See section 1014.2 IBC. 4. is the rear stockroom open to structure above or is a hard lid planned? Please clarify and include framing details if necessary. Connection details to structure for the hard lid framing at the storefront are lacking in detail and it is difficult to tell what is existing and what is new. The engineers packet includes a section view of a portion of the new storefront. This detail should be on a structural sheet included in the plan set and that sheet should be stamped by the engineer. Larger cross - section views of this area may be better to show all connections and to differentiate between existing and new framing members. 5. Lighted exit signage needs to be shown on the egress plan requested in item 2 above as well as the electrical plan. The electrical sheet E2.0 shows what appears to be an exit sign with emergency bug eyes at the front of the store. Please add this fixture to the lighting fixture schedule and also add lighted exit signs to the two rear exit doors. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -134 DATE: 06/01/11 PROJECT NAME: DOWNEAST BASICS SITE ADDRESS: 1010 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: lul ding 'vision Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete . Incomplete DUE DATE: 06/02/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ttifA, Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/30/11 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -134 DATE: 05 -13 -11 PROJECT NAME: DOWNEAST BASICS SITE ADDRESS: 1010 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT : L 40-1/1 uilding 'vision � -� u lic w o �, Structural Fire Prevention PI ing 4)i 1s ibn Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 05-17-11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06 -14 -11 Not Approved (attach comments) ;K DATE: Permit Center Use Only CORRECTION LETTER MAILED: 5-XI- Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: uit Documents /routing slip.doc 2 -28 -02 4 a City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431.3665 Web site: hop://www,c/Jukwi/o.ways REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Rev ions will not be accepted through the mail, fax, etc. Date: C7 Response /( Plan Check/Permit Number: D11-134 o Incomplete Letter # E Response to Correction Letter 4 1 D Revision 4 after Permit is Issued Revision requested by a City Building inspector or Plans Examiner Project Name: Downeast Basics Project Address: 1010 southcenter Mall Contact Person: )0 )1(.1 ( Phone Number: 9/ "7; q621 5'47 Summary of Revision: At 'V,- Sheet Number(s): "Cloud" or highlight all areas af revision including date of revision Received at the City of Tukwila Permit C:enter by: Entered in Permits Plus on `‘app,icationa \ forms-applications on knave vision submittal Created: 8- 13-2004 Re , .sed: • Date: May June 1, 2011 Project Name: Downeast Basics Permit #: D11 -134 1. Completed the Washington State Energy Code Interior Lighting Budget 2. Updated sheets a. Added sheet A2.2; Egress Plan, Furniture Plan b. Detail 3 sheet A6.1, added 5 %" width to metal stud 3. Updated Sheet A2.1 a. Separated egress aisle from stock room with partial height wall. 4. Updated sheets a. See engineers comments b. 3.1 keynote 8; stockroom open to structure above 5. Updated Sheets a. Added exit signage to egress plan sheet A2.2 b. Added exit sign with bug eye lights symbol and note to sheet E2.0 • B R HARTING, JR./ CONSULTING ENGINEER r r 212 WELLS AVE. S.. SUITE F, RENTON. WA. 98057 PHONE (425) 271 -4242 THE rowatvilA te7ctig.PKRwsEizyrtiE EU iLfAktk PIV Is101.1 Co 4HEIJr PAP hixid IPt , 2DI I ITFH 11,) TI-f RF/42.42-TexteDNA 147 cP5MTD114 . QlN4i 1;»F •RuauRe ,'rE l ‘JoLQ-c., L .15i7 54 .Ror1\) I.... 25.91.41-1G.1 ley CN . AF' To PFTLEalliE FuasTl Ida S"f CfU 12F,M.I14 1 4 Z 4I 5kLfl kt,k) 5I.rt`P.'( CFLLttI& , E Y-1 q11. I �i P J IOW I S �l I i� per! L, 71-1e TRuci -1. _ ['MIL 1 e-aC i-I D C UT oI �,�1-1T �y �2.. S A/ 911 t Toe -r1ucCrurm.. Gmi L #,P17517 -- TO54-fi". /l5I, II+ nu 1-43,(7- �4- 12 ‘ 61,11E?. Contractors or Tradespeople P ter Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name RIMROCK CONSTRUCTION LLC UBI No. 602335573 Phone 8016767625 Status Active Address 11635 S 700 E, #100 License No. RIMROCL9107M Suite /Apt. License Type Construction Contractor City Draper Effective Date 10/13/2009 State UT Expiration Date 10/13/2011 Zip 84020 Suspend Date County Out Of State Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RIMROCL974Q5 RIMROCK CONSTRUCTION LLC Construction Contractor General Unused 12/9/2003 12/9/2005 Expired Business Owner Information Name Role Effective Date Expiration Date WHITE, RICHARD LYNN Partner /Member 10/13/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 SAFECO INS CO OF AMERICA 6610087 09/10/2009 Until Cancelled 08/10/2011 $12,000.00 10/13/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 TRAVELERS PROPERTY CAS INS CO C06683P767PHX10 03/01/2010 03/01/2011 $1,000,000.00 03/01/2010 1 CO CINNATI IINS CPP0812778 12/01/2008 12/11/2011 $1,000,000.00 01/06/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount NTAYE00401 6/2/2010 18.27.200(1)(e) RCW CONSTRUCTION INFRACTION Satisfied $500.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 06/14/2011 GENERAL NOTES: PROJECT LOCATION #316 — I xtt iI dun •-• • 6 ' Ill cnnek a Tukwila Gy. DOWN EAST OUTFITTERS STORE NO. Seattle (space 316) 25WKCNMlB Seane WA 98188 2o�24B Trop kr` t° j tc ..,�.st.ion 01 tippi'o O A THIS REMODEL OCCURS IN A MALL WHICH HAS NORMAL MALL BUSINESS HOURS. OTHER TENANTS WILL BE AFFECTED BY THE NOISE GENERATED THIS PROJECT. THE CONTRACTOR WILL NOTIFY LANDLORD AND ADJACENT TENANTS OF WORK BEING PERFORMED. SOME WORK WILL NEED TO BE DONE BEFORE OR AFTER BUSINESS HOURS AS DIRECTED BY THE MALL OWNER THERE ARE LIVING SPACES ABOVE AND PARKING BELOW. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE 2006 IBC COD, ® AND OTHER CURRENT NATIONAL, STATE, AND LOCAL CODES AS THEY APPLY. THIS MALL HAS AN ACTIVE SMOKE EVACUATION SYSTEM. THE �i E CO' - - TION WORK ON THIS UNIT SHALL NOT IMPS e - OPERATION THIS SYSTEM. TEM SERVES APPRO. Y4 SPACES. ELECTRICAL DISCONNEC e- E MAY SERVE THE SMOKE EXHAUST FAN, DAMPERS, ETC s • . FIELD V L ELECTRICAL CONDITIONS. THE SYST BE MAINTAINED IN AN OPERA • S NDITION DURING - THE REMO DEL 15 COMPLETE. ® DRAWINGS AND SPECIFICATIONS ARE NOT AVAILABLE FOR THE INDIVIDUAL O HVAC UNIT SERVING THIS SPACE. THIS UNIT SHALL BE INSPECTED AND REFURBISHED UP TO FACTORY SPECIFICATIONS AS PART OF THIS PROJECT. THIS HVAG UNIT SHALL BE MAINTAINED BY THE TENANT. ALL GUTTING OF LUMBER, CONCRETE, METAL AND OTHER BUILDING MATERIALS SHALL BE DONE AFTER HOURS. FLOOR IS POST TENSIONED WITH TOPPING. X RAYING OF SLAB MAY BE REQUIRED, COORDINATE WITH LAND LORD. ® WHERE ELECTRICAL OUTLETS, BOXES, ETC. WERE REMOVED IN WALLS THAT O ARE TO REMAIN, HOLES SHALL BE PATCHED F. WALLS PREPARED TO RECEIVE RECEIVE NEW FINISHES. ® ALL UNUSED EQUIPMENT, FIXTURES AND MATERIALS MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY. COORDINATE LOCATION OF DUMPSTERAND OR PORTABLE TOILETS (IF USED) WITH LAND LORD. ® ALL DIMENSIONS ON EXISTING WALL5 OR COLUMNS GO TO FACE OF FINISHED WALL. ALL DIMENSIONS OF NEW WALLS GO TO FADE OF STUD UNLESS OTHERWISE NOTED /ISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NO T2: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY �ettii� No, review Is errors subject ' of construction documents does m 4e does not authorize '�� e• of any adopted y dopt� Dods or Ong. Receipt - ;- { <, COpyffid •,i.i.1.0 :e :. -'- p., :1` x.11: �., B /� � j�/ y ��_ % -64...<1 . 6 - BY OF • ® ' • "- s2+ t y -" f ' ! T I f NORDSTROM I ! !ii!uIb; k'a` D t o; . ��rl� = _I ' W �.}J. TJw9niM� `� Te - - -° , :. ., r• 1 k� '' <Ij °tir ° �'� X�1111 `y �j r .il T� -�- D O 0 � ° o o � Imo 1- r� ', 'PI' i� � ` „' P,� i��' • = � ,q tl k . h ;' . 1... P, �,- aa L ¢e s, o. s, , > t' g'>+b,° , ` j} W p a- a Etr _ _t �e° n it ,c r RR. 6t �'. On!Fe..raseSt. a © s. I t I ten- - -- - I P. Sri Sln ta'- .._ -• w ,e �v t ? " - .. •�.