Loading...
HomeMy WebLinkAboutPermit D11-170 - KHUU RESIDENCE - ADDITIONKHUU ADDITION 13336 35 AV S D11 -170 City oPfukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7358600230 Address: 13336 35 AV S TUKW Suite No: Project Name: KHUU ADDITION DEVELOPMENT PERMIT Permit Number: D11 -170 Issue Date: 12/14/2011 Permit Expires On: 06/11/2012 Owner: Name: KHUU SANG Q Address: 13336 35TH AVE S , TUKWILA WA 98168 Contact Person: Name: SANG KHUU Address: 13336 35 AV S , TUKWILA WA 98198 Phone: 206 351 -8700 Contractor: Name: OWNER AFFIDAVIT - SANG KHUU Phone: Address: , Contractor License No: Expiration Date: DESCRIPTION OF WORK: ADDITION WHICH CONSISTS OF A FAMILY ROOM, A KITCHEN, A BEDROOM W/NEW FULL BATH, AND A COVERED DECK TO THE EXISTING HOUSE. (496 SF 1ST FLOOR ADDITION, 276 SF 2ND FLOOR ADDITION, AND 310 SF COVERED DECK.) Value of Construction: $99,851.08 Fees Collected: $2,433.96 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 22 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -170 Printed: 12 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: 1)—.41141 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. ++ JJ Signature: 5a to l - ''�� Date: Z l ) l ( � ( Print Name: 566 ,�Q IcLitAL This permit shall become n l and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 5: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. doc: IBC -7/10 D11 -170 Printed: 12 -14 -2011 7: Notify the City of Tukwila Building Divisio or to placing any concrete. This procedure. addition to any requirements for special inspection. 8: All wood to remain in placed concrete shall be treated wood. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 13: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 14: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: ** *FIRE DEPARTMENT CONDITIONS * ** 19: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 20: Adequate ground ladder access to rescue windows shall be provided. Landscape a flat, 12' deep by 4' wide area below each required rescue window. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D11-170 Printed: 12 -14 -2011 CITY OF TUK•A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Building Pe No. Di / /70 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. For o f ice use on Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION d King Co Assessor's Tax No.: 7 3 3 0 0 2 3 0 Site Address: I)) 5 3% 3 5 T AVE 5 D 6 S Suite Number: Tenant Name: Property Owners Name: Mailing Address: ! '7 )') G ')? 5rth P , S to Sol {I ut Floor: New Tenant: ❑ Yes .. No w pc- City '1, 1.6% state Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Saul tG\ ttUt Mailing Address: 3s`fti Ave. S , 4kAJI k E -Mail Address: Day Telephone: w � City Fax Number: �v 1 -'-10o lig State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: State Zip E -Mail Address: ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H: \Applications\Fonns- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: May 2011 bh Page 1of6 BUILDING PERMIT INFORMATIO to 206- 431 -3670 • Valuation of Project (contractor's bid price): $_ Scope of Work (please provide detailed information) f. Tv b lt_ 1Ic] — y\ 1� r u o w1� Gl k; +c hL f 6 Existing Building Valuation: $ 4 In act C(1 4-i oh w 1'1k`C' (.0115i-&' 19,e,4 roovVl w/ 171.t.. ■) 4U ) ba +11 k0 (AS-P ► s —n s� Flo v .Q. L&\ have, 4 P A5 &.Viol Vo? : Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: May 2011 bh Page 2 of 6 Existing Interior Remodel Addition to Existing ure New Type of Construction per IBC Type of Occupancy per IBCC 1st Floor %61USA �Sttruct 4ar6S� 7(,6s `(. �✓ rd Floor / /t o �P l q 10 S V 6 Vi' 3`d Floor Floors 1 thru 1 `+ z > I -7 0C c� 2 O�S¢ 2. Basement Accessory Structure* Attached Garage �- - U 4 4 0'¢ VII Detached Garage Attached Carport Detached Carport Covered Deck I O S 3 I o 5' U e-, (A. Uncovered Deck q PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: May 2011 bh Page 2 of 6 IDate Application Accepted: PERMIT APPLICATION NOTES — Amble to all permits in this application • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing, Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: S6 Print Name: 5-an K V1 yl lil Mailing Address: 1 Date: �, //i//J Day Telephone: c O 6 5 S I — 7 V v City State Zip Date Application Expires: ia- /I Staff Initials: A A) H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: May 2011 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7358600230 Address: 13336 35 AV S TUKW Suite No: Applicant: KHUU ADDITION RECEIPT Permit Number: D11 -170 Status: ISSUED Applied Date: 06/16/2011 Issue Date: 12/14/2011 Receipt No.: R13 -01147 Payment Amount: $63.00 Initials: LAW Payment Date: 03/27/2013 03:39 PM User ID: 1632 Balance: $0.00 Payee: KHIET N NGUYEN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 153699 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts BUILDING INVESTIGATION 000.322.800 63.00 Total: $63.00 doc: Receiot -06 Printed: 03 -27 -2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7358600230 Address: 13336 35 AV S TUKW Suite No: Applicant: KHUU ADDITION RECEIPT Permit Number: D11 -170 Status: APPROVED Applied Date: 06/16/2011 Issue Date: Receipt No.: R11 -02698 Initials: User ID: JEM 1165 Payment Amount: $1,476.90 Payment Date: 12/12/2011 11:40 AM Balance: $0.00 Payee: SANG QUOC KHUU TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1130 1,476.