Loading...
HomeMy WebLinkAboutPermit D11-139 - TUKWILA BUILDING - REROOFTUKWILA BUILDING 14404 51 AV S D11 -139 Parcel No.: Address: Suite No: Project Name: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov 7999600160 14404 51 AV S TUKW TUKWILA BUILDING DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D11 -139 05/20/2011 11/16/2011 Owner: Name: TSANG RICK Address: 3215 HUNTS POINT RD , HUNTS POINT WA 98004 Contact Person: Name: RICK TSANG Address: 3215 HUNTS PT RD , HUNTS POINT WA 98004 Contractor: Name: GOOD SHEPERD CONSTRUCTION Address: 275 PATRICK RD , EPHRATA WA 98823 Contractor License No: GOODSSC910PZ Phone: 206 - 234 -9655 Phone: 509 - 280 -6838 Expiration Date: 10/09/2011 DESCRIPTION OF WORK: REMOVE EXISTING TORCH DOWN ROOF MATERIALS & UNDERLAYMENT. RECOVER WITH NEW UNDERLAYMENT AND 1500 SQ FT POLYFLEX AND APPLY SMOOTH TORCH DOWN ROOFING MATERIAL Value of Construction: $3,200.00 Type of Fire Protection: AFA Type of Construction: V -B Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $332.90 2009 0008 * *continued on next page ** doc: IBC -7/10 D11 -139 Printed: 05 -20 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: LajiG Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: /?j C% lSfj N el Date: s This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11-139 Printed: 05 -20 -2011 ' 03-21- 11 11:06 FROM- elicceork:; /dcd CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us 2064313665 • T -018 P'004/012 F -658 Building Permit No. bA 3� Mechanical Permit No. Plutnbing/Gas Permit No. Public': Works Permit No. Project No. (Fur office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** SITE LOCATION WINE. Kin Co Assessor's Fax N01q 19 60 - 0160 — Site Address: 44 3 W 1 AvE, 3 Tv bewtLY\ y.1% Q L.lt1 T Tenant Name: Property Owners Name: �v Mailing Address: 3 2 1 rj \-\,•.■• S fl I•-0 • — }��h' S Ip'i `� Stntc zip Suitc Number:_ New Tenant: Floor: 0 Yes O _No Giry CONTACT PERSON — who do we contact when your permit is ready to he issued Name: iz 1 e,� PC 1`1 Mailing Address:3a` S )..\\ •k`'• 1T- `t'� 1 �\A E -Mail Address: �F -�'S cJ �l1MC�, t GENERAL CONTRACTOR INFORMATION — Day Telephone: dry Fax Number: virt- State Zip (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 3)) Company Name: G(364 51,4.p1,9„.41, Mailing Address: 21 S P%9� t1 4c. 4.7 ., Lyj�j k�� #1.A _3.8' 3 1t state Zip ,Q j Contact Person: . �w►��l �. � NY6 Day Telephone: s-01--210- 6 a 3 t% E -Mail Address: LA- '` t rim 01 bit 2 63 IAH 40 • C% , S Fax Number: 2 - 3 4- k Contractor Registration Number: 6 O DI S,c C. lit. O p e Expiration Date: (tl l 4 1 - a ARCHITECT OF RECORD — All plans must he stamped by Architect of Record Company Name! Mailing Address: Contact Person: E -Mail Address: (.1(Y Day Tcicphonc:___ Fax Number: ENGINEER OF RECORD —All plans must be stamped by Engineer of Record S(aUe Zip Company Name; Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address; Pax Number HAAppheaiioosTom(:- Apphill Ong U.. LLne4010 Appiirerion 67- ?010 - ?[thud Apps; iuo. doe Rensnd: 7 -2010 bh Page 1 of 6 . 03 -21 -' 11 11: 07 FFiO[ °]- 11icmorks /cici_i IBUILDING PERMIT INFORMATION — 2%- 431 -3670 '11r;9;;1:;t;t'.; • T-012 FW35/0112 F-658 Valuation of Project (contractor's bid price): $ 3 2 Clp • Existing Building Valuation: $ I +'' S 6-0 Scope of Workk (please provide detailed information): (�iLtn� vVg,s �j(; Zvi -ko /� doti1 t'�,t �a 04- - INN atflA.A p oty -� �i! S .,r.o o Y� i-a „,. glow w J, a yv. �c�,; r.;X5 • � Will there be new rack Storage? ❑ Yes a, If yes, a separate permit and plan submittal will be required. Provide All Building Areas m Square Footage Below PLANNING DIVISION: IA Single family building footprint (area of the foundation of all structures, plus any decks ovcr 18 inches and overhangs greater than 18 inches *For an Accessory dwelling, provide the following: Lbt Arca (sq ft): Floor area of principal dwelling : Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one attic dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap! Will there be a change in use? ❑ 'Yes 121...... Nu If "yes ', explain: FIRE PROTECTION /HAZARDOUS MAl'1EItIALS: ❑ ... ... Sprinklers 12........ Automatic Fir c Alarm 1.7. None Q Other (specify) Will there be storage or use of flammable, combustible of hazardous materials in the building? ❑,,,,,,.Yes ��,,// If ':yes', attach list ofrnaterials and Storage locations" in a separate 8-1/2" .r 11 " paper including u&- • •• No I F g yuuntit+as tint! A�laterial SirJery Uuta Slraets. SEPTIC SYSTEM IsItt ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 114.1Appliomion:VPonn,- AppliwGOns On L. 2010 Applicationr17 -2010. Puma Applica,ion.doc Revised: 7-2010 iM Page 2 oft; Existing -..� Interior Remodel Addition to Existing Structure -- New NQ - "-' type of Construction per IBC - Type of Occupancy per IBC tD1Floor (jOV ♦ 2nd Floor ___Ni --' -" 3`0 Floor -- --- – - -- Floors thru Basement L Accessory Structure* — — Attached Garage Detached Garage Attached Carport — _ Detached Carport – – Covered Deck Uncovered Deck PLANNING DIVISION: IA Single family building footprint (area of the foundation of all structures, plus any decks ovcr 18 inches and overhangs greater than 18 inches *For an Accessory dwelling, provide the following: Lbt Arca (sq ft): Floor area of principal dwelling : Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one attic dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap! Will there be a change in use? ❑ 'Yes 121...... Nu If "yes ', explain: FIRE PROTECTION /HAZARDOUS MAl'1EItIALS: ❑ ... ... Sprinklers 12........ Automatic Fir c Alarm 1.7. None Q Other (specify) Will there be storage or use of flammable, combustible of hazardous materials in the building? ❑,,,,,,.Yes ��,,// If ':yes', attach list ofrnaterials and Storage locations" in a separate 8-1/2" .r 11 " paper including u&- • •• No I F g yuuntit+as tint! A�laterial SirJery Uuta Slraets. SEPTIC SYSTEM IsItt ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. 114.1Appliomion:VPonn,- AppliwGOns On L. 2010 Applicationr17 -2010. Puma Applica,ion.doc Revised: 7-2010 iM Page 2 oft; 03-21-'11 11:07 FAOM- 1 nicworks /tlr-rl 2:064 :313665 • T -0:18 P006/012 F -658 IPERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should he entered by the applicant to possible revision by the Permit Center to comply with Cunent fee schedules. This figure will be reviewed and is subject Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105 -3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding ISO days. The extension shall be requested in writing and justifiable cause demonstrated, Section 103.4.3 Tinian-in Plumbing Code (Current edition) 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE' UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT_ BUILDING OWNER O.It AUTI IZED A Signature: Date: 11 Pl q Print Name: f i?f •�C / S� /� G) Pay 'Telephone! _02� -2 Z . 9 tT Mailing Address Date Application Accepted: dtAn s yr o• 1k4? f % fJi 9gad Ststo Late Application Expires-. klApplicanonsVomts- ApplIcainn5 On LL,tQ20 10 AppliemionsV,. )IO -1 n,,il Avnl it nt:p■ dn; kovi.d 7 -2410 W Staff Initials: Zip Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.Tukwila WA.e,ov RECEIPT ParcelNo.: 7999600160 Permit Number: D11 -139 Address: 14404 51 AV S TUKW Status: PENDING Suite No: Applied Date: 05/20/2011 Applicant: TUKWILA BUILDING Issue Date: Receipt No.: R11 -01022 Initials: User ID: Payee: WER 1655 Payment Amount: $332.90 Payment Date: 05/20/2011 09:26 AM Balance: $0.00 RICK TSANG TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5128 332.