�1p9 .. • n.eW UNST., .S IE0V+61 •_ LANDLORD: Christian Faltenberger Operations Manager P 9 Westfield Southcenter Shopping Center 2800 Southcenter Mall Seattle WA 98188 206 246 -7400 Scott Priester 'Tenant Coordinator Westfield, LLC 2800 Southcenter Seattle, WA 98188 206-802-6070 Office 323-578-3849 Cell 310- 689 -5702 - Fax Downeast Outfitters 275 W. Hope Ave. Salt Lake City, UT. 84115 Co a: Christopher Cockrell 801-680-7348 La La Johnson 801 - 721 -0825 Charlie Freedman 801 - 514 -2463 RECEIV cf� OF � ` A R,/� w:'7.0 i - �1: m ` ■'�j o ° • 11 ”' .�,. - - p 111 R 6 �'� ? . *,. �� / ��,\ '� �'" e' ' D * �� _ C * L - O� �� — X17 ! _ I. . _ -I'" _ �� _- - - PROJECT LOCATION #316 OWNER 1 TENNANT: VICINITY MAP: MALL KEY PLAN: 1 REVIEWFD FOR ARCHITECT: CODE COMPLIANCE APPROVED d�J�\ JUN 1 0 2011 City of Tukwila BUILDING DIVISIOW � •/fA� S / u /t / l•7RE r/ -- A %�lI(/ C2' G l� 5 JUN 0 1 2011 PERMIT CENTER PROJECT TEAM: APPLICABLE CODES EDITION BUILDING CODE INTERNATIONAL BUILDING CODE ARCHITECTURAL MECHANICAL CODE INTERNATIONAL MECHANICAL CODE A0.0 PROJECT INFORMATION PLUMBING CODE INTERNATIONAL PLUMBING CODE ELECTRICAL CODE NATIONAL ELECTRICAL CODE zoos ��� O A0.1 NOTES & SCHEDULES ENERGY CODE IN . ENERGY CONSERVATION CODE A1.1 FLOOR DEMOLITION PLAN FIRE CODE INTERNAT ONAL FIRE CODE ACCESSIBILRY CODE ANSI 117.3 A1.2 CEILING DEMOLITION PLAN - 's .'� C .. ,1 , lrjVAr REQUIRED FOR: [� eChanical bir Electrical L tumbing P city of Tukwila LBUILDING DIVISION A2.1 1 FLOOR PLAN OCCUPANCY USE GROUP: M- MERCANTILE, SALES OF CLOTHING A2.2 EGRESS PLAN / FURNITURE PLAN BUILDINGCONSTR1CTION7YPE 11-B A3.1 REFLECTED CEILING PLAN M.1 INTERIOR ELEVATIONS A4.2 FIXTURE DETAILS 0rLLOC°UPAN1 LOAD ss A5.1 STORE FRONT ELEVATION / PLAN DDANnTYOFEXITS REQUIRED: I A5.2 STOREFRONT DETAILS REVISIONS DATE �LISMIC2ONE: cA1EmuKY A6.1 PARTITIONS / CEILING DETAILS A6.2 CASHWRAP / BACKWRAP DETAILS Bid Set 5-2-11 Permit. Set 05-02-11 REV. Set 06-01 -11 STRUCTURAL Const. Set 00-00-00 CODE SYNOPSIS: S1.0 GENERAL NOTES, PLANS AND DETAILS AREA axUPANT OCCUPANT S2.0 SECTIONS AND DETAILS BREAKDOWN: (SO. FT.) LOAD FACTOR LOAD x EEVanoN,SECTION REF , e DRAWING NUMBER Ft FINISH KEY Fa oz FURNITURE KEY © ELEVATION, SECTION REF. .• ii / Z`fill� MECHANICAL 1. SALES AREA: 1 ". SCALE: 1' -0" 1622 30 SF OCCUPANT INCLUDES SALES FLOOR, M1.0 ENTRY, DRESSING ROOMS 2. BACK OF HOUSE: PLUMBING DATE: JUNE 1, 2011 C Of lb 1� BUILDING DIVISION 317 300SF/OCCUPANT WCLUDESSTOCK,TOILET EXISTING TO REMAIN 3.OTHER IMPROVED: 0 0 0 CORRECTION PROJECT INPORMATIOls `7O( DRAWING DATUM POINT xx DERTAAIWILN RERE (a AZx2> ELEVETAION CALL OUT l) KEYNOTE v DOOR MARK O ELECTRICAL 4. UNIMPROVED AREA: o E1.0 POWER PLAN E2.0 LIGHTING PLAN LTR# 5. GROSS AREA: 1939 55 (1'2+3.4) illcji IISIMP 1 41111Y1 AO .0 GENERAL NOTES: SYMBOLS: SQUARE FOOT BREAKDOWN: DRAWING INDEX: DOOR SCHEDULE T = DOWNEAST C = GENERAL CONTRACTOR L = LANDLORD E = EXISTING ALL DIMENSIONS ON EXISTING HAILS OR COLUMNS 60 TO FACE OF FINISHED P4ALL. ALL DIMENSIONS OF NEW PALLS GO TO FACE OF STUD UNLESS OTHERI'05E NOTED. SEE SHEET A6.I FOR WALL SECTIONS AND SHEET AI.O FOR TYP, PALL DETAILS SPECIFICATIONS: MARK SIZE (NOMINAL) WIDTH a HEIGHT THICKNESS DOOR MATERIAL FRAME MATERIAL RATING DOOR TYPE HDWARE GROUP REMARKS I NOTES FURNISH INSTALL REMARKS STOCKROOM T C L E T C L Oi re's 68• a It HOLLOW CORE WOOD WOOD A A ises+�vc n1E'1LrP 12'Anura,r rust le lr „DwsnwD,uauea WOK T. APPLY 26 GAUGE SHEET METAL TO INI7+Ep}FUOR AND E %TERIOR SURFACES Wf111 CONTACT CEMENT DRAWING. PROVIDE CERING • • O 2-4' x 6A' x It W CORE WOOD HOOD A A DUV Mb!ARUMD6-d-UWHHI.) -APPLY 26 GAUGE SHEET METAL TO INTERIOR RAW E ��AND EXTERIOR SURFACES WITH CONTACT ENT SALES I STOCK DOOR • DOTS: ARE ABOUT 4, THE BOTTOM OF A 12 QUART PAIL SOLD AT HOME DEPOT 5 THE TEMPLATE THAT 5 TYPICALLY USED. CREATE THE DOTS BY CURING THE CIRCLE FROM 12' TRANSFER TAPE PURCHASED FROM A 516N SUPPLY 5140P. APPLY TAPE TO WALL FIXTURE, SEAL EDGE WfiH LNIW N6, PAM, REMOVE TAPE FASTENERS: FOR PALL FIXTURES TO YKALL CONNECTION AND RECESSED W U ALL STANDARD FIXTURE TO HALL CONNECTION U5E THLUP52 PLUS' HIGH PERFORMANCE WOOD TO METAL 5LREW5. wuu.phMps04om 012 x 4' HALL STANDARD: STANDARDS FOR STOCK ROOM AND OUTFITTERS STORE SALES FLOOR REEVE 100 (F5T01 for 1 foot Iona) HEAVY DUTY ALL STANDARD. 1 INCH SLOT. 7 LONG. REEVE STORE EQUIPMENT 60.562-8442535 STANDARDS FOR RH 5LOT.VE NAILENF GOTH E. REEVE FIXTURE. 03 1 CONCEALED V ALL MIRRORS: 24' X 66' IS THE PREFERRED SIZE. BUT THE BEVELED EDGE MIRRORS CAN OFTEN BE FOUND A5 A STOCK ITEM AT 2T X66' FOR 665.00 CLOTHING HOOKS: MANUFACTURER • EVERBILT 053, FINISH • SATIN NICLEL FINISH, VENDOR • HOME DEPOT DRESSING ROOM BENCHES. SUPPLIER IKEA MODEL: LACK 601D4266 FIRE EXTNGUSHER MANUFACTURE • AMEREK MODEL= 8456, SIZE - 10LB., MOUNT TOP OF EXTINGUISHER AT 48' ABOVE FINISHED FLOOR. NOTE: IF THERE 5 AN EXI511N6 EXTINGUISHER THEN HAVE R RECHARGED AND TAGGED. DOOR ALARM FOR REAR DDT DOOR, WHERE USED.'VETE% FAX 500", OPOIER PROVIDED PROVIDE 36' SHELF IN BATHROOM FOR CLEANING SUPPLIES PROVIDE SIGN ON STOCKROOM DOOR TO EXTERIOR 'DOWN EAST BASICS' PROVIDE BROOM HOLDER PROVIDE PAPER TOWEL HOLDER IN BATHROOM DOOR KICK PLATE ON STOCKROOM DOOR COAX GABLE BOX IN HALL? DATA CABLE BOX IN PALL? DOOR DROP OPENER SIGN GRID IN FRONT WINDOW REVIEWEp FOR SIGNS INFO. �OQE COMPLIANCE dam° ED seton signs APPROV ��� 1 0 wo �� 1 L City of Tukwila BUILDING C DIVISION RECEIV J 't CITYOFTU _ JUN 01 1011 PERMIT CENTER ENTRY ALARM GATE S REAR SERVICE DOOR • ® 7-0'x8'8':1}' WOOD METAL 6 B 11�nsL0't��. IF USED AS AN BM FOLLOW IBC. 0142 EXCEPTION 02 FOR M OCC. i • . FLOORING VCT OR CONCRETE • O 7-0' z 68' a 1 WOOD METAL B C -REUSE EXISTING DOOR MD HARDWARE "�� VINYL BASE • • MANAGERS DESK • • Q 3,171613' x 1 1. AL METAL B 0 -REUSE E7OSTWG DOOR MID HARDWARE HOLLOW METAL, INSULATED DOORS IN METAL FRAMES. Cn ^ \ CD 11 w T 1 > /� T Fj,,,+ • r,rl ' > T O O SAFE • • ® 6,10 GLASS METAL !l CLEAR TEMPERED DOORS AND SIDELITES WI BRUSHED STAINLESS STEEL CLADDING AND HARDWARE. PROVIDE BACKING AT CEILING IN HINGE LOCATIONS FOR DOORS TO SUPPORT DOORS MICROWAVE/REFRIGERATOR Bl1LlJTW BOARD • • • • • DOOR TYPES HARDWARE GROUPS WALL SIDS, BRACKETS, SHELVE, • • /VARIES, �- 3 -/ / -3� ,f A CHANGE ROOM DOOR: 6 LADDER • TO REACH SALES • • KEYED 1- STORE ROOM LEVER, SCFDAGE ALIKE TO ALL CHANGE ROOM DOORS 2 - HINGE, BRUSHED MCIQE 1 -HEDGE, SELF CLOSING, BRUSHED NICIQE B SALES/STOCKROOM DOOR: TOILET ROOM T C L E T C L 5 1 ' EASED EDGE TRIM- -- OPEN —' .. \ \ m m ib, �i / �/ i ' 1� ■ —\ : m 20, L\ / i / l� \ \ CID : \r 1 -STORE ROOM LEVER, SGuAGE. KEYED ALIKE TO ALL CHANGE ROOM DOORS 3- HINGE, BRUSHED MCIQE C TOILET ROOM DOOR: ACCESSORIES • • DOOR 26 GA GALVANIZED SHEET METAL LLAOIN6. HOLD BACK FROM EDGE 1M' OPEN -- CEILING • • 1- PRIVACY LEVER, SCHLAGE. (USE EXISTING) 3 - HINGE BRUSHED NICKLE (USE EXSRING N ) D SERVICE EXIT DOOR: FLOORING AND BASE • • WAINSCOT • • TOILET ROOM DOOR • • ROOM DOOR 5TOCK ROOM I TOILET 36 REAR SERVICE DOOR 1- DETEX V40,EB EXIT ONLY, ALARM EXIT DEVICE 3- HINGE, BRUSHED NICJQE 1- DETEX WING PULL P268 ®CHANGE ©ROOM DOOR ® WALL SAS, BRACKETS, SHELVE, • • FINISH SCHEDULE GENERAL T C L E T C L KEY MATERIAL BY MANUFACTURER DESCRIPTION LOCATION / NOTES CONCRETE SAW CUTS/REPAIR • • CONCRETE FLOOR SEALER • • • P -1 PANT G.C. MATCHED COLOR'i1CONDEROGA TAUPE' BENJAMIN MOORE 0992, R3 1x4.0000, 513x0.000, Y3 4x'21.0000, GALLON EGG SHELL SEE INTERIOR ELEVATIONS DEMISING WALL STUDS • • BEHR BASE 2400, CLRNT 8 C F GALLON, EGG SHELL OZ 2 3 0 384th 37B 232 340 DEMISING WALL GYP. BD • • P -2 PANT G.C. MATCHED COLOR 'CLOTH GREEN' BEHR 5585 2300, CUNT B C 5 KK GALLON, EGG SHELL OZ 0 8 0 3 384th 28 108 140 108 $EE INTERIOR ELEVATIONS. TYPICALLY BACK WALL OF STORE AND MONO WALL FIXTURE pARTITIW FRAMING 5 GYP. BD. • • DOOR HARDWARE DISPLAY HARDWARE • • • • L a) c yam-+ = co v / N -1—+ (� CD CI) O CO C M cn lJ.I D_ N ill (n PO PLANT G.C. MATCHED COLOR'WSTAVIAN BLUE” BEHR BASE 3050, CRNT 8 E V GALLON, SEMIGLOSS 309ZIN 60 0 32 ODTSPFAELEVATIONS, BLUE 001008 FIXTURE WHEN BAMBOO TILES ARE USED. DOTS W CORNERS ARE TO FULLY WRAP. (SEE NOTES BELOW) CASH REGISTERS • • P-4 PLANT G.C. MATCHED COLOR' WIDE SIM BEHR: BASE 