HomeMy WebLinkAboutPermit D11-154 - KIEHLBAUCH RESIDENCE - IMPROVEMENTKIEHLBAUCH
RESIDENCE
15630 47 AV S
Dl 1 -154
City oPI'ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206. 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 8108600802
Address: 15630 47 AV S TUKW
Suite No:
Project Name: KIEHLBAUCH RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -154
Issue Date: 06/30/2011
Permit Expires On: 12/27/2011
Owner:
Name: KIEHLBAUCH JOSEPH A +MARILYN
Address: 15630 47TH AVE S , TUKWILA WA 98188
Contact Person:
Name: ROBERT HOLMGREN
Address: 5500 S DAWSON ST , SEATTLE WA 98118
Contractor:
Name: NORTHWEST CONST & SUPPLY INC
Address: 4322 SW HOLLY ST , SEATTLE WA 98136
Contractor License No: NORTHCS0005N
Phone: 253 - 261 -5114
Phone: 206 - 937 -4837
Expiration Date: 08/24/2012
DESCRIPTION OF WORK:
REMOVE ZERO CLEARANCE FIREPLACE, REFRAME NEW OPENINGS FOR (2) NEW PICTURE WINDOWS AND (1) SLIDING
PATIO DOOR. RESIDE WITH HARDIE PLANK SIDING, INSULATE, SHEETROCK, TAPE & TEXTURE INTERIOR OF WALL
(EAST END OF HOUSE). REWIRE OUTLETS & SWITCHES WHERE NECESSARY
Value of Construction: $15,000.00 Fees Collected: $622.10
Type of Fire Protection: International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D11-154 Printed: 06 -30 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be compile
N
N
N
• •
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
The granting of this permit does not p
construction or the performance of work.
to this permit.
Signature:
Print Name:
Date:
Public:
Non - Profit: N
Public:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
t /FAT V• gL,„-N)
Dated 3O ill
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
doc: IBC -7/10
D11-154 Printed: 06 -30 -2011
7: VALIDITY OF PERMIT: The issuance or g of a permit shall not be construed to be mit for, or an approval of,
any violation of any of the provisions of the g code or of any other ordinances of the of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11-154 Printed: 06 -30 -2011
CITY OF TUK A
Community Develo ment Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Per No. j t\-.-- 1 S
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
�Q King Co Assessor's Tax No.:ZIO $60 O
Site Address: 15'636 l u rii / 1 n .S . %[7 kVU/ C-4 Suite Number: Floor:
Tenant Name: l 6N e4Oril4 New Tenant: ❑ Yes ❑ .. No
Ifi Property Owners Name: Si; 1U'. AS 44 b i)0
Mailing Address: l 56 3D 119 ?. /iv/? S 6
City
ti)4,1 J4
State
9JocrJ Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: 1Qo, o,�° 1-41 Iw'246-A)
Mailing Address: /�
E -Mail Address: / 1% lib C l -4/u'k) C. 40t, ,05
on ,S-0 D4 /oS1)J sr
Day Telephone: oZ5 3 g.6/ S //4L
City fate Zip
Fax Number: g() � 72-2- c3/
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: /U 0/144,1 ( ERc (U /OS- /LILG ?l ph) 25 /DPI L l.) _xJ e_. ,
Mailing Address: 17t 2Z Sew- /Q GL Y,S"T. 5-
I4- Ce 1.u/ lI gJ13 t
/� 1 City State Zip
r Contact Person: R 6 r L7 � L M- &4 )\) Day Telephone: 2--$ 3 2j, / 57/ l�
E -Mail Address: Q a /-/)1 4,6- A) 40-1 Az, i 6 ,, , Fax Number: Z) 6 -%7 2- Gf 3
Contractor Registration Number: N 0 A 7-iy 0 (9 ow 5 Expiration Date: 4f— 31 a.01)
ARCHITECT OF RECORD — All plans must be stamped by Architect of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
ENGINEER OF RECORD — All plans must be stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\Applications\Porms- Applications On Line \2010 Applications \7-2010 - Permit Application.doc
Revised: May 2011
bh
Page 1 of 6
BUILDING PERMIT INFORMATION — 206 - 431 -3670
Valuation of Project (contractor's bid prig $ 15/ 000 , 00 Existing Building Valuation: $ _/0, 00
Scope of Work (please provide detailed information): f /vt,v U Z 0 (�L.& —INA, 6-- ¢ .
g ,,,t5-,_, tp a v/ uL�e 6,2_ A tki ?) cZd, Wh� h tvj J � l 5-i i *
1.
