Loading...
HomeMy WebLinkAboutPermit D11-148 - WESTFIELD SOUTHCENTER MALL - GALLERY - LANDLORD PORTIONGALLERY - LANDLORD PORTION 211 S 0 UTH CENTER MALL D11 -148 City Arukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 211 SOUTHCENTER MALL TUKW Suite No: Project Name: GALLERY - LANDLORD PORTION Permit Number: D11 -148 Issue Date: 03/05/2012 Permit Expires On: 09/01/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WAY SW #200 , SEATTLE WA 98106 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA 98580 Contractor License No: JEMCOI *033DD Lender: Name: Address: Phone: 206 624 -2777 Phone: 253 843 -2765 Expiration Date: 05/15/2013 DESCRIPTION OF WORK: CONSTRUCT NEW TENANT STOREFRONT, INTERIOR PARTITIONS, AND FINISHES FOR FUTURE TENANT Value of Construction: $40,000.00 Fees Collected: $1,400.95 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11-148 Printed: 03 -05 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: p92l0s� i2 I hereby certify that I have read and - . ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie . , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this pe Signatu e: Date:3—.5-/ a Print Name: / C A 1124: / // (i'/- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7110 D11 -148 Printed: 03 -05 -2012 7: All construction shall be done in confore with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 8: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 min). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) doc: IBC -7/10 D11-148 Printed: 03 -05 -2012 26: Sprinlders shall be installed under fixecljtructions over 4 feet (1.2 m) wide such as AD decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 28: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051.(ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth m Table No. 803.5 of the International Building Code. 33: Post address on storefront per approved Westfield standards. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: Arty overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -148 Printed: 03 -05 -2012 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.ci.tulavila.wa.us Building echar.cal Permit No. Plumbii Gas Permit No. Public Works Permit No. Project No. Ce use 0 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATT King Co Assessor's Tax No.: 12/.� Z�7— tO cD ! 0 Site Address: 2.1 1 S ol��G ��-- Q�ACu► Suite Number: 6 b Floor: Tenant Name: New Tenant: ❑ Yes [g. No Property Owners Name: iA.i ePc t,Al Mailing Address: 2.$00 5 eArcl -k- C.iG "(L__ r AU., S EPrnik ¶8 State Zip City CONTACT PERSON ctntaet wben your perm( ady to be issued Name: kiAcyMC jo Sa Day Telephone: Ss. 6 • & 2)4 27 7 7 Mailing Address: I•i O0D bE W4r. S 4 - Zed S T L City State Zip E -Mail Address: 14Pe(i4I er. 6 to IEWI PEX- • C-o M Fax Number' 20(0 • 62%1' 2-417 3 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plunnbing and Gas Piping (pg 5) Company Name: No'-. .0► i/ Ai/ Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip CUITECT OF R COF plans t sta b Architect of Reco Name: Mailing Address: / Contact Person: J W,t/10"— WO/, /S OA E -Mail Address: P./A- y,t./(ss &A SA1 S'f WitiA'a • G.o City — State Zip Day Telephone: 206 • ,42-V 2 ? 77 Fax Number: •2a (i • 6.2-s-/ • 2-4 73 ENGINEER OF RECORD — All plans rust be ive roped by Engineer of acor Company Name: /(1/4' Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: \ApplicationsWorms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Page 1 of 6 BU DING PEU 1V ±ORMATION'— 206- 431 -3670 Valuation of Project (contractor's bid price): $ 1-10 DOC, Existing Building Valuation: $ Scope of Work (please provide detailed information): 0771 -4( Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. d All Building Areas 9? re Footage >E Addition to Existing Structure Construction per IBC Type of Occupancy per MC 2' Floor Floors 43!72.7 2Y / dam sy, yy� 5' t4 Basement' Si Attached G sh d Garage Attached Carport; d Carport Covered Deck Uncover ck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Al 4 Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ,( No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: pg• SbeiL-s Automatic Fired m ❑ None ❑ Other (specify) Will there e storage or use o anima e, combustible or azardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q. 'Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 RMIT ' ' LICATION'NOT ica permits In thlsTapplicaho Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY 13Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A ^GEN�T- Signature: Print Name: 711.16"- Mailing Address: 4,040 Date Application Accepted: Date: Day Telephone: SP 6 6 2- 27 7 4444r -I / 2-00 S) : h `- f do c City See Zip 2--U2lt1 Date Application Expires: ulzult■ Q: Wpplications\Forms- Applications On Line\ -2006 - Permit Application. doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11 -148 Address: 211 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/26/2011 Applicant: GALLERY - LANDLORD PORTION Issue Date: Receipt No.: R11 -01082 Payment Amount: $525.30 Initials: JEM Payment Date: 05/26/2011 12:56 PM User ID: 1165 Balance: $812.65 Payee: S.M. STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16061 525.30 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 525.30 Total: $525.30 doc: Receipt -06 Printed: 05 -26 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11-148 Address: 211 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/26/2011 Applicant: GALLERY - LANDLORD PORTION Issue Date: Receipt No.: R12 -00903 Initials: User ID: Payee: JEM 1165 Payment Amount: $875.65 Payment Date: 03/05/2012 11:45 AM Balance: $0.00 JEM CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10976 875.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $875.65 808.15 63.00 4.50 doc: Receiot -06 Printed: 03 -05 -2012 AM" INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. "� A CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1po, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: / foizz Type(of, Inspect'on: t. Address: Date Called: Special Instructions: Date Wanted:. -- , �:a.m. J— - 1 p.m. Requester: Phone No 253- iao6 X1'24 Approved per applicable codes. Corrections required prior to approval. COMMENTS: D.P1J�1�' 1Inspor: IDate� ✓� � —� � REINSPECTION FEE REQUIREb Prior to next inspection. fee must be paid at 6300 Southcenter Blvd:. Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION RECORD [, _ Retain a copy with permi PERMIT NO. id Project: , , ( loin Type Insppectio0: Address: ?_ 1 I Sc. 404 Date Called: Special Instructions: • Date Wanted: -- -- 2 2 (? p.m. Requester: Phone,,�lo;/3 ! (0 -r -113 DApproved per applicable codes. Corrections required prior to approval. �o COMMENTS: (R) dJ ee o ASiAreji aid 6(1(2.' 4 i t _S�re f ' - (.2) ,_.1) 0 A J57— 1.)iiid4( . _EJ& f Ail' d1 ' -y r, a"-c--411) 4_461 Sd -'7--- 4 �t 4dif& (2 ( L / p4' ./`• A A r n REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • I.. i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. c CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 . Permit, inspection Request Line (206) 431 -2451 Project: &A k. e*`(' Type of Inspection: 0'1,O U SAC CE ! I.1 fi Address: 241 CC MM , Date Called: Special Instructions: • Date Wanted:. ot4 1 112 ap m Requester: Phone No: 2C Lo`o -Ci - + Approved per applicable codes. LJ Corrections required prior.to approval. �P COMMENTS: i 44 A 1111-Mi Dk ■j f sLii P.�',� `G4 J 's f ,i Inspect r: Date 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPEC ON NO. INSPECTION RECORD I i ^ (48' Retain a copy with permit PERMIT NO. .ITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec Type of spection: Address: Date Called: Special Instructions: Date Wantec(:. m. '" P.m. ! S Requester: -i 0 Phone N 253 -. (.1 otp -5921 ElApproved per applicable codes. E Corrections required prior to approval. i COMMENTS: VAITS Adit A- ALii4e d k.__ ct.kro .s d Q, -i 0 li/ -/, ` e/ t]V _J V01 ll n t Inspector: ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER • x s,. . ef� CITY OF TUKWILA FIRE DEPARTMENT �l \A ... 12-5 -051 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: x Cam.\ ,b� :: ,: • Sprinklers: -as Type of Inspection r,.t., . c L4$is , Address: Suite #: 2.1 \ 5o °10 c , --ctr V\ �M Conta erson :', • s c.‘c '' 1,--C e- 1 F Special Instructions: • 4) P.c,S ‘,/,' AL Phone No.: - pproved per applicable codes. Corrections required prior to approval. COMMENTS: :: ,: • Sprinklers: -as Inspector:v si ) Ev&c oytvcc L:\.-kiv.5 n \C ‘ T20 *o \ 1 °1 -11,x. r. u. ,. o•>k , . Gyvocp;.at1 v Z.) V- ,A , o k °10 c , Monitor: Qs.%a,A.Na,., Pre -Fire: 4) P.c,S ‘,/,' AL Sk Occupancy Type: AV\ Needs Shift Inspection: \ 5 Date: 5t 2AV Q_.. Sprinklers: -as Inspector:v si Fire Alarm: Gyvocp;.at1 v ,..•4L. Hood & Duct: Monitor: Qs.%a,A.Na,., Pre -Fire: Permits: Occupancy Type: AV\ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Date: 5t 2AV Q_.. Hrs.: \ ., Inspector:v si $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit AYR. �z -s —aS) • PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa: 98188 _ 206- 575 -4407 Project: G c.11 lc. / i Type of Inspection: v 5,r.•., Ie1 r....c_ C'vot. Address: 2/1 se X7411 Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval: COMMENTS: S . ill -, , v� Needs Shift Inspection: Sprinklers: Date: Fire Alarm: Hood & Duct: / Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: p»i f3 Date: 3),L /12 Hrs.: / $100.00 REINSPECTION FEE:REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: 1 Company Name: Address: City: 1 State: 1 Zip: Word /Inspection Recorcl Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • • S.M. STEMPER • ARCHITECTS A Professional Limited Liability Company February 1, 2012 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Correction Letter 1 to Revision 1 Permit Application No.: D11 -148 Tenant space 636 — Gallery - Landlord Portion Attention: Allen Johannessen We are writing in response to your Correction Letter dated January 25, 2012. We are demolishing the existing ceiling tile and grid, however it is in preparation for the installation of a new suspended acoustical ceiling per key note 1 and the Reflected Ceiling Plan. To better clarify the scope of work we have deleted key note 2 on sheet A3.0 and incorporated the demolition requirement as part of key note one. Since we are installing a new ceiling at the same location, the plenum will not be compromised, and thus will maintain the safety requirements of the plenum. If you should have any further questions please feel free to call. Sincerely, Wayne E. Johnson, AIA S.M. Stemper Architects, P.L.L.C. Cc: Scott Priester, Westfield Christian Faltenberger, Westfield Encl.: City of Tukwila letter — dated 01 -25 -2012 Revision Submittal Form Revised sheet A3.0 RECtiv u CITY OF TU FEB- 0`22012 PERMIT CENTER CORRECTION LTR# n�vi5iilN NO,.� ptl-I�k'� 4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106 . 206/624 -2777. FAX 206/624 -2973 • qs City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 25, 2012 Wayne Johnson S M Stemper Architects 4000 Delridge Wy SW, Suite 200 Seattle, WA 98106 RE: Correction Letter #1 to Revision #1 Development Permit Application Number D11 -148 Gallery — Landlord Portion — 211 Southcenter Mall Dear Mr. Johnson, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D11 -148 W:\Permit Center \Correction Letters \2011011-148 Corr Letter #1 to Rev #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: January 25, 2012 Project Name: Gallery — Landlord Portion Permit #: D11 -148 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 1 1 x 17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Originally the permit was approved for "New Tenant storefront, interior partitions, and finishes for future tenant ". The scope of work has now changed to include complete removal of the suspended ceiling. Depending where this store is located in the mall, many portions of the malls tenant ceilings are part of the HVAC's air plenum system. Therefore removal of the ceiling will compromise code compliance and safety requirements for plenum ceilings and the effectiveness of the plenum for adjacent tenants. Provide documentation or necessary plan changes to show the removal of the ceiling will not compromise any plenum systems, where this tenants existing ceiling is not part of a plenum system. Or provide a plan and documentation to indicate the existing plenum system shall remain intact during the tenant alterations. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. �P� • YI■ City of Tuk Vila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director January 24, 2012 Wayne E Johnson, AIA S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Application Extensions Westfield Mall Dear Mr. Johnson, This letter is in response to your written request for extensions to Permit Application Numbers D11-148 and D11-254. The Building Official has reviewed your letter and considered your request. It has been determined that the City of Tukwila will extend the permit application expiration dates an additional 90 days. The expiration dates of the applications are as follows: D11-254: April 23, 2012 D11 -148: May 21, 2012 (this is the second extension of this application) If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, j\if\A4A0a shall ician File: Permit No. D11 -148 and D11 -254 W:\Pennit Center\Extension Letters \Applications\2011\D11 -148 Application Extension #2.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 S.M. STEMPER • ARCHITECTS A Professional Limited Liability Company January 13, 2011 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Tenant Improvement Extension Permit Application No.: D11 -148 Space 636 Landlord Portion Attention: Bill Rambo We received your letter dated January 3, 2011, regarding the expiration date of February 20, 2011 for the current permit application listed above. We would like to thank you for notifying us about the expiration and thus request an extension. Since the initial application the proposed future tenant has changed and thus there are some minor revisions to the drawings. We are submitting the revised drawings (per per City of Tukwila requirements) to the City of Tukwila on Friday January 13, 2012. Therefore please accept this letter as our formal request for an extension to the application. It is our understanding that you will allow an extension up to 90 days, therefore we request that full extension is applied to the permit application so that the owner can finalize the leasing negotiations and select contractor to perform the work. If you should have any further questions please feel free to call. Sincerely, Wayne E. Johnson, AIA S.M. Stemper Architects, P.L.L.C. Cc: Scott Priester, Westfield Christian Faltenberger, Westfield Encl.: City of Tukwila letter — dated 1 -03 -2012 Im, D LA JAN 132012 PERMIT CENTER C� 02lut l2 6f1 0512I1, 4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106. 206/624 -2777 . FAX 206/624 -2973 c • s�. ✓ ✓✓ Z. Jim Haggerton, Mayor u !: Department of Community Development Jack Pace, Director 01 -03 -2012 WAYNE JOHNSON 4000 DELRIDGE WAY SW #200 SEATTLE WA 98106 RE: Permit Application No. D11 -148 GALLERY - LANDLORD PORTION 211 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 05/26/2011, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 02/20/2012. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D11 -148 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Cizy of Tukwila 1 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 14, 2011 Wayne E Johnson AIA S.M. Stemper Architects 4000 Delridge Wy SW, Ste 200 Seattle, WA 98106 RE: Request for Extension Development Application D11 -148 Gallery, Landlord Portion — 211 Southcenter Mall Dear Mr. Johnson, This letter is in response to your written request for extension to Permit Application D11 -148. The Building Official has reviewed your letter and considered your request. It has been determined that the City of Tukwila will extend the permit application expiration date an additional 90 days, through February 20, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, Jenn fer Marshall Permit Technician File: Permit No. D11 -148 W:\Pennit Center\Extension Letters \Applications\2011\D11 -148 Application Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • S.M. STEMPER • ARCHITECTS A Professional Limited Liability Company November 8, 2011 City of Tukwila, Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RE: Westfield Tenant Improvement Extension Permit Application No.: D11 -148 Gallery — Landlord Portion Attention: Bill Rambo We received your letter dated October 3, 2011, regarding the expiration date of November 22, 2011 for the current permit application listed above. We would like to thank you for notifying us about the expiration and thus request an extension. The Owner is currently negotiating the leasing requirements and thus not released notice to proceed for the contractor at this point. Therefore please accept this letter as our formal request for an extension to the application. It is our understanding that you will allow an extension up to 90 days, therefore we request that full extension is applied to the permit application so that the owner can finalize the leasing negotiations and select contractor to perform the work. If you should have any further questions please feel free to call. Sincerely, Wa e E. Johnson, AIA S.M. Stemper Architects, P.L.L.C. Cc: Scott Priester, Westfield Christian Faltenberger, Westfield Encl.: City of Tukwila letter — dated 10 -03 -2011 csig,43..e,yte ,tii 90 RE CITY OF Tumqui NOV 0 8 2011 PERMIT CENTER IP r ' ('P 4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106 . 206/624 -2777 . FAX 206/624 -2973 10 -03 -2011 • City of Tukwila 1 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director WAYNE JOHNSON 4000 DELRIDGE WAY SW #200 SEATTLE WA 98106 RE: Permit Application No. D11 -148 GALLERY - LANDLORD PORTION 211 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 05/26/2011, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 11/22/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtiona190 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D11 -148 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ERMIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -148 DATE: 02/02/12 PROJECT NAME: GALLERY - LANDLORD PORTION SITE ADDRESS: 211 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 X Revision # 1 after BEFORE Issued DEPARTMENT : O uilding Division MI Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02/07/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route $, REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ig,f Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 03/06/12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 ERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -148 DATE: 01/13/12 PROJECT NAME: GALLERY - LANDLORD PORTION SITE ADDRESS: 3 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 BEFORE Permit Issued DEPAR MEN 5: B �n. ,$`l1_ B din• Pivislon 11C7 o, • n'yu ub is Works /61-in MBA- I �� -Mfr of Fire Prevention IN Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete .k1 Incomplete DUE DATE: 01 /17 /12 Not Applicable Comments: Permit Center Use Only . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 02 /14 /12 Not Approved (attach comments) N*-- DATE: Permit Center Use Only 1 r CORRECTION LETTER MAILED: Departments issued corrections: Bldg rcSt Fire ❑ Ping ❑ PW ❑ Staff Initials: C /�� Documents /routing slip.doc 2 -28 -02 $EROT COORD COPV PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -148 DATE: 05/26/11 PROJECT NAME: GALLERY - LANDLORD PORTION SITE ADDRESS: 211 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTS: Building Division LI kill ,o ks Fi-7- (1 Public ks ,4W‘� ley �I e Fire Prevention annnning D vision s I v ❑ Permit Coordinator Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 171 Comments: Incomplete DUE DATE: 05/31/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 14_;g1, REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 06/28/11 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2-28-02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: y6 2.,,, ?'/ ?i Plan ChecWPermit Number: D1 1 - 1 48 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 • Revision # 1 before Permit is Issued R�LV F't(l CITY O ❑ Revision requested by a City Building Inspector or Plans Examiner FEB "022012 PERMIT CENTER Project Name: Gallery — Landlord Portion Project Address: 211 Southcenter Mall Contact Person: kA »t 8 JD/4,4 S /hone Number: 2 t ' - b v7- 27 2 Summary of Revision: P• ari D /rat u .dam %tea /5 6 7-2071. oF- ad Sheet Number(s): *� 0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Ce ter by: Entered in Permits Plus on i 0 Z \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 01/13/2012 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # t after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Landlord build -out at Vacant Space 636 Project Address2-! 'Southcenter Mall, Tukwila, WA 98188 D11 -148 ovrvngeleMailA JAN 131012 ''CMMII (;ESA Contact Person: Wayne E. Johnson Phone Number: (206) 624 -2777 Sununary of Revision: Owner (landlord) requested changes to vacant space 636 regarding the landlord build -out of the tenant space in preparation for future tenant. Revisions include the following: 1. Revised the interior partitions at the back stock room walls and restroom per tenant requirements. 2. Shown the desired location of electrical receptacles per future tenant request. (Electrical is design build) 3. Modified reflected ceiling plans to represent the changes in the floor plan. The following sheets were modified as stated below: Sheet A1.0 - Modified the back stock rooms wall and north wall of restroom. Sheet A3.0 - Modified reflected ceiling plan to represent the ceiling changes due to the revised wall locations. Revised the north elevation of the restroom to match the plans Sheet Number(s): A1.0, A3.0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: OkEntered in Permits Plus on d I `92l l2 H:'Applications \Forms - Applications On Line12010 Applications \7 -2010 - Revision Submittal.doc Created: 8-13 -2004 Revised: 7 -2010 a Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L£tl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name J E M CONSTRUCTION INC UBI No. 601770782 Phone 2538432765 Status Active Address 29506 8Th Ave S License No. JEMCOI'033DD Suite /Apt. License Type Construction Contractor City Roy Effective Date 3/4/1997 State WA Expiration Date 5/15/2013 Zip 98580 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MILLER, JAMES E President 01/01/1980 Amount Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SA7695 03/01/2002 Until Cancelled $12,000.00 03/19/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 American States Insurance Co 01C12205491 04/16/2011 04/16/2012 $1,000,000.00 04/13/2011 12 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2011 $1,000,000.00 04 /21/2010 11 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2010 $1,000,000.00 04 /17/2009 10 OOHIO CAS INS BL053040470 12/02/2008 12/02/2009 $1,000,000.00 11/20/2008 9 OOHIO CAS INS BL00353040470 12/02/2003 12/02/2008 $1,000,000.00 11/27/2007 Summons /Complaint Information Cause County Complaint Judgment Status Payment Paid By 10 -2- 11928 -6 BROOKDALE LUMBER INC InterPlead: No PIERCE Date: 08/16/2010 Amount: $10,795.92 Bond(s): SA7695 Date: Amount: $0.00 Dismissed Date: Amount: Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 03/05/2012 WESTFIELD MALL AT SOUTHCENTER Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK N PREPARATION FOR FUTURE TENANT. SITE INFORMATION: TENANT SPACE 636 TENANT ADDRESS: 211 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -9023 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: 835 S.F. TOTAL REVISED SQUARE FEET: 835 SF - NO ADDITIONAL TENANT SQUARE FEET AS PART OF TNIS WORK OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD (TABLE 1004.1.1): OCCUPANCY LOAD FACTOR - RETAIL AREA: 835 SF / 30 : 28 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) OCCUPANCY LOAD IS 28 THEREFORE ONE EXIT IS REQUIRED. ONE EXIT IS PROVIDED THEREFORE OK THERE IS ALSO A DOOR TO THE BACK OF HOUSE CORRIDOR THAT IS NOT PART OF THE EGRESS REQUIREMENTS MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED THEREFORE ACCEPTABLE EGRESS WIDTH - 28 (2) ■ 6 INCHES - PAIR OF 36" WIDE DOORS SHALL BE PROVIDED AT MALL STOREFRONT THEREFORE OK THERE IS AN ADDITIONAL EXISTING DOOR TO BACK OF HOUSE CORRIDOR THAT IS 36" WIDE TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE I5 LESS THAN 250 - THEREFORE OK SECTION 402A.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR ENTRANCE TO NE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WITHIN TENANT SPACE 16 LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.45.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY I -HOUR FIRE DOOR ASSEMBLY THAT IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.483. SECTION 402.12 - EACH TENANT 514ALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL PLUMBING REQUIREMENTS: SECTION 29022 - SEPARATE FACILITIES SHALL NOT BE REQUIRED IN MERCANTILE OCCUPANCIES IN WHICH MAXIMUM OCCUPANT LOAD 15 50 OR LESS. OCCUPANCY LOAD 15 28 THEREFORE SEPARATE FACILITIES 15 NOT REQUIRED. General Notes I. ALL WORK TO BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT 15 ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWNGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS 6140W ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS 5IH01LN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR 51•IO11N. DETAILS OF CONSTRUCTION NOT FULLY SHOUN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO RErLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VEI•`JFY SEQUENCE OF WORK WITH ONNER 10. ALL INTERIOR GM IS /11 TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE 411 FOR WATER RESISTANT GWB. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GM IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E -2A -10130 FIRE EXTINGUISHER PER 3000 5F AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 18. FUR:41514 AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON TINE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. 21. CONTRACTOR SHALL FURNISH AND INSTALL SPARE CONDUIT AND JBOX AS REQUIRED FOR PRIMARY SIGNAGE LOCATED ON THE EXTERIOR FACADE OF ENTRY DOOR FOR TENANT SIGN THAT IS PROVIDED BY THE TENANT. ALL WIRING AND FINAL CONNECTIONS SHALL BE BY THE TENANT AT TENANTS EXPENSE. CONTRACTOR SHALL ROUTE WIRING THROUGH FRAME OF STOREFRONT AS NEED TO ACCESS SIGN LOCATION. 22. CONTRACTOR SHALL FURNISH AND INSTALL SPARE CONDUIT AND J -5O5 AS REQUIRED FOR TENANT BLADE SIGN LOCATED AT EXTERIOR OF NEUTRAL PIER DESIGNATED BY TENANT AND LEASING COORDINATOR ALL (WRING AND FINAL OCNNECTIONS SHALL BE DI' TENANT AT TENANTS EXPENSE. Scope of Work SCOPE OF WORK SHALL INCLUDED THE LANDLORD BUILD OUT OF TENANT IMPROVEMENT TO AN EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER IN PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO - CONSTRUCTION OF NEW TENANT MALL STOREFRONT - CONSTRUCTION OF NEUTRAL PIERS AT TENANT MALL STOREFRONT - INSTALLATION OF TYPE X GYPSUM WALL BOARD ON EXISTING WALLS WITHIN TENANT SPACE AND PAINT EXISTING DESIGNATED WALLS TO A LEVEL 4 FINISH - INSTALLATION OF SUSPENDED ACOUSTICAL CEILING AND GRID TO BE COORDINATED WITH OWNER AND TENANT - CONSTRUCTION'OF INTERIOR PARTITIONS FOR TENANT SPACE - MODIFICATION TO EXISTING BATHROOM TO MAKE IT ADA COMPLIANT Vicinity Map NORTH Site Plan � I.-A r i E 1 Li &MIT REQUIRED FOR: /Mechanical LEiectrical Plumbing etas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall b made to the scope of work without prior approval of Tukwila Building Division. NOTE: Rvisions will require a new plan submittal and may include additional plan review fees. Project Directory WEA SOUTHCENTER, LLC 2800 Southcenter Seattle, WA 98188 I AN ANDREW CIARROCI-11 T - 20624610423 F - 206244.8601 FACILITIES MANAGER: CHRISTIAN FALTENBERGER T - 206246.0423 C - 253.611.9435 CFALTEN8ERCsER6WESTFIELD.COM ARCHITECT SM. STEMPER ARCHITECTS, PLL.C. 4000 Delrldge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2111 (206) 624 -2913 FAX wayne•emstemper.com FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Is acknowledged: B Date: :` City Of Tiukwila BUILDING DIVISION est& Southcen ter 633 Southoenter Poritway lUkwla, WA., 98188 -2888 208 - 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 AN M ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT ME ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCDON CARRIES THE 11115 DRAYANO IS INSTRUMENT' OF SERVICE, is THE PROPERTY ARCHITECOF T'S E NAME. AU. DESIGN AND OTHER INFORMATION SHOWN ON THE DRANNG ARE FOR USE ON ME SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (200) 824 -2777 • FAX (208) 624 -2973 �0 REG�- ERED 4i0. fj101 2 11 TENANT SPACE 636 211 SOUTHCENTER REVIEWED FOR CODE COMPLIANCE APPROVED JUN 15 2011 1)L_ City of Tukwila BUILDING DIVISION mervyi vs 2 LEVELS 3 LEVELS Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET A1.0 FLOOR PLAN AND DETAILS A2.0 ELEVATION, WALL SECTION, AND DETAILS A3.0 REFLECTED CEILING PLAN, SCHEDULES, AND DETAILS Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING JC x1G 3lEYELS • 3 LEVELS • 0c.L • *4(S /vat ioG NORTH W Z W U Z 0 J J J W LL. H W ISSUE MPROVEMENTS TENANT STOREFRONT LANDLORD AT TENANT SPACE 636 ISSUE PERMIT SET DATE: MAY 25, 2011 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA:1122.03.0' RI MALL COMMON AREA LEASE LINE ALUMINUM STOREFRONT WITH GLAZING 16' -0" Ls £% we, •• - cu,�i (E) FINS AT BULKHEAD TO -8E DEMOLI''- TYPICAL ALONG OREFRONT LEASE LINE EXISTING ADJACENT TENANT SPACE NO WORK THIS AREA —N FUTURE TENA RETAIL AREA -7 O 1' -4" : AFF n 1 VACANT TENANT SPACE I00 (E) NEUTRAL PIER - TO REMAIN S1 -11 3/4" BACK ROM 5' -4 3/4" MIN OUTLINE OF EXISTING BULKHEAD ABOVE LEASE LINE EXISTING ADJACENT TENANT SPACE NO WORK TH15 AREA --\\ -(E) ELECTRICAL PANELS TO R REMAIN (E) DOOR TO REMAIN EXISTING SACK OF HOUSE - CORRIDOR NO WORK THIS AREA - LEASE LINE (E) DOOR TO REMAIN FLOOR PLAN 16' -0" 1 /4" = 1' -0" 12" ALUMINUM REVEAL LEASE LINE M FURNISH AND INST,4 TO MATCLL STONE H MALL BASE CONCOURSE ADJACENT TENANT STOREFRONT ALUMINUM STOREFRONT AND GLAZING SYSTEM TYPICAL NEUTRAL PIER BACKER ROD AND CAULK - TYPICAL WALL ASSEMBLY PER WALL TYPE OUTLINE OF EXISTING SOFFIT AND FINS ABOVE EXISTING FINS TO BE DEMOLISHED, TYP. PAINT • LEVEL 4 FINSIH COLOR PER WESTFIELD 1 1/2" = 1' -0" ALUMINUM STOREFRONT AND GLAZING SYSTEM TYPICAL BACKER ROD AND CAULK - TYPICAL on ALUMINUM REVEAL FURNISH AND INSTALL STONE BASE LEASE LINE TO MATCH MALL CONCOURSE T6orr.. EXISTING NEUTRAL TO REMAIN FURNISH AND INSTALL GWB ON TENANT SIDE OUTLINE OF EXISTING SOFFIT AND FINS ABOVE - EXISTING FINS TO BE DEMOLISHED, TYP. PAINT - LEVEL 4 FINSIH COLOR PER WESTFIELD ADJACENT TENANT STOREFRONT NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 8 2012 City of Tukwila BUILDING DIVISION n FLOOR PLAN GENERAL NOTES: 1. DIMENSIONS EXISTING PARAMETERS. AND NOTIFY ARCHITECT 2. EXISTING WALLS AT TOP OF WALL 3. DATA/ELECTRICAL/MECHANICAL ELECTRICAL, AND PERMITTED UNDER 4. ALL MATERIALS REQUIRED FLAME ALSO ANY WOOD 402:5.4, 602, 603, 5. CONTRACTOR TO CONSTRICTION WESTFIELD FOR 6. CONTRACTOR CONSTRUCTION COMMON AREA. 1. CONTRACTOR BULKHEADS TO PAINTED TO LEVEL 8. AREAS DESIGNATED REMAIN AS CURRENT FORTH BY LOCAL ALARM SHALL AND NATIONAL S. CONTRACTOR OTHERWISE. CARPET COLOR HOPS 19454 MUST BE APPROVED 10. CONTRACTOR 'BLACK - BROWN' PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS OF ANY DISCREPANCIES. ADJACENT TO TENANT SPACE SHALL REMAIN- LEAVING MN. 6" GAP FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. ARE SHOWN FOR REFERENCE ONLY. DATA, MECHANICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND SEPARATE PERMIT. SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. COMPONENTS USED 514ALL BE FIRE RETARDANT TREATED WOOD. (IBC 4 2604) SHALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF CLARIFICATION. SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL SHALL PRIME, PRE , AND PAINT WALLS, NEUTRAL PIERS, SOFFITS, AND LEVEL 4 FINISH. NEUTRAL PIER AND MALL CONCOURSE AREAS TO BE 4 FINISH. COLOR TO BE DETERMINED. AS '(E) NO WORK' AND 'NO WORK / FUTURE TENANT SPACE' SHALL CONDITION. THE SPACE SHALL MEET THE REQUIREMENTS SET JURISDICTION FOR A VACANT SPACE. SPRINKLER SYSTEM AND FIRE PROVIDE COVERAGE FOR THE VACANT SPACE SET FORTH BY LOCAL CODES AND JURISDICTIONS HAVING AUTHORITY. SHALL FURNISH AND INSTALL CARPET THROUGHOUT UNLESS NOTED SHALL BE "INTERFACE' - FURROWS STYLE NUMBER 1666302500 QUARTER TURN INSTALLATION TILE (50 CM X 50 CM). SUBSTITUTIONS BY WESTFIELD MD ARCHITECT. SHALL FURNISH AND INSTALL 4" HIGH RUBBER COVE BASE ( ROPE P193). TYPICAL ALL ROOMS. 