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,476.90 1,472.40 4.50 doc: Receiot -06 Printed: 12 -12 -2011 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7358600230 Address: 13336 35 AV S TUKW Suite No: Applicant: KHUU RESIDENCE RECEIPT Permit Number: D11 -170 Status: PENDING Applied Date: 06/16/2011 Issue Date: Receipt No.: R11 -01221 Initials: User ID: Payee: LAW 1632 Payment Amount: $957.06 Payment Date: 06/16/2011 09:55 AM Balance: $1,476.90 SANG QUOC KHUU TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1124 957.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - RES 000.345.830 957.06 Total: $957.06 doc: Receiot -06 Printed: 06 -16 -2011 INSPECTION RECORD Retain a copy with permit INSPECTI0 NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 i7�1 -1'�1a Proj R kiv abbr. too Type of Inspection: --,1 Al— 13., . t to , 46 Address: LG JJ3 3 3.) A VM Date Call Nl e 4 l___ Special Instructions: / Date Wanted: t.m i o �Z � ^ /3 p.m. Requester: Phone No(io _ a,./.1 _..4q 3 Q Approved per applicable codes. L n J Corrections required prior to approval. COMMENTS: P rd-i-A`IT C a pt � P 1 LeE' Iinspe Dat7:40 n REINSPECTION FEE REQUIIfED rsr to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 �. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D�.t -l�io Project: i4-117.4 /I ADDCTION) Type of Inspection: r--INNAL, Addres 133( 3`5 AUC. Date Called: Special Instructions: E,p ALti 01455t -0 I Date Wanted:. a.m — , 13 p.m. Requester: Phone No 'CG,_ 9L I— Lc -I3C.) ElApproved per applicable codes. O Corrections required prior to approhi. I COMMENTS: I) ill CO -* NIA 1— NFEbtt " J E Ieit -f ;@ R ( a'1m 1 rf ec.P , - AWLi -Ceti' kJ le- fn:4 -$ SPECTION FEE REQUI at 6300 Southcenter Bt ED. Prior to yd. Suite 100. IDat xt inspection. fee must be all to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. G CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 0 Project � v � Type of InsPcQn: ` J Address: rt^ 1333 6 5 r' U Date Called: . . Special Instructions: Date Wanted:. y -1. P.m. Requester: Pho No' l : , _fie 2 -54'7a ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: pk- p - (.0J Q X -- ! -F"ef tito\Pi/Nti 1 -1 $ c 4-' S kg-a\ )0 e.1 -r b vi,pker 0' . e..1 Q S 3 4 I+ c QS b (' L,c ,AXI- D 3 17■ AID 3J e i j S . t/ A \ 1\3 IIJ M - u. `A ' 90 r"---. ■ . Inspecto\___` Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee .must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule mein pection. • • • INSPECTION RECORD Retain a copy with permit INSPECTIO N0. PERMIT N0. Dij —190 CITY OF TUKWILA BUILDING DIVISION Gd 6300-Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permilnspection Request Line (206) 431 -2451 111•• Project ' ; u A�r.i N'r Typ f Inspe iontc - A : Address: R"% Date Called: Special Instructions: • Date Wanted -S-13 p.m. Requester: _ Phone No:(w &/d 2- -S4T70 Approved per applicable codes. O Corrections required prior to approval. COMMENTS: 0 ICC... .\.fit) (A- -- I.) it- d 4-3S ((,ps tv r7JS e n4 J - 2-. ..6 I-1 Lou 04 GJei�-- , vervd �1d �c,< ,Ara ? t-1-`` `` o J -tr r 0 'rL 'rkerr- 3 u 4 O F 11e o: 044 0 -- ri63 r 17-/ j-.4 . )/! 6 t-- c n" rdu :.X 4-,--f'-‘ , Insp ;(tor: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. An 1 Date 4*-8' INSPECTION NO. INSPECTION RECORD Retain a copy with permit 311- MO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 t,._. Pro�ec;KU J p Aot); t :o4 Type o nspection: rpcm,A6 Address. 5 33 co 'f't. 3� avt Date Called: £ s e J ftreef Special Instructions: Date Wanted: a.m. Requester: Phong NA./ ...s.„02...,....4 9 d Approved per applicable codes. Corrections required prior to approval. 8 COMMENTS: — G � L IJ LITe (■ pf0J ous NA/V.1A4 . •r-e Aki i% e or t- P C7' 4/4- S £ s e J ftreef re - itt, e Q J (e Inspec or: — G � a / % y Date/1 , 2 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 2 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • 1 � • .titii•'" 2II110 Prok:ii ULL /I AD 7 Type Inspections , Ad r ss co 15 i ‘.." 1 J , 14. 7 ..s- v � jI br /. f /4/2,1, (/ Date ailed: ' VL a S 1-- ,-1..