2400, CIRRI 8 E V GALLON, SEMIGLOSS OZ 0 0 0 th 132 338.5 39 BLUE BACKGROUND DEMOLIDW • • • FIRE EXTINGUISHERS • • P-5 PLANT G.C. MARTHA STEWAM,HOME DEPOT GOLD METALIC: PRECIOUS METALS SPECIALTY FINISH �F0RMULq 5[ralRht Gold B�sg M5�7]01.Lro tint USE MANUFACTURER ROLLER GR601 AND APPLICATION PROCESS. LIFE 8 SAFETY ALARMS • P-6 PLANT G.C. MARTHA STEWART, HOME DEPOT SIL •- LdETALIC: PRECIOUS MEfAIS SPECIALTY FINISH FORMULA =Base M517102, IDrt =MSL 374 Name= 'Tin' DOOR CASING AND DOOR EDGES AT DRESSING ROOM USE MANUFACTURER ROLLER GR601 CLEANUP • • P -7 PAINT G.C. BEHR FIAT BLACK PAINT CEILING WHEN OPEN CEILING 15 USED, SEE PLANS FOR BEGINMNG ELEVATION. SECURITY SYSTEM • • P-8 PANT G.C. BEHR SWEET MOUSSES, BY BEHR.O 10130 -23 STORE FRONT, WHERE USED P-9 PLANT G.C. RUSTOLIUM HIGH PERFORMANCE SPRAY ENAMEL, ALUMINUM 7515 USED AT THE EDGES OF METAL PANELS ON RECESSED WALL STANDARD FIXTURES EXT. STOREFRONT T C L E T C L P -10 STAN G.C. MINWAX BEHR: CLEAR BRUSHING LAQUER CLEAR SEMIGLOSS, WART BARRICADE • • P -11 PAINT G.C. BEHR FLAT WHITE PAINT CEILING WHEN OPEN CEIUNG IS USED, SEE PLANS FOR BEGINNING ELEVATION. STRUCTURAL FRAME WINDOW SYSTEM • • • • FLOORING F•1 CONCRETE, SEALED G C EPMAR / KRUK° INDUSTRIAL WATERBOURE FAST DRY EPDXY TOPCOAT STACRETE, SS3700-CLEAR SALES FLWN AND UNESSING NOUNS PROVIDE 2 COATS F-2 EXISTING TO REMAIN EXISTING TO REMAIN PROVIDE MATCHING MATERIAL TO REPNR EXISTING FLOOR AS NECESSARY ENTRY DOORS AND HARDWARE • • F-3 CARPET G.C. PER TENNANT CARPET TILES 18X18 SALES FLOOR AND DRESSING ROOMS where used TILE IN DISPLAY WINDOWS TILE ON ENTRY VESTIBULE TILE AT BULKHEAD STOREFRONT SIGNAGE • • • • • • • • • F•4 STAINED CONCRETE G.C. AMERIPOLISH OR BRICKFORM CHOCOLATE BROWN COLOR, ACETONE BASED, MUST USE NON WATER BASED SEALER SALES FLOOR AND DRESSING ROOMS where used F-5 TILL G.C. CONTEMPO, CERAMIC 11LE CORP 801 262-1717 AVENUE ONE. AU05 COFFEE SHOP. AVAILABLE IN 24x24, 18x18,12:24, 2,24,6124,4x24 GROUT FE TILE G.C. CERAMIC TILE CORP (801)262 -1717 MONO MEERRCUR AVAILABLE W 20' x 20' GROUT.MAPEI =98WATERFALL — CELING REVISIONS DATE C-1 CEILING GRID AND TILE G.C. MATCH EXISTING MATCH EXISTING SALES FLOOR 100, CHANGE 101,102,103 BULKHEAD • • Bid Set 5-2 -11 C -2 PANT EXPOSED TO STRUCTURE, NO PANT G.C. MATCH EXISTING MATCH EXISTING NEUTRAL PIERS • • Permit- Set 05 -02 -11 BASE REV. Set 06-01-11 T 1 5}' WOOD BASE (SITE VERIFY SIZE) G'C' 5 }' SQUARE WITH EASED EDGE. OR MATCH EXISTING 5 }' SQUARE WITH EASED EDGE. OR IF THERE IS EXISTING TRIM VERIFY WITH OWNER IF IS PREFERRED TO USE. SALES FLOOR AND CHANGE ROOMS. BARRICADE GRAPHICS • • 1-2 4' RUBBER BASE G.C. ROPPE TP RUBBER WALL BASE, BROWN, COMMERCIAL, 4 Xi RASF700CRIP4CT O H AT CASH WRAP SALES AREA T C L E T C L CODS!. Set 00-00 -00 CAS CEILING TILES METAL TSAR CEILING GRID GYP BD. • • • • T -3 It WOOD CASING G.C. NA PROVIDE PER PLANS SHEET A4.1 UNLESS MATCHING EXISTING PRODUCT ON SITE. SITE VERIFY SIZE IF MATCHING EXISTING) CHANGE ROOM DOORS T-1 31' CROWN MOULDING G.C. NA PROVIDE SHAPE PER PLANS SHEET M.1. CROWN MOULDING TO BE INSTALLED FLAT NOT AT AN ANGLE Electrical Requirements for Sensormatic gates at entry to store Dedicated Circuit / 120 VAC Operation / Power Fuse: 3A, 250V slow-blow Current Drew: 2.OA peak System hardwired in conduit 24 Hour unswitched ..,....3 wire, external ground preferred Less than O.Sv between neutral and ground. Power to be pulled to base of primary pedestal at floor level near wan. Pedestal will mount a few inches from wan / doorframe. Electrical contractor to hardwire directly into post. ' Three Exit systems may share one 2OAMP circuit. • Any concealed or buried conduit will be provided by the sites' electrical contractor, and is optional to the performance of the system. Many stores have their electrician do a preliminary rough wire pun in advance of our installation. Then the electrician can meet our le the day of the work to compete finish wiring Pouf Y pe ring and actual termination. Tom Grismer (SENSORMATIC) 303-880 -4000 SCALE: I" = 1' -0" • • T-5 5}' CROWN MOULDING G.C. NA PROVIDE PER PUNS SHEET M.1 CROWN MOULDING TO BE INSTALLED FLAT NOT ATM ANGLE LA IRATE PANTING • • DATE: JUNE 1, 2011 LI LAMINATE SURFACE G.C. PIONITE PLASTIC LAMINATE SURFACING. COLOR= HP359 THUNDERSTORM'. GRAIN TO VERTICLE. FROM FLOOR TO CEBNG CONCRETE FLOOR, GRIND • • WALL PAPERI METAL WP -1 WALL PAPER G.C. PER TENANT TENANT PROVIDED, CONTRACTOR INSTALLED WALL FU(iURE, SEE ELEVATIONS WOOD TRIM, MIRRORS • • N OT E5 & 5 GH E D U L E 5 WP -2 WALL PAPER FLATS G.C. PER TENANT TENANT PROVIDED, CONTRACTOR INSTALLED. THESE ME 16 X 18' X }' CARDS. TO BE INSTALLED WITH CONTACT CEMENT AND JOINTS CAULKED. WALL FIXTURE, SEE ELEVATIONS WOOD TRIM, FIXTURES • • M-1 26 GA. SHEET METAL G.C. HVAC SUPPLIER CONTRACTOR PROVIDED, CONTRACTOR IINgSTTAILLEED .pTNO�BVE4INSFTyALLLLED pWIITHHpCON ACT t FCONTRACTOR DRESSING ROOM DOORS AND RECESSED WALL ERE USED AUDIO SYSTEM • : A42 18 GA SHEET METAL G.C. HVAC SUPPLIER CONTRACTOR PROVIGEDAI WSTALLEO. TO BE INSTALLED WITH CONTACT CEMENT. STOREFRONT SEERS R MILLWORK FUTURES M-3 HAMMERED METAL G.C. EASADE RETAIL SALES = HOME DEPOT FORMED PLASTIC THAT LOOKS UKE HAMMERED METAL PATTERN = TRADMONAL 1. COLOR= CROSS HATCH SILVER STOREFRONT EXTERIOR, AT METAL PANEL JOINTS. SFF Fl FVATIONS A5-1 CASHWRAP / BACIM'RAP • • M-4 HAMMERED METAL G.C. FASADE DEPOT SALES= HOME DOT FORMED PLASTIC THAT LOOKS UKE HAMMERED METH PATTERN =LOTUS. COLOR= SMOKED PEWETER FACE PIECES TO OVERLAP CORNER A O rfi` TABLES • • G1 }' CLEAR TEMPERED GLASS POLISHED EWES GC. _ ALUMINUM EXTRUSIONCONTRACTORPROVIDED, CONTRACTOR INSTALLED. STORE FROM GLASS AND FRAME. CONTRACTOR PROVIDED AND INSTALLED GLASS CHAT HOOKS • • DOOR 5HEET METAL • • EXISTING MALL BULKHEAD — , 11ll111_ 111111`1111111 11 111111 X1,_11 ._ . \ F \ 0 0 /— CENTER DOORS ON i STOREFRONT GLASS DOORS. . r/1 C V " •1 /11 lrT�1 �1 TI 0 Q 0 /- 6 \ / 28 / - -/ O BARRICADE ELEVATION / 80' -10• r 76'-4. 4 21'' ------- ---- -- --- --- --- --- ----- f -+--'— -- -------- --- -------------- - --- -- F —r'—� _ 3_ -/ ! r �/ OB TYP. i �// //r \ \ 1 �� '( \ \ v^ \\��,\ , / y WOOD FLOOR — ;)� © WO REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 10 2011 City of Tukwils BUILDING DIVISION f� L CONCRETE 0._, CARPET , 4 �_ ® u n - , o © ©0 m O O 1 Seattle South Center SPACE 316 Seattle, Washington O`\ •\ ' �< r I�I 0 TYP. . \\ i T/ /. ) J .- ‘ �\` �. J / r -- — A, I \ / \\4� „ __ RECEIV CITYOFTU LA JUN 0 1 1011 PERMIT CENTER FLOOR DEMOLITION PLAN }' °1'-0' 0 REMOVE EXISTING DISPLAY FIXTURES. WALL STANDARDS, SHELVING AND FURRING TO FACE OF DEMISING PARTITION. ® REMOVE EXISTING FLOOR FINISHES THROUGHOUT LEASED SPACE TO LANDLORDS CONCRETE SLAB. CLEAN AND PREP FOR NEW FLOOR FINISH MATERIAL. (CERAMIC TILE IN SALES AREA, VCT TILE IN STOCK ROOM AND TOILET ROOM) O REMOVE EA 5TING CEILING, FRAMING , U&HT FIXTURS, HVAC GRJU EIS, DIFFUSERS AND DUCTWORK SEE MECHANICAL DRAWINGS FOR ADDMONAL INFORMATION. O REMOVE FETING GYP. BD SOFFITS AND FRAMING. O REMOVE EXISTING DOORS AND PARTITIONS, SHOWN DASHED. © EXISTING PLUMBING FIXTURES TO REMAIN. O EX5TIN6 STOREFRONT, GLASS, GLAZING FRAMES AND DOORS, METAL STUD FRAMING AND FINISHES TO BE REMOVED. REF A5.1 FOR NEW STOREFRONT SCOPE OF WORK AND DEMO REQUIRED. BO EXISTING DEMISING NULL TO REMAIN. DO NOT DAMAGE EXISTING RATED ASSEMBLY. PATCH AD REPAIR AS REQUIRED TO MAINTAIN FIRE RATING. OR LEASE UNE 10 EXISTING SERVICE DOOR TO REMAIN. VERIFY HARDWARE IS SUITABLE FOR REMISE. 11 EXISTING ELECTRICAL PANELS AND ELECTRICAL BOARD TO REMAIN. REF; ELECTRICAL SHEETS. 12 REMOVE AND DISPOSE OF EXISTING CASH WRAP, SALVAGE ELECTRICAL 50 CIRGAT CAN BE REUSED. 18 REMOVE AND DISPOSE OF EXSTING ROLL UP DOOR AND DOOR HARDWARE. 11 ADJACENT COUNTERTOP EXISTING CONSTRUCTION 1. PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE AUTHORITIES HAVING JURISDICTION AND ALL COMMONS SET FORTH W THE LEASE. 2 CONTRACTOR TO VERIFY FIELD CONDITIONS. PROVIDE OWNER WITH LEASE SPACE DIMENSIONS, AND NOTIFY TENANT, PROJECT MANAGER AND DESIGNER OF ALL DISCREPANCIES BEFORE PROCEEDING WITH WORK 3. REMOVE AND DISPOSE OF ALL EXISTING MATERIALS SHOWN ON PUN UNLESS OTHERWISE NOTED. A. SEE KEYNOTES FOR ANY NECESSARY FLOORING REMOVAL 5. ELECTRICAL MD MECHANICAL UNES THAT ARE NOT USED AND ARE NOT INTERFERING WTTH NEW CONSTRUCTION SHALL REMAIN. 