6 ✓v , 740'S 'S wl,(6'6 /UJ(.,Fj -S'' /
Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application :doc
Revised: May 2011
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
l' Floor
2nd Floor
3td Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application :doc
Revised: May 2011
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Allicable to all permits in this application •
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE 93 AUTH/9 Z D AGENT:
Signature: 44J i
Print Name: i4E3l -j v O/ jvt,(, A)
Mailing Address:
Date: 6 )-- d 11
Day Telephone: 01S3 a� / c / /5L-
Date Application Accepted:
Date Application Expires: I 1 1 —,G/
Staff Initials: pi
H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc
Revised: May 2011
bh
Page 6 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 8108600802
Address: 15630 47 AV S TUKW
Suite No:
Applicant: KLIENBAUCH RESIDENCE
RECEIPT
Permit Number: D11 -154
Status: PENDING
Applied Date: 06/02/2011
Issue Date:
Receipt No.: R11 -01111
Payment Amount: $622.10
Initials: WER Payment Date: 06/02/2011 01:04 PM
User ID: 1655 Balance: $0.00
Payee: JOSEPH KLIENBAUCH
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 00521C
ACCOUNT ITEM LIST:
Description
622.10
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100
000.345.830
640.237.114
Total: $622.10
374.30
243.30
4.50
doc: Receipt -06 Printed: 06 -02 -2011
•
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 5(206) 431 -3670
Permit Inspectiori'Request Line (206) 431 -2451
- s4
Pto a
cil
TY t:lns ion
Add r �s .7 ,�4 _1e
LOA,. -instructions:
Da te Xg -s--i s .
g J
'
Speciaa
Date Wanted:+.
t —
t!
cam..
p.m.
Requester:
Phone No:
Approved per applicable codes. 1 Corrections required prior to approval.
COMMENTS:
LoI dyAi ,0
•
1Date: / Z. !� �
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
• paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
7
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
bit -tom
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Pr ject:
K. Eu-L
p-C1- pG i. n A p (.0 /ti vu-J 4-77 n (!/
Typ f Ins ecti n:
T vP I)
go . ('O r. n (
Address: r`Z„
1S(41 30
Date Called:
(► ( 1-1-1 vie 1 4i - ,0 --1.'k e
Special Instructions:
�-� (r r
f
Date Wanted:.
,2�—( f (p�m'
Requester:
Phone No:
_ ZS3 -Z
( -5((.4
Approved per applicable codes. rections required prior to approval. 3
COMMENTS:
p-C1- pG i. n A p (.0 /ti vu-J 4-77 n (!/
CiC) / 1Mr�r (, r 1 �I.{i Ian U ,'AI' 1 � lr,�
�(y�.,j_' � /
ep , )e�2r f r--"..4 .AAsT /V
�'‘ et-f r ! Vtec_7 Li/(/ ( P..131-41(
(► ( 1-1-1 vie 1 4i - ,0 --1.'k e
____, n 4
ilnsp� cue tor:
C
• (Date � _2_4._
u �
❑ REINSPECTION FEE REQU)R D. Prior to next inspection. fee must be
paid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
_iv 1/
Prde t:•
p p aQ PI
Type of s _ ecti44n.: t
Address: 5- 3 0
41
4-
Date Called:
Special Instructions:
`T
F4_5
Date Wanted:
Requester:
PhoZ.S3_2-
f -.5" //le
Approved per applicable codes. O Corrections required prior to approval.
COMMENTS:
p p aQ PI
ere D ci..H A tA -1 It .5 .
`T
F4_5
REINSPECTION FEE REQUIRfrD. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF' TUKWILA BUILDING DIVISION C I -�
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
r.1"'I .. • -• ff.r
air —Is-,
Pro'ect:.