-, ,,,-i----,1:- (-.N, Special Instructions: V D fs...4 _ Q C. 4 /h t. aye i / Date Wanted:— , a.m. Requester: 5-- p e-e. id. de,-(.4 4// ;S._. hone No: 7,--S1 70 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ✓ /) LAI 1 X Olean el ._ aline, 2 , .it,./.i✓t , i" /.b) /4, ri lj/ ... c /pi 1--. L6/ c 2-) 5u).2„eiedi,se 5 ,-,, - it-7 --,--os5e-z- ‘.." 1 J , 14. 7 ..s- v � jI br /. f /4/2,1, (/ - `,'7 k --1 '/ 2/3 " ' to 91- l 1_,4 / P ' VL a S 1-- ,-1..-, ,,,-i----,1:- (-.N, / s 49 V) 77-,-)-2.-e,4 //A/ -4-, 4e, 4.19 (54 Al, I.D0 kllalil' 5 ',rip fi (.. j--- cp'a l i S' J 1 5-- p e-e. id. de,-(.4 4// ;S._. L. //:-1/ 4 , f 1A / V 'l. Inspector: Date: 3"2.. )3 REINSPECTION FEE1REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 630 INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. y CITY OF TUKWILA BUILDING DIVISION 0 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pro ecG 1 KR-uu M T oij Type rinspection: i-rAM.. A ..* - 0 A 1 clE.S -- —�` t Alit/ - I d'{0/A'1. l -eijr / 7' t'. Address: 3 J A4 r T'� Date Called: %D G.,d Mere Rre L t -ru in 04,1 E 7-te 6.fA-LJL_S 3) T" , (t A-11 14 1) (.e f 9 ¢" fit...' c' MAY �o Special Instructions: (0X0 --- tc fl < 4$ `� LJ Date Wanted• ( ' l.-b 4-t Dje jP - i r` L *d a.m. Requester: Phone No: 4 02. --r —5 !'7C ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ..* - 0 A 1 clE.S -- —�` t Alit/ - I d'{0/A'1. l -eijr / 7' t'. {/e''\ %D G.,d Mere Rre L t -ru in 04,1 E 7-te 6.fA-LJL_S 3) T" , (t A-11 14 1) (.e f 9 ¢" fit...' c' MAY 4 ff2 •.( e.-Off i'ra A/ ( ' l.-b 4-t Dje jP - i r` L *d c} r ! 6) 60A,tpP 4 S 6rl /co 'LA 1„),\. . .atti 7-7 Si.3 Date: INSPECTION FEE REQUIRED. Prior to next inspection. fee musibe• • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection rAmPtf: , ) ' Ate t /A3. 1-W ow( #5. INSPECTION RECORD Retain a copy with permit " PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 fL INSPECTION NO. Proj�t�-t t t�i°1-JO /08 i . JA To InspectioQ: Type r, -a/k., A6 . Address: (3134 3L A. Date Called: • Special Instructions: 065 ns/4_ ()t* Date Wante T-f 3 .'� P.m. Req uester: P %nom 1 -4 30 JApproved per applicable codes. Corrections required prior to approval. COMMENTS: potO: Ay- 04 Ab . down -TD �()u )X't.p\ .J �r „. 1\ .(.e -4 re lit o d Ale E 1Date(4 - 13 n REINSPECTION FEE REQUIRED. Prior to next inspection!fee•must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule: reinspection. • • INSPECTION RECORD Retain a copy with permit I (10 INSPECTION NO. PERMIT•N0. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 11,2_,_ (206) 431 3670 Permit Inspection Request Line (206) 431 -2451 Pr a t: 0J , 0- 0A Type • of Inspection: p �iNJOEr d Ad're?ss 3 (c) 3- , , ` r r r Date Called: Special Instructions: Date Wanted:t. d 22-n / '� a.m. ) m. Requester: -15Wo-Fle No: 2.40 (o ---.EM t - q30 Approved per applicable codes. EJCorrections required prior to approval. COMMENTS: Inspetor: itic) Date, ..� z % . n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670' Permit Inspection Request Line (206) 431 -2451 Pr ject: Jc� A»: T,�t�a/ Type of Inspection: k )1�I0 .k 1 c7 . Address: 1 331({) ...."-r` 35L p A ^� o �.J 1r X 3 ' r 4 it , i„ r Date Called: Special Instructions: 1 ', --T'-z) rMz AN 4 3 Cr"- ' Date Wanted: 1 1 ,.- f '�.rn 1 4 -C .�-. - P.M. Requester: Phone No: —841y -461.6 jJApproved per applicable codes. Corrections required prior to approval. .1 COMMENTS: p A ^� o �.J 1r X 3 ' r 4 it , i„ r --T'-z) rMz AN 4 3 Cr"- ' f- ) A o n o 4 r l/ _ ' MY/ G Ate; if 4q ' p i 9 it D 0 -1, (11C.- (IM ( SkPer' it--- _ l Ins sector: Date: • ri REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • -ru INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 17.. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 .0 11 -/'Q. Pro'ec t� A-0 8: 1 I ` � � Typ((e��of��Inspection: IC U r ..s k e ''�J� I t-i , . i & Address: 11 1 133 0 3 T`4 J Date Called: . Special Instructions: Zr Date Wanted:. ,- ' .- p.m. Requester: `I A f/� 1 ' Jl / ..�f 1 V f1 ' / Mlle ∎. y-ir+' Wt... Phone No: Approved per applicable codes. Corrections required prior to approval: 7 COMMENTS: :. 1-(-04- � -ozk Sk 'fl�. rTJe ,, $.1/4J -p -,,f u.J U-• 2 I A-,Alf . T/' ..S AI) Litt— c ')C;3 S'N'✓L' Jr� • L e. r e ,s ue*` H �iQ Ai S ‘, kt-o.s o rt RA-6444 e ', t., p r ,.J_e- A,J or 3P - r.A-n'.3A. 43.F. . jpoit I i,JJ _S 2. as,-r -f� J crli INSPECTION RECORD Retain a copy with permit I ' 1 r ( r� 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,, (206) 431 -3670• Permit Inspection Request Line (206) 431 -2451 Project C uJ :)0,r o,v Type Inspection: 4(,l,) -- I -� Address: 7-i- 1333 3S -AV? - Date Called: M k K,' •.r d \ :-Y 7� t: ' 4 Ce.A41 ' -, - ,�A5 U Iu(e -Tcf e„ . • . f_c a) _c. , ,4 J'-4' JCS • ...., Special • I Instructions: , ��R O� • V / Date Wanted:. r y ` terHoJt . "equester: hone No: '� © 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS d e e d . 