6. REMOVE ALL ELECTRICAL AND MECHANICAL LINES THAT WTERFER WITH NEW CONSTRUCTION. REFER TO ELECTRICAL AND MECHANICAL SHEETS FOR INFORMATION ON EXISTING ELECTRICAL AND MECHANICAL EQUIPMENT TO REMAIN FOR RE-USE. ALL UNUSED ELECTRICAL WIRING SHALL BE PULLED BACK TO THE CLOSEST JUNCTION BOX ALL UNUSED PLUMBING LINES SHALL BE CAPPED W THE WALL OR BELOW FLOOR EXERCISE EXTREME CARE DURING DEMOLITION AS TO NOT DISRUPT OR DAMAGE ANY EXISTING UTILITIES OR SPRINKLER UNES WHICH SERVICE ADJACENT TENNANTS. GENERAL CONTRACTOR WILL BEAR THE SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE. B. COORDINATE THE REMOVAL, DISCONNECTION AND/OR CAPPING OF ANY UTILITIES WITH LANCLORDS FIELD REPRESENTATIVE. PUCE MARKERS TO INDICATE LOCATION OF DISCONNECTED SERVICES. B. WHEN NECESSARY HVAC SUBCONTRACTOR TO INSPECT EXISTING CONDITIONS PRIOR TO DEMOLITION AND DETERMINE WHETHER ANY COMPRESSOR REFRIGERANT LINES ARE PRESENT THAT NEED TO BE PROPERLY DRAINED (TO EPA STANDARDS) PRIOR TO DEMOLITION. 10. NO DEMOLmON IS TO TAKE PLACE ANYWHERE OUTSIDE OF THE TENANT LEASED PREMISES WITHOUT THE APPROVAL OF THE LANDLORD AND CORONATION WITH NEIGHBORING TENNANTS. 11. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMODATE NEW WORK PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE(S). PROVIDE BRACING OR SHORING AS REQUIRED. GENERAL CONTRACTOR WILL ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT, DAMAGE OR INJURY. 12. PROVIDE, ERECT AND MAINTAIN BARRICADES, LIGHTING, AND GUARD RAILS AS REQUIRED BY APPLICABLE REGULATORY ADVISORY TO PROTECT OCCUPANTS OF BUILDING, WORKERS, AND PEDESTRIANS. 13. GENERA. CONTRACTOR IS RESPONSOOI F FOR THE REMOVAL OF ALL UNUSED, ABANDONED AND EXTRANEOUS ITEMS. BURNING MATERIAL ON SITE IS NOT PERMITTED. 11. EXISTING UFE SAFETY SYSTEM I ALARM SYSTEM, 0 EXISTING AND REQUIRED, SHALL REMAIN AND BE RECONFIGURED FOR NEW TENNANT 6UILD.CUT. DO NOT REMOVE, MODIFY ONLY. G.C. SHALL VERIFY PRIOR TO DEMOLRONAIONSTRUCTION. AND /OR AND FIXTURES TO REMAIN. - EXISTING CONSTRUCTION AND/OR AND FIXTURES TO BE REMOVED LINE OF CONSTRUCTION BARRICADE. REVISIONS DATE Bid Set 5-2 -1 1 Permit. Set 05-02 -11 REV. Set 06 -01 -11 FOR BARRICADE ELEVATION SEE PROVIDE MINIMUM 6070 DOOR CENTERED CENTERED ON STORE FRONT OPENING CODSt. Set DO -00-00 SCALE: i• = 1' -01 DATE: JUNE 1, 2011 DEMOLITION PLAN P LA N A1.1 LANDLORD NOTES DEMOLITION PLAN KEYNOTES DEMOLITION LEGEND DEMOLITION NOTES 1111111 111111111 I�IIIIIII � {p I- 1IIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIII I�IIIIII IIIIIIIIIIIIIIIIIIIIIII�I) WINDOW WINDOW f� O CO) ■ u 1 11MM1 EXISTING STOREFRONT ELEVATION EXISTING STOREFRONT ELEVATION (approximate) ltWJC..I;�> I ,�' / 1 1 c I 1 I 3 / '1 , ' 1-1 - J 1 ( 1 1 1 I _.J7-.-V-J4. ' -n 1 - 1 1 I L� � _ 1 11-- ' 1 CY' � \` I 1 1 1 I t _ 1- C:1 , :-.1 �x___�x ` ‘1',..1- J I's:: \ /, ‘ `— /1-�] \ `C- z T = I I i I t-1 ,,, I x i 7 /t- in- c l Jr a 1 �_� b-- CIJ Cif LIII i / ZI i PJ 0 g� 1 -, _ ' - - -f0-1- 1 -'ate A� 1`1 Y- -r - -fy c T I 7 �i .E• '1- 1 �h, 1-4 t -- t--- 1--- l �) 'i,J �/ . ., rE I1'-8' A.F.F. EXISTING CEILING HT. — BARRICADE RETURN 1414115 TO BE CONSTRUCTED ram 2 PANELS 50 THAT NHEN THE NEUTRAL PIER 5 EXTENDED TO THE LEASE LINE 014E OF THE PANELS MAY BE REMOVED. CEILING DEMOLITION PLAN t . PO" 1 I- CEILING DEMOLITION KEYNOTES REFER TO ELECTRICAL REFLECTED CEILING PLAN DRANINGS FOR 0 CLEAN ALL SUPPLY AND RETURN AIR GRILLS. TYP. LIGHT FIXTURE SCHEDULE O ALL UNUSED EQUIPMENT. FXTURES AND MATERIALS MUST BE COMPLETELY REMOVED AND DtISTING CONSTRUCTION AND /OR AND FIXTURES TO REMAIN. REVISIONS DATE DISPOSED OF PROPERLY. O ANY OPENINGS IN THE LANDLORDS BASE BUILDING MUST BE PROPERLY PATCHED AND SEALED BY THE LANDLORDS CONTRACTOR O REMOVE AND PROPERLY DISPOSE OF SUSPENDED CEILING SYSTEM. EXISTING 6055114 CTION AND/OR AND FIXTURES TO BE REMOVED Bid Set 5-2-11 Permit. Set 05-02 -11 REV. Set 06 -01 -11 Const. Set 00 -00-00 0 REMOVE LIGHT FIXTURES. REUSE 4 EXI51155 FIXTURES IN THE NEW 570CK ROOM. REUSE EXISTING ELECTRICAL CONDUIT WIRING FOR NEW LIGHTING AND POWER PLAN. VERIFY O WITH ELECTRICIAN. REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 10 2011 • City of Tukwila BUILDING DIVISION RECEIVQ_ artf OF TIJIMIA JUN 0 1 2011 PERMIT CENTER SALE: ;• -1' -0• DATE: JUNE 1, 2011 CEILING DEMOLITION PLAN A1.2 LANDLORD NOTES FLOOR PLAN KEYNOTES PARTITION LEGEND • 87-10* REVIEWED FOR CODE COMPLIANCE APPROVED JUN 10 2011 DownEast Outfitters 10' -11' 69' -1 1 • City of Tukwila 4 4' " 6, • C 11• 6' 2' :• '_ • 13,-6• 3. -7" 4" S, • 4. 6" •' , 1 6' x D' WKL FUTURE 6' x D' MIL FUCTURE 5'X5' RECESSED POLL STANDARD FIXTURE SUTYULL FUTURE ACCESSORIES FIXTURE 4' x D' YtALL `IXT (� r - - - - 6' x 61YVALL FUCfURE � . ING DIVISION DOUBLE 35'D" METAL STUDS — — . 7 1- 7 L_ I 1 I 1 I 1 1 1 L _ I 1 1 1,-8" 2'," 10 10 10 10 10 10 Ark 13 25 -10y" -- - - O T G 4 el "e`i O l_ _ 1 ' 7 1 1 I �i 1 J 1 ' SALES o— 1 1 __, ZGlaRDHRIM r r N I F 1°"1 1— —11- I- h / 5) /� L, \ ® ,\\ �I ® STOCK 13 YI w II LL <4 A41 2> SO. Fr.. 1627 1 1 o FLOORING: Fb ail x 3 ���y r�J- -I 1 iv v tl Y z o N II 1 I 1O'.)Ju-i � CHANGE ROOM (TYP.) a � _ _ J L_ 50. `T.31T O FLOORING: F2 1 ® Alli " �5 A4 1 6> O v r r O FLOORING:r�� II -.1 tl Y I LJ II t 1 � COUNTER TOP TO 15 TYP. WITH J 016' O.L. SUPPORTING DOUBLE 6'166A. METAL "C" JOISTS IT 0.C. PY 314" FIRE RETARDANT PL,'Y'10oD PLAT'ORM AND 51D'GPY BD CLG. �/ \� \ - F-I 13- C 2 3 1 1 '� .351 1 i _ 11.1: o J 117.1; 904.3, 904.3.] �, _ _ / J ' 0 / ....... ...... ....... J° J 2O 1 - 1 . � 0, (.19) 70 1 10 L I+' 6 1 1 2 ' ( I - +- H--.= SPACE 316 Seattle, Washington T2- 4,$" 4'-8" 4'-6" �•/ D' z D' MALL FIXTURE 6' SXD' RECESSED YIALL STANDARD FIXTURE 9' 3 -11 "I, 3,74" 17 x 6' VIAL. FIXTURE 18,8Y4* / PROVIDE 60" MINIMUM DISTANCE FROM ANA. TO 12, ' f/i / / 1 1• 22,4* • / / 5 67• EDGE OF 514K. EXISTING /NALL DV 516" 6TP. BD. TO ROOF STRUCTURE ABOVE RECE,VE® JUN 01 2011 PETcE FLOOR PLAN ' r '''0' 1 O CASHWRAP AND BACKW 14 RAP, OWNER PROVIDED. REFER TO SHEET A6.1 AND ELECTRICAL THERMOSTAT (OWNER VERIFY) DRAWINGS FOR POWER STUB LOCATION AND OTHER REQUIREMENTS. GLUE TO FLOOR WITH2 CONSTRUCTION ADHESIVE AND INSTALL RUBBER BASE (T2)BASE AT TOE KICK 15 INSTALL HOOK PER DETAIL T A4.2, CENTER BETWEEN DOORS, PROVIDE SOLID BACKING O REPAIR WALLS A5 NECESSARY (TYP.), SMOOTH KAU, 90d CORNER BEAD. INSTALL NEW 16 INSTALL BASE PER ELEVATIONS A4.1 DRYWALL AT NEW DRESSING ROOMS. . - a ;y,.,n.....:,:.- -_ • - - ___-- ._...",y.m. - -r.• r r, •NTRAGTOR INSTALLED WALL TYPES NOTE: SEE PLAN OR Y`:ALL ELEVATIONS FOR YNALL HEIGHTS EXISTING WALL TO REMAIN. PATCH AND REPAIR AND FINISH REVISIONS DATE ■ 1 TO SMOOTH WALL TEXTURE. SEE FINISH SCHEDULE. SEE CONSTRUCTION NOTES. � NON PARTITION: 31" 20 GA. METAL STUD WALL N/ Bid Set 5-2 -11 Permit Set 05-02 -11 0 PAINT WALLS AND COLUMNS PER ELEVATIONS SHEET. AND SCHEDULE SHEET P0.1 5E5 x - i i_TIoa r:.- - -_ - ...NR1 0 REFRIGERATOR AND MICROWAVE 19 ALARM GATES AT STORE ENTRY. OWNER PROVIDED AND INSTALLED. CONTRACTOR TO 0 LOCATION OF ELECTRICAL PANEL INSTALL ELECTRICAL TO BASE OF UNIT. SEE SPECIFICATIONS SHEET A0.1 0 TELEPHONE TERMINAL BOARD. SIGN TIMER TO REMAIN 10 FIRE ALARM PANEL 0 MANAGERS DESK, OWNER PROVIDED. 