464 U�,
, .
rz
Type of Inspection:
5keetA
£tT)A-4 A L/ .nL ) n ( . ASJ 14
Address: Y 4
15 ip30 9'7 S,
Date Called:
Special Instructions:
O S f 0 4 - 0(
j
`�►
Date Wanted:
—7-1— t /
a.m.
p.m
Requester:
Phone —57
/4
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
hr"1"";,A 1 A p fa ../A( )1'‘ WA'� .S �',� r
£tT)A-4 A L/ .nL ) n ( . ASJ 14
fv )tb J C.- p r-t 4& S 14 ►. zA
Inspector:
D-__41A
Date: -7_ _)+ 1.1
n REINSPECTION FEE REQUIRED Prior to next inspection, fee-must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
•
:
7'
EXISTING DRIVE & PARKING
23'
23'
EXISTING HOUSE
IMO
EXISTING DECK
12
TOOL
SHED
1102 /22/V
ri
46'
8
15
GARDEN
SHED
NOISNHOf 19'
8
128.02'
REVIEWED FOR
CODE COMPLIANCE
APPROVED
' JUN 2 4 2011
•
City of Tukwila
BUILDING DIVISION
311.23'
OWNER:
JOE KIEHLBAUCH
15630 q"Flve 5
*MK, WA. OSOPIV.
wNwil• WO re
Tr-
SCALE 1" = 20'
NO CHANGE IN FOOTPRINT
PARCEL #810860 0802
SCOPE OF WORK
REPLACE 2 WINDOWS
AND 1 GLASS DOOR
RECEIVED
611'1514 JUN O2ZO„
PERMIT CENTER
AL JOHNSTON DESIGN'S LLC.
6928 15th AVENUE SE.
LACEY, WA. 98503
360-458--4600
FAX 360 - 491 -3176
8.64'
IgIPJ COPY a
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -154 DATE: 06 -02 -11
PROJECT NAME: KIEHLBAUCH RESIDENCE
SITE ADDRESS: 15630 47 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENTS:
Building bivisionn A 69'0 Puttflc Worlkks I
Fire Preve tion Ln 9 DiviCon te-i-
Permit Coordinator a
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
DUE DATE: 06-07-11
Complete Incomplete ❑ Not Applicable n
Comments:
Permit Center. Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required n No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions Not Approved (attach comments) El
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 07- 05-11
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople liter Friendly Page
1
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name NORTHWEST CONST & SUPPLY INC UBI No. 602060240
Phone 2069374837 Status Active
Address 4322 Sw Holly St License No. NORTHCS000N5
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 8/25/2000
State WA Expiration Date 8/24/2012
Zip 98136 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
e
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
NORTHCS077DZ
NORTHWEST CONST
& SUPPLY
Construction
Contractor
General
Unused
3/9/1993
8/24/2000
Archived
NORTHVL113C3
NORTHWEST VINYL
LINE
Construction
Contractor
Siding
Unused
2/23/1989
6/28/1992
Archived
CONSTSD158KL
CONST SUPPLY &
DESIGN COMPANY
Construction
Contractor
General
Unused
5/13/1985
1/13/1987
Archived
HOLMGRV222MSHOLMGREN, ROBERT
V
Construction
Contractor
General
Unused
7/10/1978
11/14/1985
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
HOLMGREN, ROBERT V
President
08/25/2000
Bond Amount
HOLMGREN, KARL V
Vice President
08/25/2000
39795
HOLMGREN, CHARLOTTE
Treasurer
08/25/2000
08/12/2010
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
4
AMERICAN STATES INS
39795
08/21/2006
Until Cancelled
$12,000.00
08/15 /2006
3
ACCREDITED SURETY
&CAS CO
10026079
08/21/2004
Until Cancelled
08/21/2006
$12,000.0008/18
/2004
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
12
WESTERN
HERITAGE INS
CO
SCP0817531
09/04/2010
09/04/2011
$1,000,000.00
08 /30/2010
11
WESTERN