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 328.40 640.237.114 4.50 Total: $332.90 doc: Receiot -06 Printed: 05 -20 -2011 f s INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 4/ %3qPERMIT NO. (206)431 -3670 Project; Type of Inspection: Address/At Date Called Special Instructions: Date Wanted: .... Li/ 4 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (4, - Inspecto r• 1 if ❑ $60.00 R INSPECTION F REQUIRED. Prior to inspection, fee must be paidat 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No.: Date: 4 2, INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain;a copy with permit PERMIT NO. td, (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ii-we4211 , 8147.e. 41'"Idtri nspector: gtz Date: ..s......„3/7/1/ ri $60.00 R INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: J Type of Inspection: ProjectL— 7 'Ad dres : >5^ Date Called: Special Instructions: 10;" Wanted: �/ p.m. Requester: 1 /I •F_ � cf Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ii-we4211 , 8147.e. 41'"Idtri nspector: gtz Date: ..s......„3/7/1/ ri $60.00 R INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPEC7ION NO. CITY OF TUKWILA BUILDING DIVISION �-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit • Project: % ® . [. li �lsi Pik Type of Inspection: / ,r` �i,/.�C Addr"eeess�61�,�/ Au ,c /Date Called: Special Instruc ions: /0 :00 Date Wanted: 2/ .. Requester. / ' !i4 /5,4at�j Phone No: l ElApproved per applicable codes. Ei Corrections required prior to approval. COMMENTS: 7 J-2, 4,d nspector: Date Z)-1( ri $60.0 EINSPEC ON F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Parcel Viewer • La King County Parcel Viewer One Parcel Found: Parcel Number Address .7999600160 14403 51ST AVE S, Search Menu IUtp:// www5.kingcounty.wv /parcelviewer /viewer /kingcounly /viewer Intro I Help { Print Standard Mode Enhanced Mode ":43€1-1 Current Tool: Zoom In 1 Parcels Found: Record 1 Parcel Number Site Address Zip code Taxpayer 7999600160 14403 51ST AVE S 98168 TSANG RICK Get Property Report Get Districts Report Check DDES Permits FI ECOPY Permit No, 11- 1/1 PIctn review approval is subject to errors and omissions. kproval of construction documents does not authorize thf.v1olation of any adopted code or ordinance. Receipt c' approved Field Copy and condtions is acknowledged: By Date: City Of Ttbkwlla BUILDING DIVISION REVISIONS No changes shall be de amam to the scope of work without prior approval of ;3k '.r;'a Building Division. t7i1 l ,uire a new ratan cttbmi$ -I I of I Tukwila a MOWED CITY OF TUKw MAY.. 2 Q 2011 PERMIT CENTER Current REVIEWED FOR CODE COMPLIANCE APPROVED MAY 202011 VL 'a City of Tukwl 6UILDINP fnneinto l39 C /lRr-)nl 1 c. 1 n Iron AERIAL PHOTO REMEWEri FO CODE COMPLIAN APPROVE MAY 2t) 201 , City of Tukwila BUILDINP niuminki ' ' wr hVirt' 171 •:CffYOFTu MAY 2 2011 VIKIase...ar+r Mit of Awes M, ems 1 11 1 1 SEATTLE FIVE ACRE ASSESSORS MAP 119,9 AC9 NI L 1.M N'!: NW 23 -23 -04 f.ec 09 ,099 G = GAR 14403 5V' Ave S Vacation Pile No. 9 -1031 OMP^wr ilionnomm Ems remopool6 g Grin rimui 'IRS tn LEN E Page 7 CODE PL' el RECEIVED OFTUKWILA 0, 2011 IADCPA 4A.STFR CONM, LADCPA Condo n MAY 202011 City of Tukwila BUILDIN( nfvicinto Parcel No. 11n-assigned To: Rick Tsang Page 1 of 1 2011 -05 -06 04:11:03 (GMT) Construction Contract 15093558402 From: jimmy evan; This construction contract is made effective as of May 5, 2011 