21 PROVIDE CHRONOMITE INSTA FLOW WATER HEATER MODEL = 58301120 Y. 120 VOLT, 3600 WATT, 30 WATT INSTANT WATER HEATER 0 SAFE - G.C. TO SECURE TO FLOOR. OWNER PROVIDED. ENSURE THAT NO OUTLETS ARE PROVIDED BEHIND SAFE. 51TE VERIFY WITH OWNER BEFORE ATTACHING TO FLOOR. O LADDER HOOK @ 1' A.F.F. 0 FIRE EXTINGUISHER /fix o FIXTURES: OWNER PROVIDED. INSTALL FUTURES PER ELEVATIONS SHEET �4 11 MIRROR, TRIM AND LIGHT FIXTURE PER ELEVATIONS SHEET. PROVIDE 314" BEVELED EDGE IN ` 1 CHANGE ROOMS AND GUT SANDED EDGE ON SALES FLOOR. \ ' • • - , -- NDARDS INT• . . - -. , ' - ' . DRYWALL 24" 0. - - •• • -4.. EE WALL 13 INSTALL STOCK ROOM WALL STANDARDS INTO EXISTING STUD FRAMING 32" 0.C., U5E SPECIFIED FASTENERS. SEE WALL STANDARD DETAIL SHEET A4.1 REV. Set 06-0311 -RATED I `C4 TYPE X GYP. BD. BOTH SIDES. SMOOTH WALL FINISH, PAINTED. WALL TO TERMINATE 8' A.F.F. 2 NON PARTITION: ONE LAYER 1" GYP. BD. ON ONE SIDE Const. Set 00-00-00 -RATED ONLY OF 4" METAL STUD FRAMING. WALL TO TERMINATE 12" ABOVE EXISTING SUSPENDED CEILING HT. = ( NON -RATED PARTITION: 5 1(2" 20 GA. METAL STUD @ 16" O.G. �y N/ t,'' TYPE X GYP. BD. BOTH SIDES. SMOOTH WALL FINISH, PAINTED. WALL TO TERMINATE AT EXISTING ROOF DECK. d 2 NON -RATED PARTITION: 51" 20 GA. METAL STUD WALL W1112" SCALE: i" = 1' -0" DATE: JUNE 9, 2011 FLOOR PLAN f 4.l"t " CEMENT TILE BACKER. BD. ALL SIDES. TILE PER ELEVATIONS. A2.1 LANDLORD NOTES FLOOR PLAN KEYNOTES PARTITION LEGEND 5e,e, f 2•j r jta499 * dLw S w ni• Y-'tocet 'Fe 011S ADJACENT TENANT . DownEast Outfitters ( . cif 7 N � 'lll' • I I xl __ q I = P - -, - --- — 1'lu�� j EXTERIOR 1 a_ • 1 _ SPACE 316 Seattle, Washington ji ADJACENT TENANT REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 10 2011 City of Tukwila BUILDING DIVISION FURNITURE AND EGRESS FLAN 4.- Iv 1 O EGRESS AISLE, EMERGENCY LIGHTING SHALL BE PROVIDED ALONG THIS AISLE WITH INTENSITY LEVELS PER SECTION 1006.4 IBC 01 PENDANT MOUNTED INTERNALLY ILLUMINATED EXIT SIGN WITH 2 HEADED EMERGENCY LIGHT AND 1 i HOUR BATTERY BACKUP. SEE SHEET E2.0 2 WAY e = ;:- - - 4 ru' I. - - - - - - b'X7.10'TABLE 3'-4' X 3'- 4' TABLE - - - - -� .. -, P05 DESK CJ5HPIRAP UNIT • .; -- -- t.. - . - BACK/NW UNIT ;._. -. PENDANT MOUNTED INTERNALLY ELIMINATED B TTE SIGN BACKUP. 2 HEADED EMERGENCY LIGHT AND t I HOUR BATTERY BACKUP. DELNERIES OF OWNER FURNISHED ITEMS WILL BE TO DOCK THE UNLOADING OF 1HESE REELS IS INCLUDED W CONTRACTORS SCOPE OF WORK 36' WIDE EXITING PATH OF TRAVEL IF < 50 OCCUPANTS REVISIONS DATE Bid Set 5-2-11 RECEIV A CITY OF TU JUN 01 2011 PERMIT CENTER Permit. Set 05 -02 -11 REV. Set 06-01-11 Const. Set 00-00-00 SCALE: i' = 1' -0' DATE: JUNE 1, 2011 EGRESS FLAN FURNITURE /�/ /�) A2.2 CEILING PLAN KEYNOTES FIXTURE SCHEDULE GENERAL NOTES • 1 IP' • -.• O O x O p 0 x 1• th•• ir 4 0 II x x x ■ x x sP / sP p ► �•I•� ■:�I��r ■/ /I x 1 x ■ x x ____a_ O O REVIEWED FOR CODE COMPLIANCE APPROVED REFLECTED CEILING PLAN JUN 10 2011 City of Tukwila BUILDING DIVISION VESTIBULE CEILING PLAN RECEIV GPTYOFTU U► JUN 01 ZOII PERMIT CENTER tO NEW 2X2 CEILING TILES AND TRACK O INSTALL HALO OR HALO COMPATIBLE TRACK. OWNER TO PROVIDE HEADS AND BULBS. INSTALL LIGHT AT S6" O.C. • SOUND AND SECURITY SYSTEM BY OWNER • INSTALL SIGN PER ELEVATIONS • INSTALL SX9 WIRE GRID AT CEILING O ALIGN EXISTING FIRE SPRINKLER HEADS TO NEV LOCATIONS AND HEIGHTS. Oi PROVIDE SPRINKLER SUPPLY LINE INTO ENTRY VESTIBULE CEILING, CENTER DOWN PIPE ON VESTIBULE. PAINT FLAT WHITE TO MATCH CONTROL ZONE CEILING. • CEILING OPEN TO STRUCTURE ABOVE. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FUTURE SCHEDULE 111 SUPPLY AIR DUCT ® RETURN AIR DUCT EXHAUST FAN 5P SPEAKER CAMERA FIRE SPRINKLER HEAD LOCATION EXISTING CEILING/FIXTURES TO REMAIN NEW CEILING GRID TRACK LIGHT HEAD WAC JTK -764 (JUNO COMPATIBLE) OR WAC JTK -764 (HALO COMPATIBLE) ® 2747 FLUORESCENT LIGHT 0 RECESSED CAN 1. FIRE SPRINKLER SYSTEM SHALL BE DESIGN/BUILD AS PER GENERAL CONTRACTOR ALL AUTOMATIC FIRE SPRINKLER SYSTEM ENGINEERING, MATERIALS AND INSTALLATION TO BE BY LANDLORDS DESIGNATED FIRE SPRINKLER CONTRACTOR IF REQUIRED AT TENANTS EXPENSE. 2. FIRE PROTECTION SPRINKLER SYSTEM SHALL BE APPROVED BY BUILDING MANAGEMENT. PROVIDE FULY CONCEALED HEADS AT STORE FRONT ONLY, PROVIDE SEMI-RECESSED HEADS AT BALANCE OF BUILD OUT. UPRIGHTS Q STOCKROOM WI OPEN CEILING. SPRINKLER HEAD ESCUTCHE-ONS AND COVER PLATES SHALL BE WHITE TO MATCH CEILING. 3. REFER TO ENGINEERING DRAWINGS FOR ELECTRICAL, LIGHTING AND HVAC WORK COORDINATE MIY DISCREPANCIES WITH TENANT PROJECT MANAGER. 4. BACK TO BACK SWATCHES ARE NOT ALLOWED. OFFSET A MINIMAL DISTANCE WITH A METAL STUD BETWEEN OPPOSING SWITCHES. 5. SWITCHES SHOWN AT THE SAME LOCATION SHALL BE GANGED ON THE SAME COVER PLATE S. COORDINATE WITHAL TRADES INVOLVED TO ENSURE CLEARANCES FOR ALL CEILING RELATED ITEMS NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT AS EXISTING. 7. ALL LIGHT FIXTURES, HVAC EQUIPMENT AND DIFFUSERS SHALL BE SUPPORTED FROM TOP CHORD OF STRUCTURAL JOIST ABOVE. 8. HANGER WIRE AT SUSPENDED CEILING SHALL BE B GA AND 10 GA AT SUSPENDED ACOUSTICAL 11LE CEILING. WIRES SHALL BE ATTACHED TO STRUCTURAL STEEL ONLY, WITH U.L. LISTED CLAMPS. DO NOT ATTACH SUPPORT WIRES TO MECHANICAL EQUIPMENT DR PIPING. SCREWS ARE NOT PERMITTED IN THE METAL DECKING. REFER TO CEIUNG DETAILS ON DETAIL SHEET. 9. CEIUNG SUSPENSION SYSTEM SHALL BE ATTACHED AT TWO ADJACENT WALLS. MAINTAIN TWO SIDES UNRESTRAINED. 10. PROVIDE CEILING ACCESS TO AL LANDLORD EQUIPMENT, CONTACT LANDLORD FOR REQUIREMENTS. RENEW CEILING ACCESS REQUIREMENTS WITH TENANT PROJECT MANAGER PRIOR TO INSTALLATION OF ACCESS PANELS. 11. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE AND SPECIFICATIONS. CEILING PLAN KEYNOTES REFLECTED CEILING PLAN LEGEND GENERAL NOTES Seattle South Center SPACE 316 Seattle, Washington REVISIONS DATE Bid Set 5-2 -11 Permit. Set 05 -02.11 REV. Set 06 -01.11 Const. Set 00-00 -00 SCALE: }" = 1' -0" DATE: JUNE 1, 2011 REFLECTED CEILING PLAN A3.1 • • 1 WP 1I- 1 P-1 H 1 WI I- PS 41 LJ 0 °0000° ° ° ° °°° 0000 ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° ° °° 0000 ° PAPER ° ° ° °0o °° ° °o °° ° 0 POLKADOT ° ° CO 0 0 1 L,, 1 �, �, , Nt,l REVIEWED FOR CODE COMPLIANC APPROVED Ni e 17 z 0' MULL FIXTURE 0705' RECESSED WALT. 0' z 0' WALL FIXTURE STANDARD FIXTURE 'JUN 2011 -II yT_1 10 • City of Tukwila wil 5ALE5 AREA INTERIOR ELEVATION .•t���/I�$� a ., 1=1- I P-5 I -0,iiiihr0.131SPLAY Call. TILE -{FS I ak _= C SPACE 316 Seattle, Washington [ cr. l ,L.: ouopx TILE J - II ..12 \ 6 MIRROR 4X5' RECESSED WALL STOCK ROOM STANDARD FIXTURE I P-5 I- I T -1 I- - 1 B A5.2 STOCK ROOM ELEVATION }•`'4 6 SALES AREA }•`1'4' SALES AREA INTERIOR ELEVATION 3 '`''4• 2 INTERIOR ELEVATION 4 REVISIONS DATE Bid Set 5-2 -11 Permit. Set 05-02 -11 REV. Set 06-01 -11 I LA I- I P.5 H 1 M'1 1 1 P-5 I- I P-1 I I P-1 I— I P-3 I— I 1.41 - 1 P-5 I- 1 P -2 1 1 P-3 I. r R�VEIV Coml. Set 00-00 -00 , °, °,°,°, °, ° LAMINATE \ ,,,,,, 6OLD oo;ao ° EMBOSSED P EL � SCALE: } " =1. -0. ---- - -- L� r _■_ o °o °o °o GREEN PAINT DATE JUNE 1, 2011 --- --- -- I I ELEVATIONS ____21 -'� -■ • N -\ _ .. _ L. ■EM -- _ _- `R \ T 'CITY OF TU LA (� 0' z O'WALL FIXTURE V z 0' MULL FIXTURE 5'X5' RECESSED MALL ACCESSORIES 1' z 0' NALL FIXTURE 0' z 0' MULL FIXTURE STANDARD FIXTURE I PS I - I T -1 FIXTURE JUN 01 2011 PERMIT CENTER A4 STOCK ROOM ELEVATION }•`''4• 5 d SALES AREA INTERIOR ELEVATION • iv. � 1 NOTE 4 DOTS BACK WALL ONLY. FOLLOW A5 CLOSE P't 1 P -3 I-- AS POSSIBLE TO PATTERN ACCESSIBLE BENCHES. SHALL COMPLY WITH LODE OF FEDERAL REGULATIONS, ADA STANDARDS FOR ACCESSIBLE DESIGN. 435.4 BERGH Evert/ eueasmle dressing room shag have a 241n ty 431n bench Poxd to the well CHANGE ROOM FRAMING NOTES: - egg the longer d6nenslon. The tench PROVIDE 2X650LID BLOCK AT BASE shag be ranted 151 to 191n atwe the OF MIRROR AND HOOK LOCATIONS finished floor. CE61NG LEVEL LEWNG LEVEL GELLING LEVEL CEILING LEVEL \ SHOWN BY DASHED LANES ON ELEV5 ELEVATIONS (TYP ) FOLLOW AS CLOSE AS POSSIBLE TO PATTERN SHOWN DETAIL/IX ® 0 -rte v O O 0 O DOOR STOP. PROVIDE— BALKING 11.1 I • - E^ 3 OPEN - -\ DOOR — 266.4 °o SHEET °7: w METAL OPEN ,- SOLID IN4NALL BLOCKING (DASHED) SECURED TO STUDS COAT AND FLAT HOOK .2 MANUFACTURER•EVERBILT6 F I N I S H SATIN NICLEL FINISH VENDOR• HOME DEPOT 24'a2P %66'Xj'BEVELED EWE MIRROR GLUE TO WALL . / 4-" // -2 / DOORSTOP- rMIRR02 \ BACKING CENTER ON YXALL -� 1111-.'" l r: ri m •\ MIRROR - CENTER ON WALL 5MOWN O Q 0 0 _ O O O 0 -• A • (DA 'B) ` C v -, ,J�,. ^' ti ^ t e yi' .., V -1p O 0 0 O 0 0 0 0 0 O 0 0 0 0 O 0 0 0 Q 0 O 0 0 0 \ ' HOOK - HOOK /J 4-8• PROVIDENICKLE OR CHROME \_.