0 FLOOR PLAN KEY NOTES: 01 02 CONTRACTOR SHALL DEMO (E) FLOORING, PREP AND CLEAN EXISTING SLAB IN PREPARATION FOR FLOORING TO BE INSTALLED BY TENANT. SLAB SHALL BE FREE OF ADHESIVE, RESIDUE, AND ASSOCIATED ANCHORS ETC. CONTRACTOR SHALL FURNISH ANC INSTALL MALL TILE ALONG MALL COMMON AREA IN FRONT OF TENANT SPACE, PROVIDING A CLEAN TRANSITION LINE AT LEASE LINE. TYPICAL FULL WIDTH OF TENANT SPACE (E) TENANT DEMISING WALL TO REMAIN. CONTRACTOR SHALL DEMOLISH EXISTING WALL FINISHES, INCLUDING BUT NOT LIMITED TO SLAT WALL, WALL COVERING, TRIM, AND BASE. CONTRACTOR SHALL PRIME, PREP, AND PAINT EXISTING GWB TO LEVEL 4 FIN151-1. CON 1 TOR SHALL PRIME, - -; P, ,t, -4 NT WALL ASSEMBLIES TO LEVEL 4 FINISH. COLOR TO BE DETERMINED. NEUTRAL PIER CONSTRUCTION PER WALL TYPE AND DETAILS. CONTRACTOR SHALL PREP, PRIME, AND PAINT GM ALONG MALL CONCOURSE TO MATCH ADJACENT MALL CONCOURSE IN COLOR, TEXTURE, MD FINISH. O CONTRACTOR SHALL FURNISH AND INSTALL CARPET THROUGHOUT ROUGHOUT TENANT SPACE WITH T'4E EXCEPTION OF THE RESTROOM. CARPET 514ALL BE COORDINATED WITH WESTFIELD AND SHALL INCLUDE 4" RUBBER WALL BASE TYPICAL THROUGHOUT VACANT TENANT SPACE. O(E) 'PIPE COLUMN/ RAIN WATER LEADER' TO REMAIN. CONTRACTOR SHALL PROTECT THROUGHOUT CONSTRUCTION AND ADJUST NEW WALL ASSEMBLY LOCATION AS NEEDED TO ENCAPSULATE PIPE. (E) WALL MOUNTED SINK TO REMAIN AND /OR BE RELOCATED TO ALLOW CONSTRUCTION OF NEW WALL ASSEMBLY. CONTRACTOR SHALL FIELD VERIFY EXISTING LOCATION AND RELOCATE AS REQUIRED TO MAINTAIN ADA CLEARANCE AT SINK (E) WA - 0 T • : M'IN O CONTRACTOR SHALL N ALL DEMO EXISTING FLOORING AND FURNISH D INSTALL VINYL FLOORING THROUGHOUT INCLUDING 4" RUBBER COVER BASE. INTERIOR PARTITION WALLS AND DOORS TO BE DEMOLISHED IN THEIR ENTIRETY - 1 0 TYPICAL, INCLUDING BUT NOT LIMITED TO WALL COVERING BASE MD SURFACE M• 1 TED FIXTURES. 0 (E) STOREFRONT 0 AD -I TO BE DEMOLISHED IN ITS ENTIRETY ELECTRICAL SHALL FURNISH AND INSTALL CONDUIT, AND JBOX AND POWER WHIP FOR FUTURE ELECTRICAL TO BE LOCATED IN FUTURE TENANTS CASEWORK 03 04 01 (1 1O(E) 12 KEG' - L C • NEW WALL - REQUIRED EXIT ASSEMBLY V - WIDTH OF EXIT IN INCHES (WITHIN TRIANGLE) EXISTING WALL ASSEMBLY — .. — .. — LEASE LINE -_— WALL TYPES WALL TYP - EXISTING (I -HR RATED) UL DESIGN • U -465 - 5/8" TYPE X GUTS - METAL no FRAMING - 5/8" TYPE X GWB AT TENAT SPACE - WALL SHALL CONTINUE UP TO STRUCTURE W/ GWB STOPPING 6" FROM STRUCTURE CONTRACTOR SHALL VERIFY THE ;STATUS OF EXISTING WALL ASSEMBLY TO MEET MEET I -HR RATED ASSEMBLY REQUIREMENT. 2 WALL TYPE - RATED ASSEMBLY UL U -465 - 5/8" TYPE X GWB - 6" METAL STUD FRAMING AT 16" O.C. - 25 - 3 %" METAL STUD FRAMING AT 16" O.C. - 5/8" TYPE X G11.15 CONTRACTOR SHALL CONTINUE WALL ASSEMBLY UP TO STRUCTURE STOPPNG GM 6" SHORT OF STRUCTURE PER PLENUM REQUIREMENTS F Y. 3 5/8" 3 WALL TYPE - NON -RATED ASSEMBLY - 5 /8 " TYPE XGU - 3 % /e" METAL STUD FRAMING AT 16" O:C. - 5 /8 " TYPE XGUS CONTRACTOR SHALL CONTINUE WALL ASSEMBLY 6" ABOVE CEILING AND PROVIDE METAL STUD BRACING UP TO STRUCTURE AT 4' -0" MINIMUM. 4 WALL TYPE - NON RATED - 5/8" TYPE X GUS - 6" METAL STUD FRAMING AT 16" OC. CONTRACTOR SHALL CONTINUE WALL ASSEMBLY 6" ABOVE CEILING AND PROVIDE METAL STUD BRACING UP TO STRUCTURE AT 41 -0" MINIMUM. WALL TYPE GENERAL NOTES: JAN` 1, .8 2012 PERMIT CENTER 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO METAL STUD WIDTH AND THICKNESS, HEIGHT OF STUD FRAMING, CONDITION OF EXISTING GUS. 2. CONTRACTOR SHALL PREP AND PRIME ALL NEW TENANT SPACE GUS AND STORAGE AREA GM TO LEVEL 4 FINISH. 3. CONTRACTOR SHALL PREP MD PAINT ALL MALL CONCOURSE (NEUTRAL PIERS, BULKHEAD, ETC., RELATED AREAS TO LEVEL 4 FINISH. COLOR TO BE DETERMINED BY WESTFIELD. 4. CONTRACTOR SHALL MAINTAIN RATING OF ALL 1 -14OUR RATED ASSEMBLIES - EXISTING AND NEW ASSEMBLIES WITHIN AREA OF WORK 5. CONTRACTOR SHALL FURNISH AND INSTALL WHITE FRP PANELS WITHIN RESTROOM - ROOM 103 TO HEIGHT OF 4' -0" AFF FINISH FLOOR TYPICAL. DIV 111 WesIfle[c[ Sou th cen ter 633 Southoenter Parkway Thkwla, WA., 98186-2866 206- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WTHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FCR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 c7 W F- Z W U H 0 J J 0 J W LL C� W ISSUE REGIST ED AIr'T SCOTT EMPE STATE 0 W SHINGTON MPROVEMENTS 0 0 J 0 z J z O LL W 0 z z W IL AT TENANT SPACE 636 / \ JAN. 13, 2012 JUNE 6, 2011 ISSUE PERMIT SET DATE: MAY 25, 2011 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN DETAILS A1.0 SMSA:1122.03.0' PROPOSED LOCATION OF TENANT BLADE SIGN PROVIDE SPARE CONDUIT $ J -BOX - COORDINATE WITH TENANT EXISTING FINS TO REMAIN AT LOCATIONS ABOVE ADJACENT TENANT STOREFRONTS EXISTING FINS TO BE DEMOLISHED - PREP, AND PAINT BULKHEAD TO LEVEL 4 FINISH - TYPICAL Y Y Y Y Y Y Y YY Y Y Y Y EXISTING FINS TO REMAIN AT LOCATIONS ABOVE ADJACENT TENANT STOREFRONTS WIC Y Y Y Y Y Y Y Y Y TOP OF STOREFRONT 14' -0" BOTTOM OF MULLION I0' -0" / \A A A A A\ A A\ A A / METAL STUD FRAMING AND GWB NEUTRAL PIER. - PAINT LEVEL 4 FINISH 1/2" ALUM. REVEAL 1/2" ALUM. REVEAL (E) 1/2" ALUM. REVEAL TO REMAIN FINISH FLOOR 0' -0" 12" HIGH STONE TILE BASE - OFCI �J )9 NICK TEMPERED GLAZING - TYPICAL 2" STOREFRONT ELEVATION 1/2" = 1' -0" 4 1/2" X 4 1/2" CORNER ALUMINUM STOREFRONT FRAMING - TYPICAL JAMB DETAIL GLASS ENTRY DOOR 3" = 1' -0" fV DOOR HEAD DETAIL 1/2" THICK TEMPERED GLAZING TYPICAL HORIZONTAL ALUMINUM MULLION AT HEAD CONCEALED CLOSER TYPICAL STAINLESS STEEL DOOR HEAD 1/2" TEMPERED SAFETY GLAZING AT DOOR 