by and between Rick Tsang and Good Shepherd Construction. Contractor agrees to provide Construction services to Rick Tsang and he agrees to obtain such services from Contractor. THEREFORE, in consideration of the mutual promises set forth below, the parties agree as follows: DESCRIPTION OF SERVICES Good Shepherd Construction will provideto Rick Tsang the following services at 0404' em s 4494 51St Ave. South, Tukwila, WA 98188: e\ y RQ,K.vQ. >' Hau.t 0.14147 olectkIh (n4 9.144.... %to. Install MO& quare feet of torch down roof membrane along with new eave metal New flashing, and new sheeting if needed pj vt�o Z 1ZS o� v` � �a� L,v+i'itv'o�lCc� L ,�,,,�„� yyw, e v,� . O PAYMENT - shall be made to Good Shepherd Construction for completion of the job of this contract in the amount of ....$3,200.00 for labor and for materials. Good Shepherd construction •4, Jimmy Evans (509)280 -6838 NEGSVED C1TV MAY.2 Q 20111 PERMIT CENTER Contractorname Jimmy Evans -- owner Owner signature � /1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 202U11 City of Tukwila BUILDIN( nnn��r1F� 1 SmarrZone Communications Center http: / /sz0032.ev.mail.comcast. net / zimbra /h/printmessage ?idjS00320... • • • BOTHELL SENIOR HIGH SCHOOL 9130 Ne 180th St, Bothell, WA 98011 Telephone District Name Situs State Institution Name Situs Street Situs Zip Enrollment -Zoned Decimal Lowest Grade Highest Grade School Type Kindergarten School Enrollment Advanced Placement Textbook Expenditure/Student Supply Expenditure/Student Total Expenditure/Student Poverty Level SECONDARY ACADEMY FOR SUCCESS 18603 Bothell Way Ne, Bothell, WA 98011 Telephone District Name Situs State Institution Name Situs Street Situs Zip Enrollment -Zoned Decimal Lowest Grade Highest Grade., School Type Kindergarten School Enrollment Advanced Placement Textbook Expenditure/Student Supply Expenditure/Student Total Expenditure/Student Poverty Level (425) 408 -7000 NORTHSHORE SCHOOL DISTRICT 417 WA BOTHELL SENIOR HIGH SCHOOL 9130 NE 180TH ST 98011 1630 10th 12th Senior High No 1,000 -2,499 Yes $7,800.00 - $8,199.99 0% - 5.9% (425) 408 -6600 NORTHSHORE SCHOOL DISTRICT 417 WA SECONDARY ACADEMY FOR SUCCESS 18603 BOTHELL WAY NE 98011 143 7th 12th Senior High No 100 -199 Unknown $7,800.00 - $8,199.99 0% - 5.9% ' Courtesy of Robert Carroll NWMLS The data within this report is compiled by CoreLogic from public and private sources. If desired, the accuracy of the data contained herein can be independently verified by the recipient of this report with the applicable county or municipality. RealistReport.html 100 KB 8 of 3/19/2011 8:02 PM POINFLEX® PRODUCT DESCRIPTION Polyflex membranes are premium, polyester reinforced APP modified bitumen roofing products specially designed for heat-welded applications. Constructed with premium Ataclic Polypropylene resins, and incorporating superior polyester reinforcing, Polyflex provides an exceptionally durable, roofing product which is aasy to Install and will provide long -term weathering performance. With o smooth surface and either o polyolefin or sand backing, Palyflex exceeds all minimum ASTfA ;iandords for tensile strength, puncture resistance and flexibility. Polyflex membranes con also used as flashing membranes in all opplicabie specifications, in accordance with recommended installation practices. USES • Heat - welded or cold - applied base or cop sheet • Applied directly over on acceptable substrate of as part of a multr'ply system • New roofing, re roofing, re -cover and for flashing details FEATURES AND BENEFITS • Exceptional weathering characteristics • Puncture and tear resistant • Low -temp flexibility, exceptional tensile