� -\ TYPICAL CHANGE - \ CHANNEL MOUNT AT BOTTOM 441 - TYPICAL ADA / / / - - 5'_2 , / ./ EDGE ONLY. / 5' -2 ROOM ELEVATION ELEVATION ELEVATION ELEVATOR FLOOR CHANGE ROOM FLAN ® © 0 IN-WALL BLOCKING - . O O WASHED) SECURED STUDS NOTE THIS DRAWING 5 TO SHOW GENERAL REQUIREMENTS OF THE ADA APPROVED CHANGE ROOM. SEE SHEET A2.1 FOR EXACT WALL, DOOR AND FIXTURE LAYOUT. t DownF Outfitt CHANGE ROOM BACK WALL ELEVATION •''� DRESSING ROOM FRAMING PLAN (TYP.) i' "''.o. I 12 4 PROVIDE 7 SNEETROGK REVEAL 2201 FRAMING r , 51• CROWN •5 1 T [ M-1 F F- WAl STANDARD (PROVIDE �' %j' GROOVE 1 BEHIND EACH STANDARD 1 DRYWALL WALL TOP AND SIDES 4' -5 1 /4' - - / FRAMING PLAN FRAMING PUN 2-6• 6-// REAR 510E STANDARD /1/ i w o., :1. '...1 / / x ; m° 26 GA SHEET METAL -�• PARTICLE B0. I I I I r !z 4'PLYCLEAT, 40 deg ANGLE s }' CROWN © —7b GA SHEET METAL L l I=1 GRAIN n �' y1 j \=_ \ 4, 1 y sue• 1 . / FRONT SIDE•LAMINATE CONSTRUCT BENCHES FROM I -1/6' 1 PLYWOOD CORNER BENCH ADA BENCH �z4'PLY LLEA7. 40 deg ANGLE >` PLYW00D �' PARTICLE BD. VARIES \ ar•r��R 103 VERIFY i• • 1.-7 3' • 1'-0' Seattle South Center SPACE 316 Seattle, Washington -5 1/4" BASE ELEVATION PLAN WALL STANDARD (PROVIDE ' %�' GROOVE BEHIND EACH STANDARD STANDARDS FOR RECESSED MU. REEVE 3M' TOP 3/4• TOP 7214 RAILS 2X4 RAILS PLASTIC LAMINATE: LAMINATE TOP AND FRONT ONLY LAMINATE TOP AND FRONT ONLY PIONRE HP354 COLOR = THUNDERSTORM GRAN TO RUN LEFT TO RIGHT AS YOU LOOK AT THE BENCH FROM THE FRONT. STUD FRAMING DRYWALL STUD FRAMING CONCEALED R 1 INCE. - b STANDARD.1 INCH SLOT. - PLYWOOD LWALL FF SECTION 1• = 3' ELEVATION i• • ILO' r ur -1'-0' - ©SECTION © O CHANGE ROOM BACK WALL ELEVATION (where used) 1,0' CHANGE ROOM BENCHES k=1.0 RECESSED WALL STANDARD FIXTURE 5 11 i 3 i-.1.0. DEMISING WALL -- eY2 / 51/44/ - 6' 6' - RETURN SIZE 1' 1' 1' 1' 1' 1' 1' CO' ¢ > f °` ° ° ° °1 ° ° ° ° °°° ° ° ° 1° ° ° ° I= ° ° ° ° ° 1 ° ° ° ° ° ° '1 ° ° ° ° 0 ° 0 ° 0 ° 01° 0 0 0 ° ° ° ° _o ° ° °;_ ° ° ° ° ° 0 RECESSED WALL STANDARD - - -- w SHEETROGK .. -- -\ %i TRIM- _ SHEETROGK -- FRAMING -- - - - - -- REVIEWED FOR CODE COMPLIANCE APPROVED N10 2011 s�U1• i ` City of Tukwila _ ►- _ , --LINE OF RETURN �„` - GLEA7.SEEPETAL / t•vnwwcwnrzownsvn a ono ° ° 0 0 I 1 0 ° ° 1 d ' ° ° ° ° ° ° 0 ° 0 ° \ -- ;i ?i, �- MONO FUTURE HOLE R,,W,,,, -- nm,e 3 i rn wacsvrozr- . -_ sczerese«om i_ -- rwswim.oros ' — t. =aas. °t "tnr nnurnnl FRAMING 17 GLA555HELVES, 35/6• METAL STUDFRAMING -1' .; J ° ° ° ° -o • ° ° T ° o ■ ° ° ° ; • ° ° ° �\ oipmr, —1 /.- VARIES / ,�"`wwa, \ y1ALl -- -- .a,�,.,oa zrz,zzae I— �. '•Xi•T M 11 o °_o 0_0 ° -p / VARIES MIRROR r43•� \ / /51N mart nvn11vnt.ranro wo W.V. REVISIONS DATE / r a. PLIGILL I s s r �a� w sorm a«nzor n S�CTION V.CTION . NON REAR ELEVATION FRONT ELEVATION Bid Set 5-2 -11 Permit. Set 05 -02 -11 ©'.LnoN C um D O E 1 3' 3" 3• �ro,zr,.. r =3• r =3• REV. Set 06 -01 -11 "T" FIXTURE 1/7.1'-0• 3' =1-0' 10 113 TRIM DETAIL BO '"r- II _- c 2 • - - BURNISHED METAL REDUCER STRIP art Or Const. Set 00-00 -00 / 7 1/4" - _ _ -/ / 61/2"- /- 2� -8 -/- /?'_/ JUN 01 -EASED EDGE PERMIT 2011 ENTER HOOK, SEE SPECIFICATIONS SHEET AO 1 1 • • v SCALE: } "= 1' -0" 4" TILE FLOOR CEMENT RAMP USE LATEX MODIFIER TO INCREASE ADHESION. DATE: JUNE 1, 2011 TILE FLOOR /� 4 �O� \ - -\ _- _ BASE \ CROWN \ T�, 3�' CROWN TRIM -_. 24•X66•X }•SANDED EDGE MIRROR GLUE TO WALL. PRONDENICKLEORCHROME CHANNEL MOUNT AT BOTTOM EDGE ONLY. \ x m n :71 w FIXTURE DETAILS LM LONG. FLOOR \ - CONC.. FLOOR S/6• MDF -1 HOOK DOORCA5T \\ ' \ CROW " 3 ILA' AT 'a „ \ -= \SALES - \ --- -- m 1 P'2 I GOAT AND HAT HOOK MANUFACTURER = EVERBILT 153 FINISH • SATIN NICLEL FINISH W VENDOR DEPOT FLOOR \ STOCK ROOM PROVIDE FULL STUD BACKING WHERE NEW FRAMING OCCURS AND TRY TO HIT EVERY OTHER STUD OTHERWISE AT STANDARD MIRROR 'd \ :> 2 \ \ REDUCER STRIP, METAL(where used) 3-- 4- 9 REDUCER STRIP, CEMENT(where usedT`' – 8 HOOK DETAIL 3 `'� - WALL STANDARDS 3•`''4. 3•`''4- 3 `' -0• • 1 6 MOULDING PROFILES 5 MIRROR DETAIL • xyzT, gl c{ - E.g IJ t E z1t-i1: fUJ .KH N2 ' { us, flog. 5 �•-ar .. 1Y1 _s,5 "0wE?7, PAW 1p EA. TUDTnp - - =5/8"4.V./ RJ' I #* �� EA, , � w�,% F -6 _ Ct it CL bV /11 0 4-a O EN 2 �° IFaF 4 ,1�/�11 .. �' ,, 1 T.O. STOREFRONT 5164V/E7 TILE -hl1 IV 1��/ �1 i /L?!� DISPLAY CEILING I u V fik 120124T.O. VESTIBULE — BRUSHED METAL FRAME -- Q,(,, �7� �V/ V le.�' a l 518 /A ,Og S_rUI //V 1Lo Ki. F �� _ 176• IV ,/ �{ D�� 7 L 7 C Lti/ O V V 1S V Lam/ 1S 2] �/ T basuc�s 51GN PER MALL REQ. q T/ /�Y "1 _ ).M _ _ ( r 9/S .W ✓ 0i"a5D/914TMCI- LL 1 • .iEclyu455DOORS ' 9'-0" TIka TDP BD1T: 0.-. D � � - - - -- 7 C F5 C 5b 6U55 / R r; .. _ - - _ - . , F INSH RR. 7 C 6L/55 JOINT C EXI9,T .0 LICI -I __ . S AELT:- r I _M DP ,y� V�` 1 ✓• � L I u E OF \dALL EXTEIJ9 V �YT D � ' I ��N ` C m c o ) b• BR US HED METAL FRAME •METAL STORE BASE TO FRONT B , y M —I MATCH GLASS 1J 6LA55 -' r. / �� REVIEWED FOR CODE COMPLIANCE APPROVED JUN 10 2011 I I Lou) i STOREFRONT ELEVATION '!' /I�Z //��v 4/ • t ', ✓. FL yq . _.• O .x '''G> • / ✓ % S. �� �j ;: ti' so, City of Tukwila BUILDING DIVISION REVISIONS DATE Bid Set 5 -2 -11. Permit. Set 05-02 -11 REV. Set 06-01 -11 r I I � r- - - I r -n Const. Set 00-00 -00 J� I Ell _ _ = a T' I R SCALE: }" = 1' -0" DATE: JUNE 1, 2011 43) L� _ _ _ - - L b'MTL. STUD FRANIN6 / B 10 F.0.5. _._ _._._ .�/ RECFEIV�CE.�yn./y' �I 1 1 O• " " "� UN O 1 2011 JUN CENTER STOREFRONT PERMIT A5.1 STOREFRONT PLAN rr•ra I 17 GLASS SIDEUTE __ _ - — 6•XIr X20 GA STUD Sr XIr X C • — - ^ _ _ \ 166A STUD 5r X it X 16 GA C STUD DOUBLE —,-- (IN FRAMING MOVE) TO MOLD DOOR HINGE . — STOREFRONT GLASS —114' REVEAL - TILE TILE BACKER —3/4• FIREPROOF PLYWOOD - FRAHING -EXISTING FLOOR SLAB, MTL TRACK VI/ HUM X.DNI 97 P6515 193d O.L. MAXANDI7FRONEfTHEREND. b•X 1r X20 GA STUD ON LAYOUT - - - -- I' TILE BALKER BOARD. INSTALL MOTH- APPROVED fASTENE0. b' O.L. TILE. SEE ELEVATION FOR TILE TYPE DownEast Outfitters t .4 t _ _ i i Y 4 e < C A c 516' STORE FRONT&LASS — ' 1 3I4' ALUM. EXTRUSION BELOW — -- -1 '}.1° i SECTION AT ENTRY 1}•'° b DISPLAY WINDOW PLATFORM t''o 3 LANDLORDS ROOF CONSTRUCTION �� II TEIUNT TO ___II STOREFRONT TO REMAIN (DASHED) 1 1 EXISTING BULKHEAD, HATCHED - �-_ REMOVE DECORATIVE FIN AND - BALKING ONLY NEW STORE FRONT - .. , 2'-G• f7.10• �_ 3' CONSTRUCTION �• - - --) I 1 % 1 1 _- _ u/ DEMO EXISTING METAL REVEAL • - TYPICAL EACH SIDE OF NEUTRAL LEASE LINE - PIER i l / -- WV GYP. P. 1 • �- - NEUTRAL PIER EXTENDED lf\LIi _ J III / � / / / -- 4 ! I* - - � .mno �/�ra FACE OF NEUTRAL - PIER BEYOND _ _ _) I � SPACE 316 Seattle, Washington _ 14 - -- - — -- --- ; REQUIRED BASE UT REQUIRED AT NEUTRLL PIER AT III- _ 5f6' GYP. 352' STUDS . BD. NEW SUSPE REVIEUVED FOR Imo— f\ 1 I - '" 1 / i 21' -10' 37-6' -JI AWMINUM MALL STOREFRONT � LELLIN6 N CODE COMPLIANCE CE DEMO EXISTING STONE ' FINISH - FUL HEIGFfT OF EXISTING NEUTRAL PIER OUTLINE OF BULKHEAD ABOVE- DEMO FINS '-� FRAME•Al16N TO LEASE LINE 34E.J { - GLASS -- LEASE UNE APPROVED JUN 10 2011 ° City of Tukwila BUILDING DIVISION Battle South Center 3, ____� (3 . NEUTRAL PIER RIGHT SIDE PLAN VIEW °''° SECTION AT ENTRY _..., S i1' 15 ±11-17 x2fi / • LANDLORDS ROOF CONSTRUCTION • STRUCTURAL COLUMN BEYOND -�� Afari REVISIONS DATE Bid Set 52 -11 ,,,__— 4. EXISTING BULKHEAD, HATCHED - REMOVE DECORATIVE FIN AND - Q BALKING ONLY R STORE FRONT -., -- /_ 7�' ,2'-10• f 3' CONSTRUCTION j OUTLINE OF BULKHEAD - - - -- ABOVE. DEMO FINE I 1 1 Permit. Set 05-02 -11 REV. Set 06 -01 -11 I INEW DEMO EXISTING STONE - FINISH - FUL HE GHT OF - ,)Tn - - LEASE UNE -- 1 _ __ GLASS COnSt. Set 00-00 -00 EJ05TIN6 NEUTRAL - ------- PIER r ALUMINUM MALL STOREFRONT FRAME - ALIGN TO LEASE LINE aREwxr =MI �����, - J :oo OMR, oEL.1O-I' _ I I --1 -- ---- -- -- - -- -- -- -- - - - -' --- ', .J 1T STONE BASE -A5 �`,r `u"°""` rT SIGN PER MALL • -- I REQUIREMENTS oW.,I. ° FACE OF NEUTRAL PIER - -- -- AND LEASE LINE BEYOND NEW ENTRY - VESTIBULE COLUMN Fd — • SCALE' }' = 1'-0' • • ve•6YP. BD. wER DATE: JUNE 1, 2011 V - REQUIRED AT NEUTRAL PIER -- NEUTRAL PIER EXTENDED 95/7 STUDS MI NEW SUSPENDED • -FlRE SPRINKLER DROP LEWNG - - • - .R RECEIVF� ... -- -{ FS I KVIII CITYOFTU L•A -- TILE OVER 17 CEMENT OD. it OVER 3-511Y JUN 0 2011 - - -- — GLASS DOORS ■/�- p. ^( PERMIT C. - 52' GYP. BD. - - - - -- AD.NCENTTENANT STOREFRONT TO REMAIN (DASHED) 5TOREFRON' DETAILS A5 .2 NEUTRAL PIER LEFT SIDE PLAN VIEW '� "-0 4 SECTION AT ENTRY }.Ra EXISTING ROOF STRUCTURE TO ROOD& EXISTING METAL ROOF DECKING — j / /// / J© TIT UNDERSIDE OF FLOOR OR ROOF ABOVE I__ _ -1 I 26 GA TTP 5I/7 DEEP LEG NTL TRACK ANCHOR TO I UNDERSIDE OF STRUCTURE AT 24' O.G. MAX AND 17 I FROM EA END OR BRACE AS DETAILED IN 416 I ' _ _ _ ' I - - -1) —_ • — LINE OF GEBJNG WHERE OCCURS (EXTEND GYP HD. UP TO DECK IN STOCK ROOM AREA) - - -' m. - DownEast Outfitters DEMAND HATER HEATER POWER TO HEATER - %� 38 MIN 12 min _5151 MIN 39 -41 / COAT lb 6A DEEP LEG DEFLECTION -- - _ - - -- TRACK (1 �' MIN. DEEP LEGS). CONNECT TO ROOF STRUCTURE YUTH (2)6125CREW5 ®16'O.C. EACH OF STUD (1)6125LREY4IN— EACH FLANGE OF EALM 5TUD , \ Gd' �� o 0, .