1�: ` r - ; a A C.tP1k4 p of 4-enc . p: e.2S g f 't e Ad:; S4 .sL i: 3\ , n- te:. _ J /4 Ai - c I .l g...I)o f /G pit & i 5 p) A Roy, ^ r' M k K,' •.r d \ :-Y 7� t: ' 4 Ce.A41 ' -, - ,�A5 U Iu(e -Tcf e„ . • . f_c a) _c. , ,4 J'-4' JCS • ,31" so ,�-- AA tds - c_ (�. S eL 4 /c -D F .St e't . (-or v / •-(kCJ" Ro or re (14,6,e All. f f . � _. . a?' a, ;A `a: . 1) S e 3 x "3 ` PIA ,r ` terHoJt St d( A vno Inspect der r7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be..' paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule:r•einspectibn: 44- INSPECTION NO. INSPECTION RECORD Retain a copy with permit l i - (170 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Ile- (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Projec : K, i �� �a�� � Type f Inspection: �- t T V Li Aa .t , v 4 Address: 13- (6 _ .— - i Date Called: +„' v J L u-e is r .. i k i/i k Aez -L„s.s ? Special Instructions: (-L?) 1re., -z"Z.O vJO d ,kf-r-D Ae_. Date Wanted: ,.. Q.m. Requester: __^ Phone N o: --35( ! -706 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: cse to NoW e IL tfre) Ai( .-i er;0k .f-n :n &S AJvr -I) 310 -,._ - - , y 0 . t viLu A-r P c. r l Ue +„' v J L u-e is r .. i k i/i k Aez -L„s.s ? (-L?) 1re., -z"Z.O vJO d ,kf-r-D Ae_. vcQ ►, - (tJ U '\o LJ.It Ae \ Sig e' ` ef ran rft_ 144 etk ' a:ri ,r 1Z / P. /A rAA(.e e dAAn e . (1 r Li L : f tip Ar c iJ\ P-JM, 3 /).frc 4)- We(fSc 1``krou Ak f-I z,c) g. . • InspQ�or: ' n REINSPECTION FEE REQUIRED. P for to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. S �! INSPECTION RECORD Retain a copy with permit. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 W.. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 v PERMIT NO.c.,V7 Pro'ect� Q � � • � � a! � Type of Ipspe tit on: , h)13 (, A4. A re s: / 333 7I► 3S- AI 1-. Date Called: Special Instructions: .1 / �-, Date Wanted r I' l p m. / m. Requester: Phone No: _ '7,06) '��t f _�Q l V ppr• r applicaNe ad ctions required prior to approval. COMMENTS: iArrrt'd4 900 era MC_ a- 1,(L d rTh r: Datei 1 � Inspe ❑ REINSPECTION FEE REQUIRE or to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. _.�ti —�. - -- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 y. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 -110 Pro'ect: t(--Jos AO�D.�. a/ / Type of Inspection: .fibe, ( (A6, Ad ress: fG )�, .3 S `"Au, Date Called: Special ial Instructions: Date Wanted:. / '� — ��.p /�rrl, �z p.m. Requester: Phone No. 'Lo ZS — g--7 0 a ElApproved per applicable codes. orrections required prior to approval. COMMENTS: kieeD MA .i e c-A.1 rc t P A _ 0 IA co — Like AJ(700 Inspecto 1 — (( i ❑ REINSPECTION FEE RE4ll .Prior to next inspection. fee must be paid at 6300 Southcent r Blvd., Suite 100. Call to schedule reinspection. • I. . -y - - - • '+ ,. et L - - - -• 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Proje ff• / iNr hC9L! 4/c )1,011 Sprinklers: Type of Inspection: ACe- /fit / Address: 3 I � Suite #: ,�/ z�� �� � Contact Person: Special Instructions: Occupancy Type: . Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: Final - 4/1 o Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: . Inspector/ VMS-ti Date: "! /11 Hrs.: , $100.00 REIRSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Fin nce Department. Call to schedule a reinspection. Billing Address Attn: Address: City: Word /Inspection Record Form.Doc 1 Company Name: State: Zip: 6/11/10 T.F.D. Form F.P. 113 01 -02 -2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SANG KI-IUU 13336 35 AV S TUKWILA WA 98198 RE: Permit No. D11 -170 KHUU ADDITION 13336 35 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 02/05/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 02/05/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. DI 1 -170 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431 -3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 14, 2011 Sang Khuu 13336 35 Ave S Tukwila, WA 98198 RE: Request for Application Extension Application Numbers D11 -170 Khuu Addition —13336 35 Av S Dear Mr. Khuu, This letter is in response to your written request for extension to Permit Application Number D11-170. The Building Official has reviewed your letters and considered your request. It has been determined that the City of Tukwila will extend the permit application expiration date an additional 90 days, through March 12, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. D11 -170 W:\Permit Center\Extension Letters\Applications\2011\D11 -170 Application Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 November 28, 2011 City of Tukwila Department of Community Development RE: Permit Application No. D11 -170 Dear Sir, ne;oa9v_ NOV 3 0 20111 t ; ; ALL, '4' ouENT I would like to request for extension of my building application permit. Because there is few changes from my initial planning which I have to take it in consideration of cost and labor of my