HERITAGE INS
CO
SCP0765694
09/04/2009
09/04/2010
$1,000,000.0009
/01/2009
10
WESTERN
HERITAGE INS
CO
SCP0717081
09/04/2008
09/04/2009
$1,000,000.00
09/04/2008
9
WESTERN
HERITAGE INS
CO
SCP0670575
09/04/2007
09/04/2008
$1,000,000.00
08/30/2007
https://fortress.wa.gov/lni/bbip/Print.aspx
06/30/2011
`3
6'- 0'X4'- O'SLIDER
6'- 0'X4'- O'SLIDER 6'- 0'X6'- 8'GLASS DOOR
1
#2 DE 4'X10' HEADER #2 DF 4•X10' HEADER #2 DF 4'X10' HEADER
pDT : CA-r p-0/2, keltAole
PiciSINC7 ` SNO j G i I �ia77Nt`,
rU -6161.3c-11,7.- R Pipitiv Of MSni96
1-10 -1. Ca -p w,rr ,14 P S : c u), 714 N
0)144 07 - 1,1_.. (oa o 6D4673r4 j:-'
u 9 / QS
l dome
ri ,L19p 1 i M) 1/4/2.0/&. Pik:m
77 DitJ Du612.- ej tsr/N 6
/j fMipr /It S•lDirn
t,ts 6rugefiJ u0-aD 0 P
n-ti-I bs- 4 I OYISti)C 54/m4,
er krbiu - Ctihu 6
SCOPE OF WORK
Zc'
1-4 p,T,4
A °
44aoo I
4t4 30"14
tO
E-4 ist4 ‘1° '441
I 1
co o
ttmsql cc g•D"
REPLACE 2 WINDOWS
AND 1 GLASS DOOR
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 4 2011
+pL
City of Tukwila
BUILDING DIVISION
FILE COPY
Permit No., 1)%14 s9 ,
Pl r review approval is subject to errors and omissions.
pia! of construction documents does not authorize
4Aation of any adopted code or ordinance. Receipt
o approved Field Copy and condition is acknowledged:
By r v 1
Date: (e/ �'/,ii
City Of Tukwila
BUILDING DIVISION
SCALE 1 /4" 1'--O"
DRAWN
AL JOHNSTON
NO CHANGE IN FOOTPRINT
■r, °1 E PERMIT
4nU1ED FOR:
echanicai
electrical
'i nibing
i as Piping
City of Tukwila
PIA "SING DIVISION
DATE
4/22/2011
SCALE
1/4" = 1' -0"
REVISIONS
No changes shall be made to the scope
of cork without prior approval of
Tukwila Building Division.
T .: ions will require a new plan submittal
fnay ir,:;iude additional plan roview
PLANNING APPROVED .
No changes can be made to these
plans without approval from the
Planning Division of DCD
,16Ff4 4"
Approved By: ''Gil
Date:
SHEET
RECEIVED
JUN 02 2011
PERMIT CENTER
z
BY:
DESCRIPTION!
w
Q
A
H
V)
H
W
`3
6'- 0'X4'- O'SLIDER
6'- 0'X4'- O'SLIDER 6'- 0'X6'- 8'GLASS DOOR
1
#2 DE 4'X10' HEADER #2 DF 4•X10' HEADER #2 DF 4'X10' HEADER
pDT : CA-r p-0/2, keltAole
PiciSINC7 ` SNO j G i I �ia77Nt`,
rU -6161.3c-11,7.- R Pipitiv Of MSni96
1-10 -1. Ca -p w,rr ,14 P S : c u), 714 N
0)144 07 - 1,1_.. (oa o 6D4673r4 j:-'
u 9 / QS
l dome
ri ,L19p 1 i M) 1/4/2.0/&. Pik:m
77 DitJ Du612.- ej tsr/N 6
/j fMipr /It S•lDirn
t,ts 6rugefiJ u0-aD 0 P
n-ti-I bs- 4 I OYISti)C 54/m4,
er krbiu - Ctihu 6
SCOPE OF WORK
Zc'
1-4 p,T,4
A °
44aoo I
4t4 30"14
tO
E-4 ist4 ‘1° '441
I 1
co o
ttmsql cc g•D"
REPLACE 2 WINDOWS
AND 1 GLASS DOOR
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 4 2011
+pL
City of Tukwila
BUILDING DIVISION
FILE COPY
Permit No., 1)%14 s9 ,
Pl r review approval is subject to errors and omissions.
pia! of construction documents does not authorize
4Aation of any adopted code or ordinance. Receipt
o approved Field Copy and condition is acknowledged:
By r v 1
Date: (e/ �'/,ii
City Of Tukwila
BUILDING DIVISION
SCALE 1 /4" 1'--O"
DRAWN
AL JOHNSTON
NO CHANGE IN FOOTPRINT
■r, °1 E PERMIT
4nU1ED FOR:
echanicai
electrical
'i nibing
i as Piping
City of Tukwila
PIA "SING DIVISION
DATE
4/22/2011
SCALE
1/4" = 1' -0"
REVISIONS
No changes shall be made to the scope
of cork without prior approval of
Tukwila Building Division.