- NIRROR Tf min , T, 42 MIN q II II I _ - - - -� (1) LAYER r GYP. BD. AT BOTH SIDES OF WTI STUD FRAMING. SECURE TO MTL FRAMING NU 1' TYPE 5' SELF TAPDJG STEEL 5LREW5 PLACED CO.CAVJNG EDGES OF --1� BOARD AND 170.0. IN THE FIELD F THE BOARD. '+ " / -'.. n '�-\ U �� _ �• I!(Cff � � "I 20 GA STD. LEG MIL TRACK Pi/ MOM-0Ni 92 PD515 @3-0- 0.C. MAX AND 17 FROM ETHER END. - - , WATER SUPPLY -� RESTROOM — '\uuuu�SSS RESTROOM / —/ ,18 - 18 BASE TREATMENT. REFER TO INTERIOR ELEVATIONS. -f FINISH FLOOR - REFER TO FINISH SCHEDULE. 1 1 1 1 1 1 1 RESTROOM ELEVATIONS 3 ' • 1,0 5 NOT USED 3 °1° l NON RATED DEFLECTION 3' •'° 5 NON -RATED PARTITION, GYP BD. BOTH SIDES •',0' 3 UNDERSIDE OF FLOOR OR ROOF ABOVE STRUCTURE / / / / / / / / / / / //i NOT PROVIDE 'BOX BEAM' MADE NTH STANDARD TRACK AND STUD TO RESIST LATERAL LOADS AT TOP OF CHANGE ROOM NULL DOUBLE 31' X 16 GA STRALK SECTION I - 1.5' DEEP LEGS ' \ 20 GA TYP 91' DEEP LEG ML TRACK ANCHOR TO UNDERSIDE OF STRUCTURE AT 24.0.0. MAX. AND 17 FROM EA END UNDERSIDE OF FLOOR OR ROOF ABOVE- M‘ITI 3 r METAL STUD DIAGONAL BRACE ®4D' O.G. ALTERNATE DIRECTION. ATTACH TO STRUCTURE ABOVE FOR LATERAL SUPPORT ONLY. - -- -� 31' 20 GA METAL STUDS TENNANT DEMISING PARTmON OR EXTERIOR WALL U^NERE OCCURS) - - MECHANICALLY FASTENED PER MFR RECOMMENDATION aa 4 R12 SCREWS (BOTH FADES) ® 21.0.0. ,�_� FASTENERS AT 17 0 L. TYP. STANDARD TRACK, 517E AND GAGE A5 REQUIRED - -- : \ 4 m LINE OF CERING N6/ERE OCCURS (DREAD GYP P. UP TO DECK IN STOCK ROOM AREA) Ui y.. C 0 +L-+ 0 0 CI) N 4--F as CO SPACE 316 Seattle, Washington D GA HANGER HIRE 04,0' 0 . C . - CHANGE 6' OF END OF CARRYING CHINNED — MA N RUNNER N' O.L. t 17 31'X1 %20 GAL5TUD ®21 O.L. (1) LAYER r GYP. BD. AT BOTH SIDES OF WI STUD FRAMING. SECURE TO MIL FRAMING WI 1' TYPE 5' SELF TAPING STEEL SCREWS PEALED D' O.C.AONG EDGES OF —., 1 Imo_ (1) DYER I' GYP. BD. AT STORE SIDE OF MTh STUD ��- FRAMING. SECURE TO MIL FRAMING Nu 1' TYPE 5' SELF TAPING STEEL SCREWS PLACED D' O.CN.ON6 ED6E5 OF BOARD AND 17 O.L. IN THE FIELD FINE BOARD. _ — LINE OF GELLING INHERE OCCURS (EXTEND GYP BD. - UP TO DECK IN STOCK R0014 AREA) - ' MAN BEAM 11' X 1 k X 1H' SLOTTED, BOARD AND 17O.L.IN THE HELD F THE BOARD. -.. . - -_ MIL TRACK N U HILTI X -DN132 P6515 ®3'-0' 0.D MAX AND 17 FROM EITHER END. V 20 GA STD. LEG MTL TRACK NY NILnX.DNI 32 POSIS HEAw DUTY COLD ROLLED STEEL 0 Q MATCH 17861156 v o= o e O 0 0 v o 0 0 o ®3'P O.L. MAX AND 17 FROM EITHER END. BASE TREATMENT. REFER TO INTERIOR ELEVATIONS. — -��II FINISH FLOOR- REFER TO FINISH SCHEDULE. -- - - - , BASE TREATMENT. REFER TO 177 F.F. 1 • MATCH EXISTING I INTERIOR ELEVATIONS. — FINISH FLOOR REFER TO FINISH SCHEDULE. \ • CROSS RUNNER® 46' O.G. EXISTING CONC. SLAB 1 I I 1 \ PARTITION BRACING•'a 6 SUSPENDED CEILING DETAIL N.T.S. - 6 NON -RATED PARTITION, AT CHANGE ROOMS '� •'" 4 �•'¢ 2 H NON -RATED PARTITION, GYP BD. ONE SIDE 1 REVISIONS DATE Bid Set 5-2 -11 / / \} . • W6ERHIIEATEALII FERAVER MAW TEE - — STAMMER EAR TOMNNTNN PERIMETER TEE SPAGN6 _. . MNN TEE ORCRO55 TEE 'S4'MAXIMIM - MERE WISER CURES FENOANT.MWN1EDl1GNfFCRViR4 \ FouRwlESS- TED AND Foams V Mg.* MORE TINA 56 OW -OREM IM TOM FROM Les. 94411 BE SUPPORTED FROM EACH OILER STRLGTVRE. USW FIXTURES YEIEMN6 -MAN TEL Permit. Set 05-02 -11 STRUCTURE ANGER CURES AT 4' O.G. WM RREGTTN. MO MORE TAN It 01lfOFf{OMB, TYPXx OUTOFiLUMB.PROVm! WINTER SLOPING CURES TRAPEII AS REOD. TO I/ REV. Set 06-01-11 000 I i WOO OBSTRUCTIONS MAW/4N MANGER PARE 1 LESS 1NN S6 LES.BIW1 SE FASTENED TO STRICTURE MTN TWO SLACK HIRES, Const. Set 00-00 -00 MINMUM. SP/LING ANOWhClTV ' I 1 ) • \ MOTE: THIS TO - - CROSS TEE ,-,—' —/ / \ • •�/-�/�NR rhS,[n wu ,r,..,�w N' ONiE4fr REVIEWE SOFFK REQUIRED roRNFwwau CODE COMP`IANCE APPROVED LIGHT F BRAGNG R: E6M6 SYSTEM TITN CORNER OF TEMi {vf CEILING SYSTEM LOCATED 6DOC.EKM — Or —LEWNb SYSTEM) - -- PERMERRARItf10N5L SUPPORT L = _ PERIMETER SUPPORT GENERAL SUPPORT DATE JUNE 1, 2011 PARTITION/ M15C. DETAILS JUN 10 2011 City of Tukwila BUILDING DIVISION LATERAL BRACING RECEIV �-- pp. CITY OFTUIeNLA JUN 01 2011 PERMIT CENTER 6 • 1 1?• 1'-0' :\ N— x- 1 N >4 L -3 L -1 DownEast Outfitters 1 1 I < 1 I 1 \ L -1 — �— RUBBER BA5E APPLIED AFTER INSTALATION OF QUADRAPLEX RECEPTACLE (MOUNTED TO INTERIOR ELECTRICAL AND CASHNRAP 15 SECURED TO FLOOR. -- PROVIDE 12" X 12" PARTITION AT BOTTOM OF CABINET (SEE PLAN VIEW 1 -3) (rw) FLOOR ACCE55 ® SIDE ELEVATION FRONT ELEVATION (CUSTOMER SIDE) FRONT ELEVATION (EMPLOYEE SIDE) © © ()GASH WRAP ELEVATIONS ,•_,. -0. 2' 2' / N Seattle South Center SPACE 316 Seattle, Washington L -1 • ' 1 I 1 I 1 1 I \ ELEVATION (EMPLOYEE SIDE) NOTE: AT NALL INSTALLATION THE BASE WILL CONTINUE TO THE WALL. ALSO THE COUNTER L 1 — RUBBER BASE APPLIED AFTER INSTALATION OF ELECTRICAL AND GASHWRAP 15 LEVELED AND SECURED TOP WILL BE FLUSH AT THE NALL SIDE. TO FLOOR WITH CONSTRUCTION ADHESIVE. (TYP) N AT WALL SIDE ELEVATION r� ELEVATION (CUSTOMER OR HALL SIDE) ® INSTALLATION v O BAGKRAP ELEVATIONS 20 W REVIEWED FOR CODE COMPLIANCE APPROVED 1. =1'-o. WALL (WHERE USED) JUN 10 2011 TNO COMPARTMENT m AND DATA POWER POLE LOCATION. ON JOBSITE • L HOLE GUT ® REVISIONS DATE 'W C�� C� T w-� 20 Ab 2 1 VI`w`I� BUILDING DIVISION- Bid Set 5-2 -11 Permit. Set 05-02 -11. 0 # ■ ( , � REV. Set 0601 -11 y 4 RECEIVE�,�pp. CITY OF TUrcrin Const. Set 00-00 -00 ■ SCALE: }• = 1' -0" L -2 - zo L -2 - �o JUN 01 2011 DATE: JUNE 1, 2011 "6 BACKNRAP PLAN (AT FREE FLOATING INSTALLATION) © BACKWRAP PLAN (AT NALL LOCATION) CASHWRAP PLAN © 0 PERMIT CENTER 1 GASHWRAP PLAN KEY MATERIAL BY MANUFACTURER DESCRIPTION !J r=1' -0' L -1 LAMINATE SURFACE G.C. PIONITE PLASTIC LAMINATE SURFACING. COLOR = HP359'THUNDERSTORM ". GRAIN TO RUN HORIZONTAL. Ab • 2 L -2 LAMINATE SURFACE G.C. PIONITE PLASTIC LAMINATE SURFACING. COLOR = "TAUPE ". L-3 LAMINATE EDGE BANDING G.C. NA �s" EDGE BANDING. COLOR = "ALUMINUM ". 2-8 "A SHELF FOR AMPLIFIER �' 24' SHELF STANDARDS I af- D' -t ID" X1B'X3I4 "PLYWOOD — PHONEBOARD i OUTLET FLOOR LEVEL DATA PANEL 2 -- — OEXISTINO TO REMAIN —O PROVIDE POWER TO — ENTRY 40511645LE UNDER DISPLAY PARDON PLATFORM POWER PLAN 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESONSIBLE FOR THE COORDINATION OF THS WORK T IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE ALL SUBCONTRATORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY CIRCUITING SHALL BE THRILWIRING' WHERE AND WHENEVER POSSIBLE. 3. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 4. ALL RECEPTACLE CIRCUITS UP TO 107-0' SHALL UTILIZE 012 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101'-0' TO 150-0' IN LENGTH SHALL UTILIZE 010 CONDUCTORS MINIMUM. All RECEPTACLE CIRCUITS 15O0' TO 250-0' IN LENGTH SHALL UTILIZE 08 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251•-0' SHALL UTILIZE 06 CONDUCTORS MINIMUM. 5. PLACEMENT OF ALL RECEPTACLES IN THE 'SALES' AREA SHAT BE INTENTIONAL (.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT CORNERS AND AT 18• AF F UNLESS OTHERWISE NOTED). IF THE RECEPTACLE IS NOT SHOWN IN DESIREABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENNANTS PROJECT MANAGER PRIOR TO ROUGH W. 8. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 7. WHERE DRYWALL CEIUNGS ARE USED IN THE 'SALES' AREA THE ELECTRICAL CONTRACTOR SHALL ARRANGECIRCURS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CENNGS SHALL BE UMITE TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH DOWN EAST BASICS PROJECT MANAGER PRIOR TO ROUGH-IN TO AVOID ANY CONR)CTS. JUNCTION BOXES ABOVE LAY -15 CEILINGS ARE ACCEPTABLE. 