current project. I will have my revised drawings submitted before the original application deadline. I appreciate your help and I will try to get my building application approval in timely manner. Sincerely, Sang Khuu a g virtetei elft/t oiceide fl/0°11 f2o, 11-1121111 86- 11-111- C 11 -01 -2011 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SANG KHUU 13336 35 AV S TUKWILA WA 98198 RE: Permit Application No. D11 -170 KHUU ADDITION 13336 35 AV S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 06/16/2011, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 12/13/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician File: Permit File No. DI 1 -170 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • 8. In addition to smoke detectors, carbon monoxide detectors shall be required under the new codes. Combination smoke and CO detectors may be available. Show CO and smoke detectors on the plan. 9. Plans are typically drawn 'A" scale for better clarity and the site plan is 1/8" scale. Please provide plans that are clearly legible and drawn to a legible scale. Number all sheets. 10. Elevations and plan view references shall be identified as North, East, South, West rather than front, back, left and right. 11. Provide a specific detail for the deck plan that clearly specifies foundation or footings, post, deck materials, hardware and all other elements that go into construction of the deck. An elevation cross section shall be required to show framing, methods of attaching ledgers or other framing members to the existing building. For all plan details, DO NOT USE any handouts for your plans; those are only for your reference. 12. Specify location of attic and crawlspace access, new and existing. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. . • PLANNING DIVISION COMMENTS DATE: August 8, 2011 APPLICANT: Sang Khuu RE: D11-170 Khuu Addition ADDRESS: 13336 35th Ave S (parcel #735860 -0230) Please review the following comments listed below and submit your revisions accordingly. 1) Indicate on plan sheet 9 what the roof pitch of the addition area will be. Note that the minimum roof pitch requirement, per TMC 18.50.050 Single Family Dwelling Design Standards, is 5:12. 2) Aerial photos of the property show a structure in the back yard. Please show this structure on the site plan (Sheet 2), including the distance of this structure from the proposed addition and from property lines. Also notate on the site plan the square footage of this accessory structure. If you have any questions related to the comments above, Jaimie Reavis is the planner assigned to the file and can be reached at 206 - 431 -3659. Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Sang Khuu 13336 35 Av S Tukwila, WA 98168 RE: Correction Letter #1 Development Permit Application Number D11 -170 Khuu Addition —13336 35 Av S Dear Applicant, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Planning Departments. At this time the Fire and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Planning Department: Jaimie Reavis at 206 - 431 -3659 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. DI 1 -170 W:\Permit Center\ Correction Letters \2011\D11 -170 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: July 8, 2011 Project Name: Khuu Addition Permit #: D11 -170 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The addition of the second story does not clearly identify all roof and floor loads transferring down to the foundation nor are there any details to show how the different levels are tied together and tied down to the foundation. Unless it can be clearly and specifically detailed out to show all the prescriptive construction elements that meet the current 2009 International Building Codes, a structural engineer shall be required to provide the necessary details and engineering for this project. The plan shall have a detailed framing floor plan of each level. The plans shall show what is as -built or existing and then show and specify all that is new for each floor, roof and foundation. 2. In addition to item 1), elevation cross sections shall be required to provide details for framing specifying all methods of connections, framing members with their sizes, hardware specifications etc. Provide specific elevation framing cross sections to show all methods of construction. Cross sections shall specify wall size or thickness with insulation on exterior walls identified. Roof and floor details shall specify insulation as required. 3. Plan view shall specify braced walls and how the braced wall construction transfers down to the foundation. Connections shall be identified in the cross section details. 4. A cross section of the second floor shall be required to show sloping portions of the roof to indicate any sloping ceilings for determining headroom requirements and to provide a clear picture of the second story construction and how it all ties together. 