T .: ions will require a new plan submittal
fnay ir,:;iude additional plan roview
PLANNING APPROVED .
No changes can be made to these
plans without approval from the
Planning Division of DCD
,16Ff4 4"
Approved By: ''Gil
Date:
SHEET
RECEIVED
JUN 02 2011
PERMIT CENTER
icci
\
5,
‘
\
-Fe \
\ i;
\
W
1
A
•
l-4
PROPOSED GLASS SLIDING DOOR
Zc/D
C/) Z p � ceD
en Zd4CC•
Em4 r4 1141
z �n 1:1
I-, co ptil I
itc
<C tO 1-4 C'"'J 4.4
PROPOSED WINDOW
PROPOSED WINDOW
EXISTING FLOOR JOISTS
EXISTING DOOR
EXISTING WINDOW
EXISTING WINDOW
FILE COPY
Permit No..
Pups? review approval is subject to errors and omissions.
1.p?r/al of construction documents does not authorize
violation of any adopted code or ordinance. Receipt
(;_. approved Field Copy and conditions is acknowledged:
By r
Date: -
City Of Thkwila
BUILDING DIVISION
SCALE 114" = l'-0"
chances shall be made to the scope
cf work Without prior approval of tae
1Lik'•Jvila Building Division.
;•,w,y�V 9 sion.
� iO,fs will require a new plan submittal
ad may include additional plan review fees.
REVIEWED FOR .
CODE COMPLIANCE
APPROVED
JUN 2 4 2011
DRAWN
AL JOHNSTON
PLANNING APPROVED .
No changes can be made. to these
plans without approval from the
Planning Division of DCD
I� Approved By:
I. Date:
DATE
4/22/2011
SCALE
1/4' = 1' -0"
SHEET
\
5,
‘
\
-Fe \
\ i;
\
PROPOSED WINDOW
PROPOSED WINDOW
EXISTING FLOOR JOISTS
EXISTING DOOR
EXISTING WINDOW
EXISTING WINDOW
FILE COPY
Permit No..
Pups? review approval is subject to errors and omissions.
1.p?r/al of construction documents does not authorize
violation of any adopted code or ordinance. Receipt
(;_. approved Field Copy and conditions is acknowledged:
By r
Date: -
City Of Thkwila
BUILDING DIVISION
SCALE 114" = l'-0"
chances shall be made to the scope
cf work Without prior approval of tae
1Lik'•Jvila Building Division.
;•,w,y�V 9 sion.
� iO,fs will require a new plan submittal
ad may include additional plan review fees.
REVIEWED FOR .
CODE COMPLIANCE
APPROVED
JUN 2 4 2011
DRAWN
AL JOHNSTON
PLANNING APPROVED .
No changes can be made. to these
plans without approval from the
Planning Division of DCD
I� Approved By:
I. Date:
DATE
4/22/2011
SCALE
1/4' = 1' -0"
SHEET
Aq
DESCRIPTION:
L+J
H
4
A
#2 DF 4 "X10" HEADER
#2 DF 4 "X10 HEADER
REPLACED WINDOW
#2 DF 4 "X10" HEADER
REPLACED GLASS
SLIDING DOOR
2'X6' STUD WALL
R -21 INSULATION
7/17' OSB SHEATHING
W
O
z
0
LNA-
Z 1-1
LCD GYD
cn
4=4 eltti
In CO 0
v-i In to
›-.1%
co 44 I
o
'STING FLDOR JOISTS
EXISTING HEADER
EXISTING WINDOW
EXISTING
DOOR
EXISTING
SCALE 1 /2" = 1' — 0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 2 4 2011
DRAWN
AL JOHNSTON
DATE
4/22/2011.
SCALE
1/4' = 1' -0"