strength and elongation properties TECHNICAL DESCRIPTION TEST METHOD • r. PROPERTY ASTM P5147 ASTM D5147 Thickness, typical, min ft-n.118) Peak Load C7 23 + / -2C (73 44-/- 3.6F), MD and XPv1D, min, kN /rn {(bfi in,J ASTM 05147 ASTM D5147 Eton @ation t 23 + / -2C- (73 aid WO, rain ( %i Tsui Strength c§r 23 + /•2C (73.4- 1/- 3.6F ), min, 1%J (Ibt) ASTM 6222 low Temperaiure Flexibiky, max, C IFl SURSOM CITYOFTU ► , MAY .202011; PERMIT CENTER O4,r2010 SO/ Ter .9JVd 4.0(1-`, (:I 8.13 (50) 23 11170) 0 132; REVIOWED FOR CODE COIMPLIA CE APPROVED MAY 2Olull City of Tukwila BUILDIN( nnncilnwW PROD r_oyeroge IApproxi.,...,.....- 100 sq It :'v�lghi 85 (bs Roll Sze 32'10"x 39 4,70' II Om is I rri) 23 APPLICABLE STANDARDS • ASTM D 6222 Type I • Mien Dada Code Cornplionce • Faclory Mutual Approved • tit Classlllrsd for use In ck7ss A, 8 or C roois, as Ilstud in tilt iciest UL "Roofiricj Materials and Systems Direciory • ICC•ES# 2018 • TDI PRODUCT WARRANTY lJn cos othrrvNi:r, 111(.01p:irati -d irtr<;, ,;,r pod of supplempntpl monuiar;111rer's warranty warrants i!s produd(s) fir o priod of 12 .,cars aaainsl manufacturing dafects in il; praduc:t Ihul dac.cily rosulls rn kako8e. Vyauany to +li•a` ?u rs an onnuolly dtcllri4i9 pre -tart„ d waur1nly. w1,TrxpHnu[rr rG ldnr14LtL1 :.i 5 r[rbuf.ein1i sYrrr : ; +s POLYGLASS a kit* kneiegt 1..808 - 222 -99$2 w'ww.lwlyglass.com Ell :lir Zto7 /hl.; "7Gt POLYF LEX® APPLICATION INSTRUCTIONS Poiyflex is intended to be used cis a base sheet ar inter ply in new or re-root applications. f olyflex may be applied directly to non-combustible substrates_ Polytlex requires the installation of a compatible granulated cop sheet to complete the roofing sysieni. • Apply over clean, dry, dust and debris free substrates. Prune concrete decks piicr to application with PG 100 Asphalt Primer. • When re- roofing, remove all prior roofing materials down to c clean debris -free substrate and properly close -off all obondcned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devil :;.s. • Wood decks shall have olI points blocked and properly supportr;cf • Ensure the fire rating of the assembly over any combustible substrote. • Ensure the installation of Polytlex does not prevent the ventilation of existing construction • Do not apply over shingles or any granulated surface. • While installing Polytlex: 1 Stott at the low point of the roof. 2. Unroll the material and allow to relo:c in he sun for at least 15 minutes. 3 Install with traditional torch roofing techniques ensuring pinper heating of the roofing material as not to expose the reinforce -meni, 4. Do not heat the substrcte. 5. Position successive rolls providing a minimum 6" end lap and 3' side lop. Asphalt bleed out shall be 1 /4" to 3/8" on all seams. 6. Lops shall be rolled with a 6 "-wide roller immediately otter haat welding. • Details and flashing may be installed using Polyflex with torch opplied techniques, Do not use cold adhesives or hot asphalt. Check project details for proper installation requirements. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Hoven, FL memo ow OF MAY 20 2011t HERMIT CENTER ALL I»A >U IIINGG 444T,4/.040M11) (7� UCT105 GD 01,51 Y$UCI5R Al AI� WUUU YUS U'SUL. wUYyUYATYF1nG AHU 116�IfWil 011y/WfCY RCSI0NSIRtC.QI 502 552 OVIIp (ROUNCII UNGO COMOISIDYS 0!