5. Provide a floor plan for the foundation with elevation view for post piers and foundation construction. Specify size of footings and specify steel and hardware. 6. The plans provided only show new addition and do not clearly identify the new kitchen and bathrooms. All new construction or elements of the remodel shall be clearly identified and show the existing walls or rooms to be renovated or removed to make place for the new bathrooms and kitchen and any other portions of the renovations not indicated as applicable. 7. On the cover sheet specify code compliance, with current 2009 building codes and the Washington State Energy code. ��ILA.I.1, • f S =Ike§ Z City of Tukwila June 22, 2011 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Sang Khuu 13336 35 Av S Tukwila, WA 98168 RE: Incomplete Letter #1 Development Permit Application D11 -170 Khuu Addition —13336 35 Av S Dear Mr. Khuu, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 16, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Dave Larson at 206 431 -3678 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician Enclosures File: DI 1 -170 W:\Permit CenterUncomplete Letters \2011'D11 -170 Incomplete Ltr # 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Determination of Completeness Memo Date: June 21, 2011 Project Name: Khuu Addition Permit #: D11 -170 Plan Review: Dave Larson, Senior Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The second story bedroom addition does not appear to transfer floor and roof loads to the foundation. Please revise plan or provide an engineered design stamped by a structural engineer licensed in the State of Washington. 2. Provide a foundation plan for the deck and deck roof. 3. Please provide cross - sections that are relative to this project. The handouts you obtained at this office are examples and should not be used in your plans. Your cross - sections need to show how you're going to construct the addition. More than one cross - section may be necessary to completely show all framing members, framing connectors, insulation, sheeting' foundations etc. 4. Please show compliance with the Washington State Energy Code. 5. Please add smoke detectors to the plans. 6. Note that this is not a complete plan review and other corrections to the plans may be required after your application is accepted as complete. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PLAN VIEW /ROUTING SLIP ACTIVITY NUMBER: 011 -170 DATE: 12 -05 -11 PROJECT NAME: KHUU ADDITION SITE ADDRESS: 13336 35 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: ( /din 'Division Public Works Fire Prevention Structural JR .Y Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -06-11 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 01 -03-12 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only • ' CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 ,PE T • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -170 DATE: 07 -05 -11 PROJECT NAME: KHUU ADDITION SITE ADDRESS: 13336 35 AV S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPA'TME TS• di Public Works 11 tt Fire Prevention Structural n • 8 -8-11 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 14, Incomplete DUE DATE: 07-07-11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: 'Vej Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-04-11 Approved n Approved with Conditions ❑ Not Approved (attach comments) Nt Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only ^ ^ t0---1, CORRECTION LETTER MAILED: 1C�1 �-- Departments issued corrections: Bldg Fire ❑ Ping� I'Ltf tJ Staff Initials: Documents /routing slip.doc 2 -28 -02 ifERNi1i COORD COPY". PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -170 DATE: 06/16/11 PROJECT NAME: KHUU ADDITION SITE ADDRESS: 13336 35 AV 5 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENT: ottw Building Division Public Works • AVV\ Fire Prevention Structural f Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Kr DUE DATE: 06/21/11 Not Applicable Comments: Permit Center, Use Only INCOMPLETE LETTER MAILED: (12.)-)--- \ i LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: u(A( TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/19/11 Approved ❑ Approved with Conditions Not Approved (attach comments) Ti Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Pt° C 5-1 2 0 11 Plan Check/Permit Number: D11-170 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Khuu Addition Project Address: 13336 35 Av S Contact Person: ci 11.G) k VIM Vt Phone Number: Div '3 3 i.- '0 v 0 1 Summary of Revision: The rte- wi 11 be .n o 5-e,Co VVJ -� Lc.2O R cJ cA 7 o k1 gi5 e- 110. 1 �,v1Y1 -t • V' In/la 1Y\ -e � o o r q .. 