3" = 11 -0" PATCH AND INSTALL MALL TILE TO LEASE LINE 1/2" THICK TEMPERED SAFETY GLAZING ALUMINUM STOREFRONT FRAME BEYOND STAINLESS STEEL DOOR BOTTOM SILL - TYPICAL FLOOR FINISH BY TENANT DOOR THRESHOLD DETAIL 3" = 1' -0" GLASS ENTRY DOORS TYP. WITH CONCEALED CLOSER ALUMINUM BREAK METAL MATCH COLOR OF STOREFRONT ALUMINUM STOREFRONT FRAMING AT I-EAD X" THICK TEMPERED GLAZING TYPICAL HEAD DETAIL 3" = 1' -0" ALUMINUM STOREFRONT FRAME - TYPICAL ALUM. STOREFRONT WITH MN. 1/2" GLAZING - TEMPERED METAL STUD FRAMING AT MALL BULKHEAD 5/8" GM TYPICAL - PRIME SOFFIT - LEVEL 4 FINISH BACKER ROD AND CAULK AT JAMB HORIZ. MULLION DETAIL 1/2" = 1' -0" X" THICK TEMPERED' SAFETY GLAZING TYPICAL ALUMINUM STO FRAMING AT SILL BACKER ROD AND CAULK AT SILL - FINISH FLOOR 12" HIGH STONE TILE BASE - OFCI DEMO (E) FINS AT TENANT STOREFRONT AND NEUTRAL PIERS LEASE LINE TOP OF !BULKHEAD 15' -bIEEE EXTRUDED ALUMINUM BREAK SHAPE ABOVE STOREFRONT TOP OF STOREFRONT 14'-01111 ALUMINUM TUBE AT HEAD 3 %II METAL STUD FRAMING AND GLIB - PAINT LEVEL 4 FINISH BOTTOM OF MULLION 101 -0" ALUMINUM TUBE FOR TENANT SIGNAGE ALUMINUM STOREFRONT FRAMIN WITH GLAZING FINISH FLOOR 01 -0" METAL STUD BRACING BACK TO STRUCTURE AS REQUIRED (E) BULKHEAD (E) STRUCTURE 3%8" DIAGONAL BRACING AT 4' -0" O,C. B.O. BULKHEAD 11' -0" \_ SUSPENDED ACOUSTICAL CEILING ILE AND GRID METAL STUD FRAMING AND GM BULKHEAD 4" RUBBER BASE f- CARPET TYPICAL TYPICAL WALL SECTION AT STOREFRONT 1/2" = 1' -0" 1/2" GLAZING IN FRAME 2" ALUMINUM STOREFRONT FRAME TYPICAL X" GLAZING IN FRAME VERTICAL MULLION DETAIL 3" = 1' -0" SEE WALL TYPE 5/8" GM METAL STUD JAMB HOLLOW METAL FRAME AND ANCHORAGE DOOR JAMB DETAIL 1 1/2" = 1' -0" DEMO (E) FINS AT TENANT STOREFRONT AND NEUTRAL PIERS LEASE LINE TOP OF BULKHEAD 15' -61111 EXTRUDED ALUMINUM BREAK SHAPE ABOVE STOREFRONT TOP OF STOREFRONT 14' -0NN ALUMINUM TUBE AT HEAD METAL STUD BRACING BACK TO STRUCTURE AS REQUIRED (E) BULKHEAD 3 %" METAL STUD FRAMING AND GWB - PAINT LEVEL 4 FINISH BOTTOM OF MULLION 101 -0" ALUMINUM TUBE FOR TENANT SIGNAGE GLASS ENTRY DOORS TYPICAL FINISH FLOOR 0' -0" MALL STOREFRONT STOREFRONT DESCRIPTION - EXTRUDED ALUMINUM STOREFRONT - KAWNEER TRIFAB 451 - 2" WIDE BY 4 1/2" DEEP FRAMING - FRONT GLAZED - FRAME FINISH SHALL BE ALUMINUM CLEAR ANODIZED - GLAZING SHALL BEE MIN. 1/2" THICK TEMPERED SAFETY GLAZING - TYPICAL - CLEAR TEMPERED GLASS PER HEIGHT AND GLAZING REQUIREMENTS SEE WALL TYPE 5/8" GWB METAL STUD HEADER HOLLOW METAL FRAME AND ANCHORAGE 3 %" p IAGONAL BRACING AT 4 -0" O.C. B.O. BULKHEAD - 11' -0" - SUSPENDED ACOUSTICAL CEILING TILE AND GRID METAL STUD FRAMING AND GM BULKHEAD • 4" RUBBER BASE CARPET TYPICAL TYPICAL WALL SECTION AT ENTRY 1 /2" = 1' -0" VERTICAL MULLION DETAIL 1 1 /2" = 1' -0" D REVIEWED FOR CODE COMPLIANCE APPROVED JUN 15 2011 City of Tukwila BUILDING DIVISION LA MAY.26 2011 PERMIT CENTER 13siiie[tf Southcenter 633 Southcenter Parkway 1Uke7a, WA., 98188 -2888 208- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS WANING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED W TROUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUC ➢ON CARRIES THE ARCHITECTS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN ON THE DRAVANG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERYASE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 824 -2973 ISSUE ISSUE DATE: MPROVEMENTS TENANT STOREFRONT LANDLORD AT TENANT SPACE 636 rx wr F— co zc) W < F- < � J O— N F._ PERMIT SET MAY 25, 2011 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ ELEVATION WALL SECTION AND DETAILS A2.0 SMSA:1122.03.0d METAL STUD FRAMING AND GWB BULKHEAD AT 10' -0" AFF EXISTING ADJACENT TENANT SPACE NO WORK THIS AREA MALL COMMON AREA ALUMINUM STOREFRONT WITH GLAZING e.L�J�L�L. Lti�tLIiL�L 1LLili LwL L✓�1a t[YL�t�.tvLala L�L�1w.Lf.L�LiL • • ��AN3��: ice::: • : :arMPT 08 EXISTING BACK OF HOUSE - CORRIDOR NO WORK 11-4I6 AREA OUTLINE OF EXISTING BULKHEAD ABOVE (E) FINS ,AT BULKHEAD TO BE DEMOLISHED EXISTING ADJACENT TENANT SPACE NO WORK THIS AREA REFLECTED CEILING PLAN 1 /4" = 1' -0" INTERIOR ELEVATIONS 1 /2" = 1' -0" DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB THRESH 100 COMMON MALL - TENANT SPACE GLASS - FR 3' -0" x 10' -0" 1/2" GLASS N/A N/A N.R. 1/A20 4/A20 9/A2.0 I 2, 3, 4, 5 101 TENANT SPACE - VIEWING ROOM FLUSH - 3' -0" x T -0" 13/4" WOOD N/A W1. N.R 12/A2.0 11/42.0 - 2 102 VIEWING ROOM- BACK ROOM FLUSH - 3' -0" x T -0" 1 3/4" WOOD N/A WM. N.R. 12/42.0 11/42.0 - 2 102A BACK ROOM - CORRIDOR FLUSH - 3' -0" x T -0" 1 3/4" WOOD WA EX4ST. 1-HR - - - - I 103 VIEWING ROOM - RESTROOM FLUSH - 3' -0" x 1' -0" 1 3/4" WOOD N/A HAM. N.R. 12/A2.0 II /42.0 - 2 REMARKS AINE3REVIATIONS 1. EXISTING DOORS ARE TO REMAIN - NO MODIFICATIONS TO DOORS OR FRAMES AL ALUMINUM 2: FURNISH AND INSTALL TILE TO MALL CONCOURSE TILE TO LEASE LINE FL FLUSH DOOR 3. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS MEETING ALL REQUIREMENTS FR FRAME FOR GLASS DOORS INCLUDING ADJACENT GLAZING ALONG MALL CONCOURSE. HM HOLLOW METAL 4_ PULLS TO BE STAINLESS STEEL NR NON -RATED 5. DOORS TO HAVE SIGN (I" HIGH LETTERS) LOCATED ABOVE DOORS WITHIN VACANT SPACE STOR STOREFRONT STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" WD WOOD 6. 2" HOLLOW METAL FRAME INCLUDING UL LABEL PER REQUIRED RATING �Th HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER (CRL) 2 PRS. 1" DIA. 18" BACK TO BACK PULLS (CRL GLASS MOUNTED STRAIGHT) 2 QTY. DEAD BOLT FLOOR RAIL LOCK (CRL DOOR FLOOR RAIL LOCK) 2 QTY. CYLINDER (CRL MORTISE KEYED CYLINDER) FINISH OF HARDWARE AND STILES SHALL BE BRUSHED STAINLESS STEEL LEASE LINE TOP OF STOREFRONT 15' -6"" EXTRUDED ALUMINUM BREAK SHAPE ABOVE STOREFRONT - MATCH STOREFRONT FRAME 3%8" METAL STUD FRAMING AND GWB - PRIME TO LEVEL 4 FINISH PROVIDE DIAL. BRACING AT MINIMUM 4' -0" O.C. TOP OF STOREFRONT I4' -OILII ALUMINUM STOREFRONT FRAMING AND GLAZING (E) FINS AND PLYWOOD TO BE DEMOLISHED ALONG TENANT BULKHEAD AND ACROSS ADJACENT NEUTRAL PIERS GROUP 2 - WOOD DOOR 1 - LEVER TYPE HANDLES - MANUFACTURER: L- SERIES , 17 LEVER HANDLE, SATIN CHROME 3 - BUTT HINGES 1- UJALL STOP 1 SET - SILENCER 1- MORTISE CYLINDER - FUNCTION FINISH OF HARDWARE SHALL BE BRUSHED 11///410a I VACY ICKEL 1,k,n thtk W1 fltb frf 141 (E) BULKHEAD TO REMAIN BULKHEAD DETAIL 1 1 /2" = METAL STUD FRAMING AND GUB BULKHEAD - PAINT LEVEL 4 FINISH COLOR TO BE DETERMINED %< ACCESSORY SCHEDULE Ol 36" GRAB BAR MOUNTED AT 33" AFF. -- BOBRICK 8 -6806 - SATIN FINISH 0 TOILET PAPER DISPENSER -- BOBRICK 8 -2888 CLASSIC SERIES MULTI -ROLL MOUNTED WITH CENTERLINE 8" IN FRONT OF TOILET AT 15' MIN. AFF. O3 VERTICAL 18" GRAB BAR -- BOBRICK 8 -6806 - SATIN FINISH MOUNTED AT 40" AFF AND 40" FROM BACK WALL. O42" GRAB BAR -- BOBRICK 13-6806 - SATIN FINISH MOUNTED AT 33" AFF. O 24" X 36" MIRROR AT 40" AFF. BOBRICK 6 -293 2436 O RECESSED PAPER TOWEL DISPENSER -- BOBRICK MODEL 3900 CLASSIC SERIES LILLY RECESSED WITH 12 GALLON TYRASH RECEPTACLE O PLUMBING PIPE PROTECTOR -- TRUEBRO MODEL '103 O TOILET SEAT COVER DISPENSER -- BOBRICK 6 -221 CLASSIC SERIES g. UNDER COUNTER MOUNTED SOAP DISPENSER - KOHLER MODEL - k -1895 - POLISHED CHROME FINISH _ 10 WALL MOUNTED LIGHT FIXTURE - RE: ELECTRICAL 0 SANITARY NAPKIN DISPOSAL -- BOBRICK 8 -354 CLASSIC SERIES - RECESSED 12 (E) WATER CLOSET TO REMAIN. (E) WALL MOUNTED LAVATORY AND FAUCET TO BE RELOCATED 13 AS REQUIRED TO MEET ADA CLEARANCES AND REQUIREMENTS. NOTES: 1. CONTRACTOR SHALL FURNISH AND INSTALL 16 GA FLAT STRAP BACKING AT WALL LOCATIONS DESIGNATED TO RECEIVE UJALL MOUNTED FIXTURES INCLUDING BUT NOT LIMITED TO: GRAB BARS, MIRRORS, AND LIGHTS. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. RESTROOMS FIXTURES SHALL BE MOUNTED IN ACCORDANCE TO ADA AND LOCAL JURISDICTIONAL REQUIREMENTS 3. RESTROOM SHALL INCLUDE 5' -0" CLEAR FLOOR AREA TURNING RADIUS AND A 30" X 48" CLEAR FLOOR AREA AT SINK CLEARANCES ARE SHOWN IN PLAN AS 04514ED LINES FOR REFERENCE. RUBBER COVE BASE - TYPICAL A. NORTH ELEVATION PAINT GWB TYPICAL LEVEL 4 FINISH 48" HIGH FRP PANEL TYPICAL —\\ RUBBER COVE B. EAST ELEVATION BASE 'TYPICAL REVIEWED FOR CODE COMPLIANCE APPROVED FEB 08 2012 City of Tukwila BUILDING DIVISION 3 REFLECTED CEILING PLAN GENERAL NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. CONTRACTOR SHALL SEISMICALLY BRACE SUSPENDED CEILING GRID SYSTEM PER LOCAL JURISDICTIONAL REQUIREMENTS. 3. LIGHTING IS SHOWN FOR REFERENCE ONLY AS ELECTRICAL IS DESIGN BUILD BY CONTRACTOR. CONTRACTOR SHALL COORDINATE WITH DESIGN BUILD LIGHTING PLANS AND WESTFIELD THROUGHOUT CONSTRUCTION. 4. MECHANICAL DIFFUSERS ARE SHOWN FOR REFERENCE ONLY AS MECHANICAL IS DESIGN BUILD BY CONTRACTOR CONTRACTOR SHALL COORDINATE WITH DESIGN BUILD MECHANICAL PLANS AND WESTFIELD THROUGHOUT CONSTRUCTION. 5. EGRESS PATHWAY LIGHTING, INCLUDING EXIT SIGNS SHALL BE PROVIDED AS REQUIRED FOR VACANT SPACE PER REQUIREMENTS SET FORTH BY LOCAL JURISDICTION. 6. CONTRACTOR SHALL SUPPORT AND BRACE ANY AND ALL CEILING COMPONENTS INCLUDING BUT NOT LIMITED TO CEILING GRID, LIGHT FIXTURES, ETC PER SEISMIC RESTRAINT REQUIREMENTS SET FORTH BY 2009 IBC AND ASSOCIATED CODES AND REQUIREMENTS PER LOCAL JURISDICTIONS HAYING AUTHORITY. 1. CONTRACTOR SHALL PROVIDE REQUIRED SPRINKLER AND FIRE ALARM PROTECTION WITHIN VACANT TENANT SPACE AS REQUIRED BY LOCAL JURISDICTION. 8.. CONTRACTOR SHALL COORDINATE HEIGHT OF CEILING WITH EXISTING CEILING HEIGHT TO MINIMIZE IMPACT TO EXISTING INFRASTRUCTURE ABOVE CEILING, INCLUDING BUT NOT LIMITED TO SPRINKLER HEADS, LIGHTING, DUCTWORK, AND FIRE ALARM. 9. SUSPENDED CEILING TILE AND GRID SHALL BE USG FISSURED 2 X 2 X %" PANELS WITH DONN DX/DXL GRID %" WIDE. USG ITEM NUMBER 560, COLOR OF PANEL AND GRID 51-1ALL BE WHITE. SUBSTITUTIONS MUST BE APPROVED BY WESTFIELD AND ARCHITECT. 10. CONTRACTOR SHALL LOCATE CEILING AT HEIGHT SIMILAR TO EXISTING CEILING LOCATION TO AVOID MAJOR CHANGES IN SUPPORTING UTILITIES LOCATED WITHIN CEILING, INCLUDING BUT NOT LIMITED TO SPRINKLER HEADS, LIGHTING, DIFFUSERS, SPEAKERS ETC. REFLECTED CEILING PLAN KEY NOTES: 01 2 X 2 SUSPENDED ACOUSTICAL TILE AND GRID. GRID AND LIGHT FIXTURES SHALL BE SEISMICALLY BRACED PER IBC 2009. GRID SHALL BE MINIMUM 15/16" WITH SUPPORT GUY WIRES PER MANUFACTURES AND LOCAL JURISDICTION. SPRINKLER HEADS SHALL BE PER FIRE SPRINKLER CONTRACTOR TO BE LOCATED WITHIN CENTER OF TILES, TYPICAL. ALL ASSOCIATED LIGHTING AND MECHANICAL DIFFUSERS ARE SHOWN FOR REFERENCE ONLY. FIELD VERIFY EXISTING CEILING HEIGHT AND COORDINATE HEIGHT TO MINIMIZE IMPACT TO SPRINKLER PIPING, DROPS, AND HEADS. CONTRACTOR SHALL DEMOLISH EXISTING SUSPENDED ACOUSTICAL CEILING TILE AND GRID IN ITS ENTIRETY, INCLUDING BUT NOT LIMITED TO LIGI-ITING, POWER, MECHANICAL DIFFUSERS, SPEAKERS, SPRINKLER HEADS, ETC. 5 REQUIRE • • : 1 - A AT •' •, W IL • E • . • ..- - 02> NOT USED - --- N05 CONTRACTOR SHALL PRIME, PREP, AND PAINT GWB TO LEVEL 4 FINISH. SUSPENDED LAY -N 2 X 2 LIGHT FIXTURE WITHIN SUSPENDED CEILING GRID PER ELECTRICAL DESIGN BUILD CONTRACTOR. FIXTURE TYPE, QUANTITIES, AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES AND JURISDICTION. MECHANICAL SUPPLY DIFFUSER PER MECHANICAL DESIGN BUILD CONTRACTOR DIFFUSER TYPE, QUANTITY AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR 06 MECHANICAL RETURN DIFFUSER PER MEG- IANICAL DESIGN BUILD CONTRACTOR. DIFFUSER TYPE, QUANTITY AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR 0> RECESSED DOWN LIGHT PER ELECTRICAL DESIGN BUILD CONTRACTOR. FIXTURE TYPE, QUANTITIES, AND LOCATION ARE SHOWN FOR REFERENCE ONLY AND SHALL BE COORDINATED WITH DESIGN BUILD CONTRACTOR TO MEET LOCAL CODES AND JURISDICTION. 08 (E) WALL MOUNTED SHELF TO REMAIN. CONTRACTOR SHALL EXTEND SHELF TO THE NORTH WALL AND MAINTAIN REQUIRED SUPPORT FOR EQUIPMENT. 0n (E) EXHAUST FAN TO BE RELOCATED AND INSTALLED WITHIN NEW CEILING TILE AND GRID. 10 (E) SURFACE MOUNTED TRACK LIGI-ITING TO BE RELOCATED AND INSTALLED ON NEW CEILING TILE AND GRID. CONTRACTOR SHALL RE -LAMP ALL FIXTURES ASSOCIATED WITH TRACK LIGHTING. RE: ELECTRICAL FOR POWER REQUIREMENTS. CORRECTION iv NO1 REVISION JL 1' -4" LPAINT GWB TYPICAL LEVEL 4 FINISH —\ 3' -4" 3' -6" .1 2 O, 7,1 co 48" HIGH FRP PANEL TYPICAL LRUBBER COVE / C. SOUTH ELEVATION BASE - TYPICAL 11 1 3'-0" PRIME GM TYPICAL LEVEL 4 FINISH D. WEST E 1 F�fctly CITY OF TUkk.A FEB'0 2 2012 PERMIT CENTER ELEVATIO RUBBER COVE BASE - TYPICAL D11_14443 WslIle[tf Southcenter 033 Southcenter Parkway ThKWa, WA., 98188 -2888 200- 246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. ALL DESGN AND OTHER INFORMARON SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (206) 624 -2973 W Z W U 2 0 to J J D J W L.L W ISSUE MPROVEMENTS TENANT STOREFRONT LANDLORD AT TENANT SPACE 636 /°\ FEB2,2012 \ JAN. 13, 2012 JUNE 6, 2011 ISSUE PERMIT SET DATE: MAY 25, 2011 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ REFELECTED CEILING PLAN SCHEDULES AND DETAILS A3.0 SMSA:1122.03.0''