(050 (IS 0554 COMISOL W YnpUl r4u4 :011[e. VOlW.1w55 US^ Y5C 1:54NG. Rt ne10 REVIOWED FOR CODE COMPLIANCE A=ROVED MAY 202011 City of Tukwila BUILDIN( nntisinni WUTERP11001'r11G UAI 01(1,11.1; clip ti1SCLd "l1Nc Sl'riTE1d6 .OLYGLASS E1 Adoksitzegeat 1.500 -222 -9782 W'wW.poiyglass.coni 60 :0T .1Tn„ /FYT Qr APP SMOOTH Modified Asphalt Roofing Membrane Mixture APP Smooth (MOdibone, Polybond, Polyttex. Polytlex HP, Uutlex, Polyglass Bane) Polygla &s USA, Inc. 150 Lyon Drive - Fernley, NV 80402 775.575- (3007 www.polygiaes.com 800.424 -9300 Cherntrec APPO1 December 1, 2001 Health 1, Reactivity 1. Flammability 0 0- (east, 1- slight, 2-moderate, 3 -high, 4- extrema Petrolef 1 Asphalt Calcium Carbonate Polyethylene Polypropylene Ethylene Propylene Copolymer Non-woven Polyestur Cont Filament glass fiber crystatliirie silica, QuEtth Asphalt Limestone Polyethylene Polypropylene Copolymer Polyester mat Fiberglass mat Sand 8052 42 4 53 -5 - 61.0 1.7317ES3 7.1 -20.3 900',2 88 4 0.2.5 5003 07 0 4.5 -7,9 9010 79 1 5.6 - 22.4 None, assignod 2.0 - 3.7 65997 17 3 0 -1.0 /4808607 5.8 -69 5 mg1m3 PEL 5 mg /m3 PEL (Respirable) 15 mg /m3 PEL (Total) S mg /m3 PEL (Respirable) 15 n' /m3 PEL (Total) Not Established 5 mg /m3 PEL (Respirable) 15 rng/m3 PEL (Total) Not establtsriad 5 mg/m3 PEL (Respirable) 15 mg /m3 PEL (Total) 0,1 mg /rn3 PEL (Respirable R NCE A DROVE® MAY 2u 2011 f Appearance, 13oiting point Evaporation Rate Flesh Point Melting Point Odor Ph (undiluted product) Saturation in air Solids Content Specific gravity Vapor Density Vapor Pressure Viscosity VOC Volatility Water solubility tP . L 'G LASS werdrixoont.c wxYhW,B A5O rxdowr.ue drdt.utd SO /CO .eiUd N/A deg F N/A deg F deg F N/A N/A O,y NIA g /cc Air -1 NJA r; P y /hter uo >650 N/A >430 >290 Mild aepha 1/potroteunl odor N/A N/A N/A 1,02- 1.30 N/A N/A N/A N/A 0.1 0.1 CRY OF TUt±(wtLA ,MAY. 2 g 2011 POLYGLASS USA, inc.: Carponate Office & Manufacturing Facility Fornley, Nevaax 89408 - Phone (775) 575.6007 Fax (775) 575 -2314 • roll Free (800) 222 -9702 - Manufacturing Facilities Hazleton, Pennsylvania 18202 - Phone (570) 384 -1230 Fax (570)3E43202 • Toll Free (000) 694 -4563 - Winter Haver,. Florida 33880 - Phone (863) 297,5985 - Fax (B63)297.5858 - Toll Free (861ii) 002.8017 www.polygla3S.co n - e-n tail :euaromerservicuttpolyplass.corn 9L? 22F:B1' 1' CO :O T [(7...F,Tic,) nni Flash point Lower ExpioS VU Upper Explosive 43O deg F (ASTM D92) Limit Undetormined Limit Undetermined Tab r„ , It�Ct t ti 91.A i tv. .16.4,2; ,C .,y..7�::..UO A.- , .,m .. - 1C71 Wear self contained breathing apparatus Insufficient evidence at cancer induced by exposure to asphalt fumes. The international Agency for Research on Cancer (IARC) considered Crystalline Silica as a human carcinogen. Prolonged exposure to Crystalline Silica containing dust can lead to Silicosis. Continuous filament glass fibers are not classified as Garclnegens. However no significant health hazards art; likely to occur due to the product forte and nature of use. Uppor respiratory system Inhalation Skin Contact Skin absorption Headache, nausea, coughing, irritation of the upper respiratory 3y. Burns caused by contact with hot rn Not applicable eft's/OF TUKWILA Ingestion Not intended 10 be ingested MAY 0 2011 ! Eye Contact Irritation/redness may occur 1 APPROVED MAY 2u2O11 Do not induce vomiting. Treat symptomatically. :.:Yr.?y .:LL "i �r' *�'•r''tw, i'.1� '%f r.�tv��!1� Flush with copious quantities of water. Consult a physician it irritation persists. Material is stable. Hazardous polymerization will not occut, Strong oxidizing agents, strong acids and alkatines. Strong oxidizing agunt9 at elevated temperatures and uncontrolled fumes. f imisr1 antnro ruraatdL6 410 item UW exeretth J41 /t713 ,}POLYGLASS USA Inc.: Corpvrste office & Mnnurtictering Facility Fort*, Nevada 80408 - Phone (775) 5758007 Fax (775) 575 -2314 - roll Free (800) 222 -07E2 - Manufacturing Facimmlas Hazleton, Pennsylvania 18202 - Phone (570) 3841230 Fax (570) 384-3282 - Tot Rao (8 00) 