8. EQUIPMENT LABELED 'GE' SHALL BE FURNISHED BY DOWN EAST BASICS AND INSTALLED BY THE ELECTRICAL CONTRACTOR REFER TO CODED NOTES, ELECTRICAL RESPONSIBILITY SCHEDULE, PANEL SCHEDULE AND POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION. SEE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. 9. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORDS REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRIAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COSTS AS A SEPARATE UNE REM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR THE TIE-IN REQUIREMENTS TO A LANDLORDS FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE REM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. 10. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT SWITCH IN LANDLORD'S SWTCHGEAR WITH DEMISED PREMISES SPACE NUMBER IF NOT ALREADY EXISTING. 11. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK. 12. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD, WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECENED PRIOR TO ANY WORK BEING PERFORMED. A.U. ROOF PENETRATIONS TO BE BY LANDLORDS CONTRACTOR AT TENANTS ELECTRICAL CONTRACTORS EXPENSE. 13. RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED VERTICALLY AT IS ASP. UNLESS NOTED OTHERWISE. 14. ALL RECEPTACLES, SWITCHES AND COVERPLATES SHALL BE WHITE IN COLOR 15. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED FLOORS(AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND PATCH FLOOR TO MATCH DUSTING. COORDINATE ALL WORK WITH LANDLORD PRIOR TO STARTING WORK. 16. SPEAKERS AND COAXIAL CABLES WILL BE FURNISHED BY DOWN EAST BASICS AND WILL BE DELNERED TO THE JOB SITE DURING THE CONSTRUCTION PERIOD. ELECTRICAL CONTRACTOR IS TO INSTALL ALL EQUIPMENT AS DESCRIBED IN INSTALLATION INSTRUCTIONS INCLUDED IN THE PROJECT MANUAL. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL ALL NECESSARY CONDUITS, WIRING, JUNCTION BOXES, ETC. AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM. VERIFY PROPER OPERATION OF ALL EQUIPMENT PRIOR TO TURNING SYSTEM OVER TO DOWN EAST BASICS. 17. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL 7YPEWRJTTEN PANEL DIRECTORIES IN ALL PANELBOARDS. 18. ALL RECEPTCLES TO BE MOUNTED VERTICALLY NOT HOR2ONTALLY. SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED TOGGLE SWITCH, DUPLEX RECEPTACLE, 3 WIRE GRD. TYP. QUADRAPLEX RECEPTACLE TELEPHONE OUTLET DATA 0511E7 FIRE ALARM AUDIO / VISUAL SIGNAL DEVICE ALL SYMBOLS DO NOT NECESSARILY APPLY 48' 18' 18' 18' 18' 96' O RECEPTACLES, DATA AND TELEPHONE OUTLETS MOUNTED ON WALL OF CASHIVRAP AT FLOOR LEVEL COORDINATE EXACT PLACEMENT OF DEVICES AND WIRE ROUTING W CASHWRAP WITH MILLWORK DRAWINGS. 02 EXISTING TELEPHONE BOARD TO REMAIN. PROVIDE SHELF AND POWER AS NECESSARY FOR MUSIC AMP AND ROUTER. • EXISTING PANEL IA'. 120 1 2081/, TO REMAIN O PROVIDE DEDICATED 120 VOLT, 20 AMP CIRCUIT AS SHOWN. 14' AFF. OWNER PROVIDED SECURITY CAMERA SYSTEM, PROVIDED AND INSTALLED BY OWNER. 05 DEDICATED CIRCUIT FOR REFRIGERATOR AND MICROWAVE. 18' A.F.F. 08 DEDICATED CIRCUIT FOR SECURITY SENSOR AT FRONT EMT. SEE REQUIREMENTS SHEET A0.1. • RECEPTACLES AND COVER PLATES DESIGNATED 'SP' SHALL BE MOUNTED ON THE UNDERSIDE OF THE STOREFRONT SOFFIT WITH THE P SIDE PARALLEL TO THE STOREFRONT GLASS. • TWO 1' RIGID CONDUITS UNDERFLOOR FROM CASHWRAP TO NEARBY WALL, UP WALL 70 AVOVE CEIJNG AND 70 ELECTRIC PANEL OR TELEPHONE TERMINAL BOARD AS LABELED. STUB CONDUITS UP 0 ABOVE FINISHED FLOOR AT CASHWRAP. • DUPLEX RECEPTACLE W WALL FOR DATA AND SOUND EQUIPMENT SEE DETAIL 10 EASING SIGN TIMER MOUNTED ON WALL TO REMAIN r SEPARATE PERMIT AND APPROVAL REQUIRED arroRu► JUN 01 2011 PERMIT CENTER FLOOR GENERAL NOTES ELECTRICAL SYMBOL LEGEND FLOOR KEYNOTES CD CD c4_1•-t4 0 Seattle South Center REVISIONS DATE Bid Set 5-2 -11 Permit. Set 05 -02 -11 REV. Set 06 -01 -11 Const. Set 00-00 -00 SCALE: }' = 1• -0" DATE: JUNE 1, 2011 POYVER PLAN E1.0 CI) .� I o - -- — - - -- — - — o o I T. j �5q I - fi= -- - �_ ° �� ° — o °; «° �� ■ � �.�A ■ . .. d o II di 11 • 1 1 CI 1 ° . j ° —c�; , - a--- 6 -- - - -� -- s - - -a - -- --- a - - -�- a - - -a -- 6 - - -� - -a I - - -a - - - -a- I VESTIBULE CEILING PLAN Seattle South Center SPACE 316 Seattle, Washington NOTE SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. VERIFY ALL CONDITIONS IN FIELD RIOR TO BIDS. LIGHTING PLAN }'.l o 1 1. THE CONTRACTOR FOR THIS WORK 15 REQUIRED TO READ THE 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS SPEGFlCATIONS AND RENEW DRAWINGS OF ALL DMSIONS OF WORN AS REQUIRED FORA FULLY COMPLETE AND OERABLE SYSTEM. AND IS RESONSIBLE FOR THE COORDINATION OF TANS WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE ALL SUBCONTRATORS B. WHERE DRYWALL CEIUNGS ME USED IN THE SALES AREA, THE WUH ACOMPLETE SET OF BID DOCUMENTS. ELECTRICAL CONTRACTOR SHALL ARRANGECIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE UNITE TO GRCU LNG SHALL BE 'THRU- WIRING' WHERE AND WHENEVER POSSIBLE. LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN MR GRILLES OR ACCESS PANELS AS LOCATED ON PUNS. FIELD 3. SEE ARCHITECTURAL REFLECTED CEILING PUN FOR EXACT LOCATION COORDINATE WITH DOWN EAST BASICS PROJECT MANAGER PRIOR TO AND QUANTITY OF LIGHTING FIXTURES. ROUGH-IN TO AVOID MY CONFLICTS. JUNCTION BOXES ABOVE LAY4N CEILINGS ARE ACCEPTABLE. 4. ELECTRICAL CONTRACTORS BID SHALL INCLUDE THE INSTALU7gN OF ALL LIGHT FIXTURES AN ASSOCIATED LIMPS 9. EXIT /EMERGENCY LIGHTS AT STOREFRONT ME TO BE CEILING FURNISHED BY DOWN EAST. ELECTRICAL CONTRACTOR IS RESPONSIBLE MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.O.). EXIT 1 TO ENSURETHE ADJUSTMILTTY OF ALL DIRECTIONAL FIXTURES AFTER EMERGENCY LIGHTS AT DOOR TO "NON - SALES' SHALL BE CENTERED ON INSTALLATION AND AIM THEM. UGHT FIXTURE SPECIFICATIONS MAY WALL AVOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING VARY. IF CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR IS TO HEIGHT WITH DOWN EASTS CONSTRUCTION MANAGER PRIOR TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH DOWN EASTS ROUGH -IN LIGHTING SUPPUER 5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED MD CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY CLOSELY COORDINATE INSTALLATION WITH DOWN EASTS CONSTRUCTION TI BACK UP (OWN EASTS CONSTRUCTION MANAGER 5 ALL LIGHTING CIRCUITS UP TO100-0' SHALL UTILIZE %12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101'-0' TO 150-0' W LENGTH SHALL UTILIZE %tO CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 150-0' TO 25047 W LENGTH SHALL UTILIZE 88 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251'-0' SMALL UTILIZE 06 CONDUCTORS MINIMUM. 1 INSTALL HALO OR HALO COMPATIBLE TRACK OWNER TO PROVIDE HEADS AND BULBS. INSTALL LIGHTS AT 3b" O.C. O SOUND AND SECURITY SYSTEM BY OWNER O REUSE EXISTING 2X2 LIGHTING, ADD ADDITIONAL 2X2 LIGHTING TO MATCH EXISTING. O4 REUSE EXISTING 5' FLOURESCENT LIGHTS, INSTALL AT 12'-O AF.F. /����� V` /� }� �r a�P ���o `l r R Q/ I qE I`l�Ji /V� ME 4 SYMBOL MANX DESCRIPTION MANUFACTURER & MODEL NUMBER HEIGHT LAMP DESCRIPTION WATTAGE ---- -- F1 TRACK LIGHT HEAD WAC JTK-764 (JUNO COMPATIBLE) OR WAC JTK -764 (HALO COMPATIBLE) r 75 WAIT MA) O PENDANT UGHT M TECNICA POWER CORD, 15 FEET WHfTE. 6O WATT OR SMATTER LAMP, 120 V, TYPE A-19 M TAMP. CASHWRM LOCATION) 0 //// WALL SCONCE �1� RECESSED CAN IKEA LIGMING'KRYSSBO' WALL LAMP 17" (VERIFY H Halogen bulb G4 IOW REVISIONS DATE Bid Set 5-2 -11 Permit. Set 05-02 -11 HANG MOUNTED 2-LIGHT 4' STRIP, FLOURESCENT 120V TB 32 WATT BULB REV. Set 06-01 -11 ■ ---- -- 252 FLUORESCENT LIGHT Const. Set 00-00-00 21.4' FLUORESCENT LIGHT SURFACE MOUNTED 2-LIGHT 4' STRIP, FLOURE5LEM 120/ TD 32 WATT BULB TB 32 WATT BULB —. - SCALE: }" = 1' -0" DATE: JUNE 1, 2011 HANGING 4�IGHT B' STRIP, I FLDURESLENT 120V TB 32 WATT BOLO 1 LIGHTING ,I 210' FLUORESCENT LIGHT RECEIV L . RESTROOM VENT OF art O � PLAN d..®.b PENDANT MOUNTED INTERNALLYIUAIMINATED EXIT SIGN WITH 2 HEADED EMERGENCY LIGHT AND 1 I HOUR BATTERY BACKUP. JUN 01 2 011 E 2 • 0 WALL MOUNTED INTERNALLY A140 1(HOU94 BATTERY TIER ROTH Z HEADED EMERGENCY LIGHT AND 11 HOUR OATTERY BACKUP. PERMIT CENTER LIGHTING GENERAL NOTES CONSTRUCTION KEYNOTES LIGHTING FIXTURE SCHEDULE