1+616 5f. A l ! 1r�v 1'S r vv1 s w eAv'-c, 14(1 act I , S lan vv -k}la l (4ira„)411 + . tRIBCONED CITY a DEC 0 5 2011 Sheet Number(s): p I-eA S--e c {S c (d G l 1 Pr-e-VI'o ..$ 671 l l 5 , PERMIT CENTFk+ "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 714 11 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: D11-170 Project Name: Khuu Addition Project Address: 13336 35 Av S RECEIVED CITV OF TUKWILA IJUL 05 2011 PERMillVelifffia Contact Person: SGtitA J k \IAA '.4 Phone Number: _ 2(-2 C° 3'5-1 — Y , O° Summary of Revision: 1. (.v I S e -e .2vt•41 7 1- o !3 Pjt_107-0 W1 ciM 441 10 0 S'v.rw t \oo, cmili t- °04-- l n�45 T`-- 41442- .%fl 4a c.)vl . .)rov'4 - 4 ,, , e liloV1 . r c �� a vim( o� -ecic. ro 7 ) , P rc, v v - c c ( (Y'v i S - S-c p o v 1 S PIA---f a l r < rte- (a ti42 +c; +AA ‘‘S. rra3-tc+ • �� NA.) c.4, tn� ,� i� Yl C� t S vv^ i' 5 14-c d 4 S rrto ke- o(- e,4:e- c ites 1 tin /e Sheet Number(s): 3 14 1 (p) 7 1 ci i 1 1 a vL,� 14 . "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 02/05k Atti \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431 -3665 E -mail: tukplanaci.tukwila.wa.us • Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: - o STATE OF WASHINGTON) ) ss. COUNTY OF KING ) IN1Gr- a K4--/ u,u [please print name] , states as follows: 1. -I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requiremegt of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 17— , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Notary Public State of Washington WILLIAM H GREENE MY COMMISSION 201PIRES February Lgi.,v /<atL Owner /Owner'sijgent* Signed and sworn to before me this 13 4` day of a c, , 20 t . NOT AY PU ,IC in and for the State of Washington Residing at Name as commissioned: ) , County J°v.') /`ct4, My commission expires: �e 1) 07 18.27.090 Exemptions. The regition provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed chapter do not apply • by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. PROJECT DATA PROJECT ADDRESS: OCCUPANCY: NEW ADDITION AREA: NEW COVERED DECK: LOT AREA: OWNER: 13336 35TH AVE S TUKWILA, WA 98168 SINGLE FAMILY 496 SF 240 SF 6000 SF SANG KHUU 13336 35TH AVE S TUKWILA, WA 98168 206 - 351 -8700 SEP /RATE PERMIT REQUIRED FOR: erttebhanicat CQctricai &numbing Cods Piping Gf:y of Tukwila .U!LDiNO DIVISION c+1 g' • CONSTRUCTION TO COMPLY WITH THE 2009 EDITION OF THE I AND 200 ? WASHINGTON STATE ENERGY CODE. 9 Riverton ` 49''x. S 122nd S t� o . I erg, / it S134thSt t - --: 125th St ‘�„ --- \"--- Q� CY: VICINITY MAP S 1 31 et _s192nlI Tina $ I i s 135th Sl L ,1 IS 128th ?? -- \\, TON \ K"9 5138th St co: SHEET INDEX i REVISIONS No changes shah be made to the scope of work without prior approval of Tukwila Building Division. 1 I.:017:: R :tsivns will require a new plan submittal and may include additional plan review fees. 1. COVER SHEET 2. SITE PLAN 3. FOUNDATION PLAN 4. FOUNDATION AND FRAMING P 5. MAIN FLOOR PLAN 6. ROOF FRAMING PLAN 7. BUILDING CROSS - SECTION 8. FOUNDATION WALL DETAILS 9. BATH /KITCHEN ISOMETRIC PLU 10. BATHROOM PLUMBING PLAN 11. KITHCHEN PLUMBING PLAN 12. ELEVATION VIEW PLANNING APPROVED s..:. • No changes can be made. to these plans without approval from the Planning Division of DCD 4 4:4 Approved By: Date: FILE COPY Permit No., D 11- %`lQ PMar, rC flew approval is subject to erTors and omlsslons. of construction document does not authorize p of . y adopted code or ordinance. Receipt o; L.pproved Field Cop and cottons is acknowledged: By (Zk1L-_----- Date:, 12- z7// City Of 'Tiukwila BUILDING DIVISION SHEET NO. 1 'd'4 .7r CORRECTION bik 17 REVIEWED FO, CODE COMPINCE APPROVED DEC 0 9 2011 WIL City of Tukwila BUILDING DIVISION RECEIVE. DEC 05 2011 PERMITCENTEF 00 Z 'ON 133HS ,Ot =„ t :31VJS o eNrn N o 35TH AVE S 50' DRIVEWAY 22' N O EXISTING GARAGE EXISTING HOUSE .EX)S T rNCr OFCk TO 1)2E I PROPOSED NEW ADDITION PROPOSED NEW DECK S scT 50' 27' lo' 5'10 "3 22 f, 31' 14'8 "5 -- 4 /EXISTING FOUNDATION! EXIS11ING CRAWLSPACE ACCESS 8'3 0 (7) 241" SQ. x 10" THK. CONC. PAD VN /4x4 P.T. POST ABOVE NtW �CRAWLSPACE ACCESS(2'x3') CV N f " TYP. SdREENED FDN. VENTS NEW FOUNDATION 31' (4) 16" SQ. x 18 THK. CONC. FOOTING AND POST BASE SET IN CONC. 7� i SCALE: 1/4" = 1' } FOUNDATION PLAN SHEET NO. NEW FOUNDATION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION ECEWED DEC 05 2011 PERMIT CENTER 5'10 "3 b 2'2 31' 14'8 "5 — - 8'3 4 1 0 EXISTING FOUNDATICJCISTING CRAWLSPACE AICCESS 1 1 1 / METAL HANGERS TYP. — 1 i (7) 224" SQ. x 10" THK. CONC. PAD) W /4x4 P.T. POST ABC)VE 1 4x10 DF NO. BEAM 9 1 /2 "1TJI'S RIM JO ST 9 1/2" TJI'S @ 24" OI.C. W/ CROSS BRIDGING OR BLOCKING NE F011iDATION � —� ANEW ACC CRAWLSPACE SS(23 3') CV N TYP. SCREENED FDN. VENTS Cr.; 911/2" TJI'S RIM JOIST 4--- WOOD DECK (2x6 PT) - 9 1/2" TJI'S RIM JOIS METAL HANGERS TYP. 2x8 P.T. JOISTS @ 24" O.0 0) (4) 24" SQ. x 18 THK. • CONC. FOOTING AND POSIT BASE SET IN CONC. L1'6ti 7' 7' 23'11 31' ,4x10 PT BEAMS OVE 4x4 PT POSTS 7' 1'5 7'1 FOUNDATION AND FRAMING PLAN SCALE: 1/4" = 1' SHEET NO. 4 NEW FOUNDATION " CODE COMP' 9ANCE APPRO VED DEC 0 9 2011 City of Tukwila BUILDING D1ViS1ON ECEDVED DEC 05 2011 PERMIT CENTEF EXISTING FRONT PORCH S 'ON 133HS EXISTING LIVING ROOM EXISTING DINING ROOM 35' I I EXISTING GARAGE UP CO & SMOKE DETECTOR EXISTING BEARING WALL K) OLD KITCHEN BEING NEW CLOSET REMOVED _ J 4x12 DF HEADER IN PLACE FOR EXISTING WALL NEW KITCHEN [ 0 4'2 SKYLITE NEW NON ----BEARING WALL EXISTING BATH EXISTING LAUNDRY ROOM NEW CLOSET CO & SMOKE DETECTOR CONVERTING EXISTING FAMILY RM TO NEW MASTER BR NEW CLOSET - ) NEW BATH 4x12 DF HEADER IN PLACE FOR EXISTING WALL (0 JL NEW NON BEARING WALL NEW FAMILY ROOM CO & SMOKE DETECTOR NEW COVERED DECK MAIN FLOOR PLAN SCALE: 1/4" = 1' SHEET NO: 5 24' 0 NOTES: ROOF TRUSSES TO BE PRE - ENGINEERED & SHOP FABRICATED. BE INSTALLED & BRACED TO MANUFACTURER'S SPECIFICATIONS. 31' EXISTING EXISTING GABLE ROOFING BEARING WALL r BEARING WAL OD CD N (8) 8" SQ ROOF VENTS PREFABRICATED ENGINEEREDTRUSS @ 24in O.C. OVER NEW ADDITION 6x8 TYP. HEADERS OVER DOORS AND WINDOWS I t ATTIC ACCESS BEARING WR+LL CD CD 'CONT. ALUM. GUTTER TYP. 24' 31' ROOF FRAMING PLAN SHEET NO. 6 SCALE: 1/4" = 1' 7' O REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 05 2011 PERMIT CENTER 2x6 SHED DECK @24in ROOF O.C. /" TYP. OVER \ 4x10 HEADER @7FTO.C. BEARING OVER WALL 4x4 POSTS BEARING WR+LL CD CD 'CONT. ALUM. GUTTER TYP. 24' 31' ROOF FRAMING PLAN SHEET NO. 6 SCALE: 1/4" = 1' 7' O REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 05 2011 PERMIT CENTER STANDARD CONSTRUCTION ASSEMBLIES ROOF ASSEMBLY • ASPHAL SHINGLE ON 15# ROOFING FELT ON 34" PLYWOOD SHEATHING. • TRUSSES AT 24" O.C. • BLOWN -IN INSULATION. R— / • 34" DRYWALL AT CEILING. EXTERIOR WALL ASSEMBLY • 6" CEDAR LAP SIDING ON 15# BLDG PAPER, ON 34" PLYWOOD SHEATHING. • 2x6's AT 24" O.C. TO ALIGN WITH TRUSSES ABOVE). • R -21 FACED BAT!' INSULATION. • 34" DRYWALL FLOOR ASSEMBLY • LAMINATED FLOORING. • 1" T &G OSB SUBFLOORING (CREWS). • 934" TJI's AT 24" O.C. • POST AND BEAM SUPPORTS. • R -30 BATT INSULATION. • 4 MIL VAPOR BARRIER, LAP 12" AT SEAMS. 1. last' • \vaitts G am= t2- 1,100) Qn r �t k '�� c��'�� f qty � of `:�, 11 \;, o-`i aN•A 4Lt f l v./ evil est►�, tZeof +tn.sfeS E 1i INS H.-jL);i- -. + 1• ‘*►S S yvVt w re comet, 'c' GAPS TaiSZ RAt'.4t Tv E W AN)! T 1 O ru'4 t" 5/3 TZ6 t:7 ,3 , � SE�ioAi- ) 11,0MIKIfferlaNatelni r E\RST 1NG- Lx (. L� 1 bJ�1f10 4" SHEET NO. 7 • \ FxijTlNCr M∎L BUILDING CROSS - SECTION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 05 2011 PERMIT CENTER CONSTRUCTION NOTES TIC 1. CONSTRUCTION TO COMPLY WITH THE 2009 EDITION OF THEAND WA STATE ENERGY CODE. 2. MINIMUM NAILING REQUIREMENTS: ALL WOOD STUD WALL SHALL HAVE THE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 6" O.C. 3. ALL WOOD FRAMING SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF 2009 4. NAIL GYPSUM WALLBOARD TO ALL STUDS, TOP AND BOTTOM PLATES AND BLOCKING WITH 6d NAILS AS Z R.c, 5. BRACING. ALL EXTERIOR WALLS WITH HORIZ. LAP SIDING SHALL BE EFFECTIVELY AND CONTINOUSLY BRACED USING 34" PLYWOOD SHEATHING. 6. PROVIDING TEMPORARY BRACING FOR THE STRUCTURAL AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETE IN ACCORDING WITH THE PLANS. 7. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH. 8. ALL WOOD PLATES IN DIRECT CONTACT WITH CONCRETE SHALL BE PRESSURE - TREATED. LUMBER EXPOSED TO WEATHER SHALL BE CEDAR OR TREATED WITH APPROVED PRESERVATIVE. 9. DOOR/WINDOW GLASSES SHALL BE LOW -E DOUBLE PANES. 10. ATTACH TJI's AND /OR WOOD JOISTS TO FLUSH HEADERS AND BEAMS WITH SIMPSON METAL JOIST HANGERS TO SUIT THE JOIST SIZE. Q - .Way 1'yr• `// 7-31, 4 \ O �iti rj\ REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 9 2011 City of Tukwila BUILDING DIVISION vs. z 171: 1/ /�,V'V/ A ki �oo ec �''GyaJgo RECEIVE � a r DEC 05 2011 ►''" " ''')42 SHEET NO. 8 FOUNDATION WALL PERMITCENTER v� L t I - If 11:4' s ( ,' it V' it I' ' -/2 � BATHROOM ISOMETRIC PLUMBING PLAN VIEW SHEET NO: ei KITCHEN ISOMETRIC PLUMBING PLAN VIEW SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED DEC 05 2011 PERMIT CENTER 3 `'T U BATHROOM PLUMBING PLAN SHEET NO: 10 0 0 SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED DEC 05 2011 PERMIT CENTER O J KITCHEN PLUMBING PLAN SHEET NO: I1 c o SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVE DEC 05 2011 PERMIT CENTER EXISTING HOUSE NEW ADDITION MIN DECK NORTH VIEW (LEFT) NEW DECK NEW ON EXISTING NOUSE SOUTH VIEW (RIGHT) ELEVATION VIEW SHEET NO. 12 EAST VIEW (FRONT) REVEWED FOR CODE COMPLIANCE APPROVED ED DEC 0 9 2011 City of Tukwila BUILDING DIVISION WEST VIEW (REAR) RECEIVED DEC 05 2011 PERMIT CENTER