8941-41553 • Winter Haven, Florida 33880 - Phone (863) 287.5885 - Fax (883)297.5858 - Tali Free (886) 802.8017 www.polyglabs.corn - e- mail:custarnarservicee0olyglass .cam 92.18S:31'q,3t) . r. b141T T7ia: lC7 ri n Standard refuse disposal. tes re Was are classified ) as ny p - on- hazardous by U. S. Environmental Protection Agency (EPA) and as per definition by Resource Conservation and Recovery Act (RCRA), Follow all local, state, and tederal regulations governing waste disposal. Use protective equipment as described in Suction IX. Keep away from heat or flame and protect from the elements. • Wear safety glasses with side shields. Wear leather or cotton gloves (impervious) rN I Although 'rm .no __.. any . -._ U e well ,. normal conditions of product use does not warrant an special venttlat,on, u5n In well Ventilated area. nM. c{ ref�tilF�"If '� w'i' I�S al;; pir r c� None required unless used with hot asphalt. Use breathing apparatue (only NIOSH approved) when PELf7LV Is exceeded. REVIOWED FOR Shipping Labeling Labeling Required Hazard Class name Not regulated as a hazardous material for transport Not applicable Nono required fliaCtiViED Not applicable CITY TUKWILp MAY 2 0 2011 PERMIT c ENTER MAY 2 U 2U11 City oFukwllaf BUILDING rnviSInN Sand Is applied as an anti- Sticking agent to the membrane. Calcium carbonate ie used as a Compound stabilizer and Is encased in the asphaltic matrix, Fibrous glass filaments are encapsulated in modified asphalt coating. Dub to the nature of the speckle use ot these products, hazardous exposures are highly unlikely; however all relevant data has been provided for reference. Contact Palygl-ass USA at (775) 575 6007 Revision Data Ruason for Change r December 1, 2001 Now format 1 M1mA mt't�tii V "m °:tii'I .f.,%_ _MAIM '0.wi1- �'�Yi Information was obtained from sources, which we believe are reliable. However the information is provided without any representation or warranty, exprees or implied. regarding the accuracy or correctness, The conditions or methods of handling, storage, use and disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for toss, damage, or expense arising out ot or in any way connected with the handling, storage, use, or disposal of the product, POLYGLASS warmodrINe 1l6Sialue INDIMULATIIILIWYBrialti 50 /S0 39 d POLYGLASS USA, Inc.: Corporate Office $ Manufacturing Facility Fernley, Nevada 89408 - Phone (775) 675.6007 Fax (775) 575 -2314 - Tall Free (800) 222 -9782 - Manufacturing Facilities Hazleton, Pdnnaylvarua 18202 - Phone (570) 384 -1230 Fax (5701 384-3282 - Toll Free (800) 894 -4563 - Winter Haven, Florida 33880 - Phonn (853) 297.5885 - Fax (863) 297.5858 -Toll Free (868) 802.8017 www.polygt iss,com - e- mail :customsrServiceiapoIY9Isas.eom 9LLSESISZUT £O :OT TTOZ /61/50 " AI° &9, 46 tiJ\ q. 6114- It` k-aAs r 1 3 t a 2 3-Q" SF �� p \a" Q Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GOOD SHEPHERD CONSTRUCTION UBI No. 602829840 Phone 5092806838 Status Active Address 275 Patrick Rd License No. GOODSSC910PZ Suite /Apt. License Type Construction Contractor City Ephrata Effective Date 10/9/2009 State WA Expiration Date 10/9/2011 Zip 98823 Suspend Date County Grant Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date EVANS JR, JIMMY ROGERS Owner 10/09/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100100333 10/08/2009 Until Cancelled $12,000.00 10/09/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 BANKERS INS 46044000194570106 /15/2010 06/15/2011 $1,000,000.00 06/28/2010 1 CONKERS INS 46044000194570006 /15/2009 06/15/2010 $1,000,000.00 10/09/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni /bbip /Print.aspx 05/20/2011